Home
The Aqua Sub Jr. Operation Instructions
Contents
1. Pressure switch is pre set at the factory Improper adjustment of the pressure switch may cause severe overload or premature failure If the pump is subjected to rapid cycling during normal operation or infrequent periods damage may occur Battery Watering Technologies 6645 Holder Road Clemmons NC 27012 Phone 336 714 0448 Fax 336 714 0449 Free 877 522 5431 www batterywatering com Re order BWT AquaSub Jr Instructions BAMEN WATERING TECHNOLOGIES The leader in battery watering technology Manual de Instrucciones para el Cart Aqua Sub Jr Modelo NC5080P NC5080PN and NC5080PNMAN a Battery Watering Technologies Gracias por adquirir el Cart Aqua Sub Jr de suministro de agua de 8 galones de Battery Watering Technologies Por favor opere y mantenga su cart de suministro de agua de acuerdo con las instrucciones referidas a continuaci n Esta unidad se env a completamente ensamblada y tiene garant a de un a o desde la fecha de compra contra defectos de f brica o de mano de obra Su distribuidor autorizado es la mejor fuente de partes de repuesto y servicio Para obtener un servicio r pido y eficiente recuerde siempre dar la siguiente informaci n 1 Descripci n correcta de la parte y o n mero de la parte 2 Fecha de compra Carga de la bater a Cargue la bater a durante 8 10 horas antes de utilizar el tanque por primera vez o si ha estado almacenado por m s de 6 meses para asegurar que la unidad est c
2. batterywatering com EE Reordenar BWT AquaSub Jr Instructions BATTERY WATERING TECHNOLOGIES L der en Tecnolog a para Llenado de Bater as
3. power switch on the back of the system under the handle to ON and turn the direct fill link to ON 4 When the flow indicator stops spinning and all indicator eyes on top of the valves rise to the top turn the direct fill link OFF and disconnect the quick connects 5 Turn the pump OFF 6 Always disconnect the tank after watering Never leave it attached to the watering system 7 ALWAYS WATER AFTER CHARGING ALWAYS STORE THE SYSTEM IN A NON FREEZING ENVIRONMENT Troubleshooting Pump will NOT run 1 Check inline fuse on the wires on the pump If blown replace with new fuse 5 Amp mini blade fuse 2 Make sure BOTH on off switches are in the ON position power switches are located on the back of the unit and on the front of the pump under battery cover 3 Make sure your 12 volt source battery is fully charged 4 Insure a tight connection at the battery clips Pump runs but does not prime 1 Check line strainer screen at the inlet location at the tank You will need to unscrew the knurled nut to access this screen The tank should be empty while performing this otherwise you may have to tilt the tank backwards so water will be away from this inlet location 2 Periodically take the screen at this location out and clean it DO NOT USE PUMP IN AN EXPLOSIVE ENVIRONMENT WA RN N DO NOT USE TANK TO PUMP FLAMMABLE LIQUIDS GASOLINE KEROSENE FUEL OIL ETC PRESSURE SWITCH OPERATION
4. Instruction Manual for Aqua Sub Jr Model NC5080P NC5080PN and NC5080PNMAN Battery Watering Technologies Thank you for purchasing the Aqua Sub Jr 8 gallon water delivery cart from Battery Watering Technologies Please operate and maintain your watering cart according to the instructions below This unit ships fully assembled and is warranted for one year from date of purchase against manufacturer or workmanship defects Your authorized dealer is the best source of replacement parts and service To obtain prompt efficient service always remember to give the following information 1 Correct part description and or part number 2 Date of purchase Battery Charging Charge the battery for 8 10 hours before using the tank the first time or if it has been stored for more than 6 months to ensure that the unit is fully charged 1 Plug the charger into a 110 volt AC electric receptacle 2 Besure the power switch on the back of the system under the handle is in the OFF position 3 Insert the plug which is molded onto the end of the charger wire into the jack which is located on the rear of the tank 4 Disconnect the plug from the jack and the charger from the electrical outlet when the charging operation is complete Tank Operation 1 Fill the tank with clean or deionized water through the lid on top of the tank 2 Insert male connector from watering system into female connector on the direct fill link 3 Turn the
5. ompletamente cargada 1 Enchufe el cargador en un recept culo el ctrico de 110 voltios AC 2 Aseg rese de que el interruptor de encendido en la parte posterior del sistema debajo de la manija est en la posici n OFF 3 Introduzca el enchufe que est pegado en el extremo del cable cargador en el conector ubicado en la parte posterior del tanque 4 Desconecte el enchufe de la toma y el cargador del tomacorriente cuando la carga se haya completado O peraci n del tanque 1 Llene el tanque con agua limpia o desionizada a trav s de la tapa en la parte superior del tanque 2 Inserte el conector macho del sistema de suministro en el conector hembra en el conector de llenado directo 3 Gire el interruptor de encendido en la parte posterior del sistema debajo de la manija hacia ON y gire el conector de llenado directo hacia ON 4 Cuando el indicador de fluido deje de girar y todos los ojos indicadores en la parte superior de las v lvulas lleguen a la cima gire el conector de llenado directo hacia OFF y desconecte los conectores r pidas 5 Apague la bomba 6 Siempre desconecte el tanque despu s del suministro Nunca lo deje conectado al sistema de suministro 7 SIEMPRE SUMINISTRE AGUA DESPU S DE CARGAR ALMACENE SIEMPRE EL SISTEMA EN UN AMBIENTE SIN CONGELACI N Soluci n de problemas Si la bomba NO funciona 1 Revise el fusible en l nea en los cables de la bomba Si est quemado c mbielo por
6. un fusible nuevo fusible mini hoja de 5 Amp 2 Aseg rese de que AMBOS interruptores on off se encuentran en la posici n ON los interruptores se encuentran en la parte posterior de la unidad y en la parte frontal de la bomba bajo la cubierta de la bater a 3 Aseg rese de que su fuente de 12 voltios la bater a est totalmente cargada 4 Asegure una conexi n estrecha en los ganchos de la bater a Si la bomba funciona pero no se ceba 1 Revise la l nea de rejilla pantalla en el lugar de entrada en el tanque Usted tendr que desenroscar la tuerca para acceder a esta pantalla El tanque debe estar vac o mientras realiza esta operaci n de lo contrario es posible que tenga que inclinar el tanque hacia atr s para que el agua est lejos de esta entrada 2 Saque la pantalla de este lugar peri dicamente y limpiela NO UTILICE LA BOMBA EN UN AMBIENTE EXPLOSIVO NO USE EL ADVE RTE N CIA TANQUE PARA BOMBEAR LIQUIDOS INFLAMABLES GASOLINA QUEROSENO COMBUSTIBLE ACEITE ETC OPERACION DEL INTERRUPTOR DE PRESION El interruptor de presi n se coloca previamente en la f brica El ajuste inadecuado del mismo puede causar sobrecarga o falla prematura La bomba podr a da arse si se somete a ciclos r pidos durante el funcionamiento normal o a periodos poco frecuentes Battery Watering Technologies El El 6645 Holder Road Clemmons NC 27012 Tel 336 714 0448 Fax 336 714 0449 Servicio al Cliente 877 522 5431 www
Download Pdf Manuals
Related Search
Related Contents
1.28MB このたびは、モンバルをお買いあげいただき、ありがとうご USER MANUAL - AV Rev.01 - ONNTO Corporation Philips myLiving Spot light 53234/31/16 Service Manual, RBK 815 Bicycle.fm Samsung WA11BW/HC دليل المستخدم TOA Electronics C-DR161 User's Manual EUROLITE TC-300 User Manual Copyright © All rights reserved.