Home
Cornelius 620718955 User's Manual
Contents
1. CC OF vekis D Water Flow Device Test Kit Installation Instructions INSTALLATION INSTRUCTIONS WATER FLow DEVICE TEST KIT The water flow device is used to determine if adequate water supply is available to support the machines that are connected to them The device is equipped with a quarter turn ball shut off valve and a blank flare cap that permits the determination of Static Water Pressure not flowing In addition there are three orifice flare caps used to determine the Water Flow Rate and Pressure 7 i l j j i i i i bi WATER FLOW DEVICE PIN 629088461 BLANK NO 1 MO 2 NO 3 pur VS ORIFICE 3 16 ORIFICE 13 64 ORIFICE 10 GPH 200 GPH y0 GPH FIGURE 1 FIGURE 2 Connection Shut off water coming from the back room Connect the water supply line using the applicable adapter fitting not supplied to the 1 2 ID pigtail on the water flow device Turn off 14 turn valve before turning on the back room water supply After connected proceed with the following Static Pressure Check Place the flare gasket and blank flare cap on the device Open turn valve and read pressure gauge If pressure reads below 25 PSIG there is no need to go any further Correct the supply problem before proceeding If the pressure exceeds 60 PSIG we recommend a water pressure regulator be installed Flowing Pressure Check Estimate the water usage of all equipment connected to the water delivery system e g IntelliCarb 125 GP
2. H a two flavor Pinnacle 100 GPH Total 225 GPH Select the Number 3 13 64 orifice to insure that it can supply more than the 225 GPH required to operate both units Close the turn valve and remove the blank flare cap Install the flare cap with the proper size orifice to match the flow rate desired and open the turn valve Direct the water flow in to a large container sink or floor drain for at least 20 seconds Read the pressure gauge while the water is flowing If the gauge maintains 25 PSIG or higher the water supply is sufficient for the flow rate that was selected Part Number Stamp Number Orifice Diameter 620718956 13 64 Release Date August 23 2004 www cornelius com Revision A 2004 IMI Cornelius Inc 1 Publication Number 629088461INS
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 ~"`~-) Baixar Manual EU Style Energy Meter - Eco DEH-P9800BT - Pioneer Europe - Service and Parts Supply website Akva Lux II TDP-F - Danfoss Chauffage si le repreneur est un professionnel Katalogtitel Copyright © All rights reserved.
Failed to retrieve file