61-340 #61-342 Digital Multimeter Instruction Manual Ranges
Contents
1. 61 340 61 342 EAL Digital Multimeter Instruction Manual ett PELD A eee OL D kMCHz ai a wW pmvAnF Power Off VQ a Hz 4 ND 6447 1 61 340 61 342 Ins 3 17 08 6 42 AM Page 1 A Read First Safety Information Understand and follow operating instructions carefully If this tester is not used in a manner specified by IDEAL protection provided by the product may be impaired AN WARNINGS To avoid possible electric shock personal injury or death follow these instructions e Do not use if meter appears damaged e Visually inspect the meter to ensure case is not cracked and back case is securely in place e Inspect and replace leads if insulation is dam aged metal is exposed or probes are cracked Pay particular attention to the insulation sur rounding the connector e Do not use meter if it operates abnormally as protection maybe impaired e Do not use during electrical storms or in wet weather e Do not use around explosive gas dust or vapor e Do not apply more than the rated voltage to the meter e Do not use without the battery and the back case properly installed e Remove the test leads from the meter before removing battery cap Do not attempt to repair this unit as it has no user serviceable parts e Disconnect power and discharge capacitors before testing resistance continuity diodes capacitance or temperature e Replace battery as soon as low battery i
2. cita originada en la venta e Ciclo de trabajo 15 s activado 15 min desactivado para 10 A MAX I IL LL Conmute para Circuito cerrado Circuito abierto AN ADVERTEN CIA Para evitar riesgos de elec trocuci n desconecte los cables de las puntas de oprimir para salir del modo Luz de fondo de fondo Xp La luz de fondo queda encendida por 10 s Conmute al rango de operaci n a lt 75 de H R Ambiente de 4 a 140 F 20 a 60 C almacenamiento a lt 80 de H R alt x ancho x prof Accesorios Cables de prueba TL 310 bater a de 9 Y incluidos Instrucciones de operaci n Certificaci n Cumple norma UL IEC EN 61010 1 61010 031 Cat IIl 600V cUbus C coe 0 Aislamiento doble de un producto IDEAL incluidas pero sin limi tarse a ellas las garant as impl citas de comercia oa ers bilidad y adecuaci n para un prop sito particular Retire el sop Continuidad audible i Peso 13 6 onzas 386 g se limita a lo indicado anteriormente E fabricante Tama o 7 0 x 3 5 x 1 9 no es responsable legalmente por la p rdida del Eo Pulse gt 1 s para luz 177 x89 x 48 mm uso del instrumento u otros da os y perjuicios incidentales o consecuentes gastos o p rdidas econ micas ni por ninguna reclamaci n de dichos da os y perjuicios gastos o p rdidas econ micas Las leyes estatales var an por lo que las limita ciones o exclusione
3. 1afin d viter les fausses lectures e Utilisez les bonnes bornes fonction et plage pour vos mesures e Se conformer avec toutes les exigences locales et nationales en mati re de s curit y compris l utilisation du mat riel de protection personnel ad quat ATTENTION Pour vous prot ger ayez le r flexe la s curit d abord e Les tensions d passant 30 V CA ou 60 V CC peuvent pr senter un risque d lectrocution il faut donc faire preuve de prudence e Utilisez un quipement de protection individu elle appropri comme lunettes de s curit masque facial gants isolants chaussures isol es et ou tapis isolants e Avant chaque utilisation Proc dez un essai de continuit et mettant les fils d essai en contact l un avec l autre afin de contr ler le fonctionnement de la pile et des fils d essai Utilisez la m thode de s curit en 3 points 1 V rifiez le fonctionnement du multimetre en mesurant une tension connue 2 Appliquez le multimetre au circuit en cours de contr le 3 Retournez a la tension active connue pour v rifier le bon fonctionnement e Nejamais se mettre la terre quand on proc de des mesures lectriques e Connectez le conducteur commun noir la terre avant d appliquer le conducteur d essai rouge sur la tension Commencez par d connecter le conducteur d essai rouge de la tension e Travaillez toujours avec un quipier e Quand on se sert des sondes t
4. 7 pi 2000 m Pr cision Pr cision nominale 23 5 C 73 41 F lt 75 H R Piles 9VDC NEDA 1604 Dur e de service 200 h 61 340 de la pile 150 h 61 342 Fusible 0 5A 500V F 340 10A 1000V F 341 Environnement de 0 40 C 32 F a 104 F fonctionnement a lt 75 d H R Environnement de 20 C 60 C 4 a 140 F stockage lt 80 d H R Poids 386g 13 6 02 Taille 10 cm x 18 75 cm x 6 25 cm 7 0 po x 3 5 po x 1 9 po Accessoires inclus Conducteurs de test TL 310 pile de 9 V mode d emploi Certification de Conforme UL 61010 1 s curit Complies with UL IEC EN 61010 1 61010 031 Cat IIl 600V c UL us C a 0 Double isolation L appareil a t valu et il est conforme la cat gorie d isolation Ill cat gorie de surtension Ill Degr de pollution 2 conforme la norme IEC 644 Pour une utilisation l int rieur Entretien Nettoyez le bo tier avec un chiffon humidifi avec du d tergent doux Ne pas utiliser de produits abrasifs ni de solvants Service et pi ces de rechange Aucune pi ce par l utilisateur En se ce qui concerne les pi ces de rechange ou les renseignements concernant l entretien d pannage se mettre en rapport avec IDEAL INDUSTRIES INC Au 1 877 201 9005 ou visitez notre site web www testersandmeters com Declaration de garantie Ce testeur est garanti l acheteur primitif contre tout vice de mati re ou de fa on
5. Basculer pour HZ Basculer pour AC Rouge Couper l alimentation disjoncter le circuit connecter le multim tre en s rie puis r tablir l alimentation AN AVERTISSEMENTS e V rifiez le fusible avant l essai Utilisez les bonnes position de commutateur et entr es de conducteurs Ne jamais tenter de mesurer le courant de circuits ou de mat riel dont le potentiel est sup rieur a 600 volts e Cycle de service 15 s sur marche 15 mn sur arr t pour 10 A MAXI Continuit sonore Ws APO I IL LILI Basculer pour Circuit ferm Circuit ouvert AVERTISSEMENT Commnez par couper l alimentation du circuit Test de diode gt Bad Diode Open Shorted Basculer pour 4 Mes In LALO Bonne diode Direct Inverse ZN AVERTISSEMENT Coupez l alimenta tion du circuit avant de v rifier la diode Temp rature Basculer pour C A AVERTISSEMENT Pour viter l lec trocution ne pas placez les conducteurs d essai ou le thermocouple sur une source de tension N ee Fr quence Hz Cycle de service Basculer pour cycle de service Remarque Sur les cuisuits parasit mettez le cadran sur V c a puis basculez le bouton Hz Remplacement de la pile et du fusible Retirer le support inclin y AN AVERTISSEM ENT Pour viter l lectrocu tion d connect
6. da ado hay piezas met licas expuestas o las sondas est n fisuradas Preste atenci n en particular al aislamiento que rodea los conectores e No use el instrumento si funciona en forma anor mal porque puede verse reducida la protecci n e No use el instrumento durante tormentas el ctri cas o con tiempo h medo e No use el instrumento cerca de gases explo sivos polvo o vapor e No aplique al instrumento voltajes superiores al nominal e No use el instrumento sin la bater a ni si la parte posterior de la cubierta no est instalada correc tamente e Retire los cables de prueba del circuito antes de desmontar la tapa de la bater a e No intente reparar esta unidad puesto que no tiene piezas reparables por el usuario e Desconecte la alimentaci n el ctrica y descargue los capacitores antes de medir resistencia con tinuidad diodos capacitancia o temperatura e Reemplace la bater a tan pronto aparezca el indi cador de bater a con poca carga a fin de evitar lecturas falsas e Use los terminales la funci n y el alcance apropiados para sus medidas e Cumpla los requisitos de seguridad locales y nacionales incluido el uso de equipos de pro tecci n personal apropiados Precauci n Para protegerse piense que La seguridad primero e Los voltajes superiores a 30 VCA o 60 VCC rep resentan un riesgo de electrocuci n por lo que debe trabajar con precauci n e Use equipos de protecci n personal a
7. pendant deux ans compter de la date d achat Durant cette p riode de garantie IDEAL INDUSTRIES INC son choix remplacera ou r parera l unit d fectueuse suite la v rification du d faut ou du disfonctioneme Cette garantie ne s applique pas aux fusibles aux piles ou aux dommages r sultant d une utilisation abusive de la n gligence d un accident d une r paration non autoris e d une modification ou d une utilisation d raisonnable de l instrument wane Toutes les garanties implicites r sultant de la vente d un produit IDEAL incluant sans y tre limit es les garanties implicites de valeur marchande et d adaptation une fin particuli re sont limit es aux conditions ci dessus Le fabricant ne sera pas tenu pour responsable de la perte d usage de l instru ment ni d autres dommages accessoires ou indi rects d penses ou pr judice financier ou de toute s r clamation s pour de tels dommages d penses ou pr judices Les lois des provinces varient donc les limitations et exclusions pr c dentes peuvent ne pas s appli quer dans votre cas Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir d autres droits qui varient d une province a l autre IDEAL INDUSTRIES INC Sycamore IL 60178 U S A Etats Unis 877 201 9005 Technical Hotline Linea directa de Soporte T cnico Ligne d assistance technique www idealindustries com www testersandmeters com ND 6447 1
8. rms calibrated 61 342 model is true rms sensing Accuracy Accuracy is specified as a percentage of the reading a fixed amount at 23 C 5 C 73 4 F 9 F less than 75 relative humidity Temperature Coefficient 0 1 times the applicable accuracy specification from 32 F to 64 F and 82 F to 122 F 0 C to 18 C 28 C to 50 C N ee Ranges amp Accuracies Overload Protection 750VAC rms 500mA 600V Fast Fuse 10A 1000V Fast Fuse 500mA 600V Fast Fuse 10A 1000V Fast Fuse 600V DC AC rms 600V DC AC rms 600V DC AC rms 600V DC AC rms 600V DC AC rms Accuracy 0 5 5 1 5 5 1 5 5 2 0 5 2 5 5 1 2 5 1 0 2 1 2 2 2 0 5 0 1 3 Sensitivity lt 1MHz 0 7Vrms gt 1MHZ 5Vrms CF gt 2 add 1 0 to accuracy Range amp Resolution 400 0m 4 000 40 00 400 0 V 400 0m 4 000 40 00 400 0 600 V 400 0 4000 yA 40 00 400 0 mA 4 000 10 00 A 400 0 4000 yA 40 00 400 0 mA 4 000 10 00 A 4 000k 40 00k 400 0k Q 400 0n 4 0001 40 00u F 400 0u 4000u F N T o Po Q 2 S Q Oo 2 S S o 2 e e Oo S 2 o Test current 140 6 mA and then open circuit voltage is 2 5VDC typical 10M for VAC amp VDC The beeper turns on lt 25Q and turns off at gt 1200 Function DC Voltage AC Voltage 40 400H2 DC Current AC Current Resistance Capacitance Frequency Duty Cycle Diode Check Continu
9. Made in China Fabricado en China Fabriqu en Chine
10. Note On noisy circuits turn dial to V then toggle Hz button Battery amp Fuse Replacement connect test leads before removing battery cover AN WARNING For continued protection against fire replace only with fuses of the speci fied voltage current and rupture speed ratings N ae Data Hold gt Press to hold present value in d isplay depress to release display Min Max a A ose Toggle for MAX MIN Min Max e I Hold for gt 1sec to exit mode O ay Hz FFC z O Press to deduct reference value depress to exit mode Backlight Press gt 1 sec for backlight 47 Backlight stays illuminated for 10 sec Toggle to manual range on following functions Volts Ohms Amps Hold for gt 1sec to exit mode Specifications General Features Display 3999 Count LCD 3 3 4 Digit Refresh Rate 2 5x sec Over range OL is displayed Polarity Automatic no indication for positive polarity Minus sign for negative polarity True RMS 61 342 only Auto Power Off After 10 minutes of non use Low Battery Jis displayed if battery voltage drops below operating voltage Altitude 6561 7 ft 2000m Accuracy Stated accuracy at 73 41 F 23 5 C lt 75 RH Batteries 9VDC NEDA 1604 Battery Life 200 hrs 61 340 150 hrs 61 342 Fuse 0 5A 500V F 340 10A 1000V F 341 Operating 32 to 104 F 0 to 40 C environ
11. ar ce dernier pourra tre compromise A AVERTISSEMENTS Se conformer aux directives suivantes pour viter tout risque d lectrocution de l sions person nelles ou de mort e Nutilisez pas le multim tre s il para t endom mage e Examinez le multim tre pour s assurez que son ALIUD 61 340 61 342 6 42 AM Page 29 bo tier n est pas fissur et que sa partie arri re est bien fix e Inspectez et remplacez les cordons si leur iso lation est endommag e le m tal expos ou les sondes craquel es Portez une attention partic uliere l isolant entourant les connecteurs e N utilisez pas le multimetre s il fonctionne de mani re anormale la protection qu il offre pou vant tre compromise e Nutilisez pas l appareil pendant des orages ou temps tres humide e N utilisez pas l appareil en pr sence de gaz poussi re ou vapeur explosifs e Soumettez pas le multim tre une tension sup rieure la tension nominale e Nutilisez pas sans la pile ou si l arri re du bo tier n est pas bien mont e Retirez les fils d essai du multim tre avant de retirer le capuchon de pile e Ne tentez pas de r parer cet appareil Il ne com porte aucune pi ce r parable par l utilisateur e D connectez l alimentation et d chargez les con densateurs avant de tester la r sistance la conti nuit les diodes la capacit ou la temp rature e Remplacez la pile d s que le t moin de pile est affich d
12. e de 32 F a 64 F y 82 F a 122 F 0 C a 18 C 28 C a 50 C N ee Alcances y exactitudes Protecci n contra sobrecarga 750 VCA ef Fusible de corte rapido de 500 mA 600 V Fusible de corte rapido de 10 A 1000 V Fusible de corte rapido de 500 mA 600 V de corte rapido 10 A 1000 V 600 V XC CA ef 600 V CC CA ef 600 V CC CA ef 600 V CC CA ef 600V DC AC rms 1 0 3 3 0 10 Sensibilidad lt 1 MHz 0 7 V ef gt 1 MHz 5V ef 400 0m 4 000 40 00 400 0 V 600 0V 400 0m 4 000 40 00 400 0 600 V 400 0 4000 LA 40 00 400 0 mA 4 000 10 00 A 400 0 4000 pA 40 00 400 0 mA 4 000 10 00 A 4 000k 40 00k 400 0k Q 400 0n 4 000p 40 004 F 400 0w 4000p F 8 gt LO N Q 2 2 o 2 o O _ oO D o gt P gt lt E co Oo ra Q _ o O en 2 pu _ Q O 10 00 100 0 1 000k 10 00k 100 0k 1 000M 10 00M Hz E sonido bip se activa a lt 250 y se desactiva a gt 1200 Alcance y resoluci n Voltaje de CA Corriente de CC Corriente de CA Capacitancia Frecuencia Comprobaci n de diodos Continuidad Temperatura Resistencia Se indica la exactitud del instrumento nicamente La exactitud del termopar agrega otro 2 5 a la lectura Impedancia de entrada 10MQ para VCA y VCC CF Factor de cresta gt 2 Agregue 1 a la exactitud Exactitud no disponible para capacitancia lt 10 nF Voltaje de CC N ae Vol
13. enez les doigts aussi loin que possible des pointes de sonde Symboles Risque d lectrocution Voir la carte d instructions ES Mat riel prot g par une isolation double ou renforc e Es Conforme aux directives de l UE Plages et pr cisions Convertisseur c a Le mod le 61 340 assure une d tection par calcul de moyenne le mod le 61 342 talonn avec des valeurs efficaces r elles assure une v ritable d tection avec des valeurs efficaces r elles Pr cision La pr cision est sp cif e sous la forme d un pourcentage de la lecture une quantit fixe 23 C 5 C 73 4 F 9 F moins de 75 d humidit relative Coefficient de temp rature 0 1 fois la sp cifi cation de pr cision applicable de 0 C 18 C 28 C 50 C 32 F 64 F et 82 F 122 F Plages et pr cisions Protection contre la surcharge Plage et r solution 400 0m 4 000 40 00 400 0 V Fonction Tension c c valeurs efficases r elles Tension c a 400 0m 4 000 40 00 400 0 600 V N ee 500mA 600 V Fusible rapide 400 0 4000 pA 40 00 400 0 mA Courant c c 10mA 1000 V Fusible rapide 4 000 10 00 A N ae 400 0 4000 yA 500mA 600 V Fusible rapide 40 00 400 0 mA Courant c a 10mA 1000 V Fusible rapide 4 000 10 00 A 600 V c c c a valeurs efficases r elles 4 000k 40 00k 400 0k Q R sistance 3 0 10 600 V c c c a valeurs efficases r e
14. ez les conducteurs de test avant de retirer le couvercle de pile AVERTISSEMENT Pour une protection continue contre l incendie ne remplacez que par un fusible pr sentant les caract ristiques de ten sion d intensit et de rapidit d action sp cifi es dk ae R tention de donn es Appuyer pour retenir la valeur actuelle sur l affichage appuyer pour lib rer l affichage Mini Maxi Lara Basculer pour LES wa Min Max 1111 e POL Appuyer pen dant gt 1s pour quitter le mode Basculer pour le mode relatif Appuyer pour d duire la valeur de r f rence appuyer pour quitter le mode R tro clairage Appuyer gt 1 s pour le r tro clairage f Le r tro clairage demeure allum pendant 10 s Basculer vers la plage manuelle sur les fonctions suivantes Volts Ohms Amperes pour quitter le mode Specifications Caract ristiques g n rales Affichage Affichage a cristaux liquides d compte jusqu 3999 3 3 4 chiffres Fr quence de 2 5 fois s rafra chissement D passement OL est affich Polarit Automatique pas d indication de polarit positive Signe moins pour la polarit n gative Valeurs efficaces 61 342 uniquement vraies Arr t automatique Au bout de 10 minutes de non utilisation Pile d charg e Est affich si la tension de la pile descend au dessous de la tension de fonctionnement Altitude 6561
15. ity Temperature Accuracy not available for lt 10nF capacitance Accuracy is stated for meter only Thermocouple accuracy adds another 2 5 to reading Input Impedance N ae AC Voltage V Toggle for Frequency gt 20 of ND 6447 1 61 340 61 342 Ins 3 17 08 Resistance Q MN WARNING De energize circuit before a Capacitance taking resistance measurement E Toggle for 4 A WARNING De energize circuit and discharge capacitor before taking capaci tance measurement Measuring time lt 15sec for lt 400yuF lt 1min for lt 4000uF 6 42 AM Page 8 AC DC Current A Turn power off break circuit insert meter in series then turn power back on AN WARNINGS e Check fuse for continuity before testing Use the proper switch position and lead inputs Never attempt to measure current on circuits or equipment with more than 600 volts potential e Duty cycle 15sec ON 15min OFF for 10A MAX Audible Continuity I IL LIL o Toggle for MN WARNING De energize circuit first Diode Test gt Bad Diode A WARNING De energize circuit before checking diode Temperature Toggle for C A WARNING To avoid electric shock do not place test leads or thermocouple on a voltage source N Sula Frequency Hz Duty Cycle Toggle for Duty Cycle
16. l o mano de obra Rojo voltaje de operaci n por dos a os contados a partir de la fecha de ne Altitud 6561 7 pies 2000 m compra Durante este periodo de garantia IDEAL Desconecte la alimentacion inserte el instrumento ee ap ADVERTENCIA Corte la corriente en en serie y vuelva a conectar ADVERTENCIA Corte la corriente en ne oe do a gee f M odo rel ativo 73 41 F 23 5 C IDEAL reemplazar o reparar la unidad defectuosa los circuitos antes de tomar medidas de los circuitos antes de comprobar el diodo ict ficaci n del delecto o talla Es resistencia AN ADVERTENCIAS Nota En los circuitos ruidosos gire el cuad HR lt 75 lodo e Revise el fusible antes de realizar la rante a VAC y luego conmute el bot n Hz Bater a 9 VCC NEDA 1604 garant a no se aplica a fusibles bater as o da os manu Capacitancia prueba Temperatura y onmute para Vida til de 200 hr 61 340 que sean consecuencia de abusos negligencia eoa Use la posici n del conmutador y las Reemplazo de bater a y fusible modo relativo la bater a 150 hr 61 342 accidentes reparaci n sin autorizar alteraciones o entradas de cables de prueba adecuadas Pulse para Fusible 0 5A 500V F 340 uso no razonable del instrumento e Nunca intente medir corriente en circuitos A V F o equipos con un potencial de m s de Conmute para deducir el valor LON ee a P p C de referencia Ambiente 32 a 104 F 0 a 40 C Cualquier garant a impl
17. lles 400 0n 4 0004 40 00u F 400 01 4000u F 600 V c c c a valeurs efficases r elles 0 1 3 Sensibilit lt 1 MHz 0 7 V valeurs efficaces r elles gt 1 MHZ 5 V valeurs efficaces r elles 10 00 100 0 1 000k 10 00k 100 0k 1 000M 10 00M Hz Fr quence 0 1 99 9 Cycle de service Contr le de diod 600 V c c c a 35 C O O 5 SS uN SO _ wo O a o gt LO N D TD 8 se O gt 5 o 5 O O TD Z 2 wn C O 25 A 5 o lt 2 O a S 5 O L avertisseur sonore se d clenche lt 25Q et s arr te gt 1200 Continuit 58 1500 F 50 800 C Temp rature La pr cision n est pas disponible pour la capacit de lt 10 nF La pr cision est nonc e pour le multim tre uniquement La pr cision du thermocouple ajoute 2 5 la lecture Imp dance d entr e 10 MQ pour V c a V c c FC facteur de cr te gt 2 Ajouter ala pr cision Tension c a V ND 6447 1 61 340 61 342 Ins 3 17 08 R sistance J N AVERTISSEMENT Coupez l alimenta tion du circuit avant de mesurer la r sis tance Capacit 4 Toggle for 4 M AVERTISSEMENT Coupez l alimenta tion du circuit et d charger le condensa teur avant de mesurer la capacit Temps en mesure lt 15s pour lt 400 pF lt 1mn pour lt 4000 UF 6 42 AM Page 36 Courant c a c c A
18. ment at lt 75 RH Storage 4 to 140 F 20 to 60 C environment at lt 80 RH Weight 13 6 oz 386g Size 7 0 H x 3 5 W x 1 9 D 177mmHx89mmWx48mmD Accessories Test leads TL 310 9V battery Included Operating Instructions Safety Complies with UL IEC EN 61010 1 Certification 61010 031 Cat IIl 600V Uus C ea El Equipment protected by double insulation Instrument has been evaluated and complies with insulation category Ill overvoltage category III for measurements performed in the building installation Pollution degree 2 in accordance with IEC 644 Indoor use Maintenance Clean the case with a damp cloth and mild deter gent Do not use abrasives or solvents Service and Replacement Parts No user serviceable parts For replacement parts or to inquire about service information contact IDEAL INDUSTRIES INC at 1 877 201 9005 or visit our website www testersandmeters com Warranty Statement This tester is warranted to the original purchaser against defects in material and workmanship for two years from the date of purchase During this warranty period IDEAL INDUSTRIES INC will at its option replace or repair the defective unit sub ject to verification of the defect or malfunction This warranty does not cover fuses batteries or damage from abuse neglect accident unautho rized repair alteration or unreasonable use of the instrument Any implied warranties arising ou
19. ndicator Jappears to avoid false readings e Use the proper terminals function and range for your measurements e Comply with local and national safety requirements including the use of appropriate personal protective equipment CAUTION To protect yourself think Safety First Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution e Use appropriate personal protective equipment such as safety glasses face shields insulating gloves insulating boots and or insulating mats e Before each use Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads Use the 3 Point Safety Method 1 Verify meter operation by measuring a known voltage 2 Apply meter to circuit under test 3 Return to the known live voltage again to ensure proper operation e Never ground yourself when taking electrical measurements e Connect the black common lead to ground or neutral before applying the red test lead to potential voltage Disconnect the red test lead from the voltage first e Always work with a partner e When using the probes keep fingers as far behind the probe tips as possible Symbols Risk of electric shock See instruction card Pee Do meet O Equipment protected by double or reinforced insulation Battery o AC measurement Conforms to EU directives Ranges amp Accuracies AC Converter 61 340 model is averaging sensing
20. propiados tales como gafas de seguridad m scaras faciales guantes calzado y o alfombras aislantes e Antes de cada uso Realice una prueba de continuidad poniendo en contacto los cables de prueba para verificar el funcionamiento de la bater a y los cables Use el m todo de seguridad de 3 puntos 1 Verifique el funcionamiento del instrumento midiendo un voltaje conocido 2 Aplique el instrumento al circuito en prueba 3 Vuelva al voltaje conectado conocido para asegu rarse de que el funcionamiento es correcto e No se conecte a tierra cuando tome medidas el ctricas e Conecte el cable com n negro a tierra antes de aplicar el cable de prueba rojo al voltaje Desconecte primero el cable de prueba rojo del voltaje e Trabaje siempre con un compa ero e Cuando use las sondas mantenga los dedos tan lejos de las puntas de las mismas como sea posible S mbolos Riesgo de electrocuci n Vea la tarjeta de instrucciones m MedidadeCO Equipo protegido por aislamiento doble o reforzado T uwe Alcances y exactitudes Conversor de CA El modelo 61 340 es con sensado de promedio calibrado en valor eficaz el modelo 61 342 es con sensado de valor eficaz verdadero Exactitud La exactitud se especifica como un porcentaje de la lectura una cantidad fija a 23 C 5 C 73 4 F 9 F con menos del 75 de humedad relativa Coeficiente de temperatura 0 1 veces la especificaci n de exactitud aplicabl
21. s anteriores pueden no apli carse en su caso Esta garant a le da derechos legales espec ficos y puede tener otros derechos manual en las sigu E instrumento ha sido evaluado y cumple con la cae prueba antes de abrir la tapa del compartimiento ientes funciones categoria III de aislamiento categor a Ill de que var an de estado a estado J N ADVERTENCIA Corte la corriente en A ADVERTENCIA Para evitar riesgos de de la bater a Voltage Resistencia sobrevoltaje Grado 2 de contaminaci n de acuerdo los circuitos y descarge el capacitor antes electrocuci n no coloque los cables de MN ADVERTENCIA Para lograr una protecci n Corriente con IEC 644 Uso en interiores de tomar medidas de capacitancia Tiempo de medida lt 15s para lt 400 uF lt 1min para lt 4000 pF prueba o la termocupla en una fuente de continua contra incendios reemplace el fusible voltaje s lo por uno del voltaje corriente y velocidad de ruptura especificados N ADVERTENCIA Corte la corriente en el Retenga por gt 1 s circuito primero para salir del modo N ae ND 6447 1 61 340 61 342 Ins JEA Multimetre num rique Manuel d instructions kata ue son A A diet eo ddbg Auto Power Off VO 1 Hz 4 A Lire en premier Assimilez et se con formez scrupuleusement aux instructions d utilisa tion En cas d utilisation de cet appareil d une facon non sp cifi e par IDEAL la protection offerte p
22. t of the sale of an IDEAL product including but not limited to implied warranties of merchantability and fitness for a par ticular purpose are limited to the above The man ufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or eco nomic loss State laws vary so the above limitations or exclu sions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state lt ND 6447 1 61 340 61 342 Ins 3 17 08 g 61 340 Q 120 461 342 IDEAL Multimetro digital Manual de Instrucciones SELECT HOLDA O Hz F C Q a 4 True RMS Power Off V Q gt a Hz 4 6 42 AM Page 15 A Lea primero Informacion de seguridad Asegurese de entender y seguir cuidadosamente las instrucciones de operaci n Si el equipo se utiliza en una forma no especificada por IDEAL la protecci n que proporciona puede verse reducida N ADVERTENCIAS Para evitar posibles riesgos de electrocuci n lesiones o la muerte siga estas instrucciones e No use el instrumento si el mismo parece estar da ado e Inspecci nelo visualmente para asegurarse de que la cubierta no est fisurada y que la parte trasera de la misma est firmemente colocada en su sitio e Inspeccione y reemplace los cables si el ais lamiento est
23. taje de CC V Conmute para Hz gt 20 del rango Power Off VQ ND 6447 1 61 340 61 342 Ins 6 42 AM Page 22 N Sula Resistencia Q Corriente de CA CC A Prueba de diodos Frecuencia Hz Retenci n de datos Especificaciones Mantenimiento A i Bad Diode i Ci cl o de tra baj 10 Y Caracteristicas generales Limpie la cubierta con un pa o h medo y un ey isos also Pantalla LCD de 3999 unidades detergente suave No use abrasivos ni solventes RSR i va ae E para retener el di Conmute wioracual dela bie is 2 5 s Servicio y piezas de re puesto ara Hz i actualizacion No hay piezas reparables por el usuario PG Paton Laka Fuera de rango Aparece OL P P LULU ee a a ae ee Conmute boocol MTS AN la pantalla Foangad sedi As Para obtener informaci n sobre piezas de repuesto o para averiguar acerca del servicio para CA 4 z Signo menos para J Min Max comun quese con IDEAL INDUSTRIES INC al AA polaridad negativa 1 877 201 9005 o visite nuestro sitio web TIE mI Valor eficaz 61 342 nicamente Conmute para de www testersandmeters com fl Min Max Apagado Despu s de 10 minutos sin uso G ti Retenga por automatico arantia gt 1 s para salir Bater a con aparece si el voltaje Se garantiza este instrumento al comprador origi del modo poca carga de la bater a cae por debajo del nal contra defectos de materia