1. Notas Coloque la pinza alrededor de un solo conductor nicamente Cierre completamente la pinza a fin de asegurar una medici n exacta Para obtener una mayor precisi n centre el cable en la pinza CM 700 CM 750 Nota En el caso de mediciones de corriente continua la corriente que fluya a trav s de la pinza en la direcci n indicada por la flecha arrojar una lectura positiva Para mayor precisi n oriente la pinza hacia la lectura positiva 25 GREENLEE Mediciones mas comunes Medici n de corriente Con la pinza colocada alrededor del separador de l neas Notas El separador de l neas Greenlee 93 30 est dividido Una secci n lee amperios la otra amperios multiplicados por 10 Cierre completamente la pinza a fin de asegurar una medici n exacta Para obtener una mayor precisi n centre el separador de l neas en la pinza Medici n de resistencia 26 CM 700 CM 750 Precision Consulte la secci n Especificaciones en relaci n con las condiciones de operaci n y el coeficiente de temperatura La precisi n se especifica de la siguiente manera un porcentaje de la lectura una cantidad fija a e 18 C a 28 C 64 F a 82 F para mediciones de tensi n y resistencia e 21 C a 26 C 70 F a 79 F para mediciones de corriente 0 a 80 de humedad relativa Corriente alterna 21 C a 26 C para el m
2. Remarque Avant de renvoyer un appareil de mesure v rifiez la pile et assurez vous qu elle est charg e au complet For technical assistance 800 435 0786 GREENLEE ARCI Greenlee Textron Subsidiary of Textron Inc 4455 Boeing Drive Rockford IL 61109 2988 USA Technical Customer Service International 815 397 7070 Fax 815 397 9247 Customer Service North America 800 435 0786 Fax 800 451 2632 815 397 1865 Canada Fax 800 524 2853
3. Risques de d charge lectrique Un contact avec des circuits sous tension peut entra ner des blessures graves voire mortelles 1 R gler le s lecteur partir du Tableau des r glages 2 Se reporter aux mesures types pour obtenir des instructions de mesure sp cifiques 3 V rifier l appareil sur un circuit ou sur un composant connu Sil appareil ne fonctionne pas comme pr vu sur un circuit dont le fonctionnement est connu remplacer la pile Sil appareil ne fonctionne toujours pas comme pr vu le renvoyer Greenlee pour qu il soit r par Voir l adresse indiqu e sous la garantie 4 Lirele circuit ou le composant v rifier 5 Sila lecture est en c c enlever la pince du circuit et appuyer sur le bouton ZERO A O 1 Serrer encore la pince autour du circuit pour mesurer le courant c c actuel Tableau des r glages Pour mesurer cette valeur Continuit r gler le s lecteur ce symbole Q et appuyer sur ZERO A 0 connecter le fil rouge V Q et connecter le filnoira COM R sistance Q x V Q COM Tension c c V V Q COM Tension c a Ve V Q COM Courant c c 600 A max A Enlever le fil Enlever le fil Courant c a 600 A max A Enlever le fil Enlever le fil Des tonalit s sont mises si la r sistance mesur e est inf rieure 50 Q et s arr tent si la r sista
4. IEC 1010 1 or IEC 60664 Overvoltage Category Signal level Electronic and telecommunication equipment or parts thereof Some examples include transient protected electronic circuits inside photocopiers and modems Overvoltage Category Il Local level Appliances portable equipment and the circuits they are plugged into Some examples include light fixtures televisions and long branch circuits Overvoltage Category Ill Distribution level Permanently installed machines and the circuits they are hard wired to Some examples include conveyor systems and the main circuit breaker panels of a building s electrical system Overvoltage Category IV Primary supply level Overhead lines and other cable systems Some examples include cables meters transformers and other exterior equipment owned by the power utility 15 GREENLEE Maintenance ACAUTION Do not attempt to repair this unit It contains no user serviceable parts Do not expose the unit to extremes in temperature or high humidity See Specifications Failure to observe these precautions can result in injury and can damage the unit Battery Replacement AWARNING Before opening the case remove the test leads from the circuit and shut off the unit Failure to observe this warning can result in severe injury or death Disconnect the unit from the circuit Remove the screw from the battery door Remove the battery door Replace the battery obse
5. n sobre Seguridad A ADVERTENCIA Peligro de electrocuci n El contacto con circuitos activados puede ocasionar graves lesiones o incluso la muerte ADVERTENCIA Peligro de electrocuci n e incendio No exponga esta unidad ni a la lluvia ni a la humedad No utilice esta unidad si se encuentra mojada o da ada Utilice cables de prueba y accesorios que sean apropiados para la aplicaci n que se va a realizar Consulte la informaci n sobre categor a y voltaje nominal del cable de prueba o el accesorio Revise minuciosamente los cables de prueba o el accesorio antes de utilizarlos Deber n estar limpios y secos y su forro aislante deber hallarse en buenas condiciones Utilicela nicamente para el prop sito para el que ha sido dise ada por el fabricante tal como se describe en este manual Cualquier otro uso puede menoscabar la protecci n proporcionada por la unidad De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte A ADVERTENCIA Peligro de electrocuci n No aplique m s del voltaje nominal entre dos terminales de entrada cualesquiera o entre una terminal de entrada cualquiera y una conexi n a tierra No toque las puntas de los cables de prueba ni ninguna parte del accesorio que carezca de forro aislante De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte 19 GREENLEE Importante Informaci n sobre Segurida
6. 40 0 200 0 15 0 7A 200 0 400 0 400 600 Courant c c 18 a 28 C 400 0 mV 0 7 0 2 mV 4 000 V 0 7 0 002 V 40 00 V 0 7 0 02 V 400 0 V 0 7 0 2 V 600 V 0 7 2 V R sistance 18 28 C 400 0 Q 1 2 0 6 Q 4 000 ka 0 9 0 003 kQ 40 00 ka 0 9 0 03 kQ 400 0 ka 1 2 0 3 kQ 4 000 MQ 1 2 0 003 MQ 40 00 MQ 2 5 0 05 MQ f La lecture peut avoir oscill jusqu a 6 chiffres a proximit de la pleine chelle La lecture peut avoir oscill jusqu 3 chiffres proximit de la pleine chelle Temps de r ponse d environ 20 secondes Maintien maximum La pr cision des valeurs maintenues est indiqu e dans le tableau 10 chiffres par changement de plage Par exemple une pointe de 100 V c c sur un signal de 200 mV c c exige 3 tapes de plage pour la mesure L ajout la sp cification de pr cision est de 3 x 10 chiffres sur la plage de 400 0 volts ou 3 0 volts Remarque La pr cision de maintien maximum pour la r sistance est sp cifi e uniquement pour les plages allant de 400 0 Q 400 0 kQ 44 CM 700 CM 750 Sp cifications Affichage 3 3 4 chiffres sur cran cristaux liquides compte maximum de 3 999 Taux d chantillonnage 2 par seconde Ouverture de la pince 35 mm 1 38 po Cat gories de protection contre la surtension Cat gorie
7. 9 10 A Tensi n continua 18 C a 28 C 400 0 mV 0 796 0 2 mV 4 000V 0 7 0 002V 40 00V 0 796 0 02V 400 0V 0 796 0 2V 600V 0 796 2V Resistencia 18 C a 28 C 400 0 Q 1 2 0 6 Q 4 000 ka 0 9 0 003 kQ 40 00 kQ 0 9 0 03 kQ 400 0 ka 1 2 0 3 kQ 4 000 MQ 1 2 0 003 MQ 40 00 MQ 2 5 0 05 MQ f La lectura podria mostrar una fluctuaci n de hasta 6 d gitos a casi plena escala La lectura podr a mostrar una fluctuaci n de hasta 3 d gitos a casi plena escala TEI tiempo de respuesta es de aproximadamente 20 segundos Valor M ximo La precisi n del valor retenido es la precisi n establecida en la tabla 10 d gitos para cambio de gama Por ejemplo un pico de 100V CC en una sefial de 200 mV CC requiere 3 pasos de gama para medir La suma de la especificaci n de precisi n es 3 x 10 d gitos en la gama de 400 0 voltios o 3 0 voltios Aviso La precisi n del valor m ximo para resistencia se especifica nicamente en gamas de 400 0 Q a 400 0 kQ 28 CM 700 CM 750 Especificaciones Pantalla Pantalla de cristal liquido LCD de 3 3 4 digitos resoluci n m xima de 3999 puntos Frecuencia de muestreo 2 por segundo M xima abertura de la pinza 35 mm 1 38 pulg Categor a de protecci n de sobretensi n Categoria IIl 600V Coeficiente de temperatura 0 2 x Precisi n por C mayor o meno
8. li es l utilisation de cet outil Suivre toutes les consignes de s curit indiqu es Dessein Ce manuel d instructions est concu pour que le personnel puisse se familiariser avec les m thodes d utilisation et d entretien s res des multim tres num riques pinces CM 700 et CM 750 de Greenlee Mettre ce manuel la disposition de tous les employ s On peut obtenir des exemplaires gratuits sur simple demande Greenlee et sont des marques d pos es de Greenlee Textron CONSERVER CE MANUEL 33 GREENLEE Consignes de s curit importantes 34 SYMBOLE D AVERTISSEMENT Ce symbole met en garde contre les risques et les manipulations dangereuses pouvant entrainer des blessures ou l endommagement du mat riel Le mot indicateur d fini ci dessous indique la gravit du danger Le message qui suit le mot indicateur indique comment emp cher le danger A DANGER Danger imm diat qui s il n est pas pris en consid ration ENTRAINERA des blessures graves voire mortelles AVERTISSEMENT Danger qui s il n est pas pris en consid ration POURRAIT entrainer des blessures graves voire mortelles A ATTENTION Dangers ou manipulations dangereuses qui s ils ne sont pas pris en consid ration POURRAIENT EVENTUELLEMENT entra ner des dommages la propri t ou causer des blessures AVERTISSEMENT Lire attentivement et bien comprendre cette documentation avant d utiliser ou de
9. local Aparatos el ctricos equipo port til y los circuitos a los que est n conectados Como ejemplo pueden citarse dispositivos de iluminaci n televisores y circuitos de rama larga Categoria de sobretensi n Ill Nivel de distribuci n M quinas instaladas permanentemente y los circuitos a los que est n cableados Como ejemplo pueden citarse sistemas conductores y los paneles del interruptor autom tico principal del sistema el ctrico de un edificio Categor a de sobretensi n IV Nivel de abastecimiento primario L neas a reas y otros sistemas de cable Como ejemplo pueden citarse cables medidores transformadores y cualquier otro equipo exterior perteneciente a la empresa de servicio el ctrico 30 CM 700 CM 750 Mantenimiento APRECAUCION No intente reparar esta unidad ya que contiene partes que deben recibir mantenimiento por parte de un profesional e No exponga la unidad a ambientes de temperatura extrema o altos niveles de humedad Consulte las Especificaciones De no observarse estas precauciones podr an sufrirse lesiones o dafios a la unidad C mo reemplazar la pila ADVERTENCIA Antes de abrir la caja retire del circuito los cables de prueba y apague la unidad De no observarse esta advertencia pueden sufrirse graves lesiones o incluso la muerte Desconecte la unidad del circuito Retire el tornillo de la puerta del compartimiento de las pilas Retire la puerta del compartimi
10. mV Unspecified Unspecified 4 000 V 1 5 0 005 V 40 to 300 Hz 40 00 V 1 5 0 05 V 9 MQ 100 pF 400 0 V 1 5 0 5 V 40 to 500 Hz 600 V 1 5 5 V CM 700 is average sensing RMS calibrated CM 750 is true RMS sensing Accuracy is specified for sine waves at full scale and non sine waves below half scale For non sine waves add the following crest factor corrections Crest factor 1 4 to 2 0 add 1 0 Crest factor 2 0 to 2 5 add 2 5 Crest factor 2 5 to 3 0 add 4 0 12 CM 700 CM 750 Accuracy cont d DC Current 21 C to 26 C 0 0 to 40 0 1 5 1 0A 40 0 to 200 0 1 5 0 7 A 200 0 to 400 0 2 5 0 7 A 400 to 600 1 9 10A DC Voltage 18 C to 28 C 4 000 V 0 7 0 002 V 400 0 V 0 7 0 2 V 600 V 0 7 2 V Resistance 18 C to 28 C 400 02 1 2 0 6 Q 4 000 ka 0 9 0 003 kQ 40 00 ka 0 9 0 03 kQ 400 0 ka 1 2 0 3 kQ 4 000 Ma 1 2 0 003 MQ 40 00 MQ 2 5 0 05 MQ f t Reading may have ripple up to 6 digits near full scale Reading may have ripple up to 3 digits near full scale TResponse time approximately 20 seconds Maximum Hold Accuracy of held value is stated accuracy from table 10 digits per range change For example a 100 VDC spike on a 200 mVDC signal requires 3 range steps to measure The addition to the accuracy specification
11. 50 Identification 1 Pince 2 Levier 3 Borne d entr e commune COM 4 Borne d entr e de volts ou de r sistance V Q 5 Afficheur 6 S lecteur 7 Bouton c c de z ro amp res et avertisseur sonore allum teint 8 Bouton de maintien maximum Ic nes de l afficheur 9 Pile faible ou d charg e 10 Indicateur de polarit 11 DG Courant continu 12 ae Courant alternatif 13 S lection automatique de la plage 14 Fonction de maintien activ e 15 IN Valeur maximum affich e 16 Gy Moyenne quadratique CM 750 uniquement 3 4 17 Indicateur de continuit 18 M M ga 108 13 14 15 16 19 k Kilo 103 eS 12 4 Hea cis 20 Q Ohms em m 21 m Milli 103 Me Ue NI T T 22 V Volts HLILILI s 23 A Amp res 9 EH em aer ee A 24 30 00 Affichage num rique i Symboles apparaissant sur l appareil Avertissement Lire le manuel d instructions al Isolation double p 17 I 18 20 p 21 23 37 GREENLEE Utilisation des fonctions 38 HOLD MAX Appuyer quelques secondes pour maintenir la valeur en cours sur l afficheur Appuyer de nouveau pour revenir au mode normal Pour utiliser la fonction de maintien maximum maintenir le bouton enfonc avant de mettre l appareil sous tension Appuyer de nouveau pour remettre z ro la valeur sauvegard e Maintenir pendant 2 secondes pour revenir l affichage norma
12. Este manual de instrucciones tiene como prop sito familiarizar a todo el personal con los procedimientos de operaci n y mantenimiento seguros para los Medidores digitales con pinza modelos CM 700 y CM 750 de Greenlee Mant ngalo siempre al alcance de todo el personal Puede obtener copias adicionales de manera gratuita previa solicitud Greenlee y son marcas registradas de Greenlee Textron CONSERVE ESTE MANUAL 17 GREENLEE Importante Informaci n sobre Seguridad 18 S MBOLO DE ALERTA SOBRE SEGURIDAD Este s mbolo se utiliza para indicar un riesgo o pr ctica poco segura que podr a ocasionar lesiones o dafios materiales Cada uno de los siguientes t rminos denota la gravedad del riesgo El mensaje que sigue a dichos t rminos le indica c mo puede evitar o prevenir ese riesgo APELIGRO Peligros inmediatos que de no evitarse OCASIONARAN graves lesiones o incluso la muerte A ADVERTENCIA Peligros que de no evitarse PODR AN OCASIONAR graves lesiones o incluso la muerte A PRECAUCI N Peligro o pr cticas peligrosas que de no evitarse PUEDEN OCASIONAR lesiones o da os materiales A ADVERTENCIA Lea y entienda este documento antes de manejar esta herramienta o darle mantenimiento Utilizarla sin comprender c mo manejarla de manera segura podr a ocasionar un accidente y como resultado de ste graves lesiones o incluso la muerte CM 700 CM 750 Importante Informaci
13. I 17 I 18 20 I 21 23 CM 700 CM 750 Using the Features HOLD MAX QJ Press momentarily to hold the present value on the display Press again to return to normal mode To use the Maximum Hold function press and hold before turning the unit on Press again to reset the stored maximum value Press and hold for 2 seconds to return to normal display To remove the Maximum Hold function turn the unit off and then back on ZERO A Q For DC current measurements close the jaw around the conductor Orient the jaw for a positive reading for greatest accuracy Remove the jaw from the conductor and close it Press the ZERO A button This compensates for residual magnetism in the jaw Place the jaw over the conductor keeping the same orientation and take the reading For continuity measurements press to enable tone The icon appears on the display and the meter switches to the 400 Q range Press again to measure resistance Auto Power Off Disable Turn the selector to the OFF position Press and hold the ZERO A Q button while quickly turning the selector to the Q position The unit will now stay on until the selector is set to OFF or until the battery is depleted approximately 150 hours for a fresh alkaline battery The next time the unit is turned on the 30 minute Auto Power Off will be enabled GREENLEE AC Measurement AC measurements are usually displayed as RMS root mean
14. III 600 volts Coefficient de temp rature 0 2 x pr cision par C au dessus ou au dessous de la plage sp cifi e dans la section Pr cision Conditions d utilisation 0 30 C 32 86 F 0 80 d humidit relative sans condensation 30 40 C 86 104 F 0 75 d humidit relative sans condensation 40 50 C 104 122 C 0 45 d humidit relative sans condensation Remarque La mesure en cours est limit e 40 C 104 F Utilisation l int rieur uniquement Conditions d entreposage 20 60 C 4 131 F 0 70 d humidit relative sans condensation Enlever la pile Altitude 2 000 m 6 500 pi maximum Degr de pollution 2 Pile une pile de 9 volts NEDA 1604 JIS 006P ou IEC 6F22 Dur e de vie de la pile approximativement 150 heures avec une pile alcaline 45 GREENLEE Cat gories d installation de surtension Ces d finitions sont d riv es des normes internationales sur la s curit pour la coordination de l isolation telle qu elle s applique la mesure au contr le et l quipement de laboratoire Ces cat gories de surtension sont expliqu es plus en d tail par la Commission lectrotechnique internationale se reporter l une de ces deux publications IEC 1010 1 ou IEC 60664 Surtension cat gorie Niveau de signal Pi ces ou quipement lectronique et de t l communication Par exemple les circuits lectroniques prot
15. INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS GREENLEE CM 700 CM 750 iR DIGITAL CLAMP ON METERS MEDIDORES DIGITALES X3 CON PINZA MULTIMETRES NUMERIQUES A PINCES va COM A Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Lea y entienda todas las instrucciones y la informaci n sobre seguridad que aparecen en este manual antes de manejar estas herramientas o darles mantenimiento Lire attentivement et bien comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil 999 3789 1 2002 Greenlee Textron IM 1464 REV 1 3 02 GREENLEE Description The Greenlee CM 700 and CM 750 Digital Clamp on Meters are hand held testing devices with the following measurement capabilities AC and DC voltage AC and DC current and resistance They also verify continuity The display holds a measurement for later viewing or holds the maximum reading The CM 750 is a true RMS reading meter The jaw can accommodate a conductor up to 35 mm 1 38 in diameter In addition the meters feature the following Autoranging Zeroing key for DC amps Selectable auto power off Circuit protection to 600 volts 100 mA resolution up to 400 amps Safety Safety is essential in the use and maintenance of Greenlee tools and
16. a baja 10 Indicador de polaridad 11 DG Corriente continua 12 ae Corriente alterna 13 EM Selecci n autom tica de escala 14 Se activa la funci n Hold Retenci n de datos en pantalla 15 IN Aparece el valor maximo 16 GE Valor eficaz RMS CM 750 nicamente 17 Indicador de continuidad 13 14 15 16 18 M Mega 105 ERES 19 k Kilo 10 o z mmm GIB 20 Q Ohmios t Es 7 m T f1 3 21 m Mili 10 10 om sl 22 V Voltios VA 9 3 em wa m 23 A Amperios M T 7 24 30 00 Pantalla num rica 24 Simbolos en la unidad A Advertencia Lea el manual de instrucciones ol Doble forro aislante p 17 I 18 20 I 21 23 21 GREENLEE Como utilizar las distintas funciones e HOLD MAX Oprima moment neamente para retener en pantalla el valor que aparece en ese momento Oprima nuevamente para volver al modo normal Para utilizar la funci n Maximum Hold Valor M ximo opr malo y mant ngalo oprimido antes de encender la unidad Oprima nuevamente para restablecer el valor m ximo guardado Oprima y mantenga oprimido durante 2 segundos para regresar a la pantalla normal Para borrar la funci n Maximum Hold Valor M ximo apague y vuelva a encender la unidad ZERO A 0 Para mediciones de corriente continua cierre la pinza alrededor del conductor Para mayor precisi n oriente la pinza hacia la lectura positiva Retire
17. as instrucciones espec ficas para cada tipo de medici n 3 Pruebe la unidad en un circuito o componente que se sabe est funcionando perfectamente Sila unidad no funciona como deber a en un circuito que se sabe est funcionando perfectamente reemplace la pila Sisigue sin funcionar como deber a devu lvala a Greenlee a fin de que sea reparada Vea la direcci n bajo Garant a 4 Apnote la lectura del circuito o componente que se est verificando 5 Si se trata de una lectura de CC retire la pinza del circuito y oprima el bot n ZERO A Q Sujete nuevamente la pinza alrededor del circuito para medir la corriente continua real Tabla de valores coloque el interruptor de conecte el y conecte el Para medir selecci n en cable de cable de prueba este valor este s mbolo prueba rojo a negro a Q Continuidad y oprima V Q COM ZERO A Q Resistencia Q V Q COM Tensi n continua CC V V Q COM Tensi n alterna CA Ve V Q COM Corriente continua A Retire el cable Retire el cable 600 A max de prueba de prueba Corriente alterna A Retire el cable Retire el cable 600 A max de prueba de prueba Se emitir un sonido si la resistencia medida es menor de 50 Q aproximadamente y se apagar si es mayor de 300 Q 24 Mediciones mas comunes Medici n de tensi n Medici n de corriente Con la pinza colocada alrededor de un cable
18. d A ADVERTENCIA No haga funcionar esta unidad con la caja abierta Antes de abrir la caja retire del circuito los cables de prueba o la pinza y apague la unidad De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte A PRECAUCI N No cambie la funci n de medici n mientras los cables de prueba est n conectados a un componente o circuito De no observarse esta advertencia podr an sufrirse lesiones o da os a la unidad PRECAUCI N No intente reparar esta unidad ya que contiene partes que deben recibir mantenimiento por parte de un profesional No exponga la unidad a ambientes de temperatura extrema o altos niveles de humedad Consulte las Especificaciones De no observarse estas precauciones podr an sufrirse lesiones o da os a la unidad IMPORTANTE 20 A menos que vaya a medir tensi n o corriente apague y bloquee la energ a Aseg rese de que todos los condensadores est n totalmente sin carga No debe haber tensi n alguna Al utilizar esta unidad cerca de equipo que genere interferencia electromagn tica quiz se obtenga una lectura inexacta e inestable CM 700 CM 750 Identificaci n 1 Pinza Palanca Terminal de entrada COM com n Terminal de entrada V Q de voltios o resistencia Pantalla Selector Bot n de cero amperios de CC y encendido apagado con tono audible 8 Bot n retener m xima NOOR wD Iconos de la pantalla 9 Pil
19. ent des piles Enlever le couvercle du compartiment pile Remplacer la pile suivre la polarit SYS eor Replacer le couvercle et remettre la vis Nettoyage Nettoyer r guli rement le bo tier avec un chiffon humide et un d tergent doux Ne pas utiliser de produits abrasifs ou de solvants 47 Lifetime Limited Warranty Greenlee warrants to the original purchaser of these goods for use that these products will be free from defects in workmanship and material for their useful life excepting normal wear and abuse This warranty is subject to the same terms and conditions contained in Greenlee s standard one year limited warranty For all Test Instrument repairs ship units Freight Prepaid to Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 USA Mark all packages Attention TEST INSTRUMENT REPAIR For items not covered under warranty such as dropped abused etc repair cost quote available upon request Note Prior to returning any test instrument please check replaceable batteries or make sure the battery is at full charge Garantia limitada de por vida Greenlee garantiza al comprador original de estos productos para su uso que estos productos estar n libres de defectos de mano de obra y materiales durante toda su vida util exceptuando el desgaste normal y el abuso Esta garantia esta sujeta a los mismos t rminos y condiciones contenidos en la garantia estandar limitada de Greenlee de un afio de duraci
20. ento de las pilas Reemplace la pila f jese en la polaridad E LEE ae A eor Vuelva a colocar la puerta y el tornillo Limpieza Limpie peri dicamente la caja utilizando un pafio himedo y detergente suave no utilice abrasivos ni solventes 31 GREENLEE Greenlee Textron Subsidiary of Textron Inc 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 CM 700 CM 750 Description Les multim tres a pinces analogiques CM 700 et CM 750 de Greenlee sont des appareils portables con us pour mesurer la tension c a et c c le courant c a et c c de m me que la r sistance Ils v rifient galement la continuit L afficheur maintient une mesure afin qu elle puisse tre lue plus tard ou maintient la lecture maximum Le CM 750 est un multim tre lecture efficace vraie RMS La pince peut s adapter un conducteur d un diam tre pouvant aller jusqu 35 mm 1 38 po De plus les multim tres sont dot s des fonctions suivantes S lection automatique de la plage Touche de remise z ro pour les amp res c c Mise hors tension automatique Protection de circuit jusqu 600 volts R solution de 100 mA jusqu 400 amp res S curit Lors de l utilisation et de l entretien des outils et des quipements de Greenlee votre s curit est une priorit Ce manuel d instructions et toute tiquette sur l outil fournit des informations permettant d viter des dangers ou des manipulations dangereuses
21. equipment This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool Observe all of the safety information provided Purpose This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for Greenlee CM 700 and CM 750 Digital Clamp on Meters Keep this manual available to all personnel Replacement manuals are available upon request at no charge Greenlee and are registered trademarks of Greenlee Textron KEEP THIS MANUAL CM 700 CM 750 Important Safety Information SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage The signal word defined below indicates the severity of the hazard The message after the signal word provides information for preventing or avoiding the hazard ADANGER Immediate hazards which if not avoided WILL result in severe injury or death AWARNING Hazards which if not avoided COULD result in severe injury or death ACAUTION Hazards or unsafe practices which if not avoided MAY result in injury or property AWARNING Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool can result in an accident causing serious injury or death GREENLEE Imp
22. g Position the jaw for a positive reading for highest accuracy 10 CM 700 CM 750 Typical Measurements Current Measurement Clamp Around Line Splitter Notes e The Greenlee 93 30 Line Splitter is divided One section renders amps the other renders amps multiplied by 10 Close the jaw completely to ensure accurate measurement Z SUG Center the line splitter in the jaw for highest accuracy Resistance Measurement 11 GREENLEE Accuracy See the Specifications section for operating conditions and temperature coefficient Accuracy is specified as follows a percentage of the reading a fixed amount at 18 C to 28 C 64 F to 82 F for voltage and resistance measurements e 21 C to 26 C 70 F to 79 F for current measurements 0 to 80 relative humidity AC Current 21 C to 26 C for CM 700 0 0 to 40 0 1 9 0 7 A 2 5 0 7 A 40 0 to 200 0 1 9 0 5 A 2 5 0 5 A 200 0 to 400 0 3 0 0 5 A 3 6 0 5 A 400 to 600 1 9 10 2 5 10 A AC Current 21 C to 26 C for CM 750 0 0 to 40 0 1 9 0 7 A 2 5 0 7 A 40 0 to 200 0 1 9 0 5 A 2 5 0 5 A 200 0 to 400 0 3 5 0 5 A 3 6 0 5 A 400 to 600 1 9 10 A 2 5 10 A AC Voltage 18 C to 28 C for CM 700 and CM 750 400 0
23. g s contre les courants transitoires dans les photocopieurs et les modems Surtension cat gorie II Niveau local Appareils quipement portatif et les circuits dans lesquels ils sont branch s Par exemple les appareils d clairage les t l viseurs et les d rivations Surtension cat gorie III Niveau de distribution Les machines install es en permanence et les circuits auxquels elles sont c bl es Par exemple les syst mes de convoyeurs et les panneaux de disjoncteurs principaux du syst me lectrique d un difice Surtension cat gorie IV Niveau d alimentation principal Lignes sur lev es et autres syst mes de c bles Par exemple les cables les multim tres les transformateurs et autres quipements ext rieurs appartenant aux fournisseurs en lectricit 46 CM 700 CM 750 Entretien A ATTENTION e Ne pas tenter de r parer cet appareil ne comporte aucune pi ce pouvant tre r par e Ne pas exposer l appareil des temp ratures ou une humidit extr mes Voir les sp cifications L inobservation de ces consignes peut endommager l appareil et entrainer des blessures Remplacement des piles A AVERTISSEMENT Avant d ouvrir le bo tier retirer les fils d essai du circuit et mettre l appareil hors tension L inobservation de cette consigne peut entrainer des blessures graves voire mortelles D brancher l appareil du circuit Enlever la vis du couvercle du compartim
24. is 3 x 10 digits on the 400 0 volt range or 3 0 volts Note Maximum hold accuracy for resistance is specified on 400 0 Q to 400 0 kQ ranges only 13 GREENLEE Specifications Display 3 3 4 digit LCD 3999 maximum count Sampling Rate 2 per second Jaw Opening 35 mm 1 38 Overvoltage Protection Category Category III 600 V Temperature Coefficient 0 2 x Accuracy per C above or below range specified in the Accuracy section Operating Conditions 0 C to 30 C 32 F to 86 F 0 to 80 relative humidity non condensing 30 C to 40 C 86 F to 104 F 0 to 75 relative humidity non condensing 40 C to 50 C 104 F to 122 F 0 to 45 relative humidity non condensing Note Current measurement is limited to 40 C 104 F Indoor use only Storage Conditions 20 C to 60 C 4 F to 131 F 0 to 70 relative humidity non condensing Remove battery Elevation 2000 m 6500 maximum Pollution Degree 2 Battery One 9 V battery NEDA 1604 JIS 006P or IEC 6F22 Battery Life Approximately 150 hours with alkaline battery 14 CM 700 CM 750 Overvoltage Installation Categories These definitions were derived from the international safety standard for insulation coordination as it applies to measurement control and laboratory equipment These overvoltage categories are explained in more detail by the International Electrotechnical Commission refer to either of their publications
25. l Pour d sactiver la fonction de maintien maximum mettre l appareil hors tension puis sous tension de nouveau ZERO AF Q Pour effectuer des mesures de courant c c fermer la pince autour du conducteur Orienter la pince de fa on obtenir la lecture positive la plus pr cise Enlever la pince du conducteur et la fermer Appuyer sur le bouton ZERO A Cette op ration compense pour le magn tisme r siduel pr sent dans la pince Placer la pince sur le conducteur en gardant la m me orientation et prendre la lecture Pour obtenir des mesures continues appuyer pour activer la tonalit L ic ne xj appara t sur l afficheur et le multim tre passe la plage de 400 Q Appuyer de nouveau pour mesurer la r sistance D sactivation de la mise hors tension automatique Placer le s lecteur la position OFF Maintenir enfonc le bouton ZERO A O 9 tout en pla ant le s lecteur la position Q L appareil reste sous tension jusqu ce que s lecteur soit plac OFF ou jusqu ce que la pile soit trop faible environ 150 heures pour une pile alcaline neuve La mise hors tension automatique apr s 30 minutes sera r activ e lors de prochaine mise sous tension CM 700 CM 750 Mesure du c a En r gle g n rale les mesures du c a sont affich es en valeurs RMS moyenne effective La valeur RMS quivaut la valeur d une forme d onde c c qui fournirait la m me puissance si elle remplacait la for
26. la pinza del conductor y ci rrela Oprima el bot n ZERO A Esto compensar el magnetismo residual en la pinza Coloque la pinza sobre el conductor manteniendo la misma orientaci n y anote la lectura Para mediciones de continuidad oprima para activar el tono El icono aparece en la pantalla y el medidor cambia a la gama de 400 O Oprima nuevamente para medir resistencia Desactivaci n del apagado autom tico Gire el interruptor de selecci n a la posici n OFF apagado Oprima y mantenga oprimido el bot n ZERO A 0 2 a la vez que gira r pidamente el interruptor de selecci n a la posici n Q La unidad permanecer ahora encendida hasta que el selector sea colocado en OFF o hasta que la pila se agote aproximadamente 150 horas para una pila alcalina nueva La pr xima vez que se encienda la unidad el Apagado autom tico de 30 minutos ser activado 22 CM 700 CM 750 Medici n de corriente alterna Las mediciones de corriente alterna generalmente se muestran como valores eficaces RMS o root mean squared El valor eficaz equivale al valor de una forma de onda de CC la cual brinda la misma potencia que si reemplazara la forma de onda variable con el tiempo Existen dos m todos de medici n de corriente alterna calibrados para responder al valor eficaz medio yauna lectura de valores eficaces reales El m todo calibrado para responder al valor eficaz medio toma el valor medio de la se al de entrada
27. luego de una rectificaci n total de onda la multiplica por 1 11 y muestra el resultado El resultado es exacto si la sefial de entrada es una onda sinusoidal pura El modelo CM 700 de Greenlee es un mult metro que responde al valor medio El m todo de lectura de valores eficaces reales utiliza un circuito interno para leer el valor eficaz real Este m todo es exacto dentro de las limitaciones de factor de cresta especificadas independientemente del tipo de se al de entrada ya sea una onda sinusoidal pura rectangular triangular media onda o se al con arm nicas La capacidad para leer valores eficaces reales brinda una mayor versatilidad de medici n La unidad modelo CM 750 de Greenlee es un medidor de valores eficaces reales La tabla de Formas de onda y Factores de cresta muestra algunas de las sefiales de CA y sus valores eficaces reales m s comunes Formas de onda y Factores de cresta Forma de onda 29 Valor eficaz Valor medio Factor de cresta 5 El factor de cresta es el cociente de un valor maximo en relaci n con el valor eficaz est representado por la letra griega amp 23 GREENLEE Operacion A ADVERTENCIA Peligro de electrocuci n El contacto con circuitos activados puede ocasionar graves lesiones o incluso la muerte 1 Coloque el interruptor de selecci n de acuerdo con la Tabla de valores 2 Consulte la secci n Mediciones m s comunes en relaci n con l
28. me d onde qui varie en fonction du temps Les deux m thodes de mesure du c a sont talonn es pour une r ponse moyenne RMS et une lecture RMS vraie La m thode par r ponse moyenne consiste mesurer la valeur moyenne du signal d entr e apr s un redressement onde pleine la multiplier par 1 11 et afficher le r sultat Cette m thode est pr cise si le signal d entr e est une onde sinusoidale pure Le Greenlee CM 700 mesure la r ponse moyenne La m thode par mesure de la valeur efficace vraie RMS fait appel un circuit interne permettant de mesurer directement la valeur efficace Cette m thode est pr cise dans les limites du facteur de cr te sp cifi es que le signal soit une onde sinusoidale pure une onde carr e une onde triangulaire une demi onde ou un signal comportant des harmoniques Les appareils mesure de valeur efficace vraie RMS sont beaucoup plus polyvalents que les appareils conventionnels Le multim tre CM 750 de Greenlee lit la valeur efficace vraie RMS Le tableau des formes d onde et facteurs de cr te fournit les valeurs efficaces des signaux alternatifs courants Formes d ondes et facteurs de cr tes Forme d onde Co Valeur RMS Valeur moyenne Facteur de cr te 5 Le facteur de cr te correspond au ratio de la valeur de cr te par rapport la valeur RMS il est repr sent par la lettre grecque 39 GREENLEE Utilisation AVERTISSEMENT
29. n Para reparaci n de instrumentos de verificaci n env e las unidades con flete pagado a Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 EE UU Marque todos los paquetes Atenci n TEST INSTRUMENT REPAIR Reparaci n de instrumentos de verificaci n Para art culos no cubiertos por la garant a tales como los que se han dejado caer o han sido maltratados etc se puede Cotizar el costo de la reparaci n a pedido Nota Antes de enviar cualquier instrumento de verificaci n revise por favor las pilas o asegurese de que est n totalmente cargadas Garantie vie limit e La soci t Greenlee garantit l acheteur d origine de ces produits que ces derniers ne comportent aucun d faut d ex cution ou de mat riau pour la dur e de leur vie utile sauf l usure normale Cette garantie est assujettie aux m mes conditions que celles contenues dans les modalit s et conditions de la garantie limit e standard d un an de Greenlee Pour toutes les r parations d instruments de mesure exp diez l appareil en port pay l adresse suivante Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 Etats Unis Sur tous les colis inscrivez Attention TEST INSTRUMENT REPAIR R paration d instrument de mesure Lorsque les articles ne sont pas prot g s par une garantie comme si l appareil est chapp s il est soumis un usage abusif etc une soumission pour le prix de r paration sera pr sent e sur demande
30. nce est sup rieure 300 Q 40 Mesures types Mesure de la tension Mesure du courant Serrer la pince autour du cable CM 700 CM 750 Remarques e Serrer la pince autour d un seul conducteur Fermer compl tement la pince pour garantir une mesure exacte Pour plus de pr cision centrer le c ble dans la pince Remarque Lors des mesures du courant c c le courant qui circule travers la pince dans la direction indiqu e par la fl che produit une lecture positive Placer la pince de fa on obtenir la lecture positive la plus pr cise 41 GREENLEE Mesures types Mesure du courant Mettre la pince autour d un s parateur de ligne Remarques Le s parateur de ligne 93 30 de Greenlee est divis Une section donne des amp res l autre des amp res multipli s par 10 e Fermer compl tement la pince pour garantir une mesure exacte Pour plus de pr cision centrer le s parateur de ligne dans la pince Mesure de la r sistance 42 CM 700 CM 750 Pr cision Pour obtenir les conditions d utilisation et les coefficients de temp rature consulter la section sur les sp cifications La pr cision est sp cifi e comme suit un pourcentage de la lecture une quantit fixe e 18 28 C 64 82 F pour les mesures de tension et de r sistance e 21426 C 70 79 F pour les mesu
31. odelo CM 700 Precisi n 50 a 60 Hz Precisi n 60 a 400 Hz 0 0 a 40 0 X 1 9 40 7 A 2 5 40 7 A 40 0 a 200 0 t 1 9 40 5 A 2 5 40 5 A 200 0 a 400 0 3 0 40 5 A 3 6 40 5 A 400 a 600 1 9 410A 2 5 10 A Corriente alterna 21 C a 26 C para el modelo CM 750 0 0 a 40 0 1 9 0 7 A 2 5 0 7 A 40 0 a 200 0 1 9 0 5 A 2 5 0 5 A 200 0 a 400 0 3 596 0 5 A 3 696 0 5 A 400 a 600 1 9 10 A 2 5 10 A Tensi n CA 18 C a 28 C para los modelos CM 700 y CM 750 400 0 mV No especificada No especificada 4 000V 1 5 0 005V 40 a 300 Hz 40 00V 1 5 0 05V 9 MQ 100 pF 400 0V 1 5 0 5V 40 a 500 Hz 600V x 1 5 45V El modelo CM 700 es calibrado para responder al valor eficaz medio El modelo CM 750 detecta valores eficaces reales La precisi n se especifica para ondas sinusoidales a plena escala y ondas no sinusoidales por debajo de la escala media Para ondas no sinusoidales afiada las siguientes correcciones al factor de cresta Factor de cresta de 1 4 a 2 0 a ada 1 0 Factor de cresta de 2 0 a 2 5 a ada 2 5 Factor de cresta de 2 5 a 3 0 a ada 4 0 27 GREENLEE Precisi n continuaci n Corriente continua 21 C a 26 C Escala Valor de entrada Precisi n 0 0 a 40 0 1 5 1 0 A 40 0 a 200 0 1 5 0 7 A 200 0 a 400 0 2 5 40 7 A 400 a 600 1
32. on a known functioning circuit or component e f the unit does not function as expected on a known functioning circuit replace the battery e If the unit still does not function as expected send the unit to Greenlee for repair See the address shown under Warranty 4 Take the reading from the circuit or component to be tested 5 Ifitis a DC reading remove the clamp from the circuit and press the ZERO A 0 2 button Clamp the jaw around the circuit again to measure the actual DC current Settings Table To measure set the selector connect the and connect the this value to this symbol red lead to black lead to Q Continuity and press V Q COM ZERO A Q Resistance O 1 V Q COM DC Voltage V Q COM AC Voltage V Q COM DC Current 600 A max Remove lead Remove lead AC Current 600 A max Remove lead Remove lead Tone sounds if the measured resistance is less than approximately 50 Q and turns off when greater than approximately 300 Q GREENLEE Typical Measurements Voltage Measurement Current Measurement Clamp Around Wire Notes Clamp the jaw around one conductor only e Close the jaw completely to ensure accurate measurement e Center the wire in the jaw for highest accuracy Note For DC measurements current flowing through the jaw in the direction indicated by the arrow produces a positive readin
33. ortant Safety Information AWARNING Electric shock hazard Contact with live circuits can result in severe injury or death AWARNING Electric shock and fire hazard Do not expose this unit to rain or moisture Do not use the unit if it is wet or damaged Use test leads or accessories that are appropriate for the application See the category and voltage rating of the test lead or accessory Inspect the test leads or accessory before use They must be clean and dry and the insulation must be in good condition Use this unit for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe these warnings can result in severe injury or death AWARNING Electric shock hazard Do not apply more than the rated voltage between any two input terminals or between any input terminal and earth ground Do not contact the test lead tips or any uninsulated portion of the accessory Failure to observe these warnings can result in severe injury or death CM 700 CM 750 Important Safety Information AWARNING Do not operate with the case open Before opening the case remove the test leads or jaw from the circuit and shut off the unit Failure to observe these warnings can result in severe injury or death ACAUTION Do not change the measurement function while the test leads are connected to a component or ci
34. proc der l entretien de cet quipement N gliger de comprendre comment utiliser cet outil en toute s curit peut provoquer un accident et entrainer des blessures graves voire mortelles Consignes de s curit CM 700 CM 750 importantes A AVERTISSEMENT Risques de d charge lectrique Un contact avec des circuits sous tension peut entrainer des blessures graves voire mortelles A AVERTISSEMENT Risques de d charge lectrique et d incendie Ne pas exposer cet apparei Ne pas utiliser cet appareil la pluie ou l humidit S il est mouill ou endommag Utiliser des fils d essai ou des accessoires conformes l application Consulter la cat gorie et la tension nom V rifier les fils d essai ou I doi ven t tre propre s et inale du fil d essai ou de l accessoire accessoire avant de les utiliser La pi ce ou les pi ces s che s et l isolation en bon tat Utiliser cet appareil unique ment dans le but pour lequel il a t concu tel que d crit dans ce manuel Toute autre utilisation peut alt rer le syst me de protection de cet appareil L inobservation de ces consig nes peut entrainer des blessures graves voire mortelles AVERTISSEMENT Risques de d charge lectrique Ne pas appliquer plus que la tension nominale entre deux bornes d entr e ou entre une borne d entr e et une prise de terre Ne pas entrer en contact avec le
35. r que la gama especificada en la secci n Precisi n Condiciones de operaci n 0 C a 30 C 32 F a 86 F 0 a 80 de humedad relativa sin condensaci n 30 C a 40 C 86 F a 104 F 0 a 75 de humedad relativa sin condensaci n 40 C a 50 C 104 F a 122 F 0 a 45 de humedad relativa sin condensaci n Aviso La medici n de corriente se limita a 40 C 104 F Uso en interiores nicamente Condiciones de almacenamiento 20 C a 60 C 4 F a 131 F 0 a 70 de humedad relativa sin condensaci n Retire la pila Altura 2 000 m 6 500 pies m ximo Grado de contaminaci n 2 Pila Pila de 9 voltios NEDA 1604 JIS 006P o IEC 6F22 Vida til de la pila Aproximadamente 150 horas con pila alcalina 29 GREENLEE Categorias de instalaci n de sobretensi n Las siguientes definiciones proceden de la norma de seguridad internacional sobre la coordinaci n de aislamientos tal y como se aplica a equipos de medici n control y laboratorio En las publicaciones IEC 1010 1 y IEC 60664 de la International Electrotechnical Commission Comisi n Electrot cnica Internacional se detallan m s a fondo estas categor as de sobretensi n Categor a de sobretensi n I Nivel de sefial Equipo electr nico y de telecomunicaciones o partes del mismo Como ejemplo pueden citarse los circuitos electr nicos protegidos contra tensiones moment neas dentro de fotocopiadores y modems Categor a de sobretensi n Il Nivel
36. rcuit Failure to observe this precaution can result in injury and can damage the unit ACAUTION Do not attempt to repair this unit It contains no user serviceable parts Do not expose the unit to extremes in temperature or high humidity See Specifications Failure to observe these precautions can result in injury and can damage the unit IMPORTANT Unless measuring voltage or current shut off and lock out power Make sure that all capacitors are discharged Voltage must not be present Using this unit near equipment that generates electromagnetic interference can result in unstable or inaccurate readings GREENLEE Identification Jaw Lever Common COM input terminal Volts or resistance V Q input terminal Display Selector Zero amp DC button and beeper on off CO NT CD GO E O NOE Hold maximum button Display Icons 9 Low battery 10 Polarity indicator 11 DG Direct current 12 ae Alternating current 13 Autoranging 14 Hold is enabled 15 IN Maximum value is displayed 16 GE Root mean square CM 750 only 3 4 17 a Continuity indicator 13 14 15 16 18 M Mega 105 19 k Kilo 10 yo x mmm GI 20 2 Ohms ote ANN 21 m Milli 103 10 e ILILILI 22 V Volts mVA 4 9 H a oe a 23 A Amps 24 30 00 Numeric display Symbols on the Unit A Warning Read the instruction manual E Double insulation 6 24
37. res courantes e 0480 d humidit relative Courant c a 21 26 C pour le CM 700 0 0 40 0 1 9 0 7 A 2 5 0 7 A 40 0 200 0 1 9 96 0 5 A 2 596 0 5 200 0 400 0 3 0 0 5 A 3 6 0 5 A 400 600 1 9 10 2 5 10 Courant c a 21 26 C pour le CM 750 0 0 40 0 1 9 96 0 7 A 2 5 0 7 A 40 0 200 0 1 9 0 5 A 2 5 0 5 A 200 0 400 0 3 5 0 5 A 3 6 0 5 A 400 600 t 1 996 10 A X 2 5 10 A Tension c a 18 28 C pour le CM 700 et le CM 750 400 0 mV Non sp cifi e Non sp cifi e 4 000 V 1 5 0 005 V 40 300 Hz 40 00 V 1 5 0 05 V 9 MQ 100 pF 400 0 V t 1 5 0 5 V 40 500 Hz 600 V 15 5V La saisie du CM 700 est talonn e pour une valeur efficace vraie RMS moyenne Le CM 750 mesure la valeur efficace vraie RMS La sp cification de pr cision du c a s applique aux ondes sinusoidales a leur pleine chelle et aux ondes non sinusoidales inf rieures la demi grandeur Pour les ondes non sinusoidales ajouter les corrections de facteur de cr te suivantes Facteur de cr te de 1 4 2 0 1 0 Facteur de cr te de 2 0 2 5 2 5 Facteur de cr te de 2 5 3 0 4 0 43 GREENLEE Pr cision suite Courant c c 21 a 26 C Plage Valeur d entr e Pr cision 0 0 40 0 1 5 1 0A
38. rve polarity OY aee M ee Replace the door and the screw Cleaning Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents 16 CM 700 CM 750 Descripci n Los Medidores digitales con pinza modelos CM 700 y CM 750 de Greenlee son instrumentos de verificaci n capaces de efectuar los siguientes tipos de mediciones tensi n alterna y continua corriente alterna y continua y resistencia Esta unidad es de bolsillo y cabe perfectamente en la palma de la mano Tambi n sirven para verificar continuidad La pantalla retiene una medici n para verla m s tarde o retiene la lectura m xima El modelo CM 750 es un mult metro de lectura de valores eficaces reales La pinza se adapta a conductores de hasta 35 mm 1 38 pulg de di metro Adem s los medidores incluyen lo siguiente Selecci n autom tica de escala Tecla para ajuste en cero para amperios de CC Apagado autom tico seleccionable Protecci n de circuitos hasta 600 voltios Resoluci n de 100 mA hasta 400 amperios Acerca de la seguridad Es fundamental observar m todos seguros al utilizar y dar mantenimiento a las herramientas y equipo Greenlee Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la informaci n necesaria para evitar riesgos y h bitos poco seguros relacionados con su uso Siga toda la informaci n sobre seguridad que se proporciona Prop sito de este manual
39. s extr mit s des fils d essai ou avec toute autre partie non isol e de l accessoire L inobservation de ces consig nes peut entrainer des blessures graves voire mortelles 35 GREENLEE Consignes de s curit importantes A AVERTISSEMENT Ne pas utiliser lorsque le bo tier est ouvert Avant d ouvrir le bo tier retirer les fils d essai ou la pince du circuit et mettre l appareil hors tension L inobservation de ces consignes peut entrainer des blessures graves voire mortelles ATTENTION Ne pas modifier la fonction de mesure pendant que les fils d essai sont connect s un composant ou un circuit L inobservation de cette consigne peut endommager l appareil et entrainer des blessures A ATTENTION e Ne pas tenter de r parer cet appareil II ne comporte aucune pi ce pouvant tre r par e Ne pas exposer l appareil des temp ratures ou une humidit extr mes Voir les sp cifications L inobservation de ces consignes peut endommager l appareil et entrainer des blessures IMPORTANT Saufsi l on mesure la tension ou le courant mettre hors tension et verrouiller la source d alimentation S assurer que tous les condensateurs sont d charg s Aucune tension ne doit tre pr sente e L utilisation de cet appareil proximit d quipements qui g n rent des interf rences lectromagn tiques peut produire des lectures instables ou erron es 36 CM 700 CM 7
40. square values The RMS value is equal to the value of a DC waveform which would deliver the same power if it replaced the time varying waveform Two AC measurement methods are average responding RMS calibrated and true RMS reading The average responding RMS calibrated method takes the average value of the input signal after full wave rectification multiplies it by 1 11 and displays the result This method is accurate if the input signal is a pure sine wave The Greenlee CM 700 is an average responding meter The true RMS reading method uses internal circuitry to read the true RMS value This method is accurate within the specified crest factor limitations whether the input signal is a pure sine wave square wave triangle wave half wave or signal with harmonics The ability to read true RMS provides much more measurement versatility The Greenlee CM 750 is a true RMS meter The Waveforms and Crest Factors table shows some typical AC signals and their RMS values Waveforms and Crest Factors RMS Value Average Value Crest Factor 8 The crest factor is the ratio of the peak value to the RMS value it is represented by the Greek letter 8 CM 700 CM 750 Operation AWARNING Electric shock hazard Contact with live circuits can result in severe injury or death 1 Set the selector according to the Settings Table 2 See Typical Measurements for specific measurement instructions 3 Test the unit