Home

DGA - Easy Catalogue

image

Contents

1. LS su ti Self f onta ail sed Dic gicode 7 Digicode avec Int gr 2 Range Digicode Gamme Digicode a INSTALLATION MANUAL MANUEL D INSTALLATION CDVI Group Company minium Digicode Self Contained 1 PRODUCT PREVIEW The DGA a self contained keypad under the Digicode brand was engineered to secure your accesses The DGA will compliment any audio or video entry systems to control the operation and locking of your doors and gates Its design and its high resistance to vandalism make it suitable to secure residential as well as industrial sites Its compatibility with all CDVI locking devices gives you the flexibility to set your own personalized system while keeping a high security level I luminated keypad 98 amp Cast aluminium body i 2 relay Surface mount S Free voltage 100 user codes Torxemounting screws 120 2 relay outputs contact 8A 250V 100 user codes 4 to 6 digits m All programming stored in non volatile EEPROM memory 9 1O 9606 1 request to Exit input KL 1 master code Modification of Pin code by the user m Visual sound feedback Keypad Illumination Permanent or tim
2. The output be programmed The timer input H1 if connected allows using the 0 key as a request to enter If the timer contact is open then the 0 digit key is used for the Pin code if the contact is closed then the key is used for the request to enter CONSUMPTION 12V AC in stand by 20 mA when 2 relay outputs activated 80 mA max 24V AC in stand by 10 mA when 2 relay outputs activated 40 mA max RESET MASTER CODE AND DELETE ALL USER CODES 1 Enter the master code twice 12345 default value master code the red LED lights on to confirm entry in programming mode 2 Press to enter in the reset menu the green LED lights on for 1 second press simultaneously on A and B to start the reset the green LED lights during all the reset process wait until it lights off the master code is reset to its factory value 12345 and all the user codes are deleted the keypad is reset to the factory default values the red LED lights on then lights off 1 Turn off the power Short the white and the yellow wires 2 Power on the keypad the green LED lights on wait a few seconds one beep is emitted The green LED lights off Unshort the wires 3 The keypad is reset to the factory default values SETTING CODE LENGTH 1 Enter the master code twice 12345 default value master code the red LED lights on to confirm entry in programming mode 2 Press 4 to program the code length the green LED lig
3. com 5 ninium Digicode Self Contained the green LED lights during 1 second Enter the time in 10th of second 10 for 10 seconds up to 99 for 99 seconds the backlighting dims 10 seconds after the last keypress or switches off after entering a valid code enter 00 for a permanent illumination keys The green LED lights during 1 second 3 Press 1 to program relay 1 output time door release time the green LED lights during 1 second for a timed output enter the time in seconds 01 for 1 second up to 99 for 99 seconds enter 00 for a latched output the green LED lights during 1 second to validate the time 4 Press A2 to program relay 2 output time door release time the green LED lights during 1 second for a timed output enter the time in seconds 01 for 1 second up to 99 for 99 seconds enter 00 for a latched output The green LED lights during 1 second to validate the time 5 Press B to exit from programming mode the red LED lights to confirm exit from programming The red LED flashes 4 times to indicate a data computing error RESET MASTER CODE Short the white and the yellow wires the green LED lights on one beep is emitted wait until the green LED lights off Separate the two wires the master code is reset to the factory default value 123456 in 6 digit code length 12345 in 5 digit code length or 1234 in 4 digit code length CHANGING THE CODE BY THE USER To authorize a user t
4. un automatisme Son design et sa haute r sistance au vandalisme pr dispose le DGA s curiser les acc s des environnements industriels et r sidentiels Compatible avec l ensemble des solutions de verrouillage CDVI il pourra s adapter la configuration de votre choix tout en vous offrant un haut niveau de s curit R tro clair Alliage d aluminium 2 relais Pose en applique Free voltage 100 codes utilisateurs Clavier 12 touches lumineux Montage avec vis Torx Sauvegarde m moire permanente E2PROM Signalisation lumineuse et sonore 100 codes programmables en 4 5 ou 6 termes 120 9 1O 96006 m 2 relais d ouverture 1 contact RT 8A 250V 4 Code ma tre programmable en 4 5 6 termes m bouton poussoir de sortie commandant __ l ouverture Code ma tre usine 12345 et raz des codes m Modification des codes par l utilisateur amp RoHS Signalisation lumineuse et sonore Choix du mode d clairage Test brouillard salin Permanent ou en action Alimentation 164 12 V 24 V AC 12 V 48 V DC Certification CE 2 O 25c naute REST 2 PROGRAMMATION DU CLAVIER VALEURS PAR D FAUT Aucun code Tempo s curit programmation 120 se
5. 0 31 748 09 30 o 5 2 L O 5 9 4 amp fe oN oe fo 227 4 3 v S 2 5 8 D 5 Ea 5 2 0 2 5 9 D CDVI UK Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 TECHNO EM FRANCE Phone 33 0 4 42 96 58 73 33 0 4 42 96 45 77 pr alable
6. 1 Jaune Vert Vert clair Bleu S Violet C2 Gris T2 m Bleu fonc R2 Blanc REMISE ZERO Correspondances Fils de sortie ame CEE TS pee fems cdvi com 16 cdvigroup com Varistance Ce produit est livr avec une varistance Celle ci doit tre mont e directement sur les bornes de la g che ventouse moteur command e par l quipement Si l appareil fonctionne avec plusieurs g ches chacune doit tre quip e de varistance La varistance limite les surtensions provoqu es par le bobinage de la g che effet de self ANUEL D INSTALLATION DGA Digicode avec lectronique int gr e 4 KIT DE MONTAGE 680K Varistance 5 Vis TORX t te frais e 4 10 Cl m le coud e pour vis TORX T20 Vis cruciforme t te frais e M4x30 Cheville plastique S5 Apr s avoir v rifi que le kit de montage est complet vous allez pouvoir proc der l installation finale du produit R unissez le mat riel appropri Perceuse tournevis et suivez les recommandations de montage du DGA A l aide du DGA prenez les marques et percez les 2 trous de fixation for t 5 mm et profondeur minimum 35 mm ainsi que l ouverture pour le passage du c ble lectrique destin au clavier Po
7. ach lock should have a varistor The varistor controls the overload produced by the strike coil back emf INSTALLATION MANUAL DGA Cast aluminium Digicode Self Contained 4 MOUNTING KIT 05D 680K Spanner S5 plastic for Varistor T20 screws DES Once you have made sure that the mounting kit is complete and that you prepared the cables of the DGA keypad then you can proceed and mount the product Make sure that you have all the appropriate tools drill screw drivers and a meter tape and follow the mounting instructions of the DGA keypad Take the marks with the back plate Insert the 2 plastic anchors Then fasten the screw at the buttom of the DGA Drill the 2 mounting mount the back plate of the DGA of the DGA keypad with the Torx holes 5 MM bit and 35 MM depth keypad and screw on the wall with screw using the spanner minimum and the wiring access the M4x30 mounting screws hole Insert the cable of the keypad the wiring access area Place the keypad on the back plate top first and then make sure that it fits all over the back plate cdvi com cdvigroup com 9 Le DGA est un produit de la gamme Digicode avec lectronique int gr e enti rement d di la s curit de vos acc s Il est pr conis en compl ment d un interphone ou d un vid ophone pour contr ler vos portes et portails quip s ou non d
8. condes Tempo clairage 10 secondes Codes de modification par utilisateur Groupe 1 A et B Tempo d ouverture pour les relais 1 seconde Codes de modification par utilisateur Groupe 2 1 et 3 Nombre de termes 5 La led rouge s allume la mise sous tension Code usine 12345 cdvi com 10 cdvigroup com MANUEL D INSTALLATION DGA Digicode avec lectronique int gr e CORRESPONDANCE DES SIGNAUX SONORES 1 bip court 1 bip long 2 bips courts 4 bips courts Mise sous tension Validation d une saisie en programmation et ouverture Entr e ou sortie de programmation Erreur de saisie VVVV TERMES UTILISES ET CODES D OUVERTURES Toutes les touches du clavier sont autoris es pour composer les codes Le code maitre et les codes d ouverture de porte doivent tre compos s de 4 5 ou 6 termes Le code maitre ne peut pas tre utilis comme code d ouverture Les codes 000000 ou 00000 ou 0000 servent a annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte COMMANDE PAR BOUTON POUSSOIR Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 le mode et la temporisation sont programmables Le contact horloge 1 permet l utilisation de la touche 0 comme bouton ext rieur Si le contact horloge est ouvert la touche 0 est utilis e comme un terme habituel Si le contact horloge est ferm la touc
9. ed Operating voltage 12V to 24VAC RoHS 12V to 48VDC Environmental tests Consumption Salt spray 25 to 80 mA TE CE Certification HIGH RESISTANCE VANDALISM 25 70 C 2 PROGRAMMING DEFAULT FACTORY VALUES No code programmed in the keypad Programming mode time 120 seconds Illumination time 10 seconds Sub master code for user to reprogram its Pin code group 1 A Relay output time 1 second Sub master code for user to reprogram its Pin code group 2 1 and 3 Code length 5 digits Red LED lights on when the keypad is powered Master code 12345 cdvi com 2 cdvigroup com INSTALLATION MANUAL DGA Cast aluminium Digicode Self Contained AUDIBLE SIGNAL 1 short beep gt Keypad powered 1 long beep data computing in programming or access granted 2 short beeps Enter or Exit from programming 4 short beeps Data computing error VVV CODE LENGTH All the keypad keys can be used to program a code The master code and the Pin code can be of 4 5 or 6 digits The master code CAN NOT be used as a PIN code User Pin code Codes 000000 00000 and 0000 can only be used to delete a user code To delete a specific User Code replace it by 0000 if code length is 4 digit format or replace it by 00000 if the code is in 5 digit format REQUEST TO EXIT INPUT 1 input activates relay 1
10. ermes des codes la led verte s allume 1 seconde tapez 4 5 ou 6 pour le nombre de termes la led verte s allume 1 seconde pour confirmer la programmation 3 1 Tapez 5 pour changer le code ma tre la led verte s allume 1 seconde tapez les 4 5 ou 6 termes du nouveau code maitre la led verte s allume 1 seconde pour confirmer la programmation 4 Tapez B pour sortir de la programmation la led rouge s teint pour confirmer le retour au mode normal de fonctionnement 4 clignotements de la led rouge indique une erreur de saisie Code ma tre ou code utilisateur 12369 Passage 4 termes Tapez 2369 Passage 6 termes Tapez 012369 Il est conseill de programmer les codes en 6 termes puis de modifier le nombre de termes PROGRAMMATION DU CODE MA TRE 1 Tapez 2 fois le code ma tre pour la premi re utilisation le code maitre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation 2 Tapez AS la led verte s allume 1 seconde tapez les 4 5 ou 6 termes du nouveau code maitre la led verte s allume 1s pour confirmer la programmation 3 Tapez B pour sortir de la programmation la led rouge s teint pour confirmer le retour au mode normal de fonctionnement PROGRAMMATION DES CODES Groupe 1 Du rang 00 au rang 59 relais 1 Groupe 2 Du rang 60 au rang 99 relais 2 1 Tapez 2 fois le code maitre pour la premi re utilisation
11. he 0 est utilis e pour l ouverture libre CONSOMMATION SANS LES ELEMENTS DE COMMANDE En 12V Au repos 20 mA avec les 2 relais command s 80 mA maximum En 24V Au repos 10 mA avec les 2 relais command s 40 mA maximum REMISE A ZERO DE LA MEMOIRE 1 Tapez 2 fois le code maitre pour la premi re utilisation le code ma tre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation 2 Tapez 6 la led verte s allume 1 seconde tapez et B pour valider la remise z ro les led verte s allume attendre qu elles s teignent Le code maitre est de nouveau 12345 et tous les codes sont effac s Le clavier est r initialis la led rouge reste allum e puis s teint Le clavier est sorti de programmation et les valeurs par d faut sont r tablies 1 Coupez l alimentation reliez les fils blanc et jaune 2 R tablir l alimentation la led verte s allume attendre quelques secondes un bip est mis la led verte s teint s parez les fils 3 Le code ma tre est de nouveau 12345 et tous les codes sont effac s les valeurs par d faut sont r tablies cdvi com cdvigroup com 11 avec lectronique int gr e PROGRAMMATION DU NOMBRE DE TERMES 1 Tapez 2 fois le code maitre pour la premi re utilisation le code ma tre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation 2 Tapez A4 pour la saisie du nombre de t
12. he red LED lights on to confirm entry in programming mode pour programmer des codes MASTER CODE MASTER CODE RED LED LIGHTS ON 2 To add a user code enter the user number from 00 to 99 If the user number is free the green LED lights during 1 second enter the 4 5 or 6 digit code If the user number is already programmed the red LED flashes 4 times To modify the user code enter a 4 5 or 6 digit code To cancel the user code enter 000000 or 00000 or 0000 code cdvi com 4 cdvigroup com INSTALLATION MANUAL DGA Cast aluminium Digicode Self Contained Be SSS SESS EE SSeS Se The green LED lights on duri ng 1 second to confirm programming If the user code is already programmed or is identical to the master code then the red LED flashes 4 times to indicates a data computing error Note that the codes 000000 or 00000 or 0000 are strictly used to deleted a user code only 3 Press B to exit from programming mode The red LED lights off to confirm exit from programming USER CODE LIST olojo WIN IH N B m gt Lo m N Ha 2 N N SETTING ILLUMINATION AND OUTPUT TIME 1 Enter the master code twice 12345 default value master code the red LED lights on to confirm entry in programming mode 2 Press AO to program the key in keypad time and the illumination time cdvi com cdvigroup
13. hts on during 1 second press 4 5 or 6 to enter the code length cdvigroup com luminium Digicode Self Contained the green LED lights on during 1 second to confirm programming of the code length 3 Enter 5 to modify the master code the green LED lights on during 1 second enter the new 4 or 5 or 6 digit master code the green LED lights on during 1 second to confirm programming of the new master code 4 Press B to exit from programming mode the red LED lights off to confirm exit from programming The red LED flashes 4 times to indicate a data computing error Master code or user code 12369 When changing to 4 digit code enter 2369 When changing to 6 digit code enter 012369 It is recommended to program the codes in 6 digits and then modify the code length CHANGING THE MASTER CODE 1 Enter the master code twice 12345 default value master code the red LED lights to confirm entry in programming mode 2 Press A5 the green LED lights on during 1 second enter the new master code according to the code length set up the green LED lights on during 1 second to confirm programming 3 Press B to exit from programming mode The red LED lights off to confirm exit from programming ADDING USER CODES Group 1 from user number 00 to user number 59 relay 1 Group 2 from user number 60 to user number 99 relay 2 1 Enter the master code twice 12345 default master code t
14. le code maitre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation Pour programmer des codes CODE MA TRE CODE LED ROUGE cdvi com 12 cdvigroup com MANUEL D INSTALLATION DGA Digicode avec lectronique int gr e 2 Tapez le n du rang a programmer de 00 99 si le rang est libre la led verte s allume 15 tapez les 4 5 ou 6 termes du code si le rang est occup la led rouge clignote 4 fois tapez les 4 5 6 termes du code ou tapez 000000 ou 00000 ou 0000 pour annuler le code existant la led verte s allume 1seconde pour confirmer la programmation Si le code entr correspond un code existant s il est identique code maitre la led rouge clignote 4 fois pour indiquer une erreur Les codes 000000 ou 00000 ou 0000 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte 3 Tapez B pour sortir de la programmation la led rouge s teint pour confirmer le retour au mode normal de fonctionnement CODES DE COMMANDE D OUVERTURE olojo BEIE N a m N BE aE E 1 _ m me NIO ee N NN Re cdvigroup com 13 PROGRAMMATION DES TEMPORISATIONS 1 Tape
15. nd to confirm programming of the sub master 4 Press B to exit from programming the red LED lights off to confirm exit from programming AUDIBLE SIGNAL The audible signal is enabled in programming mode and when the relay is energised after a valid code To enable the audible feedback on a key press 1 Enter the master code twice 12345 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press twice One beep is emitted Press 0 to disable the audible signal during a keypress Press 1 to enable the audible signal during a keypress One beep confirms the modification 3 Press B to exit from programming 2 beeps are emitted to confirm exit from programming mode cdvi com cdvigroup com 7 INPUT VOLTAGE 230 V 12V 24VAC R 12V 48VDC ed Pink C1 530 INPUT VOLTAGE ELECTROMAGNET Locking devices Brown NC Orange NO Yellow 51 Dark green O 0 PI H Light green Blue 2 Dark blue NC White RESET Description foeren _ C cdvi com 8 cdvigroup com Varistor This device comes with varistor The varistor must be connected on the strike terminal electromagnet operated by the device If this product operates more than strike e
16. o modify its own User code short the blue and the yellow wires Separate the two wires to disable this function 1 Enter the old user code the relay is activated and the green LED lights on 2 Enter the 2 digit sub master code default sub master code A and the red LED lights on to authorize the modification 3 Enter the new user code the green LED lights during 1 second to confirm the new user code The red LED lights off 4 Check the new user code to make sure of the modification SETTING A SUB MASTER CODE The Sub Master code allows the user to change its own code without entering in programming mode For security reasons the code need to be changed periodically This feature makes it easier and faster to change its code 1 Enter the master code twice 12345 default master code the red LED lights on to confirm entry in programming cdvi com 6 cdvigroup com INSTALLATION MANUAL DGA Cast aluminium Digicode Self Contained 2 Press A7 to program a sub master code for the user individual Pin code modification of Group 1 the green LED lights on during 1 second enter the new 2 digit sub master code the green LED lights on during 1 second to confirm programming of the sub master 3 Press A8 to program a sub master code for the user individual Pin code modification of Group 2 the green LED lights on during 1 second enter the new 2 digit sub master code the green LED lights on during 1 seco
17. saisie des termes de modifications des codes utilisateurs la led verte s allume 1 seconde tapez les deux termes de modifications la led verte s allume 1 seconde pour confirmer la programmation 4 Tapez B pour sortir de la programmation la led rouge s teint pour confirmer le retour au mode normal de fonctionnement PROGRAMMATION DU SIGNAL SONORE Le signal sonore est toujours audible en programmation Il en est de m me lors de la commande d ouverture suite la reconnaissance d un code Par d faut lors de la composition du code d ouverture aucun bip touche n est audible Il est possible d autoriser les bips touches en faisant comme suit 1 Tapez 2 fois le code ma tre pour la premi re utilisation le code ma tre usine est 12345 deux bips sont mis pour confirmer l entr e en programmation 2 Tapez AA un bip est mis tapez 0 pour supprimer les bips touches pendant la composition du code d ouverture tapez 1 pour autoriser les bips touches pendant la composition du code d ouverture un bip est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation deux bips sont mis pour confirmer le retour au mode normal de fonctionnement cdvi com cdvigroup com 15 avec lectronique int gr e Noir ALIMENTATION 230 V 12 V 24 V AC 12 V 48 V DC Rouge Rose C1 230 V ALIMENTATION VENTOUSE Verrouillage Marron R1 Orange T
18. sitionnez les 2 chevilles plastiques dans les trous Puis Fixez le fond du DGA sur le support de votre choix l aide des vis cruciformes t tes frais es Passez le c ble lectrique du DGA dans son ouverture et fixez le son support par le haut avec le crochet sup rieur Bloquez le DGA sur son support par l interm diaire de la vis TORX et de son outil sp cifique cl m le coud e Pour finaliser le montage de ce produit placez le cache vis cdvi com cdvigroup com 17 int gr e 18 cdvigroup com INSTALLATION MANUAL DGA Digicode avec lectronique int gr e cdvi com cdvigroup com 19 Reference GO301FRO293V01 Extranet EXE CDVI_ DGA CMYK 5 FR EN 01 Manufacturing Access Control since 1985 CDVI Headquarters Si ge social FRANCE Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX Phone 32 0 5 662 02 50 Fax 32 0 5 662 02 55 CDVI SWITZERLAND Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 87664065 86 0 10 87664165 CDVI IB RICA Phone 34 936 916 551 Fax 34 935 801 278 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 3970 CDVI MAROC Phone 212 0 22 48 09 40 Fax 212 0 22 48 34 69 CDVI SWEDEN Phone 46 0 31 760 19 30 Fax 46
19. uveau 123456 en 6 termes 12345 en 5 termes 1234 en 4 termes CHANGEMENT DU CODE D ENTR E PAR L UTILISATEUR L autorisation de changement de code par l utilisateur est d termin e par la connexion des fils bleu et jaune pas de connexion pour interdire le changement de code Si les fils bleu et jaune sont reli s le changement de code est autoris 1 Composez le code utilis actuellement le relais d ouverture est command la led verte s allume 2 Tapez imm diatement les 2 termes du code de modification A et ou 1 et 3 la premi re utilisation La led rouge s allume pour autoriser le changement 3 Composez le nouveau code d ouverture la led verte s allume 1 seconde confirmant la validation du nouveau code et le retour a un fonctionnement normal la led rouge s teint cdvi com 14 cdvigroup com MANUEL D INSTALLATION DGA Digicode avec lectronique int gr e 4 V rifiez la m morisation du nouveau code en le composant PROGRAMMATION DES TERMES DE MODIFICATIONS 1 Tapez 2 fois le code maitre pour la premi re utilisation le code ma tre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation 2 Tapez A7 pour la saisie des termes de modifications des codes utilisateurs la led verte s allume 1 seconde tapez les deux termes de modifications la led verte s allume 1 seconde pour confirmer la programmation 3 Tapez A8 pour la
20. z 2 fois le code maitre pour la premi re utilisation le code maitre usine est 12345 la led rouge s allume pour confirmer l entr e en programmation 2 Tapez AO pour la temporisation du clavier la led verte s allume 1seconde tapez la dur e de commande en secondes 10 pour 10 secondes 99 pour 99 secondes ou tapez 00 pour obtenir un clairage permanent la led verte s allume 15 pour confirmer la programmation 3 Tapez 1 pour la temporisation du relais 1 la led verte s allume 1seconde tapez la dur e de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes la dur e 00 correspond au fonctionnement bistable du relais 1 la led verte s allume 1s pour confirmer la programmation 4 Tapez A2 pour la temporisation du relais 2 la led verte s allume 1seconde tapez la dur e de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes la dur e 00 correspond au fonctionnement bistable du relais 2 la led verte s allume 1s pour confirmer la programmation 5 Pour sortir de la programmation tapez B la led rouge s teint pour confirmer le retour au mode normal de fonctionnement 4 clignotements la led rouge indique une erreur de saisie REMISE Z RO DU CODE MA TRE En fonctionnement normal reliez les fils blanc et jaune la led verte s allume un bip est mis attendre que la led verte s teigne s parez les fils le code ma tre est de no