manual de instrucciones para uso y mantenimiento
Contents
1. NA DIMENSION DRAWING 25 03 2004 LISTA DE REPUESTOS ALTERNADOR G2R 315 tc lt z tc lt LO tc N CD kr tc lt LLI tc lt mn TECHNICAL DEP SA V ZEIT VIE 4 UI DIMENSION DRAWING 25 03 2004 LISTA DE REPUESTOS ALTERNADOR G2R 400 tc lt z tc lt o tc N CD kr tc lt tc lt mn N POTE EXTERNO NO SE USA PUENTEAR 6 Y 7 L2 IF POTENTIOMETER DON T EXISTS JOIN 6 AND 7 5 _ x POTENCIOMETRO EXTERNO PARA REGULAR TENSION OPCIONAL CLOCKWISE VOLTAGE REGULATION EXTERNAL POTENTIOMETER OPTIONAL V adj POTENCIOMETRO AJUSTE TENSION EXTERNO ROTACION HORARIA EXTERNAL VOLTAGE REGULATION POTENTIOMETER UF ADJ NO TOCAR EL POTENCIOMETRO AJUSTADO EN FABRICA DO NOT TOUCH THIS POTENTIOMETER TEST BENCH CALIBRATED REGULATOR 65 2 5 FUSIBLE g PARA TENSIONES MAYORES A 440 V CONECTAR TERMINAL 3 A DEL REGUADOR BORNE 5 Y TERMINAL 4 BORNE 7 FOR VOLTAGES HIGHER THAN 440 V CONNECT TERMINAL 3 OF THE AVR TO TERMINAL 5 AND 4 OF AVR TO TERMINAL 7 RECTIFICADOR CAMPO EXCITATRIZ EXCITER FIELD RECTIFIER EXCITATRIZ DBTs a DIAGRAMA CON
2. CREEN E R AM AC e G2R 250 280 315 63 7 1 TECHNICAL DEP REGULATOR 63 7 1A DATE DIMENSION DRAWING DIAGRAMA CONEXIONES SALIDA IZQUIERDA 19 10 9005 9 SLE 08Z 082 YZO L1 ROTACION HORARIA CLOCKWISE Transformador de corriente In 1A Curret transformer In 1A S1 Switch para operaci n en paralelo Abierto paralelo Cerrado un generador Single parallel switch Open parallel Close single 52 RECTIFICADOR RECTIFIER EXCITATRIZ EXCITER A lt N lt unido join 50 HZ 1 2 2 3 unido join 60 HZ CAMPO EXCITATRIZ EXCITER FIELD BOBINADO AUXILIAR AUXILIARY WINDING 1 FILTRO RF OPCIONAL RF FILTER OPTIONAL A N AMARILLO VERDE A V YELLOW GREEN CRAMACOo io a TECHNICAL DEP Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w ATENCION CONEXION GENERADORES DESDE 340 A 560 V PARA TENSIONES DE 170 A 280 V CAMBIAR SENSADO A El WARNING FOR 340 TO 560 Vac GENERATORS ONLY FOR 170 TO 280 CHANGE SENSING TO E1 DIAGRAMA CONEXIONES SALIDA DERECHA RIGHT OUTLET CONNECTION DIAGRAM 2 250 280 315 GRT7 TH4 R2 PART 340 560 V DATE DIMENSION DRAWING SPIES 11 09 06 VeVd V4 CH VH L ZL9 91
3. TRIFASICA A THREEPHASE AT Hz 50 380 415 220 240 190 208 MONOFASICA A SINGLE PHASE Hz 50 220 240 220 110 240 120 110 120 Hz 60 380 480 220 277 190 240 MONOFASICA SINGLE PHASE Hz 60 220 277 220 277 110 138 DIAGRAMA CONEXIONES SALIDA IZQUIERDA Tm dl DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION 22 7 SPES 31 10 2008 CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION G2R 200 63 7 1A SCALE TECHNICAL DEP VV 2 69 002 H29 L1 1 PARA MARCHA INDEPENDIENTE PUENTEAR BORNES 1 2 2 2 PARA MARCHA EN PARALELO ABRIR PUENTE 1 2 3 PARA GENERAR EN 60Hz ABRIR PUENTE 50 L3 4 SI SE DESEA AJUSTAR TENSION A DISTANCIA INTERCALAR ENTRE 7 6 UN POTENCIOMETRO 1 5kQ 2W Y ABRIR PUENTE 7 6 ROTACION HORARIA 5 EL POTE STAB SE CALIBRA EN BANCO NO TOCAR CLOCKWISE CAMPO EXCITATRIZ EXCITER FIELD A EXCITATRIZ EXCITER REGULATOR AVC 63 7 1A ESTATOR STATOR RECTIFIER RECTIFICADOR 5 amp gt lt 5 gt gt 5 lt e lt en O O FUSIBLE F 1 NON PARALLEL DUTY JOIN 1 2 2 PARALLEL DUTY OPEN 1 2 JUNCTION 60Hz DUTY OPEN 50 JUNCTION 4 FOR VOLTAGE REMOTE CONTROL INSERT BETWEEN 7 6 A 1 5 2W POTENTIOMETER AND OPEN 7 6 5 DO NOT TOUCH STAB
4. 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES ALTERNADORES SERIE G2R 12 TERMINALES Y TENSIONES POSIBLES ESTRELLA SERIE SERIE STAR CONNECTION CONNECTIONS CONEXIONES TRIFASICA THREEPHASE AT Hz 50 380 415 MONOFASICA A SINGLE PHASE AT Hz 50 220 240 TRIFASICA B THREEPHASE AT 2 60 380 480 MONOFASICA SINGLE PHASE Hz 60 220 277 CALIBRAR LA TENSION SEGUN LA CONEXION CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION DBTs a CRAMACOe DPTO TECNICO ESTRELLA PARALELO PARALLEL STAR CONNECTION 190 208 110 120 190 240 ATENCION para WARNING for 2 conectar 2 parallel alter 110 138 alternadores en nators 3 220 paralelo 3X220V double star see DIAGRAMA CONEXIONES SALIDA IZQUIERDA LEFT OUTLET CONNECTION DIAGRAM G2R 250 280 315 GRT7 TH4 R2 doble estrella ver drawing 19689 el plano 19688 DIBUJADO DIMENS EN PLANO SPIES 07 11 2006 N 1149 91 082 0420 DISPOSITIVO PARALELO PARA AVC 63 7 1A DOBLE ESTRELLA INSTRUCCIONES para el montaje del dispositivo de puesta en paralelo m quinas cuya conexi n corresponda a do ble estrella deber n solicitarse a f brica dos transformadores de corriente de relaci n adecuada para cada caso procediendo de la siguiente manera Colocar un transfor
5. nicamente personal autorizado 2 2 7 EXCITACI N Autom ticamente la m quina se autoexcita por imanaci n remanente debido a la conexi n serie de las excitatrices con el regulador el voltaje residual de estos generadores es mucho m s alto que en generadores sin excitatriz El valor de esta tensi n residual puede variar considerablemente y depende fundamentalmente de las propiedades del acero usado en el n cleo de la excitatriz Depende adem s l gicamente del estado de excitaci n anterior Por esto si debe ejecutarse alguna tarea en un generador brushless es absolutamente indispensable parar la m quina antes de realizar cualquier tarea La desconexi n del campo no es suficiente 2 3 REGULADOR DE TENSI N El regulador de tensi n debe Mantener constante la tensi n en los bornes del generador para marcha aislada independientemente de la carga y producir la ca da de tensi n necesaria para una correcta marcha en paralelo 3 Estabilizar la tensi n frente a fluctuaciones debida a variaciones de carga de corta duraci n La tensi n alterna trif sica del bobinado auxiliar es rectificada y transmitida en forma controlada al bobinado de la excitatriz Para las correspondencias entre modelos G2R y reguladores ver Tabla N 2 En todos los casos los reguladores cumplen las siguientes caracter sticas 2 3 1 FRECUENCIA Los reguladores pueden trabajar con 50 60 Hz Para cada regulador se dispone de indicaciones so
6. EXTERNAL VOLTAGE REGULATION POTENTIOMETER UF ADJ STAB NO TOCAR LOS POTENCIOMETROS AJUSTADOS EN FABRICA DO NOT TOUCH THESE POTENTIOMETERS TEST BENCH CALIBRATED RECTIFICADOR RECTIFIER EXCITATRIZ CRAMACOo TECHNICAL_DEP CAMPO EXCITATRIZ EXCITER FIELD DIAGRAMA CONEXIONES SALIDA IZQUIERDA LEFT OUTLET CONNECTION DIAGRAM G2R 200 AVC 63 4 AND V2 FUSIBLE INTERNO CON REPUESTO BUILT IN FUSE WITH SPARE UNIT REGULATOR 63 4 DATE DIMENSION DRAWING FISCHER 19 5 2004 9 002 ROTACION HORARIA SI EL POTE EXTERNO NO SE USA PUENTEAR L lt CLOCKWISE IF POTENTIOMETER DON T EXISTS JOIN LESH POTENCIOMETRO EXTERNO PARA REGULAR TENSION OPCIONAL VOLTAGE REGULATION EXTERNAL POTENTIOMETER OPTIONAL RECTIFICADOR RECTIFIER CAMPO EXCITATRIZ EXCITER FIELD Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w A EXCITATRIZ EXCITER BOBINADO AUXILIAR AUXILIARY WINDING 1 FILTRO RF OPCIONAL i RF FILTER OPTIONAL DIAGRAMA CONEXIONES SALIDA DERECHA RIGHT OUTLET CONNECTION DIAGRAM ERDE Ny NC GREEN G2R 200 GRT7 TH4 R2 4A S PAR 340 560 V SCALE TECHNICAL DEP YVdA S Vi CH VHL ZL89 006 YZO L1 ROTACI N HORARIA A
7. OPCIONAL VOLTAGE REGULATION EXTERNAL POTENTIOMETER OPTIONAL 1 2 unido join 50 2 3 unido join 60 CAMPO EXCITATRIZ RECTIFICADOR EXCITER FIELD RECTIFIER Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w EXCITATRIZ EXCITER A no E lt un lt 2 1 FILTRO RF OPCIONAL DATE DIMENSION DRAWING FILTER OPTIONAL DIAGRAMA CONEXIONES SALIDA DERECHA E 1 al A V AMARILLO VERDE A V YELLOW GREEN SCALE id uiii TECHNICAL WVd S Vv cu YHL ZLHO 005 091 ROTACION HORARIA SI EL EXTERNO NO SE USA PUENTEAR CLOCKWISE IF POTENTIOMETER DON T EXISTS JOIN POTENCIOMETRO EXTERNO PARA REGULAR TENSION OPCIONAL VOLTAGE REGULATION EXTERNAL POTENTIOMETER OPTIONAL CAMPO EXCITATRIZ RECTIFICADOR EXCITER FIELD RECTIFIER Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w A EXCITATRIZ EXCITER lt N 7 LE lt Lu 1 FILTRO RF OPCIONAL RF FILTER OPTIONAL 8 VERDE de rre did 160200 SIN AUX NO AUX WINDING Clo GRTT
8. POTENTIOMETER TEST BENCH CALIBRATED 1 FILTRO RF OPCIONAL ATE DIMENSION DRAWING RF FILTER OPTIONAL DIAGRAMA CONEXIONES SALIDA DERECHA 19 10 2005 PES RIGHT OUTLET CONNECTION DIAGRAM HN AMAN ODE CRAMACOe AVE 63T AA TECHNICAL DEP VV 2 69 GLE 08 096 HCO 11 1 PARA MARCHA INDEPENDIENTE PUENTEAR BORNES 1 2 iD 2 PARA MARCHA EN PARALELO ABRIR PUENTE 1 2 3 PARA GENERAR EN 60Hz ABRIR PUENTE 50 L3 4 SI SE DESEA AJUSTAR TENSION A DISTANCIA INTERCALAR ENTRE 7 6 UN POTENCIOMETRO 1 5kQ 2W Y ABRIR PUENTE 7 6 ROTACION HORARIA 5 EL POTE SE CALIBRA EN BANCO NO TOCAR CLOCKWISE CAMPO EXCITATRIZ EXCITER FIELD A EXCITATRIZ EXCITER 1 5K 2 W EXT POT RECTIFIER RECTIFICADOR CD e z z amp 221 4 gt e gt lt 5 7 4 s 5 lt 2 iz ce lt z FUSIBLE F 1 NON PARALLEL DUTY JOIN 1 2 2 PARALLEL DUTY OPEN 1 2 JUNCTION 3 60Hz DUTY OPEN 50 JUNCTION 4 FOR VOLTAGE REMOTE CONTROL INSERT BETWEEN 7 6 A 1 5kQ 2W POTENTIOMETER AND OPEN 7 6 5 DO NOT TOUCH STAB POTENTIOMETER TEST BENCH CALIBRATED 1 FILTRO RF OPCIONAL RF FILTER OPTIONAL LEFT OUTLET CONNECTION DIAGRAM i I
9. tres fases Esta regla es v lida para todas las m quinas independientemente de su capacidad o tensi n y a n cuando la m quina ha sido dise ada para girar en el sentido contrario de las agujas del reloj Si gira en sentido contrario la secuencia cambia a VUW 3 7 3 La autoexcitaci n autom tica es independiente del sentido de giro 4 VERIFICACIONES PARA LA PUESTA EN SERVICIO 4 1 INSPECCIONES 4 1 1 Antes de poner en servicio el generador despu s del montaje para su ensayo de rotaci n o despu s de un largo per odo de parada fuera de servicio la m quina debe limpiarse concienzudamente Retirar cualquier material residual del embalaje que pudiera quedar adherido a la m quina 4 1 2 El generador debe ser anclado adecuadamente a la fundaci n 4 1 3 Eliminar todos los elementos de fijaci n colocados para el transporte 4 1 4 Asegurarse que todas las piezas del acoplamiento est n posicionadas correctamente y que las instrucciones de mantenimiento hayan sido observadas 4 1 5 Verificar y confirmar que todas las conexiones el ctricas se han realizado seg n los diagramas suministrados con la m quina Confirmar que la conexi n de las borneras del generador es la correcta 4 1 6 Si el grupo tiene ajustador de control remoto instalado verificar su instalaci n correcta 4 1 7 Verificar que los terminales que conectan a la red est n correctamente acomodados y fijados en la caja de bornes de manera tal que impida
10. 208 110 120 190 240 ATENCION para WARNING for 2 conectar 2 parallel alter 110 138 alternadores en nators 3X220V paralelo 3X220V double star see DIAGRAMA CONEXIONES SALIDA IZQUIERDA LEFT OUTLET CONNECTION DIAGRAM G2R 250 280 315 AVC 63 7 1A doble estrella ver drawing 19689 el plano 19688 Ja VV 9 DAY SLE 082 0402 ALTERNADORES SERIE 628 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES 2 ALTERNATORS SERIES IN 12 WIRES CONFIGURATION CONNECTIONS AND VOLTAGES POSSIBILITIES ESTRELLA SERIE SERIE STAR CONNECTION ESTRELLA PARALELO PARALLEL STAR CONNECTION CONEXIONES CONNECTIONS TRIFASICA m THREEPHASE AT Hz 50 580 415 MONOFASICA A SINGLE PHASE Hz 50 220 240 TRIFASICA A THREEPHASE AT Hz 60 380 480 MONOFASICA A SINGLE PHASE Hz 60 220 277 CALIBRAR LA TENSION SEGUN LA CONEXION CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION 190 208 110 120 190 240 ATENCION para WARNING for 2 conectar 2 parallel alter alternadores en nators 3X220V 110 138 paralelo 3X220V double star see doble estrella ver drawing 19689 V el plano 19688 DATE DIMENSION DRAWING DIAGRAMA CONEXIONES SALIDA DERECHA SPES 07 11 2006 RIGHT OUTLET CONNECTION DIAGRAM G2R 250 280 315 GRT7 TH4 R2 SCALE YHL 1139 GLE 082 086 YZO ALTERNATORS G2R SERIES
11. 5 086 056 469 L1 ROTACION HORARIA CLOCKWISE S1 Switch para operaci n en paralelo Abierto paralelo Cerrado un generador Single parallel switch ansformador de corriente In 1A Open parallel Close single urret transformer In 1A 1 2 unido join 50 2 3 unido join 60 RECTIFICADOR RECTIFIER 9 CAMPO EXCITATRIZ EXCITER FIELD Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w EXCITATRIZ EXCITER A Mi Ga Vi N N ATENCION CONEXION PARA GENERADORES DESDE 340 A 560 V PARA BOBINADO AUXILIAR TENSIONES DE 170 A 280 V CAMBIAR SENSADO A El AUXILIARY WINDING WARNING FOR 340 TO 560 GENERATORS ONLY FOR 170 TO 280 CHANGE SENSING TO E1 1 FILTRO RF OPCIONAL DATE DIMENSION DRAWING RF FILTER OPTIONAL DIAGRAMA CONEXIONES SALIDA IZQUIERDA SPES 10 10 LEFT OUTLET CONNECTION DIAGRAM MN I DC GREEN E R AM AC e G2R 250 280 315 GRT7 TH4 R2 7A PAR1 340 560 V SCALE TECHNICAL DEP LHYd YZ ZH YHL ZLY9 615 085 086 ALTERNADORES SERIE G2R 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES G2R ALTERNATORS SERIES IN 12 WIRES CONFIGURATION CONNECTIONS AND VOLTAGES POSSIBILITIES ESTRELLA SERIE SERIE STAR CONNECTION CONEXIONES CONNECTIONS TRIFASICA x THREEPHASE A
12. 50 380 415 220 240 190 208 MONOFASICA A SINGLE PHASE AT Hz 50 220 240 220 110 240 120 110 120 220 110 240 120 EA w heso 20 27 MONOFASICA SINGLE PHASE Hz 60 220 277 220 277 110 138 220 110 277 138 DIAGRAMA CONEXIONES SALIDA DERECHA CALIBRAR LA TENSION SEGUN LA CONEXION al YO WW AG CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION G2R 200 63 4 SCALE DPTO TECNICO 9 008 429 ALTERNADORES SERIE G2R A 12 TERMINALES Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES CONNECTIONS lt a TRIFASICA THREEPHASE AT MONOFASICA A SINGLE PHASE AT Hz 50 Hz 50 380 415 220 240 190 208 220 240 220 110 240 120 110 120 220 110 240 120 TRIFASICA A THREEPHASE AT Hz 60 580 480 220 277 190 240 MONOFASICA SINGLE PHASE Hz 60 220 277 220 277 110 138 220 110 277 138 CALIBRAR LA TENSION SEGUN LA CONEXION CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION 7 DATE DIMENSION DRAWING N DBTs DIAGRAMA CONEXIONES SALIDA IZQUIERDA 24 8 2006 LEFT OUTLET CONNECTION DI
13. ADO 220V P 220V SENSING JOIN V1 AGE REMOTE CONTROL BOBINADO AUXILIAR AUXILIARY WINDING V adj POTENCIOMETRO AJUSTE TENSION EXTERNO EXTERNAL VOLTAGE REGULATION POTENTIOMETER UF ADJ STAB NO TOCAR LOS POTENCIOMETROS AJUSTADOS EN FABRICA DO NOT TOUCH THESE POTENTIOMETERS TEST BENCH CALIBRATED RECTIFICADOR RECTIFIER EXCITATRIZ CRAMACOe TECHNICAL DEP CAMPO EXCITATRIZ EXCITER FIELD REGULATOR 63 4 DIAGRAMA CONEXIONES SALIDA DERECHA RIGHT OUTLET CONN G2R 200 AV ECTION DIAGRAM 63 4A EN UE AND V2 OPTIONAL TEAR FUSIBLE INTERNO CON REPUESTO BUILT IN FUSE WITH SPARE UNIT DRAWING N 9 006 469 L3 CLOCKWISE SENTIDO HORARIO SI EL POTE EXTERNO NO SE USA PUENTEAR 6 Y 7 JOIN 6 AND 7 IF THE VOLTAGE REMOTE CONTROL DONT WORKS 2 50 HZ DUTY JOIN HZ1 60 HZ DUTY LEAVE HZ1 HZ1 HZ2 PUENTEADO PARA 50HZ ABRIR PARA 60 HZ AND HZ2 AND HZ2 SEPARATED POTENCIOMETRO EXTERNO PARA REGULAR TENSION OPCIONAL VOLTAGE REMOTE CONTROL POTENTIOMETER OPTIONAL PAS V1 V2 PARA SENSADO 220V PUENTEAR 220V SENSING JOIN 1 BOBINADO AUXILIAR AUXILIARY WINDING V adj POTENCIOMETRO AJUSTE TENSION EXTERNO
14. AGRAM RAM AC G2R 200 AVC 63 4A DPTO TECNICO 9 006 469 ALTERNADORES SERIE G2R A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES CION para CONNECTIONS conectar 2 alternadores en paralelo 3X220V doble estrella ver el plano 19688 WARNING for 2 parallel nators 3X220V double star see drawing 19689 TRIFASICA THREEPHASE AT 2 50 380 415 220 240 190 208 MONOFASICA A SINGLE PHASE AT heso 220 240 220 110 240 120 110 120 60 580 480 220 277 190 240 MONOFASICA SINGLE PHASE Hz 60 220 277 220 277 110 138 DIAGRAMA CONEXIONES SALIDA DERECHA A TE DIMENSION i DRAWINGN CALIBRAR LA TENSION SEGUN LA CONEXION eones CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION G2R 200 AVC 63 7 1A SCALE TECHNICAL DEP 2 59 008 ALTERNADORES SERIE G2R A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES 7 4 10 O OU 8 5 WM O ov 9 6 1 O O OW CONEXIONES ATENCION para CONNECTIONS conectar 2 AVC alternadores en paralelo 3X220V doble estrella ver el plano 19688 WARNING for 2 parallel alter nators 3X220V double star see drawing 19689
15. CALE TECHNICAL DEP 1 9 002 091 ALTERNADORES SERIE G2R A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES E2 E3 4 CONNECTIONS CRT7 TH4 R0 44 E1 23 4 5 4 GRT7 TH4 R2 44 GRT7 TH4 R2 44 GRT7 TH4 R2 44 10 4 10 U oO OU 8 lt Q 8 5 11 ZO V O ov 6 3 12 9 12 G O O W ow TRIFASICA A THREEPHASE AT P 2 50 380 415 220 240 190 208 MONOFASICA SINGLE PHASE heso 220 240 220 110 240 120 110 120 220 110 240 120 TUN ue 380 480 20 27 pus MONOFASICA A SINGLE PHASE AT Hz 60 220 277 220 277 110 138 220 110 277 138 DATE DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION 03 11 2006 CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION G2R 160 200 GRT7 THA R2 4A SCALE TECHNICAL DEP Vi c VH I ZL89 002 091 29 SENTIDO HORARIO SI EL POTE EXTERNO NO 5 HZ1 2 50 HZ2 PUENTEADO 50 60 POTENCIOMETRO EXTERNO PARA R E USA PUENTEAR 6 Y 7 6 AND 7 IF THE VOLTAGE REMOTE CONTROL DON T WORKS HZ ABRIR PARA 60 HZ 2 DUTY JOIN HZ1 AND HZ2 2 DUTY LEAVE HZ1 AND HZ2 SEPARATED EGULAR TENSION OPCIONAL VOLT N V1 V2 PARA SENS
16. CRAMACO REV 3 MANUAL DE INSTRUCCIONES PARA USO Y MANTENIMIENTO M QUINAS SINCR NICAS SERIE G2R 160 200 250 280 315 400 CUATRO POLOS SIN ESCOBILLAS 1 GENERAL Estas instrucciones tienen por objeto servir al personal encargado de instalar conectar y mantener el generador Adem s se dan instrucciones sobre subconjuntos por si deben realizarse trabajos de reparaci n Estos generadores cumplen con las normas IEC 60034 VDE 0530 C51 100 111 y 112 BS 4999 5000 pudiendo cumplimentarse otras especificaciones que no estuvieran previstas si se requiere en el momento de la orden de producci n 2 INTRODUCCI N AL ESTUDIO DE M QUINAS SINCR NICAS G2R 2 1 CONSTRUCCI N El generador se puede dividir en varios componentes que cubren diversas funciones como se describe en los p rrafos siguientes 2 1 1 M QUINA PRINCIPAL 2 1 1a Estator La carcasa del estator esta realizada en una estructura de acero soldada El n cleo de hierro laminado con el bobinado se aloja en la carcasa Los alambres de las bobinas estat ricas se insertan uno a uno en las ranuras de forma semicerrada La aislaci n de las bobinas responde a las especificaciones de la clase H Las bobinas se fijan firmemente en su posici n con cu as de material aislante que cierran las ranuras Las bobinas est n estrechamente ligadas para resistir vibraciones tensiones mec nicas e impactos Los terminales de las bobinas se conectan a los bornes sin conductores inter
17. CRIPCI N Lista de repuestos G2R 160 Lista de repuestos G2R 200 Lista de repuestos G2R 250 Lista de repuestos G2R 280 Lista de repuestos G2R 315 Lista de repuestos G2R 400 Diag de conexiones derecha G2R 200 160 AVC 63 2 5 Diag de conexiones izquierda G2R 200 160 AVC 63 2 5 Diag de conexiones derecha G2R 200 160 GRT7 TH4 R2 S PAR Diag de conexiones izquierda G2R 200 160 GRT7 TH4 R2 S PAR Variantes de tensiones derecha G2R 200 160 AVC 63 2 5 Variantes de tensiones izquierda G2R 200 160 AVC 63 2 5 Variantes de tensiones derecha G2R 200 160 GRT7 4 R2 Variantes de tensiones izquierda G2R 200 160 GRT7 TH4 R2 Diag de conexiones derecha G2R 200 AVC 63 4 Diag de conexiones izquierda G2R 200 AVC 63 4A Diag de conexiones derecha G2R 200 GRT7 TH4 R2 Diag de conexiones izquierda G2R 200 GRT7 TH4 R2 Variantes de tensiones derecha G2R 200 AVC 63 4A Variantes de tensiones izquierda G2R 200 AVC 63 4 Variantes de tensiones derecha G2R 200 AVC 63 7 1A Variantes de tensiones izquierda G2R 200 AVC 63 7 1A Diag de conexiones derecha G2R 250 280 315 AVC 63 7 1A Diag de conexiones izquierda G2R 250 280 315 AVC 63 7 1A Diag de conexiones derecha G2R 250 280 315 GRT7 TH4 R2 Diag de conexiones
18. EXIONES SALIDA DERECHA NL ER men RIGHT OUTLET CONNECTION DIAGRAM CRAMACOe G2R 160 200 AVC 63 2 5 220 440 V TECHNICAL DEP S 2 9 DAY 006 091 YZO V L1 L2 L3 CLOCKWISE ROTACION HORARIA N SIE E EXTERNO NO SE IF ENTIOMETER DON T EX IN POTENCIOMETRO EXTERNO PARA REGU AL POTENTIOMETER OPTIONAL VOLTAGE REGULATION EXTER USA PUENTEAR 6 Y 7 STS JOIN 6 AND 7 LAR TENSION 0 V adj POTENCIOMETRO AJUSTE TENSION EXTERNO EXTERNAL VOLTAGE R EGULATION POTENTIOMET UF ADJ NO TOCAR EL POTENCIOMETRO AJUSTADO E DO NOT TOUCH THIS POTENTIOMETER TEST BENCH CALIBRATED RECTIFICADOR CAMPO EXCITATRIZ EXCITER FIELD RECTIFIER EXCITATRIZ TECHNICAL DEP OF THE AVR G2R 160 200 AVC 63 2 5 220 440 V REGULATOR 63 2 5 PARA TENSIONES MAYORES A 440 V CONECTAR TERMINAL 3 WA DEL REGUADOR BORNE 5 Y TERMINAL 4 A BORNE 7 FOR VOLTAGES HIGHER THAN 440 V CONNECT TERMINAL 3 TO TERMINAL 5 AND 4 OF AVR TO TERMINAL 7 DATE DIAGRAMA CONEXIONES SALIDA IZQUIERDA FISCHER 9 5 2005 LEFT OUTLET CONNECTION DIAGRAM 8 40 69 002 091 ROTACION HORARIA N SI EL EXTERNO NO SE USA PUENTEAR LE CLOCKWISE IF POTENTIOMETER DON T EXISTS JOIN LE POTENCIOMETRO EXTERNO PARA REGULAR TENSION
19. OU 5 11 O ov 6 12 oW TRIFASICA THREEPHASE AT Hz 50 220 240 190 208 MONOFASICA A SINGLE PHASE Hz 50 220 240 220 110 240 120 110 120 220 110 240 120 Lit aa 380 480 220 277 190 240 MONOFASICA A SINGLE PHASE Hz 60 220 277 220 277 110 138 220 110 277 138 DATE DIMENSION DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION e CONEXIONES SALIDA IZQDIERDO19065 10 10 2006 LEFT OUTLET CONNECTION DIAGRAM TECHNICAL DEP S Z 9 008 HO 091 ALTERNADORES SERIE G2R A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES 2 3 4 ET E3 A ET E3 A 3 4 CONNECTIONS T M RO M RT M R M ORT M R M i 4 1 7 UG O 2 8 5 VO O O 3 9 6 9 6 Wo O o 2 WO O O O TRIFASICA A THREEPHASE AT 2 2 50 380 415 220 240 190 208 MONOFASICA A SINGLE PHASE AT heso 220 240 220 110 240 120 110 120 220 110 240 120 WE 04 2 27 MONOFASICA SINGLE PHASE 2 60 220 277 220 277 110 138 220 110 277 138 D DATE DIMENSION DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION SAE SPES 03 11 2006 CALIBRATE THE VOLTAGE ACCORDING THE CONNECTION a GRIA HA RO 4A S
20. S E TECHNICAL DEP v 5600 c Oi YVd S Vr 1 0 002 091 YZO ALTERNADORES SERIE 2 A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES 4 3 3 4 3 4 CONNECTIONS AVC63 25 AMC63 25 AVC63 2 5 4 1 7 UO O 2 8 5 VO 3 9 6 WO O TRIFASICA A THREEPHASE AT Hz 50 380 415 220 240 190 208 MONOFASICA A SINGLE PHASE 2 50 220 240 220 110 240 120 110 120 220 110 240 120 AT 380 480 220 277 190 240 MONOFASICA SINGLE PHASE 2 60 220 277 220 277 110 138 220 110 277 138 DIAGRAMA CONEXIONES SALIDA DERECHA fE DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION GH OUTLET CONNECTION DIAGRAN SPES 18 10 2006 CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION 2 a O SCALE TECHNICAL DEP S C 9 00Z HO 091 V ALTERNADORES SERIE 2 A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES 3 4 3 4 2204 3 4 CONNECTIONS N063 25 AVC63 2 5 53 25 AC63 25 4 10
21. SI EL POTE EXTERNO NO SE USA PUENTEAR LES CLOCKWISE IF POTENTIOMETER DON T EXISTS JOIN LESH POTENCIOMETRO EXTERNO PARA REGULAR TENSION OPCIONAL VOLTAGE REGULATION EXTERNAL POTENTIOMETER OPTIONAL RECTIFICADOR RECTIFIER CAMPO EXCITATRIZ EXCITER FIELD Ajuste de voltaje externo 5kQ 3w Voltage external adjust 5kQ 3w EXCITATRIZ EXCITER no LE lt lt ta A A Vv 6d TES BOBINADO AUXILIAR AUXILIARY WINDING 1 FILTRO RF OPCIONAL DATE DIMENSION DRAWING RF FILTER OPTIONAL DIAGRAMA CONEXIONES SALIDA IZQUIERDA 552 LEFT OUTLET CONNECTION DIAGRAM A 4 On ERDE DC GREEN e R A M AC G2R 200 GRT7 TH4 R2 4 S PAR 340 560 V SCALE TECHNICAL DEP WVd S Vi cHd vH1 21H9 002 469 ALTERNADORES SERIE G2R A 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ALTERNATORS G2R SERIES IN 12 WIRES CONFIGURATION POSSIBILITY OF CONNECTIONS AND VOLTAGES CONEXIONES E3 E Ei El CONNECTIONS AVC63 44 AVC63 4A AVC63 4A ES El AVC63 4A 1 4 7 4 10 N OO 8 5 2 8 5 VO OOo O v 9 6 12 3 W 9 6 12 TRIFASICA THREEPHASE AT Hz
22. T Hz 50 580 415 MONOFASICA A SINGLE PHASE AT Hz 50 220 240 TRIFASICA A X THREEPHASE AT Hz 60 580 480 MONOFASICA SINGLE PHASE Hz 60 220 277 ESTRELLA PARALELO PARALLEL STAR CONNECTION 190 208 110 120 190 240 ATENCION para WARNING for 2 conectar 2 parallel alter alternadores en nators 3X220V 110 138 paralelo 3X220V double star see doble estrella ver drawing 19689 V el plano 19688 DATE DIMENSION DRAWING CALIBRAR LA TENSION SEGUN LA CONEXION DIAGRAMA CONEXIONES SALIDA DERECHA SPES 07 11 2006 RIGHT OUTLET CONNECTION DIAGRAM CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION G2R 250 280 315 AVC 63 7 SCALE TECHNICAL DEP VV 9 9 082 OSZ ALTERNATORS G2R SERIES 12 WIRES CONFIGURATION 55 OF CONNECTIONS AND VOLTAGES ALTERNADORES SERIE G2R 12 TERMINALES CONEXIONADO Y TENSIONES POSIBLES ESTRELLA SERIE SERIE STAR CONNECTION CONNECTIONS CONEXIONES TRIFASICA Es THREEPHASE AT Hz 50 580 415 MONOFASICA SINGLE PHASE 2 50 220 240 TRIFASICA A THREEPHASE 2 60 380 480 MONOFASICA A SINGLE PHASE AT Hz 60 220 277 CALIBRAR LA TENSION SEGUN LA CONEXION CALIBRATE THE VOLTAGE ACCORDING TO THE CONNECTION DBTs a CRAMACOe DPTO TECNICO ESTRELLA PARALELO PARALLEL STAR CONNECTION 190
23. ador Borne de conexi n UV W Protecci n salida de aire lado Conjunto rectificador rotante completo accionamiento B2 Protecci n salida de aire lado Portafusible accionamiento B3 B14 Protec salida de aire lado acc IP23 B2 Fusible Protecci n salida de aire lado Regulador de Tensi n accionamiento IP23 B3 B14 Caja bornes completa Arandela ret n interior B3 B14 Cubo acoplamiento B2 Arandela ret n exterior B3 B14 G2R 400 Discos acoplamiento B2 Arandela laberinto B3 B14 G2R 400 Tap n pasa cable Ver planos G2R 160 N 19751 G2R 200 N 19752 G2R 280 N 19753 G2R 315 N 19754 G2R 400 N 19755 IMPORTANTE A cada pedido de repuesto se debe indicar el modelo y el N de m quina EJEMPLO Ventilador para G2R 315 SA 4 N 31324 3248 Repuesto N 007 PLANTA INDUSTRIAL y ADMINISTRACION Rivadavia 1701 2440 SASTRE Pcia Santa Fe Argentina T E 0054 3406 480074 FAX 0054 3406 480007 e mail dbt dbtsa com ar http www dbtsa com ar E TN gt Member of Q Federatior RINA pee PERIODO DE GARANTIA El per odo de garant a para alternadores es de doce meses desde que la m quina est lista para ser despachada y el lugar de recepci n o entrega es en nuestra planta DEFECTOS POSTERIORES A LA ENTREGA Se reparar n o reemplazar n alternadores dentro del per odo de garant a si fueron utilizados instalados o almacenados en forma correcta o
24. ados El ventilador esta montado del lado del accionamiento El aire entra a trav s de la rejilla de lado excitatriz e impulsado a trav s de esta y generador principal para salir por las rejillas del lado acoplamiento El ventilador es del tipo radial tal que el sentido de giro es indistinto 2 2 PERFORMANCE DE TRABAJO 2 2 1 PRECISI N Y TIEMPO DE REGULACI N DE LA TENSI N La tensi n de salida en condiciones estacionarias tiene una precisi n de 0 5 en cualquier condici n de factores de potencia comprendidos entre O sobreexcitados y 1 y es independiente de la temperatura del generador 2 2 2 SOBRECARGA Los generadores est n dise ados para cumplir con las normas de sobrecargas sin sobrecalentamientos pero bajo estas condiciones de sobrecarga no es posible garantizar la precisi n establecida de la regulaci n de la tensi n Cuando se conectan motores es permisible una sobrecarga doble de la corriente nominal por no m s de 20 segundos Aumentar los valores nominales de potencia de un generador mediante la admisi n de aire de refrigeraci n a menor temperatura que la fijada es nicamente aceptado mediante acuerdo previo con el fabricante 2 2 3 CORTOCIRCUITO Si se produce un cortocircuito franco en los bornes principales del generador tendremos inicialmente la m xima corriente de cortocircuito Su valor de pico es independiente del sistema de excitaci n La corriente de cortocircuito que continuar s depende del siste
25. bien debido a fallas de fabricaci n o traslado Todas las identificaciones y n meros deber n estar intactas para hacer efectiva la garant a No nos hacemos responsables por el costo que se podr a ocasionar en remoci n o colocaci n de cualquier parte o alternador enviados a nosotros para inspecci n o debido a un reemplazo No nos hacemos responsables por defectos de nuestros productos que han sido reparados alterados o ajustados por personal ajeno a la empresa No nos hacemos responsable por alternadores de segunda mano o bien art culos no construidos aunque suministrados por nosotros estos ltimos ser n regidos por sus respectivas garant as si las tuviesen Todos los reclamos por alternadores deber n contener una detallada descripci n del defecto el n mero de serie fecha de la compra nombre y direcci n del vendedor En el caso de partes de repuesto se deber hacer referencia a la factura del mismo Nuestro juicio ser definitorio en la resoluci n de cualquier reclamo y el reclamante deber aceptar nuestra decisi n en lo concerniente a los defectos e intercambio del alternador o parte en cuesti n Nuestra responsabilidad ser absuelta por completo reparando o reemplazando como se describe anteriormente y en caso de que la garant a no se hiciera efectiva en ning n caso se exceder de la lista de precios actual para el reemplazo Nuestras cl usulas ser n puestas en lugar de cualquier garant a o condici n im
26. bre la forma de pasar de una frecuencia a otra ver Tabla 1 Adem s poseen compensaci n para baja frecuencia regulables y que mantienen la relaci n U F aproximadamente constante 2 3 2 TENSI N La m quina puede trabajar en diferentes tensiones y frecuencias El esquema de conexiones y tensiones as como las disposiciones f sicas se observan en los respectivos planos Tabla N 2 En la Serie G2R 400 por tener tensiones a pedido nicamente tienen validez los planos entregados con cada m quina junto al protocolo de ensayos MUY IMPORTANTE De ser necesario cambios en las tensiones para obtener el nuevo valor de tensi n de debe respetar los planos y luego de esto ajustar con m quina en marcha el pote incorporado al regulador e identificado como VOLTS 2 3 3 FUSIBLE En los cables de alimentaci n se conecta un fusible acorde las indicaciones de la Tabla N 1 MUY IMPORTANTE En caso de manipuleo de fusible hacerlo siempre con la m quina detenida 2 3 4 AJUSTE DE TENSI N INCORPORADO Un potenci metro interno identificado como VOLTS permite el ajuste de la tensi n 2 3 5 AJUSTE DE ESTABILIDAD Es posible con pote interno similar al anterior No obstante el mismo ya fue calibrado en banco de prueba y solamente se permite su modificaci n mediante la presencia del personal autorizado 3 VERIFICACIONES PREVIAS AL MONTAJE Est secci n suministra informaci n sobre desembalaje inspecci n almacenaje fundaci n
27. ciente usar agentes de limpieza que no afecten la aislaci n Se aconseja uso de solventes de uso el ctrico con secado a temperatura ambiente 6 5 1 3 REV 3 Los generadores que cubren servicios de emergencia stand by deben ponerse en carga durante 2 a 3 hs peri dicamente no dejando transcurrir m s de 2 a 3 meses dependiendo ello de la humedad ambiente 5 2 Las m quinas tienen cojinetes standard sellados y prelubricados que no requieren mantenimiento Deben ser reemplazados despu s de 20 000 horas de trabajos o en caso de ruidos o temperaturas anormales 6 LISTADO DE FALLAS M S FRECUENTES 6 1 Tensi n del generador oscila Fallas Verificaciones Soluciones La velocidad del motor var a Revisar regulador de velocidad del motor 6 2 El generador no se autoexcita El magnetismo residual es muy bajo La velocidad del motor no es la correcta El circuito principal del excitaci n esta interrumpido El varistor est destruido Falla en el regulador 6 3 El generador no alcanza al voltaje nominal Los rectificadores rotantes est n destruidos La velocidad del motor no es la correcta Fusible sobre el borne 3 del regulador quemado Falla en el regulador Verificaciones Soluciones Aplicar una excitaci n externa bornes mediante bater a desde 5 hasta 12 V y hasta que la tensi n de salida se incremente autom ticamente NOTA Si se usa la bater a de arranque d
28. e un arrollamiento auxiliar cuya tensi n generada sirve para alimentar el regulador de tensi n en marchas normales y cortocircuitos 2 1 4 TIPOS DE PROTECCI N La ejecuci n normal es IP20S IP23S DIN 40050 Otros tipos bajo pedido 2 1 5 FORMA CONSTRUCTIVA El generador trif sico tipo G2R sin escobillas brushless est formado por la m quina principal en la cu l se incluye el bobinado auxiliar una excitatriz de c a trif sico con rectificadores rotantes y un regulador de voltaje est tico 2 1 6 CAJA DE BORNES Est ubicada en la parte superior del alternador del lado excitatriz La entrada de los cables puede hacerse indistintamente de izquierda o derecha La caja de bornes contiene la bornera principal y el regulador 2 1 7 SISTEMA DE ACOPLE RODAMIENTO La serie G2R ha sido desarrollada de tal manera de lograr indistintamente un acoplamiento a uno o dos cojinetes sin necesidad de desmontar la m quina Un simple cambio de tapa permite tener una configuraci n B3 B14 o B2 a excepci n de la Serie G2R 400 que es bajo pedido A su vez dentro de la posibilidad B2 est n previstas todas las posibilidades de SAE Volante Cubrevolante que usualmente requiere el mercado de los motores diesel Adem s bajo pedido puede hacerse acoplamientos especiales Los rodamientos utilizados son del tipo prelubricado y sellado tal que no se requiere reengrase durante el funcionamiento 2 1 8 VENTILACI N Los generadores son autoventil
29. el diesel desconectar el borne a masa Ajustar la velocidad Verificar conexiones Desconectar el varistor y verificar Reemplazar el regulador y enviarlo al fabricante Verificaciones y Soluciones Verificar los diodos y reemplazar si es Ajustar la velocidad Cambiar fusible 6 4 Reemplazar el regulador El generador entrega en vac o al voltaje nominal pero cae la tensi n en carga Los rectificadores rotantes est n destruidos La velocidad cae demasiado Verificaciones y Soluciones Verificar los diodos y reemplazar si es necesario 6 5 Revisar regulador de velocidad del motor Cae la tensi n a cero estando el generador a tensi n nominal Actu protecci n de sobreexcitaci n Verificaciones Soluciones Detener la m quina verificar fusible Poner en marcha y verificar si se autoexcita Falla en el regulador Reemplazar el regulador 7 LISTA DE REPUESTOS ALTERNADORES G2R 160 200 250 280 315 y 400 Repuesto Descripci n Repuesto Descripci n Carcaza con estator Rodamiento lado accionamiento B3 B14 Rotor principal Rodamiento lado excitatriz Rotor excitatriz bobinado Bornera salida potencia completa Estator excitatriz Bornera 3 bornes Escudo lado accionamiento B2 Bornera 6 bornes Escudo lado accionamiento B3 B14 Puente bornes neutro Escudo lado excitatriz Puente bornes media fase Ventil
30. i n 1A y se conectan seg n planos de conexionado Para las m quinas 3 x 220 V doble estrella se incorporan dos transformadores seg n plano correspondiente En el momento de trabajo de paralelo la distribuci n correcta de la corriente activa depende solamente del control del motor de accionamiento en cambio la distribuci n de la carga reactiva es una funci n de las condiciones de excitaci n que prevalecen en el generador Esto puede modificarse por variaciones del ajustador de tensi n de referencia que el cliente puede intercalar seg n el plano correspondiente Tabla 22 Resulta evidente que cuando se utiliza la ca da de tensi n reactiva la precisi n de 0 5 de la tensi n de salida no es v lida IMPORTANTE Para todos los casos de marcha en paralelo se recomienda utilizar el siguiente procedimiento A Verificar la existencia y funcionamiento de la protecci n de potencia inversa B Habilitar la resistencia de ca da reactiva C Previo a la primer maniobra de puesta en paralelo igualar el valor de la tensi n del generador con el de las barras mediante el pote incorporado al regulador e identificado como VOLTS sentido horario para incrementar o con el ajuste de tensi n de referencia a distancia si lo tuviera D Una vez en carga si el valor del factor de potencia es menor al nominal se debe corregir variando la resistencia de ca da reactiva E En estas condiciones el generador deber asumir sucesivos trabajo
31. izquierda G2R 250 280 315 GRT7 R2 Variantes de tensiones derecha G2R 250 280 315 63 7 1A Variantes de tensiones izquierda G2R 250 280 315 AVC 63 7 1A Variantes de tensiones derecha G2R 250 280 315 GRT7 TH4 R2 Variantes de tensiones izquierda G2R 250 280 315 GRT7 4 R2 Instrucciones para montaje de disp de paralelo Instructions for parallel circutry assembling NUMERO DE PLANO 19751 19752 A 20058 19753 19754 19755 19486 A 19487 A 20035 20036 19488 A 19489 A 20059 20060 19492 A 19493 A 20008 A 20034 19494 A 19495 A 19496 C 19497 C 19498 B 19499 B 19794 A 20037 19500 C 19501 C 20061 20062 19688 C 19689 C 559 NS in SPARE PARTS G2R 160 ALTERNATOR es os 2004 a CRAMACO LISTA DE REPUESTOS SCALE 19751 TECHNICAL DEP ALTERNADOR G2R 160 K SPARE PARTS G2R 200 ALTERNATOR 25 03 2004 CRAMACO LISTA DE REPUESTOS SCALE 19752 A TECHNICAL DEP ALTERNADOR G2R 200 w 1 0 05 DIMENSION DRAWING SPARE PARTS G2R 250 ALTERNATOR 25 03 2004 20058 LISTA DE REPUESTOS SCALE TECHNICAL DEP ALTERNADOR G2R 250 1 0 05 1 DIMENSION DRAWING 25 03 2004 LISTA DE REPUESTOS ALTERNADOR G2R 280 tc lt z tc lt o 99 N tc N CD kr tc lt LLI tc lt mn CRAMACO TECHNICAL DEP
32. ma de excitaci n El sistema de excitaci n utilizado en los generadores hace que la corriente en cortocircuito prolongados sea mayor de dos veces y medio del valor nominal Como tiempo m ximo admisible de cortocircuito debe tomarse 3 segundos 2 2 4 TRABAJOS EN PARALELO Todos nuestros generadores tienen bobinado amortiguador y consecuentemente pueden trabajar en paralelo con la red o con otros generadores Adem s en principio sincronizaciones defectuosas deben ser evitadas ya que pueden da ar la m quina se han previsto protecciones para los rectificadores contra estas fallas pero es imposible alcanzar una total seguridad Si se requiere un neutro com n para operar con un sistema en paralelo necesitan una reactancia en el punto neutro la que puede ser omitida si el voltaje de las fases de los generadores en paralelo o de la l nea est n libres de arm nicas o si nicamente se usan generadores id nticos en paralelo La series G2R 160 G2R 200 y G2R 250 no incluye el equipamiento para la puesta en paralelo Si es necesario puede agregarse bajo pedido Para este caso se debe consultar a f brica Adem s deber n observarse las siguientes prescripciones 2 2 4 2 TRABAJO EN PARALELO CON RED ver planos correspondientes para cada caso 2 CRAMACO REV 3 En esta forma de operaci n a fin de obtener una ca da de tensi n dependiente de la carga reactiva un transformador estabilizador se incorpora a la fase W Tiene una relac
33. mador de corriente en componen la fase W entre bornes 6 y 3 una de las ramas que o 12 y 9 entrando por el lado designado con K desde el estator hacia la bornera Colocar un transformador de corriente en componen la fase U entre bornes 4 y lado opuesto al designado con K desde el Conectar los cables designados con K ent regulador de tensi n una de las ramas que o 10 y 7 entrando por el estator hacia la bornera re s y al borne 2 del Conectar los cables designados con L entre s y al borne 1 del regulador de tensi n Desconectar el transformador de corriente en caso de ser posible retirarlo existente y cortocircuitarlo DBTs a INSTRUCCIONES PARA EL MONTAJE DEL PLANO N SPIES 13 11 2006 DISPOSITIVO DE PUESTA EN DPTO TECNICO MAQUINAS CON CONEXI N EN PARALELO EN DOBLE ESTRELLA TA
34. medios evitando empalmes y con ello la posibilidad de malos contactos 2 1 1 b Rueda Polar La rueda polar aloja las bobinas de excitaci n Los n cleos polares est n formados por laminaciones apiladas Una jaula induce el efecto amortiguador para el caso de cargas desequilibradas y trabajos en paralelo Las bobinas est n soportadas en sus extremos por barras axiales y en los huecos entre los polos acu adas mediante mordazas especiales dise adas para contrarrestar el efecto de la fuerza centr fuga 2 1 2 EXCITATRIZ 2 1 2 a Estator Es un generador de c a trif sico del tipo de armadura rotante Est fijado al escudo del lado excitatriz de la m quina El estator laminado forma los polos que sostienen las bobinas de campo de esta excitatriz 2 1 2 b Rotor La armadura de esta excitatriz esta montada en el eje de la m quina fabricada con laminaciones finas de chapa El bobinado en alambre esmaltado es trif sico con neutro no accesible y alimenta un conjunto rectificador compuesto de seis diodos conectados en puente estrella Estos diodos est n montados de a tres en dos placas disipadoras una y otra aisladas el ctricamente entre ellas y a masa Cada placa se conecta a los terminales de los bobinados de excitaci n de la rueda polar y en paralelo entre ellas se instala un protector de sobretensi n 2 1 3 BOBINADO AUXILIAR DE EXCITACI N A excepci n de los alternadores de la serie G2R 160 y los G2R 200 SAA se dispone d
35. n fogonazos o cortocircuitos 4 1 8 Verificar la puesta a masa del generador 4 1 9 Verificar la resistencia de aislaci n de todos los bobinados con un meg hmetro de 500 a 1000 Volt valor m nimo de aislaci n 1 Este control debe efectuarse sobretodo en puestas en marcha luego de un largo per odo con la m quina detenida 4 2 ARRANQUE Despu s de que todas las inspecciones han sido completadas satisfactoriamente el generador est listo para la primera puesta en servicio Cuando gira hasta alcanzar la velocidad nominal va excitando su campo Alcanzada la velocidad nominal esta listo para trabajar y poner bajo carga 4 3 AJUSTE DE TENSI N En el banco de prueba el fabricante ensay el generador ajustando la tensi n de salida al valor requerido por la orden de compra Una calibraci n posterior en el lugar de trabajo no es necesaria salvo para la primer maniobra de puesta en paralelo Ver p rrafo 2 2 4 4 4 GENERADORES QUE TRABAJAN AISLADOS Los reguladores que tienen posibilidad de marcha independiente o paralelo se despachan salvo pedido de acuerdo a lo indicado en la Tabla N 2 4 5 GENERADORES TRABAJANDO EN PARALELO Ver p rrafo 2 2 4 5 VERIFICACIONES DE MANTENIMIENTO 5 1 Es necesario peri dicamente quitar del generador el polvo aceite y suciedad que puede haberse acumulado en su interior 5 1 1 Realizar estas tareas con la m quina parada 5 1 2 Si la limpieza en seco no es sufi
36. principales U V W 3 5 2 Conectar el conductor neutro al terminal N 3 5 3 S lo los planos provistos con el generador tienen validez y comprometen al fabricante Referirse a estos planos para ubicar los terminales bornera y elementos que se indican en este manual 3 5 4 Lubricar ligeramente con vaselina los terminales que conectan los bornes del generador con la l nea y ajustar fuertemente los tornillos y tuercas a la bornera 3 5 5 Disponer los cables y conductores de manera que la distancia entre ellos y la caja sea la m xima posible 3 5 6 Conectar la masa a tal fin se utiliza uno de los agujeros de fijaci n 3 6 ACOPLAMIENTO 3 6 1 Usar solamente acoplamientos con superficie de contacto bien mecanizada El acople debe transmitir solo momento torsor y no transmitir ninguna componente de otro sentido 3 6 2 Asegurar que cuando se acopla el generador al motor de accionamiento por medio de acople r gidos o el sticos la l nea que pasa por el eje geom trico de ambos sea una recta es decir que debe lograrse una perfecta alineaci n de la m quina 3 7 SENTIDO DE GIRO 3 7 1 El generador puede funcionar indistintamente en ambos sentidos de giro 3 7 2 Seg n las normas de aplicaci n los bornes del generador est n marcados en orden alfab tico cuando el sentido de giro es el de las agujas del reloj mirando desde el lado del accionamiento los terminales UVW concuerdan con la secuencia cronol gica de las
37. puestas por terceros como especificaciones o locaciones particulares no nos hacemos responsables por da os o p rdidas causadas debido a esta situaci n as como de alternadores o partes da adas debido a esto Para m s informaciones cont ctese con nuestro Departamento de Asistencia t cnica 63 2 5 2 W Auto Auto TABLA 1 PRINCIPALES CARACTER STICAS DE LOS REGULADORES 250 V AVC 63 4 10k0 2W Puente HZ1 HZ2 Abierto HZ1 HZ2 6 3A 250V AVC 63 7 1A 1 5 2 W Puente 50 COM Abierto 50 COM 250 V GRT7 TH4 R2 4A S PAR 3 W Puente JHz 1 2 Puente JHz 2 3 5 A 250 V GRT7 TH4 R2 7A PAR1 3 W Puente JHz 1 2 Puente JHz 2 3 250 V GRT7 TH4 R2 7A E9 PAR1 3 W Puente JHz 1 2 Puente JHz 2 3 10 250 V G2R 160 AVC 63 2 5 19486 19487 GRT7 TH4 R2 4A S PAR 20035 20036 AV 4 19492 19493 A G2R 200 C 63 9492 9493 GRT7 TH4 R2 4A S PAR 20008 A 20034 AV 7 1A 19498 B 19499 B G2R 250 C 63 9498 9499 GRT7 TH4 R2 7A 1 19794 A 20037 AV 7 1A 19498 B 19499 B G2R 280 C 63 9498 9499 GRT7 R2 7A PARA 19794 A 20037 315 AVC 63 7 1 19498 19499 GRT7 TH4 R2 7A 1 19794 20037 AV 71A G2R 400 GRT7 R2 7A 1 Conexiones seg n plano provisto con m quina INDICE DE PLANOS DES
38. s en paralelo SIN MODIFICAR NINGUN ELEMENTO DE CONTROL salvo variaciones anormales en las barras a los cuales se conecta 2 2 4 b PARALELO AUTOM TICO CON REPARTIDOR DE CARGA REACTIVA En este tipo de operaci n el reparto de carga reactiva es realizado autom ticamente por un controlador electr nico Este tipo de dispositivos son compatibles solamente con reguladores con entradas anal gicas de 9 V implementadas a tal fin y provistas s lo bajo pedido 2 2 5 ELIMINACI N DE INTERFERENCIAS RADIALES Si no se requiere expresamente los generadores cumplen con el grado G establecidos en las normas L gicamente los generadores pueden suministrarse a pedido con grados m s elevados N o K de dicha norma La conexi n de estos dispositivos de filtro est n incorporados en el diagrama de conexi n interna provisto con la m quina Cuando se mida la resistencia de aislaci n es necesario desconectar estos condensadores 2 2 6 AJUSTE DE TENSI N DE REFERENCIA Los generadores tienen previsto la conexi n de un potenci metro externo que permite variar la tensi n de salida dentro del 5 Para detalles de conexi n y valores de los potenci metros ver Tabla N 1 Este ajuste puede montarse sobre la misma caja de bornera o bien a distancia en el tablero de comando del equipo Se suministra solo bajo pedido y para generadores que funcionan en paralelo se recomienda bloquearlo luego de la primer maniobra Ver p rrafo 2 2 4 teniendo acceso
39. ubicaci n alineaci n conexiones el ctricas acoplamiento y direcci n de rotaci n 3 1 RECEPCI N 3 1 1 Una vez recibido el generador verificar prolijamente sino se produjeron da os durante el transporte Si se verificara alguna lesi n del embalaje informar de inmediato a la Compa a de Transporte y al fabricante al fin de permitir a este realizar el reclamo correspondiente a la Compa a de Seguro 3 1 2 Las eslingas deben sujetarse en las agarraderas para transporte del generador y en ning n caso por el eje La descarga y emplazamiento deben realizarse cuidadosamente evitado golpes o impactos 3 2 ALMACENAMIENTO 3 2 1 Debe evitarse el almacenaje en lugares abiertos o h medos 3 2 2 A fin de evitar improntas en las pistas de rodamientos elegir un lugar libre de vibraciones o aislar la m quina de las mismas Girar peri dicamente el rotor 3 3 FIJACI N PARA EL TRANSPORTE Para las m quinas construidas con un solo cojinete B2 se despachan con elementos de fijaci n que unen la brida con los discos de acoplamiento CRAMACO REV 3 3 4 UBICACI N Emplazar el generador en un lugar con buena admisi n de aire limpio y fresco El recinto debe ser seco y la m quina f cilmente accesible Evitar la recirculaci n del aire el aire que sale ya caliente no debe mezclarse con el de ingreso para refrigeraci n 3 5 CONEXI N 3 5 1 Medir la tensi n generada de las tres fases corriente alterna en los bornes