Home
Pedestal Sump Pump Bomba de pie para sumideros
Contents
1. Pump starts and stops too often Improper positioning of float rod stop Faulty automatic switch Lower float rod stop Replace automatic switch Pump is noisy Improper installation Refer to Installation Noisy motor Replace pump Pump will not stop running Debris around float or float rod stuck Remove debris from sump Check to see float is not rubbing sump wall or float rod rubbing or stuck against sump cover Faulty automatic switch Replace switch Motor defective Replace pump Repair Parts Ref Description Qty Part Number 1 Motor u 2 Switch t 3 Volute Pump Body PS1 25P 4 Impeller PS5 269P 5 Base Plate PS4 17P 6 Screws Base Plate 8 U30 934ZP 7 Float Rod Guide RP0005249 8 Screw Guide Rod U30 929ZP 9 Screw Base SC004 116 10 Float FT0013 63 11 Float Rod RP005168S 12 Float Stop 2 RP0005248 If the motor fails replace the entire pump t Select switch model number below FP0020 FP0018 7D Seguridad Instrucciones importantes de seguridad Guarde estas instrucciones Este manual contiene instrucciones importantes que se deben seguir durante la instalaci n y el mantenimiento del bombas de sumidero A Este es un s mbolo de alerta sobre la seguridad Cuando vea este s mbolo en su bomba o en este manual busque para ver si hay alguna de las siguient
2. 1 Know the pump application limitations and potential hazards A WARNING Risk of fire and explosion Can cause severe injury property damage or death Do not use in explosive atmospheres Pump water only with this pump Failure to ollow this warning can result in personal injury and or property damage Disconnect power before servicing Release all pressure within system before servicing any component 4 Drain all water from system before servicing A CAUTION Risk of flooding Can cause personal injury and or property damage If a flexible discharge hose is used pump may move when motor starts If it moves far enough so that switch hits side of sump switch may stick and prevent pump from starting Make sure pump is secured so it cannot move around in sump 5 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 6 Check hoses for weak or worn condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required AWARNING Risk of fire Do not store or rest objects on or near motor or switch linkage Keep all flammable objects or liquids away from motor 8 Provide means of pressure relief for pumps whose discharge line can be shut off or obstructed 9 Personal Safety a Wear safet
3. Piezas de repuesto a unas 6 16 cm por debajo del motor Instale la guia en la columna con el tornillo provisto A PRECAUCI N Riesgo de inundaci n Puede provocar lesiones personales y o da os materiales Aseg rese de que la gu a est sujetada firmemente 14 AVISO La v lvula de retenci n FP0026 6D se usa con la manguera flexible de descarga viene con un orificio de purga de aire para evitar la creaci n de bolsas de aire en la bomba Si usted usa una v lvula de retenci n sin orificio de purga de aire perfore un orificio de 1 8 pulg 3 2 mm en la tuber a de descarga justo por encima del cuerpo de la bomba pero por debajo de la v lvula de retenci n para evitar la creaci n de bolsas de aire Una vez instaladas todas las tuber as y controles la unidad est lista para funcionar Haga funcionar la bomba durante un ciclo para verificar el funcionamiento del interruptor flotador dh ADVERTENCIA Riesgo de quemaduras y posibles arranques inesperados El motor de la bomba est equipado con un protector t rmico autom tico de restablecimiento y puede volver a arrancar inesperadamente Si el protector salta es una indicaci n de que el motor est sobrecargado porque la bomba est funcionando con baja ca da restricci n de baja descarga voltaje excesivamente alto o bajo cableado el ctrico inadecuado conexiones del motor incorrectas o de que el motor es defectuoso Funcionamiento para
4. Product Warranty Period CL106 CL108 90 days CLTS33P CLSU14 2 Years CLVS50C CLW750 Pressure Tanks 5 Years General Terms and Conditions Limitation of Remedies You must pay all labor and shipping charges necessary to replace product covered by this warranty This warranty does not apply to the following 1 acts of God 2 products which in CountyLine s sole judgement have been subject to negligence abuse accident misapplication tampering or alteration 3 failures due to improper installation operation maintenance or storage 4 atypical or unapproved application use or service 5 failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums This warranty sets forth CountyLine s sole obligation and purchaser s exclusive remedy for defective products COUNTYLINE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to You This warranty gives You
5. cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado e Use guantes de caucho cuando manipule la bomba e Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista e Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminaci n Excepciones para la garant a limitada de doce 12 meses Producto Per odo de garant a CL106 CL108 90 d as CLTS33P CLSU14 2 a os Tanque del sistema de agua CLVS50C CLW750 5 a os T rminos y condiciones generales Limitaci n de recursos Usted deber pagar por todos los gastos de mano de obra y de env o necesarios para reemplazar el producto cubierto por esta garant a Esta garant a no se aplicar en las siguientes situaciones 1 caso de fuerza mayor 2 productos que a s lo juicio de CountyLine hayan sido sometidos a negligencia abuso accidente mala aplicaci n manejo indebido o alteraciones 3 fallas debido a instalaci n operaci n mantenimiento o almacenamiento inadecuados 4 aplicaciones usos o servicios que no sean normales o aprobados 5 fallas provocadas por corrosi n herrumbre u otros materiales extra os en el sistema o una operaci n a presio
6. del flotador atascada Interruptor autom tico defectuoso Retire los residuos del sumidero Verifique que el flotador no roce la pared del sumidero ni que la varilla del flotador roce o est atascada en la tapa del sumidero Reemplace el interruptor Motor defectuoso Reemplace la bomba Piezas de repuesto 13 Ref Descripci n Cant No de piezas 1 Motor 2 Interruptor t 3 Voluta Cuerpo de la bomba PS1 25P 4 Impulsor PS5 269P 5 Placa de base PS4 17P 6 Tornillos Placa de base 8 U30 934ZP 7 Gu a de la varilla de flotaci n RP0005249 8 Tornillo Varilla de flotaci n U30 929ZP 9 Tornillo Base SC004 116 10 Flotador FT0013 63 11 Varilla de flotaci n 1 RP0051685 12 Tope del flotador 2 RP0005248 Si el motor falla reemplace la bomba t Seleccione el n mero del modelo del interruptor a continuaci n Ab FP0018 7D FP0020
7. que la varilla de flotaci n quede en posici n A PRECAUCI N Riesgos de quemaduras No toque vertical y pueda moverse de arriba abajo libremente Si el flotador est inclinado o se dobla la bomba puede no arrancar y provocar inundaciones Enrosque el flotador al extremo con rosca de la varilla La rosca de la varilla cortar la rosca en el 1 flotador anticorrosivo Inserte el otro extremo de la varilla sin rosca en el ojo de la gu a de la varilla Coloque un tope en la varilla de flotaci n antes de pasar la varilla a trav s del ojo del interruptor de 2 la bomba Coloque un segundo tope en la varilla despu s de pasarla a trav s del ojo del interruptor Sit e el segundo tope al mismo nivel que el extremo de la varilla Ubique el tope inferior de la varilla a unas 8 20 cm del brazo de la palanca del interruptor Con el tope inferior de la varilla en esta posici n la bomba tendr ciclos autom ticos de aproximadamente 2 1 2 6 cm afuera y 10 12 25 30 cm adentro Para un ciclo m s r pido sit e el tope inferior de la varilla m s cerca del brazo de la palanca del interruptor Si la tuber a de descarga est expuesta a una atm sfera externa de temperaturas inferiores al punto de congelamiento parte de la tuber a expuesta debe instalarse de manera tal que el agua que permanezca adentro drene a una boca de descarga mediante gravedad Ignorar esta indicaci n puede ocasionar el congelamient
8. GOUNTYLINE TRACTOR SUPPLY Co 293 Wright Street Delavan WI 53115 Phone 1 800 535 4950 Fax 1 800 526 3757 Web Site tractorsupply com Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 7 2011 OWNER S MANUAL Pedestal Sump Pump MANUAL DEL USUARIO Bomba de pie para sumideros Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 535 4950 Espa ol P ginas 8 14 CL263 11 21 11 Safety Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation operation and maintenance of the product Save this manual for future reference A This is the safety alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury indicates a hazard which if not avoided will result in death or serious injury AWARNING indicates a hazard which if not avoided could result in death or serious injury A CAUTION indicates a hazard which if not avoided could result in minor or moderate injury NOTICE addresses practices not related to personal injury Description This Pedestal Sump Pump is designed for home sumps Unit is eq
9. da til de una pieza o del aparato Es necesario retener el recibo de compra original y la etiqueta de informaci n de la garant a a fin de determinar la elegibilidad para la garant a La elegibilidad se basa en la fecha de compra del producto original no en la fecha del reemplazo bajo la garant a La garant a es limitada y cubre solamente la reparaci n o el reemplazo del producto original adquirido no del producto reemplazado es decir que se permite un reemplazo por compra bajo la garant a El comprador pagar todos los costos de remoci n instalaci n mano de obra y env o necesarios as como todo costo adicional asociado Si necesita piezas o resoluci n de problemas NO regrese el producto a la tienda minorista Llame el Servicio a la Clientela de CountyLine al 1 800 535 4950 Las reclamaciones hechas bajo esta garant a se realizar n mediante la devoluci n del producto a excepci n de las bombas cloacales ver a continuaci n al concesionario de venta al p blico en donde se haya adquirido o a la f brica inmediatamente despu s de haber descubierto cualquier presunto defecto CountyLine entonces tomar la medida correctiva tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se reciben m s de 30 d as despu s del vencimiento de esta garant a La garant a no es transferible y no cubre productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba
10. del sistema antes de efectuar el mantenimiento de cualquier componente 4 Drene toda el agua del sistema antes de efectuar areas de mantenimiento A PRECAUCI N Riesgo de inundaci n Puede provocar lesiones personales y o da os materiales Si se utiliza una manguera de descarga flexible puede que la bomba se mueva al encenderse el motor Si al moverse la bomba sta causa que el interruptor roce un lado del sumidero puede que el interruptor se atasque impidiendo que la bomba funcione Cerci rese de que la bomba est bien asegurada para que no choque contra el sumidero 5 Asegure la tuber a de descarga antes de poner en funcionamiento la bomba Si la tuber a de descarga est suelta puede latiguear ocasionando posibles da os personales y o materiales 6 Inspeccione las mangueras antes de usar la bomba para asegurarse de que est n en buen estado y verifique que las conexiones est n firmes 7 Inspeccione mensualmente el sumidero la bomba y los componentes del sistema Mant ngalos libres de residuos y objetos extra os Realice el mantenimiento peri dico que sea necesario ADVERTENCIA Peligro de incendio No guarde ni coloque objetos sobre o cerca del motor o interruptor de enlace Mantenga todo objeto o l quido inflamable lejos del motor 8 Proporcione medios alternativos para liberar la presi n de las bombas cuya tuber a de descarga puede taparse u obstruirse 9 Seguridad personal a Use gafas p
11. e a bajo voltaje cables de extensi n muy largos impulsor apado una ca da muy baja o carga baja etc La desconexi n del protector causar el quemado del motor Localizaci n de fallas A ADVERTENCIA 12 Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Desconecte la bomba de la uente de alimentaci n el ctrica antes de efectuar cualquier rabajo en la misma Sint ma Causa s probable s Acci n correctiva El motor no arranca ni funciona No hay electricidad Inspeccione el fusible el interruptor de circuito el cable de alimentaci n y la toma el ctrica Bajo voltaje en la l nea Si el voltaje del cableado el ctrico est por debajo del m nimo recomendado verifique el tama o de los cables desde la fuente de alimentaci n Si el cableado est bien comun quese con la compa a el ctrica o la autoridad de recursos hidrol gicos Interruptor autom tico defectuoso Accione el interruptor manualmente y reempl celo si no funciona Flotador o varilla del flotador atascados Flotador anegado Aseg rese de que el flotador no roce contra la pared del sumidero y que la varilla del flotador no roce o est atascada contra la tapa del sumidero Reemplace el flotador si est saturado de agua Salt la protecci n de sobrecarga Si la bomba ha estado funcionando y se para antes de vaciar al sumidero el protector de sobrecarga puede haber
12. e con 115 voltios monof sico y est equipado con un cable aprobado de tres conductores y enchufe de tres p as con contacto a tierra Para reducir los riesgos de choque el ctrico aseg rese de que la bomba est conectada a una toma correctamente conectada a tierra Nunca conecte cables verdes o verdes y amarillos a un terminal con corriente Donde haya una toma de pared para enchufes de dos p as deber ser reemplazada por una toma para enchufes de tres p as correctamente conectada a tierra de acuerdo con los c digos y las ordenanzas locales Todas las tareas de cableado deben ser efectuadas por electricistas calificados Aseg rese de que la fuente de energ a concuerda con los requerimientos de su equipo 14 Proteja el cable el ctrico de objetos afilados 15 16 superficies calientes aceites y productos qu micos Evite enredar el cable Reemplace o repare inmediatamente los cables da ados o gastados No toque un motor en funcionamiento Los motores pueden funcionar a temperaturas altas No toque la bomba o el motor de la bomba con as manos mojadas o mientras est parado sobre superficies h medas o mojadas o en el agua dh ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Si su s tano tiene agua o humedad en el piso no camine sobre a superficie h meda hasta que se hayadesconectado a electricidad Si la caja el ctrica est en el s tano lame a la compa a
13. el ctrica para que corte la electricidad de la casa o llame al departamento de bomberos para solicitar instrucciones Retire a bomba y rep rela o reempl cela Ignorar estas instrucciones puede originar choques el ctricos fatales A ADVERTENCIA Riesgo de incendio o de explosi n Puede causar lesiones graves da os materiales o muerte No use la bomba en lugares peligrosos o explosivos 10 Instalaci n te Descarga Ti E Alrededor 00000000 de UL ee 7 Alrededor de 6 Lid V lvula de retenci n adquirir por separado EN Esta unidad puede instalarse en un pozo de sumidero de un m nimo de 12 30 cm de di metro y 12 30 cm de profundidad El pozo de sumidero puede estar construido de azulejos concreto acero o pl stico Verifique los c digos locales para establecer cu les son los materiales aprobados Instale la bomba sobre una base s lida y nivelada an cerca como sea posible del centro del sumidero No cuelgue la bomba de la tuber a de descarga o del cable de alimentaci n A PRECAUCI N Riesgos de quemaduras La bomba debe estar nivelada la columna debe estar vertical mientras funciona Si el motor est inclinado el interruptor interno de arranque funcionamiento puede recalentarse y da ar al motor La bomba no debe ser instalada sobre superficies de arcilla tierra o arena Limpie el sumidero de piedras peque a
14. es palabras de se al y est alerta a la posibilidad de lesiones personales indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad AM ADVERTENCIA indica un riesgo que de no evitarse podr a provocar la muerte o lesiones de gravedad A PRECAUCI N indica un riesgo que de no evitarse podr a provocar lesiones leves o moderadas AVISO hace referencia a una pr ctica no relacionada con una lesi n f sica ez Descripci n Esta Bomba de Pie para Sumideros est dise ada para sumideros dom sticos La unidad est equipada con un cable de alimentaci n de tres p as con contacto a tierra Los cojinetes de manga del eje del motor nunca requieren lubricaci n Protecci n t rmica de restablecimiento autom tico AVISO Esta unidad no ha sido dise ada para uso con agua salada o salubre El uso con agua salada o salubre anular la garant a Especificaciones Energ a el ctrica necesaria Caballos de fuerza 115V 60 Hz Funcionamiento del motor Intermitente Margen de temperatura del guido sessista 32 a 70 F 0 21 C Requiere un ramal individual GFCI Clase A Carga Completa del motor m xima Descarga 15 amps 3 5 amps 1 1 4 FNPT Rendimiento GPH Galones Por Hora LPH Litros Por Hora por total de pies M gt 10pi 15pi 20pi PR 108 4 57 6 09 3000 2460 1620 0 11 355 9 312 6 131 0 Informaciones generale
15. etting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading as a result of operating pump at low heads low discharge restriction excessively high or low voltage inadequate wiring incorrect motor connections or a defective motor Operation A CAUTION Risk of burns Do not touch sump pump pump motor water or discharge piping when pump is connected to electrical power Always disconnect pump cord power before handling 1 Plug this unit into a 115V outlet on an individual branch circuit with a Class A 15 amp GFCI Ground Fault Circuit Interrupter Consult your local electrician for information and availability 2 Fill sump pit with water pump will start automatically when lower rod stop actuates switch lever arm When upper rod stop actuates switch lever arm pump will stop Do not allow pump to run dry AWARNING Risk of electric shock Can shock burn or kill Before attempting to service always disconnect power from unit 3 The motor is equipped with an automatic reset thermal protector to protect unit from overheating When motor has cooled sufficiently switch will reset automatically and restart motor Repeated tripping could be caused by low voltage long extension cords clogged impeller very low head or lift etc Cycling of protector will cause eventual motor burnout Troubleshooting AWARNING Risk of electric shoc
16. he date of replacement under warranty The warranty is limited to repair or replacement of original purchased product only not replacement product i e one warranty replacement allowed per purchase Purchaser pays all removal installation labor shipping and incidental charges For parts or troubleshooting assistance DO NOT return product to your retail store Contact CountyLine Customer Service at 1 800 535 4950 Claims made under this warranty shall be made by returning the product except sewage pumps see below to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect CountyLine will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed e Wear rubber gloves when handling the pump e For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store e Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty
17. k Can shock burn or kill Unplug pump from power receptacle before working on pump Symptom Possible Cause s Corrective Action Motor will not start or run No electrical power Check fuse circuit breaker power cord and electrical outlet Low line voltage If voltage wiring under recommended minimum check size of wiring from main source If OK contact Electric Company or local Hydro authority Faulty automatic switch Float or float rod stuck Operate switch manually and replace if inoperative Check to see float is not rubbing sump wall or float rod rubbing or stuck against sump cover Waterlogged float Replace float if filled with water Motor overload tripped If pump has been running and stops before sump is emptied automatic overload may have tripped Check inlet screen to be sure impeller is not jammed If so free impeller of obstruction Electrical malfunction Check power cord automatic switch and motor Replace faulty parts as needed Motor runs but pump will not pump Inlet clogged Check inlet and clean if needed Discharge line plugged Clear discharge line and check valve for obstruction Low line voltage Refer to Corrective Action on low line voltage above Pump airlocked Drill a 1 8 3 2mm hole in discharge pipe just above pump body but below the check valve Broken impeller or shaft Replace impeller or shaft as needed
18. nes que excedan los m ximos recomendados Esta garant a establece la nica obligaci n de CountyLine y el recurso exclusivo del Comprador con respecto a los productos defectuosos COUNTYLINE NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS LIMITADAS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA E MPL CITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO LAS GARANT AS LIMITADAS QUE ANTECEDEN NO SE EXTENDER N M S ALL DEL PER ODO DE DURACI N INDICADO EN LA PRESENTE Algunos Estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que Usted tambi n tenga otros derechos que pueden variar de un Estado al otro CountyLine 293 Wright Street Delavan WI U S A 53115 Tel fono 1 800 535 4950 Fax 1 800 526 3757 Sitio Web tractorsupply com Seguridad Instalaci n 10 11 12 13 Cuando haga el cableado de una bomba el ctrica observe todos los c digos locales de electricidad y seguridad A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Este equipo es para ser usado nicament
19. o del agua atrapada en la tuber a de descarga lo cual puede a su vez da ar la bomba Instale una v lvula de control interna modelo FP0026 10 para impedir el retroceso de l quidos en direcci n a la bomba una vez que la misma se apaga la bomba el motor de la bomba la tuber a de agua o de descarga cuando la bomba est conectada a la fuente de energ a el ctrica Siempre desconecte el cable de la bomba alimentaci n antes de tocarla Enchufe esta unidad en un tomacorriente de 115 voltios en un ramal individual con un disyuntor de escape a tierra Clase A de 15 amperios Consulte a su electricista local para mayor informaci n y disponibilidad Llene el sumidero con agua La bomba arrancar autom ticamente cuando el tope inferior de la varilla active el brazo de la palanca del interruptor Cuando el tope superior de la varilla active el brazo de la palanca del interruptor la bomba dejar de funcionar AVISO No permita que la bomba funcione sin agua dh ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Antes de intentar reparar la bomba descon ctela siempre de la uente de energ a El motor est equipado con un protector t rmico autom tico de restablecimiento para proteger la unidad de recalentamientos Cuando el motor se haya enfriado lo suficiente el interruptor se reactivar autom ticamente y el motor volver a arrancar Si el interruptor salta repetidamente puede debers
20. ody carefully to avoid stripping or crossing threads NOTICE Do not use ordinary pipe joint compound on plastic pipe or pump Pipe joint compound can attack plastics and damage pump Installation Operation To reduce motor noise and vibrations a short length of rubber hose 1 5 8 41mm I D e g radiator hose can be connected into discharge line near pump using suitable clamps Pump can tip over so be sure to secure it to something solid AWARNING Risk of electric shock Can shock burn or kill Pump is designed for 115V 60 HZ operation and requires an individual branch circuit of 15 amperes capacity It is supplied with a 3 wire cord set with grounding type plug for use in a 3 wire grounded outlet Do not cut off the round grounding prong For safety outlet must always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway or ground wire system Locate Float Rod Guide Ref 7 Repair Parts about 6 16cm below motor Clamp guide to column with screw provided A CAUTION Risk of flooding Can cause personal injury and or property damage Be sure that guide is securely clamped so hat float rod is vertical and can move up and down freely If float is angled or binds pump may not start allowing flooding to occur Screw float onto threaded end of rod Threads on rod will cut threads into corrosion resistant float Insert plain end of floa
21. p motor with wet hands or when standing on wet or damp surface or in water AWARNING Risk of electric shock Can shock burn or kill If your basement has water or moisture on floor do not walk on wet area until all power has been turned off If shut off box is in basement call electric company to shut off service to house or call local fire department for instructions Remove pump and repair or replace Failure to follow this warning can result in fatal electrical shock AWARNING Risk of fire and explosion Can cause severe injury property damage or death Do not use in hazardous or explosive locations Installation Discharge Check Valve Purchase Separately This unit can be installed in sump pit with minimum diameter of 12 30cm and depth of 12 30cm Sump pit may be constructed of tile concrete steel or plastic Check local codes for approved materials Install pump on solid level foundation as near as possible to center of sump pit Do not hang pump from discharge pipe or power cord A CAUTION Risk of burns Pump must be level column must be vertical when operating If motor is tilted internal start run switch may overheat and damage motor Pump should not be installed on clay earth or sand surfaces Clean sump pit of small stones and gravel which could clog the pump Keep pump inlet screen clear Thread discharge pipe into pump b
22. rotectoras en todo momento cuando trabaje con las bombas b Mantenga el rea de trabajo limpia ordenada y bien iluminada retire del lugar las herramientas y equipos que no se usen c Mantenga a los visitantes alejados del rea de trabajo d Haga que su taller sea a prueba de ni os con candados llaves maestras y retirando siempre las llaves de encendido Garant a 9 Retener el recibo original a fin de determinar la elegibilidad para la garant a Garant a limitada Esta Garant a Limitada entra en vigor el 01 de diciembre 2011 y sustituye toda garant a sin fecha o garant a con fecha anterior al 1 de diciembre de 2011 CountyLine le garantiza al comprador consumidor original el Comprador o Usted de sus productos que stos estar n libres de defectos en materiales y en mano de obra por un per odo de doce 12 meses a partir de la fecha de la compra original del consumidor si dentro de los doce 12 meses a partir de la fecha de la compra inicial del consumidor Ser reparado o reemplazado a opci n de la CountyLine sujeto a los t rminos y condiciones establecidos en la presente Tome nota de que esta garant a limitada cubre defectos de manufactura solamente y no el desgaste com n Todos los aparatos mec nicos peri dicamente necesitan repuestos y servicio para un funcionamiento correcto Esta garant a limitada no cubre las reparaciones que se realicen cuando el uso normal haya agotado la vi
23. s o gravilla que puedan tapar la bomba Mantenga limpia la rejilla de entrada de la bomba Atornille la tuber a de descarga en el cuerpo de la bomba evitando cuidadosamente de raspar o torcer las roscas AVISO No utilice compuestos ordinarios para conexiones de tubos sobre el tubo pl stico o la bomba Los compuestos para conexiones de tubos pueden da ar tanto el pl stico como la bomba Instalaci n Funcionamiento 10 11 12 Para reducir el ruido y las vibraciones del motor puede conectarse una manguera de caucho corta 1 5 8 41 mm de di metro interno p ej manguera de radiador a la tuber a de descarga cerca de la bomba empleando grapas adecuadas La bomba se puede volcar tanto aseg rese de que seguro que algo s lido A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte La bomba est dise ada para funcionar con 115V 60 Hz y 13 requiere un ramal individual de 15 amperios de capacidad Viene equipada con un cord n de tres cables y enchufe de tres p as para uso en tomas con contacto a tierra para enchufes de tres p as No corte la p a de contacto a tierra Para mayor seguridad la toma el ctrica siempre debe estar conectada a tierra a un medio conveniente para la electricidad tal como una tuber a de agua enterrada o un canal met lico de cables de conducci n o un sistema de conexi n a tierra Ubique la Gu a de la varilla de flotaci n Ref No 7
24. s sobre seguridad Las bombas de sumidero el ctricas por lo regular duran muchos a os sin sufrir problemas de servicio cuando son instaladas mantenidas y usadas correctamente Sin embargo las situaciones inusuales interrupci n del suministro el ctrico que va a la bomba tierra o suciedad en el sumidero inundaci n superior a la capacidad de la bomba fallas el ctricas y mec nicas etc pueden evitar que su bomba funcione como acostumbra Para evitar posibles da os ocasionados por inundaci n de agua consulte a su representante de ventas sobre la instalaci n de una bomba de sumidero con CA secundaria una bomba de sumidero de respaldo con CD y o una alarma de alto nivel de agua Consulte la Localizaci n de fallas contenida en este manual para informaci n sobre problemas comunes de la bomba de sumidero y soluciones Para mayor informaci n acuda con su representante de ventas o llame al centro de servicio a clientes 1 Inf rmese acerca de las aplicaciones limitaciones y peligros potenciales de la bomba dh ADVERTENCIA Riesgo de incendio o de explosi n Puede causar lesiones graves da os materiales o muerte No utilice la bomba en atm sferas explosivas Utilice esta bomba para bombear agua solamente Ignorar esta advertencia puede ocasionar da os personales y o materiales 2 Desconecte la bomba antes de hacer reparaciones o realizar tareas de mantenimiento 3 Libere la presi n existente dentro
25. saltado Inspeccione la rejilla de entrada para asegurarse de que el impulsor no est atascado Si lo estuviera libere el impulsor de obstrucciones Defecto el ctrico Inspeccione el cable de alimentaci n el interruptor autom tico y el motor Reemplace las partes defectuosas seg n sea necesario El motor funciona pero la bomba no bombea Entrada tapada Inspeccione la entrada y limpiela si fuera necesario Tuber a de descarga tapada Limpie la tuber a de descarga e inspeccione la v lvu la de control para ver si hay obstrucciones Bajo voltaje en la l nea Refi rase a la acci n correctora referente a bajo voltaje en la l nea en la secci n anterior Burbajas de aire en la bomba Taladre un agujero de 3 2 mm 1 8 en la tuber a de descarga justo arriba del cerpo de la bomba pero debajo de la v lvula de retenci n Impulsor o eje quebrado Reemplace el impulsor o el eje seg n sea necesario La bomba arranca y se para demasiado a menudo Ubicaci n incorrecta del tope de la varilla de flotaci n Ubique m s abajo el tope inferior de la varilla del flotador Interruptor autom tico defectuoso Reemplace el interruptor autom tico La bomba es muy ruidosa Instalaci n incorrecta Refi rase las instrucciones de instalaci n Motor ruidoso Reemplace la bomba La bomba no deja de funcionar Residuos alrededor del flotador o varilla
26. specific legal rights and You may also have other rights which vary from state to state CountyLine 293 Wright Street Delavan WI U S A 53115 Phone 1 800 535 4950 Fax 1 800 526 3757 Web Site tractorsupply com Safety Installation 10 When wiring an electrically driven pump ollow all electrical and safety codes as well as most recent National Electrical Code NEC and Occupational Safety and Health Act OSHA AWARNING Risk of electric shock Can shock burn or kill This equipment is only for use on 115 volt single phase and is equipped with an approved 3 conductor cord and 3 prong grounding type plug To reduce risk of electric shock be certain that it is connected to properly grounded grounding type receptacle Never connect green or green and yellow wire in cord to a live terminal Where a 2 prong wall receptacle is encountered it must be replaced with properly grounded 3 prong receptacle installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician Make certain that power source conforms to requirements of your equipment Protect electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking cord Replace or repair damaged or worn cords immediately Do not touch an operating motor Motors can operate at high temperatures Do not handle pump or pum
27. t rod up through eye of rod guide Slide one rod stop on float rod before passing rod through eye of pump switch Slide 2nd rod stop on rod after passing through eye of switch Position 2nd rod stop flush with top of rod Position lower rod stop to within 8 20cm of switch lever arm With lower rod stop in this position pump will automatically cycle at approximately 2 1 2 6cm off and 10 12 25 30cm on For faster cycling move lower rod stop closer to switch lever arm If pump discharge line is exposed to outside subfreezing atmosphere then portion of line exposed must be installed so any water remaining in pipe will drain to outfall by gravity Failure to do this can cause water trapped in discharge to freeze which could result in damage to pump Install an in line check valve part number FP0026 10 to prevent flow backwards through pump after pump shuts off NOTICE Check valve FP0026 6D used with flexible discharge hose is equipped with an air bleed hole to prevent airlocking the pump If using a check valve without an air bleed hole drill a 1 8 3 2mm hole in discharge pipe just above pump body but below the check valve to prevent air locks 13 After all piping and controls have been installed unit is ready for operation 14 Run pump through one cycle to check float switch operation AWARNING Risk of burns and possible unexpected starts The pump motor is equipped with automatic res
28. uipped with a 3 prong grounding type power cord Sleeve bearings on motor shaft never need lubrication Automatic reset thermal protection NOTICE This unit is not designed for applications involving salt water or brine Use with salt water or brine will void warranty Specifications Power supply required 115V 60 HZ Horsepower Motord tyensassessustessuneeauee Intermittent Liquid Temp Range 32 F to 70 F 0 21 C Individual Branch Circuit Required GFCI Class A 15 Amps Motor full load maximum ooccnconicnnoccncncnncinncn 3 5 Amps Discharges iii 1 1 4 FNPT Performance GPH LPH at Total feet m 5 1 52 10 3 05 15 4 57 20 6 09 3000 2460 1620 0 11 355 9 312 6 131 0 General Safety Electrically powered sump pumps normally give many years of trouble free service when correctly installed maintained and used However unusual circumstances interruption of power to the pump dirt debris in the sump flooding that exceeds the pump s capacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible water damage due to flooding consult your retailer about a secondary AC sump pump a DC backup sump pump and or a high water alarm See Troubleshooting in this manual for information about common sump pump problems and remedies For more information see your retailer or call customer service
29. y glasses at all times when working with pumps b Keep work area clean uncluttered and properly lighted replace all unused tools and equipment c Keep visitors at a safe distance from work area d Make workshop child proof with padlocks master switches and by removing starter keys Ww N Warranty 3 Retain Original Receipt For Warranty Eligibility Limited Warranty This Limited Warranty is effective December 1 2011 and replaces all undated warranties and warranties dated before December 1 2011 CountyLine warrants to the original consumer purchaser Purchaser or You that its products are free from defects in material and workmanship for a period of twelve 12 months from the date of the original consumer purchase lf within twelve 12 months from the original consumer purchase any such product shall prove to be defective it shall be repaired or replaced at CountyLine s option subject to the terms and conditions set forth herein Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear All mechanical devices need periodic parts and service to perform well This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment The original purchase receipt and product warranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not t
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation - Smokeless || Première cigarette électronique Manual Dermotonus Esthetic NEC LH19m 19" LCD Display descargar la hoja de especificaciones técnicas - Sea-Doo Samsung 23" SyncMaster SB550V LS23B550VS/EN Bruksanvisning MEN Mikro P511 Manual HPs x20LED-, x22LED-, x22LEDc- und x23LED Products Covered by This Manual Copyright © All rights reserved.