Home

TREVINIUM

image

Contents

1. HAYWARD TREVINIUM by Hayward SWIMMING POOL HEAT PUMP UNIT Installation amp Instruction Manual Model HPSSTR 7 ID Intertek 3149010 TREVINIUM Hayward Pool Products Canada Inc T 1 888 238 7665 www haywardpool ca CONTENTS 1 Preface 2 Specifications 2 1 Performance Data of Swimming Pool Heat Pump Unit 2 2 Dimensions for Swimming Pool Heat Pump Unit 3 Installation and Connection 3 1 Installation of System 3 2 Swimming Pool Heat Pumps Location 3 9 How Close to your Pool 3 4 Swimming Pool Heat Pumps Plumbing 3 5 Swimming Pool Heat Pumps Electrical Connection 3 6 Initial Start Up of the Unit 3 7 Water Flow Setting 4 Usage and Operation 4 1 The Functions of the LCD Controller 4 2 Usage of the Controller 4 3 Parameter Table 5 Maintenance and Inspection 5 1 Maintenance 5 2 Trouble Shooting Guide 6 Appendix 6 1 Connection of PCB Illustration 6 2 Wiring Diagram 6 3 Exploded View and Spare Parts List 6 4 Warranty N N CO CONN O O1 O1 5 cO 13 13 14 14 15 17 20 1 PREFACE In order to provide our customers with quality reliability and versatility this product has been made to strict production standards This manual includes all the necessary information about installation debugging discharging and maintenance Please read this manual carefully before you open or maintain the unit The manufacturer of this product will not be held
2. 3 Parameter setting 1 In Cooling mode on the main screen pressing setting value of current parameter 00 2 In Heating mode on the main screen pressing can directly change the setting value of current parameter 01 can directly change the to enter Parameter Interface press EH 3 Single click orl J can select diverse paraments single click the tool button again immediately modify the parameters 00 and 01 parameters can be modified in the boot state Other parameters that non factory commissioning officers can not enter De bug interface with long term key 10s the remote control unit Auto Jump factory debug interface In the interface All parameters can be modified in the boot state After re power Factory debugging interface will not be allowed to re enter To show the set parameter Parameter Setting Button To show parameter No 0 12 please check the system parameter table for the related meanings 10 4 USAGE AND OPERATION 4 Set Clock Single click two numpads of the clock will flicker single click again hours bit starts to flicker this moment pressing P lB can modify the value 5 Timer single click can select timing switch settings If ON and clock s Hours and minutes bit flicker together then continous singly click to enter timer power set Next steps mode is the same as clock set If OFF and cloc Hours and minutes
3. Panneaudefe ade HPXG2008 220020 18 6 ANNEXE 6 3 Vue clat e et liste des pi ces HP70TR NO 12 13 14 15 16 TZ 18 20 9 2 EE E EG 16 Ee EE _ 20 LI 12 R f rence de la pi ce PX95005 310247 PX20000 140151 HPX20000 220169 HPX20000 270004 HPX32009 22015 HPX20000 330134 H H N A HPX2001 3906 N A N A N A HPX95005 310145 HPX2000 3509 HPX2000 3510 PX20000 370003 PX20000 360007 HPX2001 3909 PX20000 360035 N A PX20000 360005 H H H H 13 14 15 Nom de la pi ce Carte de circuits imprim s Interrupteur de d bit 16 LE 29 23 24 25 MET 26 27 N S 28 9 N M 3 32 3 NO 21 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 4 H f rence de la pi ce 2001 3605 2000 3603 2001 1491 2000 3242 Nom de la pi ce HPX20000 110142 H H H 6 ANNEXE 6 4 Garantie GARANTIE LIMIT E DU MANUFACTURIER La garantie Hayward couvre l emplacement d origine la thermo pompe contre tout d faut de pi ces et fabrication pour un 1 an Cette garantie couvre les pi ces et la main d oeuvre pour un 1 an et d bute la date d achat Le compresseur a une garantie de deux 2 ans pi ces seulement et la composante de l changeur en Titanium a une garantie de cina 5 ans La main d oe
4. tel que pr vu respectivement pour chaque mod le voir la plaque signal tique ou le chapitre 2 de mani re obtenir une diff rence de temp rature sur l eau de 2 9 Apr s un fonctionnement durant quelques minutes v rifiez que l air quittant l unit s est refroidi entre 5 et 10 10 L unit tant en service d sactivez la pompe filtrante L unit devrait galement s arr ter automatiquement 11 Faites fonctionner l unit et la pompe de la piscine 24 heures sur 24 jusqu ce que la temp rature de l eau souhait e soit atteinte Quand la temp rature de l eau entrante atteint la valeur d finie l unit s arr te Elle red marre alors automatiquement tant que la pompe de la piscine est en service si la temp rature de la piscine est inf rieure d au moins 2 C la temp rature d finie Contr leur de d bit L unit est dot e d un contr leur de d bit qui active la pompe chaleur lorsque la pompe de filtration de la piscine est en service et la d sactive lorsque la pompe de la filtration est hors service Par manque d eau le code d alarme s affiche sur le r gulateur Voir chapitre 5 2 Temporisation l unit est dot e d un temporisateur r gl sur 3 minutes int gr afin de prot ger les composants du circuit de commande et d liminer toute instabilit en termes de red marrage et toute interf rence au niveau du contacteur Gr ce cette temporisation l unit red marre automatiquement e
5. When the set water inlet temperature is reached the unit shuts off The unit will now automatically restart as long as your pool pump is running when the pool temperature drops more than 2 below set temperature Water Flow Switch the unit is equipped with a flow switch that turns it on when the pool pump is running and shuts it off when the pump shuts off This switch is the same type used in all gas pool heaters and is factory adjusted for normal pool installations If the pool water level is more than a few feet above or below the thermostat knob of the unit your dealer may need to adjust it at initial start up Time Delay the unit is equipped with a 3 minute built in solid state restart delay to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption Even a brief power interruption will activate the 3 minute restart delay and prevent the unit from starting until the 3 minute countdown is completed Power interruptions during the delay period will have no effect on the 3 minute countdown 3 INSTALLATION AND CONNECTION 3 7 Water Flow Setting With the water entry and exit valves being open adjust the by pass valve in order to obtain a difference of 2 C between the inflow and outflow temperature see principle diagram S 3 1 You can verify the switch by seeing the entry exit temperat
6. does not include the repair of damage due to negligence accident freezing or other conditions beyond the normal intended use of the unit This warranty is void if the product is repaired or altered in any way by any persons or agencies other than those authorized by HAY WARD and is in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that apply to this product This warranty applies only within Canada At its option HAY WARD will replace or repair any HAY WARD part that proves defective if such parts are returned to our factory freight collect within the warranty period It is agreed that such replacement or repair is the exclusive remedy available from HAYWARD Unless authorized by HAYWARD and performed by a factory authorized service center HAY WARD is not liable for any labor involved in the removal of defective parts or the installation of replacement parts HAYWARD 1 not liable for damages of any sort whatsoever including incidental and consequential damages Parts returned and services performed under terms of this warranty must be approved by HAY WARD parts returned under terms of this warranty will be repaired or replaced and returned transportation charges prepaid by best and most economical means Hayward Pool Products Canada Inc 2880 Plymouth Drive Oakville ON L6H SR4 Retain this Warranty Certificate in a safe and
7. 13 14 15 16 17 18 19 20 21 22 23 24 25 ADA 26 27 R lt p d 28 9 N 30 40 39 38 31 36 35 34 3 32 Ji HPX95005 310247 21 N N N HPX2001 3909 Terminal Block 3 Connection HPX35012 120001 HPX32010 120003 HPX20000 110142 HPX20000 220068 2 2 2 2 2 2 2 2 A A A A 12 13 14 15 16 17 18 _6 ES ES RES EE 15 EC 17 EE _ 20 2 3 4 5 6 7 8 9 30 31 32 39 34 35 36 37 38 39 40 20 6 APPENDIX 6 4 Warranty HAYWARD HEAT PUMP POOL HEATERS LIMITED WARRANTY The HAY WARD heat pump pool heater is warranted to be free of defects in materials and workmanship for a period of one 1 year for parts and 1 one year for labor Warranty is applicable to the original locaton and owner only and is not transferable The compressor component has a two 2 year limited warranty with parts amp labour warranted the first year and parts only warranted in year two The titanium tube component of the heat exchanger has a five 5 year parts only warranty HAYWARD will not void this warranty due to improper pool chemistry This warranty is valid only if the product is installed according to the HAYWARD specifications This warranty does not include refrigerant or other expendable materials or services such as inspection maintenance or unnecessary service calls due to erroneous operational reports external valve position or electrical service It also
8. responsible if someone is injured or the unit is damaged as a result of improper installation debugging or unnecessary maintenance It is vital that the instructions within this manual are adhered to at all times The unit must be installed by qualified personnel The unit can only be repaired by qualified installer centre personnel or an authorised dealer HVAC Maintenance and operation must be carried out according to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty The Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant This type of pump has the following characteristics 1 Durable The heat exchanger is made of PVC amp titanium the tube can withstand prolonged exposure to corrosives such as chlorine 2 Quiet operation The unit comprises an efficient rotary compressor and a low noise fan motor which guarantees its quiet operation 3 Electronic control board The unit is controlled by a micro controller allowing all operation parameters to be set Operation status can be displayed on the control panel 2 SPECIFICATIONS 2 1 Performance Data of Swimming Pool Heat Pump Unit REFRIGERANT R410A Unt Model HP55TR HP7OTR BTU h 55 000 70 000 Compressor Quantity J 101001 Compressors Rotar
9. bit flicker together then continous to singly click enter timer power set 6 KEYLOCK along press on for Seconds on the main screen the keyboard can be locked displaying an icon lt T di Mia Disolav Conversion Press and lt at the same time for 5 seconds to choose Celsius degree or Fahrenheit degree display 11 4 USAGE AND OPERATION 4 3 Parameter Table ror Settling moe Rer Settingthesting mode ENE 1 Ky w or s meme Tantei 12 5 1 Maintenance 5 MAINTENANCE AND INSPECTION Check the water supply device and the release often You should avoid the condition of no water or air entering into the system as this will influence the unit s performance and reliability You should clear the pool spa filter regularly to avoid damage to the unit as a result of a clogged filter The area around the unit should be dry clean and well ventilated Clean the side heating exchanger regularly to maintain good heat exchange and conserve energy The operation pressure of the refrigerant system should only be serviced by a certified technician Check the power supply and cable connection often Should the unit begin to operate abnormally switch it off and contact your qualified technician Discharge all water in the water pump and water system so that freezing of the water inlet the pump or water system does not occur You should discharge the water at the bot
10. c bles Si l unit commence connaitre des dysfonctionnements d sactivez la et contactez votre technicien qualifi Videz toute l eau de la pompe eau et du syst me d alimentation en eau de telle sorte que l eau entrant dans la pompe ou dans le syst me d alimentation en eau ne puisse pas se congeler Vous devez vacuer l eau pr sente au fond de la pompe eau si l unit n est pas utilis e sur une dur e prolong e Veuillez v rifier minutieusement l unit et remplir compl tement le syst me d eau avant de l utiliser pour la premi re fois apr s une inutilisation sur une longue dur e L installation doit tre r alis e en conformit avec le Code national de l lectricit et uniquement par le personnel autoris 5 2 Guide de d pannage Contr leur Dysfonctionnement Solution D faut sonde entr e d eau P01 Le captour esi ouvert ou pr sente V rifiez ou remplacez le capteur un court circuit D faut sonde sortie d eau PO2 Le cap ea presente V rifiez ou remplacez le capteur un court circuit D faut sonde de d givrage P05 ee an B auvent oU presenta V rifiez ou remplacez le capteur un court circuit D faut sonde temp rature 04 Le capteur est ouvert ou pr sente V rifiez ou remplacez le capteur ext rieure un court circuit D bit d eau en volume insuffisant diff rence de pression d eau trop faible trop lev e Antigel en mode refroidissement E07 Quantit d eau sortante trop faible V rnez gen
11. ch ma de cablage 7 CC G ib 1112 9 9 Vers Vers pompe alimentation eau lectrique 208 230V 60Hz AT Temp rature ambiante CT Temp rature d vaporation S 9 gt OQ O Compresseur amp 6522 ZI ST Z1 EEV Elecronic expand vavle FM Moteur du ventilateur FS Interrupteur d bit HP Pressostat haute pression IT Temp rature entr e d eau KM1 Contacteur du compresseur LP Protection basse pression OT Temp rature sortie d eau SUT Temp rature d aspiration TC Transformateur 4V Vanne 4 voies HP OTR 16 6 ANNEXE 6 3 Vue clat e HP55TR N AO 7 M e A l nu M CN Dr 1 Cad LE 9 x Ju pli v ur 1 17 10 17 6 ANNEXE 6 3 Liste des pi ces HP55TR SN R f rence de la pi ce Nom de la pi ce No de pi ce _ 567 202 Eveporaleur HPXGA0T 202 2 2000022018 Plastique de protection du ventlateur HPX20000 220188 s 20000 330124 Moteurdeventlateur HPX20000 830124 3500270 Venlaeuraxd HPX8500 2701 2004 1497 Vanne avais HPX2004 1437 20000 0041 Compresseur HPX20000 110047 320083 120008 Echangeur de chaleur en Thane HPXG2008 120008 32008 220020
12. convenient location for your records Hayward Pool Products Canada Inc T 1 888 238 7665 www haywardpool ca HAYWARD HAYWARD TREVINIUM par Hayward THERMOPOMPE POUR PISCINE Manuel d instructions et d installation Modele HP55TR 7 ID Intertek 3149010 TREVINIUM Hayward Pool Products Canada Inc T 1 888 238 7665 www haywardpool ca SOMMAIRE 1 Pr face 2 Caract ristiques techniques 2 1 Donn es techniques de la pompe chaleur 2 2 Dimensions 3 Installation et raccordement 3 1 Illustration de linstallation 3 2 Thermopompe 3 3 A quelle distance de la piscine l installer 3 4 Installation des conduites 3 5 Raccordement lectrique 3 6 Premier d marrage 3 R glage du debit d eau 4 Utilsation et fonctionnement 4 1 Fonctions du contr leur LCD 4 2 Utilisation du contr leur 4 3 Table de parametres 5 Entretien et inspection 5 1 Entretien 5 2 Guide de d pannage 6 Annexe 6 1 Sch ma de raccordement du PCB 6 2 Sch ma de c blage 6 3 Vue clat e et liste des pi ces 6 4 Garantie N N CO CONN O O1 O1 gt cO 13 13 14 14 15 17 20 1 PREFACE Pour que vos clients puissent b n ficier de qualit fiabilit et flexibilit ce produit a t concu pour satisfaire strictement aux normes de fabrication Le pr sent manuel inclut toutes les informations n cessaires concernant l installation l limination des dys
13. e circuit against voltage surges refer to the nameplate for the voltage 3 Always shut down the main Power supply before opening the electrical control box 3 6 Initial Start Up Start up Procedure After installation is completed you should follow these steps 1 Switch on the filtering pump verify flow to and from the pool 2 Check that all the water valves are open and that the water flows into the unit before switching on heating or cooling 3 Ensure that the unit is connected correctly to the main Power supply refer to the wiring diagram or chapter 6 4 Rotate the fan by hand to ensure that it turns freely and that the turbine is properly tightened with the motor shaft 5 Check that the condensate drainage hose is properly attached and free of blockages 6 Switch on the power supply to the unit then press the On Off key on the wire controller 7 Ensure that no ALARM code is displayed when the unit is ON see Trouble shooting guide 8 Set the water flow using the by pass valve see chapter 3 1 as described for each different model see the control panel or chapter 2 to obtain a 2 C difference in water temperature 9 After running a few minutes make sure the air leaving the unit is cooler between 5 10 10 With the unit operating turn the filter pump off The unit should also turn off automatically 11 Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is reached
14. emperature 3 INSTALLATION AND CONNECTION 3 4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing except bypass please set the flow rate according to the nameplate The water pressure drop is less than 1 5psi 10KPa at maximum flow rate Since there are no residual heat or flame temperatures the unit does not need copper heat sink piping PVC pipes can be run straight into the unit Location connect the unit in the pool pump discharge return line downstream of all filter and pool pumps and upstream of any chlorinators ozonators or chemical pumps You will need to use 11 2 male PVC adapter to connect to heat pump Consider adding a quick coupler fitting at the unit inlet and outlet to allow easy draining of the unit for winterizing and to provide easier access should servicing be required Condensation since the heat pump cools the air down about 4 5 C water may condense on the fins of the horseshoe shaped evaporator If the relative humidity is From pump Z 2 SN W i V 7 5 4 COUPLER RECOMMENDED f NN A a es I NW 7 Horizontal view very high this could be as much as several litres an hour The water will run down the fins into the basepan and drain out through the barbed plastic condensation drain fitted on the side of the basepan This fitting is designed t
15. ent Accessoires d installation L usine ne fournit que l unit de thermopompe les autres accessoires repr sent s sur l illustration sont des pi ces d tach es n cessaires pour le syst me d alimentation en eau ils sont fournis par l utilisateur ou l installateur Attention Suivre attentivement les tapes suivant lors de la mise en marche initiale Ouvrir toute la vanne et remplir avec de l eau Assurez vous que la pompe et les boyaux sont plein d eau Fermer la vanne et d marrer la thermopompe ATTENTION Il est peut tre n cessaire que les boyaux doivent tres plus haut que la piscine L installation doit tre effectu e conform ment aux exigences de NEC et CEC par le personnel autoris seulement 3 INSTALLATION ET RACCORDEMENT 3 2 Thermopompe L unit remplit correctement ses fonctions tout emplacement externe condition que les trois facteurs suivants soient pr sents 1 Air neuf 2 Electricit 3 Tuyauterie destin e au filtre de la piscine L unit peut tre install e quasiment tout endroit l ext rieur En ce qui concerne les piscines int rieures veuillez contacter le fournisseur Contrairement un chauffe eau gaz elle ne pose pas de probl me d appels d air ou de veilleuses dans les zones vent es NE PLACEZ pas l unit au sein d une zone ferm e ayant un volume d air restreint l air refoul par les unit s sera recycl NE PLACEZ pas l unit aupr s d arbu
16. et ex cut par un centre de service autoris par le manufacturier HAYWARD n est pas responsable des dommages de quelques sortes incluant les accidents ou les dommages indirects HAYWARD doit approuver le retour des pi ces et les r parations seront ex cut es dans les termes de cette garantie Toutes les pi ces retourn es avant le terme de la garantie seront r par es frais de port pay s dans les meilleurs d lais et aux co ts les plus conomiques Hayward Pool Products Canada Inc T 1 888 238 7665 www haywardpool ca HAYWARD
17. fonctionnements le destockage et l entretien Veuillez lire attentivement ce manuel avant d ouvrir l unit ou de r aliser des op rations d entretien sur celle ci Le fabricant de ce produit ne sera en aucun cas tenu responsable en cas de blessure d un utilisateur ou d un endommagement de l unit suite d ventuelles erreurs lors de l installation de l limination des dysfonctionnements ou d un entretien inutile I est primordial de suivre tout moment les instructions sp cifi es dans ce manuel L unit doit tre install e par un personnel qualifi Les r parations peuvent seulement tre effectu es par le personnel qualifi du centre d installation ou un distributeur agr L entretien et les diff rentes op rations doivent tre r alis s la fr quence et aux moments recommand s tel que sp cifi dans le pr sent manuel e N utilisez que des pi ces d tach es originales normalis es Toute recommandation non annule la garantie L unit de thermopompe r chauffe l eau de la piscine et maintient une temp rature constante Ce type de pompe pr sente les caract ristiques suivantes 1 Durabilit L changeur thermique est r alis en PVC amp titane le tube est en mesure de r sister une exposition prolong e aux agents corrosifs tels que le chlore 2 Faible niveau sonore L unit comprend un compresseur rotatif efficace et un moteur de ventilateur bruit r du
18. hange the sensor Check or change the sensor Check or change the sensor Check the water flow volume or system obstruction Check the water flow volume or outlet water temp sensor and the gas system pressure to judge whether the gas loop is blocked or the freon is suitable _ Check through the low pressure switch and the gas system pressure to judge whether there is leaking or the freon is not enough Check the water flowvolume water pump and flowswitch is failure ornot Check the water flow rate or water system is jammed or not Check the wire connection 13 6 APPENDIX 6 1 Connection of PCB Illustration 14 symbol OUT Compressor of system 220 230VAC OUI OUT3 Water pump 220 230VAC 4way valve 220 230VAC High speed offan motor 220 230VAC Low speedof fan motor 220 230VAC NET GND 12V KYIN On Off Switch input no use HIP GND Flow switch input normal close LP GND GND AC N Neutral wire Low pressure protect High pressure protect 12 GND GND 14 GND 15 GND No Es 5 LE Lia Era 16 6 APPENDIX 6 2 Wiring Diagram HP55TR SUPPLY TOPUMP 208 230V 60Hz AT Ambient temperature Compressor T2 5K CT Coil temperature 9 22 EEV Electronic expand valve e o r 3 E r1 BUT B 3 al a LL T FM Fan motor FS Flow switch HP Highpressure protection IT Inlet wa
19. i le syst me d alimentation en eau est bloqu V rifier la connexion des c bles 13 6 ANNEXE 6 1 Sch matique de raccordement du PCB Compresseur du syst me 1 220 230VAC 2 Pompe de filtration 220 230VAC Moteur de ventilateur grande vitesse de 220 230 volts c a ours Moteur de ventilateur faible vitesse de 220 230 volts c a NET GND 12V Alimentation du controleur externe Entr e de l interrupteur marche arret Entr e du d tecteur de d bit NC Sonde de protection basse pression Temp l aspiration entr e Temp rature de l eau l entr e 136No Temp rature de l eau la sortie Temp du serpentin entr e dd Sonde de protection haute pression n Temp rature ambiante entr e 14 6 ANNEXE 6 2 Sc ma de cablage HP55TR Vers Vers pompe alimentation eau lectrique 208 230V 60Hz AT Temp rature ambiante CT Temp rature d vaporation t T2 COMP Compresseur zizlau zielzieiziaziezixz EEV Elecronic expand vavle O FM Moteur du ventilateur Tu o nl al FS Interrupteur d bit S E Ex HP Pressostat haute pression M Temp rature entr e d eau KM1 Contacteur du compresseur LP Protection basse pression OT Temp rature sortie d eau SUT Temp rature d aspiration TC Transformateur 4V Vanne 4 voies HP55TR 15 6 ANNEXE 6 2 S
20. i oau de temp rature d eau sortante Protection antigel de premi re E19 Temp rature ambiante ou de l eau classe en hiver entrante trop faible Protection antigel de seconde E29 Temp rature ambiante ou de l eau classe en hiver entrante encore plus faible Pression du syst me de gaz trop lev e ou d bit d eau trop faible V rifiez le d bit d eau ou l obstruction du syst me Diff rence de temp rature entre l eau en sortie et l eau en entr e V rifiez le pressostat haute pression Protection haute pression et la pression du syst me de gaz pour ou vaporateur obstru ou d bit d air trop faible Pression du syst me de gaz trop faible ou d bit d air trop faible ou vaporateur obstru Protection basse pression Eau absente peu d eau dans le syst me d alimentation en eau Temp l entr e et la sortie de l eau LER Affichage du Cycle de d givrage code de d givrage 2 Dysfonctionnement du contr leur Probl me de communication E08 LED od de la connexion PCD Flux par d faut valuer si la boucle de gaz est bloqu e ou le fr on n est pas suffisant V rifiez le pressostat basse pression et la pression du syst me de gaz pour valuer s il existe une fuite ou le fr on n est pas suffisant V rifiez le d bit d eau v rifiez la pompe eau et le r gulateur de d bit pour voir s ils pr sentent d ventuels dysfonctionnements V rifiez le d bit d eau ou s
21. it qui garantit un faible niveau sonore en service 3 Tableau de commande lectronique L unit est command e par micro contr leur qui permet de d finir tous les param tres de fonctionnement L tat de fonctionnement peut tre affich sur le panneau de commande 2 CARACTERISTIQUES TECHNIQUES 2 1 Donn es techniques de la thermopompe REFRIGERANT R410A Nombre de compresseurs 4100 100 Type de compresseur Nombre de ventiateurs 1 d Direction du ventilateur Horizontale Horizontale D bit d eau oo omh 45 6 Chauffage Temp rature Ambiante BS BM 24 C 19 C Tem rature de l eau entrer sortie 26 C 28 C 2 CARACTERISTIQUES TECHNIQUES 2 2 Dimensions Modele HP55TR HP70TR 2 E ND m ie S ZR NW III III NN ANN WW NS 22 MW SS 4 lt 7 L SS 22 x 6 Z 2 Entr e d eau 1 5 Sortie d eau 1 5 Drainage 3 4 0000000000 LULU Unit mm po par HP55TR HP7OTR B 455 79 470 85 _ D 630 248 740292 270 10 6 400 15 8 82 3 3 82 3 3 3 INSTALLATION ET RACCORDEMENT 3 1 Illustration de l installation Filtre sable ou autre type de filtre Pompe de filtration Soupape 4 I Vanne d entr d eau i gt lt Vanne sortie Cellule Retour d eau d eau lectrolyseur ou autre traitem
22. ncore changement des param tres 00 et 01 peuvent tres modifi s dans cette tat de d marrage D autres param tres ne peuvent tres modifi s par vous m me En appuyant longuement sur L interface De Bug jusqu a 10 secondes Le panneau de contr le va automatiquement tre en mode de d bogage Dans ce menu tous les param tres peuvent tres modifi s dans cet tat de d marrage Apr s une remise en alimentation le menu de d bogage n autorise plus r entrer Affichage des param tres Bouton de selection param tres Pour afficher les param tres No 0 12 s il vous plait consulter le tableau des param tres du syst me pour les significations 4 UTILISATION ET FONCTIONNEMENT 4 R glage de l heure Appuyer sur deux chiffres de l horloge se met clignoter appuyer de nouveau sur le bouton les heures commence clignoter ce moment en appuyant FE modifier les heures seulement Appuyer sur une fois de plus les minutes se met clignoter ce moment en appuyant T F1 modifier les minutes 8 kg 5 Minuterie Appuyer sur deux chiffres de l horloge se met clignoter appuyer sur le bouton s lectionner les param tres de la minuterie Si ON les heures et les minutes commence cli gnoter ensemble continuer en appuyant sur afin d entrer dans le r glage de la minuterie Suivre le de nouveau tapes du r glage de l heures Si OFF les heures et les minutes commence clign
23. nviron 3 minutes apr s toute coupure du circuit de commande M me une coupure de courant de courte dur e active le temporisateur r gl sur 3 minutes et emp che tout d marrage de l unit jusqu ce que la dur e limite de 3 minutes se soit coul e Des coupures de courant pendant la p riode de temporisation n ont aucun effet sur la dur e limite de 3 minutes 3 INSTALLATION ET RACCORDEMENT 3 7 R glage du d bit d eau Les vannes d entr e et de sortie d eau tant ouvertes ajuster la vanne dite by pass de facon obtenir une diff rence de 2 C entre la temp rature d entr e et de sortie d eau voir sch ma de principe S 3 1 Vous pouvez v rifier le r glage en visualisant les temp ratures entr e sortie directement sur le panneau de commande Temp rature d entr e eau Temp rature de sortie eau Note L ouverture de la vanne dite by pass engendre un d bit moins important d ou une augmentation du AT La fermeture de la vanne dite by pass engendre un d bit plus important d ou une diminution du AT 4 UTILISATION ET FONCTIONNEMENT 4 1 Fonction du contr leur LCD L interface utilisateur et l utilisation comme suit s 3 03 2 97888 Directions Symbole r frig rant allum lors de la r frig ration ON OFF No LIMIT Symbole du chauffage allum lors du P WE w chauffage ON OFF LIMIT LILI TEMP C VOL Symbole du mode Automati
24. o accept 3 4 clear vinyl tubing which can be pushed on by hand and run to a suitable drain It is easy to mistake the condensation for a water leak inside the unit NB a quick way to verify that the water is condensation is to shut off the unit and keep the pool pump running If the water stops running out of the basepan it is condensation AN EVEN QUICKER WAY IS TO TEST THE DRAIN WATER FOR CHLORINE if there is no chlorine present then it S condensation 3 INSTALLATION AND CONNECTION 3 5 Swimming Pool Heat Pumps Electrical Connection NOTE although the unit heat exchanger is electrically insulated from the rest of the unit this simply prevents the flow of electricity to or from the pool water Grounding the unit is still required to protect you against short circuits inside the unit NOTE ensure that the available electrical Power supply and the network frequency are matched to the required operating current taking account of the appliance s specific location and the current required to supply any other appliances connected to the same circuit 1 See the wiring diagram chapter 6 3 2 Ensure that the unit is supplied with the specified voltage The terminal block is located on the right side of the unit There are three connections for the Power supply and two connections for the filtering pump control Enslavement The Power supply line must be properly matched with a motor supply type fuse or a main circuit breaker to protect th
25. on de la pression de l eau est inf rieure 10 kPa 1 5 psi Du fait qu il n existe pas de chaleur r siduelle ou temp rature de flamme l unit ne requiert pas de tuyauterie en cuivre destin e la dissipation thermique Les tuyaux en PVC peuvent s tendre directement jusqu l unit Emplacement raccordez l unit la conduite de refoulement retour de la pompe pour piscine en aval de l ensemble des pompes filtrantes et pour piscine et en amont de tous les chlorateurs ozonateurs ou pompes chimiques Vous devez utilizer des raccords en pvc male viss 172 pour vous adapter sur la thermopompe Veillez ajouter un raccord rapide au niveau de l entr e et de la sortie de l unit afin de simplifier la purge durant la p riode hivernale et de faciliter l acc s si un entretien s av re n cessaire Condensation la thermopompe refroidissant l air d environ 4 5 degr s l eau peut se condenser sur les ailettes de l vaporateur en forme de fer cheval Si l humidit A partir de la pompe RACCORD PVC RECCOMMANDE relative est tr s lev e la quantit d eau condens e peut s lever plusieurs litres par heure L eau descend le long des ailettes pour parvenir dans bac collecteur et est vacu e gr ce au dispositif de purge destin la condensation en mati re plastique et cannel situ sur le c t du bac collecteur Ce dispositif a t concu pour recevoir un tubage de d versement en vinyle de 3 4
26. oter ensemble continue en appuyant sur afin d entrer dans le r glage de la minuterie 6 V rrouillage des touches Appuyer longuement sur pendant 5 secondes sur le menu d faut le clavier peut tre verrouill affichant une ic ne 7 Affichage ge la conversion de la temp rature Appuyez sur et a en m me temps pendant 5 secondes pour choisir l affichage en Celsius ou en Fahrenheit 11 4 UTILSATION ET FONCTIONNEMENT 4 3 Tableau des parametres Temp de l eau de retour Reglage uius l eau de C de l eau de R glage mode automatique R glable Oe a fs 12 5 ENTRETIEN ET INSPECTION 5 1 Entretien V rifiez souvent le dispositif d alimentation en eau et le d verrouillage Vous devez viter l tat o ni de l eau ni de l air ne p n tre dans le syst me tant donn que cela influence les performances et la fiabilit de l unit Veuillez nettoyer r guli rement le filtre de la piscine spa afin d viter tout endommagement de l unit li l obstruction du filtre La zone entourant l unit doit tre s che propre et bien ventil e Nettoyez r guli rement l changeur thermique afin de pr server un bon change thermique et donc d conomiser l nergie La pression de fonctionnement du syst me refroidisseur doit uniquement tre trait e par un technicien sp cialis V rifiez souvent l alimentation lectrique et le raccordement des
27. que Temporairement T LI MODE 9 Horloge bouton de minuterie MODE Bouton d outil SET ON OFF bouton bouton annulations y annule l op ration courante revenir la op ration pr c dente 4 Vers le bas 4 2 Utilisation du contr leur 4 Fermeture dans deux minutes si aucune pression 1 lectrification Apr s avoir v rifi que tout fonctionne faire passer le courant et mettre en veille avec l cran qui affiche ce qui suit xha s 23 4 97 88 88 H d D Affichage d heure 24 heures O spon c a d l cran montre 21 00 PM r 3 Appuyer sur y pour 2 secondes jusqu au message suivant sur l cran 63228888 Bouton changement F min C VOL Pavillon d aspiration de la temp rature du r servoir Sortie de la temp rature du r servoir 4 UTILISATION ET FONCTIONNEMENT 10 2 Sur le menu d faut appuyer sur pendant 2 secondes et l unit va changer entre le mode chauffage ou le mode re SET froidissement de l eau 3 Choix des param tres 1 En mode refroidissement dans le menu d faut appuyer sur E t afin de changer la valeur du param tre 00 2 En mode chauffage dans le menu d faut appuyer sur DA afin de changer la valeur du param tre 01 it 3 Appuyer une fois sur afin d tre dans le menu Param tre appuyer afin de s lectionner divers param tres Appuyer sur le bouton Outil e
28. qui peut tre pos la main et s adapter sur une purge appropri e On peut facilement confondre la condensation et une fuite d eau au sein de l unit NB pour v rifier rapidement que cette eau provient de la condensation arr tez l unit et maintenez la pompe de la piscine en service Si l eau ne s coule plus du bac collecteur il s agit de condensation UN TEST ENCORE PLUS RAPIDE consiste TESTER LA PRESENCE DE CHLORE DANS L EAU DE PURGE Si elle ne contient pas de chlore il s agit de condensation 3 INSTALLATION ET RACCORDEMENT 3 5 Raccordement lectrique REMARQUE bien que l changeur thermique de l unit soit isol lectriquement du reste de l unit il emp che tout simplement l lectricit de circuler vers et en provenance de l eau de la piscine est tout de m me n cessaire de mettre l unit la masse pour vous prot ger des courts circuits au sein de l unit REMARQUE v rifiez que l alimentation lectrique disponible et la fr quence du r seau correspondent au courant de fonctionnement requis en prenant en consid ration l emplacement sp cifique de l appareil et le courant n cessaire pour alimenter tout autre appareil connect au m me circuit 1 Observez le sch ma de c blage chapitre 6 3 2 V rifiez que l unit est aliment e avec la tension sp cifi e Le bloc de jonction se trouve du c t droit de l unit Trois connexions sont destin es l alimentation lectrique et de
29. rements of NEC and CEC by authorized personnel only 3 INSTALLATION AND CONNECTION 3 2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are present 1 Fresh Air 2 Electricity 3 Pool filter piping The unit may be installed virtually anywhere outdoors For indoor pools consult the supplier Unlike a gas heater it has no draft or pilot light problem in a windy area DO NOT place the unit in an enclosed area with a limited air volume where the units discharge air will be re circulated DO NOT place the unit next to shrubs which can block the air inlet These locations deny the unit a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery Air inlet 52 3 3 How Close To Your Pool Normally the pool heat pump is installed within 7 5 metres of the pool The longer the distance from the pool the greater the heat loss from the piping For the most part the piping is buried Therefore the heat loss is minimal for runs of up to15 metres 15 metres to and from the pump 30 metres total unless the ground is wet or the water table is high A very rough estimate of heat loss per 30 metres is 0 6 Kw hour 2000BTU for every 5 difference in temperature between the pool water and the ground surrounding the pipe which translates to 396 to 5 increase in operating time for the water to reach the desired t
30. stes qui peuvent bloquer l entr e d air A ces emplacements l unit ne peut plus b n ficier d une source continue d air neuf ce qui r duit son efficacit et peut emp cher une puissance calorifique ad quate Evacuatten d air 3 3 A quelle distance de la piscine l installer En temps normal la thermopompe est install e moins de 25 pieds de la piscine Plus la pompe est loign e de la piscine plus la d perdition thermique partir de la tuyauterie est lev e La majeure partie de la tuyauterie est enterr e De fait la d perdition thermique est minimale pour des distances allant jusqu 50 pieds 50 pieds jusque et partir de la pompe savoir 100 pieds au total hormis si le sol est humide ou que le niveau hydrostatique est lev Selon une estimation tr s approximative la d perdition thermique s l verait 0 6 Kw heure pour 100 pieds 2000BTU pour toute diff rence de temp rature gale 5 degr s entre l eau de la piscine et le sol entourant la tuyauterie ce qui rallonge de 5 la dur e de service pour que l eau atteigne la temp rature souhait e 3 INSTALLATION ET RACCORDEMENT 3 4 Installation des conduites L changeur thermique au titane d bit nominal exclusif des thermopompes pour piscine ne requiert pas d installation de conduites sp cifiques hormis la d rivation le d bit est d fini conform ment la plaque signal tique Pour un d bit maximal la diminuti
31. ter temperature KM1 Contactor of compressor FS LP IHE LP Low pressure protection Controlle OT Outet water temperature SUT Suction temperature TC Transformer 4V 4 way valve HP55TR 15 6 APPENDIX 6 2 Wiring Diagram HP70TR TO POWER SUPPLY 208 230V 60Hz TO PUMP AR e al temperature Compressor CH Compressor heater gt 2 E 9 S oj gt CT Coil temperature a EEV Electronic expand valve FM Fan motor FS Flow switch HP11 High pressure protection 4 HP12 High pressure protection IT Inlet water temperature M1 Contactor of compressor KS Relay coil of compressor start LP Low pressure protection OT Outlet water temperature SUT Suction temperature TC Transformer HP OTR 16 6 APPENDIX 6 3 Exploded View HP5STR 1 17 10 CN 18 17 6 APPENDIX 6 3 Spare Parts List HP55TR SN PartCode PartName _ Part Number 1 3407 1202 Evaporator 7 HPX8407 1200 2 200002200188 FanNe HPX20000 220188 3 20000330124 FanMotr HPX20000 330124 4 3500 2701 AxsBlowerFan HPX850027001 5 2004 1487 4Wayvave HPX2004 1487 __ 6 20000110041 Comprsso 7 HPX20000 110041 8 32008 120008 Titanium Tube Heat Exchanger HPX32008 120008 9 32008220020 FroPanl HPX32008 220020 18 6 APPENDIX 6 3 Exploded View and Spare Parts List HP7OTR 11 12
32. tom of the water pump if the unit will not be used for an extended period of time You should check the unit thoroughly and fill the system with water fully before using it for the first time after a prolonged period of no usage Installation must be performed in accordance with the NEC CEC by authorized person only 5 2 Troubleshooting Guide LCD Controller Water inlet temp Sensor failure Water outlet temp Sensor failure Coil sensor failure Ambient sensor failure Temp differential between wnter in and water out is too large 2 __ nti freezing under cooling mode The first class freezing protection in winter The second class freezing protection in winter High pressure protect Low pressure protect Flow switch failure 3times water in and water out temp differece protectionin 30 minutes Defrosting Communication failure Reason The sensor is open or short drcuit The sensor is open or short circuit The sensor is open or short drcuit The sensoris open or short circuit Water flow volume not enough water pressure difference is too low Outlet water is too low Ambient or inlat water temp is too low Ambient or inlet water temp is too lower Gas System pressure is too high Gas System pressure is too low No water little water in water system Water flow rate not enough LED controller and The PCB connection failure Resolution Check or change the sensor Creck or c
33. ures directly on the control panel Water inlet temperature Water outlet temperature Note Opening the by pass valve creates a weaker flow which leads to an increase in AT Closing the by pass valve creates a stronger flow which leads to a decrease in AT 4 USAGE AND OPERATION 4 1 Function of the LCD Controller User Interface and Usage as the following Directions Refrigeration symbols Displayed when refrigeration 3 OFF HH HI Hi ON OFF No LIMIT AN E Heating Symbols Displayed when heating Hr F min ON OFF NOLIMIT un e C VOL Automatic mode symbol Temporarily useless IN Clock timer function button Tool butlon E H ONIOFF cancel key cancel the current operation Back tothe previous step ofthe operation 4 2 Usage of the Controller Closing screen if noaclion in two minutes 1 Electrify After checking everything is okay electrify and enter into standby state with the screen showing as the following F min x C VOL Time dispaly 24 hours e g the screen shows 21 00 PM a menon Press for 2 seconds to start unit the screen showing as the following eC C3 918808 F min HBH Inlet of the tank temperature Switch Key SET E IN NT Outlet of the tank temperature 4 USAGE AND OPERATION 2 Switch mode on the main screen along press ser for 25 the unit switches between cooling or heating mode
34. uvre n est couverte que pour une p riode de un 1 an Hayward n annulera pas cette garantie cause d une chimie de l eau inad quate Cette garantie est valide si l appareil a t install selon les caract ristiques tablies dans ce manuel Cette garantie n inclut pas le service tels l inspection l entretien ou les appels de service cause de rapports d op rations erron s de la mauvaise position d un robinet ext rieur ou de la n cessit du soutien technique Elle exclut galement le r frig rant la r paration ou les dommages caus s par la n gligence les accidents ou autres conditions supposant l utilisation non appropri e de l appareil Cette garantie sera rendue nulle si le produit est r par ou alt r d une quelconque facon par une personne ou une entreprise autre que celles autoris es par HAYWARD Cette Garantie a pr s ance sur toutes les autres garanties expresses ou tacites crites ou orales l n existe pas de garantie tacite de qualit marchande ou de bon fonctionnement couvrant cet appareil Cette garantie s applique seulement au Canada HAYWARD d cidera s il remplace ou r pare toutes pi ces de HAYWARD qui est d fectueuse et si une des pi ces est retourn e notre manufacture les frais transport seront couverts dans la p riode de garantie 1 est entendu que ce genre de remplacement ou de r paration soit la seule solution disponible de HAYWARD moins que le service ne soit autoris par HAYWARD
35. ux la commande de la pompe filtrante subordination La ligne d alimentation lectrique doit tre dot e de mani re appropri e d un fusible de type alimentation moteur ou d un disjoncteur afin d viter des surtensions sur le circuit voir la plaque signal tique pour conna tre la tension concern e 3 Prenez toujours garde d arr ter l alimentation principale avant d ouvrir la boite de commande lectrique 3 6 Premier d marrage Proc dure de d marrage une fois l installation termin e suivez les tapes suivantes 1 Mettre en marche la pompe et v rifier l arriv et la sortie d eau de la piscine 2 V rifiez que tous les robinets d eau sont ouverts et que l eau s coule vers l unit avant de passer au chauffage ou refroidissement 3 Assurez vous que l unit est connect e correctement l alimentation principale voir le sch ma de c blage ou chapitre 6 4 Faites pivoter le ventilateur la main afin de v rifier qu il peut tourner librement et que la turbine est fix e correctement sur l arbre du moteur 5 V rifiez que le tuyau de purge du condensat est fix correctement et ne pr sente aucune obstruction 6 Activez l alimentation lectrique destin e l unit puis appuyez sur le bouton On Off sur le panneau de commande 7 Assurez vous qu aucun code d ALARME ne s affiche lorsque l unit est sur ON voir guide de d pannage 8 Fixez le d bit d eau l aide de la vanne by pass voir chapitre 3 1
36. y Fan Quantity 1 e 1 Fan Direction Horizontal Horizontal Water Flow Volume Impera US mih 45 6 Heatino Ambient temp DB WB 24 C 19 C Water temp in out 26 28 2 SPECIFICATIONS 2 2 Dimensions for the Swimming Pool Heat Pump Unit Model HP55TR HP70TR 7 2 NN if If s NY Ww DH Z 7 SS 22 x 6 Z L L L L L L L L LA T Unit mm inch A 430 17 0 430 17 0 120 4 8 120 4 8 270 10 6 400 15 8 8213 3 82 3 3 3 INSTALLATION AND CONNECTION 3 1 Installation Illustration r UU Sand filter or other type filter Water inlet Water pump SS SN S NN AU gos NY UW W AWS Water supply 7 Min E li ut SSS SN S Water outlet Chlorinator cell Installation items The factory only provides the heat pump unit the other items in the illustration are necessary spare parts for the water system provided by users or the installer Attention Please follow these steps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe inlet be higher than the pool surface Installation must be performed in accordance with the requi