Home

MBE - Vratcom

image

Contents

1. Ingresso pulsante pedonale O O Input pedestrian entrance push button Eingang FuBg ngereingang Taste O NT Entr e bouton entr e pi tonne 120 Entrada pulsador entrada de peatones o Wej cie dla przycisku no nego 24 190 o Wues FT O O NZ RADIO ANT Y Y O seo NO de Ee e NO PPP SCA s S E X zac no IST O 3W max SS NCL e opd EI 3 V en S 3 24Vac 0 S z 0 5A max o S z L LL 30 de mb D4 Ke EN 12v a ER avec 29 q p Ke PGM DO 2005 a SSpu DO gt Sr er gt 2 SIE GIN A F2 2A gt 93 3j a 2 gt o gt O OOO CE 18 19 20 21 L N LAMP 230VAC 930Vac 50Hz Centrale di comando per MBE La centrale elettronica MBE pu essere utilizzata per il controllo di 1 o 2 motori MB MBE AVVERTENZE GENERALI a L installazione elettrica e la logica di funzionamento devono essere in accordo con le normative vigenti b I conduttori alimentati con tensioni diverse devono essere fisicamente separati oppure devono essere adeguatamente isolati con isolamento supplementare di almeno 1 mm c I conduttori devono essere vincolati da un fissaggio supplementare in prossimit dei morsetti d Ricontrollare tutti i collegamenti fatti prima di dare tensione e Controllare che le impostazioni dei Dip Switch siano quelle volute D Gli ingressi N C non utilizzati devono essere pontic
2. To check connections After adjusting the limit switches as shown in the actuator instruction manual proceed as follows 1 Cut off power supply 2 Manually release the wings move them to approx half stroke and lock them again 3 Reset power supply 4 Send a step by step control signal by pressing the button or the remote control key 5 The wings should start an opening movement If this is not the case invert the movement wires of the motor 22 23 for motor MB and 25 26 for motor MBE 6 Adjust Time Operating Logic and Motor Power To adjust the motor power WARNING This adjustment affects the safety of the automatic system Check that the thrust applied onto the wing complies with regulations in force A Faston POWER connector is provided on the power supply transformer which allows the power adjustment of the motors on 3different levels By moving the Faston POWER to 120 power is at minimum by moving it to 190 power is at maximum WARNING As the MB MBE actuator is not equipped with adjustable mechanical clutch the POWER faston must never be moved to 230V position Dip Switch functions DIP1 PP Mod The operating mode of Pulsante P P Step by step push button and of the transmitter is selected Off operation APRE gt STOP gt CHIUDE gt STOP gt On operation APRE gt CHIUDE gt APRE gt DIP2 C A Automatic closure is enabled or disabled Off disabled automat
3. 12 Funci n Dip Switch DIP1 PP Mod Selecciona la modalidad de funcionamiento del Bot n P P y del transmisor Off Funcionamiento ABRE gt STOP gt CIERRA gt STOP gt On Funcionamiento ABRE gt CIERRA gt ABRE gt DIP2 C A Habilita o inhabilita el cierre autom tico Off cierre autom tico inhabilitado On cierre autom tico habilitado DIP3 Com Habilita o inhabilita la funci n comunidad Off Funci n comunidad inhabilitada On Funci n comunidad habilitada El impulso P P o del transmisor no tiene efecto durante la fase de apertura DIP A Prelam Habilita o inhabilita la pre intermitencia Off Intermitencia previa inhabilitada On Intermitencia previa habilitada El intermitente se activa 3 s antes del arranque del motor Nota Despu s de cada modificaci n de los ajustes de los trimmer y de los Dip switch cortar y dar de nuevo la alimentaci n de red Funci n de los Trimmer TCA Permite ajustar el tiempo de cierre autom tico Comprobar el Dip Switch N 2 On La regulaci n var a entre un m nimo de 1 s y un m ximo de 125 s TL Ajusta la duraci n m xima de la maniobra de apertura y cierre Debe programarse en aproximadamente 4 seg m s que el tiempo de carrera efectiva del automatismo La regulaci n var a entre un m nimo de 5 s y un m ximo de 130 s Nota En el caso de apertura cierre parcial la central calcula el tiempo restante para completar la maniobra a fin de ev
4. condominiale disabilitata On Funzione condominiale abilitata L impulso P P o del trasmettitore non ha effetto durante la fase di apertura DIP4 Prelam Abilita o disabilita il prelampeggio Off Prelampeggio disabilitato On Prelampeggio abilitato Il lampeggiante si attiva 3 s prima della partenza del motore Nota Dopo ogni modifica delle impostazioni dei trimmer e dei Dip switch togliere e ridare alimentazione di rete Funzione dei Trimmer TCA Permette di regolare il tempo di chiusura automatica Verificare il Dip Switch N 2 On La regolazione varia da un minimo di 1 s ad un massimo di 125 s TL Regola la durata massima della manovra di apertura e chiusura Deve essere impostato circa 4 sec in pi rispetto al tempo di corsa effettiva dell automatismo La regolazione varia da un minimo di 5 s ad un massimo di 130 s Nota Nel caso di apertura chiusura parziale la centrale calcola il tempo restante al completamento della manovra in modo da evitare inutili surriscaldamenti del motore TRAC Permette di regolare il tempo di ritardo con cui il motore MBE inizia la manovra di chiusura rispetto al motore MB La regolazione varia da un min di 3 s a un max di 30 s In apertura il tempo di sfasamento dei motori di 2 secondi Configurazione ricevitore incorporato La centrale dotata di un modulo radio incorporato per la ricezione di telecomandi sia a codice fisso che a codice variabile alla frequenza di 433 92MHz Per ut
5. llena y no es posible memorizar otros transmisores Funciones LEDs LED D2 Encendido con presencia de la alimentaci n de red LEDD4 Programaci n receptor radio LEDD5 Se enciende ante se ales radio en la frecuencia del modulo incorporado 13 Centralka dla MBE Elektroniczna centralka MBE mo e by u ywana do sterowania 1 lub 2 silnikami MB MBE Wskaz wki dla instalacji UWAGI OG LNE a Instalacja elektryczna i spos b funkcjonowania musz by zgodne z obowi zuj cymi normami b Przewody zasilania o r nym napi ciu musz by odzielone od siebie albo odpowiednio izolowane z zastosowaniem dodatkowej przynajmniej 1 milimetrowej warstwy izolacyjnej c W pobli u zacisk w przewody musz mie dodatkowe zamocowanie d Przed w czeniem napi cia nale y sprawdzi wszystkie po czenia e Sprawdzi czy wszystkie ustawienie dip switch w s w danej pozycji f Nieuzywane wej cia N C normalnie zwarte nale y zmostkowa FUNKCJE WEJ WYJ Nr Zacisku Funkcja Opis 1 ANT Znak dla Anteny 2 SHIELD Ekran Anteny 3 8 SCA Po czenie lampki kontrolnej brama otwarta 24 Vac 3W max 4 P P Wej cie przycisku posuw posuw N O 5 STOP Wej cie przycisku STOP N C 6 FTC Wej cie po cze urz dze bezpiecze stwa zestyk N C normalnie zwarty na przyk ad fotokom rki 7 V Wsp lny dla wszystkich wej sterowania 8 9 24 Vac Wyj cie zasilania dod
6. nych kod w Zapisywanie w pami ci nowego nadajnika z aktywacj funkcji P P Wcisn jeden raz przycisk PGM przez 2 sekundy led D4 zaczyna b yska z du cz stotliwo ci szybko W ci gu nast pnych 10 sekund nale y wcisn przycisk nadajnika z funkcj P P kt ry ma by wprowadzony do pami ci Kasowanie nadajnik w z pami ci Od czy zasilanie centralki Przywr ci zasilanie trzymaj c wci ni ty przycisk PGM przez 5 sekund led D4 zapali si sta ym wiat em i zga nie po zako czeniu procesu kasowania Zwolni przycisk PGM dane zosta y wykasowane z pami ci i led D 4 b dzie si wieci wiat em normalnym UWAGA Je eli podczas procedury zapisywania w pami ci danych nadajnik w LED D4 za wieci si dwukrotnie d ugim wiat em a nast pnie zga nie oznacza to e pami odbiornika jest pe na i nie ma mo liwo ci zapisywania innych nadajnik w przestawiaj c go na 230 uzyskuje si wy szy poziom mocy Funkcje LED W LED D2 Za wieci si przy obecno ci zasilania z sieci LED D4 Programowanie radioodbiornika LED D5 Za wieci si przy obecno ci sygna w radiowych o cz stotliwo ci wbudowanego modu u 15 BENINCA AUTOMATISMI BENINCA SpA Via Capitello 45 36066 Sandrigo VI Tel 0444 751030 r a Fax 0444 759728
7. ouvert 24 Vac 3W max 4 P P Entr e touche pas a pas N O 5 STOP Entr e touche STOP N C 6 FTC Entr e connexion dispositif de s curit contact N C es photocellules 7 V Commun pour toutes les entr es de commande 8 9 24 Vac Sortie alimentation accessoires 24Vac 0 5A max 10 11 ELS Connexion serrure lectrique 12Vac 0 5A max 12 13 14 24 12 0 Connexion enroulement secondaire transformateur 15 16 17 POWER NT FT Connexion enroulement primaire transformateur 18 19 Input 230 Vac Entr e 230Vac 50Hz 1 Phase 2 Neutre 20 21 LAMP Sortie connexion clignotant 230Vac 40W max 22 23 24 Moteur MB Connexion au moteur MB sans centrale de commande 22 marche 23 marche 24 com 24 25 26 Moteur MBE Connexion au moteur MBE avec centrale de commande 24 com 25 marche 26 marche Entr e pi tonniere Sion d sire utiliser l entr e pi tonniere connecter un bouton normalement ouvert N O entre V commun des commandes et le t ton situ pr s de la borne STOP voir sch ma V rification des connexions Apr s avoir r gl les fins de course de la mani re indiqu e dans le manuel d instructions de l actionneur suivre la marche ci dessous 1 Couper le courant D bloquer manuellement les vantaux les placer environ mi course et les bloquer nouveau Restaurer le courant Donner une commande de pas pas en appuyant sur la touche ou la radiocommande Les vantaux doivent se d placer en ouverture Au cas contra
8. sec eingestellt werden Bemerkung bei unvollst ndigem ffnungs Schlie vorgang rechnet die Zentrale die restliche Zeit bis zur Vervollst ndigung der Bewegung aus um den Motor nicht unn tig zu belasten und zu berhitzen TRAC Erm glicht es die Verz gerung mit welcher der Motor MBE den Fl gel im Verh ltnis zum Motor MB schlie t einzustellen Die Zeit kann zwischen 3 s und max 30 sec eingestellt werden Beim ffnen betr gt der Unterschied zwischen den Motoren 2 Sekunden Konfiguration des eingebauten Empf ngers Die Zentrale ist mit einem eingebauten Funkmodul f r den Empfang von Fernbedienungen mit festem Code und mit variablen Code mit einer Frequenz von 433 92MHz ausgestattet Um eine Fernbedienung verwenden zu k nnen muss diese zuerst erlernt werden die Speicherungsprozedur ist nachstehend beschrieben Das Ger t kann bis zu 14 unterschiedliche Codes speichern Speicherung eines neuen Sendeger ts mit Aktivierung der Schritt Schritt Funktion 1 Mal die Taste PGM 2 Sekunden lang dr cken die Leuchte D4 beginnt schnell zu blinken Innerhalb von 10 sec die Taste des Sendeger ts dr cken das mit der Schritt Schritt Funktion gespeichert werden soll Fernbedienungen aus dem Speicher l schen Zentrale stromlos machen Wieder Strom geben und gleichzeitig die Taste PGM 5 Sekunden lang gedr ckt halten die Leuchte D4 leuchtet fest und erlischt nach erfolgter L schung Taste PGM wieder loslassen nun ist der Spe
9. 336 MCE 93 68 MCE Wytyczna odno nie zdolno ci wsp dzia ania elektromagne tycznego 89 336 EWG 93 68 EWG Norme armonizzate applicate in particolare Applied harmonized standards in particular Angewendete harmonisierte Normen insbesondere Normes harmonis e utilis es notamment Normas armonizadas utilzadas particularmente Normy standard najcz ciej stosowane Direttiva sulla bassa tensione 73 23 CEE 93 68 CEE Low voltage guidelines 73 23 EEC 93 68 EEC Tiefe Spannung Richtlinie 73 23 EWG 93 68 EWG Directive bas voltage 73 23 CEE 93 68 CEE Reglamento de bajo Voltaje 73 23 MCE 93 68 MCE Wytyczna odno nie niskiego napi cia 73 23 EWG 93 68 EWG Norme armonizzate applicate in particolare Applied harmonized standards in particular Angewendete harmonisierte Normen insbesondere Normes harmonis e utilis es notamment Normas armonizadas utilzadas particularmente Normy standard najcz ciej stosowane EN 55022 EN 61000 3 2 EN 61000 3 3 EN 50082 1 EN 60204 1 EN 60335 1 Data Firma Data Firma BENINCA Automatismi Beninca SpA Via Capitello 45 36066 Sandrigo VI ITALIA
10. L8542336 CENTRALE DI COMANDO CONTROL UNIT STEUEREINHEIT CENTRALE DE COMMANDE CENTRAL DE MANDO CENTRALKA STEROWANIA MBE Libro istruzioni unac Operating instructions Betriebsanleitung Livret d instructions UNIONE NAZIONALE COSTRUTTORI Manual de instrucciones AUTOMATISMI PER CANCELLI PORTE Ksi eczka z instrukcjami SERRANDE ED AFFINI Dichiarazione CE di conformita EC declaration of confirmity EG Konformitatserklarung D claration CE de conformit Declaracion CE de conformidad Deklaracja UE o zgodno ci Con la presente dichiariamo che il nostro prodotto We hereby declare that our product Hiermit erklaren wir dass unser Produkt Nous d clarons par la pr sente que notre produit Por la presente declaramos que nuestro producto Niniejszym o wiadczamy e nasz produkt MBE e conforme alle seguenti disposizioni pertinenti complies with the following relevant provisions folgenden einschlagigen Bestimmungen entspricht correspond aux dispositions pertinentes suivantes satisface las disposiciones pertinentes siguientes zgodny jest z poni ej wyszczeg lnionymi rozporz dzeniami Direttiva sulla compatibilit elettromagnetica 89 336 CCE 93 68 CEE EMC guidelines 89 336 EEC 93 68 EEC EMV Richtlinie 89 336 EWG 93 68 EWG Directive EMV 89 336 CCE 93 68 CEE Compatibilit lectromagn tique Reglamento de compatibilidad electromagn tica 89
11. ampa zaczyna b yska 3 s przed rozpocz ciem pracy silnika Uwaga Po ka dej zmianie ustawie trymer w i Dip switch w od czy a nast pnie w czy zasilanie elektryczne Funkcje Trymer w TCA Pozwala na regulowanie czasu automatycznego zamykania Sprawdzi czy Dip Switch Nr5 ON Czas otwierania mo e by wyregulowany od min 1 s do maks 125 s TL Reguluje maksymalny czas operacji zamykania i otwierania Musi by ustawiony z dodaniem oko o 4 sekund do efektywnego czasu biegu urz dzenia Czas otwierania mo e by wyregulowany od min 5 s do maks 130 s Uwaga W przypadku niepe nego zamkni cia otwarcia bramy centralka oblicza czas pozosta y do sko czenia manewru w celu unikni cia niepotrzebnego przegrzania silnika TRAC Pozwala wyregulowa czas op nienia z jakim silnik MBE rozpoczyna operacj zamykania skrzyd a w odniesieniu do tej samej operacji dokonywanej przez silnik MB Czas mo e by wyregulowany od min 3 s do maks 30 s Czas op nienia w cyklu otwierania ustawiony jest na 2 sekundy Konfiguracja odbiornika wbudowanego Centralka wyposa ona jest w modu radio wbudowany kt rego celem jest odbieranie sygna w nadajnik w zar wnio na kod sta y jak i na kod zr nicowany na cz stotliwo 433 92MHz Przed przyst pieniem do u ywania nadajnika modu musi nauczy si jego odczytywania poni ej podana jest procedura zapisywania w pami ci urz dzenie mo e zapami ta dane do 14 r
12. atkowych 24Vac 0 5A max 10 11 ELS Po czenie zamka elektrycznego 12Vac 0 5A max 12 13 14 24 12 0 Po czenie wt rnego uzwojenia transformatora 15 16 17 POWER NT FT Potaczenie pierwotnego uzwojenia transformatora 18 19 Input 230Vac Wej cie 230Vac 50Hz 1 Faza 2 Zerowy 20 21 LAMP Wyj cie po czenia lampy ostrzegawczej 230Vac 40W max 22 23 24 Silnik MB Po czenie silnika MB bez centralki sterowania 22 bieg 23 bieg 24 wsp l 24 25 26 Silnik MB Po czenie silnika MB z centralk sterowania 24 wsp l 25 bieg 26 bieg Bramka przej cie dla Je eli b dzie u ywane przej cie dla pieszych nale y po czy pieszych przycisk normalnie otwarty N O mi dzy V wsp lny sterowania i ko eczkiem umieszczonym w pobli u zacisku STOP zobacz schemat Sprawdzanie po cze Po wyregulowaniu kra c wek mechanicznych tak jak to podano w instrukcji si ownika nale y post powa tak jak wskazano poni ej 1 Od czy zasilanie 2 Odsprz gli r cznie skrzyd a bramy przesun na pozycj do oko o po owy biegu a nast pnie zablokowa 3 W czy zasilanie 4 Przy pomocy przycisku lub pilota da polecenie przesuwu typu posuw posuw 5 Podczas fazy otwierania skrzyd a bramy powinny porusza si Gdyby tak si nie sta o nale y zamieni przewody biegu silnika 22 23 dla silnika MB i 25 26 dla silnika MBE 6 Wyregulowa czas i tryb dzia ania urz dzenia oraz moc silni
13. e Position 230V positioniert werden 8 Dip Schalter Funktionen DIP1 P P Mod W hlt die Betriebsart der Taste P P und des Sendeger ts Off Betrieb FFNEN gt STOPP gt SCHLIESSEN gt STOPP On Betrieb FFNEN gt SCHLIESSEN gt FFNEN DIP2 C A Aktiviert oder deaktiviert den automatischen SchlieBvorgang Off automatischer SchlieBvorgang deaktiviert On automatischer SchlieBvorgang aktiviert DIP3 Cond Aktiviert oder deaktiviert die Funktion Wohngemeinschaft Off Funktion Wohngemeinschaft deaktiviert On Funktion Wohngemeinschaft aktiviert Auf den ffnungsvorgang haben weder der Schritt Schritt Impuls noch der Impuls des Sendeger ts Einfluss DIP4 Prelam Aktiviert oder deaktiviert das Vorblinken Off Vorblinken deaktiviert On Vorblinken aktiviert Das Vorblinken beginnt 3 sec vor dem Einschalten des Motors Bemerkung Nach jeder nderung der Trimmer und Dip Schalter Einstellungen das Ger t stromlos machen und dann wieder an das Stromnetz anschlie en Trimmer Funktionen TCA Erm glicht es die Zeit des automatischen Schlie vorgangs einzustellen Kontrollieren ob Dip Schalter Nr 2 On Die Zeit kann zwischen 1 sec und maximal 125 sec eingestellt werden TL Stellt die maximale Zeit des ffnungs und Schlie vorgangs ein Die Zeit muss ungef hr 4 sec l nger sein als die die f r den tats chlichen Hub der Automatik ben tigt wird Die Zeit kann zwischen O sec und maximal 130
14. e le pr clignotement Off Pr clignotement invalid On Pr clignotement valid Le clignotant s active 3 s avant la mise en route du moteur Note Apr s toute modification des programmations des trimmers et des dip switches d brancher et rebrancher la fiche du r seau Fonction des Trimmers TCA Permet de r gler le temps de fermeture automatique V rifier le Dip Switch N 2 On Le r glage varie d un minimum de 1 s a un maximum de 125 s TL Regle la dur e maximum de la manceuvre d ouverture et de fermeture Il doit tre programm environ 4 sec en plus par rapport au temps de course effective de l automatisme Le r glage varie d un minimum de 5 s un maximum de 130 s Nota En cas d ouverture fermeture partielle la centrale calcule le temps qui reste pour l ach vement de la man uvre de mani re viter d inutiles surchauffes du moteur TRAC Permet de r gler le temps de retard avec lequel le moteur MBE commence la man uvre de fermeture par rapport au moteur MB Le r glage varie d un min de 3 s un max de 30 s En ouverture le temps de d calage des moteurs est de 2 secondes Configuration r cepteur incorpor La centrale dispose d un module radio incorpor pour la r ception des t l commandes soit code fixe soit code variable la fr quence de 433 92MHz Pour utiliser une t l commande il faut tout d abord l apprendre la proc dure de mise en m moire est illustr e ci de suite le dis
15. ellati FUNZIONI INGRESSI USCITE N Morsetti Funzione Descrizione 1 ANT Segnale Antenna 2 SHIELD Schermo Antenna 3 8 SCA Collegamento spia cancello aperto 24 Vac 3W max 4 Passo Passo Ingresso pulsante passo passo N O 5 STOP Ingresso pulsante STOP N C 6 FTC Ingresso collegamento dispositivi di sicurezza contatto N C ad es foto cellule 7 V Comune per tutti gli ingressi di comando 8 9 24 Vac Uscita alimentazione accessori 24Vac 0 5A max 10 11 ELS Collegamento elettroserratura 12Vac 0 5A max 12 13 14 24 12 0 Collegamento avvolgimento secondario trasformatore 15 16 17 POWER NT FT Collegamento avvolgimento primario trasformatore 18 19 Alimentazione Ingresso 230 Vac 50Hz 18 fase 19 neutro 20 21 LAMP Uscita collegamento lampeggiante 230Vac 40W max 22 23 24 Motore MB Collegamento al motore MB senza centrale di comando 22 marcia 23 marcia 24 com 24 25 26 Motore MBE Collegamento al motore MBE con centrale di comando 24 com 25 marcia 26 marcia Pedonale Se si desidera utilizzare l ingresso pedonale collegare un pulsante normal mente aperto N O tra V comune dei comandi ed il piolino posto vicino al morsetto STOP vedi schema Verifica collegamenti Dopo aver regolato i finecorsa come indicato nel manuale istruzioni dell attuatore procedere come segue 1 Togliere alimentazione 2 Sbloccare manualmente le ante portarle a circa met della corsa e ribloccarle 3 Ripr
16. hysically detached or adequately insulated by an additional insulation of at least 1 mm c The cables should be further fastened in proximity to the terminals d Check all connections before powering the unit e Check that settings of the Dip switches are the required ones f The N C inputs which are not in use should be short circuited INPUT OUTPUT FUNCTIONS Terminal No Function Description 1 ANT Antenna Signal 2 SHIELD Antenna Shield 3 8 SCA Indicator lamp Open gate 4 P P Input N O step by step push button 5 STOP Input N C STOP push button 6 FTC Input safety devices connection N C terminal e g photocells 7 V Common to all control inputs 8 9 24 Vac Output accessories power supply 24Vac 0 5 A max 10 11 ELS Electric lock connection 12Vac 0 5A max 12 13 14 24 12 0 Connection to transformer secondary winding 15 16 17 POWER NT FT Connection to transformer primary winding 18 19 Power supply Input 230Vac 50Hz 18 Phase 19 Neutral 20 21 LAMP Output flashing light connection 230Vac 40W max 22 23 24 MB Motor Connection to MB motor without control unit 22 movement 23 movement 24 com 24 25 26 MBE Motor Connection to MBE motor with control unit 24 com 25 mouvement 26 movement Pedestrian To use the pedestrian entrance connect the normally open N O push button between V control common and the little knob near terminal STOP see wire diagram
17. ic closure On enabled automatic closure DIP3 Cond The multi flat function is enabled or disabled Off disabled multi flat function On enabled multi flat function The P P Step by step impulse or the impulse of the transmitter have no effect in the opening phase DIP A Prelam Forewarning flashing light enabled or disabled Off disabled forewarning flashing light On enabled forewarning flashing light The flashing light is activated 3 s before the motor starts Note After modifying the setting of trimmers and Dip Switches switch off and power the unit again Functions of Trimmers TCA The automatic closure time can be adjusted with this trimmer Check Dip switch N 2 On This function can be adjusted between 1 s minimum and 125 s maximum TL The maximum time of the opening and closing phases can be adjusted with this trimmer Time should be preset approx 4 sec longer than the actual stroke time of the automatic system Adjustment ranges from 5 s minimum to 130 s maximum Note In the event of partial opening closing the control unit calculates the remaining time to complete the operation in order to avert useless overheating of the motor TRAC It allows to adjust the delay time with which motor MBE starts closing with respect to motor MB Adjustment range from 3 s minimum to 30 s maximum During opening the out of phase time of the motors is 2 seconds Configuration of the built in receiver The control unit is com
18. icher leer und die Leuchte D4 blinkt wieder wie blich BEMERKUNG Wenn die Speicherungsprozedur der Sendeger te abgerufen wird und die Leuchte D4 zwei Mal lang blinkt und dann erlischt bedeutet dies dass der Speicher des Empf ngers voll ist und das keine weiteren Sendegr te gespeichert werden k nnen Funktionen der LEUCHTEN LED D2 Leuchtet bei Stromversorgung LEDD4 Programmierung Funkempf nger LEDD5 Leuchtet bei Funksignalen auf der Frequenz des eingebauten Moduls Centrale de commande pour MBE La centrale lectronique MBE peut tre utilis e pour le contr le d un ou de deux moteurs MB MBE AVERTISSEMENTS GENERAUX a L installation lectrique et la logique de fonctionnement doivent tre conformes aux normes en vigueur b Les conducteurs alimentes avec tensions diff rentes doivent tre s par s physiquement ou ad quatement isol s avec une isolation suppl mentaire d au moins 1 mm c Les conducteurs doivent tre contraints par une fixation suppl mentaire proximit des bornes d Contr ler nouveau toutes les connexions faites avant de mettre sous tension e Contr ler que les programmations des Dip Switch sont celles d sir es f Les entr es N C non utilis es doivent tre fix es avec pontets FONCTIONS ENTREES SORTIES N Bornes Fonction Description 1 ANT Signal Antenne 2 SHIELD Blindage Antenne 3 8 SCA Connexion voyant portail
19. ilizzare un telecomando prima necessario apprenderlo la procedura di memorizzazione illustrata di seguito il dispositivo in grado di memorizzare fino a 14 codici diversi Memorizzazione di un nuovo trasmettitore con attivazione funzione P P Premere 1 volta il pulsante PGM per 2 secondi il led D4 inizia a lampeggiare velocemente Premere entro 10s il pulsante del trasmettitore che si desidera memorizzare con funzione P P Cancellazione dei telecomandi dalla memoria Togliere alimentazione alla centrale Ripristinare l alimentazione mantenendo premuto il pulsante PGM per 5 secondi il led D4 si accende a luce fissa e si spegne a cancellazione avvenuta Rilasciare il pulsante PGM la memoria stata cancella ed il LED D4 riprende a lampeggiare normalmente NOTA Se entrando nella procedura di memorizzazione dei trasmettitori il LED D4 emette due lampeggi lunghi e si spegne significa che la memoria della ricevente piena e non possibile memorizzare altri trasmettitori Funzioni LED LED D2 Acceso in presenza alimentazione di rete LED D4 Programmazione ricevitore radio LED D5 Si accende in presenza di segnali radio sulla frequenza del modulo incorporato MBE control unit The electronic control unit MBE can be used to control 1 or 2 motors MB MBE GENERAL WARNINGS a The wire connections and the operating logic should be in compliance with regulations in force b The cables featuring different voltage should be p
20. ire il suffira d inverser entre eux les fils de vitesse du moteur 22 23 pour le moteur MB e 25 26 pour le moteur MBE R gler alors les Temps et les Logiques de fonctionnement et de puissance du moteur Den 2 Reglage de la puissance moteur ATTENTION Ce r glage influe sur le degr de s curit de l automation V rifier que la force appliqu e sur le vantail est conforme aux normes en vigueur Sur le transformateur d alimentation il y a un connecteur Faston POWER qui permet le r glage de la puissance de moteurs sur 3 d f rents niveaux En pla ant le Faston POWER sur 120 on obtient la puissance mineure tandis que sur 190 on a la puissance majeure 10 ATTENTION L actionneur MB MBE n tant pas dot d un embrayage m canique r glable le faston POWER ne doit pas amp tre plac en position 230V Fonction Dip Switch DIP 1 P P Mod S lectionne le mode de fonctionnement de la Touche P P et de l metteur Off Fonctionnement OUVRE gt STOP gt FERME gt STOP gt On Fonctionnement OUVRE gt FERME gt OUVRE gt DIP2 C A Valide ou invalide la fermeture automatique Off fermeture automatique invalidee On fermeture automatique valid e DIP3 Cond Valide ou invalide la fonction copropriete Off Fonction copropriete invalidee On Fonction copropri t valid e L impulsion PP ou de l metteur n a aucun effet lors de la phase d ouverture DIP4 Prelam Valide ou invalid
21. istinare l alimentazione 4 Dare un comando di passo passo mediante pulsante o radiocomando 5 Le ante devono muoversi in apertura Nel caso ci non avvenisse sufficiente invertire tra loro i fili di marcia del motore 22 23 per il motore MB e 25 26 per il motore MBE 6 Procedere con la regolazione dei Tempi e delle Logiche di funzionamento e della potenza motore Regolazione della potenza motore ATTENZIONE Questa regolazione influisce sul grado di sicurezza dell automazione Verificare che la forza applicata sull anta sia conforme con quanto previsto dalle normative vigenti Sul trasformatore di alimentazione presente un connettore Faston POWER che permette la regolazione della potenza dei motori su 3 diversi livelli Posizionando il Faston POWER su 120 si ha la potenza minore spostandolo su 190 si ha la potenza maggio re ATTENZIONE Non essendo l attuatore MB MBE dotato di frizione meccanica regolabile il faston POWER non deve mai essere portato in posizione 230V Funzione Dip Switch DIP 1 P P Mod Seleziona la modalit di funzionamento del Pulsante P P e del trasmettitore Off Funzionamento APRE gt STOP gt CHIUDE gt STOP gt On Funzionamento APRE gt CHIUDE gt APRE gt DIP2 C A Abilita o disabilita la chiusura automatica Off chiusura automatica disabilitata On chiusura automatica abilitata DIP3 Cond Abilita o disabilita la funzione condominiale Off Funzione
22. istintas deben estar f sicamente separados o bien deben estar adecuadamente aislados con aislamiento suplementario de por lo menos 1 mm c Los conductores deben estar vinculados por una fijaci n suplementaria cerca de los bornes d Comprobar todas las conexiones efectuadas antes de dar la tensi n e Comprobar que las configuraciones de los Dip Switch sean las deseadas f Las entradas N C no utilizadas deben estar puenteadas FUNCIONES ENTRADAS SALIDAS N Bornes Funci n Descripci n 1 ANT Senal Antena 2 SHIELD Blindaje Antena 3 8 SCA Conexi n chivato cancela abierta 24 Vac 3W m x 4 P P Entrada bot n paso paso N A 5 STOP Entrada bot n STOP N C 6 FTC Entrada conexi n dispositivos de seguridad contacto N C por ej foto c lulas 7 V Com n para todas las entradas de control 8 9 24 Vac Salida alimentaci n accesorios 24Vac 0 5A m x 10 11 ELS Conexi n cerradura el ctrica 12Vac 0 5A m x 12 13 14 24 12 0 Conexi n bobinado secundario transformador 15 16 17 POWER NT FT Conexi n bobinado primario transformador 18 19 Input 230Vac Entrada 230Vac 50Hz 1 Fase 2 Neutro 20 21 LAMP Salida conexi n intermitente 230Vac 40W m x 22 23 24 Motor MB Conexionado con el MB sin central de control 22 marcha 23 marcha 24 com 24 25 26 Motor MBE Conexionado con el MBE con central de control 24 com 25 marcha 26 marcha Peatonal Si se desea utilizar la entrada peatones conectar un pu
23. itar in tiles recalentamientos del motor TRAC Permite ajustar el tiempo de retraso con el cual el motor MBE comienza la maniobra de cierre con respecto al motor MB La regulaci n var a entre un m n de 3 s y un m x de 30 s En apertura el tiempo de desfase de los motores es de 2 segundos Configuraci n receptor incorporado La central tiene un m dulo radio incorporado para la recepci n de mandos a distancia tanto con c digo fijo como con c digo variable con una frecuencia de 433 92 MHz Para utilizar un mando a distancia primero es necesario aprenderlo el procedimiento de memorizaci n es presentado a continuaci n el dispositivo puede memorizar hasta 14 c digos diferentes Memorizaci n de un nuevo transmisor con activaci n de la funci n P P Pulsar 1 vez el bot n PGM por 2 segundos el LED D4 empieza a parpadear r pidamente Pulsar dentro de 10s el bot n del transmisor que se desea memorizar con funci n PP Tachado de los mandos a distancia de la memoria Cortar la alimentaci n para la central Restablecer la alimentaci n manteniendo pulsado el bot n PGM durante 5 segundos el LED D4 se enciende con luz fija y se apaga una vez efectuado el tachado Soltar el bot n PGM la memoria ha sido tachada y el LED D4 vuelve a parpadear normalmente NOTA Si entrando en el procedimiento de memorizaci n de los transmisores el LED D4 emite dos parpadeos largos y se apaga significa que la memoria de la receptora est
24. ka Regulacja mocy silnika UWAGA Operacja ta wp ywa na stopie bezpiecze stwa urz dzenia automatyzacji Sprawdzi czy si a przy o ona do skrzyd a bramy zgodna jest z parametrami przewidzianymi przez obowi zuj ce normy Na transformatorze zasilania znajduje si prze cznik Faston POWER pozwalaj cy na wyregulowanie mocy silnik w na czterech r nych poziomach Po ustawieniu prze cznika POWER na 120 uzyskuje si najni sz moc przesuwaj c go na 190 otrzymuje si moc najwy sz 14 UWAGA Poniewa si ownik MB MBE nie jest wyposa ony w regulowane sprz g o mechaniczne nie nale y ustawia zacisku POWER w pozycji 230 V Funkcje Dip Switch w DIP1 P P Mod Wybiera tryb dzia ania przycisku P P posuw posuw i nadajnika Off Dzia anie w sekwencji OTWIERA gt STOP gt ZAMYKA gt STOP gt On Dzia anie w sekwencji OTWIERA gt ZAMYKA gt OTWIERA gt DIP2 C A Aktywuje lub wy cza funkcj automatycznego zamykania Off automatyczne zamykanie wy czone On automatyczne zamykanie w czone DIP3 U ytkownik Aktywuje lub wy cza funkcj u ytkownika Off Funkcja u ytkownika wy czona On Funkcja u ytkownika w czona Impuls przycisku P P lub nadajnika nie wp ywa na prac urz dzenia podczas fazy otwierania DIP4 Lamp ostrz Aktywuje lub wy cza funkcj ostrzegawczej lampy btyskajacej Off Lampa ostrzegawcza wy czona On Lampa ostrzegawcza w czona L
25. lsador normal mente abierto N A entre V com n de los comandos y el terminal situado cerca del borne STOP ver el esquema Comprobaci n de las conexiones Despu s de haber ajustado los finales de carrera tal y como indicado en el manual de instrucciones del actuador proceder como sigue 1 Cortar la alimentaci n 2 Desbloquear manualmente las hojas llevarlas a aproximadamente mitad de la carrera y bloquearlas de nuevo 3 Restablecer la alimentaci n 4 Dar un mando de paso paso mediante bot n o mando a distancia 5 Las hojas deben moverse en apertura En caso contrario basta invertir entre ellos los hilos de marcha del motor 22 23 para el motor MB y 25 26 para el motor MBB 6 Proceder con la regulaci n de los Tiempos y de las l gicas de funcionamiento y de la potencia motor Regulaci n de la potencia motor ATENCI N Esta regulaci n repercute en el grado de seguridad de la automatizaci n Comprobar que la fuerza aplicada sobre la hoja sea conforme con cuanto previsto por las normas vigentes En el transformador de alimentaci n hay presente un conector Faston POWER que permite la regulaci n de la potencia de los motores en 3 niveles distintos Poniendo el Faston POWER en 120 se tiene la potencia menor desplaz ndolo en 190 se tiene la potencia mayor ATENCI N Puesto que el actuador MB MBE no tiene embrague mec nico regulable el faston POWER no se debe poner nunca en posici n 230V
26. n Motor MBE mit Steuereinheit 24 com 25 Betrieb 26 Betrieb Fu g nger Will man den Fu g ngereingang verwenden die Taste N O zwischen V allgemein f r Steuerungen und der Sprosse in der N he der Klemme STOP siehe Plan anschlie en Anschl sse berpr fen Nachdem die Endschalter laut Anweisungen des Aktuatoren Handbuchs eingestellt worden sind folgenderma en vorgehen 1 Stromversorgung abtrennen 2 Von Hand die Torfl gel entsichern bis auf halbem Hub f hren und wieder blockieren Wieder Strom geben Einen Schritt Schritt Befehl ber die Taste oder die Fernsteuerung geben Die Torfl gel m ssen sich ffnen Anderenfalls die Leiter f r den Betrieb des Motors 22 23 f r den Motor MB und 25 26 f r den Motor MBE umkehren 6 Nun Zeiten Betriebslogik und Motorleistung einstellen Motorleistung einstellen ACHTUNG Diese Einstellung hat Einfluss auf die Sicherheit der Automatik Die f r das Tor angewendete Kraft muss den geltenden Vorschriften entsprechen Der Speisetrafo ist mit einem Faston POWER Verbinder versehen durch den die Motorleistung auf 3 verschiedene Stufen eingestellt werden kann Wird der Faston POWER Verbinder auf 120 eingestellt wird die Motorleistung auf das Minimum geregelt wird er auf 190 eingestellt wird die maximale Motorleistung erreicht ACHTUNG Da der Aktuator MB MBE nicht mit einer einstellbaren mechanischen Kupplung ausgestattet ist darf der Faston POWER niemals auf di
27. on und die Betriebslogik m ssen den geltenden Vorschriften entsprechen b Die Leiter die mit unterschiedlichen Spannungen gespeist werden m ssen physisch getrennt oder sachgerecht mit einer zus tzlichen Isolierung von mindestens 1 mm isoliert werden c Die Leiter m ssen in der N he der Klemmen zus tzlich befestigt werden d Alle Anschl sse nochmals pr fen bevor die Zentrale mit Strom versorgt wird e Kontrollieren ob die Dip Schalter richtig positioniert sind f Die nicht verwendeten N C Eing nge m ssen berbr ckt werden FUNKTIONEN EING NGE AUSG NGE Anzahl Funktion Beschreibung Klemmen 1 ANT Antennensignal 2 SHIELD Antennenabschrimung 3 8 SCA Anschluss Meldeleuchte Tor offen 24 Vac 3W max 4 P P Eingang Schritt Schritt Taste N O 5 STOP Eingang Taste STOP N C 6 FTC Eingang Anschluss Sicherheitsvorrichtungen Kontakt N C z B Fotozellen 7 V Allgemein f r alle Steuerungseingange 8 9 24 Vac Ausgang Speisung Zubeh r 24Vac 0 5A max 10 11 ELS Anschluss an das Elektroschloss 12Vac 0 5A max 12 13 14 24 12 0 Anschluss Wicklung sekund res Trafo 15 16 17 POWER NT FT Anschluss Wicklung prim res Trafo 18 19 Speisung Eingang 230Vac 50Hz 1 Phase 2 Nulleiter 20 21 LAMP Ausgang Anschluss Blinkleuchte 230Vac 40W max 22 23 24 Motor MB Anschluss an den Motor MB ohne Steuereinheit 22 Betrieb 23 Betrieb 24 com 24 25 26 Motor MBE Anschluss an de
28. plete with an incorporated radio receiver for both fixed code and variable code radio controls at 433 92MHz frequency To use a radio control its code should be copied first The memorization procedure is shown here under The device is able to store up to 14 different codes in memory Memorization of a new transmitter with activation of the P P step by step function Press PGM button once for 2 seconds the D4 LED starts flashing rapidly Within 10s press the transmitter push button which should be stored in memory with PP function To delete the control unit codes from memory Cut off power supply to the control unit Reset power supply by keeping the PGM button pressed for 5 seconds the D4 LED switches on with fixed light and then off when deletion is completed Release the PGM button memory is deleted and the D4 LED starts flashing regularly again NOTE If the D4 LED switches on with two long flashes and then switches off when entering the transmitter codes memorization mode this means that the receiver is full and no other transmitter code can be stored in memory LED functions LEDD2 Access when the unit is powered LED D4 Radio receiver programming LED D5 This LED switches on when radio signals are received on the built in module frequency Steuerung f r MBE Die elektronische Zentrale MBE kann zur Steuerung von 1 oder 2 Motoren MB MBE verwendet werden ALLGEMEINE HINWEISE a Die elektrische Installati
29. positif peut m moriser jusqu 14 codes diff rents La mise en m moire d un nouvel metteur avec activation de la fonction P P Appuyer 1 fois sur la touche PGM pendant 2 secondes le led D4 commence a clignoter rapidement Dans les 10 s appuyer sur la touche de l metteur que l on d sire m moriser avec fonction PP Effacement des t l commandes de la m moire Couper l alimentation la centrale Restaurer l alimentation en gardant le doit appuy sur la touche PGM pendant 5 secondes le led D4 s allume lumi re fixe sans clignoter et s teint une fois l effacement compl t Relacher la touche PGM la m moire a t effac e et le LED D4 reprend clignoter normalement NOTA Si une fois entr s dans la proc dure de mise en m moire des metteurs le LED D4 s teint apr s avoir mis deux clignotements longs cela signifie que la m moire du r cepteur est pleine et que l on peut plus m moriser d autres metteurs Fonctions LED LED D2 Branch en pr sence d une alimentation de r seau LED D4 Programmation r cepteur radio LED D5 S claire en pr sence de signaux radio sur la fr quence du module incorpor 11 Central por MBE La central electr nica MBE puede utilizarse para el control de 1 o 2 motores con MB MBE ADVERTENCIAS GENERALES a La instalaci n el ctrica y la l gica de funcionamiento deben cumplir las normas vigentes b Los conductores alimentados con tensiones d

Download Pdf Manuals

image

Related Search

Related Contents

InLine USB 3.0 Hub  i Université Laval Faculté des sciences de l`éducation Programme  Hitachi DH 25PB Power Hammer User Manual  取 扱 説 明 書 平行軸ギヤヘッド (GFS タイプ)  user manual  Setting Up Your VAIO Slimtop LCD Computer  User Manual  Samsung Apiradora SC6530 Manual de Usuario  Lire ce manuel avant d`installer le logiciel !  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file