Home
Swiss PiezoClast®
Contents
1. Evaluation du traitement par ondes de CNOC iii ant 28 Principe de fonctionnement de la pi ce MAN ir as 30 D roulement du traitement avec la pi ce main 32 Therapie des trigger points par ondes de choc EL BS circa 37 Indications ee 37 Orthop die ESWT 38 Postures recommand es ssssssessorssnnnn 38 Recommandation pour le traitement par ondes de chocs ESWT 40 Retraitetmel E en reese eterne tre ra eR ee 42 Retraitement de l appareil 42 Retraitement de la p dale 42 Retraitement de la piece main 44 INHALT Installieren ls Stromanschluss Aufstecken des Fu schalters Montageanweisung Befestigungssatz f r Swiss PiezoClast optional 6 Bedienen des Ger tes 10 ele Wel EE 10 Vorbereiten des Handst cks 12 Aufstecken des Handst cks 16 Sto wellenintensit t einstellen ald Stosswellenfrequenz einstellen 20 Voreinstellung der Anzahl der zu applizierenden StoBwellen 22 Behandlungsablauf n 24 Fufsschalter ica 326 Auswertung der Sto wellentherapie 28 Funktionsprinzip des PiezoClast Handstcks is 30 Behandlungsablauf mit dem Handst ck 32 Trigger Punkt Sto wellen The
2. V lj en gelplatta som motsvarar det f rutbest mda penetreringsdjupet Det p gelplattan A angivna numret motsvarar penetreringsdjupet E f r terapifokus F i mm se Abb 1 och 2 Ju h gre gelplattan r desto mindre r penetre ringsdjupet E se Abb 1 och 2 33 The deepest penetration of approx 40 mm is achieved by using the lowest e flattest gel pad no identification Apply ultrasound gel evenly and free of air bubbles to the gel pad and the patient Place the handpiece at a right angle relative to the body surface onto the point of indication The centering tip B and the guidance lines C facilitate orientation and alignment when placing the handpiece onto the area to be treated Reprocess the handpiece after each use in accordance with Chapter Reprocessing Use only ultrasound gels certified for use on patients Follow the gel manufacturer s instruc tions 34 La plus grande profondeur de p n tration a atteindre est de 40 mm Ceci impose l emploi du gel pad le plus petit sans marquage Appliquer le gel de contact de mani re uniforme et exempte de bulles d air sur le gel pad et le patient Positionner la piece a main de mani re perpen diculaire sur la zone traiter La pointe de centrage B et les lignes de rep re C sont pr vues pour faciliter l orientation et l ali gnement de la pi ce main au moment o elle est plac e sur la zone traiter La pi ce ma
3. Zur Vermeidung von Personensch den oder Sachsch den am Swiss PiezoClast beachten Sie bitte die folgenden Hinweise Gefahr Gefahr von Personensch den Achtung Drohende Sach und Umweltsch den Hinweis N tzliche Zusatzinformationen und Anwendungstipps Verboten Erlaubt AX Pb PRESENTACI N DEL MANUAL Estas instrucciones de empleo sirven para garantizar una instalaci n y uso correctos de este producto Lea estas instrucciones de empleo atentamente ya que explican todos los detalles y procedimientos m s importantes Preste especial atenci n a las precauciones de seguridad Tenga siempre a mano este documento Referirse a los instrucciones de empleo este producto requiere precauciones especiales referentes a compatibilidad electromagn tica y debe instalarse y ponerse en funcionamiento conforme al manual de Electromagnetic compa tibility Para evitar posibles lesiones en el paciente o usuario o da os al PiezoClast n tense las direc trices correspondientes Peligro Riesgo de lesiones en el paciente o usuario Precauci n Riesgo de da os en el dispositivo o medioambientales Observaci n Informaci n y consejos tiles adicionales Prohibido Autorizado AX RP INFORMAZIONI SU QUESTO MANUALE Le presenti istruzioni operative consentono la corretta installazione e utilizzo di questo prodotto Leggere attentamente queste istruzioni operative poich spiegano tutti i dettagli e le procedur
4. 28 Gel pad replaceable 29 Twist lock ring for gel pad 30 Handpiece 31 Gel pad assortment 32 PiezoClast DolorClast mounting kit 33 Handpiece test cylinder complete 34 Handpiece holder table top EMS supplies this unit with various accessories The Packing list shows exactly what your unit includes COMPOSANTS 1 Appareil 2 Affichage de l intensit de l onde de choc 3 Affichage compteur d ondes de choc et message d information et d erreur 4 Affichage fr quence d impulsion 5 Touche augmenter l intensit de l onde de choc 6 Touche baisser l intensit de l onde de choc 7 Touche augmenter la fr quence d impulsion 8 Touche baisser la fr quence d impulsion 9 Touche veille 10 T moin veille Touche pr s lection du nombre d ondes de choc Touche de remise z ro Touche de Fonction 1 Touche de Fonction 2 Connecteur pour la pi ce main Support de pi ce main Connecteur P dale de commande 19 C ble secteur 20 Interrupteur g n ral 21 Prise de secteur avec porte fusibles 22 Connecteur pour la p dale de commande 23 Interface des donn es uniquement pour entretien 24 Connecteur de compensation de potentiel 25 Ventilateur 26 Fusibles 27 Bouteille de gel 28 Gel pad interchangeable 29 Bague baionnette pour gel pad 30 Piece main 31 Assortiment de Gel pad 32 Kit de montage PiezoClast DolorClast 33 Cylindre test de pi ce main complet 34 Support de pi ce main de table
5. Always examine the product for damage before commencing treatment Damaged acces sories or a damaged unit must not be used and must be replaced Use original EMS spare parts and accessories only This product must only be repaired by an approved EMS repair center 60 A Risque d explosion n utilisez pas ce produit en pr sence d anesth siques ou de gaz inflam mables A Ce produit ne doit tre utilis que par un personnel qualifi et form V rifier avant chaque traitement que le produit ne pr sente pas de d fauts Un acces soire ou un appareil endommag ne doit plus tre utilis Il doit tre remplac N utilisez que des pi ces et des accessoires EMS d origine Faites r parer ce produit exclusivement par un centre de r paration agr par EMS A Explosionsgefahr verwenden Sie dieses Produkt nicht in Gegenwart von entz ndlichen An sthetika oder Gasen A Dieses Produkt darf nur von ausgebildetem und qualifiziertem Personal benutzt werden A berpr fen Sie Ihr Produkt vor jeder Behandlung auf Sch den Besch digtes Zubeh r oder ein besch digtes Ger t darf nicht mehr verwendet werden und ist zu ersetzen Verwenden Sie ausschliesslich original EMS Ersatzteile oder Zubeh r N Lassen Sie dieses Produkt ausschliesslich durch EMS oder durch einen von EMS autori sierten H ndler warten oder instandsetzen Mm Riesgo de explosi n no utilice este producto en combinaci n con anest sicos o gases
6. 43 Reprocesamiento del pedal 43 Reprocesamiento del MaNgO 45 INDICE Installazione 3 Collegamento energia da Fornitura del pedale 5 Istruzioni per il montaggio set di fissaggio per Swiss PiezoClast opzionale Us dell UNit carini COMTO UN EC Preparativi del manipolo Connessione del manipolo Regolare l intensit dell onda d urto z Regolare la frequenza d impulso Preimpostazione dell insieme di onde d urto da applicare n ns 23 Ciclo di trattamento gt P dales emet E 27 Valutazione della terapia ad onde d urto 29 Principio di funzionamento del manipolo 31 Ciclo di trattamento con il manipolo 33 Terapia ad onde d urto su trigger point TPST ensi 37 Indicazioni Ol leen 37 Ortopedico ESWT u 39 Esempi di posizione 39 Indicazioni per la terapia ad onde d urto ESWT ee e cer ep eee ma 41 Ritrattamento Ritrattamento del apparecchio 43 Ritrattamento del pedale 43 Ritrattamento del manipolo 45 INNEH LL Installation essen 3 Anslutning till str mk lla tad Ansluta eN pedal ts 5 Monteringsanvisning f r fastg ringssats f r Swiss PiezoClast tillval
7. Contact service departmen Contact service departmen Contact service departmen Contact service departmen Contact service departmen Contact service departmen Connect approved handpiece Actuate the F2 function button blinking is deactivated Blinking cannot be deactivated Connect a new handpiece MESURE PRENDRE EN CAS D INCIDENT Messages d information et d erreur apparaissant dans l affichage Message APPL Err 1 Err 2 Err 3 Err 4 Err 5 Err 6 Err 7 Err 8 Err 9 Err 10 Err 11 Err 12 L affichage des ondes de choc se met clignoter Affichage ondes de choc affiche End Cause La pi ce main n est pas raccord e ou la connexion a t interrompue pendant le d clenchement de l onde de choc Panne dans le g n rateur haute tension Panne dans le g n rateur haute tension Panne dans le g n rateur haute tension Panne dans le g n rateur haute tension ou d fectuosit du c ble de communication haute tension entre le pro cesseur e card et g n rateur haute tension D fectuosit du c ble de communication haute tension entre le processeur e card et g n rateur haute tension D fectuosit du module de sauvegarde de l appareil D fectuosit de la pi ce main Erreur sur le processeur e card Erreur sur le processeur e card Erreur de donn es dans le module de sauvegarde de la pi ce main La pi ce main n est pas programm e La pi ce main n a pas
8. EMS SA CH 1260 Nyon Suisse RICHARD WOLF GmbH 75438 Knittlingen Allemagne Piece a main F10 G4 pour Swiss PiezoClast Class I Partie appliqu e du type B IP 20 94 100 mm 0 03 a 0 4 mJ mm 11 5 82 2 MPa de 1 2 2 8 mm de 5 0 14 1 mm 58 mm de 1 8 Hz 20 niveaux 9 54 mJ de 5 40 mm approx 1 2 kg approx 2 7 Ibs 10 C 35 C 30 75 d humidit relative pression atm de 700 hPa 1060 hPa 5 C 40 C 10 95 d humidit relative pression atm 700 hPa 1060 hPa 77 TECHNISCHE DATEN Beschreibung des Ger tes Vertreiber Hersteller Modell Klassifikation EN 60601 1 Klassifikation 93 42 EWG Stromversorgung Spannung Stromversorgung Frequenz Leistungsaufnahme Ger uschpegel Sicherung Betriebsart Gewicht Abmessung BxHxT Betriebsbedingungen Lager und Transportbedingungen 78 EMS SA CH 1260 Nyon Schweiz RICHARD WOLF GmbH 75438 Knittlingen Deutschland Swiss PiezoClast Klasse Anwendungsteil Typ B IP 20 f r das Ger t IP X8 f r den elektrischen Fu schalter Modus Dauerbetrieb Klasse IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A T3 15L Dauerimpulsbetrieb Wiederholfrequenz 1 20 Hz ca 14 5 kg ca 30 8 Ibs 395 mm x 400 mm x 170 mm 10 C bis 35 C 30 bis 75 rel Feuchte Luftdruck 700 hPa bis 1060 hPa 5 C bis 40 C 10 bis 90 rel Feuchte Luftdruck 700 hPa bis 1060 hPa Beschreibun
9. Rem dier l absence ou l illisibilit d un marquage etd une inscription risquant de causer une manipu lation ou un retraitement inad quats V rifier l tat parfait de la surface de contact de la pi ce main Proc der au contr le de la pi ce main en suivant les instructions portant sur la pi ce main dans le chapitre Maintenance Essai fonctionnel Raccorder la pi ce main l appareil et mettre l appareil en service en actionnant l interrupteur principal L appareil proc de l auto test Si aucune erreur n est affich e le Swiss Piezo Clast et la pi ce main connect e sont pr ts fonctionner BEDIENEN DES GER TES Kontrollen N Die Kontrollen vor und nach jeder Anwendung durchf hren Produkte die besch digt oder unvollst ndig sind bzw lose Teile aufweisen nicht mehr verwenden Besch digte Produkte mit den losen Teilen zur Reparatur einsenden Keine eigenen Reparaturversuche vornehmen Sichtkontrolle Ger t und Zubeh r auf Besch digungen lose oder fehlende Teile hygienischen Zustand und Vollst ndigkeit berpr fen Netzanschlussleitungen auf Besch digungen berpr fen Aufschriften und Kennzeichnungen die zum sicheren bestimmungsgem en Gebrauch erfor derlich sind m ssen lesbar sein Fehlende oder nicht mehr lesbare Aufschriften und Kennzeichnungen die zu Fehlern in der Handhabung oder Aufbereitung f hren m ssen wieder hergestellt werden Kont
10. t valid e pour l appareil La pi ce main atteindra bient t sa dur e de vie pr vue Il ne reste plus qu environ 100 000 ondes de choc La pi ce main atteindra bient t sa dur e de vie pr vue Il ne reste plus qu environ 50000 ondes de choc La pi ce main a atteint sa dur e de vie pr vue Le d clenchement d ondes de choc n est plus possible Action corrective Raccorder la pi ce main Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Informer le Service AV Raccorder une pi ce main valid e Actionner la touche de FONCTION F2 pour d sactiver le clignotement Le clignotement ne peut plus tre d sactiv Raccorder une pi ce main neuve Asi les probl mes ne peuvent tre r solus selon la table ci dessous informer le Service Apr s vente ou renvoyer l appareil l usine pour r paration Ne pas proc der une tentative de r paration Panne de l appareil L appareil ne fonctionne pas Il n y a pas d onde de choc Cause ventuelle Action corrective L interrupteur principal n a pas t actionn Le cordon d alimentation n est pas branch I n y a pas de tension secteur Le fusible secteur est d fectueux Remplacer le fusible secteur La p dale n est pas branch e ou
11. Clase IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A T 3 15 L Modo de impulso continuo Rango de repetitici n 1 20 Hz unos 14 5 kg unos 30 8 Ibs 395 mm x 400 mm x 170 mm 10 C a 35 C humedad relativa 30 a 75 presi n atmosf rica 700 hPa a 1060 hPa 5 C a 40 C humedad relativa 10 a 90 presi n atmosf rica 700 hPa a 1060 hPa Denominaci n del mango Distribuidor Fabricante Modelo Clasificaci n EN 60601 1 ngulo de apertura Di metro de apertura Densidad de flujo energ tico positivo Gama de presiones Tama o de foco m n hasta m x fx 6dB fy 6dB fz 6dB Volumen de foco Frecuencia de pulsos Grados de intensidad Energia total E 5 mm Profundidad de penetraci n Peso Condiciones funcionamiento Condiciones almacenamiento y transporte EMS SA CH 1260 Nyon Suiza RICHARD WOLF GmbH 75438 Knittlingen Alemania Mango F10 G4 por Swiss PiezoClast Clase Pieza de aplicaci n tipo B IP 20 94 100 mm 0 03 a 0 4 mJ mm 11 5 a 82 2 MPa 1 2 a 2 8 mm 5 0 a 14 1 mm 58 mm 1a8Hz 20 niveles 9 54 mJ 5 a 40 mm approx 1 2 kg approx 2 7 Ibs 10 C a 35 C humedad relativa 30 a 75 presi n atmosf rica 700 hPa a 1060 hPa 5 C a 40 C humedad relativa 10 a 90 presi n atmosf rica 700 hPa a 1060 hPa 79 DATI TECNICI Descrizione del dispositivo Distributore Costruttore Modello Classificazione EN 60601 1 Classif
12. nergie de la pi ce main 52 Affichage de la version du logiciel Remarques de s curit Rangement du produit 202 Ee E anne 64 Garantie E 64 ACCOSSO MOS vis accion esa conca 64 Service EMS u a ne en 66 ue 68 Caract ristiques techniques Compatibilit electromagnetique Mesure prendre en cas d incident VT lte et TEE 48 Wartungsintervalle Sicherungen 0 2250 berpr fung des Handst cks 52 Anzeige der Software Version 56 Sicherheitshinweise in 58 Aufbewahren Des Produktes 62 Entsorgen des produktes 64 Garantie ncn rre enirn 64 Zubeh r 64 EMS service 66 Symbole 68 Technische daten nn een 78 Elektromagnetische vertr glichkeit 82 Fehlerbehebung un 86 Mantenimlento i 49 Intervalos de mantenimiento F sibl6S 3 fcire eoe Comprobar la energ a del mango 53 Indicar la versi n de software 57 Precauciones de seguridad 59 Conservaci n del producto 63 Eliminaci n del producto 65 En rrr n Accesorios Servicio t cnico EMS Simbolos e n o Especificaciones t cnicas 79 Com
13. sur une surface plane Placer la pi ce main dans le support de la pi ce a main de sorte qu elle repose bien sur le joint torique voir Fig 1 Bajonettring und Gelpad entfernen Handst ckhalter umdrehen und auf eine ebene Fl che stellen Das Handst ck so in den Handst ckhalter einsetzen dass es vollst ndig auf dem O Ring aufliegt Abb 1 Comprobar la energ a del mango Quitar el anillo de bayoneta y la almohadilla de gel Poner el soporte del mango cabeza abajo sobre una superficie plana Colocar el mango en el soporte de tal manera que descanse perfectamente en el anillo obturador Fig 1 Verifica dell energia del manipolo Togliete l anello a baionetta e il gelpad Rovesciare il supporto del manipolo e collocatelo su una superficie piana Collocate el manipolo nel relativo supporto in modo tale che poggi completamente sull O Ring Figura 1 Kontroll av applikatorns kapacitet Avl gsna gelplattans bajonettring Vand p applikatorhallaren och stall den p plant underlag S tt applikatorn i applikatorh llaren s att den vilar helt p O ringen Abb 1 53 Make sure that the 3 pins of the twist lock mechanism engage in the recesses of the handpiece holder Close the 3 quick action clamps Make sure you can feel and hear each quick action clamp engage in its self locking position Fill the test cylinder with tap water up to the fill mark M Fig 2 Set the shock wave
14. Aver as del aparato El aparato no funciona No onda de choque Posible causa No se ha conectado el interruptor de la red No est conectado el cable red Falta la alimentaci n el ctrica Fusible de red estropeado El interruptor de pedal no est enchufado averiado Eliminaci n Pulsar el interruptor de la red Conectar el cable red Comprobar la red de alimentaci n Cambiar el fusible de red Enchufar cambiar el interruptor de pedal 87 MISURE DA ADOTTARE IN CASO D INCIDENTE Messaggi d informazione elo di errore sul display Numero informazione Problema riscontrato Soluzione APPL Il manipolo non collegata o il collegamento a spina del manipolo stato interrotto durante Collegate el manipolo il rilascio di onde d urto Err 1 Presenza di errore nel generatore di alta tensione Informate l assistenza Err 2 Presenza di errore nel generatore di alta tensione Informate l assistenza Err 3 Presenza di errore nel generatore di alta tensione Informate l assistenza Err 4 Presenza di errore nel generatore di alta tensione o difetto del cavo di comunicazione HV Informate l assistenza della scheda d ingresso della unit di elaborazione al generatore di alta tensione Err 5 Il cavo di comunicazione HV della scheda d ingresso della unit di elaborazione al genera Informate l assistenza tore di alta tensione difettoso Err 6 Il modulo di memoria nell apparecchio difettoso Informate l assistenza Err 7 Il modulo di memoria nel
15. Connecting the foot pedal Connexion de la p dale Aufstecken des Fu schalters Connect the connector of the foot pedal to the Brancher le connecteur de la p dale dans la prise Stecker des Fu schalters in die Anschlu buchse socket and lock it pr vue a cet effet et visser einstecken und festschrauben Suministro del pedal Fornitura del pedale Ansluta en pedal o o Enchufar el enchufe del interruptor de pedal en el Infilate nella boccola la spina dell interruttore a S tt fotkontaktens anslutningskontakt i uttaget f r correspondiente conector y atornillarlo pedale e avvitate fotkontakten och skruva fast den Assembly instructions for the Swiss Instruction de montage pour le kit de Montageanweisung Befestigungssatz PiezoClast mounting kit option fixation Swiss PiezoClast option f r Swiss PiezoClast optional 1x 1x 1x o o el 2x D M5x10 Instrucciones de montaje por el juego de Istruzioni per il montaggio set di fissaggio Monteringsanvisning f r fastg ringssats fijaci n para el Swiss PiezoClast opci n per Swiss PiezoClast opzionale f r Swiss PiezoClast tillval OPERATING THE UNIT Checks A Run through the checks before and after each use Do not use the products if it is damaged or incom plete or has loose parts Return damaged products together with any loose parts for repair Do not attempt to do any re
16. F2 bet tigen das Blinken wird deaktiviert Handst ck hat Lebensdauer fast erreicht Reserve ca 50000 Sto wellen Das Blinken ist nicht mehr deaktivierbar Sto wellenanzeige End Handst ck hat Lebensdauer erreicht Sto wellenausl sung nicht mehr m glich Neues Handst ck anschlie en DN Falls die Fehler anhand dieser Tabelle nicht behoben werden k nnen bitte Service benachrichtigen oder das Ger t zur Reparatur einsenden Keine eigenen Reparaturversuche vornehmen Ger tefehler M gliche Ursache Ger t ohne Funktion Keine Sto welle 86 Netzschalter nicht eingeschaltet Netzkabel nicht angeschlossen Keine Netzspannung vorhanden Netzsicherung defekt Fu schalter nicht eingesteckt defekt Behebung Netzschalter bet tigen Netzkabel anschlie en Hausnetz berpr fen Netzsicherung auswechseln Fu schalter einstecken austauschen MEDIDAS A ADOPTAR EN CASO DE INCIDENTES Mensajes de error e informaciones en el visualizador No de informaci n Causa Eliminaci n APPL La mango no est conectada o la conexi n de la mango se desconecta durante el disparo de las Conectar la mango ondas de choque Err 1 Aver a en generador de alta tensi n Avisar al servicio t cnico Err2 Aver a en generador de alta tensi n Avisar al servicio t cnico Err 3 Aver a en generador de alta tensi n Avisar al servicio t cnico Err 4 Aver a en generador de alta tensi n o averiado el cable de comunicaci n de alta tensi n
17. apparaten st ngas av och stickkontakten dras ur eluttaget Apparaten kan g ras ren med en mjuk trasa som fuktats med ytdesinfektionsmedel eller alkohol Beakta desinfektionsmedeltillverkarens anvis ningar Se noga till att ingen fuktighet tr nger in i apparaten F r apparatens sk tsel f r inga puts skur eller l sningsmedel anv ndas terbearbetning av fotpedal A Fuktighet kan tr nga in i pedalen fotkon takten Risk f r elektriska st tar Pedalen fotkon takten eller anslutningskontakten f r inte s nkas ned i vatten eller reng ras under rinnande vatten Pedalen fotkontakten kan g ras ren med en mjuk trasa som fuktats med ytdesinfektionsmedel eller alkohol Beakta desinfektionsmedeltillverkarens anvis ningar 43 Reprocessing of the handpiece Retraitement de la pi ce main Aufbereitung des Handst cks A Danger of electric shock Make sure that no humidity enters the handpiece Do not immerse the handpiece or plug For reprocessing disconnect the handpiece from the device Make sure that no humidity enters inside the handpiece Do not use any cleaning or scouring agents or solvents on the handpiece 44 Danger d lectrocution S assurer que l humidit ne p n tre pas l int rieur de la pi ce main Ne pas immerger la pi ce main ni le connecteur D connecter la pi ce main avant le retrai tement Veiller ce qu aucune humidit ne puisse p n trer l int rieur
18. d urto Linterruttore a pedale non stato inserito difettoso Inserite sostituite l interruttore a pedale 88 FELS KNING Drift och felmeddelanden p displayen Meddelandenummer APPL Err 1 Err 2 Err 3 Err 4 Err5 Err 6 Err 7 Err 8 Err 9 Err 10 Err 11 Err 12 Tryckv gsdisplay blinkar Tryckv gsdisplay End Orsak Applikatorn ej ansluten eller applikatorns anslutning bruten under tryckv gs verf ring Fel i h gsp nningsgeneratorn Fel i h gsp nningsgeneratorn Fel i h gsp nningsgeneratorn Fel i h gsp nningsgeneratorn eller defekt kommunikationskabel h gsp nning fr n display E kort till h gsp nningsgenerator Kommunikationskabel h gsp nning fr n display E kort till h gsp nningsgeneratorn defekt Minnesmodul i apparaten defekt Minnesmodul i apparaten defekt Minnesmodul i apparaten defekt Minnesmodul i apparaten defekt Datafel i applikatorns minnesmodul Applikatorn ej programmerad Applikatorn inte godk nd f r utrustningen Applikatorns livsl ngd n stan uppn dd reserv ca 100 000 tryckv gor Applikatorns livsl ngd n stan uppn dd reserv ca 50 000 tryckv gor Applikatorns livsl ngd uppn dd tryckv gs verf ring inte l ngre m jlig Atgard Anslut applikatorn Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Kontakta Service Ansl
19. encender ste con el interruptor de la red El aparato realiza una autocomprobaci n Si no se indica ning n error el Swiss PiezoClast y el mango est n listos para el funcionamiento USO DELL UNIT Controlli A Eseguite i controlli necessari prima e dopo ogni impiego Non utilizzate pi prodotti danneggiati incompleti o che presentano parti staccate Inviate per la riparazione i prodotti danneggiati con le parti staccate Non cercate di eseguire da soli i lavori di riparazione Controllo visivo Verificate se l apparecchio e i relativi accessori risultano danneggiati se presentano parti staccate o mancanti Verificatene lo stato di pulizia e la completezza Verificate la presenza di eventuali danni sui cavi di collegamento di rete Le scritte e i contrassegni che sono necessari per un impiego sicuro e conforme alle disposizioni devono essere leggibili necessario rifare le scritte e i contrassegni mancanti o non pi leggibili che possono provocare errori nella manipolazione o nel riprocessamento dell apparecchio Verificate la presenza di eventuali danni sulla super ficie di contatto del manipolo Controllate la manipolo in base a quanto indicato nelle istruzioni d uso del relativa manipolo nel capitolo Manutenzione Controllo funzionale Collegate il manipolo all apparecchio e l apparecchio all interruttore di rete L apparecchio esegue un autotest Se non sono indicati errori lo Swiss PiezoC
20. las ondas de choque disparadas en cada tratamiento queda indicada tras pulsar la tecla Funci n F1 Para reponer a cero la indicaci n de la estad stica de ondas de choque pulse la tecla Reset La reposici n a cero de la indicaci n de la estad stica es autom tica despu s de desconectar y reconectar el equipo Estad stica de la suma total de ondas de choque disparadas con el mango Pulsar la tecla Funci n F2 y la tecla Intensidad de ondas de choque Se podr leer la suma de todas las ondas de choque disparadas por el mango conectada al aparato Estad stica de la suma total de ondas de choque disparadas con el aparato Pulsar la tecla Funci n F2 y la tecla Intensidad de ondas de choque v Se podr leer la suma de todas las ondas de choque disparadas por el aparato Ejemplo La indicaci n corresponde a 31476 ondas de choque Valutazione della terapia ad onde d urto Valore medio dell intensit di onda d urto Lintensita media di onda d urto per trattamento visua lizzata azionando il tasto funzione F1 Azionando il tasto Reset viene azzerata la statistica dell onda d urto Spegnendo e riaccendendo l apparecchio viene azzerata automaticamente la statistica dell onda d urto Statistica complessiva di onde d urto del manipolo Azionate il tasto funzione F2 e il tasto d intensit di onde d urto visualizzata la somma delle onde d urto emesse del manipolo collegata all
21. manipolo difettoso Informate l assistenza Err 8 Errore sulla scheda d ingresso della unit di elaborazione Informate l assistenza Err 9 Errore sulla scheda d ingresso della unit di elaborazione Informate l assistenza Err 10 Errore dati nel modulo di memoria nel manipolo Informate l assistenza Err 11 El manipolo non programmata Informate l assistenza Err 12 El manipolo non quella autorizzata per l apparecchio Collegate il manipolo autorizzata Il display delle onde d urto lampeggia La durata del manipolo quasi scaduta resta una scorta di circa 100000 onde d urto Azionate il tasto funzione F2 Il lampeggio disattivato La durata del manipolo quasi scaduta resta una scorta di circa 50000 onde d urto Non pi possibile disattivare il lampeggio Display delle onde d urto indica Fine La durata del manipolo scaduta non pi possibile rilasciare onde d urto Collegate una nuova manipolo Ah se non riuscite ad eliminare l errore seguendo quanto indicato nella presente tabella informate l assistenza o inviate l apparecchio per la riparazione Non cercate di eseguire da soli la riparazione Difetti dell apparecchio Possibile causa Soluzione Lapparecchio non funziona Linterruttore di rete non amp inserito Azionate l interruttore di rete Il cavo di rete non collegato Collegate il cavo di rete tensione di rete assente Verificate la rete locale Il fusibile di rete amp difettoso Sostituite il fusibile di rete Assenza di onde
22. medicamentos diluentes Embarazo Tejido pulmonar en la zona de las ondas de choque Ni os y ni as con ep fisis abierta Complicaciones Hasta la fecha no se ha observado ninguna complicaci n de gravedad Efectos secundarios Presencia de Hematomas locales petequias Irritaciones locales de la piel Edemas locales Terapia ad onde d urto extracorporea ESWT Indicazioni Tendinite calcifica della spalla Sindrome da conflitto impingement Epicondilite dell omero radiale ulnare Sindrome della punta rotulea Sindrome degli spigoli tibiali Achillodinia Fascite plantare con sperone calcaneare Pseudoartrosi Controindicazioni Infezioni locali Neoplasie locali Disordini della coagulazione necessario conoscere lo stato di coagulazione precedente Assunzione di farmaci anticoagulanti Gravidanza Presenza di tessuti polmonari nella zona da Sottoporre alla terapia Bambini con epifisi aperte Complicazioni Finora non sono state riscontrate complicazioni di tipo pi grave Effetti collaterali Riscontrato l insorgere di Ematomi locali petecchie e Irritazioni cutanee locali Edemi locali Utv rtes tryckv gsbehandling ESWT Indikationer e Kalcifierande tendinit i axeln Subakromialt sm rtsyndrom Epicondylitis humeri radialis ulnaris tennis golfarmb ge Patella apex syndrom Medialt tibiasyndrom benhinneinflammation Akillestendinit Plantar fas
23. que la versi n en alem n de este manual es la original de la que parten las traducciones En caso de discrepancias la versi n vinculante es la alemana Estaremos encantados de contestar a sus preguntas o escuchar sus sugerencias Por supuesto proporcionamos asistencia en caso de problemas t cnicos P ngase en contacto con su centro de reparaciones autorizado o distribuidor de EMS Le deseamos mucho xito EMS La versione tedesco di questo manuale amp la versione master da cui deriva la traduzione In caso di discrepanze fa fede il testo in tedesco Atutte le domande verr data risposta e i consigli sono ben accetti Ovviamente forniamo assistenza in caso di problemi tecnici Rivolgersi direttamente al centro di assistenza EMS autorizzato o al proprio rivenditore Auguriamo successo a tutti EMS Observera att den tysk versionen av handboken ar originalet som vriga spr k har versatts fran Vid eventuella avvikelser g ller den tyska texten Vi svarar g rna p fr gor och tar emot f rslag Vi ger sj lvklart support vid tekniska problem Kontakta ditt godk nda EMS reparationscenter eller din terf rs ljare Lycka till EMS CONTENTS Installation ae 2 Power connection 62 Connecting the foot pedal 4 Assembly instructions for the Swiss PiezoClast mounting kit option 6 Operating the unit 10 CMO NT 10 Preparing the handpie
24. x x ONOnRWN O x di dimm EMS fournit cet appareil avec diff rents accessoires La Packing list d taille exactement ce qui est inclus avec votre appareil BESTANDTEILE Ger t Anzeige StoBwellenintensit t Anzeige Sto wellenz hler und Informations und Fehlermeldungen Anzeige Stosswellenfrequenz Taste Stosswellenintensit t erh hen Taste Stosswellenintensit t verringern Taste Stosswellenfrequenz erh hen Taste Stosswellenfrequenz verringern Taste Stand By 10 Kontrollleuchte Stand By 11 Taste Vorwahl der Stosswellenanzahl 12 Taste Reset 13 Taste Funktion 1 14 Taste Funktion 2 15 Anschlussbuchse f r das Handst ck 16 Halter f r das Handst ck 17 Anschluss des Fusspedals 18 Fusspedal 19 Netzkabel 20 Hauptschalter 21 Netzeingang mit Sicherungshalter 22 Anschlussbuchse f r Fusspedal 23 Datenschnittstelle nur f r Service 24 Anschluss Potentialausgleich 25 L fter 26 Sicherungen 27 Gel Flasche 28 Gel Pad auswechselbar 29 Bajonettring f r Gelpad 30 Handst ck 31 Gel Pad Set 32 Befestigungssatz f r PiezoClast DolorClast 33 Pr fzylinder komplett 34 Halter f r das Handst ck Tischoberfl che OONONS ONA EMS bietet Ger te in unterschiedlichen Ausstattungsvarianten an F r die genaue Ausstattung Ihres Ger ts beachten Sie bitte die beiliegende Packliste COMPONENTES 1 Aparato 2 Indicaci n Intensidad de ondas de choque 3 Contador de ondas de ch
25. 6 3 6 4 6 6 10 3 6 Rekommendation f r Triggerpunktbehandling ESWT A Vid f r stort antal tryck v gor Potentiella v vnadsskador Applicera inte ett st rre antal tryckv gor per behandling n som anges i bruksanvisningen Indikationer Kalkaxel tendinosis calcarea Epicondylitis humeri radialis Epicondylitis humeri ulnaris Akillessena Akillestendinit Plantar fasciitis Patella apex syndrom Intensitet 6 10 3 6 3 6 4 6 6 10 3 6 Frecuencia de las ondas de choque Hz 4 6 4 6 4 4 6 4 6 4 6 Frequenza dell ondes d urto Hz 4 6 4 6 Triggerpunktbehandling frekvens Hz 4 6 4 6 4 4 6 4 6 4 6 N mero de las ondas de choque 2000 1500 2000 1500 2000 2000 2000 2000 2500 N mero dell ondes d urto 2000 1500 2000 1500 2000 2000 2000 2000 2500 St tar 2000 1500 2000 1500 2000 2000 2000 2000 2500 N mero de sessiones Wi CO Numero di trattamenti oO Antal sessioner oO CO 41 REPROCESSING Reprocessing of the device Mm Danger of electric shock Make sure that no humidity enters the device Before reprocessing switch off and disconnect the device from the power supply mains Clean the device with a soft cloth moistened with surface disinfectant or alcohol Follow the instructions from the manufacturer of the disinfectant Make sure that no humidity enters the device D
26. Anv nda nh t n css Kontrollet sa cocaina Seet F rberedelse av handstycke Anslutning av handstycksslangen Inst llning av tryckv gsintensitet N Inst llning av pulsfrekvens F rinst llning av antalet tryckv gor smska GE una onte e Pe tec 23 Behandling id Fotpedal o etes wel Utvardering av chockvagsterapin 29 FEUNKUONSPMINGIP rocosas ts 31 Behandlingsf rlopp med handstyck 33 Triggerpunktbehandling med tryckv gor Placeringsexempel 39 Rekommendation f r Triggerpunktbehandling ESWIT aus een 41 Ateranv ndas n 43 Aterbearbetning av apparaten 43 Aterbearbetning av fotpedal 43 Aterbearbetning av handstick 45 Maintenance seen ea ore rod tasas 48 Maintenance intervals 48 ZI 50 Checking the output power of the E 52 Display of software version 56 Safety pr cautions ss 58 Storing the product iere 62 Product disposal etes 64 Warranty lee 64 EMS SEVICE escaneada sacada 66 Symbols eet rt eere ruat 68 Technical data rrr tnr 76 Electromagnetic compatibility 82 Troublesliooting rs 84 EG criar toni tercia nan 48 Intervalles d entretien 48 F sibl6S oerte orte ertet rhet 50 V rification de l
27. I Die Garantie Ihres Produktes wird annul liert wenn Sie versuchen es zu ffnen ZUBEH R Zubeh r erhalten Sie bei EMS oder einem autori sierten H ndler Wenden Sie sich bitte direkt an Ihren zust ndigen Ansprechpartner ELIMINACI N DEL PRODUCTO El producto sus accesorios y el material de embalaje no contienen sustancias nocivas para el medio ambiente Si desea eliminar el producto definitivamente por favor respete las normas espec ficas vigentes en su pa s Los Residuos de Aparatos El ctricos y Electr nicos RAEE que pertenezcan a clientes que se encuentren en la Uni n Europea pueden enviarse a EMS para su reciclaje de conformidad con la normativa sobre RAEE El coste del reciclaje excluidos los gastos de env o lo cubre EMS GARANT A Los da os que pudieran resultar de la no observaci n de las instrucciones de empleo y del desgaste de las piezas no est n cubiertos por la garant a IS La garant a de su producto se cancelar si intentan abrirlo ACCESORIOS Los accesorios se encuentran disponibles direc tamente en EMS o a trav s de cualquiera de los distribuidores autorizados Por favor p ngase en contacto directamente con el servicio de atenci n al cliente SMALTIMENTO DEL PRODOTTO Il prodotto i suoi accessori e il suo imbal laggio non contengono sostanze nocive per l ambiente Se il prodotto dovr essere definitivamente smaltito vi preghiamo di attenervi alle direttive nazio
28. Kapitel Aufbereitung vor und Verpacken Sie dann das Produkt und alle Zubeh rteile in der Originalverpackung Beachten Sie bitte auch die Lager und Trans portbedingungen im Kapitel Technische Daten CONSERVACI N DEL PRODUCTO ES Le aconsejamos conserve el embalaje original hasta el momento de deshacerse de su producto De este modo podr utilizarlo en cualquier momento para almacenarlo temporal mente o transportarlo Utilice el recipiente de almacenamiento especial para el transporte y el almacenamiento de las almohadillas de gel Si piensa no utilizar su producto durante un per odo prolongado Siga el procedimiento descrito en el cap tulo Reprocesamiento Embale el producto y todos sus accesorios en el embalaje original Por favor observe tambi n las condiciones de almacenamiento y transporte descritas en el cap tulo Especificaciones t cnicas CONSERVAZIONE DEL PRODOTTO I Si consiglia di conservare l imballo originale fino allo smaltimento definitivo del vostro prodotto Utilizzare l imballo per la custodia ed il trasporto Per conservare e trasportare i gelpad utilizzare la scatola prevista a tal scopo In caso di inattivit prolungata Seguire le istruzioni nel capitolo Ritrat tamento Imballare il prodotto e tutti gli accessori nell imballo originale Vogliate anche tener conto delle informazioni sulle condizioni per lo stoccaggio ed il trasporto fornite nel capitolo Dat
29. OPERATION INSTRUCTIONS MODE D EMPLOI BEDIENUNGSANLEITUNG INSTRUCCIONES DE EMPLEO ISTRUZIONI PER L USO BRUKSANVISNING Caution Federal USA law restricts this device to sale by or on the order of a physician B ONLY Swiss PiezoClast ELECTRO MEDICAL SYSTEMS TECHNICAL MODIFICATIONS EMS reserves the right to modify the technique accessories operating instructions or contents of the set due to technical or scientific improvements MODIFICACIONES TECNICAS EMS se reserva el derecho de realizar modifica ciones en la t cnica los accesorios las instruc ciones de empleo asi como en el contenido del embalaje original siempre y cuando estas modificaciones representen un desarrollo t cnico o cient fico Fold out the cover pages to view technical drawings D plier les rabats pour visualiser les plans Spiegare i bordi piegati per leggere le istruzioni MODIFICATIONS TECHNIQUES EMS se r serve le droit d apporter la technique aux accessoires au mode d emploi et au contenu de l emballage d origine les modifications que la poursuite des d veloppements techniques et scientifiques peut induire MODIFICHE TECNICHE La EMS si riserva il diritto nell ambito delle innovazioni tecniche o scientifiche di apportare modifiche alla tecnica agli accessori alle istru zioni per l uso e al contenuto dell imballo originale Detailzeichnungen in den ausklappbaren Umschlagseiten Despliegue
30. RVICE Should your product need servicing and repairs please send it to your dealer or to an authorized EMS Repair Center EMS declines responsibility for the safety of the device and declares the warranty void if service or repair is carried out by an unauthorized third party or if non genuine spare parts are used It is best to ship the product in the original packaging It protects the product against damage during shipment Mm Please clean disinfect and sterilize the product and all accessories as described in the operating instructions before dispatching them When sending the product directly to an approved EMS repair center please include the name of your dealer This simplifies processing 66 SERVICE EMS Pour toute autre intervention de maintenance ou de r paration envoyer le produit votre distri buteur ou directement un centre de r paration agr EMS EMS d cline toute responsabilit envers la s curit de l appareil et d clare la garantie nulle si des entretiens ou des r parations sont effectu s par des tierces parties non autoris es ou si des pi ces non d origine taient utilis es Utiliser de pr f rence l emballage d origine pour l exp dition Le produit sera mieux prot g contre les incidents de transport Mm Nettoyer d sinfecter et st riliser le produit et l ensemble de ses accessoires conform ment au mode d emploi avant de les exp dier En cas d exp dition directe du p
31. Uttag 18 Fotpedal 19 N tkabel 20 Str mbrytare 21 Apparatingang f r n tkabel med s kringsh llare 22 Uttag f r fotpedal 23 Datagr nssnitt endast f r service 24 Anslutning f r potentialutj mning 25 Fl kt 26 S kringar 27 Gelflaska 28 Gelplatta utbytbar 29 Bajonettring f r gelplatta 30 Handstycke 31 Gelplattsats 32 Monteringsanvisning f r fastg ringssats f r PiezoClast DolorClast 33 Testcylinder f r handenhet 34 H llare f r handenhet av bordl gga EMS utrustar enheten med olika tillbeh r Packlistan visar exakt vad som medf ljer denna enhet DEAR CUSTOMERS Thank you for buying a new EMS product lt meets the highest quality and safety standards Intended use The EMS Swiss PiezoClast is intended to deliver focussed shock waves for the treatment of various indications on the musculoskeletal system The following indications are successfully treated with the EMS Swiss PiezoClast Trigger Point Shock Wave Therapy TPST Indications Chronic painful muscular hardening so called myofascial trigger points in the areas of the Upper extremities Shoulder girdle Hip area Lower extremities Contraindications Local infections Local tumor diseases Clotting disorders before use coagulation status analysis is necessary Use of haemo diluting medication Pregnancy Lung tissue in the shock wave entry window Children with open epiphyses Complications Serious c
32. ado o disolventes Reprocesamiento del pedal GS Existe el riesgo de que humedad penetre en el interruptor de pedal Peligro de choque el ctrico Abst ngase de sumergir el interruptor de pedal o el enchufe en agua o de limpiarlo a chorro de agua El interruptor de pedal se puede limpiar con un pa o suave humedecido con un desinfectante para superficies o alcohol Observe las indicaciones del productor del desin fectante RITRATTAMENTO Ritrattamento del apparecchio Mm L umidit pu penetrare nell apparecchio Rischio di scosse elettriche Prima di effettuare la verifica spegnete l apparecchio e staccatelo dalla rete di alimentazione possibile pulire l apparecchio con un panno morbido inumidito di disinfettante per superfici O alcool Seguite le indicazioni del fabbricante del disin fettante Fate in modo che l umidit non penetri nell apparecchio Per la manutenzione non utilizzate detergenti abrasivi o solventi Ritrattamento del pedale Mm L umidit pu penetrare nell interruttore del pedale Rischio di scosse elettriche Non immergete nell acqua il pedale e o la spina o non pulitelo con acqua corrente possibile pulire il pedale con un panno morbido inumidito di disinfettante per superfici o alcool Seguite le indicazioni del fabbricante del disin fettante ATERANVANDAS Aterbearbetning av apparaten A Fuktighet kan tr nga in i apparaten Risk f r elektriska st tar F re sk tsel ska
33. aktfl che des Handst cks auf Besch di gungen berpr fen Kontrolle des Handst cks entsprechend der Gebrauchsanweisung des Handst cks durch f hren im Kapitel Wartung Funktionskontrolle Handst ck am Ger t anschlie en und Ger t am Netzschalter einschalten Das Ger t f hrt einen Selbsttest durch Wenn keine Fehler angezeigt werden ist der Swiss PiezoClast und das angeschlossene Handst ck betriebsbereit UTILIZACI N DEL APARATO Controles A Los controles se han de llevar a cabo antes y despu s de cada aplicaci n No vuelva a utilizar los productos deteriorados incompletos o con piezas sueltas Env e los productos deteriorados junto con las piezas sueltas para reparaci n Abst ngase de repararlos Examen visual Examinar el aparato incluidos los accesorios en t rminos de da os piezas sueltas o faltantes higiene e integridad Comprobar los cables de conexi n a la red en t rminos de da os Los r tulos y las marcaciones necesarios para la aplicaci n segura y adecuada a su fin han de estar legibles Se han de restablecer todos aquellos r tulos y marcaciones faltantes e ilegibles que llevan a errores en el manejo y el retratamiento Comprobar la superficie de contacto del mango para ver si presenta da os Controlar el mango conforme a las instrucciones para el uso del correspondiente mango en el capitulo Mantenimiento Control de funcionamiento Conectar el mango al aparato y
34. als 10 cm hat das Handst ck noch gen gend Energie ES Betr gt die Spritzh he weniger als 10 cm Service benachrichtigen Tener cuidado en que los tres salientes del cierre de bayoneta se introduzcan en los huecos del soporte de la mango Cerrar los tres cierres r pidos Se ha de sentir y escuchar el chasquido de encla vamiento de cada uno de los cierres r pidos Introducir agua en el cilindro de prueba hasta la marca M Fig 2 Graduar la intensidad de las ondas de choque al grado 20 Poner la frecuencia de pulsos en 1 Disparar la onda de choque Si el surtidor alcanza una altura superior a 10 cm entonces la energ a de la mango es todav a suficiente IS Si la altura del surtidor es inferior a 10 cm avisar al servicio de asistencia t cnica Prestate attenzione ai 3 perni della chiusura a baionetta devono essere collocati nelle fresature del manipolo Chiudete i 3 dispositivi di serraggio rapido Fate attenzione a serrare con forza in modo visibile e udibile il punto di arresto di ciascun dispositivo di serraggio Riempite il cilindro di prova con acqua fino alla tacca di riempimento M figura 2 Regolate l intensit dell onda d urto sul livello 20 Regolate la frequenza d impulso su 1 Rilasciate l onda d urto Se l altezza d iniezione della fontana superiore ai 10 cm el manipolo dispone ancora di energia sufficiente I Se l altezza d iniezione inferiore a 10 cm contattare l
35. and 2 The higher the gel pad the lesser the penetration depth E see Figs 1 and 2 32 D roulement du traitement avec la pi ce main Positionner le patient sur une table de traitement ou une chaise de sorte qu il se trouve en position stable Veiller a ce que la zone a traiter soit ais ment accessible Marquer les limites de la zone de traitement sur la peau du patient par exemple avec un feutre Choisir le gel pad en fonction de la profondeur de p n tration voulue Le chiffre sur le gel pad A correspond la profondeur de p n tration E du foyer de traitement F en mm voir Figs 1 et 2 Pour une profondeur de p n tration E r duite il faudra choisir un gel pad plus haut voir Fig 1 et 2 Behandlungsablauf mit dem Handst ck Patient auf einer Behandlungsliege oder einem Stuhl lagern und in eine stabile Lage bringen Dabei darauf achten dass das Therapiefeld leicht zug nglich ist Landmarke Grenzbereiche des Behandlungsfelds auf der Hautoberfl che einzeichnen z B mit einem Filzstift Gelpad entsprechend der vorbestimmten Eindring tiefe ausw hlen Die Zahl auf dem Gelpad A entspricht der Eindring tiefe E des Therapiefokus F in mm siehe Abb 1 und 2 Je h her das Gelpad desto geringer die Eindring tiefe E siehe Abb 1 und 2 Fases del tratamiento con el mango Colocar al paciente en posici n estable sobre una litera de tratamiento o en una silla cuidando de
36. ano parti staccate Inviate per la riparazione i prodotti danneggiati con le parti staccate Non cercate di eseguire da soli i lavori di riparazione N Fate attenzione alla marcatura sulla spina e a quella sulla boccola Devono coincidere N Infilate o estraete la spina del manipolo esclusivamente quando l apparecchio amp scollegato Anslutning av handstycksslangen A Anv nd inte l ngre produkt som r skadad saknar delar eller har l sa delar Skicka skadad produkt tillsammans med l sa delar f r reparation F reta inga egna reparationsf rs k Se till att markeringarna p anslutningskon takten och uttaget st mmer verens Applikatorns anslutningskontakt f r bara s ttas i och dras ur apparaten n r denna r avst ngd Selecting shock wave intensity R glage de l intensit des ondes de choc Sto wellenintensit t einstellen Frequency 1 Shock wave intensity 1 to 20 Use the shock wave intensity v reduce and shock wave intensity increase buttons to set the shock wave intensity Sublevels of intensity 1 The intensity adaptation levels 0 0 to 0 9 allow settings for pain sensitive or otherwise sensitive application areas 2 Activating the sublevels Press and hold the shock wave intensity v reduce button for approx 2 seconds until shock wave intensity 0 0 is displayed The shock wave intensity can be adjusted between 0 0 and 0 9 3 Deactivati
37. apia de puntos gatillo por ondas de choque TPST Indicaciones Endurecimiento muscular cr nico doloroso los llamados puntos gatillo miofasciales en las regiones de Extremidades superiores Cintura escapular Regi n de la cadera Extremidades inferiores Contraindicaciones Infecciones locales Tumores locales Trastornos de coagulaci n previamente se tienen que verificar los factores relativos a la coagulaci n Toma de medicamentos diluentes Embarazo Tejido pulmonar en la zona de las ondas de choque e Ni os y ni as con ep fisis abierta Complicaciones No se ha observado ninguna complicaci n de gravedad Efectos secundarios Presencia de Hematomas locales petequias e Irritaciones locales de la piel Edemas locales GENTILE CLIENTE Ci congratuliamo con voi per l acquisto di questo nuovo prodotto EMS Esso soddisfa le pi alte esigenze di qualit e di sicurezza Uso previsto Lo Swiss PiezoClast EMS destinato a produrre delle onde d urto focalizzate per il trattamento di differenti indicazioni dell apparato locomotore Lo Swiss PiezoClast EMS sono state trattate con successo le seguenti indicazioni Terapia ad onde d urto focalizzate su trigger point TPST Indicazioni Forme croniche di contrazioni muscolari dolorose altri punti trigger miofasciali nelle zone Estremit superiori Cintura scapolare Regione dell anca Estremit inferiori Controindicazioni e Infezio
38. apparecchio Statistica complessiva di onde d urto dell apparecchio Azionate il tasto funzione F2 e il tasto d intensit di onde d urto v visualizzata la somma delle onde d urto emesse dell apparecchio Esempio Il valore indicato sul display corrisponde a 31476 onde d urto Utv rdering av chockv gsterapin Medelv rde tryckv gsintensitet Genomsnittlig tryckv gsintensitet per behandling visas genom att trycka p knappen Funktion F1 Visningen av tryckv gsstatistiken nollst lls genom att trycka p knappen Reset Om apparaten st ngs av och ter sl s p nollst lls automatiskt tryckv gsstatistiken Total tryckv gsstatistik f r applikatorn Genom att trycka p knappen Funktion F2 och knappen tryckv gsintensitet visas det totala antalet tryckv gor som avgetts av den applikator som r ansluten till apparaten Total tryckv gsstatistik f r apparaten Genom att trycka p knappen Funktion F2 och knappen v tryckv gsintensitet visas det totala antal tryckv gor som apparaten har avgett Exempel Displayen visar 31476 tryckv gor 29 Operating principle of the PiezoClast Principe de fonctionnement de la pi ce Funktionsprinzip des PiezoClast handpiece a main Handst cks The shape of the handpiece focuses the shock La forme de la piece main focalise les ondes de Bedingt durch die Bauform des Handst cks waves S generated by the Piezo elements pression S des l ments pi zo
39. applicata del tipo B IP 20 94 100 mm 0 03 a 0 4 mJ mm Tra 11 5 e 82 2 MPa Tra 1 2 e 2 8 mm Tra 5 0 e 14 1 mm 58 mm Tra 1e 8 Hz 20 livelli 9 54 mJ Tra 5 e 40 mm ca 1 2 kg ca 2 7lbs Tra 10 C e 35 C umidit relativa tra 30 e 75 pressione dell aria tra 700 hPa e 1060 hPa Tra 5 C e 40 C umidit relativa tra 10 e 75 pressione dell aria tra 700 hPa e 1060 hPa TEKNISKA DATA Beskrivning av enheten Distribut r Tillverkare Modell Klassificering EN 60601 1 Klassificering 93 42 EG N tsp nning N tfrekvens Str mf rbrukning Bullerniv S kringar Driftl ge Vikt M ttIxbxh Anv ndningsf rh llanden F rvaring och transportf rh llanden EMS SA CH 1260 Nyon Schweiz RICHARD WOLF GmbH 75438 Knittlingen Tyskland Swiss PiezoClast Klass Till mpad del Typ B IP 20 apparat IP X8 elektrisk fotpedal Mode kontinuerlig drift Klass IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A T3 15L Flerpulsl ge Pulsfrekvens 1 20 Hz ca 14 5 kg 395 mm x 400 mm x 170 mm 10 35 C 30 75 rel luftfuktighet Lufttryck 700 1 060 hPa 5 40 C 10 90 rel luftfuktighet Lufttryck 700 1 060 hPa Beskrivning av handstycke Distribut r Tillverkare Modell Klassificering EN 60601 1 ppningsvinkel ppningsdiameter Energifl dest thet positiv Tryckkapacitet Fokusstorlek min till max fx 6dB fy 6dB fz 6dB Fokusvolym Pulsfrekvens Inten
40. asonido validados para el empleo en pacientes Si raggiunge la profondit massima possibile di penetrazione di 40 mm ca se amp utilizzato il gelpad pi basso senza denominazione Applicate in modo uniforme il gel per ultrasuoni sul gelpad e sul paziente evitando la formazione di bolle d aria Collocate il manipolo in posizione verticale sul punto interessato La punta di centraggio B e le linee guida C servono per orientare e allineare l apparecchio quando viene collocato sulla zona da trattare Dopo ogni impiego limpiare il manipolo secondo quanto indicato nel capitolo Riproces samento Utilizzate esclusivamente i gel per ultrasuoni autorizzati per l impiego sui pazienti Det maximala penetreringsdjupet p ca 40 mm uppn s n r den l gsta gelplattan utan beteckning anv nds Applicera j mnt och utan luftbl sor ultraljudgelet p gelplattan och patienten Placera applikatorn vinkelr tt mot huden p behandlingsst llet Centreringspunkten B och syftlinjerna C hj lper till att placera och rikta in applikatorn p behand lingsst llet Reng r applikatorn efter varje anv ndning enligt anvisningarna under avsnitt teranv ndas Anv nd endast ultraljudgel till tna f r patientbruk Beakta geltillverkarens anvisningar 35 TRIGGER POINT SHOCK WAVE THERAPY TPST Indications Trigger Point Shock wave Therapy TPST Chronical painful muscular hardening so called myofascial trigg
41. assistenza Var noga med att bajonettanslutningens tre pinnar s tts i applikatorh llarens fr sta sp r St ng de tre snabbutl sningssp nnena Kontrollera att snabbutl sningssp nnena h rbart och m rkbart l ser ordentligt fast i sina l spunkter Fyll testcylindern till p fyllningsm rket M Abb 2 St ll in tryckv gsintensiteten p steg 20 St ll in pulsfrekvens 1 Utl s tryckv gor Om font nens spruth jd uppgar till mer n 10 cm har applikatorn fortfarande tillr cklig kapacitet Kontakta service om spruth jden uppg r till mindre n 10 cm 55 Display of software version Affichage de la version du logiciel Anzeige der Software Version SWISS PIEZOCLAST Preselection Reset 00 00 OO OO Push the F2 and v buttons simultaneously Appuyer simultan ment sur la touche F2 et la Die Tasten F2 und v gleichzeitig dr cken touche v 56 Indicar la versi n de software Pulsar al mismo tiempo las teclas F2 y v Display della versione software Premete contemporaneamente i tasti F2 e di v Visning av programvaruversion Tryck samtidigt in knapparna F2 och v 57 SAFETY PRECAUTIONS EMS and the distributor of this product accept no liability for direct or consequential injury or damage resulting from improper use arising in particular through non observance of the operating instruc tions or improper preparation and mainte
42. b genommen werden ES Bestimmte Typen mobiler Funkkommuni kationsger te k nnen das Funktionieren dieses Produkts beeintr chtigen Die empfohlenen r umlichen Entfernungen m ssen gem ss der Anweisung Elektromagnetische Vertr glichkeit eingehalten werden N Dieses Produkt darf nicht in der N he eines anderen Ger ts verwendet oder darauf gestapelt werden ausser auf einem EMS Swiss DolorClast Wird dieses Produkt auf einem EMS Swiss Dolor Clast betrieben darf jeweils nur eines der beiden Ger te eingeschaltet sein In jedem Fall muss die Funktion des Ger tes in dieser Konfiguration vor Benutzung gepr ft werden N Der Gebrauch anderer Zubeh rteile oder Kabel die nicht empfohlen oder als Ersatzteile geliefert werden kann zu verst rkten Emissionen oder verringerter St rfestigkeit dieses Produktes f hren COMPATIBILIDAD ELECTROMAGNETICA IS Este producto necesita precauciones especiales referentes a la compatibilidad electro magn tica y necesita ser instalado y puesto en servicio seg n la gu a Compatibilidad electro magn tica Es Determinados tipos de equipos de teleco municaciones m viles pueden interferir poten cialmente con este producto Se deben tener en cuenta las distancias de separaci n recomen dadas en la gu a Compatibilidad electromag n tica A No se debe utilizar este producto cerca o apilado sobre un otro aparato la nica confi guraci n posible es el apilamiento con el Swiss DolorC
43. cata del tipo BF Till mpad del typ BF Tensi n alterna Tensione alternata V xelsp nning Transferencia de datos Trasferimento dati Data verf ring Conexi n para el pedal de mando Connessione per il pedale Anslutning av fotpedal Fusible Fusibile S kring Tecla Espera Funcionamiento con diodo luminoso Tasto Standby ON con LED Vilol ge P med kontrollampa SYMBOLER Apparat 69 Preselection Reset Intensity Impulse Count Frequency A Vv 70 Shock wave preselection Pr s lection des ondes de choc Sto wellenvorwahl Reset button Touche de remise z ro Taste Reset Shock wave intensity Intensit de l onde de choc Sto wellenintensit t Number of shock waves Compteur d ondes de choc Sto wellenanzahl Shock wave frequency Augmenter la valeur de r glage Sto wellenfrequenz Increase value Augmenter la valeur Wert erh hen Decrease value Baisser la valeur Wert verringern Handpiece connection Connexion pour la piece a main Anschluss f r das Handst ck Preselection Reset Intensity Impulse Count Frequency A D Preselecci n de ondas de choque Preselezione onda d urto Tryckv gsf rval Tecla Reset reposici n Tasto Reset terst llningsknapp Intensidad de ondas de choque Intensita dell onda d urto Tryckv gsintensitet N mero de ondas de choque Conteggio delle onde d urto Impulsr knare Frecuencia de pulsos Freq
44. ce 12 Connecting the handpiece 16 Selecting shock wave intensity 18 Setting the shock wave frequency 20 Presetting the total number of shock waves 10 e EE 22 Treatment sequence 24 Foot pedal 1 notet 26 Evaluation of shock wave therapy 28 Operating principle of the PiezoClast handpiece tace aee os 30 Treatment sequence using the handpiece 32 Trigger point shock wave therapy TPST 37 Indicationsi canne 37 Orthopedics ESWT susmmsnnssessssseressnnesrorrnnnrr na 38 Positioning examples 38 Recommendation for shock waves therapy IS UNK ener eenen ee 40 Reprocessing 42 Reprocessing of the device 42 Reprocessing of the foot pedal 42 Reprocessing of the handpiece 44 SOMMAIRE Installations aaa 2 Connexion lectrique Connexion de la p dale Instruction de montage pour le kit de fixation Swiss PiezoClast option 6 Utilisation de l appareil 10 Controles acicate metres 10 Pr paration de la pi ce main 12 Connexion de la pi ce main 16 Reglage de l intensit des ondes de choc 18 R glage de la fr quence d impulsions 20 Preselection du nombre total d ondes de choc appliquer D roulement du traitement P dale de commande
45. che an Qualit t und Sicherheit Zweckbestimmung Der EMS Swiss PiezoClast wurde zur Therapie verschiedener Indikationen des St tz und Bewegungsapparates mit fokussierten Stoss wellen entwickelt Folgende Indikationen werden mit dem EMS Swiss PiezoClast erfolgreich behandelt Anwendungsgebiet Trigger Punkt Sto wellen Therapie TPST Indikationen Chronische schmerzhafte muskul re Verspan nungen sogenannte myofasziale Triggerpunkte in den Bereichen Obere Extremit ten Schulterg rtel H ftregion Untere Extremit ten Kontraindikationen Lokale Infektionen Lokale Tumorleiden Gerinnungsst rungen vorherige Gerinnungs statusabkl rung notwendig Einnahme von blutverd nnenden Medika menten Schwangerschaft Lungengewebe im Sto wellenbereich Kinder mit offenen Wachstumsfugen Komplikationen Komplikationen ernst zu nehmender Art sind bislang nicht beobachtet worden Nebenwirkungen Auftreten von Lokalen Hamatomen Petechien Lokalen Hautreizungen Lokalen Odemen ESTIMADOS CLIENTES Les felicitamos por la adquisici n de su nuevo producto EMS El cual satisface las exigencias m s altas en lo que a calidad y seguridad se refiere Uso previsto El Swiss PiezoClast est destinado a generar ondas de choque focalizadas para el tratamiento de diferentes indicaciones en el aparato muscu loesquel tico Tratan exitosamente las siguientes afecciones con el Swiss PiezoClast EMS Ter
46. cit Pseudartros Kontraindikationer Lokala infektioner Lokala tum rer Koagulationsst rningar f reg ende koagula tionsstatusunders kning n dv ndig Medicinering med blodf rtunningsmedel Graviditet Lungv vnad i tryckv gsomr det Barn med ppna epifyser Komplikationer Komplikationer av allvarligt tilltagande art har hittills inte Konstaterats Biverkningar Kan upptr da Lokala hematomer petekier Lokala hudirritationer Lokala dem ABOUT THIS MANUAL These operating instructions are to ensure the correct installation and use of this product Please read these operating instructions carefully as they explain all the most important details and procedures Please pay special attention to the safety precautions Always keep this manual close at hand Follow instructions for use this product needs special precautions regarding electromag netic compatibility and needs to be installed and put into service according to the Electromagnetic compatibility manual To prevent possible patient or user injury or damage to the PiezoClast please note the corre sponding directives Danger Risk of patient or user injury Caution Risk of damage to the device or environmental harm Please note Useful additional information and hints Prohibited Authorized AXE PB A PROPOS DE CE MANUEL Ce mode d emploi est destin l installation et l utilisation correcte de ce produit Veuillez li
47. ctionner simultan ment les touches Intensity v et pour remettre l intensit O Si une des touches reste enfonc e l intensit de l onde de choc sera automatiquement report e la valeur minimale respectivement maximale Fr quence R gler pour les impulsions individuelles la fr quence d impulsions O R gler pour les impulsions continues la valeur de fr quence respective Il est recommand de commencer par une intensit basse des ondes de choc et d augmenter l intensit doucement en fonction de l indication Lorsqu il s agit d une zone plus grande traiter il peut s av rer avantageux de positionner le foyer sur diff rentes r gions Behandlungsablauf Sto wellentherapie A Sto wellen nur ausl sen wenn der Fokus im Zielgebiet ist sonst M glichkeit erh hten Auftretens von Nebenwirkungen Sto wellen applikationen d rfen nur erfolgen wenn eine eindeutige Identifikation des Zielgebietes und eine Beurteilung m glicher Beeintr chtigungen der durch den Verlauf der Sto wellen beaufschlagten Regionen erfolgt ist Intensit t Durch gleichzeitiges Bet tigen der beiden Tasten Intensity v und wird die Intensit t auf Null zur ckgestellt Bleibt eine der Tasten gedr ckt wird die Sto wellenintensit t automatisch bis zum minimalen bzw maximalen Wert verstellt Frequenz F r einzelne Stosswellen die Stosswellenfrequenz 0 einstellen F r kontinuierliche Stosswellenabgabe die e
48. d mit Oberfl chendesinfektionsmittel desinfizieren F r die Gelpads d rfen nur geeignete und zugelassene Desinfektionsmittel verwendet werden Die Angaben des Desinfektionsmittelherstellers beachten Hersteller Handelsname Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Extra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid Quitar la almohadilla de gel del mango Lavar la superficie de contacto del mango la almohadilla de gel y el anillo de bayoneta con agua tibia de la tuber a m x 30 C a continuaci n frotar con un pa o desechable y desinfectar con un desinfectante para superficies Para la desinfecci n de las almohadillas de gel se deben utilizar nicamente desinfectantes apropiados y validados para este fin Observe las indicaciones del productor del desin fectante Fabricante Marca comercial Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Extra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid Togliete il gelpad del manipolo Pulite la superficie di contatto del manipolo il gelpad e l anello a baionetta sotto dell acqua tiepida corrente max 30 C poi asciugate con un panno monouso e disinfettate con un disinfettante per superfici Peri gelpad potete utilizzare solo detergenti adatti e autorizzati Seguite le indicazioni del fabbricante del disin fettante Fabbricante Nome commerciale Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Ex
49. d onde d urto a Rilasciate l onda d urto solo se il fuoco si trova nella zona bersaglio Diversamente amp possibile una forte insorgenza di effetti collaterali Le onde d urto devono essere applicate solo se stata chiaramente individuata la zona bersaglio da trattare e dopo aver valutato i possibili danni alle regioni interessate dal percorso dell onda d urto Intensit Azionando contemporaneamente entrambi i tasti i it v vi zz il v dell intensit e viene azzerato il valore dell intensit Seuno dei tasti rimane premuto il valore d intensit dell onda d urto regolato automaticamente fino al valore minimo e o massimo Frequenza Per impulsi singoli impostate la frequenza d impulso 0 Per impulsi continui impostate la relativa frequenza d impulso Iniziate con un intensit di onde d urto pi bassa e in seguito aumentate lentamente l intensit in base all indicazione Nel trattamento di zone terapiche pi grandi preferibile posizionare il fuoco in punti diversi di seguito Behandling Chockv gsterapi A Utl s chockv gen endast om fokus r inst llt p m lomr det Annars kar mojligheten att biverkningar kan upptr da Chockv gsingrepp f r bara g ras om m lomr det entydigt fastst llts och en bed mning av m jliga biverkningar i de regioner chockv gen m ste passera gjorts Intensitet Genom att samtidigt trycka p de b da knapparna v och f r intensitet nollst lls int
50. d urto Tasto Diminuire intensit onde d urto Tasto Aumentare frequenza impulso Tasto Diminuire frequenza impulso Tasto Stand By Spia di controllo Stand By Tasto preselezione del numero onde d urto Tasto Reset Tasto Funzione 1 Tasto Funzione 2 Boccola di collegamento per manipolo Supporto manipolo Connettore Pedale di comando Cavo di alimentazione Interruttore di alimentazione Interruttore di rete con portafusibile Boccola di collegamento per il pedale di comando Interfaccia dati solo per assistenza Collegamento compensazione di potenziale Ventola Fusibili Bottiglia di gel Gelpad sostituibile Anello baionetta per gelpad Manipolo Set di gelpad Set di fissaggio per PiezoClast DolorClast Cilindro di prova completo Supporto manipolo di tavola EMS fornisce questa unit dotata di vari accessori Nella distinta di spedizione sono elencati esattamente tutti gli articoli contenuti nell unit KOMPONENTER 1 Apparat 2 Indikator tryckv gsintensitet 3 Indikator antal tryckv gsimpulser samt drifts och felmeddelanden 4 Indikator pulsfrekvens 5 Knapp Oka tryckv gsintensitet 6 Knapp Minska tryckv gsintensitet 7 Knapp Oka pulsfrekvens 8 Knapp Minska pulsfrekvens 9 Knapp f r v ntel ge 10 Kontrollindikator vantelage 11 Forvalsknapp f r antal tryckvagsimpulser 12 Aterstallningsknapp 13 Knapp Funktion 1 14 Knapp Funktion 2 15 Uttag for handenhet 16 H llare f r handenhet 17
51. da p enheten eller milj n ES Observera Ytterligare praktisk information och tips gt lt F rbjudet va Till tet Note that the German version of this manual is the master from which translations derive In case of any discrepancy the binding version is the German text We would be pleased to answer your questions or listen to your suggestions We do of course provide support in case of technical problems Please call directly your approved EMS repair center or your dealer We wish you lots of success EMS Les traductions dans ce manuel sont bas es sur sa version allemande Ainsi le texte en allemand fera r f rence en cas de divergence Nous sommes a votre enti re disposition pour r pondre a vos questions et nous sommes l coute de vos ventuelles suggestions Naturellement nous vous proposons un soutien technique en cas de probl mes Veuillez contacter votre centre de r paration agr e EMS ou votre distributeur Avec nos meilleurs v ux de succ s EMS Es wird darauf hingewiesen dass das deutsche Original dieser Bedienungsanleitung als Vorlage f r alle bersetzungen gilt Bei eventuellen Abwei chungen ist der deutsche Text bindend Wir stehen Ihnen gerne f r Fragen zur Verf gung Bei Problemen bieten wir Ihnen selbstverst ndlich technische Unterst tzung an Wenden Sie sich bitte an ein EMS genehmigtes Reparaturzentrum oder Ihren H ndler Wir w nschen Ihnen viel Erfolg EMS N tese
52. de la pi ce main N utiliser pour l entretien de la pi ce main ni d tergents ni produits r curer ni solvants A Feuchtigkeit kann in das Handst ck eindringen Gefahr eines elektrischem Schlags Das Handst ck bzw den Stecker nicht in Wasser eintauchen Das Handst ck zur Aufbereitung vom Ger t trennen Darauf achten dass keine Feuchtigkeit in das Handst ck eindringt F r die Pflege d rfen keine Putz Scheuer oder L sungsmittel einge setzt werden Reprocesamiento del mango A Riesgo de penetraci n de humedad en el mango Peligro de choque el ctrico No sumergir la mango o el enchufe Antes del reprocesamiento separar el mango del aparato Tener cuidado en que no penetre humedad alguna en el mango Para los cuidados no se deben utilizar detergentes agentes de restregado o disolventes Ritrattamento del manipolo A L umidit pu penetrare nelle manipolo Rischio di scosse elettriche Non immergete il manipolo e la spina Staccate il manipolo dall apparecchio per poterlo ritrattar Fate in modo che l umidit non penetri nelle manipolo Per la manutenzione non utilizzate detergenti abrasivi o solventi terbearbetning av handstick A Fuktighet kan tr nga in i pedalen fotkon takten Risk f r elektriska st tar Pedalen fotkon takten eller anslutningskontakten f r inte s nkas ned i vatten eller reng ras under rinnande vatten Pedalen fotkontakten kan g ras ren med en mjuk trasa s
53. e pi importanti Porre un attenzione speciale alle precauzioni di sicurezza Tenere questo documento sempre a portata di mano Riferirsi a le istruzioni per l uso questo prodotto richiede precauzioni speciali in relazione alla compatibilit elettromagnetica e va installato e messo in servizio in conformit al manuale Electromagnetic compatibility Per impedire possibili lesioni al paziente o all utiliz zatore o danni al PiezoClast attenersi alle relative direttive A Pericolo Rischio di lesioni al paziente o all utilizzatore Attenzione Rischio di danni al dispositivo o all ambiente Fare riferimento a ulteriori informazioni e consigli A ES gt lt Vietato DS a Autorizzato OM DENNA HANDBOK Syftet med denna bruksanvisning r att s kerst lla att produkten installeras och anv nds p r tt s tt Las bruksanvisningen noga har beskrivs alla viktiga detaljer och procedurer Var s rskilt uppm rksam p s kerhetsf reskrifterna Ha alltid detta dokument n ra till hands Se till anvisningshandboken denna produkt kr ver s rskilda f rsiktighets tg rder vad g ller elektromagnetisk kompatibilitet och m ste installeras och drifts ttas i enlighet med anvisningarna i handboken Electromagnetic compatibility F r att f rhindra patientskador eller skador p PiezoClast ska f ljande varningar observeras A Fara Risk f r skada p patient eller anv ndare A Varning Risk f r ska
54. e las instrucciones de empleo o por una preparaci n y un mantenimiento incorrectos Mm Contraindicaci n las vibraciones ultra s nicas pueden hacer que los marcapasos y desfibriladores cardiacos no funcionen correc tamente Por tanto se recomienda no tratar con este producto a pacientes portadores de un marcapasos o un desfibrilador Mm En pacientes que padecen enfermedades infecciosas se han de llevar a cabo las siguientes medidas Antes del tratamiento recubrir las heridas abiertas de tal manera que no salga l quido corporal alguno Despu s de la terapia desinfectar el aparato Observar las indicaciones del productor del desinfectante No disparar ondas de choque sobre rganos que contienen aire p ej pulm n intestino Tener en cuenta el sentido de entrada del mango y o posicionar al paciente correspondientemente Las ondas de choque pueden provocar acciones card acas no deseadas Mm Utilizar nicamente para su finalidad prevista Antes de utilizar este producto por primera vez lea con atenci n estas instrucciones de empleo hasta su completa comprensi n V lido igualmente para todos los productos que utilice en combinaci n con este aparato La no observancia de estas instrucciones de empleo puede tener como consecuencia lesiones o desperfectos de los productos OSSERVAZIONI SULLA SICUREZZA EMS e il distributore di questo prodotto declinano ogni responsabilit per danni diretti o indiretti che pos
55. ell apparecchio ES Nel caso in cui le disposizioni di legge del Paese in cui l apparecchio amp utilizzato prescrivano intervalli piu brevi dovranno essere osservati questi ultimi ES Per soddisfare gli standard IEC 60601 1 sui test tecnici e di sicurezza cosi come sugli intervalli di manutenzione l utilizzatore deve seguire le leggi e regolamentazioni locali nel paese in cui il dispositivo in funzionamento Tale manutenzione pu essere realizzata da EMS o da un centro di riparazioni autorizzato S kringar A Anv nd endast den typ av s kring som anges p apparatens baksida ES Om lagbest mmelserna ditt land kr ver kortare intervaller m ste dessa f ljas ES F r att f lja standarden IEC 60601 1 om tekniska tester s kerhetstester och underh lls intervall m ste anv ndaren f lja lokala lagar och best mmelser i det land d r apparaten anv nds Detta underh ll kan utf ras av EMS eller av ett auktoriserat servicest lle 51 Checking the output power of the handpiece Fig 1 V rification de l nergie de la piece main Fig 2 berpr fung des Handstiicks Remove the twist lock ring and the gel pad Turn the handpiece holder upside down and place iton an even surface Place the handpiece into the handpiece holder in such a way that it rests fully against the O ring Fig 1 52 Retirer la bague baionnette et le gel pad Retourner le support de la pi ce main et le poser
56. elle est d fectueuse Brancher remplacer la p dale Actionner l interrupteur principal Brancher le cordon d alimentation V rifier le secteur de l immeuble 85 FEHLERBEHEBUNG Fehlermeldungen auf der Anzeige Informations nummer Ursache Behebung APPL Handst ck ist nicht angeschlossen oder Steckverbindung des Handst cks wird w hrend der Handst ck anschlie en Sto wellenausl sung unterbrochen Err 1 Fehler im Hochspannungsgenerator Service benachrichtigen Err 2 Fehler im Hochspannungsgenerator Service benachrichtigen Err 3 Fehler im Hochspannungsgenerator Service benachrichtigen Err 4 Fehler im Hochspannungsgenerator oder HV Kommunikationskabel von der Processor E Service benachrichtigen Karte zum Hochspannungsgenerator defekt Err 5 HV Kommunikationskabel von der Processor E Karte zum Hochspannungsgenerator defekt Service benachrichtigen Err 6 Speichermodul im Ger t defekt Service benachrichtigen Err 7 Speichermodul im Handst ck defekt Service benachrichtigen Err 8 Fehler auf Processor E Karte Service benachrichtigen Err 9 Fehler auf Processor E Karte Service benachrichtigen Err 10 Datenfehler im Speichermodul des Handst cks Service benachrichtigen Err 11 Handst ck ist nicht programmiert Service benachrichtigen Err 12 Handst ck ist f r das Ger t nicht freigegeben Freigegebene Therapiequelle anschlie en Sto wellenanzeige blinkt Handst ck hat Lebensdauer fast erreicht Reserve ca 100000 StoRwellen Funktionstaste
57. eller genom att p nytt trampa p fotpedal aktiveras ter chockv gsutl sningen 27 Evaluation of shock wave therapy Mean shock wave intensity The mean average shock wave intensity output for each treatment is displayed when you press the F1 function button The shock wave statistics display is reset to zero by pressing the Reset button The shock wave statistics display is reset to zero automatically after switching the device off and on again Overall shock wave statistics of the handpiece Press the F2 function and the shock wave intensity A buttons The display shows the total number of shock waves generated by the handpiece connected to the device Overall shock wave statistics of the device Press the F2 function and the shock wave intensity v buttons The display shows the total number of shock waves generated by the device Example This display represents 31476 shock waves 28 Evaluation du traitement par ondes de choc Valeur moyenne de l intensit des ondes de choc La valeur moyenne de l intensit de l onde de choc mise par traitement est affich e sur actionnement de la touche de Fonction F1 L affichage de la statistique des ondes de choc est remis 0 par appui sur la touche Reset L affichage de la statistique des ondes de choc est automatiquement remis 0 par la mise hors tension et la remise en service de l appareil Statistique du to
58. endet ES Automatischer Sto wellenstop nach Erreichen von 4000 Sto wellen stoppt die Sto wellenausl sung automatisch Durch Bet tigen der Taste Funktion F2 oder durch erneutes Bet tigen des Fu pedals wird die Sto wellenausl sung wieder aktiviert Pedal Disparar la onda de choque pulsando el interruptor de pedal El equipo deja de disparar ondas de choque tan pronto como se levante el pie del pedal ES Parada autom tica del disparo de ondas de choque una vez disparadas 4000 ondas de choque el equipo autom ticamente deja de disparar Pulsando la tecla de Funci n F2 o pulsando otra vez el pedal se puede activar nuevamente el disparo de las ondas de choque Pedale Rilasciate l onda d urto premendo l interruttore a pedale Interrompendo l azionamento dell interruttore a pedale termina il rilascio dell onde d urto IS Arresto automatico di onde d urto al raggiungimento di 4000 onde d urto la funzione di rilascio dell onda d urto si arresta automatica mente Azionando il tasto funzione F2 oppure azionando nuovamente l interruttore a pedale viene attivata nuovamente la funzione di rilascio dell onda d urto Fotpedal Chockv gen utl ses genom att trampa p fotpedal Genom att sl ppa upp fotkontakten avbryts chock v gsutl sningen ES Automatiskt chockv gsstopp efter att 4000 tryckv gor avgetts stannar chockv gsutl s ningen automatiskt Genom att trycka pa knappen Funktion F2
59. enerator Error in high voltage generator Error in high voltage generator or HV communication cable between processor PCB and high voltage generator defective HV communication cable between processor PCB and high voltage generator defective Memory module in device defective Memory module in handpiece defective Error on processor PCB Error on processor PCB Data error in handpiece storage module Handpiece is not programmed Handpiece is not approved for this device Handpiece is close to the end of its service life approx 100 000 shock waves in reserve Handpiece is close to the end of its service life approx 50 000 shock waves in reserve Handpiece is at the end of its service life shock wave triggering no longer possible Ar the problem canot be solved with this table please contact the service department or return the device for repair Do not attempt a repair by yourself Device error Device is not functional No shock wave 84 Possible cause Corrective action Power switch is not ON Actuate the power switch The power cable is not connected Connect the power cable No line mains voltage Check in house power supply Line mains fuse defective Replace line mains fuse Foot pedal not connected or defective Connect or replace foot pedal Corrective action Connect the handpiece Contact service departmen Contact service departmen Contact service departmen Contact service departmen Contact service departmen
60. ensiteten Om en av de b da knapparna h lls intryckt blir tryckv gsintensiteten automatiskt inst lld p det l gsta resp h gsta v rdet Frekvens F r enstaka pulser ska pulsfrekvensen st llas in p 0 F r kontinuerliga pulser st lls nskad pulsfrekvens in B rja med lag tryckv gsintensitet och ka sedan gradvis intensiteten beroende pa indikationerna Vid behandling av st rre terapiomraden ar det bra att successivt flytta fokus till olika omraden 25 Foot pedal Trigger the shock waves by pushing down the foot pedal Releasing the foot pedal stops shock wave triggering Automatic shock wave stop after 4 000 shock waves or preselect maximum shock wave triggering is automatically stopped Actuate the F2 function button or operate the pedal again to reactivate shock wave triggering 26 P dale de commande Actionner la p dale de commande pour d clencher une onde de choc Rel cher la p dale de commande interrompt le d clenchement des ondes de chocs ES Arr t automatique de l onde de choc apr s avoir atteint 4000 ondes de choc le d clen chement s arr te automatiquement En actionnant la touche de Fonction F2 ou en actionnant de nouveau la p dale le d clenchement de l onde de choc est de nouveau activ Fu schalter Die Sto wellen werden durch Dr cken des Fu schalters ausgel st Durch Unterbrechung der Fu schalterbet tigung wird die Sto wellenabgabe be
61. entre la Avisar al servicio t cnico tarjeta PCI del procesador y el generador de alta tensi n Err5 Averiado el cable de comunicaci n de alta tensi n entre la tarjeta PCI del procesador y el genera Avisar al servicio t cnico dor de alta tensi n Err6 Averiado el m dulo de memoria en el aparato Avisar al servicio t cnico Err7 Averiado el m dulo de memoria en la mango Avisar al servicio t cnico Err8 Error en la tarjeta PCI del procesador Avisar al servicio t cnico Err 9 Error en la tarjeta PCI del procesador Avisar al servicio t cnico Err 10 Error de datos en el m dulo de memoria de la mango Avisar al servicio t cnico Err 11 Mango no est programada Avisar al servicio t cnico Err 12 Mango no est homologada para el equipo Conectar una mango homologada Parpadea la indicaci n de on Vida til de mango casi terminada quedan unas 100 000 ondas de choque das de choque Vida til de mango casi terminada quedan unas 50 000 ondas de choque Pulsar la tecla Funci n F2 para que deje de par padear Ya no es posible apagar la indicaci n intermitente Indicaci n de ondas de choque Ha terminado la vida til de la mango ya no se puede disparar ninguna onda de choque Conectar una nueva mango End ANsi no fuera posible eliminar los errores con la ayuda de la tabla de abajo habr que avisar al servicio de asistencia t cnica o enviar el producto a la f brica para su reparaci n Abst ngase de repararlo
62. er points in the areas of the Upper extremities Shoulder girdle Hip area Lower extremities TERAPIA DE TRIGGER POINTS POR ONDAS DE CHOQUE TPST Indicaciones Terapia de trigger points por ondas de choque TPST Endurecimiento muscular cr nico doloroso los llamados trigger points miofasciales en las regiones de Extremidades superiores Cintura escapular Regi n de la cadera Extremidades inferiores TH RAPIE DES TRIGGER POINTS PAR ONDES DE CHOC TPST Indications Th rapie des trigger points par ondes de choc TPST Tensions musculaires douloureuses chroniques appel es trigger points dans les r gions suivantes Membres sup rieurs Ceinture scapulaire R gion pelvienne Membres inf rieurs TERAPIA AD ONDE D URTO SU TRIGGER POINT TPST Indicazioni Terapia ad onde d urto focalizzate su trigger point TPST Forme croniche di contrazioni muscolari dolorose altri trigger points miofasciali nelle zone Estremit superiori Cintura scapolare Regione dell anca Estremit inferiori TRIGGER PUNKT STOSSWELLEN THERAPIE TPST Indikationen Trigger Punkt Sto wellen Therapie TPST Chronische schmerzhafte muskul re Verspan nungen sogenannte myofasziale Triggerpunkte in den Bereichen Obere Extremit ten Schulterg rtel H ftregion Untere Extremit ten TRIGGERPUNKTBEHANDLING MED TRYCKV GOR TPST Indikationer Triggerpunktbehandling med tryckv gor Kroniska
63. era att applikatorns anslutningsslang inte har n gra skador Gelplattan m ste avl gsnas fr n applikatorn Applikatorns gelplattans och bajonettringens ytor ska reng ras och desinficeras med ytdes infektionsmedel Kontroller varje m nad Kontrollera att etiketter och m rkning som kr vs f r att s kert kunna anv nda apparaten r l sliga Etiketter och m rkning som inte l ngre r l sbara och som kan leda till felaktigt handhavande och f rberedande ska bytas Kontrollera att applikatorns yta inte har n gra skador Kontrollera applikatorns kapacitet 49 Fuses A Replace exclusively with the type of fuse shown on the back of the unit IS Should legal provisions in your country demand shorter intervals these must be observed ES To comply to standard IEC 60601 1 about technical and safety tests as well as intervals of maintenance the user must follow local laws and regulations in the country where the device is in operation This maintenance can be carried out by EMS or an approved repair center 50 Fusibles A Remplacez uniquement par le type de fusible mentionn au dos de l appareil ES Si les dispositions l gales en vigueur dans votre pays pr voient des intervalles de mainte nance plus courts il convient de s y conformer I En respect de la norme IEC 60601 1 quant la tenue de tests techniques et de s curit ai
64. ervdelar som inte r original anv nds Produkten transporteras b st i originalf rpack ningen Den skyddar produkten mot skador under transporten A Reng r desinficera och sterilisera produkten och alla tillbeh r enligt beskrivningarna i bruksanvisningen innan du skickar iv g dem Ange terf rs ljarens namn om du skickar produkten direkt till ett godk nt EMS reparations center Detta underl ttar hanteringen 67 SYMBOLS Unit GCG Ve Bee 68 SYMBOLES Appareil Manufacturer s logo Logo du fabriquant Herstellerlogo Caution Attention Achtung Refer to instruction manual Se r f rer au manuel d utilisation Gebrauchsanweisung beachten Applied part type BF Partie appliqu e du type BF Anwendungsteil Typ BF Alternating current AC Tension alternative Wechselspannung Data transfer Transfert de donn es Datentransfer Footpedal connection Connexion pour la p dale de commande Anschluss Fu schalter Fuse Fusible Sicherung Standby ON key with control lamp Touche Veille Marche avec voyant de contr le Betriebsbereitschaft Ein mit Kontrolllampe SYMBOLE Ger t S MBOLOS Aparato GIRA Bee SIMBOLI Apparecchio Logotipo del fabricante Logo del produttore Tillverkarens logotyp Precauci n Attenzione Akta Referirse a los instrucciones de empleo Riferirsi a le istruzioni per l uso Se till anvisningshandboken Pieza de aplicaci n tipo BF Parte appli
65. es complications s v res n ont pas pu tre constat es Effets secondaires Apparition de H matomes locaux p t chies locales Irritations locales de la peau CEd mes locaux Extrakorporale Sto wellen Therapie ESWT Indikationen Tendinosis calcarea der Schulter Subakromiales Schmerzsyndrom Epicondylitis humeri radialis ulnaris Patellaspitzensyndrom Tibiakantensyndrom Tendinopathien der Achillessehne Plantarfasziopathie Pseudarthrosen Kontraindikationen Lokale Infektionen Lokale Tumorleiden Gerinnungsst rungen vorherige Gerinnungs statusabkl rung notwendig Einnahme von blutverd nnenden Medika menten Schwangerschaft Lungengewebe im Sto wellenbereich Kinder mit offenen Wachstumsfugen Komplikationen Komplikationen ernst zu nehmender Art sind bislang nicht beobachtet worden Nebenwirkungen Auftreten von Lokalen H matomen Petechien Lokalen Hautreizungen Lokalen Odemen Tratamiento extracorporal por ondas de choque ESWT Indicaciones Tendinosis calcificante del tend n del supraespinoso S ndrome de pinzamiento del hombro Epicondilitis humeral radial ulnar S ndrome patelo femoral Dolor de tibia anterior Aquilodinia Fasciitis plantar con espol n calc neo Seudoartrosis Contraindicaciones Infecciones locales Tumores locales Trastornos de coagulaci n previamente se tienen que verificar los factores relativos a la coagulaci n Toma de
66. g des Handst cks Vertreiber Hersteller Modell Klassifikation EN 60601 1 Aperturwinkel Aperturdurchmesser Energieflu dichte positiv Druckbereich Fokusgr e min bis max fx 6dB fy 6dB fz 6dB Fokusvolumen Pulsfrequenz Intensit tsstufen Gesamtenergie E 5 mm Eindringtiefe Gewicht Betriebsbedingungen Lager und Transportbedingungen EMS SA CH 1260 Nyon Schweiz RICHARD WOLF GmbH 75438 Knittlingen Deutschland Handst ck F10 G4 f r Swiss PiezoClast Klasse Anwendungsteil Typ B IP 20 94 100 mm 0 03 bis 0 4 mJ mm 11 5 bis 82 2 MPa 1 2 bis 2 8 mm 5 0 bis 14 1 mm 58 mm 1 bis 8 Hz 20 Stufen 9 54 mJ 5 bis 40 mm ca 1 2 kg ca 2 7 lbs 10 C bis 35 C 30 bis 75 rel Feuchte Luftdruck 700 hPa bis 1060 hPa 5 C bis 40 C 10 bis 90 rel Feuchte Luftdruck 700 hPa bis 1060 hPa ESPECIFICACIONES T CNICAS Denominaci n del aparato Distribuidor Fabricante Modelo Clasificaci n EN 60601 1 Clasificaci n 93 42 CE Tensi n alimentaci n Frecuencia red Potencias nominales Nivel de ruido Fusible Modo de funcionamiento Peso Medidas long x anch x alt Condiciones funcionamiento Condiciones almacenamiento y transporte EMS SA CH 1260 Nyon Suiza RICHARD WOLF GmbH 75438 Knittlingen Alemania Swiss PiezoClast Clase Pieza de aplicaci n tipo B IP 20 aparato IP X8 pedal el ctrica Modo de utilizaci n continua
67. i tecnici F RVARING AV PRODUKTEN ES Beh ll originalf rpackningen tills produkten skall skrotas permanent F rpackningen kan alltid anv ndas till transport eller f rvaring Vid f rvaring och transport av gelplattor ska d rf r avsedd f rvaringsbox anv ndas G r s h r om produkten skall st llas av under l ngre tid e F lj anvisningarna i avsnittet Aterbear betning L gg produkten och alla tillbeh r i originalf r packningen F rvarings och transportf rh llanden beskrivs i avsnittet Tekniska data 63 PRODUCT DISPOSAL The product must not be discarded in domestic household waste Should you wish to definitively dispose of the product please comply with the regulations which apply in your country Waste Electrical and Electronic Equipment belonging to customers located in the European Union may be shipped to EMS for recycling in accordance to the WEEE regulations The costs of recycling exclusive of shipping fees are covered by EMS WARRANTY Damages due to non adherence to the operating instructions or wear out of parts are excluded from warranty gt The warranty of your product will be cancelled if you try to open it ACCESSORIES Accessories are available from EMS or any authorized dealer Please contact your customer service directly 64 RECYCLAGE Le produit ses accessoires et son emballage ne contiennent pas de substances dangereuses pour l environnement Si v
68. ia a la norma 93 42 CE inclusive EN 60601 1 y EN 60601 1 2 Simbolo di conformit CE Si riferisce alla direttiva 93 42 CE come anche alle norme EN 60601 1 e EN 60601 1 2 CE m rkning enligt direktiv 93 42 EG inklusive EN 60601 1 och EN 60601 1 2 Tratamiento de los equipos el ctricos y electr nicos al final de su vida til Aplicable en la Uni n Europea y en pa ses europeos con sistemas de recogida selectiva de residuos Trattamento del dispositivo elettrico od elettronico a fine vita Applicabile in tutti i paesi dell Unione Euroea e in quelli con sistema di raccolta differenziata Omh ndertagande av gamla elektriska och elektroniska produkter g ller i Europeiska unionen och andra europeiska l nder med separata insamlingssystem Tierra equipotencial Messa a terra equipotenziale Ekvipotentialjordning 73 Handpiece 74 m E Piece a main Unlocked Deverrouill amp Entriegelt Locked Verrouill Verriegelt Handst ck Mango ED ED Manipolo Desbloqueado Sbloccato ppen Bloqueado Bloccato L st Handstycke 75 TECHNICAL DATA Description of the unit Distributor Manufacturer Model Classification EN 60601 1 Classification 93 42 EC Supply voltage Mains frequency Power consumption Noise level Fuses Operating mode Weight Dimensions in mm LxWxH Operating conditions Storage and transport conditions 76 EMS SA CH 1260 Nyon Switzerland RICHARD WOLF GmbH 75438 Knit
69. icazione 93 42 CE Tensione di alimentazione Frequenza di rete Potenza nominale Livello di rumorosit Fusibili Modo operativo Peso Dimensioni Lx Lx A Condizioni di funzionamento Condizioni di stoccaggio e di trasporto 80 EMS SA CH 1260 Nyon Svizzera RICHARD WOLF GmbH 75438 Knittlingen Germania Swiss PiezoClast Classe Parte applicata del tipo B IP 20 apparecchio IP X8 pedale di comando elettrico Modo funzionamento continuo Classe IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A TITEL Modo a impulsione continuo Frequenza di repetizione 1 20 Hz environ 14 5 kg environ 30 8 Ibs 395 mm x 400 mm x 170 mm Tra 10 C e 35 C umidit relativa tra 30 e 75 pressione dell aria tra 700 hPa e 1060 hPa Tra 5 C e 40 C umidit relativa tra 10 e 75 pressione dell aria tra 700 hPa e 1060 hPa Descrizione del manipolo Distributore Costruttore Modello Classificazione EN 60601 1 Angolo d apertura Diametro apertura Densit del flusso di energia positiva Campo pressore Dimensione fuoco min a max fx 6dB fy 6dB fz 6dB Volume fuoco Frequenza d impulso Livelli d intensita Energia complessiva E 5 mm Profondit di penetrazione Peso Condizioni di funzionamento Condizioni di stoccaggio e di trasporto EMS SA CH 1260 Nyon Svizzera RICHARD WOLF GmbH 75438 Knittlingen Germania Manipolo F10 G4 per Swiss PiezoClast Classe Parte
70. igt med ultraljudgel mitt p Aplicar una cantidad suficiente de gel para Sulla parte centrale della superficie di applikatorns kontaktyta ultrasonido en el centro de la superficie de contatto del manipolo applicate una quantit Montera gelplattan utan luftbl sor contacto del mango sufficiente di gel per ultrasuoni Colocar la almohadilla de gel de tal manera Collocate il gelpad evitando la formazione di que no haya burbujas de aire algunas bolle d aria Push down the gel pad while moving it back and forth slightly until the ultrasound gel is slightly squeezed out around the circum ference of the pad Align the marking to install the twist lock ring Turn clockwise to lock Removing the gel pad 14 Turn the twist lock ring counter clockwise and remove it Before lifting the twist lock ring make sure that the dots are aligned Remove the gel pad Reprocess the gel pad and the handpiece in accordance with Chapter Reprocessing Appuyer sur le gel pad en le tournant dans un sens et dans l autre jusqu ce que le gel de contact ressorte l g rement tout autour du bord du gel pad Mettre la bague a baionnette en place Verrouiller en tournant dans le sens des aiguilles d une montre Enl vement du gel pad D verrouiller la bague ba onnette en tournant dans le sens inverse des aiguilles d une montre et la retirer Veiller pour ceci ce que les points de rep re coincident au moment o
71. in das Ger t eindringen Gefahr eines elektrischem Schlags Vor der Aufbereitung das Ger t abschalten und vom Versorgungsnetz trennen Das Ger t kann mit einem weichen Tuch das mit Oberfl chendesinfektionsmittel oder Alkohol befeuchtet ist gereinigt werden Die Angaben des Desinfektionsmittelherstellers beachten Es ist darauf zu achten dass keine Feuch tigkeit in das Ger t eindringt F r die Pflege des Ger ts d rfen keine Putz Scheuer oder L sungsmittel eingesetzt werden Aufbereitung des Fu schalters A Feuchtigkeit kann in den Fu schalter eindringen Gefahr eines elektrischem Schlags Den Fu schalter bzw Stecker nicht in Wasser eintauchen oder unter flie endem Wasser reinigen Der Fu schalter kann mit einem weichen Tuch das mit Oberfl chendesinfektionsmittel oder Alkohol befeuchtet ist gereinigt werden Die Angaben des Desinfektionsmittelherstellers beachten REPROCESAMIENTO Reprocesamiento del equipo Mm Riesgo de penetraci n de humedad en el equipo Peligro de choque el ctrico Antes de la preparaci n del equipo se ha de desconectarlo y separarlo de la red de alimentaci n El aparato se puede limpiar con un pa o suave humedecido con un desinfectante para superficies O alcohol Observe las indicaciones del productor del desin fectante T ngase cuidado en que no entre humedad alguna en el aparato Para los cuidados del aparato no se deben utilizar detergentes agentes de restreg
72. in doit tre retrait e apr s chaque emploi conform ment aux instructions du chapitre Retraitement N utiliser que les gels de contact certifi s pour tre utilis s sur les patients Observer les instructions du fabricant du gel Die maximal m gliche Eindringtiefe von ca 40 mm wird erreicht wenn das niedrigste Gelpad ohne Bezeichnung verwendet wird Ultraschallgel gleichm ig und luftblasenfrei auf das Gelpad und das Therapiefeld auftragen Das Handst ck senkrecht auf die Indikationsstelle aufsetzen Die Zentrierspitze B und die Leitlinien C dienen der Orientierung bzw Ausrichtung beim Aufsetzen des Handst cks auf demTherapiefeld Das Handst ck nach jeder Anwendung entsprechend Kapitel Aufbereitung behandeln Nur f r Patientenanwendung zugelassene Ultraschallgels verwenden Die Angaben des Gelherstellers beachten La m xima profundidad de penetraci n posible de unos 40 mm se logra con la almohadilla de gel m s baja sin marcaci n Aplicar el gel para ultrasonido uniformemente en la almohadilla y el paciente evitando que haya burbujas de aire Posicionar el mango verticalmente en el lugar de la indicaci n La punta de centraje B y las l neas de gu a C sirven de orientaci n y gu a a la hora de posicionar la mango respecto del campo a tratar Despu s de cada uso el mango se debe someter a la preparaci n descrita en el cap tulo Retratamiento Utilice solamente geles para ultr
73. inflamables A Este producto deber ser utilizado nica mente por personal cualificado y formado para ello A Compruebe antes de cada tratamiento que su producto no presenta defectos Un accesorio o un aparato da ado no se debe utilizar Deben sustituirlo Utilice nicamente piezas y accesorios originales EMS A La reparaci n de este producto debe ser llevada a cabo exclusivamente por un agente autorizado por EMS A Rischio d esplosione non usare questo prodotto in presenza di gas o anestetici infiam mabili Mm Questo prodotto deve essere utilizzato esclusivamente da personale qualificato e formato Controllare il prodotto prima di ogni tratta mento In caso di danni all apparecchio o agli accessori questi non devono essere usati ma sostituiti Utilizzare solamente pezzi di ricambio originali EMS N Effettuare le riparazioni al prodotto solo da terzi abilitati da EMS A Explosionsrisk anv nd inte denna produkt vid n rvaro av brandfarliga anestetika eller gaser A Denna produkt f r endast anv ndas av utbildad och kvalificerad personal Unders k alltid Era produkter s att de ej r skadade f re anv ndning En skadad produkt f r inte anv ndas utan skall ers ttas Anv nd endast originala EMS reservdelar och tillbeh r Reparera denna produkt endast hos EMS auktoriserad service 61 STORING THE PRODUCT IS Keep the original packaging until the product is to be disposed of permanently You ca
74. ing or identi fication which may lead to wrong handling and reprocessing must be reinstated Check the contact surface of the handpiece for damage Check the power output of the handpiece 48 MAINTENANCE Intervalles d entretien AN Pour viter tout incident ou dommage caus par le vieillissement et l usure il est n cessaire d entretenir le produit et ses accessoires des intervalles ad quats Selon la fr quence d uti lisation mais au minimum une fois par an un technicien sp cialis doit inspecter la s curit de fonctionnement du produit Contr les quotidiens V rifier que la pi ce main et les accessoires ne pr sentent ni d fectuosit s ni pi ces d tach es ou manquantes ni encrassement V rifier l tat parfait du cordon de raccordement de la pi ce main V rifier que le gel pad a t enlev de la pi ce main La surface de contact de la pi ce main le gel pad et la bague baionnette doivent tre parfaitement nettoy s et d sinfect s l aide d un d sinfectant pour surfaces Contr les mensuels V rifier que les inscriptions et marquages n ces saires l emploi s r et conforme la destination sont lisibles L absence ou l illisibilit d un marquage et d une inscription qui risquerait de causer une manipu lation ou un retraitement inad quats impose leur remise en tat V rifier l tat parfait de la surface de contact de la pi ce main V rifier l ne
75. intensity to stage 20 Select pulse rate 1 Trigger a shock wave The output power of the handpiece is still sufficient if the height of the jet exceeds 10 cm IS If the height of the jet is less than 10 cm contact the service department 54 Veiller ce que les 3 broches du verrouillage baionnette rentrent dans les rainures pr vues cet effet dans le support Fermer les 3 dispositifs de serrage rapide Veiller pour chaque dispositif de serrage rapide d passer le point de verrouillage marqu par une r sistance m canique et un d clic Remplir ensuite le cylindre d eau jusqu au rep re M voir fig 2 Regler l intensit des ondes de choc au niveau 20 Regler la fr quence d impulsion au niveau 1 D clencher l onde de choc Si la hauteur du jet d eau produit est de plus de 10 cm l nergie de la pi ce main est suffisante RSP Si la hauteur du jet d eau produit est inf rieure a 10 cm contacter le Service apr s vente Darauf achten dass die 3 Stifte des Bajonettver schlusses in die Einfrasungen des Handst ck halters eingesetzt werden Die 3 Schnellspanner schlieRen Darauf achten dass der Verriegelungspunkt des jeweiligen Schnellspanners sp r und h rbar berdr ckt wird Pr fzylinder mit Wasser bis F llmarke M f llen Abb 2 Die StoRwellenintensitat auf Stufe 20 einstellen Pulsfrequenz 1 einstellen Sto welle ausl sen Betr gt die Spritzh he der Font ne mehr
76. kningar Kan upptr da Lokala hematomer petekier Lokala hudirritationer Lokala dem Extracorporeal Shock Wave Therapy ESWT Indications Calcifying tendinitis of the shoulder Subacromial pain syndrome Epicondylitis humeri radialis ulnaris Patella tip syndrome jumper s knee Medial tibial stress syndrome Achilles tendinopathy Plantar fasciopathy Pseudarthroses Contraindications Local infections Local tumor diseases Clotting disorders before use coagulation status analysis is necessary Use of haemo diluting medication Pregnancy Lung tissue in the shock wave entry window Children with open epiphyses Complications Serious complications have not been observed Side effects Occurrence of Local haematomas petechiae Local irritation of the skin Local edemas Th rapie extra corporelle par ondes de choc ESWT Indications Tendinite calcifiante de l paule Impingement syndrome de l paule Epicondylite hum ro radiale ou ulnaire Syndrome de la pointe rotulienne Syndrome tibial Achillodynie Fasciite plantaire avec pine de Lenoir Pseudarthroses Contre indications Infections locales Tumeurs locales Troubles de la coagulation pr voir une v rifi cation de l tat de la coagulation auparavant Prise de m dicaments anticoagulants Grossesse Pr sence de tissu pulmonaire dans la r gion des ondes de choc Enfanten croissance piphysaire Complications D
77. kten tar inte p sig ansvaret f r varken direkt eller indirekt skada som resultat av felhantering eller ignorering av bruksanvisningen eller felaktig f rberedelse och underh ll A Kontraindikation ultraljudssv ngningar kan g ra att pacemakers och defibrillatorer inte fungerar korrekt D rf r rekommenderar vi att man inte behandlar patienter med pacemaker eller defibrillator med denna produkt A F r patienter med smittsamma sjukdomar m ste f ljande s kerhets tg rder vidtas e F re behandling ska ppna s r f rbindas s att inga kroppsv tskor kan l cka ut Efter behandling ska enheten desinficeras Beakta anvisningarna fr n tillverkaren av desinfektionsmedel A Tryckv gor b r undvikas mot organ som innesluter luft t ex lungor tarmar Var noga med hur applikatorn riktas resp hur patienten placeras Tryckv gor kan ge upphov till o nskade hj rtreaktioner A Anv nds endast till avsett ndam l Brist f llig inl rning av bruksanvisningen kan resultera i skador hos patient eller anv ndaren eller ge skador p produkten som i v rsta fall blir orepa rerbar F re f rsta anv ndning av produkten se till att Ni har studerat bruksanvisningen noga Detta g ller ven andra produkter som anv nds tillsammans med denna apparat 59 Mm Risk of explosion do not use this product in the presence of inflammable anaesthetics or gases A This product must be used only by trained and qualified personnel
78. l paciente sentado o tendido dec bito dorsal Sindrome degli spigoli tibiali Posizione del paziente seduto o sdraiato a pancia in su Medialt tibiasyndrom Placering sittande eller liggande ryggl ge 39 Recommendation for shock waves therapy ESWT Mm Be careful when using exces sively high shock wave rates High shock wave rates may damage the tissue Do not apply more shock waves during one treatment session than the number specified Recommandation pour le traitement par ondes de chocs ESWT A Des l sions tissulaires risquent d appara tre en cas d une utilisation excessive d ondes de choc Ne pas appliquer plus d ondes de choc par traitement que pr conis Indication Intensity Tendinosis calcarea 6 10 Epicondylitis humeri radialis 3 6 Epicondylitis humeri ulnaris 3 6 Achilles tendinopathy 4 6 Plantar fasciitis 6 10 Patella tip syndrome 3 6 Empfohlene f r Sto wellen Therapie ESWT A Vorsicht bei zu hoher Anzahl Stosswellen m gliche Gewebe sch digungen Pro Behandlung nicht mehr StoRwellen applizieren als angegeben 40 Application Intensit Tendinopathie calcifiante 6 10 picondylite hum ro radiale 3 6 picondylite hum ro ulnaire 3 6 Tendon d Achille achillodynie 4 6 Fasciite plantaire 6 10 Genou syndrome rotulien 3 6 Einsatzgebiete Intensit t Tendinosis calcarea 6 10 Epicondylitis humeri radialis 3 6 Epicondylitis humeri ulnaris 3 6 Achillodynien 4 6 Plantarfasciitis 6 10 Pa
79. la bague baionnette est soulev e Enlever le gel pad Traiter le gel pad et la pi ce main confor m ment aux instructions du chapitre Retrai tement Das Gelpad andr cken und dabei leicht hin und herdrehen bis rund um den Gelpadrand das Ultraschallgel leicht herausquillt Bajonettring aufsetzen und im Uhrzeigersinn verriegeln Darauf achten dass beim Aufsetzen die Markierungspunkte bereinstimmen Gelpad entfernen Bajonettring gegen den Uhrzeigersinn entriegeln und entfernen Darauf achten dass beim Abheben des Bajonettrings die Markierungspunkte bereinstimmen Gelpad entfernen Das Gelpad und die Therapiequelle entsprechend Abschnitt Aufbereitung handhaben Apretar la almohadilla de gel gir ndola levemente en ambos sentidos hasta que un poco de gel salga por toda la circunferencia de la almohadilla Colocar el anillo de bayoneta Inmovilizarlo girando en el sentido de las agujas del reloj cuidando de que coincidan los puntos de orientaci n Quitar la almohadilla de gel Desbloquear el anillo de bayoneta girando en sentido contrario a las agujas del reloj y quitarlo Al levantar el anillo de bayoneta cerci rese de que coincidan los puntos de orientaci n Quitar la almohadilla de gel Someter la almohadilla de gel y el mango a la preparaci n descrita en el cap tulo Reproce samiento Premete il gelpad e ruotate lievemente avanti e indietro fino a che il gel per ult
80. las tapas de este manual para ver los dibujos Vik ut omslagen f r att se inneh llsf rteckning och skisser TECHNISCHE NDERUNGEN EMS beh lt sich vor im Zusammenhang mit technischen oder wissenschaftlichen Weiterent wicklungen nderungen an der Technik dem Zubeh r der Bedienungsanleitung sowie am Inhalt der Originalverpackung vorzunehmen TEKNISKA MODIFIKATIONER EMS reserverar sig f r r ttigheten att modifiera tekniken tillbeh ren bruksanvisningen eller inneh llet i detta set vid framtida teknisk eller vetenskaplig utveckling 10 11 12 13 14 15 16 17 18 CT 26 COMPONENTS 1 Unit 2 Shockwave intensity Intensity display 3 Shock wave counter Impulse Count and Status and error message display 4 Pulse rate Frequency indicator 5 Increase shock wave intensity button 6 Reduce shock wave intensity button 7 Increase pulse rate button 8 Reduce pulse rate button 9 Standby button 10 Standby indicator 11 Preselection button for number of shock waves 12 Reset button 13 Function 1 button 14 Function 2 button 15 Connecting socket for the handpiece 16 Handpiece holder 17 Connector 18 Foot pedal 19 Power cable 20 Power switch 21 Power input connector with fuse holder 22 Connecting socket for foot pedal 23 Data interface only for service 24 Potential equalization connector 25 Fan 26 Fuses 27 Gel bottle
81. last EMS Si el aparato est utilizado cerca de un Swiss DolorClast no se ha de enchufar ambos aparatos al mismo tiempo Adem s antes de utilizarlo se debe controlar su buen funciona miento en las condiciones de utilizaci n AN El uso de accesorios y cables distintos a los especificados o vendidos por EMS como piezas de repuesto puede dar lugar a un aumento de las emisiones o a la reducci n de la inmunidad de este producto COMPATIBILIT ELETTROMAGNETICA RSP Questo prodotto necessita di precauzioni speciali riguardo alla compatibilita elettroma gnetica e deve essere installato e messo in funzione secondo la nota Compatibilita Elettro magnetica I Certi tipi di apparecchi di telecomunicazione mobile potrebbero potenzialmente interferire con questo prodotto Tenere conto delle distanze di separazione raccomandate nella nota Compati bilit Elettromagnetica AN Questo prodotto non pu essere utilizzato a prossimita di un altro apparecchio o impilato su quest ultimo eccezione fatta per l implilamento con il Swiss DolorClast di EMS Se l apparecchio utilizzato a prossimit di un Swiss DolorClast non mettere contemporaneamente i due apparecchi Sotto tensione Inoltre imperativa prima dell uso e nelle condizioni d uso la verifica del suo buon funzionamento N Lutilizzo di accessori o cavi diversi da quelli specificati o venduti da EMS come parti di ricambio pu avere come conseguenza un aumento delle emissio
82. last e il manipolo collegata all apparecchio sono pronti per l uso ANV NDA ENHETEN Kontroller A Kontrollerna ska genomf ras f re och efter varje anv ndning Anv nd inte l ngre apparaten om den r skadad saknar delar eller har l sa delar Skicka skadad produkt tillsammans med l sa delar f r reparation F reta inga egna reparationsf rs k Okul r kontroll Kontrollera att apparat och tillbeh r inte har n gra skador l sa eller saknade delar j mte hygieniskt skick och skick i vrigt Kontrollera att n tanslutningen inte har n gra skador Kontrollera att etiketter och m rkning som kr vs f r att s kert kunna teranv ndas apparaten r l sliga Etiketter och m rkning som inte l ngre r l sbara och som kan leda till felaktigt handhavande eller f rberedelser m ste bytas Kontrollera att applikatorns yta inte har n gra skador Utf r en kontroll av applikatorn i verensst m melse med bruksanvisningen f r denna i kapitlet Underh ll Funktionskontroll Anslut applikatorn till apparaten och sl p str m brytaren Apparaten utf r automatiskt ett sj lvtest Om inga fel signaleras r Swiss PiezoClast och den anslutna applikatorn klara att anv ndas 11 Preparing the handpiece Installing the gel pads A Use only ultrasound gels certified for use on patients Follow the gel manufacturer s instruc tions Installing the gel pad Apply a sufficient amount of ult
83. lectriques en un werden die von den im Handst ck angeordneten mounted into the handpiece in one single therapy foyer de traitement F Piezoelementen ausgel sten Druckwellen S in focus F L nergie est transmise dans le corps de mani re einem Therapiefokus F geb ndelt The energy is coupled into the body in a focussed focalis e Die Energie wird fokussiert in den K rper einge manner koppelt 30 Principio de funcionamiento del Principio di funzionamento del Funktionsprincip mango manipolo La forma del mango provoca la concentraci n de La forma del manipolo focalizza le onde di P grund av applikatorns uppbyggnad koncen las ondas de presi n S de todos los piezoele pressione S di tutti gli elementi piezoelettrici in treras tryckv gorna S i ett terapifokus F mentos en un foco terap utico F un fuoco di terapia F Energin verf rs fokuserat till kroppen La energia focalizada se aplica al cuerpo L energia amp trasmessa nel corpo in modo focalizzato 31 Treatment sequence using the handpiece Position the patient on a treatment table or chair ensuring a stable position Make sure that the therapy area is easily accessible Draw a landmark limits of the treatment field on the patient s skin e g with a felt tip pen Choose a suitable gel pad to obtain the necessary penetration depth The number on the gel pad A corresponds to the penetration depth E of the therapy focus F in mm see Figs 1
84. luidos los accesorios en intervalos razonables Seg n la frecuencia de uso pero como m nimo una vez al afio un especialista en la materia tiene que comprobar la seguridad de funcionamiento y la fiabilidad operacional Controles a efectuar cada d a Comprobar el mango y los accesorios en cuanto a dafios piezas sueltas o faltantes higiene e integridad Examinar el tubo flexible de conexi n al mango para ver si se hubiere producido alg n dafio Se tiene que quitar la almohadilla de gel del mango La superficie de contacto del mango la almohadilla de gel y el anillo de bayoneta se deben limpiar y desinfectar con un desinfectante para superficies Controles a efectuar cada mes Los r tulos y las marcaciones necesarios para la aplicaci n segura y adecuada a su fin han de estar legibles Se han de restablecer todos aquellos r tulos y marcaciones faltantes e ilegibles que llevan a errores en el manejo y el reprocesamiento Comprobar la superficie de contacto del mango en t rminos de da os Comprobar la energ a del mango MANUTENZIONE Intervalli di manutenzione A Per evitare eventi spiacevoli e o danni che possono insorgere per l invecchiamento e Pusura dell apparecchio e dei relativi accessori la manutenzione deve essere eseguita ad intervalli adeguati A seconda della frequenza di utilizzo tuttavia almeno ogni 12 mesi fate verificare da un tecnico specializzato la sicurezza funzionale dell apparecchio Cont
85. n use it for shipping or storing at any time Use the storage box provided for the storage and transport of the gel pads If the unit is not going to be used for an extended period of time Proceed as described in the chapter Reprocessing Pack the product and all accessories in the original packaging Please refer to the storage and transport condi tions in the Technical data 62 RANGEMENT DU PRODUIT RSP Nous vous conseillons de conserver l emballage d origine jusqu la mise au rebut de votre produit Vous pouvez ainsi l utiliser tout moment pour le rangement ou le transport Utiliser la boite de stockage fournie pour le stockage et le transport des gel pads Si vous envisagez de ne pas utiliser votre produit durant une p riode prolong e Suivez les tapes d crites au chapitre Retraitement Rangezle produit et les accessoires dans l emballage d origine Veuillez tenir compte des conditions de stockage et de transport d crites au chapitre Caract ris tiques techniques AUFBEWAHREN DES PRODUKTES ES Bewahren Sie die Originalverpackung bis zur endg ltigen Entsorgung Ihres Produktes auf Sie k nnen diese so jederzeit f r den Transport oder die vor bergehende Lagerung des Produktes verwenden Zum Aufbewahren und Transport der Gelpads sollte die daf r vorgesehene Aufbewahrungsbox verwendet werden Wenn Sie Ihr Produkt l ngere Zeit nicht benutzen wollen Gehen Sie entsprechend dem
86. nali in vigore nel vostro paese L apparecchiatura elettronica ed elettrica fuori uso appartenente a clienti residenti nella UE potr essere spedita a EMS per il riciclaggio in conformit alle normative RAEE Il costo del riciclaggio eccetto i costi di spedizione sar a carico di EMS GARANZIA I danni derivanti da usura e dal non rispetto di queste istruzioni d uso sono esclusi dalla garanzia IS La garanzia del vostro prodotto sar annullata se provate ad aprirlo ACCESSORI Troverete gli accessori presso la EMS oi rivenditori autorizzati Vogliate contattare diret tamente il vostro servizio clientela KASSERING AV PRODUKTEN Produkten dess tillbeh r och emballage inneh ller inget material som r skadligt f r milj n F lj g llande regler i ditt land om du vill kasta bort dem f r gott Avfall som utg rs av eller inneh ller elektriska eller elektroniska produkter WEEE Waste Electrical and Electronic Equipment som tillh r kunder inom EU kan skickas till EMS f r tervinning i enlighet med WEEE direktivet EMS st r f r tervinnings kostnaden men inte f r fraktkostnaden GARANTI Skador som uppkommit p grund av att bruks anvisningen inte f ljts samt normal f rslitning omfattas inte av garantin IS Garantin p din produkt annulleras om du f rs ker ppna den TILLBEH R Tillbeh r kan erh llas fran EMS eller auktori serad terf rs ljare Kontakta kundservice 65 EMS SE
87. nance A Contraindication ultrasonic oscillations may prevent cardiac pace makers and defibril lators from functioning properly Therefore we recommend that patients with a cardiac pace maker or a defibrillator should not be treated with this product A Patients with infectious contagious diseases require the following measures Before the treatment cover open wounds in such a way that no body fluids can leak out Disinfect the device after the treatment Follow the disinfectant manufacturer s instructions Avoid applying shock waves to organs which contain trapped air e g lung intestines Double check the entry window and position of the handpiece and position the patient as required In addition shock waves can cause undesirable heart reactions AD Use for the intended purpose only before using the product make sure that you have studied and understood the operating instructions This also applies to any equipment used with this product Failure to observe the operating instruc tions may result in the patient or user suffering serious injury or the product being damaged possibly beyond repair 58 REMARQUES DE S CURIT EMS et le distributeur de ce produit ne peuvent tre tenus responsables d ventuels pr judices directs et indirects r sultant d un emploi inad quat ou d un maniement incorrect en particulier lorsque le mode d emploi n a pas t respect ou lorsque la pr paration et l entretien n o
88. ndilite dell omero radiale e ulnare Posizione del paziente Seduto Armbage epicondylitis humeri radialis ulnaris tennis golfarmb ge Placering sittande ORTOPEDIA ESWT Posturas recomendadas Knee Jumper s knee Positioning Lying or sitting Genou syndrome rotulien Posture couch e ou assise Knie Patella Spitzensyndrom Lagerung Liegend oder sitzend Rodilla s ndrome patelo femoral Posici n del paciente tendido dec bito dorsal Ginocchio sindrome dell apice patellare Posizione del paziente sdraiato a pancia in su Kn Patella apex syndrom Placering liggande ryggl ge ORTOPEDICO ESWT Esempi di posizione Achilles tendinopathy Positioning Lying prone position Tendon d Achille achillodynie Posture couch e ventrale Achillessehne Achillodynien Lagerung Liegend Bauchlage Tend n de Aquiles aquilodinia Posici n del paciente tendido dec bito abdominal Tallone di Achille Achillodinia Posizione del paziente sdraiato a pancia in gi Akillessena Akillestendinit Placering liggande bukl ge ORTOPEDI ESWT Placeringsexempel Medial tibial stress syndrome Positioning Sitting or lying dorsal position Syndrome tibial Posture assise ou couch e dorsale Tibiakantensyndrom Lagerung Sitzend oder liegend R ckenlage Dolor de tibia anterior Posici n de
89. nfecte y esterilice el producto y todos los accesorios como se describe en las instrucciones de empleo antes de mandarlos Cuando env e el producto directamente al centro de reparaci n autorizado de EMS incluya el nombre de su distribuidor Esto simplificar el proceso SERVIZIO ASSISTENZA EMS Se il prodotto ha bisogno di un ulteriore assistenza o di riparazioni spedirlo al rivenditore o a un centro di assistenza EMS autorizzato EMS declina qualsiasi responsabilit relativa alla sicurezza del dispositivo e dichiara la garanzia nulla nel caso l assistenza o la riparazione sia effettuata da terzi non autorizzati o siano state utilizzate parti di ricambio non originali Si consiglia di spedire il prodotto nel suo imballo originale In questo modo sar protetto da danni durante la spedizione A Prima della spedizione pulire disinfettare e sterilizzare il prodotto e tutti gli accessori attenendosi alle descrizioni fornite nelle istruzioni per l uso Quando si spedisce il prodotto direttamente ad un centro di assistenza EMS approvato includere il nome del proprio rivenditore Ci semplificher il processo EMS SERVICE Om produkten beh ver service eller reparation skickar du den till din terf rs ljare eller ett godk nt EMS reparationscenter EMS fr ns ger sig allt ansvar f r enhetens s kerhet och f rklarar garantin ogiltig om service eller reparationer utf rs av en icke auktoriserad tredjepart eller om res
90. ng the sublevels Press and hold the Reset button for approx 5 seconds until shock wave intensity O is displayed 18 1 R gler l intensit des ondes de choc entre 1 et 20 Le niveau de l intensit des ondes de choc peut tre r gl l aide des touches v r duire l intensit de l onde de choc et augmenter l intensit de l onde de choc Ajuster l intensit des sous niveaux 1 En pr sence d une zone de traitement particuli rement sensible la douleur l intensit de l onde de choc du niveau 1 peut tre ajust e plus pr cis ment entre 0 0 et 0 9 2 Activer les sous niveaux Actionner la touche v r duire l intensit de l onde de choc pendant environ 2 secs jusqu ce que l intensit 0 0 soit affich e L intensit de l onde de choc peut alors tre ajust e entre 0 0 et 0 9 3 D sactiver les sous niveaux Actionner la touche Reset pendant environ 5 secs jusqu ce que l intensit 0 soit affich e Frequency c 2 seconds 1 Sto wellenintensit t 1 bis 20 Mit den Tasten Sto wellenintensit t v verringern und StoRwellenintensit t erh hen k nnen die Intensit tsstufen eingestellt werden Unterstufen der Intensit t 1 Die Intensit ts Anpassungsstufen 0 0 bis 0 9 erm glichen Einstellungen f r z B schmerzemp findliche sensible Behandlungszonen 2 Einschalten der Unterstufen Die Taste StoRwellenintensitat v
91. ni locali e Neoplasie locali e Disordini della coagulazione necessario conoscere lo stato di coagulazione precedente e Assunzione di farmaci anticoagulanti e Gravidanza e Presenza di tessuti polmonari nella zona da sottoporre alla terapia e Bambini con epifisi aperte Complicazioni Finora non sono state riscontrate complicazioni di tipo pi grave Effetti collaterali Riscontrato l insorgere di Ematomi locali petecchie Irritazioni cutanee locali Edemi locali B STA KUND Tack f r att ni valde denna nya EMS produkt Den uppfyller h gsta kvalitets och s kerhetskrav P t nkt anv ndning EMS Swiss PiezoClast r avsedd att anv ndas f r att avge riktade st tv gor f r behandling av olika indikationer f r det muskuloskeletala systemet F ljande indikationer har med framg ng behandlats med EMS Swiss PiezoClast Triggerpunktbehandling med tryckv gor TPST Indikationer Kroniska sm rtsamma muskul ra sp nningar s k myofasciala triggerpunkter inom omr dena vre extremiteter Skulderg rdel H ftregion Nedre extremiteter Kontraindikationer Lokala infektioner Lokala tum rer Koagulationsst rningar f reg ende koagula tionsstatusunders kning n dv ndig Medicinering med blodf rtunningsmedel Graviditet Lungv vnad i tryckv gsomr det Barn med ppna epifyser Komplikationer Komplikationer av allvarligt tilltagande art har hittills inte konstaterats Biver
92. ni o una diminuzione dell immunit di questo prodotto ELEKTROMAGNETISK KOMPATIBILITET ES Denna produkt kr ver s rskild f rsiktighet avseende elektromagnetisk kompatibilitet och m ste installeras och tas i drift enligt anvis ningarna Elektromagnetisk kompatibilitet ES Vissa typer av mobiltelekommunikations utrustning kan eventuellt st ra denna produkt H nsyn m ste tas till de avst nd som rekom menderas i anvisningarna Elektromagnetisk kompatibilitet N Denna produkt ska inte anv ndas intill eller staplas p annan enhet utom vid stapling p en EMS Swiss DolorClast Sl inte p b da appara terna samtidigt om produkten anv nds intill eller r staplad p en EMS Swiss DolorClast Denna apparat ska vidare alltid h llas under tillsyn f r att kontrollera att den fungerar normalt med den konfigurering som ska anv ndas N Anv ndning av andra tillbeh r och kablar n dem som specificeras eller s ljs av EMS som reservdelar kan resultera i kad emission eller minskad immunitet f r denna produkt 83 TROUBLESHOOTING Status and error messages on the display Status message APPL Err 1 Err 2 Err 3 Err 4 Err 5 Err 6 Err 7 Err 8 Err 9 Err 10 Err 11 Err 12 Shock wave indicator blinks Shock wave indicator End Cause Handpiece is not connected or the connection to the handpiece is disconnected during shock wave triggering Error in high voltage generator Error in high voltage g
93. nsi que des intervalles de maintenance l utilisateur devra se conformer aux dispositions l gales en vigueur dans le pays ou l appareil est utilis Ces interventions peuvent tre effectu es par EMS ou un centre de r paration agr Sicherungen ZN Ersetzen Sie die Sicherung ausschliesslich durch den auf der R ckseite des Ger tes angege benen Sicherungstyp IS Wenn die gesetzlichen Bestimmungen in Ihrem Land k rzere Intervalle vorschreiben so gelten diese ES Um den Standard IEC 60601 1 bez glich technischen und Sicherheitstest sowie Wartungs intervalle zu erf llen muss der Benutzer die Gesetze und Vorschriften in dem Land in dem das Ger t betrieben wird einhalten Diese Wartung kann von EMS oder einem autorisierten Repara turzentrum durchgef hrt werden Fusibles A Reemplazar nicamente por el mismo tipo de fusible indicado en el panel posterior del aparato IS Si las disposiciones legales en su pa s prescriben intervalos m s cortos de manteni miento debe tenerlo en cuenta ES Para cumplir la norma IEC 60601 1 acerca de los ensayos t cnicos y de seguridad as como los intervalos de mantenimiento el usuario debe seguir la legislaci n y reglamentaci n local en el pa s en el que est funcionando el dispositivo Este mantenimiento puede ser realizado por EMS o por un centro de reparaci n autorizado Fusibili N Sostituire unicamente con il tipo di fusibile indicato sul retro d
94. nt pas t correctement effectu s A Contre indication le fonctionnement correct des stimulateurs cardiaques et des d fibrillateurs peut tre perturb par les oscillations ultrasoniques de haute fr quence Nous vous conseillons de ne pas traiter les patients porteurs de stimulateurs cardiaques ou de d fibrillateurs avec ce produit A Pour les patients souffrant d une maladie infectieuse il faut pr voir les mesures suivantes Prot ger les plaies ouvertes avant le traitement de mani re ce qu aucun fluide corporel ne puisse sortir Soumettre l appareil apr s le traitement la d sinfection en observant les instructions du fabricant du d sinfectant utilis viter l mission d ondes de choc sur des organes inclusion d air tels que poumon intestin et bien observer la fen tre d entr e en positionnant le patient de mani re ad quate Les ondes de choc risquent de provoquer des r actions non voulues du coeur A N utilisez le produit que pour les appli cations pr vues Ce mode d emploi doit tre soigneusement tudi avant l utilisation Ceci est galement valable pour tous les quipements pouvant tre utilis s en combinaison avec ce produit Vous viterez ainsi tous risques de blessures et d endommagement de votre produit SICHERHEITSHINWEISE EMS und der Vertreiber dieses Produktes haften nicht f r direkte Sch den und Folgesch den die durch unsachgem ssen Einsatz oder Handhabung dieses Prod
95. ntsprechende Stosswellenfrequenz einstellen Mit niedriger Sto wellenintensit t beginnen und dann langsam entsprechend der Indikation die Intensit t steigern Bei Behandlung gr erer Therapiegebiete ist es vorteilhaft den Fokus nacheinander auf verschiedene Bereiche zu positionieren Fases del tratamiento Tratamiento con ondas de choque Mm No disparar la onda de choque antes de que el foco no se encuentre en la zona apuntada De lo contrario aumenta el riesgo de efectos secundarios Las ondas de choque no se deben disparar si antes no se ha identificado la zona apuntada sin lugar a duda y si no se han evaluado los posibles perjuicios que pudiera causar la trayectoria de la onda de choque en las regiones afectadas Intensidad La intensidad se repone a cero si se pulsan al mismo tiempo ambas teclas Intensity v y Si no se suelta una de las teclas autom ticamente la intensidad se reduce aumenta al valor m nimo m ximo Frecuencia Graduar la frecuencia de pulsos al grado 0 para disparar en r gimen de pulsos individuales Graduar la frecuencia de pulsos al correspondiente grado para disparar en r gimen de pulsos continuos Comenzar el tratamiento con una intensidad baja de ondas de choque aument ndola paulatinamente de acuerdo con la indicaci n Para el tratamiento de zonas de cierto tamafio conviene posicionar el foco sobre distintas regiones una tras la otra Ciclo di trattamento Terapia a
96. o not use any cleaning agents scouring agents or solvents on this device Reprocessing of the foot pedal Mm Danger of electric shock Humidity may enter the foot pedal Do not immerse the foot pedal and the connector in water and do not clean under the tap The foot pedal can be cleaned with a soft cloth moistened with surface disinfectant or alcohol Follow the instructions from the manufacturer of the disinfectant 42 RETRAITEMENT Retraitement de l appareil Mm L humidit risque de p n trer dans l appareil Danger d lectrocution Mettre l appareil hors service et le d brancher du secteur avant de le soumettre au retraitement L appareil peut tre essuy avec un linge imbib de d sinfectant pour surfaces ou d alcool Respecter les instructions du fabricant du d sin fectant AN Veiller ce qu aucune humidit ne puisse p n trer l int rieur de l appareil N utiliser pour l entretien de l appareil ni d tergents ni produits r curer ni solvants Retraitement de la p dale A De l humidit risque de p n trer l int rieur de la p dale Danger d lectrocution Ne jamais immerger la p dale ni le connecteur dans l eau et ne pas les nettoyer sous l eau du robinet La p dale peut tre essuy e avec un linge imbib de d sinfectant pour surfaces ou d alcool Respecter les instructions du fabricant du d sin fectant AUFBEREITUNG Aufbereitung des Ger ts A Feuchtigkeit kann
97. o other medical devices used The equipotential connector of the device can be connected to the potential equalization point of the room using a potential equalization cable INSTALLATION Connexion lectrique 100 240 V AC 50 60 Hz I Pour viter d endommager l appareil v rifiez que sa tension nominale correspond bien la tension secteur de votre cabinet Connectez l appareil uniquement une prise prot g e par un interrupteur diff rentiel protection FI ES Si applicable brancher la prise quipoten tielle aux autres appareils m dicaux utilis s R aliser la compensation du potentiel de l appareil en le raccordant l aide d un conducteur d quipo tentialit a la compensation du potentiel du local INSTALLIEREN Stromanschluss ES Die Nennspannung des Ger tes muss mit der rtlichen Versorgungsspannung berein stimmen Das Ger t kann sonst besch digt werden Schliessen Sie das Ger t nur ber einen Fl Schalter Fehlerstromschutz an ES Verbinden Sie gegebenenfalls den Poten tialausgleichsstecker mit anderen verwendeten medizinischen Ger ten Ein Potentialausgleich des Ger tes kann ber ein Potentialausgleichskabel mit dem Potentialaus gleich des Raumes hergestellt werden INSTALACI N Conexi n a la red el ctrica IS Compruebe que la tensi n nominal coincide con la tensi n de la red de su consulta puesto que de lo contrario el aparato
98. ock wave therapy AD Trigger a shock wave only if the focus is in the target area If this is not observed the incidence of side effects will increase Apply shock waves only if you have clearly identified the target area and if you can assess any impairment or possible negative impact on the areas to be subjected to shock waves i e the region the shock wave is passing through Intensity Press the two shock wave intensity v and buttons simultaneously to reset the intensity to zero If you press and hold one of the buttons the shock wave intensity is automatically adjusted to the minimum or maximum value respectively Frequency For single shock waves set the pulse rate to 0 For continuous shock waves select the corre sponding shock waves rate Start at a low shock wave intensity and then slowly increase the intensity in accordance with the indication When treating larger therapy zones we recommend positioning the focus consecutively at different areas 24 D roulement du traitement Traitement par ondes de choc A Veiller ne d clencher l onde de choc que si le foyer se trouve parfaitement dans la zone traiter En cas d inobservation de possibles effets secondaires peuvent se produire Ne pas appliquer d ondes de choc avant que la zone cibl e ne soit identifi e clairement et avant qu il ne soit exclu qu elles ne risquent pas de nuire aux r gions respectivement travers es Intensit A
99. olta Reset Per impostare un nuovo valore premete il tasto Reset In seguito tutti i valori sono regolati su 0 fino a quando impostato un valore d intensit di onde d urto bloccata la funzione Preselection Preimpostare il numero di onde d urto Azionate lievemente il tasto Preselection fino a raggiungere il numero desiderato di onde d urto In passi da 500 unit possibile preimpostare da un minimo di 500 a un massimo di 4000 onde d urto Per preimpostare il numero di onde d urto il contatore del numero di onde d urto deve essere azzerato Reset Azzerare tutte le preimpostazioni Azionate il tasto Reset F rinst llning av antalet tryckv gor som ska ges Preselection Tryckv gsr knaren visar nedr kningen till O fr n ett f rinst llt antal tryckv gor D refter visas ter f rinst llt antal blinkande Reset St ll in ett nytt antal genom att trycka p Reset varvid alla v rden stalls p 0 sa l nge ett v rde f r tryckv gsintensitet h ller p att st llas in r Preselection sp rrat F rinst llning av antal tryckv gor Tryck p knappen Preselection tills nskat antal tryckv gor uppn tts steg om 500 kan l gst 500 och h gst 4 000 f rinst llas F r att antalet tryckv gor ska kunna f rinst llas m ste tryckv gsr knaren st pa 0 Reset Tryck p knappen Reset f r att terst lla alla f rinst llningar till O 23 Treatment sequence Sh
100. om fuktats med ytdesinfektionsmedel alkohol eller sprit Beakta desinfektionsmedeltill verkarens anvisningar 45 Remove the gel pad from the handpiece Clean the contact surface ofthe handpiece the gel pad and the twist lock ring with warm water under the tap max 30 C then wipe with a disposable cloth and disinfect with surface disinfectant Use only a suitable and approved disinfectants for the gel pads Follow the instructions from the manufacturer of the disinfectant Manufacturer Brand name Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Extra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid 46 Retirer le gel pad de la pi ce a main Nettoyer la surface de contact de la pi ce a main le gel pad et la bague a baionnette sous l eau tiede du robinet 30 C maximum les essuyer ensuite avec un linge a usage unique et les d sinfecter a l aide d un d sinfectant pour surfaces N utiliser pour les gel pads que des produits de d sinfection appropri s et valid s cet effet Observer les instructions du fabricant du d sin fectant Fabricant Nom commercial Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Extra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid Das Gelpad vom Handst ck entfernen Die Kontaktoberfl che des Handst cks das Gelpad und den Bajonettring unter flie endem lauwarmen Wasser max 30 C reinigen danach mit einem Einmaltuch abwischen un
101. omplications have not been observed Side effects Occurrence of Local haematomas petechiae e Local irritation of the skin Local edemas CHERS CLIENTS Nous vous f licitons pour l acquisition de ce nouveau produit EMS Il r pond aux plus hautes exigences en mati re de qualit et de s curit Utilisation pr vue Le Swiss PiezoClast EMS est destin produire des ondes de choc focalis es pour le traitement de diff rentes indications sur l appareil locomoteur Les indications suivantes sont trait es avec succ s avec le Swiss PiezoClast d EMS Traitement des points trigger par ondes de choc TPST Indications Tensions musculaires douloureuses chroniques appel es points trigger dans les r gions suivantes Membres sup rieurs Ceinture scapulaire R gion pelvienne Membres inf rieurs Contre indications Infections locales Tumeurs locales Troubles de la coagulation pr voir une v rifi cation de l tat de la coagulation auparavant Prise de m dicaments anticoagulants Grossesse Pr sence de tissu pulmonaire dans la r gion des ondes de choc Enfant en croissance piphysaire Complications Des complications s v res n ont pas pu tre constat es Effets secondaires Apparition de H matomes locaux p t chies e Irritations locales de la peau CEd mes locaux SEHR GEEHRTE KUNDEN Wir gratulieren Ihnen zum Kauf Ihres neuen EMS Produktes Es erf llt h chste Anspr
102. oque e Informaci n y mensajes de error 4 Indicaci n Frecuencia de pulsos 5 Tecla Aumentar la intensidad de ondas de choque 6 Tecla Reducir la intensidad de ondas de choque 7 Tecla Aumentar la frecuencia de pulsos 8 Tecla Reducir la frecuencia de pulsos 9 Tecla Stand By 10 Testigo de control Stand By 11 Tecla Preselecci n de n mero de ondas de choque 12 Tecla Reset reposici n 13 Tecla Funci n 1 14 Tecla Funci n 2 15 Conector de mango 16 Soporte del mango 17 Conector 18 Pedal de mando 19 Cable de alimentaci n 20 Interruptor de alimentaci n 21 Toma de corriente con porta fusibles 22 Conector de interruptor de pedal 23 Interfaz de datos solo para servicio t cnico 24 Compensaci n de potencial 25 Ventilador 26 Fusibles 27 Botella de gel 28 Almohadilla de gel cambiable 29 Anillo de bayoneta para almohadilla de gel 30 Mango 31 Surtido de almohadillas de gel 32 Juego de fijaci n para el PiezoClast DolorClast 33 Cilindro de prueba completo 34 Soporte del mango de tabla EMS suministra este aparato con diversos accesorios La Lista de contenido indica exactamente lo que in cluye su aparato COMPONENTI AA 00 00014 N Ak GO JO 4 002 x x Apparecchio Display Intensit dell onda d urto Display Conteggio di onde d urto e Informazioni e messaggi d errore Display Frequenza impulso Tasto Aumentare intensit onde
103. ous souhaitez mettre d finitivement au rebut le produit respectez les directives nationales sp cifiques en vigueur dans votre pays Les quipements lectriques et lectroniques en fin de vie appartenant aux clients localis s dans l Union Europ enne peuvent tre envoy s EMS pour tre recycl s en accord avec la directive WEEE Les co ts du recyclage l exclusion des frais de transports sont couverts par EMS GARANTIE Des deg ts li s au non respect du mode d emploi ou l usure des pi ces sont exclus de la garantie IS La garantie de votre produit sera annul e si vous essayez de l ouvrir ACCESSOIRES Vous trouverez les accessoires aupr s d EMS ou de l un des distributeurs autoris s Veuillez contacter votre service client le directement ENTSORGEN DES PRODUKTES Das Produkt darf nicht mit dem normalen Haushaltsm ll entsorgt werden Wollen Sie Ihr Produkt endg ltig entsorgen beachten Sie bitte die jeweils in Ihrem Land geltenden Bestimmungen Abfall aus elektrischen und elektronischen Ger ten im Besitz von Kunden in der Europ i schen Union k nnen gem der WEEE Richtlinie f r die Wiederverwertung an EMS zur ckgegeben werden Die Kosten f r das Recycling exklusive der Kosten f r die Anlieferung werden von EMS bernommen GARANTIE Die durch Nichtbeachten der Bedienungsanleitung und durch Abnutzung entstandenen Sch den an Ger tebestandteilen sind von der Garantie ausgenommen
104. pairs yourself Visual check Check the device and the accessories for damage loose or missing parts hygiene and completeness Check the power cables for damage Any inscriptions lettering or labeling necessary for the safe intended use must be legible Missing inscriptions labeling or identifications leading to wrong handling or reprocessing must be reinstated Check the contact surface of the handpiece for damage Check the handpiece as required by the corre sponding instruction in the chapter Maintenance Function check Connect the handpiece to the unit and switch on the power switch of the device The device runs through a self test If no errors are displayed the Swiss PiezoClast and the connected handpiece are operational 10 UTILISATION DE L APPAREIL Contr les A Proc der aux contr les d crits ci dessous avant et apr s tout emploi Ne plus utiliser de produits qui pr sentent des dommages et ou des pi ces manquantes ou d tach es Renvoyer les produits d fectueux avec les pi ces d tach es pour r paration Ne pas proc der des tentatives de r paration Contr le visuel V rifier que l appareil et les accessoires ne pr sentent ni d fectuosit s ni pi ces d tach es ou manquantes ni encrassement V rifier l tat parfait des cordons d alimentation V rifier que les inscriptions et marquages n ces saires un emploi s r et conforme la destination sont lisibles
105. patibilidad electromagn tica 83 Medidas a adoptar en caso de incidentes 87 Manutenzione in 49 Intervalli di manutenzione Fusibill naaa Verifica dell energia del manipolo 53 Display della versione software 57 Osservazioni sulla sicurezza 59 Conservazione del prodotto 63 Smaltimento del prodotto Garanzia ACCESS ini Servizio assistenza EMS SIMBOLI sus Dati tecnici tse Compatibilit elettromagnetica 83 Misure da adottare in caso d incidente 88 Underhall osorno Underh llsintervall Sakrinigar iii E Kontroll av applikatorns kapakcitet 53 Visning av programvaruversion 57 S kerhetsf reskrifter n 59 F rvaring av produkten 63 Kassering av produkten 65 Garantire aiar 65 Tillbeh r 3 65 EMS Service 67 Symboler 1109 Tekniska data ee a 81 Elektromagnetisk kompatibilitet 83 ESISOKNINO visi tai 89 INSTALLATION Power connection gt To prevent damage to the unit check that its rated voltage corresponds to the local line voltage Use the unit only in a Fl protected mains supply Fl Residual current protection IS When applicable connect the equipotential plug t
106. pressure 700 hPa to 1060 hPa CARACT RISTIQUES TECHNIQUES Description de l appareil Distributeur Fabricant Mod le Classification EN 60601 1 Classification 93 42 CE Tension de l alimentation Fr quence secteur Puissance nominale Niveau sonore Fusibles Mode de travail Poids Dimensions en mm L x x h Conditions de fonctionnement Conditions de stockage et de transport EMS SA CH 1260 Nyon Suisse RICHARD WOLF GmbH 75438 Knittlingen Allemagne Swiss PiezoClast Class I Partie appliqu e du type B IP 20 appareil IP X8 p dale lectrique Mode de fonctionnement service continu Classe IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A T3 15L Mode d impulsions continu Fr quence de r p tition 1 20 Hz environ 14 5 kg environ 30 8 lbs 395 mm x 400 mm x 170 mm 10 C a 35 C 30 75 d humidite relative pression atm de 700 hPa 1060 hPa 5 C 40 C 10 95 d humidit relative pression atm 700 hPa 1060 hPa Description de la pi ce main Distributeur Fabricant Mod le Classification EN 60601 1 Angle d aperture Diam tre d aperture Densit du flux d nergie positive Plage de pression Taille du foyer de min max fx 6dB fy 6dB fz 6dB Volume du foyer Fr quence d impulsion Niveaux d intensit nergie totale E 5 mm Profondeur de p n tration Poids Conditions de fonctionnement Conditions de stockage et de transport
107. puede sufrir desperfectos Conecte el aparato a una toma de corriente protegida por un interruptor diferencial protecci n Fl Conecte el enchufe equipotencial a otros dispositivos m dicos cuando corresponda El conector para la compensaci n del potencial del aparato se puede conectar a la conexi n equipotencial de la sala utilizando un cable equipotencial INSTALLAZIONE Collegamento energia INSTALLATION Anslutning till str mk lla IES La tensione nominale dell apparecchio deve essere corrispondente alla tensione di alimentazione del vostro studio In caso contrario possono verificarsi dei danni all apparecchio Collegare l apparecchio unicamente ad una presa protetta da un interruttore differenziale prote zione Fl IS Dove amp applicabile collegate la spina equipotenziale agli altri dispositivi medicali usati La compensazione del potenziale dell appa recchio pu essere ricavata dalla compensazione del potenziale del locale interessato utilizzando un cavo di compensazione del potenziale ES F r att undvika skador p apparaten kontrollera att dess m rksp nning st mmer med den lokala sp nningen Anslut apparaten till eluttag med jordfelsbrytare ES Anslut i f rekommande fall den ekvipoten tiella kontakten till annan medicinsk apparat som anvands Potentialutj mning f r apparaten kan stad kommas genom att en potentialutj mningskabel kopplas till omgivningen
108. que el campo a tratar sea f cilmente accesible Marcar en la piel la zona l mite del campo a tratar p ej con un rotulador de fieltro Elegir la almohadilla de gel en funci n de la profundidad de penetraci n previamente deter minada La cifra inscrita en la almohadilla de gel A corres ponde a la profundidad de penetraci n E del foco terap utico F en mm vea las Fig 1 y 2 Cuanto m s alto sea la almohadilla de gel tanto menor ser la profundidad de penetraci n E v ase la Fig 1 y 2 Ciclo di trattamento con il manipolo Il paziente deve essere collocato su un lettino per trattamenti o su una sedia La posizione del paziente deve essere stabile Fate in modo di poter accedere facilmente all apparecchio I contorni della zona da sottoporre al trattamento devono essere evidenziati tracciando dei segni sulla pelle del paziente ad esempio con un pennarello Selezionate il gelpad in base alla profondita di penetrazione Il numero sul gelpad A corrisponde alla profondit di penetrazione E del fuoco F in mm veda le Fig 1 e 2 Maggiore amp l altezza del gelpad minore sar la profondit di penetrazione E veda le Fig 1 e 2 Behandlingsf rlopp med handstyck Placera patienten p ett patientbord eller en stol s att patienten befinner sig i en stabil position Se till att terapiomr det r l tt tkomligt Markera f r att avgr nsa behandlingsytan p huden t ex med en filtpenna
109. rapie TPST 37 INAIKAtIGNEn crateri 37 Orthop die ESWT rn 38 Lagerungsbeispiele 38 Empfohlene f r Sto wellen Therapie IS OI E A0 Aufberetung 42 Aufbereitung des Ger ts Aufbereitung des Fu schalters 242 Aufbereitung des Handst cks 44 INDICE Instalaci n ecrire 3 Conexi n a la red el ctrica 140 Suministro del pedal 5 Instrucciones de montaje por el juego de fijaci n para el Swiss PiezoClast opci n 7 Utilizaci n del aparato 11 Te 11 Preparaci n del mango 13 Conexi n del Mango ensanse 17 Graduar la intensidad de las ondas de en leie EE 19 Graduar la frecuencia de pulsos 21 Preseleccionar la suma de ondas de choque que se van a aplicar 23 Fases del tratamiemto ee 25 Pedal vecinita 27 Evaluaci n de la terapia con ondas de 6191010 EE 29 Principio de funcionamiento del mango 31 Fases del tratamiento con el mango 33 Terapia de trigger points por ondas de choque RK De on 37 Indicaciones aao Ortopedia ESWT 209 Posturas recomendadas sssssesersssena 39 Recomendaci n por el tratamiento para ondas de choque ESWT 41 Reprocesamiento 43 Reprocesamiento del equipo
110. rasound gel to the center of the contact surface of the handpiece Put on the gel pad avoiding air bubbles 12 Pr paration de la pi ce main Mise en place du gel pad A N utiliser que les gels de contact qui ont t certifi s pour tre utilis s sur les patients Observer les instructions du fabricant du gel Mise en place du gel pad Appliquer une quantit suffisante de gel chographique au milieu de la surface de contact de la pi ce main Poserle gel pad en vitant toute bulles d air Vorbereiten des Handst cks Gelpad aufsetzen A Nur f r Patientenanwendung zugelassene Ultraschallgels verwenden Die Angaben des Gelherstellers beachten Gelpad aufsetzen Auf die Mitte der Kontaktoberfl che des Handst cks ausreichend Ultraschallgel auftragen Gelpad luftblasenfrei aufsetzen Preparaci n del mango Preparativi del manipolo F rberedelse av handstycke Colocar la almohadilla de gel Come collocare il gelpad Montera gelplattan A Utilice solamente geles para ultrasonido A Utilizzate esclusivamente il gel per A Anv nd endast ultraljudgel till tna f r validados para el empleo en pacientes Observe ultrasuoni autorizzato per l impiego sui pazienti patientbruk Beakta geltillverkarens anvisningar las indicaciones del fabricante del gel Seguite le indicazioni del fabbricante del gel Montera gelplattan Colocar la almohadilla de gel Come collocare il gelpad Applicera tillr ckl
111. rasuoni non fuoriesce attorno al bordo del gelpad Collocate l anello a baionetta e bloccatelo ruotando in senso orario Quando collocate l anello fate attenzione ai punti di marcatura Devono coincidere Come togliere il gelpad Sbloccate l anello a baionetta ruotando in senso antiorario e toglietelo Quando sollevate l anello a baionetta fate attenzione ai punti di marcatura Devono coincidere Togliete il gelpad Verificate il gelpad e il manipolo secondo quanto indicato nel paragrafo Ritrattamento Tryck p gelplattan och vrid den samtidigt l tt fram och tillbaka s att ultraljudgelet tr nger ut litet l ngs kanten av gelplattan Montera bajonettringen och l s den genom att vrida den medurs Var noga med att markeringspunkterna verensst mmer Ta av gelplattan Lossa bajonettringen genom att vrida den moturs och avl gsna den Var noga med att markeringspunkterna st mmer verens n r du tar av ringen Avl gsna gelplattan G r i ordning gelplatta och applikator enligt anvisningarna i avsnitt terbearbetning Connecting the handpiece A Do not use the product if it is damaged or incomplete or has loose parts Return damaged product together with any loose parts for repair Do not attempt to do any repairs yourself A Make sure that the markings on the plug and socket are aligned A Make sure to only connect or disconnect the handpiece connec
112. re attentivement ce mode d emploi car tous les d tails et tous les gestes importants y sont clairement d crits Respectez en particulier les remarques concernant la s curit Veuillez conserver ce document toujours port e de main Se r f rer au manuel d utilisation ce produit n cessite des pr cautions particuli res concernant la compatibilit lectromagn tique Il doit tre install et mis en service selon le manuel Electromagnetic compatibility Pour pr venir des possibles accidents corporels ou dommages au PiezoClast merci de tenir compte des directives suivantes Danger Risque de blessure pour le patient ou l utilisateur Attention Risque de dommage a l appareil ou l environnement Remarques Informations compl mentaires et conseils utiles Interdit Autoris RP ZU DIESEM HANDBUCH Diese Bediendungsanleitung soll Ihnen bei der korrekten Installation und Bedienung des Produkts helfen Lesen Sie sie somit aufmerksam durch da die wesentlichen Einzelheiten und Handgriffe anschaulich erkl rt werden Beachten Sie dabei besonders die Sicherheitshinweise Bewahren Sie diese Unterlagen immer griffbereit auf Gebrauchsanweisung befolgen f r dieses Ger t sind besondere Vorsichtsma nahmen hinsichtlich der elektromagnetischen Kompatibi lit t zu beachten Die Installation und Inbetrieb nahme des Ger ts muss die Anforderungen des Handbuchs f r die Electromagnetic compatibility erf llen
113. rgie de la pi ce main WARTUNG Wartungsintervalle AN Zur Vermeidung von Vorf llen bzw Sch den die durch Alterung und Verschleif des Ger tes sowie des Zubeh rs entstehen k nnen muss die Wartung in angemessenen Abst nden durchgef hrt werden Je nach H ufigkeit der Benutzung jedoch mindestens alle 12 Monate m ssen Funktions und Betriebssicherheit von einem Fachmann gepr ft werden T gliche Kontrollen Das Handst ck und alles Zubeh r auf Besch di gungen lose oder fehlende Teile hygienischen Zustand und Vollst ndigkeit berpr fen Verbindungskabel des Handst cks auf Besch di gungen berpr fen Das Gelpad muss vom Handst ck entfernt sein Kontaktoberfl che des Handst cks Gelpad und Bajonettring m ssen gereinigt und mit Oberfl chendesinfektionsmittel desinfiziert sein Monatliche Kontrollen Aufschriften und Kennzeichnungen die zum sicheren bestimmungsgem ften Gebrauch erfor derlich sind m ssen lesbar sein Fehlende oder nicht mehr lesbare Aufschriften und Kennzeichnungen die zu Fehlern in der Handhabung oder Aufbereitung f hren m ssen wieder hergestellt werden Kontaktfl che des Handst cks auf Besch di gungen berpr fen berpr fung der Handst ckenergie MANTENIMIENTO Intervalos de mantenimiento AN Para evitar incidentes y dafios que pudieran presentarse debido a envejecimiento y desgaste del aparato y de los accesorios ste se debe someter a mantenimiento inc
114. roduit vers un centre de r paration agr EMS indiquer le nom de votre distributeur Cela permet de simplifier le traitement EMS SERVICE Bitte schicken Sie Ihr Produkt f r alle Wartungs oder Reparaturarbeiten an Ihren H ndler oder ein von EMS autorisiertes Reparaturzentrum EMS lehnt jede Haftung hinsichtlich der Sicherheit des Ger ts ab und erkl rt die Garantie ung ltig falls Wartungen und Reparaturen durch nicht autorisierte Personen durchgef hrt wurden oder falls andere als die Original Ersatzteile benutzt wurden Verwenden Sie f r den Transport am besten die Originalverpackung Dadurch ist Ihr Produkt w hrend des Transports gesch tzt A Vor dem Versand m ssen das Ger t und alle Zubeh rteile gem der Bedienungsanleitung gereinigt und desinfiziert werden Bei Direktversand des Produkts an das von EMS autorisierte Reparaturzentrum geben Sie bitte den Namen Ihres H ndlers an Dies erleichtert die Abwicklung SERVICIO T CNICO EMS Si su producto necesitara una revisi n o reparaci n env elo a su distribuidor o a un centro de reparaci n autorizado de EMS EMS declina toda responsabilidad sobre la seguridad del aparato declarando la garant a no v lida si una tercera persona no autorizada realiza una revisi n o reparaci n o si se utilizan piezas de repuesto no originales Lo mejor es enviar el producto en su embalaje original que lo protege de da os durante el transporte A Limpie desi
115. rolli giornalieri Verificate giornalmente se el manipolo e i relativi accessori risultano danneggiati se presentano parti staccate o mancanti Verificatene lo stato di pulizia e la completezza Verificate la presenza di eventuali danni sul tubo flessibile di collegamento al manipolo Verificare se il gelpad amp stato tolto del manipolo Pulite e disinfettate con un disinfettante per superfici la superficie di contatto del manipolo il gelpad e l anello a baionetta Controlli mensili Le scritte e i contrassegni che sono necessari per un impiego sicuro e conforme alle disposizioni devono essere leggibili necessario rifare le scritte e i contrassegni mancanti o non pi leggibili che possono provocare errori nella manipolazione o ritratta mento dell apparecchio Verificate la presenza di eventuali danni sulla superficie di contatto del manipolo Verificate l energia del manipolo UNDERH LL Underh llsintervall A F r att undvika tillbud eller skador som kan uppst p grund av att apparaten och tillbeh ren ldras och f rslits m ste underh ll utf ras med rimliga intervall Beroende p hur ofta appara turen anv nds dock minst var 12 e m nad m ste apparaturens funktions och drifts kerhet kontrol leras av en specialist Dagliga kontroller Kontrollera att applikatorn med tillbeh r inte har n gra skador l sa eller saknade delar som saknas j mte hygieniskt skick och skick i vrigt Kontroll
116. sitetssteg Total energi E 5 mm Penetreringsdjup Vikt Anv ndningsf rh llanden F rvaring och transportf rh llanden EMS SA CH 1260 Nyon Schweiz RICHARD WOLF GmbH 75438 Knittlingen Tyskland Handstycke F10 G4 Swiss PiezoClast Klass Till mpad del Typ B IP 20 94 100 mm 0 03 0 4 mJ mm 11 5 82 2 MPa 1 2 2 8 mm 5 0 14 1 mm 58 mm 1 8 Hz 20 steg 9 54 mJ 5 40 mm ca1 2 kg 10 35 C 30 75 rel luftfuktighet Lufttryck 700 1 060 hPa 5 40 C 10 90 rel luftfuktighet Lufttryck 700 1 060 hPa 81 ELECTROMAGNETIC COMPATIBILITY I This product needs special precautions regarding electromagnetic compatibility and needs to be installed and put into service according to the note Electromagnetic compatibility ES Certain types of mobile telecommunication equipment could potentially interfere with this product The separation distances recommended in the note Electromagnetic compatibility must be taken into account A This product should not be used adjacent to or stacked with another unit except of being stacked to an EMS Swiss DolorClast If the product is used adjacent or stacked to an EMS Swiss DolorClast do not switch on both devices simultaneously In addition this product should always be observed to verify normal operation in the configuration in which it will be used A The use of accessories and cables other than those specified or sold by EMS as replacement parts may res
117. sm rtsamma muskul ra sp nningar s k myofasciala triggerpunkter inom omr dena vre extremiteter Skulderg rdel H ftregion Nedre extremiteter 37 ORTHOPEDICS ESWT Positioning examples Shoulder calcifying tendinitis Positioning Sitting or lying paule tendinosis calcarea Posture assise ou couch e Schulter Tendinosis calcarea Lagerung Sitzend oder liegend Hombro tendinosis calc rea Posici n del paciente sentado o tendido Per la cura della spalla Tendinosi calcarea Posizione del paziente seduto o sdraiato Kalkaxel tendinosis calcarea Placering sittande eller liggande 38 ORTHOP DIE ESWT Postures recommand es Plantar fasciopathy Positioning Lying prone position Fasciite plantaire Posture couch e ventrale Plantarfasziopathie Lagerung Liegend Bauchlage Fascitis plantar Posici n del paciente tendido dec bito abdominal Fascite plantare Posizione del paziente sdraiato a pancia in gi Fasciitis plantar Placering liggande bukl ge ORTHOP DIE ESWT Lagerungsbeispiele Elbow Epicondylitis humeri radialis and ulnaris Positioning Sitting Coude picondylite hum ro radiale et ulnaire Posture assise Ellenbogen Epicondylitis humeri radialis und ulnaris Lagerung Sitzend Codo epicondilitis humeral radial y ulnar Posici n del paciente sentado Gomito Epico
118. sono derivare da uso improprio o errato del prodotto in particolare dall inosservanza delle istruzioni d uso o da preparazioni o manutenzione non idonei A Controindicazioni le oscillazioni ad ultrasuoni possono impedire il funzionamento corretto di elettrostimolatori cardiaci e di defibril latori Pertanto consigliamo di non trattare con questo prodotto i pazienti portatori di stimolatori cardiaci o defibrillatori A Nei pazienti con malattie infettive neces sario adottare le seguenti precauzioni Prima di effettuare il trattamento proteggete le ferite scoperte in maniera tale che non fuoriescano liquidi corporali Dopo il trattamento disinfettate l appa recchio Seguite le indicazioni del fabbricante del disinfettante Evitate gli onde d urto su organi all interno dei quali presente dell aria esempio polmoni intestino Fate attenzione alla direzione di entrata dell apparecchio e o posizionate il paziente di conseguenza Gli onde d urto possono provocare reazioni cardiache indesiderate A Utilizzate il prodotto soltanto per le applica zioni previste Queste istruzioni per l uso devono essere accuratamente studiate e comprese prima dell utilizzo del prodotto Questo anche valido per tutti i prodotti che possono essere utilizzati in combinazione con questo apparecchio Eviterete cos qualsiasi rischio di ferimento e di danno del vostro prodotto S KERHETSF RESKRIFTER EMS och distribut ren av denna produ
119. tal des ondes de choc de la pi ce main Actionner la touche de Fonction F2 et Intensit Le total d ondes de choc affich est celui des ondes de choc mises par la pi ce main branch e sur l appareil Statistique du total des ondes de choc de l appareil Actionner la touche de Fonction F2 et Intensit v Le total d ondes de choc affich est celui des ondes de choc mises par l appareil Exemple L affichage correspond 31476 ondes de choc Auswertung der Sto wellentherapie Mittelwert der Sto wellenintensit t Die durchschnittliche Sto wellenintensit t pro Behandlung wird bei Bet tigen der Taste Funktion F1 angezeigt Die Anzeige der Sto wellen Statistik wird durch Bet tigen der Taste Reset auf Null gesetzt Die Anzeige der StoRwellen Statistik wird automatisch nach dem Aus und wieder Einschalten des Ger tes auf Null gesetzt Gesamt Sto wellenstatistik der Therapiequelle Taste Funktion F2 und Sto wellenintensit t bet tigen Es wird die Summe der abgegebenen Sto wellen des am Ger t angeschlossenen Handst cks angezeigt Gesamt Sto wellenstatistik des Ger tes Taste Funktion F2 und Sto wellenintensit t v bet tigen Es wird die Summe der abgegebenen Sto wellen des Ger tes angezeigt Beispiel Die Anzeige entspricht 31476 StoRwellen Evaluaci n de la terapia con ondas de choque Intensidad media de las ondas de choque La intensidad media de
120. tella Spitzensyndrom 3 6 Shock wave frequency Hz 4 6 4 6 4 4 6 4 6 4 6 Frequence des ondes de chocs Hz 4 6 4 6 4 4 6 4 6 Sto wellenfrequenz Hz 4 6 4 6 4 4 6 4 6 4 6 Number of shock waves 2000 1500 2000 1500 2000 2000 2000 2000 2500 Nombre d ondes de chocs 2000 1500 2000 1500 2000 2000 2000 2000 2500 Anzahl der Sto wellen 2000 1500 2000 1500 2000 2000 2000 2000 2500 Number of sessions 3 Ww Go Nombre de s ances Anzahl der Sitzungen Wo wi wo Recomendaci n por el tratamiento para ondas de choque ESWT Mm Un n mero excesivo de disparos puede causar lesiones tisulares No aplique m s ondas de choque que el n mero se alado en las instrucciones Indicaci n Tendinosis calc rea Epicondilitis humeral radial Epicondilitis humeral ulnar Tend n de Aquiles aquilodinia Fascitis plantar S ndrome patelo femoral Indicazioni per la terapia ad onde d urto ESWT Mm Se il numero di impulsi pressori troppo elevato Possibili danni ai tessuti Per ogni trattamento non applicate un numero di onde d urto che supera quello indicato nelle istruzioni Indicazioni Tendinosis calcarea Epicondilite dell omero radiale Epicondilite dell omero ulnare Tallone di Achille achillodinia Fascite plantare Sindrome dell apice patellare Intensidad 6 10 3 6 3 6 4 6 6 10 3 6 Intensit 6 10 3
121. tlingen Germany Swiss PiezoClast Class I Applied part Type B IP 20 unit IP X8 electrical foot pedal Mode continuous operation Class IIb 100 127 220 240 VAC 50 60 Hz 150 VA 65 dB A T3 15L Multiple pulse mode repetition rate 1 20 Hz approx 14 5 kg approx 30 8 Ibs 395 mm x 400 mm x 170 mm 10 C to 35 C 30 to 75 relative humidity atmospheric pressure 700 hPa to 1060 hPa 5 C to 40 C 10 to 90 relative humidity 700 hPa to 1060 hPa air pressure atmospheric pressure 700 hPa to 1060 hPa Description of the handpiece Distributor Manufacturer Model Classification EN 60601 1 Aperture angle Aperture diameter Energy flux density positive Pressure range Focal size min to max fx 6dB fy 6dB fz 6dB Focal volume Pulse frequency Intensity stages Overall energy E 5 mm Penetration depth Weight Operating conditions Storage and transport conditions EMS SA CH 1260 Nyon Switzerland RICHARD WOLF GmbH 75438 Knittlingen Germany Handpiece F10 G4 for Swiss PiezoClast Class Applied part Type B IP 20 94 100 mm 0 03 to 0 4 mJ mm 11 5 to 82 2 MPa 1 2 to 2 8 mm 5 0 to 14 1 mm 58 mm 1 to 8 Hz 20 steps 9 54 mJ 5 to 40 mm approx 1 2 kg approx 2 7 Ibs 10 C to 35 C 30 to 75 relative humidity atmospheric pressure 700 hPa to 1060 hPa 5 C to 40 C 10 to 90 relative humidity 700 hPa to 1060 hPa air pressure atmospheric
122. tor when the device is switched off 16 Connexion de la pi ce main Aufstecken des Handst cks A Ne plus utiliser de produits qui pr sentent des dommages et ou des pi ces manquantes ou d tach es Renvoyer les produits d fectueux avec les pi ces d tach es pour r paration Ne pas proc der des tentatives de r paration Veiller ce que le rep re du connecteur et celui de la prise co ncident Il ne faut pas connecter ou retirer le connecteur de la pi ce main avant que l appareil ne soit teint A Produkte die besch digt oder unvoll st ndig sind bzw lose Teile aufweisen nicht mehr verwenden Besch digte Produkte mit den losen Teilen zur Reparatur einsenden Keine eigenen Reparatur versuche vornehmen Darauf achten dass die Markierung am Stecker und an der Buchse bereinstimmen Der Stecker des Handst cks darf nur bei ausgeschaltetem Ger t herausgezogen bzw eingesteckt werden Conexi n del mango A No vuelva a utilizar los productos deterio rados incompletos o con piezas sueltas Env e los productos deteriorados junto con las piezas sueltas para reparaci n Abst ngase de repararlos A Cuidar de que la marca en el enchufe coincida con la marca en el conector A Antes de sacar o enchufar el enchufe del mango se ha de desconectar el aparato Connessione del manipolo A Non utilizzate pi prodotti danneggiati incompleti o che present
123. tra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid Avlagsna gelplattan fran applikatorn Reng r applikatorns kontaktyta gelplattan och bajonettringen under rinnande ljummet vatten max 30 C och torka d refter av dem med en eng ngshandduk och desinficera med ytdesin fektionsmedel Till gelplattorna f r endast anv ndas h rf r avsedda och godk nda desinfektionsmedel Beakta desinfektionsmedeltillverkarens anvis ningar Tillverkare Produktnamn Bode Bacillol Bacillol AF Braun Meliseptol Ecolab Incidin Extra N Merz Pursept A Sch lke amp Mayr Antifect N Liquid 47 MAINTENANCE Maintenance intervals AN To avoid any incidents or damage caused by aging and wear it is necessary to service the product and the accessories at adequate intervals Depending on the frequency of use but at least once a year have an expert check the functional and operational safety of the equipment Daily checks Check the handpiece and the accessories for damage loose or missing parts hygienic condition and completeness Check the connection cable of the handpiece for possible damage The gel pad must be removed from the handpiece The contact surface of the handpiece the gel pad and the twist lock ring must be cleaned and disinfected using a surface disinfectant Monthly checks Any lettering labeling or identification necessary for the safe intended use must be legible Missing or illegible lettering label
124. uenza d impulso Pulsfrekvens Aumentar el valor Aumento del valore impostato H j v rdet Reducir el valor Diminuzione del valore impostato S nk v rdet Conexi n para el mango Connessione per il manipolo Anslutning av handenhet 71 72 F 1 F2 C 012 Function 1 button Touche de Fonction 1 Taste Funktion 1 Function 2 button Touche de Fonction 2 Taste Funktion 2 CE marking Refers to directive 93 42 EC including EN 60601 1 and EN 60601 1 2 Marquage de conformit CE Se rapporte la directive 93 42 CE y compris EN 60601 1 et EN 60601 1 2 CE Kennzeichen Bezieht sich auf die Richtlinie 93 42 EWG einschlieBlich EN 60601 1 und EN 60601 1 2 Disposal of old electrical amp electronic equipment applicable in the European Union and other European countries with separate collection systems Traitement des appareils lectriques et lectroniques en fin de vie applicable dans les pays de l Union Europ enne et aux autres pays europ ens disposant de syst mes de collecte s lective Entsorgung von Abfall aus elektrischen und elektronischen Ger ten f r die Europ ische Union und andere europ ische L nder ohne separates Entsorgungssystem Equipotential earth Terre quipotentielle Potentialausgleich Erde F 1 F2 C 012 Tecla Funci n 1 Tasto Funzione 1 Funktionsknapp 1 Tecla Funci n 2 Tasto Funzione 2 Funktionsknapp 2 Marcaci n de conformidad CE Hace referenc
125. uire la fr quence verringern und Stosswellenfrequenz 4 wave frequency d impulsions et augmenter la fr quence erh hen kann die gew nschte Stosswellenfre d impulsions quenz eingestellt werden 20 Graduar la frecuencia de pulsos Regolare la frequenza d impulso Inst llning av pulsfrekvens La frecuencia de pulsos deseada se puede selec Potete regolare la frequenza d impulso desiderata Med knapparna v minska resp ka cionar con las teclas v reducir y aumentar con il tasti di frequenza d impulso v diminuire pulsfrekvensen kan nskad pulsfrekvens st llas e aumentare in 21 Presetting the total number of shock waves to be applied Preselection The shock wave counter counts down to 0 starting from a preset number of shock waves Then the preset value is displayed again blinking Reset To set a new value press Reset which resets all values to 0 as long as a value is set under shock wave intensity Preselection is inhibited Presetting the shock waves Keep actuating the Preselection button until the required number of shock waves is reached In steps of 500 a minimum of 500 and a maximum of 4 000 shock waves can be preset For presetting the shock waves the shock wave counter must be on 0 Reset Resetting all presettings to 0 Press the Reset button 22 Pr s lection du nombre total d ondes de choc appliquer Pr s lection Le compte
126. uktes auftreten insbesondere durch Nichtbeachtung der Bedienungsanleitung oder durch unsachgem sse Vorbereitung oder Wartung A Kontraindikationen Herzschrittmacher und Defibrillatoren k nnen durch Ultraschallschwin gungen in ihrer Funktion gest rt werden Daher empfehlen wir Patienten mit Herzschrittmachern oder Defibrillatoren nicht mit diesem Produkt zu behandeln A Bei Patienten mit infekti sen Krankheiten m ssen folgende Ma nahmen durchgef hrt werden Vor der Behandlung offene Wunden so abkleben dass keine K rperfl ssigkeiten austreten Nach der Behandlung das Ger t desinfi zieren Die Angaben des Desinfektionsmittel herstellers beachten A Abgabe von Sto wellen auf Organe mit Lufteinschl ssen z B Lunge Darm vermeiden Auf Eintrittsrichtung des Handst cks achten bzw Patient entsprechend lagern StoRwellen k nnen unerw nschte Herzaktionen verursachen A Nur f r den vorgesehenen Verwendungs zweck einsetzen Diese Bedienungsanleitung ist vor dem Einsatz sorgf ltig zu lesen und zu verstehen Dies gilt gleichermassen f r alle in Kombination mit diesem Ger t eingesetzten Produkte Auf diese Weise vermeiden Sie Verlet zungen sowie Besch digungen an Ihrem Produkt PRECAUCIONES DE SEGURIDAD EMS y los distribuidores de este producto no se hacen responsables de los da os directos e indirectos derivados del uso o manipulaci n incorrectos de este producto especialmente por la no observaci n d
127. ult in increased emissions or decreased immunity of this product 82 COMPATIBILIT ELECTROMAGNETIQUE RSP Ce produit n cessite des pr cautions particulieres concernant la compatibilit lectro magn tique Il doit tre install et mis en service selon la notice Compatibilit Electromagn tique RSP Certains types d appareils mobiles de t l communication sont susceptibles d interf rer avec ce produit Les distances de s paration recommand es dans la notice Compatibilit lectromagn tique doivent tre respect es A Ce produit ne doit pas tre utilis a proximit d un autre appareil ou empil sur ce dernier except l empilement avec le Swiss DolorClast d EMS Si l appareil est utilis proximit d un Swiss DolorClast ne pas mettre sous tension les deux appareils en m me temps En plus il est imp ratif avant l utilisation de v rifier son bon fonctionnement dans les conditions d utilisation AN Putilisation d accessoires ou de c bles autres que ceux sp cifi s ou vendus par EMS comme pi ces de remplacement peut avoir comme cons quence une augmentation de l mission ou une diminution de l immunit de ce produit ELEKTROMAGNETISCHE VERTR GLICHKEIT ES F r dieses Produkt sind im Bereich der elektromagnetischen Vertr glichkeit spezielle Vorsichtsmassnahmen erforderlich Es muss daher in bereinstimmung mit der Anweisung Elektromagnetische Vertr glichkeit installiert und in Betrie
128. ur des ondes de choc d compte partir du nombre total des ondes de choc pr s lectionn jusqu 0 La valeur pr s lectionn e clignote encore une fois Reset Pour r gler une autre valeur appuyer sur Reset pour remettre les valeurs 0 tant qu une valeur d intensit des ondes de choc est r gl e Prese lection reste bloqu Pr s lectionner les ondes de choc Appuyer sur le bouton Preselection autant de fois qu il est n cessaire pour arriver au nombre d ondes de chocs souhait Par palier de 500 un minimum de 500 et un maximum de 4000 ondes de chocs peut tre choisi Pour pouvoir pr s lectionner les ondes de choc le compteur d ondes de choc doit tre r gl 0 Reset Remettre toutes les valeurs pr s lectionn es o Actionner la touche Reset Voreinstellung der Anzahl der zu applizierenden Sto wellen Vorwahl Der Sto wellenz hler z hlt eine voreingestellte Anzahl von Sto wellen abw rts bis 0 Danach wird der voreingestellte Wert nochmals blinkend angezeigt Reset Um einen neuen Wert einzustellen Reset dr cken dann werden alle Werte auf 0 gestellt solange ein Wert bei der Sto wellenintensit t eingestellt ist wird Preselection gesperrt Anzahl der Sto wellen voreinstellen Die Taste Preselection so oft bet tigen bis die gew nschte Sto wellenanzahl erreicht ist In 500 er Schritten k nnen minimal 500 und maximal 4000 StoRwellen
129. ut en godkand applikator Tryck pa funktionsknapp F2 blinkandet stangs av Blinkandet kan inte l ngre st ngas av Anslut en ny applikator N om felet inte kan avhj lpas med ledning av denna tabell kontakta v r serviceavdelning eller skicka oss apparaten f r reparation F reta inga egna reparationsf rs k Driftfel Apparaten fungerar inte Ingen tryckv g M jlig orsak Atgard Str mbrytaren inte paslagen N tkabeln inte ansluten Anslut n tkabeln Ingen n tsp nning finns Kontrollera n tsp nningen N ts kringen defekt Byt n ts kring Sl till str mbrytaren Fotkontakten inte isatt defekt S tt i fotkontakten byt fotkontakt 89
130. velli Azionate per circa 2 secondi il tasto d intensit dell onda d urto v diminuire fino a quando il display dell intensit dell onda d urto non indica il valore 0 0 Potete regolare l intensit dell onda d urto da 0 0 a 0 9 3 Disinserimento dei sottilivelli Azionate per circa 2 secondo il tasto Reset fino a quando il display dell intensit dell onda d urto non indica il valore O Inst llning av tryckv gsintensitet ei 2 seconds 1 Tryckv gsintensitet 1 20 Med knapparna v minska resp 6ka tryck v gsintensiteten kan intensitetsstegen st llas in L gre intensitetsniv n 1 Intensitetsanpassningsstegen 0 0 0 9 m jligg r inst llningar f r t ex sm rtk nsliga k nsliga behandlingszoner 2 Inkoppling av l gre niv er Tryck under ca tv sekunder p knappen v minska tryckv gsintensitet tills displayen visar tryckv gsintensitet 0 0 Tryckv gsintensiteten kan nu st llas in mellan 0 0 och 0 9 3 Urkoppling av l gre niv er Tryck i ca tv sekunder in knappen Reset tills displayen visar tryckv gsintensitet 0 Setting the shock wave frequency R glage de la fr quence d impulsions Stosswellenfrequenz einstellen The shock wave frequency v reduce and Le niveau de la fr quence d impulsion peut tre Mit den Tasten Stosswellenfrequenz v increase buttons serve to set the required shock r gl a l aide des touches v r d
131. verringern ca 2 Sekunden bet tigen bis die Anzeige Sto wel lenintensit t 0 0 anzeigt Die Sto wellenintensit t kann zwischen 0 0 und 0 9 eingestellt werden 3 Ausschalten der Unterstufen Die Taste Reset ca 2 Sekunden bet tigen bis die Anzeige Sto wellenintensit t 0 anzeigt Graduar la intensidad de las ondas de choque Regolare l intensit dell onda d urto SWISS PIEZOCLAST Preselection Reset 1 Niveles de intensidad de ondas de choque de 1 a 20 Los niveles de intensidad se pueden graduar con las teclas v reducir y aumentar Subniveles del nivel de intensidad 1 Los niveles de intensidad de 0 0 a 0 9 permiten un ajuste de precisi n por ejemplo en zonas de tratamiento sensibles al dolor 2 Activar los subniveles Pulsar unos dos segundos la tecla v reducir hasta que la intensidad indicada sea de 0 0 La intensidad de las ondas de choque se puede graduar entre 0 0 y 0 9 3 Desactivar los subniveles Pulsar unos dos segundos la tecla Reset hasta que la intensidad indicada sea de 0 1 Intensit dell onda d urto da 1 a 20 Potete regolare il livello d intensit dell onda d urto con i tasti v diminuire e aumentare Sottolivelli d intensit 1 I livelli di adattamento dell intensit da 0 0 a 0 9 consentono delle regolazioni per zone di tratta mento particolarmente sensibili al dolore 2 Inserimento dei sottili
132. voreingestellt werden Zur Sto wellen Voreinstellung muss der StoRwel lenz hler auf 0 stehen Reset Alle Voreinstellung auf 0 zur cksetzen Die Taste Reset bet tigen Preseleccionar la suma de ondas de choque que se van a aplicar Preselection El contador de ondas de choque realiza una cuenta atr s hasta 0 de un n mero predeter minado de pulsos de onda de choque A continuaci n el valor preseleccionado vuelve a aparecer parpadeando Reset A fin de ajustar un nuevo valor pulsar Reset para reponer todos los valores a 0 la funci n Preselection queda bloqueada mientras que est ajustado un valor referente a la intensidad de las ondas de choque Preseleccionar el n mero de ondas de choque Pulsar la tecla Preselection tantas veces como sea necesario para llegar al n mero de ondas de choque deseado En pasos de cada vez 500 ondas de choque se puede seleccionar un m nimo de 500 y un m ximo de 4000 ondas de choque Para realizar la preselecci n de las ondas de choque el contador de ondas de choque debe estar en 0 Reset Reponer a 0 todos los ajustes realizados Pulsar la tecla Reset Preimpostazione dell insieme di onde d urto da applicare Preselection Il contatore del numero di onde d urto conteggia un numero preimpostato di impulsi di onde d urto in ordine discendente fino a 0 In seguito il valore preimpostato amp visualizzato lampeggiante ancora una v
Download Pdf Manuals
Related Search
Related Contents
Samsung HW-H355 Керівництво користувача Manuale d`uso e manutenzione MICROMASTER 411 & COMBIMASTER 411 Tecumseh RKA5450YXG Performance Data Sheet A710X & A711X Installation and Operating Instructions University Program Design Laboratory Package Verde LED VER-CF50-750 Copyright © All rights reserved.
Failed to retrieve file