1. 12 or 12A drive unit Refer to 77 2990 for information about the The Stationary Paddle Kit 28 comes standard only on 10 and 15 gallon tanks 28 The 5 and 10 gallon tanks come standard with one Agitator Paddle Kit 26 2 two Agitator Paddle Kits 26 Agitator Regulator Hook Up with Standard Regulation 1 or 2 Regulators 6 ae The 15 gallon E tanks come s standard with 26 4 ao 25 13 i1 pr fj P i Agitator Regulator Hook Up with Extra Sensitive Regulation 1 or 2 Regulators Requires 40 PSI Safety Valve 12 Ya NPT EF A PETROLEUM JELLY GREASE For bottom outlet conversion remove and discard plug e Grounding Diagram Purchase hardware locally p 5 16 18 Hex Head Nut 2 Required 5 16 18 x 3 4 Lon Hex Head Bolt 1 Required Sufficient Length 12 Gauge Wire Not Shown 5 16 Lock Washer 1 Required Tank Skirt Ref HIT 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES PARTS LIST ITEM NO 0 uU B5 os sy 07 25 39 Purchase locally KK 5014 Clamp Pin and Screw Kit includes 1 each of items 30 31 32 and 33 PART NO QMS 447 QMG 409 55G 8184 K2 KK 5042 QMG 19 TIA 5110 TIA 5040 QMG 21 55 2707 83 524 83 1207 VA 540 QMG 402 1 QM 1458 1 QMS 445 PTL 408 K20 PTL 412 K8 PTL 4
2. Bottom Outlet Optional Kit 304 Stainless Steel 3 4 14 NPS M TANK CAPACITIES Nominal Capacity Actual Capacity 5 US Gallons 9 8 US Gallons 10 US Gallons 15 US Gallons 11 8 US Gallons 19 8 US Gallons AIR CONTROL OPTIONS TYPE APPLICATION No Regulation Air inlet pressure gauge only Holding tanks Transfer tanks Used where precision fluid pressure control is not required Standard Single Regulation Provides standard fluid pressure control only For use where precision control of both fluid and air pressures is not required Also Used where atomization air can be taken from filter regulator air lines Standard Double Regulation Precision control for use with materials that are best applied at low closely controlled fluid and atomization air pressures Used with portable air compressors or with air lines when no other means of air pressure regulation is available Extra Sensitive Regulation Provides extremely accurate low pressure fluid pressure control Extra Sensitive Regulation with Standard Gun Regulation Provides extremely accurate low pressure fluid pressure control plus precision control of spray gun atomizing air AGITATION OPTIONS TYPE No Agitation APPLICATION Materials that require minimal or no mixing and or readily hold any solids in suspension Gear reduced Drive Agitation Heavy duty agitat
3. QMG 419 for 10 gallon tanks QMG 420 for 15 gallon tanks 15 GAL QTY 1 2 BINKS 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES AIR CONTROL SINGLE REGULATOR AIR CONTROL Control tank pressure only 85 470 for non agitated tanks 85 471 for agitated tanks tems with an asterisk are for use with an agitator ITEM PART NO NO DESCRIPTION 85 470 85 471 1 HAR 511 AIR REGULATOR 1 1 2 0 BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 VA 542 BALL VALVE 2 2 4 83 1290 GAUGE 150 PSI 1 1 5 SSP 8217 ZN SWIVEL ADAPTER 1 1 6 0000 1 4 NPT PLUG SUPPLIED W REGULATOR 1 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP 30 ZN SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 Purchase locally Refer to 77 2781 for regulator service parts DOUBLE REGULATOR AIR CONTROL Control tank pressure and spray gun atomization pressure 85 472 for non agitated tanks 85 473 for agitated tanks tems with an asterisk are for use with an agitator ITEM PART NO NO DESCRIPTION 85 472 85 473 1 511 AIR REGULATOR 1 1 2 e 0 BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 VA 542 BALL VALVE 2 2 4 83 1290 GAUGE 150 PSI 1 1 5 SSP 8217 ZN SWIVEL ADAPTER 1 1 6 senene 1 4 NPT PLUG SUPPLIED W REGULATOR 2 1 7 83 4233 D M NIPPLE 1 4 x 3 8 1 1 8 507 AIR REGULATOR 1 1 9 83 1355 GAUGE 100 PSI 1 1 1 2008 NIPPLE 1 4 NPS x 1 4 11 SSP 30 ZN SWIVEL ELBOW 1 4 NPS m x 1 4
4. 85 493 for agitated tanks tems with an asterisk are for use with an agitator AIR IN ITEM PART 2 DESCRIPTION 85 492 85 493 1 1 HAR 501 EXTRA SENSITIVE REGULATOR 1 1 2 Ak BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 SSP 2629 ZN MALE BRANCH TEE 1 4NPT 1 1 4 SSP 8217 ZN SWIVEL ADAPTER 1 1 5 83 1414 GAUGE 30 PSI 1 1 6 ek 1 4 NPT STREET TEE 1 2 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 9 VA 542 BALL VALVE 2 2 10 o 1 4 NPT PLUG SUPPLIED W REGULATOR 2 2 11 83 4233 D M NIPPLE 1 4 x 3 8 1 1 12 HAR 507 AIR REGULATOR 1 1 13 83 1355 GAUGE 100 PSI 1 1 14 TIA 5040 SAFETY VALVE 40 PSI NOT SHOWN 1 1 Purchase locally Refer to SB 6 131 for regulator service parts Refer to SBBI 6 147 for regulator service parts BITMKS 85 469 CONVERSION TO DOUBLE REGULATOR ASSEMBLY KIT Convert standard single regulator or extra sensitive air control to a double regulator air control ITEM PART NO NO DESCRIPTION QTY 6 1 4 NPT PLUG SUPPLIED W REGULATOR 1 amp 7 83 4233 D M NIPPLE 1 4 x 3 8 1 s 8 HAR 507 AIR REGULATOR 1 1 9 83 1355 GAUGE 100 PSI y Bo ePurchase locally IN EXISTING REGULATOR QMS 4003 NO REGULATION KIT Use when fluid pressure in tank is regulated by some other separate method of control ITEM PART NO NO DESCRIPTION QTY 1 ADAPTER 1 4 NPT
5. nica aire regulado s lo al tanque Engranaje reducido reforzado 183G 520 Doble aire regulado al tanque y la pistola Ninguna 183G 523 Doble aire regulado al tanque y la pistola Engranaje reducido reforzado 183G 530 Extra sensible Ninguna 183G 533 Extra sensible Engranaje reducido reforzado 183G 540 Extra sensible c regulaci n de pistola Ninguna 183G 543 Extra sensible c regulaci n de pistola Engranaje reducido reforzado MODELOS GALVANIZADOS DE 10 GALONES Modelo del tanque Regulaci n Agitaci n 183G 1000 Ninguna Ninguna 183G 1010 nica aire regulado s lo al tanque Ninguna 183G 1013 nica aire regulado s lo al tanque Engranaje reducido reforzado 183G 1020 Doble aire regulado al tanque y la pistola Ninguna 183G 1023 Doble aire regulado al tanque y la pistola Engranaje reducido reforzado 183G 1030 Extra sensible nica Ninguna 183G 1033 Extra sensible nica Engranaje reducido reforzado 183G 1040 Extra sensible c regulaci n de pistola Ninguna 183G 1043 Extra sensible c regulaci n de pistola Engranaje reducido reforzado MODELOS GALVANIZADOS DE 15 GALONES Modelo del tanque Regulaci n Agitaci n 183G 1500 Ninguna Ninguna 183G 1510 nica aire regulado s lo al tanque Ninguna 183G 1513 nica aire regulado s lo al tanque Engranaje reducido reforzado 183G 1520 Doble aire regulado al tanque y la pis
6. El obturador del eje del agitador no requiere de lubricaci n CONDICI N CAUSA CORRECCI N regulador Escape de aire del puerto en la tapa del Diafragma roto o da ado Reemplazar el diafragma man metro Corrimiento de presi n registrado en el Asiento de v lvula sucio o gastado en el regulador Limpiar o reemplazar el asiento de la v lvula El material tiende a desprenderse r pidamente Material sin agitaci n suficiente Aumentar la agitaci n Escape de aire en el obturador del agitador Conjunto del obturador defectuoso Reemplazar de cojinete del agitador Esparcimiento de la pintura al conjunto 1 Nivel de pintura muy alto en el tanque 2 Obturador del eje del agitador defectuoso 1 Mantener el nivel de fluido debajo del conjunto de cojinete 2 Reemplazar Escape de fluido o aire en el empaque de la tapa 1 Tornillo de mariposa no apretado 2 Empaque de la tapa defectuoso 1 2 Apretar Reemplazar Escape de fluido o aire en el empaque del puerto de llenado 1 Sombrerete del puerto de llenado no apretado 2 Empaque del puerto de llenado defectuoso N Apretar Reemplazar Aire mezclado con pintura 1 Tubo de fluidos no sellado a la tapa 2 Agitaci n excesiva Apretar el tubo de fluidos en la tapa Reducir la velocidad del agitador S 5 BITMKS CONJUNTOS DE TANQUES GA
7. Turn on atomization air to spray gun at source of supply 7 Test spray For further instructions consult literature provided with spray gun 8 If an air motor driven agitator is used start the agitator by slowly opening up the needle valve Air motor speed should be regulated according to the nature of the material being agitated MAINTENANCE To clean equipment proceed as follows 1 Turn off the air supply 2 Follow the pressure relief procedure 3 Turn T handle adjusting screw on tank fluid pressure regulator counterclockwise until no spring pressure is felt Turn handle on tank pressure regulator 4 Loosen thumb screws 17 tip clamps 16 back and tip lid 11 to one side of tank Do not remove lid from tank 5 Loosen spray gun air cap retaining ring about three turns 6 Turn on air supply 7 Cup cloth over air cap on the gun and pull trigger This will force material back through the hose into the tank 8 Empty and clean tank and parts that come into contact with material Use a solvent compatible with material being used 9 Pour solvent into tank 10 Replace lid and tighten thumb screws and clamps 11 Spray until clean solvent appears 12 Repeat steps 4 through 8 LUBRICATION Agitated Models Refer to the service manual provided with the air motor for lubrication information The bearings in the agitator bearing assembly are impregnated with special non gumming oil Ad
8. explosion or electric shock and other serious injury INSPECT THE EQUIPMENT DAILY Inspect the equipment for worn or broken parts on a daily basis Do not operate the equipment if you are uncertain about its condition PINCH POINT HAZARD Moving parts can crush and cut Pinch points are basically any areas where there are moving parts NEVER MODIFY THE EQUIPMENT Do not modify the equipment unless the manufacturer provides written approval NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment KNOW WHERE AND HOW TO SHUT OFF THE EQUIPMENT IN CASE OF AN EMERGENCY K e STATIC CHARGE PROP 65 WARNING Fluid may develop a static charge that must be dissipated through CA PROP WARNING This product contains chemicals known to the proper grounding of the equipment objects to be sprayed and all State of California to cause cancer and birth defects or other other electrically conductive objects in the dispensing area Improper reproductive harm grounding or sparks can cause a hazardous condition and result in fire explosion or electric shock and other serious injury WEAR SAFETY GLASSES Failure to wear safety glasses with side shields could result in serious eye injury or blindness IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT FOR FURTHER SAFETY INFORMATION REGARDING BINKS AND DEVILBISS EQUIPMENT SEE THE GENERAL
9. 1 1 9 83 1355 MAN METRO 100 PSI 1 1 10 2008 BOQUILLA 1 4 NPS x 1 4 NPT 1 ii s GIRATORIO 1 4 NPS m x 1 4 NPS 1 Se vende localmente Consulte 77 2781 para piezas de servicio del regulador Para piezas de servicio del regulador consulte SBBI 6 147 S 8 HIT CONJUNTOS DE TANQUES GALVANIZADOS DE 10 05 15 GALONES CONTROL EXTRA SENSIBLE DE AIRE CONTROL DE AIRE CON REGULADOR EXTRA SENSIBLE Y REGULADOR NICO A 6 gt g Proporciona control de precisi n sumamente alta s lo de la A A 229 presi n del tanque de 0 30 PSI Incluye v lvula de seguridad X Mo a 7 de 40 PSI ilustrada c d m EJ 85 490 para tanques sin agitaci n ENTRADA 85 491 para tanques con agitaci n DE AIRE Los art culos con asterisco son para uso con un agitador M 3 ART PIEZA DESCRIPCI N 85 490 p S 1 HAR 501 REGULADOR EXTRA SENSIBLE 1 i 2 MANGUITO ACERO ENCHAPADO 3 8 1 4 f 2 2 3 SSP 2629 ZN T ROSCADA CON DERIVACI N MACHO 1 4 1 1 AL TANQUE 4 SSP 8217 ZN ADAPTADOR GIRATORIO 1 1 5 83 1414 MAN METRO 30 PSI 1 1 6 T ROSCADA MACHO Y HEMBRA 1 4 NPT 1 2 7 H 2008 BOQUILLA 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 CODO GIRATORIO 1 4 NPS m x 1 4 NPS sw 1 9 VA 542 V LVULA ESF RICA 2 2 10 TIA 5040 SEGURIDAD 40 PSI NO 1 1 Se vende localmente Para piezas de servicio del regulador consulte SB 6 131 CON
10. 5732 BINKS DeVilbiss Automotive Refinishing Binks has authorized distributors throughout the world For equipment parts and service check the Yellow Pages under Automotive Body Shop Equipment and Supplies For technical assistance see listing below U S A Canada Customer Service Office 11360 S Airfield Road Swanton OH 43558 Toll Free Telephone 1 800 445 3988 U S A and Canada only Toll Free Fax 1 800 445 6643 9 13 2013 Binks All rights reserved Printed in U S A TANQUES ASME 183G GALVANIZADOS DE 5 10 y 15 GALONES DESCRIPCI N Los tanques alimentados a presi n de Binks est n destinados para ser utilizados como un recipiente a presi n para suministrar materiales a una presi n constante prefijada hasta un m ximo de 110 psi Los tanques son fabricados siguiendo las especificaciones de ASME Tambi n certificado para el funcionamiento en vac o Importante Lea y siga todas las instrucciones y PRECAUCIONES DE SEGURIDAD antes de usar este equipo Guardar para referencia en el futuro CAPACIDADES REALES El de 5 galones tiene capacidad para 9 8 galones o un balde de 5 galones El de 10 galones tiene capacidad para 11 8 galones El de 15 galones tiene capacidad para 19 8 galones MODELOS GALVANIZADOS DE 5 GALONES Modelo del tanque Regulaci n Agitaci n 183G 500 Ninguna Ninguna 183G 510 nica aire regulado s lo al tanque Ninguna 183G 513
11. AGITADOR 1 1 2 25 gt TORNILLO DE CABEZA ENCASTRADA 5 16 18 X 1 1 4 Al 1 2 3 26 QMS 444 KIT DE PALETAS DEL AGITADOR INCL 24 y 25 1 1 2 27 PALETA ESTACIONARIA 1 1 28 QMS 445 KIT DE PALETAS ESTACIONARIAS INCL 25 y 27 wee 1 1 29 PTL 408 K20 REVESTIMIENTO INTERIOR DESECHABLE DEL TANQUE 5 GAL 1 29 PTL 412 K8 REVESTIMIENTO INTERIOR DESECHABLE DEL TANQUE 10 29 PTL 415 K10 REVESTIMIENTO INTERIOR DESECHABLE DEL TANQUE 15 GAL 1 30 QM 1352 TORNILLO DE MARIPOSA VER ART 34 6 6 6 31 CHAVETA 1 8 DI X 1 ARGO VER ART 34 6 6 6 2 PASADOR DE HORQUILLA VER ART 34 6 6 6 330000 ABRAZADERA VER ART 34 6 6 6 34 KK 5014 KIT DE ABRAZADERA CLAVIJA Y TORNILLO 6 6 6 35 QMG 505 1 CONJ DE TANQUE Y OREJETA 5 GAL 1 35 QMG 510 1 CONJ DE TANQUE Y OREJETA 10 o 35 QMG 515 1 CONJ DE TANQUE Y OREJETA 15 GAL wee nee 1 36 TAP N INFERIOR 1 1 1 37 HA 57011 CONJ DE MANGUERA NEUM TICA INCL C ART 39 1 1 1 38 VER P G 8 y 9 CONTROL DE AIRE 1 1 1 39 QS 5012 1 MOTOR DE AIRE UNIDAD DE LA CAJA DE ENGRANAJES 1 1 1 Se vende localmente A Los productos que est n disponibles por separado o como un conjunto agitador completo KK 5014 Kit de abrazadera chaveta y tornillo incluye 1 de c u de los art 30 31 32 y 33 QMG 418 para tanques de 5 galones QMG 419 para tanques de 10 galones QMG 420 para tanques de 15 galones BITMKS CONJUNTOS DE TANQUES GALVANI
12. NPS sw Purchase locally Refer to 77 2781 for regulator service parts Refer to SBBI 6 147 for regulator service parts 4 Y SAIR IN g 2 Y eb 3 Y NAIR IN _ 710 TOTANK 4 w BINK 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES EXTRA SENSITIVE AIR CONTROL EXTRA SENSITIVE REGULATOR AIR CONTROL SINGLE REGULATOR Xe oe Provides extremely high precision control of tank pressure A A y only from 0 30 PSI Includes 40 PSI Safety Valve not shown Ao a 7 a4 85 490 for non agitated tanks 297 2 85 491 for agitated tanks AIR IN tems with an asterisk are for use with an agi gitator fa M ITEM PART NO NO DESCRIPTION 85 490 85 491 i 1 501 EXTRA SENSITIVE REGULATOR 1 1 2 BUSHING STL PLTD 3 8 m x 1 4 f 2 2 3 SSP 2629 ZN MALE BRANCH TEE 1 4NPT 1 1 TO TANK 4 SSP 8217 ZN SWIVEL ADAPTER 1 1 83 1414 GAUGE 30 PSI 1 1 6 AQ 1 4 NPT STREET TEE 1 2 7 H 2008 NIPPLE 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 SWIVEL ELBOW 1 4 NPS m x 1 4 NPS sw 1 9 VA 542 BALL VALVE 2 2 10 TIA 5040 SAFETY VALVE 40 PSI NOT SHOWN 1 1 e Purchase locally Refer to SB 6 131 for regulator service parts EXTRA SENSITIVE REGULATOR AIR CONTROL DOUBLE REGULATOR Provides extremely high precision control of tank pressure plus 9 standard regulation for a spray gun Includes 40 PSI Safety Valve Not shown 85 492 for non agitated tanks
13. Prospector strainers are an economical way to remove foreign material from paint stain lacquer and coatings HFRL 508 HFRL 509 CLEAN AIR CONTROL UNITS These units are designed to remove dirt pipe scale and most liquid aerosol Includes an automatic drain which expels liquids which accumulate in Inner Diameter Outer Diamete Height Depth 11 75 298 45mm 5 375 390 52mm 3 75 95 25mm the filter bowl Case Qty PTS 5Gal K20 200 200 micron approx 65 wire mesh PTS 5Gal K20 400 400 micron 29 3100 SCRUBS approx 37 wire mesh HAND CLEANER TOWELS E 5 5 20 600 600 _ approx 28 wire mesh Scrubs are a pre moistened hand cleaner i SCRUBS towel for painters No water is needed SCRUBS es 83 2924 FLUID Y STRAINER Attaches on fluid outlet of tank Includes 100 mesh filter screen Additional filter screens in other mesh sizes available 11 WARRANTY This product is covered by Binks 1 Year Limited Warranty Binks Sales and Service www binks com Binks Binks has authorized distributors throughout the world For technical assistance or the distributor nearest you see listing below U S A Canada Customer Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 800 992 4657 U S A and Canada only Toll Free Fax 1 888 246
14. and gun None 183G 1023 Double Regulated air to tank and gun Gear reduced Heavy duty 183G 1030 Extra Sensitive Single None 183G 1033 Extra Sensitive Single Gear reduced Heavy duty 183G 1040 Extra Sensitive w gun regulation None 183G 1043 Extra Sensitive w gun regulation Gear reduced Heavy duty GALVANIZED 15 GALLON MODELS Tank Model Regulation Agitation 183G 1500 None None 183G 1510 Single Regulated air to tank only None 183G 1513 Single Regulated air to tank only Gear reduced Heavy duty 183G 1520 Double Regulated air to tank and gun None 183G 1523 Double Regulated air to tank and gun Gear reduced Heavy duty 183G 1530 Extra Sensitive Single None 183G 1533 Extra Sensitive Single Gear reduced Heavy duty 183G 1540 Extra Sensitive w gun regulation None 183G 1543 Extra Sensitive w gun regulation Gear reduced Heavy duty Replaces Part Part Sheet Sheet 77 2928R 4 77 2928R 5 BITMKS In this part sheet the words WARNING CAUTION and NOTE are used to emphasize important safety information as follows A WARNING CAUTION Hazards or unsafe practices which could Hazards or unsafe practices which could Important installation operation or result in severe personal injury death or result in minor personal injury product maintenance information substantial property damage or property damage AWARNING Read the following warnings before using this equipment READ THE MANUAL GET IMMEDI
15. control sumamente preciso de presi n baja presi n de fluido Regulaci n extra sensible con regulaci n de pistola est ndar Proporciona un control sumamente exacto de presi n baja presi n de fluido adem s de control de precisi n del aire de atomizaci n de la pistola pulverizadora OPCIONES DE AGITACI N TIPO APLICACI N Sin agitaci n Materiales que requieran mezcla m nima o ninguna mezcla y o mantienen de inmediato cualquier s lido en suspenso Agitaci n con impulsi n de engranaje reducido Agitador resistente para materiales con viscosidad de mediana a alta que requieran de mezcla y o suspensi n de s lidos BINKS CONJUNTOS DE TANQUES GALVANIZOS DE 10 05 15 GALONES OPERACI N Y REVISIONES DE SERVICIO 44 ADVERTENCIA La alta presi n puede ocasionar lesiones graves La presi n se mantiene en un tanque a presi n despu s de haber apagado el sistema Siga el procedimiento de liberaci n de presi n en la p gina 3 antes de abrir la tapa o el puerto de llenado o realizar labores de mantenimiento en el tanque PREPARACI N Mezcle y prepare el material que va a usar siguiendo las instrucciones del fabricante Filtre el material a trav s de un tamiz de malla fina para eliminar grumos piel y materias for neas que puedan penetrar y obstruir los conductos de fluido y o el equipo de pulverizaci n Siga el proceso de liberaci n de presi n que antecede P
16. from sources of ignition Ignition sources include hot objects mechanical sparks and arcing non explosion proof electrical equipment Ground the pressure tank by connecting one end of 12 gauge minimum ground wire to the pressure tank and the other end to a true earth ground Local codes may have additional grounding requirements See illustration on page 6 for grounding and grounding hardware required Never drill into weld or modify the tank in any way Do not adjust remove or tamper with the safety valve If replacement is necessary use the same type and rating of valve Read the label or data sheet for the material Do not use materials containing these solvents with galvanized pressure tanks Stainless steel tank models may be used with halogenated solvents Refer to specifications chart to ensure that fluids are chemically compatible with the tank wetted parts Before placing fluids or solvents in tank always read accompanying manufacturer s literature Operators should be given adequate training in the safe use and maintenance of the equipment in accordance with the requirements of NFPA 33 Chapter 15 in U S Users must comply with all local and national codes governing ventilation fire precautions operation maintenance and housekeeping in the U S these are OSHA sections 1910 94 and 1910 107 and NFPA 33 44 WARNING High pressure can cause serious injury PRESSURE RELIEF PROCEDURE T
17. imprevista lo que a su vez puede producir lesiones graves DESACTIVE DESPRESURICE DESCONECTE Y BLOQUEE TODAS LAS FUENTES DE ENERG A DURANTE EL MANTENIMIENTO No desactivar desconectar ni bloquear todas las fuentes de suministro de energ a antes de realizar operaciones de mantenimiento en los equipos puede ocasionar lesiones graves o la muerte CONSIDERACIONES DE ALTA PRESI N La alta presi n puede ocasionar lesiones graves Antes de reparar o dar mantenimiento a los equipos libere toda la presi n El atomizado de la pistola pulverizadora las filtraciones de la manguera o componentes averiados pueden inyectar fluido en su organismo y ocasionar lesiones sumamente graves PROCEDIMIENTO DE LIBERACI N DE PRESI N Siga siempre el procedimiento de liberaci n de presi n que aparece en el manual de instrucciones del equipo MANTENGA LAS DEFENSAS DEL EQUIPO EN SU LUGAR No operar los equipos si los dispositivos de seguridad fueron retirados EQUIPOS AUTOM TICOS Los equipos autom ticos pueden activarse s bitamente sin advertencia INSPECCIONE LOS EQUIPOS DIARIAMENTE Inspeccione diariamente los equipos para verificar que no tengan piezas gastadas o rotas No opere los equipos si no est seguro de esta condici n NUNCA MODIFIQUE LOS EQUIPOS No modifique el equipo sin la autorizaci n escrita del fabricante SEPA C MO Y D NDE DESACTIVAR LOS EQUIPOS EN CASO DE EMERGENCIA CARGA EST TICA Los fluidos pueden generar una ca
18. 15 K10 QM 1352 KK 5014 QMG 505 1 QMG 510 1 QMG 515 1 HA 57011 SEE PAGES 8 amp 9 QS 5012 1 DESCRIPTION RETAINING NUT THRUST WASHER THRUST COLLAR SET SCREW 5 16 18 X 3 8 THRUST COLLAR KIT INCL 4 amp 5 BEARING ASSY PLAIN STEEL O RING KIT OF 2 SHAFT SEAL 5 8 1 D INTERNAL RETAINING RING SHAFT SEAL KIT INCL 8 amp 9 PLUG NON AGITATED MODELS ONLY SAFETY VALVE ASSY 110 PSI SAFETY VALVE ASSY 40 PSI EXTRA SENSITIVE ONLY AIR MANIFOLD AIR RELIEF VALVE 1 4 NPT M FILL PORT CAP FILL PORT CAP GASKET STREET ELBOW 3 8 18 NPT Brass BALL VALVE 3 8 NPS OUTLET TANK LID TANK GASKET PLUG 1 2 14 NPT PLATED STEEL FLUID TUBE FLUID TUBE FLUID TUBE AGITATOR SHAFT AGITATOR SHAFT AGITATOR SHAFT AGITATOR PADDLE SOC HEAD CAP SCREW 5 16 18 X 1 1 4 S S AGITATOR PADDLE KIT INCL 24 amp 25 STATIONARY PADDLE STATIONARY PADDLE KIT INCL 25 amp 27 DISPOSABLE TANK LINER 5 GAL DISPOSABLE TANK LINER 10 GAL DISPOSABLE TANK LINER 15 GAL THUMB SCREW SEE ITEM 34 COTTER PIN 1 8 DIA X 1 LG SEE ITEM 34 CLEVIS PIN SEE ITEM 34 CLAMP SEE ITEM 34 CLAMP PIN amp SCREW KIT TANK amp LUG ASSY 5 GAL TANK amp LUG ASSY 10 GAL TANK amp LUG ASSY 15 GAL BOTTOM PLUG AIR HOSE ASS Y INCL W ITEM 39 AIR CONTROL AIR MOTOR GEARBOX DRIVE 5 GAL QTY 1 2 1 10 GAL QTY 1 2 A Items available separately or as a complete agitator assembly QMG 418 for 5 gallon tanks
19. 183G GALVANIZED 5 10 and 15 GALLON ASME TANKS Important Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment Retain for future reference DESCRIPTION Binks pressure feed tanks are intended for use as a pressure container to supply material at a constant preset pressure up to a maximum of 110 psi The tanks are built to ASME specifications Also certified for vacuum operation ACTUAL CAPACITIES 5 Gallon holds 9 8 gallons or a 5 gallon pail 10 Gallon holds 11 8 gallons 15 Gallon holds 19 8 gallons GALVANIZED 5 GALLON MODELS Tank Model Regulation Agitation 183G 500 None None 183G 510 Single Regulated air to tank only None 183G 513 Single Regulated air to tank only Gear reduced Heavy duty 183G 520 Double Regulated air to tank and gun None 183G 523 Double Regulated air to tank and gun Gear reduced Heavy duty 183G 530 Extra Sensitive None 183G 533 Extra Sensitive Gear reduced Heavy duty 183G 540 Extra Sensitive w gun regulation None 183G 543 Extra Sensitive w gun regulation Gear reduced Heavy duty GALVANIZED 10 GALLON MODELS Tank Model Regulation Agitation 183G 1000 None None 183G 1010 Single Regulated air to tank only None 183G 1013 Single Regulated air to tank only Gear reduced Heavy duty 183G 1020 Double Regulated air to tank
20. ATE MEDICAL ATTENTION Before operating finishing equipment read and understand all To prevent contact with the fluid please note the following safety operation and maintenance information provided in the a Never point the gun valve at anyone or any part of the body operation manual b Never put hand or fingers over the spray tip c Never attempt to stop or deflect fluid leaks with your hand body glove or rag OPERATOR TRAINING d Always have the tip guard on the spray gun before spraying All personnel must be trained before operating finishing e Always ensure that the gun trigger safety operates before equipment spraying f Always lock the gun trigger safety when you stop spraying MEDICAL ALERT Any injury caused by high pressure liquid can be serious If you are injured or even suspect an injury a Go to an emergency room immediately b Tell the doctor you suspect an injection injury c Show the doctor this medical information or the medical alert card provided with your airless spray equipment d Tell the doctor what kind of fluid you were spraying or EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture malfunction or start unexpectedly and result in serious injury DE ENERGIZE DEPRESSURIZE DISCONNECT AND LOCK OUT ALL POWER SOURCES DURING MAINTENANCE dispensing Failure to De energize disconnect and lock out all power e Refer to the Material Safety Data Sheet for specific supplies befo
21. EQUIPMENT SAFETY BOOKLET 77 5300 HIT 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES SAFEGUARDS The following hazards may occur during the normal use of this equipment Please read the following chart Fire Pressure tank Ag 4 Explosion Hazard Pressure Tank Static Electricity M Explosion Hazard Pressure Tank Rupture M Explosion Hazard Galvanized Tanks Material Compatibility M General Safety Solvents and coatings can be highly flammable or combustible especially when sprayed Vapors from flammable liquids can catch fire or explode Static electricity is created by the flow of fluid through the pressure tank and hose If all parts are not properly grounded sparking may occur Sparks can ignite vapors from solvents and the fluid being sprayed Making changes to a pressure tank will weaken it Halogenated hydrocarbon solvents for example 1 1 1 Trichloroethane and methylene chloride can chemically react with aluminum parts and components and cause an explosion hazard These solvents will also corrode the galvanized tank coating Improper operation or maintenance may create a hazard CAUSE SAFEGUARDS 1 Adequate exhaust must be provided to keep the air free of accumulations of flammable vapors 2 Smoking must never be allowed in the spray area 3 Fire extinguishing equipment must be present in the spray area Keep tank at least 10 feet away
22. ESI N PROSPECTOR PARA TANQUES DE 5 10 Y 15 GALONES Los filtros de malla ProspectorTM son una forma econ mica de eliminar las materias for neas de la pintura manchas barnices y revestimientos Di metro interior 11 75 298 45 mm Di metro exterior 15 375 390 52 mm Alt Profundidad 3 75 95 25 mm Cantidad caja rencia 20 PTS 5Gal K20 200 200 micrones aprox malla de alambre 65 PTS 5Gal K20 400 400 micrones aprox malla de alambre 37 PTS 5Gal K20 600 600 micrones aprox malla de alambre 28 Este producto est cubierto por la Garant a Limitada por 1 A o de Binks Centros de venta y servicios de Binks www binks com Binks DeVilbiss Automotive Refinishing Binks tiene distribuidores autorizados en todo el mundo Para asistencia t cnica Binks tiene distribuidores autorizados en todo el mundo Para equipos o localizar al distribuidor m s cercano consulte la lista a continuaci n repuestos y servicio de mantenimiento consulte las P ginas Amarillas bajo Equipos y suministros para talleres de repintado automotriz Para Oficina de servicios t cnicos en EE UU Canad Rud s asistencia t cnica consulte la lista abajo 195 Internationale Blvd Glendale Heights IL 60139 9 L nea gratuita 1 800 992 4657 EE UU y Canad nicamente Oficina de servicio al cliente en EE UU Can
23. F X 1 4 NPS SW 1 amp 2 e STREET TEE 1 4 3 83 1290 GAUGE 150 PSI 1 w A 4 VA 542 BALL VALVE 1 T ePurchase locally Mo AIR IN Y BOTTOM OUTLET KIT BOTTOM OUTLET KIT WITH LEGS Allows conversion of tank from standard top outlet to bottom outlet All bottom outlet wetted parts are stainless steel 183 3001 for 5 10 and 15 gallon tanks with 34 bottom outlets Includes three 183 3005 Leg Kits b TA MP oy Cyl Inward orientation ITEM PART Outward orientation NO NO DESCRIPTION QTY 1 ADAPTER 3 4 NPT NPS UNIVERSAL 2 2 ELBOW 3 4 NPT F 1 3 PIPE NIPPLE 1 Legs can be oriented either inward or outward to provide 7 BALL VALVE 3 4 FULL PORT 1 flexibility in mounting 5 183 3005 LEG KIT 3 10 BINK ACCESSORIES VS 534 FLUID STRAINER Primary fluid strainer that attaches between fluid outlet valve and fluid hose to strain material Components made of stainless steel with a nylon filter Comes standard with 100 mesh screen For more information see SB 7 072 DISPOSABLE TANK LINERS Molded polyethylene tank liners reduce solvent waste and tank cleanup time The liner is made of tough durable leakproof poly ethylene and can be used with all compatible materials PTL 408 K20 Kit of 20 tank liners 9 8 gal PTL 412 K8 Kit of 8 tank liners 11 8 gal PTL 415 K10 Kit of 10 liners 19 8 gal PROSPECTOR PRESSURE TANK STRAINERS FOR 5 10 AND 15 GALLON TANKS
24. I 12A ori S 6 HIT CONJUNTOS DE TANQUES GALVANIZADOS DE 10 05 15 GALONES LISTA DE PIEZAS ART 5GAL 10GAL 15GAL NO PIEZA NO DESCRIPCI N CANT CANT CANT 1 A QMS 46 TUERCA DE RETENCI N 1 1 2 A QMG 85 ARANDELA DE EMPUJE 2 2 2 3 A gt COLLAR DE EMPUJE 1 1 4 he TORNILLO PRISIONERO 5 16 18 X 3 8 1 1 5 QMS 447 KIT DE COLLARES DE EMPUJE INCL 4 y 5 1 1 6 A 409 DE COJINETE ACERO PURO 1 1 7 A SSG 8184 K2 JUNTA T RICA KIT de 2 1 1 8 OBTURADOR DEL EJE D I 5 8 1 1 9 A gt ANILLO DE RETENCION INTERNO 1 1 10 KK 5042 KIT DE OBTURADORES DEL EJE INCL 8 y 9 1 1 11 QMG 19 TAP N S LO MODELOS SIN AGITACI N 1 1 12 TIA 5110 DE V LVULA DE SEGURIDAD 110 PSI 1 1 128 TIA 5040 Miro rm DE SEGURIDAD 40 PSI SOLO EXTRA 13 QMG 21 COLECTOR DE AIRE 1 1 14 55 2707 V LVULA DE LIBERACI N DE AIRE 1 4 NPT M 1 1 15 83 524 SOMBRERETE DEL PUERTO DE LLENADO 1 1 16 83 1207 EMPAQUE DEL SOMBRERETE DEL PUERTO DE LLENADO 1 1 17 CODO MACHO Y HEMBRA 3 8 18 NPT lat n 1 1 18 VA 540 V LVULA ESF RICA SALIDA 3 8 NPS 1 1 19 QMG 402 1 TAPA DEL TANQUE 1 1 20 QM 1458 1 EMPAQUE DEL TANQUE 1 1 21 Sr TAP N 1 2 14 NPT ACERO ENCHAPADO 1 1 22 QMG 32 TUBO DE FLUIDOS 1 22 QMG 33 TUBO DE FLUIDOS nee 1 22 QMG 34 TUBO DE FLUIDOS ene e 1 23 A QMG 28 EJE DEL AGITADOR 1 23 A QMG 29 EJE DEL AGITADOR nen 1 23 A QMG 30 EJEDELAGITADOR nee nen 1 24 o PALETA DEL
25. LVANIZADOS DE 10 05 15 GALONES Para informaci n acerca de NOTA la unidad de impulsi n consulte 77 2990 Use sellador de rosca con base de NOTA PTFE en todas las conexiones de El lado abierto del obturador aire y fluido 39 del eje 8 est orientado 37 hacia abajo El retenedor 9 se necesita 1 PRECAUCI N s lo para operaci n al vac o Use una v lvula de seguridad de 40 2 4 PSI 12 4 sensible E 6 2 a 4 _ 12 or 12A a _ 13 LN aot d pen 1 NPS 20 El kit de paletas estacionarias 28 viene est ndar s lo en los tanques de 10 y 15 galones 28 Los tanques de 5 777 35 y 10 galones vienen est ndares con un kit de paleta xe agitador 26 VASELINA GRASA Para conversi n de salida inferior quite y deseche el tap n 25 Los tanques de 15 galones venena est ndares con dos kits de o 25 y f del agitador 26 zd NPT Diagrama de conexi n a tierra Compre los accesorios Tuerca de cabeza localmente hexagonal 5 16 18 se necesitan 2 Perno de cabeza hexagonal 5 16 18 x 3 4 largo se necesita 1 Enganche del agitador regulador Enganche del agitador regulador Longitud suficiente con regulaci n est ndar con regulaci n extra sensible ie 1 6 2 reguladores 1 6 2 reguladores Requiere v lvula de Arandela de seguridad 5 16 se necesita 1 seguridad de 40 PS
26. N CANT 6 e TAP N 1 4 NPT PROVISTO C 1 amp REGULADOR SES 7 83 4233 BOQUILLA DM 1 4 x 3 8 1 KC je 8 HAR 507 REGULADOR DE AIRE 1 3 9 83 1355 MANOMETRO 100 PSI 1 A eSe vende localmente DE AIRE REGULADOR EXISTENTE QMS 4003 KIT SIN REGULACI N Usar cuando la presi n de fluido en el tanque es regulada por alg n otro m todo de control separado ART PIEZA NO NO DESCRIPCI N CANT 1 _ ADAPTADOR 1 4 NPT F X 1 4 NPS 1 SW 2 TROSCADA MACHO Y HEMBRA 1 y 3 83 1290 MAN METRO 150 PSI 1 4 VA 542 V LVULA ESF RICA 1 Ky Se vende localmente gt ENTRADA um 1 DE AIRE KIT DE SALIDA INFERIOR Y KIT DE SALIDA INFERIOR CON PATAS o 3 i Permite la conversion del tanque de salida superior estandar 3 lt a salida inferior Todas las piezas mojadas de la salida inferior i E son de acero inoxidable 5 P 183 3001 para tanques de 5 10 y 15 gal c salida inferior de 34 Incluye tres kits de patas 183 3005 Orientaci n hacia el interior ART PIEZA gt NO NO DESCRIPCI N CANT Orientaci n hacia el SS oN exterior 1 ADAPTADOR 3 4 NPT NPS 3 UNIVERSAL 2 CODO 3 4 NPT F 1 3 BOQUILLA DE TUBO 1 Las patas se pueden orientar hacia adentro o hacia afuera para 4 m V LVULA ESF RICA 3 4 NPT 1 proporcionar flexibilidad en el montaje PUERTO COMPLETO 5 183 3005 KIT DE PATAS 3 S 10 HIT VS 534 FILTRO DE FLUIDO Filtro de fluido prima
27. TROL DE AIRE CON REGULADOR EXTRA SENSIBLE Y REGULADOR DOBLE Proporciona control de precisi n sumamente alta de la presi n del tanque adem s de regulaci n est ndar para una pistola pulverizadora Incluye v lvula de seguridad de 40 PSI no ilustrada 85 492 para tanques sin agitaci n 85 493 para tanques con agitaci n Los art culos con asterisco son para uso con un agitador ART NO PIEZA NO DESCRIPCI N 1 HAR 501 REGULADOR EXTRA SENSIBLE 2 9 7 0 MANGUITO ACERO ENCHAPADO 3 8 m x 1 4 i 4 3 SSP 2629 ZN T ROSCADA CON DERIVACI N MACHO 1 4 NPT 1 1 4 SSP 8217 ZN ADAPTADOR GIRATORIO 1 1 5 83 1414 MAN METRO 30 PSI 1 1 AL TANQUE 6 e 0 T ROSCADA MACHO Y HEMBRA 1 4 NPT 1 2 7 2008 BOQUILLA 1 4 NPS x 1 4 NPT 1 8 SSP ZN 30 CODO GIRATORIO 1 4 NPS m x 1 4 NPS sw 1 9 VA 542 V LVULA ESF RICA 2 2 10 TAP N 1 4 NPT PROVISTO C REGULADOR 2 2 11 83 4233 BOQUILLA DE ENTRADA DM 1 4 x 3 8 1 1 12 507 REGULADOR DE AIRE 1 1 13 83 1355 MAN METRO 100 PSI 1 1 14 TIA 5040 SEGURIDAD 40 PSI NO 1 1 Se vende localmente Para piezas de servicio del regulador consulte SB 6 131 Para piezas de servicio del regulador consulte SBBI 6 147 S 9 BITMKS 85 469 KIT DE CONVERSI N AL CONJUNTO DE REGULADOR DOBLE Convierte el regulador nico est ndar o control de aire extra sensible a control de aire con regulador doble ART PIEZA DESCRIPCI
28. ZADOS DE 10 05 15 GALONES CONTROL DE AIRE 4 CONTROL DE AIRE CON REGULADOR NICO S lo controla la presi n del tanque 85 470 para tanques sin agitaci n 85 471 para tanques con agitaci n Los art culos con asterisco son para uso con un agitador NO PIEZA NO DESCRIPCI N 85 470 85 1 HAR 511 REGULADOR DE AIRE 1 2 MANGUITO ACERO ENCHAPADO 3 8 1 4 f 2 3 VA 542 V LVULA ESF RICA 2 4 83 1290 MAN METRO 150 PSI 1 5 SSP 8217 ZN ADAPTADOR GIRATORIO 1 1 6 e 000 TAP N 1 4 NPT PROVISTO C REGULADOR 1 7 H 2008 BOQUILLA 1 4 NPS x 1 4 NPT 1 8 SSP 30 ZN CODO GIRATORIO 1 4 NPS m x 1 4 NPS sw 1 Se vende localmente Para piezas de servicio del regulador consulte 77 2781 CONTROL DE AIRE CON REGULADOR DOBLE Presi n del tanque de control y presi n de atomizaci n de la pistola pulverizadora 85 472 para tanques sin agitaci n 85 473 para tanques con agitaci n Los art culos con asterisco son para uso con un agitador a Ds ENTRADA h DE AIRE ART NO PIEZA NO DESCRIPCI N 8 5 T 1 511 REGULADOR DE AIRE T TN MANGUITO ACERO ENCHAPADO 3 8 m ALTANQUE 4 w x 1 4 f 3 VA 542 V LVULA ESF RICA 2 2 4 83 1290 150 PSI 1 1 5 SSP 8217 ZN ADAPTADOR GIRATORIO 1 1 6 0 TAP N 1 4 NPT PROVISTO C REGULADOR 2 1 7 83 4233 BOQUILLA DE ENTRADA DM 1 4 x 3 8 1 1 8 4 507 REGULADOR DE AIRE
29. ada Fax gratuito 1 888 246 5732 11360 S Airfield Road Swanton OH 43558 Tel fono gratuito 1 800 445 3988 EE UU y Canad nicamente Fax gratuito 1 800 445 6643 BITIKS 9 13 2013 Binks Reservados todos los derechos Impreso en EE UU
30. altamente inflamables o combustibles especialmente cuando se atomizan Los vapores provenientes de l quidos inflamables pueden prender fuego o explotar La electricidad est tica se crea por el flujo de fluido a trav s del tanque a presi n y la manguera Si todas las piezas no tienen la debida conexi n a tierra podr an producirse chispas Las chispas pueden encender los vapores de los solventes y el fluido que est siendo atomizado Hacer cambios a un tanque a presi n lo debilitar Los solventes con hidrocarburos halogenados por ejemplo 1 1 1 tricloroetano y cloruro de metileno pueden reaccionar qu micamente con las piezas y componentes de aluminio y ocasionar peligro de explosi n Estos solventes tambi n corroen el recubrimiento del tanque galvanizado La operaci n o mantenimiento indebidos pueden crear un peligro 1 Debe proveerse de un escape adecuado para mantener el aire libre de acumulaciones de vapores inflamables 2 Nunca debe permitirse fumar en el rea donde se atomiza 3 En el rea donde se atomiza debe haber equipo extintor de incendios Mantenga el tanque al menos a 10 pies de distancia de las fuentes de ignici n Las fuentes de ignici n incluyen objetos calientes chispas mec nicas y equipos el ctricos con formaci n de arcos no a prueba de explosiones Haga la conexi n a tierra del tanque a presi n acoplando un extremo del cable de tierra calibre 12 m nimo al tanqu
31. ara agregar material al tanque quite la tapa y vierta el material directamente en el tanque o contenedor Si lo desea se puede colocar directamente sobre el tanque un balde de 1 gal n de fluido en sistema estadounidense o m trico Vuelva a colocar el conjunto de la tapa y apriete los tornillos de mariposa 17 con firmeza El suministro de aire al tanque debe incluir un separador de agua filtro para filtrar la suciedad del aire y eliminar el agua y el aceite Conecte la manguera del material a la v lvula esf rica de salida de fluido 8 OPERACI N 1 Cierre la v lvula de entrada de aire al tanque Haga girar el mango del regulador en sentido antihorario hasta que se libere la tensi n del resorte 2 Abra el suministro de aire al tanque 3 Abra la v lvula de entrada de aire al tanque 4 Abra la v lvula de salida de fluido 5 Haga girar el mango del regulador de la presi n del tanque en sentido horario para presurizar el tanque 6 Active el aire de atomizaci n hacia la pistola pulverizadora en la fuente del suministro 7 Pruebe el pulverizador Para m s instrucciones consulte los materiales impresos provistos con la pistola pulverizadora 8 Si se utiliza un agitador accionado por motor de aire ponga en marcha el agitador abriendo lentamente la v lvula de aguja La velocidad del motor de aire se debe regular seg n la naturaleza del material que se est agitando MANTENIMIENTO Para limp
32. bra de vidrio Eje del agitador Acero enchapado en zinc Obturador del eje del agitador PTFE tecnificado acero inoxidable Colector de aire Acero enchapado en zinc Tap n acoplamiento del colector de aire Acero enchapado en zinc Salida inferior kit opcional Acero inoxidable 304 3 4 14 NPS M CAPACIDADES DEL TANQUE Capacidad nominal 5 galones EEUU 10 galones EEUU 15 galones EEUU Capacidad actual 9 8 galones EEUU 11 8 galones EEUU 19 8 galones EEUU OPCIONES PARA CONTROL DE AIRE TIPO Sin regulaci n s lo man metro de entrada de aire APLICACI N Tanques de retenci n tanques de transferencia usado d nde no se requiera de control de precisi n de la presi n de fluido Regulaci n nica est ndar Proporciona control de presi n de fluido est ndar solamente Para uso donde no se requiera control de precisi n tanto de fluido como de la presi n de aire Tambi n usado donde el aire de atomizaci n se pueda tomar de las l neas de aire del filtro regulador Regulaci n doble est ndar Control de precisi n para uso con materiales que se aplican mejor a presiones de fluido y aire de atomizaci n bajas estrechamente controladas Usado con compresores de aire port tiles o con l neas de aire cuando no est disponible ning n otro medio de regulaci n de la presi n de aire Regulaci n extra sensible Proporciona un
33. ditional lubrication is not required The agitator shaft seal does not require lubrication SERVICE CHECKS CONDITION CAUSE CORRECTION Air escaping from port on regulator cap Broken or damaged diaphragm Replace diaphragm Pressure creepage registered on gauge Material tends to settle out rapidly Dirty or worn valve seat in regulator Not enough agitation of material Clean or replace valve seat Increase agitation Air leakage at agitator seal Defective seal assembly Replace Paint getting into bearing assembly of agitator 1 Paint level in tank too high 2 Defective agitator shaft seal Keep fluid level under bearing ass y Replace Fluid or air leak at lid gasket Fluid or air leak at fill port gasket 1 Thumb screw not tight 2 Defective lid gasket 1 Fill port cap not tight 2 Defective fill port gasket Tighten Replace 1 Tighten 2 Replace Air mixing with paint 1 Fluid tube not sealed to lid 2 Excessive agitation 1 Tighten fluid tube into lid 2 Reduce speed of agitator BITMKS 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES NOTE Use PTFE based thread sealant on all air and fluid connections Open side of shaft seal 8 faces downward Retainer 9 required only for vacuum operation CAUTION Use 40 PSI Safety Valve 12A with an extra sensitive regulator
34. e a presi n y el otro extremo a una conexi n a tierra efectiva Los c digos locales pueden tener requisitos de conexi n a tierra adicionales Ver en la ilustraci n de la p gina 6 los requisitos de conexi n a tierra y los accesorios de conexi n a tierra requeridos Nunca perfore solde o modifique de ninguna manera el tanque No ajuste quite o manipule indebidamente la v lvula de seguridad Si fuese necesario reemplazar use una v lvula del mismo tipo y con la misma clasificaci n Lea la etiqueta y la hoja de informaci n del material No use materiales que contengan estos solventes con tanques a presi n galvanizados Se pueden usar modelos de tanques de acero inoxidable con solventes halogenados Consulte la tabla de especificaciones para asegurarse de que los fluidos sean qu micamente compatibles con las partes mojadas del tanque Antes de introducir fluidos o solventes en el tanque lea siempre los materiales impresos del fabricante adjuntos Los operadores deben recibir la capacitaci n adecuada en el uso y mantenimientos sin riesgos de acuerdo con los requisitos de NFPA 33 Cap tulo 15 en EEUU del equipo Los usuarios deben cumplir con todos los c digos locales y nacionales que rigen la ventilaci n las precauciones contra incendios la operaci n el mantenimiento y la limpieza en EEUU estas son las secciones 1910 94 y 1910 107 de OSHA y NFPA 33 PROCEDIMIENTO DE LIBERACI N DE PRESI N Para red
35. haya partes m viles PELIGRO DE RUIDO Usted puede resultar lesionado por el ruido muy fuerte Podr a necesitar protecci n de los o dos al usar este equipo ADVERTENCIA PROP 65 ADVERTENCIA Este producto contiene sustancias qu micas que seg n informaci n en poder del estado de California producen c ncer defectos de nacimiento y otros da os al sistema reproductor ES RESPONSABILIDAD DEL EMPLEADOR SUMINISTRAR ESTA INFORMACI N AL OPERADOR DEL EQUIPO PARA M S INFORMACI N DE SEGURIDAD ACERCA DE LOS EQUIPOS BINKS Y DEVILBISS CONSULTE EL FOLLETO DE gt SEGURIDAD GENERAL DE LOS EQUIPOS 77 5300 BInKs CONJUNTOS DE TANQUES GALVANIZADOS DE 10 05 15 GALONES MEDIDAS PREVENTIVAS Durante el uso normal de este equipo pueden ocurrir las siguientes situaciones de peligro S rvase leer la siguiente tabla PELIGRO CAUSA MEDIDAS PREVENTIVAS Incendio Incendio Tanque a presi n A 4 Peligro de explosi n Tanque a presi n Electricidad est tica M Peligro de explosi n Tanque a presi n Ruptura M Peligro de explosi n Tanques galvanizados Compatibilidad del material M Seguridad en general ADVERTENCIA La alta presi n puede ocasionar lesiones graves La presi n se mantiene en un tanque a presi n despu s de haber apagado el sistema Siga siempre este procedimiento para liberar la presi n del tanque Los solventes y recubrimientos pueden ser
36. iar el equipo proceda de la siguiente manera 1 Interrumpa el suministro de aire 2 Siga el procedimiento de liberaci n de presi n 3 Haga girar el tornillo de ajuste del mango en T en el regulador de presi n de fluido del tanque en sentido antihorario hasta que no se sienta presi n del resorte REVISIONES DE SERVICIO 4 Afloje los tornillos de mariposa 17 la parte posterior de la abrazadera de la punta 16 y la tapa de la punta 11 a un lado del tanque No quite la tapa del tanque 5 Afloje el anillo de retenci n de la tapa de aire de la pistola pulverizadora dando unas tres vueltas 6 Active el suministro de aire 7 Coloque un pa o sobre la tapa de aire en la pistola y accione el disparador Esto har que el material retorne a trav s de la manguera hacia el tanque 8 Vac e y limpie el tanque y las piezas que tienen contacto con el material Use un solvente compatible con el material que se est usando 9 Vierta el solvente en el tanque 10 Vuelva a colocar la tapa y apriete los tornillos de mariposa y las abrazaderas 11 Atomice hasta que aparezca el solvente limpio 12 Repita los pasos del 4 al 8 LUBRICACI N Modelos con agitaci n Consulte la informaci n sobre lubricaci n en el manual de servicio provisto con el motor de aire Los cojinetes en el conjunto de cojinetes del agitador est n impregnados con aceite especial no gomoso No se necesita lubricaci n adicional
37. la tarjeta de alerta m dica provista con su equipo de pulverizaci n sin aire d Informe al m dico acerca del tipo de fluido que estaba pulverizando o aplicando Consulte la informaci n espec fica en la Hoja de datos de seguridad USE UN RESPIRADOR La inhalaci n de vapores t xicos puede ocasionar lesiones graves o la muerte Use un respirador como lo recomienda la Hoja de datos de seguridad del fabricante de fluido y el solvente FLUIDOS Y VAPORES T XICOS Los fluidos peligrosos o los vapores t xicos pueden ocasionar lesiones graves o la muerte si se salpican a los ojos o la piel se inhalan se inyectan o ingieren APRENDA y CONOZCA los peligros espec ficos de los fluidos que est utilizando PELIGRO DE INCENDIO Y EXPLOSI N La conexi n a tierra indebida de los equipos la ventilaci n insuficiente la llama abierta o las chispas pueden ocasionar condiciones de peligro y producir incendios explosiones y otras lesiones graves PELIGRO DE PROYECTILES Usted puede resultar lesionado por dar salida a l quidos o gases liberados bajo presi n o por restos volanderos DESCARGA EL CTRICA CONEXI N A TIERRA La conexi n a tierra indebida o las chispas pueden ocasionar condiciones de peligro y producir incendios explosiones o descargas el ctricas y otras lesiones graves PELIGRO DE PUNTOS DE PRESI N Las partes m viles pueden aplastar y ocasionar cortaduras Los puntos de presi n son b sicamente todas las reas donde
38. o reduce the risk of injury follow the pressure relief procedure below Whenever the tank is left unattended Before checking or servicing any part of the spray system Before attempting removal of fill port cap or tank cover Pressure is maintained in a pressure tank after the system has been shut down 2 Close the air inlet valve located on the tank air manifold 1 Turn off the main air supply to the tank 3 Bleed off air in the tank by turning the air relief valve 5 thumb screw counterclockwise Wait until all Always follow this the air has escaped through the valve before removing the pressure tank cover or fill port cap procedure to relieve pressure tank 4 Leave the air relief valve open until you have reinstalled the tank cover or fill port cap BITMKS 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES SPECIFICATIONS 8 OPTIONS SPECIFICATIONS GALVANIZED TANKS Maximum Working Pressure 110 psi Tank Shell SA 414 Steel Galvanized Zinc Tank Lid SA 414 Steel Galvanized Zinc Fluid Tube 3 8 in Steel Pipe Galvanized Fluid Outlet Elbow Steel Zinc Plate Fluid Valve Outlet Brass Nickel Plate 3 8 18 NPS M Agitator Paddle Propeller Nylon Glass Filled Agitator Shaft Steel Zinc Plate Agitator Shaft Seal Engineered PTFE Stainless Steel Air Manifold Steel Zinc Plate Plug Air Manifold Coupling Steel Zinc Plate
39. or for medium to high viscosity materials that require mixing and or solids suspension BINKS 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES OPERATION amp SERVICE CHECKS A WARNING High pressure can cause serious injury Pressure is maintained in a pressure tank after the system has been shut down Follow the pressure relief procedure on page 3 before opening the lid or fill port or performing maintenance on the tank PREPARATION Mix and prepare material to be used according to manufacturer s instructions Strain material through a fine mesh screen to remove lumps skin and foreign matter that might enter and clog fluid passages and or spray equipment Follow pressure relief procedure above To add material to the tank remove the lid and pour directly into the tank or container If desired a U S or metric 1 gallon pail of fluid can be placed directly into the tank Replace the lid assembly and tighten thumb screws 17 securely The air supply to the tank should include a filter water separator to filter dirt from the air and remove water and oil Connect the material hose to the fluid outlet ball valve 8 OPERATION 1 Close the air inlet valve to tank Turn handle on regulator counterclockwise until spring tension is relieved Turn on air supply to the tank Open the air inlet valve to the tank Open the fluid outlet valve A U N clockwise to pressurize tank 6
40. re performing equipment maintenance could cause information EH A rj serious injury or death WEAR RESPIRATOR Toxic fumes can cause serious injury or death if inhaled Wear a respirator as recommended by the fluid and solvent manufacturer s Material Safety Data Sheet HIGH PRESSURE CONSIDERATION High pressure can cause serious injury Relieve all pressure before servicing Spray from the spray gun hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury TOXIC FLUID amp FUMES Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin inhaled injected or swallowed LEARN and KNOW the specific hazards or the fluids you are using PRESSURE RELIEF PROCEDURE Always follow the pressure relief procedure in the equipment instruction manual FIRE AND EXPLOSION HAZARD Improper equipment grounding poor ventilation open flame or sparks can cause hazardous conditions and result in fire or explosion and serious injury KEEP EQUIPMENT GUARDS IN PLACE Do not operate the equipment if the safety devices have been removed PROJECTILE HAZARD You may be injured by venting liquids or gases that are released under pressure or flying debris AUTOMATIC EQUIPMENT Automatic equipment may start suddenly without warning ELECTRIC SHOCK GROUNDING Improper grounding or sparks can cause a hazardous condition and result in fire
41. rga est tica que debe ser disipada mediante la debida conexi n a tierra del equipo los objetos que van a ser atomizados y todos los dem s objetos electroconductores en el rea de aplicaci n La conexi n a tierra indebida o las chispas pueden ocasionar condiciones de peligro y producir incendios explosiones o descargas el ctricas y otras lesiones graves USE GAFAS PROTECTORAS No usar gafas protectoras con resguardos laterales puede ocasionar lesiones graves en los ojos o ceguera CONSIGA ATENCI N M DICA INMEDIATA Para evitar el contacto con el fluido tenga en cuenta lo siguiente a Nunca apunte la pistola v lvula hacia ninguna persona ni hacia ninguna parte del cuerpo b Nunca ponga la mano ni los dedos sobre la punta pulverizadora c Nunca trate de detener ni desviar los escapes de fluido con la mano el cuerpo guantes o trapos d Antes de atomizar tenga siempre el resguardo de la punta puesto en la pistola pulverizadora e Antes de atomizar aseg rese siempre de que el seguro del disparador de la pistola est operativo f Cuando deje de atomizar p ngale siempre el seguro al disparador de la pistola ALERTA M DICA Cualquier lesi n ocasionada por l quido de alta presi n puede ser grave Si sufre una lesi n o sospecha haber sufrido una a Vaya a una sala de emergencia de inmediato b Informe al m dico que sospecha haber sufrido una lesi n por inyecci n c Muestre al m dico esta informaci n m dica o
42. rio que se fija entre la v lvula de salida de fluido y la manguera de fluido para filtrar el material Componentes hechos de acero inoxidable con filtro de nylon Viene est ndar con tamiz de malla 100 Para m s informaci n ver SB 7 072 UNIDADES DE CONTROL HFRL 508 HFRL 509 CLEAN AIR Estas unidades est n dise adas para eliminar la suciedad el sarro en los tubos y la mayor a de los aerosoles l quidos Incluye un drenaje autom tico que expulsa los l quidos quese acumulan en la cubeta del filtro 29 3100 SCRUBS TOALLAS PARA LIMPIARSE LAS MANOS Scrubs son toallas para pintores prehumedecidas para limpiarse las manos No se necesita agua 83 2924 Y FILTRO DE FLUIDO Se conecta en la salida de l quido del tanque Incluye 100 malla del filtro Filtro con pantallas de diferentes tamafios de malla est n tambi n disponibles ACCESORIOS REVESTIMIENTO INTERIOR DESECHABLE DE TANQUE Los revestimientos interiores de tanque de polietileno moldeado reducen el desperdicio de solventes y el tiempo de limpieza del tanque El revestimiento interior esta hecho de polietileno a prueba de filtraciones duradero y resistente y se puede usar con todos los materiales compatibles PTL 408 K20 Kit de 20 revestimientos interiores de tanque 9 8 gal PTL 412 K8 Kit de 8 revestimientos interiores de tanque 11 8 gal PTL 415 K10 Kit de 10 revestimientos interiores 19 8 gal FILTROS DE TANQUE A PR
43. tola Ninguna 183G 1523 Doble aire regulado al tanque y la pistola Engranaje reducido reforzado 183G 1530 Extra sensible nica Ninguna 183G 1533 Extra sensible nica Engranaje reducido reforzado 183G 1540 Extra sensible c regulaci n de pistola Ninguna 183G 1543 Extra sensible c regulaci n de pistola Engranaje reducido reforzado Reemplaza Hoja de Hoja de piezas Piezas 77 2928R 4 77 2928R 5 BITMKS En esta Hoja de piezas las palabras ADVERTENCIA PRECAUCI N y NOTA se emplean para enfatizar informaci n de seguridad importante de la manera siguiente PRECAUCI N Pr cticas peligrosas o inseguras que pueden ocasionar lesiones personales leves la muerte da o al producto o a la propiedad A ADVERTENCIA Pr cticas peligrosas o inseguras que pueden Informaci n importante de instalaci n operaci n o mantenimiento ocasionar lesiones personales graves la muerte o da o substancial a la propiedad VERTENCIA Lea las siguientes advertencias antes de usar este equipo LEA EL MANUAL Antes de operar los equipos de acabado lea y comprenda toda la informaci n de seguridad operaci n y mantenimiento incluida en el manual de operaciones CAPACITACI N DE LOS OPERADORES Todos los miembros del personal deben ser capacitados antes de operar los equipos de acabado PELIGRO DE USO INDEBIDO DEL EQUIPO El uso indebido del equipo puede ocasionar aver as mal funcionamiento o activaci n
44. ucir el riesgo de sufrir una lesi n siga el procedimiento de liberaci n de presi n a continuaci n Siempre que el tanque se deje desatendido Antes de intentar quitar el sombrerete del puerto de llenado o la cubierta del tanque Antes de revisar o reparar o dar mantenimiento a cualquier parte del sistema de pulverizaci n 1 Interrumpir el suministro de aire principal al tanque 2 Cerrar la v lvula de entrada de aire ubicada en el colector de aire del tanque 3 Purgar el aire del tanque haciendo girar el tornillo de mariposa de la v lvula de liberaci n de aire 5 en sentido antihorario Esperar hasta que todo el aire haya salido por la v lvula antes de quitar la cubierta del tanque a presi n o el sombrerete del puerto de llenado 4 Dejar abierta la v lvula de liberaci n de aire hasta haber reinstalado la cubierta del tanque o el sombrerete del puerto de llenado S 3 BITMKS CONJUNTOS DE TANQUES GALVANIZADOS DE 10 05 15 GALONES ESPECIFICACIONES Y OPCIONES ESPECIFICACIONES TANQUES GALVANIZADOS Presi n m xima de trabajo 110 psi Casco del tanque Acero SA 414 galvanizado Zinc Tapa del tanque Acero SA 414 galvanizado Zinc Tubo de fluidos Tubo de acero galvanizado 3 8 pulg Salida de fluido codo Acero enchapado en zinc V lvula de fluido salida Lat n niquelado 3 8 18 NPS M Paleta del agitador Propulsor Nylon con refuerzo interior de fi