1. 613CCB Contemporary Cast Front Black INSTALLATION INSTRUCTIONS CSA approved for use only with Valor Models 534 and 535 Heaters Note This kit must be installed or serviced by a qualified installer service agency or gas supplier These instructions are to be used in conjunction with the main installation instructions for the above listed model WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life The 613CCB Contemporary Cast Front Black may be fitted to any Valor models 534 or 535 heaters either at the time the heater is installed or retrofitted afterwards provided existing wall and hearth finish allow see diagrams The installation of the Contemporary Cast Front has specific mantle clearances and framing dimensions described below which differ from those listed for other trims used with 534 and 535 heaters Refer to the installation manual packed with the heater for all other aspects of installation The 613CCB requires the installation of non combustible material above the heater when fitted to the 535 model heater Heat Duct Backing Plate Assembly 4 Inner Casting t t Fret N Ashpan Kit Content i 35 3 4 1 NOTE Wall finish must be flush or slightly in front of this frame on heater Backing Plate Assembly Inner Casting Fret Ashpan Assembly Overview
2. 31 364 1 2 Max Clearance bot of door to bot of plate 4001086 04 NOTE This kit MUST be installed at finish hearth height MILES INDUSTRIES underside of header Allow for finished hearth height if any or floor Minimum 16 35 4 2 allow extra for rear vent elbows Framing Cavity e Approved for combustible floor under and in front of the appliance e Combustible wall finish may contact the sides of the heater s black frame e Non combustible wall finish may be required above the heater between the header and the backing plate see Wall Finish Detail amp Mantel Clearances diagram Brackets on the rear of the backing plate to limit the bottom height of e the combustible wall finish above the 534 heater or e the non combustible wall finish above the 535 heater Installation Combustible mantel or shelf LH Frame Non combustible material above 535 model only f 36 from floor to bottom of header Angle Support 613 Backing Plate Lower limit of combustible wall finish on 534 31 1 4 from floor 534 535 Black Frame Wall Finish Detail amp Mantel Clearances Mantel 7 7 waze eje pelz Mantel EL 5 5 5 5 5 ne 2 os se ar s fa 1 Install the heater into framed cavity as described in these instructions and com plete the remainder of the installation as p
3. D tails de la finition du mur et d gagement pour D tails de finition du mur et d gagements manteau et tablette pour manteau de chemin e et tablette Profondeur 5 cm 10 cm 15cm 20cm 25cm 30 cm du manteau 2 4 6 8 10 12 Hauteur B du 81cm 89cm 97cm 102 cm 107 cm 112 cm manteau 32 35 38 40 42 44 Les supports a l arri re de la plaque de soutien limitent la hauteur de la base e du mur combustible du dessus du foyer 534 OU e du mur non combustible au dessus du foyer 535 Installation 1 Installez le foyer selon les instructions indiqu es plus haut et compl tez l installation selon les indications du manuel fourni avec le foyer Finissez le mur jusqu au p rim tre de l encadrement noir de chaque c t du foyer et aux supports l arri re de la plaque de soutien Assurez vous que la finition du mur est gale l encadrement noir ou qu elle d passe l g rement l encadrement noir Assurez vous d avoir assez d espace entre le foyer et le sol pour la base du foyer ou la finition du plancher d faut de quoi il ne sera pas possible d installer la plaque de soutien du kit 2 Enlevez le d flecteur de chaleur fourni avec le foyer et remplacez le par celui fourni avec ce kit en utilisant les 3 vis existantes Assurez vous que le d calage du d flecteur est orient vers le haut s MILES 3 Montez la plaque de soutien au fo
4. instructions doivent tre utilis es conjointement avec les instructions d installation des mod les de foyer Valor 534 ou 535 MISE EN GARDE Si les instructions fournies dans le present manuel ne sont pas Suivies a la lettre un feu ou une explosion pourraient resulter et causer des dommages materiels des blessures ou la mort Le kit 613CCB peut tre install avec les foyers Valor 534 ou 535 au moment de l installation du foyer ou a une date ult rieure condition que la finition du mur et la base de foyer le permettent voir les sch mas aux pages suivantes Les d gagements et dimensions d encastrement montr s ci dessous sont sp cifiques l installation de ce kit et sont diff rents de ceux sp cifi s pour les autres devantures list es aux manuels d installation des foyers 534 et 535 Consultez le manuel d installation fourni avec le foyer pour les autres aspects de l installation Lorsque ce kit est utilis avec un foyer 535 le mur au dessus du foyer doit tre fabriqu de mat riau non combustible D tecteur de chaleur Plaque de soutien Cadre int rieur alin T Base chantourn e Garde cendres Contenu du kit 91 cm 35 3 4 D gagement maximal de 1 2 entre le bas de la porte et le bas de la plaque NOTE Ce kit doit tre install au m me niveau que gal au le dessus de la base de foyer NOTE La finition du mur doit tre gale ou d passer l g remen
5. ding the bolts into the slots of the fret brackets on the inner casting Adjust bolts as necessary for a tight fit Hook the ash pan to the fret Adjust top heat baffle by pulling it forward until it lines up with the flange of the top part of the backing plate Tighten the screws Drywall 534 Non combustible 535 31 1 4 from floor 68 mm long Flange Backing Plate Top F Backing Plate Flange 534 535 Black Frame Heat duct must be adjusted to be flush with protuding flange of backing plate 534 535 Engine Heat Duct Backing Plate Left Side Inner Casting 3 yy MULES Repair Parts List Part Number 4001075AZ 4001085AZ 4000966 4 4001089 4000970 4000980 4000972AZ 4000971 AZ 4001206 3 Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www milesfireplaces com Copyright Miles Industries Ltd 2006 CIMILES Valor Devanture de fonte contemporaine 613CCB MANUEL D INSTALLATION Homologu e par la CSA pour utilisation exclusive avec les modeles de foyers Valor 534 et 535 Note Ce kit doit tre installe et entretenu par un installateur qualifie une agence de service certifi e ou un fournisseur de gaz Ces
6. er instructions packed with heater Finish the wall up to the perimeter of the black frame at sides of the heater and to the brackets on the rear of the backing plate at the top Ensure that the wall finish is flush or slightly in front of the black frame Allow for height of finished hearth or floor or steel backing plate will not install 2 Remove the existing top heat baffle supplied with the heater and replace it with the heat baffle supplied with this kit using the same 3 screws Ensure the baffle offsets upwards 2 CIMILES 3 Mount the backing plate to the heater with screws in the 4 slots 2 per side of the plate slide the plate in desired position according to wall finish Tighten the SCrews 4 Fix the hanging brackets to the back side of the Inner Casting as shown Note the left right orientation of the 9 brackets 7 D 5 There are 4 tabs on the inside of the heater s black frame those are intended for mounting other trims These tabs conflict with the installation of the cast front packaged with this kit These 4 tabs must either be cut off or bent back out of the way to allow the In ner Casting to install see diagram Cut or bend back the tabs Cut or bend back the tabs Section View of the 613CCB Kit Right Side View Front of fireplace Hook the Inner Casting to the edge of the backing plate flanges as shown Drop cast iron fret into place by sli
7. s ee ms mm 31 1 4 du plancher Fer d angle de 68 mm de haut Haut de la plaque de soutien gt Rebord de la plaque de soutien agj Encadrement noir Le d flecteur de chaleur 4082987 de la plaque de soutien Foyer 534 535 D flecteur de chaleur C t gauche de la plaque de soutien Cadre int rieur MILES 7 Liste de pieces No de pi ce D flecteur de chaleur 4001075AZ Plaque de soutien 4001085AZ 4000966 4001089 4000970 4000980 4000972AZ Base chantourn e 4000971AZ Quincaillerie 4001206 3 Parce que notre politique vise l am lioration et le d veloppement continus certains d tails de la presente publication peuvent varier Con u et fabriqu par pour Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver C B CANADA V7H 3B1 T l 604 984 3496 T lec 604 984 0246 www milesfireplaces com 2006 Miles Industries Ltd Tous droits r serv s CIIMILES
8. t en saillie l encadrement du foyer Foyer 534 535 D flecteur de chaleur Plaque de soutien LT Cadre int rieur 7 Base chantourn e Garde cendres Concept NOTE Ce kit DOIT tre install a la hauteur du dessus de la base de foyer YIMILES INDUSTRIES 5 A Manteau de 4 p gt chemin e ou tablette T C t gauche de combustible Sal l encastrement Finition du mur pe er Ten ae eae nt Le Poutre de t te Mat riau incombustible requis au dessus du foyer 535 seulement B gt 92 cm 36 entre le sol et le dessous de la poutre de t te Fer d angle Fem 36 du sol au dessous de la poutre de t te Plaque de soutien 613 Limite de la base de la finition combustible pour le foyer 534 79 cm 31 1 4 du plancher Ajoutez la hauteu 41 cm 16 minimum n de la base du 0 cm 35 12 foyer ou de la 7 finition du permettre plus d espace pour I h les coudes pour vacuation arri re piancner Dimensions de l tre e Mat riau combustible permis sous et devant le foyer e Aucun d gagement requis entre la finition du mur combustible et les c t s de l encadrement noir du foyer La finition peut toucher les c t s de l encadrement e Une finition incombustible peut tre exig e imm diatement au dessus du foyer entre la poutre de t te et la plaque de soutien du kit voir le schema
9. yer et vissez la de chaque c t 2 vis par c t dans les fentes des onglets glissez la plaque a la position d sir e selon la finition du mur Serrez les vis gt B 4 Fixez les supports de montage 2 l arri re du cadre 8 int rieur tel qu indiqu Notez qu il y a un support pour la droite et un pour la gauche 6 Accrochez le cadre int rieur aux rebords des onglets de la plaque de soutien tel qu indiqu ci dessous D vissez partiellement les vis l arri re de la base chantourn e accrochez la base aux supports pr vus cet effet au bas du cadre int rieur en ins rant les vis dans les fentes des supports Accrochez le garde cendres sur la base chantourn e 9 Adjustez le d flecteur de chaleur en le tirant jusqu ce quil soit align au rebord de la plaque de soutien Serrez les vis du d flecteur Coupe transversale du kit 613CCB p Panneaud de gypse 534 vue du c t droit Panneau incombustible 535 5 Ily a 4 onglets l int rieur de l encadrement noir du foyer 2 par c t Ces onglets sont utilis s pour accrocher certaines devantures cependant dans ce cas ci ils emp chent l installation du cadre int rieur Pour faciliter l installation du cadre coupez ou repliez vers l int rieur ces 4 onglets tel qu indiqu ci dessous Coupez ou repliez l onglet Coupez ou repliez l onglet doit tre align au rebord Devant du foyer aoe S

Download Pdf Manuals

image

Related Search

Related Contents

Learning OpenCV - Department of Electrical Engineering  Wave User Guide 15.3 版  Samsung Духова шафа BFN1391T Керівництво користувача  operação - Victor Technologies  Realistic 120-1451 Radio User Manual  D-Link DWL-G132 User's Manual  Notice d`utilisation Chargeur COMPACT FC  CONSIGUE LA FOTO DE TU PUZZLE JORNADA  LG 32LY340H 31.51" HD-ready Titanic LED TV  SSV10.4F - Sound Storm Lab  