1. WARNING Caution M10 threaded holes for earthing Make sure the earthing procedure is car ried out properly Unhook the AVR voltage regulator before carrying out this test Important The windings are tested under high tension WARNING during production Additional high tension tests can weaken the insulation thereby reducing the working lifespan If a high tension test should prove neces sary for customer approval these tests should be carried out at lower voltages The generator leaves the production line with a star series connection unless otherwise specified on order which are used as reference for its nominal data In the event of any subsequent changes the installer must undertake to mark the new connection used on the machine data plate located inside the terminal box To change connection consult the diagrams in the appendix of this manual All changes in connection must be carried out solely by a qualified specialist 22 JB4 Dicembre 2003 Rev 01 between the generator housing and its base an earth conductor should be connected in parallel through the flexible support and be adequately sized usually half of the section of the main line cables The rear shield next to the feet has two M10 threaded holes that can be used when earthing the housing see figure on the left Warning Make sure the earthing procedure is carried out properly 6 4
2. If the voltage is set any higher than its maxi mum limit the generator may be damaged If the bottom speed is set at too low a fre quency the generator may be damaged On the other hand too high a frequency can cause voltage drops with high loads Do not touch the generator while in op eration and straight after the generating set has stopped since certain parts may still be very hot The lack of routine check ups and poor maintenance can cause severe damage to persons and or objects JB4 Dicembre 2003 Rev 01 23 ENGLISH WARNING DANGER The maintenance and fault diagnostic procedures involve risks that may cause severe injury or even death These pro cedures should therefore be carried out solely by qualified electrical and me chanical specialists Before any mainte nance and cleaning work make sure that there are no live parts that the generator housing has cooled to ambient tempera ture that the electricity generating set can not be accidentally started up and that all procedures are strictly observed Important A bearings lifespan is closely linked to the working conditions and environment Long periods of sustained vibrations can damage the bearing balls and their seat Too high humidity can emulsify the grease and encourage corrosion Intense vibrations caused by the motor or bad alignment of the components in the electricity generating set pu
3. gy LL 2 sway ev LL Z y g Uejoomed var Avs euedues olyoJadoy 550710991 21938 2 9930 ounie 48A09 8pIS olyosadog 650710991 0505708 Jopein a AV 9XZ 9 Q SNY AnajejnBas 9309 d E 9XZE a qisny ayassa Bay Jap ne 4 Ve 2 9 22 Bunieyols apis 18109 d WZ 9XZ2 9SNY aJojejoBa oye d YZ 9XZ 91191514 8010090 SIN ap efed 8 4aluog en SIN SIN 9 0001 9722 e esed 95522122 Inod SIA sngy 9 An eqnelyos BUISNOY 10 Jad ay 080019100092 y 08 0 9 9099 Q8XOLX9L 2099 3 5 y Bunsyrysny O8XOLX9L 9099 ex 08 01 9 5099 Aen Buds y 9958 08X0 X9 6099 Eau 8000 0 G0 SIN 10peISIE 8 AnsJejos ausog gW 0 05 SIN BUIWJ9 SIN 22032103 100090993 ogeoeing 9uloJul 9 qL9 9SSEJ Buebyoinpjaqey 181euu puejb ajqeo eusaju ou Ja ul OABIESSE 100910991 e bau
4. ale 5 YAY 4 2110139919 HAY ssajysn g ss jysn q YAY epayos 70710991 elbau par 2 218An09 ZIeMUyos par 28 19509 par oJau 012 909 01101987 var avs euedwes par AVS Joue var AVS 2420 9 yosuej4 var avs var 3vs euedweo 4 0860591 AVS 09SIQ avs enbsig AVS 99 9455 dvs Ke AVS 0051 750500991 var 3vs euedweo ejay EZdl var AVS 48H89 8 19 Ecdi VEL AVS 992015 dl var AVS auf 1198 dl var AVS euedwes fue 150600991 par AVS euedwes LZdl var AVS 48UE9 AIUD L dl var AVS 949019 JMD AVS auf LZdl var JYS euedwes 010510991 elBau 5 9491118 aff ZIEMYOS JANI var 91146 eau asouaysod eug 1501008 sse ysniq y Av ssaJysn1q 1nod am SS JYSNIQ YAY 404 194 YAY SS9 YSNIQ 104 191 ssaJysn1q YAY 199 7009015 7 20 10431504 opnosy 10JEJS 949 1118 210 5 96 113 PIIYIS 1818jUIH 5 49 19X9 par PISIUS 1884 0 paf 1508 opnos 00100221
5. N M ALTERNATORI 4 POLI BRUSHLESS g 5 a ZS OS s _ Oe ge E NDAL o oo Se Zo 285 2 2U s od gt c of gt oo all _ 7 0 5 E 6 ZI 2 D 5 oll e PTE 50956 D M 2 2 C ITALIANO 1 NORME DI SICUREZZA 2 DICHIARAZIONE DI CONFORMIT 2 1 Dichiarazione di Compatibilit elettromagnetica 3 INTRODUZIONE 3 1 Controllo targa identificativa 3 2 Posizionamento della targa con le specifiche elettriche il numero di serie e l ordine di produzione 4 PRINCIPIO DI FUNZIONAMENTO E CARATTERISTICHE DEL SISTEMA DI REGOLAZIONE DELLA TENSIONE 4 1 Scheda AVR 5 SPECIFICHE GENERALI MECCANICHE ED ELETTRICHE PER ACCOPPIAMENTO CON IL MOTORE 6 INSTALLAZIONE 6 1 Sollevamento 6 2 Fissaggio al motore 6 2 1 Montaggio forma SAE 6 2 2 Smontaggio forma SAE 6 3 Messa a terra 6 4 Controlli preliminari 6 4 1 Controllo dell isolamento 6 4 2 Senso di rotazione 6 4 3 Verifica di tensione e frequenza 6 4 4 Regolazione scheda AVR 6 4 5 Schemi di collegamento per diversi circuiti 6 4 6 Messa in marcia 7 ASSISTENZA E MANUTENZIONE 7 1 Controllo degli avvolgimenti e dello stato di isolamento 7 2 Controllo dei cuscinetti 7 3 Anomalie e rimedi 7 4 Rimozione e sostituzione di componenti e gruppi di componenti 7 4 1 Estrazione ed inserimento dell albero 7 4 2 Sostituzio
6. eleg BJOG 19342 ZIEMYIS H981g eJau pgr leuu 5009015 ssajysn1q YAY iser ssajysniq ae SSeJysniq YAY SUEM 9140139919 YAY ssajysnug ssajysn1q YAY epayos 20 10991 e au par par 2 248AN09 7 25 PEP 2 19509 par oJau Far olyaJadoy OLLOL98p var 3vs euedweo epug par AVS Joe bar AVS 939019 yosuejy var avs abuey eg var 3vs euedweo 4 0860591 AVS 0980 avs anbsig IVS 99 495 dvs dei AVS 0081 750500991 dl rar AVS euedwes E dI var AVS 183489 8119 Ecdi rar AVS 949019 dl var AVS 911146 1198 var AVS euedwes euo 150600991 AVS euedwes elfe LZdl var AVS 48HE9 L dl VEL AVS 242019 19H19 LZdl yar AVS 911146 var 3vs euedwes 010510991 elbau 1oueysod es 9491118 ZIEMYOS JENIN var 1894 esau 5 eufue LLZOLOOE ssajysniq YAY Lied OI 55 1nod 243 14 559 59 YAY 404 193114 YAY SS9 USN Q 104 197 14 ssajysn1q YAY Jed 0114 LOS LOL98p var J048 sod opnosy var
7. ITALIANO 6 4 Controlli preliminari 6 4 1 Controllo dell isolamento Prima della messa in servizio del gruppo elettrogeno ovvero dopo lunghi periodi di inattivit controllare la resistenza di isolamento verso massa degli avvolgimenti Attenzione Scollegare il regolatore di tensione AVR prima di procedere alla misurazione valori rilevati devono essere superiori a 2MOhm Nel caso in cui la resi stenza d isolamento risulti inferiore si dovr procedere alla essiccazione in forno del solo alternatore ad una temperatura compresa fra 60 e 80 C per 3 ore Prima di eseguire tale operazione occorre rimuovere il regolatore di tensione In alternativa all essiccazione in forno possibile soffiare attraverso aria calda a 60 80 C per almeno 1 ora Importante Gli avvolgimenti sono stati collaudati in alta tensione du rante la produzione Ulteriori prove in alta tensione possono deteriorare isolamento e quindi ridurre la vita operativa Se si rendesse necessario un collaudo in alta tensione per l accettazione da parte del cliente le prove dovranno essere condotte a livelli di tensione ridotti 6 4 2 Senso di rotazione Le macchine in forma SAE sono dotate di ventola unidirezionale e pertanto sono adatte a ruotare nel solo senso orario visto dal lato accoppiamento Le macchine in forma B3 sono dotate di ventola a pale radiali e quindi possono funzionare in entrambi i sensi di rotazione Il generatore vie
8. sayjonog Far PIIYOS var plas var eJouajsod 00LEOOZZL ap opt d uonesusdwos ap anbeg cora 00L q ojj uy 609100941 EI 1502 6089 au EI 1542 6089 20 1545 6059 9 1542 6089 EI 1546 6089 w EH 108350 JOJeJsy 921132 19 103635 191710 101875 JoJe s 1ebaug asneyay JOJEJS 40 S BUISNOY 1063 9 0 8 S 25560 PEL EIS 0091080607008 2 10 01 quand E 100 18681 3 ayoniquepoiq SPOIP 10301 19 1 3 var 11099 810901 IPOIP VErBEs opeulqoq par 1010 9 909 par 10704 Joyomab par 10104 var 10301 punom par 10 C0090 var var naje puen var PELIOYNT var var elojusn 212910092 EI LSWZ Z1 9 EI LSYZ ZLEI EI 1542 6159 19627 9 1542 2189 Buueog EI LSUZ ZLEI 920200991 var ezdl Jouejue var Ed UEAE ao var 48H19 var 911146 yuosy var euo 550500
9. Devono essere usati come generatori di potenza o funzione a ci rela tiva Devono essere impiegati in uno dei seguenti scenari Trasportabile senza cappottatura per fornitura di energia tempo ranea Trasportabile con cappottatura per fornitura di energia temporanea A bordo sottocoperta impiego marino previa omologazione Su veicolo commerciale trasporto su ruote refrigerazione etc Su rotaia energia ausiliaria Su veicolo industriale movimento terra sollevatori etc Installazione fissa industriale stabilimento impianto Installazione fissa residenziale commerciale e industria leggera casa ufficio ospedale Gestione d energia cogenerazione punte di assorbimento Schemi alternativi d energia generatori standard sono progettati per soddisfare le emissioni industriali e gli standard di immunit Qualora i generatori debbano rispondere ai vincoli di emissione per le zone residenziali commerciali e per l industria leggera alcuni accessori aggiuntivi potrebbero rendersi necessari Lo schema di installazione richiede la connessione della carcassa del generatore con il conduttore di messa a terra usando un cavo di sezione adeguata e di minima possibile lunghezza e L uso di parti di ricambio non originali o non espressamente autorizzate comporta il decadimento della Garanzia Sincro la cessazione della re sponsabilit per quanto concerne la conformit alle no
10. Die Sicherung kontrollieren Die Geschwindigkeit um 15 erh hen Einen Augenblick lang an den Polen des elektronischen Reglers eine Spannung von 12V einer Batterie die mit einem Widerstand von 300hm seriengeschaltet ist anwenden unter Einhaltung der Polung Nach der Erregung erfolgt eine Aberregung Die Anschlusskabel kontrollieren wobei man sich der beigef gten Zeichnungen bedient Im Leerlauf niedrige Spannung Die Spannung nacheichen Die Drehzahl kontrollieren DEUTSCH Die Wicklungen kontrollieren Im Leerlauf zu hohe Spannung Die Spannung Den Regler auswechseln Bei Lastbetrieb Spannung unter der Nennspannung Die Spannung nacheichen e Zu starker Strom cosy unter 0 8 Geschwindigkeit unter 4 des Nennwerts Den Regler auswechseln Die Dioden kontrollieren wobei die Kabel abgetrennt werden Bei Lastbetrieb Spannung ber der Nennspannung Die Spannung Den Regler auswechseln Instabile Spannung Die Gleichm igkeit der Rotation kontrollieren Die Stabilit t des Reglers durch Einwirkung auf das Potentiometer ST regeln Bei allen anderen Anomalien wenden Sie sich bitte an das Kundendienst Center Sincro 7 4 Entfernen und Auswechselung von Komponenten und Gruppen von Komponenten 7 4 1 Ausbau und Einbau der Welle BeidennachstehendbeschriebenenArbeitsablaufen wird vorausgesetz
11. bordo bajo cubierta empleo marino previa homologaci n Sobre veh culo comercial transporte por carretera refrigeraci n etc Sobre v as energ a auxiliar Sobre veh culo industrial movimiento de tierras elevadores etc Instalaci n fija industrial f brica instalaci n Instalaci n fija residencias comercial e industria ligera casa oficina hospital Gesti n de energ a cogeneraci n puntas de absorci n Esquemas alternativos de energ a Los generadores est ndar han sido dise ados para cumplir las emisiones industriales y los est ndares de inmunidad En el caso de que los generadores deban cumplir las obligaciones de emisi n en zonas residenciales comerciales y para la industria ligera podr ser necesario instalar algunos accesorios adicionales El esquema de instalaci n requiere la conexi n de la carcasa del generador al cable de puesta a tierra que ser lo m s corto posible y con una secci n adecuada Eluso de piezas de recambio no originales o no autorizadas expresamente conlleva la invalidaci n de la Garant a Sincro y la liberaci n de la responsabilidad por lo que concierne la conformidad a las normativas y relativas consecuencias Tanto la instalaci n como la asistencia y mantenimiento ser n llevados a cabo por personal instruido de forma adecuada y con conocimiento de los dict menes de las directivas CE 3 INTRODUCCI N Al recibir el ge
12. apis uo aJojejoBa oye g 0505708 01100906 1 YZ 9XZ elqIsn4 VAXGOL 06 OLN ap efeo 4 9XZ 9 QISNY VAYSOL 06 OLIN 191 108 3 ve oer Bunieyais VAHSOL 06 OLW Cave 9SNY VAISOL 06 YZ 9XZ WAXSOL 06 OLN 22H2SION 910001 9722 e esed asseoseo Inod SIA asneyas eqnelyos 10 M919S Jad aun 60111800094 y ZOLXLLXgL 9099 ZOLXLLXBL 9099 SHOAMEJO y Bunsynsny ZOLXLLXBL 9099 ZOLXLLX8L 6099 Aen Buds 2140 9989 8 9099 0100701808 VANSOL 06 Jopeisie VAYSOL 06 OLIN ausog WANSOL 06 OLW VAHSOL 06 OLIN euro 10 e NSUI VISO L 06 OLIN 0 0 oyas oy 100090995 ogeoeing ajqeo assed Bue ya npjagey puej6 age jeuisju OUJ U OABDESSEA 500510991 e bau ele SIN9JIQUUOI Sog 19 42 4 ZIEMYIS H981g eJau euu 2009012 ss jysn q jolie ss jysn q
13. ITALIANO Trimmer V Trimmer ST Trimmer UF Temp ambiente C 40 Altitudine m Fattore di potenza 6 JB4 Dicembre 2003 Rev 01 del 1 nel campo operativo della macchina con carichi non distorcenti La tensione di uscita pu essere regolata tramite il trimmer V vedi figura da 185 a 290V con una tolleranza del 10 Tramite ponticello aggiuntivo possibile portare il campo di variazione da 220 a 320V sempre con una tolleranza del 10 Il regolatore dotato di una protezione di limitazione di eccitazione in funzione della frequenza la taratura della frequenza avviene tramite il trimmer UF la pretaratura avviene a 46Hz 1Hz Al raggiungimento di tale frequenza la macchina inizia a diminuire la propria tensione fino a diseccitarsi per frequenze molto basse Un fusibile protegge il regolatore e il generatore da eventuali sovraccarichi e o guasti una apposita tasca ricavata sul bordo della scheda contiene un fusibile di scorta fusibile tipo 32x6 3 2 5A rapido Un ulteriore trimmer ST permette di adattare il regolatore ai parametri del generatore Il regolatore stato costruito per contenere al minimo i picchi di tensione al distacco del carico che risultano inferiori al 20 con carico nominale 5 SPECIFICHE GENERALI MECCANICHE ED ELETTRICHE PER AC COPPIAMENTO CON IL MOTORE In quanto unit separata e destinata ad essere incorpo
14. to terminals 0 and 115 for an output voltage between 100 and 140V factory setting to terminals 0 and 230 for an output voltage between 200 and 280V To increase the range of available voltages by about 15 use terminal Pa instead of terminal 0 Caution if the voltage is set any higher than its maximum limit the generator may be damaged Setting the bottom speed at 50 60 Hz start up rotation of the generating set adjusting it to obtain a frequency of 46 56 Hz Turn trimmer UF until the voltage begins to drop Restore nominal speed Caution if the bottom speed is set at too low a frequency the generator may be damaged On the other hand too high a frequency can cause voltage drops with high loads Connecting an external potentiometer 5kOhm remove the jumper on terminals EXT POT and wire the potentiometer to the free terminals how ever make sure that it is set at its maximum resistance Turn trimmer anticlockwise to its limit Take the generating set to its nominal speed and adjust the potentiometer until the required voltage is obtained If on load voltage fluctuations are experienced adjust potentiometer ST which modulates the reaction time of the regulator to external inputs thereby eliminating any instability in the alternator load system 6 4 5 Wiring diagrams for different circuits In the appendix of this manual there are diagrams for any connectio
15. Dentro de la caja de bornes se hallan los bornes aislados para las conexiones de l nea y de neutro y para la conexi n de tierra El neutro NO est conectado a la carcasa Advertencia Se suministra el generador sin conexi n de tierra para efectuar dicha conexi n se tendr n como referencia las correspondientes disposiciones locales Conexiones de tierra o de protecci n ejecutadas incorrectamente pueden ocasionar lesiones o incluso la muerte Sobre demanda se proporcionan los valores de las corrientes de aver a del generador con el fin de ayudar al proyectista en el dimensionamiento de la instalaci n y de sus componentes Advertencia Tanto la instalaci n como el uso mantenimiento o sustituci n de piezas efectuados de manera incorrecta pueden ocasionar graves lesiones personales o incluso la muerte as como da os a los aparatos Los trabajos en las partes el ctricas y o mec nicas ser n realizados por personal cualificado 6 INSTALACI N 6 1 Izado Izar y mover el generador con medios aptos para ello apoy ndolos sobre ESPA OL paletas o sosteni ndolos mediante los anillos para izar puestos en el generador en las posiciones indicadas en la figura Para izar el generador utilizar dispositivos con capacidad de izada de por lo menos 400kg Atenci n Una capacidad de izada no adecuada puede ocasionar lesiones personales y da os graves Atenci n Los anillos para izar del generador est n des
16. ap 001 ap anbeg 001 g dn 00 ojj uy 609100941 89 1548 6089 EI 1542 6059 Juawe noy 89 1542 6059 19527 9 1542 6089 20 153 6089 78 99 901 06 eleo par Joes 0 06 491310g par 107875 WAMSOL 06 J0Je S vAxS01 06 Bursnoy 103835 VAXGOL 06 esseo par 3215 0091080607008 var 2 20 quand 10301 E 100 18681 3 10301 19 1 3 var 1999 a10 04 DOP 75 859 par 10104 par 10704 yeyoimab par 10104 var 10301 punom pagr 10 C0090 var Jope yuaA var var var uey var eloqus A 7159100911 EI 1542 7159 U00 EI 1545 7159 4 20 LSYZ 41E9 19627 9 1542 7189 CO 1540 7169 oyaulosny 212910092 EI LSUZ ZLEI EI LSYZ ZLEI EI 1542 2159 19627 9 1542 2189 EI LSUZ ZLEI SEOZOOSIL var ezdl Jonajue Il var Ed UEAE ao var 48H19 var 911146 yuosy var enbuo c 0c0
17. 7 3 Anomal as y remedios 7 4 Desmontaje y sustituci n de componentes y grupos de componentes 7 4 1 Extracci n e inserci n del eje 7 4 2 Sustituci n del cojinete 7 4 3 Sustituci n de los diodos rotatorios 7 4 4 Reemsamblaje de los componentes y de los grupos de componentes 8 LIMPIEZA Y LUBRICACI N 9 DEMOLICI N Y ELIMINACI N 10 RECAMBIOS Y ASISTENCIA 10 1 Procedimientos y direcciones de referencia para solicitudes de asistencia 11 GARANT A JB4 Dicembre 2003 Rev 01 57 ESPANOL Importante Se refiere a situaciones de riesgo o procedimientos peligrosos que podr an ocasionar da os al producto o a los aparatos conectados 58 JB4 Dicembre 2003 Rev 01 1 NORMAS DE SEGURIDAD Sincro S r l les da las gracias por haber elegido uno de sus productos en la certeza de que Uds obtendr n las mejores prestaciones para sus exigencias El Manual de uso y mantenimiento que acompa a el generador proporciona importantes indicaciones concernientes tanto la seguridad como la instalaci n el uso y el mantenimiento Este producto cumple las normas del buen hacer as como las disposiciones sobre seguridad Para comunicaciones con Sincro Srl les rogamos indiquen siempre el tipo y el c digo del generador anotados en la etiqueta puesta en el embalaje Asimismo en el caso de anomal as de funcionamiento u otros tipos de aver as de la m quina al acudir a nuestro Servicio de Asistencia indiquen po
18. Dicembre 2003 Rev 01 DEUTSCH 1 SICHERHEITSNORMEN Die Firma Sincro S r l dankt Ihnen f r den Vorzug den Sie diesem Produkt gegeben haben und ist berzeugt dass es Ihnen die f r Ihren Gebrauch erforderlichen Leistungen liefern wird Die dem Generator beigef gte Bedienungs und Wartungsanleitung liefert wichtige Hinweise zu Sicherheit Installierung Gebrauch und Wartung Dieses Produkt erf llt die anerkannten Regeln der Technik und der Sicher heitsvorschriften Es wird gebeten bei der Korrespondenz mit der Firma Sincro Srl stets den Typ und die Kennnummer des Generators anzugeben die aus dem im Packst ck vorhandenen Etikett hervorgehen Falls au erdem an der Maschine Funktionsst rungen oder sonstige Defekte vorliegen sollten und die Einschaltung unseres Kundendienstes erforderlich w re wird gebeten auch die Seriennummer SN und den Produktionsauftrag PO bekanntzugeben ACHTUNG Eine falsche Installierung oder ein unsachgem er Gebrauch des Produkts kann Personen oder Sachsch den bewirken Die Hinweise der Bedienungs und Wartungsanleitung genau befolgen ihr Zweck liegt darin die korrekten Installierungs Anwendungs und Wartungsbedingungen anzuzeigen um eventuellen Funktionsst rungen des Generators vorzubeugen und Gefahrsitutationen f r den Benutzer zu vermeiden Die Verpackungsmaterialien Plastik Karton Polystyrol etc gem den geltenden Normen entsorgen e Die Anl
19. NY U S A Ph 001 845 2920800 Fax 001 845 2920830 E mail postmaster getec com Holland Belgium Luxembourg Meijco Elektro Holland Pastoor Vav Laakstraat 56 6663 CB LENT HOLLAND Ph 0031 243220085 Fax 0031 243233197 e mail meyco elektro worldonline nl South Africa Power Equipment Sales 8 Services Rep 14 Fraaiuitsig St Glentana Po box 1897 George WP 6530 RSA Ph 0027 448790680 Fax 0027 448791837 Australia New Zealand Pacific Islands Sincro Australia Pty Ltd Po box 177 2 22 Tepko Rd Terrey Hills NSW AUSTRALIA Ph 0061 294500993 Fax 0061 294500663 E mail sales sincro com au 78 JB4 Dicembre 2003 Rev 01 Poland Scanger Ul Gen Sikorskiego 21 23 62 031 Lubon K Poznania POLAND Ph 0048 618139478 Fax 0048 618139479 Russia Perpetuum Mobile Ltd Moscow ul Smolnaya 24a office 1609 Ph 007 095 937867 Fax 007 095 937867 E mail sales p mobile ru United Arab Emirates Aikah Establishment Airport Rd P o Box 5804 DUBAI Ph 00971 4 3478005 Fax 00971 4 3478006 Israel Shatal Engineering 1992 Ltd 3 Nahal Poleg St PO Box 32YAVNE 81100 Israel Ph 00972 8 9320202 Fax 00972 8 9428763 E mail shatal shatal com Dichiarazione di conformit Conformity certificate Konformit tserkl rung Declaration de conformit Declaraci n de La societ The company Die Firma La soci t La sociedad SINCRO S r l Via Te
20. la carcasse Avertissement Le g n rateur est fourni sans aucune connexion la terre pour l effectuer il faudra se r f rer aux normes locales en vigueur Des mises la terre ou des connexions de protection effectu es de FRAN AIS mani re erron e peuvent tre cause de l sions ou de mort Les valeurs des courants de panne du g n rateur sont disponibles sur demande afin d aider l auteur du projet dimensionner correctement l installation et ses composants Avertissement L installation l utilisation la maintenance ou le remplacement de pi ces effectu s de mani re erron e peuvent tre la cause de graves l sions personnelles ou de mort ainsi que de dommages aux quipements Les interventions sur les parties lectriques et ou m caniques doivent tre effectu es par du personnel qualifi 6 INSTALLATION 6 1 Levage Soulever et d placer le g n rateur avec des engins appropri s en utilisant une palette ou les anneaux de levage pr sents sur le g n rateur dans les positions indiqu es sur la figure Pour soulever le g n rateur utiliser des dispositifs ayant une capacit de levage d au moins 400kg Attention Une capacit de levage insuffisante peut causer des l sions personnelles et de graves dommages Attention Les anneaux de levage pr sents sur le g n rateur ont t r alis s pour soulever uniquement le g n rateur et non pas tout le groupe lectrog ne Le levage
21. 1 all General Safety Requi rements as provided by the EEC Low Voltage Directive dated 19 February 1973 73 23 EEC 2 all principal safety require ments specified by the Commit tee for Adapting Member States Legal Regulation on Electro magnetic Compatibility 89 336 EEC 93 68 EEC The following standards were used to evaluate the electro magnetic compatibility dar berhinaus erf llen sie 1 die allgemeinen Sicherheits anforderungen der Richtlinie f r Niederspannung vom 19 Februar 1973 73 23 CEE in Italien mit dem Gesetz Nr 791 vom 18 Oktober 1977 aufgenommen 2 die Richtlinie 89 336 CEE Mod der 93 68 CEE bez glich der Ann herung der Gesetzgebungen der Mitgliedsstaaten in Sachen elektromagnetischer Kompatibi lit t Die Kompatibilit tspr fung wurde mit Zugrundelegung folgender Normen ausgef hrt et sont conformes 1 Aux conditions g n rales de s curit tablies par la Directive relative la basse tension du 19 F vrier 1973 73 23 CEE adopt e par l Italie par promulgation de la loi n 791 du 18 Octobre 1977 2 A la Directive 89 336 CEE et modifications suivantes 93 68 CEE concernant l harmoni sation des l gislations des tats membres en mati re de compa tibilit lectromagn tique La v rification de compatibilit a t effectu e conform ment aux normes suivantes y cumplen 1 las prescripciones que sobre seguridad quedan definidas en la Norma sobre
22. del cojinete 7 4 4 Reemsamblaje de los componentes y de los grupos de componentes Para la operaci n de reemsamblaje realizar las operaciones citadas anteriormente para el desmontaje pero con secuencia inversa ESPA OL 8 LIMPIEZA Y LUBRICACI N Advertencia Toda intervenci n de limpieza ser realizada con el grupo electr geno parado y con el generador desconectado de la red el ctrica so pena de peligro grave para las personas y las cosas Comprobar que el grupo electr geno est parado y desconectado de la red el ctrica Se puede limpiar el grupo por fuera con aire comprimido Advertencia No utilizar nunca l quidos o agua No limpiar con aire comprimido las partes el ctricas interiores pues se podr a provocar cortocircuitos u otras anomal as 9 DEMOLICI N Y ELIMINACI N Advertencia Servirse solamente de personal cualificado La eliminaci n de los materiales ser efectuada en la observancia de las normas vigentes En el caso de demolici n del generador no existen riesgos particulares o peligros derivantes del generador De recuperarse los materiales es conveniente separarlos por tipos partes el ctricas cobre aluminio pl stico etc 10 RECAMBIOS Y ASISTENCIA 10 1 Procedimientos y direcciones de referencia para solicitudes de asistencia Nuestro Servicio de Asistencia proporciona una completa asesor a t cnica En caso de solicitud de Asistencia en garant a comprobar que se dispone
23. lectromagn tique Les g n rateurs JB4 sont construits avec des crit res et des mat riaux qui en certifient la compatibilit avec les Directives europ ennes suivantes CEE 73 23 CEE 89 336 98 37 CE et modifications successives ainsi qu aux normes CEI 2 3 EN 60034 1 EN 55011 EN 50081 1 EN 50082 1 Les g n rateurs type JB4 sont en outre fournis sur les bases suivantes Ils doivent tre utilis s comme g n rateurs de puissance ou pour une fonction qui y soit relative 15 doivent tre utilis s dans l une des configurations suivantes Transportable sans capot pour fourniture temporaire d nergie Transportable avec capot pour fourniture temporaire d nergie bord sous le pont application marine apr s homologation Sur v hicule commercial transport sur roues r frig ration etc Sur rail nergie auxiliaire Sur v hicule industriel terrassement engins de levage etc Installation fixe industriel usine installation Installation fixe r sidentielle commerciale et industrie l g re maison bureau h pital Gestion d nergie cog n ration pics d absorption Sch mas alternatifs d nergie e Les g n rateurs standard sont projet s pour satisfaire les missions industrielles et les standards d immunit Si les g n rateurs doivent satisfaire les limites d mission pour les zones r sidentielles commerciales ou pour l industrie l g re ce
24. ENGLISH Any kind of cleaning work must be carried out with the generating set shutdown and the mains power shut off for the risk of WARNING severe hazard for persons and objects Never and for no reason whatsoever use fluids or water Do not use compressed air to clean internal electrical parts since this could cause short circuits or related problems Only use authorised specialists 26 JB4 Dicembre 2003 Rev 01 Take the new bearing or bearings and heat them so their diameter dilates before sliding them into position on the shaft Replace the snap ring Insert the rotor by following in reverse the instructions at section 7 4 1 As an alternative the bearing can be changed without extracting the rotor Unscrew the 4 bolts that fasten the back shield to the housing Hammer the shield evenly until it comes away from the rotor Remove the snap ring Remove the bearing using a standard extractor Take the new bearing and heat it so its diameter dilates before sliding it into position on the shaft Replace the snap ring Position the shield remembering to insert the snap ring and fit the screws leaving them loose Hammer the shield evenly until the bearing and section of housing are in place Tighten the bolts on the shield 7 4 3 Changing rotating diodes Extract the rotor following the instructions at section 7 4 1 e Unhook the diode bridge e Unscrew the screw
25. Spannungsniveaus durchgef hrt werden 6 4 2 Drehrichtung Die Maschinen in Form SAE sind mit in einer Richtung drehendem L fterrad ausgestattet und sind somit nur zur Drehung im Uhrzeigersinn von der Kupplungsseite aus gesehen geeignet Die Maschinen in Form B3 sind mit L fterrad mit Radialschaufeln ausgestattet und k nnen somit in beiden Drehrichtungen arbeiten HINWEIS Ein ungeeigneter Schutz und oder eine falsche Fluchtung des Generators k nnen zu Verletzungen von Personen und oder Sch den an der Ausr stung f hren Sicherstellen dass der Verfahrensablauf der Erdung korrekt abgewickelt wird gt 4 REG 227 Gewindebohrungen M10 f r Erdung Achtung Den Spannungsregler AVR abtrennen bevor die Messung vorgenommen wird Die Abnahmepr fung der Wicklungen erfolgte unter Hochspannung w hrend der Produktion Weitere Pr fungen unter Hochspannung k nnen die Isolierung ver schlechtern und somit ihre Lebensdauer reduzieren Falls sich eine Abnahme unter Hochspannung zur Akzeptierung seitens des Kunden als erforderlich erweisen soll te m ssen die Pr fungen auf verminderten Spannungsniveaus durchgef hrt werden JB4 Dicembre 2003 Rev 01 35 DEUTSCH HINWEIS Trimmer V Trimmer ST Der Generator verl sst die Produktionslinien mit einer Stern Serienschaltung sofern bei Auftragserteilung nicht ande
26. agr s est disponible sur notre site internet WWW sogagroup com 11 GARANTIE Sincro s r l garantit la qualit la s curit et la fiabilit de tous ses produits La p riode de garantie contre les pannes ou les probl mes de fonctionnement d rivant de vices de construction ou de mat riaux est de 12 mois partir de la date de livraison La p riode de garantie ne pourra tre prorog e en aucun A AVERTISSEMENT N importe quel type d intervention de nettoyage doit tre effectu e avec le groupe lectrog ne arr t et le g n rateur d branch sous peine d exposer les personnes et les choses un grave danger N utiliser en aucun cas des liquides ou de l eau Ne pas nettoyer l air comprim les parties lectriques internes car cela pourrait provoquer des courts circuits ou d autres anomalies Faire appel exclusivement du personnel qualifi JB4 Dicembre 2003 Rev 01 55 FRAN AIS 56 JB4 Dicembre 2003 Rev 01 cas m me si l alternateur n a pas t mis en service dans l intervalle Si durant la p riode de garantie des d fauts de fabrication ou de montage de composants devaient se manifester Sincro s r l r parera ou remplacera ses frais les parties d fectueuses le plus rapidement possible La d nonciation du d faut devra tre faite dans les 8 jours qui suivent sa d couverte sous peine de perte de la garantie Les interventions la charge de Sincro d
27. and axial strains they undergo vibrations can increase considerably with a bad alignment and on the working conditions So check for any unusual signs vibrations unusual noises clogged air vents If undue vibrations or noises appear after long term usage these could be due to a worn bearing that if damaged has to be replaced The bearing should always be replaced after 20 000 working hours Bearings on generators with belt transmissions since they undergo greater loads than generators driven by direct couplings usually have a shorter lifespan and should be changed after 15 000 working hours Important A bearings lifespan is closely linked to the working condi tions and environment Important Long periods of sustained vibrations can damage the bear ing balls and their seat Too high humidity can emulsify the grease and encourage corrosion Important Intense vibrations caused by the motor or bad alignment of the components in the electricity generating set put the bearing under stresses that will reduce its lifespan 7 3 Troubleshooting The generator will not excite Check the fuse Increase speed by 15 Apply a 12V voltage for an instant across the electronic regulator terminals using a battery with a 300hm resistance in series and remember to respect the polarities After it is excited it deactivates Check the wiring against the diagrams in appendix No load voltage too low Calibrate the volt
28. appliquant aux bornes de Pexcitatrice une tension de 6 12 volts pendant une seconde en respectant la polarit 54 JB4 Dicembre 2003 Rev 01 7 4 Enl vement et remplacement de composants et groupes de composants 7 4 1 Extraction et mise en place de l arbre Les proc dures qui suivent pr supposent que l alternateur ait t d connect du moteur Version double roulement et conique D visser les 8 vis M10 qui fixent le bouclier sur la bride entretoise cette op ration n est pas n cessaire pour la version SAE 2 Frapper le bouclier de mani re homog ne jusqu au d tachement complet du rotor version double roulement et de la bride entretoise version conique e Enlever la grille arri re et frapper le rotor l arri re de mani re faire sortir le roulement de son logement Supporter le rotor avec une lingue c t accouplement e Continuer pousser le rotor hors du stator en continuant adapter la position de l lingue de mani re pas endommager l enroulement Version un seul roulement SAE D visser les 8 vis M10 qui fixent le bouclier sur la bride entretoise cette op ration n est pas n cessaire pour la version SAE 2 e Enlever la grille arri re et frapper le rotor l arri re de mani re faire sortir le roulement de son logement e Supporter le rotor avec une lingue c t accouplement e Continuer pousser le rotor hors du stator en continuant adapter
29. become a source of hazard Sincro S r l declines all liability arising from any use whether improper or differing from its original concept and specified in this manual Do not install the product in a potentially explosive atmosphere The plant component elements must comply with European Directives To ensure good safety levels these standards should also be observed in non EEC countries in addition to the country specific statutory regulations The installation must comply with European Directives and must be carried out solely by qualified specialists Do not start up the generator ifthe protective covers the access panels or the terminal box cover have been removed Before starting any maintenance work shut off the motor power circuit Shut off the actuator circuits and or place warning decals on all circuit breakers normally used for connecting the mains or other generators in order to prevent them from being switched accidentally Only use genuine parts for any maintenance or repair Failure to observe this recommendation shall free Sincro S r l from all responsibility related to the generator safety and good operation Train the plant operator in the management use and maintenance of the generator Anything not expressly prescribed in these instructions is prohibited This manual uses various symbols and terms that have a precise meaning These are clearly defined below Important This refers to risk conditions or to hazard
30. cooling fan What s more the generator air vent should be constructed to prevent damp from entering by fitting a suitable filter The housing should be designed so that there is a minimum clearance of 50mm between the generator air vent and any flat surface If specified on order the generator can be fitted with air filters Important A drop in cooling air flow or inadequate protection of the generator can lead to damage and or malfunction of the windings The generator s rotor assembly is factory balanced dynamically with full key dual bearing version The motor induces quite complex vibrations including overtones that when added to the generator vibrations can cause substantial vibration levels damaging for the electricity generating set operation Therefore it is essential that the plant engineer takes all necessary measures to ensure alignment and provide a firm base and supports in order to prevent vibrations from exceeding the standard Dual bearing generators require a rigid frame to support the motor generator so that a good base is established for a precise alignment This frame should be anchored to the base with antivibration plugs In order to minimise twist oscillations it is advisable to use a suitably sized flexible joint In belt transmissions applied to dual bearing generators it is essential that the pulley diameters and constructions permit the load applied to the shaft to be centred with the length of the nub and no
31. d rivant d une utilisation impropre ou diff rente de celle pour laquelle le produit est con u et qui est indiqu e dans la pr sente documentation Ne pas installer le produit dans une atmosph re potentiellement explosive e Les l ments constituant l installation doivent tre conformes aux Directives Europ ennes Pour tous les Pays hors CEE en plus des normes nationales en vigueur pour un bon niveau de s curit il est opportun de respecter galement les normes susmentionn es e L installation doit tre conforme aux prescriptions des Directives Europ ennes et doit tre ex cut e exclusivement par du personnel qualifi Ne pas mettre en marche le g n rateur si les carters de protection les panneaux d acc s ou de couverture de la bo te bornes ont t enlev s e Avant toute op ration d entretien d sactiver les circuits de d marrage du moteur e D sactiver les circuits de fermeture et ou placer des panonceaux d avis sur chaque interrupteur automatique habituellement utilis pour la connexion au secteur ou d autres g n rateurs afin d en pr venir la fermeture accidentelle Utiliser exclusivement des pi ces originales pour toute op ration d entretien ou r paration En cas de non respect de cette prescription Sincro S r l d cline toute responsabilit en ce qui concerne la s curit et le bon fonctionnement du g n rateur e Instruire l utilisateur de l installation pour la gestion l uti
32. de los datos identificativos del generador de su n mero de serie y del n mero de pedido de producci n indicados en la etiqueta adhesiva puesta seg n la indicaci n del apartado 3 2 del presente manual Uds podr n visionar el listado de los centros autorizados en nuestro sitio internet www sogagroup com 11 GARANT A Sincro s r l garantiza la calidad seguridad y fiabilidad de todos sus productos El periodo de garant a contra aver as o malfuncionamientos debidos a defectos de fabricaci n o de los materiales es de 12 meses a partir de la fecha de entrega En ning n caso se prorrogar n las condiciones de garant a aunque el alternador no haya sido entretanto puesto en servicio En el caso de que durante el periodo de garant a se manifestaran defectos de elaboraci n o de montaje de materiales Sincro s r l reparar o sustituir las partes defectuosas en el tiempo m s breve posible corriendo con los gastos Se avisar del defecto en un plazo de 8 d as de haberlo descubierto so pena la anulaci n de la garant a Las intervenciones a cargo de Sincro ser n realizadas en su propia f brica Todos los gastos relativos al transporte del producto a reparar correr n a cargo del cliente La garant a se anular en el caso se manifestaran inconvenientes o aver as debidos a impericia uso con superaci n de los l mites de las prestaciones nominales modificaciones del producto o si los alternadores se restituyeran desmontados o con
33. den axialen Lasten denen sie ausgesetzt sind die Vibrationen k nnen im Fall einer falschen Fluchtung betr chtlich erh ht sein sowie von den Arbeitsbedingungen ab Es muss daher berpr ft werden dass keine Anomalien wie Vibrationen ungew hnliche Ger usche und verstopfte Luftauslass ffnungen vorliegen Falls nach einer gewissen Zeit berm ige Vibrationen oder Ger usche auftreten sollten k nnten diese auf den Verschlei des Lagers zur ckzuf hren sein das bei Besch digung ausgewechselt werden muss Es ist jedoch auf jeden Fall anzuraten das Lager nach 20 000 Betriebsstunden auszuwechseln Die Lager der Generatoren mit Riemenantrieb haben nachdem sie h heren Lasten als die Lager der durch direkte Kupplung angetriebenen Generatoren ausgesetzt sind normalerweise eine k rzere Lebensdauer und m ssen nach 15 000 Betriebsstunden ausgewechselt werden Wichtig Die Lebensdauer der Lager wird durch die Arbeitsumgebung stark beeinflusst Wichtig Lange Verweilzeiten an einem Ort an dem Vibrationen vorhanden sind k nnen die Kugeln und die W lzsitze besch digen Eine zu hohe Feuchtigkeit kann die Emulsion des Fetts bewirken und Korrosionseffekte beg nstigen Wichtig Intensive Vibrationen die vom Motor oder durch eine falsche Fluchtung der Komponenten des Elektro Aggregats bewirkt werden setzen die Lager Beanspruchungen aus die ihre Lebensdauer verk rzen 7 3 Anomalien und Abhilfe Der Generator erregt sich nicht
34. der Fl che des Querschnitts der Kabel der Hauptleitung in Parallelschaltung angeschlossen werden Warnhinweis Sicherstellen dass der Verfahrensablauf der Erdung korrekt abgewickelt wird Auf dem hinteren Schild sind auf der H he der F e zwei Gewindebohrungen M10 vorbereitet um die Erdung des Kastens zu erleichtern siehe Abbildung 6 4 Vorbereitende Kontrollen 6 4 1 Kontrolle der Isolierung Vor der Inbetriebnahme des Elektro Aggregats bzw nach langen Stillstandzeiten den Isolierungswiderstand der Wicklungen zur Erde kontrollieren Achtung Den Spannungsregler AVR abtrennen bevor die Messung vorgenommen wird Die ermittelten Werte m ssen ber 2MOhm liegen Falls sich der Isolierungswiderstand als niedriger erweist muss eine Trocknung des Drehstromgenerators allein im Ofen bei einer Temperatur von 60 80 C ber 3 Stunden vorgenommen werden Vor Ausf hrung dieses Arbeitsvorgangs den Spannungsregler entfernen Als Alternative zur Trocknung im Ofen besteht die M glichkeit mindestens 1 Stunde lang Hei luft durch den Drehstromgenerator zu blasen bei 60 80 C Wichtig Die Abnahmepr fung der Wicklungen erfolgte unter Hochspannung w hrend der Produktion Weitere Pr fungen unter Hochspannung k nnen die Isolierung verschlechtern und somit ihre Lebensdauer reduzieren Falls sich eine Abnahme unter Hochspannung zur Akzeptierung seitens des Kunden als erforderlich erweisen sollte m ssen die Pr fungen auf verminderten
35. einem Ort an dem Vibrationen vorhanden sind k nnen die Kugeln und die W lzsitze besch digen Eine zu hohe Feuchtigkeit kann die Emulsion des Fetts bewirken und Korrosionseffekte beg nstigen Intensive Vibrationen die vom Motor oder durch eine falsche Fluchtung der Komponenten des Elektro Aggregats bewirkt werden setzen die Lager Bean spruchungen aus die ihre Lebensdauer verk rzen 38 JB4 Dicembre 2003 Rev 01 7 1 Kontrolle der Wicklungen und des Zustands der Isolierung Der Zustand der Wicklungen kann durch Messung ihres elektrischen Widerstands zur Erde hin berpr ft werden W hrend der Pr fung muss der Spannungsregler abgetrennt sein Im allgemeinen ist es ausreichend nur die Hauptwicklung zu kontrollieren Die ermittelten Werte m ssen ber 2MOhm liegen Falls sich der Isolierungswiderstand als niedriger erweist muss eine Trocknung des Drehstromgenerators allein im Ofen bei einer Temperatur von 60 80 C ber 3 Stunden vorgenommen werden Vor Ausf hrung dieses Arbeitsvorgangs den Spannungsregler entfernen Als Alternative zur Trocknung im Ofen besteht die M glichkeit mindestens 1 Stunde lang Hei luft durch den Drehstromgenerator zu blasen bei 60 80 C 7 2 Kontrolle der Lager Die Lager sind versiegelt und wartungsfrei W hrend der Wartung den Zustand der Lager kontrollieren und berpr fen dass keine Fettaustrittsstellen vorhanden sind Die Lebensdauer der Lager h ngt von den Vibrationen und
36. et la manutention des g n rateurs un seul roulement doivent tre effectu s en maintenant la machine en position horizontale afin d viter si lop ration n est pas effectu e correctement la sortie du rotor avec risque d endommager ce dernier et de graves cons quences pour les personnes 6 2 Fixation au moteur 6 2 1 Montage forme SAE voir figure Attention Avant le montage v rifier que les si ges d accouplement tant du g n rateur que du moteur sont r guliers et propres e Enlever la barre de fixation du rotor Enlever les grilles de protection 6 et les couvercles en plastique 7 situ s sur le carter e Contr ler que le diam tre du disque 3 correspond au diam tre de logement dans le volant 2 Fixer le g n rateur au moteur en bloquant la cloche SAE 1 et en contr lant que les trous sur le disque co ncident avec ceux du volant V rifier que le disque est en appui sur le volant en frappant axialement le rotor avec un maillet en plastique et un tampon Fixer le disque au volant e V rifier que le rotor et le stator de l excitatrice sont parfaitement align s entre eux Placer des antivibrants 5 sous le groupe en veillant la mise de niveau du moteur et du g n rateur e Remonter les grilles et les couvercles 6 2 2 D montage forme SAE Pour le d montage effectuer dans l ordre inverse les op rations d crites au paragraphe 6 2 1 Avertissement Une protection inad qu
37. la position de l lingue de mani re pas endommager l enroulement Pour la remise en place effectuer les op rations du paragraphe 7 4 1 dans l ordre inverse Attention Avant d extraire le rotor l orienter de mani re que durant le mouvement d extraction le rotor s appuie l int rieur du stator l interm diaire de la corne polaire Avertissement Quand le rotor est remis en place l alternateur peut perdre le magn tisme r siduel qui permet l auto excitation Avant la mise en marche du groupe il faut donc r exciter l alternateur en appliquant aux bornes de l excitatrice une tension de 6 12 volts pendant une seconde en respectant la polarit 7 4 2 Remplacement du roulement Se r f rer au paragraphe 7 4 1 Enlever la bague lastique type seeger e Enlever le ou les roulements a l aide d extracteurs courants e Prendre le ou les nouveaux roulements et l aide d un r chauffeur les r chauffer de mani re dilater le diam tre avant de l ins rer dans le si ge de l arbre e Remonter la bague seeger e Remettre en place le rotor en effectuant les op rations du paragraphe 7 4 1 dans l ordre inverse En alternative il est possible de remplacer le roulement sans extraire le rotor D visser les 4 vis qui fixent le bouclier arri re la caisse Frapper le bouclier de mani re homog ne jusqu au d tachement complet du rotor Enlever la bague lastique type
38. la terre Important Les enroulements ont t test s haute AVERTISSEMENT tension durant la production D autres essais haute tension peuvent d t riorer Pisolement et donc r duire la dur e de vie du composant Si un essai haute tension est n cessaire pour l acceptation de la part du client les essais devront tre effectu s des niveaux de tension r duits Le g n rateur sort des cha nes de production avec une connexion toile s rie moins de sp cifications diff rentes au moment de la commande laquelle se r f rent les donn es nominales En cas de modification successive de cette connexion l installateur est tenu de cocher la nouvelle connexion utilis e sur la plaquette des donn es machine pr sente l int rieur de la bo te bornes Pour effectuer la nouvelle connexion se servir des sch mas joints au pr sent manuel 50 JB4 Dicembre 2003 Rev 01 du g n rateur peuvent tre la cause de l sions personnelles et ou de dommages l quipement 6 3 Mise la terre La carcasse du g n rateur doit tre mise la masse de mani re solidaire sur le b ti du groupe lectrog ne Si des supports flexibles antivibrants sont pr vus entre la carcasse du g n rateur et son b ti il faudra connecter en parall le travers le support flexible un conducteur de terre d une valeur nominale ad quate g n ralement la moiti de la surface de la section transversale d
39. las placas de datos alteradas o manipuladas ADVERTENCIA Toda intervenci n de limpieza ser realizada con el grupo electr geno parado y con el generador desconectado de la red el ctrica so pena de peligro grave para las personas y las cosas No utilizar nunca l quidos o agua No limpiar con aire comprimido las partes el ctricas interiores pues se podr a provocar cortocir cuitos u otras anomal as Servirse solamente de personal cualificado JB4 Dicembre 2003 Rev 01 69 ESPANOL 70 JB4 Dicembre 2003 Rev 01 Schemi elettrici Wiring diagrams Schaltpl ne Sch ma lectrique Esquemas el ctricos L1 U L3 W sensing N a o E Ai L1 L3 U w sensing m L3 W sensing 612 4 10 541 INN 312 U1 Vi w1 L2 L3 U w sensing AA PR U2 V2 a 2 6 2 sensing JB4 Dicembre 2003 Rev 01 71 Disegno esploso Exploded view Teilmontagezeichnung Vue eclat e Despiece JB4S JB4C 35 75kVA 72 JB4 Dicembre 2003 Rev 01 050790996 var avs bar AVS 19129 rar AVS 9490 5 Jap 94999 4909 yar AVS Br LL Z p selenopued so a njou LL 1 h Seseid sa puasdwog uayubaqu gp LL 2 P E AL x
40. maximum pr vue pour le g n rateur peut endommager ce dernier R glage de la sous vitesse 50 60 Hz porter le groupe en rotation en le r glant de mani re obtenir une fr quence de 46 56 Hz Tourner le trimmer UF jusqu au point o la tension commence baisser Reporter le groupe la vitesse nominale Attention r gler la sous vitesse une valeur de fr quence trop basse peut endommager le g n rateur Au contraire la r gler une valeur trop lev e peut causer des chutes de tension avec des charges lev es Raccordement d un potentiom tre ext rieur 5kOhm enlever le shunt sur les bornes EXT POT et connecter le potentiom tre aux extr mit s libres en veillant le positionner la valeur de r sistance maximum Tourner le trimmer V fond dans le sens contraire des aiguilles d une montre Porter le groupe la vitesse nominale et agir sur le potentiom tre jusqu la tension voulue Si des fluctuations de tension sous charge devaient se v rifier il est possible d agir sur le potentiom tre ST qui module la rapidit de r ponse du r gulateur aux stimulations ext rieures en permettant d liminer les ventuelles instabilit s du syst me alternateur charge 6 4 5 Sch mas de connexion pour diff rents circuits Nous fournissons en annexe au pr sent manuel des sch mas pour connexions diff rentes de la connexion toile s rie normalement effectu e en usine moins de
41. o mec nico sean realizadas por personal cualificado 7 ASISTENCIA Y MANTENIMIENTO Advertencia Las intervenciones de mantenimiento y localizaci n de aver as conllevan riesgos que podr an ocasionar graves lesiones personales o incluso la muerte Por tanto estas operaciones ser n realizadas nica y exclusivamente por personal habilitado a la asistencia el ctrica y mec nica Antes de ejecutar cualquier intervenci n de mantenimiento y de limpieza comprobar que las partes no est n bajo tensi n que la temperatura de la carcasa del generador sea ambiental que el grupo electr geno no pueda arrancar incluso accidentalmente y que todas las operaciones se realicen correctamente 7 1 Control de los devanados y de las condiciones de aislamiento Se puede comprobar el estado de los devanados midiendo su resistencia el ctrica hacia la masa Durante esta prueba estar desconectado el regulador de tensi n Normalmente es suficiente controlar s lo el devanado principal Los valores medidos deber n ser superiores a 2MOhm De resultar la resistencia de aislamiento inferior se proceder al secado del alternador en el horno a una temperatura comprendida entre 60 y 80 C por 3 horas Antes de llevar a cabo esta operaci n es necesario desmontar el regulador de tensi n Como alternativa al secado en horno es posible soplar aire caliente a 60 80 C a trav s del alternador al menos por 1 hora 7 2 Control de los cojinetes Los cojinetes
42. pr sente une pr cision de tension de 2 dans la plage de fonctionnement de la machine avec des charges non d formantes La tension de sortie peut tre r gl e l aide du trimmer V voir figure de 185 290V avec une tol rance de 10 Au moyen d un shunt suppl mentaire il est possible de porter la plage de variation de 220 320V toujours avec une tol rance de 10 Le r gulateur est muni d une protection de limitation d excitation en fonction de la fr quence le r glage de la fr quence s effectue l aide du trimmer UF le pr r glage a lieu 46Hz 1Hz Quand cette fr quence est atteinte la machine commence diminuer sa propre tension jusqu ce qu elle se d sexcite cause de fr quences tr s basses Un fusible prot ge le r gulateur et le g n rateur contre les ventuelles surcharges et ou pannes une poche sp ciale sur le bord de la carte contient un fusible de r serve fusible type 32x6 3 2 5A rapide Un autre trimmer ST permet d adapter le r gulateur aux param tres du g n rateur Le r gulateur a t construit pour limiter au minimum les pics de tension quand la charge est d branch e pics qui r sultent inf rieurs 20 avec la charge nominale 5 SP CIFICATIONS G N RALES M CANIQUES ET LECTRIQUES POUR ACCOUPLEMENT AVEC LE MOTEUR Dans la mesure o 1 s agit d une unit s par e et destin e tre incorpor e dans un groupe lec
43. ritornassero disassemblati o con targhette dati alterati o manomessi ITALIANO JB4 Dicembre 2003 Rev 01 15 ENGLISH 1 SAFETY RECOMMENDATIONS 2 CONFORMITY DECLARATION 2 1 Declaration of electromagnetic compatibility 3 INTRODUCTION 3 1 Control of ID plate 3 2 Position of plate with electrical specifications serial number and production lot 4 OPERATING PRINCIPLE AND CHARACTERISTICS OF THE VOLTAGE REGULATOR SYSTEM 4 1 AVR board 5 GENERAL MECHANICAL AND ELECTRICAL SPECIFICATIONS FOR COUPLING WITH MOTOR 6 INSTALLATION 6 1 Lifting 6 2 Mounting on motor 6 2 1 Assembly format SAE 6 2 2 Dismantling format SAE 6 3 Earthing 6 4 Preliminary Controls 6 4 1 Control of electrical insulation 6 4 2 Direction of rotation 6 4 3 Control of voltage and frequency 6 4 4 AVR board settings 6 4 5 Wiring diagrams for different circuits 6 4 6 Initial start up 7 AFTERSALES ASSISTANCE AND MAINTENANCE 7 1 Control of windings and electrical insulation 7 2 Control of bearings 7 3 Troubleshooting 7 4 Removal and replacement of components and component assemblies 7 4 1 Extracting and inserting the shaft 7 4 2 Changing bearing 7 4 3 Changing rotating diodes 7 4 4 Replacing components and component assemblies 8 CLEANING AND LUBRICATION 9 DISMANTLING AND DISPOSAL 10 SPARE PARTS AND AFTERSALES 10 1 Aftersales procedure and contact addresses 11 WARRANTY 16 JB4 Dicembre 2003 Rev Ol ENGLIS
44. sp cifications diff rentes au moment de la commande 6 4 6 Mise en service Avant la mise en service du groupe lectrog ne il faut v rifier que toutes les connexions ext rieures ont t effectu es correctement et que les protections Les ventuelles modifications de la connexion doivent tre effectu es exclusivement par du personnel qualifi AVERTISSEMENT Trimmer V EXT POT 115 Trimmer ST Attention R gler latension une valeur sup rieure la valeur maximum pr vue pour le g n rateur peut endommager ce dernier R gler la sous vitesse une valeur de fr quence trop basse peut endommager le g n rateur Au contraire la r gler une valeur trop lev e peut causer des chutes de tension avec des charges lev es JB4 Dicembre 2003 Rev 01 51 FRAN AIS AVERTISSEMENT AVERTISSEMENT DANGER Ne pas toucher le g n rateur pendant le fonctionnement et juste apr s l arr t du groupe dans la mesure o il pourrait y avoir des surfaces haute temp rature La carence d inspections et d entretien peut causer de graves dommages aux personnes et ou aux choses Les proc dures de maintenance et de localisation des pannes comportent des risques qui pourraient causer de graves l sions personnelles ou la mort Ces proc dures doivent donc tre effectu es exclusivement par du personnel qualifi pour effectuer l
45. with JB4 Dicembre 2003 Rev 01 27 DEUTSCH 1 SICHERHEITSNORMEN 2 KONFORMIT TSERKL RUNG 2 1 Erkl rung der elektromagnetischen Kompatibilit t 3 EINF HRUNG 3 1 Kontrolle des Typenschilds 3 2 Positionierung des Schilds mit den elektrischen Spezifikationen der Seriennummer und dem Produktionsauf trag 4 FUNKTIONSPRINZIP UND EIGENSCHAFTEN DES SPANNUNGSREGELUNGSSYSTEMS 4 1 AVR Karte 5 ALLGEMEINE MECHANISCHE UND ELEKTRISCHE SPEZIFIKATIONEN ZUR KOPPELUNG MIT DEM MOTOR 6 INSTALLIERUNG 6 1 Heben 6 2 Befestigung am Motor 6 2 1 Montage Form SAE 6 2 2 Demontage Form SAE 6 3 Erdung 6 4 Vorbereitende Kontrollen 6 4 1 Kontrolle der Isolierung 6 4 2 Drehrichtung 6 4 3 Uberprifung der Spannung und der Frequenz 6 4 4 Einstellung Karte AVR 6 4 5 Anschluss Schaltpl ne f r verschiedene Kreise 6 4 6 Inbetriebnahme 7 KUNDENDIENST UND WARTUNG 7 1 Kontrolle der Wicklungen und des Zustands der Isolierung 7 2 Kontrolle der Lager 7 3 Anomalien und Abhilfe 7 4 Entfernen und Auswechselung von Komponenten und Gruppen von Komponenten 7 4 1 Ausbau und Einbau der Welle 7 4 2 Auswechselung des Lagers 7 4 3 Auswechselung der rotierenden Dioden 7 4 4 Wiederzusammensetzung der Komponenten und Gruppen von Komponenten 8 REINIGUNG UND SCHMIERUNG 9 ABBAU UND ENTSORGUNG 10 ERSATZTEILE UND KUNDENDIENST 10 1 Verfahrensablauf und Adressen zur Bezugnahme bei Anforderung von Kundendienstleistungen 11 GARANTIE 28 JB4
46. 0G9 var Jouajue Ello var UEAE ajo Par 141 JONIO var Lzdi 911146 4 var 12 ebro LLLLOL98y var 1 opnosy var jueae saljonog var 01405 var PISIYS ory var uoisdu9s9q Bunqiaiyosag uondu19s8q 2 12590 WAXSOL 06 Wrar Olquieded ap sezald 9 51 119I230S13 3511 Sed aseds IP Wed JB4 Dicembre 2003 Rev 01 75 Cablaggio AVR AVR electric connections Anschluss AVR Connexion lectrique AVR Conexi n el ctrica AVR O 5 Green Auxiliary Green Auxiliary Red exc Black exc 3 3 91 21 O O ST O I V NE DA UF 0 E 28 7X H 7X Orange Sensing Orange Sensing EMC Filter Resistenze Resistances Widerstanden R sistance Resisten
47. 1 Die Generatoren Typ JB4 werden au erdem auf den folgenden Grundlagen geliefert Sie m ssen als Stromgeneratoren oder f r darauf bezogene Funktionen benutzt werden Sie m ssen auf eine der folgenden Einsatzweisen betrieben werden Tragbar ohne Verkleidung zur vor bergehenden Energielieferung Tragbar mit Verkleidung zur vor bergehenden Energielieferung An Bord unter Deck Anwendung auf See nach vorheriger Zulassung Auf Nutzfahrzeug Transport auf R dern K hlung etc Auf Schiene Hilfsenergie Auf Industriefahrzeug Erdbewegung Hebeger te etc Feste Installierung Industrie Werk Anlage Feste Installierung Wohnsektor Handel und Leichtindustrie Heim B ro Krankenhaus Energiesteueung Miterzeugung Stromaufnahmespitzen Alternative Energieschemata Die Standard Generatoren sind daf r konzipiert die industriellen Emissionen und die Immunit tsstandards zu erf llen Falls die Generatoren an Emissionsvorschriften f r Wohn Handels und Leichtindustrieber eiche gebunden sind k nnten sich einige zus tzliche Zubeh rteile als erforderlich erweisen Der Installierungsplan erfordert die Verbindung des Generatorgeh uses mit dem Erdunggsleiter wobei ein Kabel mit geeignetem Querschnitt und so geringer L nge wie m glich benutzt wird DEUTSCH Der Gebrauch von nicht den Original Ersatzteilen entsprechenden oder nicht ausdr cklich genehmigte
48. 991 var Jonajue var ajo var Led AHIO var Lzdi 911146 4 var esouejue enbuo 901101987 var 1 opnosy var jueae var 01405 var PISIYS ory var opnos uoisdu9s9q Bunqiaiyosag uondu19s8q 2 12590 I SE Spar OIQUIEIO Sold 9JSI I9ZIESAI 3911 Sed asedg Ip Hed JB4 Dicembre 2003 Rev 01 73 Disegno esploso Exploded view Teilmontagezeichnung Vue eclat e Despiece JB4M JB4L 90 105kVA 2 7 RK H 74 JB4 Dicembre 2003 Rev 01 050790996 var avs euedweo var AVS 197189 aJ91aAnoyg bar AVS 99019 Jap 949909 49A09 119Q par AVS 87 LL e so Sp LL L p sesard se usyubaqui gp LL 2 P E gy LL 2 sway 8p LL y e Uejoomed var Avs euedues olyoJadoy 560710991 1 193290 ounie 19109 apis 9 e 19 8 01y918d09 660710991 9309 Jap ne
49. COUPLING WITH MOTOR As an independent unit designed to be built into a electricity generating set it is impossible to apply all the signal decals on the generator during production These decals indicating a potential hazard or risk due to live components are supplied loose and have to be applied by the constructor of the electricity generating set in the positions indicated in the figure to the side once assembly of the whole set has been completed Caution The plate shows the phrase Nominal data refers to a star series connection and the connection effectively made should be clear ly marked by the installer on the connections list in order to avoid malfunctions and even damage to persons or objects For electrical circuits other than star series consult the section and specific wiring dia grams given in this manual AVR board Trimmer V Trimmer ST Trimmer UF JB4 Dicembre 2003 Rev 01 19 ENGLISH Ambient temp 40 Altitude m Power factor Important A drop in cooling air flow or inadequate pro tection of the generator can lead to damage and or malfunction of the windings 20 JB4 Dicembre 2003 Rev 01 The generators in the JB4 range are designed to operate at a maximum temperature of 40 C and at a maximum altitude above sea level of 1000m at s l The nominal performance indicated on the plate r
50. H 1 SAFETY RECOMMENDATIONS We thank you for having chosen a Sincro product and we are sure that it will satisfy all your expectations in high standards and performance The User and Maintenance Manual included with the generator provides important indications regarding safety installation use and maintenance This product complies with recognised standards in good engineering and provisions related to safety When contacting Sincro Srl always quote the generator type and code found on the label attached to the packing What s more in the event of malfunction or any other kind of machine fault that should require our Af tersales Service please specify the serial number SN and production order PO CAUTION An incorrect installation or improper use of the product may cause damage to persons and objects Strictly observe the instructions given in the User and Maintenance Manual that is provided to indicate the correct conditions for installation use and maintenance in order to prevent malfunctions in the generator and avoid hazardous situations for the user Dispose of all packing material i e plastic cardboard polystyrene etc according to statutory regulations Keep the instructions with the technical folder and for future consultation This product has been designed and constructed solely for the applications indicated in this manual Any use not specified in this manual may cause damage to the product and
51. LIGRO Important 66 JB4 Dicem De no llevarse a cabo inspecciones y mantenimiento se podr an ocasionar graves da os tanto a las personas como a las cosas Las intervenciones de mantenimiento y localizaci n de aver as conllevan riesgos que podr an ocasionar graves lesiones personales o incluso la muerte Por tanto estas operaciones ser n realizadas nica y exclusivamente por personal habilitado a la asistencia el ctrica y mec nica Antes de ejecutar cualquier intervenci n de mantenimiento y de limpieza comprobar que las partes no est n bajo tensi n que la temperatura de la carcasa del generador sea ambiental que el grupo electr geno no pueda arrancar incluso accidentalmente y que todas las Operaciones se realicen correctamente e La duraci n de los cojinetes depender en gran medida de las condiciones y del ambiente de trabajo Largos periodos de permanencia en un ambiente con vibraciones pueden estropear las bolas y los anillos de bolas Una humedad demasiado elevada puede ocasionar la emulsi n de la grasa y favorecer efectos de corrosi n bre 2003 Rev 01 el desmontaje de las protecciones y la desconexi n de los dispositivos de protecci n Advertencia De no llevarse a cabo inspecciones y mantenimiento se podr an ocasionar graves da os tanto a las personas como a las cosas Como consecuencia de todo esto se requiere que todas las operaciones de car cter el ctrico
52. Preliminary Controls 6 4 1 Control of electrical insulation Before starting up the electricity generating set or after long shutdowns check the insulation resistance of the windings to earth Caution Unhook the AVR voltage regulator before carrying out this test The results must be over 2MOhm If this is not the case the alternator alone should be oven dried at 60 80 C for 3 hours Before carrying out this op eration remove the voltage regulator As an alternative to oven drying hot air at 60 80 C can be blown through the alternator for at least 1 hour Important The windings are tested under high tension during pro duction Additional high tension tests can weaken the insulation thereby reducing the working lifespan If a high tension test should prove necessary for customer approval these tests should be carried out at lower voltages 6 4 2 Direction of rotation The machines in format SAE are fitted with a one way fan and are therefore only suitable for a clockwise rotation looking from the coupling side The machines in format B3 are fitted with a propeller fan and can therefore oper ate in both directions of rotations The generator is supplied with clockwise rotation viewed from the coupling side unless otherwise specified on order to produce a U V W phase sequence If rotation has to be reversed after delivery ask the Sincro Technical Office for the relevant wiring diagrams 6 4 3 Control of voltage and frequency Con
53. a maintenance lectrique et m canique S assurer avant toute op ration d entretien ou de nettoyage qu il n y a pas de parties sous tension que la carcasse du g n rateur est temp rature ambiante que le groupe lectrog ne ne peut pas tre mis en marche accidentellement et que toutes les proc dures sont effectu es correctement 52 JB4 Dicembre 2003 Rev Ol ont t enlev es Les diff rents r glages du g n rateur sont effectu s en usine au moment de l essai de fonctionnement il ne devrait donc pas tre n cessaire d effectuer d autres r glages sur la machine s il se r v le n cessaire d enlever les protections pour effectuer des r glages et qu on laisse d couverts des contacts sous tension veiller que ces op rations soient effectu es exclusivement par du personnel qualifi dans la maintenance d installations lectriques Au moment de la mise en service faire attention aux ventuels bruits anormaux qui pourraient indiquer un alignement incorrect entre le moteur et le g n rateur Avertissement Ne pas toucher le g n rateur pendant le fonctionnement et juste apr s l arr t du groupe dans la mesure o il pourrait y avoir des surfaces haute temp rature Les g n rateurs sont des machines lectriques rotatives qui pr sentent des parties potentiellement dangereuses dans la mesure o elles sont sous tension ou munies de mouvement pendant le fonctionnement par cons quent il est abso
54. ada y o una alineaci n incorrecta del generador pueden ocasionar lesiones personales ADVERTENCIA y o da os a los aparatos Comprobar que el procedimiento de puesta a tierra sea correcto Orificios roscados M10 para la puesta a tierra JB4 Dicembre 2003 Rev 01 63 ESPA OL Atenci n Desconectar el regulador de tensi n AVR antes de efectuar la medici n Importante Los devanados han sido comprobados ADVERTENCIA en alta tensi n durante la producci n M s pruebas con alta tensi n pueden deteriorar el aislamiento y por tanto reducir su vida operativa De ser necesaria una prueba con alta tensi n para la aceptaci n por parte del cliente se efectuar n las pruebas con niveles de tensi n reducidos El generador sale de las l neas de producci n con una conexi n estrella serie de no especificarse diversamente en el pedido respecto del cual se suministran los datos nominales En el caso de modificaci n de dicha conexi n el instalador se encargar de marcar la nueva conexi n indicada en la placa de datos m quina puesta en el interior de la caja de bornes Para realizar la nueva conexi n tener como referencia los esquemas que se adjuntan con el presente manual Las posibles modificaciones de la conexi n ser n realizadas nica y exclusivamente por personal cualificado 64 JB4 Dicembre 2003 Rev 01 6 4 Con
55. age e Check the rpm s Check the windings ENGLISH No load voltage too high Calibrate the voltage Change the regulator Under load voltage below nominal Calibrate the voltage e Current too high below 0 8 speed below 4 of nominal Change the regulator Check the diodes unhooking the cables Under load voltage above nominal Calibrate the voltage Change the regulator Unstable voltage Check for uniform rotation Control regulator stability by adjusting potentiometer ST For any other problem please contact the Sincro Aftersales service cen tre 7 4 Removal and replacement of components and component assem blies 7 4 1 Extracting and inserting the shaft The following procedures presume the alternator has been separated from the motor Dual bearing and cone version e Unscrew the 8 x M10 screws that fasten the shield to the spacer flange for SAE 2 version this is not necessary Hammer the shield evenly until it comes away from the rotor dual bearing version and from the spacer flange cone version Remove the back grille and hammer the back of the rotor so that the bearing comes free Sustain the rotor with a sling on the coupling side Continue to drive the rotor out of the stator gradually adapting the sling so that the winding is not damaged SAE single bearing version Unscrew the 8 x M10 screws that fasten the shield to th
56. aggio dello scudo 7 4 3 Sostituzione dei diodi rotanti Estrarre il rotore seguendo le istruzioni al paragrafo 7 4 1 e Scollegare il ponte diodi e Svitare le viti e togliere il ponte diodi e Rimontare il ponte diodi nuovo fissando le viti con del frenafiletti e collegare i terminali e Reinserire il rotore seguendo a ritroso le istruzioni fornite al paragrafo 74 1 Alternativamente possibile sostituire il ponte diodi smontando il solo scudo posteriore come gi descritto per la sostituzione del cuscinetto 7 4 4 Riassemblaggio di componenti e gruppi di componenti Per l operazione di riassemblaggio compiere le precedenti operazioni ese guite durante lo smontaggio a ritroso 8 PULIZIA E LUBRIFICAZIONE Avvertenza Qualunque tipo di intervento di pulizia deve essere ese guito con gruppo elettrogeno fermo e generatore scollegato dalla rete elettrica pena grave pericolo per persone e cose Accertatisi che il gruppo elettrogeno sia fermo e scollegato dalla rete elettrica il gruppo pu essere pulito esternamente con aria compressa Attenzione AVVERTENZA AVVERTENZA Preventivamente all estrazione del rotore orientare il rotore stesso in modo che durante il movimento di estrazione il rotore si appoggi al l interno dello statore mediante la scarpa polare Quando viene reinserito il rotore l alternatore pu perdere il magnetismo residuo che per mette l autoeccitazione Prima dell avviamento del gruppo
57. are la tensione ad un valore superiore a quello mas simo previsto per il generatore pu causare il danneggiamento del generatore stesso Regolazione della sottovelocit a 50 60 Hz portare il gruppo in rotazione regolandolo in modo da ottenere una frequenza di 46 56 Hz Ruotare il trim mer UF fino al punto in cui la tensione inizia a calare Riportare il gruppo alla velocit nominale Attenzione Regolare la sottovelocit ad un valore di frequenza troppo basso pu causare il danneggiamento del generatore stesso AI con trario regolandolo ad un valore troppo alto pu causare delle cadute di tensione con carichi elevati Collegamento di un potenziometro esterno 5kOhm rimuovere il ponti cello sui terminali EXT POT e collegare ai capi liberi il potenziometro avendo cura di posizionarlo al valore di massima resistenza Ruotare il trimmer V in senso antiorario fino alla posizione estrema Portare il gruppo alla velocit nominale e agire sul potenziometro fino alla tensione voluta Qualora si dovessero verificare delle fluttuazioni di tensione a carico pos sibile agire sul potenziometro ST che modula la prontezza di risposta del regolatore agli stimoli esterni permettendo di eliminare eventuali instabilit del sistema alternatore carico 6 4 5 Schemi di collegamento per diversi circuiti Allegati al presente manuale si trovano gli schemi per collegamenti diversi dal collegamento stella serie normalme
58. as a cabo con el alternador desconectado del motor Versi n de dos cojinetes y c nica e Extraer los 8 tornillos M10 que bloquean el escudo en la brida distanciadora no es necesario en la versi n SAE 2 e Golpear homog neamente el escudo hasta que se separe completamente del rotor versi n de dos cojinetes y de la brida distanciadora versi n c nica Desmontar la rejilla posterior y golpear el rotor posteriormente para empujar el cojinete fuera de su alojamiento Sostener el rotor con una eslinga por el lado de acoplamiento e Seguir empujando el rotor fuera del estator adaptando continuamente la posici n de la eslinga a fin de no estropear el devanado Versi n monocojinete SAE e Extraer los 8 tornillos M10 que bloquean el escudo en la brida distanciadora no es necesario en la versi n SAE 2 Importante Intensas vibraciones causadas por el motor o por una alineaci n err nea de los componentes del grupo electr geno someten el cojinete a esfuerzos que reducen su vida JB4 Dicembre 2003 Rev 01 67 ESPA OL Atenci n Antes de extraer el rotor orientarlo de forma tal que durante el movimiento de extracci n el rotor se apoye en el interior del estator mediante la zapata polar Al volver a montar el rotor el alternador puede perder el magnetismo residual que permite la autoexcitaci n Por tanto ADVERTENCIA antes de poner en marcha el grupo ser necesario volver a exci
59. ate et ou un alignement erron L installation l utilisation la maintenance ou le remplacement de pi ces effectu s de mani re erron e peuvent tre la cause de AVERTISSEMENT graves l sions personnelles ou de mort ainsi que de dommages aux quipements Les interventions sur les parties lectriques et ou m caniques doivent tre effectu es par du personnel qualifi Attention Une capacit de levage insuffisante peut causer des l sions personnelles et de gra ves dommages Les anneaux de levage pr sents sur le g n rateur ont t r alis s pour soulever uniquement le g n rateur et non pas tout le groupe lectrog ne Attention Avant le montage v rifier que les si ges d accouplement tant du g n rateur que du moteur sont r guliers et propres Une protection inad quate et ou un alignement erron du g n rateur peuvent tre la cause de l sions personnelles et AVERTISSEMENT ou de dommages l quipement JB4 Dicembre 2003 Rev 01 49 FRAN AIS A AVERTISSEMENT S assurer que la mise la terre est effectu e correctement Attention D connecter le r gulateur de tension AVR avant de proc der la mesure Trous filet s M10 pour la mise
60. atore nelle posizioni indicate in figura Importante Una riduzione del flusso dell aria di raffredda AVVERTENZA AVVERTENZA mento o un inadeguata protezione del generatore possono comportare il danneggiamento e o il malfunzionamento degli avvolgimenti Il generatore viene fornito senza alcun colle gamento a massa per il collegamento si dovr fare riferimento alle corrispondenti disposizioni locali Collegamenti a massa o di protezione eseguiti in modo errato possono essere causa di lesioni o di decesso Una installazione uso manutenzione o sostitu zione di parti eseguite in modo errato possono essere causa di gravi lesioni personali o di decesso nonch di danneggiamento delle attrezzature Gli interventi sulle parti elettriche e meccaniche devono essere eseguiti da per sonale qualificato JB4 Dicembre 2003 Rev 01 7 ITALIANO Attenzione Una capacit di sollevamento non adatta pud causare lesioni personali e gravi danni Gli anelli di sollevamento presenti sul generatore sono stati realizzati per il sollevamento del solo generatore e non dell intero gruppo elettrogeno Attenzione Prima del montaggio verificare che le sedi di accoppiamento sia del generatore che del motore siano regolari e ben pulite Una protezione ina
61. avant l installation ou comme 1 1 0 93 0 88 r serve il est conseill d utiliser des r sistances anticondensation pour garantir la bonne conservation des enroulements Avant la mise en service ou apr s de longues p riodes d inactivit il faut contr ler la r sistance d isolement vers la masse de tous les enroulements nous recommandons de d connecter le r gulateur de tension avant de JB4 Dicembre 2003 Rev 01 47 FRAN AIS Important Une r duction du flux de l air de refroidissement ou une protection inad quate du g n rateur peuvent entra ner Pendommagement et ou le mauvais fonctionnement des enroulements Le g n rateur est fourni sans aucune connexion la terre pour l effectuer il faudra se r f rer aux normes locales AVERTISSEMENT n Vigueur Des mises la terre ou des connexions de protection effectu es de mani re erron e peuvent tre cause de l sions ou de mort 48 JB4 Dicembre 2003 Rev 01 proc der cet essai les valeurs mesur es doivent tre sup rieures 2MOhm Si ce n est pas le cas il faut proc der au s chage au four de l alternateur uniquement 60 80 C pendant 3 heures Avant d effectuer cette op ration il faut enlever le r gulateur de tension En alternative au s chage au four il est possible de souffler de chaud travers l alternateur 60 80 C pendant au moins 1 heure En cas d installation sous capot ferm il faud
62. azione in forno possibile soffiare attraverso l alternatore aria calda 60 80 C per almeno 1 7 2 Controllo dei cuscinetti I cuscinetti sono sigillati ed esenti da manutenzione Durante la manutenzione controllare lo stato dei cuscinetti e verificare che non siano presenti perdite di grasso la durata dei cuscinetti dipende dalle vibrazioni e dai carichi assiali ai quali sono sottoposti le vibrazioni possono essere notevolmente amplificate nel caso di un errato allineamento e dalle condizioni di lavoro Verificare quindi che non vi siano anomalie come vibrazioni rumori insoliti uscite d aria ostruite Se dopo un certo periodo di tempo dovessero manifestarsi eccessi di vibra zione o rumorosit queste potrebbero essere dovute all usura del cuscinetto che se danneggiato deve essere sostituito Il cuscinetto comunque consigliabile sia sostituito dopo 20 000 ore di funzionamento I cuscinetti dei generatori azionati con trasmissione a cinghia essendo soggetti a carichi superiori a quelli dei generatori azionati con accoppiamento diretto hanno una vita normalmente inferiore e andranno sostitui ti dopo 15 000 ore di funzionamento Importante La durata dei cuscinetti fortemente influenzata dalle condizioni e dall ambiente di lavoro Importante Lunghi periodi di permanenza in un ambiente caratterizzato dalla presenza di vibrazioni possono danneggiare le sfere e le sedi di rotolamento La presenza di una umidi
63. capacity of at least 400kg Caution An insufficient loadbearing capacity can cause severe injury and damage Caution The lifting lugs on the generator have been designed for lifting only the generator and not the whole electricity generating set When lifting and handling single bearing generators they must be kept hori zontal in order to avoid if operations should go wrong the rotor from slipping out and being damaged and possibly causing severe injury 6 2 Mounting on motor 6 2 1 Assembly format SAE see figure Caution Before proceeding with assembly check that the couplings both on generator and motor are in order and perfectly clean Remove the rotor anchor bar Remove the protective grilles 6 and plastic lids 7 on the bell Make sure the diameter of the disk 3 corresponds with the diameter of the seat in the flywheel 2 Anchor the generator to the motor by locking the SAE bell 1 making sure that the holes in disk and flywheel are aligned Check that the disk is in contact with the flywheel by hammering axially the rotor with a plastic mallet and block Lock the disk onto the flywheel Check that the exciter rotor and stator are perfectly aligned e Mount the assembly on antivibration plugs 5 making sure that motor and generator are level Replace the grilles and lids 6 2 2 Dismantling format SAE For dismantling follow in reverse the instructions provided in section 6 2 1 War
64. ccaggio della campana SAE 1 controllando la corrispondenza dei fori del disco con quelli del volano e Verificare che il disco sia in appoggio sul volano colpendo assialmente il rotore con un martello in plastica e un tampone Fissare il disco al volano e Verificare che il rotore e lo statore dell eccitatrice siano perfettamente allineati fra loro Supportare il gruppo con antivibranti 5 curando il corretto livellamento tra motore e generatore Rimontare le griglie e i coperchi 6 2 2 Smontaggio forma SAE Per lo smontaggio seguire a ritroso le istruzioni fornite al paragrafo 6 2 1 Avvertenza Una protezione inadeguata e o un allineamento errato del generatore possono essere causa di lesioni personali e o di danneg giamento dell attrezzatura 6 3 Messa a terra La carcassa del generatore deve essere solidamente collegata a massa sul basamento del gruppo elettrogeno Se sono previsti dei supporti flessibili antivibranti tra la carcassa del generatore ed il suo basamento si dovr collegare in parallelo attraverso il supporto flessibile un conduttore di terra di valore nominale adeguato solitamente la met dell area della sezione trasversale dei cavi della linea principale Sullo scudo posteriore in corrispondenza dei piedi sono stati predisposti due fori filettati M10 per facilitare la messa a terra della cassa vedi figura a lato Avvertenza Accertarsi della correttezza della procedura di messa a terra
65. cias Ohm Tipo Type Typ Type Tipo Statore Stator Stator Stator Estator Ausiliario Auxiliary Erregung Excitation Excitaci n Rotore Rotor Rotor Rotor Rotor Statore eccitatrice Exciter stator Erreger stator Stator excitatrice Estator excitatriz Rotore eccitatrice Exciter rotor Erreger Rotor Rotor excitatrice Rotor excitatriz JB4SA 0 46 4 15 1 10 JB4SB 0 33 3 85 1 18 JB4SC 0 24 3 75 1 30 JB4CA 0 18 3 44 1 47 JB4CB 0 14 3 22 1559 JB4MA 0 10 3 07 1 77 JB4LA 0 08 2 98 1199 76 JB4 Dicembre 2003 Rev 01 Centri di assistenza autorizzati italiani Italian Sincro service centers Veneto SINCRO S r l Via Tezze 3 36073 Cereda di Cornedo Vic no Vicenza Tel 0445 450500 Fax 0445 446222 e mail info sincro com Sicilia Denaro G B 4 C S n c Via G Matteotti 382 97017 Vittoria Ragusa Tel 0932 981686 Fax 0932 987520 Elettromeccanica Oddo Sebastiano Via Asmara 98076 S Agata Militello Messina Tel 0941 701171 Fax 0941 723066 Puglia Basilicata Molise Euromotor B G Str Prov Mariotto 9 e 13 E 70038 Terlizzi Bari Tel 080 3514204 Fax 080 3512941 Campania Calabria Candileno Domenico amp Figli S n c Via Garibaldi 22 80026 Casoria Napoli Tel 081 7596424 Fax 081 5842662 Emilia Romagna Elettro Multi Serv
66. d to the earth conductor using an adequately sized cable with a minimum length possible The use of any spare parts that are not genuine or not expressly authorised shall free Sincro from any warranty liability and any responsibility concerning conformity to regulations and relevant consequences Installation aftersales assistance and maintenance must be carried out by adequately trained staff with a knowledge of the provisions of EC di rectives 3 INTRODUCTION On delivery inspect the generator to check it has not been damaged during transport or that no parts are missing 3 1 Control of ID plate The generators in the JB4 range can be identified by their ID plate This should be controlled and checked against the order specifications on delivery in order to ascertain eventual errors in shipment or configuration 3 2 Position of plate with electrical specifications serial number and production lot An adhesive plate is supplied with the generator indicating its serial number SN which is different for each machine and the production lot PO The plate must be applied by the installer in the position indicated in the figure so that it is easy to read in effect the serial number and production lot play an essential role in the procedures involved in requesting aftersales assistance The generator is supplied complete with an additional adhesive plate that gives the machine data and electrical specifications and a list of possible c
67. deguata e o un allineamento errato del generatore possono essere causa di lesioni personali e o di danneggiamento del AVVERTENZA Pattrezzatura Accertarsi della correttezza della procedura di messa a terra AVVERTENZA 8 JB4 Dicembre 2003 Rev 01 Per sollevare il generatore utilizzare dispositivi che abbiano una capa cit di sollevamento di almeno 400kg Attenzione Una capacit di sollevamento non adatta pu causare lesioni personali e gravi danni Attenzione Gli anelli di sollevamento presenti sul generatore sono stati realizzati per il sollevamento del solo generatore e non dell intero gruppo elettrogeno Il sollevamento e la movimentazione dei generatori monocuscinetto devono essere eseguiti mantenendo la macchina in posizione orizzontale al fine di evitare se l operazione non fosse eseguita correttamente la fuoriuscita del rotore con possibile danneggiamento dello stesso e gravi conseguenze per le persone 6 2 Fissaggio al motore 6 2 1 Montaggio forma SAE vedi figure a lato Attenzione Prima del montaggio verificare che le sedi di accoppia mento sia del generatore che del motore siano regolari e ben pulite Togliere la barra di fissaggio del rotore Togliere le griglie di protezione 6 e i coperchi in plastica 7 posti sulla campana e Controllare che il diametro del disco 3 corrisponda al diametro di allog giamento nel volano 2 Fissare il generatore al motore mediante il blo
68. ducci n del caudal de aire de enfriamiento como una protecci n no adecuada del generador pueden conlle ADVERTENCIA var da os y o malfuncionamiento de los devanados Se suministra el generador sin conexi n de tierra para efectuar dicha conexi n se tendr n como referencia las correspondientes disposiciones locales Conexiones de tierra o de protecci n ejecutadas incorrectamente pueden ocasionar lesiones o incluso la muerte Tanto la instalaci n como el uso mantenimiento o sustituci n de piezas efectuados de manera incorrecta pueden ocasionar graves lesiones personales o incluso la muerte as como da os a los aparatos Los trabajos en las partes el ctricas y o mec nicas ser n realizados por personal cualificado 62 JB4 Dicembre 2003 Rev 01 estructura estar dise ada de forma tal que deje un espacio libre de 50mm entre la toma de aire del generador y cualquier otra superficie plana De estar especificado en el pedido se podr dotar el generador con filtros de aire Importante Tanto la reducci n del caudal de aire de enfriamiento como una protecci n no adecuada del generador pueden conllevar da os ylo malfuncionamiento de los devanados El grupo rotor del generador se equilibra din micamente en la f brica con chaveta entera versi n bicojinete Las vibraciones inducidas por el motor son complejas e incluyen arm nicos de orden superior que pueden ocasionar al combinarse con los del
69. e nominale Remplacer le r gulateur e Contr ler les diodes en d connectant les c bles Sous charge tension sup rieure la tension nominale e R gler de nouveau la tension e Remplacer le r gulateur Tension instable e Contr ler l uniformit de rotation Regler la stabilit du r gulateur en agissant sur le potentiom tre ST Pour toute autre anomalie s adresser au centre SAV Sincro Important La dur e des roulements est fortement influenc e par les conditions et le milieu de travail De longs s jours dans un environnement caract ris par la pr sence de vibrations peuvent endommager les billes et les si ges de roulement La pr sence d une humidit trop lev e peut causer l emulsion de la graisse et favoriser la corrosion Des vibrations intenses caus es par le moteur ou par un alignement incorrect des composants du groupe lectrog ne soumettent le roulement des sollicitations qui en r duisent la dur e de vie JB4 Dicembre 2003 Rev 01 53 FRAN AIS Attention Avant d extraire le rotor l orienter de ma ni re que durant le mouvement d extraction le rotor s appuie l int rieur du stator par l interm diaire de la corne polaire Quand le rotor est remis en place l alternateur peut perdre le magn tisme r siduel qui permet l auto excitation Avant la mise en AVERTISSEMENT Marche du groupe il faut donc r exciter Palternateur en
70. e podrian ocasionar dafos al producto o lesiones a la persona Simbolo con signo de admiraci n se ala situaciones de riesgo procedimientos peligrosos que podr an ocasionar graves lesiones a la persona o incluso la muerte Simbolo con rayo se ala situaciones de riesgo o procedimientos peligrosos que ocasionan graves lesiones a la persona o incluso la muerte 2 DECLARACI N DE CONFORMIDAD Todos los generadores JB4 se entregan con una declaraci n de incorporaci n conforme a la legislaci n europea como la que aparece en la ltima p gina del presente manual Seg n la Directiva M quinas CE es responsabilidad del Fabricante del grupo electr geno comprobar que los n meros de serie y de identificaci n del generador aparezcan en la cubierta de este manual 2 1 Declaraci n de Compatibilidad electromagn tica Los generadores JB4 est n construidos con criterios y materiales que certifican su compatibilidad con las siguientes Directivas europeas CEE 73 23 CEE 89 336 98 37 CE y modificaciones siguientes de las normas CEI 2 3 EN 60034 1 EN 55011 EN 50081 1 EN 50082 1 Asimismo los generadores tipo JB4 se suministran sobre las siguientes bases Ser n utilizados como generadores de potencia o funci n relativa Ser n utilizados en uno de los siguientes contextos Transportable sin estructura para el suministro de energ a temporal Transportable con estructura para el suministro de energ a temporal
71. e spacer flange for SAE 2 version this is not necessary e Remove the back grille and hit the back of the rotor so that the bearing comes free Sustain the rotor with a sling on the coupling side Continue to drive the rotor out of the stator gradually adapting the sling so that the winding is not damaged Insert the shaft following in reverse the instructions at section 7 4 1 Caution Before extracting the rotor turn it so that during extraction the rotor rests on the pole shoe while inside the stator Warning When the rotor is repositioned the alternator may loose the residual magnetism that enables it to self excite Before starting up the generating set the alternator will therefore have to be excited by applying a 6 12 volt current across the exciter terminals for a second respecting the polarities 7 4 2 Changing bearing See section 7 4 1 Remove the snap ring e Remove the bearing or bearings using a standard extractor Caution WARNING Before extracting the rotor turn it so that during extraction the rotor rests on the pole shoe while inside the stator When the rotor is repositioned the alter nator may loose the residual magnetism that enables it to self excite Before starting up the generating set the alter nator will therefore have to be excited by applying a 6 12 volt current across the exciter terminals for a second respecting the polarities JB4 Dicembre 2003 Rev 01 25
72. efers to operation within these temperature and altitude limits At temperatures over 40 C and or altitudes above 1000m at s l a loss of performance should be expected see table on the left The Sincro Technical Office should be advised of any environmental con ditions that worsen the above limits The generators are fitted with an air ventilation system protective guards and drip proof covers they are not suitable for outdoor installation unless an adequate protective shelter is provided When under storage awaiting installation or in standby it is advisable to use of anticondensate heaters to protect the windings from damp Before the initial start up or after long shutdowns check the insulation resist ance towards earth of all windings always remember to unhook the voltage regulator before carrying out this test the results must be over 2MOhm If this is not the case the alternator alone should be oven dried at 60 80 C for 3 hours Before carrying out this operation remove the voltage regulator As an alternative to oven drying hot air at 60 80 C can be blown through the alternator for at least 1 hour In the event of installation inside a closed housing make sure that the cooling air temperature for the generator does not rise above standard The housing must be constructed so that the motor air vent in the housing is separate from the generator air vent especially if the air inlet in the housing has to be supplied by the
73. eitung als Anlage zur technischen Akte und f r k nftige Konsultationen aufbewahren Dieses Produkt wurde ausschlie lich zum in dieser Dokumentation angegebenen Gebrauch konzipiert und hergestellt Ein in dieser Dokumentation nicht genannter Gebrauch k nnte Sch den am Produkt bewirken und eine Gefahrenquelle darstellen e Die Firma Sincro S r l lehnt jegliche Verantwortlichkeit die sich aus einem unsachgem en oder vom vorgesehenen in der vorliegenden Dokumentation genannten Zweck abweichenden Gebrauch ergibt ab e Das Produkt darf nicht in potentiell explosiver Atmosph re installiert werden Die Konstruktionselemente der Anlage m ssen den Europ ischen Richtlinien entsprechen F r alle L nder au erhalb der EWG empfiehlt es sich im Hinblick auf ein gutes Sicherheitsniveau au er den geltenden nationalen Vorschriften auch die oben genannten Normen zu beachten Die Installierung muss den Vorschriften der Europ ischen Richtlinien entsprechen und darf ausschlie lich von Fachpersonal ausgef hrt werden e Den Generator nicht starten wenn die Schutzkappen die Zugangsplatten oder die Abdeckplatten des Endverschlusskastens entfernt wurden Vor Ausf hrung irgendwelcher Wartungsarbeiten die Anlasserkreise des Motors deaktivieren Die Schlie kreise deaktivieren und oder Hinweisschilder auf jedem automatischen Schalter anbringen der normalerweise zum Anschlu an die Netzleitung oder andere Generatoren benutzt wi
74. em Ausbau des Rotors den Rotor selbst so ausrichten dass er wahrend der Auszugsbewegung im Innern des Stators aufliegt mittels des Polschuhs JB4 Dicembre 2003 Rev 01 39 DEUTSCH HINWEIS HINWEIS Beim Wiedereinbau des Rotors kann der Drehstromgenerator den Restmagnetismus der die Selbsterregung erm glicht verlie ren Vor dem Start des Aggregats ist es daher erforderlich den Drehstromgenerator neu zu erregen wobei an den Klemmen des Erregers eine Sekunde lang eine Spannung von 6 12 Volt angewandt wird unter Einhaltung der Polung Jede Art von Reinigungseingriff muss bei stillstehendem Elektro Aggregat und von der elektrischen Netzleitung abgetrenntem Generator ausgefiihrt werden da sonst gro e Gefahr f r Personen und Sachgegenst nde besteht 40 JB4 Dicembre 2003 Rev 01 Warnhinweis Beim Wiedereinbau des Rotors kann der Drehstromgenerator den Restmagnetismus der die Selbsterregung erm glicht verlieren Vor dem Start des Aggregats ist es daher erforderlich den Drehstromgenerator neu zu erregen wobei an den Klemmen des Erregers eine Sekunde lang eine Spannung von 6 12 Volt angewandt wird unter Einhaltung der Polung 7 4 2 Auswechselung des Lagers Auf den Absatz 7 4 1 Bezug nehmen Den elastischen Seegerring entfernen Das oder die Lager mittels gew hnlicher Ausziehwerkzeuge entfernen e Das neue bzw die neuen Lager nehmen und mittels eines Heizger ts erhitz
75. ement par du personnel qualifi 6 4 4 R glage carte AVR Pour choisir les r glages du dispositif de commande AVR acc der la carte de contr le apr s avoir enlev les protections La plupart des r glages sont effectu s en usine sur des valeurs destin es assurer des r sultats satisfaisants dans les essais de fonctionnement initiaux II pourrait se r v ler n cessaire d effectuer d autres r glages pour assurer un fonctionnement optimal dans des conditions de service sp cifiques Si l alternateur doit fonctionner 50Hz le shunt qui court circuite les bornes rep r e par 60Hz doit rester connect s il doit fonctionner 60Hz le shunt doit tre enlev Il est possible de modifier la tension de sortie en agissant sur le potentiom tre V Avec le groupe en marche la vitesse nominale r gler jusqu l obtention de la valeur cherch e Si une petite variation de vitesse la tension varie il faut alors r gler d abord la protection de sous vitesse La r f rence de tension c bles orange doit tre connect e e aux bornes 0 et 115 si l on pr l ve une tension entre 100 et 140V r glage effectu en usine aux bornes 0 et 230 si l on pr l ve une tension entre 200 et 280V Pour augmenter de 15 environ la gamme de tensions disponibles utiliser la borne Pa au lieu de la borne 0 Attention r gler la tension une valeur sup rieure la valeur
76. en damit der Durchmesser vor der Einf gung in den Sitz der Welle gedehnt wird Den Seegerring wieder montieren Den Rotor wieder einbauen wobei die unter Absatz 7 4 1 beschriebenen Anweisungen umgekehrt ausgef hrt werden Alternativ hierzu besteht die M glichkeit das Lager auszuwechseln ohne den Rotor auszubauen Die 4 Schrauben die den hinteren Schild am Geh use befestigen aufschrauben Gleichm ig auf den Schild klopfen bis zur vollst ndigen Abl sung vom Rotor Den elastischen Seegerring entfernen Das Lager mittels gew hnlicher Ausziehwerkzeuge entfernen e Das neue Lager nehmen und mittels eines Heizger ts erhitzen damit der Durchmesser vor der Einf gung in den Sitz der Welle gedehnt wird Den Seegerring wieder montieren Den Schild positionieren ohne dabei den elastischen Ring zu vergessen und die Befestigungsschrauben teilweise einf hren Gleichm ig auf den Schild klopfen bis zur vollst ndigen Einf hrung des Lagers und des Geh useteils in die entsprechenden Sitze Die Befestigungsschrauben des Schilds anziehen 7 4 3 Auswechselung der rotierenden Dioden Den Rotor unter Einhaltung der unter Absatz 7 4 1 gegebenen Anweisungen ausbauen Die Diodenbr cke abtrennen Die Schrauben aufschrauben und die Diodenbr cke entfernen Die neue Diodenbr cke montieren wobei die Schrauben mittels Gewindeklebers befestigt wird und den Verbinder sowie die 2 Faston ansch
77. eparada y destinada a ser incorporada en un grupo electr geno no es posible aplicar en la fase de construcci n todas las necesarias etiquetas de se alizaci n en el generador Las etiquetas de indicaci n de peligro potencial y riesgo debido a componentes en tensi n se suministran por separado y ser n aplicadas por el Fabricante del grupo electr geno en las posiciones indicadas en la figura de al lado una vez ultimado el ensamblaje del grupo Los generadores de la gama JB4 han sido dise ados para funcionar a una temperatura m xima de 40 C y a una cota m xima de 1000m s n m Dentro de tales l mites de temperatura y cota estos aparatos alcanzar n las prestaciones nominales indicadas en la placa Para temperaturas superiores a 40 C y o cotas superiores a 1000m s n m se manifiestan reducciones de prestaciones ver tabla De ser las condiciones ambientales de funcionamiento peores a las indicadas anteriormente se avisar de ello al Departamento T cnico Sincro Los generadores est n provistos de sistema de ventilaci n por aire escudos de protecci n y carcasas antigoteo no son aptos para ser instalados al aire libre de no estar protegidos por recubrimiento adecuado Mientr s est n depositado en el almac n antes de la instalaci n o si funciona de reserva es conveniente utilizar calentadores anticondensaci n para garantizar la buena conservaci n de los devanados Antes de la puesta en servicio o tras largos periodos de inac
78. er Ausf hrung zu schweren Verletzungen von Personen oder zum Tod sowie auch zu Besch digung der Ausr stungen f hren Die Eingriffe an elektrischen und oder mechanischen Teilen m ssen von Fachpersonal ausgef hrt Eine nicht geeignete Hebekapazit t kann zu Verletzungen von Personen und schweren Sch den f hren Die am Generator vorhandenen Heberinge wurden nur zum Heben des Generators und nicht des gesamten Elektro Aggregats vor gesehen Vor der Montage berpr fen dass die Kup plungssitze sowohl des Generators als auch des Motors einwandfrei und sauber sind zum ZZ 34 JB4 Dicembre 2003 Rev Ol Im Innern des Klemmenkastens befinden sich die isolierten Endverschl sse f r die Netzleitungs und Nulleiter Anschl sse sowie f r den Erdungsanschluss Der Nulleiter ist NICHT an das Geh use angeschlossen Warnhinweis Der Generator wird ohne irgendeinen Erdungsanschluss geliefert Zum Anschluss muss auf die entsprechenden vor Ort geltenden Vorschriften Bezug genommen werden Falsch ausgef hrte Erdungen oder Schutzschaltungen k nnen zu Verletzungen oder zum Tod f hren Die Fehlerstrom Werte des Generators sind auf Anfrage verf gbar um dem Planer bei der Bemessung der Anlage und ihrer Komponenten behilflich zu sein Warnhinweis Die Installierung der Geb
79. erf llt die Garantie Die zu Lasten der Firma Sincro erfolgenden Eingriffe m ssen in deren Werk ausgef hrt werden Alle Kosten in Bezug auf den Transport des zu reparierenden Produkts gehen zu Lasten des Kunden Die Garantie verf llt wenn Probleme oder St rungen auftreten die auf Unerfahrenheit oder Gebrauch ber die Grenzwerte der Nennleistungen hinaus beruhen bzw wenn das Produkt abge ndert wurde oder wenn die Drehstromgeneratoren in zerlegtem Zustand oder mit ver nderten oder besch digten Typenschildern zur ckkehren sollten HINWEIS Unter keinen Umst nden Fl ssigkeiten oder Wasser verwenden Die inneren elektrischen Teile nicht mit Druckluft reinigen da sonst Kurzschluss oder andere Anomalien auftreten k nnten Ausschlie lich Fachpersonal zu Rate ziehen JB4 Dicembre 2003 Rev 01 41 DEUTSCH 42 JB4 Dicembre 2003 Rev 01 FRAN AIS 1 NORMES DE S CURIT 2 D CLARATION DE CONFORMIT 2 1 D claration de Compatibilit lectromagn tique 3 INTRODUCTION 3 1 Contr le de la plaque signal tique 3 2 Positionnement de la plaque avec les donn es lectriques le num ro de s rie et l ordre de production 4 PRINCIPE DE FONCTIONNEMENT ET CARACT RISTIQUES DU SYST ME DE R GULATION DE LA TENSION 4 1 Carte AVR 5 SP CIFICATIONS G N RALES M CANIQUES ET LECTRIQUES POUR ACCOUPLEMENT AVEC LE MOTEUR 6 INSTALLATION 6 1 Levage 6 2 Fixation au moteur 6 2 1 Montage f
80. ersales Service provides a comprehensive technical advise service When requesting assistance under warranty make sure that the generator identification data is on hand including its serial number and production lot ENGLISH as shown on the adhesive label whose position is given in section 3 2 of this manual The list of authorised aftersales assistance centres can be found on our homepage www sogagroup com 11 WARRANTY Sincro s r l guarantees the quality safety and reliability of all its products The warranty covers faults and malfunctions arising from defects in con struction and materials for a period of 12 months from the date of delivery The warranty period cannot be extended for any reason even ifthe alternator still has not been commissioned In the event that material construction or assembly defects should appear during the warranty period Sincro s r l shall repair or replace free of charge the defective parts in as short a time as possible A warranty claim shall only be valid if made within 8 days from its discovery All work under warranty shall be carried out by Sincro in their factory All costs related to transport shall be covered by the customer The warranty shall be no longer valid should problems or faults arise due to undue care operation beyond the nominal performance limits if the product is modified or if the alternators are returned in a dismantled state or their ID plates have been altered or tampered
81. es c bles de la ligne principale Sur le bouclier arri re au niveau des pieds on a pr vu deux trous filet s M10 pour faciliter la mise la terre du bo tier Avertissement S assurer que la mise la terre est effectu e correctement 6 4 Contr les pr liminaires 6 4 1 Contr le de l isolement Avant la mise en service du groupe lectrog ne ou apr s de longues p riodes d inactivit contr ler la r sistance d isolement vers la masse des enroulements Attention D connecter le r gulateur de tension AVR avant de proc der la mesure Les valeurs mesur es doivent tre sup rieures 2MOhm Si la r sistance d isolement est inf rieure il faut proc der au s chage au four de l alternateur uniquement une temp rature comprise entre 60 et 80 C pendant 3 heures Avant d effectuer cette op ration il faut enlever le r gulateur de tension En alternative au s chage au four il est possible de souffler de l air chaud travers l alternateur 60 80 C pendant au moins 1 heure Important Les enroulements ont t test s haute tension durant la production D autres essais haute tension peuvent d t riorer l isolement et donc r duire la dur e de vie du composant Si un essai haute tension est n cessaire pour l acceptation de la part du client les essais devront tre effectu s des niveaux de tension r duits 6 4 2 Sens de rotation Les machines avec construction SAE sont munies de
82. est n sellados y no necesitan mantenimiento Durante el mantenimiento controlar el estado de los cojinetes y comprobar que no se den p rdidas de grasa la duraci n de los cojinetes depende de las vibraciones de las cargas axiales a las que est n sometidos las vibraciones pueden amplificarse considerablemente en el caso de una alineaci n err nea y de las condiciones de trabajo Por tanto comprobar que no haya anomal as como vibraciones ruidos ins litos y salidas de aire obstruidas De verificarse al cabo de cierto periodo de tiempo excesos de vibraciones de ruido la causa podr a ser el desgaste del cojinete que ser sustituido de estar estropeado De cualquier modo es aconsejable sustituir el cojinete al cabo de 20 000 horas de funcionamiento Como los cojinetes de los generadores accionados con transmisi n de correa est n sujetos a cargas superiores a las de los generadores accionados con acoplamiento directo normalmente su vida es inferior y por tanto se sustituir n despu s de 15 000 horas de funcionamiento Importante La duraci n de los cojinetes depender en gran medida de las condiciones y del ambiente de trabajo Importante Largos periodos de permanencia en un ambiente con vibraciones pueden estropear las bolas y los anillos de bolas Una humedad demasiado elevada puede ocasionar la emulsi n de la grasa y favorecer efectos de corrosi n ESPANOL Importante Intensas vibraciones causadas p
83. evront tre effectu es son usine Tous les frais relatifs au transport du produit r parer sont la charge du client La garantie perdra effet si les inconv nients ou les pannes qui se v rifient sont dus l inexp rience l utilisation au del des limites des performances nominales si le produit a subi des modifications ou si les alternateurs sont retourn s d mont s ou avec les plaquettes des donn es alt r es ou modifi es ESPANOL 1 NORMAS DE SEGURIDAD 2 DECLARACION DE CONFORMIDAD 2 1 Declaraci n de Compatibilidad electromagn tica 3 INTRODUCCI N 3 1 Control de la placa de caracter sticas 3 2 Posicionamiento de la placa con las especificaciones el ctricas el n mero de serie y de la orden de produc ci n 4 PRINCIPIO DI FUNCIONAMIENTO Y CARACTER STICAS DEL SISTEMA DE REGULACI N DE LA TENSI N 4 1 Tarjeta AVR 5 ESPECIFICACIONES GENERALES MEC NICAS Y EL CTRICAS PARA EL ACOPLAMIENTO CON EL MOTOR 6 INSTALACI N 6 1 Izado 6 2 Fijaci n al motor 6 2 1 Montaje forma SAE 6 2 2 Desmontaje forma SAE 6 3 Puesta a tierra 6 4 Controles preliminares 6 4 1 Control del aislamiento 6 4 2 Sentido de rotaci n 6 4 3 Verificaci n de tensi n y de frecuencia 6 4 4 Regulaci n de la tarjeta AVR 6 4 5 Esquemas de conexi n para distintos circuitos 6 4 6 Puesta en marcha 7 ASISTENCIA Y MANTENIMIENTO 7 1 Control de los devanados y de las condiciones de aislamiento 7 2 Control de los cojinetes
84. f rieure il faut proc der au s chage au four de l alternateur uniquement une temp rature comprise entre 60 et 80 C pendant 3 heures Avant d effectuer cette op ration il faut enlever le r gulateur de tension En alternative au s chage au four il est possible de souffler de l air chaud travers l alternateur 60 80 C pendant au moins 1 heure 7 2 Contr le des roulements Les roulements sont tanches et ne n cessitent pas d entretien Durant la maintenance contr ler l tat des roulements et v rifier qu il n y a pas de fuites de graisse la dur e des roulements d pend des vibrations et des charges axiales auxquelles ils sont soumis les vibrations peuvent tre consid rablement amplifi es en cas d alignement erron et des conditions de travail V rifier ensuite qu il n y a pas d anomalies telles que vibrations bruits insolites sorties d air bouch es Si au bout d un certain temps le fonctionnement entra ne des vibrations ou FRAN AIS des bruits excessifs cela pourrait tre d l usure du roulement qui doit tre remplac s il est endommag ll est conseill dans tous les cas de remplacer le roulement au bout de 20 000 heures de fonctionnement Les roulements des g n rateurs actionn s par une transmission courroie tant sujets des charges sup rieures celles des g n rateurs actionn s par accouplement direct ont une vie normalement inf rieure et devront tre
85. gen Abdeckungen zu entfernen und man unter Spannung stehende Kontakte frei liegen l sst wird dringend empfohlen diese Arbeiten nur durch f r die Wartung elektrischer Anlagen qualifiziertes Personal ausf hren zu lassen Bei der Inbetriebnahme auf eventuelle anomale Ger usche achten die auf eine nicht korrekte Fluchtung zwischen Motor und Generator hinweisen k nnten Warnhinweis Den Generator w hrend des Betriebs und sofort nach dem Anhalten des Aggregats nicht ber hren da die Oberfl chen hohe Temperaturen aufweisen k nnten Generatoren sind elektrische Rotationsmaschinen die potentiell gef hrliche Teile aufweisen da diese w hrend des Betriebs unter Spannung gesetzt oder mit Bewegung ausgestattet werden Absolut verboten sind daher unsachgem er Gebrauch das Entfernen der Schutzabdeckungen und das Abtrennen der Schutzvorrichtungen Warnhinweis Der Mangel an Inspektionen und Wartung kann zu schweren Personen und oder Sachsch den f hren Als Konsequenz der obigen Ausf hrungen wird verlangt dass jeder Arbeitsvorgang elektrischer oder mechanischer Art von Fachpersonal vorgenommen wird 7 KUNDENDIENST UND WARTUNG Warnhinweis Die Arbeitsabl ufe zur Wartung und Lokalisierung von St rungen bringen Risiken mit sich die zu schweren Verletzungen von Personen oder Todesf llen f hren k nnten Diese Arbeitsabl ufe d rfen daher ausschlie lich von zur elektrischen und mechanischen Assistenz bef higtem Per
86. generador niveles de vibraci n sensibles y perjudiciales para el funcionamiento del grupo electr geno Por tanto el proyectista utilizar las soluciones necesarias para la alineaci n asi como dar rigidez a las bases y a los soportes con el prop sito de impedir que se superen los niveles de vibraci n previstos en las normas Los generadores de dos cojinetes requieren una carcasa r gida para el sost n del motor generador de forma que constituya una buena base para la exacta alineaci n La carcasa estar unida a la base con tampones antivibraciones Con el fin de reducir al m nimo las oscilaciones torsionales es conveniente utilizar una junta flexible dimensionada correctamente En los sistemas de transmisi n de correa aplicados a generadores de dos cojinetes es necesario que tanto el di metro como la estructura de las poleas sean tales que permitan que la carga aplicada al eje est centrada respecto del largo de la parte sobresaliente y que no sea superior a 4000N Para larguras del eje mayores se requerir n directamente al Departamento T cnico Sincro los valores de carga admitidos La alineaci n de los generadores monocojinete es cr tica dado que podr an producirse vibraciones a la altura del acoplamiento entre el motor y el generador As ser necesario tener cuidado al ensamblar el alternador al motor y disponer una base robusta y el uso de tampones antivibraciones para sostener el conjunto motor alternador
87. geraten Bei den bei Zweilager Generatoren angewandten Riemen bertragungssy stemen m ssen der Durchmesser und die Struktur der Riemenscheiben so bemessen ein dass sie zulassen dass die an der Welle angewandte Last in Bezug auf die L nge des berstands zentriert wird und 4000N nicht berschreitet Bei l ngeren Wellen k nnen die zul ssigen Lastwerte direkt beim Technischen B ro der Firma Sincro angefragt werden Die Fluchtung der Einlager Generatoren ist kritisch weil auf der H he der Kupplung zwischen Motor und Generator Vibrationen entstehen k nnten Aus diesem Grund muss die Montage des Drehstromgenerators an den Motor sorgf ltig ausgef hrt und ein solides Untergestell sowie der Einsatz von Vibrationsd mpfer Puffern vorgesehen werden um das Gesamtgebilde Motor Drehstromgenerator zu st tzen Wichtig Eine Reduzierung des Flusses der K hlluft oder ein unzureichender Schutz des Gene rators k nnen zu Besch digung und oder zu Funktionsst rungen der Wick lungen f hren JB4 Dicembre 2003 Rev 01 33 DEUTSCH HINWEIS Achtung Achtung Der Generator wird ohne irgendeinen Erdungsanschluss geliefert Zum Anschluss muss auf die entsprechenden vor Ort geltenden Vorschriften Bezug genommen werden Falsch ausgef hrte Erdungen oder Schutzschaltungen k nnen zu Verletzungen oder zum Tod f hren Die Installierung der Gebrauch die Wartung oder die Auswechselung von Teilen k nnen bei falsch
88. groupe lectrog ne arr t et le g n rateur d branch sous peine d exposer les personnes et les choses un grave danger S assurer que le groupe lectrog ne est arr t et d branch le groupe peut tre nettoy ext rieurement l air comprim Avertissement N utiliser en aucun cas des liquides ou de l eau Ne pas nettoyer l air comprim les parties lectriques internes car cela pourrait provoquer des courts circuits ou d autres anomalies 9 D MOLITION ET MISE AU REBUT Avertissement Faire appel exclusivement du personnel qualifi L limination des mat riaux doit tre faite dans le respect des normes en vigueur En cas de d molition du g n rateur il n existe pas de risques particuliers ou de dangers d rivant du g n rateur proprement dit Il est opportun en cas de recyclage des mat riaux qu ils soient s par s par type parties lectriques cuivre aluminium plastique etc 10 PI CES DE RECHANGE ET SERVICE APR S VENTE 10 1 Proc dure et adresses de r f rence pour demandes de service apr s vente Notre Service Apr s Vente fournit un conseil technique complet S assurer pour les demandes de Service Apr s Vente sous garantie de disposer des donn es d identification du g n rateur de son num ro de s rie et du num ro de l ordre de production indiqu s sur l tiquette autocollante positionn e comme l indique le paragraphe 3 2 de ce manuel La liste des centres apr s vente
89. i tutti gli avvolgimenti si raccomanda di scollegare il regolatore di tensione prima di procedere con tale prova i valori rilevati devono essere maggiori di 2MOhm Nel caso non sussista tale condizione si deve procedere all essiccazione in forno del solo alternatore a 60 80 C per 3 ore Prima di eseguire tale operazione occorre rimuovere il regolatore di tensione In alternativa allessiccazione in forno possibile soffiare attraverso l alternatore aria calda 60 80 C per almeno 1 ora In caso di installazione all interno di una cappottatura chiusa ci si dovr assi curare che la temperatura dell aria di raffreddamento inviata nel generatore non superi quella nominale prevista La cappottatura deve essere realizzata in modo che la presa d aria del motore nella cappottatura sia separata da quella del generatore soprattutto se l aspirazione d aria nella cappottatura deve essere assicurata dalla ventola di raffreddamento La presa d aria del generatore inoltre dovr essere realizzata in modo da impedire infiltrazioni di umidit prevedendo un filtro adeguato La cappottatura dovr essere progettata in modo tale da lasciare tra la presa d aria del generatore e qualsiasi superficie piana una ITALIANO luce minima di 50 mm Se specificato all atto dell ordine il generatore pu essere dotato di filtri dell aria Importante Una riduzione del flusso dell aria di raffreddamento o un inadeguata protezio
90. icas se entrega por separado para poder colocarla en el generador en la posici n indicada en la figura despu s de haberlo pintado de ser necesario La superficie para fijarla estar lisa limpia y con la pintura completamente seca Para el montaje correcto de la placa quitar el papel que la protege por cerca de 20mm y pegarla en el sitio indicado luego seguir quitando el papel de protecci n poco a poco presionando la placa en su sitio Al cabo de 24 horas la adhesi n ser perfecta 4 PRINCIPIO DI FUNCIONAMIENTO Y CARACTER STICAS DEL SISTEMA DE REGULACI N DE LA TENSI N Gracias a su magnetismo residual el estator de la excitatriz garantiza la autoexcitaci n del generador al ponerse en marcha lo que genera por lo tanto una tensi n residuall de aprox el 10 de la tensi n nominal El AVR alimentado a trav s de un circuito auxiliar montado en el estator principal acciona el estator de la excitatriz regulando indirectamente mediante la cadena del rotor de esta puente de diodos rotor principal el campo generado por el rotor principal El control de tensi n regula el valor medio de la tensi n de una fase manteni ndola constante Un dispositivo de control de la frecuencia interviene desexcitando progresivamente la m quina cuando la velocidad del motor de tracci n desciende por debajo del umbral establecido regulable impidiendo la sobreexci taci n con reg menes bajos de funcionamiento y aliviando el efecto de toma de ca
91. ice S r l Via Spagnoli 3 29010 Sarmato Piacenza Tel 0523 886202 Fax 0523 886172 e mail info elettromultiservice com F lli Cesari S n c Via dei Caligari 4 40129 Bologna Tel 051 322221 Fax 051 4189595 Lazio Bruno Chiossi Via A Pulcinelli 6 01032 Caprarola Viterbo Tel 0761 647656 Sardegna Elettro Meccanica dei F lli Brai di amp A S n c Via Ginevra Zona Industriale Nord 09170 Oristano Tel 0783 357008 359939 Fax 0783 357008 359939 Valle d Aosta Officina Elettromeccanica Menegolo G 8 C S n c Loc Plan Felinaz 73 11020 Charvensod Aosta Tel 0165 44144 Fax 0165 232539 JB4 Dicembre 2003 Rev 01 77 Centri di assistenza autorizzati nel mondo Worldwide Sincro service centers United Kingdom Sogagroup UK Ltd Bill Hall The Manor House Puttenham Heath Rd Puttenham Surrey GU 3 1A9 England GB Ph 0044 148 3813227 Fax 0044 8452803122 E mail franciscradock sogagroup co uk Albania Cema Sh Pk Rr Kavajes Ish Kombinati Tekstil Fabrika Ngjyrosjes Tirana Ph 355 4352562 Fax 355 4352562 E mail cema icc al org Canada Canimex Inc 285 St Georges J2C 4H3 Drummondville Quebec CANADA Ph 001 819 4771335 Fax 001 819 4770306 Grecia Exan Via Kapetan Agra 62 57009 Kalohori Salonicco Greece Ph 0030 2310753860 Fax 0030 2310753928 E mail exansa acn gr U S A Getec Incorporated 624 Harris Road 12734 Ferndale
92. indem ein geeigneter Filter vorgesehen wird Die Verkleidung muss so geplant werden dass zwischen der Ansaug ffnung des Generators und irgendwelchen Planfl chen ein Freiraum von mindestens 50mm besteht Falls dies bei Auftragserteilung spezifiziert wird kann der Generator mit Luftfiltern ausgestattet werden Wichtig Eine Reduzierung des Flusses der K hlluft oder ein unzureichender Schutz des Generators k nnen zu Besch digung und oder zu Funktionsst rungen der Wicklungen f hren Das Rotoraggregat des Generators wird im Werk mit Vollkeil dynamisch ausgewuchtet Zweilager Version Die vom Motor bewirkten Vibrationen sind komplex und schlie en starke harmonische Schwingungen mit ein die in Verbindung mit denen des Generators zu sp rbaren und f r die Funktion des Elektro Aggregats sch dlichen Vibrationspegeln f hren k nnen Es ist daher Aufgabe des Planers die erforderlichen Vorkehrungen zu treffen um die Fluchtung zu pflegen und das Untergestell und die St tzen zu versteifen damit die berschreitung der von den Normen vorgesehenen Vibrationsgrenzen vermieden wird Zweilager Generatoren erfordern einen steifen Rahmen zur Abst tzung des Motors Generators so dass eine gute Basis f r eine exakte Fluchtung gebildet wird Dieser Rahmen muss mittels Vibrationsd mpfer Puffern am Untergestell befestigt werden Um die Drehschwingungen auf ein Minimum zu reduzieren wird zur Benutzung einer korrekt bemessenen elastischen Kupplung
93. iori regolazioni per assicurare un funzionamento ottimale in specifiche condizioni d esercizio Se l alternatore deve funzionare 50Hz il ponticello che cortocircuita i termi nali contrassegnati da 60Hz deve rimanere collegato se deve funzionare a 60Hz il ponticello deve essere rimosso possibile modificare la tensione di uscita agendo sul potenziometro V Con il gruppo in moto alla velocit nominale regolare fino ad ottenere il Fori M10 per messa a terra Attenzione Scollegare il regolatore di tensione AVR prima di procedere alla misurazione Importante Gli avvolgimenti sono stati collaudati in alta AVVERTENZA tensione durante la produzione Ulteriori prove in alta tensione possono deteriorare l isolamento e quindi ridurre la vita operativa Se si rendesse necessario un collaudo in alta tensione per l ac cettazione da parte del cliente le prove dovranno essere condotte a livelli di tensione ridotti Il generatore esce dalle linee di produzione con un collegamento stella serie a meno di specifiche diverse all atto dell ordine rispetto al quale vengono forniti i dati nominali com pito dell installatore in caso di successiva modifica di tale collegamento contrassegnare il nuovo collegamento usato sulla targhetta dei dati macchina presente all interno della scatola morsettiera Per effettuare il nuovo collegamento avvalersi degli
94. isiko Situationen oder gef hrliche Verfahrensabl ufe die Sch den am Produkt oder an den angeschlossenen Apparaten verursachen k nnten Achtung Bezieht sich auf Risiko Situationen oder gef hrliche Verfahrensabl ufe die Sch den am Produkt oder Verletzungen der Person verursachen k nnten Symbol mit Ausrufezeichen Bezieht sich auf Risiko Situationen oder gef hrliche Verfahrensabl ufe die schwere Verletzungen der Person oder deren Tod verursachen K NNTEN Symbol mit Blitz Das Symbol weist auf Risiko Situationen oder gef hrliche Verfahrensabl ufe hin die schwere Verletzungen der Person oder deren Tod verursachen 2 KONFORMIT TSERKL RUNG Alle Generatoren JB4 werden in bereinstimmung mit der europ ischen Gesetzgebung mit einer Erkl rung zur Eingliederung in eine Gesamtanlage geliefert die der auf den letzten Seiten der vorliegenden Bedienungsanleitung dargelegten entspricht Gem der EG Maschinen Richtlinie ist der Hersteller des Elektro Aggregats daf r verantwortlich sicherzustellen dass die Serien und Kennnummer des Generators auf dem Deckblatt dieser Bedienungsanleitung angegeben werden 2 1 Erkl rung der elektromagnetischen Kompatibilit t Die Generatoren JB4 werden mit Kriterien und Materialien hergestellt die die Kompatibilit t mit den folgenden europ ischen Richtlinien bescheinigen EWG 73 23 EWG 89 336 98 37 EG und sp tere Ab nderungen Normen CEI 2 3 EN 60034 1 EN 55011 EN 50081 1 EN 50082
95. it du b ti et des supports pour viter le d passement des limites de vibration pr vues par les normes Les g n rateurs double roulement n cessitent un ch ssis rigide pour le soutien du moteur g n rateur de mani re constituer une bonne base pour un alignement correct Ce ch ssis devra tre li au b ti au moyen de tampons antivibrants Pour r duire au minimum les sollicitations de torsion il est conseill d utiliser un accouplement flexible correctement dimensionn Dans les syst mes d entra nement par courroie appliqu s des g n rateurs double roulement il faut que le diam tre et la structure des poulies soient tels qu ils permettent que la charge appliqu e l arbre soit centr e par rapport la longueur du bout de l arbre et ne d passe pas 4000N Pour des longueurs d arbre sup rieures les valeurs de charge admissibles pourront tre demand es directement au Service Technique Sincro L alignement des g n rateurs un seul roulement est critique car des vibrations pourraient se v rifier au niveau de l accouplement entre moteur et g n rateur Pour l viter il faut veiller l assemblage de l alternateur au moteur pr voir un b ti solide et l emploi de tampons antivibrants pour soutenir le groupe moteur alternateur l int rieur de la bo te bornes se trouvent les bornes isol es pour les connexions de ligne et de neutre et pour la mise la terre Le neutre N EST PAS connect
96. it des Schleppmotors unter eine vorher festgelegte einstellbare Schwelle sinkt wodurch eine bererregung bei niedriger Drehzahl verhindert und der Effekt des Lastanstiegs am Motor erleichtert wird Abschlie end ist es auch m glich die Reaktionsbereitschaft des Reglers zu modulieren um eventuell auftretende Spannungsschwankungen zu eliminieren 4 1 AVR Karte Der Spannungsregler der Serie JB4 weist eine Spannungspr zision von 2 im Wirkungsbereich der Maschine bei nicht verdrehenden Lasten auf Die Ausgangsspannung kann ber den Trimmer V siehe Abbildung von 185 bis 290V reguliert werden mit einer Toleranz von 10 Mittels einer zus tzlichen Br cke kann der Regelbereich auf 220 bis 320V gebracht werden stets mit einer Toleranz von 10 Der Regler ist mit einem Erregungsbegrenzungsschutz je nach Frequenz ausgestattet Die Eichung der Frequenz erfolgt ber den Trimmer UF die Voreichung erfolgt auf 46Hz 1Hz Bei Erreichen dieser Frequenz beginnt die Maschine ihre eigene Spannung zu vermindern bis sie sich wegen sehr niedriger Frequenzen aberregt Eine Sicherung sch tzt den Regler und den Generator vor eventuellen berlasten und oder Defekten Eine entsprechende am Rand der Karte ausgearbeitete Tasche enth lt eine Ersatzsicherung flinke Sicherung Typ 32x6 3 2 5A Ein weiterer Trimmer ST erm glicht die Anpassung des Reglers an die Parameter des Generators Der Regler wurde konstruiert um die Spannungsspitzen bei Ent
97. iteren Klebeschild geliefert auf dem die elektrischen Daten und Spezifikationen und die Liste der m glichen Anschl sse angegeben sind Achtung Das Schild tr gt die folgende Aufschrift Die Nenndaten beziehen sich auf Stern Serienschaltung und der effektiv realisierte Anschluss muss seitens des Installateurs unter den in der Liste enthaltenen klar markiert werden um m gliche Funktionsst rungen und eventuelle Personen oder Sachsch den zu vermeiden Achtung Zur Vorbereitung von Stromkreisen die von der Stern ISerienschaltung abweichen m ssen der entsprechende Abschnitt und die spezifischen Schaltpl ne die nachstehend in dieser Bedienungsanleitung enthalten sind konsultiert werden Das Technische B ro der Firma Sincro steht f r alle eventuellen Erl uterungen zur Verf gung Das Datenschild wird in losem Zustand geliefert damit es nach der eventuellen Lackierung in der in der Abbildung gezeigten Position auf dem Generator angebracht werden kann Die Befestigungsfl che muss glatt und sauber sein nach vollst ndiger Trocknung des Lacks Zur korrekten Anbringung das Schutzpapier ca 20 mm weit abziehen Nachdem dieser Teil positioniert und angeklebt wurde kann das Schutzpapier nach und nach abgezogen werden w hrend das Schild in Position gedr ckt wird Die perfekte Anhaftung wird nach 24 Stunden erzielt 4 FUNKTIONSPRINZIP UND EIGENSCHAFTEN DES SPANNUNGSRE GELUNGSSYSTEMS Der Erreger Stator garantiert dank seine
98. itionn e et adh re au support le papier de protection peut tre progressivement enlev et la plaquette press e en position L adh rence parfaite s obtient au bout de 24 heures 4 PRINCIPE DE FONCTIONNEMENT ET CARACT RISTIQUES DU SYST ME DE R GULATION DE LA TENSION Le stator de l excitatrice gr ce son magn tisme r siduel garantit l auto excitation du g n rateur au d marrage qui g n re par cons quent une tension r siduelle gale environ 10 de la tension nominale L AVR aliment par un circuit auxiliaire pr sent sur le stator principal agit sur le stator de l excitatrice en r gulant indirectement travers la cha ne rotor excitatrice pont de diodes rotor principal le champ g n r par le rotor principal Le contr le de tension r gule la valeur moyenne de la tension d une phase en la maintenant constante FRAN AIS Un dispositif de contr le de la fr quence intervient en d sexcitant progressivement la machine quand la vitesse du moteur d entra nement descend en dessous d un seuil pr fix et r glable en emp chant une Trimmer V surexcitation aux bas r gimes de fonctionnement et en all geant l effet de prise de charge sur le moteur Trimmer ST Trimmer UF Il est enfin possible de moduler la rapidit de r ponse du r gulateur afin d liminer les ventuelles instabilit s de tension qui pourraient se manifester 4 1 Carte AVR Le r gulateur de tension de la s rie JB4
99. jando descubiertos los contactos en tensi n se recomienda que dichas operaciones sean llevadas a cabo nica y exclusivamente por personal encargado del mantenimiento de instalaciones el ctricas Al poner en marcha la m quina prestar atenci n a posibles ruidos an malos pues podr an se alar una alineaci n no correcta entre el motor y el generador Advertencia No tocar el generador durante su funcionamiento ni al pararse el grupo pues la temperatura de algunas de las superficies podr a ser elevada Los generadores son m quinas el ctricas rotatorias con partes potencialmente peligrosas ya que est n bajo tensi n o dotadas de movimiento durante el funcionamiento por tanto est terminantemente prohibido e el uso impropio Trimmer V EXT POT 115 Trimmer ST Atenci n Regular la tensi n con un valor superior al m ximo previsto para el generador puede ocasionar da os a ste Regular la subvelocidad con un valor de frecuencia demasiado bajo puede ocasionar da os al generador Al contrario si se regula con un valor demasiado alto puede ocasionar ca das de tensi n con cargas elevadas No tocar el generador durante su funcionamiento ni al pararse el grupo pues la temperatura de algunas de las ADVERTENcIA SUPerficies podr a ser elevada JB4 Dicembre 2003 Rev 01 65 ESPA OL A ADVERTENCIA A ADVERTENCIA iPE
100. keit die Ausgangsspannung durch Einwirkung auf das Potentiometer V abzu ndern Mit bei Nenndrehzahl laufendem Aggregat regeln bis der gesuchte Wert erreicht ist Wenn sich die Spannung bei einer geringf gigen Drehzahlver nderung ndert muss zuerst der Unterdrehzahlschutz eingestellt werden Der Spannungs Bezugspunkt orangefarbene Kabel muss wie folgt angeschlossen sein an die Klemmen 0 und 115 wenn eine Spannung zwischen 100 und 140V entnommen wird Einstellung im Werk an die Klemmen 0 und 230 wenn eine Spannung zwischen 200 und 280V entnommen wird Um die Palette der verf gbaren Spannungen um ca 15 zu erweitern die Klemme Pa anstatt der Klemme 0 benutzen Achtung Die Einstellung der Spannung auf einen Wert der ber dem f r den Generator vorgesehenen H chstwert liegt kann die Besch digung des Generators selbst bewirken Einstellung der Unterdrehzahl auf 50 60 Hz Das Aggregat in Rotation versetzen und so einstellen dass man eine Frequenz von 46 56 Hz erh lt Den Trimmer UF bis zu dem Punkt drehen an dem die Spannung abzufallen beginnt Das Aggregat auf Nenndrehzahl zur ckfahren Achtung Die Einstellung der Unterdrehzahl auf einen zu niedrigen Frequenzwert kann die Besch digung des Generators selbst bewirken Andererseits kann die Einstellung auf einen zu hohen Wert zu Spannungsabfall mit hohen Lasten f hren DEUTSCH Anschluss eines exte
101. kungen gesch tzt werden W hrend der Verweilzeit im Lager vor der Installierung DEUTSCH bzw als Reserve wird zum Gebrauch von Antikondensierungs Heizelementen geraten um eine gute Bewahrung der Wicklungen zu gew hrleisten Vor der Inbetriebnahme oder nach langen Stillstandzeiten muss der Isoli erungswiderstand zur Erde aller Wicklungen kontrolliert werden es wird darauf verwiesen dass der Spannungsregler vor Ausf hrung dieser Pr fung abgetrennt werden muss Die ermittelten Werte m ssen ber 2MOhm liegen Falls dies nicht der Fall ist muss eine Trocknung des Drehstromgenerators allein im Ofen bei 60 80 C ber 3 Stunden vorgenommen werden Vor Ausf hrung dieses Arbeitsvorgangs den Spannungsregler entfernen Als Alternative zur Trocknung im Ofen besteht die M glichkeit mindestens 1 Stunde lang Hei luft durch den Drehstromgenerator zu blasen bei 60 80 C Bei Installierung im Innern einer geschlossenen Verkleidung muss man sich vergewissern dass die Temperatur der in den Generator eingeblasenen K hlluft den vorgesehenen Nennwert nicht berschreitet Die Verkleidung muss so ausgef hrt werden dass die Ansaug ffnung des Motors in der Verkleidung von der des Generators getrennt ist vor allem wenn die Luftansaugung in der Verkleidung vom L fterrad zur K hlung gew hrleistet werden muss Die Ansaug ffnung des Generators muss au erdem so realisiert werden dass das Eindringen von Feuchtigkeit verhindert wird
102. l rt werden Les generateurs objets de la pr sente d claration doivent tre consid r s comme tant des composants En cons quence la mise en service de ces derniers est interdite avant la mise en conformit des machines auxquelles ils seront incorpor s Les dites machines devront tre d clar es confor mes aux directives regardant Los generatores objeto de la presente declaraci n han de entenderse como componen tes por lo tanto se prohibe su puesta en servicio antes de que las m quinas a las cuales se acoplar n no se declaren conformes a las normas sobre seguridad CEE 89 392 art 4 anexo 2 letra B CEE 91 368 art 1 y sobre compatibilidad la s curit CEE 89 392 art 4 electromagn tica annexe 2 lettre B CEE 91 368 art 1 et la compatibilit lectro magn tique Sincro S r l L Amministratore Delegato The Managing Director Delegierter des Verwaltungsrats L administrateur d l gu El Administrador Delegado Flavio MEE Pistollato JB4 Dicembre 2003 Rev 01 79 SINCRO srl via Tezze 3 36073 Cereda di Cornedo Vicentino Vicenza Italia tel 39 0445 450500 fax 39 0445 446222 e mail sales sincro sogagroup com web www sogagroup com Sincro srl si riserva il diritto di modificare i dati per aggiornare o migliorare i propri prodotti senza alcun preawiso Sincro srl reserves the right to change the data in order to update or improve ts products witho
103. la Baja Ten si n del 19 de Febrero del 1973 73 23 CEE introducida en ltalia con la ley n 791 del 18 de Octubre del 1977 2 la Norma 89 336 CEE y sucesiva modificaci n 93 68 CEE sobre la compatibilidad electromagn tica La prueba de compatibilidad se ha realizado en base a las siguientes normas EN 55011 110 6 EN 50081 1 110 7 EN 50082 2 110 8 generatori oggetto della pre sente dichiarazione sono da intendersi come componenti pertanto vige il divieto dimessa in servizio prima che le mac chine in cui saranno incorporati siano dichiarate conformi alle direttive riguardanti la sicurezza CEE 89 392 art 4 allegato 2 lettera B CEE 91 368 art 1 e la compatibilit elettromagnetica Cereda di Cornedo li 25 6 2003 The generators covered by this certificate must be considered as components and therefore prohibited from being placed in operation before the machine in which they will be used has been certificated for conformity to safety directives EEC 89 392 art 4 point 2 letter B EEC 91 368 art 1 and for electromagnetic compatibility Die Generatoren Gegenstand dieser Erkl rung sind als Komponenten zu verstehen daher ist ihre Inbetriebnahme verboten bevor nicht die Ma schinen in die sie integriert werden mit den Richtlinien bez glich Sicherheit CEE 89 392 Art 4 Anlage 2 Buchstabe B CEE 91 368 Art 1 und elektrischer Kompatibilit t f r konform erk
104. las mismas instrucciones indicadas en el apartado 6 2 1 pero en secuencia inversa Advertencia Una protecci n inadecuada y o una alineaci n incorrecta del generador pueden ocasionar lesiones personales y o da os a los aparatos 6 3 Puesta a tierra La carcasa del generador estar conectada s lidamente a tierra en la base del grupo electr geno De estar previstos soportes flexibles antivibraciones entre la carcasa del generador y su base se conectar en paralelo a trav s del soporte flexible un cable de tierra de valor nominal adecuado generalmente la mitad del rea de la secci n transversal de los cables de la l nea principal Han sido predispuestos en el escudo posterior a la altura de los pies dos orificios roscados M10 para facilitar la puesta a tierra de la caja Advertencia Comprobar que el procedimiento de puesta a tierra sea correcto Atenci n Una capacidad de izada no adecuada pue de ocasionar lesiones personales y da os graves Los anillos para izar del generador est n destinados exclusivamente para el izado de dicho aparato y no del entero grupo electr geno Atenci n Antes del montaje verificar que los alojamientos de acoplamiento tanto del generador como del motor sean regulares y est n bien limpios Una protecci n inadecu
105. lastung die mit Nennlast unter 20 liegen auf einem Minimum zu halten 5 ALLGEMEINE MECHANISCHE UNDELEKTRISCHE SPEZIFIKATIONEN ZUR KOPPELUNG MIT DEM MOTOR Nachdem es sich um eine separate zur Eingliederung in ein Elektro Aggregat vorgesehene Einheit handelt ist es nicht m glich in der Konstruktionsphase alle erforderlichen Hinweis Etiketten auf dem Generator anzubringen Diese Etiketten die auf potentielle Gefahr und Risiken aufgrund von unter Spannung stehenden Komponenten hinweisen werden in losem Zustand geliefert wobei der Hersteller des Elektro Aggregats f r die Anbringung in den in der nebenstehenden Abbildung gezeigten Positionen Sorge tragen muss sobald die Montage des Aggregats abgeschlossen ist Die Generatoren der Produktreihe JB4 sind zum Betrieb bei einer H chsttemperatur von 40 C und in einer H henlage von max 1000 d M konzipiert Innerhalb dieser Temperatur und H hengrenzen liefern sie die auf dem Typenschild angegebenen Nennleistungen Bei Temperaturen ber 40 C und oder H henlagen von ber 1000 m d M machen sich Leistungsverminderungen bemerkbar siehe Tabelle Es ist angebracht den Betrieb unter schlechteren Umweltbedingungen als den vorstehend genannten dem Technischen B ro der Firma Sincro zu melden Die Generatoren sind mit Bel ftungssystem Schutzschirmen und nichttropfenden Geh usen ausgestattet Sie sind nicht zur Installierung im Freien geeignet au er wenn sie durch entsprechende Abdec
106. lie en Den Rotor wieder einbauen wobei die unter Absatz 7 4 1 gegebenen Anweisungen umgekehrt ausgef hrt werden Alternativ hierzu besteht die M glichkeit die Diodenbr cke auszuwechseln indem nur der hintere Schild demontiert wird wie bereits bei der Auswechselung des Lagers beschrieben 7 4 4 Wiederzusammensetzung der Komponenten und Gruppen von Komponenten Zur Wiederzusammensetzung werden die vorher bei der Demontage ausgef hrten Arbeitsvorg nge umgekehrt vorgenommen 8 REINIGUNG UND SCHMIERUNG Warnhinweis Jede Art von Reinigungseingriff muss bei stillstehendem Elektro Aggregat und von der elektrischen Netzleitung abgetrenntem Generator ausgef hrt werden da sonst gro e Gefahr f r Personen und Sachgegenst nde besteht DEUTSCH Sicherstellen dass das Elektro Aggregat stillsteht und von der elektrischen Netzleitung abgetrennt ist Das Aggregat kann au en mit Druckluft gereinigt werden Warnhinweis Unter keinen Umst nden Fl ssigkeiten oder Wasser verwenden Die inneren elektrischen Teile nicht mit Druckluft reinigen da sonst Kurzschluss oder andere Anomalien auftreten k nnten 9 ABBAU UND ENTSORGUNG Warnhinweis Ausschlie lich Fachpersonal zu Rate ziehen Die Entsorgung der Materialien muss unter Einhaltung der geltenden Normen erfolgen Beim Abbau des Generators bestehen keine besonderen Risiken oder Gefahren die sich aus dem Generator selbst ableiten Bei Recycling der Materialien ist es a
107. lisation et la maintenance du g n rateur e Tout ce qui n est pas express ment pr vu dans ces instructions n est pas permis FRAN AIS Dans ce manuel sont utilis s des symboles et des signes conventionnels qui ont une signification pr cise Ils sont d finis ci apr s de mani re univoque Important Se r f re des situations de risque ou des proc dures dangereuses qui pourraient tre cause de dommages au produit ou aux appareils qui lui sont raccord s Attention Se r f re des situations de risque ou des proc dures dangereuses qui pourraient tre cause de dommages au produit ou de l sions la personne Symbole avec point d exclamation Le symbole signale des situations de risque ou des proc dures dangereuses qui pourraient tre cause de graves l sions la personne ou de mort Symbole avec foudre Le symbole signale des situations de risque ou des proc dures dangereuses qui causent de graves l sions la personne ou la mort 2 D CLARATION DE CONFORMIT Tous les g n rateurs JB4 sont fournis avec une d claration d incorporation conform ment la l gislation europ enne comme celle qui figure dans les derni res pages de ce manuel Suivant la Directive Machines CE le constructeur du groupe lectrog ne a la responsabilit de s assurer que les num ros de s rie et d identification du g n rateur sont report s sur la couverture de ce manuel 2 1 D claration de Compatibilit
108. litare i circuiti di chiusura e o collocare targhette di avviso su ogni interruttore automatico solitamente usato per il collegamento con la rete o con altri generatori al fine di prevenirne la chiusura accidentale Usare esclusivamente parti originali per qualsiasi manutenzione o ripara zione Nel caso in cui tale prescrizione non sia rispettata la Sincro S r l declina ogni responsabilit ai fini della sicurezza e del buon funzionamento del generatore e Istruire l utilizzatore dell impianto per la gestione l uso e la manutenzione del generatore Tutto quello che non espressamente previsto in queste istruzioni non permesso In questo manuale vengono utilizzati alcuni simboli e convenzioni che hanno un significato preciso Questi vengono qui definiti in modo univoco Importante Si riferisce a situazioni di rischio o a procedure pericolose che potrebbero essere causa di danni al prodotto o alle apparecchiature connesse Importante Si riferisce a situazioni di rischio o a pro cedure pericolose che potrebbero essere causa di danni al prodotto o alle apparec chiature connesse JB4 Dicembre 2003 Rev 01 3 ITALIANO Attenzione Si riferisce a situazioni di rischio o a pro cedure pericolose che potrebbero essere A AVVERTENZA PERICOLO causa di danni al prodotto o di lesioni alla persona Il simbolo segnala situazioni di rischio o procedure pericolose che POTREBBERO esse
109. lo statore eccitatrice regolando indirettamente tramite la catena rotore eccitatrice ponte diodi rotore principale il campo generato dal rotore principale Il controllo di tensione regola il valore medio della tensione di una fase mantenendolo costante Un dispositivo di controllo della frequenza interviene diseccitando progres sivamente la macchina quando la velocit del motore di trascinamento scende al di sotto di una soglia prefissata e regolabile impedendo una sovraeccitazione ai bassi regimi di funzionamento e alleviando l effetto di presa del carico sul motore infine possibile modulare la prontezza di risposta del regolatore al fine di eliminare eventuali instabilit di tensione che si dovessero manifestare 4 1 Scheda AVR Il regolatore di tensione della serie JB4 presenta una precisione di tensione Targa identificativa Targa dati elettrici Attenzione sulla targhetta compare la scritta I dati nominali sono riferiti al collegamento stella serie e il col legamento effettivamente realizzato dovr essere chiaramente contrassegnato a cura dell installatore fra quelli presenti nella lista onde evitare possibili malfunzionamenti ed eventualmente danni a per sone o cose Per la predisposizione di circuiti elettrici diversi da quello stella serie consultare la sezione e gli schemi specifici riportati nel seguito del manuale Scheda AVR JB4 Dicembre 2003 Rev 01 5
110. lument interdit e d en faire une utilisation impropre e d enlever les protections et de d connecter les dispositifs de protection Avertissement La carence d inspections et d entretien peut causer de graves dommages aux personnes et ou aux choses Du fait des pr cisions donn es plus haut toutes les op rations de caract re lectrique ou m canique doivent tre effectu es par du personnel qualifi 7 ASSISTANCE ET MAINTENANCE Avertissement Les proc dures de maintenance et de localisation des pannes comportent des risques qui pourraient causer de graves l sions personnelles ou la mort Ces proc dures doivent donc tre effectu es exclusivement par du personnel qualifi pour effectuer la maintenance lectrique et m canique S assurer avant toute op ration d entretien ou de nettoyage qu il n y a pas de parties sous tension que la carcasse du g n rateur est temp rature ambiante que le groupe lectrog ne ne peut pas tre mis en marche accidentellement et que toutes les proc dures sont effectu es correctement 7 1 Contr le des enroulements et de l tat d isolement L tat des enroulements est v rifiable en en mesurant la r sistance lectrique vers la masse Au cours de l essai le r gulateur de tension devra tre d connect En g n ral il suffit de contr ler uniquement l enroulement principal Les valeurs mesur es doivent tre sup rieures 2MOhm Si la r sistance d isolement est in
111. n Teilen f hrt zum Verfall der Garantie der Firma Sincro und zur Aufhebung der Haftung in Bezug auf die Konformit t mit den Normen und die entsprechenden Konsequenzen Die Installierung die technische Assistenz und die Wartung m ssen von entsprechend geschultem und ber die Vorschriften der EG Richtlinien informierten Personal ausgef hrt werden 3 EINF HRUNG Es wird dringend empfohlen den Generator bei Auslieferung sorgf ltig zu untersuchen um zu berpr fen dass er w hrend des Transports keine Sch den erlitten hat oder dass keine Teile fehlen 3 1 Kontrolle des Typenschilds Die Generatoren der Produktreihe JB4 sind durch ein Typenschild gekennzeichnet Dieses muss bei Auslieferung kontrolliert und mit den Spezifikationen des Auftrags verglichen werden um eventuelle Versand oder Konfigurationsfehler festzustellen 3 2 Positionierung des Schilds mit den elektrischen Spezifikationen der Seriennummer und dem Produktionsauftrag Es wird ein Klebeschild geliefert auf dem die f r jede Maschine unterschiedliche Seriennummer SN und der Produktionsauftrag PO aufgedruckt sind Das Schild muss vom Installateur in der in der Abbildung gezeigten Position angebracht werden damit es leicht lesbar ist Die Seriennummer und der Produktionsauftrag sind n mlich Daten die einen festen Bestandteil der bei der Beantragung von Kundendienstleistungen einzuleitenden Verfahrensabl ufe bilden Der Generator wird serienm ig mit einem we
112. ne del cuscinetto 7 4 3 Sostituzione dei diodi rotanti 7 4 4 Riassemblaggio di componenti e gruppi di componenti 8 PULIZIA E LUBRIFICAZIONE 9 DEMOLIZIONE E SMALTIMENTO 10 RICAMBI ED ASSISTENZA 10 1 Procedura e indirizzi di riferimento per richieste di assistenza 11 GARANZIA 2 JB4 Dicembre 2003 Rev 01 ITALIANO 1 NORME DI SICUREZZA Nel ringraziarVi per la preferenza accordata a questo prodotto la Sincro S r l certa che da esso otterrete le prestazioni necessarie al Vostro uso Il Manuale Uso e Manutenzione accluso al generatore fornisce importanti indicazioni riguardanti la sicurezza l installazione l uso e la manutenzione Questo prodotto risponde alle norme riconosciute della buona tecnica e delle disposizioni relative alla sicurezza Per le comunicazioni con la Sincro Srl si prega di citare sempre il tipo ed il codice del generatore rilevabili dall etichetta presente nell imballo Nel caso inoltre in cui vi siano malfunzionamenti o altri tipi di guasto nella macchina e si rendesse necessario interpellare il nostro Servizio Assistenza si prega di menzionare anche il numero di serie SN e l ordine di produzione PO ATTENZIONE Una installazione errata o un uso improprio del pro dotto pu creare danni a persone o cose Attenersi scrupolosamente a quanto riportato nel Manuale Uso e Manu tenzione che ha lo scopo di indicare le corrette condizioni di installazione impiego e man
113. ne del generatore possono comportare il dan neggiamento e o il malfunzionamento degli avvolgimenti Il gruppo rotore del generatore viene bilanciato dinamicamente in fabbrica con chiavetta intera versione bicuscinetto Le vibrazioni indotte dal motore sono complesse ed includono armoniche di ordine superiore che possono determinare combinandosi con quelle del generatore livelli di vibrazione sensibili e dannosi per il funzionamento del gruppo elettrogeno Pertanto compito del progettista utilizzare gli accorgi menti necessari per curare l allineamento e irriggidire basamento e supporti al fine di evitare il superamento dei limiti di vibrazione previsti dalle norme generatori bicuscinetto richiedono un telaio rigido per il sostegno del mo tore generatore in modo da costituire una buona base per un esatto alli neamento Tale telaio dovr essere vincolato al basamento mediante tamponi antivibranti AI fine di ridurre al minimo le oscillazioni torsionali si consiglia di utilizzare un giunto flessibile correttamente dimensionato Nei sistemi di trasmissione a cinghia applicati a generatori bicuscinetto necessario che il diametro e la struttura delle pulegge siano tali da consentire che il carico applicato all albero sia centrato rispetto alla lunghezza della sporgenza e non superi 4000N Per lunghezze d albero maggiori i valori di carico ammissibili potranno essere richiesti direttamente all Ufficio Tecnico Sincro L allineament
114. ne fornito con rotazione in senso orario guardando il lato accoppiamento a meno di specifiche diverse all atto dell ordine in modo da produrre una sequenza di fase U V W Se la rotazione deve essere in vertita successivamente alla consegna richiedere alla fabbrica gli opportuni schemi elettrici 6 4 3 Verifica di tensione e frequenza Controllare che i livelli di tensione e frequenza richiesti dal gruppo elettrogeno corrispondano a quelli riportati sulla targhetta del generatore Avvertenza Il generatore esce dalle linee di produzione con un colle gamento stella serie a meno di specifiche diverse all atto dell ordine rispetto al quale vengono forniti i dati nominali compito dell instal latore in caso di successiva modifica di tale collegamento contras segnare il nuovo collegamento usato sulla targhetta dei dati macchina presente all interno della scatola morsettiera Per effettuare il nuovo collegamento avvalersi degli schemi allegati al presente manuale Avvertenza Le eventuali modifiche al collegamento devono essere eseguite esclusivamente da personale qualificato 6 4 4 Regolazione scheda AVR Per scegliere le impostazioni del dispositivo di comando AVR accedere alla scheda di controllo dopo aver tolto le coperture La maggior parte delle regolazioni vengono effettuate in fabbrica su valori destinati ad assicurare risultati soddisfacenti nelle prove di funzionamento iniziali Potrebbero ren dersi necessarie delle ulter
115. nerador hay que examinarlo atentamente y verificar que no presente ning n da o ocasionado durante el transporte o que falte alguna pieza Atenci n Se refiere a situaciones de riesgo o ADVERTENCIA PELIGRO procedimientos peligrosos que podr an ocasionar da os al producto o lesiones a la persona Se ala situaciones de riesgo o procedi mientos peligrosos que podr an ocasionar graves lesiones a la persona o incluso la muerte Se ala situaciones de riesgo o procedi mientos peligrosos que ocasionan graves lesiones a la persona o incluso la muerte JB4 Dicembre 2003 Rev 01 59 ESPANOL Placa de caracteristicas a Placa datos el ctricos Atenci n En la placa consta la frase Los datos nomi nales se refieren a la conexi n estrella serie as que la conexi n realmente efectuada ser marcada por el instalador con claridad entre las indicadas en la lista a fin de evitar posi bles malfuncionamientos y eventualmente da os a las personas o a las cosas Para la preparaci n de circuitos el ctricos diferentes al estrella serie consultar el apartado y los esquemas espec ficos indicados m s adelante en el manual Tarjeta AVR 60 JB4 Dicembre 2003 Rev 01 3 1 Control de la placa de caracter sticas Todos los generadores de la gama JB4 llevan una placa de caracter sticas Al recibir los aparatos se controlar la citada placa y se com
116. ngebracht sie nach Typologie zu trennen elektrische Teile Kupfer Aluminium etc 10 ERSATZTEILE UND KUNDENDIENST 10 1 Verfahrensablauf und Adressen zur Bezugnahme bei Anforderung von Kundendienstleistungen Unser Kundendienst liefert eine vollst ndige technische Beratung Bei Beantragung von Kundendienstleistungen im Rahmen der Garantie sicherstellen dass alle Kenndaten des Generators seine Seriennummer und die Nummer des Produktionsauftrags die auf dem gem Absatz 3 2 der vorliegenden Bedienungsanleitung positionierten Klebeschild angegeben sind zur Verf gung stehen Die Liste der autorisierten Kundendienst Center finden Sie in unserem Internet Site www sogagroup com 11 GARANTIE Die Firma Sincro s r l garantiert die Qualit t Sicherheit und Zuverl ssigkeit aller ihrer Produkte Die Laufzeit der Garantie gegen Defekte oder Funktionsst rungen die sich aus Konstruktions oder Materialfehlern ergeben betr gt 12 Monate ab dem Lieferdatum Die Garantiefristen k nnen keinesfalls verl ngert werden auch dann nicht wenn der Drehstromgenerator in der Zwischenzeit nicht in Betrieb genommen wurde Falls sich w hrend des Garantiezeitraums Bearbeitungs oder Materialmo ntagefehler bemerkbar machen sollten nimmt die Firma Sincro s r l auf eigene Kosten in k rzestm glicher Zeit die Reparatur oder Auswechselung der schadhaften Teile vor Die Meldung des Defekts muss innerhalb von 8 Tagen nach Feststellung erfolgen ansonsten v
117. ning Inadequate protection and or bad alignment of the generator can cause injury to persons and or damage to equipment 6 3 Earthing The generator housing has to be soundly connected to earth on the base of the electricity generating set If flexible antivibration supports are mounted WARNING Caution Caution The generator is supplied without a con nection to earth to make this connection refer to relevant local regulations An inef ficient earth connection or safety cut out can cause injury or death An error in installation use maintenance or replacement of parts can cause severe injury or death not to mention damage to the machinery All work on electrical and or mechanical parts must be carried out by a qualified specialist An insufficient loadbearing capacity can cause severe injury and damage The lifting lugs on the generator have been designed for lifting only the generator and not the whole electricity generating set Before proceeding with assembly check that the couplings both on generator and motor are in order and perfectly clean A WARNING Inadequate protection and or bad align ment of the generator can cause injury to persons and or damage to equipment JB4 Dicembre 2003 Rev 01 21 ENGLISH
118. no il cuscinetto a solle citazioni che ne riducono la vita JB4 Dicembre 2003 Rev 01 11 ITALIANO 12 JB4 Dicembre 2003 Rev 01 7 3 Anomalie e rimedi Il generatore non si eccita e Controllare il fusibile e Aumentare la velocit del 15 e Applicare per un istante ai poli del regolatore elettronico una tensione di 12V di una batteria con in serie una resistenza di 300hm rispettando le polarit Dopo eccitato si diseccita Controllare i cavi di collegamento servendosi dei disegni allegati A vuoto tensione bassa e Ritarare la tensione Controllare il numero di giri Controllare gli avvolgimenti A vuoto tensione troppo alta Ritarare la tensione e Sostituire il regolatore A carico tensione inferiore alla nominale Ritarare la tensione e Corrente troppo alta coso inferiore a 0 8 velocit inferiore del 4 della nominale e Sostituire il regolatore e Controllare i diodi scollegando i cavi A carico tensione superiore alla nominale Ritarare la tensione Sostituire il regolatore Tensione instabile e Controllare uniformit di rotazione e Regolare la stabilit del regolatore agendo sul potenziometro ST Per qualsiasi altra anomalia rivolgersi al centro di Assistenza Sincro 7 4 Rimozione e sostituzione di componenti e gruppi di componenti 7 4 1 Estrazione ed inserimento dell albero Le procedure che seguiranno presuppongono che l alterna
119. ns other than the factory star series connection standard unless otherwise specified on order 6 4 6 Initial start up Before starting up the electricity generating set check that all external con nections are in order and that the protections are in place The various generator parameters are factory set before testing so no further adjustments on the machine should be necessary in the event that the cov ers need to be removed for the adjustments and live electrical contacts are left bare it is important that this operation be carried out solely by qualified specialists in electrical plant maintenance During the initial start up pay particular attention for any unusual noises that might signal an incorrect alignment between motor and generator Warning Do not touch the generator while in operation and straight after the generating set has stopped since certain parts may still be very hot Generators are rotating electrical machines that involve potentially hazardous live or moving parts therefore the following is strictly prohibited an improper use removal of covers and disconnection of safeties Warning The lack of routine check ups and poor maintenance can cause severe damage to persons and or objects Due to these inherent hazards all work of an electrical or mechanical nature must be carried out by qualified specialists Trimmer V Trimmer ST Caution WARNING EXT POT 115
120. nte eseguito in produzione a meno di specifiche diverse all atto dell ordine 6 4 6 Messa in marcia Prima dell avviamento del gruppo elettrogeno necessario verificare che tutti i collegamenti esterni siano stati eseguiti correttamente e che le protezioni non siano state rimosse Le varie regolazioni del generatore sono eseguite in fabbrica al momento del collaudo non dovrebbero quindi essere necessarie ulteriori azioni di regolazione della macchina nel caso in cui si rendesse necessario rimuo vere delle coperture allo scopo di eseguire delle regolazioni e si lascias sero scoperti dei contatti sotto tensione si raccomanda che tali operazioni vengano eseguite solamente da personale qualificato nella manutenzione di impianti elettrici All atto della messa in funzione porre attenzione ad eventuali rumori ano mali che potrebbero indicare un allineamento non corretto tra motore e generatore Avvertenza Non toccare il generatore durante il funzionamento e subito dopo l arresto del gruppo in quanto potrebbero esservi delle superfici a temperatura elevata generatori sono macchine elettriche rotanti che presentano parti poten zialmente pericolose in quanto poste sotto tensione o dotate di movimento durante il funzionamento pertanto assolutamente vietato ITALIANO un uso improprio la rimozione delle protezioni e lo scollegamento dei dispositivi di prote zione Avvertenza La carenza di ispezioni e manu
121. o dei generatori monocuscinetto critico perch potrebbero prodursi vibrazioni in corrispondenza dell accoppiamento fra motore e ge neratore A tal fine necessario curare l assemblaggio dell alternatore al motore prevedere un basamento solido e l impiego di tamponi antivibranti per supportare l assieme motore alternatore All interno della scatola morsettiera si trovano i terminali isolati per le con nessioni di linea e di neutro e per il collegamento a massa Il neutro NON collegato alla carcassa Avvertenza Il generatore viene fornito senza alcun collegamento a massa per il collegamento si dovr fare riferimento alle corrispondenti disposizioni locali Collegamenti a massa o di protezione eseguiti in modo errato possono essere causa di lesioni o di decesso valori delle correnti di guasto del generatore sono disponibili su richiesta al fine di aiutare il progettista nel dimensionamento dell impianto e dei suoi componenti Avvertenza Una installazione uso manutenzione o sostituzione di parti eseguite in modo errato possono essere causa di gravi lesioni personali o di decesso nonch di danneggiamento delle attrezzature Gli interventi sulle parti elettriche e meccaniche devono essere ese guiti da personale qualificato 6 INSTALLAZIONE 6 1 Sollevamento Sollevare e movimentare il generatore con mezzi idonei supportandoli con pallet o sostenendoli mediante gli anelli di sollevamento presenti sul gene r
122. onnections ENGLISH Caution The plate shows the phrase Nominal data refers to a star series connection and the connection effectively made should be clearly marked by the installer on the connections list in order to avoid malfunctions and even damage to persons or objects Caution For electrical circuits other than star series consult the sec tion and specific wiring diagrams given in this manual The Sincro Technical Office is always available for any clarification The data plate is supplied loose so that it can be applied to the generator in the position indicated in the figure after any coating is completed The surface receiving the plate must be smooth clean and any coating should be completely dry To make sure its is firmly applied remove about 20mm of backing paper When this piece is in position and firmly applied the backing paper can be gradually pulled away while the plate is being pressed in position A full bond is obtained after 24 hours 4 OPERATING PRINCIPLE AND CHARACTERISTICS OF THE VOLTAGE REGULATOR SYSTEM The exciter stator has a residual magnetism which guarantees self exciting of the generator on start up that thereby generates a residual voltage of about 10 nominal voltage The AVR powered by an auxiliary circuit on the main stator acts on the exciter stator indirectly controlling the field generated by the main rotor by means of the sequence exciter rotor diode bridge main roto
123. or el motor o por una alineaci n err nea de los componentes del grupo electr geno someten el cojinete a esfuerzos que reducen su vida 7 3 Anomal as y remedios El generador no se excita e Controlar el fusible e Aumentar la velocidad del 15 Aplicar por un instante a los polos del regulador electr nico una tensi n de 12V de una bater a con una resistencia en serie de 300hm respetando las polaridades Despu s de haberlo excitado se desexcita Controlar los cables de conexi n usando los dibujos adjuntos En vac o tensi n baja Recalibrar la tensi n e Controlar el n mero de revoluciones Controlar los devanados En vac o tensi n demasiado alta Recalibrar la tensi n Sustituir el regulador Con carga tensi n inferior a la nominal e Recalibrar la tensi n e Corriente demasiado alta cos inferior a 0 8 velocidad inferior a la norminal de un 4 Sustituir el regulador e Controlar los diodos desconectando los cables En carga tensi n superior a la nominal e Recalibrar la tensi n Sustituir el regulador Tensi n inestable Controlar la uniformidad de rotaci n e Regular la estabilidad del regulador mediante el potenci metro ST Para cualquier otra anomal a acudir al centro de Asistencia Sincro 7 4 Desmontaje y sustituci n de componentes y grupos de componentes 7 4 1 Extracci n e inserci n del eje Las siguientes intervenciones ser n llevad
124. orme SAE 6 2 2 D montage forme SAE 6 3 Mise la terre 6 4 Contr les pr liminaires 6 4 1 Contr le de l isolement 6 4 2 Sens de rotation 6 4 3 V rification de tension et de fr quence 6 4 4 R glage carte AVR 6 4 5 Sch mas de connexion pour diff rents circuits 6 4 6 Mise en service 7 ASSISTANCE ET MAINTENANCE 7 1 Contr le des enroulements et de l tat d isolement 7 2 Contr le des roulements 7 3 Anomalies et rem des 7 4 Enl vement et remplacement de composants et groupes de composants 7 4 1 Extraction et mise en place de l arbre 7 4 2 Remplacement du roulement 7 4 3 Remplacement des diodes rotatives 7 4 4 R assemblage de composants et de groupes de composants 8 NETTOYAGE ET LUBRIFICATION 9 D MOLITION ET MISE AU REBUT 10 PI CES DE RECHANGE ET SERVICE APR S VENTE 10 1 Proc dure et adresses de r f rence pour demandes de service apr s vente 11 GARANTIE JB4 Dicembre 2003 Rev 01 43 FRAN AIS 44 JB4 Dicembre 2003 Rev 01 1 NORMES DE S CURIT Tout en vous remerciant de la pr f rence que vous avez accord e ce produit Sincro S r l est s re qu il vous permettra d obtenir les performances n cessaires votre application Le Manuel d Instructions et de Maintenance joint au g n rateur fournit des indications importantes concernant la s curit l installation l utilisation et la maintenance Ce produit r pond aux normes reconnues de la bonne technique et au
125. otor siguiendo las instrucciones del apartado 7 4 1 pero en secuencia inversa Como alternativa es posible sustituir el cojinete sin extraer el rotor Desatornillar los 4 tornillos que fijan el escudo posterior a la caja e Golpear homog neamente el escudo hasta que se separe completamente el rotor e Quitar la arandela el stica tipo seeger e Quitar el cojinete mediante extractores comunes e Coger el nuevo cojinete y calentarlo con un calentador para que se dilate el di metro antes de insertarlo en el alojameinto del eje Volver a montar la arandela seeger Insertar el escudo sin olvidar montar la arandela el stica e insertar parcialmente los tornillos de fijaci n e Golpear homog neamente el escudo hasta que se inserte completamente el cojinete y la porci n de caja en sus respectivos alojamientos e Apretar bien los tornillos de fijaci n del escudo 7 4 3 Sustituci n de los diodos rotatorios Extraer el rotor siguiendo las instrucciones del apartado 7 4 1 Desconectar el puente de diodos Desatornillar los tornillos y quitar el puente de diodos Montar el nuevo puente de diodos fijando los tornillos con cola para fijar tornillos y conectar los conectores Reinsertar el rotor siguiendo las instrucciones del apartado 7 4 1 pero en secuencia inversa Como alternativa es posible sustituir el puente de diodos desmontando s lo el escudo posterior como descrito anteriormente para la sustituci n
126. ous procedures that could cause damage to the product or connected equipment Caution This refers to risk conditions or hazardous procedures that could cause damage to the product or injury to persons Exclamation mark symbol This symbol signals risk conditions or haz ardous procedures that COULD cause severe injury or death Lightning symbol This symbol signals risk conditions or hazardous procedures that will cause severe injury or death Important This refers to risk conditions or to hazar dous procedures that could cause damage to the product or connected equipment Caution This refers to risk conditions or hazardous procedures that could cause damage to the product or injury to persons This symbol signals risk conditions or hazardous procedures that COULD cause severe injury or death WARNING This symbol signals risk conditions or hazardous procedures that will cause severe injury or death DANGER JB4 Dicembre 2003 Rev 01 17 ENGLISH ID plate 18 JB4 Dicembre 2003 Rev 01 Electrical specifications plate 2 CONFORMITY DECLARATION All JB4 generators are supplied with a declaration of incorporation in ac cordance with European rules and regulations as provided in final pages of this manual According to the EC Machine Directive it is the electricity generating set con structor s responsibility to ensure that the generator serial and identification number
127. parar n sus datos con las especificaciones del pedido con el fin de comprobar los posibles errores de env o o de configuraci n 3 2 Posicionamiento de la placa con las especificaciones el ctricas el n mero de serie y de la orden de producci n Se entrega una placa adhesiva en la que est n impresos el n mero de serie SN distinto para cada m quina y la orden de producci n PO El instalador colocar dicha placa en la posici n indicada en la figura de modo que sea f cilmente legible de hecho tanto el n mero de serie como el de la orden de producci n son datos integrantes de los procedimientos a utilizar al requerirse la intervenci n de la asistencia El generador se suministra junto a otra placa adhesiva en la que aparecen los datos las especificaciones el ctricas y la lista de las posibles conexiones Atenci n En la placa consta la frase Los datos nominales se refieren a la conexi n estrella serie as que la conexi n realmente efectuada ser marcada por el instalador con claridad entre las indicadas en la lista a fin de evitar posibles malfuncionamientos y eventualmente da os a las personas o a las cosas Atenci n Para la preparaci n de circuitos el ctricos diferentes al estrella serie consultar el apartado y los esquemas espec ficos indicados m s adelante en el manual El Departamento T cnico Sincro est a su completa disposici n para cualquier aclaraci n La placa de caracter st
128. r The voltage regulator controls and keeps constant the average voltage of one phase A frequency control progressively deactivates the machine when the drive motor speed drops below a pre set adjustable threshold preventing over excitement at low operating speeds and abating the load engage effects on the motor In conclusion the regulator reaction time can be modulated to eliminate any voltage instability that may arise 4 1 AVR board The voltage regulator in the JB4 series has a 2 voltage precision in the machine working range with distortion free loads The output voltage can be adjusted by trimmer V see figure from 185 to 290V with a 10 tolerance An additional jumper can take the range from 220 to 320V with the same 10 tolerance The regulator is equipped with a frequency dependant excitation limiter the frequency can be calibrated by trimmer UF which is factory set at 46Hz 1Hz On reaching this frequency the machine begins to reduce its voltage until it deactivates for very low frequencies Afuse protects the regulator and generator against overloads and or faults a pocket has been provided on the edge of the board to hold a spare fuse rapid type 32x6 3 2 5A Another trimmer ST allows to adapt the regulator to the generator pa rameters The regulator has been built to suppress the voltage surges on releasing the load that are below 20 at nominal load 5 GENERAL MECHANICAL AND ELECTRICAL SPECIFICATIONS FOR
129. r 6 und die auf der Glocke angebrachten Plastikdeckel 7 entfernen Kontrollieren dass der Durchmesser der Scheibe 3 dem Aufnahmedurchmesser im Schwungrad 2 entspricht Den Generator durch Blockierung der Glocke SAE 1 am Motor befestigen wobei die bereinstimmung der Bohrungen der Scheibe mit denen des Schwungrads kontrolliert wird berpr fen dass die Scheibe auf dem Schwungrad aufliegt indem man axial mit einem Plastikhammer und einem Puffer auf den Rotor klopft DEUTSCH Die Scheibe am Schwungrad befestigen Uberpr fen dass der Rotor und der Stator des Erregers untereinander perfekt gefluchtet sind e Das Aggregat mit Vibrationsd mpfern 5 st tzen und dabei auf die korrekte Ausnivellierung zwischen Motor und Generator achten Die Gitter und die Deckel wieder montieren 6 2 2 Demontage Form SAE Zur Demontage die unter Absatz 6 2 1 gegebenen Anleitungen umgekehrt ausf hren Warnhinweis Ein ungeeigneter Schutz und oder eine falsche Fluchtung des Generators k nnen zu Verletzungen von Personen und oder Sch den an der Ausr stung f hren 6 3 Erdung Das Geh use des Generators muss einen soliden Erdungsanschluss am Untergestell des Elektro Aggregats aufweisen Falls flexible vibrationsd mpfende St tzen zwischen dem Geh use des Generators und seinem Untergestell vorgesehen sind muss ber die flexible St tze ein Erdungsleiter mit einem geeigneten Nennwert gew hnlich die H lfte
130. r favor el n mero de serie SN y el de la orden de producci n PO ATENCI N Sea una instalaci n no correcta sea el uso impropio del producto pueden ocasionar da os a las personas o a las cosas Cumplir rigurosamente las indicaciones del Manual de uso mantenimiento pues su finalidad es indicar las condiciones correctas de instalaci n as como de uso y mantenimiento a fin de prevenir posibles malfuncionamientos del generador y evitar situaciones de peligro para el usuario e Eliminar los materiales de embalaje pl stico cart n poliestireno etc en conformidad con las disposiciones de las normas vigentes e Conservar las instrucciones para adjuntarlas a la gu a t cnica y para futuras consultaciones e Este producto ha sido dise ado y fabricado exclusivamente para el empleo indicado en esta documentaci n Las destinaciones no indicadas en este manual podr an ocasionar da os al producto y ser fuente de peligro e Sincro S r l declina toda responsabilidad por el uso impropio o distinto al que est destinado la m quina y que consta en esta documentaci n instalar el producto en atm sfera potencialmente explosiva Los elementos constructivos de la instalaci n cumplir n las Directivas Europeas Respecto de los pa ses extra CEE adem s de las normas nacionales en vigor ser conveniente cumplir asimismo las normas citadas anteriormente con el fin de obtener un buen nivel de seguridad e La ins
131. ra s assurer que la temp rature de l air de refroidissement envoy e au g n rateur ne d passe pas la temp rature nominale pr vue Le capot doit tre r alis de mani re que la prise dar du moteur dans le capot soit s par e de celle du g n rateur surtout si l aspiration sous le capot doit tre assur e par le ventilateur de refroidissement La prise d air du g n rateur en outre devra tre r alis e de mani re emp cher les infiltrations d humidit en pr voyant un filtre ad quat Le capot devra tre projet de mani re laisser entre la prise d air du g n rateur et toute surface plane une distance d au moins 50mm Si cela est pr cis au moment de la commande le g n rateur peut tre fourni avec filtres air Important Une r duction du flux de l air de refroidissement ou une protection inad quate du g n rateur peuvent entra ner endommagement et ou le mauvais fonctionnement des enroulements Le groupe rotor du g n rateur est quilibr dynamiquement l usine avec une clavette enti re version double roulement Les vibrations induites par le moteur sont complexes et incluent des harmoniques d ordre sup rieur qui peuvent d terminer en se combinant avec celles du g n rateur des niveaux de vibration sensibles et nuisibles pour le fonctionnement du groupe lectrog ne LU auteur du projet est donc tenu de prendre les pr cautions n cessaires pour assurer l alignement et la rigid
132. rario si se regula con un valor demasiado alto puede ocasionar ca das de tensi n con cargas elevadas Conexi n de un potenci metro exterior 5kOhm quitar el puente en los bornes EXT POT y conectar en los cabos libres el potenci metro teniendo cuidado de posicionarlo en el valor de m xima resistencia Girar el trimmer V en sentido contrario a las agujas del reloj hasta la posici n extrema Llevar al grupo a la velocidad nominal y utilizar el potenci metro hasta alcanzar la tensi n deseada De verificarse fluctuaciones de la tensi n de carga se puede accionar el potenci metro ST que modula la rapidez de respuesta del regulador con est mulos exteriores permitiendo eliminar posibles inestabilidades del sistema alternador carga 6 4 5 Esquemas de conexi n para distintos circuitos Se adjuntan al presente manual los esquemas de distintas conexiones de la conexi n estrella serie normalmente realizada en la producci n de no especificarse diversamente en el pedido 6 4 6 Puesta en marcha Antes de poner en marcha el grupo electr geno es necesario verificar que todas las conexiones exteriores hayan sido realizadas correctamente y que las protecciones no est n desmontadas En la f brica se han llevado a cabo las distintas regulaciones del generador durante la prueba de idoneidad Por tanto la m quina no deber a requerir otros ajustes De tener que desmontar el recubrimiento a fin de realizar otras regulaciones de
133. rata in un gruppo elettrogeno non possibile applicare in fase di costruzione tutte le neces sarie etichette di segnalazione sul generatore Queste etichette che indicano pericolo potenziale e rischio per presenza di componenti in tensione vengono fornite sciolte e devono essere applicate a cura del costruttore del gruppo elettrogeno nelle posizioni indicate nella figura a lato una volta completato l assemblaggio del gruppo generatori della gamma JB4 sono progettati per il funzionamento ad una temperatura massima di 40 C e ad una quota massima di 1000m s l m Entro tali limiti di temperatura e quota essi forniscono le prestazioni nominali indicate sulla targa Per temperature superiori a 40 C e o quote superiori a 1000m s l m si manifestano riduzioni di prestazioni vedi tabella opportuno che il funzionamento in condizioni ambientali peggiori di quelle precedentemente nominate sia segnalato all Ufficio Tecnico Sincro generatori sono dotati di sistema di ventilazione ad aria di schermi di protezione e carcasse antigocciolamento non sono adatti per l installazione all aperto salvo che siano protetti da adeguate coperture Durante la perma nenza a magazzino prima dell installazione ovvero come riserva si consiglia l uso di scaldiglie anticondensa per garantire la buona conservazione degli avvolgimenti Prima della messa in servizio o dopo lunghi periodi di inattivit si deve controllare la resistenza d isolamento verso massa d
134. rauch die Wartung oder die Auswechselung von Teilen k nnen bei falscher Ausf hrung zu schweren Verletzungen von Personen oder zum Tod sowie auch zu Besch digung der Ausr stungen f hren Die Eingriffe an elektrischen und oder mechanischen Teilen m ssen von Fachpersonal ausgef hrt werden 6 INSTALLIERUNG 6 1 Heben Den Generator mit geeigneten Mitteln heben und bewegen unter Zuhilfenahme von Paletten oder mit Abst tzung ber die Heberinge die am Generator in den in der Abbildung angegebenen Positionen vorhanden sind Zum Heben des Generators Vorrichtungen benutzen die eine Hebekapazit t von mindestens 400kg aufweisen Achtung Eine nicht geeignete Hebekapazit t kann zu Verletzungen von Personen und schweren Sch den f hren Achtung Die am Generator vorhandenen Heberinge wurden nur zum Heben des Generators und nicht des gesamten Elektro Aggregats vorgesehen Beim Heben und bei der Bewegung von Einlager Generatoren muss die Maschine in horizontaler Position gehalten werden um zu verhindern dass der Rotor falls der Arbeitsvorgang nicht korrekt ausgef hrt wird heraustritt was zu dessen Besch digung und schweren Folgen f r die Personen f hren kann 6 2 Befestigung am Motor 6 2 1 Montage Form SAE siehe Abbildung Achtung Vor der Montage berpr fen dass die Kupplungssitze sowohl des Generators als auch des Motors einwandfrei und sauber sind Die Befestigungsstange des Rotors entfernen Die Schutzgitte
135. rd um seiner unbeabsichtigten Schlie ung vorzubeugen Bei allen Wartungs oder Reparaturarbeiten ausschlie lich Original Ersatzteile verwenden Falls diese Vorschrift nicht eingehalten wird lehnt die Firma Sincro S r l jegliche Verantwortung hinsichtlich der Sicherheit und einwandfreien Funktion des Generators ab Den Benutzer der Anlage in die Steuerung den Gebrauch und die Wartung des Generators einweisen Alles was in dieser Anleitung nicht ausdr cklich vorgesehen ist ist nicht erlaubt JB4 Dicembre 2003 Rev 01 29 DEUTSCH Wichtig Achtung HINWEIS GEFAHR Bezieht sich auf Risiko Situationen oder gef hrliche Verfahrensabl ufe die Sch den am Produkt oder an den angeschlossenen Apparaten verursachen k nnten Bezieht sich auf Risiko Situationen oder gef hrliche Verfahrensabl ufe die Sch den am Produkt oder Verletzungen der Person verursachen k nnten Bezieht sich auf Risiko Situationen oder gef hrliche Verfahrensabl ufe die schwere Verletzungen der Person oder deren Tod verursachen K NNTEN Das Symbol weist auf Risiko Situationen oder gef hrliche Verfahrensabl ufe hin die schwere Verletzungen der Person oder deren Tod verursachen 30 JB4 Dicembre 2003 Rev Ol In diesem Handbuch werden einige Symbole und konventionelle Zeichen benutzt die eine pr zise Bedeutung haben Diese werden hier auf eindeutige Weise definiert Wichtig Bezieht sich auf R
136. rdere il magnetismo residuo che permette l autoeccitazione Prima dell av viamento del gruppo risulta quindi necessario rieccitare l alternatore applicando ai morsetti dell eccitatrice una tensione di 6 12 volt per un secondo rispettando la polarit 7 4 2 Sostituzione del cuscinetto Far riferimento al paragrafo 7 4 1 e Togliere l anello elastico tipo seeger e Togliere il o i cuscinetti tramite estrattori comuni Prendere il o i nuovi cuscinetti e mediante un riscaldatore riscaldarli in modo da dilatare il diametro prima di inserirlo nella sede dell albero e Rimontare l anello seeger Reinserire il rotore seguendo a ritroso le istruzioni fornite al paragrafo 7 4 1 Alternativamente possibile sostituire il cuscinetto senza estrarre il rotore Svitare le 4 viti che fissano lo scudo posteriore alla cassa e Colpire in maniera omogenea lo scudo fino al completo distacco dal rotore e Togliere l anello elastico tipo seeger Togliere il cuscinetto tramite estrattori comuni Prendere il nuovo cuscinetto e mediante un riscaldatore riscaldarlo in modo da dilatare il diametro prima di inserirlo nella sede dell albero e Rimontare l anello seeger e Posizionare lo scudo senza scordarsi l anello elastico e inserire parzial mente le viti di fissaggio e Colpire in maniera omogenea lo scudo fino al completo inserimento del cuscinetto e della porzione di cassa nelle rispettive sedi e Serrare le viti di fiss
137. re causa di gravi lesioni alla persona o di decesso Il simbolo segnala situazioni di rischio o procedure pericolose che causano gravi lesioni alla persona o decesso 4 JB4 Dicembre 2003 Rev 01 Attenzione Si riferisce a situazioni di rischio o a procedure pericolose che potrebbero essere causa di danni al prodotto o di lesioni alla per sona Simbolo con punto esclamativo Il simbolo segnala situazioni di rischio o procedure pericolose che POTREBBERO essere causa di gravi lesioni alla persona o di decesso Simbolo con fulmine Il simbolo segnala situazioni di rischio o proce dure pericolose che causano gravi lesioni alla persona o decesso 2 DICHIARAZIONE DI CONFORMIT Tutti i generatori JB4 sono forniti con una dichiarazione di incorporamento in accordo con la legislazione europea come quella riportata sulle ultime pagine del presente manuale Secondo la Direttiva Macchine CE responsabilit del costruttore del gruppo elettrogeno assicurarsi che i numeri di serie e di identificazione del generatore siano riportati sulla copertina di questo manuale 2 1 Dichiarazione di Compatibilit elettromagnetica generatori JB4 sono costruiti con criteri e materiali che ne certificano la compatibilit con le seguenti Direttive europee CEE 73 23 CEE 89 336 98 37 CE e successive modifiche alle norme CEl 2 3 EN 60034 1 EN 55011 EN 50081 1 EN 50082 1 generatori tipo JB4 vengono inoltre forniti sulle seguenti basi
138. remplac s au bout de 15 000 heures de fonctionnement Important La dur e des roulements est fortement influenc e par les conditions et le milieu de travail Important De longs s jours dans un environnement caract ris par la pr sence de vibrations peuvent endommager les billes et les si ges de roulement La pr sence d une humidit trop lev e peut causer l mulsion de la graisse et favoriser la corrosion Important Des vibrations intenses caus es par le moteur ou par un alignement incorrect des composants du groupe lectrog ne soumettent le roulement des sollicitations qui en r duisent la dur e de vie 7 3 Anomalies et rem des Le g n rateur ne s excite pas e Contr ler le fusible Augmenter la vitesse de 15 e Appliquer pendant un instant aux p les du r gulateur lectronique une tension de 12V d une batterie avec en s rie une r sistance de 300hm en respectant la polarit Apr s s tre excit il se d sexcite e Contr ler les c bles de connexion en consultant les sch mas fournis vide tension basse e R gler de nouveau la tension Contr ler le nombre de tours e Contr ler les enroulements vide tension trop haute e R gler de nouveau la tension Remplacer le r gulateur Sous charge tension inf rieure la tension nominale e R gler de nouveau la tension e Courant trop lev cosy inf rieur 0 8 vitesse inf rieure de 4 par rapport la vitess
139. rico sobre el motor Por ltimo se puede modular la rapidez de respuesta del regulador con el prop sito de eliminar las posibles inestabilidades de tensi n que se manifestaran ESPANOL 4 1 Tarjeta AVR El regulador de tensi n de la serie JB4 presenta una precisi n de tensi n del 2 en el campo operativo de la m quina con cargas no distorsionales Se puede regular la tensi n de salida con el trimmer V ver figura de 185 a 290V con una tolerancia del 10 Tr mite un puente adicional se consigue un campo de variaci n de 220 a 320V siempre con una tolerancia del 10 El regulador est provisto de protecci n de limitaci n de excitaci n en funci n de la frecuencia la frecuencia se calibra con el trimmer UF y el precalibrado se da a 46Hz 1Hz Al alcanzar dicha frecuencia la m quina empieza a reducir su propia tensi n hasta desexcitarse por frecuencias muy bajas Un fusible protege tanto el regulador como el generador contra sobrecargas y o aver as un bolsillo realizado en el borde de la tarjeta contiene un fusible de repuesto fusible tipo 32x6 3 2 5A r pido Otro trimmer ST permite adaptar el regulador a los par metros del generador El regulador se ha construido para contener al m nimo los picos de tensi n al desconectar la carga que resultan inferiores al 20 con carga nominal 5 ESPECIFICACIONES GENERALES MEC NICAS Y EL CTRICAS PARA EL ACOPLAMIENTO CON EL MOTOR Dado que se trata de una unidad s
140. risulta quindi necessario rieccitare l alternatore applicando ai morsetti dell eccita trice una tensione di 6 12 volt per un secondo rispettando la polarit Qualunque tipo di intervento di pulizia deve essere eseguito con gruppo elettrogeno fermo e gene ratore scollegato dalla rete elettrica pena grave pericolo per persone e cose JB4 Dicembre 2003 Rev 01 13 ITALIANO Non utilizzare in alcuna occasione liquidi o acqua Non pulire con aria compressa le parti elettriche interne perch potrebbero verificarsi cortocircuiti o altre anomalie AVVERTENZA Avvalersi esclusivamente di personale quali ficato 14 JB4 Dicembre 2003 Rev 01 Avvertenza Non utilizzare in alcuna occasione liquidi o acqua Non pulire con aria compressa le parti elettriche interne perch potrebbero verificarsi cortocircuiti o altre anomalie 9 DEMOLIZIONE E SMALTIMENTO Avvertenza Avvalersi esclusivamente di personale qualificato L eliminazione dei materiali va fatta nel rispetto delle norme vigenti Nel caso di demolizione del generatore non esistono particolari rischi o pericoli derivanti dal generatore stesso opportuno in caso di recupero materiali che vengano separati per tipologia parti elettriche rame alluminio plastica etc 10 RICAMBI ED ASSISTENZA 10 1 Procedura e indirizzi di riferimento per richieste di assistenza Il nostro Servizio di Assistenza fornisce completa consulenza tecnica As
141. rmative e le relative conseguenze Installazione assistenza e manutenzione devono essere eseguite da per sonale adeguatamente istruito ed a conoscenza dei dettami delle direttive CE 3 INTRODUZIONE Si raccomanda di esaminare attentamente il generatore al momento della consegna per verificare che non abbia subito danneggiamenti durante il trasporto o vi siano particolari mancanti ITALIANO 3 1 Controllo targa identificativa generatori della gamma JB4 sono contraddistinti da una targa identificativa Questa deve essere controllata e confrontata con le specifiche dell ordine al momento della consegna onde accertare eventuali errori di spedizione o di configurazione 3 2 Posizionamento della targa con le specifiche elettriche il numero di serie e l ordine di produzione Viene fornita una targhetta adesiva su cui sono stampati il numero di serie SN diverso per ogni macchina e l ordine di produzione PO La targhetta deve essere posizionata dall installatore nella posizione indicata in figura in modo che sia facilmente leggibile il numero di serie e Pordine di produzione infatti sono dati che fanno parte integrante delle procedure da attuarsi in corrispondenza alla richiesta di interventi d assistenza generatore viene fornito con a corredo una ulteriore targhetta adesiva su cui sono riportati i dati e le specifiche elettriche e la lista dei possibili collegamenti Attenzione Sulla targhetta compare la
142. rnen Potentiometers 5kOhm Die Br cke auf den Endverschl ssen EXT POT entfernen und an den freien Enden das Potentiometer anschlieRen wobei darauf geachtet werden muss es auf den h chsten Widerstandswert zu positionieren Den Trimmer V bis zum Anschlag gegen den Uhrzeigersinn drehen Das Aggregat auf Nenndrehzahl fahren und auf das Potentiometer einwirken bis die gew nschte Spannung erreicht ist Falls Spannungsfluktuationen bei Last auftreten sollten kann auf das Potentiometer ST eingewirkt werden das die Reaktionsbereitschaft des Reglers auf externe Reize moduliert wodurch die Eliminierung eventueller Instabilit ten des Systems Drehstromgenerator Last m glich wird 6 4 5 Anschluss Schaltpl ne f r verschiedene Kreise Der vorliegenden Bedienungsanleitung sind die Schaltpl ne f r Anschl sse die von der Stern Serienschaltung die normalerweise w hrend der Produktion ausgef hrt wird sofern bei Auftragserteilung nicht anderweitig spezifiziert abweichen beigef gt 6 4 6 Inbetriebnahme Vor dem Start des Elektro Aggregats muss berpr ft werden dass alle externen Anschl sse korrekt ausgef hrt wurden und dass die Schutzabdeckungen nicht entfernt wurden Die verschiedenen Einstellungen des Generators werden bei der Abnahme im Werk ausgef hrt Es d rften also keine weiteren Einstellarbeiten an der Maschine erforderlich sein Falls es sich doch als n tig erweisen sollte zur Ausf hrung von Einstellun
143. rtains accessoires suppl mentaires pourraient se rendre n cessaires e Le sch ma d installation demande la mise la terre de la carcasse du g n rateur en utilisant un c ble de section ad quate et le plus court possible e L utilisation de pi ces de rechange non originales ou qui ne sont pas express ment autoris es entra ne la perte de la Garantie Sincro la cessation de la responsabilit en ce qui concerne la conformit aux normes et les cons quences relatives e L installation le service apr s vente et la maintenance doivent tre Important Se r f re des situations de risque ou Attention AVERTISSEMENT DANGER des proc dures dangereuses qui pourraient tre cause de dommages au produit ou aux appareils qui lui sont raccord s Se r f re des situations de risque ou des proc dures dangereuses qui pourraient tre cause de dommages au produit ou de l sions la personne Le symbole signale des situations de risque ou des proc dures dangereuses qui pourraient tre cause de graves l sions la personne ou de mort Le symbole signale des situations de risque ou des proc dures dangereuses qui causent de graves l sions la personne ou la mort JB4 Dicembre 2003 Rev 01 45 FRAN AIS effectu s par du personnel sp cifiquement instruit et connaissant les prescriptions des directives CE Plaque d identification Plaque des donn es lectrique
144. rweitig spezifiziert auf die sich die gelieferten Nenndaten beziehen Es ist Aufgabe des Installateurs bei sp terer Ab nderung dieses Anschlusses den neuen verwen deten Anschluss auf dem Schild mit den Maschinendaten das sich im Innern des Klemmenbrett Kastens befindet zu markieren Zur Ausf hrung des neuen Anschlusses die dieser Bedienungsanleitung beigef gten Schaltpl ne benutzen Eventuelle Ab nderungen am Anschluss d rfen ausschlie lich von Fachpersonal ausgef hrt werden EXT POT 115 Achtung Die Einstellung der Spannung auf einen Wert der ber dem f r den Generator vorgesehenen H chstwert liegt kann die Besch digung des Generators selbst bewirken Die Einstellung der Unterdrehzahl auf einen zu niedrigen Frequenzwert kann die Besch digung des Generators selbst bewirken Andererseits kann die Einstellung auf einen zu hohen Wert zu Spannungsab fall mit hohen Lasten f hren 36 JB4 Dicembre 2003 Rev Ol Der Generator wird mit Rotation im Uhrzeigersinn von der Kupplungsseite aus gesehen geliefert sofern bei Auftragserteilung nicht anderweitig spezifiziert so dass eine Phasensequenz U V W erzeugt wird Falls die Rotation nach der Auslieferung umgekehrt werden muss m ssen die entsprechenden elektrischen Schaltpl ne im Werk angefordert werden 6 4 3 berpr fung der Spannung und der Frequenz Sicherstellen dass die vom Elektro Aggregat geforder
145. s Attention La plaquette contient la mention Les don n es nominales se r f rent la connexion toile s rie et la connexion effectivement r alis e devra tre clairement coch e par l installateur parmi celles qui figurent dans la liste afin d viter tout probl me de fonc tionnement et les ventuels dommages aux personnes ou aux choses Pour la pr disposition de circuits lectriques diff rents des connexions toile s rie consulter la section et les sch mas sp cifiques report s plus loin dans ce manuel Carte AVR 46 JB4 Dicembre 2003 Rev 01 3 INTRODUCTION Nous recommandons d examiner attentivement le g n rateur au moment de la livraison pour v rifier qu il n a pas subi de dommages au cours du transport ou qu il n y a pas de parties manquantes 3 1 Contr le de la plaque signal tique Les g n rateurs de la gamme JB4 sont identifi s par une plaque signal tique Cette plaque doit tre contr l e et compar e avec les sp cifications de la commande au moment de la livraison afin de v rifier les ventuelles erreurs d exp dition ou de configuration 3 2 Positionnement de la plaque avec les donn es lectriques le num ro de s rie et l ordre de production La fourniture comprend une plaquette autocollante sur laquelle sont imprim s le num ro de s rie SN diff rent pour chaque machine et l ordre de production PO La plaquette doit tre positionn e par l ins
146. s Restmagnetismus die Selbsterregung des Generators beim Start der daher eine Restspannung Typenschild Er Elektrodatenschild Achtung Das Schild tr gt die folgende Aufschrift Die Nenndaten beziehen sich auf Stern ISerienschaltung und der effektiv realisierte Anschluss muss seitens des Installateurs un ter den in der Liste enthaltenen klar markiert werden um m gliche Funktions st rungen und eventuelle Personen oder Sachsch den zu vermeiden Zur Vorbereitung von Stromkreisen die von der Stern Serienschaltung abweichen m ssen der entsprechende Abschnitt und die spezifischen Schaltpl ne die nachstehend in dieser Bedienungsanleitung enthalten sind konsultiert werden AVR Karte JB4 Dicembre 2003 Rev 01 31 DEUTSCH Trimmer V Trimmer ST Trimmer UF H he m Leistungsfaktor 32 JB4 Dicembre 2003 Rev 01 von ca 10 der Nennspannung erzeugt Der von einem Hilfskreis gespeiste auf dem Hauptstator vorhandene AVR wirkt auf den Erreger Stator ein und regelt damit indirekt ber die Kette Erreger Rotor Diodenbr cke Hauptrotor das vom Hauptrotor erzeugte Feld Die Vorrichtung zur Spannungskontrolle regelt den Mittelwert der Spannung einer Phase und h lt sie konstant Eine Kontrollvorrichtung der Frequenz greift ein und sorgt f r die schrittweise Aberregung der Maschine wenn die Geschwindigke
147. s and remove the diode bridge Fitthe new diode bridge by locking the screws with thread adhesive and hook up the terminals Replace the rotor following in reverse the instructions given at section 74 1 As an alternative the diode bridge can be changed by merely removing the back shield as described in Changing bearing 7 4 4 Replacing components and component assemblies When assembling after changing a part repeat the above operations in reverse 8 CLEANING AND LUBRICATION Warning Any kind of cleaning work must be carried out with the gener ating set shutdown and the mains power shut off for the risk of severe hazard for persons and objects Make sure that the electricity generating set is shutdown and the mains power is shut off before cleaning the outside of the generating set with compressed air Warning Never and for no reason whatsoever use fluids or water Do not use compressed air to clean internal electrical parts since this could cause short circuits or related problems 9 DISMANTLING AND DISPOSAL Warning Only use authorised specialists All material should be eliminated in compliance with statutory regulations The generator does not present any particular risks or hazards during dis mantling To aid recovery of the material it is best to classify it by type i e electrical parts copper aluminium plastic etc 10 SPARE PARTS AND AFTERSALES 10 1 Aftersales procedure and contact addresses Our Aft
148. s are indicated on the cover page of this manual 2 1 Declaration of electromagnetic compatibility JB4 generators are constructed with criteria and materials that certify their compatibility with the following European Directives EEC 73 23 EEC 89 336 98 37 EC and later amendments CEI 2 3 EN 60034 1 EN 55011 EN 50081 1 EN 50082 1 Furthermore JB4 type generators are supplied on the following basis They shall be used as power generators or for related functions They shall be used in one of the following applications Mobile without housing for temporary power supplies Mobile with housing for temporary power supplies Onboard below deck marine use after certification On commercial vehicles freight transport cold storage etc On rolling track auxiliary power On industrial vehicles earth handling hoisting etc Stationary installation industrial factory plant Stationary installation residential commercial and light industry house office hospital Energy management cogeneration peaks in consumption Alternative energy schemes e The standard generators are designed to satisfy industrial emissions and immunity standards In the event that generators have to comply with emission limitations for residential commercial and light industrial zones some additional accessories may be necessary The installation wiring diagram requires that the generator housing is connecte
149. schemi allegati al presente manuale Le eventuali modifiche al collegamento devono essere eseguite esclusivamente da personale qualificato JB4 Dicembre 2003 Rev 01 9 ITALIANO Trimmer V EXT POT 115 Trimmer ST Attenzione Regolare la tensione ad un valore superiore a quello massimo previsto per il generatore pu causare il danneggiamento del generatore stesso Attenzione Regolare la sottovelocit ad un valore di fre quenza troppo basso pu causare il danneggia mento del generatore stesso Al contrario rego landolo ad un valore troppo alto pu causare delle cadute di tensione con carichi elevati Non toccare il generatore durante il funziona mento e subito dopo l arresto del gruppo in quanto potrebbero esservi delle superfici a temperatura elevata AVVERTENZA 10 JB4 Dicembre 2003 Rev 01 valore cercato Se ad una piccola variazione di velocit la tensione varia allora necessario regolare prima la protezione di sottovelocita Il riferimento di tensione cavetti arancioni deve essere collegato ai morsetti 0 e 115 se si preleva una tensione tra 100 e 140V impo stazione di fabbrica e ai morsetti 0 e 230 si preleva una tensione tra 200 e 280V Per ampliare del 15 circa la gamma di tensioni disponibili utilizzare il morsetto Pa invece del morsetto 0 Attenzione Regol
150. scritta I dati nominali sono riferiti al collegamento stella serie e il collegamento effettivamente rea lizzato dovr essere chiaramente contrassegnato a cura dell installatore fra quelli presenti nella lista onde evitare possibili malfunzionamenti ed eventualmente danni a persone o cose Attenzione Per la predisposizione di circuiti elettrici diversi da quello stella serie consultare la sezione e gli schemi specifici riportati nel seguito del manuale L Ufficio Tecnico Sincro a disposizione per ogni eventuale chiari mento La targhetta dati viene fornita sciolta in modo che si possa applicarla sul ge neratore nella posizione indicata in figura dopo la eventuale verniciatura La superficie di fissaggio deve essere liscia pulita e con la vernice comple tamente essiccata Per un montaggio corretto rimuovere la carta protettiva per circa 20 mm Quando questa parte stata posizionata e fatta aderire la carta protettiva pu essere progressivamente tolta mentre la targhetta viene pressata in posizione La perfetta aderenza si ottiene dopo 24 ore 4 PRINCIPIO DI FUNZIONAMENTO E CARATTERISTICHE DEL SISTEMA DI REGOLAZIONE DELLA TENSIONE Lo statore eccitatrice grazie al suo magnetismo residuo garantisce l autoec citazione del generatore alla partenza che pertanto genera una tensione residua pari a circa il 10 della tensione nominale L AVR alimentato da un circuito ausiliario presente sullo statore principale agisce sul
151. seeger e Enlever le roulement l aide d extracteurs courants Prendre le nouveau roulement et l aide d un r chauffeur le r chauffer de mani re dilater le diam tre avant de l ins rer dans le si ge de l arbre Remonter la bague seeger Positionner le bouclier sans oublier la bague lastique et introduire FRAN AIS partiellement les vis de fixation e Frapper le bouclier de mani re homog ne jusqu l insertion compl te du rotor et de la portion de caisse dans les logements respectifs e Serrer les vis de fixation du bouclier 7 4 3 Remplacement des diodes rotatives Extraire le rotor en suivant les instructions du paragraphe 7 4 1 e D connecter le pont de diodes D visser les vis et enlever le pont de diodes e Remonter le nouveau pont de diodes en fixant les vis avec un adh sif de freinage et connecter le connecteurs e Remettre en place le rotor en effectuant les op rations du paragraphe 7 4 1 dans l ordre inverse En alternative il est possible de remplacer le pont de diodes en d montant uniquement le bouclier arri re suivant la description donn e pour le remplacement du roulement 7 4 4 R assemblage de composants et de groupes de composants Pour l op ration de r assemblage effectuer les op rations pr c dentes dans l ordre inverse 8 NETTOYAGE ET LUBRIFICATION Avertissement N importe quel type d intervention de nettoyage doit tre effectu e avec le
152. sicurarsi per richieste di Assistenza in garanzia di disporre dei dati iden tificativi del generatore del suo numero di serie e del numero dell ordine di produzione riportati su etichetta adesiva posizionata come da paragrafo 3 2 del presente manuale La lista dei centri di assistenza autorizzati disponibile nel nostro sito internet www sogagroup com 11 GARANZIA La Sincro s r l garantisce qualita sicurezza e affidabilit di tutti i suoi prodotti Il periodo di garanzia contro guasti o malfunzionamenti derivati dal difetto di costruzione o dai materiali di 12 mesi a partire dalla data di consegna In nessun caso anche se l alternatore non fosse stato nel frattempo messo in servizio i termini di garanzia potranno essere prorogati Qualora durante il periodo di garanzia si manifestassero difetti di lavorazione o di montaggio di materiali la Sincro s r l riparer o sostituir a proprie spese le parti difettose nel pi breve tempo possibile La denunzia del vizio dovr avvenire entro 8 giorni dalla scoperta pena la decadenza della ga ranzia Gli interventi a carico della Sincro dovranno essere eseguiti presso lo stabilimento della stessa Tutte le spese relative al trasporto del prodotto da riparare saranno a carico del cliente La garanzia decadr qualora si manifestassero inconvenienti o guasti dovuti ad imperizia utilizzo oltre ai limiti delle prestazioni nominali se il prodotto avesse subito modifiche o se gli alternatori
153. sonal ausgef hrt werden jedem Wartungs und Reparatureingriff sicherstellen dass keine unter Spannung stehenden Teile vorhanden sind dass das Generatorgeh use die Umgebungstemperatur angenommen hat dass das Elektro Aggregat nicht gestartet werden kann auch nicht unbeabsichtigterweise und dass alle Arbeitsabl ufe korrekt ausgef hrt werden HINWEIS HINWEIS GEFAHR Den Generator w hrend des Betriebs und sofort nach dem Anhalten des Aggregats nicht ber hren da die Oberfl chen hohe Temperaturen aufweisen k nnten Der Mangel an Inspektionen und Wartung kann zu schweren Personen und oder Sachsch den f hren Die Arbeitsabl ufe zur Wartung und Lokalisierung von St rungen bringen Risiken mit sich die zu schweren Verletzun gen von Personen oder Todesf llen f hren k nnten Diese Arbeitsabl ufe d rfen daher ausschlie lich von zur elektrischen und mechanischen Assistenz bef higtem Personal ausgef hrt werden Vor jedem Wartungs und Reparatureingriff sicherstellen dass keine unter Spannung stehenden Teile vorhanden sind dass das Generatorgeh use die Umgebungstempe ratur angenommen hat dass das Elektro Aggregat nicht gestartet werden kann auch nicht unbeabsichtigterweise und dass alle Arbeitsabl ufe korrekt ausgef hrt werden JB4 Dicembre 2003 Rev 01 37 DEUTSCH Wichtig Die Lebensdauer der Lager wird durch die Arbeitsumgebung stark beeinflusst Lange Verweilzeiten an
154. t dass der Drehstromgenerator vom Motor abgetrennt wurde Zweilager und konische Version Die 8 Schrauben M10 die den Schild am Abstandsflansch befestigen abschrauben bei der Version SAE 2 ist dies nicht erforderlich Gleichm ig auf den Schild klopfen bis zur vollst ndigen Abl sung des Rotors Zweilager Version und Abl sung vom Distanzflansch konische Version Das hintere Gitter entfernen und von hinten auf den Rotor klopfen so dass das Lager aus dem Sitz geschoben wird Den Rotor auf der Kupplungsseite mit einer Schlinge sichern Den Rotor weiterhin aus dem Stator schieben und dabei weiterhin die Position der Schlinge anpassen damit die Wicklung nicht besch digt wird Einlager Version SAE Die 8 Schrauben M10 die den Schild am Abstandsflansch befestigen abschrauben bei der Version SAE 2 ist dies nicht erforderlich e Das hintere Gitter entfernen und von hinten auf den Rotor klopfen so dass das Lager aus dem Sitz geschoben wird Den Rotor auf der Kupplungsseite mit einer Schlinge sichern Den Rotor weiterhin aus dem Stator schieben und dabei weiterhin die Position der Schlinge anpassen damit die Wicklung nicht besch digt wird Zum Einbau die unter Absatz 7 4 1 beschriebenen Anweisungen umgekehrt ausf hren Achtung Vor dem Ausbau des Rotors den Rotor selbst so ausrichten dass er wahrend der Auszugsbewegung im Innern des Stators aufliegt mittels des Polschuhs Achtung Vor d
155. t troppo elevata pu causare l emulsione del grasso e favorire effetti di corrosione Importante Intense vibrazioni causate dal motore o da un errato al lineamento dei componenti del gruppo elettrogeno sottopongono il cuscinetto a sollecitazioni che ne riducono la vita AVVERTENZA AVVERTENZA PERICOLO La carenza di ispezioni e manutenzione pos sono causare gravi danni a persone e o cose Le procedure di manutenzione e di localizzazione guasti comportano dei rischi che potrebbero cau sare gravi lesioni personali o casi di decesso Tali procedure devono quindi essere eseguite esclusivamente da personale abilitato all assi stenza elettrica e meccanica Accertarsi prima di ogni intervento di manutenzione e pulizia che non vi siano parti sotto tensione che la carcassa del generatore sia a temperatura ambiente che il gruppo elettrogeno non possa essere avviato anche accidentalmente e che tutte le procedure vengano eseguite correttamente Importante La durata dei cuscinetti fortemente influenzata dalle condizioni e dall ambiente di lavoro Lunghi periodi di permanenza in un ambiente ca ratterizzato dalla presenza di vibrazioni possono danneggiare le sfere e le sedi di rotolamento La presenza di una umidit troppo elevata pu causare l emulsione del grasso e favorire effetti di corrosione Intense vibrazioni causate dal motore o da un errato allineamento dei componenti del gruppo elettrogeno sottopongo
156. t the bearing under stresses that will reduce its lifespan 24 JB4 Dicembre 2003 Rev 01 7 AFTERSALES ASSISTANCE AND MAINTENANCE Warning The maintenance and fault diagnostic procedures involve risks that may cause severe injury or even death These procedures should therefore be carried out solely by qualified electrical and me chanical specialists Before any maintenance and cleaning work make sure that there are no live parts that the generator housing has cooled to ambient temperature that the electricity generating set can not be accidentally started up and that all procedures are strictly observed 7 1 Control of windings and electrical insulation The condition of the windings can be checked by measuring their electrical resistance to earth While running this test disconnect the voltage regulator It is usually sufficient to control the main winding The readings should give a measurement of at least 2MOhm If the insu lation resistance is below this threshold the alternator alone should be oven dried at 60 80 C for 3 hours Before carrying out this operation remove the voltage regulator As an alternative to oven drying hot air at 60 80 C can be blown through the alternator for at least 1 hour 7 2 Control of bearings The bearings are sealed and maintenance free During maintenance control the condition the bearings and check that no grease has leaked the lifespan of the bearings depends on the vibrations
157. t to exceed 4000N For greater shaft lengths the acceptable loads can be requested directly from the Sincro Technical Office Alignment of single bearing generators is critical because it may give rise to vibrations along the coupling between motor and generator For this pur pose special attention must be given to the alternator to motor assembly providing a solid base and implementing anti vibration plugs to support the motor alternator assembly The terminal box contains the insulated terminals for connecting the line and neutral and for the earth connection ENGLISH The neutral is NOT connected to the housing Warning The generator is supplied without a connection to earth to make this connection refer to relevant local regulations An inefficient earth connection or safety cut out can cause injury or death The generator fault currents are available on request to help the plant en gineer in sizing the plant and its components Warning An error in installation use maintenance or replacement of parts can cause severe injury or death not to mention damage to the machinery All work on electrical and or mechanical parts must be carried out by a qualified specialist 6 INSTALLATION 6 1 Lifting Lift and handle the generator with suitable equipment either on a pallet or by the lifting lugs located on the generator in the positions indicated in the figure When lifting the generator use equipment with a loadbearing
158. talaci n ser conforme a las disposiciones de las Directivas Europeas y ser llevada a cabo nica y exclusivamente por personal cualificado e No se pondr en marcha el generador de estar desmontados tanto las tapas de protecci n como los paneles de acceso o los de revestimiento de la caja de terminaci n Antes de realizar cualquier intervenci n de mantenimiento se desconectar n los circuitos de arranque del motor Deshabilitar los circuitos de cierre y o instalar placas de aviso en cada interruptor autom tico utilizado normalmente para la conexi n con la red o con otros generadores para impedir su cierre accidental Usar exclusivamente partes originales para cualqueir operaci n de mantenimiento o reparaci n De no respetarse esta indicaci n Sincro S r l declina toda responsabilidad respecto de la seguridad y buen funcionamiento del generador Instruir al usuario de la instalaci n en la gesti n uso y mantenimiento del generador No estar permitido todo aquello no previsto expresamente en estas instrucciones En este manual vienen empleados algunos s mbolos o convenciones que tienen un significado preciso A continuaci n ser n definidos de manera un voca Importante Se refiere a situaciones de riesgo o procedimientos peligrosos que podr an ocasionar da os al producto o a los aparatos conectados ESPANOL jAtencion Se refiere a situaciones de riesgo o procedimientos peligrosos qu
159. tallateur dans la position indiqu e sur la figure de mani re tre facilement lisible le num ro de s rie et l ordre de production en effet sont des donn es qui font partie int grante des proc dures mettre en uvre pour la demande d interventions de service apr s vente Le g n rateur est fourni avec une autre plaquette autocollante contenant les donn es et les sp cifications lectriques ainsi que la liste des connexions possibles Attention La plaquette contient la mention Les donn es nominales se r f rent la connexion toile s rie et la connexion effectivement r alis e devra tre clairement coch e par l installateur parmi celles qui figurent dans la liste afin d viter tout probl me de fonctionnement et les ventuels dommages aux personnes ou aux choses Attention Pour la pr disposition de circuits lectriques diff rents des connexions toile s rie consulter la section et les sch mas sp cifiques report s plus loin dans ce manuel Le Service Technique Sincro est disposition pour toute pr cision ventuelle La plaquette des donn es est fournie s par e de la machine de mani re pouvoir l appliquer sur le g n rateur dans la position indiqu e sur la figure apr s l ventuelle peinture La surface de fixation doit tre lisse propre et avec la peinture compl tement s che Pour un montage correct enlever le papier de protection sur environ 20mm Quand cette partie a t pos
160. tar el alternador aplicando a los bornes de la excitatriz una tensi n de 6 12 voltios por un segundo respetando la polaridad 68 JB4 Dicembre 2003 Rev 01 Desmontar la rejilla posterior y golpear el rotor posteriormente para empujar el cojinete fuera del alojamiento Sostener el rotor con una eslinga por el lado de acoplamiento Seguir empujando el rotor fuera del estator adaptando continuamente la posici n de la eslinga a fin de no estropear el devanado Para la inserci n seguir las instrucciones del apartado 7 4 1 pero en secuencia inversa Atenci n Antes de extraer el rotor orientarlo de forma tal que durante el movimiento de extracci n el rotor se apoye en el interior del estator mediante la zapata polar Advertencia Al volver a montar el rotor el alternador puede perder el magnetismo residual que permite la autoexcitaci n Por tanto antes de poner en marcha el grupo ser necesario volver a excitar el alternador aplicando a los bornes de la excitatriz una tensi n de 6 12 voltios por un segundo respetando la polaridad 7 4 2 Sustituci n del cojinete Tener como referencia el apartado 7 4 1 e Quitar la arandela el stica tipo seeger e Quitar el los cojinetes mediante extractores comunes e Coger el los nuevos cojinetes y calentarlos con un calentador para que se dilate el di metro antes de insertarlo en el alojameinto del eje Volver a montar la arandela seeger e Montar otra vez el r
161. ten Spannungs und Frequenzwerte den auf dem Typenschild des Generators angegebenen entsprechen Warnhinweis Der Generator verl sst die Produktionslinien mit einer Stern Serienschaltung sofern bei Auftragserteilung nicht anderweitig spezifiziert auf die sich die gelieferten Nenndaten beziehen Es ist Aufgabe des Installateurs bei sp terer Ab nderung dieses Anschlusses den neuen verwendeten Anschluss auf dem Schild mit den Maschinendaten das sich im Innern des Klemmenbrett Kastens befindet zu markieren Zur Ausf hrung des neuen Anschlusses die dieser Bedienungsanleitung beigef gten Schaltpl ne benutzen Warnhinweis Eventuelle Ab nderungen am Anschluss d rfen ausschlie lich von Fachpersonal ausgef hrt werden 6 4 4 Einstellung Karte AVR Um die Einstellungen der Steuervorrichtung AVR zu w hlen begibt man sich zur Steuerkarte nachdem man die Abdeckungen abgenommen hat Die meisten Einstellungen werden im Werk vorgenommen auf Werte die dazu bestimmt sind bei den anf nglichen Funktionsproben zufriedenstellende Ergebnisse zu gew hrleisten Weitere Einstellungen k nnten sich als erforderlich erweisen um eine optimale Funktion unter spezifischen Betriebsbedingungen zu gew hrleisten Wenn der Drehstromgenerator bei 50Hz arbeiten soll muss die Br cke die die mit 60Hz markierten Endverschl sse kurzschlie t angeschlossen bleiben soll er bei 60Hz arbeiten muss die Br cke entfernt werden Es besteht die M glich
162. tenzione possono causare gravi danni a persone e o cose In conseguenza di quanto sopra scritto si richiede che ogni operazione di carattere elettrico o meccanico venga eseguita con l intervento di personale qualificato 7 ASSISTENZA E MANUTENZIONE Avvertenza Le procedure di manutenzione e di localizzazione guasti comportano dei rischi che potrebbero causare gravi lesioni personali o casi di decesso Tali procedure devono quindi essere eseguite esclu sivamente da personale abilitato all assistenza elettrica e meccanica Accertarsi prima di ogni intervento di manutenzione e pulizia che non vi siano parti sotto tensione che la carcassa del generatore sia a temperatura ambiente che il gruppo elettrogeno non possa essere avviato anche accidentalmente e che tutte le procedure vengano ese guite correttamente 7 1 Controllo degli avvolgimenti e dello stato di isolamento Lo stato degli avvolgimenti verificabile misurandone la resistenza elettrica verso massa Durante la prova il regolatore di tensione dovr essere scolle gato In generale sufficiente controllare il solo avvolgimento principale valori rilevati devono essere superiori a 2MOhm Nel caso in cui la resi stenza d isolamento risulti inferiore si dovr procedere alla essiccazione in forno del solo alternatore ad una temperatura compresa fra 60 e 80 C per 3 ore Prima di eseguire tale operazione occorre rimuovere il regolatore di tensione In alternativa all essicc
163. tinados exclusivamente para el izado de dicho aparato y no del entero grupo electr geno Los generadores monocojinete ser n izados y desplazados manteniendo la m quina en posici n horizontal con el fin de evitar en el caso de que la operaci n no se lleve a cabo correctamente que se salga el rotor y se pueda estropear con consecuencias graves para las personas 6 2 Fijaci n al motor 6 2 1 Montaje forma SAE ver figura Atenci n Antes del montaje verificar que los alojamientos de acoplamiento tanto del generador como del motor sean regulares y est n bien limpios e Quitar la barra de fijaci n del rotor e Quitar las rejillas de protecci n 6 y las tapas de pl stico 7 puestas en la campana e Controlar que el di metro del disco 3 corresponda al di metro de alojamiento en el volante 2 Fijar el generador al motor bloqueando la campana SAE 1 controlar que los orificios del disco coincidan con los del volante Verificar que el disco est apoyado sobre el volante y para ello golpear axialmente el rotor con un martillo de pl stico y un tamp n Fijar el disco al volante Verificar que el rotor y el estator de la excitatriz est n alineados entre s perfectamente Sostener el grupo con antivibratorios 5 teniendo cuidado de la correcta nivelaci n entre el motor y el generador Volver a montar las rejillas y las tapas 6 2 2 Desmontaje forma SAE Para el desmontaje hay que seguir
164. tividad ser necesario controlar la resistencia de aislamiento hacia la masa de todos los devanados se recomienda desconectar la corriente el ctrica del regulador antes de ejecutar dicha prueba los valores detectados deber n ser superiores a 2MOhm En el caso de que no se d esta condici n se secar en el horno s lo el alternador a 60 80 C por 3 horas Antes de llevar a cabo esta operaci n es necesario desmontar el regulador de tensi n Como alternativa al secado en horno se puede soplar aire caliente a 60 80 C a trav s del alternador al menos por 1 hora De estar instalada la m quina dentro de una estructura cerrada habr que asegurarse que la temperatura del aire de enfriamiento enviada al generador no sea superior a la nominal prevista La estructura estar realizada de forma tal que la toma de aire del motor puesta en la estructura est separada de la toma del generador sobretodo si la aspiraci n de aire en la estructura est asegurada con el ventilador de enfriamiento Asimismo la toma de aire del generador estar realizada de modo que impida infiltraciones de humedad con un filtro adecuado La Trimmer ST Altitud m Factor de potencia Trimmer V Trimmer UF 45 50 55 0 96 0 82 0 88 1500 2000 2500 0 96 0 93 0 90 08 07 0 6 1 0 93 0 88 JB4 Dicembre 2003 Rev 01 61 ESPA OL Importante Tanto la re
165. to Para condiciones de trabajo espec ficas podr a ser necesario realizar otras regulaciones para el funcionamiento ptimo Si el alternador debe funcionar a 50Hz el puente que cortocircuita los bornes marcados con 60Hz permanecer conectado de funcionar a 60Hz se eliminar el puente ESPANOL Se puede modificar la tensi n de salida usando el potenci metro Con el grupo en movimiento con velocidad nominal regular hasta obtener el valor deseado De variar la tensi n al variar ligeramente la velocidad ser entonces necesario regular primero la protecci n de subvelocidad La referencia de tensi n cables anaranjados se deber conectar alos bornes 0 y 115 si se toma una tensi n entre 100 y 140V configuraci n de f brica alos bornes 230 si se toma una tensi n entre 200 y 280V Para ampliar de aprox el 15 la gama de tensiones disponibles utilizar el borne en vez del borne 0 Atenci n regular la tensi n con un valor superior al m ximo previsto para el generador puede ocasionar da os a ste Regulaci n de la subvelocidad a 50 60 Hz hacer girar el grupo regul ndolo para obtener una frecuencia de 46 56 Hz Girar el trimmer UF hasta que la tensi n empiece a bajar Llevar el grupo a la velocidad nominal Atenci n regular la subvelocidad con un valor de frecuencia demasiado bajo puede ocasionar da os al generador Al cont
166. tore sia stato staccato dal motore Versione bicuscinetto e Svitare nr 8 viti M10 che bloccano lo scudo alla flangia distanziale per la versione SAE 2 non necessario e Colpire in maniera omogenea lo scudo fino al completo distacco dal rotore Togliere la griglia posteriore e colpire il rotore posteriormente in modo da spingere il cuscinetto fuori dalla sede e Supportare il rotore con un imbragatura dal lato accoppiamento e Continuare a spingere il rotore fuori dallo statore continuando ad adat tare la posizione dell imbragatura in modo da non danneggiare l avvolgi mento Versione monocuscinetto SAE e Svitare nr 8 viti M10 che bloccano lo scudo alla flangia distanziale per la versione SAE 2 non necessario Togliere la griglia posteriore e colpire il rotore posteriormente in modo da spingere il cuscinetto fuori dalla sede e Supportare il rotore con un imbragatura dal lato accoppiamento e Continuare a spingere il rotore fuori dallo statore continuando ad adattare la posizione dell imbragatura in modo da non danneggiare l avvolgimento ITALIANO Per l inserimento seguire a ritroso le istruzioni fornite al paragrafo 7 4 1 Attenzione Preventivamente all estrazione del rotore orientare il rotore stesso in modo che durante il movimento di estrazione il rotore si ap poggi all interno dello statore mediante la scarpa polare Avvertenza Quando viene reinserito il rotore l alternatore pu pe
167. tra con rotaci n en el sentido de las agujas del reloj mirando hacia el lado acoplamiento de no especificarse diversamente en el pedido de manera que se produzca una secuencia de fase U V W De tenerse que invertir la rotaci n despu s de la entrega pedir al Fabricante los esquemas el ctricos correspondientes 6 4 3 Verificaci n de tensi n y de frecuencia Controlar que los niveles de tensi n y frecuencia requeridos por el grupo electr geno correspondan a los indicados en la placa datos del generador Advertencia El generador sale de las l neas de producci n con una conexi n estrella serie de no especificarse diversamente en el pedido respecto del cual se suministran los datos nominales En el caso de modificaci n de dicha conexi n el instalador se encargar de marcar la nueva conexi n indicada en la placa de datos m quina puesta en el interior de la caja de bornes Para realizar la nueva conexi n tener como referencia los esquemas que se adjuntan con el presente manual Advertencia Las posibles modificaciones de la conexi n ser n realizadas nica y exclusivamente por personal cualificado 6 4 4 Regulaci n de la tarjeta AVR Para elegir las configuraciones del dispositivo de mando AVR acceder a la tarjeta de control despu s de haber quitado del recubrimiento La mayor parte de las regulaciones se efect an en la f brica con valores que aseguran resultados satisfactorios en las pruebas iniciales de funcionamien
168. trog ne il n est pas possible d appliquer en phase de construction toutes les tiquettes de signalisation n cessaires sur le g n rateur Ces tiquettes qui indiquent le danger potentiel et le risque li la pr sence de composants sous tension sont fournies en vrac et doivent tre appliqu es par le constructeur du groupe lectrog ne dans les positions indiqu es dans la figure ci contre une fois que l assemblage du groupe est termin Les g n rateurs de la gamme JB4 sont projet s pour fonctionner une temp rature maximum de 40 C et une altitude maximum de 1000m Dans ces limites de temp rature et d altitude ils fournissent les performances nominales indiqu es sur la plaque Pour des temp ratures sup rieures 40 C et ou des altitudes sup rieures 1000m des r ductions de performances se v rifient voir tableau Il est bon de signaler au Bureau Technique Sincro que le g n rateur sera amen fonctionner dans des conditions ambiantes pires que celles qui Temp ambiante 40 45 50 55 sont mentionn es plus haut 1 0 96 0 82 0 88 Les g n rateurs sont munis d un syst me de ventilation air de blindages Aude m 1000 1500 2000 2500 de protection et d une carcasse antiruissellement ils ne sont pas adaptes A __ ___ pour l installation en plein air moins d tre prot g s par des couvertures Facteur de puissance 1 08 07 06 ad quates Durant le s jour en magasin
169. trol that the voltage and frequency levels required by the electricity generating set correspond to the generator data plate Warning The generator leaves the production line with a star series connection unless otherwise specified on order which are used as reference for its nominal data In the event of any subsequent changes the installer must undertake to mark the new connection used on the machine data plate located inside the terminal box To change con nection consult the diagrams in the appendix of this manual Warning All changes in connection must be carried out solely by a qualified specialist 6 4 4 AVR board settings To select the AVR settings access the control board after removing the cover Most adjustments are factory set to ensure satisfactory results in the operating tests on commissioning Further adjustments may be necessary to ensure optimum operation under specific working conditions If the alternator has to operate at 50Hz the jumper across the terminals marked 60H has to be left in place if it has to operate at 60Hz this jumper should be removed ENGLISH The output voltage can be changed by adjusting potentiometer V Take the generating set to its nominal speed and turn until the required voltage is obtained If a small variation in speed causes a change in voltage then the bottom speed protection should first be calibrated The voltage reference orange wires should be connected
170. troles preliminares 6 4 1 Control del aislamiento Antes de poner en servicio el grupo electr geno o bien despu s de largos periodos de inactividad controlar la resistencia de aislamiento hacia la masa de los devanados Atenci n Desconectar el regulador de tensi n AVR antes de efectuar la medici n Los valores detectados ser n superiores a 2MOhm En el caso la resistencia de aislamiento resulte inferior se proceder a secar el alternador en el horno con una temperatura comprendida entre 60 y 80 C por 3 horas Antes de realizar esta operaci n es necesario desmontar el regulador de tensi n Como alternativa al secado en horno es posible soplar aire caliente a 60 80 C a trav s del alternador al menos por 1 hora Importante Los devanados han sido comprobados en alta tensi n durante la producci n M s pruebas con alta tensi n pueden deteriorar el aislamiento y por tanto reducir su vida operativa De ser necesaria una prueba con alta tensi n para la aceptaci n por parte del cliente se efectuar n las pruebas con niveles de tensi n reducidos 6 4 2 Sentido de rotaci n Las m quinas forma SAE est n provistas de ventilador unidireccional y por tanto son aptas para girar solamente en el sentido de las agujas del reloj visto desde el lado de acoplamiento Las m quinas forma B3 est n provistas de ventilador de palas radiales y por tanto pueden girar en los dos sentidos de direcci n El generador se suminis
171. ut prior notice
172. utenzione al fine di prevenire eventuali malfun zionamenti del generatore ed evitare situazioni di pericolo per l utente e Smaltire i materiali di imballo plastica cartone polistirolo ecc secondo quanto previsto dalle norme vigenti e Conservare le istruzioni per allegarle al fascicolo tecnico e per consulta zioni future e Questo prodotto stato progettato e costruito esclusivamente per l utilizzo indicato in questa documentazione Usi non indicati in questa document azione potrebbero essere fonte di danni al prodotto e fonte di pericolo e La Sincro S r l declina qualsiasi responsabilit derivante dall uso im proprio o diverso da quello per cui destinato ed indicato nella presente documentazione e Non installare il prodotto in atmosfera potenzialmente esplosiva Gli elementi costruttivi dell impianto devono essere in accordo con le Direttive Europee Per tutti i Paesi extra CEE oltre alle norme nazionali vigenti per un buon livello di sicurezza opportuno rispettare anche le norme sopracitate L installazione deve essere in accordo con quanto previsto dalle Diretti ve Europee e deve essere eseguita esclusivamente da personale quali ficato e Non avviare il generatore se le calotte di protezione i pannelli di accesso o quelli di copertura della cassetta di terminazione sono stati rimossi Prima di eseguire qualsiasi intervento di manutenzione disabilitare i circuiti di avviamento del motore Disabi
173. ventilateur unidirectionnel et sont donc adapt es pour tourner uniquement dans le sens des aiguilles d une montre vu c t accouplement Les machines avec construction B3 sont munies de ventilateur pales radiales et peuvent donc fonctionner dans les deux sens de rotation Le g n rateur est fourni avec la rotation dans le sens des aiguilles d une montre en regardant le c t accouplement moins de sp cifications diff rentes au moment de la commande de mani re produire une s quence de phase U V W Si la rotation doit tre invers e apr s la livraison demander Sincro les sch mas lectriques 6 4 3 V rification de tension et de fr quence Contr ler que les niveaux de tension et de fr quence demand s par le groupe lectrog ne correspondent ceux qui figurent sur la plaquette du g n rateur Avertissement Le g n rateur sort des cha nes de production avec une connexion toile s rie moins de sp cifications diff rentes au moment de la commande laquelle se r f rent les donn es nominales En cas de modification successive de cette connexion l installateur est tenu de cocher la nouvelle connexion utilis e sur la plaquette FRAN AIS des donn es machine pr sente l int rieur de la bo te bornes Pour effectuer la nouvelle connexion se servir des sch mas joints au pr sent manuel Avertissement Les ventuelles modifications de la connexion doivent tre effectu es exclusiv
174. x prescriptions relatives la s curit Pour les communications avec Sincro S r l nous vous prions de toujours citer le type et le code du g n rateur se trouvant sur l tiquette pr sente dans l emballage Par ailleurs si cause de probl mes de fonctionnement ou d une panne quelconque de la machine vous devez faire appel notre Service Apr s vente nous vous prions de mentionner galement le num ro de s rie SN et l ordre de production PO ATTENTION Une installation erron e ou une utilisation impropre du produit peuvent entra ner des dommages aux personnes ou aux choses e S en tenir scrupuleusement ce qui est d crit dans le Manuel d Instructions et de Maintenance qui a pour but d indiquer les conditions correctes d installation utilisation et maintenance afin de pr venir les ventuels probl mes de fonctionnement du g n rateur et d viter les situations de danger pour Putilisateur e Mettre au rebut les mat riaux d emballage plastique carton polystyr ne expans etc suivant les prescriptions des normes en vigueur e Conserver les instructions pour les joindre au fascicule technique et pour des consultations futures e Ce produit a t projet et construit exclusivement pour l utilisation indiqu e dans cette documentation Les utilisations non indiqu es dans cette documentation pourraient endommager le produit et tre source de danger Sincro S r l d cline toute responsabilit
175. zze 3 Loc Cereda 36073 Cornedo Vicentino VI Italy dichiara sotto la propria responsabilit che i genera tori sono costruiti e collaudati in accordo alle norme di seguito indicate declares under its own respon sibility that the generators erkl rt unter der eigenen Verantwortung da der Bau und die Abnahme der Generatoren d clare sous sa propre respon sabilit que les generateurs Serie JB4 Series JB4 Baureihe JB4 S rie JB4 Serie JB4 have been manufactured and tested in compliance with the following standards den nachstehenden Vorschriften entspricht sont construits et test s dans le respect des normes indiqu es ci apr s declara bajo la propia respon sabilidad que los generatores han sido fabricados y probados siguiendo la normativa que se detalla a continuaci n e risultano conformi 1 ai requisiti generali di sicu rezza stabiliti dalla Direttiva Bassa Tensione del 19 Feb braio 1973 73 23 CEE rece pita in Italia con la legge n 791 del 18 Ottobre 1977 2 alla Direttiva 89 336 CEE mod dalla 93 68 CEE riguar dante il ravvicinamento delle le gislazioni degli Stati membri in materia di compatibilit elettromagnetica La verifica di compatibilita stata condotta in base alle seguenti norme CEI EN 60034 1 2 3 NF 51 100 VDE 0530 BS 4999 5000 CEI EN 60204 1 44 5 EN 292 1 292 2 IEC 34 1 34 5 and thereby conform to