Home
        9848EFDA IM.cdr - Taylor Precision Products
         Contents
1.    General Operation    1  Sterilize the metal probe by inserting it into an appropriate  solution such as boiling water for several minutes     2  Press  On OFF  to turn the unit on  Press again for a 5  second backlight  Press    F   C  to select temperature  scale  Note  To save battery life  this unit has an AUTO   OFF feature that turns the instrument off after 5 minutes if  no buttons are pressed and the temperature reading is  lower than 122  F  50  C   Press and hold    On OFF    to  turn off manually     3  The sensor is located in the probe tip for a quick response  and accurate reading  When ready to test the  temperature  insert thermometer probe into the center of  the product for an accurate temperature measurement   The LCD will stabilize when reading is complete   approximately 10 seconds      4  Hold Feature  Press the  Hold  button and the  temperature will be held  the  HOLD  icon will appear    Press again to release     5  Max Feature  Press the  Max s  button once to read the  maximum temperature that the probe has reached  the  word    Max    will appear   Press the  Max s  button again  to read the minimum temperature that the probe has  reached  the word    Min    will appear   Press  Max s  a  third time to return to the current temperature reading   Otherwise the unit will automatically return to the current  temperature reading after 10 seconds     6  To avoid burns near heat  snap the pocket sleeve onto the  opposite end of the thermometer and use
2.  1 grado   F  0 5 C     4  Para ingresar la temperature recalibra  presi  nelo sin soltar  durante 5 segundos el bot  n    SET     La pantalla LCD dar   vuelta  a verde  Aparecer   un patr  n de rayitas             luego    OK       5  Despu  s de 2 segundos  la unidad volver  n a modo normal    6  Para regresar a la temperature recalibra predeterminada  quite la  bater  a para 1 minuto y despu  s reemplazar     Nota  Si no    presiona ning  n bot  n en 30 segundos  la unidad  volver  n autom  ticamente a modo normal      Caracter  stica antimicrobiana    La funda y la carcasa Safe T Guard   de Taylor incorporan un  compuesto qu  mico no t  xico que inhibe el crecimiento de  agentes pat  genos nocivos  lo cual minimiza la contaminaci  n  cruzada  Es importante limpiar y desinfectar totalmente su  term  metro despu  s de cada uso        
3.  abus  utilisation commerciale ou r  glage interdit et ou  r  paration interdite  Si ce produit doit   tre r  par    ou remplacement     notre discr  tion   ne le retournez pas au d  taillant  Veuillez l emballer  avec soin et le retourner    frais pr  pay  s avec la facture du magasin  indiquant la date d achat et une note expliquant la raison du retour     l adresse suivante  Il n y a aucune garantie expresse sauf celle indiqu  e  pr  c  demment  Cette garantie vous donne des droits pr  cis  mais vous  pouvez aussi avoir d autres droits qui varient d une juridiction    l autre   Pour de l information suppl  mentaire sur le produit ou sur la garantie     l ext  rieur des     U  veuillez nous contacter par www taylorusa com    Fabriqu   en Chine selon nos sp  cifications exactes        Garant  a limitada por un a  o    Taylor   garantiza este producto contra defectos en los materiales   escepto las bater  as  y en la mano de obra durante 1  un  a  o a partir  de la fecha de compra original  No cubre da  os ni desgastes que sean  consecuencia de accidentes  uso inadecuado  abuso  uso comercial  ni  ajustes y o reparaciones no autorizadas  Si este producto requiere  mantenimiento  o cambio a nuestro entender   no la devuelva al  vendedor minorista  S  rvase empacar el art  culo cuidadosamente y  env  elo con el franqueo pagado  junto con el recibo de la tienda en el   ue aparezca la fecha de compra y una nota explicando el motivo de la  devoluci  n  No existen garant  as expres
4.  as a handle        NOTE  please recycle or dispose of batteries per local  regulations    WARNING  Batteries may pose a choking hazard  As with all  small items  do not let children handle batteries  If swallowed   seek medical attention immediately    PRECAUTION  Do not dispose of batteries in fire  Batteries  may explode or leak  Remove the battery if the thermometer  will not be used for a long period of time     Fonctionnement g  n  ral       1  St  rilisez la sonde m  tallique en l ins  rant dans une solution  appropri  e  comme de l eau bouillante  pendant plusieurs  minutes    2  Appuyez sur le bouton   On Off    marche arr  t  pour mettre  l appareil en marche  Appuyez    nouveau pour un  r  tro  clairage de 5 secondes  Appuyez sur le bouton     F   C    pour choisir la plage de temp  rature  Remarque   Pour  conserver la pile  cet appareil comprend une fonction   AUTO   OFF    arr  t automatique  qui l appareil s   teindra  automatiquement apr  s environ 5 minutes si aucune touche  n est enfonc  e et la temp  rature est moins   lev  e que 122  F   50  C   Appuyez et gardez   On Off   pour mettre hors tension  manuellement    3  Le capteur se trouve sur le bout de la sonde pour une r  ponse  rapide et un relev   exact  Lorsque vous   tes pr  t    tester la  temp  rature  ins  rez la sonde du thermom  tre au centre du  produit pour un relev   de temp  rature exact  L ACL se  stabilisera    la fin du relev    environ 10 secondes     4  Fonction de Hold  retenue   Appuy
5.  de instrucciones    Taylor Precision Products  Inc   2220 Entrada Del Sol  Suite A  Las Cruces  New Mexico 88001 USA  www taylorusa com               Specifications   Sp  cifications   Especificaciones   Range   Plage   Rango     40  F to 450  F   40  C to 230  C    Accuracy   Exactitude   Precisi  n        3 6  F  2 0  C     40    14  F   40      10  C        1 8  F  1 0  C    14     212  F   10   e 100  C        1  F  0 5  C    140     180  F  60     82  C        3 6  F  2 0  C    212     300  F  100     149  C        5 4  F  3 0  C    300      400  F  149     204  C        7 2  F  4 0  C    400      450  F  204      230  C   Resolution   R  solution   Resoluci  n    0 1  F or   C up to 199 9    above 1  F and   C    0 1   F ou   C jusqu    199 9     au dessus de 1   F et   C    0 1  F o   C hasta 199 9    por encima de 1  F y   C    Auto Shut off   Arr  t automatique   Apagado autom  tico   To conserve battery power   Pour conserver le courant de pile   Para conservar la energ  a de la bateria    Response Time   Temps de r  action    Tiempo de respuesta    5 seconds to stabilization   5 secondes pour la stabilisation   5 segundos para la estabilizaci  n    Battery   Pile   Bater  a   1 CR2032 lithium  1 pile CR2032 au lithium  1 de litio CR2032             Reemplazo de la bater  a    El term  metro funciona con una bater  a de litio CR2032  Si la unidad  no encender   para usarla por primera vez  retirez y reinserte la  bater  a  Cambie la bater  a cuando la pantalla se v
6.  non toxique qui pr  vient la croissance de  pathog  nes dangereux ce qui r  duit la contamination crois  e  ll est  important de bien nettoyer et d  sinfecter votre thermom  tre apr  s  chaque utilisation        kd    One Year Limited Warranty    This product is warranted against defects in materials or workmanship   excluding batteries  for one  1  year for the original purchaser from  date of original purchase  It does not cover damages or wear resulting  from accident  misuse  abuse  commercial use  or unauthorized  adjustment and or repair  Should this product require service  or  replacement at our option  while under warranty  do not return to  retailer  Please pack the item carefully and return it prepaid  along with  store receipt showing date of purchase and a note explaining reason  for return  There are no express warranties except as listed above  This  warranty gives you specific legal rights  and you may have other rights  which vary from state to state  For additional product information  or  warranty information outside the USA  please contact us through  www taylorusa com     Made to our exact specifications in China        Garantie limit  e d un an   Taylor   garantit que ce produit     l exclusion des piles est libre de tout  d  faut de mat  riaux ou de main d   uvre pour une p  riode d un  1  an  pour l acheteur original    partir de la date d achat original  Elle ne couvre  pas les dommages ou l usure suite    un accident  une mauvaise  utilisation  tout
7. as excepto las enunciadas  anteriormente  Esta garant  a le otorga derechos legales espec  ficos y es  posible que usted tenga otros derechos que var  en de un estado a otro   Para obtener informaci  n adicional sobre el producto  o informaci  n de  la garant  a fuera de los EE UU   s  rvase contactarnos a trav  s de  www taylorusa com     Fabricado en China seg  n nuestras especificaciones  exactas  9848EFDA 10 14 WC    Funcionamiento general    1  Esterilice la sonda de metal introduci  ndola en una soluci  n  adecuada  tal como agua hirviendo  durante varios minutos   2  Presione el bot  n    On Off     comenzar detener  para  encender la unidad  Presione nuevamente para una luz  posterior de 5 segundos  Presione el bot  n    F   C  para  seleccionar la escala de temperatura  Nota  para ahorrar vida    til de la bater  a  esta unidad cuenta con una caracter  stica de  apagado autom  tico que la unidad se apage  autom  ticamente despu  s de 5 minutos si no presiona ning  n  bot  n y la temperatura es menor que 122 F  50  C   Presione y  mantenga presionado    On Off    para apagar en forma  manual   El sensor est   ubicado en el extremo del term  metro para una  r  pida respuesta y una lectura precisa  Cuando est   listo para  tomar la temperatura  introduzca el sensor del term  metro en el  centro del producto para una medici  n precisa de la temperatura   LCD se estabilizar   cuando la lectura est   completa   aproximadamente 10 segundos    Funci  n HOLD  mantener   Presi
8. ez sur le bouton   HOLD     retenue  et la temp  rature sera conserv  e  le ic  ne   HOLD    appara  tra   Enfoncez    nouveau pour d  gager    5  Fonction de Max  Appuyez sur le bouton   Max A   maximum   pour lire la temp  rature maximum que la sonde a atteint  le  mot    Max    appara  tra   Appuyez    nouveau sur le bouton    Max      pour lire la temp  rature minimum que la sonde a  atteint  le mot    Min    appara  tra   Appuyez    nouveau sur le  bouton   Max      pour revenir    l affichage de temp  rature  actuelle  Sinon l appareil passera automatiquement     l affichage de temp  rature actuelle apr  s 10 secondes    6  Pour   viter les br  lures pr  s de la chaleur  enclenchez le  manche de pochette sur l extr  mit   oppos  e du thermom  tre et  utilisez comme poign  e        NOTE  pour le recyclage ou la mise au rebut des piles  assurez   vous de respecter les dispositions r  glementaires de votre localit       AVERTISSEMENT  les piles peuvent pr  senter un risque de  suffocation  Comme avec tous les petits objets  ne laissez pas les  enfants manipuler les piles  En cas d ingestion  consulter  imm  diatement un m  decin     ATTENTION  Ne jetez pas les piles us  es dans le feu afin d   viter  tout risque d explosion ou de fuite  Veillez    retirer la pile de  l appareil si vous envisagez de ne pas l utiliser pour une p  riode  prolong  e     Pa       Folds    Battery Replacement       The thermometer operates on 1 CR2032 lithium battery  If the  unit does not turn 
9. ill tum green  A          pattern  appears  then    OK       5  After 2 seconds  the unit will return to normal mode    6  To restore the default calibration temperature  remove the battery  for 1 minute and then replace it   Note  If no buttons are pressed  for 30 seconds  the unit will automatically return to normal mode      Antimicrobial Feature       Taylor s Safe T Guard       sleeve and housing incorporates a non   toxic chemical compound that inhibits the growth of harmful  pathogens  which minimizes cross contamination  lt is important to  thoroughly clean and disinfect your thermometer after each use     Remplacement de pile    Le thermom  tre fonctionne avec 1 pile CR2032 au lithium  Si l appareil   n allumera pour la premiere utilisation  retirez et r  ins  rer la pile    Changez la pile lorsque l affichage faiblit  Pour remplacer la pile    1  Ouvrez le compartiment de piles en tournant le couvercle de la   orte du compartiment de piles    l arri  re du thermom  tre dans  e sens antihoraire    l aide d une pi  ce de monnaie dans la fente    2  Retirez la vieille pile et ins  rez en une nouvelle  avec le signe        vers le haut    3  Fermez le compartiment  Assurez vous que le joint torique est  assis autour de l ouverture pour maintenir la fonction   tanche   Remarque  Si la porte de piles n est pas ferm  e correctement   l eau pourrait p  n  trer dans le compartiment et l appareil  fonctionnerait mal     Calibrage    Si recalibrage est n  cessaire  pour les me
10. illeurs r  sultats calibrera dans  une plage de temperature le plus utilis  e g  n  ralement  Utilisez  toujours une source fiable comme point de r  f  rence en calibrant  Si  une temp  rature v  rifi  e de r  f  rence ne peut pas   tre r  alis  e dans la  plage d utilisation  calibrez alors dans un bain de glace tel qu indiqu       l   tape 1    1  Suspendez la sonde    au moins 1 po  2 54 cm  dans une    barbotine   de glace concass  e et d eau  32   F 0   C  pendant au  moins 30 secondes    2  Appuyez et gardez enfonc   sur le bouton   SET    r  gler  pendant 5  secondes  Le mot   SET   appara  tra  Puis appuyez sur   Max A   et    Hold Y   en m  me temps pour entrer dans le mode de r  glage de  la temp  rature  L ACL tournera le rouge  L affichage de temp  rature  actuelle clignote    3  Appuyez sur   Max A   ou   Hold W   pour augmenter r  duire la  temp  rature d un degr     F  0 5   C     4  Pour entrer la temp  rature recalibrera  appuyez et gardez enfonc    sur le bouton    SET     L ACL tournera le vert  Un motif                  appara  tra  puis    OK         Apr  s 2 secondes  l appareil reviendra    mode normal      Pour revenir    la temp  rature recalibrera par d  faut  retirez la pile  pour 1 minute et r  ins  rer la pile   Remarque  Si aucune touche n est  enfonc  e pendant 30 secondes  l appareil reviendra  automatiquement    mode normal         ou    Fonction antimicrobienne    Le manchon et bo  tier Safe T Guard   de Taylor incorpore un  compos   chimique
11. on for first use  remove and then reinstall the  battery  Change the battery when the display becomes dim  To  replace battery    1  Open the battery compartment by turning the battery  compartment door cover on the back of the thermometer  counterclockwise  using a coin in the slot    2  Remove used battery and insert new one  with the     sign  facing up    3  Close the compartment  Make sure the o ring is seated around  the opening to maintain waterproof feature  Note  If battery  door is not closed properly  water can get into the  battery compartment causing the unit to malfunction     Calibration    If recalibration is necessary  for best results calibrate within the  temperature range most commonly used  Always utilize a reliable  source as a benchmark when calibrating  If a verified reference  temperature cannot be achieved in the usage range  then calibrate in  an ice bath as described in Step 1    1  Suspend probe at least 1    into a  slush  of crushed ice and water   32  F  for at least 30 seconds  Keep the probe from touching the  container bottom    2  Press and hold the    SET    button for 5 seconds  The word    SET    will  appear  Then press  Max A  and  Hold w  at the same time to  enter Temperature Setting mode  The LCD will turn red  The current  temperature blinks    3  Press  Max A  or  Hold WY  to increase decrease the  temperature by 1  F  0 5  C    4  To enter the recalibrated temperature  press and hold the    SET     button for 5 seconds  The LCD w
12. one el bot  n    HOLD     mantener   y la temperatura se mantendr   en pantalla  aparecer   el   cona     HOLD      Presi  nelo nuevamente para volver a medir   6  Funci  n Max  m  xima  Presione el bot  n    Max W    para leer la  temperatura m  xima que la sonda ha alcanzado  aparecer   la  palabra    Max      Presione nuevamente el bot  n    Max W    para  leer la temperatura m  nima que la sonda ha alcanzado   aparecer   la palabra    Min      Presione nuevamente el bot  n     Max V    para volver a la pantalla de la lectura actual de la  temperatura  De lo contrario  la unidad cambiar    autom  ticamente a la pantalla de la lectura actual de la  temperatura despu  s de 10 segundos   Para evitar quemaduras cerca del calor  tire la funda hacia el  extremo opuesto del term  metro y util  cela como manija        a    5    7        NOTA  Por favor  recicle o deseche las bater  as con las  regulaciones locales     ADVERTENCIA  Las bater  as pueden representar un peligro de  asfixia  Como con todos los art  culos peque  os  no deje que los  ni  os manipulen las bater  as  Si se ingiere  busque atenci  n  m  dica inmediata    PRECAUCI  N  No tire las bater  as al fuego  Las bater  as pueden  explotar o tener p  rdidas  Retire la bater  a si el term  metro no se  utilizar   por un largo tiempo     98483EFDA    TAYLOR     Waterproof Digital Thermometer    Thermom  tre num  rique    tanche    Term  metro digital      prueba de agua  Instruction Manual   Manuel d instructions Manual
13. uelva borrosa  Para  reemplazar la bater  a    1  Abra el compartimiento de la bater  a girando hacia la izquierda la  tapa de la puerta del compartimiento de la bater  a en la parte  trasera del term  metro  usando una moneda en la ranura    2  Quite la bater  a e introduzca una nueva  con el signo     hacia  arriba    3  Cierre el compartimiento  Aseg  rese de que el anillo en O est    apoyado alrededor de la abertura para mantener la caracter  stica  a prueba de agua  Nota  si la puerta del compartimiento no  est   correctamente cerrada  puede entrar agua en el  mismo haciendo     Calibraci  n    Si es necesario recalibrar  para mejores resultados calibre en el  rango de la temperature m  s usada  Siempre utilice una fuente  confiable come punto de referencia cuando calibre  Si una  temperature verificada no puede ser obtenida en el rango de mayor  uso  entonces calibre en un ba  o de hielo seg  n lo descrito en el  paso 1     1  Suspenda la sonda al menos 1     2 5 cm  en una mezcla de hielo y  agua  32  F   0  C  durante al menos 30 segundos  Evite que la  sonda toque el fondo del recipiente     2  Presi  nelo sin soltar durante 5 segundos el bot  n    SET      configuran Aparecer   la palabra    SET     Luego presione los  otones  Max    y  Hold W  a la vez para ingresar al modo de  definici  n de la temperature  La pantalla LCD dar   vuelta a rojo   La temperatura actual parpadea     3  Presione los botones Max A  o  Hold Y  para aumentar o  disminuir la temperature en
    