Home

VF-MB1 / S15 通信オプション 注意事項説明書

image

Contents

1. 1 EEPROM Dl 10 10 2 MIRE AIC DUVC CBR i HEBE
2. v OFF V ATE V H
3. V V Y 15 E6581 739 EZOZ LED eR
4. 1 2 1 2 S 1 2 3 4 4 DeviceNetrW ODVA Open DeviceNet Vendor Association Inc PROFIBUS PROFIBUS Nutzerorganization EtherNet IPTM ControlNet International Ltd Modbus l amp Schneider Automation Et
5. IPEOO32 aR 7 DY 5 t wi ek PROFIBUS DeviceNet CC Link DP VO V 1 Type AC V1 1 1 B56 V2 O 1 Telegram Instance 2 PROF Idrive 20 70 21 71 3 Vendor Spec 4 Vendor Spec fate LRUN LERR SD RD ST DX E6581897 E6581896 E6581829 VEMBT S18 AT o ALED MS NS VF MB1 S15 1 1100 130 130QO CC Link V1 OO EtherNet IP 2 Ue AO CoE CANopen CiA Instance 402 V3 drive 20 70 21 71 1 7h 2Bh profile 4 Vendor Spec 65 O RUN L A X1 LED LNK NS MS LNK 2 INDX A LSE EtherNet IP Modbus TCP
6. 5 00 Communication Instance Support Code specification 20 70 21771 03h 06h 10h etc 17h 2Bh 4 Vendor Spec Status LED Warranty Any part of the communication options that are proved to be defective will be repaired and adjusted free of charge under the following conditions 1 This warranty applies only to the option unit 2 Any part of the option which fails or is damaged under normal use within twelve months from the date of delivery shall be repaired free of charge 3 For the following kinds of failure or damage the repair cost shall be borne by the customer even within the warranty period i Failure or damage caused by improper or incorrect use or handling or unauthorized repair or modification of the option ii Failure or damage caused by falling or an accident during transportation after the purchase iii Failure or damage caused by fire salty water or wind corrosive gas earthquake storm or flood lightning abnormal voltage supply or other natural disasters iv Failure or damage caused by the use of the inverter for any purpose or application other than the intended one 4 All expenses incurred by Toshiba for on site services shall be charged to the customer unless a service contract is signed beforehand between the customer and Toshiba in which case the service contract has priority over this warranty DeviceNet is a trademark of Open DeviceNet Vendor Association Inc ODVA PROFIBUS is a
7. Set up Communication error trip function i 10 HY to stop the Inverter when the option unit is deactivated by an unusual event such as tripping an operating error power outage failure etc E Limitation of use A Warning e Never use the option with any device other than applicable TOSVERT series inverters Qe This will result in accident eae U in general ve oy prohibited O 0 action TTF Never disassemble modify or repair the option This can result in electric shock fire or injury For repairs call your sales distributor Do not put or insert any kind of objects into the option electrical wire cuttings rods wires etc This can result in electric shock or fire Do not splash water or any other fluid over the option do not touch the option with wet hands This can result in electric shock or fire Do not apply shock falling etc on the option This can result in damage or malfunction Do not touch the connector to inverter refer to the Part names drawing This can result in malfunction or accident Turn off the power immediately in case of abnormalities such as smoke abnormal odor noise or blind display Neglect of these conditions can result in fire For repairs call your sales distributor Operate under the environmental conditions prescribed in this manual Operations under any other condition can result in malfunction E Disposal e If you dispose of the option
8. registered trademark of PROFIBUS Nutzerorganization EV EtherNet IP is a trademark of ControlNet International Ltd Modbus is a registered trademark of Schneider Automation EtherCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany CC Link is a registered trademark of Mitsubishi Electric Corporation
9. TOSHIBA VF MB1 S15 1 2 3
10. have it done by a specialist in industrial waste disposal Improper disposal can lead to explosion of noxious gases resulting in accident Persons who specialize in the processing of waste and known as Industrial Waste Product Collectors and Transporters or Industrial Waste Disposal Persons If the collection transport and disposal of industrial waste are done by someone who is not licensed for that job it is a punishable violation of the law Laws in regard to cleaning and processing of waste materials Prohibited E Wiring Installation De installation Do not use the option if it is damaged or any part of it is missing Operating the defective product can result in electric shock or fire For repairs call your sales distributor Do not connect any communication device other than applicable device to the option This can result in malfunction or accident Do not pull the cable and the connector connected to the option This can result in damage or malfunction Do not touch the sharp parts of the option and the inverter This can result in injury The following steps must be performed before wiring and installation de installation Turn off all input power wait at least 15 minutes and confirm that the charge lamp of inverter is no longer lit If steps above are not properly performed this can result in electric shock Use an emergency stop device and an additional safety device in your system to prevent se
11. herCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany 2332 00 CC Link O1A Fam TOSHIBA VF MB1 S15 communication option Precautions Manual Notice 1 Make sure that this instruction manual is delivered to the end user of communication option 2 Read this manual before installing or operating the option Keep it in a safe place for reference 3 All information contained in this manual will be changed without notice Please contact your Toshiba distributor to confirm the latest information Safety Precautions There is important information on the inverter and in its instruction manual for proper use of the device to prevent injury to users or damage to property Read the instruction manual attached to the inverter to understand the safety precautions the symbols and indications completely Please observe the contents of these manuals at all times For detailed functions and operation of this unit please refer to the inverter s instruction manual and each communication function manuals If the communication function manual is necessary please contact our branch offices or sales offices 1 The life of EEPROM is approximately 100 000 times Avoid writing a command more than 100 000 times to the same parameter of the drive and the option module 2
12. rious accident due to the option malfunctions Usage without any emergency stop device or any additional safety device can result in accident or injury Prohibited Mandatory action E6581 739 Application Notes m Part names Connector to inverter Status LED Tab for release Connector for network The option above is IPE003Z The other options have different connectors for network Product Specification Item Type form PROFIBUS DeviceNet CC Link DP VO V1 Type AC drive V1 1 occupies one station V2 0 occupies one station selectable from among double quadruple and octuple Instance 20 70 21 71 Vendor 4 Vendor Spec Telegram 1 4 PROF Idrive 3 Spec Communication specification Station type Remote device station Terminating resistor Nothing 110 i Environment In accordance with applicable inverter 1 Need connect a 110 ohm or 130 ohm resistor 130 ohm is a resistance value for the CC Link Ver 1 00 dedicated high performance cable IPE002Z IPE003Z RJ45 x 2 EtherNet IP 2 Modbus TCP 2 EtherCAT Type AC drive Supports the CoE only Supports CANopen CiA 402 V3 drive profile Configuration system on Web RUN LA X1 LNK NS MS LNK ERR X2 UA E6581741 E6581818 Applicable model VF MB1 S15 Terminating resistor Nothing In accordance with applicable inverter 2 Select the protocol EtherNet IP or Modbus TCP by parameter