1. e A yellow LED indicates a 50 to 75 charge The Instant Power may be used but should be recharged as soon as possible e A green LED indicates the internal battery is fully charged Charging the Internal Battery using the Built In Charger 1 To charge flip the charger plug on the back of the Instant Power up and plug an 18 gauge AWG or larger extension cord onto it Extension cord not included must be purchased separately Plug the extension cord into a 120V AC electrical wall outlet The RED LED will glow indicating charging The GREEN LED will light when the battery has reached full charge This could take up to 72 hours due to the age and condition of the battery The charger will automatically go into maintain mode and maintain the battery at full charge without damaging it 5 Charge the Instant Power as soon as possible after use IMPORTANT Do not use the Instant Power while charging the internal battery US You may also charge the internal battery while driving using the male to male charger cable p n 94500109 not included Insert one end of the accessory cable into the 12V DC power outlet and the other end into the vehicle s accessory outlet lighter socket Completely disconnect the charger cable when the engine is not running IMPORTANT The RED LED and the GREEN LED do not operate during this method of charging Using this method to charge the battery overrides the maintain mode and th
2. Battery Status Indicators Battery Status Switch Built In Worklight Worklight ON OFF Switch 12V DC Power Outlet Internal Battery Charger Plug not shown 7 Battery Clips Oona WN XP500 Battery Status Indicators Battery Status Switch Built In Worklight Worklight ON OFF Switch 12V DC Power Outlet Internal Battery Charger Plug not shown Battery Clips USB ON OFF Switch USB Port 9 Battery Clips Oona WN co N XP750C Battery Status Indicators Battery Status Switch 12V DC Power Outlet Internal Battery Charger Plug not shown Battery Clips USB ON OFF Switch USB Port Built In Worklight Worklight ON OFF Switch Air Compressor ON OFF Switch not shown 10 Air Compressor Gauge not shown 11 Air Compressor Hose 12 Air Compressor Hose Wrap Cleats not shown 13 Air Compressor Adapters and Storage Bag not shown 14 Battery Clips ON O 0 JO 0 7 1 7 2 CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER IMPORTANT CHARGE IMMEDIATELY AFTER PURCHASE AFTER EACH USE AND EVERY 30 DAYS TO KEEP THE INSTANT POWER INTERNAL BATTERY FULLY CHARGED LED Indicators TO CHECK THE INTERNAL BATTERY S CHARGE STATUS PRESS THE BATTERY STATUS BUTTON ON THE FRONT OF THE INSTANT POWER The LED lights will indicate the charge level as follows e Ared LED indicates a 50 or less charge and you should immediately recharge the Instant Power
3. 5 Accione la palanca del interruptor de la l mpara a la posici n de apagado una vez terminada la operaci n 6 Cargue el Instant Power tambi n tan pronto sea posible despu s de usar la luz NOTA Con la bater a interna completamente cargada la luz integrada del XP400 debe proporcionar aproximadamente 50 horas de luz continua la luz integrada en el XP500 debe proporcionar aproximadamente 70 horas de luz continua y la luz integrada en el XP750C debe proporcionar aproximadamente 120 horas de luz continua Uso del Compresor de Aire Modelo XP750C dh ADVERTENCIA Riesgo de explosi n Antes de usar el compresor lea las instrucciones del objeto a inflar Evite sobre inflar no exceda la presi n de aire recomendado por el fabricante Durante el uso no desatienda el compresor NOTA Antes de que usted utilice el compresor por primera vez debe instalar los sujetadores de la manguera del compresor Para instalar Presione cada sujetador en los orificios de montaje correspondientes en la parte trasera del arrancador hasta que queden sujetos en sus sitior Enrolle la manguera del compresor alrededor de los sujetadores cuando no se est utilizando 1 Aseg rese que las pinzas est n fijas en el compartimiento 2 Quite la manguera de los sujetadores del compresor de aire situada en la parte de atr s el Instant Power instale adaptadores si es necesario 3 Sujete la manguera del compresor al producto o aparato a ser inf
4. City State Zip Code Phone Email Store Name Where Purchased Date of Purchase Store Location UPC Number Serial Number SEE PRODUCT a e e ds a ea 15 16 IMPORTANTE LEA Y GUARDE ESTE MANUAL DE INSTRUCCIONES Y SEGURIDAD GUARDE ESTAS INSTRUCCIONES Cargue el Instant Power inmediatamente despu s de comprarla despu s de cada uso y cada 30 d as Este manual le mostrar c mo utilizar su cargador en forma segura y efectiva Por favor lea comprenda y siga estas instrucciones y precauciones cuidadosamente ya que este manual contiene instrucciones operativas y de seguridad de importancia Los mensajes de seguridad representados en este manual contienen palabras gu a un mensaje y una figura La palabra gu a indica el nivel de peligro en determinada situaci n A PELIGRO Indica una inminente situaci n de riesgo que si no se evita resultar a mortal o de serios perjuicios al operador o personas alrededor Indica una situaci n potencialmente riesgoso que si no se evita dh ADVERTENCIA podr a resultar o de serios perjuicios al operador o personas alrededor Indica una situaci n potencialmente riesgoso que si no se evita podr a resultar o de serios perjuicios al operador o personas alrededor A ATENCI N Indica una situaci n potencialmente peligrosa que de no evitarse IMPORTANTE podr a causar da o al equipo al veh culo y propiedades alrededor Los mensajes estipulados en este manual
5. The USB port provides up to 500mA at 5V DC Ensure the battery clips are securely clipped on the storage holders Turn the Instant Power On Off switch to the ON clockwise position Plug the device into the USB port on the front panel Turn the USB device on Reverse these steps when finished using the USB port Charge the Instant Power as soon as possible after using the USB port 8 4 Usina the Built In Light 1 Position the Instant Power on a flat stable surface near the intended work area Ensure the battery clips are securely clipped on the storage holders Toggle the Work Light switch to the ON position The Instant Power light will turn on and illuminate your work area Toggle the Work Light switch to the OFF position when the work is completed aa the Instant Power as soon as possible after using the built in ight NOTE With a fully charged internal battery the built in light on the XP400 should provide approximately 50 hours of continuous useful light the built in light on the XP500 should provide approximately 70 hours of continuous useful light and the built in light on the XP750C should provide approximately 120 hours of continuous useful light Peeve oP amp P 8 5 Using the Air Compressor Model XP750C AWARNING Risk of explosion Read the instructions of the product being inflated before using the compressor Avoid over inflation do not exceed the manufacturer s recommended pressures D
6. area or surface where damage could occur if the internal battery should unexpectedly leak acid 10 5 IMPORTANT e CHARGE IMMEDIATELY AFTER PURCHASE e KEEP FULLY CHARGED Charge the Instant Power internal battery immediately after purchase after every use and every 30 days All batteries are affected by temperature The ideal storage temperature is at 70 degrees Fahrenheit The internal battery will gradually self discharge lose power over time especially in warm environments Leaving the battery in a discharged state may result in permanent battery damage To ensure satisfactory performance and avoid permanent damage charge the internal battery every month 11 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REASON SOLUTION The Instant Power won t Clips are not making a good Check for poor connection jump start my car connection to the battery to battery and frame Make sure connection points are clean Rock clips back and forth for a better connection Connections are reversed Disconnect the Instant Power and reverse the clips The Instant Power battery Check the battery charge is not charged status by pressing the button on the front of the Instant Power See LED Indicators section of this manual The vehicle s battery is Have the battery checked defective 10 PROBLEM POSSIBLE CAUSE REASON SOLUTION The Instant Power won t The 12V device is not Turn on the 12V device power my
7. de garant a impl cita por lo que las limitaciones o exclusiones mencionadas anteriormente podr an no corresponder con su caso La presente garant a le otorga derechos legales espec ficos y es probable que usted cuente con otros derechos que podr an diferir de los incluidos en la presente garant a LA PRESENTE GARANT A LIMITADA ES LA NICA GARANT A LIMITADA EXPRESA Y EL FABRICANTE NO ASUME NI AUTORIZA A NADIE A ASUMIR O A ADQUIRIR NINGUNA OTRA OBLIGACI N RESPECTO DEL PRODUCTO QUE NO SEA LA PRESENTE GARANT A Servicio de atenci n al cliente de Schumacher Electric Corporation 1 800 621 5485 Lunes viernes 7 00 a m a 5 00 p m CST Schumacher y el logo Schumacher son maracas registradas de Schumacher Electric Corporation Para hacer efectiva la garat a por favor llene la tarjeta de garant a en p gina 15 y ev ela O visite la p gina de internet www batterychargers com para registrar su producto en la red NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Llame a Servicios al Cliente para Asistencia 800 621 5485 30 31 DO NOT RETURN THIS PRODUCT TO THE STORE Call Customer Service for Assistance 800 621 5485 NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Llame a Servicios al Cliente para Asistencia 800 621 5485
8. 12V device turned on The Instant Power battery Check the battery charge is not charged status by pressing the button on the front of the Instant Power See LED Indicators section of this manual The 12V device draws more Disconnect the 12V device than 15A or has a short The internal breaker will circuit automatically reset after a minute or two Try the 12V device again If it happens again replace the 12V device The battery in the Instant The battery is bad will not Have the battery checked Power won t hold a accept a charge charge If the above solutions do not eliminate the problem or for information about troubleshooting or replacement parts call toll free from anywhere in the U S A 1 800 621 5485 7 00 am to 5 00 pm Central Time Monday through Friday 12 SPECIFICATIONS Model XP400 Internal Battery Type Sealed Maintenance Free AGM Lead Acid Nominal Voltage 12V DC 4 DC Power Output Maximum Continuous Load Battery Hookup Cables with Clamps 8 gauge AWG 18 45 72 cm Long Dimensions H x W x D 10 x 10 25 x 5 25 25 4 cm x 26 cm x 13 3 cm Weight 7 lbs 3 18 kg 15A 16 e 11 DC Power Output Maximum Continuous Load Continuous Load 13 14 REPLACEMENT PARTS ACCESSORIES Male To Male Accessory Cable 94500109 LIMITED WARRANTY SCHUMACHER ELECTRIC CORPORATION 801 BUSINESS CENTER DRIVE MOUNT PROSPECT IL 60056 217
9. A lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn Be sure the area around the battery is well ventilated while the jump starter is being used RISK OF CONTACT WITH BATTERY ACID 2 9 2 10 2 11 2 12 2 13 2 14 2 15 2 16 2 17 BATTERY ACID IS A HIGHLY CORROSIVE SULFURIC ACID Consider having someone close enough by to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts your skin clothing or eyes Wear complete eye and body protection including safety goggles and protective clothing Avoid touching your eyes while working near the battery If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately flood the eye with cold running water for at least 10 minutes and get medical attention right away If battery acid is accidentally swallowed drink milk the whites of eggs or water DO NOT induce vomiting Seek medical attention immediately Stay clear of fan blades belts pulleys and other parts that may cause injury Clean the battery terminals before using the jump starter During cleaning keep airborne corrosion from coming into contact with your eyes nose and mouth Use baking soda and water to neutralize the battery acid and help eliminate airborne corrosion Do not touch your ey
10. Conecte a una pieza met lica de calibre grueso del marco o del bloque motor Al desconectar el Instant Power apague todos los interruptores si es aplicable retire el gancho del chasis del veh culo y luego retire el gancho del terminal perteneciente a la bater a 20 4 4 1 CONEXIONES A TIERRA Y ENERG A DE CA ADVERTENCIA EL RIESGO DE DESCARGA EL CTRICA O INCENDIO El enchufe del cargador interno del Instant Power est destinado a un uso en un circuito con tensi n nominal de 120 V La extensi n utilizada con el enchufe del cargador interno debe enchufarse en un tomacorriente propiamente instalado y aprobado por c digos y normas locales Los pasadores del enchufe deben adaptarse al recept culo tomacorriente No utilizar con un sistema que no posea descarga a tierra INSTRUCCIONES DE MONTAJE Desenrede todos los cordones y extienda los cables antes de usar el Instant Power CARACTER STICAS a IN aa XP400 Indicadores del estado de la bateria Interruptor del estado de la bateria Lampara integrada Con interruptor de APAGADO ENCENDIDO para lampara Salida de energia de CC de 12V Enchufe interno del cargador de bateria no mostrado Pinzas de la bateria XP500 Indicadores del estado de la bateria Interruptor del estado de la bateria Lampara integrada Con interruptor de APAGADO ENCENDIDO para lampara Salida de energia de CC de 12V Enchu
11. contact the same piece of metal Never attempt to jump start a frozen battery Powering a 12V DC Device The Instant Power is a power source for all 12V DC accessories that are equipped with a 12V accessory plug Use it for power outages and fishing or camping trips Estimated usage time is listed in the chart below Make sure the device to be powered is OFF before inserting the 12V DC accessory plug into the 12V DC accessory outlet 1 Ensure the battery clips are securely clipped on the storage holders 2 Open the protective cover of the DC power outlet on the front of the Instant Power 3 Plug the 12V DC device into the DC power outlet and turn the 12V DC device on if required 4 Ifthe 12V DC device draws more than 15A or has a short circuit the internal circuit breaker of the Instant Power will trip and disconnect the power to the device Disconnect the 12V DC device The breaker will automatically reset after an overload occurs The DC power outlet is wired directly to the internal battery Extended operation of a 12V DC device may result in excessive battery drain Recharge immediately after unplugging the 12V DC device Estimated Estimated Estimated Estimated Appliance Type Wattage Usage Time Usage Time Usage Time 9 XP400 XP500 XP750C Car Vacuum Air NOTE Estimated run times Actual time may vary Times are based on the internal battery being fully charged 8 3 Using the USB Port Models XP500 and XP750C
12. se describen dos tipos de estilo e Los que aparecen sin n mero indican el riesgo e Aquellos que aparecen numerados indican c mo evitar los riesgos La figura muestra una descripci n gr fica del potencial de riesgo A ADVERTENCIA 43 Conforme a la Propuesta 65 de California este producto contiene qu micos de los cuales en el Estado de California se tiene conocimiento que provocan c ncer y malformaciones cong nitas u otras lesiones reproductivas e 17 dE 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones operativas y de seguridad de importancia EL RIESGO DE DESCARGA EL CTRICA O INCENDIO Lea el manual completo antes de utilizar este producto Cualquier falla podr a resultar en serias lesiones o podr a ser mortal Mant ngase alejado de los ni os Utilice solamente accesorios recomendados El uso de un accesorio no recomendado o suministrado por Schumacher Electric Corporation puede provocar riesgo de incendio descarga el ctrica o lesiones a personas o da o a la propiedad No coloque los dedos o las manos en cualquiera de los enchufes del Instant Power M No exponga el Instant Power a la lluvia o la nieve El uso de una extension inapropiada para cargar el Instant Power puede resultar muy riesgozo incendio y corto electric Aseg rese de que e Los pasadores en el enchufe d
13. 9 MAKES THIS LIMITED WARRANTY TO THE ORIGINAL RETAIL PURCHASER OF THIS PRODUCT THIS LIMITED WARRANTY IS NOT TRANSFERABLE OR ASSIGNABLE Schumacher Electric Corporation the Manufacturer warrants this Instant Power for one year and the internal battery for ninety days from the date of purchase at retail against defective material or workmanship that may occur under normal use and care If your unit is not free from defective material or workmanship Manufacturers obligation under this warranty is solely to repair or replace your product with a new or reconditioned unit at the option of the Manufacturer It is the obligation of the purchaser to forward the unit along with mailing charges prepaid to the Manufacturer or its authorized representatives in order for repair or replacement to occur e 10 Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corporation and approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a particular purpose Further Manufa
14. C E U Kumain o T E 1 OWNER S MANUAL MANUAL DEL USUARIO Model Modelo XP400 XP500 XP750C XP750C INSTANT POWER Jump Starter and DC Power Source Fuente de Poder de CD y Arrancador e READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH e LEA EL MANUAL COMPLETO ANTES DE UTILIZAR ESTE PRODUCTO CUALQUIER FALLA PODR A RESULTAR EN SERIAS LESIONES O PODR A SER MORTAL 00 99 001047 0710 DO NOT RETURN THIS PRODUCT TO THE STORE Call Customer Service for Assistance 800 621 5485 NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Llame a Servicios al Cliente para Asistencia 800 621 5485 TABLE OF CONTENTS SECTION IMPORTANT SAFETY INSTRUCTIONS PERSONAL PRECAUTIONS FOLLOW THESE STEPS WHEN CONNECTING TO A BATTERY GROUNDING AND AC POWER CORD CONNECTIONS ASSEMBLY INSTRUCTIONS FEATURES CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS MOVING AND STORAGE INSTRUCTIONS TROUBLESHOOTING SPECIFICATIONS REPLACEMENT PARTS ACCESSORIES LIMITED WARRANTY NDICE SECCI N INSTRUCCIONES IMPORTANTES DE SEGURIDAD PRECAUCIONES PERSONALES SIGA ESTOS PASOS CUANDO SE CONECTE A LA BATER A CONEXIONES A TIERRA Y ENERG A DE CA INSTRUCCIONES DE MONTAJE CARACTER STICAS PARA CARGAR LA BATERIA INTERNA DE LA FUENTE DEL INSTANT POWER INSTRUCCIONES DE OPERACI N INSTRUCCIONES DE MANTENIMIENTO INS
15. ITED e WARRANTY PROGRAM REGISTRATION MODEL DESCRIPTION This is the only express limited warranty and the manufacturer neither assumes nor authorizes anyone to assume or make any other obligation There is no other warranty other than what is described in the product owner s manual The warranty card should be submitted within 30 days of purchase The customer must keep the ORIGINAL receipt because it will be required for any warranty claims This warranty is not transferable Mail To Schumacher Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name Street Address City State Zip Code Phone Email Store Name Where Purchased Date of Purchase Store Location UPC Number Serial Number SEE PRODUCT ER SEE C 2 Y 1 YEAR LIMITED l WARRANTY PROGRAM REGISTRATION MODEL DESCRIPTION This is the only express limited warranty and the manufacturer neither assumes nor authorizes anyone to assume or make any other obligation There is no other warranty other than what is described in the product owner s manual The warranty card should be submitted within 30 days of purchase The customer must keep the ORIGINAL receipt because it will be required for any warranty claims This warranty is not transferable Mail To Schumacher Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name Street Address
16. RGADA Cargue el Instant Power inmediatamente despu s de comprarla despu s de cada uso y cada 30 d as La temperatura afecta a todas las bater as La temperatura ideal de almacenaje es a los 70 grados Fahrenheit La bater a interna se va descargando pierde potencia con el pasar del tiempo especialmente en los ambientes c lidos Si se deja la bater a en estado de descarga puede sufrir da os permanentes Para asegurar el rendimiento satisfactorio y evitar da os permanentes cargue la bater a interna mensualmente 26 11 LOCALIZACI N Y SOLUCI N DE PROBLEMAS PROBLEME CAUSE POSSIBLE RAISON SOLUTION La fuente de poder no Las pinzas no hacen buena Aseg rese de que existe arranca mi auto conexion a la bateria buena conexion a la bateria y la carroceria Tambi n que los puntos de las conexiones est n limpios Gire las pinzas para una conexion efectiva Las conexiones estan a la Desconecte La Fuente de inversa poder y coloque las pinzas en forma correcta La bateria de la fuente de Verifique la condicion de poder no esta cargada carga de la bateria girando el interruptor situado enfrente de la fuente de poder Consulte la seccion de Indicadores LED en este manual La bateria del vehiculo esta Haga un chequeo de la defectuosa bateria La Fuente de poder no El aparato de 12V no Allumez le 12V la machine pone a funcionar mi enciende Encienda el aparato de 12V aparato de 12V La bater a de La Fue
17. TE La luz LED ROJA y la luz LED VERDE no funcionan durante este m todo de carga El uso de este m todo de carga invalida el modo de mantenimiento y la bater a puede sobrecargarse Monitoree el progreso de carga de la bater a y cuando alcance la carga completa 100 desconecte el cargador No abandone la bater a pues esto podr a causar serios da os a la propiedad o lesiones personales 8 INSTRUCCIONES DE OPERACI N 8 1 Para arrancar el motor del veh culo IMPORTANTE interna 1 Apague el veh culo antes de hacer conexiones de cables 2 Conecte el Instant Power a la bater a siguiendo las precauciones se aladas en la secci n 3 No utilice el Instant Power mientras carga la bater a Riesgo de Explosi n Si ha conectado las pinzas al rev s en Modelo XP750C escuchar un sonido de alarma NO gire el bot n interruptor a la posici n de ENCENDIDO ON en el sentido de las agujas del reloj Esto podr a causar serios da os al Instant Power o al veh culo Conecte los cables a la inversa y el zumbido dejar de sonar NOTA Los modelos XP400 y XP500 no tienen sonido de alarma 3 Arranque el motor Si el motor no da marcha de entre los 5 y 8 segundos detenga el arranque y espere 1 minuto antes de intentar arrancarlo de nuevo Esto permitir a la bater a que se recupere 4 Una vez que el motor haya arrancado gire el interruptor a la posici n de ENCENDIDO APAGADO a la izquierda modelos XP500 y XP750C des
18. TRUCCIONES PARA EL MANEJO Y ALMACENAMIENTO LOCALIZACI N Y SOLUCI N DE PROBLEMAS ESPECIFICACIONES REPUESTOS ACCESORIOS GARANT A LIMITADA PAGE N O oO A Bb OOD PAGINA 18 19 20 21 21 2 22 23 26 26 27 28 29 29 CONTAINS SEALED NON SPILLABLE LEAD ACID BATTERY MUST BE DISPOSED OF PROPERLY CONTIENE UNA BATER A SELLADA DE CIDO PLOMO NO DERRAMABLE QUE DEBE DESECHARSE APROPIADAMENTE WARNING Possible explosion hazard Contact with battery acid may cause severe burns and blindness Keep out of reach of children ADVERTENCIA Posible Riesgo de una explosi n El contacto con una bater a de cido puede causar quemaduras y ceguera Mant ngase alejado de los ni os IMPORTANT READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS Charge the Instant Power internal battery immediately after purchase after every use and every 30 days This manual will show you how to use your Instant Power safely and effectively Please read understand and follow these instructions and precautions carefully as this manual contains important safety and operating instructions The safety messages used throughout this manual contain a signal word a message and an icon The signal word indicates the level of the hazard in a situation Indicates an imminently hazardous situation which if not avoided will result in death or serious injury to the operator or bystanders Indicates a potentially haza
19. aci n en exceso del aparato de 12V de CD podr a descargar la bater a excesivamente Recargue inmediatamente despu s de desenchufar en aparato de 12V de CD Tipo de Carga Tiempo Tiempo Tiempo a estimada Aproximado Aproximado Aproximado Electrodomestico en Watts de uso XP400 de uso XP500 de uso XP750C Videoc mara Herramienta El ctrica 24 watts 6 horas Refrigerador El ctrico 48 watts 3 horas Aspiradora de Auto NOTA Tiempo aproximado de uso El tiempo actual podr a variar El tiempo est basado en carga total de la bater a interna 8 3 El uso de Puerto USB Modelos XP500 y XP750C El puerto USB provee poco m s de 500 mA por V de CD 1 Aseg rese que las pinzas est n fijas en el compartimiento 2 Gire la perilla de Apague y encienda ON OFF del Instant Power a la posici n ON en el sentido de las agujas del reloj Conecte el aparato en el puerto USB situado en el panel del frente Encienda el aparato USB Una vez terminado el uso del USB desconecte en forma reversible Cargue el Instant Power tan pronto deje de usar el puerto USB E SS e 24 o 8 4 8 5 Uso de la Luz adjunta 1 Coloque la Fuente de Poder sobre una superficie plana cerca del rea de trabajo 2 Aseg rese que las pinzas est n fijas en el compartimiento 3 Accione la palanca del interruptor de la l mpara a la posici n de encendido 4 La luz de el Instant Power encender e iluminar su rea de trabajo
20. casa del Instant Power Aseg rese de que todas las piezas del Instant Power est n bien instaladas y en buenas condiciones para su funci n incluyendo los protectores de pl stico de las pinzas de la bater a Para realizar mantenimiento no es necesario abrir la unidad ya que no existen piezas a las cuales puede realizarle mantenimiento el usuario Cualquier otro servicio debe realizarse por personal calificado en el ramo INSTRUCCIONES PARA EL MANEJO Y ALMACENAMIENTO Guarde el Instant Power desenchufado en posici n vertical El cable seguir conduciendo electricidad hasta que se desenchufe del toma Almacene en el interior en un lugar fresco y seco No guarde los ganchos en asas enganchados entre s en o cerca de metales o enganchados en cables Los ganchos en el Instant Power est n vivas y producen arco o chisporroteo si hacen contacto entre s Para evitar arco accidental siempre mantenga los ganchos en los soportes de almacenaje y el conmutador JUMP START ON OFF en la posici n OFF cuando el Instant Power no se est usando para arranque inmediato de un veh culo Si el Instant Power se mueve alrededor del taller o se transporta a otra localidad trate de evitar prevenir da o a los cables pinzas y al Instant Power El ignorar estas recomendaciones podr a llegar a causarle da os personales o de inmueble IMPORTANTE CARGUE INMEDIATAMENTE DESPU S DE CADA USO MANTENGA LA UNIDAD COMPLETAMENTE CA
21. ceso de arranca aseg rese que el cofre no toque parte met lica de la bater a o pele los cables Mant ngase alejado de las paletas del ventilador correas poleas y otras piezas que podr an provocar lesiones Verifique la polaridad de los bornes de la bater a El borne POSITIVO POS P de la bater a generalmente posee un di metro mayor al borne NEGATIVO NEG N Determine qu borne de la bater a hace descarga a tierra se encuentra conectado con el chasis Si el borne negativo hace descarga a tierra con el chasis como en la mayor parte de los veh culos ver el paso 3 6 Si el borne positivo hace descarga a tierra con el chasis ver el paso 3 7 En un veh culo con descarga a tierra por borne negativo conecte el gancho POSITIVO ROJO del Instant Power al borne POSITIVO POS P sin descarga a tierra de la bater a Conecte el gancho NEGATIVO NEGRO al chasis del veh culo o al bloque motor alejado de la bater a No conecte el gancho al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor En un veh culo con descarga a tierra por borne positivo conecte el gancho NEGATIVO NEGRO del Instant Power al borne NEGATIVO NEG N sin descarga a tierra de la bater a Conecte el gancho POSITIVO ROJO al chasis del veh culo o al bloque motor alejado de la bater a No conecte al carburador l neas de combustible o cuerpos met licos
22. conecte la pinza negra y despu s la roja en ese orden 5 Cargue el Instant Power tan pronto sea posible despu s de usarse AA ADVERTENCIA Riesgo de explosi n Para prevenir chispas NUNCA permita que las pinzas hagan contacto entre s mismas o por medio de un metal Nunca intente arrancar un a bater a congelada 23 8 2 Para hacer funcionar un aparato de 12V de CD El Instant Power es una fuente de poder para cualquier accesorio de 12V de corriente directa que est n equipados con enchufe de 12V Utilicelo durante apagones pesca o d as de campo El tiempo aproximado de uso se describe en la siguiente gr fica Aseg rese que el aparato a conectarse se encuentre en la posici n de APAGADO antes de conectarlo a la fuente de poder de 12V de CD 1 Tambi n aseg rese de que las pinzas queden sujetas en su lugar 2 Abra la tapa protectora de entrada del aparato de CD en la frente del Instant Power 3 Conecte el aparato de 12V de CD en la salida de corriente de la fuente de poder y enci ndalo si requiere 4 Si el aparato de 12 V de CD absorbe m s de 15 A o tiene un corto circuito el interruptor de circuitos interno del Instant Power se reactivar e interrumpir el paso de corriente al aparato Desconecte el aparato de 12V de CD El mismo interruptor se reactivar autom ticamente despu s de que una sobrecarga ocurra El enchufe est conectado directamente a la bater a interna Una oper
23. cturer shall not be liable for any incidental special or consequential damage claims incurred by purchasers users or others associated with this product including but not limited to lost profits revenues anticipated sales business opportunities goodwill business interruption and any other injury or damage Any and all such warranties other than the limited warranty included herein are hereby expressly disclaimed and excluded Some states do not allow the exclusion or limitation of incidental or consequential damages or length of implied warranty so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and it is possible you may have other rights which vary from this warranty THIS LIMITED WARRANTY IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES OR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS WARRANTY Schumacher Electric Corporation Customer Service 1 800 621 5485 Monday Friday 7 00 a m to 5 00 p m CST Schumacher and the Schumacher Logo are registered trademarks of Schumacher Electric Corporation To activate the warranty please fill in the warranty registration card on page 15 and mail it in OR go to www batterychargers com to register your product online DO NOT RETURN THIS PRODUCT TO THE STORE Call Customer Service for Assistance 800 621 5485 13 e 140 C 2 lt S Y 1 YEAR LIM
24. delo XP750C Tipo Interno de la Bater a e rd de mantenimiento AGM de Volaje Nominal De CC y 12V Capacidad Salida de Energ a de CC Carga M xima Cont nua Amperaje M ximo Amperaje de Arranque Amperaje de Arranque en fr o e de Conexi n de Bater a con calibre 8 AWG 20 5 52 5 cm de Largo Dimensiones AxA x P 10 5 x 13 5 x 10 25 26 7 cm x 34 3 cm x 26 cm Peso 13 14 19 85 Ibs 9 kg REPUESTOS ACCESORIOS Cable accesorio macho a macho 94500109 GARANT A LIMITADA SCHUMACHER ELECTRIC CORPORATION 801 BUSINESS CENTER DRIVE MOUNT PROSPECT IL 60056 2179 REALIZA LA PRESENTE GARANTIA LIMITADA AL COMPRADOR MINORISTA ORIGINAL DE ESTE PRODUCTO LA PRESENTE GARANT A LIMITADA NO PUEDE TRANSFERIRSE NI CEDERSE Schumacher Electric Corporation el Fabricante otorga garant a por esta unidad por un a o y la bater a interna por noventa d as contados a partir de la fecha de compra contra cualquier material defectuoso o de mano de obra de la unidad que pudieran surgir durante su uso y bajo cuidado normal Si su unidad cuenta con material defectuoso o defectos de mano de obra la obligaci n de los Fabricantes conforme a la presente garant a ser simplemente reparar o sustituir el producto por uno nuevo o por una unidad reparada a elecci n del fabricante Es obligaci n del comprador enviar la unidad junto con los gastos de env o prepagado al fabricant
25. e battery can be overcharged Monitor the progress of the battery and when it reaches a full 100 charge disconnect the charger Do not leave the battery unattended or it could explode causing property damage or personal injury 8 8 1 OPERATING INSTRUCTIONS Jump Starting a Vehicle Engine IMPORTANT Do not use the Instant Power while charging the internal battery 1 Turn the vehicle s ignition OFF before making cable connections 2 Connect the Instant Power to the battery following the precautions listed in section 3 Risk of Explosion AWARNING if you have connected the clips backwards on Model XP750C an audio alarm will sound DO NOT turn the ON OFF switch to the ON clockwise position This could cause serious damage to the Instant Power or the vehicle Reverse the connections and the audio alarm will stop NOTE Models XP400 and XP500 do not have an audio alarm 3 Crank the engine If the engine does not start within 5 8 seconds stop cranking and wait at least 1 minute before attempting to start the vehicle again This permits the battery to cool down 4 After the engine starts turn the On Off switch to the OFF counterclockwise position models XP500 and XP750C disconnect the black clip and then the red clip in that order 5 Recharge the Instant Power as soon as possible after use AWARNING Risk of Explosion To prevent sparking NEVER allow the clips to touch together or to
26. e o a sus representantes autorizados para que sta se pueda reparar o reemplazar El Fabricante no presta garant a por lo accesorios utilizados con este producto que no sean los fabricados por Schumacher Electric Corporation y que no est n aprobados para su uso con este producto La presente Garant a Limitada ser nula si el producto se utiliza en forma err nea se trata de manera inadecuada es reparado o modificado por personas que nos sean el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresas impl citas o legales incluidas a modo de ejemplo las garant as impl citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no ser responsable ante reclamos por da os accidentales especiales ni directos en los que incurran los compradores usuarios u otras personas asociadas al producto incluidas a t tulo enunciativo los ingresos y ganancias no percibidas ventas anticipadas oportunidades comerciales el buen nombre la interrupci n de la actividad 29 comercial o cualquier otro da o que haya provocado Todas las garant as excepto la garant a limitada incluida en el presente por medio de la presente quedan expresamente anuladas y excluidas Algunos estados no permiten la exclusi n ni la limitaci n de los da os accidentales ni directos o el plazo
27. el alargador posean el mismo n mero tama o y forma que aquellos presentes en el enchufe del Instant Power e El alargador se encuentre correctamente conectado y en buenas condiciones el ctricas e Que el cable de la extensi n sea de calibre 18 AWG o m s potente si es de 50 pies de largo o menos Para reducir el riesgo de descarga el ctrica apaga y o desenchufe el Instant Power antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo No utilice el Instant Power si el mismo recibi un golpe fuerte si se cay o si sufri da os de cualquier otra forma h galo revisar por una persona capacitada que efect e reparaciones Comun quese al 1 800 621 5485 de Servicios al cliente No desarme el Instant Power h galo revisar por una persona capacitada que efect e reparaciones cuando necesite servicio de mantenimiento o una reparaci n Volver a ensamblar el Instant Power en forma incorrecta puede provocar riesgo de incendio o descarga el ctrica Comun quese al 1 800 621 5485 de Servicios al cliente AA ADVERTENCIA RIESGO DE GASES EXPLOSIVOS 1 10 RESULTA PELIGROSO TRABAJAR EN FORMA CERCANA A UNA BATER A DE PLOMO LAS BATER AS GENERAN GASES EXPLOSIVOS DURANTE SU NORMAL FUNCIONAMIENTO POR ESTE MOTIVO RESULTA DE SUMA IMPORTANCIA QUE SIGA LAS INSTRUCCIONES CADA VEZ QUE UTILIZA EL INSTANT POWER Para reducir el ri
28. es nose or mouth Determine the voltage of the battery by referring to the vehicle owner s manual and make sure that the output voltage of the jump starter is correct Make sure that the Instant Power cable clips make tight connections 3 3 FOLLOW THESE STEPS WHEN CONNECTING TO A BATTERY AWARNING WARNING AWARNING A SPARK NEAR THE BATTERY AWARNING AWARNING AWARNING Se ee AER EXPLOSION TO REDUCE THE H RISK OF A SPARK NEAR THE a BATTERY 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 4 Attach the output cables to the battery and chassis as indicated below Never allow the output clips to touch each other Position the DC cables to reduce the risk of damage by the hood door and moving or hot engine parts NOTE If it is necessary to close the hood during the jumping process ensure that the hood does not touch the metal part of the battery clips or cut the insulation of the cables Stay clear of fan blades belts pulleys and other parts that can cause injury Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter then the NEGATIVE NEG N post Determine which post of the battery is grounded connected to the chassis If the negative post is grounded to the chassis as in most vehicles see step 3 6 If the positive post is grounded to the chassis see step 3 7 For a negative grounded vehicle connect the POSITIVE RED clip from the I
29. esgo de explosi n de una bater a siga estas instrucciones y aquellas publicadas por el fabricante de la bater a y por el fabricante de cualquier equipo que intente utilizar en la proximidad de la bater a Revise las pautas de precauci n en estos productos y en el motor 18 2 PRECAUCIONES PERSONALES AL ADVERTENCIA 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 RIESGO DE GASES EXPLOSIVOS UNA CHISPA CERCA DE LA BATER A HACER QUE LA BATER A EXPLOTE PARA REDUCIR EL RIESGO DE CHISPAS CERCA DE LA BATER A Resulta peligroso trabajar en forma cercana a una bater a de plomo Las bater as generan gases explosivos durante su normal funcionamiento Por este motivo resulta de suma importancia que siga las instrucciones cada vez que utiliza el Instant Power NUNCA fume o permita la presencia de chispas o llamas en la proximidad de una bater a o motor No deje que la bater a interna se congele Nunca cargue una bater a congelada Para prevenir cortos NUNCA permita que las pinzas se junten o hagan contacto por medio de un mismo metal La carga de la bater a interna del Instant Power debe realizarse en areas bien ventiladas sin restricci n alguna Tenga especial cuidado para reducir el riesgo de dejar caer una herramienta de metal sobre una bater a Esto podr a provocar chispas o un cortocircuito en la bater a o en cualquier otra pieza el ctrica que podr a provocar una explosi n No utilice ele
30. fe interno del cargador de bateria no mostrado Pinzas de bateria interruptor ENCENDIDO APAGADO y USB Puerto USB Pinzas de la bateria e21 o 7 1 7 2 XP750C 1 Indicadores del estado de la bater a 2 Interruptor del estado de la bater a 3 Salida de energia de CC de 12V 4 Enchufe interno del cargador de bater a no mostrado 5 Pinzas de bater a interruptor ENCENDIDO APAGADO y USB 6 Puerto USB 7 L mpara integrada 8 Con interruptor de APAGADO ENCENDIDO para l mpara 9 Con interruptor de APAGADO ENCENDID para el compresor de aire no mostrado 10 V lvula del compresor de aire no mostrada 11 Manguera del compresor de aire 12 Sujetador para la manguera del compresor de aire no mostrado 13 Adaptadores del compresor de aire y estuche para guardar no mostrado 14 Pinzas de la bater a PARA CARGAR LA BATERIA INTERNA DE LA FUENTE DEL INSTANT POWERm IMPORTANTE CARGUE LA UNIDAD INMEDIATAMENTE DESPUES DE COMPRARLA DESPUES DE CADA USO Y CADA 30 DIAS PARA ASI MANTENER LA FUENTE DE PODER PORTATIL CARGADA COMPLETAMENTE Indicador LED PARA VERIFICAR EL ESTADO DE CARGA INTERNA DE LA BATER A OPRIMA EL BOT N DE ESTADO DE LA BATER A INTERNA EN LA DELANTERA DEL INSTANT POWER Las luces LED indicar n el nivel de carga flotante de la siguiente manera e Una luz roja indica una carga del 50 o menos y que se debe recargar inmediatamente e Una luz amarilla indica una carga e
31. follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of the battery Review the cautionary markings on these products and on the engine 2 PERSONAL PRECAUTIONS AWARNING AWARNING AWARNING RISK OF EXPLOSIVE GASES A AWARNING AWARNING AWARNING eo ME aie cay aa CAUSE A BATTERY EXPLOSION TO REDUCE THE RISK OF A e SPARK NEAR THE BATTERY 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 Working in the vicinity of a lead acid battery is dangerous Batteries generate explosive gases during normal battery operation For this reason it is of utmost importance that you follow the instructions each time you use the Instant Power NEVER smoke or allow a spark or flame in the vicinity of a battery or engine Do not permit the internal battery of the Instant Power to freeze Never charge a frozen battery To prevent sparking NEVER allow clips to touch together or contact the same piece of metal When charging the internal battery of the Instant Power work in a well ventilated area and do not restrict the ventilation in any way Be extra cautious to reduce the risk of dropping a metal tool onto a battery It might spark or short circuit the battery or other electrical part that may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery
32. he clara de huevo o agua NO provoque v mito Busque ayuda m dica de inmediato Mant ngase alejado de las paletas del ventilador correas poleas y otras piezas que podr an provocar lesiones 19 2 15 2 16 2 17 3 Limpie los terminales de la bater a antes de usar el Instant Power Durante la limpieza evite que la corrosi n producida por aire tenga contacto con sus ojos nariz y boca Utilice bicarbonato de sodio y agua para neutralizar el cido de la bater a y ayudar a eliminar la corrosi n producida por aire No toque ojos nariz o boca Determine el voltaje de la bater a consultando el manual del usuario del veh culo y aseg rese de que la tensi n de salida del voltaje el aparato sea la correcta Aseg rese de que las pinzas del Instant Power se encuentren firmemente conectadas SIGA ESTOS PASOS CUANDO SE CONECTE A LA BATER A AAADVERTENCIA AAADVERTENCIA ADVERTENCIA UNA CHISPA PROVOCADA CERCA 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 DE LA BATERIA PUEDE CAUSAR LA EXPLOSION DE LA BATERIA PARA REDUCIR EL RIESGO DE PROVOCAR CHISPAS CERCA DE LA BATERIA Conecte los cables de salida a la bateria y al chasis segun lo indicado abajo Nunca permita que las pinzas hagan contacto una con el otra Ubique los cables de C C para reducir el riesgo de da os a la cubierta a la puerta y a las piezas m viles o calientes del motor NOTA Si es necesario cerrar el cofre durante el pro
33. lado tirando la palanca hacia abajo 4 Accione la palanca del interruptor del compresor a la posici n de encendido y comience a inflar el producto 5 Una vez inflado el producto en la presi n de aire apropiada usando el calibrador de aire accione la palanca del interruptor del compresor a la posici n de apagado y desprenda la manguera 6 Realice intervalos de no m s de 10 minutos a la vez Permita que el Instant Power se enfr e antes de usarla de nuevo NOTA Para prevenir un sobrecalentamiento el compresor tiene una protecci n termal integrada internamente que apaga el compresor antes de sobrecargarse En caso de que el compresor se apague solo espere unos minutos y l mismo reiniciar la operaci n de nuevo despu s de enfriarse NOTA El Compresor de aire esta dise ado para 150 PSI 025 9 1 9 2 9 3 9 4 9 5 10 10 1 10 2 10 3 10 4 10 5 Tiempo estimado para inflar Llantas de veh culo del 13 al 16 6 a 24 minutos Pelotas para deportes 30 segundos Estos lapsos de tiempo son aproximados use el calibrador de para asegurase de que la presi n del aire recomendada ha sido alcanzada No sobre infle INSTRUCCIONES DE MANTENIMIENTO Despu s de usar y antes de realizar mantenimiento desenchufe y desconecte el Instant Power ver secciones 3 y 4 Utilice un pa o seco para limpiar la corrosi n de toda la bater a y otra suciedad o aceite de los terminales cables y car
34. mentos personales de metal tales como anillos pulseras collares y relojes al trabajar con una bater a de plomo cido Una bater a de plomo cido puede producir una corriente de cortocircuito lo suficientemente elevada como para soldar un anillo o provocar efectos similares sobre el metal causando una quemadura de gravedad Aseg rese de que el rea que rodea a la bater a se encuentre bien ventilada mientras el aparato se utiliza ADVERTENCIA 2 9 2 10 2 11 2 12 2 13 2 14 RIESGO DE CONTACTO CON EL CIDO DE LA BATER A EL CIDO DE LA BATER A ES UN CIDO SULF RICO ALTAMENTE CORROSIVO Considere la idea de que alguna persona se encuentre cerca suyo para poder ayudarlo cuando trabaje en forma cercana a una bater a de plomo cido Cuente con una gran cantidad de agua potable y jab n a mano en caso de que el cido de la bater a tenga contacto con su piel ropa u ojos Utilice protecci n visual y corporal completa incluyendo gafas de seguridad y prendas de protecci n Evite tocar sus ojos mientras trabaje en forma cercana a la bater a Si el cido de la bater a tiene contacto con su piel o su ropa lave de inmediato el rea afectada con agua y jab n En caso de que ingrese cido en un ojo sumerja el mismo de inmediato bajo agua potable corriente por al menos 10 minutos y obtenga atenci n m dica en forma inmediata Si el cido de la bater a es accidentalmente ingerido se recomienda beber lec
35. nstant Power to the POSITIVE POS P ungrounded post of the battery Connect the NEGATIVE BLACK clip to the vehicle chassis or engine block away from the battery Do not connect the clip to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block For a positive grounded vehicle connect the NEGATIVE BLACK clip from the Instant Power to the NEGATIVE NEG N ungrounded post of the battery Connect the POSITIVE RED clip to the vehicle chassis or engine block away from the battery Do not connect the clip to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block When disconnecting the Instant Power turn all switches to off if applicable remove the clip from the vehicle chassis and then remove the clip from the battery terminal GROUNDING AND AC POWER CORD CONNECTIONS 4 1 RISK OF ELECTRIC SHOCK OR FIRE The Instant Power internal charger plug is for use on a nominal 120 volt circuit The extension cord utilized with the internal charger plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet Do not use with an ungrounded system ASSEMBLY INSTRUCTIONS Remove all cord wraps and uncoil the cables prior to using the Instant Power 6 FEATURES XP400
36. nte de Verifique la condici n de poder no est cargada carga de la bater a girando el interruptor situado enfrente de la fuente de poder Consulte la secci n de Indicadores LED en este manual El aparato de 12V absorbe Desconecte el aparato de m s de 15A o tiene un 12V El interruptor interno corto circuito se autoprogramar despu s de uno o dos minutes Si sucede lo mismo reemplace el aparato de 12V La bater a de La Fuente de La bater a est en malas Haga un chequeo de la poder no retiene la carga condiciones No recibir bater a carga Si las soluciones descriptas no eliminan el problema o por informaci n sobre la soluci n de problemas o repuestos puede llamar a la l nea gratuita desde cualquier lugar de los EE UU 1 800 621 5485 7 00 a m a 5 00 p m hora central de lunes a viernes e 2 70 12 ESPECIFICACIONES Modelo XP400 Tipo Interno de la Bater a a er de mantenimiento AGM de Carga M xima Cont nua Amperaje de Arranque en fr o coa de Conexi n de Bater a con calibre 8 AWG 18 45 72 cm de Largo Dimensiones AxA x P 10 x 10 25 x 5 25 25 4 cm x 26 cm x 13 3 cm 7 lbs 3 18 kg Modelo XP500 Tipo Interno de la Bater a ici ee de mantenimiento AGM de Carga M xima Cont nua Semi de Conexi n de Bater a con calibre 8 AWG 18 45 72 cm de Largo Dimensiones A x A x P 10 x 10 25 x 5 25 25 4 cm x 26 cm x 13 3 cm 82 Ibs 3749 Peso 28 Mo
37. ntre el 50 y el 75 Se puede usar el Instant Power pero debe recargarse lo m s pronto posible e La luz verde indica que la bater a interna est totalmente cargada Cargando la bater a interna con el Cargador Interno Adaptado 1 Para cargar volt e el enchufe del cargador localizado en la parte posterior al del Instant Power y conecte una extension de calibre 18 AWG El cord n de extensi n no viene con la unidad se necesita comprar por separado 2 Enchufe el cord n de extensi n en un tomacorriente de 120V CA 3 La luz LED ROJA brilla para indicar CARGANDO 22o 4 La luz LED VERDE se encender cuando la bater a haya alcanzado su carga total Esto puede llegar a tomar hasta 72 horas dependiendo de los a os de uso edad y condici n de la bater a El cargador cambiar autom ticamente a la funci n de modo de mantenimiento y mantendr la bater a cargada totalmente sin danarla 5 Cargue el Instant Power tan pronto sea posible despu s de usarse IMPORTANTE No utilice el Instant Power La Fuente de Poder mientras carga la bater a interna Tambi n puede cargar la bater a interna mientras maneja usando el cable del cargador macho macho 94500109 no incluida Inserte un extremo del cable en el tomacorriente de 12V CD y el otro extremo en el encendedor del veh culo enchufe del encendedor de cigarros Desconecte completamente el cable del cargador cuando el motor no est funcionando IMPORTAN
38. o not leave the air compressor unattended during use NOTE Before you use the compressor for the first time you must install the compressor hose wrap cleats To install Press each cleat into its corresponding mounting holes on the back of the jump starter until it clicks into place Wrap the compressor hose around these cleats when it is not being used 1 Ensure the battery clips are securely on the storage holders 2 Remove the air compressor hose from the storage cleats on the back of the Instant Power Install adapters as necessary 3 Attach the air compressor hose to the product or accessory to be inflated by flipping down the lever 4 Toggle the Compressor Switch up to the ON position and inflate the product 5 When the product is inflated to the proper air pressure using the air compressor gauge toggle the Compressor Switch down to the OFF position and remove the hose 6 Do not run for more than 10 minutes maximum at a time Allow the Instant Power to cool down for 10 minutes before using again NOTE To prevent overheating the compressor has built in thermal protection that will turn the compressor off before it overheats If the compressor shuts off wait a few minutes and it will automatically restart when the compressor cools NOTE The air compressor is rated for 150 PSI Estimated Time for Inflating Vehicle Tires 13 to 16 6 to 24 minutes These times are approximate use the air compresso
39. r gauge to ensure the proper pressure has been reached Do not over inflate 9 MAINTENANCE INSTRUCTIONS 9 1 After use and before performing maintenance unplug and disconnect the Instant Power see sections 3 and 4 9 2 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips cords and the Instant Power case 9 3 Ensure that all of the Instant Power components are in place and in good working condition for example the plastic boots on the battery clips 9 4 Servicing does not require opening the unit as there are no user serviceable parts 9 5 All other servicing should be performed by qualified service personal o 10 MOVING AND STORAGE INSTRUCTIONS 10 1 Store the Instant Power in an upright position 10 2 Store inside in a cool dry place 10 3 Do not store the clips on the handle clipped together on or around metal or clipped to cables The clips on the Instant Power are live and will produce arcing or sparking if they come in contact with each other To prevent accidental arcing always keep the clips on the storage holders when not using it to jump start a vehicle 10 4 Ifthe Instant Power is moved around the shop or transported to another location take care to avoid prevent damage to the cords clips and Instant Power Failure to do so could result in personal injury or property damage IMPORTANT Do not use and or store the Instant Power in or on any
40. rdous situation which if not avoided could result in death or serious injury to the operator or bystanders AWARNING Indicates a potentially hazardous situation which if not avoided could result in moderate or minor injury to the operator or bystanders ACAUTION Indicates a potentially hazardous situation which if not avoided could result in damage to the equipment or vehicle or property damage MPORTANT gt gt Z Q m J Safety messages in this manual contain two different type styles e Unnumbered type states the hazard e Numbered type states how to avoid the hazard The icon gives a graphical description of the potential hazard A b d Pursuant to California Proposition 65 this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm e 1 Le IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions RISK OF ELECTRIC SHOCK OR FIRE 1 1 Read the entire manual before using this product Failure to do so could result in serious injury or death 1 2 Keep out of reach of children 1 3 Use only recommended attachments Use of an attachment not recommended or sold by Schumacher Electric Corporation may result in a risk of fire electric shock or injury to persons or damage to property 1 4 Do not put fingers or hands into any of the Instant Power s outle
41. ts 1 5 Do not expose the Instant Power to rain or snow 1 6 Use of an improper extension cord to charge the Instant Power could result in a risk of fire and electric shock Make sure e That the pins on the plug of the extension cord are the same number size and shape as those of the plug on the Instant Power e That the extension cord is properly wired and in good electrical condition e That the extension cord has a wire size of 18 gauge AWG or larger and is 50 feet long or less 1 7 To reduce the risk of electric shock turn off and or unplug the Instant Power before attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk 1 8 Do not operate the Instant Power if it has received a sharp blow been dropped or otherwise damaged in any way take it to a qualified service person Call customer service at 1 800 621 5485 1 9 Do not disassemble the Instant Power take it to a qualified service person when service or repair is required Incorrect reassembly may result in a risk of fire or electric shock Call customer service at 1 800 621 5485 RISK OF EXPLOSIVE GASES 1 10 WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE INSTANT POWER 1 11 To reduce the risk of a battery explosion