自動絞り付きバリフォーカルレンズ 取扱説明書
Contents
1. E CS C C C S 1 1 gt
2. A E
3. ND 1 0 m TELE FAR BCE CE EU EMC EN50130 4 EN55022 E m
4. 320 HOYA PENTAX 2 36 9 174 8639 Tel 03 3960 0336 Fax 03 3960 0337 3170509 Z2 2 J S3095046 E 1 3 CS 5mm 50mm F1 8 F360 0 6m 1900 10 20 C 700Q 10 20 C 4V 0 5V 20 C 50 C PENTAX Auto Iris Vari Focal Lens Operating Instructions E Model number TS10V518AED Thank you for choosing PENTAX CCTV lenses Before operating this lens please read these instructions carefully After reading this Operating Instructions keep it for future reference E For your safety on use of a lens Before operating pay special attention to the following remarks A CAUTION This alerts users to the possible risk of personal and material
5. O E DC JEITA EIAJ RC 5204 1 G 2 s _ 3 4 E PITYE DC C S
6. 4V or less Close to Open Over 0 5V Open to Close Driving voltage Temperature range 20 C 50 C
7. harm A WARNING This alerts users to the possible risk of personal harm S This is a warning to users A This is to caution users A WARNING Do not look at the sun through the lens with the naked eye Loss of eyesight may occur Do not disassemble repair or modify the lens Fire electric shocks or malfunction may occur If the lens emits smoke smells of smoke or gives off heat discontinue use immediately Fire or electric shocks may occur Do not damage bend twist or pull on the cable Fire electric shocks or malfunction may occur 1 1 A CAUTION Do not leave unused lenses in direct sunlight Fire may occur Mount the lens firmly on a camera so that it will not loosen Do not install the lens in a place where vibration and shock are expected It may come loose and fall off A and fall off A E Precautions Do not use organic solvents such as thinners alcohol or benzine to remove stains from the lens Use a blower or a clean lens brush to remove dust When grease or fingerprints are on the lens wipe them off with a lens cleaning paper and lens cleaner gently forming a swirl from the center to the circumference Connect the cable properly referring to the following list entitled Auto iris Cable connections This lens is a precision optical product Avoid dropping strong vibration shock and pressure on it Keep the lens away f
8. PENTAX TS10V518AED PENTAX CCTV E
9. e shortest or longest focal lengths adjust the back focus of the camera by the following method referring to the Operating Instructions of the camera Fully open the iris by either of the following methods Set the auto electronic shutter of the camera to On Cover front of the lens with a ND filter according to the prevailing lighting conditions The brighter the lighting conditions a higher ND factor is required Observe an image of a distant object Over 10m is recommended Set the zoom ring at TELE position and the focus ring at FAR position and then adjust back focus of the camera Make focus adjustments with the focusing ring confirming that objects are in focus across the entire zoom range especially at the TELE and WIDE positions m CE marking CE marking on the body is conformity with the standards EN50130 4 and EN55022 related to EMC directives by EU E After sales servicing Contact your supplier for after sales servicing E Composition Lens body Front cap Operating instructions E External view This pin configuration is conforming to JEITA Standard WIN Rear cap M i for zoom for focus Fixing lever E Main specifications Format size 1 3 Mount CS Focal length 5mm 50mm Iris range F1 8 F360 Min object distance 0 6m Driving coil 1900 10 20 C Damping coil 7000 10 20 C
10. rom dust poisonous gas moisture and salt It may cause lens malfunction E Mounting and removing the lens Before mounting the lens confirm the camera mount matches the lens This lens cannot be used on a C mount camera Some cameras are C and CS mount compatible Refer to the Operating Instructions of the camera Screw the lens clockwise into the camera Eventually the clutch of the lens will start slipping Keep turning the lens until the clutch reaches its stop The lens position is now adjustable counter clockwise in about 320 degrees Turn the lens until the correct position is achieved When removing the lens keep turning the lens counter clockwise until the lens comes off HOYA CORPORATION PENTAX Imaging Systems Division Security Systems Sales Department 2 36 9 Maeno cho Itabashi ku Tokyo 174 8639 Japan Phone 81 3 3960 0347 Fax 81 3 3960 0337 3170509 Z2 2 E S3095046 E Auto iris Cable connections nstallation of the auto iris Cable This is a DC Drive iris lens Pin No Color Specifications Red Damping Coil Black Damping Coil White Driving Coil 4 Green Driving Coil Japan Electronics and Information Technology Industries Association E Iris adjustment This is a DC Drive iris lens Please refer to Operating Instructions of the camera Adjusting back focus The flange back of this lens is factory adjusted for CS mount camera In case you are unable to focus either at th