         Contents
1.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            LILILILILILILILILILILILILILILILILILILILI                               3 3 8in   85       Air Cooled   59 1 16in   1500    Water Cooled   53 3 4in   1365          Refroidissement    air Refroidissement    eau  MODELE du S  CHEUR TDF210   TDF285   TDF340   TDF210   TDF285   TDF340  D  bit nom  d air 1  scfm     NI min     Nm3 h              Point de ros  e 1   Temp  rature ambiante nominale    F     C    Temp  rature ambiante max   F     C   Temp  rature ambiante minimum    F     C  34 1   Temp  rature nominale air entr      F     C  100   38   Temp  rature max  air entr      F     C  113   45   Pression nominale air e
2.                                                                                                                                                                                                                                                                                                             Oooo     D   m       D   m  e   m   01  D        01  D  IL   IL                                                                                                                                                                        000000000000  LICICICICIEICICICIETETES                                                       LILICICICILILILILILIEIE   LICICICICILILILILILIEIEI                                                       0000900002120  0000990000220  0000900002120  0000990000220  0000990000220  0000900002120  0000900002122  0000900002210  0000900002120  9000090000220  0000900000020  0000090000000                                                                                    0000000000220  0000090000220  0000200022120                                                              000000000000001                   Air Cooled   68 7 8in   1750  Water Cooled   63 5 8in   1615          AirCooled WaterCooled  TDF420   TDF520   TDF680   TDF420   TDF520   TDF680                   DRYER MODEL  Air flow rate at nominal condition 1  scfm    NI min    Nm   h   Pressure DewPoint at nominal condition       F     C  Nominal ambient temperature      F      Max  ambient temperature    F     1
3.                                     DMC20 Air Dryer Controller                  MAIN SWITCH  QUO cO    Oo     07 0      1777720          DIC eg 4  DMC20 Air Dryer Controller     Main switch     8  Air and refrigeration circuit flow diagram                                                      es    zb    Q                                                                   Q                                          5 2 OPERATION    The dryer described in this manual basically consists of two separated circuits  a compressed air circuit   divided into two heat exchangers  and a refrigeration circuit    The warm and humid entering air goes through an air to air heat exchanger before entering the evaporator   air to refrigerant heat exchanger  where  due to the contact with the refrigeration circuit  it cools down to  allow the condensation of the humidity it contains  The condensed humidity is partially expelled on the first  part of the evaporator and partially discharged after the    demister    condensate separator    The cooled air goes through the air to air heat exchanger  where it partially warms up in cooling down the  entering warm air  pre refrigeration     The refrigeration circuit needed for these operations is basically composed of a refrigeration compressor  a  condenser and an evaporator  also called air to refrigerant heat exchanger       260600000060       5 3 FLOW DIAGRAM  AirCooled                                                                                  
4.                              1    235   3GN3931             131000       Ad ZHO9 ASZS E   NVA XZ                      AlddNS    xog    A  zas    ZH09    097 6 6    dL    FIELD  INSTALLATION    INSTALLATION      ma    Voir sch    REMARQUE          5 24 2 SCHEMA ELECTRIQUE   AUXILIAIRE   TDF 420   TDF680   ADS93 CONTROLLER       z340  d         HH    a      s     x o     lt                 ie      q ve     els       Ox            m m       at   Ey d FE  d  Nr   O s i SLE 26  F   SE      AIR COOLED ONLY   AIR COOLED ONLY    BRIDGE FOR WATER COOLED   BRIDGE FOR WATER COOLED   TD       D z     x tr  0        45    S 5                   S  o  5      N    254 _  en 1     lt  2 en TVNOILdO            TTS     z  Q           D zl   x    9 5                       S     gt  A o                                     AINO 441009                       Ae NOT INSTALLED      OPTIONAL  ms 9 5N ol    ELECTRONIC DRAINER IS USED  Q z                   z o      NOT INSTALLED IF OPTIONAL  I    1no      9           ELECTRONIC DRAINER IS USED                   mu                         z 1NO             i               Ze  1 I  L LNO    5                                            i      8  Su 24  To SE io         y ar  zt zo        x      99975          an EE              SS  Lo K                          lt a             5 24 3 SCH  MA   LECTRIQUE   CONNEXIONS   TDF 420   TDF680   ADS93 CONTROLLER                white T1        red   T2           white   T2       2          3G18AWG    3G18AWG    3G1
5.                             341  15374110 HOSS3HdlNOO   HOLIMS SYNSS3Yd   Vd AAWA QION31OS SSVd A8 SVO LOH   gA3  Adis LAINI HOSS3HdINOO   HOLIMS                                      AlddNS H3MOd                                     AlddNS 91419313          AW1dSIO JINGOW OZONA                            3SVOXNVHO                           39018 HOOQ        HOLIMS          235  QN3931       OMVBLXL payloads sselun   ANO 937009       Hd ZHO9 ASZS E  u                             AlddNS       AL  x NOILOJLO  d    A         d TL S Y                      E                 4           ZH09 0S                    0     09      JL      OMVPLXL                                               D     2  09      9         097 5 5          TD285 SET 8 0    FIELD  INSTALLATION    FIELD  INSTALLATION    5 25 1 ELECTRIC DIAGRAM   POWER   TDF145 to TDF340     DMC20 AIR DRYER CONTROLLER                             see the electric diagram in the electric board     NOTE    5 25 2 ELECTRIC DIAGRAM   AUXILIARY 1   TDF145 to TDF340   DMC20 AIR DRYER CONTROLLER    TWNOILdO                  EISEN  I I  I                8  Tut                                   9     33JO NO          N                         441009            En    0               441009                CE        P              eil           geil         i   Ad        da   fel fv            ol 6    a Mee e ey Su               Eu            88888888     LL ozona        SE ANIOd M3Q  LL                                                       
6.                      FL    5 25 3 SCH  MA   LECTRIQUE   AUXILIAIRE 2   TDF145   TDF340   DMC20 AIR DRYER CONTROLLER           SI                                                 dl GATIVLSNI LON    peu  erm  I   1 I  Zeg  XE          1 ES     d 5                    f    fo   CL  A A               p    xa     S                                  NOLLO3NNO9             5 25 4 SCH  MA   LECTRIQUE   CONNEXIONS   TDF145   TDF340   DMC20 AIR DRYER CONTROLLER    BU 2  3G18AWG       12 2 Z   NW               gt              12 4 Se 3G18AWG          X   il  js pts                  il  RE                      21   ers        2   10   842 crane              BK  22   11 E     BN 1     gt     ere EZ               BN 1      2   _ BU 2  3618AWG    v                   ee        aet n                          Aa SUPPLYED BY CUSTOMER       31   2            e SUPPLYED BY CUSTOMER              49   23        BEES EE    522 1224     4G14AWG       UKK 5       white  m          red   T2 84   __   white   T2          red   T3     __  white 19                              1 44                         RS ES              white   T        red   T6    L           white   T6        red   T               white   T7      x                           white   T8                         BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALL
7.          LILILICICICILICICILIETETETEIETETEICIL TE                                                                                                          LILILILILILILILILILILILILILILILILILILILI LILILILILILILILILILILILILILILILILILILILI                   2 5 8in   65          Air Cooled   59 1 16in   1500    Water Cooled   53 3 4in   1365                         AirCooled  TDF145 TDF185    WaterCooled  TDF145 TDF185                    DRYER MODEL                                  Air flow rate at nominal condition   scfm  510 650 510 650   NI min  14500 18500 14500 18500   Nm3 h  870 1110 870 1110   Pressure DewPoint at nominal condition     F     C  38 3   Nominal ambient temperature    F     C  100   38   Max  ambient temperature  F     C         Min  ambient temperature 34 1  Nominal inlet air temperature  Max  inlet air temperature 113   45   Nominal inlet air pressure  psig   barg  100   7   Max  inlet air pressure  psig   barg  174   12   Max  outlet air pressure drop   Ap psig   barg  4 4   0 3   Inlet outlet air connection 2 1 2                Refrigerant type R404A   Refrigerant charging  oz   kg  125   3 5    Cooling air capacity           scfm m h   3240 50         Cooling water capacity at 60  F 15  C  gpm   m   h       1788 05   21   4 06      Cooling water capacity at 85  F 30  C         moll      578 16   658 18    Maximum water temperature  PF   C      86 90     Maximum water pressure  psig barg     1450    Max  water pressure drop  psig                  44 3 7
8.          OMVOLXL    9MVOLOF    TD420 520 SET 16  TD680 SET 20          9MVOLIX           2  09      097 6 6    dL    FIELD  INSTALLATION    FIELD  INSTALLATION    see the electric diagram in the electric board     NOTE    5 26 2 ELECTRIC DIAGRAM   AUXILIARY 1   TDF420 to TDF680   DMC20 AIR DRYER CONTROLLER    WNOILdO                  OINOHLO3T3     1     1        SES    S     0    6                                  411009                 411009          r 7771 qx  eu pcdes nd  pr    nf EURE           18    a  ML        2 2    viz            AU   ALL          vd tid                e  zm   9 v v        r 1  Eu        e    5       N      8  o  H  EE EE    1 1             BBBBBBBB    1 1  1 1  SS    EE 5        ee EE CODE      11               181 fo  um 5 fo  fo  191 on an             fi f fi fi    1 ib            031000         J    OZH NI 81   x     1NIOd M3Q  L1  IN3IgAV LL NI HIV ZL  SNISN3QNOO 9L LNO                   HOSS3HdWOO  SL    NI HOSS3HdWOO  EL    5 26 3 ELECTRIC DIAGRAM   AUXILIARY 2   TDF420 to TDF680   DMC20 AIR DRYER CONTROLLER    q3sSn SI              OINOH1O9313    TWNOILdO dl GATIVLSNI LON    FH    X             T7771    SETE     cl         428951       lt                   Be     lt     NOIL 3NNOO                 5 26 4 ELECTRIC DIAGRAM   CONNECTIONS   TDF420 to TDF680   DMC20 AIR DRYER CONTROLLER    BU 2  3G18AWG       12 2 Z   NW               gt              12 4 Se 3G18AWG          X   il  js pts                  il  RE                      21   ers    
9.       est automatique lorsque les conditions  nominales se r  tablissent    Pressions d   talonnage   Stop 14 5 psig  1 0 barg    Red  marrage 72 5 psig  5 0 barg    PA  Pressostat haute pression plac   sur le c  t   refoulant du compresseur  l intervient si la pression  augmente au del   de celle r  gl  e  Le r  armement est manuel et s effectue    l aide d une touche situ  e  sur le pressostat    Pressions d   talonnage   Stop 440 psig  30 5 barg    Red  marrage Manuel  PV  Interrupteur de s  curit   pour le ventilateur de contr  le de la pression de l unit   de condensation  situ      sur le c  t   sortie de l unit    Maintient la temp  rature et la pression de l eau condens  e    un niveau  constant et dans les limites d  finies  refroidissement    air      Pressions d   talonnage   Stop 260 psig   104   F  18 barg   40   C   Red  marrage 320 psig   122   F  22 barg   50   C     5 19 R  SISTANCE DU CARTER DU COMPRESSEUR    A de faibles temp  ratures  l huile se m  lange plus facilement avec le gaz cryog  ne   au d  marrage du  compresseur  on peut par cons  quent constater des   coups de liquide   et une train  e d huile dans le circuit  cryog  ne    Pour att  nuer ce probl  me  une r  sistance   lectrique a   t   install  e dans le carter du compresseur  celle ci  maintenant l huile    une temp  rature ad  quate lorsque le tableau est activ   et le compresseur    l arr  t  La  r  sistance est dot  e d un thermostat emp  chant toute surchauffe de l huile     REMARQUE  la 
10.      Vd  3491  LA INI HOSS3HdlNOO   HOLIMS 3HFSS3Hd         XO8 AlddNS 91419411                         3SVOMNVHO                        EI              031009                                            4         SNV9L9r X Z    2  09 06  VA0SL  AOZZIO9Y    JL      OMVPLXL       SMVPLXL           3 TD420 520 SET 4 0    JAVA QION31OS                    HOLVHVd3S             3ATVA QION31OS NIVHG                                         3ATVA dIONJTOS               SVO LOH            1H911 NO Wa   X            NO H3MOd               dOLS 14HVIS   d                                   sav   39018 4000        HOLIMS          235    3d ZH09 AS2G                            Addi    2       1   1   1       NOLLOALONd                                          E EE xog  0        j           SIW0L9r 08901                  025 0070                     I                 1 of rf  lt     295       9MVOLXL        e EE  N lu e 1         an           in gi       2109  e iQ 0 TRS  3 58 wakani   09  618      s z         ATE       9MVOIXL    FIELD  INSTALLATION    FIELD  INSTALLATION    see the electric diagram in the electric board     NOTE    5 24 2 ELECTRIC DIAGRAM   AUXILIARY   TDF420 to TDF680   ADS93 CONTROLLER         E  gom           wel  als    lt                   lt  mL MES Ky sg E  x       uoc RSS ge    OE  Q           ke             SES  Led         pre  AIR COOLED ONLY   AIR COOLED ONLY    BRIDGE FOR WATER COOLED   BRIDGE FOR WATER COOLED                 x D  0    095 5    T              
11.     2   10   842 crane               gt   3G18AWG       _        BU 2  3G18AWG  20 16 ERI               BU     YG      BN 1  PS                          L     20   21    SUPPLYED BY CUSTOMER         3   2                   SUPPLYED BY CUSTOMER        49   25     e     26              L    white                         vite T2       red      1 854        white   T3           red   T   1 844      vite         we  TT         TS         white   T5    TT red                   white                         red   T                 TZ                           white                                  BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    START STOP REMOTE CONTROL    REMOTE ALARM ON INDICATION    TF TRANSFORMER   460V SIDE          T1  DEW POINT    T2  AIR IN    T3  AIR OUT        T4  COMPRESSOR IN        T5  COMPRESSOR OUT    T6  CONDENSING    T7  AMBIENT    T8  WATER IN   WATER COOLED ONLY      gt  gt        Web            6 1 CONTROLS AND MAINTENANCE    The maintenance and the service operations for all drye
12.     20 338                           TTT     z        21 x g e      of     lei pep   Q  gt                     foto     2   m     A NO 31009       s    NOT INSTALLED IF OPTIONAL         5 ELECTRONIC DRAINER IS USED  z        NOT INSTALLED IF OPTIONAL  ELECTRONIC DRAINER IS USED       5                        m5 2        HH       CONDENSING  PROBE    KEE EN                 5 23 3 ELECTRIC DIAGRAM   CONNECTIONS   TDF145 to TDF340     ADS93 CONTROLLER    UKK5   15   1 8            PRE        3G18AWG x  3G18AWG X  3G18AWG x         Ce   3G18AWG                   3G18AWG    Hi             gt   3G18AWG Sch 0     _    3G18AWG    4G14AWG                 whie        e             T2            white  T2             BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    TF TRANSFORMER   460V SIDE          DEW POINT PROBE    CONDENSING PROBE    5 24 1 ELECTRIC DIAGRAM   POWER   TDF420 to TDF680   ADS93 CONTROLLER    TANVd IlOHINOO                 JHL 3GISNI NOILOSLOYd TVNAIHL   AL                          HOLIMS                    Ad          131100 HOSS3HdlNOO   HOLIMS               
13.     Code D Acc  s   Mot de passe pour acc  der au niveau 2 0   255           Langue S  lec  de la langue des messages de dialogue et d alarme    Italien   Anglais  Allemand   Fran  ais    v  PdC PointRose   nterventon Ev bypass    mn  Max PointRose  1 0  C      Dif PointRose Diferentei Ev bypass    92 00   02    A  Temps Purge E  Temps   vacuation Evaporateur    0   50        355      Pause Purge E  Pause entre deux cycles d   vacuation Evaporateur    0 5  10 min   10          Min PointRose   Valeur minimum de la plage de r  glage du PointRose     19 9 199  C  1 0            Condensation Point d intervention de l alarme pour une temp  rature de 50 0   70 0   C 60 0   C  condensation trop   lev  e   Diff    Condens  Diff  rentiel de   alarme pour une temp  rature de  1 0    10 0   K  5   K  condensation trop   lev  e    Ret   Condens                 de l alarme pour une condensation trop haute 0 5   20 min    Auto Activer la machine    l alimentation pour qu elle se remette  D  marra    l   tat dans lequel elle   tait lors de la coupure YES NO NO  ge 3t H  d alimentation     Reprise Appres     Auto reset  r  tablissement automatique  des alarmes YES NO  N  P  riph  rique                de l unit   dans le dialogue           01   255    5 21 4 COMMANDE A DISTANCE    Il est possible d allumer et d   teindre le s  cheur    distance    l aide d un simple interrupteur plac   m  me     longue distance et reli   par deux conducteurs seulement au DMC20  En fermant le contact de l inte
14.     Compressor  2     Demister    condensate separator  Condenser unit  3  Condensate accumulator   Liquid receiver Condensate drain service valve   Solid filter dryer  5  Condensate strainer   Liquid sight glass Condensate drain solenoid valve  Thermostatic expansion valve           7  Compressor                    heater  Evaporator   Air to refrigerant heat exchanger Condenser unit fan   Liquid separator Service valve   Hot gas by pass solenoid valve Electronic controller   ADS93 or DMC20  Refrigerant pressure switch Pa   Ps   Py     Temp  probes   T1  amp  T6 ADS93   T1 to T7 DMC20  Air to air heat exchanger  22 By pass system  optional     Air flow direction   Refrigerant flow direction      260600000060       5 4 FLOW DIAGRAM  WaterCooled      2     8r       ci                                                     Compressor  2     Demister    condensate separator  Condenser unit  3  Condensate accumulator   Liquid receiver Condensate drain service valve   Solid filter dryer  15  Condensate strainer   Liquid sight glass Condensate drain solenoid valve  Thermostatic expansion valve   TEX  7  Compressor                    heater  Evaporator   Air to refrigerant heat exchanger Condenser water regulating valve   Liquid separator Service valve   Hot gas by pass solenoid valve Electronic controller   ADS93 or DMC20  Refrigerant pressure switch Pa   Pg     Temp  probes   T1  amp  T6 ADS93   T1 to T8       20  Air to air heat exchanger  22 By pass system  optional     Air flow di
15.     NOLLO3LOHd     TVWSH3HLINI    SAW0 9r 08901  S9MVCLOY 0cS 0CVQ L    9MVOLOF         OMVOLXL    9MVOLOF    TD420 520 SET 16  TD680 SET 20        lt  TD420 520 SET 4 0              o TD680 SET 4 5       OMVOIXE          xog    2  09    097 6 6    dL    FIELD  INSTALLATION    FIELD  INSTALLATION      lectrique qui se trouve dams le tableau   lectrique       ma    Voir sch    REMARQUE    5 26 2 SCH  MA   LECTRIQUE   AUXILIAIRE 1   TDF420   TDF680   DMC20 AIR DRYER CONTROLLER    WNOLLdO  Lu           Q31000                 Q31000 uly   SANIYA       ug gege  eege  degen                          SEN EN 22   1    4        Kr  BEE ECH ERGA  Q 1 Ed 1 pi  1   1 EN  lt   1 N                   H                  Lele                    Al  CAL       Vd   ad   1 1   1   1     Lie              NE bow oo  2 Gi geb Ek e         f    ES nn  El 008       02  12 2          2  90 vL vL   m It 1   2 1         e 8 5 D    8 N  S      v  gege E EE                         1 I         REE BBBBBBBB     I I  I I                     in S       MEM  I I I       1 1 I I I I    I I 1  I I 1 1 1 1 1 I I I 1 1 1 I 1                                            fJ                   931009             J           NI 81 ANIOd M3Q  LL  AN3lgAV LL        SNISN3QNOO 91              1                          91                         FL    5 26 3 SCHEMA   LECTRIQUE   AUXILIAIRE 2   TDF420   TDF680   DMC20 AIR DRYER CONTROLLER           SI                                                 dl GATIVLSNI LON    peu  er
16.     c   ADS93 The alarm light is ON   see specific point    c   DMC20 The led    alarm    is ON   see specific point    c   Intervention of the electric protection  see Q3 and or Q4 on the  electric diagram  of the auxiliary circuit   restore it and check the  proper operation of the dryer    c   Verify the electric wiring     c   ADS93 The alarm light is ON   see specific point    c   DMC20 The led    alarm    is ON   see specific point    c   Activation of the compressor internal thermal protection   wait for 30  minutes  then retry    c   Verify the electric wiring    c   The compressor power contactor  see K on the electric diagram  is  faulty   replace it     gt  If the compressor still doesn t work  replace it     c   ADS93 The alarm light is ON   see specific point    c   DMC20 The led    alarm    is ON   see specific point    c   Verify the electric wiring    c   The fan s  power contactor  see V on the electric diagram  is faulty    replace it      gt       pressure switch is faulty   contact a refrigeration engineer to replace it     gt   f the fan s  still doesn t work  replace it       gt  The PB low pressure switch is activated   see specific point    c   The PA high pressure switch is activated   see specific point    c   The thermal protection  see TV on the electric diagram  inside the fan is  activated  wait 30 minutes and retry  AirCooled     c   The electric protection  see Q1 on the electric diagram  of the  compressor is activated   restore it and retry  
17.    4    49  49   40   49   49   49   49  Probe T7 5625NNN033 1  1  1    1   19  19   19 1   Probe T8  WaterCooled  5625NNN039  ALAN   1  AL 116   1    19  Extension for the probe 5625      029   24   2    2     2  126   2   126  29  89   8    8     8    8    8    8    86  Optional   5    485 230VAC 54905    005 only for serial communication   1 pcs for net  Optional   SBC485 115VAC 5490SBC010 only for serial communication   1 pcs for net       TDF   ADS93 Controller TDF   DMC20 Air Dryer Controller       SPARE PARTS              lighted switch  Lamp for ON OFF switch  Alarm red light  Lamp for alarm red light  Condensate drain strainer  Drain solenoid valve   body  Drain solen  valve coil 230VAC    CODE  5452PLS020  5480NEN010  54521ND005  5480      005  64355FF011  64320FF011  64  22    021                                     pepe Mee                              EZ                                                     SE      E                   KAREL             ER ie      ip         1     2  2  2e  2e    2 22                L                                                                               Drain solen  valve   coil 24 VAC   64N22MM016 2    2    2    2    2    20   26  2   Optional Elect  drain 230        2210                 1 1 1 1 1 1 1 1   Optional Elect  drain 24VAC 2210BEKO05L 1 1 1 1 1 1 1 1  By pass solenoid valve     body   64120SS015   1 1 1 1 1 1 1 1 1 1 1 1   By pass solenoid valve     body   64120SS020 1 1 1 1  By pass solen  valve coil 230VAC   64 
18.    59 1 16in   1500    Water Cooled   53 3 4in   1365          AirCooled   WaterCooled    DRYER MODEL TDF210   TDF285   TDF340   TDF210   TDF285   TDF340  Air flow rate at nominal condition 1  scfm     NI min     Nm3 h   Pressure DewPoint at nominal condition     F     C  38 3  Nominal ambient temperature    F    C 100   38    Max  ambient temperature    F     C  113   45    Min  ambient temperature    F     C  34 1    100   38   Max  inlet air temperature    F     C  113   45   100   7   174   12   44   0 3   Flange 3   150   R404A   180 50 245 70    Cooling air capacity  scfm   msn    2240 2830   4800    Cooling water capacity at 60     15      gpm mail    278 08 358 10  4 11  Cooling water capacity at 85  F 30  C          m h l       834 24  11 30   1218 33  Maximum water temperature    F    C        C 86   30             145   10  i  575 3 60    Max  electric consumption  A      Compressor power  HP        Max  noise level  gt  70 dbA at 40 in  1m        1 The nominal condition refers to an ambient temperature of 100   F  38   C  with inlet air at 100 psig  7 barg   and 100   F  38   C      4 3 TECHNICAL FEATURES OF DRYERS SERIES TDF420  TDF520 and TDF680    27 9 16in   700 78 3 4in   2000    LILILILILILILILILILILILILI  LILILILILILILILILILILILILI                                                 D  el                                                                         DI  D  I  D  I  D  I  D  I  D  I  D  I  D  I  D  I  CO  CO  D  I                                       
19.    Cooling water connections          Max  electric consumption IW 62   68   51  58      1 The nominal condition refers to an ambient temperature of 100   F  38   C  with inlet air at 100 psig  7 barg   and 100   F  38   C         4 2 TECHNICAL FEATURES OF DRYERS SERIES TDF210  TDF285 and TDF340    23 5 8in   600 72 5 8in   1850                                                                                                                                                                                                                                                                                                                   LILILILILILILILILILILILILILILILILILILILI  LILILILILILILILILILILILILILILILILILI LILILILILILILILILILILILILILILILILILILILI                                                                                                                                                                                                               EIDIEICICIEIEIEIEIEEICIEIEIETEIEIETETEI  LILILICICICILILICILIEIE TE IE IETEIEICIL TE                                                                                                                                                                                                                                                                                                                                                                                                           D  e  el  D  D                                  Air Cooled
20.    Delay Delay time for the too high condensation temp  alarm 0 5   20 min    Start at Machine enabled to restore its operation after a power YES NO NO  Power Up black out    Recovery After     Automatic alarms reset YES NO  Peripheral No    Unit address for serial communication 01   255    5 21 4 REMOTE COMMAND    It is possible to remotely switch the dryer ON and OFF by means of a simple switch connected with two  wires to the DMC20  see terminal 16 and 17 on the electric diagram   Closing the contact of the command  switch  on the display appears the message  Stand by Remote   and no functions will be selectable on the  local panel  as soon as the contact is opened  the dryer returns to the previous condition  Stand by if it was  in Stand by condition  ON if it was ON      i IF INSTALLED  THE REMOTE CONTROL HAS PRIORITY ON THE FRONTAL COMMANDS OF THE DMC20  THE          N               USER WILL BE RESPONSIBLE FOR THE INSTALLATION OF PROPER PROTECTIONS FOR POSSIBLE SUDDEN  POWER RESTORATION TO THE DRYER     5 21 5 REMOTE ALARM SIGNAL    A voltage free contact is provided for remote annunciation of any alarm condition of the dryer  see terminal  18  19 and 20 on the electric diagram      5 21 6 ACCESS CODE  A serviceman s code is required to access level 2     The manufacturer accepts no responsibility for damages due to the alteration of the operating  parameters     Me The password is specified in the last page of this manual   The password must be kept by qualified perso
21.    Ne jamais travailler sur le s  cheur s il a des pi  ces sous pression    Ne pas diriger le jet d air comprim   ou d   vacuation de la condensation vers des personnes    L utilisateur doit veiller    faire installer le s  cheur conform  ment aux instructions donn  es dans le   chapitre  Installation   Dans le cas contraire  la garantie devient nulle  certaines situations    risque   peuvent se cr  er pour les op  rateurs et ou entrainer une d  t  rioration de la machine    Seul un personnel qualifi   est habilit      utiliser et    effectuer les op  rations d entretien d appareils      alimentation   lectrique  Avant de commencer    effectuer toute op  ration d entretien  il est   n  cessaire d observer les instructions suivantes     e S assurer que la machine n ait pas de pi  ces sous pression et qu elle ne puisse pas   tre  rebranch  e au r  seau d alimentation   lectrique    e S assurer que le s  cheur n ait pas de pi  ces sous pression et qu il ne puisse pas   tre rebranch       l installation de l air comprim      Ces s  cheurs    circuit frigorifique contiennent fluide r  frig  rant type R404A  n est pas consid  r     potentiellement nuisible pour l ozone  La maintenance du circuit frigorifique doit   tre effectu  e   exclusivement par du personnel qualifi    en accord avec les normes du pays en vigueur  Le   r  frig  rant R404A peut   tre dangereux pour l homme seulement si pr  sent en concentrations     lev  es  En cas de pertes  le local doit   tre a  r   avant cha
22.    teindre le s  cheur  en  s  lectionnant YES  ou pour donner seulement une indication d alarme    e   PointRose Haut   sert    d  finir le seuil d intervention de l alarme pour un PointRose Haut    e Diff   PR Haut   c est la temp  rature diff  rentielle pour d  sactiver l alarme pour un PointRose Haut    e Retard   PR Haut   sert    d  finir le retard en minutes de l alarme pour un PointRose Haut  en d  finissant  par exemple un      PointRose Haut    sur 15  un    Diff   PR Haut    sur  5 et un  Retard   PR Haut    sur 10   l alarme se d  clenche lorsque le PointRose reste au dessus de  15  C pendant 10 minutes au moins et se  d  sactive d  s que le PointRose descend au dessous de  10  C    e Stop   PR Haut   il est possible d activer l alarme pour un PointRose Haut pour   teindre le s  cheur  en  s  lectionnant YES  ou pour donner seulement une indication d alarme          Condensation   on d  finit le seuil d intervention de l alarme pour une temp  rature de condensation trop   lev  e     e Diff    Condens    c est la temp  rature diff  rentielle pour d  sactiver l alarme pour une temp  rature de  condensation trop   lev  e    e Ret    Condens    sert    d  finir le retard en minutes de l alarme pour une temp  rature de condensation  trop   lev  e  en d  finissant par exemple un    Condensation  sur 60  un  Diff    Condens     sur  5 et un  Ret     Condens     sur 10  l alarme se d  clenche lorsque la temp  rature de condensation reste au dessus de   60  C pendant 10 mi
23.   29 personnel   Before any intervention  Ensure that      e no part of the machine is powered and that it cannot be connected to the mains supply   e no part of the machine is under pressure and that it cannot be connected to the  compressed air system             SYMPTOM POSSIBLE CAUSE   SUGGESTED ACTION      No led lighting up  c   Check for mains failure   c   Verify the electric wiring  internal and or external    c   Check internal printed circuit board for possible damage         Pressing of Test button  but no  gt  The service valve located before the drain is closed   open it   condensate discharge    gt  The dryer is not under pressure   restore nominal condition   c   Solenoid valve defective   replace the drain   c   The internal printed circuit board is damaged   replace the drain        Condensate discharge only  gt  The capacitive sensor is too dirty   open the drain and clean the  when Test button is pressed  sensor plastic tube         Drain keeps blowing off air  c   The diaphragm valve is dirty   open the drain and clean it     The capacitive sensor is too dirty   open the drain and clean the  sensor plastic tube         Drain in alarm condition    The capacitive sensor is too dirty   open the drain and clean the  sensor plastic tube     gt  The service valve located before the drain is closed   open it     gt  The dryer is not under pressure   restore nominal condition   c   Solenoid valve defective   replace the drain     NOTE   When the drain is in alarm
24.   ADS93  L instrument ADS93 est d  fectueux   le remplacer     gt  DMC20  L instrument DMC20 est r  gl   sur un set point trop Bas   voir  paragraphe    Set Up Programmation  du DMC20     gt        20  L instrument DMC20 est d  fectueux   le remplacer      gt  L   lectrovanne by pass gaz chaud est bourr  e   contacter un technicien  frigoriste       gt  Le PointRose est trop Bas   le condensat s est congel   et l air ne peut  pas passer   voir paragraphe sur ce sujet    c   V  rifier sir les tuyaux flexibles de raccordement sont   trangl  s  si elles  sont utilis  es       Le s  parateur de le condensat est bouch     le nettoyer ou le remplacer     c   La les   lectrovanne s  d   vacuation est sont bourr  e s    d  monter et  nettoyer     gt  V  rifier les c  bles   lectriques      gt  ADS93  L instrument ADS93 est d  fectueux   le remplacer      gt  DMC20  L instrument DMC20 est d  fectueux   le remplacer      gt  V  rifier les c  bles   lectriques     gt  Le filtre m  canique d   vacuation du le condensat est bouch     le  d  monter et le nettoyer      gt  Le vanne de service pour l   vacuation du le condensat est clos   le ouvrir     gt  L   lectrovanne d   vacuation est bourr  e   la d  monter et la nettoyer      gt  La bobina de l   lectrovanne d   vacuation du le condensat est br  l  e   la  remplacer     gt  ADS93  L instrument ADS93 est d  fectueux   le remplacer      gt  DMC20  Les temps d   vacuation ont   t   r  gl  s sur z  ro   voir  paragraphe    Set Up Programm
25.   Ole     g  e       gt    lt  E      ko     2o 5            al          U  216      el E          e  D  5                 3      9 3        D  o             EES  o      5      D          3         ko ko  2 2                5 5              Ke                                                          NINININININININ                                                 ND  az zz za      2  22222                      ow DewPoint alarm ON  igh DewPoint alarm ON    Sg          Condens            High Condensation temperature alarm ON bit   1 Yes  STOP Compr LP bit   1 Ves  STOP Compr  HP bit   1 Yes  Ean Protection bit   1 Ves  Protection Comp  bit   1 Yes  Probe Fault bit   1 Ves  Low       Stop bit   1 Yes  High DP   Stop bit   1 Ves  Start at Power Up bit   1 Yes  Recovery After  bit   1 Yes  ON OFF DMC20    Status of DMC20   ON or OFF  Stand by  bit   1 Stand by            1  Language selection   00 Italian   01 English   02 German   03 French  R Read   W Write    Register  Address    0000  R  0001  R  0002   R  0003   R  0004   R  0005   R  0006   R  0007   R    0200   R W    0    0  0  0    0  0    0  0  0  0  0    201   RW    210   RW  211   RW  212   RW    213   RW  214   RW    215   RW  216   RW  217   RW  218   RW  219   RW    0246   RW  0100 0   R  0100 1   R  0101 3     0101 6   R    0102 0   R  0102 1   R  0102 2   R  0102 4   R  0102 5   R  0102 6   R  0102 7   R  0102 8   R  0220 0     0220 1     0220 2      0220 3      5    0220 15     5 22 ELECTRONIC LEVEL DRAIN   OPTI
26.   Temp  rature air   F   590 1           Comment d  terminer le d  bit d air r  el   Comment d  terminer le bon mod  le de s  cheur  une fois les conditions de service connues            D  bit D  bit Facteur Facteur  Facteur  Facteur  D  bit D  bit Facteur   Facteur   Facteur  Facteur    d air     nominal   X x th  orique Z  d air       lt a    r  el de principe    F1   F2   F3   F4  de cioe demand    F1   F2   F3   F4                                                                                Exemple   Exemple      Un s  cheur TDF 340 a un d  bit nominal de Sachant que les param  tres de fonctionnement  principe de 1200 scfm  2040 Nm  h   Quel est le     sont les suivants      d  bit maximum pouvant   tre obtenu dans les vus ur RN 3  conditions de fonctionnement suivantes    Debit dar demande 1909 sem FOO pm      Pression air en entr  e   115 psig  7 9 barg       Temp  rature ambiante   110   F  43 3   C         Temp  rature air en entr  e   110   F  43 3   C         Pression air en entr  e   115 psig  7 9 barg       Temp  rature ambiante   110   F  43 3   C         Temp  rature air en entr  e   110   F  43 3   C         DewPoint sous pression   38   F  3 3   C    DewPoint sous pression   38   F  3 3   C     Pour d  terminer le bon mod  le de s  cheur  diviser le  d  bit d air demand   par les facteurs de correction  relatifs aux param  tres ci dessus      A chaque param  tre de fonctionnement  correspond un facteur num  rique qui  multipli   par  le d  bit nominal de pr
27.   c   The electric protection  see Q2 on the electric diagram  of the fan s  is  activated   restore it and retry  AirCooled      c   One of the following appears on the upper line of the DMC20 display       Protection Comp     Intervention of the electric protection  see Q1 on  the electric diagram  of the compressor   restore it and check the  proper operation of the dryer    2   Protection Fan     AirCooled  Intervention of the electric protection  see  Q2 on the electric diagram  of the fan   restore it and check the proper  operation of the dryer or Intervention of the thermal protection  see TV on  the electric diagram  inside the fan   wait 30 minutes and retry    3   STOP Compr  LP    The PB low pressure switch is activated   see  specific point    4   STOP Compr  HP    The PA high pressure switch is activated   see  specific point    5   Condens  HIGH    condensing temperature is too high   see specific point    6   DewPoint LOW    DewPoint is too low   see specific point    7  DewPoint HIGH    DewPoint is too high   see specific point    8   Probe Fault    one of the probes is faulty   see specific point              The low pressure switch PB has  gt  There is a leak in the refrigeration circuit   contact    refrigeration    been activated     engineer     gt  The pressure switch resets automatically when normal conditions are  restored   check the proper operation of the dryer         The high pressure switch        gt  Check which of the following has caused the 
28.   e V  rifier que tous les points du chapitre     Installation    sont respect  s       V  rifier que les raccordements air comprim      la  machine sont bien serr  s et que les conduites sont  bien fix  es    e V  rifier que les dispositifs d   vacuation du sont  bien fix  s et raccord  s    un r  cipient ou    une  installation de collecte    e V  rifier que le syst  me by pass  si install    est ferm        V  rifier que les clapets manuels situ  s sur les  circuits d   vacuation du le condensat sont ouverts    e Eliminer tous les emballages et tout ce qui peut  entraver dans la zone du s  cheur    e Activer l interrupteur g  n  ral d alimentation    e Activer le sectionneur g  n  ral   rep  4 du pupitre  de commande    e V  rifier que le t  moin de pr  sence de la tension  du bouton lumineux               rep  re 1 du  pupitre de commande   est allum      e Attendre au moins deux heures avant de faire  d  marrer le s  cheur  la r  sistance carter doit  chauffer l huile du compresseur        V  rifier que le d  bit d eau de refroidissement est  pr  sent  refroidissement    eau     e Appuyer sur la touche    I   ON  du bouton lumineux  ON OFF   rep  re 1 du pupitre de commande       V  rifier que l   cran de l instrument ADS93 s allume    e Attendre quelques minutes  v  rifier que  l instrument     ADS93 indique la bonne  temp  rature de service et que le condensat est  r  guli  rement   vacu      e V  rifier que l absorption   lectrique est conforme  aux donn  es figurant 
29.   remplacer le compresseur       gt  ADS93  Le t  moin de pr  sence d alarme est allum     voir paragraphe sur ce sujet      gt  DMC20  Le t  moin  alarme en cours    est allum     voir paragraphe sur ce sujet     gt  V  rifier les c  bles   lectriques    c   Le t  l  rupteur de commande du ventilateur  voir V sur sch  ma    lectrique  est d  fectueuse   le remplacer    c   Le pressostat Pv est d  fectueux   contacter un frigoriste      Si le d  faut persiste  remplacer le ventilateur       gt  Le pressostat de basse pression PB s est d  clench  e   voir paragraphe sur ce sujet      Le pressostat de haute pression PA s est d  clench  e   voir paragraphe sur ce sujet    c   La protection thermique  voir TV sur le sch  ma   lectrique  s est d  clench  e   Attendre 30 minutes et faire une nouvelle tentative  refroidissement    air     c   La protection   lectrique  voir Q1 sur le sch  ma   lectrique  du compresseur  s est d  clench  e   la r  amorcer et v  rifier le bon fonctionnement du s  cheur      La protection   lectrique  voir Q2 sur le sch  ma   lectrique  du  ventilateur s est d  clench  e   la r  amorcer et v  rifier le bon  fonctionnement du s  cheur  refroidissement    air      c   Sur la premi  re ligne de l   cran du DMC20 s affiche l un des messages suivants     1     Protection Comp     le dispositif de protection   lectrique  voir Q1 sur sch  ma    lectrique  du compresseur s est d  clench     le r  armer et v  rifier le bon  fonctionnement du s  cheur    2     P
30.   xz  6  o  55  5    m      E TVNOILdO  2 QE    ul    Al                        931009                    NOT INSTALLED IF OPTIONAL  0 5 9c    ELECTRONIC DRAINER IS USED     z               Pd  al  ei             NOT INSTALLED IF OPTIONAL     1no ET     9       ELECTRONIC DRAINER IS USED              as  ne  S    35             HH       KEE EN    CONDENSING  PROBE         bet kt bet         HA    Ser         5 24 3 ELECTRIC DIAGRAM   CONNECTIONS   TDF420 to TDF680   ADS93 CONTROLLER                white T1        red   T2           white   T2       2          3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    4G14AWG     mu           EE X    Evos  X       BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH  FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    TF TRANSFORMER   460V SIDE    DEW POINT PROBE    CONDENSING PROBE                  AGISNI NOLLO31OHd TVIWd3H1   AL 3ATVA QION31OS                                    5                                     HOLIMS SYNSS3ed   Ad 3ATVA             8 NIVHG                  
31.  1 1  Q3   Circuit breaker 54443STO20   1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1                                                    QA   Circuit breaker 54441C6005   1 1 1 1 1 1 1 1   Q4   Circuit breaker 54442C6015 1 1 1 1 1 1 1 1  Q1  amp  Q2   Auxiliary contact 5490CAX050   2   2 212 212 21212 2   2 2   2 2  2 2  K   Power contactor 5454TLT116 1 1 1 1 1   K   Power contactor 5454TLT016 1 1 1 1 1   K   Power contactor 5454TLT125 1 1 1   K   Power contactor 5454TLT025 1 1 1  V   Power contactor 5454TLT111 1 1 1 1 1 1 1 1   V   Power contactor 5454TLT011 1 1 1 1 1 1 1 1  K   Auxiliary contact NO 5490CAX011 1 1 1   K   Auxiliary contact NC 5490CAX010 1 1 1 1 1 1  A   Auxiliary relay 5456REL110   1 1 1 1 1 1 1 1   TF     Transformer 5440TFM020   1 1 1 1 1 1 1 1   TF     Transformer 5440TFM021 1 1 1 1 1 1 1 1       Numbers refers to installed quantity         Suggested spare part     FOR SPARE PARTS ORDERING SPECIFY DRYER LABEL DATA    7 1 TROUBLE SHOOTING    The refrigerating fluid  if under pressure  can cause serious injury to skin and eyes     The troubleshooting and resultant service work should be carried out by qualified personnel   Me Particular attention must be paid in case of service work on the refrigerating circuit     SYMPTOM      The dryer doesn t start         The compressor doesn t work         The  fan s  doesn t work    AirCooled        ADS93 The alarm light is ON       DMC20 The led    alarm    is ON     POSSIBLE CAUSE   SUGGESTED ACTION    c   Check for mains failure
32.  22    060   1    14   14   14   19   1    19   19   By pass solen  valve coil 240VAC   64N22MM045 19   1    1    1    1   19 110   19  Refrigeration compressor 5015340004 1 1   Refrigeration compressor 5015340006 1 1   Refrigeration compressor 5015340011 1 1   Refrigeration compressor 5015340008 1 1   Refrigeration compressor 5015340012 1 1   Refrigeration compressor 5015340018 1 1  Refrigeration compressor 5015340023 1 1  Refrigeration compressor 5015340026 1 1  Thermostatic valve     TEX 64130SS220   1 1 1 1   Thermostatic valve     TEX 6413055222 1 1   Thermostatic valve            6413055226 1 1 1 1   Thermostatic valve            6413055250 1 1  Thermostatic valve            6413055255 1 1  Thermostatic valve            6413055260 1 1       5655NNN090   1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1  5655NNN095   1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1    Pressure switch PV  AirCooled   Pressure switch PB     PA                                           Demister pad cond  separator  585670145005   1 1   Demister pad cond  separator  5856TD185005 1 1 1 1   Demister pad cond  separator  5856TD285005 1 1 1 1   Demister pad cond  separator  5856TD420005 1 1 1 1  Demister pad cond  separator  5856TD680005 1 1  SEZ   Main switch 5450SZN100   1 1 1 1 1 1 1 1 1 1   SEZ   Main switch 5450SZN105 1 1 1 1 1 1  Q1   Circuit breaker 54443SM050   1 1 1 1 1 1 1 1 1 1   Q1   Circuit breaker 54443SM060 1 1 1 1 1 1  Q2   Circuit breaker 54443SM030   1 1 1 1 1 1 1 1 1 1   Q2   Circuit breaker 544435  045 1 1 1 1
33.  6 Condenser  AirCooled    5 7 Condenser  WaterCooled    5 8 Condenser water regulating valve  WaterCooled    5 9 Liquid Receiver   5 10 Dehydration Filter   5 11 Liquid Sight Glass   5 12 Thermostatic Expansion Valve     TEX   5 13 Evaporator   5 14 Liquid Separator   5 15 Hot Gas By pass Solenoid Valve   5 16  Air to Air Heat Exchanger   5 17    Demister    Condensate Separator   5 18 Refrigerant Pressure Switch Pa   Pg   Py   5 19 Compressor Crankcase Heater   5 20 ADS93 Controller   5 21 DMC20 Air Dryer Controller   5 22 Electronic Level Drain   Optional   5 23 Electric Diagram TDF 145 to TDF340     ADS93 Controller  5 24 Electric Diagram TDF420 to TDF680     ADS93 Controller  5 25 Electric Diagram TDF 145 to TDF340     DMC20 Air Dryer Controller  5 26 Electric Diagram TDF420 to TDF680   DMC20 Air Dryer Controller  MAINTENANCE AND SPARES   6 1 Controls and Maintenance   6 2 Suggested Spare Parts   TROUBLESHOOTING AND DISMANTLING   7 1 Troubleshooting   7 2 Dismantling of the Dryer  EXPLODED VIEWS   8 1 Table of Components   Dryers TDF145 to TDF680   8 2 Dryers TDF 145 to TDF340   AirCooled   8 3 Dryers TDF420 to TDF680   AirCooled   8 4 Dryers TDF 145 to TDF340   WaterCooled   8 5 Dryers TDF420 to TDF680   WaterCooled    1 1 DEFINITION OF THE SIGNS USED IN THIS MANUAL    Before attempting any intervention on the dryer  read carefully the instructions reported in this use  and maintenance manual     General warning sign  Risk of danger or possibility of damage to the machi
34.  C                                          e Allow at least a clearance of 40 in  1 m  on each  side of the dryer for proper ventilation and to nr        facilitate eventual maintenance operations          1m          The dryer does not need to be fixed to the  supporting surface        2 3 INSTALLATION LAYOUT       Air compressor       Aftercooler                                                                Condensate separator  Pre Filter  Compressed air tank                Final filter  Dryer  By pass group                       9    65         Condensate drain                                                                               Type A installation is suggested when the compressor operates at reduced intermittence and the total  consumption equals the compressor flow rate     Type B installation is suggested when the air consumption can consistently change with peak values highly  exceeding the flow rate of the compressors  The capacity of the tank must be sized in order to compensate  eventual instantaneous demanding conditions  peak air consumption      2 4 CORRECTION FACTORS    Correction factor for operating pressure changes    Inlet air pressure _ psig  7 9      60   70   8             41   48   59   69   79   90   97   107   120      Correction factor for ambient temperature changes  AirCooled     Ambient temperature      80   590   100   110    C                                                                                        Factor  F2      109   
35.  HH    o         e         eo  lt      of 2        lt                   ve BCE                                  EIE     Se E Oui    r            amp     a Si  gs Su    ue    gt      2 ZE         LSA         NOIRS       AIR COOLED ONLY    BRIDGE FOR WATER COOLED   TD  N      gt      x tr  0    C935  aT 5        amp    gt         o  5        N    254 _  en 1     lt  2 en TVNOILdO                              x 2 ps y  la uyth        gt  1778   77 E se             AINO 931009       e      EA NOT INSTALLED IF OPTIONAL         3           OS 92    ELECTRONIC DRAINER IS USED     2   lt o          gt  S JL e NOT INSTALLED IF OPTIONAL        ino      92    ELECTRONIC DRAINER IS USED         S 2      DS                    elle          eal   1       L SES 92  i    PL wonn Ze                  az                                        l      2  Gui 28  eo         Go  zx ame  us st          2 99975          pum M    44      ol                2 9           5 23 3 SCH  MA   LECTRIQUE   CONNEXIONS   TDF145   TDF340   ADS93 CONTROLLER    UKK5   15   1 8             PED       3G18AWG x  3G18AWG     3G18AWG x         Ce   3G18AWG                   3G18AWG    Hi             gt   3G18AWG Sch 0     _    3G18AWG    4G14AWG                 whie        e             T2            white  T2             BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR C
36.  IL   IL   IL   IL                               LICILILICILILILILII  LICILILILILILILILILII  LICILILILILILILILILII  LICILILILILILILILILII  LICILILILILILILILILII  LICILILILILILILILILII  LICILILILILILILILILII                            0000929000210  0909092000212  0000929000212  0900929000212  0000299000212  9900929000221  0000929000210  0909092200021  0000929900022  9900921900021  0000929000212  9009022000212  0000920002120  0000690002121  0000000021210  0000000001210  0000999000212  0000600021210  0000000021210  0000090002120                                                                       Air Cooled   68 7 8in   1750    Water Cooled   63 5 8in   1615          Refroidissement    air Refroidissement    eau  MODELE du S  CHEUR TDF420   TDF520   TDF680   TDF420   TDF520   TDF680  D  bit nom  d air 1  scfm     NI min    Nm   h    130   55  Temp  rature ambiante minimum    F     C     D  bit de l air de refroidissement  ofm m   700 1200 IS  D  bit de l eau de refroid     60     15             mill    518 14   749   834 24      D  bit de eau de siet    85  F 30 C                       2078 57   2534 73     Temp  rature maximum      l eau      F  C     86 0     Pression maximum del eau      psip barg                     1450       Chute depression de l eau  Ap   psi ba   el 44 03     Raccordements entr  s   sortie de l eau   1 1 2  NPT F    Consommation nom  d  cris WI 119   143   179   98   122   149     Puissance   lectrique compresseur        6   85   10   6   85   10      
37.  Marche                   si l alarme     cess    le s  cheur reprendra normalement sa marche   sinon  le message d alarme sera de nouveau  propos    Avec  Auto D  marrage  et  Reprise Apres    d  sactiv  s   mis sur  YES    toute alarme ayant  provoqu   l arr  t du s  cheur et toute anomalie sur l une des sondes  Sonde en Panne  automatiquement  annul  e lorsque les conditions nominales se r  tablissent et le s  cheur reprendra sa marche normale  Toute  alarme ne provoquant pas l arr  t du s  cheur est automatiquement annul  e lorsque les conditions  nominales de fonctionnement se r  tablissent     5 21 3 SET UP  PROGRAMMATION     Le DMC20 est r  gl   lors de l essai du s  cheur  Pour des exigences particuli  res de fonctionnement ou de  gestion des alarmes  le client a la possibilit   de modifier les param  tres gr  ce    la fonction de  programmation  Les param  tres de programmation sont r  partis sur deux niveaux  quiconque peut  acc  der au niveau 1 alors que seul le personnel autoris   connaissant le mot de passe peut acc  der au  niveau 2  Pour acc  der    la fonction de programmation  il faut appuyer pendant 2 secondes minimum sur la  touche  11     Acc  s    la programmation   A l aide des touches  12  et  13   afficher le param  tre voulu et le  modifier    l aide des touches  12  et  13  en appuyant sur la touche  11   Pendant la programmation  le  param  tre s  lectionn   apparait sur la ligne sup  rieure de l   cran tandis que s affiche la valeur actuelle du  pa
38.  PL    5 25 3 ELECTRIC DIAGRAM   AUXILIARY 2   TDF145 to TDF340   DMC20 AIR DRYER CONTROLLER    q3Sn SI              DINON LO3 T3  TWNOILdO dl GATIVLSNI LON    rt IT   I 1   I           XE     I   ir Eg   1   I 1   1   I      I   l I   1 1        MEM 1   9          Is                  NOIL 3NNOO  viva       5 25 4 ELECTRIC DIAGRAM   CONNECTIONS   TDF145 to TDF340   DMC20 AIR DRYER CONTROLLER    BU 2  3G18AWG       12 2 Z   NW               gt              12 4 Se 3G18AWG          X   il  js pts                  il  RE                      21   ers        2   10   842 crane              BK  22   11 E     BN 1     gt     ere EZ               BN 1      2   _ BU 2  3618AWG    v                   ee        aet n                          Aa SUPPLYED BY CUSTOMER       31   2            e SUPPLYED BY CUSTOMER              49   23        BEES EE    522 1224     4G14AWG       UKK 5       white  m          red   T2 84   __   white   T2          red   T3     __  white 19                              1 44                         RS ES              white   T        red   T6    L           white   T6        red   T               white   T7      x                           white   T8                         BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRE
39.  condition  the diaphragm solenoid valve will open 7 5 sec every 4 min     5 23 1 ELECTRIC DIAGRAM   POWER   TDF145 to TDF340   ADS93 CONTROLLER    T3NVd TOULNOO            dH1 3GISNI NOILOSLOYd                                            HOLIMS                               131100 HOSS3HdlNOO   HOLIMS 34NSS4d    3GIS L3 NI HOSS3HdINOO   HOLIMS 3HFSS3Hd       XO                  3S VOMNVHO                                  AlddNS 91419413    59                      S             CN    2  09 06            AOZZIO9Y    JL      OMVPLXL                            d9    Ad  Vd           KINO 431009                     JAVA QION31OS                   HOLVHVd3S             3ATVA QION31OS                                                  3ATVA QION31OS               SVO LOH           1H911 NO            X           NO H3MOd               dOLS LAVIS   d                                  Sav  39018 4000        HOLIMS          235  GN3931  3d ZH09 ASZS                          AlddNS       I  1     E       NOIL9310Ud  de                      m  I                                           9MVvLOF    TD285 SET 8 0                             2  09    097 6 6    dL    FIELD  INSTALLATION    INSTALLATION    see the electric diagram in the electric board     NOTE    5 23 2 ELECTRIC DIAGRAM   AUXILIARY   TDF145 to TDF340   ADS93 CONTROLLER         E         of 1             lt         cols        COOLED ONLY    BRIDGE FOR WATER COOLED   TD          QE    06  a                 xz         6   Be    
40.  contacter en cas de probl  me ou pour tout  compl  ment d information     PLAQUE D IDENTIFICATION    Les caract  ristiques principales  de la machine figurent sur la  plaque d identification  qui se                                                    aed   de              Mod  le   gt  us    installation        bon    cr                     j   D  bit Nominale d Air      en reportant celles figurant sur un Nominal Flow Rate               la plaque d identification  Les Pression Maximum d Air  lt     Max Air Pressure      caract  ristiques  retranscrites Temp  rature Maximum d Air     Max Inlet Air Temp   devront toujours   tre Temp  rature Ambiante c   Ambient Temp                              4  R  frig  rant  Type Quantit      Refrigerant                   ou au reven      pour Pression de Project Refrig  HP LP    Refrig  Design Pres  HP LP barg  EE Mes  nman Alimentation   lectrique   Electric Suppl h VIH  des pi  ces de rechange  etc  4  Pie    1                     Mie  m  me pendant la p  riode de ulssance electrique nominale Electric Nominal Power W A  garantie  Fusible Maximum   Fuse Max         L     limination ou la d  t  rioration Produit   Manufactured CE  de la plaque d identification  annule tout droit    la garantie  TARTE LUI   CONDITION DE GARANTIE    La garantie couvre  pendant 14 mois    partir de la date de mise en service et une dur  e ne d  passant pas  14 mois    compter de la date d exp  dition  les   ventuelles pi  ces d  fectueuses    l origine qui s
41.  finit le temps d   vacuation du condens  t de l   lectrovanne situ  e dans l   vaporateur    e Pause Purge E  d  finit la pause entre deux cycles d   vacuation de l   lectrovanne situ  e dans l   vaporateur    e Temps Purge S  d  finit le temps d   vacuation du condens  t de l   lectrovanne situ  e dans le s  parateur de condens  t    e Pause Purge S  d  finit la pause entre deux cycles d   vacuation de l   lectrovanne situ  e dans le s  parateur de condensat    e Contraste Affic    r  gle au mieux le contraste de l   cran en fonction de l angle visuel  de la lumi  re  ambiante  de la temp  rature ambiante  etc     NIVEAU 2    e Min PointRose   c est la valeur minimum de la plage de r  glage du  PdC PointRose  du niveau 1    e Max PointRose c est la valeur maximum de la plage de r  glage du    PdC PointRose  du niveau 1         PointRose Bas  sert    d  finir le seuil d intervention de l alarme d un PointRose bas    e Diff   PR Bas   c est la temp  rature diff  rentielle pour d  sactiver l alarme d un PointRose bas    e Retard   DP Bas   sert    d  finir le retard en minutes de l alarme d un      PointRose Bas   en d  finissant  par exemple un      PointRose Bas    sur  5  un  Diff   DP Bas  sur 6 et un  Retard   DP Bas    sur 10  l alarme  se d  clenche lorsque le PointRose reste au dessous de  5 C pendant 10 minutes au moins et se  d  sactive d  s que le PointRose remonte au dessus de  1  C       Stop   PR Bas   il est possible d activer l alarme pour un PointRose bas pour
42.  frig  rant   o   il se refroidit en contact avec le circuit frigorifique  permettant     l humidit   s y trouvant de condenser  L humidit   condens  e est s  par  e et expuls  e dans le  demister   s  parateur    L air froid passe par l   changeur air air o   il c  de une partie du froid accumul      l air chaud en entr  e   permettant ainsi    ce dernier un pr   refroidissement    Le circuit frigorifique n  cessaire    ces op  rations se compose essentiellement d un compresseur  frigorifique  d un condensateur et de l   vaporateur   galement appel     changeur air   r  frig  rant       260000006000    5 3 SCHEMA FONCTIONNEL  refroidissement    air                                            Compresseur frigorifique  Condensateur   R  cepteur de liquide   Filtre d  shydrater   T  moin du liquide   Vanne thermostatique   TEX  Evaporateur   S  parateur de liquide  Electrovanne by pass gaz chaud  Pressostat gaz frigorig  ne        Pg   Py  Echangeur air air    Direction du flux d   air                                                     2  S  parateur      le condensat     3  Accumulateur de le condensat   Vanne service   vacuation le condensat    15  Filtre m  canique le condensat   Electrovanne   vacuation le condensat    7  R  sistance du carter du compresseur  Ventilateur du condensateur   Vanne de service   Instrument   lectronique   ADS93 o DMC20   23 Sonde du temp    T1  amp  T6 ADS93   T1   T8 DMC20   22 Groupe by pass  optionnel       gt  Direction du flux de gaz r  fri
43.  l eau de refroidissement     La vanne pressostatique est un dispositif de contr  le op  rationnel   La fermeture du circuit d eau par la vanne pressostatique ne peut pas   tre utilis  e comme  fermeture de s  curit   pour les interventions sur l installation     REGLAGE       La vanne pressostatique est r  gl  e lors des essais sur une valeur couvrant 90   des applications       peut se produire que les conditions de fonctionnement extr  mes du s  cheur requi  rent un    talonnage plus pr  cis  Lors du d  marrage  il convient de faire contr  ler la pression temp  rature  de condensation et   ventuellement de faire r  gler la vanne    l   aide de la vis situ  e sur la vanne  par un technicien frigoriste    Pour augmenter la temp  rature de condensation  tourner la vis de r  glage dans le sens inverse  des aiguilles d une montre  Pour l abaisser  tourner la vis dans le sens des aiguilles d une montre   R  gler la vanne afin de garantir une temp  rature de condensation de 110 113  F  44 45                 5 9 R  CEPTEUR DE LIQUIDE    Install   entre le condensateur et l   vaporateur  il s agit d une r  serve de r  frig  rant en mesure de pallier     une brusque augmentation de la charge thermique sur l   vaporateur  Sur certains mod  les avec  refroidissement    eau  il peut   tre omis car le condensateur exerce   galement la fonction d accumulation   disposant d une grande quantit      l   int  rieur     5 10 FILTRE DESHYDRATEUR    D     ventuelles traces d humidit    de scori
44.  low DewPoint alarm    e Low DP   Delay   Setting in minutes of the delay for the low DewPoint alarm  For example  setting the   Low DewPoint    value on  5  the  Low DP   Diff   value on 6  and the  Low DP   Delay  value on 10  the  alarm is activated when the DewPoint remains below  5  C for at least 10 minutes and goes off as soon as  the DewPoint goes over  1  C       Low DP   Stop   Selecting    YES     it is possible to enable the low DewPoint alarm to switch OFF the dryer   otherwise a simple alarm signal is displayed    e High DewPoint     Setting of the activation threshold for the high DewPoint    e High       Diff    This is the differential temperature to deactivate the high DewPoint alarm    e High DP   Delay   Setting in minutes of the delay for the high DewPoint alarm  For example  setting the   High DewPoint    value on 15  the  High DP   Diff   value on  5  and the  High DP   Delay  value on 10   the alarm is activated when the DewPoint remains over 15  C for at least 10 minutes an goes off as soon  as the DewPoint goes below  10  C    e High DP   Stop   Selecting  YES   it is possible to enable the high DewPoint alarm to switch OFF the  dryer  otherwise a simple alarm signal is displayed    e Condensation     Setting of the activation threshold for the condensing temperature too high    e Condens   Diff    This is the differential temperature to deactivate the high condensing temperature alarm    e Condens   Delay   Setting in minutes of the delay for the al
45.  mat  riau  Des particules d huile de lubrification du compresseur frigorifique sont pr  sentes dans le  r  frig  rant  Ne pas jeter le r  frig  rant dans la nature  L extraire du s  cheur    l aide d outils ad  quats    et le porter dans des centres de r  colte agr    s qui se chargeront de le traiter et de le recycler   8 1 TABLEAU DES ELEMENTS   S  CHEURS TDF145   TDF680    Le tableau des   l  ments ci dessous se r  f  re aux vues   clat  es respectives annex  es au pr  sent manuel     D Groupe d   change    2 Compresseur frigorifique    3  Condensateur  refroidissement    air     4  Ventilateur du condensateur  refroid     air    5  Condensateur  refroidissement    eau   Vanne r  gulation de le condensat  refroid     eau   R  cepteur de liquide   Filtre d  shydrater   T  moin du liquide   Vanne thermostatique   TEX   S  parateur de liquide   Electrovanne by pass gaz chaud  Pressostat gaz frigorig  ne PV   Pressostat gaz frigorig  ne PA   PB    Vanne de service   vacuation du le condensat          amp       65  Q  9  9  0                8                           9        0 0 6     Filtre m  canique du le condensat  Electrovanne   vacuation condensation  Accumulateur de le condensat   Vanne de service   Ch  ssis cabine   Semelle   Ch  ssis cabine   Montant   Ch  ssis cabine   Couvercle   Ch  ssis cabine   Panneau post  rieur  Ch  ssis cabine   Panneau avant  Ch  ssis cabine   Porte du tableau   lectrique  Ch  ssis cabine   Tableau   lectrique  Ch  ssis cabine   Panneau la
46.  max  air entr    psig   barg  174 12   Chute de pression en sortie   Ap  psi   bar  4 4   0 3   Raccordements entr  s   sortie de l air 2 1 2                Type de r  frig  rant R404A       Charge r  frig  rant  oz   kg 125   3 5  D  bit de l air de refroidissement  cfm   m3 h 3240   5500       o                           D  bit de l eau de refroid     60     15                 22       178 05   214 06    D  bit de l eau de refroid     85  F 30  C  gpm mmh  22      578 16   6 5 8 18    Temp  rature maximum del eau       F  C        86 30    Pression maximum del eau      psip barg     1 4540    Chute de pression defeau Ap  ps ba     44 03     Raccordements entr  s   sortie de l eau                    Alimentation   lectrique  V Phase Hz 575 3 60               Consommation        d   lectricit   WI 62   68   51   ss _         gt  70 dbA    40 in  1m     1Se r  f  re    une temp  rature ambiante de 100   F  38   C  et de l air en entr  e    100 psig  7 barg  et 100   F  38   C               4 2 CARACTERISTIQUES TECHNIQUES S  CHEURS SERIES TDF210  TDF285 et TDF340    23 5 8in   600 72 5 8in   1850                                                                                                                        LICICIECIEICIEIEICIETEIETETEIEIETEICIETET LICIEICICIEIEIEICIECIEIETEIEIEIETEIEIEIET                                                                                                                                                                                         
47.  rie TDF210  TDF285 et TDF340  Caract  ristiques techniques s  cheur s  rie TDF420  TDF520 et TDF680    5  DESCRIPTION TECHNIQUE    5 26    Pupitre de commande   Description du fonctionnement   Sch  ma fonctionnel  refroidissement    air    Sch  ma fonctionnel  refroidissement    eau   Compresseur frigorifique   Condensateur  refroidissement    air    Condensateur  refroidissement    eau    Vanne pressostatique pour eau  refroidissement    eau   R  cepteur de liquide   Filtre d  shydrater   T  moin du liquide   Vanne thermostatique   TEX   Evaporateur   S  parateur de liquide   Electrovanne by pass gaz chaud   Echangeur air   air   S  parateur de condensat   Pressostat gaz frigorig  ne P4   Pg   Py   R  sistance du carter du compresseur   ADS93 Controller   DMC20 Air Dryer Controller   Purgeur   lectronique    niveau   Optionnel   Sch  ma   lectrique   TDF145   340   ADS93 Controller  Sch  ma   lectrique   TDF420   680   ADS93 Controller  Sch  ma   lectrique   TDF145   340   DMC20 Air Dryer Controller  Sch  ma   lectrique   TDF420   680   DMC20 Air Dryer Controller    6  ENTRETIEN ET PIECES DE RECHANGE    6 1  6 2    Contr  les et entretien  Pi  ces de rechange conseill  es    7    RECHERCHE DES AVARIES      DEMOLITION    7 1  7 2    Recherche des avaries  D  molition du s  cheur    8  VUES ECLATEES DES ELEMENTS DU SECHEUR    Tableau   l  ments   S  cheurs TDF145   680   Vue   clat  e   S  cheurs TDF145   340   Refroidissement    air  Vue   clat  e   S  cheurs TDF420   680   
48.  sur ce sujet      gt  DMC20  L instrument DMC20 est r  gl   sur un set point trop   lev     voir  paragraphe    Set UP Programmation  du DMC20      gt  L   lectrovanne by pass gaz chaud est bourr  e   contacter un technicien  frigoriste    c          une fuite de gaz cryog  ne   contacter un technicien frigoriste       PointRose trop Bas         Chute de pression dans le  s  cheur trop   lev  e      Le s  cheur   vacue du le  condensat en permanence      Le s  cheur n   vacue pas le  condensat         Pr  sence d eau en ligne        ADS93  La diode      lectroluminescente verte    sur la facade de l instrument est  toujours allum  e et la mention       s affiche    l   cran         ADS93  La diode      lectroluminescente verte    sur la facade de l instrument est  toujours allum  e et la mention  ar s affiche    l   cran               gt  ADS93  V  rifier les c  bles   lectriques de l instrument ADS93 Controller      gt  DMC20  V  rifier les cables   lectriques de l instrument DMC20     gt  V  rifier les c  bles   lectriques de l   lectrovanne by pass gaz chaud       La bobine de l   lectrovanne by pass gaz chaud est grill  e   la remplacer    c   La sonde T1  PointRose  de l instrument   lectronique DMC20 ne rel  ve  pas correctement la temp  rature dans l   vaporateur   pousser la sonde  jusqu    atteindre le fond du puisard d mesure    c   ADS93  L instrument ADS93 est r  gl   sur un Set Point trop bas   voir  paragraphe  Set Up Programmation  de l instrument ADS93     gt
49.  tat liquide  C est essentiellement un   changeur eau gaz r  frig  rant o   l eau de refroidissement  abaisse la temp  rature du gaz r  frig  rant       est indispensable que la temp  rature de l eau    l entr  e ne d  passe pas les valeurs figurant sur la plaque  d identification et de toujours garantir un flux ad  quat  Il est de m  me important de VEILLER A      QUE  L EAU ENTRANT DANS L ECHANGEUR SOIT EXEMPTE D IMPURETES ET D EVENTUELLES  SUBSTANCES CORROSIVES    Le condensateur de chaque s  cheur refroidisse    eau est dimensionne pour satisfaire le demande  sp  cifique du client  temp  rature eau entr  e  augmentation du temp  rature de l eau  etc    Pour cette motif  la consommation d eau peut   tre diff  rente de la valeur figurent sur la plaque d identification  N h  sitez pas     nous contacter pour tout compl  ment d information en ce qui concerne la r  elle consommation d eau  Les  caract  ristiques figurent sur la plaque d identification du s  cheur et du condensateur devront toujours   tre  communiqu  es pour demander des pi  ces de rechange     5 8 VANNE PRESSOSTATIQUE POUR EAU  refroidissement    eau      La vanne pressostatique a pour mission de maintenir    un niveau constant la pression temp  rature de  condensation lorsqu on utilise le refroidissement    l eau  La vanne rel  ve la pression dans le condensateur     l aide d un tube capillaire et r  gle par cons  quent le flux d eau    Lorsque le s  cheur est ferm    la vanne ferme automatiquement le flux de
50.  to be discharged from the dryer with a suitable device  and then delivered to a collection centre where it will be processed to make it reusable     8 1 EXPLODED VIEW   TABLE OF COMPONENTS   DRYERS TDF145 to TDF680    The components table given below refers to the relevant exploded views attached to this manual      1  Heat exchanger group     2  Refrigeration compressor        Condenser unit  AirCooled     4  Condenser unit fan  AirCooled     5  Condenser unit  WaterCooled     6  Condenser water regulating valve  WaterCooled    7  Liquid                    Solid filter dryer    9  Liquid sight   glass   Thermostatic expansion valve   TEX  4  Liquid separator    12  Hot gas by pass solenoid valve    43 Refrigerant pressure switch PV  Refrigerant pressure switch PA   PB   15  Condensate drain service valve    Condensate strainer  Condensate drain solenoid valve  Condensate accumulator  Service valve   Cabinet   Frame   Cabinet   Post panel   Cabinet   Cover panel   Cabinet   Rear panel   Cabinet   Front pad panel  Cabinet   Electric board door  Cabinet   Electric board box  Cabinet   Lateral panel   Control panel   Copper tube immersion well   DewPoint probe  T1   575 460 TF transformer     8      6      6  6  5  amp    3   9   8         C  6        FRAN  AIS          Cher Client     Nous vous remercions de la confiance que vous nous avez accord  e et vous prions de lire attentivement le  pr  sent manuel afin d exploiter au maximum les caract  ristiques de notre produit    Af
51.  up   button on DMC20 pressed for at least 2  seconds    e Check that  compressor ON  led on DMC20 is ON    e Wait a few minutes  then check that the DMC20  is indicating a correct DewPoint temperature and  the condensate drains are regularly cycling    e Ensure the consumption matches with the  values of the data plate    e Check that the rotation direction of the fan  corresponds with the arrows on the  condenser  AirCooled     e Check the operation of the condensate drain  circuit   wait for its first operation    e Allow the dryer temperature to stabilize at the  pre set value    e Slowly open the air inlet valve    e Slowly open the air outlet valve    e Slowly close the central by pass valve of the  system  if installed      e Check the piping for air leakage     3 3 OPERATION AND SWITCHING OFF    NOTE  For short periods of inactivity   max 2   3 days  we recommend that power is maintained to the  dryer and the control panel  This ensures the dryer is available for instant re start without waiting  for the compressor crankcase heater to heat the oil of the compressor        Operation  refer to paragraph 5 1 Control Panel       ADS93 Controller    eCheck the   AirCooled     e Ensure the cooling water flow and temperature is  adequate  WaterCooled     e Check that the mains detection light of the ON OFF  button   pos  1 of the control panel   is ON    e Press the button      ON  of the ON OFF switch    pos  1 of the control panel    e Check that the display of the ADS93 C
52. 1 06   100   090   083     Correction factor for inlet air temperature changes    Inlet air temperature   F 90 100 110 113   Factor  F3    Correction factor for dew point changes    DewPoint   F   Factor  F4    How to find the air flow capacity  How to select a suitable dryer for a given duty   Air flow  __ Nominal  _   Factor x Factor x Factor x Factor Kamin _  Design    Factor                   Factor       Factor  capacity  duty      F1       F2                  F4    wate   air flow      F1       F2     F3              Example  Example    A TDF 340 has a nominal duty of 1200 scfm The procedure here is to list the operating   2040 Nm  h   What is the maximum allowable conditions and then to locate the corresponding  flow through the dryer under the following numerical factors    Operating conditions      Design air flow   1000 scfm  1700 Nm   h         Inlet air pressure   115 psig  7 9 barg       Ambient temperature   110   F  43 3   C       Inlet air temperature   110   F  43 3   C       Pressure DewPoint   38   F  3 3   C     Each item of data has a corresponding numerical  factor as follows         Inlet air pressure   115 psig  7 9 barg       Ambient temperature   110   F  43 3            Inlet air temperature   110   F  43 3   C       Pressure DewPoint   38   F  3 3   C                                                                                Air flow         capacity   1200    1 06 x 0 90 x 0 82    1 00    Std  air     1000   1 06   0 90   0 82   1 00  flow rat
53. 1 Se r  f  re    une temp  rature ambiante de 100   F  38   C  et de l air en entr  e    100 psig  7 barg  et 100   F  38   C                  5 1 PUPITRE DE COMMANDE    La seule interface entre le s  cheur et l op  rateur est le pupitre de commande illustr   ci dessous     ADS93 Controller       MAIN SWITCH               ADS 93 controller           amp     G     Bouton lumineux ON OFF avec  t  moin de pr  sence de tension                                                          T  moin de pr  sence d alarme    ADS93 Controller                Sectionneur g  n  ral                     55    Sch  ma fonctionnel air et gaz  r  frig  rant                                                                               DMC20 Air Dryer Controller                  CH MAIN SWITCH            Dex CE  777766 AN     69956955         mezo    A    DMC20 Air Dryer Controller    Sectionneur g  n  ral                    Sch  ma fonctionnel air et gaz  r  frig  rant                                                                                                                                                                                                    5 2 DESCRIPTION DU FONCTIONNEMENT    Le s  cheur d  crit dans ce manuel se compose essentiellement de deux circuits  Un circuit    air comprim    avec deux   changeurs de chaleur et un circuit frigorifique    L air comprim   en entr  e  chaud et humide  traverse l   changeur air air pour entrer ensuite dans  l   vaporateur    changeur air   r 
54. 30   55  Min  ambient temperature ppod          Nominal inlet air temperature    F     C   Max  inlet air temperature  F     C   Nominal inlet air pressure  psig   barg   Max  inlet air pressure  psig   barg     Inlet outlet air connection Flange 4     150   Refrigerant type R404A    Cooling air capacity     Fenn 7050 1200       _     Cooling water capacity at 60  F 15  C                              749   834 24     Cooling water capacity at 85  F 30  C           mn     1534 43   2078 57   2534 73    Maximum water temperature _       F  C        86 90   Maximum water                       psip barg     7 16 50    Max  water pressure drop       psig barg      1 44 08     Cooling water connections   1 1 2  NPT F   Nominal electric consumption       119   143   179   98   122   149     Compressor power      6   85   10   6   85   10      1 The nominal condition refers to an ambient temperature of 100   F  38   C  with inlet air at 100 psig  7 barg   and 100   F  38   C                                                                         5 1 CONTROL PANEL  The control panels illustrated below are the only dryer operator interface   ADS93 Controller    MAIN SWITCH              ADS 93 controller        ON OFF switch with mains detecting light    A   2  Alarm light                                                                         G  ADS93 Controller       Main switch     5  Air and refrigeration circuit flow diagram                                                          
55. 8AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    3G18AWG    4G14AWG    ema               X    Evos  X       BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH  FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    TF TRANSFORMER   460V SIDE    DEW POINT PROBE    CONDENSING PROBE    TDF340   DMC20 AIR DRYER CONTROLLER    z    2    5 25 1              ELECTRIQUE   PUISSANCE   TDF145                                     SOSIHZIENI ANOINWYAHL NOILOALOYd   AL                                    95 IVLSOSSa3Hd   Ad   NOISS3Hd   1            LVLSOSSAYd   Vd   NOISS3Hd                 LVLSOSSAYd          2001419313 NOILYLN  NWNY      411104                                              4          3933151599   EI         OMVB8LXL               55                    59                      2  09 09                    0     09      JL      OMVPLXL          NOLLO3LOHd     TVWSH3HLINI                                         TD145 210 SET 6 3  10285 SET 8 0    6 TD285 340 SET 10    71  e    h                           gt       lectrique qui se trouve dams le tableau   lec
56. 8in   600 72 7 8in   1850                            CH  Mex    M                                                                                                                                                                        LICICIECICICIEIEICIEIEIEIEICIETETCICIETE                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Air Cooled   59 1 16in   1500    Water Cooled   53 3 4      1365                            Refroidissement    eau  TDF145 TDF185    Refroidissement    air  TDF145 TDF185               MODELE du S  CHEUR                                                        D  bit nom  d air 1  scfm  510 650 510 650   NI min  14500 18500 14500 18500   Nm3 h  870 1110 870 1110   Point de ros  e 1    F     C  38   3   100   38   Temp  rature ambiante minimum    F     C  34 1   Temp  rature nominale air entr      F     C  100   38   113   45   Pression nominale air entr    psig   barg  100   7   Pression
57. 9 110   19  Module puissance DMC20RI 5620100006 1   1    1    1    1   19 110   19  Module d interface 16P pour DMC20   5625NNN100 1    1    1    1    1    19   19   19  Sonde T1 5625NNN035 19   1    1    1  1   Sonde T1   T6 5625NNN037   1     1     1    1    1    19   1     1  119   1    19   19   16   2  12    29  Sonde   2          T4   T5 5625NNNO39   14   1    1    1    1    1    19   1    46   4    49   49   49   4    49   49               7 5625      033 19   1    1   1    1    1    19 119  Sonde   8  refroidis     eau  5625      039 1  1  1    1   19  19   19   19  Prolongation pour sonde 5625      029   2    2    2   2     2    29 126   20  89   8   8    8    8  8   86   86  Optionnel   5    485 230VAC 54905    005 seulement pour communication s  rielle   1  Optionnel   SBC485 115VAC 5490SBC010 seulement pour communication s  rielle   1                                                                                                                                                                                        DESCRIPTION CODE   Bouton ON OFF avec t  moin 5452PLS020  T  moin pour l interrupteur ON OFF   5480      010  T  moin rouge d alarme 54521  0005  Ampoule du t  moin rouge d alarme   5480      005  Filtre du purgeur 64355FF011  Electrovanne du purgeur 64320FF011  Bobine   lectrovan  purgeur 230VAC   64  22    021  Bobine   lectrovan  purgeur 24VAC   64N22MM016  Optionnel EL Purgeur 230VAC   2210      005    Optionnel   El  Purgeur 24VAC   2210BEK005L  Ele
58. AL   ELECTRONIC LEVEL DRAINER    START STOP REMOTE CONTROL    REMOTE ALARM ON INDICATION    TF TRANSFORMER   460V SIDE          T1  DEW POINT    T2  AIR IN    T3  AIR OUT        T4  COMPRESSOR IN        T5  COMPRESSOR OUT    T6  CONDENSING    T7  AMBIENT    T8  WATER IN   WATER COOLED ONLY      gt  gt        q eD          6 1 COMMANDES ET ENTRETIEN    Les op  rations d entretien doivent   tre effectu  es par du personnel qualifi      Avant toute op  ration  s   assurer     e qu aucune pi  ce de la machine ne soit sous tension et que la machine ne puisse pas   tre  rebranch  e au r  seau d alimentation   lectrique    e qu aucune pi  ce de la machine ne soit sous pression et que la machine ne puisse pas   tre  rebranch  e    l installation de l air     Avant de proc  der    toute op  ration d entretien du s  cheur  l   teindre et attendre au moins 30  minutes  Pendant son fonctionnement  le tuyau de raccordement en cuivre entre le compresseur et  le condensateur peut atteindre des temp  ratures   lev  es et donc susceptibles de provoquer des  br  lures     TOUS LES JOURS   e S assurer que les temp  ratures affich  es par l instrument   lectrique sont conformes aux donn  es  figurant sur la plaque d identification    e S assurer du bon fonctionnement des syst  mes d   vacuation de la condensation    e V  rifier que le condensateur soit propre  refroidissement    eau      TOUTES LES 200 HEURES OU UNE FOIS PAR MOIS   e Nettoyer le condensateur avec un jet d air comprim   de 29 psi
59. ED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    START STOP REMOTE CONTROL    REMOTE ALARM ON INDICATION    TF TRANSFORMER   460V SIDE          T1  DEW POINT    T2  AIR IN    T3  AIR OUT    T4  COMPRESSOR IN    T5  COMPRESSOR OUT    T6  CONDENSING    T7  AMBIENT    T8  WATER IN   WATER COOLED ONLY     TDF680   DMC20 AIR DRYER CONTROLLER    2    2    5 26 1              ELECTRIQUE   PUISSANCE   TDF420           59                      YNALVIILLNAA                        SNODINYAHL NOI1O31Otd                            1           1IVLSOSS3Hd     NOISS3Hd 21NVH      LVLSOSS3ud     NOISS3Hd 3SSV8      LVLSOSS3ud     2001419313 NOILYLN  NWNY      411104                                              4          3933151599           OMVB8LXL               55            ZH09 0S                        0     09      dL    9NN9IOv XZ         SMVPLXL    Ad  Vd                          31          8 LVSNACGNOO NOILVNOWAA 3NNVAOHIO313             YNALVeOdVAA LVSN3QNOO                    3NNVAOHLIO3T3                        ZV9 SSVd Ad 3NNVAONHIO313                      SAONVSSINd JINGOW                             d3SVHOI4AJ4V                           V LHOd                                                         245  3GN3931           441009       Ad ZHO9 ASZS E  NVA XZ                      AlddNS       vi
60. Limited acoustic emission   e Dryer and relevant packaging composed of recyclable materials   Not to spoil our commitment  the user should follow the few ecological suggestions marked with  this sign     14         Experienced and trained personnel acquainted with the relevant rules and laws  capable to perform the needed activities and to identify and  avoid possible dangerous situations while handling  installing  using and servicing the machine     1 2 WARNINGS    Compressed air is a highly hazardous energy source    Never work on the dryer with parts under pressure    Never point the compressed air or the condensate drain jet towards anybody    The user is responsible for the installation of the dryer  which has to be executed on the basis of   the instructions given in the    Installation    chapter  Otherwise  the warranty will be voided and   dangerous situations for the personnel and or damages to the machine could occur    Only qualified personnel can use and service electrically powered devices  Before attempting any   maintenance action  the following conditions must be satisfied     e Be sure that no part of the machine is under voltage and that it cannot be connected to the mains    e Be sure that no part of the dryer is under pressure and that it cannot be connected to the  compressed air system   These refrigeration air dryers contain R404A type refrigerant fluid  not considered potential ozone   depleting  Maintenance on refrigeration systems must be carried o
61. ONAL    Instead of the usual drain system  a condensate accumulator plus two solenoid valves controlled by means  of ADS93 Controller or DMC20 Air Dryer Controller   an electronic level controlled drain can be installed as  option    This drain is located after the    demister    condensate separator  instead of standard EVDS  It consists of a  condensate accumulator where a capacitive sensor continuously checking liquid level is placed  as soon as  the accumulator is filled  the sensor passes a signal to the electronic control and  with delay  a diaphragm  solenoid valve will open to discharge the condensate    For a complete condensate discharge the valve opening time will be adjusted exactly for each single drain  operation  Right in time the discharge line will be closed again without wasting compressed air    No condensate strainers are installed  No adjusting is required    A service valve is installed before electronic drain in order to make check and maintenance easily    AT DRYER START UP VERIFY THAT THIS VALVE IS OPEN     CONTROL PANEL    The control panel here illustrated allows checking of drain working   Power   led   drain ready to work   supplied    Alarm        Valve OM          Valve   led   membrane solenoid valve open   discharging  Power O 5 Alarm   blinking led   drain in alarm condition    Test   button   discharge test  keep pushed for 2 seconds        TROUBLE SHOOTING  The troubleshooting and resultant service work should be carried out by qualified  A
62. OND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    TF TRANSFORMER   460V SIDE          DEW POINT PROBE    CONDENSING PROBE    TDF680   ADS93 CONTROLLER    2    7    5 24 1 SCHEMA ELECTRIQUE   PUISSANCE   TDF 420                                                                                         SNODINYAHL NOLLO311OHd                            1           1VLSOSS3Hd     NOISS3Hd ALNVH      LVLSOSS3ud     NOISS3Hd 3SSV8      1LV1SOSS3Md      1001419213 NOI LV LN3NWI TV      411104                                            3d AONALSISAY          S         2  09 06            AOZZIO9Y         9NN9IOv XC    JL      OMVPLXL        gt       lectrique qui se trouve dams le tableau   lectrique     1   1   1                             2  2  010 WC IN    OMVOL9   08901   SAW  L9r 025 0070        SMVOLOP                 OMVOIXE       9MvOLOF       TD680 SET 4 5  TD420 520 SET 16    TD680 SET 20    3 TD420 520 SET 4 0            9MVOIX     do  N31VA4Vd3S LVSNACNOO NOILVNOWAA ANNVWAOYLOATA             AL                          LVSN3QNOO                    3NNVAOHIO3T3             Ad            ZV9 SSVd A8 ANNVAOYLOATS           Vd                       1   X                               XNANINNTNOLNOE         XO                                  Sav  EI V LHOd 310018     
63. REFRIGERATED AIR DRYER  S  CHEUR A CYCLE FRIGORIFIQUE    TDF 145   680    USER   S MAINTENANCE  AND SPARE PARTS MANUAL       MANUEL D INSTRUCTIONS ENTRETIEN     PIECES DE RECHANGE    AIR COOLED  amp  WATER COOLED  REFROIDISSEMENT A AIR  amp  EAU    ISSUE e EDITION 2003  ADS93 Controller  amp  DMC20 Air Dryer Controller       TDM 0145 51 Rev 00 CANADA    Dear Customer     thank you for choosing our product  In order to get the best performance from this product  please read this  manual carefully  In order to prevent erroneous operating conditions and to avoid dangerous situations for  the operator  please note that it s strictly recommended to respect the instructions of this manual and the  safety rules in force in the country where the dryer is installed    This manual refers to refrigerated air dryers model from TDF145 to TDF680 AirCooled and WaterCooled   fitted with ADS93 Controller as standard and DMC20 Air Dryer Controller as option  An optional electronic  level condensate drain system is also available    Before packing for shipment each TDF series refrigerated air dryer is subjected to a rigorous test to ensure  the absence of any manufacturing faults and to demonstrate that the device can perform all the functions  for which it has been designed    Once the dryer has been properly installed according to the instructions in this manual  it will be ready for  use without any further adjustment    The operation of the dryer is fully automatic  and maintenance is limit
64. Refroidissement    air  Vue   clat  e   S  cheurs TDF145   340   Refroidissement    eau  Vue   clat  e   S  cheurs TDF420   680   Refroidissement    eau            A             1 1 DEFINITION DES SYMBOLES UTILISES    Consulter attentivement ce manuel d instructions et d entretien avant d effectuer n importe quelle  op  ration sur le s  cheur     Avertissement    caract  re g  n  ral  risque de danger ou possibilit   de d  t  riorer la machine  faire  particulierement attention    la phrase venant apr  s ce symbole     Risque de danger de nature   lectrique  la phrase signale des conditions susceptibles d entrainer  un danger de mort  Observer attentivement les instructions donn  es     Risque de danger    l  ment ou installation sous pression     Risque de danger    l  ment ou installation pouvant atteindre des temp  ratures   lev  es pendant le  fonctionnement     Risque de danger  interdiction absolue de respirer l air trait   avec cet appareil     Risque de danger  interdiction absolue d utiliser de l eau pour   teindre des incendies    proximit    ou sur le s  cheur     Risque de danger  interdiction absolue de faire marcher la machine avec les panneaux ouverts     Op  rations d entretien et ou contr  le pour lesquels il est n  cessaire de prendre des pr  cautions  particuli  res et devant   tre effectu  es par du personnel qualifi   1     Point de branchement pour l entr  e de l air comprim     Point de branchement pour la sortie de l air comprim       Point de branchem
65. SSURE SWITCH    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    OPTIONAL   ELECTRONIC LEVEL DRAINER    START STOP REMOTE CONTROL    REMOTE ALARM ON INDICATION    TF TRANSFORMER   460V SIDE          T1  DEW POINT    T2  AIR IN    T3  AIR OUT    T4  COMPRESSOR IN    T5  COMPRESSOR OUT    T6  CONDENSING    T7  AMBIENT    T8  WATER IN   WATER COOLED ONLY     5 26 1 ELECTRIC DIAGRAM   POWER   TDF420 to TDF680     DMC20 AIR DRYER CONTROLLER           E                 4                  3GISNI NOILOALOYd T1VINH3HL                   NVA   HOLIMS                               131100 HOSS3HdlNOO   HOLIMS SYNSSAdd    3GIS LA INI HOSS3HdlNOO   HOLIMS 38 0SS3td                   3SVOMNVHO                                SMV8LXL               55            AL  Ad  Vd          XO8 AlddNS 91419411                          dL    ZH09 0S           0     09      9NN9IOv XZ         SMVPLXL                        431009        NVA            vi     lt  TD420 520 SET 4 0            S9MVCLOY 0cS 0CVQ L          o TD680 SET 4 5    3ATVA GION3IOS                   HOJIVHVd3S             3A VA QION31OS          ONOC HOLVHOdVAa             3ATVA GION3 IOS SSVd Ad SVO LOH                        AlddNS                                         AV 1dSIG              OZONA               39018 HOOQ        HOLIMS NIVIN   zas  GN3931  3d ZH09 AS2S                           AlddNS       NOLLO3LOHd     TVWSH3HLINI    SAW0 9r 08901    9MVOLOF
66. T1  doesn t correctly detect the temperature in  the evaporator  Ensure the probe is pushed into the bottom of the  copper tube immersion well      gt  ADS93 The ADS93 Controller is set at a DewPoint too low   see  ADS93  Set Up  section      gt  ADS93 The ADS93 Controller is faulty   replace it      gt  DMC20 The DMC2O is set at a DewPoint too low   see DMC20  Get  Up  section      DMC20 The DMC2O is faulty  replace it    c   The hot gas by pass solenoid valve is blocked   contact a refrigeration  engineer         Excessive pressure drop within  gt  The DewPoint is too low   the condensate is frozen and blocks the air  the dryer  flow   see specific point   c   Check for throttling of any flexible connection hoses  if used      gt  The  Demister  condensate separator is clogged   clean or replace it        The dryer continuously drains  gt  The drain solenoid valve s  is jammed   remove and clean it   condensate  c   Verify the electric wiring     gt  ADS93 The ADS93 Controller is faulty   replace it     DMC20 The DMC2O is faulty   replace it         The dryer doesn t drain the  gt  Verify the electric wiring   condensate  c   The condensate drain service valve s  is closed   open it    c   The condensate drain strainer s  is clogged   remove and clean it    c   The drain solenoid valve s  is jammed   remove and clean it    c   The coil of the condensate drain solenoid valve s  burned out   replace it      gt  ADS93 The ADS93 Controller is faulty   replace it    c   DMC20 On
67. activation      has been activated         DMC20 The condensing  temperature is too high         DewPoint is too high     1  The ambient temperature is too high or the room aeration is  insufficient   provide proper ventilation  AirCooled     2  The condenser unit is dirty   clean it  AirCooled     3  The condenser fan s  doesn t work   see specific point  AirCooled     4 The cooling water is too hot   restore the nominal condition     WaterCooled     5  The cooling water flow is insufficient   restore the nominal condition   WaterCooled     6  There is a refrigerant leak in the evaporator   contact a refrigeration  engineer     c   Reset the pressure switch pressing the button on the controller itself    verify the dryer for correct operation      gt  The PA pressure switch is faulty   contact a refrigeration engineer to  replace it     c   Check which of the following has caused the alarm    1  The ambient temperature is too high or the room aeration is  insufficient   provide proper ventilation  AirCooled     2  The condenser unit is dirty   clean it  AirCooled     3  The condenser fan s  doesn t work   see specific point  AirCooled     4 The cooling water is too hot   restore the nominal condition   WaterCooled     5  The cooling water flow is insufficient   restore the nominal condition   WaterCooled      c   The dryer is OFF   switch it ON    c   The refrigeration compressor doesn t work   see specific point      gt  The inlet air is too hot   restore the nominal condit
68. anch  e    l installation de l air     p    DEFAUT CONSTATE CAUSE PROBABLE   INTERVENTION SUGGEREE      Led   teint  c   V  rifier si est pr  sente l alimentation   lectrique   c   V  rifier les c  bles   lectriques  int  rieurement et ou ext  rieurement     gt  V  rifier si le circuit imprim   int  rieur    purgeur n est pas endommag        Appuyer le poussoir pour le  gt  La vanne de service positionn   avant le purgeur est ferm  e   l ouvrir   Test  le condensant ne purge   Le s  cheur n est pas sous pression   r  tablir le conditions nominales   pas   gt  L   lectrovanne est d  fectueuse   remplacer le purgeur      gt  Le circuit imprim   int  rieur est endommag     remplacer le purgeur            purgeur d  charg   le  gt  Le capteur capacitif est sale   ouvrir le purgeur et nettoyer le tuyau en  condensant seulement quand plastique du capteur   est appuie sur le touche Test     Le purgeur d  charg    gt  La vanne est                      ouvrir le purgeur et nettoyer   continuellement air    gt  Le capteur capacitif est sale   ouvrir le purgeur et nettoyer le tuyau en  plastique du capteur         Purgeur en condition alarme    Le capteur capacitif est sale   ouvrir le purgeur et nettoyer le tuyau en  plastique du capteur   c   La vanne de service positionn   avant le purgeur est ferm  e     l ouvrir     gt  Le s  cheur n est pas sous pression   r  tablir le conditions nominales   c   L   lectrovanne est d  fectueuse   remplacer le purgeur     REMARQUE   Quand le purgeu
69. arm when the condensing temperature is too  high  For example  setting the  Condensation    value on 60  the  Condens   Diff   value on  5  and the   Condens   Delay  value on 10  the alarm is activated when the condensing temperature remains over   60  C for at least 10 minutes and goes off as soon as it falls  below  55  C  NOTE  the condensing  temperature     too high alarm    will switch OFF the dryer    e Start at Power Up   At factory setting of    NO     each time the dryer is powered ON it will always enter the  Stand by condition  Selecting    YES     the dryer will continue the function it was performing at the moment  of the power cut off  Stand by if it was in Stand by conditions  ON if it was ON     SELECTING YES THE USER WILL BE RESPONSIBLE FOR THE INSTALLATION OF PROPER PROTECTION FOR  POSSIBLE SUDDEN POWER RESTORATION TO THE DRYER    e Recovery After     Automatic alarms recovery  Selecting    NO     in case of the activation of an alarm that  stopped the dryer  the operator will have to stop the alarm switching the dryer to stand by condition   pressing the  15  button for at least 2 seconds   If    YES    is selected  the dryer will revert to it   s previous its  operational condition as soon as the nominal conditions will be restored    SELECTING YES THE USER WILL BE RESPONSIBLE FOR THE INSTALLATION OF PROPER PROTECTIONS  FOR POSSIBLE SUDDEN POWER RESTORATION TO THE DRYER     e Peripheral No    Assignment of a physical address for the DMC20  in case this i
70. art up after a long period of inactivity  or following maintenance operations     follow the instructions given below     The start up must be performed by qualified personnel     Sequence of operations  refer to paragraph 5 1 Control Panel       ADS93 Controller    e Ensure that all the steps of the    Installation    chapter  have been observed    e Ensure that the connection to the compressed  air system is correct and that the piping is  suitably fixed and supported    e Ensure that the condensate drain pipes are  properly fastened and connected to a collection  system or container    e Ensure that the by pass system  if installed  is  open and the dryer is isolated    e Ensure that the manual valves of the condensate  drain circuit are open    e Remove any packaging and other material which  could obstruct the area around the dryer    e Activate the mains switch    e Close the main switch   pos  4 on the control  panel    e Check that the mains detection light of the ON OFF  button   pos  1 of the control panel   is ON    e Wait at least two hours before starting the dryer   compressor crankcase heater must heat the oil  of the compressor     e Ensure the cooling water flow and temperature is  adequate  WaterCooled     e Switch ON the dryer the button      ON  of the  ON OFF switch   pos  1 of the control panel    e Check that the display of the ADS93 Controller is  ON    e Wait a few minutes  then check that the ADS93  is indicating a correct DewPoint temperature and  t
71. ation  du DMC20     gt  DMC20  L instrument DMC20 est d  fectueux   le remplacer      gt  DewPoint trop Bas   le condensat congel     voir paragraphe sur ce sujet       gt  Le s  cheur est   teint   l allumer       Le groupe by pass laisse passer de l air n   tant pas trait     le fermer     gt  Le s  cheur n   vacue pas le condensat   voir paragraphe sur ce sujet     PointRose trop Haut   voir paragraphe sur ce sujet     REMARQUE  quand le d  faut est   limin    purge l eau pr  sence sur  le r  cepteur de liquide    la sortie du s  cheur   pour  cette op  ration ouvrir le vanne de service  voir pos  19  du tableau des   l  ments du vues   clat  es      c   V  rifier les c  bles   lectriques de la sonde T1  DewPoint Point de ros  e  de  l instrument ADS93    c   La sonde T1  DewPoint Point de ros  e  de l instrument   lectronique  ADS93 est d  fectueuse   la remplacer     gt  L instrument ADS93 est d  fectueux   le remplacer     c   V  rifier les c  bles   lectriques de la sonde T2  condensation  de  l instrument ADS93    c   La sonde T2  condensation  de l instrument   lectronique ADS93 est  d  fectueuse   la remplacer     gt  L instrument ADS93 est d  fectueux   le remplacer              DMC20  Le message  Sonde   Une des sondes de relev   de la temp  rature est d  fectueuse   afficher    FAULT   DMC20     s affiche sur le    une succession de toutes les temp  ratures   le param  tre indiqu   par          correspond    la sonde d  fectueuse       gt  V  rifier que le connec
72. c power  verify that the voltage and the frequency available on the  mains correspond to the data reported on the data plate of the dryer  In terms of voltage  a  5  tolerance is  allowed    The dryer comes with a box for the connection to the mains    The mains socket must be provided with a mains magneto thermal differential breaker  1An 0 03A    adjusted on the basis of the consumption of the dryer  see the nominal values on the data plate of the  dryer     The cross section of the power supply cables must comply with the consumption of the dryer  while also  taking into account the ambient temperature  the conditions of the mains installation  the length of the  cables  and the requirements enforced by the local Power Provider        It is mandatory to ensure the connection to the ground terminal     2 9 CONDENSATE DRAIN    The condensate is discharged at the same pressure of the air entering the dryer   Never point the condensate drain jet towards anybody     The dryer is supplied already featuring the connections to the condensate collection plant by means of two   one if optional electronic level drain is installed  ports for 3 8 in  10 mm  in diameter flexible plastic tubing   The condensate drain operates through two solenoid valves  In order to avoid clogging of the solenoid  valve  the condensate to be discharged is previously filtered by means of strainers  The solenoid valve coil  is operated by ADS93 Controller or DMC20 Air Dryer Controller  optional electronic 
73. changes color according to the percentage of humidity in the  refrigerant  It signals an unusual and dangerous increase in the moisture content of the refrigeration circuit     5 12 THERMOSTATIC EXPANSION VALVE   TEX    The purpose of this valve is to regulate the refrigerant flow across the dryer relative to the heat load  It   s  operation is to maintain a constant condition in the evaporator  regardless of load variations  to provide the  correct dew point and prevent liquid refrigerant returning to the compressor     5 13 EVAPORATOR    Also called air to refrigerant heat exchanger  this range of dryers is of the type featuring a copper tubing  package included in a steel shell  The refrigerant circulates inside the copper tubing  while the air to be  cooled down  conveyed by a proper number of diaphragms  goes through the full length of the evaporator   The evaporation of the liquid accumulated in the condenser takes place in this part of the circuit  During the  evaporation phase  the refrigerant absorbs the heat of the compressed air in the other side of the  exchanger     5 14 LIQUID SEPARATOR    It prevents the return of liquid refrigerant to the compressor separating droplets not evaporated from the  refrigerant flow     5 15 HOT GAS BY PASS SOLENOID VALVE    This valve is located between the pressure side of the compressor and the terminal side of the evaporator   Its purpose is to avoid that in conditions of low thermal charge in the dryer  low air flow or relative
74. ctrovanne by pass 64120SS015  Electrovanne by pass 64120SS020  Bobine   lectrovan  by pass 230VAC   64N22MM060  Bobine   lectr vanne by pass 24VAC  64  22    045  Compresseur frigorifique 5015340004  Compresseur frigorifique 5015340006  Compresseur frigorifique 5015340011  Compresseur frigorifique 5015340008  Compresseur frigorifique 5015340012  Compresseur frigorifique 5015340018  Compresseur frigorifique 5015340023  Compresseur frigorifique 5015340026  Vanne thermostatique     TEX 64130SS220  Vanne thermostatique     TEX 64130SS222  Vanne thermostatique     TEX 64130SS226  Vanne thermostatique     TEX 64130SS250  Vanne thermostatique     TEX 64130SS255  Vanne thermostatique     TEX 64130SS260  Pressostat PV  refroidis     air    5655NNNO90  Pressostat PB     PA 5655      095  Demister grillage cond  s  parateur  5856  0145005  Demister grillage cond  s  parateur  5856  0185005  Demister grillage cond  s  parateur  5856  0285005  Demister grillage cond  s  parateur  5856  0420005  Demister grillage cond  s  parateur  5856TD680005  SEZ     Interrupteur principal 5450SZN100  SEZ     Interrupteur principal 5450SZN105  Q1   Interrupteur automatique   54443SM050  Q1   Interrupteur automatique   54443SM060  Q2   Interrupteur automatique   54443SM030  Q2   Interrupteur automatique   54443SM045  Q3   Interrupteur automatique   54443ST020  Q4   Interrupteur automatique   54441C6005  Q4   Interrupteur automatique   54442C6015  Q1  amp  Q2   Contact auxiliaire 5490CAX050       T  l  ru
75. dried air cannot be used for respiration purposes or for operations leading to  direct contact with foodstuff    This dryer is not suitable for the treatment of dirty air or of air containing solid particles     2 1 TRANSPORT    Once the integrity of the packaging is verified  place  the unit near to the installation point and unpack the  contents     e Keep the dryer always in vertical position  Turning it  upside down some parts could be irreparably  damaged       Even when packaged  keep the machine protected  from severity of the weather     The packaging materials are recyclable     Each single material must be properly  disposed in a manner complying with the 31 1 2in   800mm    rules in force in the destination country        2 2 INSTALLATION SITE    Particular care is required in selecting the installation site  as an improper location could  jeopardize the proper operation of the dryer    This unit is not suitable for use in an explosive atmosphere  where risk of fire could exist  or in the  presence of gaseous or solid polluting material     Don t use water to extinguish fire on the  dryer or in the surrounding area     Minimal installation requirements            min  40 in  min  1m    e Select a clean dry room  free from dust  and  protected from atmospheric disturbances           e The supporting area must be smooth  horizontal  and able to hold the weight of the dryer     e Minimum ambient temperature  34   F  1   C    e Maximum ambient temperature  113  F  45  
76. e     temperatures   the parameter indicated with         corresponds to faulty probe       gt  Be sure that the probe extension connector of faulty probe is correctly    inserted in DMC20       Check the probe extension connection between DMC20 and terminal board      gt  Check connection between probe and terminal board     gt  If the fault persists  replace probe and or probe extension    NOTE  If the faulty probe is T1  DewPoint  the hot gas by pass  solenoid valve is always on  If any other probe is faulty the  dryer will run correctly even if there is an alarm condition     7 2 DISMANTLING OF THE DRYER    If the dryer is to be dismantled  it has to be split into homogeneous groups of materials        Part    Material       Refrigerant fluid    R404A   HFC  Oil       Canopy and Supports    Carbon steel  Epoxy paint       Refrigeration Compressor    Steel  Copper  Aluminum  Oil       Heat Exchanger and Condensate Separator    Copper  Steel       Condenser Unit    Aluminum  Copper  Carbon steel             Pipe Copper  Fan Aluminum  Copper  Steel  Valve Brass  Steel       Insulation Material    Synthetic gum without CFC  Polyurethane       Electric cable    Copper  PVC          Electric Parts       PVC  Copper  Brass       We    recommend to comply with the safety rules in force for the disposal of each type of material     The chilling fluid contains droplets of lubrication oil released by the refrigerating compressor  Do not  dispose this fluid in the environment  Is has
77. e    940 scfm  1597 Nm  h      This is the   1280 scfm  2175 Nm   h      Therefore  maximum flow rate that the dryer can accept the model suitable for the conditions above is TDF    under these operating conditions  420  1480 scfm  2520             nominal duty      2 5 DRYER CONNECTION LAY OUT                                                       TDF145 to TDF420 to  TDF340 TDF680   in   mm   in   mm   A 10 5 8   270  B 19 1 4   490 21 1 4   540  C 19 11 16   500  D 4 7 8   125  E 3 7 8   100  F 3 7 8   100  G 28 3 4   730 33 1 2   850  H 3 7 8   100  TDF145 to TDF340 TDF420 to TDF680   3 78   100          2 6 CONNECTION      THE COMPRESSED AIR SYSTEM    Operations to be performed by qualified personnel  Never operate with plants under pressure    The user is responsible to ensure that the dryer will never be operated with pressure exceeding  the nominal values  Eventual over pressure could be dangerous both for the operator and the  machine     The temperature and the amount of air entering the dryer must comply with the limits reported on the data  plate  In case of treatment of air at particularly high temperature  the installation of an aftercooler could be  necessary  The cross section of the connecting piping  which must be free from dust  rust  chips and other  impurities  must be consistent with the flow rate of the dryer  In order to facilitate the maintenance  operations a by pass group can be installed  as shown in the following illustration        Dryers Connecti
78. e  s affiche    l   cran    Pour allumer le s  cheur  appuyer constamment pendant 2 secondes minimum sur la touche  14   Marche  s  cheur   REMARQUE  A l int  rieure du DMC20 il y a un temporisateur qui ne permet pas de faire  r  partir le compresseur avant 2 minutes apr  s l arr  t  Le Point de Ros  e s affiche    l   cran tandis qu il  est possible de s  lectionner l affichage des param  tres suivants sur celle inf  rieure     Air  gt O   temp  rature de l air en entr  e en   C   Air    O   temp  rature de l air en sortie en   C   Compr  LP   temp  rature de l aspiration du compresseur  c  t   bas pression  en   C  Compr HP    temp  rature du refoulement du compresseur  c  t   haut pression  en   C    Condens    temp  rature de condensation en   C   Milieu   temp  rature ambiante en   C   Eau    O   temp  rature d entr  e de l eau de condensation  refroidissement    eau  en  C  Travail   temps de travail du s  cheur en heures    Le param  tre    afficher sur la ligne inf  rieure de l   cran est s  lectionn   en appuyant sur les touches  12  ou   13   Lorsqu une alarme est active sur la liste des param  tres pouvant   tre affich  s  le Point de Ros  e est    galement affich    Pour   teindre le s  cheur  appuyer constamment pendant 2 secondes minimum sur la  touche  15     Arr  t s  cheur                 5 21 2 ALARMES    Tout   tat d alarme est signal   par le t  moin clignotant  9     Alarme en cours  et le DMC20   met un signal  sonore intermittent afin d attirer l attent
79. e d installer un r  frig  rant final    Les tuyaux de raccordement doivent avoir une section proportionnelle au d  bit du s  cheur et ne doivent pas    tre rouill  s  pr  senter d   barbures ou toute autre impuret      A fin de faciliter les op  rations d entretien  un groupe by pass est install   comme illustr   ci dessous        S  cheurs Branchements  9  A  in   mm   TDF145 to TDF185 2 1 2  NPT   F 19 11 16   500  TDF210 to TDF340 Flange 3   150 19 11 16   500  TDF420 to TDF680 Flange 4   150 19 11 16   500                                  Le s  cheur a   t   con  u en prenant certaines pr  cautions de fa  on    r  duire les vibrations susceptibles de  se produire pendant son fonctionnement  Par cons  quent  il est conseill   d utiliser des tuyaux de  raccordement prot  geant le s  cheur contre d   ventuelles vibrations provenant de la ligne  tuyaux flexibles   joints anti vibrations  etc       2 7 RACCORDEMENT AU R  SEAU D EAU DE REFROIDISSEMENT  refroidissement    eau     Op  rations n  cessitant du personnel qualifi    Toujours travailler sur des installations n   tant pas  sous pression  L utilisateur doit veiller    ce que le s  cheur ne soit pas utilis      des pressions  sup  rieures    celles figurant sur la plaque  D   ventuelles surpressions peuvent provoquer de  s  rieux dommages aux op  rateurs et    la machine     La temp  rature et la quantit   d eau de refroidissement doivent   tre conformes aux limites figurant dans le  tableau des caract  ristiques techniq
80. e l air    refroidir traverse l   vaporateur sur toute sa longueur  achemin   par un nombre ad  quat de  diaphragmes    L   vaporation du liquide qui s est form   dans le condensateur s effectue dans cette partie du circuit   Pendant la phase d   vaporation  le cryog  ne tend    absorber la chaleur de l air comprim   pr  sent de l autre  c  t   de l   changeur     5 14 S  PARATEUR DE LIQUIDE    II emp  che le retour de r  frig  rant liquide au compresseur en s  parant les gouttelettes non   vapor  es de la  ligne de gaz     5 15 ELECTROVANNE BY PASS GAZ CHAUD    Plac  e entre le c  t   comprimant du compresseur et la partie terminale de l   vaporateur  elle a pour but  d   viter  en cas de faible charge thermique du s  cheur  flux limit   d air ou air pas excessivement chaud    que des temp  ratures inf  rieures    32  F  0  C  ne soient atteintes dans l   vaporateur  D   ventuelles  temp  ratures inf  rieures    32  F  0  C  permettent la formation de glace dans l   vaporateur  ce qui bouche le  passage de l air et  dans des cas extr  mes  provoque la rupture de l   vaporateur  La bobine de  l   lectrovanne est command  e par l instrument   lectronique     5 16 ECHANGEUR AIR   AIR    Tous les s  cheurs de cette gamme sont dot  s d un   changeur air air    faisceau tubulaire en cuivre     l int  rieur d un tube en acier  L objectif de cet   changeur consiste    faire c  der la chaleur de l air comprim    en entr  e    celui froid en sortie  Les avantages de cette solution son
81. e or both drain times on DMC20 are set at zero seconds     see DMC20  Set Up  section    c DMC20 The DMC2O is faulty   replace it    c   The DewPoint is too low   the condensate is frozen   see specific  point       Water within the line  c   The dryer is OFF   switch it ON   c   Untreated air flows through the by pass system  if installed    close  the by pass     gt  The dryer doesn t drain condensate   see specific point   c   The DewPoint is too high   see specific point     NOTE   Once the problem is solved  it is mandatory to drain the  water collected in the exit chamber of the dryer     opening  the service valve  see pos  19 in the exploded view of the  dryer s component          ADS93 The green led on  gt  Check the electric wiring of the T1 probe  DewPoint  of the ADS93  the front of the ADS93 device   Controller is always ON and   Probe T1  DewPoint  of the ADS93 electronic device doesn t work       appears on the display  properly   replace it   c   The ADS93 Controller is faulty   replace it         ADS93 The green led on  gt  Check the electric wiring of the T1 probe  DewPoint  of the ADS93    the front of the ADS93 device       Controller is always ON and ar    Probe T2  Condensing  of the ADS93 electronic device doesn t work    appears on the display  properly   replace it   c   The ADS93 Controller is faulty   replace it         DMC20  DMC20 display    Probe  gt  One of the temperature probes is faulty   display in sequence all the    Fault    2  5    messag
82. ed to few controls and some cleaning  operations  as detailed in the following chapters    This manual must be kept available for future reference and it should be considered as an integral  part of the relevant dryer    Due to continuous technical evolution  we reserve the right to introduce any necessary change without  notice                                         IDENTIFICATION PLATE  The product identification plate   on the back of the dryer  shows  all the primary data of the  machine    gt  Model  Upon installation  fill in the table s       gt  ae         copying the data shown on the                     This data Nominal Flow Rate   Nominal Flow Rate              must always be provided to the Max Air Pressure   gt         Air Pressure       manufacturer or to the dealer Max Inlet Air Temp    Max Inlet Air Temp   when information or spares are Ambient temp    gt  Ambient Temp      needed  even during the Refrigerant  gt  Refrigerant  LL  type kg  1 alteration of Relig ss PER m Pa RENE       the identification plate will void   Electric Supply      Electric Supply  ____ ph V Hz  the warranty rights  Electric Nominal Power   Electric Nominal Power WIA  Fuse Max    gt    Fuse              Manufactured   Manufactured  3 CE  WARRANTY CONDITIONS    For 12 months from the installation date  but no longer than 14 months from the delivery date  the warranty  covers faulty parts  which will be repaired or replaced free of charge  except the travel  hotel and restaurant  expe
83. ent      la programmation     5 21 DMC20 AIR DRYER CONTROLLER         cran    cristaux liquides r  tro   clair   9  T  moin alarme en cours   T  moin compresseur en marche 10  Touche essai   vacuation condensat  T  moin ventilateur en marche 11  Touche acc  s    la programmation  T  moin EV by pass actif 12  Touche augmentation    T  moin EV   vacuation condensat Evaporateur actif 13  Touche diminution  T  moin EV   vacuation condensat S  parateur actif 14  Touche marche s  cheur  T  moin r  sistance huile carter actif 15  Touche arr  t s  cheur  T  moin s  cheur en Attente Commande    Ge SL ONE OT SE Io       Le DMC20 contr  le toutes les op  rations  les alarmes et les param  tres de fonctionnement du s  cheur   Gr  ce    l affichage    32 caract  res  il est en mesure de fournir toutes les conditions fonctionnelles  En cas  d anomalie  une s  rie de messages dans la langue choisie permettra de d  celer rapidement le  dysfonctionnement et d   y pallier     5 21 1 MESSAGES AFFICHES    Lorsque le sectionneur g  n  ral est enclench    tous les caract  res de l   cran du DMC20 sont activ  s  pendant 2 secondes environ  La version du logiciel s affiche  puis les deux lignes de l   cran prennent leurs  fonctions respectives    Lorsque le s  cheur est en stand by  pause   le message  Attente Commande  s affiche    l   cran  les  t  moins  r  sistance huile carter  et  s  cheur en Attente Commande  sont actifs  Si la commande     distance est utilis  e   Attente Commande    Distanc
84. ent pour l   vacuation de la condensation    vaporateur      YE Point de branchement pour l   vacuation de la condensation  s  parateur de condensation      RE Point pour le raccordement entr   eau de refroidissement  refroidissement a eau      AAA Point pour le raccordement sortie eau de refroidissement  refroidissement    eau      Op  rations pouvant   tre effectu  es par le personnel charg   de faire fonctionner la machine      condition qu il soit qualifi   1     REMARQUE   Phrase devant attirer l attention mais qui donne pas d instructions pour la s  curit       Nous sommes efforc  s de concevoir et de fabriquer le s  cheur en respectant l environnement     e R  frig  rants sans CFC   e Mousses isolantes expans  es sans l aide de CFC   e Pr  cautions visant    r  duire la consommation d   nergie   e Niveau de pollution sonore limit     e S  cheur et emballage r  alis  s    partir de mat  riaux recyclables   Pour ne pas annihiler nos efforts  l utilisateur est invit      suivre les simples avertissements de  nature   cologique portant ce symbole    1 H s agit de personnes jouissant d une certaine exp  rience  poss  dant une formation technique et au courant des normes et des  r  glementations  en mesure d effectuer les interventions n  cessaires et de reconna  tre et   viter tout   ventuel danger lors de la manutention  de  l installation  de l utilisation et de l entretien de la machine     1 2 AVERTISSEMENTS    L air comprim   est une source d   nergie tr  s dangereuse 
85. ernal timer that cannot allow to restart the compressor before 2 minutes after the  switch off     The upper line of the display will show the DewPoint  The following parameters can be selected and  displayed on the lower line     Air  gt O   temperature of the incoming air in   C   Air    O   temperature of the outgoing air in   C   Compr  LP   suction temperature of the compressor  low pressure side  in   C  Compr         discharge temperature of the compressor  high pressure side  in   C    Condens    condensing temperature in        Ambient   ambient temperature in   C   Water  O  inlet temperature of the cooling water  WaterCooled  in   C  Working   operating time of the dryer in hours    The parameter to be displayed on the lower line is selected pressing the  12  or  13  keys   In alarm condition  the list of the parameter to be displayed will include the DewPoint   To switch OFF the dryer  keep the  15  button  Dryer Stop  pressed for at least 2 seconds     5 21 2 ALARMS    Any alarm condition is indicated by the flashing of the  9  led  Alarm  and the DMC20 activates a buzzer  tone in order to alert the operator  The operator can stop the buzzer by pressing any key   The cause of the alarm will be displayed on the upper line of the LCD display    Intervention   Intervention  Alarm Message Cause  Point Delay  Thermal electrical protection  Protection Comp  of the compressor o   No delay The dryer is stopped  Protection Fan Thermal electrical o   N   delay Th   diyapis
86. eront  r  par  es ou remplac  es gratuitement  Sont exclus les frais de transport  de voyage  de logement et de  nourriture de nos techniciens  La garantie exclut toute responsabilit   pour des dommages directs ou  indirects    des personnes  des animaux et des objets caus  s par un usage ou un entretien inad  quat et se  limite seulement et uniquement aux vices de fabrication  Le droit    la r  paration sous garantie est  subordonn   au respect des instructions d installation  d utilisation et d entretien figurant dans le pr  sent  manuel  La garantie devient imm  diatement nulle en cas de modification ou alt  ration du s  cheur  m  me si  minime  Lors de la demande d intervention sous garantie  il est n  cessaire de communiquer les donn  es  figurant sur la plaque d identification du produit     1  NORMES DE SECURITE    D  finition des symboles utilis  s  Avertissements  Utilisation correcte du s  cheur    2  INSTALLATION    Transport   Lieu d installation   Sch  ma d installation   Facteurs de correction   Sch  ma de branchement du s  cheur   Branchement    la prise d air comprim     Raccordement au r  seau d eau de refroidissement  refroidissement    eau   Branchement    l installation   lectrique   Evacuation de la condensation    3  MISE EN SERVICE    Pr  liminaires    la mise en service  Premi  re mise en service  Marche et arr  t    4  CARACTERISTIQUES TECHNIQUES    Caract  ristiques techniques s  cheur s  rie TDF145 et TDF185  Caract  ristiques techniques s  cheur s 
87. erre     2 9 EVACUATION DE LA CONDENSATION    La condensation est   vacu  e    la m  me pression que l air qui entre dans le s  cheur   Ne pas diriger le jet d   vacuation de la condensation vers des personnes     Le s  cheur est livr   pr  t      tre raccord      l installation de collecte du le condensat    l aide de deux  dispositifs de fixation  un purgeur   lectronique    niveau peut   tre install   comme optionnel  pour tuyau en  plastique flexible de 3 8 in  10 mm  de diam  tre    L   vacuation du le condensat est assur  e par deux   lectrovannes prot  g  es par un filtre m  canique  le  condensat pr  lev   par le s  parateur et par l   vaporateur est tout d abord filtr   pour   viter que les    lectrovannes ne se bloquent pour   tre ensuite expuls    Les bobines des   lectrovannes sont command  es  par l instrument   lectronique  ADS93 Controller   DMC20 Air Dryer Controller     Raccorder les dispositifs d   vacuation du le condensat    une installation ou un r  cipient de collecte et les  fixer correctement    Les dispositifs d   vacuation ne peuvent pas   tre introduits dans des circuits sous pression     Ne pas laisser la condensation s   vacuer dans l atmosph  re    Se La condensation s  par  e du s  cheur contient des particules d   huile laiss  es par le compresseur  dans l air   Eliminer la condensation conform  ment aux normes en vigueur dans le pays d   installation   Il est conseill   d   installer un s  parateur eau huile permettant d   acheminer toute la c
88. es pouvant   tre pr  sentes dans l installation frigorifique ou des  d  p  ts pouvant se former apr  s une utilisation prolong  e du s  cheur  tendent    limiter la lubrification du  compresseur et    boucher les vannes d   expansion et capillaires    Le filtre d  shydrater situ   avant le tuyau capillaire sert    retenir toutes les impuret  s et      viter qu elles  continuent de circuler dans l installation     5 11 T  MOIN DU LIQUIDE    Install   sur la conduite de liquide air r  frig  rant  il permet de v  rifier le passage du liquide  Dot   d une  pastille r  alis  e dans un compos   chimique particulier  dont la couleur change en fonction du pourcentage  d humidit   dans le cryog  ne  il signale une augmentation anormale et dangereuse du contenu d eau     5 12 VANNE THERMOSTATIQUE   TEX    Ele se charge d adapter dans des limites raisonnables le rendement de l installation aux variations de  charge thermique  Elle bloque l alimentation du frigorig  ne    une surchauffe constante de la vapeur sortant  de l   vaporateur  rendant ainsi active   quel que soit l   tat de fonctionnement   toute la surface d   change  de l appareil et en emp  chant dans le m  me temps que du liquide non vaporis   retourne dans le  compresseur     5 13 EVAPORATEUR    Egalement appel     changeur air r  frig  rant  il s agit pour cette gamme de s  cheurs d un   vaporateur     faisceau tubulaire en cuivre    l int  rieur d un tube en acier  le cryog  ne circule dans les tubes en cuivre  tandis qu
89. es sont   chang  es en mode ASCII dans le format suivant     Baudrate   9600 Data bit   7 Stop bit   1 Parity   even          BASE DE DONNEES  La liste des param  tres de dialogue avec leur description  le type et l adresse des donn  es sur le DMC20  figurent dans le tableau ci dessous     Adresse  Registre    0000  R    Donn  e Description Type    PointRose emp  rature de Point de Ros  e   sonde T1 Signed Integer  Air  gt O emp  rature de l   air en entr  e   sonde T2 Signed Integer 0001   R    Air    O Temp  rature de l air en sortie   sonde T3 Signed Integer 0002  R    Compr BP Temp  d aspiration compresseur  c  t   bas pression    sonde T4 Signed Integer 0003   R  Compr HP  Condens  Temp  rature de condensation   sonde T6 Signed Integer 0005   R  Eau  gt 0             d entr  e eau de condensation  refroid    cau   sonde T8     Signed Integer      0006 R    Ambiance Temp  rature ambiante   sonde T7 Signed Integer 0007   R  Langue  PdC PointRose Intervention Ev by pass Signed Integer 0201   R W          Protection Vent  bit   12 Yes       0102 6   R  0102 7  R    Alarme active pour interv  prot  therm    lect  ventil   refroid     air   Protection Comp     Alarme active pour interv  prot  therm    lect  compr   refroid     air  bit   12 Yes                      PointRose  Temps Purge     Pause Purge               Pause Purge S  Contraste Ac  Min PointRose         PointRosc    PointRose Bas  Diff PR Bas  Retard  PR Bas    PointRose Haut    Point d intervention de l alarme p
90. et une longue dur  e de vie  Le groupe pompant  int  gralement mont   sur des ressorts  amortisseurs  att  nue sensiblement le niveau de bruit et la transmission des vibrations    Le moteur   lectrique est refroidi par le gaz r  frig  rant aspir    qui traverse les enroulements avant d arriver  dans les cylindres de compression  La protection thermique int  rieure prot  ge le compresseur contre les  temp  ratures et les courants trop   lev  s  Le r  tablissement de la protection est automatique lorsque les  conditions nominales de temp  rature se repr  sentent     5 6 CONDENSATEUR  refroidissement    air     Le condensateur est l   l  ment du circuit o   le gaz provenant du compresseur est refroidi et condens   en  passant    l   tat liquide       se pr  sente sous forme de circuit de tuyaux en cuivre     l int  rieur duquel circule  le gaz  se trouvant dans un paquet lamellaire en aluminium  Le refroidissement se produit gr  ce    un  ventilateur axial tr  s efficace qui  en le comprimant  force l air se trouvant    l int  rieur du s  cheur dans le  paquet lamellaire  Il est indispensable que la temp  rature de l air ambiant ne d  passe pas les valeurs  figurant sur la plaque  Il est   galement extr  mement important que LA BATTERIE SOIT TOUJOURS  EXEMPTE DE DEPOTS DE POUSSIERE ET DE TOUTES AUTRE IMPURETE     5 7 CONDENSATEUR  refroidissement    eau     Le condensateur est l   l  ment du circuit o   le gaz provenant du compresseur est refroidi et condens   en  passant    l  
91. g  2 barg  maximum  de l int  rieur  vers l ext  rieur  effectuer la m  me op  ration de l ext  rieur vers l int  rieur  faire extr  mement  attention    ne pas plier les ailettes en aluminium du paquet de refroidissement  refroidissement     eau        Fermer la vanne manuelle d   vacuation de la condensation  d  visser le filtre m  canique et le  nettoyer avec de l air comprim   et un pinceau  Remonter le filtre en le serrant correctement et  ouvrir de nouveau le robinet manuel    e Ces op  rations   tant achev  es  v  rifier le bon fonctionnement de la machine     TOUTES LES 1000 HEURES OU UNE FOIS PAR AN   e Contr  ler que toutes les vis de l installation   lectrique soient serr  es correctement et que tous les  branchements de type    Faston    soient dans la bonne position    e Contr  ler l   tat des tuyaux flexibles d   vacuation de la condensation et les remplacer    ventuellement    e Ces op  rations   tant achev  es  v  rifier le bon fonctionnement de la machine     6 2 PIECES DETACHEES CONSEILLEES                                                          TDF   ADS93 Controller TDF   DMC20 Air Dryer Controller   DESCRIPTION CODE 145   185   210   285   340   420   520   680   145   185   210   285   340   420   520   680  Ventilateur  refroidis     air  5250355090   1 1 1 1 1 2  2 1 1 1 1 1 2   2  Ventilateur  refroidis     air  5250355100 2 2  ADS93 Controller 5620110002   14   1    1    1    1    19   19   1   Module affichage DMC 20 5620100005 1  1  1    1   19  1
92. g  rant    5 4 SCHEMA FONCTIONNEL  refroidissement    eau      2                  EE                                C       Em SSS         lt              EE                                 Compresseur frigorifique  2  S  parateur de le condensat   Condensateur  3  Accumulateur de le condensat   R  cepteur de liquide Vanne service   vacuation le condensat  Filtre d  shydrater  5  Filtre m  canique le condensat   T  moin du liquide Electrovanne   vacuation le condensat  Vanne thermostatique   TEX  7  R  sistance du carter du compresseur  Evaporateur Vanne pressostatique pour eau  S  parateur de liquide Vanne de service   Electrovanne by pass gaz chaud Instrument   lectronique   ADS93 o DMC20  Pressostat gaz frigorig  ne PA   PB     Sonde du temp    T1  amp  T6 ADS93   T1   T8 DMC20  Echangeur air air  22 Groupe by pass  optionnel       280000006000    Direction du flux d air    gt  Direction du flux de gaz r  frig  rant          5 5 COMPRESSEUR FRIGORIFIQUE    Le compresseur frigorifique est la pompe de l installation o   le gaz provenant de l   vaporateur  c  t    pression basse  est comprim   jusqu    la pression de condensation  c  t   pression   lev  e     Les compresseurs utilis  s  provenant tous de grands constructeurs  sont con  us pour des applications o    se manifestent des rapports de compression   lev  s et de gros   carts de temp  rature    La construction compl  tement herm  tique garantit une parfaite   tanch  it   du gaz  une grande efficacit      nerg  tique 
93. harges    ause between two Condensate Separator discharges  Adjustment of the Display contrast    Signed Integer  Signed Integer    Signed Integer  Signed Integer  Signed Integer  Signed Integer    Signed Integer  Signed Integer  Signed Integer  Signed Integer  Signed Integer  Signed Integer  Signed Integer  Signed Integer  bit   1 Yes  bit   1 Yes  bit   1 ON  bit   0 Local  1 Remote  bit   1 Yes  bit   1 Yes    emperature of intervention for the too low DewPoint alarm    grerrmssusgememmpie  LIT 5 o   wo      gt      T           19 13  3 Si         c      BRE REI                lt  45  gt      ols s    2          315      3 3 m  5                  9  o eis 9  o     ks  weu               3   5 5 5    2    2     9    2     NAME 9    8                   E 3     o      9     o Es  3852      9  5                 9  16 S EAE            lt  10  2 5 5   alo ko Ke            5 5   U ko IO                            D              3             emperature of intervention for the too high DewPoint alarm  Differential temp  for the too high DewPoint alarm       ntervention temperature for too high condensation temperature alarm    nit address for serial communication    resence of an alarm that has stopped the dryer   resence of an alarm   tatus of the condenser fan control pressure switch  Status of the Remote ON OFF switch                                  D     D     oo      o  lt     lt   5       3  e     S            3 go        E SA     2  T            E         55 15      2      
94. he condensate drains are regularly cycling   e Ensure the consumption matches with the  values of the data plate    e Check that the rotation direction of the fan  corresponds with the arrows on the  condenser  AirCooled     e Allow the dryer temperature to stabilize at the  pre set value    e Slowly open the air inlet valve    e Slowly open the air outlet valve    e Slowly close the central by pass valve of the  system  if installed      e Check the piping for air leakage     DMC20 Air Dryer Controller   e Ensure that all the steps of the  Installation  chapter  have been observed    e Ensure that the connection to the compressed  air system is correct and that the piping is  suitably fixed and supported    e Ensure that the condensate drain pipes are  properly fastened and connected to a collection  system or container    e Ensure that the by pass system  if installed  is  open and the dryer is isolated    e Ensure that the manual valves of the condensate  drain circuit are open    e Remove any packaging and other material which  could obstruct the area around the dryer    e Activate the mains switch    e Close the main switch   pos  2 on the control  panel    e Check that  crankcase heater  and  Stand by   leds on DMC20 are ON    e Wait at least two hours before starting the dryer   compressor crankcase heater must heat the oil  of the compressor     e Ensure the cooling water flow and temperature is  adequate  WaterCooled     e Switch ON the dryer keeping the  Dryer Start
95. in de ne pas travailler dans de mauvaises conditions et d   viter tout danger pour les op  rateurs  nous  vous rappelons qu il est indispensable d observer scrupuleusement les directives figurant dans le pr  sent  manuel ainsi que les normes de pr  vention des accidents en vigueur dans le pays o   le mat  riel est utilis     Le pr  sent manuel se r  f  re aux s  cheurs    cycle frigorifique de mod  le TDF 145 680  refroidissement     air et    eau  avec l instrument   lectronique ADS93 comme standard or l instrument   lectronique DMC20  comme optionnel    Avant d   tre emball    chaque s  cheur    cycle frigorifique de la s  rie TDF subit une s  rie de tests s  v  res   Cette phase sert    v  rifier l absence de vices de fabrication et que la machine remplit correctement les  fonctions pour lesquelles elle a   t   con  ue  Apr  s l avoir correctement install   conform  ment aux  instructions donn  es dans le pr  sent manuel  le s  cheur est pr  t    l emploi et n a besoin d aucun r  glage   Son fonctionnement est enti  rement automatique  son entretien se limite    quelques contr  les et aux  op  rations de nettoyage d  crites en d  tail dans les chapitres suivants    Le pr  sent manuel doit   tre conserv   afin de pouvoir le consulter    tout moment et fait partie  int  grante du s  cheur que vous avez achet      En raison de l   volution permanente de la technique  nous nous r  servons le droit d apporter toute  modification n  cessaire sans pr  avis  N h  sitez pas    nous
96. inal  values  It is important TO KEEP THE UNIT FREE FORM DUST AND OTHER IMPURITIES     5 7 CONDENSER  WaterCooled     The condenser is the element in which the refrigerant gas coming from the compressor is cooled and  condensed into a liquid  The condenser is a water refrigerant heat exchanger comprised of a copper tube  bundle contained in a carbon steel vessel    The temperature of the inlet water must not exceed the nominal values  Reliable condenser performance is  dependant on adequate water flow and THAT THE WATER ENTERING THE EXCHANGER IS FREE OF  IMPURITIES AND IS CHEMICALLY NEUTRAL    The condenser unit of each WaterCooled dryer is sized in order to satisfy the customer requirements  i e   inlet water temperature  water temperature rise  etc   Due to this the water consumption indicated in  technical features can be different from the real value  Do not hesitate to contact us and ask for the real  water consumption at your condition  For ordering a condenser unit as spare part  it is necessary to specify  the dryer label data and the condenser unit label data     5 8 CONDENSER WATER REGULATING VALVE  WaterCooled     The condenser water valve regulates water flow to keep the condensing pressure temperature constant  under varying dryer load conditions   When the dryer stops the valve automatically closes the cooling water flow     The condenser water regulating valve is an operating control device   The closure of the water regulating valve should not be used as a sec
97. incipe  d  termine ce qui suit                                                                                 D  bit D  bit  dair   1200 x 1 06 x 0 90 x 0 82 x 1 00          1000   1 06   0 90   0 82   1 00            princip    940 scfm  1597 Nm   h      C est le   1280 scfm  2175 Nm  h   gt  Pour  d  bit d air maximum que le s  cheur est en satisfaire ces crit  res  s  lectionner le mod  le  mesure de supporter aux conditions de travail ci  TDF420  dont le d  bit nominal de principe est de    dessus  1480 scfm  2520 Nm    h            2 5 SCH  MA DE BRANCHEMENT DU S  CHEUR                                           TDF145 to TDF420 to  TDF340 TDF680   in   mm   in   mm   A 10 5 8   270  B 19 1 4   490 21 1 4   540  C 19 11 16   500  D 4 7 8   125  E 3 7 8   100  F 3 7 8   100  G 28 3 4   730 33 1 2   850  H 3 7 8   100  TDF145 to TDF340 TDF420 to TDF680    3 718   100                2 6 BRANCHEMENT    LA PRISE D   AIR COMPRIME    Op  rations n  cessitant du personnel qualifi    Toujours travailler sur des installations n   tant pas    N sous pression  L utilisateur doit veiller    ce que le s  cheur ne soit pas utilis      des pressions  sup  rieures    celles figurant sur la plaque  D   ventuelles surpressions peuvent provoquer de  s  rieux dommages aux op  rateurs et    la machine     La temp  rature et la quantit   d air entrant dans le s  cheur doivent   tre conformes aux limites figurant sur la  plaque  En cas d air particuli  rement chaud  il peut s av  rer n  cessair
98. ion de l op  rateur  En appuyant sur une touche quelconque   l op  rateur a la possibilit   de faire taire la sonnerie d alarme    La cause    l origine de l alarme s affiche sur la ligne sup  rieure de l   cran     Message          Point Retard Raniaraues  d alarme d intervention d interv  q  Protection Comp          dE protection Aucun Le s  cheur s arr  te  therm    lect  du compresseur  Protection Vent  Disp  de protection                Aucun Le s  cheur s arr  te   refroidis     air    therm    lect  du ventilateur    PA Pressostat haut pression                30 5 barg    Condens  HAUT ele de condens  50   70   C 89 0  ka Le s  cheur s arr  te  trop   lev  e  sonde T6  r  glable  Point de Ros  e Point de Ros  e trop bas  40   0   C 0 5 20 min   L op  rateur s  lectionne si  BAS  sonde T1  r  glable arr  ter le s  cheur  Point de Ros  e Point de Ros  e trop haut 10   20   C 0 5 30 min   L op  rateur s  lectionne si  HAUT  sonde T1    r  glable arr  ter le s  cheur  Sonde FAULT Une des sondes est            Le s  cheur n est pas  d  fectueuse arr  t      MEMORISATION DES ALARMES    Avec    Auto D  marrage  et    Reprise Apres    d  sactiv  s   mis sur    NO      toute alarme ayant provoqu    l arr  t du s  cheur et toute anomalie sur l une des sondes  Sonde en Panne  reste m  moris   sur le DMC20   Pour effacer la m  moire de l alarme  appuyer pendant 2 secondes minimum sur la touche  15      Arr  t  s  cheur   et appuyer pendant 2 secondes minimum sur la touche  14     
99. ions   install an  aftercooler before the dryer      gt  The inlet air flow rate is higher than the capacity of the dryer   reduce  the flow rate   restore normal conditions    c   The fan s  doesn t work   see the specific point  AirCooled       gt  The ambient temperature is too high or the room aeration is  insufficient   provide proper ventilation  AirCooled     c   The condenser unit is dirty   clean it  AirCooled       The cooling water is too hot   restore the nominal condition   WaterCooled     c   The cooling water flow is insufficient   restore the nominal condition   WaterCooled     c   The dryer doesn t drain the condensate   see specific point      gt  ADS93 The ADS93 Controller green led is always ON   see  specific point    c   ADS93  The ADS93 Controller is set at a DewPoint too high   see  ADS93  Set Up  section    c   DMC20 The led    alarm    is ON and DMC20 display  Probe Fault   message   see specific point      gt  DMC20 The DMC2O is set        DewPoint too high   see DMC20  Get  Up  section    c   The hot gas by pass solenoid valve is blocked   contact a refrigeration  engineer    c   There is a leak in the refrigeration circuit   contact a refrigeration  engineer         DewPoint too low  c   ADS93 Verify the wiring of the ADS93 Controller    c   DMC20 Verify the wiring of the DMC20      gt  Verify the wiring of the hot gas by pass solenoid valve      gt  The coil of the hot gas by pass solenoid valve burned out   replace it    c   The DewPoint probe  
100. ire red  marrer le s  cheur de fa  on    ce que la r  sistance carter r  chauffe l huile du    compresseur        Marche  voir paragraphe 5 1 Pupitre de Commande      ADS93 Controller    e V  rifier que le condensateur est propre   refroidissement    air     e V  rifier que le d  bit d eau de refroidissement est  pr  sent  refroidissement    eau     e V  rifier que le t  moin de pr  sence de la tension  du bouton lumineux ON OFF   rep  re 1 du  pupitre de commande   est allum         Appuyer sur la touche    I   ON  du bouton  lumineux ON OFF   rep  re 1 du pupitre de  commande     e V  rifier que l   cran de l instrument ADS93  s allume    e Attendre quelques  l instrument ADS93  temp  rature de service    e Alimenter le compresseur d air     e La fonction antigel est garantie par l intervention  de l   lectrovanne de by pass gaz chaud signal  e  par la diode   lectroluminescente verte sur la  facade de l instrument ADS93   rep  re 3 du  pupitre de commande     minutes  v  rifier que  indique la bonne    DMC20 Air Dryer Controller    e V  rifier que le condensateur est propre   refroidissement    air     e V  rifier que le d  bit d eau de refroidissement est  pr  sent  refroidissement    eau     e V  rifier que les t  moins    r  sistance huile carter     et  s  cheur en Attente commande  du DMC20  sont allum  s    e Appuyer sur la touche  marche s  cheur  du  DMC20 pendant 2 secondes minimum    e V  rifier que le t  moin  compresseur en marche   du DMC2O est allum      e At
101. le PC et le r  seau des DMC20 doit   tre r  alis  e    l aide d un module  d interface de type SBC485  pouvant   tre achet   s  par  ment   voir liste des pi  ces d  tach  es  de fa  on     convertir le signal de type RS232  PC  en un signal de type RS485  DMC20   La ligne RS485 se compose  d un c  ble    deux conducteurs et peut atteindre une longueur maximum de 2000 m  tres  avec des longueurs  importantes  plus de 100 m  tres   il est conseill   d utiliser un c  ble en poly  thyl  ne torsad   et blind      Pour une bonne transmission des donn  es  il est indispensable de terminer le c  ble de la ligne RS485 avec  une r  sistance de 120 ohms   watt  comme sur la figure ci dessous         SBC 485    RS 485    Controller        Air Dryer Controller                  Air Dryer Controller    BEA EDOM    EE      ASSIS IIS 7777777 i                 905555                2009005  D  I re                          PERIPHERAL No  255 PERIPHERAL No  2 PERIPHERAL No  1  CONNEXIONS COM   PC SBC485 SBC485 DMC20  25      RS232 25        RS232 9 pin RS485 DATA connecter  Ecran   pin 1 n c  A   pin 1 Borne A  Tx   pin 2 pin 2 B   pin 2 Borne B  Rx   pin 3 pin 3 Ecran   pin 4         RTS        4 pin 4  CTS   pin 5 pin 5  GND   pin 7 pin 7  PROTOCOLE    Le transfert des donn  es entre le PC et le SBC485 est contr  l   par un signal de type RTS  Le protocole  utilis   pour la communication est un sous ensemble de MODICON MODBUS 1  MB1   o   sont support  es  les fonctions 0 3 et 06  Les donn  
102. level drain without  strainer     Connect and properly fasten the condensate drain to a collecting plant or container    The drain cannot be connected to pressurized systems     Don t dispose the condensate to the environment    The condensate collected in the dryer contains oil particles released in the air by the compressor   Dispose the condensate in compliance with the local rules    We suggest the installation of water oil separator where to collect all the condensate coming from  compressors  dryers  receivers  filters  etc     3 1 PRELIMINARY OPERATIONS    Verify that the operating parameters match the nominal values reported on the data plate of the  dryer  voltage  frequency  air pressure  air temperature  ambient temperature  etc        gt  8    Before delivery  each dryer is submitted to accurate tests simulating real operating conditions   Nevertheless  the unit could be damaged during transportation  We therefore suggest that you check the  integrity of the dryer upon arrival and to keep it under close watch during the first hours of operation     The start up must be performed by qualified personnel    It s mandatory that the engineer in charge will adopt safety operational conditions complying with  the local safety and accident prevention requirements    The same engineer will be responsible for the proper and safe operation of the dryer    Never operate the dryer if their panels are not in place     GE    3 2 FIRST START UP    At the first start up  or for st
103. ller      Check that the DewPoint indicated on the  DMC20 is within range    e Switch OFF the air compressor    e After few minutes  switch OFF the dryer keeping  the  Dryer Stop  button on DMC20 pressed for at  least 2 seconds     NOTE   Taking into account possible variations of operating conditions  flow rate  temperature of the  incoming air  ambient temperature  etc   a DewPoint temperature within 0  C and  10  C  32  F    to 50  F  can be considered normal     During the operation  the refrigeration compressor will run continuously   The dryer must remain ON when ever compressed air is being used  even if the air compressor only loads    intermittently     4 1 TECHNICAL FEATURES OF DRYERS SERIES TDF145 and TDF185    23 5 8in   600 72 7 8in   1850                      SE  NN  Al                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
104. low rates and to not  require special maintenance  It is also easily accessible by removing the blind flange located at the end of  the exchanger group     5 18 REFRIGERANT PRESSURE SWITCH        Pg   Py    To provide operational safety and protection for the dryer  a series of pressure switches are installed in  refrigerant circuit     PB  Low pressure controller device on the suction side of the compressor  This switch operates if the  pressure drops below the pre set value  The values are automatically reset when the nominal  conditions are restored     Calibrated pressure  Stop 14 5 psig  1 0 barg    Restart 72 5 psig  5 0 barg     PA  This high pressure controller device  located on the delivery side of the compressor  is activated  when the pressure exceeds the pre set value  It features a manual resetting button mounted on the  controller itself     Calibrated pressure  Stop 440 psig  30 5 barg    Manual Reset    PV  Condenser unit fan control pressure safety switch placed at the outlet side of condenser unit  It  keeps the condensation temperature pressure constant within preset limits  AirCooled      Calibrated pressure   Stop 260 psig   104   F  18 barg   40   C   Restart 320 psig   122   F  22 barg   50  C     5 19 COMPRESSOR CRANKCASE HEATER    At low temperatures  when the compressor starts  oil can be drawn into the refrigeration circuit and liquid  hammering could occur  To prevent this  an electrical resistance heater is installed in the suction side of the  c
105. ls below the pre set temperature  the hot gas solenoid valve is activated  The range can be  adjusted at level 2    e DewPoint Diff    This is the differential temperature to switch OFF the hot gas by pass solenoid valve  For  example  setting on 2 the  DewPoint Set  value and on 1 the  DewPoint Diff   value  the hot gas by pass solenoid  valve is activated when the DewPoint falls below 2  C and is switched OFF when the DewPoint rises over 3  C    e E Drain Time   Setting of the condensate drainage time of the solenoid valve located before the evaporator         Drain Pause   Setting of the pause of time between two successive condensate drainage of the  solenoid valve located before the evaporator    e S Drain Time   Setting of the condensate drainage time of the solenoid valve located on the condensate separator   e S Drain Pause   Setting of the pause time between two successive condensate drain cycles of the valve  located on the condensate separator    e Display Contrast   Adjustment of the contrast of the LCD display  depending on the observation angle   the illumination  the ambient temperature  etc     LEVEL 2   e Min DewPoint   This is the minimum value of the adjustable range for  DewPoint Set  at level 1    e Max DewPoint   This is the maximum value of the adjustable range for  DewPoint Set  at level 1    e Low DewPoint     Setting of the threshold activating the alarm for the low DewPoint    e Low      Diff    This is the differential temperature to deactivate the
106. ly cold air   the temperature inside the evaporator will drop below 32   F  0   C   Temperature below 32   F  0   C  would  eventually allow the formation of ice inside the evaporator  with the consequent clogging of the air port and   in the worst of the cases  the rupture of the evaporator itself  The coil of the solenoid valve is piloted by the  electronic controller     5 16 AIR TO AIR HEAT EXCHANGER    All the dryers of this range are provided with an air to air heat exchanger featuring a copper tubing package  included in a steel shell  The purpose of this exchanger is the transmission of the heat of the incoming air to  the exiting cold air  The benefits of this solution are basically two   the incoming air is partially cooled down   therefore the chilling system can be sized for a lower thermal drop  thus allowing a 40 50  energy saving   moreover  as cool air will never reach the compressed air circuit  no condensate will form on the external  surface of the piping     5 17    DEMISTER    CONDENSATE SEPARATOR    The cold air exiting the evaporator goes through the  demister  type condensate separator featuring a  stainless steel net  As the condensate transported by the air gets in contact with the metallic net of the   demister  it is separated and expelled by means of the draining device  The resulting cold and dry air is  then conveyed into the air to air heat exchanger    The  demister  type separator offers the benefit to be highly efficient even with variable f
107. m  I   1 I  Zeg  XE          1 ES     d 5                    f    fo   CL  A A               p    xa     S                                  NOLLO3NNO9             5 26 4 SCH  MA   LECTRIQUE   CONNEXIONS   TDF420   TDF680   DMC20 AIR DRYER CONTROLLER    BU 2  3G18AWG       12 2 Z   NW               gt              12 4 Se 3G18AWG          X   il  js pts                  il  RE                      21   ers        2   10   842 crane               gt   3G18AWG       _        BU 2  3G18AWG  20 16 ERI               BU     YG      BN 1  PS                          L     20   21    SUPPLYED BY CUSTOMER         3   2                   SUPPLYED BY CUSTOMER        49   25     e     26              L    white                         vite T2       red      1 854        white   T3           red   T   1 844      vite         we  TT         TS         white   T5    TT red                   white                         red   T                 TZ                           white                                  BN BROWN  BU BLUE  BK BLACK  YG YELLOW GREEN    COMPRESSOR CRANKCASE HEATER    HOT GAS BY PASS VALVE    EVAPORATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    SEPARATOR COND  DRAIN VALVE  NOT INSTALLED IF OPTIONAL ELECTRONIC DRAINER IS USED    COMPRESSOR PRESSURE SWITCH    PRESS  SWITCH   FAN CONTROL  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    FAN THERMAL PROTECTION  NOT INSTALLED FOR WATER COOLED    OPTION
108. mbiante est trop   lev  e ou le local n est pas suffisamment  a  r     assurer une a  ration ad  quate  refroidissement    air     2  Le condensateur est sale   le nettoyer  refroidissement    air     3 Le ventilateur ne fonctionne pas   voir paragraphe sur ce sujet   refroidissement    air     4 L eau de refroidissement est trop chaude   r  tablir les conditions  figurant sur la plaque  refroidissement    eau     5 Le d  bit d eau de refroidissement n est pas suffisant   r  tablir les  conditions figurant sur la plaque  refroidissement    eau     6         une fuite de gaz cryog  ne dans l   vaporateur   contacter un  technicien frigoriste      gt  R  amorcer le pressostat en appuyant sur la touche situ  e sur le  pressostat   v  rifier le bon fonctionnement du s  cheur     gt  Le pressostat PA est d  fectueux   contacter un technicien frigoriste       gt  D  celer la cause    l origine de l alarme parmi celles   num  r  es ci dessous     1  La temp  rature ambiante est trop   lev  e ou le local n est pas suffisamment  a  r     assurer une a  ration ad  quate  refroidissement    air     2  Le condensateur est sale   le nettoyer  refroidissement    air     3 Le ventilateur ne fonctionne pas   voir paragraphe sur ce sujet   refroidissement    air     4 L eau de refroidissement est trop chaude   r  tablir les conditions  figurant sur la plaque  refroidissement    eau     5  Le flux d eau de refroidissement est insuffisant   r  tablir les conditions  figurant sur la plaque  refr
109. mentaires   Le s  cheur n est pas concu pour traiter de l air sale ou contenant des particules solides     2 1 TRANSPORT    S assurer que l emballage est parfaitement int  gre   placer l unit   pr  s du lieu d installation choisi et  proc  der    l ouverture de l emballage        Maintenir toujours le s  cheur en position  verticale  D   ventuels renversements peuvent  abimer des   l  ments de l unit      e Tenir la machine  quoique emball  e     l abri des  intemp  ries     L emballage est r  alis   dans une mati  re  recyclable  Eliminer l emballage de fa  on    ad  quate et conform  ment aux prescriptions ear ee  en vigueur dans le pays d utilisation              2 2 LIEU D INSTALLATION    Faire particulierement attention lors du choix du lieu d installation  car le bon fonctionnement du  A s  cheur en d  pend   L unit   ne doit pas fonctionner dans des atmosph  res explosives ou pr  sentant des risques  d incendie  ni en pr  sence de substances polluantes gazeuses ou solides     Ne pas utiliser d eau pour   teindre les  X  incendies    proximit   ou sur le s  cheur     Conditions minimums requises pour l installation            min  40 in  min  1m    e Choisir un local propre  sec  sans poussi  re et     l abri des intemp  ries        e Plan d appui lisse  horizontal et en mesure de  supporter le poids du s  cheur     e Temp  rature ambiante minimum de  34  F  1  C    e Temp  rature ambiante maximum de  113  F  45  C                                          e Faire en sor
110. ne  Read carefully the  text related to this sign     Electrical hazard  The relevant text outlines conditions which could result fatal  The related  instructions must be strictly respected     Danger hazard  Part or system under pressure   Danger hazard  Component or system which during the operation can reach high temperature     Danger hazard  It s absolutely forbidden to breath the air treated with this apparatus     Danger hazard  It   s absolutely forbidden to use water to extinguish fire on the dryer on in the  surrounding area     Danger hazard  It   s absolutely forbidden to operate the machine when the panels are not in place     Maintenance or control operation to be very carefully performed by qualified personnel 1     ARIA       T     Compressed air inlet connection point     ARIA                               gt           Es     3     Compressed air outlet connection point     AIR    Condensate drain connections point  evaporator    Condensate drain connections point  condensate separator      AAA Cooling water inlet connection point  WaterCooled           Cooling water outlet connection point  WaterCooled      Operations which can be worked out by the operator of the machine  if qualified 1     Text to be taken into account  but not involving safety precautions     In designing this unit a lot of care has been devoted to the protection of the environment    e CFC free refrigerants   e Foamed insulation parts produced without          e Energy saving design   e 
111. nnel   5 21 7 SERIAL COMMUNICATION    The DMC20 features a RS485 serial port  see terminal A and B on DMC20 back side  allowing the  connection to a network managed by a PC or PLC controller    A maximum of 255 DMC20 units can be connected to the same network    If a PC is used  the connection between the PC and one or more DMC20 requires usage of an SBC485  interface adaptor  can be purchased as accessory   see spare parts list  to be interposed between RS232  serial port and the RS485 bus consisting of two polarized wires  The line can cover 2180yd  2000mt   maximum  for long distance  exceeding 109yd   100m    it is advisable to use a shielded twisted pair  polyethylene cable    For good data transmission  it is imperative that at the cable end a 120 ohm resistor is placed in order to  adapt line impedance  as shown in figure          5     485      5 485    ler  eee ss         lei E oa ORK      OA         227777             me22 n9 pices ne  893  09  ces  PERIPHERAL No  255 PERIPHERAL No  2 PERIPHERAL No  1  CONNECTIONS COM   PC SBC485 SBC485 DMC20  25      RS232 25 pin RS232 9 pin RS485 DATA connector  Shield   pin 1 n c  A   pin 1 A terminal  Tx   pin 2 Pin 2 B   pin 2 B terminal  Rx   pin 3 Pin 3 Shield   pin 4         RTS   pin 4 Pin 4  CTS   pin 5 Pin 5  GND   pin 7 Pin 7    PROTOCOL    The data flow between PC and SBC485 is controlled by RTS signal  The protocol used for communication is  a subset of MODICON MODBUS 1  MB1   functions 03 and 06 only are supported  Da
112. nses of our technician    The warranty doesn t cover any responsibility for direct or indirect damages to persons  animals or  equipment caused by improper usage or maintenance  and it   s limited to manufacturing faults only    The right to warranty repairs is subordinated to the strict compliance with the installation  use and  maintenance instructions contained in this manual    The warranty will be immediately voided in case of even small changes or alterations to the dryer    To initiate repairs during the warranty period  the data reported on the identification plate must be provided     1     2     6     8     SAFETY RULES  1 1 Definition of the Signs Used in this Manual  1 2 Warnings  1 3 Proper Use of the Dryer    INSTALLATION   2 1 Transport   2 2 Installation site  2 3 Installation layout    2 4 Correction factors   2 5 Dryer Connection Lay Out   2 6 Connection to the Compressed Air System   2 7 Connection to the Cooling Water Network  WaterCooled   2 8 Connection to the Mains   2 9 Condensate Drain   START UP   3 1 Preliminary Operations   3 2 First Start Up   3 3 Operation and Switching Off   TECHNICAL CHARACTERISTICS   4 1 Technical Features of Dryers series TDF145 and TDF185  4 2 Technical Features of Dryers series TDF210  TDF285 and TDF340  4 3 Technical Features of Dryers series TDF420  TDF520 and TDF680  TECHNICAL DESCRIPTION   5 1 Control Panel   5 2 Operation   5 3 Flow Diagram  AirCooled    5 4 Flow Diagram  WaterCooled    5 5 Refrigeration Compressor   5
113. ntr    psig   barg  100   7   Pression max  air entr    psig   barg  174 12   Chute de pression en sortie   Ap  psi   bar  4 4   0 3    Raccordements entr  s   sortie de l air Flange 3   150  Type de r  frig  rant R404A  Charge r  frig  rant  oz            180 50 245 7 0 180  5 0 245 7 0    D  bit de l air de refroidissement  cfm   m   h  P 2830   4800     D  bit de Teau de refait                28 08 35840  444    D  bit de l eau de refroid    85     30                                  11 30   121833  Temp  rature maximum de l eau         83     Pression maximum de l eau      psg bag           Im   Chute de pression de                            44 03        Racoordements entr  s   sortie deea        wer   Consommation                N  70   89   89   59   70   78     Consommation        d  lectici   Wl 84   96   106   T4   86   56       gt  70 dbA    40 in  1m        1Se r  f  re    une temp  rature ambiante de 100   F  38   C  et de l air en entr  e    100 psig  7 barg  et 100   F  38   C               4 3 CARACTERISTIQUES TECHNIQUES S  CHEURS SERIES TDF420  TDF520 et TDF680    27 9 16in   700 78 3 4in   2000                                                                                                                                                                                                                                                                                                 m    m   IE    m    m    m          m   D         m          m    m   m  IL   IL  
114. nutes au moins et se d  sactive d  s qu elle retourne au dessous de  55  C   REMARQUE   l alarme pour une temp  rature de condensation trop   lev  e provoque l arr  t du s  cheur    e Auto D  marrage  en d  finissant NO chaque fois que le s  cheur est aliment    celui ci se mettra toujours  en Attente Commande  en s  lectionnant YES  il reprendra la fonction qu il   tait en train d exercer lorsque  l alimentation a   t   coup  e  Attente Commande s il   tait en Attente Commande et allum   s il   tait allum       EN SELECTIONNANT YES  L UTILISATEUR ASSUME LA RESPONSABILITE DE PRENDRE DES  PRECAUTIONS SPECIALES POUR LE POSSIBLE DEMARRAGE A L IMPROVISTE DU SECHEUR     e Reprise Appres     r  amor  age automatique des alarmes  en s  lectionnant NO chaque fois que se d  clenche  une alarme qui provoque l arr  t du s  cheur  il faut que l op  rateur remette    z  ro l alarme en mettant le s  cheur  en Attente Commande  appuyer sur la touche  15  pendant 2 secondes minimum   en s  lectionnant YES  le  s  cheur fonctionnera de nouveau automatiquement lorsque les conditions nominales seront r  tablies     EN SELECTIONNANT YES  L UTILISATEUR ASSUME LA RESPONSABILITE DE PRENDRE DES  PRECAUTIONS SPECIALES POUR LE POSSIBLE DEMARRAGE A L IMPROVISTE DU SECHEUR     e N  P  riph  rique   l adresse physique du DMC20 est attribu  e par l interm  diaire d un port s  rie si elle est  ins  r  e dans un r  seau de transmission de donn  es              TABLEAU DES PARAMETRES DE PROGRAMMATION    Std 
115. oidissement    eau        gt  Le s  cheur est   teint   l allumer    c   Le compresseur frigorifique ne marche pas   voir paragraphe sur ce sujet      gt  L air en entr  e est trop chaud   r  tablir les conditions figurant sur la plaque    installer un r  frig  rant final avant le s  cheur      gt  La quantit   d air en entr  e est sup  rieure au d  bit du s  cheur   diminuer le  d  bit   r  tablir les conditions figurant sur la plaque      gt  Le ventilateur ne marche pas   voir paragraphe sur ce sujet   refroidissement    air     La temp  rature ambiante est trop   lev  e ou le local n est pas suffisamment  a  r     assurer une a  ration ad  quate  refroidissement    air     c   Le condensateur est sale   le nettoyer  refroidissement    air     c   L eau de refroidissement est trop chaude   r  tablir les conditions figurant  sur la plaque  refroidissement    eau     c   Le d  bit d eau de refroidissement est insuffisant   r  tablir les conditions  figurant sur la plaque  refroidissement    eau       gt  Le s  cheur n   vacue pas le condensat   voir paragraphe sur ce sujet      gt  ADS93  La diode   lectroluminescente verte sur la facade de  l instrument ADS93 est toujours allum  e   voir paragraphe sur ce sujet    c   ADS93  L instrument ADS93 est r  gl   sur un Set Point trop   lev     voir  paragraphe  Set Up Programmation  de l instrument ADS93      gt  DMC20  Le t  moin  alarme en cours  est allum   et un message  Sonde en  Panne  s affiche    l   cran   voir paragraphe
116. ompressor  When the system is powered and the compressor is not running  this heater keeps the oil at  the correct temperature  This heater is controlled by a thermostat which prevents overheating the oil     NOTE  The heater must be powered at least a couple of hours before the start up of the refrigeration  compressor     5 20 ADS93 CONTROLLER  Key   It displays the Set Point  activation temp  of the hot gas solenoid valve    La Key   It displays the pause period of the condensate drain   Key   It displays the condensation temp   increments the displayed value   ADS 93 controller Key   Condensate drain test   reduction of the displayed value                           Green LED   Hot gas by pass solenoid valve on   Yellow LED   Condensate drain solenoid valve on   Green LED   Not used        The ADS93 device controls all the functions of the dryer  allowing also the calibration of all the parameters   A probe located at the end of the evaporator pilots the activation of the hot gas by pass solenoid valve  A  second probe  located at the end of the condenser  activate the relevant fan  Moreover  the ADS93  controller acts as a timer controlling the activation at regular intervals of the condensate drain solenoid  valve  During the final test  the following values are factory set     e The hot gas by pass solenoid valve is activated when a temperature below the SetPoint   2  C   36  F  is detected  and it is deactivated at a temperature equal to the SetPoint   Differential  Se
117. ondensation a    vacuer   compresseurs  s  cheurs  r  servoirs  filtres  etc     3 1 PRELIMINAIRES A LA MISE EN SERVICE    S   assurer que les param  tres de fonctionnement soient conformes aux valeurs pr  cis  es sur la  plaque du s  cheur  tension  fr  quence  pression de l air  temp  rature de l air  temp  rature  ambiante  etc       Avant son exp  dition  tout s  cheur est soigneusement test   et contr  l   en simulant des conditions de  travail r  elles  Ind  pendamment des tests effectu  s  l unit   peut subir une d  t  rioration pendant son  transport  Pour cette raison  il est conseill   de contr  ler toutes les parties du s  cheur    son arriv  e et  pendant les premi  res heures de mise en service     La mise en service doit   tre effectu  e par du personnel qualifi      II est indispensable que le technicien charg   de la mise en service applique des m  thodes de travail  s  res et conformes aux l  gislations en vigueur en mati  re de s  curit   et de pr  vention des  accidents    Le technicien est responsable du bon fonctionnement du s  cheur    Ne pas faire marcher le s  cheur avec les panneaux ouverts     GE          3 2 PREMIERE MISE EN SERVICE    p  riode d inactivit   ou d entretien prolong    La mise en service doit   tre effectu  e par du personnel qualifi       Suivre les instructions ci dessous lors de la premi  re mise en service et    chaque remise en service apr  s une    Marche    suivre  voir paragraphe 5 1 Pupitre de Commande      ADS93 Controller  
118. ons  2  A  in   mm   TDF145 to TDF185 2 1 2  NPT   F 19 11 16   500  TDF210 to TDF340 Flange 3     150 19 11 16   500  TDF420 to TDF680 Flange 4     150 19 11 16   500                                  In realizing the dryer  particular measures have been taken in order to limit the vibration which could occur  during the operation  Therefore we recommend to use of connecting pipes able to insulate the dryer from  possible vibrations originating from the line  flexible hoses  vibration damping fittings  etc       2 7 CONNECTION TO THE COOLING WATER NETWORK  WaterCooled     Operations to be performed by qualified personnel  Never operate with plants under pressure    The user is responsible to ensure that the dryer will never be operated with pressure exceeding  the nominal values  Eventual over pressure could be dangerous both for the operator and the  machine     The temperature and the amount of cooling water must comply with the limits indicated on the technical  characteristics chart  The cross section of the connection pipes  preferably flexible  must be free from rust   chips and other impurities  We recommend to use connecting pipes able to insulate the dryer from possible  vibrations originating from the line  flexible hoses  vibration damping fittings  etc       2 8 CONNECTION TO THE MAINS    The connection to the mains  to be carried out by qualified personnel  and the safety systems  must comply with local rules and laws     Before connecting the unit to the electri
119. ontroller is  ON    e Wait a few minutes  then check that the ADS93  is indicating a correct DewPoint temperature and  the condensate drains are regularly cycling    e Switch ON the air compressor     e The anti freezing function is ensured by the  operation of the hot gas by pass solenoid valve   indicated by the glowing of the green light on the  front panel of the ADS93 Controller     condenser for cleanliness    DMC20 Air Dryer Controller    e Check the   AirCooled    e Ensure the cooling water flow and temperature is   adequate  WaterCooled     e Check that  crankcase heater  and  Stand by   leds on DMC20 are ON    e Switch ON the dryer keeping the    Dryer Start up     button on DMC20 pressed for at least 2  seconds    e Check that    compressor ON    led on DMC20 is ON    e Wait a few minutes  then check that the DMC20  is indicating a correct DewPoint temperature and  the condensate drains are regularly cycling    e Switch ON the air compressor    e The anti freezing function is ensured by the  operation of the hot gas by pass solenoid valve   indicated by the glowing of led on DMC20 Air  Dryer Controller     condenser for cleanliness      Switching OFF  refer to paragraph 5 1 Control Panel       ADS93 Controller   e Check that the DewPoint indicated on the  ADS93 is within range    e Switch OFF the air compressor     e After few minutes  switch OFF the dryer pressing  the  ON   OFF  button of the ON OFF switch    pos  1 of the control panel     DMC20 Air Dryer Contro
120. or  the alarm management exist  the user can change the setting of the programmed parameters    Set up parameters are divided in two levels  anybody can access the level 1  while the access to level 2 is reserved  to authorized personnel provided with the password  The password is specified in the last page of this manual    To access to Set up mode the  11   Set up access  button must be depressed for at least 2 seconds  Then  it will be possible to display the desired parameter using the  12  and  13  keys  To modify the displayed  parameter  use the  12  and  13  keys  while keeping the  11  key depressed    During Set up  the upper line of the display will display the selected parameter  while the lower line will show  the current value of the same parameter    To exit Set up mode  press simultaneously the  12  and  13  keys  or wait 20 seconds     NOTE   The character         means    Alarm       DESCRIPTION OF SET UP PARAMETERS   LEVEL 1   e Pass Code    The system asks for the password to access the level 2 of the programming parameters  If  the password is not modified or wrong  only the parameters of level 1 will be accessible  NOTE  The  password can be modified only when the dryer is in stand by  therefore during operation  only the level 1  will be accessible    e Language   It is possible to select the language for the alarm and dialogue messages     e DewPoint Set   Selection of the intervention point of the hot gas by pass solenoid valve  When the  DewPoint fal
121. our un Point de Ros  e trop haut  Diff   PR Haut Diff  rentiel de l alarme pour un Point de Ros  e trop haut  Retard      Haut    Condensation  Dif  1 Condens   Ret  Condens        P  riph  rique  Travail  STOP Alarme Pr  sence d une alarme ayant provoqu   l arr  t du s  cheur  Etat Alarmes  Pressostat Vent  Inter  commande    Etat de l interrupteur de commande    distance  Remote 1 Remote  PointRose BAS  PointRose HAUT    Alarme active pour un Point de Ros  e trop haut  Condens  HAUT    Alarme active suite    temp  de condensation trop   lev  e  STOP Compr BP  STOP Compr HP    Alarme active pour interv  pressostat haute pression r  frig   PA   Sonde FAULT  Stop   PR Bas 0220 0   RW  Siop PR         Auto D  marrage  Reprise Apres   02203 RW  ON OFF DMC20    Etat du DMC20   ON o OFF  Stand by     Remarque  1  S  lection langue   00              01 Anglais   02 Allemand   03 Frangais  R Lecture   W Ecriture          5 22 PURGEUR   LECTRONIQUE    NIVEAU   OPTIONNEL    A l int  rieur de l usuel dispositif de purge  un accumulateur de le condensat plus deux   lectrovannes contr  l  es du  ADS93 Controller ou DMC20 Air Dryer Controller   un purgeur   lectronique    niveau peut   tre install   comme  optionnel  Ce dispositif de purge se trouve apr  s le s  parateur du le condensat     demister   selon le standard  EVDS  Il consiste en un accumulateur de le condensat ou un capteur capacitif qui continuellement contr  le le niveau  de liquide  quand l accumulateur est rempli  le capte
122. pteur 5454TLT116  K   T  l  rupteur 5454TLT016  K   T  l  rupteur 5454TLT125  K   T  l  rupteur 5454TLT025  V   T  l  rupteur 5454TLT111  V   T  l  rupteur 5454TLT011  K   Contact auxiliaire        5490CAX011  K   Contact auxiliaire        5490CAX010  A   Auxiliaire relais 5456REL110  TF     Transformateur 5440TFM020           Transformateur 5440TFM021          Le num  ro se r  f  re    la quantit   install  e    Pi  ce d  tach  e conseill  e     145    19    19    2   2     1     TDF   ADS93 Controller  185   210   285   340   420   520  1 1 1 1 1 1  1    1    1     1  19   1   1 1 1 1 1 1  1    1    1     19 19   14  2 2   2 2   2 2  2  1269126   2     2     2   2    20   20   2     2     2     19   1    1    1  11    16    1 1  1 1  1 1  1 1 1 1  1 1  1 1 1 1  1 1  1 1 1 1  1 1                    TDF   DMC20 Air            Controller    680   145   185   210   285   340   420   520   680    1  19  1  19  2  2   2              2121212121212   2  2    24   2    2    2   2    24   24    29   24   2  126   2   29   24   24    19  1    1    1    1    149   1    1    16    1 1  1 1  1 1   1   1 1 1 1 1  1 1 1   1 1 1 1 1  1 1 1   1 1 1 1 1  1 1 1    1 1 1 1 1 1 1 1    PRECISER LES DONNEES FIGURANT SUR LA PLAQUE D   IDENTIFICATION    pression  pendant son             7 1 RECHERCHE DES AVARIES    expansion en sortant du circuit  peut provoquer des br  lures par    cong  lation et de s  rieuses l  sions s il entre en contact avec les yeux     La recherche d avaries et les   ventuel
123. que intervention    Toute modification de la machine ou de ses param  tres de fonctionnement annulera la garantie si   elle n est pas v  rifi  e et autoris  e au pr  alable par le Constructeur et peut devenir une source de   danger     Ne pas utiliser d eau pour   teindre les incendies    proximit   ou sur le s  cheur        gt  P b P    1 3 UTILISATION CORRECTE DU S  CHEUR    Le s  cheur a   t   concu  fabriqu   et test   uniquement pour s  parer l humidit   normalement pr  sente dans  l air comprim    Toute autre utilisation est    consid  rer incorrecte   Le Constructeur d  gage toute responsabilit   en cas d usage incorrect  l utilisateur est responsable de tout  dommage d  rivant d un usage incorrect   Pour l utiliser correctement  il convient de respecter les conditions d installation et notamment    e Tension et fr  quence d alimentation   e Pression  temp  rature et d  bit de l air en entr  e   e Pression  temp  rature et d  bit de l eau de refroidissement  refroidissement    eau    e Temp  rature ambiante   Le s  cheur est livr   test   et enti  rement assembl    L utilisateur ne doit que veiller    effectuer les  branchements aux installations comme d  crit dans les chapitres suivants   Le seul et unique but de la machine consiste    s  parer l eau et les   ventuelles particules d huile   N pr  sentes dans l air comprim    L air s  ch   ne peut pas   tre utilis   dans un but respiratoire ou pour  des travaux o   il entrerait en contact direct avec des substances ali
124. r  sistance doit   tre activ  e deux heures au moins avant le d  marrage du compresseur  frigorifique           5 20 ADS93 CONTROLLER    Touche   affiche Set Point  temp  intervention   lectrovanne by pass gaz chaud      a Touche   affiche le temps de pause de l   vacuation de la condensation   Touche   affiche temp  de condensation   augmente valeur affich  e     ADS 93 controller    Touche   test   vacuation condensation baisse valeur affich  e     T  moin vert     lectrovanne by pass gaz chaud active     T  moin jaune     lectrovanne   vacuation condensation active   T  moin vert   Pas utilis          L   instrument ADS93 contr  le toutes les fonctions du s  cheur en permettant le r  glage de tous les param  tres    A l aide d une sonde plac  e    la fin de l   vaporateur  l intervention de l   lectrovanne de by pass gaz chaud est   command  e tandis qu une deuxi  me sonde plac  e    la fin du condensateur active son ventilateur  L ADS93   Controller fait en outre office de temporisateur en commandant    intervalles r  guliers l   lectrovanne   d   vacuation de la condensation  Lors des essais  les valeurs d intervention standard suivantes sont d  finies     e Electrovanne by pass gaz chaud   s active lorsqu une temp  rature inf  rieure au Set Point   2  C  36  F  est  relev  e et se d  sactive    une temp  rature   gale au Set Point   Diff  rentiel Set Point  2   2    4  C  36   4     40  F   Pour modifier le Set Point  dans les limites 21 et  5h d  finies lors de la prog
125. r est en alarme  l   lectrovanne s ouvre 7 5 sec toutes les 4 minutes     TDF340   ADS93 CONTROLLER    7    7    5 23 1 SCHEMA ELECTRIQUE   PUISSANCE   TDF145        S         3QNVIAIWOO      3  LldNd                                                 SNODINYAHL NOLLO311OHd                            1           1VLSOSS3Hd     NOISS3Hd 3160 VH      1V1SOSS3MNd     NOISS3Hd 3SSV8      1LV1SOSS3Md     2001419313 NOILYLN  NWNY      411104                                                   3d AONALSISAY      2  09 06            AOZZIO9Y    dL                   d9    Ad    Vd                      YNALVEVdsAS LVSNAGNOO NOILVNOWAA                            WunalvsdodvA3 LVSN3QNOO NOILVNOVAA 3NNVAOHLO3 T3  Qn vHO ZV9 SSVd A8 3NNVAOMW IO3 13                 NIONAL                             XNANINNTNOLNOE                          6SQV    V LHOd                               YNALdNYYALNI       KINO 931009                                                                1           TVWSH3HLINI                                      5 TD145 210 SET 6 3  TD285 SET 8 0    6 TD285 340 SET 10    71  e    h                                  X   d  sav  245    3GN3931    3d ZH09 AS  ZS       Addi    D      lectrique qui se trouve dams le tableau   lectrique                                 xog    A  zas    ZH09    097 6 6    dL    FIELD  INSTALLATION    INSTALLATION      ma    Voir sch    REMARQUE          5 23 2 SCHEMA ELECTRIQUE   AUXILIAIRE   TDF145   TDF340   ADS93 CONTROLLER       z340  d        
126. ram  tre sur celle inf  rieure  Pour quitter la programmation  appuyer simultan  ment sur les touches  12   et  13  ou attendre 20 secondes     REMARQUE   Le symbole         prend la signification de  Alarme      DESCRIPTION DES PARAMETRES DE PROGRAMMATION  NIVEAU 1    e Code d Acc  s    le mot de passe est demand   pour acc  der au niveau 2 des param  tres de  programmation  S il n est pas modifi   ou si le mot de passe est erron    on a uniquement acc  s aux  param  tres du niveau 1  REMARQUE   Le mot de passe peut   tre modifi   seulement avec le s  cheur en   Attente Commande   avec le s  cheur en marche  on n acc  de par cons  quent qu au niveau 1     Langue   il est possible de choisir la langue des messages de dialogue et d alarme     PB Pressostat baisse R404A   1 0 barg  e  STOP Compr        pression r  frig  rant   R404A   145 psig             e        PointRose   sert    s  lectionner le point d intervention      l   lectrovanne de by pass gaz chaud   Lorsque le PointRose descend au dessous de la temp  rature d  finie  l   lectrovanne de by pass s active   La plage de r  glage est limit  e au niveau 2    e Diff  PointRose   c est la temp  rature diff  rentielle d extinction de l   lectrovanne de by pass gaz chaud   en  r  glant par exemple un  Set PointRose  sur 2 et un    Diff  PointRose    sur 1  l   lectrovanne de by pass s active  lorsque le PointRose descend au dessous de 2  C et s   teint lorsque le PointRose remonte au dessus de 3  C       Temps Purge E   d 
127. rammation   appuyer de  fa  on continue sur la touche et modifier la valeur    l aide des touches et     e Electrovanne d   vacuation de la condensation   s active pendant une dur  e de dr  3 secondes  avec  une pause de 60 secondes  Pour modifier la pause entre deux cycles d   vacuation  dans les limites rl  et rh d  finies lors de la programmation   appuyer de fa  on continue sur la touche et modifier la  valeur    l aide des touches 3            SET UP  PROGRAMMATION    Lors de la mise sous tension du s  cheur  l   cran affiche la temp  rature du point de ros  e actuel    En appuyant sur la touche il est possible d afficher la temp  rature de condensation     En appuyant de fa  on continue et simultan  e sur les touches et pendant au moins 5 secondes  on  active la programmation et 21 s affiche    l   cran        Pour s  lectionner le param  tre voulu  appuyer s  quentiellement sur la touche LF         a  Pour modifier la valeur du param  tre s  lectionn    appuyer sur les touches 3 et  7   Tous les param  tres peuvent   tre modifi  s suivant le diagramme figurant ci dessous     EECHER  een  ege  ri   Limite minimum de la pause   vacuation condensation   01599   0   60sec                                        eme              _   sf  mex       9 9         _   oi                         II est possible de sortir de la programmation    tout moment en appuyant sur la touche             Si aucune op  ration n est effectu  e dans les 10 secondes  l instrument sort automatiquem
128. rds inside  be careful not to damage the aluminum  blades of the cooling package  AirCooled     e Close the manual condensate drain valve  unscrew the strainer and clean it with compressed air  and a brush  Reinstall the filter properly tight  then open the manual valve    e At the end  check the operation of the machine     EVERY 1000 HOURS OR YEARLY   e Verify for tightness all the screws of the electric system and that all the spade  Faston  type  connections are in their proper position    e Check the conditions of the condensate drain flexible hoses  and replace if necessary    e At the end  check the operation of the machine     6 2 SUGGESTED SPARE PARTS                                                             TDF   ADS93 Controller TDF   DMC20 Air Dryer Controller   SPARE PARTS CODE 145   185   210   285   340   420   520   680   145   185   210   285   340   420   520   680  Fan unit  AirCooled  5250355090   1 1 1 1 1 2   2 1 1 1 1 1 2 12  Fan unit  AirCooled  5250355100 2 2  ADS93 Controller 5620110002   1     1    1    1     19   1    1    19  Display module DMC20 5620100005 1  1  1    1   19  19   19   19  Power module DMC20RI 5620100006 1    1    1    1    1    1    19   19  Flat 16P for DMC20 5625NNN100 1  1  1    1   19  19   1    19  Probe T1 5625NNN035 19   1    1    1    1   Probe T1   T6 5625NNNO37   1    1     1    1     1     1    1    10   1    1  116   19   19  29   29   29  Probe   2          T4     5 5625NNNO39   1    10   1    1    1    1    10  19
129. rection   Refrigerant flow direction    5 5 REFRIGERATION COMPRESSOR    The compressor is the pump of the system where the refrigerant coming from the evaporator  low pressure  side  is compressed up to the condensation pressure  high pressure side     All the compressor used are manufactured by primary companies and are designed for applications where  high compression ratios and wide temperature changes are present    The fully sealed construction is perfectly gas tight  so ensuring high energy efficiency and long useful life   The pumping unit is supported by dumping springs  in order to consistently reduce the acoustic emission  and the vibration diffusion    The electric motor is cooled down by the aspirated refrigerant gas  which goes through the coils before  reaching the compression cylinders  The internal type thermal protection protects the compressor from  overloads  The protection is automatically restored as soon as the nominal temperature conditions are  reached     5 6 CONDENSER  AirCooled     The condenser is the element in which the refrigerant gas coming from the compressor is cooled and  condensed into a liquid  Mechanically  the condenser is a copper tube coil with aluminum fins to improve  heat transfer  Cooling air flow is provided by high efficiency multi blade axial fan s     The coil and fan assembly are contained in a robust  pressed steel enclosure    For correct operation of the condenser the temperature of the ambient air should not exceed the nom
130. rotection Vent    refroidissement    air    le dispositif de protection   lectrique   voir Q2 sur sch  ma   lectrique  du ventilateur s est d  clench     le r  armer et  v  rifier le bon fonctionnement du s  cheur ou bien est intervenu le dispositif de  protection  voir TV sur sch  ma   lectrique     l int  rieur du ventilateur   attendre  30 minutes et retenter    3   STOP Compr  LP    Le pressostat PB s est d  clench     voir paragraphe sur ce sujet    4     STOP Compr  HP    Le pressostat PA s est d  clench     voir paragraphe sur ce sujet    5     Condens  HAUT      la temp  rature de condensation est trop haute   voir  paragraphe sur ce sujet    6     PointRose BAS      le PointRose est trop Bas   voir paragraphe sur ce sujet    7     PointRose HAUT      le PointRose est trop Haut   voir paragr  sur ce sujet    8     Sonde FAULT      une des sondes est d  fectueuse   voir paragraphe sur ce sujet                     pressostat de basse  gt       a une fuite de gaz                    contacter un technicien frigoriste   pression PB s est d  clench  e    Le r  amor  age du pressostat s effectue automatiquement d  s que les conditions    nominales se r  tablissent   v  rifier le bon fonctionnement du s  cheur         Le pressostat de haute pression  gt  D  celer la cause    l origine du d  clenchement du pressostat parmi les suivantes      PA s est d  clench  e      DMC20  La temp  rature de  condensation est trop   lev  e         PointRose trop Haut     1  La temp  rature a
131. rrupteur  de commande  le message  Attente Commande Remote  s affiche    l   cran et il est possible de  commander    partir du pupitre en facade du DMC20 certaines fonctions du s  cheur  Lorsque le contact est  r  ouvert  le s  cheur retourne    l   tat initial de d  part  Attente Commande s il   tait en Attente Commande et  allum   s il   tait allum        i S   IL EST UTILISE  LE CONTROLE A DISTANCE A LA PRIORITE SUR LES COMMANDES EN FACADE DU    N CPM lt     Z       DMC20  L   UTILISATEUR ASSUME LA RESPONSABILITE DE PRENDRE DES PRECAUTIONS PARTICULIERES  POUR LE POSSIBLE DEMARRAGE A L   IMPROVISTE DU SECHEUR            5 21 5 SIGNALISATION    DISTANCE D   UNE ALARME    Un contact en   change pouvant   tre utilis   pour signaler    distance la somme de n importe quel   tat  d alarme du s  cheur est disponible  voir bornes 18  19 et 20 sur le sch  ma   lectrique      5 21 6 CODE D ACCES  Le code d acc  s au niveau 2 est fourni en m  me temps que ce manuel     Le constructeur d  cline toute responsabilit   en cas de dommages dus    la manipulation des  param  tres de fonctionnement     Le code d acc  s doit   tre conserv   par du personnel comp  tent     5 21 7 COMMUNICATION SERIELLE    Le DMC20 est dot   d un port s  rie RS485  voir bornes A et B    l arri  re du DMC20  qui lui permet de faire  partie d un r  seau  network  g  r   par PC ou PLC de supervision    255 unit  s DMC20 maximum peuvent   tre branch  es au m  me r  seau    Si un PC est utilis    la connexion entre 
132. rs must be performed by qualified personnel only   Before performing any service or maintenance on the equipment the technician must insure  the following     e must take every precaution to insure that no part of the machine being serviced or  maintained has live power to it  The main disconnect on the unit and from the main power  supply must be switched off before performing service  In order to insure safety it is also  recommended that the main power wiring leading to the equipment be disconnected    e must depressurize the equipment in order to insure a safe working environment  It is also  recommended that a by pass be used in order to isolate the unit under service and prevent any  unwanted pressurizing to occur during service and maintenance  If required the unit may also be  disconnected at the air inlet and outlet to insure safety     Before attempting any maintenance operation on the dryer  switch it off and wait at least 30  minutes  During operation the copper piping connecting the compressor to the condenser can reach  dangerous temperature able to burn the skin     DAILY   e Make sure that the temperatures displayed by the electronic device complies with the plate data   e Check the proper operation of the condensate drain systems    e Verify the condenser for cleanliness  AirCooled      EVERY 200 HOURS OR MONTHLY   e With an air jet  Max  29 psig  2 barg  blowing from inside towards outside clean the condenser   repeat this operation blowing from outside towa
133. s connected to a data  transmission network via a serial port     SET UP PARAMETERS TABLE    Parameter Description Adjustment Range    Std  Value    Password to access level 2 0   255           Language Selection of the language for dialogue and alarm Italian   English  messages German   French      DewPoint Set                   temperature of the hot gas solenoid valve   Min   Max DewPoint    1 0   C    E Drain Pause  Pause between two Evaporator discharges    0 5 10      4 0           Max DewPoint                  value for the DewPoint setting range Min DewPoint    19 9   C    Low   DewPoint    Temperature of interv  for the too low DewPoint alarm  10 0   0 0   C  Low DP   Diff   Differential temperature for the too low DewPoint alarm 1 0   10 0   K  Low       Delay Delay time for the too low DewPoint alarm 0 5   20 min    Low DP   Stop   STOP enabled in case the DewPoint of the dryer is too low YES NO  High DewPoint     Temperature of interv  for the too high DewPoint alarm 10 0   20 0   C  High DP   Diff    Differential temperature for the too high DewPoint alarm  1 0    10 0   K  High DP   Delay   Delay time for the too high DewPoint alarm 0 5   30 min  High DP   Stop   STOP enabled in case the DewPoint of the dryer is too high YES NO    Condensation     Temp  of intervention for the too high condensation 50 0   70 0   C 60 0   C  temperature alarm   Condens   Diff   Differential temp  for the too high condensation  1 0    10 0   K  5   K  temperature alarm    Condens 
134. s contr  les doivent   tre effectu  s par du personnel qualifi          Faire tr  s attention s il s av  re n  cessaire d intervenir sur le circuit frigorifique  Le r  frig  rant sous    DEFAUT CONSTATE        Le s  cheur ne d  marre pas            compresseur ne marche  pas        Le s  ventilateur s  ne marche pas   refroidissement    air         ADS93  Le t  moin de pr  sence  d alarme est allum          DMC20  Le t  moin    alarme en  cours  est allum       CAUSE PROBABLE   INTERVENTION SUGGEREE     gt  V  rifier que l alimentation   lectrique est bien pr  sente      gt  ADS93  Le t  moin de pr  sence d alarme est allum     voir paragraphe sur ce sujet      gt  DMC20  Le t  moin  alarme en cours    est allum     voir paragraphe sur ce sujet    c   Le dispositif de protection   lectrique s est d  clench    voir Q3   Q4 sur  le sch  ma   lectrique  du circuit des dispositifs auxiliaires   le r  amorcer  et v  rifier le bon fonctionnement du s  cheur    c   V  rifier les c  bles   lectriques     c   ADS93  Le t  moin de pr  sence d alarme est allum     voir paragraphe sur ce sujet      gt  DMC20  Le t  moin  alarme en cours    est allum     voir paragraphe sur ce sujet      gt  Le dispositif de protection    l int  rieur du compresseur s est d  clench      attendre 30 minutes et retenter     gt  V  rifier les c  bles   lectriques    c   Le t  l  rupteur de commande du compresseur  voir K sur sch  ma    lectrique  est d  fectueuse   le remplacer     gt  Si le d  faut persiste
135. stobpbd     Air Cooled  protection of the fan    Refrigerant low pressure R404A   1 0 barg    STOP Compr  LP switch  PB  R404A   14 5 psig No delay The dryer is stopped    a  SC    Probe        One of the probes is faulty        Nodelay          dryer does not stop      ALARMS MEMORY    When the    Start at Power Up    and    Recovery After      functions are deactivated  Note  this is the  standard factory setting  set at             any alarm causing the dryer to stop and any anomaly with one or  more probes  Probe Fault  is stored in the memory of DMC20  To reset the alarm memory the dryer is to be  switched OFF  keep the button  15   Dryer Stop  pressed for at least 2 seconds   The dryer is then to be  switched ON again  keep the button  14   Dryer Start up  pressed for at least 2 seconds   If the alarm is no  longer in effect the dryer will run correctly  otherwise the alarm message will appear again    When    Start at Power Up    and    Recovery After      functions are activated  customer selected setting     yes     any alarm which has caused the stop of the dryer and any anomaly with one or more probes  Probe  Fault  is automatically reset once nominal conditions return and the dryer will run again automatically    Any alarm  which is not causing the stop of the dryer  is reset automatically when nominal working  conditions return        5 21 3 SET UP    The DMC20 is adjusted during the final test of the dryer  Where particular requirements concerning the operation 
136. sur la plaque du s  cheur    e V  rifier que le sens de rotation du ventilateur est  conforme au sens des fl  ches adh  sives coll  es  sur le condensateur  refroidissement    air     e Attendre quelques minutes que le s  cheur  atteigne la temp  rature n  cessaire    e Ouvrir lentement le clapet d entr  e de l air    e Ouvrir lentement le clapet de sortie de l air    e Si le syst  me by pass est install    fermer  lentement le clapet central    e V  rifier qu il n y a pas de fuites d air dans les  conduites     DMC20 Air Dryer Controller    e V  rifier que tous les points du chapitre   Installation  sont respect  s    e V  rifier que les raccordements air comprim      la  machine sont bien serr  s et que les conduites sont  bien fix  es    e V  rifier que les dispositifs d   vacuation du le  condensat sont bien fix  s et raccord  s    un  r  cipient ou    une installation de collecte    e V  rifier que le syst  me by pass  si install    est ferm     e V  rifier que les clapets manuels situ  s sur les  circuits d   vacuation du le condensat sont ouverts    e Eliminer tous les emballages et tout ce qui peut  entraver dans la zone du s  cheur    e Activer l interrupteur g  n  ral d alimentation    e Activer le sectionneur g  n  ral   rep  2 du pupitre  de commande    e V  rifier que les t  moins  r  sistance huile carter   et  s  cheur en Attente Commande  du DMC20  sont allum  s    e Attendre au moins deux heures avant de faire  d  marrer le s  cheur  la r  sistance carter doi
137. t  chauffer l huile du compresseur     e V  rifier que le d  bit d eau de refroidissement est  pr  sent  refroidissement    eau     e Appuyer sur la touche  marche s  cheur  du  DMC20 pendant deux secondes minimum    e V  rifier que le t  moin    compresseur en marche   du DMC20 est allum      e Attendre quelques minutes  v  rifier que  l instrument  DMC20 indique la bonne  temp  rature de service et que le condensat est  r  guli  rement   vacu      e V  rifier que l absorption   lectrique est conforme  aux donn  es figurant sur la plaque du s  cheur    e V  rifier que le sens de rotation du ventilateur est  conforme au sens des fl  ches adh  sives coll  es  sur le condensateur  refroidissement    air     e V  rifier le bon fonctionnement des circuits  d   vacuation du le condensat   attendre les  premi  res interventions    e Attendre quelques minutes que le s  cheur  atteigne la temp  rature n  cessaire    e Ouvrir lentement le clapet d entr  e de l air    e Ouvrir lentement le clapet de sortie de l air    eSi le syst  me by pass est install    fermer  lentement le clapet central    e V  rifier qu il n y a pas de fuites d air dans les  conduites           3 3 MARCHE ET ARRET    REMARQUE   Lors de p  riodes d inactivit   n   tant pas excessives  2 3 jours maximums   il est conseill   de  laisser le s  cheur aliment   et le sectionneur g  n  ral   rep  2 du pupitre de commande    activ    Dans le cas contraire  il est indispensable d attendre deux heures au moins avant de  fa
138. t  ral   Pupitre de commande   Tuyau en cuivre porte sonde  Point de ros  e     T1   Transformateur TF 575 460    ATTACHMENTS    ANLAGEN s    8 2 TDF 145 340                     Gi             NE           8                                         N                                            zl  l     e   ND                      8 3 TDF 420 680                         8 4 TDF 145 340 WC        amp                  W                     NE H  Heft LT                          8    t gt  e e i                      5                             MN    G          N                            A                     2               8 5 TDF 420 680 WC       The access code to the 2 level is      20          Le code d acc  s au niveau 2 est     
139. t essentiellement deux   l air entrant est  d  j   partiellement refroidi et l installation frigorifique pourra donc   tre dimensionn  e de facon    garantir une  chute thermique plus limit  e permettant de r  aliser des   conomies d   nergie  40 5096   en second lieu  de  l air froid n est pas introduit dans la ligne d air comprim    ce qui pr  vient avant toute la formation de  condensation sur la surface ext  rieure des tuyaux de ligne           5 17 SEPARATEUR DE CONDENSAT           froid sortant de l   vaporateur est achemin      l int  rieur d   un s  parateur du le condensat     demister  qui  est form   de grillage d   acier inoxydable  Le condensat transport   de l air quand arrive au contact de la  grillage m  tallique est s  par   et expuls   du dispositif de purge  L air ainsi trait    froid et sec  est achemin    vers la sortie pour acc  der    l   changeur                Ce type de s  parateur du le condensat     demister  offre  l avantage d obtenir une efficacit     lev  e lors de variation du d  bit d air  on outre les op  rations d entretien  ne doivent pas   tre effectu  es     5 18 PRESSOSTAT GAZ FRIGORIGENE P    Pg   Py    Une s  rie de pressostats a   t   install  e sur le circuit du gaz cryog  ne pour assurer la s  curit   d exploitation  et le maintien du s  cheur en bon   tat     PB  Pressostat de basse pression plac  e du c  t   aspiration  carter  du compresseur   il intervient si la  pression descend au dessous de celle r  gl  e  Le                
140. tPoint  2   2    4  C  36   4    40  F   To modify the Set Point  within the limits 5L and Gh set  while programming   hold down the key       and change the value with the keys and     e Condensate drain solenoid valve  It remains on for a period equal to dr  3 seconds  with a 60 seconds  pause  To change the pause time between two successive drainage  within the limits rL and rh set    while programming  hold down the key and modify the value with the keys and      SET UP  PROGRAMMING   At the start up  the dryer displays the current dew point temperature     Pressing the key the condensation temperature will be visualized   Holding down simultaneously the keys and for at leas 5 seconds the programming is initiated  and on the display will appear  L      To select the desired parameter  press sequentially the key         To change the value of the selected parameter  use the keys and Fa   All the parameters can be modified referring the following table     Range value      Minimum tit of the SetPont        9 30   o ron    5h  Max limit ofthe SetPoint       05                   Differential value ofthe             1 7      rcer   1  Minimum limit for the condensate drain pause   01299   06   6055      Eh  Max mit forthe condensate drain pause   1 9   18   18060    dr  Duration ofthe condensate damage al 30   3se     Fs                         Fd                                 _   xi                     _   uS  ons                       To exit the programming mode  press an
141. ta are exchanged in  ASCII mode with the following format      Baud rate   9600 Data bit   7 Stop bit   1 Parity   even    DATABASE  Here below are listed parameter description  type and address of dates on DMC20      Description Type    DewPoint Signed Integer  Air  gt O  Air    O  Compr LP  Compr HP  Condens   Water    O  Ambient  Language  DewPoint Set  DewPoint Diff   E Drain Time  E Drain Pause  S Drain Time  S Drain Pause  Display Contrast  Min DewPoint  Max DewPoint  Low DewPoint    Low DP   Diff   Low DP   Delay  High DewPoint    High DP   Diff   High DP   Delay  Condensation    Condens   Diff   Condens   Delay  Peripheral No   Working  Alarm STOP  Alarm Status  Cond  Fan Switch    Remote ON OFF  Switch    DewPoint LOW  DewPoint HIGH    DewPoint temperature   T1 probe  emperature of the incoming air   T2 probe Signed Integer  emperature of the outgoing air   T3 probe Signed Integer  uction temperature of the compressor  low pressure side    T4 probe     Signed Integer   high pressure side    T5 probe Signed Integer   Condensing temperature   T6 probe Signed Integer  nlet temperature of the cooling water  Water Cooled    T8 probe     Signed Integer  Ambient temperature   T7 probe Signed Integer  election of the language for dialogue and alarm messages Signed Integer  Activation temp  of the hot gas by pass solenoid valve Signed Integer  pass solenoid valve Signed Integer   Signed Integer  Signed Integer    O    vaporator discharge time  ause between two Evaporator disc
142. te de laisser 40 in   1 m  minimum  de chaque c  t   du s  cheur afin de faciliter la EE  es  ventilation et toute   ventuelle op  ration min  1 m    d entretien     Le s  cheur n a pas besoin de fixation au plan  d appui              2 3 SCHEMA D INSTALLATION       Compresseur d air       R  frig  rant final                                                                S  parateur de       condensation  Pre   Filtre    Bac air comprim               Filtre final  S  cheur  Groupe by pass       Purgeur de       condensation                Il est conseill   d utiliser l installation du type A lorsque les compresseurs marchent par intermittence r  duite  tandis que la somme des consommations   quivaut au d  bit du compresseur     Il est conseill   d utiliser l installation du type B lorsque les consommations d air sont tr  s variables et les  valeurs instantan  es sont sup  rieures au d  bit des compresseurs  Le bac doit avoir une capacit   suffisante     satisfaire avec l air emmagasin   les demandes de courte dur  e et valeur   lev  e  impulsives               2 4 FACTEURS DE CORRECTION    Facteur de correction selon la variation de la pression de service     Pression air entr  e psig   60   70   85   100   115   130   140   155   174          bag  41   48   59   69   79   90   9 7   107   120    Temp  rature ambiante   F       80   9          0   13    Facteur  F2    109   1 06   100   090   083      Facteur de correction selon la variation de la temp  rature air entr  e    
143. tendre quelques minutes  v  rifier que  l instrument DMC20 indique la bonne  temp  rature de service et que le condensat est  r  guli  rement   vacu      e Alimenter le compresseur d air     e La fonction anti gel est garantie par l intervention  de l   lectrovanne de by pass gaz chaud signal  e  par le t  moin lumineux sp  cial se trouvant sur  l instrument DMC20        Arr  t  voir paragraphe 5 1 Pupitre de Commande      ADS93 Controller   e V  rifier que la temp  rature indiqu  e par  l instrument ADS93 est correcte    e Eteindre le compresseur d aria    e Apr  s quelques minutes  appuyer sur la touche   ON   OFF    bouton lumineux ON OFF   rep  re  1 du pupitre de commande     DMC20 Air Dryer Controller   e V  rifier que la temp  rature indiqu  e         l instrument DMC20 est correcte    e Eteindre le compresseur d aria    e Apr  s quelques minutes  appuyer pendant 2  secondes minimum sur la touche  arr  t s  cheur   sur le DMC20     REMARQUE  L affichage de la temp  rature comprise entre 32  F et 50  F  0  C et  10  C  est jug  e  correcte compte tenu des conditions de travail possibles  d  bit  temp  rature de l air    en entr  e  temp  rature ambiante  etc       Pendant le fonctionnement  le compresseur frigorifique est toujours en marche   Le s  cheur doit rester allum   pendant toute la dur  e d utilisation de l air comprim   m  me si le compresseur    d air a un fonctionnement discontinu     4 1 CARACTERISTIQUES TECHNIQUES S  CHEURS SERIES TDF145 et TDF185    23 5 
144. teur de la prolongation de la sonde en panne est  correctement introduit dans le DMC20     gt  V  rifier le branchement de la prolongation de la sonde entre le DMC20  et la plaque    bornes     gt  V  rifier le branchement   lectrique de la sonde sur la plaque    bornes     gt  Si le d  faut persiste  remplacer la prolongation et ou la sonde d  fectueuse     REMARQUE  Si la sonde d  fectueuse est T1  PointRose   l     lectrovanne  by pass gaz chaud reste actif tandis que les autres  fonctions du s  cheur ne sont pas influenc  es  en cas de  panne d   une autre sonde  le s  cheur continuera de  fonctionner normalement m  me si en   tat d   alarme     7 2 DEMOLITION DU S  CHEUR    Si le s  cheur doit   tre d  moli  il faut le s  parer par groupes de pi  ces r  alis  es dans le m  me mat  riau        Partie    Mat  riel       Fluide r  frig  rant    R404A           Huile       Panneau en support    Acier    Carbone  peinture   poxy       Compresseur frigorifique    Acier  Cuivre  Aluminium  Huile       Echangeur de chaleur  S  parateur de condensat    Cuivre  Acier       X    s             Condenseur Aluminium  Cuivre  Acier    Carbone  Tuyau Cuivre   Ventilateur Aluminium  Cuivre  Acier   Vanne Bronze  Acier       Mat  riel isolant    Caoutchouc synth  tique sans CFC       C  ble   lectrique    Cuivre  PVC       Parties   lectriques       PVC  Cuivre  Bronze             99    II est conseill   d observer les normes de s  curit   en vigueur pour la d  molition de chaque type de 
145. trique               31          8 LVSNAGNOO NOILVNOWAA ANNWAOYLOA 13                                   LVSN3QNOO NOILVNOVAA 3NNVAOHLO3 T3                      ZV9 SSVd Ad                  2313                    SAONVSSINd JINGOW                             d3SVHOI4AJ4V                           V LHOd                               Sla  Ede a  NI 245  3GN3931           131000       Ad ZHO9 ASZS E  NVA                      AlddNS    3 IL IS iH                     I 1          1       1 G  6  L           9 pl                235   I   2  09      9  9 9  dL       FIELD  INSTALLATION    INSTALLATION      ma    Voir sch    REMARQUE    5 25 2 SCHEMA   LECTRIQUE   AUXILIAIRE 1   TDF145   TDF340   DMC20 AIR DRYER CONTROLLER     IWNOILdO  Lu           Q31000                 Q31000                     b DE                                          ags ape           Kg EUR FT HET      Patt               NOn  BE buli                         AL  d           b              Eod 4    A e       Ek e         f  d  w    s sim  02  6l d        20  90  Tm           FEU 1 1   oz  a 8 5           N  5      9              D XD                 EE          uwa ka abu ay E               1 I         REE BBBBBBBB     I I  I I       a nt le  a E ENEE H             aHa              Kr ZE E A lw 7Y YY  1 I I I I 1 1       I I I I I 1                      RH                        931009             J           NI 81 ANIOd M3Q  LL  AN3lgAV LL        SNISN3QNOO 91              1                          91    
146. ues  Les conduites de raccordement  de type flexible de pr  f  rence   doivent avoir un diam  tre ad  quat par rapport au d  bit n  cessaire et   tre exemptes de rouilles  d   barbures  ou de toute autre salet             2 8 BRANCHEMENT A L INSTALLATION ELECTRIQUE    Le branchement au r  seau d alimentation   lectrique et les syst  mes de protection doivent   tre  conformes aux l  gislations en vigueur dans le pays d utilisation et r  alis  s par du personnel qualifi       Avant d effectuer le branchement  s assurer que la tension et la fr  quence disponibles dans l installation  d alimentation   lectrique correspondent aux param  tres figurant sur la plaque du s  cheur  Une tol  rance de   5  par rapport    la tension indiqu  e sur la plaque est admise    Lors de la livraison le s  cheur est pr  t pour   tre raccord   au secteur par l interm  diaire d un boitier    lectrique    Installer une prise d alimentation dot  e d un interrupteur de secteur diff  rentiel  IAn 0 03A  et  magn  tothermique         de fa  on ad  quate par rapport    l absorption du s  cheur  se reporter aux  param  tres figurant sur le s  cheur     Les c  bles d alimentation doivent avoir une section ad  quate par rapport    l absorption du s  cheur  tenant  compte de la temp  rature ambiante  des conditions de pose  de leur longueur et conform  ment aux normes  de r  f  rence de l Organisme Energ  tique Nationale          est indispensable de garantir le branchement    l installation de dispersion    t
147. ur transmettre le signal    l   lectronique contr  ler et  avec un petit  retard  l   lectrovanne    diaphragme s ouvrira pour purger le condensat  Pour un complet op  ration de purge le  temps d ouverture de vanne est r  gul   exactement pour chaque op  ration  Lors l op  ration de purge est termin  e la  ligne de d  charge est   clus   sans aucune fuite d air comprim      Aucune filtre pour le condensat est install    Aucune r  gulation n est demande    La vanne de service est install  e apr  s le purgeur pour faciliter la recherche d avaries et les   ventuels contr  les       S  CHEUR ACTIV  E V  RIFIER QUE CETTE VANNE A OUVERT     PUPITRE DE COMMANDE    Le pupitre de commande illustr   ci dessous vous permit de contr  ler le  fonctionnement du purgeur      Puissance   LED  t  moin    le purgeur est allum     aliment     Vanne   LED  t  moin    la membrane de l   lectrovanne a ouvert   purge   Power O 7 Alarme   LED  t  moin  clignotant   le purgeur est dans la condition de pr  sence d alarme  Test   touche pour le test de purge    RECHERCHE DES AVARIES    La recherche d avaries et les   ventuels contr  les doivent   tre effectu  s par du personnel qualifi      N Avant toute op  ration  s assurer      Alam    5   Valve OM             e qu aucune pi  ce de la machine ne soit sous tension et que la machine ne puisse  pas   tre rebranch  e au r  seau d alimentation   lectrique   e qu aucune pi  ce de la machine ne soit sous pression et que la machine ne puisse  pas   tre rebr
148. ure closure of the cooling  water system during service operations on the dryer     ADJUSTMENT  Me The condenser water regulating valve is adjusted during factory testing to a pre set value that    covers 90  of the applications  However  extreme operating conditions of the dryer may require a  more accurate calibration  During start up  a qualified technician should check the condensing  pressure   temperature and if necessary adjust the valve by using the screws on the valve itself   To increase the condensing temperature  turn the adjusting screws counter clockwise  to lower it  turn the screws clock wise    Adjust the valve in order to guarantee a condensing gauge temperature of 110 113  F  44 45   C      5 9 LIQUID RECEIVER    As the volume of the refrigeration circuit and system components does not allow sufficient condensed  refrigerant liquid to be stored  a liquid receiver is installed between the condenser and the evaporator  This  makes available a reserve volume of refrigerant liquid able to handle sudden increases in thermal load on  the evaporator     5 10 DEHYDRATION FILTER    The function of the dehydration filter  located before the thermostatic expansion valve  is to remove  impurities and moisture from the refrigerant stream  so avoiding their circulation within the system     5 11 LIQUID SIGHT GLASS    It is installed in the refrigerant piping system and it is used to check for the presence of moisture  It is fitted  with a special chemical substance that 
149. ut only by refrigeration   engineers according to local rules  R404A may be dangerous for men only if it is present in bulk   concentrations  In case of leaks the room is to be aired before any intervention    Any change to the machine or to the relevant operating parameters  if not previously verified and   authorized by the Manufacturer  in addition to create the possibility of dangerous conditions it will   void the warranty    Don t use water to extinguish fire on the dryer on in the surrounding area      P P  gt  pP    1 3 PROPER USE OF THE DRYER    This dryer has been designed  manufactured and tested only to be used to separate the humidity normally  contained in compressed air  Any other use has to be considered improper    The Manufacturer will not be responsible for any problem arising from improper use  the user will be in any  case responsible for any resulting damage    Moreover  the correct use requires the respect of the installation conditions  in particular     e Voltage and frequency of the mains    e Pressure  temperature and flow rate of the incoming air    e Pressure  temperature and cooling water capacity  water cooling system     e Ambient temperature    This dryer is supplied tested and fully assembled  The only operation left to the user is the connection to the  plant in compliance with the instructions given in the following chapters     The purpose of the machine is the separation of water and eventual oil particles present in  compressed air  The 
150. y time the key             In case any entry is made within 10 seconds  the system exits automatically the programming mode     5 21 DMC20 AIR DRYER CONTROLLER       Back lighted LCD display 9  Led alarm ON   Led compressor ON 10  Condensate drain test button  Led condenser fan s  ON 11  Set up access button   Led hot gas by pass solenoid valve ON 12  Incremental button    Led evaporator condensate drain solenoid valve      13  Decrement button  Led condensate separator drain solenoid valve ON 14  Dryer start up button  Led crankcase heater ON 15  Dryer stop button   8  Led dryer in Stand by    Oe OP 09      m    The DMC20 controls all the operations  the alarms and the operational setting of the dryer  By means of a  32 characters display it shows all the operating conditions  In case of abnormalities  a set of messages in  the selected language allows a fast detection of the fault and the relevant solution    5 21 1 DISPLAY MESSAGES    When the main switch is turned ON  all the characters of the DMC20 display are activated for 2 seconds     Afterwards  appears the software release  and finally the two lines of the display are ready for their normal  functions     When the dryer is in stand by condition  the display shows  Stand by   and the  crankcase heater  and   Stand by  leds are ON  If the remote command is in use  the display shows  Stand by Remote     To switch ON the dryer  keep the button  14   Dryer Start up  pressed for at least 2 seconds  NOTE   DMC20 has an int
    