Home

om_MasterCool Residential manual 110498-2.indd

image

Contents

1. 110351 110351 110351 110351 26 Receptacle Motor Toma De Corriente Del Motor cssssecseessessesseesseesteeseeeseesneeseeees 110393 110393 110393 110393 27 Receptacle Pump Toma De Corriente De La Bomba ssssssssssssssssiriririrsrerssssssssssssss 110361 110361 110361 110361 28 Media Shield Right Protector Para El Medio Evaporativo Direcho 281043 002 281045 002 281044 002 281046 002 29 Media Shield Left Protector Para El Medio Evaporativo Izquierdo 281043 001 281045 001 281044 001 281046 001 30 Water Distributor Housing Caja Del Distribuidor De Agua 281038 001 281033 001 281038 001 281033 001 31 Water Distributor Tube Tubo Del Distribuidor De Agua 3D 23 3D 23 3D 23 3D 23 32 Evaporative Media Set Conjunto De Medio Evaporativo sess 310117 001 310118 001 310117 002 310118 002 33 Distributor Filter Pad Filtro Del Distribuidor w 110120 110120 110120 110120 34 Water Reservoir Bandeja Acumuladora De Agua 281041 001 281042 001 281041 001 281042 001 35 Tube Water Delivery Tubo De Agua iimsimimsemanananaanaanaanaanaanaanaananne 310716 310716 310716 310716 36 Over Flow Assembly Montaje De DeSagtie cesses 110610 110610 110610 110610 37 Float Valve PloladO usina css FL C FL C FL C FL C 38 Float Shield Salpicadero Del Flotador immsimanenesanmanan
2. 7 INSTALLATION 8 OPERATION MANUAL SINGLE INLET EVAPORATIVE COOLERS Circle the model of your cooler and record the serial number Encierrre con un circulo el modelo de su enfriador y escribe el n mero de s rie Date of Purchase Fecha de compra ADA51 ADA5112 ADA71 ADA7112 ASA51 ASA5112 ASA71 ASA7112 AUA51 AUA5112 AUA71 AUA7112 Serial Number N mero de s rie READ CAREFULLY ALL OF THIS MANUAL BEFORE INSTALLING THE UNIT READ AND SAVE THESE INSTRUCTIONS SAFETY RULES TABLE OF CONTENTS Safety Instructions reennnrnnnrn 1 How Evaporative Coolers Work 1 1 Install ici lite 2 Opera roster 5 Air Balancing Methods merennena 5 3 Maintenance 6 Specification TableS oococcocoonnonnoemorrrrarro T 4 TroublesNOOLNG 14501130 date nta 7 Limited Warranty iic cch iessecpeuiieediicensedsaeeectiees teenies 8 5 Tabla de Contenido En Espa ol 9 Illustrated Parts List Ilustrado Lista de Piezas de Repuesto English Espa ol iii ia 17 Garant a Limitada sissies ieie aaea 24 HOW EVAPORATIVE COOLERS WORK Evaporative cooling is nature s way of cooling When air is moved over a wet surface water is evaporated and heat is absorbed When stepping out of swimming pool with the wind blowing evaporative cooling makes you feel cool even though the air may be warm This unit works on the same pri
3. fi si 310716 310716 310716 310716 36 Over Flow Assembly Montaje De Desagle iooconicinnicimmmmmmerermrss 110610 110610 110610 110610 37 Float Valve Flotador c sissscccassscesssesetisetsstdectstactisteaiciein didas FL C FL C FL C FL C 38 Float Shield Salpicadero Del Flotador mmsimannesanmananvaanmananesanmananeai 281006 281006 281006 281006 39 Pump Bomba ri aia 110429 110429 110429 110429 41 Pump Mount Montura De La Bomba scsscssseccsessssseesssesesssesssnseessesessnesessneeesnneeeeees 218002 012 218002 012 218002 012 218002 012 42 Pump Retainer Sujetador De La Bombad ssssssssssssesssesssesseessessnecsnesseeseesnssneeeneesneess 110714 110714 110714 110714 43 Anti Flattening Coil Espiral Protectora ccssssssssssecsessseesecsesssessnsssnssssesesesesenesenessneees 110847 110847 110847 110847 44 Bleed OffKit Equipo De Purga s sssossrrssssseeserrssssorrerresssererenrnssonrerrnnnsennerrnsnenererres 310586 310586 310586 310586 See the motor specification table Motor sold separately Vea la tabla de especificaciones del motor Motores se vende por separado 230V motor cord is optional and not supplied with cooler Cable el ctrico del motor de 230V es opcional y no se env a con el enfridor NOTE Standard hardware items may be purchased from your local hardware store NOTA Art culos de uso corriente pueden comprarse en la ferreter a de su localid
4. No N Description Descripci n ASA51 ASA5112 ASA71 ASA7112 Top Cabinet Tapa De La Caja si A 222130 070 222130 070 222140 053 222140 053 Top Access Panel Panel Superior De Acceso i 222130 074 222130 075 222130 074 222130 075 Bottom Blower Section Base De La Secci n De La Rueda 322130 069 322130 069 322140 052 322140 052 Bottom Wet Module Base De La Secci n De Agua mmnmsmanenesnns 222130 072 222130 073 222130 072 222130 073 Front Panel Panel Del Frente anidre oa 322130 077 322130 077 322140 056 322140 056 Inspection Panel 2 req Panel De Inspecci n 2 req eesecseesseeseesseesneeenieeseeees 224130 002 224130 002 224140 002 2241 40 002 Center Post Right Poste Central Derecho ou essesssesseessteeseeesessseesnieesesesneesneeenees 222130 062 222130 062 222140 045 222140 045 Center Post Left Poste Central lzGuierdo smannmsenmanamnamananenanvananeaa 222130 063 222130 063 222140 046 222140 046 Back Post Right Poste Trasero Derecho mmrminmennnsenaeeaenmaamaaneenena 222130 064 222130 066 222140 047 222140 049 Back Post Left Poste Trasero lzguierdo mimsermsemananmsamananesanmananeaane 222130 065 222130 067 222140 048 222140 050 Blower Housing Caja De La Rueda a5 si 824130 203 324130 203 324140 203 324140 203 Cut Off Plate Placa EXIM assunse 224003 015 224003
5. Nota Puede atornillarse una manguera de jard n a la boquilla para drenar el agua de la unidad PREVENCI N DE ACUMULACI N DE XIDO A medida que se evapora el agua los minerales del agua permanecen Con PAQUETE DE PURGA el tiempo esta acumulaci n de minerales puede resultar en xido en los Manguera De filtros y el dep sito Recomendamos la instalaci n de un paquete de purga La Bomba incluido con la unidad o una bomba de purga adquirida por separado para prevenir la acumulaci n de xido y aumentar la vida til de la unidad Una bomba de purga drenar la fuente de forma regular para mantener agua fresca en la unidad Un paquete de purga hace una purga continua de una peque a fracci n de agua mientras la bomba funciona lo que permite que agua fresca reemplace el agua estancada de forma continua Siga las instrucciones a continuaci n para instalar el paquete de purga 1 Corte la manguera de la bomba e inserte los extremos dentados del T de purga en cada punta cortada 2 Inserte un extremo de la l nea de purga a la T de purga y lleve el otro extremo fuera del enfriador a trav s del ca o de desag e Nota Se incluye una pinza de restricci n que puede instalarse en la l nea de purga para restringir la cantidad de agua que se purga La cantidad de agua a purgar depende de la calidad del agua en su zona Comience con 1 2 gal hr y aumente de ser necesario Protector Contra Salpicaduras Panel Del Poste
6. 2 Instale la polea del motor en el eje del motor de manera que est alineada con la polea de transmisi n de la sopladora y ajuste con la llave Allen 3 Desajuste el tornillo del montura del motor 4 Instale la correa en las poleas 10 Tuercas A Cada Lado Que Conectan Quite Dos Tuercas Las Que Unen Los Secciones Paneles Del Fondo Juntas Polea Del A Motor 5 lt otor XS Montura Del Motor Ajustable Horquilla Ajustable ALINEAR LAS POLEAS __ Polea Del Motor Motor Correa __ Polea Del Soplador 110498 2 5 Gire la montura del motor hasta que la correa est ajustada y aplique el tornillo de ajuste para asegurar la correa Verifique la tensi n de la correa seg n las instrucciones de la p gina 13 Nota Puede ser necesario hacer nuevos ajustes a la correa y las poleas luego de finalizada la instalaci n CONEXI N EL CTRICA NADVERTENCIA Las conexiones el ctricas deben ser realizadas por un electricista calificado para garantizar que el cableado cumpla con sus normas locales NADVERTENCIA Tome todas las precauciones de seguridad al trabajar con energ a el ctrica Z ADVERTENCIA Antes de proseguir con la instalaci n aseg rese de que la energ a el ctrica est desconectada hasta que finalice la instalaci n Tornillo Ajustable Nota Se puede controlar esta unidad con un interruptor manual de 6 posiciones que se encuentra en una ferreter a local o con un termostato
7. Del Motor c sssessesssesssesseesseeseeseseseseneeseeess 110393 27 Receptacle Pump Toma De Corriente De La Bomba nirmermnenanennenenena 110361 28 Media Shield Right Protector Para El Medio Evaporativo Derecho 281043 002 29 Media Shield Left Protector Para El Medio Evaporativo Izquierdo 281043 001 30 Water Distributor Housing Caja Del Distribuidor De Agua icocnioninninmmmmmm 281038 001 31 Water Distributor Tube Tubo Del Distribuidor De Agua 3D 23 32 Evaporative Media Set Conjunto De Medio Evaporativo cesses 310117 001 33 Distributor Filter Pad Filtro Del DistribuidOF coonociocionocniononoes 110120 34 Water Reservoir Bandeja Acumuladora De Agua 281041 001 35 Tube Water Delivery Tubo De Agua ai siti 310716 36 Over Flow Assembly Montaje De Desag e pred a 110610 37 Float Valve Flotador scsssssssscssscsesssessesssessssssnsssesssessnsssesensesnssueeensesssseesesesneenesenseaseess FL C 38 Float Shield Salpicadero Del Flotador c cssssssssssesssessessessessssseesssesesesessneeeeeseeees 281006 GOs WPUMO BOM a o alal lacas es 110429 41 Pump Mount Montura De La Bomb a cccccccececsesessessessesseeseseseeseeseseseeeseseeseentees 218002 012 42 Pump Retainer Sujetador De La Bomba s ssscssecsesssesssecseessessnsesnesseeese
8. Recept culos del Motor y Bomba 120 VOLTIOS Azul Negro BOMBA Blanco Marron Naranja Verde L A Negro Interruptor Rojo Blanco Naranja Verde NOTA De utilizar un motor de velocidad nica no utilice los cables el ctricos ROJOS del motor o recept culo Cubra con cinta ambas terminales ROJAS Empalme De Pl stico Motor Del Ventilador Z PRECAUCION Los receptaculos de la caja de conexiones son Unicamente para el motor y la bomba No conecte nada mas al receptaculo Azul Negro Blanco e Marr n BOMBA Naranja Verde A Negro ALTO Interruptor Rojo BAJO Blanco e A Naranja COMUN Verde TIERRA NADVERTENCIA Aseg rese de gue el gabinete del enfriador tenga una conexi n adecuada a tierra para una mayor seguridad y e Empalme De Pl stico a i protecci n del eguipo Motor Del Ventilador 110498 2 11 CONEXI N DE AGUA Nota No conecte la alimentaci n de agua a equipos de agua blanda Grifo V lvula De A A Apagado INSTALACION DE VALVULA DE AGUA ACOPLADA Ai Se reguiere un suministro de agua constante para el funcionamiento del enfriador Sila fuente de agua viene de un grifo externo se deber comprar F rula Tuerca Tubo de e instalar una llave y una v lvula de paso Pl stico o 1 Instale la llave de paso y la v lvula de agua en el grifo Cobre 2 Conecte la unidad al grifo con tubos de pl stico o cobre de 14 de Sa
9. Rueda sssi os a 16BW 16BW 20BW 20BW 23 Pulley Blower Wheel Polea De La Rueda pi aa 110275 110275 110276 110276 24 Drive Belt Correa sessssssessssesssssessssesssssesssrecssssecssseeasssnesssereses as tae X 25 Bearings Blower Wheel Shaft Cojinetes Del Eje De La Rueda 110351 110351 110351 110351 26 Receptacle Motor Toma De Corriente Del Motor scesssecseessessessessseeseeseseseseneeseeees 110393 110393 110393 110393 27 Receptacle Pump Toma De Corriente De La BOMba oocnionicniionncinmmnss 110361 110361 110361 110361 28 Media Shield Right Protector Para El Medio Evaporativo Direcho 281043 002 281045 002 281044 002 281046 002 29 Media Shield Left Protector Para El Medio Evaporativo Izquierdo 281043 001 281045 001 281044 001 281046 001 30 Water Distributor Housing Caja Del Distribuidor De Agua uu 281038 001 281033 001 281038 001 281033 001 31 Water Distributor Tube Tubo Del Distribuidor De Agua 3D 23 3D 23 3D 23 3D 23 32 Evaporative Media Set Conjunto De Medio Evaporativo essences 310117 001 310118 001 310117 002 310118 002 33 Distributor Filter Pad Filtro Del Distribuidor a w 110120 110120 110120 110120 34 Water Reservoir Bandeja Acumuladora De Agua 281041 001 281042 001 281041 001 281042 001 35 Tube Water Delivery Tubo De Agua
10. Trasero Ca o De Desag e T De Purga i P L nea De Purga e a De Restricci n Ca o De Desag e AMPERIO Y TENSI N DE LA CORREA Z PRECAUCION No intente instalar la unidad por completo sin la ayuda de un electricista o alguien familiarizado con las pruebas de consumo de corriente El incumplimiento de las presentes instrucciones puede anular su garant a Esta unidad est equipada con una polea ajustable de transmisi n del motor para ajustar la velocidad de la rueda de la sopladora seg n la carga requerida para los distintos sistemas de conductos Es importante que la polea de transmisi n del motor sea ajustada al tama o correcto para asegurar un m ximo suministro de aire sin da ar el motor Aseg rese de seguir estas instrucciones 12 110498 2 1 Aseg rese de que la conexi n el ctrica de la unidad est completa y de conformidad con las normas de seguridad y los requisitos locales Polea Del 2 Instale nuevamente los paneles de inspecci n Active la energ a encienda ff Motor el agua y la bomba y permita que el enfriador funcione unos minutos para Motor humedecer los filtros l Disminuir 3 Verifique el amperio y confirme que est de acuerdo con el amperio Corea Amperio detallado en la etiqueta de especificaciones del motor A Poja Polea Del e Si el consumo de corriente es menor que el indicado por el motor corte Soplador la corriente el ctrica y quite los paneles de inspecci n Desenchufe
11. costs incurred Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you How to obtain service under this warranty Within the limitations of this warranty purchaser with inoperative units should contact the dealer where you purchased the cooler If for any reason you are not satisfied with the response from the dealer contact Customer Service at 800 643 8341 for instructions on how to obtain service within warranty as listed above This warranty gives the customer specific legal rights and you may also have other rights which vary from province to province or state to state Register your product at www championcooler com 8 110498 2 Csr MANUAL DE INSTALACION Y OPERACION ENFRIADOR EVAPORATIVO DE ADMISSION SIMPLE Encierrre con un circulo el modelo de su enfriador ADA51 ADA5112 ADA71 ADA7112 y escribe el n mero de s rie abajo ASA51 ASA5112 ASA71 ASA7112 AUA51 AUA5112 AUA71 AUA7112 Fecha de Compra N mero De S rie LEA CON CUIDADO TODO ESTE MANUAL ANTES DE INSTALAR LA UNIDAD TABLA DE CONTENIDO LEA Y CONSERVE ESTAS INSTRUCCIONES Reglas De Seguridad ocococonononococnnnnnonenenncnrnonennnnraranos 9 NORMAS DE SEGURIDAD C mo Funciona Los Enfriadores Evaporativos 9 1 Lea todas las instrucciones con detenimiento Instalaci n coastal isepid dci 10 2 Las conexi
12. dE ol ola agua se evapora y se absorbe el calor Al salir de una piscina temperatura de toda la Casa mientras sopla el viento el enfriamiento por evaporaci n hace que se sienta fresco a n cuando el aire sea c lido Los ventiladores llevan el aire por Esta unidad funciona con el mismo principio Se hace circular los conductos y aire a trav s de almohadillas filtrantes h medas donde el se dirige hacia aire se enfr a por evaporaci n y luego se propaga por todo el abajo enfriando edificio Es la combinaci n de aire enfriado y movimiento de el interior i i La entrada aire sobre su piel lo gue le hace sentir fresco y salida A diferencia de otros sistemas de enfriamiento gue de Ale redistribuyen el aire el enfriador por evaporaci n ingresa aire mantiene el fresco de forma continua mientras expulsa el aire viciado ar fresco en circulaci n Usted renueva el aire por completo cada 2 a 4 minutos al abrir ventanas o puertas al utilizar la ventilaci n de techo Up Dux o una combinaci n de ambas El aire siempre est fresco no rancio cargado de humo y olores como suele ocurrir con el aire acondicionado por refrigeraci n A medida que el aire se clienta sube y sale por las ventanas abiertas y o las rejillas del techo 110498 2 9 INSTALACI N NPRECAUCIONES Tome las siguientes precauciones antes de instalar su enfriador e Antes de la instalaci n aseg rese de que su sistema el ctrico est preparado para el con
13. de enfriamiento Recomendamos el uso de equipo original las almohadillas de repuesto de medio de filtrado MasterCool para una mayor capacidad de enfriamiento NOTA De instalar almohadillas de la competencia con ngulos iguales desestime la colocaci n indicada del medio de filtrado Puerto de Aceite ACEITADO DE COJINETES 1 Los cojinetes de la sopladora deben aceitarse cada a o con aceite no detergente de grado 20 30 2 Ubique y abra el puerto de aceite en cada uno de los cojinetes de la sopladora y agregue unas gotas de aceite 3 A ada aceite a los cojinetes del motor si el motor tiene entradas de aceite Nota Muchos motores est n sellados y no requieren la adici n de aceite Z PRECAUCION No coloque aceite de mas en el motor ya que puede ocasionar que el motor se funda por exceso de aceite en los engranajes LIMPIEZA DE BOMBA 1 Se debe limpiar la bomba al menos una vez al a o o m s en caso de acumulaci n de residuos 2 Desenchufe el motor y la bomba de la caja de conexiones y desconecte el tubo de agua si a n permanece conectado 3 Con un destornillador abra las abrazaderas pl sticas de retenci n hacia arriba fuera de los encajes de la montura de la bomba Deslice la bomba hacia afuera de la montura Quite la bomba de la red o canasta de filtro y quite la base de la bomba Limpie la bomba gire el rotor para asegurar que tenga movimiento libre Quite el pico de la bomba y verifique
14. el motor dentro del enfriador eso lo proteger si alguien enciende la unidad mientras usted trabaja dentro de la misma Esto debe realizarse por su propia seguridad Ajuste la polea a un TENSION DE LA diametro mayor y reajuste la tensi n de la correa Enchufe CORREA el motor instale los paneles de inspecci n y pruebe el 3 Libras consumo de corriente nuevamente Repita el proceso 3 4 Pulgadas hasta lograr el consumo correcto de corriente Nota El incremento del di metro de la polea del motor aumenta el consumo de corriente La reducci n del di metro de la polea del motor disminuye el consumo de corriente Z PRECAUCION NO opere el enfriador con un amperio superior al indicado en la placa del motor Esto da ar el Tornillo Ajustable motor 4 Verifique la tensi n de la correa luego de ajustar la polea Una fuerza de 3 libras deber a desviar la correa unas 3 4 pulgadas Reajuste la correa de ser necesario aflojando el tornillo de ajuste gire el motor hasta que tenga la tensi n correcta de la correa y vuelva a apretar el tornillo OPERACI N NOTAS Estos enfriadores pueden utilizarse sin agua a los fines de ventilaci n Cuando el aire exterior est fresco por ejemplo por la noche o cuando la humedad es alta puede apagarse la bomba de agua Para detener el suministro de aire caliente al prender el enfriador encienda solo la bomba durante los primeros minutos luego encienda el motor de la sopladora Para que el enfriador
15. every effort to keep the media intact a 4 The original media has a standard life of 5 years but in areas with very high mineral content the media may have to be replaced sooner 5 When reinstalling existing or installing new replacement pads ensure pads are installed in the correct configuration Place the media into the unit with the steeper flute angle sloping down towards the air inlet side This provides the most effective water flow to the pads allowing higher cooling efficiencies We recommend using original equipment MasterCool media replacement pads for highest cooling capabilites NOTE If competitor pads with equal angles are installed disregard directional placement of media Blower Bearing OIL BEARINGS Oil Cup 1 The blower bearings should be oiled each year with non detergent 20 30 weight oil A 2 Locate and open the oil cup on each of the blower bearings and add a few drops of oil 3 Add oil to motor bearings if motor has oil lines Note Many motors are sealed and do not require addition of oil CAUTION Do not over oil the motor as this can cause the motor to burn out due to excessive oil on windings CLEAN PUMP Pump should be cleaned at least once a year or more often if debris accumulates Unplug motor and pump from junction box and disconnect water tube if not already accomplished Using a screw driver pry plastic retaining fastners straight up out of the pump mounting bracket Slide the pump of
16. fabricante El cliente ser responsable por todos los costos de mano de obra incurridos Algunos estados no permiten la exclusi n o la limitaci n de da os incidentales o resultantes por lo tanto es posible que las limitaciones o exclusiones detalladas anteriormente no se apliquen a usted C mo Obtener Servicio Bajo Esta Garant a Dentro de las limitaciones de la presente garant a el comprador que tanga unidades fuera de funcionamiento debe comunicarse con el concesionario donde compr el enfriador Si por alguna raz n no queda satisfecho con la respuesta por parte del concesionario debe comunicarse con el servicio de atenci n al cliente al 800 643 8341 para obtener instrucciones sobre c mo obtener servicio dentro de la garant a como se indica anteriormente Esta garant a le confiere al cliente derechos espec ficos Adem s el cliente puede gozar de otros derechos que var an seg n la provincia o el estado Registre su producto en www championcooler com Champion Cooler Most 5800 Murray St Little Rock AR 72209 www championcooler com o 24 110498 2
17. tal como el Termostato de Pared de Champion Masterstat modelo n 110423 2 Para la instalaci n del termostato consulte el manual operativo del mismo Siga los pasos a continuaci n para la instalaci n del interruptor manual 1 Determine la ubicaci n para el interruptor de 6 posiciones en la pared interna 2 Alimente el interruptor con energ a de 120V o 240V seg n los voltajes del motor y la bomba 3 Quite los tornillos que fijan la caja de conexiones a la cabina de enfriamiento 4 Traiga cuatro conductores m s una toma de tierra desde el interruptor Quite los Tornillos Para hasta la caja de conexiones del enfriador similar al cable Romex de dos Acceder a las Conexiones alambres de Cableado NPRECAUCI N Aseg rese de utilizar cables de tama o adecuado y Caja de Conexiones respete las normas locales de electricidad 5 Conecte los cuatro cables conductores con las terminales del motor y los recept culos de la bomba ubicados en la caja de conexiones Siga los diagramas de conexi n a continuaci n para las instalaciones de 120V y 240V 6 Instale nuevamente la caja de conexiones en la cabina de enfriamiento 7 Conecte el motor y los enchufes de la bomba en los recept culos 8 Siga las instrucciones del interruptor el ctrico para conectar los cuatro conductores y el cable de energ a al interruptor Advertencia El cable de la bomba debe estar sujeto con la horquilla de retenci n para evitar contacto con el agua
18. the windows one inch and try step 4 again IF It stays on the screen lightly THEN PERFECT You are done Enjoy your cooler Notes When switching to low cool you must re balance your home Repeat step 4 Once you balance your home you can cool some areas more than others by opening those windows more and closing the others by the same amount Repeat step 4 to make sure your home is still air balanced 110498 2 5 MAINTENANCE Regular maintenance on your cooler will increase performance and extend the life of your cooler NWARNING Before accomplishing any maintenance ensure power is turned off and the motor and pump are unplugged START OF SEASON MAINTENANCE Accomplish these basic steps before the temperatures reguire cooling in case you have to acguire replacement parts CLEAN MEDIA 1 With power OFF remove inspection panels top panels and inlet grille to access ESSSSS interior of unit Place panels in a flat secure place to protect them from being bent or damaged 2 Disconnect water tube and lift off water distribution tray accessing the media Ng NON OO Air Enters Remove filter pad on top A Air Exits 3 Remove and inspect media pads Using a garden hose sprayer wash the media W y gt pad ensuring openings are clear of obstruction and dirt Some light scrubbing Y may be required to remove mineral deposits Do not use harsh detergents or 15 pressure washers in cleaning Make
19. this unit before beginning the installation and DO NOT reconnect until installation is complete PARTS AND TOOLS NEEDED e Motor with Motor Pulley purchased separately e 5 32 Allen Wrench for pulley installation e 7 16 Wrench or Crescent Wrench e Phillips Screwdriver e Sill cock or water valve and tubing e Multimeter for amp reading SEPARATING SECTIONS Follow the steps below to separate the sections of the unit if desired for ease of installation 1 Remove four bolts two on each side from the inside center post of the unit connecting the wet section to the blower section 2 On a few models two bolts on the interior of the unit attaching the bottom pans of the two sections will need to be removed as well MOTOR INSTALLATION Note Motor must be purchased separately See Motor Specification Table for motors that can be used 1 For typical 120V installation install motor cord provided to motor purchased separately Follow motor electrical diagram using the following color code BLACK HIGH RED LOW WHITE COMMON GREEN GROUND 2 When installing a 1 hp motor reverse the adjustable yolk to accommodate the larger motor Adjust the cradle spacing as needed for size of motor Mount the blower motor onto the yokes of the motor mount Fasten with provided motor clips 3 Leave motor cord unplugged until electrical portion of installation is complete PULLEY INSTALLATION 1 Open adjustable pulley abou
20. 015 224004 003 224004 003 218001 035 218001 035 218001 038 218001 038 E Blower Housing Support Right Soporte Para La Caja De La Rueda Derecho do doo lo el il ee Se ER WD I b Blower Housing Support Left Soporte Para La Caja De La Rueda Izquierdo 218001 036 218001 036 218001 038 218001 038 Gil PARMA cases ci tia aaasta 222130 078 222130 078 222140 057 222140 057 Electrical Junction Box Caja De Empalme eseesesssesecseessessneesnessneesnessneesnenses 322009 001 322009 001 322009 001 322009 001 Motor Mount Montura Del Motor cscssescsssessssesecsssesseeessnesessseesntsessnstessetesenteesnaess 314003 011 314003 011 314003 012 314003 012 Motor Mount Clip Set Conjunto De Seguros Para Montar Motor 314005 001 314005 001 314005 001 314005 001 Motor MOLOTES 24125443 1 0880 teata Tanana emana ap Memm aaa e E i Pulley Motor Polea Del MOtor ccsssessesssessecseessessessesssessusssssssesnsssssseesnsesteeneseneeeseees 7 20 Electrical Cord Motor 115V Cable El ctrico Del Motor 115V rmusi 110372 110372 110372 110372 20 Electrical Cord Motor 230V Cable El ctrico Del Motor 230V 8110372 2 110372 2 110372 2 110372 2 21 Shaft Blower Wheel Eje De La Rueda mmiiiemmnennmanennnaeenenaeaneaneannanenene 110183 110183 110183 110183 22 Blower Wheel
21. 2 17 PARTS LIST DOWN DISCHARGE CONFIGURATION LISTA DE PIEZAS CONFIGURACION DE DESCARGA DESCENDENTE No N Description Descripci n ADA51 ADA5112 ADA71 ADA7112 1 Top Cabinet Tapa De La Cala ira pad 222130 070 222130 070 222140 053 222140 053 2 TopAccess Panel Panel Superior De ACCESO mmrenmsnnnasennannmananeaanmananeai 222130 074 222130 075 222130 074 222130 075 3 Bottom Blower Section Base De La Secci n De La Rueda 322130 068 322130 068 322140 051 322140 051 4 Bottom Wet Module Base De La Secci n De Agua mnimnernnernennsenenane 222130 072 222130 073 222130 072 222130 073 B gt Front Panel Panel Del Frente ion soda 222130 076 222130 076 222140 055 222140 055 6 Inspection Panel 2 reg Panel De Inspecci n 2 req coccion 224130 002 224130 002 224140 002 224140 002 7 Center Post Right Poste Central Derecho ou essessssessseeestesseseneeseesseesseesnensneesnees 222130 062 222130 062 222140 045 222140 045 8 Center Post Left Poste Central Izquierdo 222130 063 222130 063 222140 046 222140 046 9 Back Post Right Poste Trasero Derecho sssssisrrsrsriinsssssssssssssrnsunnunrnnrenrnneeneseeesans 222130 064 222130 066 222140 047 222140 049 10 Back Post Left Poste Trasero Izquierdo cas a 222130 065 222130 067 222140 048 222140 050 11 Blower Housing Caja De La R edaa is
22. 22130 064 10 Back Post Left Poste Trasero IZQUIe rdO c ssesssessesessesesessnessessessuesstssseeseeseeeneeeees 222130 065 11 Blower Housing Caja De La Rueda sa si 824130 204 12 Cut Off Plate Placa Externa sccsccssesssessssessscseesnessessssssnsesnssseesnsesnseseesneess 224003 015 13 Blower Support Bracket 2 req Soporte Para La Caja De La Rueda 2 req 218123 001 14 GIL Parla oi ida 222130 078 15 Electrical Junction Box Caja De Empalme aa TA 322009 001 16 Motor Mount Montura Del Motor 0 0 csscescescessesessecsesseeeessesenseesensesssseesesseeeeeeeeeneens 314003 011 17 Motor Mount Clip Set Conjunto De Seguros Para Montar Motor 314005 001 18 Motor Mo a e en Lo k 19 Pulley Motor Polea Del Motor mmseasnaanennaaveanaavaanaanaanaanaanaanaanaanaanaa 20 Electrical Cord Motor 115V Cable El ctrico Del Motor 115V ou eee 110372 20 Electrical Cord Motor 230V Cable El ctrico Del Motor 230V ou 110372 2 21 Shaft Blower Wheel Eje De La Rueda eesseesseessecsesssessnecsncsseseneseresseesssesnseneceneesneess 110183 22 Blower Wheel y RUCKA cuasi tiara 16BW 23 Pulley Blower Wheel Polea De La Rueda TA 110275 24 Drive Belt Coleco ave RU ekat neid 25 Bearings Blower Wheel Shaft Cojinetes Del Eje De La Rueda t 110351 26 Receptacle Motor Toma De Corriente
23. 81038 001 3D 23 310117 002 110120 281041 001 310716 110610 FL C 281006 110429 218002 012 110714 110847 310586 AUA7112 322140 054 222130 075 322140 052 222130 073 222140 058 224140 002 222140 045 222140 046 222140 049 222140 050 324140 204 224004 003 218001 038 222140 057 322009 001 314003 012 314005 001 110372 1 110372 2 110183 20BW 110276 110351 110393 110361 281046 002 281046 001 281033 001 3D 23 310118 002 110120 281042 001 310716 110610 FL C 281006 110429 218002 012 110714 110847 310586 110498 2 EXPLODED ILLUSTRATION UP DISCHARGE CONFIGURATION ILUSTRACI N DE PIEZAS CONFIGURACI N DE DESCARGA SUPERIOR 110498 2 POLITICA DE GARANTIA LIMITADA PARA CUALGUIER RECLAMO RELACIONADO CON LA GARANTIA ES NECESARIO PRESENTAR EL RECIBO COMO PRUEBA DE COMPRA Esta garant a se extiende solo al comprador original de este enfriador evaporativo siempre y cuando la unidad sea instalada y utilizada en condiciones normales contra defectos de fabricaci n y materiales como se detalla a continuaci n Un 1 a o a partir de la fecha de la venta de los componentes del gabinete Cinco 5 a os para el medio evaporativo que se considera componente desechable y debe reemplazarse peri dicamente Dos 2 a os para el motor original si es proporcionado por Champion Cooler El fabrican
24. G Ensure Orange Sis cooler cabinet is proper Green ly grounded to a suitable Orange Green TO SWITCH ground connection for GROUND e WIRE NUT maximum safety and BLOWER MOTOR protection of equipment COMMON 110498 2 3 WATER CONNECTION Note Do not connect the water supply to any soft water applications SILLCOCK INSTALLATION A steady water supply is required for the operation of this cooler If water source comes from an external water faucet a sillcock and shutoff valve will need to be purchased and installed Faucet Water Shut N Off Valve Nut Copper Or Plastic Line To Cooler 1 Install sillcock and water valve on faucet 2 Run Y plastic or copper tubing from the faucet to the unit Sillcock With std 3 Install one end of tubing to water valve by placing nut and ferrule on Hose Connection tubing and tightening the nut until water tight FLOAT VALVE INSTALLATION Refer to illustration 1 Remove items 1 2 3 and 4 from float 2 Insert float body through hole in media shield and back post panel as shown 3 Install washer 1 and nut 2 Tighten to keep float from turning Place nut 4 and ferrule 3 on water supply line Connect to float fitting and tighten until water tight 4 Slide float shield over float body until it snaps into place Note After installation is complete and water is turned on the float level will need to be adjusted 5 Bend rod to adjust float Water leve
25. HURA PROFUNDIDAD ANCHURA ALTURA 177 272 28 42 45 17 3 4 17 3 4 5112 Serie 71 Serie 7112 Serie Incluye el peso del motor ESPECIFICACIONES DEL MOTOR PESO POLEA DEL O O MODELOS MOTOR N VELOCIDAD VOLTIOS AMPERAJE i MOTOR NO MODELO CORREA N 110445 110279 002 ADA51 8 110208 4L 520 110447 7 110279 004 ADA5112 110229 4L 536 e C V 110475 y 110279 004 ASA51 8 110449 i 110279 004 ASA5112 AUA51 amp 110480 3 110279 004 AUA5112 110222 4L 510 110447 i 110279 002 ADA71 8 110475 A 110279 002 ADA7112 ART 110449 110279 004 ASA71 8 Serie 110480 110279 004 ASA7112 110471 110279 003 AUA71 8 110458 110279 003 AUA7112 Amperaje listado es del c digo el ctrico nacional para la velocidad alta 51 amp 5112 Serie 110212 4L 570 110230 4L 640 110213 4L 670 110213 4L 670 110498 2 15 No arranca o no sale aire Sale poco aire cuando la unidad est funcionando Agua est drenando en el tejado Olor a encerrado olor desagradable LA LOCALIZACION DE AVERIAS 1 No llega corriente 1 Revise la corriente Fusible fundido o Cortacircuito desactivado Cable el ctrico da ado Cambie el fusible o restablecer el cortacircuito Reemplace el cable 2 Correa muy floja o apretada 2 Ajuste la tensi n de la correa 3 Motor recalentado Correa muy apretada Cojinetes de la rueda est n secos Di metro de la
26. Llave de paso o v lvula de agua y tubos e Mult metro para lectura de amperios SEPARACI N DE SECCIONES Siga los pasos a continuaci n para separar las secciones de la unidad si lo prefiere para facilitar la instalaci n 1 Quite las cuatro tuercas dos a cada lado del poste central interno de la unidad conectando la secci n h meda con la secci n de la sopladora 2 En algunos modelos tambi n ser necesario guitar dos tuercas del interior de la unidad que unen los paneles del fondo de ambas secciones INSTALACI N DEL MOTOR Nota El motor se adquiere por separado Vea la Tabla de Especificaciones de Motor para conocer los motores que pueden utilizarse 1 Para una instalaci n t pica de 120V conecte el cable del motor incluido al motor adquirido por separado Siga el diagrama el ctrico del motor utilizando el siguiente c digo de colores NEGRO ALTO ROJO BAJO BLANCO COM N VERDE TIERRA 2 Para instalar un motor de 1 CV mueva la horquilla ajustable para hacer lugar al motor m s grande Ajuste el tama o del soporte seg n sea necesario para el tama o del motor Monte el motor de la sopladora a las horquillas de la montura del motor Asegure el mismo con los seguros incluidos para el motor 3 Deje el enchufe del motor desconectado hasta que la parte el ctrica de la instalaci n est completa INSTALACI N DE POLEA 1 Abra la polea ajustable unas cinco vueltas completas hasta su di metro menor
27. ad 20 110498 2 N EXPLODED ILLUSTRATION SIDE DISCHARGE CONFIGURATION ILUSTRACION DE PIEZAS CONFIGURACION DE DESCARGA LATERAL 32 110498 2 PARTS LIST UP DISCHARGE CONFIGURATION LISTA DE PIEZAS CONFIGURACION DE DESCARGA SUPERIOR No N Description Descripci n AUA51 1 Top Cabinet Tapa De La Caja si A 322130 071 2 TopAccess Panel Panel Superior De Acceso we 222130 074 3 Bottom Blower Section Base De La Secci n De La Rueda 322130 069 4 Bottom Wet Module Base De La Secci n De Agua mnmnsemanenesnns 222130 072 5 Front Panel Panel Del Frente ansins ala 222130 079 6 Inspection Panel 2 reg Panel De Inspecci n 2 reg sssssescseessecsessessseestesseesseesees 224130 002 7 Center Post Right Poste Central Derecho sssessssssssseessessessesseesnsssnssseeseestseneeeess 222130 062 8 Center Post Left Poste Central IZQUi rdO cesssessesssesseessesssessessessnessessessetestseneeeees 222130 063 9 Back Post Right Poste Trasero DereCho c sceccessesseesessessesstestesteenesseseeseeeesteaeeess 2
28. de reducing temperature ofwhole house Fan forced air travels V through ducts M and falls as it A settles cooling the interior M P As air warms it rises and exits through open windows and or ceiling vents Intake and exhaust air Keeps the cooled air circulating INSTALLATION ACAUTIONS Before installing the cooler note the following items e Before installation ensure your existing electrical system is rated for the additional amperage draw from unit e Installation inside attic areas is NOT recommended e If installing unit on ground ensure surface area is level well packed and will not erode or become unstable with water erosion e If installing on brace or existing construction ensure structure will hold the operating weight of the cooler See specification table for operating weight e Ensure entire unit is sufficiently supported If supporting the unit with legs at each corner the middle of the unit where the two sections join must be supported as well We strongly recommend consulting a professional contractor if installation will require cutting through existing structure such as walls or roof Do not screw or drill within 5 inches of the bottom of the wet section as you could puncture the reservoir e Ensure all electrical work is accomplished to local standards An electrician may be needed for correct and safe wiring NWARNING Disconnect all electrical service that will be used for
29. el enfriamiento por si necesita adquirir piezas de repuesto LIMPIEZA DE MEDIO DE FILTRADO 1 Con la energ a CORTADA quite los paneles de inspecci n los paneles superiores y la parrilla de entrada para tener acceso al interior de la unidad Coloque los paneles sobre una superficie plana y segura para protegerlos contra da o o dobleces 2 Desconecte el tubo de agua y levante la fuente de distribuci n de agua para acceder al medio de filtrado Quite la almohadilla filtrante superior 3 Quite e inspeccione las almohadillas del medio de filtrado Con un pulverizador de jard n limpie la almohadilla del medio de filtrado asegur ndose de que las aperturas est n libres de obstrucciones y suciedad Puede ser necesario frotar ligeramente para quitar los dep sitos minerales No utilice detergentes fuertes o limpiadores a presi n para limpiar Intente que el medio de filtrado quede intacto 4 El medio de filtrado original tiene una vida est ndar de 5 a os pero en reas de contenido mineral muy elevado puede ser necesario cambiar el medio de filtrado con anterioridad 5 Al reinstalar almohadillas existentes o al instalar almohadillas de repuesto nuevos aseg rese de instalar las mismos de la manera correcta e Coloque el medio de filtrado en la unidad con el ngulo de onda m s escarpado inclin ndose al lado de la entrada de aire Esto facilita un flujo m s efectivo de agua hacia las almohadillas lo que permite mayor eficiencia
30. es 213 263 42 48 19 3 8 19 3 4 7112 Series 233 300 42 52 19 3 4 19 3 4 Includes motor weight MOTOR SPECIFICATIONS MODELS H P MOTOR PN VOLTS AMPS WEIGHT LBS MOTOR PULLEY P N 110445 110279 002 ADA51 8 110208 4L 520 110447 i 110279 004 ADA5112 110229 4L 530 3 4 HP 51 amp 5112 110475 j 110279 004 ASA51 amp 110449 110279 004 ASA5112 AUAS1 8 110480 110279 004 AUA5112 110222 4L 510 110447 y 110279 002 ADA71 8 110475 l 110279 002 AARDE 7187112 110449 110279 004 ASA71 8 Series 110480 110279 004 ASA7112 110471 110279 003 AUA71 8 110458 110279 003 AUA7112 Amperage shown is from National Electrical Code for high speed TROUBLESHOOTING GUIDE 1 No electrical power to unit 1 Check Power Blown Fuse or Tripped Circuit Breaker e Replace fuse or reset breaker e Electrical cord damage e Replace Cord 2 Belt too loose or too tight 2 Adjust belt tension Failure to start or no air delivery 3 Motor overheated 3 Determine cause of overheating Belttootight e Adjust pulley tension Blower bearings dry e Oil blower bearings e Motor pulley diameter too large e Adjust pulley to correct diameter 4 Motor locked 4 Replace motor 1 Insufficient air exhaust 1 Open doors or widows to increase air flow 110212 4L 570 Series 110230 4L 640 110213 4L 670 110213 4L 670 ETI A 2 Belt too loose 2 Adjus
31. evaporativo sea efectivo debe haber una ventilaci n adecuada Si no hay un escape la presi n y humedad se acumular n dentro del edificio Usted facilita el escape al abrir puertas o ventanas para permitir que el aire viciado del edificio salga al exterior Puede instalar tambi n rejillas regulables de ventilaci n en el tico para descargar el aire en el tico La combinaci n de rejillas regulables de ventilaci n en el tico y un termostato puede brindarle una operaci n completamente autom tica Un concepto frecuentemente errado sobre el enfriamiento por evaporaci n es la cantidad de aire que debe liberarse Cu nto debe abrir sus ventanas Los dos m todos siguientes le ayudar n a determinar cu nto debe abrir sus ventanas M TODO DE CFM SUPERFICIE DE VENTANAS Para un flujo adecuado de aire se necesita una abertura de al menos dos pies cuadrados 288 pulgadas cuadradas por cada 1000 CFM de su unidad Ejemplo Con 3320 CFM el modelo ADA 51 1 2 CV requiere 6 6 pies cuadrados 950 pulgadas cuadradas de abertura 3320 1000 2 6 6 Multiplique el n mero de ventanas por el ancho de las ventanas en pulgadas y divida ese n mero por el n mero de pulgadas cuadradas necesarias seg n la unidad de tama o Esto le indicar a qu altura debe levantar las ventanas En este ejemplo cuatro ventanas de 36 pulgadas de ancho deber an levantarse 6 6 pulgadas cada una M TODO DE SUCCI N DE PA UELO DE PAPEL 1 Tome un trozo de pa
32. f the mounting bracket Extract pump from straining basket or netting and remove base of pump Clean pump turn impeller to ensure free movement Remove pump spout and check for blockage Reinstall pump base and verify it is secure Before reinstalling pump check water hose bleeder line and water distributor tube to ensure there is no blockage in any lines Reinstall the pump by sliding pump onto mounting bracket and reinserting the plastic i retainers to ensure pump stays in upright postion WO 09 51 0 ON 8 9 Ni o 11 Reinstall water tube to the pump outlet spout CHECK BELT 1 Before unit is turned on check that belt condition is good If belt must be replaced install same sized belt 2 Verify belt tension is correct 3 4 deflection with 3 lbs of force END OF SEASON SHUTDOWN The cooler should be prepared before any extended period of non use and especially before winter shutdown 1 Drain all water from unit supply line and pump to ensure no damage occurs from freezing Keep water line disconnected from both unit and supply line 2 Unplug motor and pump from junction box 3 Clean unit 4 Cover unit to protect finish for long periods of non use 6 110498 2 GENERAL SPECIFICATIONS MODELS WEIGHT lbs CABINET DIMENSIONS in DUCT OPENING in DRY OPERATING HEIGHT WEIGHT DEPTH WIDTH HEIGHT 227 28 42 45 17 3 4 17 3 4 51 Series 177 5112 Series 190 257 28 42 49 17 3 4 17 3 4 71 Seri
33. ficiente abertura para que salga aire 3 Apri telas 1 Abra m s las ventanas o puertas 2 El medio evaporativo no est mojado Filtros obstruidos Agujeros del tubo obstruidos Bomba no funciona 1 Insuficiente salida de aire 1 Abra puertas o ventanas 16 2 Revise la distribuci n de agua Limpie los filtros L mpielos C mbiela o l mpiela Desconecte la unidad 110498 2 ILLUSTRATED PARTS REPLACEMENT LIST LISTA ILLUSTRADA DE PIEZAS DE REPUESTO SINGLE INLET EVAPORATIVE COOLER ENFRIADOR DE ENTRADA SIMPLE Type Models Modelos Pages Paginas Down Discharge Descarga Descendente ADA51 ADA5112 ADA71 ADA7 112 ooococccnnccccccnconananccnnnnnno 18 19 Side Discharge Descarga Lateral ASA51 ASA5112 ASA71 ASA7112 doococccccnocccnonancnonnnnnnnnno 20 21 Up Discharge Descarga Superior AUA51 AUA5112 AUA71 AUA7112 000 eects 22 23 When ordering parts please be sure to furnish the following information on all orders Failure to do so may delay your order Al pedir piezas incluya toda la informaci n siguiente con su pedido El no proporcionar toda esta informaci n resultar en una demora Cooler model number El modelo de su enfriador Cooler serial number N mero de serie de la unidad Motor HP C V del motor Description and part number Descripci n y n mero de pieza Date of purchase Fecha de compra 110498
34. iissiisirsisiiisiiiinniisioisianiianas 324130 202 324130 202 324140 202 324140 202 12 Cut Off Plate Placa ExtOIMA coccion 224003 015 224003 015 224004 003 224004 003 13 Blower Housing Supports 2 reg Soporte Para La Caja De La Rueda 2 req 218001 034 218001 034 218001 037 218001 037 14 GM A 222130 078 222130 078 222140 057 222140 057 15 Electrical Junction Box Caja De Empalme ccoo 322009 001 322009 001 322009 001 322009 001 16 Motor Mount Montura Del Motor sceseesesseesseeesecsnessueessessueesnessneesnersneeeneeesnseey 314003 011 314003 011 314003 012 314003 012 17 Motor Mount Clip Set Conjunto De Seguros Para Montar Motor 314005 001 314005 001 314005 001 314005 001 gs mms 0 0 avd 0 0 cere opera erence revere kaan aia E i j i 19 Pulley Motor Pol a DelMotoF c woo arar tana s E 20 Electrical Cord Motor 115V Cable El ctrico Del Motor 115V ou eee 110372 110372 110372 110372 20 Electrical Cord Motor 230V Cable El ctrico Del Motor 230V we 110372 2 110372 2 110372 2 110372 2 21 Shaft Blower Wheel Eje De La Rueda gn 110183 110183 110183 110183 22 Blower Wheel Rueda ocicccioniinnciininnsess ee sist 16BW 16BW 20BW 20BW 23 Pulley Blower Wheel Polea De La Rueda 110275 110275 110276 110276 24 Drive Belt loa ajana jaaa i 3 j 25 Bearings Blower Wheel Shaft Cojinetes Del Eje De La Rueda
35. l should be about 1 inch below the top opening of the overflow pipe OVERFLOW INSTALLATION 1 Remove nut and place nipple through the hole in the pan with the rubber washer between the pan and the head of the drain nipple 2 Screw nut onto nipple and draw up tight against bottom pan 3 Screw overflow pipe into nipple This overflow pipe may be removed to drain pan when necessary Note A garden hose may be screwed onto the drain nipple to drain water away from the unit SCALE BUILDUP PREVENTION As water evaporates minerals that were in the water will remain Over time this accumulation of minerals will cause scaling on the pads and in the reservoir We recommend the installation of either a bleed off kit included in unit or a purge pump purchased separately to help prevent scale build up and increase the life of the unit A purge pump will drain the pan every few hours of pump operation to keep fresh water in the unit A bleed off kit will continually bleed off a small portion of water while the pump is running allowing fresh water to continually replace the old stagnate water Follow the instructions below for installing the bleed off kit 1 Cut the pump hose and insert the barbed ends of the bleeder tee into each cut end 2 Insert one end of the bleeder tubing onto the bleeder tee and run the other end out of the cooler through the overflow pipe Note A restrictor clamp is provided which if desired may be installed
36. mnnmananeanmananeaa 281006 281006 281006 281006 39 PUMP BOM a AE EE 110429 110429 110429 110429 41 Pump Mount Montura De La Bomba scesseesecsesesteeseeesessneeenessneesnieeseesnersneeenees 218002 012 218002 012 218002 012 218002 012 42 Pump Retainer Sujetador De La Bomba ssssssssecssessesstessesssessnessnesseessesnseneesneeseess 110714 110714 110714 110714 43 Anti Flattening Coil Espiral Protectora cscsssssesssessesssessecsesssessnscsnessseseeeseseneeeeeeseens 110847 110847 110847 110847 44 Bleed OffKit Equipo De PUra eesssessecssscestesssesestecsseeesessueeenecsueesntessueeentecsneeenses 310586 310586 310586 310586 See the motor specification table Motor sold separately Vea la tabla de especificaciones del motor Motores se vende por separado 230V motor cord is optional and not supplied with cooler Cable el ctrico del motor de 230V es opcional y no se env a con el enfridor NOTE Standard hardware items may be purchased from your local hardware store NOTA Art culos de uso corriente pueden comprarse en la ferreter a de su localidad 18 110498 2 rn oc A AAA AASAD 19 EXPLODED ILLUSTRATION DOWN DISCHARGE CONFIGURATION ILUSTRACI N DE PIEZAS CONFIGURACI N DE DESCARGA DESCENDENTE 110498 2 PARTS LIST SIDE DISCHARGE CONFIGURATION LISTA DE PIEZAS CONFIGURACION DE DESCARGA LATERAL
37. motor inside cooler this will Pulley protect you from someone turning on unit while you are working inside This should be done for your safety Adjust pulley to a larger diameter and readjust belt tension Plug motor in install inspection panels and retest amperage draw BELT TENSION Repeat this process until correct amperage draw is attained Note Increasing motor pulley diameter increases 3 Lb Pressure amperage draw Decreasing motor pulley diameter 3 4 Inches decreases amperage draw NCAUTION DO NOT operate cooler with larger amperage draw than specified on motor plate Motor damage will occur 4 Check belt tension after adjusting pulley A 3 Ib force should deflect the belt 3 4 inches Readjust belt if A i Adjustment needed by loosening adjustment screw rotate motor Screw until you have the correct belt tension then re tighten screw OPERATION NOTES These coolers may be used without water for ventilation purposes When outside air is cool for example at night or when humidity is high the water pump can be turned off To eliminate the delivery of hot air when starting the cooler start the pump only for the first few minutes then turn on the blower motor For an evaporative cooler to be effective there needs to be adequate exhaust If there is not adequate exhaust pressure and humidity will build up in the building You exhaust by opening doors or windows to allow the old stale air in the building t
38. nciple Air is drawn across wet filter pads where the air is cooled by evaporation and then circulated throughout the building Itis this combination of cooled air and the movement of air over the skin which makes it feel cool Unlike refrigeration systems which recirculate the air an evaporative cooler continually brings in fresh air while exhausting old air You are completely replacing the air every 2 to 4 minutes by opening windows or doors by using Up Dux ceiling vents or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning PN 110498 2 REV 3 15 Read all instructions carefully Electrical connections should be done by a qualified electrician so that all electrical wiring will conform to your local codes Always turn OFF POWER and UNPLUG motor and pump inside the cooler before installing or performing any maintenance Your cooler will run on either 120V or 240V A C single phase 60 Hz cycle current Motor and pump have a grounded molded plug and an automatic thermal overload switch which will shut motor off when it overheats The motor will restart automatically when it cools down NWARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device Hot Outside Air enters unit and is water cooled When using ceiling vents attic stays cooler with duct work insi
39. o escape Attic exhaust dampers may also be installed to exhaust the air into the attic The combination of attic exhaust dampers and a thermostat can provide a completely automatic operation An often misunderstood concept of evaporative cooling is the amount of air that should be exhausted How much should you open your windows The following two methods will help you determine the amount to open your windows WINDOW AREA CFM METHOD For proper air flow allow an opening of at least 2 square feet 288 square inches for each 1000 CFM rating of your unit Example At 3320 CFM model ADA 51 1 2 hp requires 6 6 square feet 950 square inches of opening 3320 1000 2 6 6 Multiply the number of windows by window width in inches and divide this into the number of square inches required for your size unit This will give you the height to open windows In this example four 36 inch wide windows should be opened 6 6 inches each TISSUE SUCTION METHOD 1 Take a piece of tissue paper and cut it lengthwise into 3 equal strips 2 Turn your cooler on high cool 3 Open one window at least six inches wide in each room that you want to cool 4 Take the piece of tissue paper and put it up against the screen of the open window furthest from the cooler discharge opening Let go of it It will do one of three things IF It falls down THEN CLOSE all of the windows one inch and try step 4 again IF It plasters itself to the screen THEN OPEN all of
40. on the cabinet components Five 5 years on the evaporative media which is considered a disposable component and should be replaced periodically Two 2 years on the motor if furnished by Champion Cooler The manufacturer will replace the defective part product at its discretion It is agreed that such replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you Exclusions from this warranty We are not responsible for any incidental or consequential damage from any malfunction accident misuse alterations unauthorized repairs abuse including failure to perform reasonable maintenance normal wear and tear Alterations include the substitution of name brand components including but not limited to media pads We are not responsible for any damage from the use of water softeners or treatments chemicals or descaling materials We are not responsible for the cost of service calls to diagnose the cause of trouble or labor charge to repair and or replace parts No employee agent dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer The customer shall be responsible for all labor
41. ones el ctricas deben ser realizadas por un o TU 13 electricista calificado de manera que todo el cableado el ctrico M todo de Equilibrar el Aire 13 cumpla con sus mermas locales ManteniMiento vecinita 14 3 Siempre CORTE LA CORRIENTE y DESCONECTE al motor y sed la bomba dentro del enfriador antes de realizar la instalaci n o Tablas De Especificaciones 0 ns 15 mantenimiento Lista De Piezas De Repuesto 00 ne 17 4 Su enfriador funciona con corriente alterna de 120V o 240V Localizaci n de Aver as monofasica 60 Hz ciclos Garant a LiMitada ooococccicicinnncinnncnoncornecnrnocornonons 24 5 El motor y la bomba tienen un enchufe moldeado con descarga a tierra y un interruptor t rmico autom tico que apagar el motor en caso de sobrecalentamiento Los motores reiniciar n de forma autom tica al enfriarse Z ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilice este ventilador con ning n dispositivo de estado s lido de control de velocidad de ventilador COMO FUNCIONAN LOS op alre ame Al utilizar conductos de ventilaci n e exterior a la ENFRIADORES EVAPORATIVOS unidad y se enfr a enel techo el tico permanece SAAN gt por el agua m s fresco con los conductos El enfriamiento por evaporaci n es la forma natural de enfriar interior reducindo Cuando el aire se mueve sobre una superficie h meda el ensuin
42. onto the bleeder tubing to restrict the amount of water being bleed off The amount of water to bleed off depends on the quality of the water in your area Start with 1 2 gal hr and increase if needed AMPERAGE DRAW AND BELT TENSION Overflow Pipe Bleeder Tee Bleed Tube y T Restrictor Overflow Pipe NCAUTION No attempt should be made to completely install this unit without the aid of an electrician or someone familiar with testing amperage draw Failure to comply with these instructions may void your warranty This unit is eguipped with an adjustable motor drive pulley for adjusting the blower wheel speed to the proper loading for different duct systems Itis important that the motor drive pulley is adjusted to correct size to ensure maximum air delivery without damage to the motor Be sure to follow these instructions carefully 110498 2 AMPERAGE DRAW AND BELT TENSION CONT 1 Ensure electrical connection of unit is complete and in accordance with Motor all safety standards and local reguirements fille 2 Reinstall inspection panels Apply power turn water and pump on and Motor AN allow cooler to run for a few minutes to wet pads 5 saati A ecrease 8 Check amperage and verify it conforms to amperage listed on the Belt Amperage specification label on motor e If amperage draw is less than motor rating turn off electrical power ___ Blower and remove inspection panels Unplug
43. or manual switch installation 1 Determine location on internal wall for 6 position switch 2 Supply 120V or 240V power to switch depending on motor and pump Remove Screws to Access voltages Wiring Connections 3 Remove screws securing junction box to cooler cabinet Junction Box 4 Bring four conductors plus a ground from switch to cooler junction box such as two 2 wire Romex wire Motor And Pump i i Receptacles NCAUTION Make sure to use correctly sized wire and follow all local electrical codes 5 Connect the four conductor wires to the leads of the motor and pump Ti receptacles located in the junction box Follow the connection diagrams below for 120V or 240V installations 6 Reinstall junction box to cooler cabinet 7 Plug motor and pump plugs into receptacles 8 Follow switch electrical instructions for connecting the four conductors and power leads to switch Warning Pump cord must be secured in retaining clip to prevent contact with water 120 VOLT Blue Black PUMP White Brown e Orange e NOTE If single speed Green TO SWITCH motor is used do not A en use the RED electrical White COMMON leads from the motor or HIGH Orange e receptacle Tape off both LOW Green GROUND RED leads COMMON GROUND e WIRE NUT CAUTION Recepta cles in junction box are only for Motor and pump Do not plug anything ae 3 else into receptacle Brown gt PUMP Orange Green Black ie AWARNIN
44. polea del motor demasiado grande 3 Determine la causa Ajuste la tensi n de la correa Lubrique los cojinetes Aj stela al di metro correcto 4 Motor parado 1 Insuficiente abertura para que salga el aire 4 Cambie el motor 1 Abra ventanas o puertas para aumentar flujo de aire 2 Poca tensi n en la correa 2 Ajuste la tensi n o cambie la correa 3 Filtros obstruidos 3 Limpie los filtros 4 Motor no se carga 1 El flotador no se ajusta correctamente 4 Ajuste la polea 1 Ajuste el flotador 2 Montaje de desag e est goteando 1 Voltaje deficiente 1 Agua estancado en la unidad 1 Desag e y limpie el medio evaporativo 2 Apriete la tuerca y el tubo de desag e 1 Compruebe el voltaje 2 Demasiada tensi n en la correa 2 Ajuste la tensi n de la correa Motor se apaga y se enciende 3 Eje del ventilador atorado 3 Lubrique o cambie los cojinetes Desconecte la unidad 4 Cojinetes secos 4 Lubrique los cojinetes 5 Di metro demasiado grande de la polea del motor dando por resultado sobrecarga del motor 1 Cojinetes secos 5 Aj stela para no exceder el grado a carga plena del amperio del motor 1 Lubrique los cojinetes Hace Ruido 2 Rueda roza contra caja de la rueda 2 Inspeccione y alinee Desconecte la unidad 3 Partes sueltas Enfriamiento inadecuado Demasiada humedad en la casa 1 Insu
45. pulgada 3 Instale un extremo de la tuber a en la v lvula de agua colocando la Llave de Paso 4 Con Conexi n de tuerca y el f rula sobre el tubo y ajustando la tuerca hasta que sea a a Manguera est ndar prueba de agua INSTALACI N DE V LVULA DE FLOTADOR V ase la ilustraci n 1 Quite los elementos 1 2 3 y 4 del flotador 2 Inserte el cuerpo del flotador por el orificio en el escudo medio y el panel del poste trasero seg n muestra la figura 3 Aplique la arandela 1 y la tuerca 2 Ajuste para evitar que gire el flotador Coloque la tuerca 4 y el f rula 3 en la l nea de suministro de agua Conecte al conexi n roscada del flotador y ajuste hasta quedar a prueba de agua 4 Deslice el protector contra salpicaduras del flotador sobre el cuerpo del flotador hasta que encaje en su lugar Nota Una vez que termina la instalaci n y se enciende el agua ser necesario ajustar el nivel del flotador 5 Doble la vara para ajustar el flotador El nivel de agua deber a estar a una pulgada por debajo de la abertura del ca o de desag e INSTALACI N DE MONTAJE DE DESAG E 1 Quite la tuerca y coloque la boquilla por el orificio del panel con la junta de goma entre el panel y la cabeza de la boquilla 2 Atornille la tuerca a la boquilla y ajuste al panel inferior S Boquilla 3 Atornille el ca o de desag e a la boquilla Dicho ca o de desag e puede quitarse para drenar la fuente cuando sea necesario
46. que no tenga obstrucciones Reinstale la base de la bomba y confirme que est firme Antes de reinstalar la bomba revise la manguera de agua la l nea de purga y el tubo de distribuci n de agua para asegurarse de que no haya ninguna obstrucci n en las l neas Quite La Se O OV 14 110498 2 10 Reinstale la bomba deslizando la misma a la gu a de montura y reinsertando las abrazaderas pl sticas para asegurarse de que la bomba permanezca en posici n vertical 11 Vuelva a conectar el tubo de agua al pico de salida de la bomba REVISI N DE CORREA 1 Antes de encender la unidad verifique que la correa est en buenas condiciones En caso de que deba reemplazarla instale una correa del mismo tama o 2 Verifique que la tensi n sea correcta Desv o de 3 4 con 3 libras de fuerza APAGADO POR FINAL DE TEMPORADA Es necesario preparar el enfriador antes de todo per odo prolongado fuera de uso y en especial antes de ser apagado por el invierno 1 Quite toda el agua de la unidad la linea de suministro y la bomba para asegurarse que no haya da os por congelamiento Mantenga la l nea de agua desconectada de la unidad y del suministro de agua 2 Desconecte el motor y la bomba de la caja de conexiones 3 Limpie la unidad 4 Cubra la unidad para proteger el acabado durante per odos largos sin uso ESPECIFICACIONES GENERALES PESO libras DIMENSIONES DE GABINETE PULGADAS ABERTURA DE DUCTO SECO LLENO ALTURA ANC
47. seseneeenessneens 110714 43 Anti Flattening Coil Espiral Protectora cccsccssessessssssesssecsesssessnsesnessseseeesnsenessneesneens 110847 44 Bleed OffKit Equipo De PUra ssecsescssssessesssesssessesesessuecsncssessnssenesseesnsesneeneeeneesneees 310586 See the motor specification table Motor sold separately Vea la tabla de especificaciones del motor Motores se vende por separado 230V motor cord is optional and not supplied with cooler Cable el ctrico del motor de 230V es opcional y no se envia con el enfridor NOTE Standard hardware items may be purchased from your local hardware store NOTA Articulos de uso corriente pueden comprarse en la ferreteria de su localidad 22 AUA5112 322130 071 222130 075 322130 069 222130 073 222130 079 224130 002 222130 062 222130 063 222130 066 222130 067 324130 204 224003 015 218123 001 222130 078 322009 001 314003 011 314005 001 110372 8110372 2 110183 16BW 110275 110351 110393 110361 281045 002 281045 001 281033 001 3D 23 310118 001 110120 281042 001 310716 110610 FL C 281006 110429 218002 012 110714 110847 310586 AUA71 322140 054 222130 074 322140 052 222130 072 222140 058 224140 002 222140 045 222140 046 222140 047 222140 048 324140 204 224004 003 218001 038 222140 057 322009 001 314003 012 314005 001 110372 1 8110372 2 110183 20BW 110276 110351 110393 110361 281044 002 281044 001 2
48. sumo adicional de voltaje de la unidad NO se recomienda su instalaci n en el tico De instalar la unidad sobre el suelo aseg rese de que la zona est nivelada bien apisonada y que no sufrir erosi n o se tornar inestable al ser expuesta a l quidos e De instalar sobre un soporte o una construcci n existente aseg rese de que dicha estructura soportar el peso operativo del enfriador Vea la tabla de especificaciones para conocer el peso operativo e Aseg rese de que toda la unidad tenga soporte suficiente Si apoyar la unidad sobre pies en cada esquina debe agregar un apoyo en el medio de la unidad donde las dos secciones se unen Le recomendamos que consulte a un contratista profesional si la instalaci n requiere cortar estructuras existen tes tales como paredes o techos No atornille o perfore a 5 pulgadas del fondo de la secci n h meda ya que podr a atravesar el dep sito e Aseg rese de que el trabajo el ctrico cumpla con las normas locales Puede requerir un electricista para un cableado correcto y seguro NADVERTENCIA DESCONECTE TODOS LOS SERVICIOS EL CTRICOS QUE SE UTILIZAR N PARA ESTA UNIDAD ANTES DE COMENZAR LA INSTALACI N Y NO LOS RE CONECTE HASTA QUE FINALICE LA INSTALACI N PIEZAS Y HERRAMIENTAS NECESARIAS e Motor con polea para motor se adquiere por separado Llave Allen 5 32 para instalaci n de polea e Llave 7 16 o Llave ajustable Destornillador Phillips e
49. t 5 full turns to the least diameter 2 Install the motor pulley onto the motor shaft so that it aligns with the blower drive pulley and tighten with Allen wrench 3 Loosen adjustment screw on motor mount 4 Install belt onto pulleys 5 Rotate motor mount until belt is tight then tighten adjustment screw to secure belt Check belt tension per instructions on page 5 Note Further adjustment to belt and pulley may be required after installation is complete Remove Two Bolts e Each Side SC Connecting Wet And Blower Sections Remove Two Bolts Connecting Bottom Pans amp Ap Ap su Motor Clips M A kilet NN A Adjustable Motor Mount Adjustable Yoke ALIGN PULLEYS Motor Motor Pulley Belt ___ Blower Pulley Adjustment Screw 110498 2 ELECTRICAL CONNECTION NWARNING Electrical connections should be accomplished by a gualified electrician to ensure all electrical wiring conforms to local standards NWARNING Follow all safety precautions when working with electrical power NWARNING Before proceeding with installation ensure electrical power is disconnected until installation is complete Note This unit can be controlled with a manual 6 position switch found at a local hardware store or with a thermostat such as Champion s Masterstat Wall Control Thermostat model 110423 2 For thermostat installation refer to its operating manual Follow the steps below f
50. t belt tension or replace if needed Inadeguate air delivery with cooler running 3 Pads plugged dirty 3 Clean pads 4 Motor underloaded 4 Adjust pulley 2 Overflow assembly leaking 2 Tighten nut and overflow pipe 1 Low voltage 1 Check voltage 2 Excessive belt tension 2 Adjust belt tension 8 Blower shaft and tight or locked 3 Unplug unit and oil or replace bearings 4 Bearings dry 4 Oil bearings 5 Motor pulley diameter too large 5 Adjust pulley so full load ampere causing motor overload rating of motor is not exceeded 1 Bearings dry 1 Oil bearings 2 Wheel rubbing blower housing 2 Unplug unit inspect and realign 3 Tighten ose paris 1 Inadequate exhaust in house 1 Open windows or doors to increase air flow 2 Pads not wet 2 Check water distribution system e Pads clogged e Clean pads e Distribution tube holes clogged e Clean tube holes Pump not working properly e Unplug and replace or clean pump Excessive humidity in house 1 Insufficent air exhaust 1 Open doors or windows 110498 2 7 Motor cycles on and off Inadequate cooling MASTERCOOL SINGLE INLET LIMITED WARRANTY POLICY SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS This warranty is extended only to the original purchaser of this evaporative cooler when the unit is installed and used under normal conditions against defects in workmanship and materials as follows One 1 year from date of sale
51. te reemplazar la parte o producto defectuoso seg n lo crea conveniente Se acuerda que el reemplazo es la nica soluci n que el fabricante tiene disponible ASIMISMO HASTA EL GRADO M XIMO PERMITIDO POR LA LEY EL FABRICANTE NO SE HACE RESPONSABLE POR LOS DA OS DE CUALQUIER TIPO INCLUIDOS DA OS INCIDENTALES Y EMERGENTES O LA P RDIDA DE GANANCIAS O INGRESOS Algunos estados no permiten limitaciones con respecto a cu nto tiempo dura una garant a impl cita por lo tanto es posible que las limitaciones detalladas anteriormente no se apliquen a usted Exclusiones De Esta Garant a No nos responsabilizamos por cualquier tipo de da os accidentales o resultantes producto de cualquier tipo de mal funcionamiento accidente mal uso alteraciones reparaciones no autorizadas abuso incluidos la falta de mantenimiento razonable uso o desgaste normal Las alteraciones que puede sufrir el producto incluyen la sustituci n de componentes de marca incluido pero no limitado al medio evaporativo No nos responsabilizamos por cualquier da o provocado por el uso de suavizantes o tratamientos de agua qu micos o materiales de descalcificaci n No nos responsabilizamos por el costo de las llamadas al servicio para diagnosticar la causa del problema o el cargo de la mano de obra para reparar o reemplazar piezas Los empleados agentes distribuidores u otras personas no se encuentran autorizados a brindar garant as o condiciones en nombre del
52. uelo de papel y c rtelo a lo largo en 3 tiras iguales 2 Encienda su enfriador en High Cool enfriar alto 3 Abra una ventana por lo menos seis pulgadas de ancho en cada habitaci n que desea enfriar 4 Tome el trozo de papel y col quelo contra la superficie de la ventana abierta que est m s lejos de la abertura de desague del enfriador Suelte el papel Pueden ocurrir tres cosas SI Cae al suelo ENTONCES CIERRE todas las ventanas por lo menos una pulgada y pruebe nuevamente el paso 4 SI Se pega a la superficie ENTONCES ABRA todas las ventanas una pulgada y pruebe nuevamente el paso 4 SI Permanece ligeramente sobre la superficie ENTONCES PERFECTO Ya est todo listo Disfrute su enfriador Notas e Cuando cambie a Low Cool enfriar bajo debe volver a equilibrar su hogar Repita el paso 4 Una vez que equilibra su hogar puede enfriar algunas reas m s que otras abriendo m s esas ventanas y cerrando las otras en la misma proporci n Repita el paso 4 para asegurarse de que el aire de su hogar permanezca equilibrado 110498 2 13 MANTENIMIENTO Un mantenimiento peri dico de su enfriador mejorar su rendimiento y ampliar su vida til NADVERTENCIA Antes de realizar cualquier mantenimiento aseg rese de que la energ a est cortada y que el motor y la bomba est n desenchufados INICIO DE MANTENIMIENTO ESTACIONAL Realice los siguientes pasos b sicos antes de que las temperaturas hagan necesario

Download Pdf Manuals

image

Related Search

Related Contents

Presse - Mypety  FLEX Monoclonal Mouse Anti-Human BCL2 Oncoprotein  ELECTRONIC MULTI METER  The MISER Operator Manual    BENDIX BW7537 User's Manual  Saphira Software Manual  Kempoweld WIRE 400, 550  TX-SR313  Guía del usuario  

Copyright © All rights reserved.
Failed to retrieve file