1. 1 Main switch 2 Remote lock connect emergency switch 3 Dip switch mode DMX address selection see below 4 DMX 512 in out 5 Microphone sensitivity 6 Mains connection 7 ILDA in out Operating modes The following operating modes can be selected from the DIP switch on the back side of the device Dip switch Mode 1 0 0 0 0 0 0 0 0 1 Automatic 0 0 0 0 0 0 0 0 0 1 Music active XXX XXX XXX 1 DMX Music active patterns are changed animated to the beat of the music Sensitivity can be adjusted at the back panel Automatic mode patterns are changed automatically DMX DMX512 Mode Use the first 9 switches to select the address D D D x x D D D x 1 2 4 8 16 32 64 128 256 e g 1000 0000 01 DMX mode address 1 1 0 0 0 0 0 0 0 0 0 0010 0100 01 DMX mode address 36 0 0 4 0 0 32 0 0 0 Manual Bedienungsanleitung CS 600 RGBV 4 10 DMX control channel Function 1 Mode 0 69 laser off 70 139 sound mode 140 209 animated sound mode see above 210 255 DMX mode 2 Pattern 3 Effect channel Strobe 4 Horizontal movement 0 no effect 1 167 fixed movement 168 188 animated movement left to right with increasing speed 189 209 dto Right to left 210 255 dto left to right and back 5 Vertical movement analogous to hor movem 6 Zoom 0 10 no effect 11 104 increasing size 105 154 growing with increasing speed 155 204 dt
2. 0 0 0 0 0 0 0 0 0 1 Musiksteuerung X X X X X X X X X 1 Automatisch Grafik Musiksteuerung Muster werde im Rhythmus ge dert animiert Empfindlichkeit kann an der Geh user ckseite eingestellt werden Automatisch Muster werden automatisch durchgewechselt DMX DMX512 Modus Adresseinstellung ber die ersten 9 Schalter x D D D D D D D x 1 2 4 8 16 32 64 128 256 Z B 1000 0000 01 DMX Modus Adresse 1 1 0 0 0 0 0 0 0 0 0 0010 0100 01 DMX Modus Adresse 36 0 0 4 0 0 32 0 0 0 DMX Steuerung Kanal Belegung 1 Betriebsmodi 0 69 Laser aus 70 139 Soundmodus 140 209 animierter Soundmodus 210 255 DMX Modus 2 Muster Animation 3 Effektkanal Strobe Blinken mit zunehmender Geschwindigkeit Manual Bedienungsanleitung CS 600 RGBV 8 10 4 Horizontale Bewegung 0 kein Effekt 1 167 feste Auslenkung 168 188 Bewegung von links nach rechts mit zunehmender Geschwindigkeit 189 209 dto Rechts nach links 210 255 dto Hin und her 5 Vertikale Bewegung analog Kanal 4 6 Zoom Gr e 0 10 kein Effekt 11 104 zunehmende Gr e 105 154 automatisch gr er werdend mit zunehmender Geschwindigkeit 155 204 dto Kleiner 205 255 dto gr er kleiner 7 Breite Rotation um Y 0 150 feste Rotation 151 255 automatisch mit zunehmender Geschwindigkeit 8 H he Rotation um X analog Kanal 7 9 Drehung 0 180 feste Drehung 181 217 automatisch mit zunehmender Geschwind
3. CS 600 RGBV Read carefully before using this device Bedienungsanleitung Bitte lesen Sie diese Bedienungsanleitung bevor Sie das Ger t in Betrieb nehmen ebe 2 INS TALLATION OPERA TION sis 2 USING the laSr anna 3 Control panel EE 3 Operating EEN 3 DMX ll EE 4 DEE eege 4 Maintenance cleaning E 4 Troubleshooting E 4 IUDA SIGN Gl WE 5 Technical SPECITIESTIORS aaa 5 Please MONG EE 5 Hinweise zur Inbetriebnahme 000er 6 WamMNWEISE seudair a AA a EESERLHEUENENEHENENERHEUENEREREUEHERFERENENENENE 6 Inbetriebnahme 7 Bedienelemente ai nenne 7 Betriebs MOi sariem ae 7 DMX STEUERUNG sssusa a visas aa 7 ILDA Steuerung reed 8 PRG NMG WE 8 ME Tt Le E 8 ILDA Ansteuerung dereen 9 Technische Daten ass 9 E En E ue EE 9 Checking parts Please check if all listed parts are included and are not damaged Included 1 x Laser projector 1 x Power cable 1 x 9 pin plug 2 x key 1 x manual Safety instructions If the device has been exposed to great temperature changes do not switch it on immediately Condensation water may damage your device Leave the device switched off until it has reached room temperature The laser must only be used for shows Any operation has to be attended and supervised by a skilled and welltrained operator Never leave this device running unattended and keep it away from children and unauthorized persons Keep away from heaters and other heat sources In order to safeguard sufficient ventilation lea
4. dass kein Nebelfluid im Inneren kondensiert Nebel sollte vor dem Ger t sein nicht darin e Einige Tage nach jeder Neuinstallation Geh use ffnen und nachpr fen ob sich Kondensat bildet Gegebenenfalls Position von Laser Nebelmaschine ndern Ger t ausschalten wenn es nicht benutzt wird Auch wenn die Diode nicht leuchtet sie ist an solange das Ger t an ist Warnhinweise am Ger t Laser Strahlung Vor Benutzung Anleitung durchlesen Nicht dem Strahl aussetzen Betrieb nur durch qualifiziertes Personal Laserstrahl nie auf Menschen richten Laserklasse 4 Nie in den Laserstrahl schauen Laserstrahlung bei ge ffnetem Geh use Nur in geschlossenen R umen betreiben Am Strahlaustritt Bestrahlung vermeiden Austritt von Laserstrahlung Inbetriebnahme Verbinden Sie das Ger t mit dem Stromnetz schliessen Sie einen Notaus Schalter mit dem remote lock Anschluss an ffnen Sie den Shutter und drehen Sie den Schl ssel auf on Der Laserstrahl tritt nun aus der vorderen ffnung Vorsicht Bedienelemente 1 Ein Ausschalter 2 Remote lock Anschluss f r Notaus Schalter 3 Dip switch Modus DMX Adresseinstellung 4 DMX 512 in out 5 Mikrofon Empfindlichkeit 6 Netzanschluss 7 ILDA in out Betriebsmodi Am dip switch an der Geh user ckseite k nnen Sie folgende Betriebsmodi eistellen Dip switch Modus 1 0 0 0 0 0 0 0 0 1 Automatisch
5. do not use in the rain or damp and dusty environment don t put liquid filled containers on the device Projector should be put in a water proof housing when operated outside Regularly open the device see cleaning further down to check for dust inside or if fog fluid condenses in the housing if so rearrange hazer and or laser position Operating temperature is 10 35C In a new installation check after some 15 30 minutes whether the outlet air gets too warm Regularly check the inside for dust deposits especially around the fans Let laser cool off 10 minutes after 2 hours of operation to ensure maximum lifetime for the diode Distance between laser aperture and projection screen should be not less than 1 meter Do not turn device on and immediately off again frequently Do not look into the laser beam directly especially not with optical instruments Do not touch the device with wet hands When the laser diode becomes dim or broken please contact your dealer When returning laser to dealer manufacturer always use original packaging Maintenance should be performed every 15 day period See cleaning further down To ensure maximum lifetime of the laser Don t overheat the laser e Always ensure good ventilation e Don t have stage lights especially moving heads directed towards the laser e Regularly clean the fans and the interior from dust e In a new installation check the temperature after 30 minutes of operatio
6. hrleistung bernommen Sollten nderungen an dieser Bedienungsanleitung vorgenommen werden k nnen wir Sie dar ber nicht in Kenntnis setzen Bitte kontaktieren Sie f r Fragen Ihren H ndler F r Service wenden Sie sich bitte an Ihren H ndler oder an Laserworld Verwenden Sie bitte nur Laserworld Ersatzteile nderungen vorbehalten Aufgrund der Datenmenge kann keine Gew hr f r die Richtigkeit der Angaben bernommen werden Manual Bedienungsanleitung CS 600 RGBV 10 10 Laserworld Switzerland AG Kreuzlingerstrasse 5 8574 Lengwil Oberhofen SWITZERLAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil Oberhofen SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau www laserworld com info laserworld com representative according to EMVG Cleantech Europe GmbH Managing Director Thomas Schulze F rkhofstr 5 81927 M nchen DE
7. music mode ILDA Lasersources aircooled DPSS laser green diode laser red blue violet Optical power at the laser CS 600 RGBV max 600mW gt 60mW 532nm green gt 250mW 655nm red gt 140mW 405nm violet blue e Beam ca 3mm imrad Laser class 4 Scanning system Galvo system 25 000 PPS at 4 Scanangle max 40 Weight 7 kg Dimensions 33 x 31 x 17 cm W x Dx Hi Loudness lt 70db Please note This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a Safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Laserworld cannot be made liable for damages caused by incorrect installations and unskilled operation This manual is subject to changes without notification errors and omissions expected Contact your local dealer for an update or check our website www laserworld com For service contact your dealer or Laserworld Only use Laserworld spare parts Manual Bedienungsanleitung CS 600 RGBV 6 10 Lieferumfang Bitte pr fen Sie ob Sie wirklich alle Teile erhalten haben und ob diese von der Lieferung unbesch digt sind Zum Lieferumfang geh ren 1 x Laser Projektor 1 x Kaltger tekabel zur Stromversorgung 1 x 9 poliger Blindstecker 2 x Schl ssel 1 x Bedienungsanleitung Hinweise zur Inbetriebnahme Bitte stellen Sie sicher dass die auf dem Ger t angegebene Spannung d
8. Sie den Laser nicht zusammen mit anderen grossen elektrischen Verbraucher insbesondere Nebelmaschinen zusammen auf derselben Leitung Sorgen Sie immer f r eine ausreichende Bel ftung Insbesondere d rfen die Bel ftungs ffnungen nicht verdeckt sein Netzstecker Kaltger tebuchse zug nglich halten Stellen Sie sicher dass das Ger t nicht zu heiss wird berpr fen Sie nach einer Installation an einem neuen Platz nach ca 15 30 Minuten ob die Abluft sehr warm wird Stellen Sie sicher dass das Ger t nicht dem Strahl von Scheinwerfern ausgesetzt werden insbesondere bei beweglichen Scheinwerfern diese k nnen in kurzer Zeit zur berhitzung f hren Stellen Sie sicher dass der Netzstecker gezogen ist wenn Sie am Ger t hantieren bzw es installieren oder es zum Reinigen ffnen Das Ger t nicht schnell hintereinander Ein und Ausstecken da dies die Lebensdauer der Laserdiode erheblich verk rzen kann Das Ger t sollte sich nach einer Stunde Dauerbetrieb f r ca 15 Minuten abk hlen Stellen Sie sicher dass das Ger t fest montiert wird um Vibrationen zu vermeiden Warnhinweise Beim Entfernen des Garantielabels erlischt sofort jeder Anspruch auf Gew hrleistung Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung Benutzen Sie das Ger t nicht wenn sichtbare Besch digungen am Geh use den Anschlussfeldern und vor allem an den Stromversorgungsbuchsen oder kabel vorliegen Niemals direkt in den Strahl des austr
9. Sie einen Adapter der die Pins 4 und 17 verbindet ILDA Ansteuerung Belegung des Standard ILDA Signals 1 Scanner X 5V 5V 14 X 5V 5V 2 Scanner Y 5V 5V 15 Y 5V 5V 3 Intensity Blanking OV 2 5V 16 Intensity Blanking 0 2 5V 4 Interlock A 17 Interlock B 5 Red 0 2 5V 18 Red 0 2 5V 6 Green 0 2 5V 19 Green 0 2 5V 7 Blue 0 2 5V 20 Blue 0 2 5V 8 12 Not used 23 24 Not used 13 Shutter 5V max 20 mA 25 GND Signal ground Masse Technische Daten e Laserquellen luftgek hlter DPSS Laser gr n Diodenlaser rot blau violett Laserleistung am Laser min 450mW max 600mW gt 60mW 532nm gr n gt 250mW 655nm rot gt 140mW 405nm blau violett e Laserklasse 4 Betriebsmodi DMX 512 Automatik Modus Musik Modus ILDA Scannnersystem Galvos 25000pps bei 4 Scanwinkel max 40 DMX 512 12 Kan le Strahldaten ca 3mm imrad Stromversorgung 85 250V AC Stromaufnahme 50W Abmessungen 330 x 310 x 170 mm BxTxH Gewicht 7 kg Betriebstemperatur 10 35 C Lautst rke lt 70db Technische nderungen vorbehalten Abschliessende Erkl rung Sowohl Produkt als auch Verpackung sind beim Verlassen der Fabrik einwandfrei Der Benutzer des Ger ts muss die lokalen Sicherheitsbestimmungen und die Warnhinweise in der Betriebsanleitung beachten Sch den die durch unsachgem sse Handhabung entstehen unterliegen nicht dem Einflussbereich der Herstellers und H ndlers Somit wird keine Haftung bzw Gew
10. e the device Clean the mirrors with window cleaner and a paper towel Never look directly into the light source Always disconnect from the mains when the device is not in use or before cleaning it Troubleshooting Problem Possible cause No function fan not working Check mains connection Effects don t change to the beat of the music Adjust sensitivity with the dial on the back Check if device isn t in DMX or autom mode Problems with DMX control Check DMX address selection Device not working but fan working Turn device off for ca 1 minute Laser does not switch to ILDA mode e The interface does not connect pins 4 and 17 Interlock of the IDLA signal See interface manual e The cable does not connect pins 4 and 17 Use a cable that connects pins 4 and 17 e Use an adapter that connects pins 4 and 17 Manual Bedienungsanleitung CS 600 RGBV 5 10 ILDA signal Pin out of the standard ILDA signal 1 Scanner X 5V 5V 14 X 5V 5V 2 Scanner Y 5V 5V 15 Y 5V 5V 3 Intensity Blanking OV 2 5V 16 Intensity Blanking 0 2 5V 4 Interlock A 17 Interlock B 5 Red 0 2 5V 18 Red 0 2 5V 6 Green 0 2 5V 19 Green 0 2 5V 7 Blue 0 2 5V 20 Blue 0 2 5V 8 12 Not used 23 24 Not used 13 Shutter 5V max 20 mA 25 GND Signal ground Technical specifications Power supply AC 85V 250V Ambient temperature 10 C 35 C Power consumption 50 W Operation modes DMX 512 automatic
11. er entspricht mit der Sie es betreiben wollen bevor Sie den Laser in Betrieb nehmen Der Laser darf nur von technisch versiertem Fachpersonal gem ss den im jeweiligen Land geltenden Sicherheitsbestimmungen installiert werden Insbesondere die darin geforderten Sicherheitsabst nde zwischen Ger t und Publikum bzw maximal zul ssige Bestrahlungswerte m ssen immer eingehalten werden In bestimmten L ndern kann zus tzlich eine Abnahme durch ein technisches berwachungsinstitut erforderlich sein Wenn ein Remote Anschluss am Ger t vorhanden ist verbinden Sie einen Not Ausschalter mit dem Remote Lock Anschlusses auf der Geh user ckseite Falls Sie keinen Not Ausschalter benutzen stecken Sie den beigef gten 9 poligen Blindstecker in die Remote Buchse Falls kein Remote Anschluss vorhanden ist benutzen Sie einen Notaus Schalter in der Stromzuf hrung Halten Sie bei der Installation einen Mindestabstand von 15 cm zur Wand und 1 m zu feuergef hrlichen Materialien Dekoration oder sonstigen Installationen ein Bringen Sie zur sicheren Installation ein Sicherheitsfangseil an Das Fangseil sollte mindestens dem 10 fachen Gewicht des Ger ts standhalten k nnen Wenn das Ger t grossen Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer eine Steckdose mit Schutz Erdleiter Benutzen Sie niemals Dimmer Funk oder andere elektronisch gesteuerten Steckdosen Falls m glich benutzen
12. etenden Lasers blicken Erblindungsgefahr Ger t nicht bei hoher Luftfeuchtigkeit Regen oder in staubiger Umgebung betreiben Vor Tropf Spritzwasser sch tzen keine mit Fl ssigkeit gef llten Gef sse auf dem Ger t abstellen ffnen Sie das Ger t in regelm ssigen Abst nden insbesondere nach Installation an einem neuen Platz und berpr fen Sie ob sich Nebelfluid im Inneren absetzt Falls ja reinigen Sie das Ger t und ndern Sie die Position von Ger t und oder Nebelmaschine berpr fen Sie ebenfalls ob sich Staub insbesondere im Bereich der Laser und L fter ansammelt Falls ja Ger t reinigen sonst droht Gefahr des berhitzens Feuchtigkeit und Hitze k nnen die Lebensdauer stark verk rzen und f hren zum Erl schen der Garantie Das Ger t bzw das Stromkabel nie mit nassen H nden anfassen Sollten St rungen am Ger t oder der Diode auftreten setzen Sie sich bitte mit Ihrem H ndler in Verbindung Manual Bedienungsanleitung CS 600 RGBV 7 10 Um die Lebensdauer Ihres Lasers zu erh hen Sch tzen Sie das Ger t vor berhitzung e Immer f r ausreichende Ventilation sorgen e Keine Scheinwerfer insbesondere kopfbewegte auf das Ger t richten e Regelm ssig das Innere und besonders die L fter von Staub reinigen e Nach jeder Neuinstallation nach ca 30 Minuten die Temperatur pr fen und gegebenenfalls das Ger t an einen k hleren besser bel fteten Standort bringen Ger t trocken halten e Stellen Sie sicher
13. igkeit im Uhrzeigersinn 218 255 dto gegen den Uhrzeigersinn 10 Blanking 0 70 kein Effekt 71 139 Punkte werden betont 140 209 Linienst cke werden gestrichelt gezeichnet 210 255 nur Punkte werden gezeichnet 11 Welle 12 nur RGY RGBV Farbe 0 19 weiss etc 6 Farben 139 188 Regenbogen statisch 189 248 Regenbogen dynamisch 249 255 Farbwechsel Bitte beachten Sie dass nicht jeder Effektkanal bei allen Mustern aktiv ist Z B kann bei dynamischen Mustern die Gr e nicht ge ndert werden etc Kanal 3 Strobe ist auch im Soundmodus Kanal 1 70 209 verf gbar ILDA Steuerung Wenn ein ILDA kompatibles Interface angeschlossen wird schaltet das Ger t in den ILDA Modus Die Steuerung erfolgt ber geeignete PC Software Die Scanner sind f r ca 10000 PPS bei 20 25 optisch eingestellt Wenn Sie die Scanner schneller betreiben verkleinern Sie bitte die Auslenkung Reinigung Reinigen Sie das Ger t regelm ssig um seine lange Lebensdauer zu erhalten Trennen Sie dazu das Ger t unbedingt zuvor vom Netz Schauen Sie niemals direkt in den Laserstrahl Zum ffnen entfernen Sie 8 Schrauben des Deckels und nehmen den Deckel ab Entfernen Sie eventuelle Staubansammlungen insbesondere im Bereich der L fter und Laser Sollten sich Spuren von Nebelfluid absetzen Ger t reinigen und Position von Ger t und oder Nebelmaschine ndern Verwenden Sie zur Reinigung klares Leitungswasser oder Alkohol und ein weiches Tuch F
14. n Keep the laser dry e Make sure fog hazer fluid doesn t condensate inside the laser fog has to be in front of the laser not inside e A few days after each new installation open the cover to check if fluids condensate inside e If fluids condensate inside reposition the laser or fogger hazer Turn the device off when not used The diode is on when the device is on Even if it is not lit If the laser is equipped with a remote connector connect an emergency switch to the Remote lock connector on the backside the switch has to interrupt the connection between pins 1 and 2 to turn off the laser If no emergency switch is used insert the 9 pin dongle instead If the laser has no remote lock or the 9 pin dongle is used use an emergency switch in the mains connection Using the laser Caution use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Rigidly mount projector Projector can be mounted in any position Make sure the correct voltage is used Connect mains Connect an emergency switch to the 9 pin connector Interlock connector on the backside pins 1 and 2 If you do not wish to connect an emergency switch connect the 9 pin plug instead and use an emergency switch in the mains connection Open shutter and turn key to on position the laser beam will now exit through the front opening be careful Control panel
15. o shrinking 205 255 dto growing shrinking 7 Width rotation about y 0 150 fixed rotation 151 255 automatic rotation with incr speed 8 Height rot About X analogous to width 9 Rotation 0 180 fixed rotation 181 217 automatic with incr speed clockwise 218 255 do counter clockwise 10 Blanking 0 70 no effect 71 139 points are brighter 140 209 dashed lines 210 255 points only 11 Wave 12 Colour 0 19 white etc 6 colours 139 188 rainbow static 189 248 rainbow moving 249 255 colour change Please note that not all effect channels are available for all patterns E g you can t zoom dynamic patterns etc Channel 3 strobe is also available when in soundmode channel 1 70 209 ILDA mode When an ILDA compatible interface is connected to the laser the laser is automatically switched to ILDA mode Output is then controlled by a PC running laser control software The scanners are set for ca 10000 PPS at 20 25 optical When running faster reduce image size scan angle Maintenance cleaning Always disconnect from the mains when the device is not in use or before cleaning it Open the device by removing top cover remove 8 screws Remove any deposits of dust especially at the fan Check for condensed fog fluid inside If so clean and rearrange the position of laser and or hazer Mirrors need cleaning when a halo is noticeable around the beam or an unusual high amount of diffuse light can be seen insid
16. oved Indoor use only At front opening Avoid exposure laser radiation is emitted INSTALLATION OPERATION Don t remove the warranty serial number label removal voids warranty The operator has to make sure that laser radiation for laser class 4 also reflected laser radiation higher than the maximum permissible level is avoided by technical or organisational measures Especially with respect to the MPE see above Make sure to use the correct voltage Use a power socket with earth ground Don t use dimmer RC or other electronically switched sockets Whenever possible don t use the laser together with large appliances especially fog machines on the same mains If the device is used in a flying installation the mounting brackets and an appropriate safety rope must be used In some countries the operator must notify the accidence insurance and the authority for industrial safety before operating a laser For more information contact the relevant authorities Please consider that unauthorized modifications on the device are strictly forbidden due to safety reasons If this device will be operated in any way differently than described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like shortcircuit burns electric shock etc Manual Bedienungsanleitung CS 600 RGBV 3 10 Keep surrounding dry and clean This unit should be keep dry
17. r eine optimale Lichtausbeute sollten die Spiegel sauber und ohne Kratzer sein Bereits kleinste Kratzer k nnen die Ger teleistung erheblich beeintr chtigen Sie sollten die Spiegel reinigen wenn ein deutlicher Halo um den Laserstrahl zu erkennen oder ungew hnlich viel Streulicht im Ger t zu sehen ist Spiegel idealerweise mit Aceton und Linsenpapier alternativ mit Fensterreiniger und Papierwischtuch reinigen Immer in eine Richtung wischen um die Auswirkung m glicher Kratzer zu minimieren Fehlerbehebung Fehlfunktion Behebung Ursache Keine Funktion kein L fterger usch Stromversorgung berpr fen Die Lasereffekte wechseln nicht in Abh ngigkeit Erh hen Sie die Lautst rke der Musik oder erh hen Sie die von der Musik Empfindlichkeit mithilfe des Reglers an der R ckseite des Lasers berpr fen Sie dass sich das Ger t nicht im DMX oder Automatikmodus befindet Es treten Probleme bei der DMX Steuerung auf berpr fen Sie die korrekte Einstellung der Adressen Keine Funktion aber L fterger usch vorhanden Ger t ausschalten und nach ca 1 Minute wieder einschalten Manual Bedienungsanleitung CS 600 RGBV 9 10 Ger t l sst sich nicht ber ILDA ansteuern e Die Interfacekarte hat die Pins 4 und 17 nicht verbunden vergewissern Sie sich im Manual der Interfacekarte e Das verwendete Anschlusskabel verbindet diese Pins nicht Verwenden Sie ein Kabel das diese Pins verbindet e Benutzen
18. ve 50 cm of free space around the device Never direct the laser beam to people or animals CAUTION LASER DIODE If you open the device for cleaning always disconnect from mains HEALTH HAZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL cause eye damage So these laser series models supplied with a key switch to prevent unauthorized use warning labels and aperture labels affixed to the laser Installation safety Prior to installation and operation of the laser the paths of the beams and effects should be considered particularly with respect to how they will reach the audience If direct audience scanning is desired then the laser energy in the effects needs to be considered to decide if the effects are safe for direct viewing Always ensure that the maximum permissible exposure MPE is not exceeded in the area accesible to the public So install the laser in such a way that minimum distances and heights ensure the MPE is never exceeded in the public area When setting up the laser make sure the laser is affixed firmly to avoid vibrations Warning labels on the device Laser radiation Read manual before use Operation by qualified personal only Never direct laser Beam at people Never look directly into beam Avoid exposure To the beam Laser class 4 Caution of radiation If cover is rem