1. e HAY WARD POOL PRODUCTS CANADA INC 2880 PLYMOUTH DRIVE OAKVILLE ONTARIO L6H 5R4 905 829 2880 e Produits De Piscines Hayward Canada Inc Titulaire de licence www haywardcanada com NUMERO DE PIECES N de z Nombre r f DESIGNATION requis MOD LE MOD LE SP 2290 ET SP 2295 ET Joint tanche du couvercle de la cr pine en Lexan transparent 1 SP1500P Panier SP1500LX Cr pine SP1500CP Bouchon de vidange facultatif SP1700FG SP1700FG Bouchon vidange et rondelle facultatif SP1700FG Joint torique SP1500W SP15808P 1 SP1500F 12 Ensemble de joint tanche SP1500KA 13 Batidela pompe SP1580AAP 4 crou hexagonal no 10 24 8 SP1500Y2 SP1500Y2 15 Manchon d arbre SP150005 SP150005 16 Moteur SP1514ZIUF 17 Protecteur SP2090B 18 Carter du moteur SP2090A 19 Couvercle de la minuterie m canique T SP2090CAM 19b Couvercle de la minuterie lectronique ET SP2090CETM 0 Boulon de retenue du moteur au carter 4 Pour commander pr ciset le fabricant du moteur le nombre de CV et le no du mod le de la pompe 1 Socle de montage sur lev facultatif SP5500M 2 Cordon d alimentation SP1550WA7C NIN www haywardcanada com MINUTERIE ELECTRONIQUE INSTRUCTIONS Vote minuterie int gr e a t concue pour tre programm e en fonction de vos besoins en filtration selon quatre niveaux de r glage REGLAGE DE LA MINUTERIE 1 Mettre l interrupteur de la position lt lt OFF g
2. MISE EN MARCHE ET LAMORCAGE Remplir compl tement la cr pine le b ti d eau Ne jamais mettre la pompe en marche vide L eau joue le r le de r frig rant et de lubrifiant pour le joint d arbre m canique Ouvrir toutes les soupapes de succion et de d charge ainsi que le chasse air s il y a lieu du filtre L air devant tre chass du conduit de succion doit d boucher quelque part Mettre la pompe en marche et pr voir une p riode d amor age d pend de la hauteur d aspiration et de la longueur horizontale du tuyau de succion Si la pompe ne d marre pas ou ne s amorce pas consulter le GUIDE DE D PAN NAGE la derni re page Note L article V de la norme NSPI 4 concernant les piscines hors terre et les piscines creus es indique que les composantes telles que les syst mes de filtration les pompes et les chauffe eau ne doivent pas tre plac s de fa on ce qu ils puissent tre utilis s par les jeunes enfants comme un moyen d acc s la piscine 4 Les joints de l arbre peuvent l occasion s endommager ou s user et ils doivent alors tre remplac s Consulter les instructions PR PARATIFS EN VUE DE L HIVER ENTREPOSAGE La pompe et le moteur doit tre prot g s contre le gel Couper l alimentation lectrique D brancher le cordon les connexions lectriques et les raccords de la tuyauterie Vider compl tement et enlever tous les d bris Ranger la pompe et le moteur dans une pi ce s che et bien a r
3. QUE VOS R GLAGES AIENT PR S ANCE SUR CEUX DU PROGRAMME Faire passer l interrupteur de lt lt RUN gt gt MARCHE lt lt OFF gt gt ARR T puis la remettre lt lt RUN gt gt MARCHE en moins de trois secondes La pompe se mettra en marche pour une p riode d une heure puis retournera au mode programm pr c demment En cas de panne de courant la minuterie retournera automatiquement la programmation en cours d s le r tablissement du courant RENSEIGNEMENTS G N RAUX Faire preuve d une grande prudence au moment de manipuler et d installer le nouvel ensemble de joint tanche et de si ge Les surfaces chevauch es et polies peuvent facilement tre endommag es par la salet ou les gratignures titre s curitaire couper le courant avant de proc der l entretien Couper l alimentation lectrique et d brancher le cordon lectrique Sortir l ensemble pompe moteur du syst me de tuyauterie Si un socle de montage sur lev facultatif a t install l ensemble de la pompe peut tre s par du socle sur lev en appuyant sur le loquet ressort sur le dessus du socle et en glissant l ensemble de la pompe vers l arri re Enlever le couvercle d extr mit du carter du moteur en d vissant les deux 2 vis Soulever soigneusement le couvercle l cart du moteur et d brancher les fils reli s aux bornes du moteur Enlever le couvercle du b ti de la pompe avec la cr pine en place en d
4. vissant les huit 8 boulons et crous de retenue du couvercle au b ti de la pompe La turbine est alors expos e Pour d monter la turbine glisser un tournevis dans la fente pratiqu e l extr mit du moteur Tenir le tournevis de fa on emp cher l arbre de tourner et tourner la turbine dans le sens contraire des aiguilles d une montre La partie des ressorts de l ensemble de joint tanche est maintenant expos e Remarquer la position exacte du joint tanche ressorts avant de le tirer l cart de la turbine Pour enlever la partie fixe de l ensemble de joint tanche si ge en c ramique a Desserrer les quatres 4 boulons de retenue du moteur et d monter le moteur du b ti de la pompe b Une fois le moteur enlev sortir l ensemble de si ge en c ramique et en plastique transparent du logement en retrait du b ti de la pompe en appuyant S il est serr le frapper l g re ment du c t du moteur Nettoyer et lubrifier l arbre du moyeu de la turbine et le logement en retrait du joint tanche du b ti de la pompe Utilisez du silicone ou le lubrifiant de joint torique Jack No 327 Essuyer doucement la face polie du nouveau si ge en c ramique au moyen d un linge en coton douc et sec Poser la nouvelle partie des ressorts de l ensemble sur la turbine en appuyant la surface noire polie l cart de la turbine Vous assurer que le joint torique en caoutchouc noir est en place sur le bord coup du dispo
5. IS 2290 HC 08 HAYWARD Hi Performance above ground SELF PRIMING PUMPS INSTALLATION AND OPERATING INSTRUCTIONS Ultra Pro LX sens Your Hayward Ultra Pro LX pump has been quality built and engi neered to give you many years of efficient dependable service The non conductive corrosion proof motor housing provides protection from the elements and insulates the electrical motor parts from outside contact The advanced design reduces operation and maintenance to simple common sense procedures GENERAL TIPS ON PUMP INSTALLATION For best pump performance locate the system below the pool water line and as close to the pool as possible Ifyou own an above ground pool please see Note NSPI 4 Article V for safe and proper installation of the equipment package Make sure suction joints are tight Suction pipe should be as large or larger than discharge pipe Damp non ventilated locations should be avoided Motors require free circulation of air to aid in cooling Insure that the electrical supply available agrees with the motor s voltage phase and cycle and that wire size is adequate for the HP KW rating and distance from the power source Motor must always be properly grounded If cord connected use only a properly grounded outlet Electrical circuits should be protected by proper size ground fault circuit interrupter GFCI All electrical wiring should be performed by qualified personnel and must conform to local codes and regula
6. S AMORCE PAS Vous assurer que la cr pine de la pompe est rempli d eau et que le joint torique du couvercle de la cr pine est propre et solidement en place Vous assurer galement que le couvercle de la cr pine repose fermement en place Vous assurer que toutes les soupapes de succion et de d charge sont ouvertes et ne sont pas obstru es et que le niveau d eau de la piscine d passe toutes les ouvertures de succion Si le vide se fait dans la pompe v rifier si le conduit de succion ou la cr pine sont bloqu s ou s il y a une fuite d air dans le tuyau de succion Sile vide ne se fait pas dans la pompe et si la pompe poss de suffisamment d eau d amorcage Serrer tous les boulons et raccords du c t de la succion V rifier la tension pour vous assurer que la pompe fonctionne la vitesse convenable Ouvrir la pompe et v rifier si elle est bouch e ou obstru e Enlever et remplacer le joint de l arbre FAIBLE DEBIT En g n ral v rifier Cr pine ou conduit de succion bouch s ou entrav s tuyauterie de piscine de calibre insuffisant Conduit de d charge du filtre bouch ou entrav lecture lev e de l indicateur de d charge Fuite d air dans le conduit de succion bulles sortant des raccords de retour Fonctionnement basse vitesse de la pompe basse tension Turbine bouch e ou entrav e POMPE BRUYANTE V rifier Fuite d air
7. and nuts which fasten housing cover to pump housing The impeller is now exposed To remove impeller insert screwdriver in slot at end of motor Hold screwdriver so as to keep shaft from turning and rotate the impeller in a counterclockwise direction The spring portion of the seal assem bly is now exposed Note carefully the position of the spring seal and pull it off the impel ler To remove the stationary ceramic seat part of the seal assembly a Loosen the four 4 motor securing bolts and disengage the motor with motor housing in place from the pump housing b With motor removed press the clear plastic and ceramic seat assembly out of the pump housing recess If tight tap lightly from the motor side 07 08 09 10 11 12 13 14 Clean and lubricate the impeller hub shaft and pump housing seal recess Use silicone or Jack s No 327 O Ring lube Gently wipe the polished face of the new ceramic seat with a soft dry cotton cloth Press the new spring portion of the assembly onto the impeller black polished surface facing away from the impeller Be sure black rubber O Ring is in place on cut ridge of clear plastic seat retainer Press plastic retainer with ceramic seat inside into recess of pump housing O Ring end first Seat the assembly firmly and evenly using finger pressure Carefully insert the motor shaft thru the seat assembly and secure motor and motor housing to pump housing w
8. dans le conduit de succion causant le ronfle ment de la pompe Affaissement provoqu par un conduit de succion entrav ou trop petit et des conduits de d charge non entrav s Rem dier au probleme de succion ou trangler les conduits de d charge si c est plus pratique Vibrations provoqu es par le montage mal effectu etc Pr sence de corps trangers dans le bati de la pompe Paliers du moteur us s rouill s ou surchauff s continu ellement ENTRETIEN ET REPARATION Consulter votre d positaire ou centre d entretien Hayward autoris r gional Aucune pompe ni aucun moteur ne doivent tre retourn s directement l usine sans le consentement pr alable par crit de Produits de Piscines Hayward Canada Inc www haywardcanada com
9. ement le c t plat de l arbre du moteur arri re au moyen d une cl pour emp cher l arbre de tourner www haywardcanada com A V rifier si les raccords sont mal effectu s ou desserr s C LE MOTEUR RONRONNE MAIS NE DEMARRE PAS GUIDE D LECTRICIT MOTEURS MONOPHASES 60 CYCLES MOTEUR cy KW VOLTS 75 142 PUISSANCE NOMINALE A DISJONCTEUR CALIBRE RECOMMAND DES FILS 0 50 0 15m No 12 No 12 GUIDE DE D PANNAGE LE MOTEUR NE D MARRE PAS si les interrupteurs ou relais sont ouverts si les fusibles sont grill s ou si les disjoncteurs sont d clench s V rifier manuellement la rotation de l arbre du moteur pour voir s il tourne librement ou s il est obstru LE MOTEUR S ARR TE V rifier C blage raccords desserr s etc Basse tension du moteur fr quemment caus e par des fils de calibre insufficient Coincement et surcharge lecture de l amp rage REMARQUE Le moteur de votre pompe Hayward est muni d une protection thermique automatique contre les surcharges Le moteur s arr te automatiquement dans des conditions normales avant que l accumulation de chaleur ne puisse l endommager dans l ventualit d un d faut de fonctionnement Il se remet automatiquement en marche d s que la temp rature est revenue la normale V rifier 1 2 Commutateur de la centrifugeuse coinc en position ouverte Coincement de l arbre du moteur LA POMPE NE
10. g 3 Pump runs 12 hours on Hi 12 hours on Low 3 tones Setting 4 Pump runs 6 hours on Hi 18 hours on Low 4 tones 01 02 03 04 05 06 SINGLE SPEED MOTOR SETTINGS Setting 1 Pump runs 24 hours Continuous single tone Setting 2 Pump runs 18 hours off 6 hours 2 tones Setting 3 Pump runs 12 hours off 12 hours 3 tones Setting 4 Pump runs 6 hours off 18 hours 4 tones TO OVERIDE TIMER SETTINGS Move switch from RUN to OFF and back to RUN within 3 seconds The pump will run for 1 hour and then return to the previous programmed setting If a power failure occurs the timer automatically returns to the programmed setting SEAL CHANGE INSTRUCTIONS Exercise extreme care in handling and installing the new seal and seat assembly The lapped and polished surfaces may easily be damaged by dirt or scratching For safety all service must be performed with all power shut off Turn off power and unplug power cord Remove pump and motor assembly from piping system If optional elevated mounting base was installed pump assembly can be disengaged from elevated base by depressing spring catch on top of base and sliding pump assem bly out to the rear Remove motor housing end cover by removing two 2 screws Carefully pull cover away from motor and disconnect wires from motor terminals Remove pump housing cover with strainer attached by removing the eight 8 housing bolts
11. ischarge lines Correct suction condition or throttle discharge lines if practical Vibration due to improper mounting etc Foreign matter in pump housing Motor bearings made unserviceable by wear rust or continual overheating SERVICE AND REPAIRS Consult your local authorized Hayward dealer or service center No pumps or motors may be returned directly to the factory without the express written authorization of Hayward Pool Products Canada Inc www haywardcanada com IS 2290 HCF 08 POMPES POUR PISCINES HORS TERRE AUTO AMORCANTES A GRAND RENDEMENT HAYWARD INSTRUCTIONS POUR L INSTALLATION ET LE FONCTIONNEMENT Ultra Pro LX seres Votre pompe Ultra Pro LX de Hayward a t con ue et fabriqu e avec un soin minutieux en vue de vous procurer un rendement fable et efficace pendant de nombreuses ann es Le carter du moteur non conducteur l preuve de la corrosion protege les l ments et isole les pieces lectriques du moteur de tout contact avec l ext rieur Sa conception perfectionn e a beaucoup simplifi son fonction nement et son entretien CONSEILS G N RAUX SUR L INSTALLATION DE LA POMPE Pour favoriser le rendement de la pompe placer le syst me en dessous du niveau d eau de la piscine et aussi pr s de la piscine que possible Si vous poss dez une piscine hors terre veuillez lire la note au sujet de l article V de la norme NSPI 4 qui concerne l installation s curitaire et ad quate des a
12. ith four 4 motor securing bolts Be sure motor housing mounting bracket is positioned properly Screw the impeller with spring seal onto the motor shaft hand tight by turning clockwise Clean housing O Ring replace if necessary and fasten housing cover to pump housing with eight 8 bolts and nuts Tighten bolts and nuts alternately and evenly Reconnect electric wires from power cord and timer to pump motor terminals Both white wires to line 2 both black wires to A red timer wire to line 1 Ground wire to ground screw on motor Replace cover and secure with two 2 screws Reconnect pump to piping system Be sure to fill strainer with water before restarting www haywardcanada com D ELECTRICAL GUIDE 60 CYCLE MOTORS SINGLE PHASE MOTOR HP KW VOLTS 75 112 TROUBLE SHOOTING GUIDE MOTOR WON T START Check for improper or loose connections open switches or relays blown circuit breakers or fuses Manually check rotation of motor shaft for free movement and lack of obstruction MOTOR CUTS OUT Check for Wiring loose connections etc Low voltage at motor frequently caused by undersized wiring Binding and overload Amperage reading NOTE Your Hayward pump motor is equipped with Automatic Thermal Overload Protection The motor will automatically shut off under normal conditions before heat damage build up due to an improper operating condition can occur The motor will au
13. ore pump and motor in a dry well ventilated room HAYWARD POOL PRODUCTS CANADA INC 2880 PLYMOUTH DRIVE OAKVILLE ONTARIO L6H 5R4 905 829 2880 e Hayward Pool Products Canada Inc Licensee www haywardcanada com PART NUMBER DESCRIPTION Non 4 EF MODEL SP2290 ES SP 2295 ET 1 strainercover pr s SPI680OE O Strainer Cover w o ring OT SPISOOP O SP1500P 3 Basket RE EE SPTSOOLX A strainer Housing Pise SP1500CP 5 Drain Plug optional SPI700FG SP1700FG 7 5P1500W 5P1580BP SP1500F SP1500KA SPTSBOAAP 15 ShaftSleve 1 SSOS SP150005 19 Motor End Cover 1 SP2090CAM SP2090CAM 19b Timer End Cover Electronic ET SP2090CETM To order specify manufacturer HP and Model No 21 Beated Mouning base TT Sssom SP5500M 23 Base Noise Reduction Insert SP5500MFB SP5500MFB www haywardcanada com ELECTRONIC TIMER MODULE INSTRUCTIONS Your integrated timer module is designed to be programmed to your filtration need with four 4 possible settings TO SET TIMER 1 Move switch OFF to PROGRAM back to OFF resulting single tone indicates Setting 1 Repeat until number of tones heard equals setting desired ie 3 rapid tones is Setting 3 2 Move switch from OFF to RUN to begin selected program setting TWO SPEED MOTOR SETTINGS Setting 1 Pump runs 24 hours on Hi Speed single tone Setting 2 Pump runs 18 hours on Hi 6 hours on Low 2 tones Settin
14. ppareils et des syst mes Vous assurer que les joints du conduit de succion sont bien serr s Le conduit de succion doit tre aussi gros ou plus gros que le conduit de d charge viter les endroits humides et mal a r s L air doit circuler librement dans le moteur pour en assurer le refroidissement convenable Vous assurer que l alimentation lectrique est conforme la tension le phasage et le cycle de fonctionnement du moteur et que le calibre des fils convient la puissance nominale en CV KW et la distance qui s pare le moteur de la source d alimentation Le moteur doit toujours tre reli convenablement la terre S il y a branchement au moyen d un fil utiliser une prise de courant correcte ment mise la terre Les circuits lectriques doivent tre prot g s au moyen d un disjoncteur d tecteur de fuite la terre DDFT de format appropri ENTRETIEN 1 Nettoyer la cr pine r guli rement Ne pas la frapper pour la nettoyer Examiner le joint du couvercle de la cr pine r guli rement et le remplacer au besoin 2 Les pompes Hayward sont munies de paliers de moteur et de joints d arbre autolubrifiants Nul besoin de les lubrifier 3 Garder le carter du moteur propre Vous assurer que les prises d air ne sont pas obstru es par quoi que ce soit Tout le c blage lectrique doit tre effectu par un personnel qualifi et doit respecter les codes et r glements locaux INSTRUCTIONS POUR LA
15. sitif de retenue du si ge en plastique transparent Enfoncer le dispositif de retenue en plastique contenant le si ge de c ramique dans le logement en retrait du b ti de la pompe le bout du joint torique en premier Appuyer du bout des doigts sur l ensemble pour le faire reposer solidement et uniform ment en place 10 Ins rer soigneusement l arbre du moteur dans l ensemble du si ge et fixer le moteur au b ti de la pompe au moyen des quatres 4 boulons de retenue du moteur Vous assurer que la base du moteur repose convenablement en place 11 Visser la turbine et le joint tanche ressorts l arbre du moteur la main dans le sens des aiguilles d une montre 12 Nettoyer le joint torique du carter remplacer au besoin et fixer le couvercle du carter au carter de la pompe l aide de huit 8 boulons et crous Serrer les boulons et crous en alternant et de fa on uniforme 13 Raccorder les fils lectriques du cordon d alimentation et de la minuterie sur les bornes du moteur de la pompe Les deux fils blancs sur la ligne 2 les deux fils noirs sur A le fil rouge de la minuterie sur la ligne 1 Raccorder le fil de mise la terre sur la vis de mise la terre du moteur Replacer le couvercle et le fixer avec deux 2 vis 14 Raccorder la pompe au syst me de tuyauterie Vous assurer que la cr pine soit remplie d eau avant de remettre la pompe en marche Dans le cas des moteurs A O Smith tenir soigneus
16. t gt ARR T la position lt lt PROGRAM gt gt PROGRAMMER puis le remettre lt lt OFF gt gt ARR T ce qui produira une tonalit simple indiquant que la minuterie est r gl e au niveau 1 Reprendre le processus jusqu ce que le nombre de bips indique le niveau souhait Par exemple une tonalit triple rapide indique le niveau 3 2 Mettre l interrupteur de la position lt lt OFF gt gt ARR T la position lt lt RUN gt gt MARCHE pour activer la minuterie selon la programmation choisie R GLAGE DU MOTEUR DEUX VITESSES Niveau 1 La pompe fontionne haute vitesse pendant 24 heures tonalit simple Niveau 2 La pompe fontionne haute vitesse pendant 18 heures et basse vitesse pendant 6 heures tonalit double Niveau 3 La pompe fontionne haute vitesse pendant 12 heures et basse vitesse pendant 12 heures tonalit triple Niveau 4 La pompe fontionne haute vitesse pendant 6 heures et basse vitesse pendant 18 heures tonalit quadruple R GLAGE DU MOTEUR UNE VITESSE Niveau 1 La pompe fontionne pendant 24 heures en continu tonalit simple Niveau 2 La pompe fontionne pendant 18 heures et demeure inactive pendant 6 heures tonalit double Niveau 3 La pompe fontionne pendant 12 heures et demeure inactive pendant 12 heures tonalit triple Niveau 4 La pompe fontionne pendant 6 heures et demeure inactive pendant 18 heures tonalit quadruple POUR
17. tions MAINTENANCE 1 Clean strainer basket regularly Do not strike basket to clean Inspect strainer cover gasket regularly and replace as necessary Hayward pumps have self lubricating motor bearings and shaft seals No lubrication is necessary Keep motor housing clean Insure air vents are free from obstructions debris etc STARTING AND PRIMING INSTRUCTIONS Fill strainer housing completely with water Never operate the pump without water Water acts as a coolant and lubricant for the mechanical shaft seal Open all suction and discharge lines and valves as well as air bleed if available on filter The air that is to be displaced from the suction line must have some place to go Turn on power and allow a reasonable time for priming Priming time depends on suction lift and length of suction piping If pump will not start or will not prime see TROUBLE SHOOTING GUIDE on back page Note NSPI 4 Article V standard for above ground and on ground pools advises that components such as the filtration system pumps and heater be positioned so as to prevent their being used as a means of access to the pool by young children 4 Occasionally shaft seals must be replaced due to wear or damage See instructions STORAGE WINTERIZING Pump and motor must be protected from freezing Shut off all electric power Disconnect cord electrical connections and plumbing connections Drain thoroughly and clean out any debris St
18. to restart when safe heat level is reached MOTOR HUMS BUT DOES NOT START Check for Centrifugal switch stuck in open position Binding of motor shaft PUMP WON T PRIME Make sure pump strainer housing is filled with water and that cover O Ring is clean and prop erly seated Make sure strainer cover is locked firmly in position Make sure all suction and discharge valves are open and unobstructed and that pool water level is above all suction openings Circuit Breaker RATING AMPS O 9 RECOMMENDED WIRE SIZE 0 50 0 15m No 12 No 12 If pump develops a vacuum check for blocked suction line or strainer or air leak in suction piping If pump does not develop a vacuum and pump has sufficient priming water Tighten all bolts and fittings Check voltage to make sure pump is up to speed Open pump and check for clogging and obstruc tion Remove and replace shaft seal LOW FLOW Generally Check for Clogged or restricted strainer or suction line undersized pool piping Plugged or restricted discharge line of filter high discharge gauge reading Air leak in suction bubbles issuing from return fittings Pump operating underspeed low voltage Plugged or restricted impeller F NOISY PUMP Check for A Air leak in suction causing rumbling in pump Cavitation due to restricted or undersized suction line and unrestricted d

Download Pdf Manuals

image

Related Search

Related Contents

Grandstream Networks, Inc. GXV3611 User Manual  Samsung AZ09FATEA manual de utilizador  GT16 User`s Manual (Hardware)  Mini-2Bay NAS-RAID Subsystem, (RAID 0, 1 selectable) w/ RJ45  Conair LWD1P User's Manual  VI410 Vibration Monitor User Manual  How to Install Autodesk NavisWorks Manage 2009  AT&T 3G MicroCell™ User Manual  