1. gt Donde xxxx son 16 caracteres como m ximo Ejemplo 07 2009 lt gt NAMTELMO lt CR gt P gina 3 ZI PROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO Proporciona la versi n de software SINTAXIS 2VER lt CR gt Respuesta VER STRING_VERSION CR gt Ejemplo 2VER lt CR gt VERv2 0 36 lt CR gt Define o proporciona los registros con la configuraci n de cada multiplex SINTAXIS Definir RGaabbcccccccccddddeeee lt CR gt Donde bb CCCCCCCC dddd Numero de registro o multiplex de 00 05 01 registro activo 00 registro inactivo Frequencia del canal en Hz Banda UHF Nivel umbral para el warning de potencia El n mero debe se un entero Entre 0 y 99 Unidades dBuV Nivel umbral para la alarma de potencia El n mero introducido debe se un entero Entre 0 y 99 Unidades dBuV Preguntar RGaa CR Respuesta RGaabbcccccccccddddeeee lt CR gt Ejemplo P gina 4 RG000165000000000850080 lt CR gt Configuraci n del primer registre 00 registre activo 01 Sintetiza la frecuencia 650 00 MHz 650000000 Umbral de potencia para warning 0085 Umbral de potencia para alarma 0080 07 2009 AXPROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO Define o proporciona la frecuencia SINTAXIS Definir FRTaaccccccccc lt CR gt
2. Proporciona la version de software SYNTAX 2VER lt CR gt Answer VER STRING_VERSION CR gt Example 2VER lt CR gt VERv2 0 36 lt CR gt 07 2009 Page 3 AxPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Defines or provides the general equipment set up SYNTAX Selection RGaabbcccccccccddddeeee lt CR gt Where bb cccccccc dddd Register or multiplex number from 00 to 05 01 Active register 00 inactive register Channel frequency in Hz UHF band Warning threshold level of Power The number must be a entire from 0 to 99 Units dBuV Alarm threshold level of Power The number must be a entire from 0 to 99 Units dBuV Inquiry RGaa lt CR gt Answer RGaabbcccccccccddddeeee lt CR gt Example RG000165000000000850080 lt CR gt First register set up 00 active register 01 frequency 650 00 MHz 650000000 Warning threshold level of power 0085 Alarm threshold level of Power 0080 Defines or provides the frequency SYNTAX Definition lt gt Where Register or multiplex number from 00 to 05 Channel frequencv in Hz UHF band Inquirv lt gt Answer lt gt Example 4 2FRTOO FRT650000000 lt CR gt First register inde
3. If the sent message requires response that one is sent after the ACKNOWLEDGE The answer should be finish by a CARRIAGE RETURN ODH After this command the TELMO will send a XON 11H meaning that is ready to receive another command It turns to step 2 Page 1 AxPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Example COMPUTER TELMO 1 PEN XON 2 NNAM CR w gt 3 PN XOFF 4 FEM ACK 5 NAMTELMO lt CR gt 6 WAIT 7 o XON all characters are transmitted in ASCII code Next are described the set of commands that TELMO accepts All commands are transmitted in ASCII code Page 2 07 2009 USER S MANUAL REMOTE CONTROL COMMANDS TELMO ARPROMAX 1 1 Remote commands index Comando remoto Breve descripci n Selects or provides the name of the equipment Provides the software version Defines or provides the set up registers for each multiplex Defines or provides the frequency Provides the MER measurement Provides the VBER measurement Defines or provides the general equipment set up Provides the POWER measurement Provides the equipment status active registers alarms and warnings 1 2 Remote commands description Selects or provides the name of the equipment SYNTAX Selection NAMxxxx lt CR gt Inquiry 2NAM lt CR gt Answer NAMxxxCR gt Where xxxx are 16 characters at the most Example 2NAM lt CR gt NAMTELMO lt CR gt
4. Donde aa N mero del registre o multiplex de 00 a 05 ccccccccc Frecuencia del canal en Hz Banda UHF Preguntar FRTaa lt CR gt Respuesta FRTccccccccc lt CR gt Ejemplo 2FRTOO FRT650000000 lt CR gt Index del primer registro 00 frecuencia 650 00 MHz 650000000 Proporciona la medida del MER SINTAXIS 2MERaa lt CR gt Respuesta MERbb bb lt CR gt Donde aa N mero de registro o multiplex de 00 a 05 bb bb Mesura del MER n mero con dos decimales y unidades en dB Ejemplo MEROO MER28 60 lt CR gt Medida del MER registre 00 MER 28 60cB Proporciona la medida del VBER SINTAXIS BERaa CR Respuesta BERb bbE 0c CR Donde aa Numero de registro o multiplex 00 a 05 b bbE Oc Medida del VBER numero con dos decimales y unidades dB Ejemplo BEROO BER1 00E 07 lt CR gt Medida del VER dos decimales y exponente VBER 1 00E 7 07 2009 Pagina 5 ZI PROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO Define o proporciona la configuraci n general del equipo SINTAXIS Definir CFGaaaabbbbc ccE Ode eeE 0f lt CR gt Preguntar 2CFG lt CR gt Respuesta CFGaabbccddeeff lt CR gt Donde aaaa c ccE 0d e eeE 0f Nivel umbral para la alarma de MER El n mero debe ser introducido en decimal unidades de la medida en dB s max 35 dB m n 0 dB Niv
5. 1 00E 02 Warning threshold level of VBER It must be a float number units 2 decimals and exponent e g 1 00E 02 Example 2CFG lt CR gt CFGO002200281 00E 011 00E 03 CR MER alarm 22dB MER warning 28dB VBER alarm 1 00E 1 VBER warning 1 00E 3 Provides the POWER measurement SYNTAX POWaa CR Answer POWbb bb lt CR gt Where aa bb bb Register or multiplex number 00 a 05 POWER measurement Example Page 6 2POWOO POW69 00 lt CR gt POWER measurement POWER 69 00 dBuV 07 2009 AXPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Provides the equipment status active registers alarms and warnings SYNTAX 2STT lt CR gt Answer STTaabbccdd lt CR gt Where aa Status HW HW OK 01 bb Active register mask All active Ox3F gt R6R5 R4R3R2R1 cc Alarm mask All activated Ox3F gt A6A5 A4A3A2A1 dd Warnings mask All activated Ox3F gt W6W5 W4W3W2W1 Example 2STT STT013F003F CR HW status OK all the registers are activated all the alarms are deactivated and all the warnings are activated 07 2009 Page 7 AxPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Page 8 07 2009 PROMAX ELECTRONICA S A C Francesc Moragas 71 75 08907 L HOSPITALET DE LLOBREGAT Barcelona SPAIN Tel 93 260 20 00 Tel Intl 34 93 260 20 02 Fax 93 338 11 26 Fax Intl 34 93 338 11 26
6. todas las alarmas desactivadas y todos los Warnings activos P gina 7 AxPROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO P gina 8 07 2009 AXPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO TABLE OF CONTENTS 1 COMMUNICATIONS PROTOCOL 1 1 1 Remote commands index eese enne nne sainia nne nnne 3 1 2 Remote commands 3 AxPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO users waua newore conmo comaosewo __ LESPROMAX REMOTE CONTROL COMMANDS TELMO 1 COMMUNICATIONS PROTOCOL Communication parameters are 115200 bits s 8 bits no parity and 1 bit STOP The communication is done via the USB port The communication protocol is 1 07 2009 TELMO periodically sends the code XON 11H to indicate that it is ready to receive a new command At this moment it can be sent a stream Each stream consists of a Stream beginning 2AH b Ifthe command is interrogative c Character set forming the remote command d CARRIAGE RETURN indicating the end of the message ODH Once the stream has been sent it is received an XOFF 13H indicating to stop the transmission Once completed the command it is sent an ACKNOWLEDGE 06H code in the case that the command had been interpreted correctly or NOT ACKNOWLEDGE 15H otherwise
7. TELMO COMANDOS CONTROL REMOTO REMOTE CONTROL COMMANDS KI AX PROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO ARPROMAX 1 PROTOCOLO DE COMUNICACI N 1 1 1 Indice de comandos remotos Lee eenennnnnnnn nanna nanna nr n anna 3 1 2 Descripci n comandos remotos nn nt 3 AxPROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO ZXPROMAX COMANDOS CONTROL REMOTO TELMO 1 PROTOCOLO DE COMUNICACION Los par metros de comunicaci n son 115200 bits s 8 bits no paridad y 1 bit de STOP La comunicaci n se realiza a trav s del puerto USB El protocolo de comunicaci n es 1 TELMO env a peri dicamente el c digo XON 11H para indicar que est preparado para recibir un nuevo comando 2 En este momento se le pueden enviar tramas Cada trama est compuesta por a Inicio de trama 2AH b Si el comando es interrogativo c Conjunto de caracteres que forman el comando remoto d CARRIAGE RETURN indicando el final del mensaje ODH 3 Una vez enviada la trama se recibe un XOFF 13H indicando que se pare la transmisi n 4 Una vez completado el comando se env a un c digo ACKNOWLEDGE 06H en el caso que el comando se haya interpretado correctamente o un NOT ACKNOWLEDGE 15H en caso contrario 5 Si el mensaje enviado requiere respuesta esta se env a a continuaci n del ACKNOWLEDGE Se h
8. a de acabar la respuesta con un CARRIAGE RETURN 6 Finalizada la comunicaci n de un comando el TELMO enviar un XON 11H indicando que ya est dispuesto para recibir otro comando 7 Pasamos al punto 2 07 2009 P gina 1 AxPROMAX Ejemplo todos los caracteres son transmitidos en c digo ASCII 1 2 3 4 5 6 7 COMPUTER 2NAM lt CR gt WATT MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO TELMO XON XOFF ACK NAMTELMO lt CR gt XON A continuaci n se describe el conjunto de comandos que acepta el TELMO Todos los comandos se transmiten en c digo ASCII P gina 2 07 2009 AXPROMAX MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO 1 1 indice de comandos remotos Comando remoto Breve descripci n Define o proporciona el nombre del equipo Proporciona la versi n de software Define o proporciona los registros con la configuraci n de cada multiplex Define o proporciona la frecuencia Proporciona la medida del MER Proporciona la medida de VBER Define o proporciona la configuraci n general del equipo Proporciona la medida de POWER Potencia Proporciona el status del equipo registros activos alarmas y warnings 1 2 Descripci n comandos remotos Define o proporciona el nombre del equipo SINTAXIS Definir NAMxxxx lt CR gt Preguntar lt gt Respuesta
9. el umbral para el warning del MER El n mero debe ser introducido en decimal unidades de la medida en dB s max 35 dB m n 0 dB Nivel umbral para la alarma de VBER El n mero debe ser introducido en float unidad dos decimales y exponente p e 1 00E 02 Nivel umbral para el warning de VBER El n mero debe ser introducido en float unidad dos decimales y exponente p e 1 00E 03 Ejemplo 2CFG lt CR gt CFG002200281 00E 011 00E 03 lt CR gt MER alarm 22dB MER warning 28dB VBER alarm 1 00E 1 VBER warning 1 00E 3 Proporciona la medida de POWER Potencia SINTAXIS POWaa CR Respuesta POWbb bb lt CR gt Donde aa bb bb N mero del registro o multiplex 00 a 05 Medida del POWER potencia dos unidades y dos decimales Ejemplo P gina 6 POWOO POW69 00 lt CR gt Medida del POWER 69 00 dBuV 07 2009 MANUAL DE INSTRUCCIONES COMANDOS CONTROL REMOTO TELMO ARPROMAX Proporciona el status del equipo registros activos alarmas v warnings SINTAXIS 2STT lt CR gt Respuesta STTaabbccdd lt CR gt Status HW HW OK 01 Mascara de registros activos Todos activos 0x3F gt R6R5 R4R3R2R1 M scara de alarmas Todas activadas Ox3F gt A6A5 A4A3A2AM M scara de warnings Todos activados Ox3F gt W6W5 W4W3W2W1 Ejemplo 07 2009 2STT STTO13FO003F CR Status HW OK todos los registros activos
10. http www promaxelectronics com e mail promax 0 promaxelectronics com
11. x 00 frequency 650 00 MHz 650000000 07 2009 AXPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Provides the MER measurment SYNTAX 2MERaa lt CR gt MERbb bb lt CR gt Answer Where bb bb Register or multiplex number from 00 to 05 MER measurement the number has two decimals and dB units 2MEROO MER28 60 lt CR gt MER measurement register 00 MER 28 60dB Example Provides the VBER measurement SYNTAX lt gt BERb bbE 0c lt CR gt Answer Where aa b bbE 0c Register or multiplex number from 00 to 05 VBER measurement the number has two decimals exponent and dB units BEROO BER1 00E 07 lt CR gt VBER measurement two decimals and exponents VBER 1 00E 7 Example 07 2009 Page 5 AxPROMAX USER S MANUAL REMOTE CONTROL COMMANDS TELMO Defines or provides the general equipment set up SYNTAX Selection CFGaaaabbbbc ccE Ode eeE 0f lt CR gt Inquiry 2CFG lt CR gt Answer CFGaabbccddeeff lt CR gt Where aaaa bbbb c ccE 0d e eeE 0f Alarm threshold level of MER It must be decimal number Measurement units dB max 35dB min OdB Warning threshold level of MER It must be a decimal number Measurement units dB max 35dB min OdB Alarm threshold level of VBER It must be a float number units 2 decimals and exponent e g