Home

WXP 120

image

Contents

1. T005 44 721 99 O Modell Beschreibung Model Description XT KN 60 Lotspitze 60 tip bulk XT GW Lotspitze Chisel XT O Rundform Round chisel XT BS Rundform Round chisel XT CS Rundform Round chisel XT DS Rundform Round chisel XT F 30 Rundf abgeschr Soldering Tips Breite A DickeB Lange C Width A Length B Length C 2 0 mm 0 078 in 2 3 mm 3 2 mm 0 091 in 0 126 in 01 0 mm 0 039 in 2 4 mm 0 095 in 3 2 mm 0 126 in 5 0 mm 0 197 in 01 2 mm 30 Round sloped chisel 0 047 in XT Adapter M4 XT Adapter M5 XT D45 45 Solar Lotspitze 45 Solar chisel 5 0 mm 0 197 in Soldering Tips Bestell Nr Modell Beschreibung Breite A DickeB L nge C Order No Model Description Width A Length B Length C T005 44 722 99 XT Messspitze 5 0 mm 2 XT Measuring tip 0 197 in 1 i E
2. Dadurch sind auch die Isoliereigenschaften des Kunststoffes vermindert F hren Sie keine Arbeiten an unter Spannung stehenden Teilen aus Tragen Sie bei L t oder Entl tanwendungen immer einen Augenschutz Lesen und beachten Sie die Betriebsanleitung der jeweiligen verwendeten Weller WX Versorgungseinheit Legen Sie hei e L t oder Entl tspitzen weder auf die Arbeitsfl che oder auf Kunststofffl chen noch lassen Sie sie dort zur ck Benetzen Sie beim ersten Aufheizen des Kolbens die verzinnten L t Entl tspitzen mit Lot wodurch lagerbedingte Oxidschichten oder Unreinheiten von den L t bzw Entl tspitzen entfernt werden Vergewissern Sie sich dass bei Arbeitsunterbrechungen zwischen L ten und Entl ten sowie vor der Lagerung des Ger tes die L t Entl tspitzen gut benetzt sind Verwenden Sie keine aggressiven Flussmittel Immer darauf achten dass die L t Entl tspitzen ordnungsgem sitzen W hlen Sie die m glichst geringste Arbeitstemperatur W hlen Sie die m glichst gr te L t Entl tspitzenform f r die Anwendung ca so gro wie das L tpad Benetzen Sie die L t Entl tspitzen gut um effiziente W rme bertragung zwischen L t Entl tspitzen und L tpunkt zu gew hrleisten Schalten Sie das System ab wenn Sie das L t Entl twerkzeug ber l ngere Zeit nicht verwenden m chten Benetzen Sie die Spitzen vor Ablegen des L t Entl twerkzeugs in der Sicherheitsablage Geben Sie das Lot dir
3. ALL IMPLIED WARRANTIES APPLICABLE TO THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR FITNESS FOR A PARTICULAR PURPOSE IS LIMITED TO 12 MONTHS FROM THE DATE OF PURCHASE BY THE USER Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Subject to technical alterations and amendments Updated operating instructions are available for download at www weller eu WXP 120 Manual de uso ES WXP 120 WXP 120 Componentes principales del aparato WDH 10 O 1 Limpiador 4 LED de estado 2 Punta de soldadura 5 Cable de silicona antiest tico y termorresistente 3 Empu adura de la punta 6 Clavija de conexi n con mecanismo de bloqueo WXP 120 3 8 Indice 1 Acerca de estas instrucciones cccccssseceesseeesceseeeesseneeeees 3 2 Acerca de la seguridad i isaac iatacul asa soc bal ian ial aaa baia 3 3 Piezas suministradas eee eee eee eee eee eeeeaeee 5 4 Descripci n del aparato eee eee eee eee 5 5 Puesta en servicio del aparato eee 6 6 Cambio de las puntas de soldadura WXP 120 7 F PCCCSONOS tri i
4. DE PEWA Messtechnik GmbH HE WA Weidenweg 21 WXP 1 2 0 58239 Schwerte Tel 02304 961 09 0 Fax 02304 96109 88 Kes E Mail info pewa de Elektronik Homepage www pewa de Betriebsanleitung WXP 120 WXP 120 Gerateubersicht WXP 120 2 OD 4 O WDH 10 O 1 Reinigungseinsatz 4 LED Statusanzeige 2 Lotspitze 5 Temperaturbest ndige antistatische Silikonleitung 3 Spitzengriff 6 Veriegelbarer Anschlu stecker WXP 120 3 8 Inhaltsverzeichnis 1 Zu dieser Anleitung uk 3 2 ZU Arer SICHESHNGM caw doves es 3 A sad pa ba art c ei ii aa i sa alia ada 5 4 Ger tebeschreibung uk eee nennen nennen en 5 5 Inbetriebnahme des Ger tes c eee eee eee 6 6 Wechsel der WXP 120 L oteptzen eee 6 Ce Le nn en T 8 EMISOFQUING carnada 7 E A A IA 8 1 Zu dieser Anleitung Wir danken Ihnen fur das mit dem Kauf des Weller Lotkolbens WXP 120 erwiesene Vertrauen Bei der Fertigung wurden strengste Qualitatsanforderungen zugrunde gelegt die eine einwandfreie Funktion des Gerates sicherstellen Diese Anleitung enthalt wichtige Informationen um den Lotkolben WXP 120 sicher und sachgerecht in Betrieb zu nehmen Zu bedienen zu warten und einfache Storungen selbst zu beseitigen gt Lesen Sie diese Anleitung und die beiliegenden Sicherheitshinweise vor Inbetriebnahme des Lotkolbens WXP 120 durch gt Bewahren Sie diese Anleitung so auf dass sie f r alle Benutzer zug nglich ist 1 1 Einz
5. as junto con la punta de soldadura en el elemento calefactor y apretarlo gir ndolo hacia la derecha 6 Encender la unidad de alimentaci n y ajustar la temperatura deseada 7 Accesorios 7 1 Puntas de soldadura XT para el lapiz de soldadura WXP 120 Ver la tabla de puntas de soldadura XT para l piz de soldadura WXP 120 al final de este manual y en www weller eu 7 2 Piezas de repuesto y accesorios para el WXP120 N pedido Descripcion T0052920199 Lapiz de soldadura WXP 120 T0051512199 Soporte de seguridad WDH 10 T0051384199 Lana de acero para util limpiador WDC 2 8 Eliminaci n de residuos Eliminar las piezas sustituidas del equipo filtros u otros aparatos antiguos seg n las normas y regulaciones aplicables en el pa s correspondiente 9 Garant a Las reclamaciones por parte del comprador en cuanto a defectos f sicos se limitan a un periodo de un a o a partir de la fecha de entrega al comprador Solo v lido para los derechos del comprador seg n el art 88 478 479 BGB c digo civil alem n Nosotros asumiremos solo aquellas reclamaciones relacionadas con la garant a que hemos concedido siempre y cuando la garant a de calidad y durabilidad haya sido concedida de forma escrita y con menci n expresa del t rmino Garantia Reservado el derecho a realizar modificaciones t cnicas Encontrar los manuales de instrucciones actualizados en www weller eu Soldering Tips XT Spitzen fur WP 120 Sol
6. ce Thanks to its slim line design and the extremely short distance from the handle to the tip this soldering iron can be used for general purposes from precision soldering to high temperature soldering The WXP 120 is equipped with a usage detector and can be automatically switched to standby mode or switched off when not in use The operating status is indicated by the status indicator LED For directions for setting the standby temperature and the switching times please refer to the operating instructions of the WX supply unit in use Note The WXP 120 soldering iron by Weller may only be operated together with Weller WX supply units Z LU 6 8 WARNING WARNING WXP 120 4 2 Technical data Temperature range Tool cable Heating element Temperature sensor Heating output Voltage heater Heat up time Connection Weight Tip type Supply unit 100 C 450 C 212 F 850 F Silicone rubber heat resistant Integrated heating wire element Platinum sensor 120 W 24V approx 14s 50 C to 380 C 120 F to 660 F 6 pin connector polarity protected with lock 42 g incl cordless tip XT series Weller WX stations 5 Commissioning the device Risk of burns The soldering tips of soldering irons become very hot during soldering and desoldering processes There is a risk of burns from touching the tips gt Do not touch the hot soldering tips and keep them away from inflammable objects 1 Care
7. dering Tips for WP 120 36 35 61 6 p 3 2 IZ N 2 7 92 4 gt 3 2 ca o a om Q a ro fe f Bestell Nr Order No T005 44 701 99 T005 44 702 99 T005 44 703 99 T005 44 704 99 T005 44 705 99 T005 44 706 99 T005 44 707 99 T005 44 708 99 T005 44 709 99 T005 44 710 99 Modell Model XT AL XT M XTA XT B XTC XT D XT E XT AA XT BB XT CC Beschreibung Description Meisselform Chisel Meisselform Chisel Meisselform Chisel Meisselform Chisel Meisselform Chisel Meisselform Chisel Meisselform Chisel 60 Lotspitze 60 tip bulk 45 Lotspitze 45 tip bulk 45 Lotspitze 45 tip bulk Breite A DickeB Lange C Width A LengthB Length C 1 6 mm 10mm 39mm 0 063 in 0 039 in 1 535 in 3 2 mm 12mm 39mm 0 126 in 0 047 in 1 535 in 1 6 mm 0 zmm 36mm 0 063 in 0 028 in 1 420 in 2 4 mm 08mm 35mm 0 094 in 0 031 in 1 377 in 3 2 mm 08mm 35mm 0 126 in 0 031 in 1 377 in 4 6 mm 08mm 34 5 mm 0 18 in 0 031 in 1 358 in 5 9 mm 12mm 345mm 0 232 in 0 047 in 1 358 in 1 6 mm 0 063 in 2 4 mm 0 094 in 3 2 mm 0 126 in Bestell Nr Order No T005 44 711 99 lt T005 44 712 99 A gt rem T005 44 714 99 _ 1005 44 715 99 T005 44 716 99 PR T005 44 717 99 Q A nz Q T005 44 718 99 T005 44 719 99 O T005 44 720 99
8. e XT Estaciones Weller WX 5 Puesta en servicio del aparato Riesgo de quemaduras Las puntas del lapiz de soldadura alcanzan temperaturas muy elevadas durante los trabajos de soldadura desoldadura Existe riesgo de quemaduras al tocar las puntas de soldadura desoldadura gt No toque las puntas de soldadura calientes y mant ngalas siempre alejadas de objetos inflamables 1 Desembalar con cuidado el l piz de soldadura WXP 120 2 Colocar el l piz de soldadura en el soporte de seguridad WDH 10 3 Insertar la clavija de conexi n 6 en la unidad de alimentaci n corriente y bloquearla gir ndola en sentido horario 4 Comprobar si la tensi n de la red coincide con los datos de la placa de identificaci n de la unidad de alimentaci n WX 5 Encender la unidad de alimentaci n y ajustar la temperatura deseada 6 Una vez que la herramienta ha alcanzado la temperatura deseada el LED de estado 4 se ilumina de forma permanente Esta ar la punta de soldadura WXP 120 jADVERTENCIA Nota 7 8 6 Cambio de las puntas de soldadura WXP 120 Riesgo de quemaduras La punta de soldadura alcanza temperaturas muy elevadas durante la soldadura y desoldadura Existe riesgo de quemaduras al tocar la punta de soldadura gt La herramienta de soldadura debe permanecer desconectada en el soporte de seguridad WDH 10 por lo menos durante 3 min para que la punta de soldadura se enfr e El LED de estado 4 deb
9. e estar apagado Las puntas de soldadura solo se deben cambiar cuando est n fr as Extracci n de la punta antigua 1 2 3 Colocar la herramienta de soldadura en el soporte de seguridad WDH 10 Apagar la unidad de alimentacion Esperar 3 min hasta que la punta de soldadura se haya enfriado 4 Sostener el lapiz de soldadura con la punta ligeramente hacia abajo Sujetar firmemente el lapiz por la zona de la empunadura trasera 4 y desenroscar el portapuntas 3 girandolo hacia la izquierda Extraer el portapuntas 3 hacia delante La punta de soldadura 2 se encuentra ahora suelta en el portapuntas 3 e La 1 A y Y d D bn e ot e S N Za 9 ADA E LAS e LJ e o NO b d y WA ai E No colocar ni dejar enfriar la punta de soldar o medir sobre la esponja de limpieza o superficies de pl stico Si se trabaja con distintos tipos de puntas de soldadura se recomienda utilizar la punta de soldadura 2 y el portapuntas 3 juntos para que los cambios resulten m s r pidos ver 3 figuras superiores Mantener siempre limpias las superficies de transmisi n t rmica de las puntas de soldadura y el cuerpo calefactor El elemento calefactor no debe entrar en contacto con el esta o para soldar ES 8 8 WXP 120 Instalaci n de una punta de soldadura nueva 5 Introducir la punta de soldadura en el portapuntas con la punta hacia delante Colocar el portapunt
10. e proporciona un comportamiento din mico excelente Su reducido dise o y la corta distancia entre el mango y la punta permiten utilizar este l piz de soldar de forma universal desde los trabajos m s precisos hasta aquellos que requieran mayor temperatura El WXP 120 est equipado con un sistema de detecci n de uso que desconecta autom ticamente el aparato o lo pone en modo de inactividad cuando no se est utilizando El LED de estado se ala el estado de funcionamiento del aparato La informaci n relativa al ajuste de temperatura para el modo de inactividad as como de los tiempos de desconexi n aparece recogida en el manual de uso de la unidad de alimentaci n WX Nota El l piz de soldadura WXP 120 de Weller debe utilizarse nicamente con las unidades de alimentaci n Weller WX ES 6 8 jADVERTENCIA WXP 120 4 2 Datos t cnicos Rango de temperatura 100 C 450 C 212 F 850 F Cable de la herramienta Elemento calefactor Sensor de temperatura Potencia de calentamiento Tension de calentamiento Tiempo de calentamiento Conector Peso de la herramienta Tipo de punta Unidad de alimentacion Caucho de silicona resistente al fuego Alambre de calefaccion integrado Sensor de platino 120 W 24V aprox 14 s 50 C a 380 C 120 F a 660 F Conector de 6 polos con proteccion contra polaridad inversa y mecanismo de bloqueo 42 g incluida punta sin cable Seri
11. econocidas No obstante existe riesgo de da os personales y da os a la propiedad si se hace caso omiso a la informaci n de seguridad establecida en el folleto adjunto que acompa a a este manual de instrucciones y a las advertencias mencionadas al respecto ES 4 8 Indicaciones generales Manejo de las puntas de soldadura desoldadura WXP 120 Entregue siempre el lapiz de soldadura WXP 120 a terceros junto con este manual de uso El fabricante no asumir ning n da o resultante del uso indebido de la herramienta ni de modificaciones no autorizadas 2 1 Tener en cuenta lo siguiente Colocar siempre el l piz de soldadura WXP 120 en el soporte de seguridad previsto a tal efecto Retirar todos los objetos inflamables de las proximidades de la herramienta de soldadura Llevar siempre una indumentaria protectora adecuada al utilizar el WXP 120 Mantener siempre vigilado el WXP 120 caliente No trabajar en piezas sometidas a tensi n Los materiales pl sticos antiest ticos contienen sustancias de relleno conductoras para impedir que se puedan producir cargas est ticas De esta forma tambi n quedan mermadas las propiedades aislantes del material pl stico No trabajar en piezas sometidas a tensi n Llevar siempre protecci n ocular al trabajar con aplicaciones de soldadura y desoldadura Leer y respetar las indicaciones recogidas en el manual de uso de la unidad de alimentaci n Weller WX No c
12. ekt auf die Lotstelle nicht auf die Lot Entl tspitzen Wenden Sie auf die L t Entl tspitzen keine berm ige Kraft an Immer darauf achten dass der L tkolben ordnungsgem in der Sicherheitsablage liegt WXP 120 5 8 2 2 Bestimmungsgemafer Gebrauch Verwenden Sie den WXP 120 L tkolben ausschlie lich fur den in der Betriebsanleitung bez glich L sen Verstauung und Ablage von elektronischen Bauteilen angegebenen Zweck unter den hier beschriebenen Bedingungen Der bestimmungsgem e Gebrauch des L tkolbens WXP 120 beinhaltet auch dass Sie diese Anleitung beachten Sie alle weiteren Begleitunterlagen beachten Sie die nationalen Unfallverh tungsvorschriften am Einsatzort beachten Der Hersteller bernimmt keine Haftung f r Sch den die aus unsachgem em nicht dem in der Betriebsanleitung beschriebenen Gebrauch oder unerlaubten Anderungen am Ger t resultieren 3 Lieferumfang WXP 120 verpackt T0052920199 WXP 120 L tkolben T0052920199 XT B Mei elspitze 2 4 X 0 8 mm T0054470400 Betriebsanleitung WXP 120 Zus tzlich beim WXP 120 L tset 10052920299 WDH 10 Sicherheitsablage T0051512199 Steckverbinder f r Fu platte T0058703153 Betriebsanleitung WDC 2 4 Geratebeschreibung 4 1 L tkolben WXP 120 Der WXP 120 Lotkolben zeichnet sich durch ein schnelles und prazises Erreichen der Lotspitzentemperatur aus Aufgrund seines besonders leistungsfahigen 120 W Heize
13. en Sie nicht die hei en L tspitzen und halten Sie entz ndbare Objekte fern 1 Den Lotkolben WXP 120 vorsichtig auspacken 2 Den L tkolben in der Sicherheitsablage WDH 10 ablegen 3 Den Anschlussstecker 6 an der Versorgungseinheit anschlie en und durch Drehen im Uhrzeigersinn verriegeln 4 berpr fen Sie ob die Netzspannung mit der Spannungsangabe auf dem Typenschild der WX Versorgungseinheit bereinstimmt 5 Die Versorgungseinheit einschalten und die gew nschte Temperatur einstellen 6 Hat das Werkzeug die gew nschte Temperatur erreicht leuchtet die LED Status Anzeige 4 dauernd Die L tspitze mit Lot benetzen 6 Wechsel der WXP 120 L tspitzen Verbrennungsgefahr Die L tspitze wird bei L t und Entl tvorg ngen sehr hei Bei Ber hrung der L tspitze besteht Verbrennungsgefahr gt Das L twerkzeug muss in ausgeschaltetem Zustand mindestens 3 Minuten in der Sicherheitsablage WDH 10 verbleiben bis die L tspitze abgek hlt ist LED Status Anzeige 4 muss Aus sein L tspitzen d rfen nur gewechselt werden wenn sie kalt sind WXP 120 7 8 Auswechseln einer verbrauchten Spitze 1 Lotwerkzeug in die Sicherheitsablage WDH 10 legen 2 Netzschalter der Versorgungseinheit ausschalten 3 Drei Minuten warten bis die L tspitze abgek hlt ist 4 L tkolben mit der Spitze leicht nach unten halten L tkolben am hinteren Griffteil 4 fest halten und Spitzenhalter 3 mit Linksdrehung abschrauben S
14. er This does not apply to claims by the buyer for indemnification in accordance with 478 479 BGB German Federal Law Gazette We shall only be liable for claims arising from a warranty furnished by us if the quality or durability warranty has been furnished by use in writing and using the term Warranty In addition for the USA and Canada Cooper Tools warrants to the original purchaser and any subsequent owner Buyer that Weller soldering and desoldering products will be free from defects in material and workmanship for a period of one year from date of purchase provided that no warranty is made with respect to products which have been altered subjected to abuse or improperly used installed or repaired Use of non Cooper Tools components will void this warranty if a non Cooper Tools component is defective or is the source of the defect Cooper Tools will repair or replace products found to be defective not caused by a part component or accessory manufactured by another company during the warranty period Contact Cooper Tools with dated proof of purchase and return to Apex Tool Group LLC 14600 York Rd Suit A Sparks MD 21152 All costs of transportation and reinstallation shall be borne by the Buyer IN NO EVENT SHALL COOPER TOOLS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES COOPER TOOLS LIABILITY FOR ANY CLAIMS ARISING OUT OF THIS WARRANTY SHALL NOT EXCEED THE PURCHASE PRICE OF THE PRODUCT THE PERIOD OF
15. ering point not on the soldering desoldering tips Do not apply excessive force to the soldering desoldering tips Always make sure that the soldering iron is placed properly in the safety rest WXP 120 5 8 2 2 Intended use Use the WXP 120 soldering iron exclusively for the purpose indicated in the operating instructions of releasing accommodating and depositing electronic components under the conditions specified herein Intended use of the WXP 120 soldering iron also includes the requirement that you adhere to these instructions observe all other accompanying documents comply with national accident prevention guidelines applicable at the place of use The manufacturer accepts no liability for any damage resulting from failure to use the device in compliance with these operating instructions or unauthorised modifications to the device 3 Included in delivery WXP 120 packed T0052920199 Soldering iron WXP 120 T0052920199 XT B chisel tip 2 4 X 0 8 mm T0054470400 Operating instructions of WXP 120 Also included in WXP 120 soldering set T0052920299 WDH 10 safety rest T0051512199 Sole plate connector T0058703153 Operating instructions of WDC 2 4 Device description 4 1 Soldering iron WXP 120 The WXP 120 soldering iron is characterised by fast and precise achievement of the soldering tip temperature A highly powerful 120 W heater element provides excellent dynamic performan
16. fully unpack the WXP 120 soldering iron 2 Place the soldering iron into safety rest WDH 10 3 Insert the connecting plug 6 into the power supply socket and lock it by turning it clockwise 4 Check to make sure that the mains voltage matches the voltage specified on the rating plate of the WX supply unit 5 Switch on the supply unit and set the required temperature 6 If the tool has not reached the required temperature the status indicator LED 4 will be lit continuously Wet the soldering tip with solder 6 Replacing the WXP 120 soldering tips Risk of burns The soldering tip becomes hot during soldering and desoldering Processes There is a risk of burns from touching the soldering tip gt The soldering tool must be switched off and stand at least 3 min in the safety rest WDH 10 until the soldering tip has cooled off The status indicator LED 4 must be OFF Only replace the soldering tips when they are cold WXP 120 7 8 Replacing a used soldering tip 1 Place the soldering tool in the WDH 10 safety rest 2 Switch off the supply unit 3 Wait three minutes until the soldering tip has cooled off 4 Hold the soldering iron with the tip pointing downward Hold the soldering iron by the rear handle 4 and unscrew the tip receptacle 3 by twisting it anticlockwise Pull off the receptacle 3 forwards The soldering tip 2 is now loose in the receptacle 3 Note Te CCE pe OK I Mr S
17. lementes wird ein ausgezeichnetes dynamisches Verhalten erreicht Zusammen mit der schlanken Bauform und der kurzen Distanz vom Griff Zur L tspitze findet dieser L tkolben universellen Einsatz von extrem feinen L tarbeiten bis hin zu solchen mit erh htem Warmebedarf Der WXP 120 ist mit einer Nutzungserkennung ausgestattet und kann bei Nichtgebrauch automatisch in Standbybetrieb bzw Aus geschaltet werden Durch die LED Statusanzeige wird der jeweilige Betriebszustand angezeigt Das Einstellen der Standbytemperatur sowie die Schaltzeiten entnehmen Sie bitte der Betriebsanleitung der jeweils verwendeten WX Versorgungseinheit Hinweis Der L tkolben WXP 120 von Weller darf nur mit den Weller WX Versorgungseinheiten betrieben werden DE 6 8 WARNUNG WARNUNG AN WXP 120 4 2 Technische Daten Temperaturbereich 100 C 450 C 212 F 850 F Werkzeugkabel Silikonkautschuk hitzebestandig Heizelement Integriertes Heizdrahtelement Temperatursensor Platinsensor Heizleistung 120 W Spannung Heizung 24V Aufheizzeit ca 14s 50 C auf 380 C 120 F auf 660 F Anschluss 6 poliger St verpolungssicher mit Verriegelung Gewicht 42 g incl Spitze ohne Kabel Spitzentyp XT Baureihe Versorgungseinheit Weller WX Stationen 5 Inbetriebnahme des Ger tes Verbrennungsgefahr Die L tspitzen vom L tkolben werden beim L t Entl tvorgang sehr hei Bei Ber hrung der Spitzen besteht Verbrennungsgefahr gt Ber hr
18. lt nicht fur R ckgriffsanspr che des Kaufers nach 88 478 479 BGB Aus einer von uns abgegebenen Garantie haften wir nur bei Anspruchen wenn die Beschaffenheits oder Haltbarkeitsgarantie von uns schriftlich und unter Verwendung des Begriffs Garantie abgegeben worden ist Technische nderungen vorbehalten Die aktualisierten Betriebsanleitungen finden Sie unter www weller eu WXP 120 Operating Instructions EN WXP 120 WXP 120 Hardware Overview WDH 10 1 Cleaning element 4 LED status indicator 2 Soldering tip 5 Heat resistant antistatic silicon cable 3 Tip handle 6 Lockable connector plug WXP 120 3 8 Table of Contents 1 About these d ee CR 3 SEENEN egene 3 3 Included in delivery ANEREN 5 4 Device descriptlion zes 5 5 Commissioning the device eee nn 6 6 Replacing the WXP 120 soldering ups 6 7 ACCOSSOMOS sehen is 9 DISHO nat 7 GW e En EE 8 1 About these instructions Thank you for the confidence you have shown in buying the Weller WXP 120 soldering iron The device has been manufactured in accordance with the most rigorous quality standards which ensure that it operates perfectly These instructions contain important information which will help you to start up operate and service the WXP 120 soldering iron safely and correctly as well as to eliminate simple faults or malfunctions yourselves gt Read these instructions and the accompanying safety information carefully bef
19. n i Sg SS LA Fab ZP a S wv i ki CN A 9 ANS LA i E vw m mi zu am Do not place or leave the hot soldering tip or probe tip on the cleaning sponge or on plastic surfaces When using multiple types of soldering tip it is recommended that the soldering tip 2 and tip receptacle 3 be used together in the changing system see figure above Keep the heat transfer surfaces of the soldering tip and heating element clean The heating element must not come into contact with soldering tin Inserting a new soldering tip 5 Place the soldering tip into the tip receptacle with the tip pointing forwards Push the tip receptacle together with the soldering tip over the heating element and rotate clockwise to tighten 6 Switch on the supply unit and set the required temperature 7 Accessories 7 1 XT soldering tips for the WXP 120 soldering iron See the table XT soldering tips for WXP 120 soldering iron in the section in the back and at www weller eu 7 2 Replacement parts and accessories for WXP 120 Order no Description T0052920199 WXP 120 soldering iron T0051512199 WDH 10 safety rest T0051384199 Metal wool for cleaning element for WDC 2 8 Disposal Dispose of replaced equipment parts filters or old devices in accordance with the rules and regulations applicable in your country EN WXP 120 9 Warranty Claims by the buyer for physical defects are time barred after a period of one year from delivery to the buy
20. ni oa cari oa O inu n iri na fo ont anti 8 8 Eliminaci n de residuosS occcccoononcccccnonnonoconononcnoncnnnnconcnonnnos 8 A ee res 8 1 Acerca de estas instrucciones Le agradecemos la confianza depositada en nosotros al comprar el l piz de soldadura WXP 120 de Weller La fabricaci n de este aparato est sometida a los m s rigurosos controles de calidad para garantizar un perfecto funcionamiento del mismo Este manual de uso contiene informaci n importante para poder poner en marcha y manejar de forma segura y adecuada el l piz de soldadura WXP 120 as como para realizar tareas de mantenimiento e incluso reparar peque as aver as gt Lea atentamente estas instrucciones de uso y las indicaciones de seguridad adjuntas antes de poner en funcionamiento el l piz de soldadura WXP 120 gt Mantenga este manual de uso en un lugar al que puedan acceder todos los usuarios del aparato 1 1 Directivas que tener en cuenta El l piz de soldadura WXP 120 de Weller dispone de la Declaraci n de Conformidad CE que certifica el cumplimiento de los requisitos b sicos de seguridad contemplados en las Directivas 2004 108 CE y 2006 95 CE 1 2 Documentos aplicables Manual de instrucciones para la unidad de alimentaci n Manual de uso para el WXP 120 2 Acerca de la seguridad El l piz de soldadura WXP 120 ha sido fabricado conforme a los ltimos avances tecnol gicos y las normativas y disposiciones de seguridad r
21. not work on electrically live parts Antistatic plastics are provided with conductive fillers to prevent the build up of static charge This also reduces the insulating properties of the plastic Do not work on electrically live parts Always wear eye protection when working with soldering and desoldering applications Read and follow the operating instructions for the Weller WX supply unit Do not place or leave hot soldering desoldering tips on the worktop or on plastic surfaces Wet the tinned soldering desoldering tips with solder once they have heated up in order to remove oxide layers that form during storage or contamination from the soldering desoldering tips Ensure the soldering desoldering tips are well wetted during intervals between soldering and desoldering and prior to storage of the device Do not use aggressive fluxing agents Always make sure that the soldering desoldering tips are properly seated Select the lowest possible working temperature Select the largest possible soldering desoldering tip shape for the application roughly as large as the soldering pad Wet the soldering desoldering tips well to ensure efficient heat transfer between the soldering desoldering tips and the soldering spot Switch off the system if you do not intend to use the soldering desoldering tool for prolonged periods Wet the tips before placing the soldering desoldering tool in the safety rest Apply the solder directly at the sold
22. olocar ni dejar las puntas de soldadura desoldadura calientes sobre la esponja limpiadora ni sobre superficies de pl stico Recubrir las puntas de soldadura desoldadura esta adas al calentar el soldador por primera vez as se eliminar n todas las pel culas de xido o impurezas de las puntas de soldadura desoldadura que se hayan acumulado durante el almacenamiento Durante las interrupciones de la soldadura desoldadura y antes de almacenar la herramienta asegurarse de que las puntas de soldadura desoldadura est n bien recubiertas No utilizar fundentes agresivos Asegurarse siempre de que las puntas de soldadura desoldadura est n colocadas correctamente Seleccionar una temperatura de trabajo lo m s baja posible Seleccionar unas puntas de soldadura desoldadura lo m s largas posibles para la aplicaci n aprox de la longitud de la placa de soldar Recubrir bien las puntas de soldadura desoldadura para asegurarse una transferencia de calor eficiente entre las puntas de soldadura desoldadura y el punto de soldadura Desconectar el sistema si no est previsto utilizar la herramienta de soldadura desoldadura durante largos periodos de tiempo Recubrir las puntas antes de colocar la herramienta de soldadura desoldadura en el soporte de seguridad Soldar directamente en el punto de soldadura no en las puntas de soldadura desoldadura No someter las puntas de soldadura desoldadura a fuerzas f sicas WXP 120 5 8 Asegurar
23. ore starting up the device and starting work with the WXP 120 soldering iron gt Keep these instructions in a safe place and so that they are easily accessible to all users 1 1 Directives taken into consideration The Weller WXP 120 soldering iron conforms to the specifications of the EC Declaration of Conformity as defined by Directives 2004 108 EC and 2006 95 EC 1 2 Applicable documents Operating instructions for your supply unit Operating instructions for WXP 120 2 For your safety The WXP 120 soldering iron has been manufactured in accordance with the current state of the art and recognised safety rules and regulations There is nevertheless the risk of personal injury and damage to property if you fail to observe the safety information set out in the accompanying booklet and the warnings given in these instructions EN 4 8 General information Handling soldering de soldering tips WXP 120 Always pass on the WXP 120 soldering iron to third parties together with these operating instructions The manufacturer accepts no liability for improper use of the tool or for unauthorised modifications 2 1 Please observe the following guidelines Always place the WXP 120 soldering iron in the intended safety rest Remove all inflammable articles from around the hot soldering iron Always wear suitable protective clothing when using the WXP 120 Never leave a hot WXP 120 unattended Do
24. pitzenhalter 3 nach vorne abziehen L tspitze 2 befindet sich nun lose im Spitzenhalter 3 Hinweis Die L tspitze Messspitze nicht auf dem Reinigungsschwamm oder Kunststoffoberfl chen ablegen bzw abk hlen Bei der Verwendung von mehreren L tspitzentypen wird empfohlen die L tspitze 2 und den Spitzenhalter 3 zusammen in dem Wechselsystem zu verwenden siehe 3 Bild oben Die W rme bertragungsfl chen von L tspitze und Heizk rper sauber halten Das Heizelement darf nicht mit L tzinn in Ber hrung kommen Einsetzen einer neuen L tspitze 5 L tspitze mit der Spitze nach vorne in Spitzenhalter einlegen Spitzenhalter zusammen mit der L tspitze ber das Heizelement schieben und mit Rechtsdrehung festdrehen 6 Netzschalter der Versorgungseinheit einschalten und die gew nschte Temperatur einstellen 7 Zubeh r 7 1 XT Lotspitzen f r den L tkolben WXP 120 Siehe Tabelle XT L tspitzen f r L tkolben WXP 120 am Ende dieser Anleitung und auf www weller eu 7 2 Ersatzteile und Zubeh r f r WXP 120 Bestell Nr Beschreibung T0052920199 WXP 120 L tkolben T0051512199 Sicherheitsablage WDH 10 T0051384199 Spiralwolle fur Reinigungseinsatz fur WDC 2 8 Entsorgung Entsorgen Sie ausgetauschte Gerateteile Filter oder alte Gerate gem den Vorschriften Ihres Landes DE 8 8 WXP 120 9 Garantie Die Mangelanspruche des Kaufers verjahren nach einem Jahr ab Ablieferung an ihn Dies gi
25. se siempre de que el lapiz de soldadura esta colocado correctamente en el soporte de seguridad 2 2 Uso reglamentario Emplear el lapiz de soldadura WXP 120 exclusivamente para el proposito indicado en el manual de uso en lo referente a la liberacion alojamiento y fijacion de componentes electronicos bajo las condiciones especificadas aqui Dentro del uso previsto para el l piz de soldadura WXP 120 tambi n se incluye lo siguiente Seguir las instrucciones de este manual Seguir las instrucciones de todos los documentos que acompa an al aparato Cumplir las normas de prevenci n de accidentes laborales vigentes en el pa s de uso El fabricante no asumir ning n da o resultante del uso incorrecto de este aparato en cumplimiento con el presente manual de instrucciones o de las modificaciones no autorizadas en el aparato 3 Piezas suministradas WXP 120 embalado 10052920199 L piz de soldadura WXP 120 10052920199 Punta de cincel XT B de 24X08mm T0054470400 Manual de uso para WXP 120 Elementos adicionales para el juego de soldadura WXP 120 10052920299 Soporte de seguridad WDH 10 10051512199 Acoplamiento para la base 10058703153 Manual de uso para WDC 2 4 Descripci n del aparato 4 1 Lapiz de soldadura WXP 120 El l piz de soldadura WXP 120 se distingue por su rapidez y precisi n para alcanzar la temperatura deseada La extraordinaria potencia 120 W de su elemento calefactor l
26. uhaltende Richtlinien Der Weller L tkolben WXP 120 entspricht der EG Konformit tserkl rung gem den grundlegenden Sicherheitsanforderungen der Richtlinien 2004 108 EG und 2006 95 EG 1 2 Geltende Unterlagen Betriebsanleitung fur Ihre Versorgungseinheit Betriebsanleitungen fur WXP 120 2 Zu lhrer Sicherheit Der Lotkolben WXP 120 wurde nach dem neuesten Stand der Technik und anerkannten Sicherheitsregeln und bestimmungen entsprechend hergestellt Bei Nichtbeachtung der beiliegenden Sicherheitsinformationen und aufgefuhrten Warnhinweise besteht jedoch die Gefahr von Personen und Sachschaden Geben Sie den WXP 120 Lotkolben nur zusammen mit dieser Betriebsanleitung weiter DE 4 8 Allgemeine Hinweise Umgang mit Lot Entlot spitzen WXP 120 Der Hersteller ist nicht haftbar f r Sch den die aus einer unsachgemafien Verwendung des Werkzeugs oder unerlaubten Veranderungen am Gerat entstehen 2 1 Beachten Sie bitte Folgendes Legen Sie den L tkolben WXP 120 immer in die vorgesehene Sicherheitsablage Entfernen Sie alle entz ndbaren Objekte aus der N he des hei en L twerkzeugs Tragen Sie bei der Arbeit mit WXP 120 entsprechende Schutzkleidung Lassen Sie den hei en WXP 120 nie unbeaufsichtigt F hren Sie keine Arbeiten an unter Spannung stehenden Teilen aus Antistatische Kunststoffe sind zur Verhinderung von statischen Ladungen mit leitenden F llstoffen versehen

Download Pdf Manuals

image

Related Search

Related Contents

Operator Workstation User`s Manual: Defining Access Cards (11/01  Procedura installazione e manutenzione per filtri  User Manual - Skiva Technologies Inc.  Cornelius 620718955 User's Manual      Fisher-Price N1128N1128 User's Manual    Secvest 2WAY    

Copyright © All rights reserved.
Failed to retrieve file