1. Bedienungsanleitung Operating Instructions Elektronisches Vorschaltger t Electronic Ballast EB 4000 Universal 115 230 V Briese 1200 2500 4000 W flicker free Briese Lichttechnik Vertriebs GmbH Hamburg Germany 49 40 780908 0 mail info briese lichttechnik de web www briese lichttechnik de INHALT Seite 1 Allgemeine Hinweise 2 022002402000000000 000 nenn ann anne nnn ann nnn nennen nenn 3 2 Wichtige Sicherheitshinweise cccccccecceeceeeeeeeeceeeceeseeeeeeeaeeeaees 3 3 PFOQUUKIHESCHFEIDUNG eccriene rss eE EEEE EE E EEEE Gi 5 4 ImbettieDnanme des EVG aussen sense 7 4 1 Einschalten des EVG nannten une 7 4 2 Einstellung der Lichtintensit t u2z0024022002nenne nennen T 4 3 Ger uschminderung ccccecceecceeeceeeceeeceeaueceeeseeeceeeseeeseeeaes 8 9 POCMIMISCH CD ANC een 9 OFON 6 6 9 gt ea ae ee ere 10 7 Anschlu belegung 220022002400en0nenennnennnnnnnnnnenenennnennn nennen 18 8 Anordnung der Bedienelemente 002002400000en0nnn nennen 19 Contents Page Tt General FREI Wo een ee ee 11 2 Important Safety Instructions 00220022002n0nenenenennnennnnenen nenn 11 ol FOGUGE DOSED WON en ee ee ee 13 FATU Procedi nennen 14 4 1 Energizing SY SUC IN sssncces neeeasnnacnonscopessasesesanasanasaneannneaensasanneascaness 14 4 2 Control of Light Intensity cee eecceeeceeeceeea
2. Dispose of packing material properly Do not place the ballast into operation if damages are apparent To assure safe operation use EB only according to the information given in these operating instructions connect and operate it as shown on the serial number plate In case of malfunction disconnect the EB from mains pull out the line plug Repairs exchange of replacement parts and manipulations on the EB must be carried out by a qualified personnel or service only Use only original spare parts for repairs Use only original accessories Make worn out Electronic Ballasts inoperable immediately by pulling out the line plug and cutting the line cable at the ballast Then dispose of the Electronic Ballast properly Make sure that children do not operate the EB Always switch off the EB and pull out line plug before you clean it or do maintenance work on it Clean EB dry only or with a moist cloth Never immerse it into water Do not use the connection cables of the EB for carrying do not pull them over sharp edges clamp them under doors or clamp them in any other way e Switch off EB when it is not needed The EB 4000 Universal is part of an optimized lighting system along with luminaires specified for operation with the EB see fig 1 page 18 It is suitable for both professional indoor and outdoor use IP21 protection
3. Note The Electronic Ballast EB 4000 Universal meets the European Council Directive 89 336 EEC of electromagnetic compatibility Over an extensive range limits of radio disturbance characteristic B are fulfilled But on principle it has to be classified under characteristic A group 1 Although limits of radio disturbance characteristic A are prescribed for industrial areas administrative authority can allow the use of equipment with characteristic A in other than industrial areas Compared to magnetic ballasts there are a number of advantages when operating daylight lamps with Electronic Ballasts Flicker free light No synchronization of cameras necessary Typical lightripple max 3 Light intensity increased by at least 5 Constant lamp power Constant color temperature Constant light quality Control of electric power of the lamp between 50 100 Variation in power supply voltage of 10 has no influence on the power of the lamp see also Technical Data for limits on page 16 Variation in power supply frequency of 10 has no influence on the power of the lamp Operating life time of the lamp increased by at least 20 Substantially less volume and weight compared to magnetic ballasts e The ballast is built in to a casing with type of protection IP21 13 4 Start up procedure English All operating controls and cable connect
4. itself may be faulty or at the end of its life The thermal cut out in the ballast may have activated due to extreme ambient temperature or exposure to direct sunlight in hot summer conditions LED TEMP on front plate is lit The ventilation might be restricted In such a case the ballast can be used after it had cooled down and the condition causing the overheating is removed If the power supply exceeds the limits or has spikes or drop outs the ballast switches off to protect itself If running on a generator the output should be regulated between 195 245V If a ballast has cut off due to a momentary supply drop out switch the ballast OFF and ON again The ballast should start up as normal Earth leakage of luminaires or head to ballast cables will also cause the protection circuit to be activated Test the ballast with a known good luminaire If cables are suspect they should be exchanged with known good cables If a ballast is found to be faulty ideally it should be returned together with the luminaire and head to ballast cable to the service location for examination ae Spannungsversorgung Power Supply Han Q 4 2 190 250 V 50 60Hz N 4 kW Freigabe 4 kW Enable offen open max 2500 W geschlossen closed max 4000 W Elektronisches Vorschaltgerat Electronic Ballast EB 4000 Universal Rechteck wandler Square Wave Converter Zu
5. nicht z ndet ist m glicherweise die UV Sicherheitsschleife durch den Scheinwerfer unterbrochen Wenn die gr ne Safety LED auf der Frontplatte des EVG nicht leuchtet l t sich das EVG nicht einschalten Es ist zu pr fen ob alle Schalter der UV Scherheitsschleife des Scheinwerfer geschlossen sind 6 6 Ist dass EVG an einer stabilen und ausreichend bemessenen Netzversorgung angeschlossen 6 7 Ist der Sicherungsautomat am EVG eingeschaltet 6 8 Wenn die Kombination Vorschaltger t Verl ngerungskabel Leuchte nicht startet kann der Fehler in jeder der drei Einheiten vorliegen Eine verd chtige Leuchte sollte nicht mit einem anderen EVG erneut gestartet werden andernfalls k nnten zwei zerst rte EVG das Ergebnis sein Um zu Pr fen ob ein EVG funktionst chtig ist ist eine gepr fte Leuchte direkt ohne Verlangerungskabel an das EVG zu schalten 6 9 Wenn das EVG nach einigen Minuten abschaltet k nnen verschiedene Ursachen vorliegen Die Lampe selbst kann fehlerhaft sein oder das Ende ihrer Lebensdauer erreicht haben Die Thermoschalter im EVG k nnten aktiviert sein weil die Umgebungs temperatur zu hoch ist oder das EVG direkter Sonnenbestrahlung in hei er Umgebung ausgesetzt wurde LED TEMP auf der Frontplatte leuchtet Auch k nnte der freie Zu und Ablauf der K hlluft im EVG verhindert sein In diesen F llen kann das EVG nach Abk hlung und Beseitigung der Ursache f r die berhitzung wieder gestart
6. as Ger t ber den Ein Ausschalter bedient werden Die Fernsteuerung des Ger tes erfolgt ber zwei DMX Kan le Der erste Kanal dient der Dimmung der zweite auf der n chsth heren Adresse gelegene schaltet das Ger t ein bzw aus Die LED Anzeige an der Ger tefront zeigt die Adresse des Dimmkanales an ber den Dimmkanal kann durch Senden von Werten im Bereich 127 bis 255 die Lampenleistung linear zwischen 50 und 100 der Nennleistung eingestellt werden ber den Schaltkanal wird das Ger t durch Senden von O 127 ausgeschaltet eingeschaltet wird es durch Senden des Wertes 128 255 Wird das Ger t ber die Fernbedienung eingeschaltet ist das Dimm Potentiometer auf der Frontplatte des EVG au er Funktion Achtung Das Potential der Fernsteuersignale an den Buchsen DMX IN und DMX OUT darf nicht mehr als 70 Volt Spitzenspannung gegen ber Schutzleiter annehmen 4 5 Einstellung der Ger teadresse Im oberen Bereich der Frontplatte zeigt eine LED Anzeige die DMX Adresse des Dimmkanales des Ger tes an Mit den Tasten UP aufw rts und DOWN abw rts kann die angezeigte Adresse ver ndert werden Mit der Taste Enter kann dem Ger t die angezeigte Adresse innerhalb von zwei Sekunden zugewiesen werden Die gr ne LED DMX zeigt an da auf der eingestellten DMX Adresse und der darauffolgenden Schaltadresse Signale empfangen werden 8 5 Technische Daten Netzanschlu Eingangsleistung Netzspannun
7. ation of DIN EN 60598 1 and DIN EN 60065 for electrical appliances 2 6 Supply voltage must not exceed the ranges that are given in the Technical Data see page 16 Check that the power supply voltage and wiring are suitable for the ballast to be used Supply voltages which are greater or less than that specified for the ballast can cause injury to the user as well as damage to the ballast The electronic of the EB is built in a housing with protective class and protective rate IP 21 Ambient operating temperatures must be between 20 C and 50 C Neither heat sinks nor air slots for ventilation should ever be covered or obstructed The EB must be placed only on solid flat and dry ground Temperature of the ground should be less than 50 C If the EB could slip over the ground it must be fastened Protect EB against direct sunshine Protection against rain is needed when wind pushes water drops direct into the air slots of the EB acc to protective rate IP 21 Do not operate the EB in high humidity dew or in aggressive or explosive gas air mixtures 11 English 2 7 The Electronic Ballast must be used only according to the directions in this Operating Instruction The manufacturer shall not be liable for any damages caused by unintended use or wrong operation 12 3 Product Description English 2 8 The user of the Electronic Ballast is urgently requested to observe the following instructions
8. die auf die besondere Betriebsweise zur ckzuf hren sind Der Low Noise Schalter erlaubt drei verschiedene Betriebsweisen des EVG 1 In der Stellung 300 Hz blaue LED arbeitet das EVG im flacker freien Modus mit 300 Hz Ausgangsfrequenz Die Metalldampflampe strahlt gleichf rmiges Licht aus Diese Betriebsart ist daf r optimiert bei der Benutzung von Filmkameras mit hohen Filmgeschwindigkeiten hochaufl sende Bilder zu erzielen 2 In der Stellung Flicker Free gr ne LED arbeitet das EVG im flacker freien Modus mit 75 Hz Ausgangsfrequenz Die Metalldampflampe strahlt gleichf rmiges Licht aus 3 In der Stellung 60 Hz rote LED arbeitet das EVG im low noise Modus Das Ger usch in der Leuchte ist stark reduziert Das Licht ist jetzt nicht mehr flackerfrei In dieser Betriebsweise gilt die gleiche Einschr nkung f r die Filmgeschwindigkeit wie sie auch beim Drosselbetrieb mit 60Hz 30 fps Netzfrequenz G ltigkeit hat Alle anderen Vorteile der Elektronischen Vorschaltger te bleiben jedoch erhalten Hinweis Mit dem Hand Me ger t P R O F kann im Zweifelsfall die Flackerfreiheit bzw Frequenz des Lichtes direkt innerhalb weniger Sekunden berpr ft werden 4 4 DMX Fernsteuerung Soll das Ger t ber die Fernsteuerung betrieben werden mu der Ein Ausschalter an der Ger tefront ausgeschaltet sein Ist kein Fernsteuersignal vorhanden oder wird auf dem Fernsteuerkanal AUS Pegel 0 127 empfangen kann d
9. eeeeeeeeeeseeees 14 4 3 Reduction of Lamp Noise cccccecceecceeteeeeeeteeeeeeseeteeeeeeees 14 9 CHIANG AN Dali nenne 16 6 Trouble Shooting Guide 0222022002200nn0 nenn nnnennnennnennnennnnnnn 17 7 Connector Wiring u2zu02000200ennnennnnnnennnennnennnnnnnnnnnnnennnennn nennen 18 8 Operating Parts on Front Panel u2220222022002000nnn nenne 19 20 12 07 Deutsch English BEDIENUNGSANLEITUNG Elektronisches Vorschaltgerat EB 4000 Universal 1 Allgemeine Hinweise Vor der ersten Inbetriebnahme des Elektronischen Vorschaltgerates EB 4000 2 Wichtige Sicherheitshinweise Universal EVG sind alle im folgenden aufgefuhrten Informationen aufmerksam durchzulesen Sie enthalten wichtige Hinweise fur die Sicherheit den Gebrauch und die Wartung des Ger tes Die Gebrauchsanweisung ist sorgf ltig aufzubewahren und an eventuelle Nachbesitzer weiterzugeben 2 1 Vorsicht Netzspannung Lebensgefahr Vor dem ffnen des EVG ist das Ger t vom Netz zu trennen Netzstecker ziehen Nicht am Anschlu kabel sondern am Stecker ziehen um das Ger t vom Netz zu trennen Reparaturen sowie der Anschlu eines anderen Netzsteckers siehe 2 2 d rfen nur durch eingewiesenes Fachpersonal oder vom Service durchgef hrt werden 2 2 Vor dem Anschlie en des Vorschaltger tes an das Netz sind die Netzsteckdosen auf die Einhaltung der Schutzma nahmen zu pr fen Bei spannungsf hrende
10. elassenen Spannungsbereich siehe technische Daten auf S 9 haben keinen Einflu auf die Lichtstabilitat nderungen der Netzfrequenz bis max 10 bleiben ebenso ohne Einflu auf das Licht Brennerlebensdauer um 20 h her e Geringeres Volumen und Gewicht gegen ber DVG S mtliche Bedienelemente und Kabelverbindungen sind auf der Frontplatte angeordnet siehe Abb 2 Seite 19 4 1 Einschaltvorgang Pr fen ob sich der ON OFF Schalter in der O Stellung befindet Gepr fte Leuchte siehe Abb 1 Seite 18 an das EVG anschlie en Die Ausgangsleistung des EVG wird an die Nennleistung der verwendeten Leuchte 1200 W oder 2500 W 4000 W automatisch angepa t EVG ans Netz anschlie en Das EVG wird mit verschiedenen Netzkabeln ausgeliefert Zum Betrieb von 1200 W und 2500 W Leuchten kann wahlweise das 16 A Netzkabel Schuko Stecker oder das 32 A Netzkabel CEE Stecker verwendet werden Die 4000 W Leuchte kann aufgrund der h heren Anschlu leistung nur mit dem 32 A Netzkabel betrieben werden Eine 4000 W Leuchte l t sich mit dem 16 A Netzkabel zwar starten die Ausgangsleistung wird aber auf 2500 W begrenzt Pr fen ob der Netzautomat eingeschaltet ist Die gr ne LED POWER auf der Frontplatte leuchtet wenn Netzspannung anliegt und der Netzautomat eingeschaltet ist Schutzleiteranschlu berpr fen Bei korrektem Schutzleiteranschlu leuchtet die gr ne LED PE auf der Frontplatte Be
11. et werden Dar ber hinaus kann sich das EVG zum Schutz vor Zerst rung abschalten wenn die Netzspannung zu hoch zu niedrig oder mit Spannungsspitzen berlagert ist Beim Generatorbetrieb sollte die Generatorspannung zwischen 195 V und 245 V geregelt sein Schaltet das EVG durch einen kurzzeitigen Netzausfall ab gen gt das Aus und Wiedereinschalten des EVG um die Lampe erneut zu starten Defekte in der Leuchte wie z B ein Erdschlu k nnen ebenso zur Abschaltung f hren In diesem Fall ist das EVG mit einer gepr ften Leuchte zu testen Wenn ein Verlangerungskabel defekt erscheint ist es unbedingt durch ein gepr ftes Kabel auszutauschen Wenn ein EVG ausgefallen ist sollte es idealerweise zusammen mit Verl ngerungskabel und Leuchte vom Service gepr ft werden 10 English OPERATING INSTRUCTIONS Electronic Ballast EB 4000 Universal 1 General Remarks 2 Important Safety Instructions Please read the following operating instructions very carefully before using the Electronic Ballast EB the first time They contain important information and instructions for the safety use and maintenance of the appliance For your own safety please follow all safety instructions and warnings Keep the operating instructions carefully in a safe place and pass them to any future Owner 2 1 Warning High voltages inside ballast Danger to life Disconnect EB from power supply before openi
12. eter Dimming Potentiometer Low Noise Schalter Low Noise Switch Sicherungsautomat Main Circuit Breaker
13. g Netzstrom Leistungsfaktor Lampenanschlu Lampenleistung 4650 VA max 190 250 V 50 60 Hz 1 N PE 4000 W 25 19A 2500 W 15 12 A 1200 W 7 4 5 6 A cos 0 98 1200 W 2500 W 4000 W konstant geregelt Stromverlauf Rechteckstrom 300 Hz im 300 Hz Modus Rechteckstrom 75 Hz im Flicker Free Modus Abgerundete Rechteckform 60 Hz im 60 Hz Modus Dimmung Bereich 50 bis 100 des Nennwertes der Lampenleistung Zundung Hei und Kaltstart Lichtrippel typ lt 3 Abmessungen B H T 243 358 450 mm Gewicht ca 17 5 kg Umgebungsbedingungen Temperatur 20 bis 50 C Luftfeuchtigkeit 10 bis 80 nicht kondensierend Schutzart IP 21 Fernsteuerung DMX 512 Standard Kanal 1 Dimmung 50 100 Adresse einstellbar Kanal 2 Gerat Ein Aus auf der nach Kanal 1 folgenden Adresse Pinbelegung PIN 1 Ground PIN 2 DMX PIN 3 DMX PIN 4 frei PIN 5 frei 6 Storungssuche 6 1 Wird das EVG mit der richtigen Netzspannung versorgt Der zulassige Bereich ist auf dem Typenschild vermerkt EVG fur mehrere Netzspannungsbereiche schalten automatisch um 6 2 Ist das EVG mit der richtigen Leistungsklasse an den Scheinwerfer angeschlossen 6 3 EVG ans Netz anschlie en und den Schutzleiteranschlu am Vorschaltger t pr fen 6 4 Scheinwerfer an das ausgeschaltete EVG anschlie en Dann ON OFF Schalter einschalten WARTEN Nach ungef hr 5 Sekunden sollte die Lampe starten 6 5 Wenn die Lampe
14. h 3 In the position 60 Hz red LED indicating light the EB is running in low noise mode The noise will be substantially reduced The light however is NOT flicker free any more When operating in this mode the same limitations for speed of camera and or shutter angle apply as for magnetic ballasts operated at 60 Hz mains All other advantages of the electronic ballast will apply as before If in doubt i e remote from ballast with the flicker analyzer P R O F light can be checked to be flicker free or not 4 4 Remote Control DMX 512 Switching the Ballast on off and dimming of lamp power can be controlled by a remote control according DMX 512 standard One channel is used for dimming the ballast the second channel is used for switching the ballast on and off The address of the dimming channel is indicated by the LED display at the front plate of the ballast The address for the on off channel will be the dimming address incremented by one To switch the ballast on a value between 128 and 255 must be send to this address A value of 0 127 will cause the ballast switching off Dimming is done by sending a value between 127 and 255 to the dimming address which will correspond to lamp power regulated between 50 127 to 100 255 of the nominal value To control the ballast via remote it is necessary that it was switched on by remote In this case the dimming potentiometer on front plate of the ballast has no functio
15. i nicht korrektem Schutzleiteranschlu EVG sofort vom Netz trennen Netzstecker ziehen Die gr ne LED Safety auf der Frontplatte leuchtet wenn eine Leuchte mit geschlossener UV Sicherheitsschleife an das EVG angeschlossen ist Wenn die Safety Led nicht leuchtet l t sich das EVG nicht einschalten ON OFF Schalter am EVG einschalten Die Lampe startet nach ca 3 Sekunden Bei Verwendung einer 2500 4000 W Leuchte wird die Nennleistung der eingesetzten Lampe 2500 W oder 4000 W vom EVG elektronisch erkannt Das EVG startet dazu zun chst im 2500 W Modus W hrend der ersten drei Minuten nach dem Z nden der Lampe ist die elektronische Lampenerkennung aktiv Wird eine 4000 W Lampe erkannt schaltet das EVG in den 4000 W Modus Nach Ablauf der dreimin tigen Erkennungszeit wird die Nennleistung bis zum Ausschalten des EVG fixiert o Die gelbe LED LAMP auf der Frontplatte leuchtet wenn die Z ndung der Lampe erfolgreich war 4 2 Einstellung der Lichtintensit t Die Lichtintensit t der warmgelaufenen Metalldampflampe kann durch Drehen des Dimm Potentiometers ver ndert werden Dabei wird die elektrische Lampenleistung zwischen 50 und 100 des Nennwertes eingestellt linker Poti Anschlag min rechter Anschlag max Leistung 4 3 Gerauschminderung Beim flackerfreien Betrieb der Leuchten k nnen in der Leuchte unerw nschte Ger usche entstehen
16. ial ordnungsgem entsorgen Ein Ger t das Schaden aufweist nicht in Betrieb nehmen Zur Gew hrleistung eines sicheren Betriebes Ger t nur nach den Vorgaben in der Bedienungsanleitung einsetzen und gem Typenschildangaben anschlie en und betreiben Im Fehlerfall Ger t vom Netz trennen Netzstecker ziehen Nicht am Anschlu kabel sondern am Stecker ziehen um das Ger t vom Netz zu trennen Reparaturen Ersatzteilaustausch und Eingriffe in das Ger t nur von einer f r diese EVG geschulten Fachkraft oder vom Service ausf hren lassen F r Reparaturen d rfen nur original Ersatzteile verwendet werden Ausgediente Ger te sofort unbrauchbar machen dazu Netzstecker ziehen und anschlie end Anschlu leitung am EVG durchtrennen Danach das Ger t einer ordnungsgem en Entsorgung zuf hren Kindern die Benutzung von EVG untersagen Ger t nur trocken oder mit feuchtem Tuch reinigen Vorher Netzstecker ziehen EVG niemals in Wasser tauchen Anschlu kabel oder Leuchtenkabel nicht zum Tragen benutzen nicht ber scharfe Kanten ziehen nicht unter T ren quetschen oder anderweitig einklemmen Ger t ausschalten wenn es nicht ben tigt wird Ger t nur unter den in der Bedienungsanleitung vorgegebenen Umgebungsbedingungen betreiben 3 Produktbeschreibung Das Elektronische Vorschaltger t EB 4000 Universal bildet eine Fun
17. ions are arranged on the front panel see fig 2 page 19 4 1 Energizing System Check ON OFF Switch to be in O position Connect the properly checked daylight luminaire with head to ballast cable to electronic ballast The output power of the electronic ballast is automatically adjusted to fit the nominal power of the luminaire 1200 W resp 2500 W 4000 W Connect the electronic ballast to the power supply source The EB is delivered with different mains cables For operation of 1200 W and 2500 W lamps either the 16 A cable Schuko plug or the 32 A cable CEE plug can be used Due to the higher apparent power a 4000 W lamp can only be operated by use of the 32 A cable With the 16 A cable the 4000 W lamp can be started but output power is limited to 2500 W Ensure main circuit breaker is in ON position The green LED POWER on front plate is lit when Line Voltage is applied and the Main Circuit Breaker is in ON position Check earth protection If correct the green LED PE on front plate illuminates If not disconnect EB from mains pull out line plug and check power supply and socket Ref 2 2 on page 11 The green LED Safety on front plate is lit when the UV safety loop of the connected luminaire is closed As long as the Safety LED is off the ballast cannot be switched on Set ON OFF switch of the EB to I position Lamp will ignite after about 3 sec When u
18. ktionseinheit mit den f r das EVG zugelassenen Tageslichtscheinwerfer siehe Abb 1 Seite 18 Es ist f r die professionelle Anwendung sowohl in Geb uden als auch f r den Betrieb im Freien geeignet Schutzklasse IP 21 Schutz gegen Tropfwasser Hinweis Das elektronische Vorschaltger t EB 4000 Universal entspricht den geltenden EMV Vorschriften DIN EN 55011 Es erf llt in weiten Bereichen die Grenzwerte der Klasse B ist aber grunds tzlich unter Klasse A Gruppe 1 einzustufen Anmerkung Obwohl die Grenzwerte der Klasse A f r industrielle und kommerzielle Betriebsr ume abgeleitet werden d rfen die Verwaltungen das Errichten und den Betrieb von Ger ten der Klasse A mit allen dazugeh rigen Ma nahmen auch im Wohnbereich oder in solchen Betrieben erlauben die direkt an ein ffentliches Niederspannungsnetz angeschlossen sind DIN EN 55011 Beim Einsatz von Elektronischen Vorschaltger ten EVG f r Metalldampflampen ergeben sich eine Reihe von Vorteilen gegen ber den bisherigen Drosselvorschaltger ten DVG Flickerfreies Licht Keine Kamerasynchronisation erforderlich Typischer Lichteinbruch 3 Lichtausbeute um ca 5 erh ht Konstante Brennerleistung Gleichbleibende Farbtemperatur _5 Stabile optimale Farbqualitat des Lichtes 4 Inbetriebnahme des EVG Einstellung der elektrischen Leistung zwischen 50 und 100 Netzspannungsschwankungen im zug
19. m Schutzleiter darf die Steckdose unter keinen Umst nden benutzt werden Bei fehlendem Schutzleiter ist entweder auf eine ordnungsgem e Steckdose auszuweichen ein Trenntrafo zu benutzen ein Fl Schutzschalter oder ein Anschlu kasten mit Fl Schutzschalter 30mA Erdanschlu und Me einrichtung zu verwenden Hinweis Zur Verhinderung von unbeabsichtigten Ausl sungen durch Ableitstr me und vor bergehende St rungen mu darauf geachtet werden da die Summe der Ableitstr me der Betriebsmittel auf der Lastseite einer RCD FI Schutzschalter weniger als 1 3 des Bemessungsausl sestromes betr gt Der typische Ableitstrom dieses Ger tes betr gt 3 4 mA gem EN 60598 1 1996 Anhang G 2 3 F r den Lampenwechsel einer an das Vorschaltger t angeschlossenen Leuchte ist das Vorschaltger t auszuschalten und die Leuchte elektrisch vom Vorschaltger t zu trennen Leuchtensteckverbinder 2 4 Vor dem L sen bzw Anschlie en des Lampenkabels an der Lampensteck verbindung ist das Ger t auszuschalten Es d rfen nur original Lampenkabel mit f r die Lampenleistung zugelassenem Querschnitt zum Anschlu der Leuchte an das Vorschaltger t verwendet werden Der Betrieb von Leuchten anderer Hersteller als angegeben siehe Abb 1 Seite 18 ist am Vorschaltger t nicht zul ssig 2 5 Das Elektronische Vorschaltger t EB 4000 Universal entspricht den anerkannten Regeln der Technik und den einschl gigen Sicherheitsbestimmungen DIN EN60598 1 u
20. n Attention The potential of the remote control signals at the connectors may not exceed 70 Volts peak against protective earth 4 5 Selection of Device Address At the upper part of the front panel is a LED Display which indicates the current address of the ballasts dimming channel The O up and O down keys can be used to change the displayed address To take over the new address the ENTER key has to be pressed within two seconds The green LED Signal indicates that DMX signals are received at the adjusted channel dimming and at the next channel switching 15 5 Technical Data Mains supply Line Power Supply Voltage Nominal Current Power Factor Lamp connection Lamp Power Current Characteristic Dimming Starting typical light ripple Dimensions width height depth Weight Environmental Ambient Temperature Relative Humidity Protective Rate Remote Control enetisn iE LD 4650 VA max 190 250 V 50 60 Hz 1 N PE 4000W 25 19A 2500W 15 12A 1200W 7 4 56A cos 0 98 1200W 2500 W 4000 W constant control square wave 300 Hz in 300 Hz Mode square wave 75 Hz in Flicker Free Mode nearly square wave 60 Hz in 60 Hz Mode Range 50 100 of nominal Lamp power cold start and hot restrike typ lt 3 243 358 450 mm appr 17 5 kg 20 to 50 C 10 to 80 not condensing IP 21 Accordi
21. nd DIN EN 60065 f r Elektroger te 2 6 Das Ger t ist in ein Geh use der Schutzart IP 21 tropfwassergesch tzt eingebaut Die in den technischen Daten siehe Seite 9 und auf dem Typenschild angegebenen Grenzwerte f r die Netzspannung m ssen unbedingt eingehalten werden Die zul ssige Umgebungstemperatur liegt im Bereich 20 C bis 50 C Beide Seitenw nde des Geh uses sind als Au enk hler ausgef hrt Diese Au enk hler d rfen nicht abgedeckt werden und die L ftungsschlitze in der R ckwand m ssen frei sein Das Vorschaltger t darf nur auf festem ebenem trockenem und nicht hei em Untergrund Temperatur L 50 C aufgestellt werden Bei Rutschgefahr Ger t zus tzlich gegen Verrutschen sichern In Weiterhin mu das Ger t gegen direkte Sonneneinstrahlung gesch tzt werden Ein Regenschutz ist erforderlich wenn die Beanspruchung des Vorschaltger tes durch Spr hwasser ber dem durch IP 21 vorgegebenen Rahmen liegt Das EVG darf nicht im betauten Zustand und nicht in aggressiven oder explosiven Medien eingeschaltet werden 2 7 Das Vorschaltger t darf nur gem den in der Bedienungsanleitung beschriebenen Betriebsbedingungen eingesetzt werden Der Hersteller haftet nicht f r evtl Sch den die durch nicht bestimmungsgem en Gebrauch oder falsche Bedienung verursacht werden 2 8 Der Benutzer dieses Ger tes wird dringend aufgefordert die nachfolgenden Hinweise zu beachten Verpackungsmater
22. ndzeit begrenzer 0 75s Ignition Time Limiter Funktions steuerung Function Control Abb Fig 1 Ausgangsbelegung Lampe Output wiring lamp lamp Funktion Steckerbelegung Function Connector wiring EB 4000 CIRO20FR 24A24S or compatible Lampe Hi Lamp Hi Lampe Lo Lamp Lo Zundgerat Igniter 330 VDC Durch schleifung Safety Loop L fterversorg Fan Supply Kodierung 2 5 4 Interlok 2 5 4 1 Netz Fokus Mains Focus N frei not used Schutzleiter Protective Earth Anschlu belegung Connector Wiring 18 Briese HMI 1200 2500 4000 W Zundgerat Igniter UV Sicherheitsschalter UV Safety Switch L fter Fan 24 VDC max 3 6 W offen open 1200 W geschlossen closed 2500 4000 W Netzsversorgung Focusmotor Mains Supply Focus Motor TAEI DMxX Adressanzeige DMX Address Display EIN AUS Schalter ON OFF Switch LED Anzeige LED Indication Lampensteck verbinder Lamp Connector Netzkabel Mains Cable A 2 e LAMP 8 ON OFF DMX OUT DMX IN OUTPUT O Lamp 300 HON Teve e O POWER 60 Hz type sal 1 2k 2 5k 4 0k i ori 0 3512500088 mains 1 N PE 50 voltage gt 2505 1180 250 V 4 ax rot cl A eA S ef e 5 Abb Fig 2 Bedienelemente auf der Frontplatte Operating Parts on Front Panel 19 DMX Steckverbinder DMX Connectors Dimm potentiom
23. ng pull out the line plug Do not pull on the connection cable but on the plug to disconnect the EB from mains Any repairs or changing of the line plug must only be carried out by qualified personnel or service departments 2 2 Before connecting the Electronic Ballast ensure that the power supply is correctly wired Do not use without adequate earth connection unless either an isolation transformer or an earth leakage trip is employed Note In order to avoid unwanted tripping due to leaking currents and transient disturbances care shall be taken that the collective leakage current of equipment on the load side of a residual current device is less than 1 3 of its rated residual current The typical leakage current of this device is 3 4 mA according EN 60598 1 1996 appendix G 2 3 Lamphead must be disconnected from Electronic Ballast or Electronic Ballast must be disconnected from mains before fitting or replacing a lamp 2 4 The Electronic Ballast must be switched off before connecting or disconnecting either head or supply cable Do not use other than original cables and connector with permitted cross section of the leads The ballast is only suitable for specified luminaires see fig 1 page 18 Using other than original cables or luminaires may cause injury to the user as well and or damage to the ballast 2 5 The Electronic Ballast satisfies the standards of the recognized state of the engineering and the pertinent safety regul
24. ng DMX 512 standard Channel 1 Channel 2 Connector Wiring PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 Dimming Address selectable LED Display shows current Address Device on off Dimming address incremented by one Ground DMX DMX n C n C 16 6 Trouble Shooting Guide English 6 1 Does supply voltage correspond with ballast required voltage Dual voltage ballasts are autoswitching 6 2 Ensure ballast wattage matches lamp power 6 3 Ensure correct lamp is fitted 6 4 Connect ballast to power supply and test earth 6 5 Re energizing system Ensure ON OFF Switch is in O position Switch ON OFF switch to I Switch should now illuminate WAIT After approx 5 seconds lamp should ignite 6 6 If lamp does not strike the UV safety circuit in the lamphead may be broken As long as the Safety LED is off the ballast cannot be switched on Check if all safety switches are closed 6 7 Is there a good power supply to the ballast 6 8 Is the ballast main circuit breaker in ON position 6 9 If a ballast head to ballast cable luminaire does not work then all three units should be considered faulty Do not try a suspected luminaire with another ballast you may end up with two faulty ballasts To check if a ballast is good run it with a known good luminaire without additional extension cables 6 10 If ballast cuts out after running a few minutes there are a number of possible failures The lamp
25. sing a 2500 W or 4000 W lamp the nominal lamp power is detected automatically by electronic lamp detection circuit inside the EB The EB is always starting in 2500 W mode The electronic lamp detection is active for the first three minutes after ignition As soon as a 4000 W lamp is detected the ballast switches over to 4000 W mode After expiration of the three minute detection period the nominal power is fixed until the ballast is switched off The yellow LED LAMP on front plate is lit after successful ignition 4 2 Control of light intensity After warming up the light intensity of the metal halide daylight lamp may be controlled by the dimming potentiometer stepless The nominal lamp power can be adjusted between 50 100 left stop MIN right stop MAX of power 4 3 Reduction of lamp noise When metal halide daylight lamps are operated with electronic ballasts some noise might occur due to the special square wave operation of the lamp 1 In the position 300 Hz blue LED indicating light the electronic ballast operates the lamp flicker free with 300 Hz output frequency The lamp gives out a constant light This mode is specially designated to achieve high resolution pictures when using cameras with high frame rates In the position flicker free green LED indicating light the electronic ballast operates the lamp flicker free with 75 Hz output frequency The lamp gives out a constant light 14 Englis

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 32" D4000  GUÍA DEL USUARIO PREPARACIÓN FUNCIONAMIENTO  デウォルト電動工具 取扱説明書 DC900K 36V充電式 振動/ドリル  PioneerPOS Dash 32GB Grey  iColor 300 series User Manual  TC-2000  N055712 man recip saw DW303 etc NA.indd  solicitud electrónica de ayudas - Oficina Española de Patentes y  4224 CE_Manual EN DE FR_20090828.DOC  Dataram DTM65536B memory module  