1. Manual 0 2953 IHERMAL DYNAMICS A THERMADYNE Company 1Torch Adapter Kit 82 Benning Street West Lebanon NH 03784 USA Catalog 7 3478 603 298 5711 www thermal dynamics com Installation Instructions General Information These instructions cover Thermal Dynamics Adapter Kit No 7 3478 The kit connects 1Torch SL60 or SL100 Torches equipped with O2B connectors or the ATC Adapter Kit to the following equipment e Miller Spectrum 625 Power Supply Do not use this kit on any other equipment Supplied Parts The kit includes e Adapter Assembly including Wire Harnesses with Connectors e Strain Relief e Tie Wraps use as needed e Instructions A WARNINGS Disconnect primary input power to the system before starting the installation Shut off the gas supply and bleed down the system Only a qualified technician should perform this procedure Procedure 1 Remove the Power Supply Cover per manufacturer s instructions 2 Disconnect the original torch per manufacturer s instructions 3 Slide back the insulation sleeve covering the pilot lead with ring tongue terminal on the Torch Leads or ATC Adapter Kit Cut the ring terminal off the pilot lead Strip back the insulation approximately 1 4 6 mm from the end of the wire 4 Remove the tie wrap and the insulator from two wires connected together on the Torch Leads or ATC Adapter Kit Disconnect the two joined wires 5 Remove the securing nut from the
2. Strain Relief provided in this kit 6 Slide the Strain Relief onto the Torch Leads or ATC Adapter Kit leads 7 Pass the ends of the Torch Leads or ATC Adapter Kit leads through the access opening in the power supply Pass the strain relief securing nut over the Torch Leads or ATC Adapter Kit leads Use the strain relief nut to secure the strain relief to the power supply Do not tighten the strain relief onto the leads 8 Thread the Torch Adapter securely onto the Torch Leads or Adapter Kit Leads Negative Plasma O2B fitting Do not use sealant Use a wrench to hold the Adapter Kit brass fitting stationary while using another wrench to turn the Torch Leads or ATC Adapter Kit O2B fitting Do not overtighten 2003 Thermal Dynamics Corp Printed in USA MILLER and Spectrum are registered trademarks of Miller Electric Mfg Co July 7 2003 7 Juilliet 2003 1 Manual Manuel 0 2953 9 Use the mating wire connectors to connect the Adapter Kit wire harness to the Torch Leads or Adapter Kit Leads Check for secure connections 10 Use a crimping tool to secure the butt splice on the Adapter Kit wire harness to the Torch Lead or Adapter Kit pilot wire from which the ring terminal was removed Check for a secure connection Slide the insulating sleeve over the butt splice Strain Relief Dome Nut Torch Control Connectors Torch Leads VA Assembly f NS Strain Relief Sleeve and Tie Wrap K hy Assembly Removed from Joined W
3. Manual Manuel 0 2953 THERMAL DYNAMICS un IT A THERMADYNE Company Kit D Adapteur De Torche 82 Benning Street West Lebanon NH 03784 USA Catalogue 7 3478 603 298 5711 www thermal dynamics com Instructions D Installation Informations G n rales No 7 3478 de kit d adapteur de cette d instructions de couverture dynamique de Thermal Le kit connecte les torches SL60 ou SL100 de 1Torch quip es des connecteurs d O2B ou le kit d adapteur d ATC a l quipement suivant e Miller Spectrum alimentation de l nergie 625 Pas l utilisation ce kit sur aucun autre quipement Pieces Fournies Le kit inclut Assembl e d adapteur comprenant des harnais de fil avec des connecteurs Passe fils Enveloppes de cravate utilisation comme n cessaire Instructions AVERTISSEMENTS ___ ___ O_o uo s _ QQ o e m_ z mes ps sh s _ Puissance d entree primaire de debranchement au systeme avant de commencer l installation Coup l offre et la purge de gaz en bas le systeme Seulement un technicien qualifi devrait ex cuter ce proc d Proc d Enlevez la couverture d alimentation d nergie par instructions du fabricant D branchement la torche originale par instructions du fabricant Glissi re en arri re la douille d isolation couvrant le fil pilote avec le terminal de languette d anneau sur le kit de fils de torche ou d adapteur d ATC Coupe le terminal d anne
4. au outre du fil pilote Bande en arri re d isolation approximativement 1 4 6 mm de l extr mit du fil Enlevez l enveloppe de cravate et le isolateur de deux fils connect s ensemble sur le kit de fils de torche ou d adapteur d ATC D branchement les deux fils jointifs Enlevez l crou de fixation du passe fils fourni dans ce kit Glissi re le passe fils sur les fils de kit de fils de torche ou d adapteur d ATC Passage les fins des fils de kit de fils de torche ou d adapteur d ATC par l ouverture d acces dans l alimentation d nergie Passage le passe fils fixant l crou au dessus des fils de kit de fils de torche ou d adapteur d ATC Utilisation l amp crou de passe fils bloqu le passe fils l alimentation d nergie Ne serrez pas le passe fils sur les fils Filet l adapteur de torche solidement sur le raccord de n gatif plasma de fils de torche ou de fils de kit d adapteur O2B Pas le mastic d utilisation Utilisation une prise de cl le raccord en laiton de kit d adapteur stationnaire tout en en utilisant une autre spire de cl les fils de torche ou raccord du kit O2B de l adapteur d ATC Ne trop serrez pas July 7 2003 7 Juilliet 2003 5 Manual Manuel 0 2953 9 Utilisation les connecteurs joignants de fil de connecter le harnais de fil de kit d adapteur aux fils de torche ou aux fils de kit d adapteur Examinez pour assurer les raccordements bloqu s 10 Utilisation
5. he locking nut to pull the connection together Do not use tools to secure the connection Torch Leads ATC Male Connector To Power Supply ATC Adapter Female Receptacle A 03627 Torch Connection Torch Leads with ATC Male Connector Power Supply with ATC Adapter 18 Check the torch for proper consumable parts me CAUTION The torch parts must correspond with the type of operation Refer to the Torch Manual for details 19 Connect primary input power Turn on the gas supply 20 Set proper gas pressure and flow per the Torch Instruction Manual 21 Test the system for proper operation July 7 2003 7 Juilliet 2003 3 Manual Manuel 0 2953 Pinout Diagram for Hand Torch with ATC Adapter ATC Male Connector ATC Female Receptacle Front View LT View Pilot I Pilot S 1 Black 1 Black PIP 5 Open LA N PIP to Large Pin FR 5 Open 6 Open ES Es o am 2 Saf Sat 2 cA Su 6 Open 7 Open se Q EZ lage Soe a a 8 Open NS Yj ao 4 en NAS Y 8 Open el Plasma w Plasma NOTE A 03708 Every effort has been made to provide complete and accurate information in this manual However the publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by errors or omissions in this Manual whether such errors result from negligence accident or any other cause July 7 2003 7 Juilliet 2003
6. ils solidement la main Ne trop serrez pas 15 Utilisation les enveloppes de cravate comme bloqu es n cessaire le harnais de fil de kit d adapteur en place dans l alimentation d nergie 16 R installez la couverture d alimentation d nergie par instructions du fabricant d alimentation d nergie 17 Pour des installations l aide de l adapteur d ATC alignez le connecteur m le de fils de torche avec le r ceptacle de femelle d adapteur d ATC Pouss e le connecteur m le dans le r ceptacle femelle Les connecteurs si la pouss e ainsi qu un peu de pression tr s Bloqu le raccordement en tournant l crou de verrouillage dans le sens des aiguilles d une montre jusqu ce qu il arr ts PAS l utilisation la traction d crou de verrouillage le raccordement ensemble Pas les outils d utilisation bloqu s le raccordement July 7 2003 7 Juilliet 2003 6 Manual Manuel 0 2953 Fils de Torche Au l Alimentation D Energie A 03627F Raccordement de torche fils de torche avec le connecteur m le d ATC alimentation d nergie avec l adapteur d ATC 18 V rifiez la torche pour les pi ces consommables appropri es ATTENTION Les pi ces de torche doivent correspondre l esp ce du fonctionnement R f rez vous au manuel de torche pour des d tails 19 Connectez la puissance d entr e primaire Spire sur l offre de gaz 20 Pression et flux de gaz appropri s d ensemble par manuel d instructi
7. ires e gt wie RN Strain Relief Securing Nut I oe gt To Power Supply ATC Adapter Negative Plasma Small lt Main Circuit peed Insulating Sleeve L 7 Board Butt Splice Pilot L an e on Pilot Lead Torch Adapter a To Power Supply Ring Terminal Gas Solenoid Assembly Removed from Pilot Lead Fitting 11 Arrange the Torch Adapter as shown 12 Insert the Adapter Kit fitting into the receptacle on the power supply solenoid assembly Press the fitting into the receptacle to seat it fully Check for a secure connection 13 Align the connectors on the Adapter Kit wire harness to the two mating receptacles on the power supply main circuit board Press the connectors firmly into the receptacle Check for a secure connection 14 Tighten the Strain Relief Nut onto the Strain Relief securely by hand Do not overtighten 15 Use the tie wraps as needed to secure the adapter kit wire harness in place within the power supply 16 Reinstall the Power Supply cover per the Power Supply manufacturer s instructions July 7 2003 7 Juilliet 2003 2 Manual Manuel 0 2953 17 For installations using the ATC Adapter align the torch leads male connector with the ATC Adapter female receptacle Push the male connector into the female receptacle The connectors should push together with a very small amount of pressure Secure the connection by turning the locking nut clockwise until it stops DO NOT use t
8. ons de torche 21 Test le syst me pour le fonctionnement appropri Diagramme de Pinout pour la torche de main avec l adapteur d ATC TORCHE DE MAINS Connecteur Male D ATC R ceptacle Femelle D ATC Vue de Face Vue de Face a LEA Pote bl Noir Noir 5 Ouverte LR BIP i au Gaulle E FR m ES 7 Be on 2 Orange PIP RS gt ON 5 t 6 owens ll E au Douille Petite le 3 Blanc 3 Blanc 7 Ouverte 4 aa Commutateur ar TEN XG 4 Vert au Douille Grande Ice 7 Ouverte 8 Ouverte GA Commutateur KA 4 8 Ouverte 4 Vert Qda p Commutateur Negatif Plasma au Goupille Petite ba er Hplas nd A 03708F 7 6 Ouverte ZA NOTE Tout effort a t fait de fournir des informations compl tes et pr cises en ce manuel Cependant l diteur n assume pas et ne d ment par ceci aucune responsabilit aucun usager pour aucune perte ou dommages provoqu s par des errors ou omissions en ce manuel si un tel r sultat d errors de la n gligence accident ou tout autre cause July 7 2003 7 Juilliet 2003 7 Manual Manuel 0 2953
9. un outil sertissant par replis bloqu le pissure sur le harnais de fil de kit d adapteur au fil pilote de kit de fil ou d adapteur de torche duquel le terminal d anneau a t enlev Examinez pour assurer un raccordement bloqu Glissi re la douille isolante au dessus du pissure Strain Relief Dome Nut Torch Leads Assembly Torch Control Connectors Strain Relief Sleeve and Tie Wrap os Assembly Removed from Joined Wires ee Connectors Disconnected ZN Y ZD rl Adapter Kit Strain Relief Re ene So _ SCH 1 Se Securing Nut Negative Plasma x lt Small Lead S Insulating Sleeve N ATC Adapter To Power Supply Main Circuit Board Butt Splice Pilot L a on Pilot Lead Torch Adapter a To Power Supply Ring Terminal Gas Solenoid Assembly Removed from Pilot Lead Fitting 11 Arrangez l adapteur de torche comme montr 12 Isolant le raccord de kit d adapteur dans le r ceptacle du sol noide d alimentation d nergie Pression le raccord dans la port e de r ceptacle il enti rement Examinez pour assurer un raccordement bloqu 13 Alignez les connecteurs sur le harnais de fil de kit d adapteur sur les deux r ceptacles joignants sur la carte principale d alimentation d nergie Pression les connecteurs fermement dans le r ceptacle Examinez pour assurer un raccordement bloqu 14 Serrez l crou de passe fils sur le passe f