Home
Model: - Husky Power Washer, Home Depot Pressure Washer
Contents
1. PARTS LIST Fig 1 Gun and Hose Assembly Variable Nozzle with Lance GFCI Water Inlet Filter Screen Quick Connect Assembly High Pressure Hose Threaded Nut Coupler Safety Lock Motor and Pump in Case Power Supply Cord 10 ON OFF Switch 1 1 Soap Lance Assembly 12 High Pressure Outlet 13 Shipping Plug Q0 NOU Rh ON LISTA PIEZAS Fig 1 Tubo de alta presi n y Grupo Pistola Lanzador con Boquilla Chorro Regulable Enchufe el ctrico con Interruptor diferencia autom tico de seguridad Filtro Criba Grupo conexi n r pida manguera flexible jard n Conexi n tuerca rosca manguera de alta presi n Bloqueo de seguridad Cuerpo motor y bomba Cable alimentaci n el ctrica 10 Interruptor ON OFF 11 Grupo de lanzamiento espuma 12 Toma alta presi n 13 Tap n para el agua DONQUBb WN HD1400 POWERWASHER WATER CONNECTION CONEXI N DEL AGUA C i comm Inlet S Filt N nlet Screen Filter Filtro criba E CE Inlet Nipple Entrerrosca 7 77 2 7 GA lt D gt A 2 S Manguera flexible jardin Machine Inlet Agujero admisi n m quina i Quick Connector Conexi n r pida Fig 2 ATTENTION Proper water connection A 2 0 SAFETY FEATURES The pressure washer is equipped with a stop device which will sense when the trigger on the gun is released It will open the power circuit to the motor and cause the
2. A Bloqueo de seguridad cerrado B Bloqueo de seguridad abierto Move the power on off switch on the pressure washer to the ON position Squeeze the gun trigger and the pressure washer motor will start WARNING make sure the wand is AN pointed in a sate direction when starting the pressure washer Do not point at face WARNING feel as serious injury could result NOTE Make sure wand is locked see the picture in the next page 7 Cologuen el interruptor ON OFF de la hidrolimpiadora en ON 8 Aprieten el gatillo de la pistola ahora el motor de la hidrolimpiadora se pondr en marcha IMPORTANTE cuando se hace arrancar la hidrolimpiadora verifiquen que AN el lanzador est dirigido hacia una A direcci n no peligrosa No dirigirlo hacia ATENCION rostro los pies para evitar posibles da os NOTA Aseg rense de que el bloqueo de seguridad est cerrado ver la figura de la p gina siguiente POWERWASHER HD1400 Fig 5 4 2 VARIO SPRAY NOZZLE The adjustable spray nozzle can adjust spray from fan to pencil point The spray is adjusted by turning the nozzle Fig 6 A CAUTION CAUTION the pencil point spray adjustment is very aggressive We recommend that for most cleaning applications a twenty degree 20 spray angle be used to avoid damage to the surtace being sprayed NOTE the pressure of the spray on the surface you are
3. 7 0 MANIPULACI N Y ALMACENAMIENTO ATENCI N almacenen la hidrolimpiadora en un local cuya temperatura no descienda AN por debajo de los 32 F En el caso de congelamiento la bomba de este equipo est ATENCI N sujeta a da o permanente LOS DANOS PROVOCADOS POR EL HIELO NO ESTAN CUBIERTOS POR LA GARANTIA Si almacenan la hidrolimpiadora en un local donde la temperatura es inferior a los 32 F pueden disminuir el riesgo de da o del equipo siguiendo el siguiente dale 1 Detengan la hidrolimpiadora y desconecten la manguera de alimentaci n y la de alta presi n Presionen el gatillo de la pistola de descarga para hacer salir toda el agua del lanzador y de la manguera Pongan nuevamente en marcha la hidrolimpiadora y d jenla en funcionamiento durante un breve per odo unos 5 segundos hasta que saldr el agua por la salida de la alta presi n POWERWASHER 8 0 TROUBLESHOOTING HD1400 PROBLEM POSSIBLE CAUSE CORRECTION Motor will not start or stops while operating Loose or disconnected plug Tripped pressure washer thermal switch Power Blast trigger not operating properly Reconnect plug Allow to cool and restart unit Call customer Service Department Circuit breaker trips or fuse blown in fuse box Circuit Overload Extension cord too long or wire size too small Nozzle partially blocked Excessive pressure Check that the circuit is rated 15 amps or Disconn
4. a no ser aplicable en el caso de prohibici n por parte de un Estado o de una administraci n comunal federal y no pueda ser substituida La presente garant a les Siis derechos especificos y Uds pueden tener tambien otros derechos gue varian de un Estado a ofro POWERWASHER 2455 PACES FERRY RD N W ATLANTA GEORGIA 30339 4024 1 888 550 1606 Sitio Internet www hdpowerwasher com Registro de garant a mediante Internet d e 02 2004 cod PLDC90761 REV 1
5. de baja presi n NOTA SI EL EXCESO DE CERA NO ES EXTRAIDO SE PUEDE OBTENER UN RESULTADO OPACO 4 Efect en el secado para reducir las manchas de agua 4 5 FINALIZACI N DE LA OPERACION Cuando han completado la aplicaci n del jab n cera extraigan el frasco y hagan pasar agua limpia por la manguera hasta que se limpie mena NOTA la falto de una limpieza a fondo puede provo car una obturaci n en el sistema de inyecci n y ser inutilizable 1 Detengan el equipo presionando el bot n on off 1 Desconeclen la toma el ctrica 1 el agua y depresuricen el equipo presionando el gatillo ATENCI N cierren la alimentaci n del N agua y presionen el gatillo para depresurizar el equipo La falta de depresurizaci n puede ATENCI N provocar da os a las personas debido a la descarga del agua de alta presi n Desconecten la manguera de descarga de la alta presi n y la manguera de introducci n del agua 5 0 MANUTENCI N 5 1 CONEXIONES Las conexiones a mangueras la pistola y el lanzador de chorro de la Bd lodo ora deben ser limpiados regularmente y lubricados con grasa para prevenir las p rdidas y la rotura de los o rings 5 2 BOQUILLA El dispositivo de regulaci n de la boquilla debe ser lubricado con regularidad La obturaci n delo boquilla provoca el aumento de la presi n de la bomba y con toda probabilidad la distorsi n de la forma del chorro Se requiere una limpieza inmediata ver
6. n el ctrica protegida por un interruptor de protecci n de las descargas interruptor diferencial autom tico de seguridad 3 No toquen el enchufe o la toma con las manos mojadas 4 Eviten encendidos accidentales Coloquen el interruptor en OFF antes de conectar o desconectar el cable el ctrico a una toma 5 No dirijan nunca el chorro del agua sobre instalaciones el ctricas o sobre j misma hidrolimpiadora de alta presi n con el fin de evi tar sacudidas el ctricas 6 No utilicen el cable para mover la hidrolimpiadora de alta presi n No tirar del cable para desconectar el equipo de la toma 7 Con el fin de evitar da os el cable no debe ser aplastado no debe ser colocado cerca de objetos cortantes ni de fuentes de calor cuando el equipo es utilizado hay seguir precauciones basilares entre las cuales HD1400 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 LO 24 25 26 27 28 29 30 Stay alert watch what you are doing Follow maintenance instructions specified in this manual Check power cords before using Damaged cords can reduce pa of pressure washer or cause a fatal electric shock Keep operating area clear of all persons To reduce the risk of injury close supervision is necessary when this product is used near children Always use both hands when operating pressure washer to maintain complete control of the
7. de amperaje 15 Amp Preesi n del agua de introducci n de 20 a 100 psi Agua de introducci n Agua fr a de grifo ngulo del chorro boquilla 0 60 Porcentaje inyecci n jab n del 2 al 4 Flujo de agua y tasa de massima presi n determinado de acuerdo y PWMA Standard PW101 Ll menos inmediatamente Si faltan piezas o hay piezas da adas NO MANDEN SU EQUIPO AL ALMACEN Nuestra Oficina Asistencia Clientes est siempre disponible para ayudarles para resolver cualquier problema o para preguntas operativas Nuestro numero gratuito interurbano es 1 888 550 1606 HD1400 Limited Warranty This product is warranted by us to the original retail consumer against defects in material and workmanship for a period of one year on the machine 90 days on the gun hose as well as 90 days on the ground fault circuit interrupter GFCI effective from the date of retail purchase and is not trasferable This warranty applies only to products used in consumer applications This warranty does not apply to commercial or rental applications Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed Register by Internet at www hdpowerwasher com Return of this card is not reguired to validate this warranty WHAT IS COVERED Replacement parts and labor WHAT IS NOT COVERED This warranty does not include such parts as nozzles whic
8. la figura de la p gina siguiente Separar la boquilla del lanzador Fig 8 Limpien la boquilla Laven abundantemente con agua hacia la parte trasera de la boquilla Conectar nuevamente la boquilla al lanzador 1 A WN gt POWERWASHER NOTE complitely screw the nozzles on the wand up to the complete lock see picture Fig 8 Restart the pressure washer and depress the trigger on the spray gun Ifthe nozzle is still plugged repeat above items 1 through 4 HD1400 NOTA atornillar completamente las boquillas en el lanzador hasta cerrar completamente ver dibujo Fig 8 Hacer arrancar nuevamente la hidrolimpiadora y bajar el gatillo de la pistola de chorro Si la est a n bloqueada o parcialmente bloqueada repitan dichas operaciones desde el punto 1 hasta el punto 4 Fig 8 5 3 LUBRICATION The pressure washer is designed with a permanent lubrication system Conventional oil check and oil changes are not necessary NOTE IN CASE OF OIL LEAKAGE CONTACT THE FAIP NORTH AMERICA CUSTOMER SERVICE DEPARTMENT CONCERNING REPAIR A SMALL AMOUNT OF OIL LEAKAGE IS NORMAL 5 4 WATER SCREEN The pressure washer is equipped with a water inlet screen to protect the pump CAUTION f the screen is not kept clean the flow of water to the pressure washer CAUTION Will be restricted and the pump may be damaged 1 To clean inner conical water screen remove quick connect and remove the plastic
9. page 12 3 2 WATER CONNECTION page 12 3 3 POWER SUPPLY CONNECTION page 12 4 0 OPERATING INSTRUCTIONS page 13 4 1 START UP PROCEDURE page 14 4 2 VARIO SPRAY NOZZLE page 15 4 3 USE OF CHEMICAL page 16 4 4 CLEANING TECHNIQUES page 16 4 5 END OF OPERATION page 17 5 0 page 17 5 1 CONNECTIONS page 17 page 17 5 3 LUBRICATION page 18 5 4 WATER SCREEN page 18 5 5 COOLNG SYSTEM page 18 6 0 SERVICING A DOUBLE INSULATED APPLIANCE page 19 7 0 MOVING AND STORAGE INSTRUCTIONS page 19 8 0 TROUBLESHOOTING page 20 9 0 TECHNICAL DATA page 22 INDICE 1 0 NORMAS OPERATIVAS Y DE SEGURIDAD nataci n pag 2 0 CARACTER STICAS RELATIVAS A LA SEGURIDAD pag 3 0 CONEXIONES OPERATIVAS pag 3 1 MANGUERA DE ALTA pag 3 2 CONEXI N DEL AGUA pag 3 3 EMPALME DE LA ALIMENTACI N EL CTRICA pag 4 0 INSTRUCCIONES DE USO pag 4 1 PROCEDIMIENTO DE PUESTA EN MARCHA pag 4 2 BOQUILLA CHORRO REQULABLE eterna pag 4 3 USO DE PRODUCTOS OUIMICOS 0 pag 4 4 T CNICAS DE LIMPIEZA pag
10. ser n mezclados autom ticamente con el agua y descargados a trav s de la boquilla EN Fig 7 4 4 CLEANING TECHNIQUES When cleaning with the Pressure Washer may cleaning tasks can be solved with water alone but for most tasks it is advantageous to use a detergent also A detergent ensures a quick soaking of the dirt allowing the high pressure water to penetrate and remove the dirt more effectively The low pressure provides a gentle application of soap and or wax Low pressure is also recommended to rinse a surface after wax application or for other applications which require the low pressure of a garden hose Low pressure is the equivalent of a garden hose set at the lowest output to properly apply soap and wax FOR SOAP WAX APPLICATION ATTACH SOAP DISPENSER ASSEMBLY APPLICATION OF SOAP DEGREASER 1 Apply the Pressure Washer Soap solution to a DRY work surface NOTE WETTING THE SURFACE FIRST IS NOT RECOMMENDED AS IT DILUTES THE DETERGENT AND REDUCES ITS CLEANING ABILITY On a vertical surface apply soap horizontally from side to side starting from the bottom to avoid streaking N CAUTION avoid working on hot surfaces or in direct sunlight to minimize WARNING the chance of the soap damaging painted surfaces 2 Allowthe soap to remain on the surface for a short time before rinsing 16 4 4 T CNICAS DE LIMPIEZA Cuando se procede a la limpieza con la hidrolimpiadora se pueden efectua
11. store your pressure washer in a location where the temperature will not fall below 32 F The pump in this machine is susceptible to permanent damage CAUTION if frozen FREEZE DAMAGE 15 NOT COVERED BY THE WARRANTY IF you must store your pressure washer in a location where the temperature is below 32 F you can minimize the chance of damage to your machine by utilizing the following procedure 1 Stop the pressure washer and detach supply hose and high pressure hose Squeeze le trigger of the discharge gun to drain all water from the wand and hose Restart the pressure washer and let it run briefly about 5 seconds until water no longer discharges from the high pressure outlet POWERWASHER 6 0 MANUTENCI N DE UN EQUIPO CON DOBLE AISLAMIENTO Un equipo con doble aislamiento est dotado de dos sistemas de aislamiento en lugar de la puesta a tierra No es montada ninguna puesta a tierra sobre un art culo de doble aislamiento ni puede ser a adida a la hidrolimpiadora La manutenci n de este tipo de instalaci n requiere sumo cuidado un buen conocimiento del sistema y debe ser efectuada sola mente por personal cualificado Las piezas de repuesto de una instalaci n de doble aislamiento deben ser id nticas a las piezas que hay que cambiar Estos equipos est n identificados por las palabras DOBLE AISLAMIENTO DOUBLE INSULATION o DOUBLE INSULATED El puede estar identificado tambien con el siguiente simbolo
12. wand Do nottouch nozzle or water spray while operating Wear safety goggles while operating Disconnect power plug from the outlet when not in use and prior to the detaching of the high pressure hose Only pressure Washer hoses and nozzles should e used Never tie knots or kink the high pressure hose as damage could result Prior to starting the pressure washer in cold weather be sure ice has not formed in any part of the equipment Carefully observe all chemical instructions and warnings before using The pressure washer should not be used in areas where gas vapors may be present An electric spark could cause an explosion or fire To minimize the amount of water getting into the pressure washer the unit should be placed as far as possible from the cleaning site during operation To prevent accidental discharge the spray gun should be secured by locking trigger when not in Do not operate this product when fatigued or under the influence of alcohol or drugs To allow free air circulation the pressure washer should NOT be covered during operation Know how to stop the product and bleed pressure guickly Be thoroughly familiar with the controls Do not over reach or stand on unstable support Keep good footing and balance at all times WARNING Risk of injection or injury Do not direct discharge stream at persons See OPERATING CONNECTIONS Page 12 for information on Extension Cords
13. 4 5 FINALIZACI N DE LA OPERACION pag 5 0 MANUTENCI N pag 2 1 CONEXIONES comarcas pag 5 2 BOQUILLA pag 5 3 LUBRICACJ N pag 5 4 FILTRO DE pag 5 5 SISTEMA DE REFRIGERACI N pag 6 0 MANUTENCI N DE UN EQUIPO CON DOBLE AISLAMIENTO pag 7 0 MANIPULACI N Y ALMACENAMIENTO pag 8 0 LOCALIZACI N DE LAS AVER AS iiir pag 9 0 DATOS TECNICOS pag POWERWASHER 16 16 17 17 17 17 18 18 18 21 22 HD1400 POWERWASHER 1 0 SAFETY AND OPERATION 1 0 NORMAS OPERATIVAS Y DE RULES SEGURIDAD Safety precautions are essential when any mechanical eguipment is involved These precautions are necessary when using storing and servicing mechanical eguipment Using this eguipment with the respect and caution demanded will considerably lessen the possibilities of personal injury If safety precautions are overlooked or ignored per sonal injury or property damage may occur The following symbols shown below are used extensively ut this manual Always heed these precautions as they are essential when using any mechanical eguipment this warning symbol identifies specific instructions or procedures which if no WARNING correctly followed could result in perso nal injury or death CAUTION this caution symbol identifies specific instr
14. E para reducir la posibilidad de electrocuci n mantengan la extensi n seca y fuera de tierra No toquen el enchufe con las manos mojadas A Controlen el cable antes del uso Si est da ado no lo utilicen B Mantengan secas y fuera de tierra todas ATENCI N las conexiones C No toquen el enchufe con las manos mojadas PROTECCI N CON INTERRUPTOR DIFERENCIAL AUTOMATICO DE SEGURIDAD A Conecten s lo a una toma con una toma de tierra id nea No extraigan el enchufe de tierra La hidrolimpiadora es suministrada con un interruptor diferencial autom tico de seguridad instalado en el enchufe de alimentaci n Si es necesario substituir el enchufe o la toma usen s lo piezas de repuesto del mismo tipo Para una substituci n correcta contacten la Oficina de Asistencia Clientes 4 0 INSTRUCCIONES DE USO IMPORTANTE riesgo de impregnaci n o de da os NO ATENCI N descarguen el flujo sobre las personas ATENCI N ATENCI N lean el manual antes del uso Antes de poner el equipo en marcha por primera vez y despu s de un largo per odo de almacenamiento controlar que el motor gire libremente Despu s de haber efectuado esta operaci n sigan las instrucciones de las secciones 3 0 Conexiones operativas y 4 0 Instrucciones de uso POWERWASHER 4 1 START UP PROCEDURE 1 Make sure water supply is connected and turned on Make sure the unit is plugged in Release gun safety if locked Fig 4 To allow
15. POWERWASHER Operator s Manual Manual del Usuario Model HD1400 1400 PSI Warranty Registration by Internet Registro Garantia mediante Internet Internet Address www hdpowerwasher com Sitio Internet www hdpowerwasher com SEE OUR WEB SITE FOR REPLACEMENT MISSING PARTS AND TROUBLESHOOTING VISITEN NUESTRO SITIO WEB PARA SUSTITUCIONES Y O PARTES FALTANTES HELP LINE 1 888 550 1606 READ AND SAVE THESE INSTRUCTIONS LEER Y CONSERVAR ESTA INSTRUCCIONES POWERWASHER HD1400 HUSKYPOWERWASHER Your Model Number is HD1400 1400 PSI IMPORTANT Record your Serial Number below Attention Valued Customer Warranty Claims and the ordering of Replacement Parts the information you provide below is important and necessary Register your new HDPOWERWASHER at the www hdpowerwasher com web site For ease of reference please record now the serial number and the date of purchase in the space provided below m Number 1 1 1 1 1 eee l m of Purchase 200 HD1400 POWERWASHER HUSKYPOWERWASHER EI N mero de su Modelo es HD1400 1400 PSI IMPORTANTE Registre a continuaci n el N mero de Serie Atenci n Estimado cliente para efectos de la Garant a y la solicitud de Piezas de Repuesto es importante y necesaria la informaci n que nos proporcione a continuaci n Registre su nueva HDPOWERWASHER en el sitio Internet www hdpowerwasher com Para consultas m s f ciles regi
16. See SERVICING OF A DOUBLE INSULATED PRODUCT Section 6 0 SAVE THESE INSTRUCTIONS 8 9 10 11 12 15 16 20 21 22 29 24 25 26 27 28 29 30 POWERWASHER Est n atentos y miren bien lo que se est n haciendo Para la manutenci n sigan las instrucciones presentadas en el presente manual Antes del uso controlen los cables el ctricos Los cables da ados no s lo reducen las prestaciones de la hidrolimpiadora de alta presi n sino que pueden provocar sacudidas el ctricas Alejen a las personas del rea de trabajo Para reducir los riesgos de da os es absolutamente necesario efectuar un control atento cuando el producto es utilizado cerca de los ni os Usen siempre ambas manos cuando se utiliza la hidrolimpiadora de alta presi n con el fin de mante ner un completo control del lanzador No toquen el lanzador o el chorro de agua cuando est en funcionamiento Durante el uso utilicen gafas de protecci n Desconecten el enchufe el ctrico de la toma cuando no est en uso e igualmente antes de extraer la manguera de alta presi n Hay que utilizar exclusivamente las mangueras y los lanzadores de la hidrolimpiadora de alta presi n No hagan nudos ni plieguen la manguera de alta presi n puesto que podr a da arse En las estaciones fr as antes de poner funcionamiento la hidrolimpiadora controlen que no se haya formad
17. air to escape from the hose squeeze trigger on the un until there is a steady stream of water coming from the nozzle Remove any dirt or foreign matter from the gun outlet and the male connector of the wand Insert the wand into the gun s quick connect coupling by pushing firmly and twisting wand Ya of a turn to lock into place Fig 5 NOTE make sure wand is locked WARNING if the wand is not securely locked into place it could be ejected under WARNING high pressure when operating the gun HD1400 PROCEDIMIENTO DE PUESTA EN MARCHA 4 1 1 Aseg rense de que la alimentaci n del agua est conectada 2 Aseg rense de que el enchufe del equipo est conectado 3 Liberen la seguridad de la pistola si est bloqueada Fig 4 4 Con el fin de permitir la salida de aire de la manguera aprieten el gatillo de la pistola hasta que salga un flujo regular por la boquilla 5 Extraigan la suciedad o los materiales extra os de la salida de la pistola y del conector blando del lanzador 6 Introduzcan el lanzador en la uni n r pida empujando en rgicamente y luego E el lanzador de de vuelta para bloquearlo en su sede Fig 5 NOTA aseg rense que el lanzador est bloqueado IMPORTANTE si el lanzador no est bien bloqueado en su sede cuando se A utiliza la pistola podr a ser expulsada ATENCI N debido a la alta presi n Fig 4 A Safety lock locked B Safety lock unlocked
18. anto dicha limitaci n o exclusi n podr a no ser referida a Uds La presente garant a no cubre los da os resultantes de la falta de io de una de las siguientes condiciones 1 2 La presi n del agua en entrada debe estar entre los 20 y los 100 p s i La temperatura del agua en entrada no debe su perar los 90 F El equipo no debe ser almacenado en zonas donde la temperatura puede llegar por debajo de los 32 F 3 IMPLIED WARRANTIES Any implied warranties including the implied Warranties of Merchantability and fitness for a particular purpose are limited in duration to one year on the machine 90 days on the gun hose as well as 90 days on the ground fault circuit interrupter GFCI effective from the date of retail purchase Some states do not allow limitations on how long an implied warranty lasts therefore the above limitation may not apply to you HOW TO OBTAIN WARRANTY PERFORMAN CE Attach to the product your name address description of the problem phone number and proof of date of retail purchase Sales slip Call our Customer Service Department at 1 888 550 1606 for a return authorization number or unit will be refused Package and return the product transportation charges prepaid to POWERWASHER Attn Warranty Service Dept 560 S Vermont St Palatine IL 60067 To the extent any provision of this warranty is prohibited by federal state or municipal law and cannot be preempted lt sha
19. camente y reactiva las condiciones normales de funcionamiento despu s de un breve per odo HD1400 POWERWASHER GROUND FAULT CIRCUIT INTERRUPTER PROTECTION Fig 3 PROTECCI N CON INTERRUPTOR DIFERENCIAL AUTOMATICO DE SEGURIDAD Fig 3 This pressure washer is provided with a ground fault circuit interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replacement parts that clude GFCI protection La hidrolimpiadora est dotada de un interruptor diferencial autom tico de seguridad GFCI montado en el enchufe del cable de alimentaci n el ctrica Dicho dispositivo suministra una protecci n el contra el riesgo de sacudidas Si fuere necesario substituir el enchufe o el cable utilicen exclusivamente repuestos similares provistos de protecci n CFCI Fig 3 3 0 OPERATING CONNECTIONS 3 1 HIGH PRESSURE HOSE Attach the high pressure hose by carefully inserting the fitting with the pring into the high pressure outlet and tightening the threader nut by hand 3 2 WATER CONNECTION Before connecting run water through the garden hose not supplied to flush out ei foreign matter Attach garden hose to the pressure washer water inlet connection 3 3 POWER SUPPLY CONNECTION The pressure washer is factory equipped with an electrica
20. cleaning increases as you move the wand closer to the surface To increase angle to a fan spray turn counterclockwise 4 2 BOQUILLA CHORRO REGULABLE La boquilla de chorro regulable permite regular el chorro desde el ventilador hasta la punta del l piz El chorro se regula girando la boquilla Fig 6 ATENCI N la regulaci n del chorro de la punta del l piz puede dar resultados agresivos corrosivos Aconsejamos utilizar para la mayor parte de las AN aplicaciones de limpieza un ngulo de ATENCION chorro de veinte grados 20 para no da ar las superficies donde se necesita utilizar el chorro NOTA la presi n del chorro sobre la superficie que est n limpiando aumenta en proporci n al acercamiento del lanzador sobre la superficie misma Para aumentar el ngulo de un chorro de ventilador giren hacia la izquierda Fig To decrease angle to pencil point spray turn clockwise 15 Para disminuir el ngulo del chorro de la punta de l piz giren hacia la derecha POWERWASHER 4 3 USE OF CLEANING CHEMICALS Remove wand Install soap dispenser assembly Fig 7 Remove bottle and check tube The soap or wax will automatically be mixed with the water and discharged through the nozzle poem HD1400 USO DE PRODUCTOS QU MICOS Extraer el lanzador Instalar el lanzador de espuma Fig 7 Extraer la botella y controlar la manguera El jab n o la cera
21. do en el enchufe de alimentaci n HD1400 If replacement of the plug or cord is needed use only identical replacement parts Contact Customer Service for proper replacement parts EXTENSION CORDS Use only extension cords that are intended for outdoor use These extension cords are identified by a marking Acceptable for use with outdoor appliances store indoors while not in use Use only extension cords having an electrical rating not less than the rating of the product Do not use damaged extension cords Examine extension cord before using and replace if damaged Do not abuse extension cord and do not ank on any cord to disconnect Keep cord away from k i and sharp edges Always disconnect the product from the extension cord When using an extension cord observe the specification j Cable Length Wire Gauge Up to 25 ft 12 AWG Outdoor WARNING to reduce the risk of electrocution keep all connections dry and off the ground Do not touch plug with wet hands WARNING A Inspect cord before using Do not use if cord is damaged N B F all connections dry and off the WARNING ground Do not touch with wet hands GROUND FAULT CIRCUIT INTERRUPTER PROTECTION A This product shall only be connected to a power receptacle protected by a ground fault circuit interrupter The pressure washer is provided with a ground fault circuit interrupter built into the power plug If replacement of th
22. e plug or cord is needed use only identical replacement parts Contact Customer Service for proper replacement parts 4 0 OPERATING INSTRUCTIONS WARNING risk of Injection or Injury Do not direct discharge stream at anyone WARNING CAUTION read before operating Before the very first starting and after N extended storage of the machine to verify the motor turns freely After this WARNING operation follow all directions in Section 3 0 Operating Connections and 4 0 Operating Instructions 13 POWERWASHER Si es necesario substituir el enchufe o la toma usen s lo piezas de repuesto del mismo tipo Para una substituci n correcta contacten la Oficina de Asistencia Clientes EXTENSIONES Usen exclusivamente extensiones para uso exterior Dichas extensiones est n marcadas por la frase Aptas ara uso exterior si no las utilizan col quenlas en un sc reparado Usen solamente extensiones con una potencia el ctrica superior a la potencia nominal del equipo No utilicen extensiones da adas Antes del uso controlen la extensi n y si est da ada substit yanla No la usen en modo incorrecto y no tiren del cable para desenchufar Tengan a las extensiones lejos de pem de calor y de ngulos cortantes Desenchufen siempre el equipo de la extensi n Cuando se utilizan extensiones respeten las siguientes caracter sticas Calibres cable 12 AWG Fuera Longitud cable Hasta 25 pies A ATENCI N IMPORTANT
23. ect all loads circuit Use proper extension cord as recommended in Operator s Manual Clean nozzle as instructed in Section Clean nozzle as instructed in Section Water or oil leaking from bottom of pump A small amount of leakage is normal If excessive call Customer Service Department Trigger will not move Gun safety lock engaged Release safety lock Unit will not stop when trigger is released Power Blast Tri peer system not operating properly Call customer Service Department Motor running but pump not building maximum pressure or has irregular pressure Faucet closed Unit has been stored in freezing temperatures Water inlet screen clogged Kink in garden hose Wand nozzle worm out Air in pump Suction or discharge valves clogged or worn out Open faucet Thaw out unit completely including hose gun and wand Clean screen See section 5 4 Straighten hose Replace spray wand Let pressure washer run with gun open and wand removed until steady stream of water is released Call Customer Service Department 20 HD1400 POWERWASHER 8 0 LOCALIZACI N DE LAS AVER AS PROBLEMAS CAUSAS PROBABLES SOLUCI N El motor no arranca o se detiene durante el funcionamiento Enchufe flojo o no conectado Ha actuado el interruptor t rmico de la hidrolimpiadora El gatillo Power Blast no funciona correctamente Reconectar el ench
24. er inlet hose 5 0 MAINTENANCE 5 1 CONNECTIONS Connections on Pressure Washer hoses gun and spra wand should be cleaned regularly and lubricated wit grease to prevent leakage and damage to the o rings 5 2 NOZZLE The vario spray nozzle should be lubricated regularly Clogging of the nozzle causes the pump pressure to be ioe Fish and cleaning is immediately required see the picture in the next page 1 Separate the nozzle from the wand Fig 8 2 Clear the nozzle 3 Flush the nozzle backwards with water A Reconnect the nozzle to the wand 2 POWERWASHER ATENCI N si se deja secar el jab n las superficies pintadas podr an da arse Laven y sequen una peque a secci n por vez 3 Enjvaguen con agua limpia y con alta presi n Sobre as superficies verticales comiencen a enjuagar antes desde la parte baja hacia la parte alta y luego vice versa Tengan la boquilla a 6 8 pulgadas de la su perficie de trabajo con un ngulo de 45 utilizando el chorro turbo como si fuera una herramienta para pelar en lugar de cepillo de acero APLICACI N DE LA CERA 1 Inmediatamente despu s de la limpieza apliquen la cera con el lanzador de espuma 2 Apliquen la cera lentamente en un estrato unifor me Apliquen sobre superficies mojadas desde abajo ae arriba para distribuirla uniformemen te y para evitar los estriados 3 Extraigan la manguera de aspiraci n del frasco de la cera y eliminen el exceso de cera del aparato
25. h must be replace as part of normal maintenance of the equipment rather than as the result of a defect Transportation charges to warranty center for defective products Transportation charges to consumer for repaired products Damages caused by abuse accident improper repair or failure to perform normal maintenance Use of improper chemicals or noncompliance with the operators manuals instructions Sales outside of the United States or Ca nada Any other expense including consequential damages incidental damages or incidental expenses including damage to property Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty does not cover damage resulting from failure to observe any of the following conditions 1 The inlet water pressure must be between 20 and 100 p s i The inlet water temperature must not exceed 90 degree F 2 The unit should not be stored in areas where temperatures may drop below 32 degrees F 3 23 POWERWASHER Garant a limitada Este producto est garantizado para el comprador original en todos aquellos defectos que surjan en los materiales y en fabricaci n de la m quina durante un periodo de tiempo de un a o 90 d as para la pistola tubo flexible y 90 dias para el interruptor del circuito de fallos de conexi n a tierra GFCI comenzando su validez a partir de la fecha de com
26. introducci n de la hidrolimpiadora de alta presi n 3 3 EMPALME DE LA ALIMENTACION ELECTRICA La hidrolimpiadora tiene como dotaci n est ndar un cable el ctrico y un enchufe GFCI El cable deber ser conectado nicamente a una toma el ctrica instalada en conformidad con las normativas locales de seguridad NOTA La corriente el ctrica deber ser de 120V 60 Hz con un circuito de por lo menos 15 amp ATENCI N controlen el interruptor de cir AN cuito con toma de tierra GFCI antes del uso Noutilicen la m quina de lavar a presi n si el ATENCI N control efectuado da un resultado negativo Procedimiento para controlar el GFCI Procedimientos de prueba del GFCI 1 Conecte el GFCI en la tomacorriente El indicador debe ponerse en rojo 2 Presionar el bot n de prueba test El indicador rojo deber a desaparecer 3 Presione el bot n de reinicio reset para utilizar el equipo No lo utilice si la prueba falla No usar si la prueba descrita anteriormente falla NOTA el GFCI debe ser reseteado todas las veces que se conecta la hidrolimpiadora a una toma el ctrica A Conecten s lo a una toma con una toma de tierra id nea ATENCI N Controlen el cable antes del uso Si est dafiado no lo utilicen C Mantengan secas y fuera de tierra todas las conexiones D No toquen el enchufe con las manos mojadas E La dolar ada es suministrada con un interruptor diferencial autom tico de seguridad instala
27. l sl and a ground fault circuit interrupter GFCI plug This cord should only be connected to an electrical outlet installed in accordance with local safety regulations NOTE The power supply must be 120V 60hz and a minimum 15 amp circuit WARNING test GFCI before each use DO NOT use pressure washer if WARNING fest below fails GFCI Test Procedures 1 Plug GFCI into power receptacle Indicator should turn red 2 Press test button Red indicator should disappear 3 Press reset button for use Do notuse if above test fails NOTE the GFCI must be reset each time the pressure washer is connected to an electrical outlet Reset by simply pushing the reset button on the GFCI power A A Connect only to properly grounded outlet A B Inspect cord before using Do not use WARNING if cord is damaged C Keep all connections dry and off the ground D Do not touch plug with wet hands E The pressure washer is provided with a ground fault circuit interrupter built into the power plug 3 0 CONEXIONES OPERATIVAS 3 1 MANGUERA DE ALTA PRESION Conecten la manguera de alta presi n introduciendo con cautela el accesorio con el O ring en la toma de alta presi n aprieten manualmente la tuerca rosca 3 2 CONEXION DEL AGUA Antes de efectuar la conexi n haga correr el agua en la manguera jard n no incluida en el suministro para hacer salir los materiales extrafios Conecten la manguera jard n a la uni n del agujero de
28. ll not be applicable This warranty gives you specific rights and you may also have other rights which vary from state to state POWERWASHER 2455 PACES FERRY RD N W ATLANTA GEORGIA 30339 4024 1 888 550 1606 Internet Address www hdpowerwasher com Warranty Registration via Internet GARANTIAS IMPLICITAS Cualguier garantia implicita incluyendo las Garantias implicitas de Comercializaci n y de aptitud para un prop sito determinado tienen una duraci n limitada de un a o en la m quina 90 d as para la pistola tubo flexible y 90 d as para el interruptor del circuito de fallos de conexi n a tierra GFCI comenzando su validez a partir de la fecha de compra Algunos Estados no permiten limitaciones en el tiempo de duraci n de la garant a impl cita por lo tanto es posible que dicha limitaci n no se le pueda aplicar a usted C MO OBTENER LAS PRESTACIONES EN GARANT A anexen al producto su nombre domici lio descripci n del ba n mero de tel fono y comprobante de la fecho de la compra al por menor recibo de venta Llamen por tel fono a nuestra Oficina de Asistencia a los Clientes al No 1 888 550 1606 para recibir un n mero de autorizaci n para la restituci n de lo contrario el equipo no ser aceptado Embalen y restituyan el producto gastos de transporte Be do a POWERWASHER Attn Warranty Service Dept 560 S Vermont St Palatine IL 60067 Cualquiera de las cl usulas de la presente garant
29. nmediatamente el filtro y la uni n r pida para evitar que entre material extra o en la bomba ATENCI N no da en el filtro cuando AN lo extraen y lo limpian Cualguier particula gt que pudiera entrar en las bombas ATENCION 5 9 podr a da arla SISTEMA DE REFRIGERACI N Los respiraderos de aire colocados en la hidrolimpiadora y a su alrededor deben ser mantenidos limpios de cualquier obstrucci n para garantizar la refrigeraci n del motor con aire limpio durante el uso IMPORTANTE eviten gue el agua penetre en los respiraderos de la hidrolimpiadora para que el riesgo de da ar ATENCI N a m quina sea m nimo y para reducir el peligro de sacudida el ctrica al operador P HD1400 6 0 SERVICING A DOUBLE INSULATED APPLIANCE In a double insulated product two systems of insulation are provided instead of grounding No grounding means is provided on a double insulated product nor should a means for grounding be added to the pressure washer Servicing a double insulated product reguires extreme care and knowledge of the system and should be done only by gualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INSULATION or DOUBLE INSULATED The following symbol may also be marked on the product 7 0 MOVING AND STORAGE INSTRUCTIONS CAUTION always
30. o hielo en la misma Observen escrupulosamente todas las instrucciones qu micas y las advertencias antes del uso No hay que utilizar la hidrolimpiadora en reas donde hayan vapores gaseosos Una eventual chispa el ctrica podr a provocar una explosi n o un incendio Para reducir al m ximo la cantidad de agua que podr a entrar en la hidrolimpiadora de alta presi n durante el uso colocarla lo m s lejos posible de la zona que debe ser limpiada Con el fin de evitar escapes accidentales cuando no est en uso la pistola de chorro debe estar asegurada con el gatillo de bloqueo No utilicen el equipo cuando est n muy cansados o cuando est n bajo la influencia de alcohol o de drogas Durante el uso NO cubran la hidrolimpiadora de alta presi n con el fin de permitir una ventilaci n adecuada Aprendan c mo bloquear el producto o purgar la presi n r pidamente Adquieran los debidos conocimientos acerca de los diferentes comandos No suban ni se detengan sobre soportes inestables Asuman siempre una posici n firme y segura ATENCI N Riesgo de insuflaci n o de da os No orienten el flujo contra las personas Para obtener informaciones acerca de las Extensiones v anse las CONEXIONES OPERATIVAS en la p gina 12 V ase MANUTENCI N DE UN EQUIPO DE DOBLE AISLAMIENTO Secci n 6 0 CONSERVEN LAS PRESENTES INSTRUCCIONES POWERWASHER PARTS DRAWING HD1400 DISENO PIEZAS
31. pra y es intransferible Esta garant a se aplica s lo para los productos que se utilicen en las aplicaciones de uso y no tiene validez para usos comerciales o de alquiler Les rogamos completen y restituyan la anexa Ficha informativa del Cliente para poder llegar hasta Uds en la improbable eventualidad de que se haga necesario reclamar la mercanc a por motivos de seguridad Registro por Internet al sitio www hdpowerwasher com La restituci n de dicha ficha no es necesaria a los fines de la validez de la presente garant a LA GARANT A CUBRE piezas en substituci n y mano de obra EXCLUSIONES DE LA COBERTURA EN GARANT A la presente garant a no incluye aquellas piezas que como las boquillas deben ser substituidas como piezas de normal manutenci n del equipo y no como consecuencia de un defecto Los gastos por transporte a un centro autorizado por los productos defectuosos Los gastos de transporte al consumidor por los productos reparados Los da os causados por un mal uso accidente reparaci n impropia o falta de manutenci n El empleo de productos qu micos inadecuados y el no respeto de las instrucciones del manual para el uso Las ventas fuera de los Estados Unidos o de Canad Cualquier otro gasto que com prenda da os indirectos da os accidentales o gastos accidentales incluidos los da os a la propiedad Algunos Estados no permiten la exclusi n o la limitaci n de los da os accidentales o indirectos por lo t
32. pressure washer to stop A WARNING WARNING the pressure washer is also equipped with a main power on off switch located on the unit It should always be moved to the off position when the pressure washer is not being used to prevent possible injury or damage MOTOR OVERLOAD The electric motor in this pressure washer is eguipped with an overload protection device which will automatically shut off the motor in the event the motor draws excessive current or overheats The device will automatically reset itself and resume normal operation after a short period of time ATENCI N Conexi n apropiada del agua A 2 0 CARACTER STICAS RELATIVAS A LA SEGURIDAD La hidrolimpiadora de presi n est dotada de un dispo sitivo de stop que detecta cu ndo est desenganchado suelto el gatillo de la pistola Abre el circuito el ctrico al motor y bloquea la hidrolimpiadora de presi n A ATENCI N ATENCI N la hidrolimpiadora de presi n est tambi n equipada con de un interruptor el ctrico principal ON OFF Cuando la hidrolimpiadora no est en uso es necesario que dicho interruptor est colocado siempre en OFF para pre venir posibles accidentes o da os SOBRECARGA DEL MOTOR El motor el ctrico de la hidrolimpiadora posee un di spositivo de protecci n contra la sobrecarga que bloquea autom ticamente el motor en el caso de exceso de corriente o en el caso de recalentamiento El dispositivo se resetea autom ti
33. r diferentes operaciones s lo con el agua en muchos casos sin embargo es conveniente utilizar tambi n un detergen te El uso de un detergente asegura un tratamiento inmediato de la 2 permitiendo al agua con alta presi n penetrar y eliminar eficazmente la suciedad La baja presi n permite aplicar en modo delicado el jab n y o la cera Se recomienda el uso de la baja presi n para enjuagar una superficie despu s de la aplicaci n de cera o para otras aplicaciones que requieren la baja presi n de una manguera de jard n La baja presi n corresponde a la e de la manguera de jard n a la potencia menor para aplicar en modo correcto el jab n y la cera PARA APLICAR JABON CERA INSERTEN EL LANZADOR DE ESPUMA APLICACI N DE JAB N l Apliquen la soluci n de kal de la hidrolimpiadora sobre una superficie de trabajo SECA NOTA NO SE ACONSEJA MOJAR LA SUPERFICIE ANTES PUESTO GUE DILUYE EL DE TERGENTE Y REDUCE SU CAPACIDAD DE LIMPIEZA Ante la presencia de una superficie comenzando por la parte baja para evitar estriados ATENCION eviten trabajar sobre AN sol para disminuir lo m s posible las superficies pintadas 2 Antes de enjuagar dejen el jab n sobre la super vertical apliquen el jab n horizontalmente superficies calientes o a la luz directa del ATENCI N posibilidades de que el jab n da e las ficie durante un breve lapso de tiempo HD1400 CAUTION damage may occur to painted surface if soap is allowed
34. raci n o de descarga obturadas o fuera de uso Abran el grifo Descongelar completamente el equipo incluidos las mangueras la pistola y el lanzador Limpien el filtro V ase secci n 5 4 Enderecen la manguera Substituyan el lanzador de chorro Dejen en funcionamiento la hidrolimpiadora con la pistola abierta y el lanzador desplazado hasta que se obtenga un flujo de agua regular Consulten con la Oficina de Asistencia Clientes 21 HD1400 POWERWASHER 9 0 TECHNICAL DATA Pump pressure Electrical reguirement Electrical cord High Pressure hose Flow rate Minimum amperage source Pressure of inlet water Inlet water Nozzle spray angle high pressure See injection rate 1400 psi Man Operation pressure 120v 15 amps 60 hz 35 ft 19 ft 1 5 gpm 15 amp 20 to 100 psi cold tap water 0 60 2 to 4 Water flow and maximum pressure ratings determined in accordance with PWMA Standard PW101 Please Call Us First If there are missing or damaged parts DO NOT RETURN THIS PRODUCT TO THE STORE Our Customer Service Department is available to help with any problems and operational questions Our toll free number 1 888 550 1606 9 0 DATOS TECNICOS Presi n bomba 1400 psi Presi n de uso man Necesidades de electricidad 120V 15 Amp 60 Hz Cable el ctrico 35 pies Manguera alta presi n 19 pies Capacidad 1 5 gpm Fuente m nima
35. ransferencia y la manutenci n del equipo mec nico Utilizando los aparatos con el respeto y la cautela requeridos las posibilidades de provocar da os personales disminuir n notablemente Si se descuidara o ignorara tomar estas precauciones de seguridad se 511 verificar da os a las personas o al equipo Los simbolos que describiremos a continuaci n son bado ampliamente en el presente manual Tengan siempre en cuenta dichas precauciones puesto que son esenciales cuando se utiliza el equipo mec nico es el s mbolo que identifica las instrucciones para procedimientos espec ficos si no son aa pueden PELIGRO provocar da os personales o la muerte este s mbolo identifica las instrucciones de procedimientos espec ficos que si no son observadas rigurosamente pueden IMPORTANTE Provocar da os o hasta la destrucci n el equipo mismo Esta unidad ha sido dise ada para aplicaciones espec ficas No hay que aportar modificaciones y o utilizarla para aplicaciones diferentes de aquellas para las cuales ha sido pensada Si tienen preguntas en relaci n con su aplicaci n escriban o llamen por tel fono No utilicen la m quina hasta haber recibido las respuestas a sus preguntas A PELIGRO 1 Lean atentamente el presente manual para conocer su equipo Tomen en debida consideraci n sus aplicaciones limitaciones y los potenciales riesgos espec ficos 2 El aparato debe ser conectado exclusivamente a una toma de alimentaci
36. screen from the pump inlet Backflush screen to clean Replace screen and quick connect immediately to prevent any foreign matter from entering the pump CAUTION do not damage the screen while removing or cleaning Any foreign particles entering the pump may damage CAUTION he pump 5 5 COOLING SYSTEM The air vents located in and around the pressure washer must be kept clean and free of any obstructions to ensure proper air cooling of the motor during operation WARNING prevent water from penetrating the vents of the pressure washer to minimize the risk of damage to CAUTION the machine and to reduce the risk of shock to the operator 18 5 3 LUBRICACI N La hidrolimpiadora ha sido creada con un sistema de lubricaci n permanente No son necesarios controles convencionales ni la substituci n de aceites NOTA EN El CASO DE PERDIDA DE ACEITE CONTACTEN AL SERVICIO CLIENTES DE LA SOCIEDAD FAIP NORTH AMERICA SECCION REPARACIONES UNA PEQUENA PERDIDA DE ACEITE ES NORMAL 5 4 FILTRO AGUA La hidrolimpiadora est dotada de un filtro de introducci n de agua para proteger la bomba ATENCI N si no se mantiene limpia el Hs el e del i la gt hidrolimpiadora se ve limitado y la bom ATENCION puede da arse 1 Para limpiar el filtro c nico m s interno del agua extraigan la uni n r pida y el filtro de pl stico de introducci n de la bomba El filtro de retorno flujo debe estar limpio Substituyan i
37. stre el n mero de serie y la fecha de compra en el siguiente espacio me de Serie m de Compra If 200 FOR EASY INSTALLATION INSTALACI N F CIL REMOVE THE WATER PLUG EXTRAIGA EL TAPON DEL AGUA CONNECT THE HIGH PRESSURE HOSE CONECTE LA MANGUERA DE ALTA PRESION CONNECT THE GARDEN HOSE CONECTE LA MANGUERA JARDIN CONECTE CON EL SUMINISTRO DE O CONNECT TO WATER SUPPLY AGUA INSERT THE WAND INTO THE SPRAY GUN INTRODUZCA EL TUBO EN LA PISTOLA ROCIADORA wee NOTE Make sure wand is locked NOTA Aseg rese de que el tubo est cerrado CONECTE EL GFCI EN EL TOMACORRIENTE Y PRESIONE EL PLUG GFCI INTO POWER RECEPTACLE AND PRESS RESET BUTTON BOTON DE REINICIO RESET REINICIO TEST PRUEBA ND t TURN ON WATER SUPPLY ABRA EL SUMINISTRO DE AGUA START THE PRESSURE WASHER ENCIENDA LA M QUINA DE LAVAR A PRESI N ON ENCENDIDO OFF APAGADO CAREFULLY READ THE OPERATORS INSTRUCTIONS FOR USE BEFORE STARTING UP THE WASHER FOR THE FIRST TIME IMPORTANT LEA ATENTAMENTE EL MANUAL DE INSTRUCCIONES ANTES DE PONER EL EQUIPO POR PRIMERA VEZ EN HD1400 INDEX 1 0 SAFETY AND OPERATION RULES page 8 2 0 SAFETY FEATURES page 11 3 0 OPERATING CONNECTIONS page 12 3 1 HIGH PRESSURE HOSE
38. to dry on the surface Wash and rinse a small section at a time 3 Rinse with clean water under high pressure On a vertical surface first rinse from the bottom up then rinse from the top down Hold nozzle 6 to 8 inches from the work surface at a 45 angle using the tur bo spray as a peeling tool rather than a scrub brush APPLICATION OF LIQUID VEHICLE WAX 1 Immediately after cleaning apply liquid vehicle wax using the soap dispenser assembly Apply the wax oral in an even layer Apply to wet surfaces from the bottom up for even distribution and to avoid streaking 2 3 Remove the suction tube from the bottle and rinse off the surplus wax from your vehicle under low pressure NOTE IF SURPLUS WAX IS NOT REMOVED A HAZY FINISH MAY RESULT 4 Wipe dry to reduce water spotting 4 5 END OF OPERATION When you have completed use of the soap wax application remove bottle and flush clean water through the tube until it is thoroughly cleaned NOTE Failure to clean properly will cause the injection system to become and inoperable 1 Stop the machine by pressing the on off button 1 Disconnect electrical plug 1 off water and depressurize unit by squeezing trigger AN sgueeze trigger to depressurize the unit Failure to do so could result in personal injury WARNING due to discharge of high pressure water WARNING turn off water supply and 1 Disconnect the high pressure discharge hose and the wat
39. uctions or procedures which if no strictly observed could result in damage to or destruction of equipment This unitwas designed for specific applications It should not be modified and or used for any application other than that which it was designed If there are any questions regarding its application write or call Do not use this unit until your questions have been answered when ed this product basic precautions should always be followed WARNING including the following 1 Read this manual carefully know your equipment Consider the d limitations and the potential hazards specific to your unit 2 This Hood shall only be connected to a power supply receptacle protected by a ground fault circuit interrupter 3 Do not touch plug or outlet with wet hands Avoid accidental starts Move switch on unit to OFF position before connecting or disconnecting cord to electrical outlets 5 Water spray must never be directed towards any electric wiring or directly towards the pressure washer machine itself or fatal electric shock may occur 6 Never carry your pressure washer by the cord Do not pull on the cord to disconnect from the outlet 7 To prevent damage the cord should not be crushed placed next to sharp objects nor near a heat source Cuando se trata de un equipo mec nico las precauciones inherentes a la seguridad son esenciales Por ello es necesario adoptar dichas precauciones du rante el uso la t
40. ufe Dejen enfriar y hagan arrancar nuevamente el equipo Soliciten la ayuda a la Oficina de Asistencia Clientes El interruptor del circuito actua o est n quemados los fusibles en la caja de fusibles Sobrecarga circuito Extensi n demasiado larga o dimensi n del cable demasiado peque a Boquilla parcialmente bloqueada Presi n excesiva Controlen que el circuito est regulado en 15 o m s amp Desconecten todas las cargas del circuito Usen una extensi n id nea como aconsejado en el Manual del Operador Limpien la boquilla como indicado en la secci n 5 2 Limpien la boquilla como indicado en la secci n 5 2 Hay p rdidas de agua y aceite desde el fondo de la bomba Una peque a p rdida es normal Si la p rdida es excesiva hay que contactar la Oficina de Asistencia Clientes El gatillo no se mueve Est conectado el bloqueo de seguridad de la pistola aa kal el blogueo de seguridad EI eguipo no se detiene cuando el gatillo est desenganchado EI sistema del gatillo Power Blast no funciona correctamente Contacten la Oficina de Asistencia Clientes El motor gira pero la bomba no suministra la m xima presi n o tiene una presi n irregular Grifo cerrado El equipo ha sido almacenado a temperaturas muy fr as El filtro de introducci n agua est obturada Pliegues de la manguera de jard n Boquilla lanzador inutilizable Aire en la bomba V lvulas de aspi
Download Pdf Manuals
Related Search
Related Contents
Manual de servicio - Power Electronics User Manual TSM400 DE Yaskawa E7B Drive O&M - Coward Environmental Systems Kinetics Manual Weatherables LWPT-CORNER-4X84 Use and Care Manual Fiche Produit CPA2500 manual - Chord Electronics STATION MÉTÉO SANS FIL 868 MHz 目 录(目录名) - Uniview Copyright © All rights reserved.