Home

DELUXE JET AIR THERAPEUTIC AIR

image

Contents

1. Y Mirolin DELUXE JET AIR THERAPEUTIC AIR Air Massage and Whirlpool Combinations INSTALLATION AND OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION OF YOUR AIR MASSAGE COMBINATION BATH PLEASE RECORD THE SERIAL NUMBER OF YOUR AIR MASSAGE BATH AND SAVE THIS MANUAL FOR FUTURE REFERENCE NOTE These instructions are to be used along with the installation instructions for ACRYLIC BATHTUBS WARNING When using electrical products basic precautions should always be followed including the following 1 DANGER RISK OF ELECTRICAL SHOCK Connect only to a circuit protected by a ground fault circuit interrupter GFCI 2 Grounding is required An equipment grounding terminal is provided in the field wiring compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment 3 INSTALL THIS UNIT IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE PART 1 OR THE APPROPRIATE CODE IN OTHER COUNTRIES 4 INSTALL TO PERMIT ACCESS FOR SERVICING 5 Provide adequate ventilation for the motor to prevent nuisance trips of the thermal overload protection INSTALLATION NOTES Important All Acrylic Air Massage baths receive a thorough water test and are carefully inspected and packed for shipment You should check yo
2. 9 0 1st press speed will vary gradually The system will stop automatically after 20 minutes Advanced function An automatic drying cycle will start 20 minutes after the blower is turned off 2nd press system turns off and on alternately 3rd press returns to maximum speed Air Massage Deluxe and Whirlpool Combination Press this key to start the pump They always start at maximum speed Press this key to stop the pump Press this key to start or stop the TB blower They always start at maximum speed decrease the blower speed until k desired level Advanced function ist press speed will vary gradually from maximum to minimum and back to maximum 2nd press system turns off and on alternately 3rd press returns to maximum speed 099 900 Press and hold this key to increase or The system will stop automatically after 20 minutes An automatic drying cycle will start 20 minutes after the blower is turned off OPERATING INSTRUCTIONS continued IN LINE BATH HEATER Optional INTRODUCTION Your AquaHeat Whirlpool Bath Heater utilizes Smart Technology to offer you years of bathing pleasure The advanced electronic design provides trouble free operation and precise control of water temperature There are no adjustments necessary after the whirlpool is filled with hot water the advanced AquaHeat Whirlpool Bath Heater will maintain 104 F water temperature To cool
3. v rifiez le GFCl en appuyant sur le bouton d essai TEST La pompe et le chauffe bain ne devraient pas fonctionner Pour activer de nouveau appuyez sur le bouton de r activation RESET Si le GFCI ne fonctionne pas comme d crit ci dessus le courant de mise terre est pr sent NE PAS op rer la pompe et ou le chauffe bain avant d avoir rem dier la situation Sp cifications 1 5 kW En ligne G VERT W BLANC e 115 volts 20 amp e Interrupteur vide B NOIR CONNEXION LECTRIQUE Branchement Circuit 20A 115V TEST GFCI COURANT NOIR MASSE VERT COMB BLANC Pe ai is LES JETS CD KT DE LA SUCCION 6 INSTALLATION VERSION IN LIGNE DE LA SUCCION NLINE FROM SUCTION VERSION INSTRUCTIONS D UTILISATION suite IMPORTANTES INSTRUCTIONS DE SECURITE AVERTISSEMENT Pour l utilisation de cette unit des pr cautions de base devraient toujours tre observ es incluant ce qui suit 1 LISEZ ATTENTIVEMENT ET OBSERVEZ TOUTES LES INSTRUCTIONS 2 DANGER Pour r duire le risque de noyade ne permettez pas aux enfants d utiliser le bain tourbillon sans la supervision par un adulte en tout temps 3 Utilisez ce chauffe bain pour son usage exclusif seulement tel que d crit dans ce manuel Ne pas modifier le chauffe bain Des chocs lectriques pourraient se produire 4 Ne
4. Power dishwashing detergent To save water you can add the detergent to the tub after use before draining e Run the pump and jets for 10 minutes Drain the tub Refill the tub with fresh warm water to a level above the jets e Runthe pump and jets for 5 minutes e Drain the tub Acrylic Surface The acrylic sheet which forms the surface of your bathtub provides one of the most durable surfaces found in the modern bathroom Keep it bright and smooth with mild liquid household detergent soap and water or foaming cleansers NEVER USE aromatic solvents abrasive cleaners scouring compounds or pads strong liquid cleansers or other material that could damage or dull the surface of the bath We recommend the periodic use of Mirogloss Acrylic and Fiberglass polish to preserve the appearance of your bath Mirogloss Acrylic and Fiberglass polish is available from your dealer Restoring Surface Gloss Restore surface gloss by applying a very fine rubbing compound and polishing the surface by hand or with a power buffer Finish with an application of Mirogloss ora good quality automotive wax Minor Repairs to Surface Remove minor scratches and scuffs as follows First wet sand the area with 600 grit wet sandpaper until the surface is smooth Then restore the gloss as described under RESTORING SURFACE GLOSS Special Finishes on Fittings DO NOT USE powders pads or liquids that contain abrasives Many house
5. SERVICE 110V 15 A NN BE GFCI Viv DE SERVICE 110V 15A NN GFCI p A SOUFFLERIE RACCORDS LECTRIQUES Massage Th rapeutique L installation doit se conformer aux codes locaux de s curit lectrique Seules les exigences g n rales sont mentionn es ci dessous Elles ne couvrent pas toutes les situations ni tous les d tails Un circuit s par de 15 A 115 V est requis prot g par une prise avec disjoncteur de fuite la terre de classe A d une intensit de 15 A Le c ble venant du coffret de branchement devrait comporter deux conducteurs plus une mise la terre Un conducteur n 14 est suffisant pour les distances allant jusqu 100 pi 30 m Pour l air Pour le massage a rien la connexion lectrique est une classe standard un GFCI le r ceptacle de NEMA Certains codes locaux peuvent exiger un sectionneur Celui ci peut tre install dans le mur ou pr s du moteur dans le compartiment de service S il est install au mur il doit se situer au moins 1 5 m 5 pi du bain de sorte que la personne dans le bain ne puise pas l atteindre S il est install dans le compartiment de service il devrait tre fix sur un montant et non pas directement sous le bain Le sectionneur peut tre un interrupteur mural normal tant que son intensit nominale est au moins aussi lev e que l intensit de protection indiqu e ci dessus 0 TOURBILLON PANNEAU DE CONTACT LECTRONIQUE OOO
6. a L insensibilit la chaleur b Le manque de reconna tre la n cessit de sortir du bain c L inconscience d un risque en cours d Dommage au foetus chez les femmes enceintes e L impossibilit physique de sortir du bain f L vanouissement qui r sulterait en un danger de noyade AVERTISSEMENT L usage de l alcool de la drogue ou des m dicaments peut augmenter de mani re significative le risque de l hypothermie fatale DIRECTIVES D ENTRETIEN Bain th rapeutique Le cycle de s chage de 30 secondes apr s que le bain ait t vid est important et se d clenchera automatiquement apr s le bain th rapeutique Sile bain a t utilis simplement comme baignoire ordinaire ou que le mod le combin a t utilis uniquement comme hydromasseur le bain th rapeutique doit tre mis en marche manuellement pendant 30 secondes apr s qu on ait vid le bain Accessoiries d aspiration pour Il hydromassage Dans le syst me d hydromassage du mod le combin la grille d aspiration est celle illustr e la illustration 8 Si l installation n cessite le nettoyage d viser les vis de l cran de la couverture d aspiration Retirer le couvercle et enlevez toute accumulation de charpie ou d autres mati res Pour remettre le couvercle assurez vous que les vis sont a la bonne place Mettre les vis en place et bien serr es pour s assurer qu il n y a pas d cart entre les parois de la cuve et le couvercle d aspiration CRE
7. arr t complet du Combinaison de baignoire remous et de massage par bulles d air Appuyez sur cette touche pour d marrer la pompe Apppuyez sur cette touche pour arr ter la pompe 9 Appuyez sur cette touche pour d marrer ou arr ter le souffleur D marre toujours la vitesse maximum a Appuyez sur cette touche et maintenir vitesse d sir e Fonction avanc e 1 re pression la vitesse varie graduellement du maximum au minimum et retourne au maximum 2e pression le syst me arr te et red marre de fa on alternative 3e pression retourne la vitesse maximum souffleur ORS pour augmenter ou diminuer a la Le syst me arr te automatiquement apr s 20 minutes de fonctionnement Un cycle de s chage d une minute d marre 20 minutes apr s l arr t complet du INSTRUCTIONS D UTILISATION suite CHAUFFE BAIN EN LIGNE Options INTRODUCTION Votre chauffe bain tourbillon AquaHest utilise une technologie intelligente pour vous offrir de nombreuses ann es de satisfaction Sa conception lectronique de haute technologie offre une utilisation s re et sans probl me avec un contr le pr cis de la temp rature de l eau Aucun r glage n est requis quand le bain tourbillon est rempli l eau chaude alors que le dispositif de chauffe bain tourbillon AquaHeat de haute technologie conservera la temp rature de l eau 104 F Pour refroidir l eau ajoutez si
8. as the ampere rating is at least as great as the ampere protection rating noted above B2 110V POWER SUPPLY 1 GREEN GROUND B1 110V POWER SUPPLY 1 BLACK 1 WHITE NEUTRAL 1 GREEN GROUND ELECTRONIC TOUCH PAD CONTROL COMBINATION CONTROL BOX JET AIR B1 110V POWER SUPPLY 1 BLACK 1 WHITE NEUTRAL 1 GREEN GROUND B2 110V POWER SUPPLY 1 BLACK 1 WHITE NEUTRAL 1 GREEN GROUND Figure 6 Air Massage Whirlpool Combination Connections Air Massage Whirlpool Combination The air massage blower and the whirlpool pump each require a 15A 115V circuit that is 2 separate lines from the service box with Class A GFCI protection The cable from the service box is to be 14 2 wire which is satisfactory for distances up to 100 ft 30 m If the local codes require a disconnect switch it must be a duplex switch installed in the service compartment mounted to a stud and not directly to the tub ELECTRONIC CONTROL AIR MASSAGE AND COMBINATION The deck mounted touch pad control on the Air Massage and Combination model is connected to two pin plugs made atthe factory Check underneath the deck that the pin plugs are connected accordingly OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 WARNING RISK OF ACCIDENTAL INJURY OR DROWNING CHILDREN SHOULD NOT USE MASSAGE BATHTUB WITHOU
9. peau pourraient conna tre le soi disant effet a rien froid qui est provoqu par la sensation de bulles d air courant le long de la peau mouill e et fournissant au baigneur avec une sensation frissonnant D placez juste votre corps l g rement loin du jet le plus proche NOTA L l ment chauffant n est pas con u pour chauffer l eau du bain mais pour pr chauffer l air propuls la temp rature du corps 36 37 C 27 98 FE Apr s 5 minute Du temps dirig l air laisse le r servoir de t l phone 40 C 104 F et alors qu il atteint l orifice en jais il est 36 37 C 97 98 F Le cycle de s chage 1 La commande lectronique de votre syst me est programm e pour que 20 minutes apr s l arr t du syst me un cycle de s chage se d clenche automatiquement Ce cycle souffle de l air chaud dans la tuyauterie pendant 30 secondes afin de s cher les t tes de buse Ne pas interrompre le cycle de s chage Si le cycle d marre et est stopp le programme recommencera du d but et un nouveau cycle de s chage d butera 20 minutes plus tard SYSTEME DU BAIN THERAPEUTIQUE Soufflerie Tube a air flexible principal et collets Ensemble du clapet de retenue et du collecteur Tubes des buses a air Corps de buse A Air de buse B Rondelle en n opr ne C Code en L Panneau de contact lectronique Cable du planneau de contact Boite de controle Le cable de bo te de
10. the water simply add cold water as desired NOTE The whirlpool must be running for the Heater to function It is controlled by a vacuum switch Specifications High Limit Protection B BLACK 1 5kw nline In the event the water temperature exceeds 114 F the heater G GREEN 115 Volt 20 Amp will automatically shut off To reset wait until the water W WHITE V itch temperature drops below 104 F then remove power from Vacuum swe the heater by resetting the circuit breaker at the main electrical panel If the High Limit trips frequently contact a qualified service technician Vacuum Switch In the event the pump is not running or if there is not ELECTRICAL CONNECTION sufficient flow the heater will not turn ON To correct contact Branch a qualified service technician Circuit HOT BLACK 20A 115V GND GREEN IMPORTANT ELECTRICAL INSTRUCTIONS COM ITE TEST WARNING when using electrical products basic precautions should always be followed including the following e DANGER RISK OF ELECTRIC SHOCK Connect vy only to a circuit protected by a ground fault circuit interrupter GFCI V oe Use copper conductors only TO JETS Grounding is required Make certain the Heater N and Pump are properly grounded and the pump is BONDED as required FROM Cc The heater must be installed by a qualified SUCTION Q NG electrician in accor
11. ER VA a Illustration 8 I APPAREILLAGE DE RETOUR DE SUCCION R RA gt unene ee K en We Essayage de succion mural aN Ecran de couverture de succion DIRECTIVES ENTRETIEN suite Nettoyer et purger Mise en garde Les tuyaux internes de votre baignoire a remous doivent tre nettoy s r guli rement pour r duire l accumulation de salet d cume ou toute autre accumulation Ce nettoyage doit tre effectu m me si vous utilisez la baignoire sans les jets Utilisez la proc dure suivante pour nettoyer et purger la baignoire au moins une fois par semaine si la baignoire est utilis e chaque jour ou pour la nettoyer tous les trois jours si vous ne l utilisez qu occasionnellement e Remplissez la baignoire d eau ti de jusqu au dessus des jets et ajoutez une tasse de d tergent de lave vaisselle Electrasol Citron Gel Super Nettoyant en Profondeur Pour conomiser l eau vous pouvez ajouter le d tergent l eau de la baignoire apr s l avoir utilis e et avant de la vider e Faites fonctionner la pompe etles jets pendant 10 minutes e Remplissez de nouveau la baignoire d eau ti de fra che jusqu au dessus des jets e Faites fonctionner la pompe etles jets pendant 5 minutes e Videz la baignoire Surface acrylique La feuille d acrylique qui constitue la surface du bain fournit l une des surfaces les plus durables que l on puisse trouver dans les salles de bain modernes L utilisation d un d
12. O DO avin i BO TE DE CONTROLE JET AIR B1 ALIMENTATION DE 110V 1 NOIR 1 BLANC NEUTRE 1 VERT MISE LA TERRE B2 ALIMENTATION DE 110V 1 NOIR 1 BLANC NEUTRE 1 VERT MISE LA TERRE Figure 6 Les Connexions de Combinaison de Massage Tourbillon d air Combinaison de baignoire remous massage par bulles d air Le souffleur de l option de massage par bulles d air et la pompe de la baignoire remous exigent chacun un circuit de 15 A et de 115 V c est dire deux fils distincts du coffret de branchement avec une protection DFT de Cat gorie A Le c ble partant du coffret de branchement doit tre un fil de 14 2 qui est appropri pour les distances allant jusqu 100 pi 30 m Si les codes locaux exigent un interrupteur g n ral il doit s agir d un interrupteur double install dans le compartiment de service fix sur un montant et non directement sur la baignoire COMMANDE LECTRONIQUE TH RAPEUTIQUE ET COMBIN Le panneu de contact lectronique de dont sont munis les mod les Massage th rapeutique et Combin est connect la soufflerie en usine V rifier que le connecteur est bien fix au panneau de contact sous la paroi MASSAGE INSTRUCTIONS D UTILISATION RENSEIGNEMENTS IMPORTANTS SUR LA S CURIT LIRE ET RESPECTER TOUTES LES INSTRUCTIONS CONSERVER CES INSTRUCTIONS 1 AVERTISSEMENT RISQUE DE BLESSURE O DE NOYADE PAR ACCIDENT LES ENFANT
13. S NE DEVRAIENT PAS UTILISER LE BAIN MASSEUR SANS LA SURVEILLANCE D UN ADULTE 2 AVERTISSEMENT RISQUE DE BLESSURE O DE NOYADE PAR ACCIDENT NE PAS UTILISER LE BAIN HYDROMASSEUR SANS LES PROTECTEURS DU DISPOSITIF D ASPIRATION AFIN D VITER LA PRISE DES CHEVEUX OU DU CORPS 3 AVERTISSEMENT POUR VITER TOUTE BLESSURE PRENDRE GARDE EN ENTRANT ET EN SORTANT DU BAIN MASSEUR 4 AVERTISSEMENT RISQUE DE CHOC LECTRIQUE NE LAISSER AUCUN APPAREIL LECTRIQUE TEL QUE S CHOIR LAMPE TELEPHONE RADIO OU T L VISEUR MOINS DE 1 5 M 5 PI DE CE BAIN MASSEUR 5 ATTENTION V RIFIER P RIODIQUEMENT LE DISJONCTEUR DE FUITE LA TERRE QUI PROT GE CET APPAREIL EN SE CONFORMANT AUX INSTRUCTIONS DU FABRICANT 6 AVERTISSEMENT RISQUE D HYPERTHERMIE ET DE NOYADE POSSIBLE UNE TEMP RATURE SUP RIEURE 38 C 100 F PEUT TRE DANGEREUSE POUR LA SANT V RIFIER ET REGLER LA TEMPERATURE DE L EAUAVANT L USAGE SUIVRE TOUTES LES INSTRUCTIONS DE SECURITE DE CE MANUEL UTILISATION SECURITAIRE DU BAIN THERAPEUTIQUE OU HYDROMASSEUR La r action physiologique d une personne un bain th rapeutique ou hydromasseur d pend de l ge de la sant et des ant c dents m dicaux Au d but rester dans le bain pendant une courte p riode seulement jusqu la d termination du niveau de tol rance l eau chaude En cas de migraines de naus es ou d tourdissements sortir imm diatement du bain et prendre une douche froide Con
14. T ADULT SUPERVISION 2 WARNING RISK OF ACCIDENTAL INJURY OR DROWNING DO NOT USE WHIRLPOOL BATHTUB UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT 3 WARNING TOAVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE MASSAGE BATHTUB 4 WARNING RISK OF ELECTRIC SHOCK DO NOT PERMIT ELECTRIC APPLIANCES SUCH AS A HAIR DRYER LAMP TELEPHONE RADIO OR TELEVISION WITHIN 1 5 m 5 ft OF THIS MASSAGE BATHTUB 5 CAUTION TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE PERIODICALLY INACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS 6 WARNING RISK OF HYPERTHERMIAAND POSSIBLE DROWNING WATER TEMPERATURE IN EXCESS OF 38 C 100 F MAY BE INJURIOUS TO YOUR HEALTH CHECK AND ADJUST WATER TEMPERATURE BEFORE USE FOLLOW ALL SAFETY INSTRUCTIONS IN THIS MANUAL SAFE USE OF AN AIR MASSAGE OR WHIRLPOOL Your physiological response to a hot air massage or whirlpool bath depends on your age health and medical history Initially stay in the bath for a short time only until you learn your tolerance for hot water If you develop a headache or become dizzy or nauseous get out at once and cool off under a shower Get medical help if symptoms persist Consult your doctor before you use the air massage or whirlpool for physical therapy of an injury or disorder Don t take an air massage or whirlpool bath without your doctor s consent if you are ill or pregnant or if you suffer from high blood pressure he
15. art disease or other health problems Never take an air massage or whirlpool bath while under the influence of medication drugs or alcohol WARNING DO NOT RUN THE WHIRLPOOL PUMP UNLESS THE BATH IS FILLED WITH WATER TOA LEVEL OF 2 50 mm ABOVE THE WHIRLPOOL FITTINGS Use only small amount of soap or other bath preparation in whirlpool baths otherwise excessive foaming may occur SUCTION DO NOT BLOCK SUCTION INLET SCREEN ON WHIRLPOOL BATHS Water is circulated back to the pump from this location Should the inlet screen become blocked in any way the safety suction will engage and the pump will start cavitating The pump will immediately shut down stopping the flow thus releasing whatever is blocking the screen When the screen is free of blockage the pump will automatically start up and the system is back to normal Under no circumstance is the pump to be used without the screen on the suction return OPERATING CONTROLS The Air Massage andAir Massage Whirlpool Combinations have electronic touch pad controls There is a heating element within the blower that heats the air in the reservoir to 40 C 104 F to prevent the water from cooling too fast It will not under any circumstances reheat or maintain the temperature of the bath water NOTE 20 minutes after the blower is shut off automatically or by the on off control the blower will come on again for 30 seconds to dry the air jets If the tub has not been drained at the t
16. as 1 V rifier que la touche de commande lectronique est correctement reli e 2 V rifier l alimentation lectrique R enclencher le disjoncteur ou remplacer le fusible au besoin 3 V rifier le disjoncteur de fuite la terre R enclencher si d clench 4 Sile syst me a fonctionn pendant un certain temps la protection thermique a pu arr ter le moteur Eteindre le syst me et attendre au moins 30 minutes avant de le r utiliser Le moteur fonctionne mais aucun air ne vient par les buses 1 V rifier que le tube flexible principal reliant le collecteur a la soufflerie est connect correctement Au besoin raccorder et serrer les collets Les sorties d air sont obstru es 1 Si les sorties d air des buses sont bloqu es par du savon ou d autres r sidus remplir le bain d eau ti de frotter les buses doucement avec une vielle brosse a dents puis ACTIVER le syst me et le DESACTIVER plusieurs fois L air propuls semble froid 1 Si le bain est pos contre deux murs ext rieurs il est recommand de fournir une isolation ad quate pour ces murs ext rieurs afin de r duire la perte de chaleur 2 Sur l utilisation initiale quand l eau de bain est tr s chaude l clatement initial d air par les lignes se sentira frais parce que l air est la temp rature plus basse que l eau de bain Le t l phone prend 5 minutes pour atteindre la temp rature op rante optimale 3 Les gens sensibles de
17. ature 3 Skin sensitive people might experience the so called cold air effect which is caused by the sensation of air bubbles running along the wet skin and providing the bather with a shivering sensation Just move your body slightly away from the closest jet to stop the sensation of cold air NOTE Even if the out coming air would be hot enough to burn the skin this shivering effect would still persist NOTE The air heater is not designed to heat the bath water just to preheat the incoming air to body temperature 36 37 C 97 98 Fi After 5 min Of run time the air leaves the blower reservoir at 40 C 104 F and by the time it reaches the jet orifice it s at 36 37 C 97 98 F The drying cycle 1 The electronic control of your system is programmed so that 20 minutes after the system is shut OFF a drying cycle comes on automatically This drying cycle blows hot air for 30 seconds through the piping in order to dry the jet heads Do not interrupt the drying cycle If the cycle comes on and is stopped during the cycle the program will start at the beginning and a new drying cycle will come on 20 minutes later AIR MASSAGE SYSTEM air blower for Air Massage System main air hose and clamp manifold and check valve assembly air jet tubing jet body A single hole air jet B neoprene washer C L elbow touch pad control for Air Massage touch pad cable control box contro
18. contr le connecte avec la soufflerie 10 Alimentation lectrique avec la prise de courant de NEMA O1 B ND CCD 7 SS ONO Pour des pi ces hydromasseur de demander le manuel d installation de l hydromasseur en acrylique Mirolin 5 Jet Body AIR THERAPEUTIQUE ET BAIN HYDROMASSEUR COMBINES 1 Soufflerie 2 Tube a air flexible principal et collets 3 Ensemble du clapet de retenue et du collecteur 4 Tubes des buses a air 5 Corps de buse A Air de buse B Rondelle en n opr ne C Code en L 6 Panneau de contact lectronique 7 Cable du planneau de contact 8 la bo te de contr le le massage d air 9 le c ble de bo te de contr le connecte avec la soufflerie 10 l alimentation les donn es 11 le c ble de coussin de touche le Syst me de Tourbillon 12 la bo te de contr le le Syst me de Tourbillon 13 Le c ble de bo te de contr le connecte avec le pompe moteur de tourbillon 14 l alimentation les donn es le c ble de 15 connecte la bo te de contr le avec le pompe moteur de tourbillon Pour des pi ces hydromasseur de demander le manuel d installation de l hydromasseur en acrylique Mirolin 10 IDENTIFICATION DES PIECES REFERENCE DU DESSIN DU SYSTEME DE BAIN TOURBILLON NO DESCRIPTION NO DESCRIPTION 1 0 Moteur lectrique et pompe 8 0 Raccord union de rupture 1 1 2 po 38mm 1 1 Racc
19. dance with the National Electrical Code and any local codes CAUTION Before operating the pump heater test the GFCI by INSTALLATION IN LINE FROM SUCTION VERSION pressing the TEST button the pump and heater should not operate To resume operation press the RESET button If the GFCI fails to operate as described above there is ground current flowing DO NOT operate the pump heater until this condition is corrected OPERATING INSTRUCTIONS continued IMPORTANT SAFETY INSTRUCTIONS WARNING When using this unit basic precautions should always be followed including the following 1 READ AND FOLLOW ALL INSTRUCTIONS 2 DANGER To reduce the risk of drowning do not permit children to use the whirlpool bath unless they are supervised by an adult at all times 3 Use this heater for its intended use as described in this Manual Do not alter this heater or electrical shock may occur 4 Do not operate the Whirlpool bath or this heater with suction covers removed make certain the suction covers are properly installed before use 5 The heater must be connected to a supply circuit that is protected by a ground fault circuit interrupter GFCI The GFCI should be provided by the installer and should be tested on a routine basis To Test the GFCI press the TEST button the pump and heater should NOT operate Press the RESET button and the pump and heater should resume operation If th
20. e GFCI fails to operate in this manner there is a ground current flowing indicating the possibility of an electrical shock DO NOT use the pump and heater Have the problem corrected by a qualified electrician before using 6 Prolonged immersion in hot water may induce hyperthermia The causes symptoms and effects of hyperthermia may be described as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98 6 F The symptoms of hyperthermia include a An increase in the internal temperature of the body b Dizziness c Fainting The effects of hyperthermia include a Failure to perceive heat b Failure to recognize the need to exit the bath c Unawareness of impending hazard d Fetal damage in pregnant women e Physical inability to exit the bath f Unconsciousness resulting inthe danger of drowning WARNING Use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia 7 To avoid potential damage pregnant or possibly pregnant women should consult a physician before using the whirlpool Water temperature in excess off 100 F is not recommended 8 The bath water temperature should not exceed 104 F Lower temperatures are recommended for extended use 10 15 minutes and are definitely recommended for younger children MAINTENANCE INSTRUCTIONS Air Massage The 30 second drying cycle after the tub is drain
21. ed is important and is automatic after the air massage If the tub was used as a regular bath or the combination model was used only as a whirlpool the air massage must be turned on manually for 30 seconds after the tub is emptied Whirlpool Suction Fittings On the combination whirlpool system the suction screen is the one shown in Figure 8 Should the fitting require cleaning remove the screw from the suction cover screen Pull the cover off and remove any lint or other material When replacing the cover make sure that the screw registers Put the screw back in place and tighten to ensure there is no gap between the tub wall and suction cover _ i CA FES Pd Se A o j A j ee oY ey a dE al 2 Q ESC JH SUCTION WALL FITTING oO 7 SUCTION COVER SCREEN Figure 8 SUCTION RETURN FITTING MAINTENANCE INSTRUCTIONS continued Clean and Purge Warning The internal piping of your whirlpool must be cleaned regularly in order to reduce build up of dirt scum and the like This must be done even if you only use the tub for bathing or soaking and you do not use the jets Use the following clean and purge procedure atleast every week if the tub is used daily or every third use if the use is intermittent or occasional e With the tub filled with bathing temperature water to above the level of the jets add 1 cup of Electrasol Lemon Scented Gel Advanced Cleaning
22. el onto lower flange and press into place against the velcro pads Figure 1 Removable Centre Panel REMOVABLE PANEL VELCRO CLIP Ei APRON FRAME f Ll Copyright 2010 Mirolin Ind The Copyright includes all content on the document INSTALLATION INSTRUCTIONS continued MODELS WITH INTEGRAL APRON Plastic cap Removable panel fastened with screws This instruction applies to the following models only PHOENIX SERIES VIC 53 L R TUCSON SERIES BA 604T L R BAS L R TS 5 L R SYDNEY L R PT520 L R ADORA L R PT516 L R KD 53 L R To remove the panel first expose the screws by removing all the 5 plastic caps Use a flat screwdriver gently to avoid scratching the acrylic path oe Figure 2 Integral apron with removable panel fastened with screws Figure 3 Figure 4 shows the exposed screw fastened on the acrylic apron To remove the panel loosen the screws by using a Phillip s screwdriver Figure 5 Note Plastic caps are color enhanced and for illustration purposes only Plastic caps are color matched based on the color of Figure 3 Unplug the plastic caps the acrylic bathtub RE Cerne MT nile eee Cae ER ESE Figure 4 Exposed screw on the integral apron Figure 5 Remove the screw with a Phillip s scr
23. eur combines DIRECTIVES D INSTALLATION ET MODE DE FONCTIONNEMENT LISEZ TOUTES LES INSTRUCTIONS SOIGNEUSEMENT AVANT LE FAIT DE COMMENCER L INSTALLATION DE VOTRE MASSAGE AERIEN LE BAIN DE COMBINAISON INSCRIRE LE NUMERO DE SERIE DU BAIN THERAPEUTIQUE ET CONSERVER CE MANUEL POUR REFERENCE ULTERIEURE NOTA Utiliser ces instructions conjointement aux instructions d installation des BAINS EN ACRYLIQUE AVERTISSEMENT lors de l utilisation de produits lectriques respecter les pr cautions l mentaires suivantes 1 DANGER RISQUE DE CHOC ELECTRIQUE Relier seulement ce syst me a un interrupteur de d faut a la terre 2 Une mise la terre est n cessaire Une borne de mise la terre l appareil est fournie dans le compartiment de c blage Pour r duire le risque de choc lectrique cette borne doit tre raccord e une mise a la terre fournie dans le panneau d approvisionnement lectrique l aide d un conducteur dont la dimension quivaut aux conducteurs de circuit alimentant cet appareil 3 INSTALLER CET APPAREIL CONFORM MENT AU CODE ELECTRIQUE CANADIEN PARTIE 1 OU LE CODEAPPROPRIE DANS D AUTRES PAYS 4 L INSTALLATION DEVRAIT PERMETTRE L ACC SS POUR L ENTRETIEN 5 Fournir une ventilation ad quate au moteur afin d viter les d clechements inopportuns du syst me de protection de surcharge thermique REMARQUES CONCERNANT L INSTALLATION Important tous les bains th rapeutiques en ac
24. ewdriver ELECTRICAL AND TESTING ELECTRICAL WARNING FOLLOW ALL ELECTRICAL SAFETY REQUIREMENTS LISTED AT THE BEGINNING OF THE INSTALLATION SECTION OF THIS MANUAL Have a licensed electrician make the electrical installation to ensure that all the minimum requirements of the local electrical safety codes are met NOTE All controllers shall be fastened to an adjacent stud 102 mm 4 above the floor INSTALLATION INSTRUCTIONS continued 1 BLACK 1 WHITE NEUTRAL WHIRLPOOL PUMP BLOWER ELECTRICAL CONNECTIONS Air Massage The installation must conform to the local electrical safety codes The following are general requirements only they do not cover all details or all situations The standard requirement is a separate 15A 115V circuit protected by a Class A GFCl rated for 15A The cable from the service box is to be 2 wires plus a ground 14 conductor is satisfactory for distances up to 100 ft 30 m For air massage electrical connection is a standard class AGFCI NEMAreceptacle Some local codes may require a disconnect switch This can be installed in the wall or near the motor in the service compartment If installed in the wall it must be at least 1 5 m 5 ft away from the tub so that a person in the tub cannot reach it If installed in the service compartment it should be mounted to a stud and not directly under tub The switch may be a standard wall switch as long
25. hold cleansers including detergents for automatic dishwashers are abrasive and would damage the plated or coloured surfaces as well as the finish of the acrylic bath TROUBLESHOOTING Blower fails to operate 1 Verify that electronic touch control is connected properly 2 Check electric power supply Reset circuit breaker or replace fuse if necessary 3 Check ground fault circuit interrupter Reset if tripped 4 If he system has been functioning for sometime it is possible that the thermal protection has shut off the motor Switch off the system and wait for at least 30 minutes before using it again Motor runs but no air comes through the jets 1 Verify that the main air hose from the manifold to blower is properly connected If necessary reconnect and tighten clamps Air outlets of jet heads are obstructed 1 If the air outlets of a jet head are obstructed by soap or other residues fill tub with warm water brush the jets gently with an old toothbrush then switch system ON and OFF several times Blowing air seems to be cool 1 If your tub is installed against two outside walls it is recommended to ensure adequate insulation for these outside walls to minimize heat loss 2 Upon initial use when the bath water is very hot the initial burst of air through the lines will feel cool because the air is at lower temperature than the bath water The blower takes 5 minutes to reach optimum operating temper
26. ime it will be necessary to run the blower manually for 30 seconds to dry the jets after the tub is drained OPERATING INSTRUCTIONS continued Whirlpool Fittings Use a finger to swivel the whirlpool jet to give the direction of flow required Do not plug the whirlpool fittings while the pump is running The flow of water can also be increased by turning the jet face plate clockwise and decreased by turning counterclockwise Refer to Figure 7 Caution The whirlpool jets can be misadjusted to throw a stream of water out of the tub onto the floor Drain the Bath Check that the pump is not running Drain the whirlpool bath after each use It is not a spa that can retain its water for repeated use through continuous filtration heating and chemical treatment Motor Protection The blower and pump motors are equipped with a built in thermal overload protector to shut off the motor in the event the temperature becomes excessive as a result of mechanical or electrical problems such as low voltage poor ventilation overload lines etc The motor will restart automatically as it cools down FIGURE 7 ADJUSTABLE FLOW WHIRLPOOL JET ELECTRONIC TOUCH PAD CONTROL Air Massage Deluxe Press this key to start or stop the blower They always start at maximum speed Press and hold this key to increase or decrease the blower speed until desired level from maximum to minimum and back to maximum
27. ion 4 monte la vis expos e et toujours fix e sur la jupe en acrylique Pour enlever le panneau d visser les vis l aide d un tournevis t te toil e Illustration 5 Note Les capuchons en plastique sont de couleur vive pour fins d illustration seulement La couleur des capuchons correspond a celle de la baignoire en acrylique ae o o tO ee ee Illustration 4 Vis expos es sur la jupe int gr e Capuchon en plastique Illustration 2 Jupe int gr e avec panneau escamotable fix e l aide de vis Illustration 3 Enlever les capuchons en plastique Illustration 5 Enlever la vis l aide d un tournevis t te toil e LECTRICIT ET ESSAI LECTRIQUE AVERTISSEMENT LECTRIQUE SUIVEZ TOUTES LES EXIGENCES DE S CURIT LECTRIQUES NUM R ES AU DEBUT DE LA SECTION D INSTALLATION DE CE MANUEL Faites faire un lectricien agr l installation lectrique pour garantir que tous les besoins minimaux des codes de s curit lectriques locaux sont satisfaits NOTEZ Tous les contr leurs seront attach s un clou adjacent 102 millim tres 4 au dessus de l tage POMPE DE LA BAIGNOIRE INSTRUCTIONS D INSTALLATION suite B1 ALIMENTATION DE 110V 1 NOIR 1 BLANC NEUTRE 1 VERT MISE LA TERRE B2 ALIMENTATION DE 110V 1 NOIR 1 BLANC NEUTRE 1 VERT MISE LA TERRE REMOUS DU PANNEAU DE DE
28. ix au tablier de l une des mani res suivantes Les bandes d emboitement de tissu velcro le long du sommet avec les trombones en plastique sur le fond Illustration 1 Vis Illustration 2 Dans l un ou l autre des cas pour retirer le panneau tirez le vers vous la section inf rieure Pour replacer le panneau quip de bandes de mat riel d accouplement aux sections sup rieure et inf rieure alignez le panneau et appuyez fermement sur chacune des deux bandes pour le remettre en place Illustration 1 PANNEAU CENTRAL AMOVIBLE PANNEAU AMOVIBLE VELCRO IAGRAFE A CADRE DU TABLIER f L Copyright 2010 Mirolin Ind Le Copyright comprend tout le contenu de ce document INSTRUCTIONS D INSTALLATION suite MODELES AVEC JUPE INTEGREE Panneau escamotable fix l aide de vis Ces directives ne s appliquent qu aux mod les suivants S RIES DES PHOENIX KD 53 L R S RIES DES TUCSON TS 5 L R BA 604T L R BAS L R SYDNEY L R VIC 53 L R ADORA L R PT520 L R PT516L R Pour enlever le panneau exposer d abord les vis en enlevant les cinq caouchons en plastique Pour ce faire utiliser un tournevis t te plate en prenant soin de ne pas rayer la baignoire en acrylique Illustration 3 Lillustrat
29. k valve 4 2 Suction drain body Suction flange 11 0 Clamp 4 3 Drain face plate Suction cover screen 12 0 Air manifold 4 4 Screw 13 0 T connector 5 0 Air line flex pipe 3 8 10 mm 14 0 Water line flex pipe 1 25 mm 6 1 Jet body 15 0 Suction flex pipe 3 8 10mm 6 2 Wall fitting 16 0 V Fitting 6 3 Face plate 17 0 Back Jet Assembly 7 1 Foot jet body 7 2 Foot jet gasket 7 3 Foot jet wall fitting A eee spa ae 7 4 Foot jet face plate pecify colour or finis TYPICAL WHIRLPOOL SYSTEM WITHOUT BACK JETS 10 ae WHIRLPOOL SYSTEM WITH BACK JETS HAS ADDITION OF BACK JET ASSEMBLY 4 PORT AIR MANIFOLD AND V FITTINGS S 12 4P i 7 ort Manifold Back Jet is 1 Assembly P f S V Fitting Back Jet Body 17 1 Gasket 17 2 Face Plate 17 3 11 NOTES We want you to be completely satisfied with our products and service If you have any comments or suggestions please call 1 800 MIROLIN toll free lt gt p D Customer Service 416 231 5790 p WY M ro 60 Shorncliffe Rd Toronto Ontario M8Z 5K1 1 800 MIROLIN 647 6546 Telephone 416 231 9030 Fax 416 231 0929 Fax Canada 1 800 463 2236 c US www mirolin com Email info mirolin com 84 084 The company reserves the right to change models and specifications without notice 27 March 2013 12 Y Mirolin DE LUXE JETAIR AIR THERAPEUTIQUE Air th rapeutique et bain hydromass
30. l box cable connects with the blower 10 power supply with NEMA plug O1 amp ND CCD 7 SS OOND For whirlpool parts request Mirolin an Acrylic Whirlpool Installation Manual 5 Jet Body tes Dake AIR MASSAGE SYSTEM amp WHIRLPOOL COMBINATION 1 air blower for both Air Massage and Combination units 2 main air hose and clamps 3 manifold and check valve assembly 4 air jet tubing 5 jet body A single hole air jet B neoprene washer C L elbow 6 touch pad control for Air Massage and Whirlpool Combination 7 touch pad cable Air Massage 8 control box Air Massage 9 control box cable connects with the blower 10 power supply input 11 touch pad cable Whirlpool System 12 control box Whirlpool System 13 control box cable connects with the whirlpool pump motor 14 power supply input 15 cable connects control box with the whirlpool pump motor For whirlpool parts request Mirolin an Acrylic Whirlpool Installation Manual 10 PART IDENTIFICATION REFERENCE WHIRLPOOL SYSTEM DRAWING KEY DESCRIPTION KEY DESCRIPTION 1 0 Electrical motor amp pump 8 0 1 1 2 38mm Breaking Union 1 1 Pump union 9 1 Air switch on off for pump 2 0 1 1 2 38 mm Suction pipe 9 2 Air switch gasket 3 0 1 1 2 38 mm Pressure union 9 3 Air switch PVC nut 4 1 Suction elbow 90 deg 1 4 38 mm 10 0 Air chec
31. mplement de l eau froide au besoin Protection de limite de temp rature Dans l ventualit o la temp rature exc derait 104 F le chauffe bain s teindra automatiquement Pour le r gler de nouveau attendez jusqu au moment o la temp rature descend sous 104 F et interrompez le courant au chauffe bain en r glant de nouveau l interrupteur du circuit sur le panneau lectrique principal S il y a interruption fr quente de limite haute consultez un lectricien qualifi Interrupteur vide Dans l ventualit ou la pompe ne fonctionne pas ou ne fournit pas le d bit suffisant le chauffe bain ne sera pas activ Pour y rem dier consultez un lectricien qualifi INSTRUCTIONS IMPORTANTES POUR L ELECTRICITE AVERTISSEMENT Pour l utilisation des produits lectriques des pr cautions de base devraient toujours tre observ es incluant ce qui suit e DANGER RISQUE DE CHOC LECTRIQUE Branchez seulement sur un circuit prot g par un interrupteur de mise terre du circuit GFCI e Utilisez uniquement que des conducteurs en cuivre e La mise terre est requise Assurez vous que le chauffe bain et la pompe sont mis terre ad quatement et que la pompe est METALLISEE tel que requis e Le chauffe bain doit tre install par un lectricien qualifi selon les normes du Code National de l Electricit et selon tous les standards locaux AVERTISSEMENT Avant d utiliser la pompe et ou le chauffe bain
32. n aucun cas la r gle est de ne jamais utiliser la pompe sans l cran sur le retour d aspiration COMMANDES DE FONCTIONNEMENT Le mod le Bain th rapeutique et le mod le combin Bain th rapeutique et hydromasseur sont munis de commandes panneau de contact lectronique L l ment chauffant du bain th rapeutique chauffe 40 C 104 F l air propuls dans le bain pour emp cher l eau de se refroidir trop vite En aucun casil ne r chauffera ni ne gardera la temp rature de l eau du bain NOTA 20 minutes apr s l arr t automatique de la soufflerie ou l interruption volontaire du bain par pression de la touche on off la soufflerie se d clenchera nouveau pendant 30 secondes pour s cher les buses d air Si le bain n a pas t vid ce moment la soufflerie devra tre activ e manuellement pendant 30 secondes pour s cher les buses apr s que le bain ait t vid INSTRUCTIONS D UTILISATION suite Appareil ages du bain tourbillon Utilisez votre doigt pour pivoter le jet du bain tourbillon et obtenir la direction du d bit requis Ne pas bloquer les appareillages du bain tourbillon quand la pompe fonctionne l coulement d eau peut aussi tre augment en tournant la plaque de visage en jais dans le sens des aiguilles d une montre et diminu en tournant dans le sens inverse des aiguilles R f rez la Figure 6 Attention Les jets du bain tourbillon peuvent tre r gl s en erre
33. ord de pompe 9 1 L air allume de la pompe 2 0 Tuyau d aspiration 1 1 2 po 38mm 9 2 Joint de changement a rien 3 0 Raccord de pression 1 1 2 po 38mm 9 3 Changement a rien noix de PVC 4 1 Coude d aspiration de 90 1 72 po 38mm 10 0 Lair entr e contr le valve 4 2 Corps du drain d aspiration bride d aspiration 10 0 Une pince 4 3 Plaque de recouvrement du drain d aspiration 12 0 Collecteur d air 4 4 Vis 13 0 T Connecteur 5 0 Air pipe cha ne de montage flexible 3 8 po 10mm 14 0 Pipe eau en ligne flex 1po 25mm 6 1 Corps du jet 15 0 Pipe d aspiration flexible 3 8 po 10mm 6 2 Fixation au mur 16 0 V Montage 6 3 T ti re 17 0 Assemblage du jet dorsal 7 1 Corps du jet pour pieds 7 2 Gasket 7 3 Fixation au mur NOTE POUR COMMANDER 7 4 T ti re du jet pour pieds Pr cisez la couleur ou le fini SYST ME DE D HYDROMASSAGE TYPIQUE SANS JETS DORSAUX a SYST ME D HYDROMASSAGE AVEC JETS DORSAUX A PLUS DE ASSEMBLAGE DU JET DORSAL COLLECTEUR D AIR DE 4 PORTS ET V MONTAGE de 4 ports Assemblage 17 fe 1 V du jet dorsal 1 Montage Corps du jet g De dorsal 17 1 Gasket 17 2 7 9 T ti re 17 3 12 M gt w Collecteur d air 11 NOTES Nous tenons ce que vous soyez enti rement satisfait de nos produits et services Si vous avez dez commentaires ou des suggestions veuillez composer sans frais le 1 800 MIROLIN lt gt Ser
34. pas utiliser le bain tourbillon ou le chauffe bain avec les couvercles de succion enlev s Assurez vous que les couvercles de succion sont install s de mani re ad quate avant l usage 5 Le chauffe bain doit tre branch sur un circuit lectrique qui est prot g par un interrupteur de mise terre du circuit GFCI Le GFCl devrait tre fourni par l installateur et devrait tre v rifi sur une base routini re Pour v rifier le GFCl appuyez sur le bouton TEST la pompe et le chauffe bain ne devraient pas fonctionner Appuyez sur le bouton RESET et la pompe et le chauffe bain devraient fonctionner de nouveau Si le GFCl ne fonctionne pas de cette fa on il existe un d bit de courant de mise terre indiquant la possibilit d un choc lectrique NE PAS utiliser la pompe et le chauffe bain sous ces conditions Obtenez les services d un lectricien qualifi pour rem dier au probl me avant l usage 6 L immersion prolong e dans l eau chaude pourrait causer l hypothermie Les causes les sympt mes etles effets de l hypothermie seraient d crites comme suit L hypothermie se produit quand la temp rature interne du corps atteint un niveau de plusieurs degr s au dessus de la temp rature normale du corps de 98 6 F Les sympt mes de l hypothermie incluent a Une augmentation de la temp rature interne du corps b tourdissement c vanouissement Les effets de l hypothermie incluent
35. rylique ont subi un essai exhaustif et ont t soigneusement inspect s et emball s pour l exp dition V rifier l appareil En cas de probl mes contacter le marchand avant l installation Prot ger le bain et les raccords contre les dommages et la poussi re en laissant la pellicule protectrice en poly thyl ne en place tant que l installation et tout autre am nagement ne seront pas termin s Attention Ne pas soulever un bain th rapeutique ou un bain hydromasseur par la tuyauterie Manipuler seulement la coque du bain Un acc s doit tre m nag pour permettre l entretien de la soufflerie pompe et des commandes du bain th rapeutique Se r f rer au devis descriptif pour en trouver l emplacement NE PAS d monster la soufflerie ou pompe et ne pas la d placer par rapport sa position d origine Cette localisation assure un bon amorcage un bon drainage et un bon fonctionnement du bain th rapeutique ou du syst me combin Le fait de d placer la soufflerie ou la pompe annulera la garantie NOTA Les raccords pour la tuyauterie la pompe sur les bains combin s se serrent seulement la main V rifier la main qu ils n ont pas t desserr s pendant l exp dition MODELES AVEC TABLIER INCORPORE Les bains th rapeutiques avec tablier incorpor sont munis d un panneau amovible dans le tablier pour permettre l acc s a la soufflerie et la pompe Selon la conception du bain hydromasseur le panneau est f
36. tacter un m decin siles sympt mes persistent Consulter un m decin avant d utiliser un bain th rapeutique ou hydromasseur en vue d une th rapie physique pour une blessure ou un malaise En cas de maladie grossesse tension art rielle maladie de coeur ou autre probl me de sant ne pas prendre de bain th rapeutique ou de bain hydromasseur sans le consentement du m decin Ne jamais prendre de bain th rapeutique ou de bain hydromasseur en tant sous l influence de m dicaments de drogues ou de l alcool AVERTISSEMENT NE PAS ACTIVER LA POMPE DU BAIN HYDROMASSEUR TANT QUE LE BAIN N EST PAS REMPLI AU MOINS 2 PO 50 Hell DESSUS DU NIVEAU DES JETS D EAU L utilisation d eau trop chaude pourrait r duire la durabilit des joints toriques et des joints des buses d airUtiliser uniquement de petites quantit s de savon ou d autre pr parations pour bains hydromasseurs car sinon une mousse excessive risquerait de se produire L aspiration Ne bloquez pas l cran d entr e d aspiration sur les bains remous L eau est distribu e a la pompe a partir de cet emplacement Si la grille d entr e se bloque en aucune fa on l aspiration de s curit s engagera et la pompe d marrera en cavitations La pompe s arr tera imm diatement en arr tant l coulement de l eau en lib rant ce qui bloque l cran Lorsque l cran est libre du blocage le moteur de la pompe d marrera automatiquement et le syst me est de retour la normale E
37. tersif liquide doux de savon et d eau ou de nettoyant moussant permet de la garder brillante et bien lisse NE JAMAIS UTILISER de solvants aromatiques de nettoyants abrasifs de produits ou tampons r curer d agents de nettoyage liquides tr s forts ou un produit qui risquerait d endommager ou de ternir la surface du bain Nous recommandons l utilisation p riodique du poli pur acrylique et fibre de verre Mirogloss pour conserver l apparence du bain Ce produit est en vente dans le commerce Restauration du lustre de la surface Pour redonner du lustre la surface appliquer un compos de frottage tr s fin et polir la surface la main ou l aide d un polisseur lectrique Finir en appliquant Mirogloss ou une cire pour automobile de bonne qualit R parations mineures de la surface Enlever les rayures et les traces de frottement mineures comme suit Frotter d abord la surface humide avec du papier de verre 600 grains jusqu ce que la surface soit lisse Puis restaurer le lustre comme d crit dans RESTAURATION DU LUSTRE DE LA SURFACE Finis sp ciaux des accessoires NE PAS UTILISER de poudres de tampons ni de liquides qui contiennent des agents abrasifs De nombreux nettoyants m nagers y compris les d tersifs pour les lave vaisselles automatiques sont abrasifs et endommageraient les surfaces plaqu es ou color es ainsi que le fini du bain en acrylique GUIDE DE D PANNAGE La soufflerie ne fonctionne p
38. ur et projeter un jet d eau hors du bain et sur le plancher Vidange du bain V rifiez que la pompe ne fonctionne pas Vidangez le bain tourbillon apr s chaque usage Il ne s agit pas d un Spa qui peut retenir son eau pour usage r p t en utilisant une filtration continue le chauffage etle traitement chimique Protection des moteurs Les moteurs du ventilateur et de la pompe sont quip s d un protecteur de surintensit thermique pour arr ter les moteurs en cas de temp rature excessive du moteur r sultant de probl mes m caniques ou lectriques tels que le voltage bas une ventilation inad quate surintensit des fils etc Le moteur d marrera de nouveau automatiquement quand il sera refroidi FIGURE 6 Jet de tourbillon d coulement ajustable COMMANDE DU PAV TACTILE LECTRONIQUE Massage par air de luxe Appuyez sur cette touche pour d marrer ou arr ter le souffleur D marre toujours la vitesse maximum Appuyez sur cette touche et maintenir pour augmenter ou diminuer la vitesse d sir e graduellement du maximum au Q 1 re pression la vitesse varie Le syst me arr te automatiquement apr s 20 minutes de fonctionnement ae Fonction avanc e minimum et retourne au maximum 2e pression le syst me arr te et red marre de fa on alternative 3e pression retourne la vitesse maximum souffleur Un cycle de s chage d une minute d marre 20 minutes apr s l
39. ur unit for any problems Contact your dealer before installation Protect the bathtub and fittings from dirt and damage by leaving the polyethylene protective film in place until installation and other related construction are complete Caution Do not lift an air massage bath or whirlpool by its plumbing Handle it by the bath shell only Access for servicing the Blower Pump and Controls of the air massage bath must be provided Refer to specification drawings for location DO NOT remove or relocate the blower or pump from its factory installed position This position ensures proper priming drainage and performance of the air massage or combination system Relocating the blower or pump will void the warranty NOTE The unions for the piping at the pump on the combination units are only to be hand tightened Check by hand that they have not loosened during shipping MODELS WITH INTEGRAL APRON Air massage baths with an integral apron have a removable panel in the apron for access to the blower and pump Depending on the design of the whirlpool the panel is fastened to the apron by either of the following Strips of interlocking fabric velcro along the top with plastic clips on the bottom Figure 1 Screws Figure 2 In either case to remove panel follow instructions below Panel with strips of interlocking fabric gently pull the panel away starting from the top To replace the panel position the removable pan
40. vice la client le 416 231 5790 S p WY O 60 Shorncliffe Rd Toronto Ontario M8Z 5K1 Canada U 1 800 MIROLIN 647 6546 T l phone 416 231 9030 T l copieur 416 231 0929 T l copieur Canada 1 800 463 2236 c E www mirolin com Courriel info mirolin com 84 084 La soci t se r serve le droit de changer les mod les et les sp cifications sans pr avis 27 Mar 2013 12

Download Pdf Manuals

image

Related Search

Related Contents

Las bombas SP370 – SP450 – SP750 para piscinas pueden ser  12WH [更新済み]  HL675 - Système de transmission d`impulsions / data 500mW    GA Lamborghini Aventador - L` Atelier Abflug  Samsung 256l ar saldētavu apakšā RL29THCTS Lietotāja rokasgrāmata  Sun Storage 2500-M2 Arrays Getting Started Guide  REMstar Homecare OIS2,dom  USER MANUAL  QSC SR-18 User's Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.