1. MWS POGLEX Connect Le raccord universel pour pompes a chaleur piscine The universal connector for swimming pool heat pumps GUIDE D INSTALLATION INSTALLATION MANUAL Avertissement Veuillez lire attentivement ce manuel avant de proc der l installation du Poolex UConnect Ces instructions d installation font partie integrante du produit Elles doivent tre remises l installateur et conserv es par l utilisateur En cas de perte du manuel veuillez vous r f rer au site www poolex fr Les indications et avertissements contenus dans le present manuel doivent tre lus avec attention et compris car ils fournissent d importantes informations concernant la manipulation et le fonctionnement de la pompe en toute s curit Conservez ce manuel dans un endroit accessible afin de faciliter les futures consultations L installation doit tre effectu e par un professionnel qualifi conform ment aux r glementations en vigueur et aux instructions du fabricant Une erreur d installation peut entrainer des blessures physiques aux personnes ou aux animaux ainsi que des dommages m caniques pour lesquels le fabricant ne peut en aucun cas tre tenu res ponsable Apr s avoir d ball la pompe veuillez v rifier le contenu afin de signaler tout dommage ventuel Avant de brancher la pompe assurez vous que les donn es fournies sont compatibles avec les conditions d installation r elles et ne d passent
2. associ s indique qu il ne doit pas tre jet avec les ordures m nag res courantes l issue de sa dur e de vie S parez cet appareil des autres d chets pour ne pas nuire a l environnement et a la sant des personnes par une limination non contr l e des d chets EE Recyclez l appareil pour encourager la r cup ration durable des ressources mat rielles Les utilisateurs priv s peuvent contacter le vendeur aupr s duquel ils ont achet le produit ou les autorit s comp tentes pour savoir comment recycler l appareil de mani re respectueuse de l envi ronnement Les utilisateurs professionnels doivent s adresser a leurs fournisseurs et consulter les conditions qui figurent dans le contrat de vente Please make sure to read this installation manual thoroughly before ins talling your Poolex UConnect These instructions are an integral part of the product They must be given to the Installer and kept by the end user In case of loss of this manual please refer to our website www poolex fr The indications and warnings contained in this manual must be read and understood as they give important information concerning the handling and the safe functioning of the pump Please keep this manual in a safe place in order to facilitate future use The installation must be made by a qualified professional according to the current legal requirements and the manufacturer s instructions A poorly installed Connec tor may lead to bodily ha
3. mitee des tuyaux Q puis raccordez les a la pompe a chaleur en veillant a ne pas inverser l entr e et la sortie d eau Installation TAPE 7 Fixez la poign e sur le dessus du bo tier l aide des vis fournis A Attention l tape suivante doit tre r alis e par un professionnel qualifi L lectricit doit tre coup e avant toute intervention TAPE 8 Apr s avoir coup l alimentation lectrique connectez le transformateur E a votre pompe a chaleur ou directement a votre installation lectrique selon si vous souhaitez que le kit Poolex UConnect soit asservie a votre pompe a chaleur Pour un fonctionnement par asservissement reportez vous a la notice d installation de votre pompe a chaleur Finalisez l installation en reliant le cable lectrique du Poo lex UConnect au transformateur L installation est termin e votre Poolex UConnect doit maintenant fonctionner Maintenance HIVERNAGE En hiver lorsque la temp rature ambiante descend en dessous de 3 C ou lors d un arr t prolong de la pompe il est indispensable de proc der a l hivernage de votre kit Poolex UConnect La proc dure est simple D branchez le bo tier d alimentation Deconnectez et vidangez les tuyaux Retirez le boitier UConnect de l eau Rangez votre kit Poolex UConnect a l abris des intemp ries en prenant soin d obstruer l entr e et la sortie d eau m IS GARANTIE Poolstar garantit au
4. pas les limites maximales auto ris es pour le produit en question En cas de d faut et ou de dysfonctionnement de la pompe l alimentation lectrique doit tre isol e et aucune tentative de r paration de la panne ne doit tre entreprise Les travaux de r paration ne doivent tre effectu s que par un service d assistance tech nique agree en utilisant des pieces d tach es originales Le non respect des clauses pr cit es peut avoir une influence n gative sur le fonctionnement en toute s curit de la pompe Pour garantir l efficacit et le bon fonctionnement de la pompe il est important de veiller ce quelle soit r guli rement entretenue conform ment aux instructions fournies Le bo tier d alimentation transformateur 230 12V doit tre plac l cart de votre pis cine et hors de port e de vos enfants selon les normes lectriques en vigueur Le kit Poolex UConnect ne doit pas rest immerg dans la piscine lors d un traitement choc de l eau Le kit Poolex UConnect est exclusivement con u pour une utilisation en piscine Toutes les autres utilisations doivent tre consid r es comme inappropri es incor rectes voire dangereuses dit en Avril 2014 par POOLSTAR FRANCE Descriptif amp Contenu MW SM POOLEX connect Poolex UConnect La solution la plus rapide et la plus simple pour raccorder votre pompe a chaleur a votre bassin CARACT RISTIQUES Dimensions en mm Alime
5. propri taire d origine les d fauts mat riels et les d fauts de fabrication du kit Poolex UConnect pendant une dur e de 2 ans compter de la date de facturation du premier utilisateur La garantie ne s applique pas dans les cas suivants e Dysfonctionnement ou dommage r sultant d une installation d une utilisation ou d une r paration non conforme aux consignes de s curit e Dysfonctionnement ou dommage r sultant d un milieu chimique impropre de la piscine e Dysfonctionnement ou dommage r sultant de conditions impropres a la destination d usage de l appareil Dommage r sultant d une n gligence d un accident ou de cas de force majeure e Dysfonctionnement ou dommage r sultant de l utilisation d accessoires non autoris s Les r parations prises en charges pendant la p riode de garantie doivent tre approuv es avant leur r ali sation et confi es a un technicien agr La garantie est caduque en cas de r paration de l appareil par une personne non autoris e par la soci t Poolstar Les pi ces garanties seront remplac es ou r par es a la discr tion de Poolstar Les pieces d fectueuses doivent tre retourn es a Poolstar pendant la p riode de garantie pour tre prises en charge La garantie ne couvre pas les frais de main d oeuvre ou de remplacement non autoris s Le retour de la pi ce d fectueuse n est pas pris en charge par la garantie RECYCLAGE Le symbole figurant sur ce produit et les documents
6. e pipes O then connect them to the heat pump making sure not to reverse the water entrance and exit Installation STEP 7 Install the handle on top of the body of Poolex UConnect using the supplied screws WARNING THE FOLLOWING STEP MUST BE MADE BY A QUALIFIED PROFES SIONAL WITH THE ELECTRICITY SHUT OFF BEFORE ALL INTERVENTION STEP 8 After having shut off the electricity connect the transformer E to your heat pump or directly to your electrical installa tion depending on whether you wish Poolex UConnect to be linked to your heat pump In this case please refer to your heat pump manual Finalize the installation by linking the Poolex UConnect electric cable to the transformer The installation is now finished and your Poolex UConnect is ready to function Maintenance WINTERIZING In winter when the air temperature goes below 37 F 3 C or during a lengthy period of not using the device it is crucial that you winterize your Poolex UConnect Kit Follow this simple procedure Unplug the power adaptor Disconnect and drain the pipes Take the Poolex UConnect box outside of water Put your Poolex UConnect kit away sheltered from inclement weather making sure that the water entrance and exit are blocked mn IS WARRANTY Poolstar warranties to the original owner all material defects and manufacturing defects of the Poolex UConnect kit for two years following the billing date of the
7. first user Warranty is not extended in the following cases e Malfunction or damages resulting from the installation use or repair not conform to security instructions e Malfunction or damages resulting from improper pool chemicals e Malfunction or damages resulting from improper conditions of use e Damage resulting from carelessness an accident or acts of God e Malfunction of damages resulting from the use of non authorized accessories Any repairs under Warranty must be approved before they are made and must be handled by a certified technician The Warranty is cancelled if repairs are made by a person non authorized by Poolstar The warrantied parts will be replaced or repaired at Poolstar s discretion Defective parts must be returned to Poolstar within the Warranty period The Warranty does not cover unauthorized costs of labor or part replacements Shipping cost of the defective part is not included in the Warranty RECYCLING The symbol on these products and associated documents indicates that it cannot be disposed of with household trash at the end of its lifecycle Please separate this product from other waste not to harm the environment or people s health Recycle the device to encourage the durable recovery of material resources Private users may EE Contact the vendor from whom they bought the product or the competent authorities to learn how to recycle the device being respectful to the environment Professional users
8. must contact their supplier and consult the contract conditions POGLEX www poolex fr ASSISTANCE TECHNIQUE SUPPORT 0 826 102 852 Zr Poolstar CE L art de vivre ma piscine Distribution POOLSTAR FRANCE www poolstar fr ZA les Pielettes 13740 LE ROVE FRANCE
9. ntation 230V Moteur pompe 12V 85W Protection IPX8 D bit min 3 8 m h D bit max 5 2 m h Connecteur 1 CONTENU X2 X2 Raccords PAC UC Adaptateur PAC 1 Joint d tanch it Joint d tanch it longueur 6m 30mm Y 30mm 38mm Y 30mm Y 38mm Transformateur Poolex UConnect Poign e amovible Kit de fixation AC 230V AC 12V Fusible 1A et son cable d alimentation 8m Installation TAPE 1 Installation du kit de fixation Fixez la plaque metalique sous le bo tier Poolex UConnect l aide des 3 vis de fixations fournies TAPE 2 Placez le kit Poolex UConnect F au bord de votre piscine La partie inf rieure doit tre immerg e jusqu hauteur de la buse de refoulement Assurez vous d tre a moins de 4 m tres de votre pompe chaleur TA nuas W Y TAPE 3 Pour plus de stabilit le Poolex UConnect peut tre fix au bord de votre piscine a l aide de deux vis fix es de chaque cote de la partie sup rieure Installation TAPE 4 Placez les joints d tanch it s l extr amp mites des rac cords puis vissez les au boitier ETAPE 5 Placez les joints d tanch it s sur la partie large des adaptateurs a puis vissez ces adaptateurs sur l entr e et la sortie de votre pompe a chaleur Selon le modele de votre pompe a chaleur un adaptateur supplementaire peut tre requis ETAPE 6 Enfin placez les joints d tanch it s l extr amp
10. rm to people or animals as well as to mechanical damages for which the manufacturer may not be held responsible After having taken the UConnect out of its packaging please check it thoroughly in order to detect any possible damage Before plugging the Connector please insure that the provided data is compatible with the actual installation process and that actual conditions do not surpass the maximum authorized limits In case of product defect or dysfunction the electrical connection must be isola ted and no attempt to repair the dysfunction or breakdown Repair work must be made by an authorized technical assistance service only by using original spare parts The non respect of these conditions may have a negative impact on the safe functioning of the pump To guarantee the efficiency and the proper functioning of the pump it is important to make sure that it is properly and regularly maintained according to instructions The power adaptor 230 12V transformer must be placed away from your swimming pool and not be near children according to current electric norms The Poolex UConnect kit must not remain in the pool during intensive pool water treat ment The Poolex UConnect kit is exclusively for use in swimming pools All other uses must be considered inappropriate and dangerous Published in April 2014 by POOLSTAR FRANCE Description amp Content MW OM POOLEX connect Poolex UConnect The fastest and ea
11. siest solution to connect your heat pump to your swimming pool F EATU RES Inch dimensions Power Supply 230V Warter Pump 12V 85W IPX8 Protection Min water flow 3 8 m h 836 gal hr Max water flow 5 2 m h 1 144 gal hr 1 Adaptor Heat pump connector Heat pump adapter 1 Seal Seal 6yd cable 6m Y 1 2 30mm 1 2 1 5 30mm 38mm 1 2 30mm 1 5 38mm Power adapter Poolex UConnect Removable handle Mounting kit AC 230V AC 12V Fusible 1A with a 8yd m cable 8m Installation STEP 1 Installation of the fixation device Place the metallic plate under the Poolex UConnect body F with the 3 supplied screws STEP 2 Place the Poolex UConnect on the side of your swim ming pool The bottom part must be immersed up to the delivery nozzle Make sure to be at least 4 yards away from your heat pump TA nuas W Y STEP 3 For better stability the Poolex Uconnect may be attached to the side of your pool with 2 screws placed on each side of the upper part Installation STEP 4 Place the waterproofing seals at the end of each connec tor then screw them to the body of the connector STEP 5 Place the waterproofing seals on the large side of the adaptors O then screw these adaptors on the entrance and the exit of your heat pump According to the heat pump you may need an additional adaptor STEP 6 Then place the waterproofing seals at the end of th
Download Pdf Manuals
Related Search
Related Contents
Notice Topcom Multifunctional body scale iPORT NTx-GigE External Frame Grabber User Guide LR1 エネルギー CM2428E TEXT Mode d`emploi Suunto 110.9772 User's Manual Instructions d`utilisation Edital - Tribunal Regional Eleitoral de Santa Catarina Lightolier IS-A1 User's Manual Copyright © All rights reserved.