Contents

1. Indique el problema y ponga el m dulo de rel en un cart n bien acojinado y devu lvalo con el franqueo prepagado a Invensys Controls Americas Product Service Department 28C Leigh Fisher Blvd El Paso TX 79906 United States of America 111 329
2. CES THE MAXIMUM NUMBER OF INTERCONNECTED SMOKE ALARMS BY ONE INSTALLATION INSTRUCTIONS The relay module should be installed in a junction box All connections should be made by a qualified electrician in accordance with the requirements of the National Electric Code and or any local codes having jurisdiction 1 Turn off main power circuit 2 Install and wire your Firex smoke alarm as recommended in your smoke alarm owner s manual 3 Connect the black wires of the relay module and the smoke alarm to the black wire of the 120VAC line 4 Connect the yellow wire of the relay module to the yellow wire of the smoke alarm NOTE Connection of yellow wire to any voltage source greater than 20 volts will damage unit and void warranty 5 Connect the white wire of the relay module to the white wire of the smoke alarm 6 Connect the auxiliary device to the relay module contact leads as required Both normally open and normally closed contacts are available to control the auxiliary device NOTE The relay contact rating is 5 Amps max 120VAC or 28 VDC See NEC Article 725 52 for additional information on combining 120VAC circuits with low voltage Class 2 and Class 3 circuits 7 Cap any unused leads with a wire nut 8 Insert the relay module into the junction box and install the faceplate 9 Apply power to the circuit and test the smoke alarm and the auxiliary device for proper operation 10 See below for examples of wiring normally o
3. ETECTORES DE HUMO INTERCONECTADOS EN UNO INSTRUCCIONES PARA LA INSTALACION El m dulo de rel tiene que instalarse en una caja de conexiones Todas as conexiones tienen que ser hechas por un electricista calificado seg n los requisitos del C digo El ctrico Nacional y o seg n cualquier c digo local que tenga jurisdicci n 1 Apague la electricidad principal que va al circuito 2 Instale y cablee su alarma de humo Firex tal como se recomienda en su manual para el due o de la alarma de humo 3 Conecte los cables negros del m dulo de rel y el detector de humo con el cable negro de la l nea de 120 VCA 4 Conecte el cable amarillo del m dulo de rel con el cable amarillo del detector de humo AVISO La conexi n del cable amarillo con cualquier fuente de voltaje mayor de 20 volts da ar a unidad y anular la garant a 5 Conecte el cable blanco con el m dulo de rel al cable blanco del detector de humo 6 Conecte el dispositivo auxiliar con los conductores de contacto del m dulo de rel Tanto el contacto que est normalmente abierto como el que est normalmente cerrado est n disponibles para controlar el dispositivo auxiliar AVISO La capacidad del contacto de rel es de 5 amps m ximo a 120 VCA 0 28 VCC Vea el art culo NEC 725 52 para m s informaci n para la combinaci n de circuitos 120 VCA con voltaje bajo de circuitos clase 2 y clase 3 7 Termine los conductores no usados con una tuerca para cable 8 I
4. PIRE N TEE ER RELAY MODULE ITEM NO 499 INSTRUCTION MANUAL This manual contains instructions for installing your Firex Relay Module This relay module is U L listed as an accessory for use only with the Firex Smoke Alarm Nos 406 G 6 418 G 18 420 G 120 4418 AD 4480 PAD 4518 ADC 4580 FPAD 5000 4618 46182 FADC 5700 ADH 7000 FADCQ and is used to activate auxiliary devices All auxiliary devices to be activated shall be 120 Volt 60Hz 5 Amps maximum or 28 VDC 5 Amps maximum NOTE On the 7000 FADCQ Smoke CO Combo the 499 relay module will respond to the smoke alarm only It will not respond to the CO alarm WARNING This relay will not operate without continuous AC power Do not use with battery backup units CAUTION Do not interconnect Model No 499 to Models COQ8 FXW 1A FX1014 FX1020 FX1106 or any other manufacturer s units Doing so will permanently damage the relay Use your Firex Relay Module for Sirens Exit Signs Bells Warning Lights Fire Doors Exhaust Fans Visual Indicators The relay module is not recommended for use with automatic dialers or security alarm panels CAUTION THE RELAY MODULE IS NOT TO BE USED AS A METHOD OF EXTENDING THE MAXIMUM NUMBER OF SMOKE ALARMS PERMITTED IN MULTIPLE STATION OPERATION REFER TO SMOKE ALARM MANUAL FOR SPECIFIED MAXIMUM LIMIT EACH RELAY MODULE REPLACES ONE SMOKE ALARM LOAD IN AN INTERCONNECTED STRING THEREFORE USE OF THE RELAY REDU
5. con las alarmas de humo Firex Nos 406 G 6 418 G 18 420 G 120 4418 AD 4480 PAD 4518 ADC 4580 FPAD 5000 4618 46182 FADC 5700 ADH 7000 FADCO y se usa para activar los dispositivos auxiliares Todos los dispositivos auxiliares tienen que ser de 120 Volt 60Hz 5 amps m ximo o 28 VCC 5 amps m ximo para ser activados NOTA En 7000 FADOC combinaci n del CO del humo el m dulo 499 relay responder al alarmar del humo solamente No responder al alarmar del CO ADVERTENCIA Este rel no operar con corriente CA continua No lo use con unidades de repuesto con bater a PRECAUCION No interconecte el Modelo No 499 con los Modelos COQ8 FXW 1A FX1014 FX1020 FX1106 o con alguna otra unidad de otros fabricantes De lo contrario el rel sufrir da o permanente Use su m dulo de rel Firex para Sirenas se ales de salida timbres luces de advertencia puertas de incendio ventiladores de escape indicadores visuales No se recomienda usar el m dulo de rel con marcadores autom ticos o con paneles de alarma de seguridad PRECAUCION EL MODULO DE RELE NO SE DEBE USAR COMO UN METODO PARA EXTENDER EL NUMERO MAXIMO DE ALARMAS DE HUMO PERMITIDAS EN UNA OPERACION DE ESTACION MULTIPLE REFIERASE AL MANUAL DE LA ALARMA DE HUMO PARA UN LIMITE MAXIMO ESPECIFICADO CADA MODULO DE RELE REEMPLAZA UNA CARGA DE DETECCION DE HUMO EN UNA SERIE INTERCONECTADA POR LO TANTO EL USO DEL RELE REDUCE EL NUMERO MAXIMO DE D
6. e liable for any consequential damages for breach of this or any other warranty express or implied whatsoever Some states do not allow the exclusion of con sequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state Invensys Controls Americas 2005 NORMALLY CLOSED CONTACTS 120 VOLTS 60HZ 28 VOLTS D C pr rs o BLACK WHITE LOAD ON RELAY SHOULD NOT EXCEED 5 AMPS MAXIMUM AT 120 VOLTS 60HZ OR 28 VOLTS D C WHITE AUXILIARY DEVICE WHITE N C RED RELAY COMMON GRAY MODULE t N O BLUE YELLOW BLACK WIRE NUT JUNCTION BOX Ls y EXAMPLE OF WIRING TO NORMALLY CLOSED CONTACTS NOTE Relay does not supply 120 Volts to load This product is listed by UNDERWRITERS LABORATORIES INC and bears the mark Instructions for return State the trouble and place the relay module and proof of date of purchase in a well padded carton and return postage prepaid to Invensys o Controls Americas Product Service Department 28C Leigh Fisher Blvd El Paso TX 79906 United States of America 111 329 FIRE i o a _ MODULO DE RELE ITEM NO 499 MANUAL DE INSTRUCCIONES Este manual contiene las instrucciones para la instalaci n del m dulo de rel Firex Este m dulo de rel est en la lista de U L como un accesorio para uso solamente
7. es ma uso o abuso o por falta del cuidado razonable del producto Esta garantla se ofrece en lugar de todas las dem s garantlas expresas obligaciones o responsabilidades LAS GARANTIAS IMPLICITAS DE COMERCIALIZACION 0 DE ADECUACION PARA CUALQUIER USO EN PARTICULAR QUEDAN LIMITADAS AL PERIODO DE UN 1 ANO A PARTIR DE LA FECHA DE COMPRA Algunos estados no permiten limitaciones en cuanto al perlodo de tiempo que una garantla puede durar asi que puede ser que las limitaciones anteriores no se apliquen en su caso Por ning n motivo Climate Controls Americas ser responsable por ning n da o emergente debido al incumplimiento de sta o de ninguna otra garantla expresa o implicita Algunos estados no permiten la exclusi n de los da os emergentes asl que la exclusi n anterior puede ser que no se aplique en su caso Esta garantla le otorga derechos legales especlficos y tambi n puede tener otros derechos legales que pueden variar de un estado a otro CONTACTOS NORMALMENTE CERRADOS 120 VOLTS 60HZ 28 VOLTS CC P EL RELE DE CARGA NO DEBE EXCEDER gHEGRO BLANCO 5 AMPS MAXIMO A 120 VOLTS 60H2 O 28 VOLTS CC BLANCO AMARILLO MODULO S OMUN GRIS Ci NEGRO TUERCA DE CABLE EJEMPLO DE CABLEADO PARA LOS CONTACTOS NORMALMENTE CERRADOS AVISO El rel no suministra 120 volts para carga Este producto aparece en la lista de UL UNDERWRITERS LABORATORIES INC y lleva la marca Instrucciones para la devoluci n
8. nserte el m dulo de rel en la caja de conexiones e instale la placa delantera 9 Aplique la corriente al circuito y pruebe el detector de humo y el dispositivo auxiliar para verificar si la operaci n es adecuada 10 Vea los ejemplos a continuaci n para cablear circuitos normalmente abiertos o normalmente cerrados DIAGRAMAS DE INSTALACION 120 VOLTS 60HZ o 28 VOLTS CC NEGRO A BLANCO CONTACTOS NORMALMENTE ABIERTOS DETECTOR DE HUMO EL RELE DE CARGA NO DEBE EXCEDER 5 AMPS MAXIMO A 120 VOLTS 60HZ O 28 VOLTS CC j BLANCO BLANCO N C ROJO AMARILLO AMARILLO El 120 VOLTS 60HZ ENTRADA l TUERCA DE CABLE EJEMPLO DE CABLEADO PARA LOS CONTACTOS NORMALMENTE ABIERTOS AVISO El rel no suministra 120 volts para carga GARANTIA LIMITADA DE CLIMATE CONTROLS AMERICAS Climate Controls Americas garantiza al comprador original que el m dulo de rel Firex no tendr defectos ni en los materiales ni en la mano de obra por un 1 a o de servicio de uso normal a partir de la fecha de compra Climate Controls Americas se compromete a reparar o cambiar a su discreci n cualquier m dulo de rel Firex que se encuentre defectuoso siempre y cuando se devuelva a Climate Controls Americas con el franqueo prepagado y con la prueba de la fecha de compra Esta garantla no cubre ninguna bateria que se use en el pro ducto y cualquier da o resultante ni tampoco cubre da os producidos por acci dent
9. pen or normally closed circuits INSTALLATION DIAGRAMS NORMALLY OPEN CONTACTS 120 VOLTS 60HZ 28 VOLTS D C LOAD ON RELAY SHOULD NOT S MAXIMUM AT EXCEED 5 AMP EMOKE DETECTOR 120 VOLTS 60HZ OR 28 VOLTS D C l BLACK 120 VOLTS S0HZ INPUT EXAMPLE OF WIRING TO NORMALLY OPEN CONTACTS NOTE Relay does not supply 120 Volts to load CLIMATE CONTROLS AMERICAS LIMITED WARRANTY Climate Controls Americas warrants to the original consumer purchaser each new Firex relay module to be free from defects in material and workmanship under normal use and service for a period of one 1 year from date of purchase Climate Controls Americas agrees to repair or replace at its option any Firex relay module found defective provided that it is returned with postage prepaid and with proof of purchase date to Climate Controls Americas This warranty does not cover any battery which may be used in the product or any damage resulting there from nor does the warranty cover damage resulting from acci dent misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE ARE LIMITED TO A PERIOD OF ONE 1 YEAR FROM PURCHASE DATE Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you In no case shall Climate Controls Americas b