Home
Microscopes Microscopes
Contents
1. S B 387 901 044 Siret 387 901 04400017 Direct connection for technical support A team of experts at your disposal from Monday to Friday opening hours You re looking for technical information You wish advice for use You need an urgent diagnosis We take in charge your request immediatly to provide you with the right answers regarding your activity field Biology Physics Chemistry Technology Free service 33 0 2 32 29 40 50 Call cost not included
2. parts of the microscope In order to ensure a dust free prism never remove the eyepieces Never touch the lenses If dust has entered the objective return it to us for cleaning Before transport pack the microscope and its accessories 8 After sales service The device is under a 2 year guarantee it must be sent back to our workshops For any repairs adjustments or spare parts please contact JEULIN TECHNICAL SUPPORT Rue Jacques Monod BP 1900 27 019 EVREUX CEDEX FRANCE 33 0 2 32 29 40 50 ENGLISH 8 7 Assistance technique en direct Une quipe d experts a votre disposition du Lundi au Vendredi 8h30 a 17h30 Vous recherchez une information technique Vous souhaitez un conseil d utilisation Vous avez besoin d un diagnostic urgent Nous prenons en charge imm diatement votre appel pour vous apporter une r ponse adapt e votre domaine d exp rimentation Sciences de la Vie et de la Terre Physique Chimie Technologie Service gratuit 33 0 2 32 29 40 50 Hors co t d appel www jeulin fr Aide en ligne Rubrique FAQ seu in Rue Jacques Monod Z I n 1 Netreville BP 1900 27019 Evreux cedex France T l og 33 0 2 32 29 40 00 Fax 33 0 2 32 29 43 99 Internet www jeulin fr support jeulin fr Phone 33 0 2 32 29 40 49 Fax BIS 33 0 2 32 29 43 05 Internet www jeulin com export jeulin fr SA capital 3 233 762 Siren R C
3. Microscopes Microscopes a clairage par miroir Microscopes Mirror illumination Ref 571 141 571 142 Microscope P C B grand champ ass Wide field P C B microscope English p 5 Version 7001 Microscopes J e U L Nn Microscope P C B grand champ Ref 571 141 571 142 Mod le repr sent LM900 Grand Champ R f 571142 FRAN AIS Microscopes Microscope P C B grand champ Ref 571 141 571 142 FRANCAIS 1 Description Statif robuste et stable inclinable a 90 Platine ronde 120 mm tournante sur 360 centrable avec blocage en position valets Dispositif de centrage de la platine par deux boutons lat raux Tourelle revolver pour 3 objectifs Tube optique de longueur 170 mm Oculaires Huyghens X 6 et X 15 et grand champ x 10 Objectifs achromatiques au diam tre international 20 mm 4 x ON 0 10 10 x ON 0 25 40 x r tractable ON 0 65 Objectifs achromatiques au diam tre international 20 mm 4 x ON 0 10 10 x ON 0 25 60 x r tractable ON 0 85 Porte filtre disque bleu Poids du microscope Les microscopes sont livr s en coffret polystyr ne avec notice JeEuULIN Mod les concern s Type PCB LM 900 R f 571 141 R f 571 142 bx EX LAN bx bx EA LAN LAN LAN D4 NF EA ZA p4 NF x p4 p4 ZA ZA NF ZA ZA 4 000 kg 4 300 Kg 2 Caract ristiques techniques e Grossissements Oculaires Huyghens H Objecti
4. fs achromatiques Grand Champ WF 40 X ou 60 X 240 ou 360 aa 60 10 x WF 400 ou 600 600 ou 900 grocer P C B grand champ J e U L Nn Ref 571 141 571 142 3 Mode d emploi 3 1 Dispositif d clairage Les microscopes PCB sont quip s d un miroir plan concave avec lyre orientable selon deux plans perpendiculaires La source de lumi re pourra tre e soit naturelle lumi re du jour en vitant d utiliser directement les rayons du soleil e soit artificielle par exemple la lampe individuelle R f 574 169 Pour des travaux plus importants nous vous conseillons l utilisation de la lampe enfichable la place du miroir description au chapitre ACCESSOIRES 3 2 Observation en lumi re naturelle miroir ou lampe La pr paration plac e sur la platine est maintenue par deux valets Commencer l observation avec un objectif de faible grossissement 4 x ou 10x Diriger le faisceau lumineux sur la pr paration en r glant l orientation du miroir Doser l intensit de lumi re en r glant l ouverture du diaphragme de mani re obtenir le meilleur contraste Faire la mise au point rapide en man uvrant la vis de r glage de la cr maill re Parfaire ventuellement cette mise au point l aide de la vis microm trique Pour passer au grossissement sup rieur tourner simplement la tourelle pour amener l objectif d sir au dessus de la pr paration Faire la mise au point en agissant u
5. niquement sur la vis microm trique N B Les objectifs 4 x et 10 x peuvent tre employ s pour l examen d une pr paration sans lamelle couvre objet Ces objectifs permettent aussi l observation en lumi re r fl chie Les conditions d clairement sont tr s d pendantes de la position du condenseur penser la r gler pour obtenir l homog n it du champ en l absence de pr paration 4 Accessoires non livr s avec les microscopes 4 1 Dispositif d clairage Lampe enfichable avec prise de terre R f 574 169 220 Volts 4 2 Observation en lumi re polaris e Pour des observations plus pr cises utilisez la PLATINE POLARISANTE R f 574 174 qui vous donnera les meilleurs r sultats FRAN AIS 3 7 grocer P C B grand champ J e U L Nn Ref 571 141 571 142 5 Observation avec une cam ra Utiliser l oculaire grand champ x 10 livr avec le microscope Pour plus de d tails vous reporter la notice livr e avec les cam ras 6 Pi ces de rechange Miroir avec lyre R f 574 190 Oculaires et objectifs consultez le catalogue JEULIN 7 Maintenance Le microscope doit tre conserv l abri de la poussi re et des chocs ventuels Quand il n est pas en service le ranger dans sa bo te ou le couvrir d une housse Les parties m talliques du microscope doivent tre nettoy es r guli rement avec un chiffon doux impr gn de vaseline sans acide Au besoin nettoyer avec de l essence avant de graisse
6. o move to a higher magnification just turn the turrret to bring the desired objective above the sample Focus by only using the micrometer screw Note The objectives 4 x and 10 x can be used for observing a sample without cover glass These objectives are also suitable for observation in reflected light Lighting conditions depend greatly on the position of the condenser remember to adjust it without the sample to obtain a uniform field 4 Accessories not delivered with the microscopes 4 1 Lighting device Plug in lamp with earth plug Ref 574 169 220 Volts 4 2 Observation in polarised light For more accurate observations use the POLARISING STAGE Ref 574 174 which will give you best results ENGLISH Mi gt Wide field P C B microscope J e U L Nn Ref 571 141 571 142 5 Observation with cameras Use the wide field eyepiece x 10 delivered with the microscope For more details refer manual delivered with the cameras 6 Spare parts Mirror with harp Ref 574 190 Eyepieces and objectives Refer JEULIN catalogue 7 Maintenance The microscope must be kept away from dust and from possible shocks When not in use keep it in the box or cover it with the help of a dust cover The metal parts of the microscope must be cleaned regularly with a soft cloth soaked in acid free Vaseline If required clean with spirit before lubricating During cleaning and lubricating take care not to dirty the optical
7. r Pendant ces op rations de nettoyage et de graissage prendre soin de ne pas clabousser les parties optiques du microscope Pour prot ger de la poussi re le prisme du tube optique laisser en permanence l oculaire Ne jamais poser les doigts sur les lentilles Si la poussi re a p n tr l int rieur de l objectif nous retourner celui ci pour le nettoyage Avant de transport emballer le microscope et ses accessoires 8 Service apr s vente La garantie est de 2 ans le mat riel doit tre retourn dans nos ateliers Pour toutes r parations r glages ou pi ces d tach es veuillez contacter JEULIN SUPPORT TECHNIQUE Rue Jacques Monod BP 1900 27 019 EVREUX CEDEX FRANCE 33 0 2 32 29 40 50 FRAN AIS 4 7 Microscopes Wide field P C B microscope J e U L Nn Ref 571 141 571 142 Model shown LM900 Wide field Ref 571142 ENGLISH Microscopes Wide field P C B microscope J e U L Nn Ref 571 141 571 142 ENGLISH 1 Description Concerned models PCB Type LM 900 Ref 571 141 Ref 571 142 Robust and stable stand inclinable through 90 centrable with fixing clamp Stage centering device consisting of 2 side knobs W W Optical tube lenght of 170 mm tC CU W K K Achromatic objectives with international diameter of 20 Ka CAS N 7 mm 4 x NA 0 10 10 x NA 0 25 40 x retractable NA 0 65 Achromatic objectives wi
8. th international diameter of 20 mm 4 x NA 0 10 10 x NA 0 25 60 x retractable NA 0 85 NI p4 EAS ANA p4 D4 NZ ZAN 4 000 kg The microscopes are delivered in polystyrene boxes with the manual ZANI AINAN a ZAN A CO op o A 2 Technical features e Magnifications Huyghens eyepiece H Wide field WF 6x H 24 60 2400r860 60o 150 6000r900 10 x WF Mi gt Wide field P C B microscope J e U L Nn Ref 571 141 571 142 3 Operating instructions 3 1 Lighting device The PCB microscopes are fitted with a plane concave mirror with harp adjustable on two perpendicular planes The light source could be e Either natural day light but preferably not direct rays from the sun e or artificial for example an individual lamp Ref 574 169 For longer viewing we recommend the use of the plug in lamp instead of the miror description given in ACCESSORIES 3 2 Observation in natural light mirror or lamp The sample placed on the stage plate is held by two clamps Start the observation with an objective of small magnification 4 x or 10 x Direct the light beam on the sample by adjusting the direction of the mirror Vary the light intensity by adjusting the diaphragm so as to obtain the best contrast Do a rapid focus by using the adjusting screw of the rack If required bring the focus to perfection with the help of the micrometer screw T
Download Pdf Manuals
Related Search
Related Contents
加湿・保湿庫 - のトーリ・ハン LED LAMP WITH BLUETOOTH SPEAKER USER MANUAL Manual de Instalação SIROCCO Português be quiet! Dark Rock TF Axis 360 Administrator User Manual Camaraderie n°276 - Fédération Nationale des Francas KeepOut R1 Wegener Communications 6420 User's Manual Copyright © All rights reserved.
Failed to retrieve file