INSTALLATION MANUAL CONVENI-PACK

image

Contents

1. 7 1 Example of Wiring Entire System Note 1 For Remote switch use non voltage contact for microcurrent not more than 1mA 12VDC Note 2 Total capacity for warning alarm 0 5A or less at AC 220 to 240V Capacity for operation output 0 5A or less at AC 220 to 240V TI Timer for refrigeration EtH Electromagnetic contactor SIT Thermostat for inner temperature adjustment T2 Timer for freezer Defrost heater 52T Defrost completion thermostat Ry0 Ry3 Relay HIP Defrost lamp Y15 Solenoid valve Earth leakage circuit breaker Integrated heat control board Field suppl Freezer showcase For earth fault overload and 9 Upp Y Os sl short circuit protection KI M n En oO EEE Note 1 so am 3 phase 380 415V Remote switch Earth leakage circuit breaker B o High frequency type La For earth fault overload and l Short circuit protection Outdoor ES P unit RY3 SIT zem e 6 L1L2L3 N A1A2 Alarm panel X o RR Caution ro YI Caution
2. Schaltkastendeckel Heben Sie diese Klappe o an und LED ffnen Sie die Abdeckung H1 8P Y BEBE Ji 3 Sicht ffnungsabdeckung Sicht ffnung Sicht ffnung linke Seite 7 rechte Seite us Betriebsschalter RUN amp chaltkiaston p Bee OFF un Go cal al Sicht ffnung linke Seite obere linke Seite des Schaltkastens N WARNUNG Verwenden Sie Schutzausr stung z B Schutzhandschuhe und Schutzbrille beim Nachf llen von K ltemittel Achten Sie auf den rotierenden L fter wenn die Frontplatte w hrend der Arbeit ge ffnet wird Der L fter kann noch eine Weile nachlaufen nachdem das AuBenger t abgeschaltet worden ist K ltemittel Nachf llung ACHTUNG Siehe Funktionsweise des Absperrventils f r die Steuer methode der Absperrventile Fl ssiges K ltemittel darf auf keinen Fall direkt ber eine Gasleitung nachgef llt werden Fl ssigkeitskompression kann zu einem Ausfall des Kompressors f hren Schlagen Sie im Wartungshandbuch die Anweisungen in Bezug auf die zus tzliche K ltemittelbef llung nach wenn Innenger te nur an die Klimaanlagenseite bzw nur an die Gefrierseite ange schlossen werden Ist das einzige angeschlossene Innenger t eine Klimaanlage wenn die Vitrine nicht an die Klimaanlagen Seite angesc
3. X4M Kabelspezifikationen N ACHTUNG Verwenden Sie einen spannungslosen Kontakt f r Mikrostrom f r den Fernsteuerschalter nicht mehr als 1 mA 12 V DC Soll der Fernbetriebsschalter zum Starten und Stoppen des Ger ts verwendet werden stellen Sie den Betriebsschalter auf REMOTE lt Vorsichtsma nahmen f r Klemmenanschl sse gt Verwenden Sie unbedingt die mit den Isolierh llen gelieferten ringf rmigen Crimpklemmen Verwenden Sie die vorgeschriebenen Stromkabel f r die Verka belung und sichern Sie die Kabel so dass keine externen Kr fte auf den Klemmenblock einwirken Crimpklemmen Stromkabel Md Ne Isolierh lle Verwenden Sie zum Anziehen der Schrauben der Anschlussklemmen einen passenden Schraubendreher Ein zu kleiner Schraubendreher besch digt die Schraubenk pfe und kann die Schrauben nicht richtig festziehen Ziehen Sie die Klemmschrauben nicht berm ig fest weil sonst die Schrauben besch digt werden k nnen Die Anzugsmomentwerte der Klemmschrauben sind aus der nachstehenden Tabelle ersichtlich Nehmen Sie den Erdleiter aus der Kerbe der Tellerscheibe her aus und verlegen Sie das Kabel sorgf ltig damit andere Kabel nicht an der Scheibe h ngen bleiben Anderenfalls hat der Erdle iter eventuell keinen ausreichenden Kontakt und der Erdungsef fekt des Kabels kann verloren gehen L
4. Ry0 Ry3 Relais HIP Abtaulampe Y15 Magnetventil Erdschlussschalter Integrierte Warmekontrolltafel vor Ort zu beschaffen Gefriervitrine zum Schutz vor Erdschluss NGC RES ND Ej berlastung und Kurzschluss KI Mo n EIH Ei E Anmerkung 1 x 9 mu 3 Phasen Strom 380 415 V Fernsteuerschalt Erdschlussschalter L4 NES Hochfrequenztyp T PEA zum Schutz vor Erdschluss l berlastung und Kurzschluss Au eng ES P er t AY SIT 6 Alarmtafel a a Ee m x 3 er RI3 pn TITS Wamungsausgabe AC 220 240 V Ho mung oW 1 Achtung Ausgang Anmerkung 2 4 Timer f r Gefriermaschine Gefrierger tek hler No geingang Gefrierungsbetriebsausgang Anmerkung 2 x IP on AC220 2401 XICA pe oW m e X2M Innen Au en Au en Au en noc i rd Be e Ee Timer f r Gefrierung piam ME AC220 240V No hlvitrine ica F r die Gefriermaschine Ern Verzweigungsschalter 1P N groom i F r das K hlger t SIT chutzschalter FEN T f Fern m FI Innen F2 steuerung L___ _ ger t K hlvitrine _ 1P AC 220 240 l Zusatzger t AY RYZ Ry2 io sr Erdschlussschalter 86 XIM metano oll J LE Hochfrequenztyp EM E J um Schulz or Gefrierbetriebausgang AC220 240V berlastung und XM o oo ool Kurzschluss 2 A 14 ZST Controller 11 Wamungs Sensor 1 l 1 eingang Eingang re Fernsteuerschalter H ane Vitrinensch
5. H1 H3 Difference in height Max permissible a b c d 130m d1 is d or e whichever is longer one way piping length equivalent length i i In case of no connection a2 b2 el lt 130m e1 is d2 or e2 whichever is longer with booster uni Outdoor unit Max branch piping length actual length b c d1 lt 30m d1 is d or e whichever is longer 2 a CT D2 b2 e1 lt 30m e1 is d2 or e2 whichever is longer i L ad Y 8 imn eu er Max difference in unit below outdoor unit H1 H2 lt 35m Note en c2 IS ho Unit height between indoor i Lor 1 and outdoor units unit above outdoor unit H1 H2 lt 10m 2 LLL cL Note Difference in height between unit cooler and showcase H3 x 5m When connecting the booster unit refer to the installation manual i A a z rovided for the booster unit Difference in height between air conditioner indoor units H4 lt 0 5m E Note A trap is required at 5 m intervals from outdoor unit Refrigerant piping size Refrigeration Piping size mm Liquid pipe Gas pipe Piping between outdoor unit and first 50m or less 50 130m 50m or less 50 130m branch A a Outdoor unit side 9 5 x 0 8 O type 912 7 x 0 8 O type 25 4 x 1 0 1 2H type 28 6 x 1 2 1 2H type Piping between branching areas Select the piping from the following table in accordance with the total capac
6. Eur we we cog rit A ie o N sg gl e e S 3 2 iE e D Y Y Service space gt Service space z h1 A Actual height h2 B Actual height 500 X 500 h1 2 or over Y 300 h2 2 or over Y 100 h2 2 or over Values in parentheses are for pattern 2 AN CAUTION Branch switch overcurrent breaker Earth leakage breaker Control panel Warning panel eer Branch switch overcurrent breaker Earth leakage breaker E 21500 Showcase mm 1 An inverter CONVENI PACK may cause electronic noise gener ated from AM broadcasting Examine where to install the main CONVENI PACK and electric wires keeping proper distances away from stereo equipment personal computers etc Particularly for locations with weak reception ensure there is a distance of at least 3 meters for indoor remote controllers place power wiring and transmission wiring in conduits and ground the conduits 2 When installing in a locations where there is heavy snowfall implement the following snow measures Ensure the base is high enough that intakes are not clogged by snow Mount a snow protection hood optional accessory Remove the rear intake grille to prevent snow from accumulat ing on the fins 3 If con
7. 8 3 Checking of Device and Installation Conditions ig 9 CHECKS AFTER WORK COMPLETION enn 10 REFRIGERANT REPLENISHMENT eneee 11 TEST RUN 1 FIRST OF ALL This document is an installation manual for the Daikin CONVENI PACK Before installing the unit read this manual thoroughly and following the instructions contained in it After installation do a test run to make sure the unit runs properly and then explain how to operate and take care of the unit to the customer using the operation manual Lastly make sure the customer keeps this manual along with the operation manual in a safe place This manual does not describe how to install the indoor unit Refer to the installation manual included with the indoor unit for that 1 1 Safety Precautions Please read these Safety precautions carefully before installing the CONVENI PACK and be sure to install it correctly After completing installation conduct a trial operation to check for faults and explain to the customer how to operate the CONVENI PACK and take care of it with the aid of the operation manual Ask the customer to store the installation manual along with the operation manual for future reference Meaning of WARNING and CAUTION notices result in personal injury or loss of life IN CAUTION Failure to observe these instructions properly may result in property damage or personal injury which may be serious depending on
8. Installieren Sie ein mechanisches thermostatisches R410A Expansionsventil an jedem Innenger t Isolieren Sie den F hlerblock des mechanischen thermostatis chen Expansionsventils Installieren Sie ein R410A Magnetventil max Betriebsdifferenz druck von 3 5 MPa 35 bar oder mehr auf der Prim rseite des oben beschriebenen mechanischen thermostatischen Expan sionsventils f r jedes Innenger t Installieren Sie einen Filter auf der Prim rseite des oben bes chriebenen Magnetventils f r jedes Innenger t Ermitteln Sie den Filterfeinheitswert anhand der vom verwendeten Magnetventil und mechanischen thermostatischen Expansionsventil vorge schriebenen Gr e Verlegen Sie die Leitung zum Innenger t W rmetauscher so dass das K ltemittel von oben nach unten flie t Wenn mehrere Innenger te installiert werden m ssen sie auf gleicher H he installiert werden Verwenden Sie entweder Aus Zyklus Entfrostung oder Elektro heizungs Entfrostung als Entfrostungstyp Modelle mit Hei gas Entfrostung k nnen nicht verwendet werden 3 AUSWAHL DES STANDORTS W hlen Sie einen Installationsort der die folgenden Bedingungen erf llt Holen Sie sich die Erlaubnis des Kunden 1 Es besteht keine Brandgefahr aufgrund von austretendem Gas 2 W hlen Sie den Standort f r die Einheit so aus da weder die ausgeblasene Luft noch das Betriebsger usch der Einheit zu Bel stigungen f hrt Deutsch Das Fundament ist stark gen
9. Wenn Stromkabel und bertragungskabel angeschlossen wer den auf keinen Fall einen Thermistor Sensor usw ausbauen Bei Betrieb ohne Thermistor Sensor usw kann der Kompressor besch digt werden Dieses Produkt besitzt einen Phasenumkehrschutzdetektor der nur funktioniert wenn die Stromversorgung eingeschaltet wird Falls die Gefahr besteht dass w hrend des Betriebs des Produkts ein Stromausfall auftritt oder die Stromversorgung aus und wieder eingeschaltet wird ist eine Phasenumkehrs chutzschaltung einzubauen Der Betrieb des Produkts mit umgekehrter Phase kann zu einer Besch digung des Kompres sors und anderer Teile f hren Das Stromkabel sicher anbringen Die Stromzufuhr mit fehlender N Phase oder falscher N Phase f hrt zu einer Besch digung des Ger tes Die Stromversorgung auf keinen Fall mit umgekehrter Phase anschlie en Das Ger t kann mit umgekehrter Phase nicht normal funktion ieren Falls der Anschluss mit umgekehrter Phase vorgenommen wird sind zwei der drei Phasen zu vertauschen Darauf achten dass der elektrische Unsymmetriegrad nicht gr er als 2 ist Wird dieser Wert berschritten verringert sich die Lebensdauer des Ger tes Wird der Wert von 4 berschritten schaltet sich das Ger t aus und ein St rungscode wird auf der Fernbedienung des Innenger tes angezeigt Das vorgeschriebene Kabel sicher anschlie en und mit der ange brachten Klemme sichern ohne u eren Druck auf die Klem
10. 7 19 Warning output AC220 240V i i Tp OC 1 Caution output Note 2 LA EIE 7 Warning eH How p Timer for freezer Refrigeration unit cooler I PAE M pe pu Refrigeration operating output Note 2 B IP l T AC220 240V XIN AIP mo UM m XM In Out Out Out n t Be loto o Timer for refrigeration pa mi z AC220 240V No efrigeration showcase AC220 240V E ELS Branch switch 1 For freezer 1P Overcurrent For refrigerator SIT circuit breaker ADO A Remote OAE FiF2 Indoor F2 controller Ld unit Refrigeration showcase IP SIT AC 220 240V Booster unit fe A WE Lo oma Earth leakage circuit 53 XIM ote oll J LE breaker ES E d High frequency type Fe SR FERE For earth fault igi con a overload and short Du lol o o bi circuit protection 2 A 14 ZST controller LLo Warning Sensor Pal n 1 input imu re Remote switch 62 anne Showcase interface zi Note 1 ca n A Q AC220 240V RA IA Note 7 2 Procedure for Incoming Wiring Use conduit for power supply wiring Make sure the weak electric wiring i e for the remote controller between units etc and the power wiring do not pass near each other keeping them at least 50 mm apart Proximity may cause electrical interference malfunctions and breakage Be sure to connect the power wiring to the power wiring terminal block and secure it as described in 7 2 Procedure for Incoming Wiring Do not connect the power supply to the termina
11. Schneiden Sie die Quetschleitung klein mit einem geeigneten Werkzeug wie z B einem Rohrschneider ab und ffnen Sie den Querschnitt um zu pr fen dass dort kein Rest l ist Anmerkung L uft Ol aus dem Querschnitt Schneiden Sie die Quetschleitung gro mit einem Rohrschneider ab und entfernen Sie die Quetschleitung N WARNUNG Trennen Sie die Quetschleitung ab nachdem Sie das K ltemit telgas in den Rohrleitungen eingesammelt haben Die Rohrleitungen k nnen explodieren und Verletzungen k nnen durch Schmelzen der Hartlotlegierung verursacht werden wenn das Gas in den Rohrleitungen nicht vollst ndig abgelassen wird Funktionsweise des Absperrventils Befolgen Sie die nachstehenden Anweisungen zur Bet tigung des jeweiligen Absperrventils ACHTUNG ffnen das Absperrventil nicht bevor die in 8 3 berpr fen des Ger ts und der Installationsbedingun gen beschriebenen Schritte abgeschlossen sind Lassen Sie das Absperrventil nicht ge ffnet ohne die Stromver sorgung einzuschalten weil sonst K ltemittel im Kompressor kondensieren und die Isolierung des Hauptstromversorgungskre ises sich verschlechtern kann Verwenden Sie unbedingt ein Spezialwerkzeug f r die Handhabung des Absperrventils Das Absperrventil ist keine R ckblattausf hrung Bei Aus bung einer berm igen Kraft kann das Ventil besch digt werden Verwenden Sie einen F llschlauch f r den Wartungsansch
12. 27 0 33 0 exagon 05 075 wrench 8mm Opening method 1 Remove the valve cover and turn the shaft anticlockwise with a hexagon wrench 2 Turn the shaft until the shaft stops 3 Tighten the valve cover securely Refer to the above table for the tightening torque according to the size Closing method 1 Remove the valve cover and turn the shaft clockwise with a hexa gon wrench 2 Tighten the shaft until the shaft comes in contact with the sealing part of the valve 3 Tighten the valve cover securely Refer to the above table for the tightening torque according to the size Handling Precautions for Valve Cover Be careful not to damage the sealing part Atthe time of mounting the valve cover apply a screw lock agent to the screw thread Do not apply a screw lock agent for flare nut use to the sealing part Be sure to tighten the valve cover securely after operating the valve Refer to Operation Method of Shutoff Valves for the tightening torque of the valve Screw thread Apply a screw lock agent Valve cover B jV Shutoff valve Part of mounting the Sealing part valve cover Not apply a screw lock agent English Handling Precautions for Service Port e Work on the service port with a charge hose provided with a push ing rod Atthe time of mounting the cap apply a screw lock agent to the screw thread Do not apply a screw lock agent for flare nut
13. Is the power turned on Is the wire broken or incorrectly wired between the power the indoor unit and the remote controller Has the fuse on PCB melted Take the following action if you find a malfunction code on the remote controller during the test run pe Va Defect at installation Action to be taken Fully open the shutoff E3 E4 Shutoff valves closed values L4 The air passage is blocked ici obstacles Blocking the air passage Ut Reverse phase of the power Exchange two wires out of supply three power supply wires U2 Voltage drop Check the voltage drop Check the connection of U4 UF Wrong wiring of transmis transmission lines between sion lines between units the outdoor unit and the air conditioner Check if the air conditioner is UA uisi of system dis connected as should be y assembled E2 Electric leak See 1 1 Set the operating switch to the OFF position to reset the power sup p If ly and then return the switch to the ON position to restart the unit the problem persists refer to the Service Manual f you have changed the power wire and the transmission line keep the power of the indoor unit air conditioner refrigeration showcase refrigeration unit cooler and the integrated heat con trol board turned on turn off the operation switch of the outdoor units and never fail to press the push button switch BS5 on PCB A1P in the electric accessor
14. Leitungsgr e mm Leitung zwischen Au enger t und erster Verzweigung A2 a2 Fl ssigkeitsrohr Gasrohre 50 m oder weniger 50 130m 50 m oder weniger 50 130mm 09 5 x 0 8 O typ 012 7 x 0 8 O typ 625 4 x 1 0 1 2H typ 628 6 x 1 2 1 2H typ Leitung zwischen Verzweigungsbereichen B2 b2 W hlen Sie aus nachstehender Tabelle die Leitungen entsprechend der Gesamtkapazit t der nachgeschalteten Innenger te Gesamtkapazit t der Innenger te nach der Verzweigung Gr e der Gasleitung Gr e Fl ssigkeitsrohr Weniger als 16 0 kW 15 9 x 1 0 1 2H typ 16 0 kW oder mehr und weniger als 22 4 kW 919 1 x 1 0 1 2H typ 22 4 kW oder mehr und weniger als 28 0 kW 22 2 x 1 0 1 2H typ 9 5 x 0 8 O typ Keine Gr e nach der Verzweigung darf die Gr e vorgelagerter Leitungen bersteigen Leitung zwischen Verzweigungsbereichen und jedem Ger t bersteigt die Gr e des Anschlussrohrs des Innenger ts die des in voranstehender Tabelle dargstellten Zweigrohrs vergr ern Sie die Gr e des Anschlussrohrs in der N he des Innenger ts bevor Sie es anschlie en Deutsch 6 2 Schutz gegen Verunreinigung bei der Installa tion der Rohre Sch tzen Sie die Rohrleitungen vor dem Eindringen von Feuchtigkeit Schmutz Staub usw Ort Installationszeitraum Schutzmethode L nger als ein Monat Quetschen des Rohrs Au enger at
15. Usecharge hoses provided with a pushing rod each when using the service ports In case of possible water intrusion into piping Perform the above mentioned vacuum drying for 2 hours first in the following cases The product is installed in the rainy season there is a fear of dew condensation resulting in the piping because the installation work period is long or there is a fear of rainwater intrusion into the piping for other reasons Then impose a pressure of up to 0 05 MPa with nitrogen gas for vacuum destruction and vacuum the unit down to 100 7 kPa or below for 1 hour with a vacuum pump for vacuum drying Repeat vacuum destruction and vacuum drying if the pressure does not reach 100 7 kPa or below after a minimum of 2 hours vacuum ing Leave the vacuum state for 1 hour then and check that the vac uum gauge reading will not rise 8 2 Thermal Insulation Work Be sure to perform thermal insulation of the piping after the air tight test and vacuum drying Besureto perform the thermal insulation of the liquid and gas pipes in the connecting piping Otherwise water leakage may result Be sure to insulate liquid and gas connection piping Failure to do so may result in water leakage Consult the following chart as a general guide when selecting the insulation thickness Liquid pipe arrival minimum temperature 20 C Air conditioning side 5 C Refrigeration side Gas pipe arrival minimum temperature
16. f UL igers ayse uno efe gy lt gt NENAS efjgy lt A gt Ae esjeuunpeq Q uawjoepeps 8 Atusod uouue Bo lt y gt awwoywe y Jap WOS ZL kumzod lt y gt bloejuetunyop 2 elupobz L uuezs Augaysnue 2 2 e sapjejba e eyozebi g z e ueldeye v z e gy lt O gt Veo 6que lt g gt ABSIUENPOB yoo v Bua LL wneyeeduou Wwaog 09 gibredW 60 we og3ejele eulojuoo SEAIS BO sglnououtod AnoX3 SMUO AMIAUQO 20 eoy pow ep 9uoo eAnjeg 90 opepueuua o unbos seajoaiig 50 plaepuaweab sjeoz uauliquoy po Sagiipoui anb saya seaqoauig E0 Gunsepuy geueb uemjer 20 papuauie se seupoeli LO 03 80 1 7003 Au gnedwoy ogeuBeuiog2e 3 93 18 86 Maeg Arau yoeyy 93 96 9003 ebeyoA MOT zewejndn wigeu s npes n ejsuoy iuo as ep efan zn eui uiojueuunyop wuagewsou wBnIp y ewui wopiepuejs wigepal s es npepis n gL umueuinyop uuluNjeuuou oqeu WeULOU ujoifnpejseu Ifep nodpo AuAyod wigeu s npejnos A Auea zn n nos ez npepjodpajd ez p nisesieynui ueipsepuejs ueinee nas JEBEISEA EL JBSYNUJSUI 31A n pjouuet seynuq ass p je ne Bulujass nioy Japun 1e uewnyop epueGuuou espue Jaye e piepuejs epuebjgj pew 3sjgwwejssueueno 18 J ISIM eAnyedsel ZL JOLOWANASUI BARA paw eseuiuugjssueJeAo Jays Bulupugaue pe BuluNESINIO Jepun uetunyop epuenjbuou ejpue Jaja 19 prepuejs epuefioj 1940 uoo paw asjewurjssuelono poyn Je Buruisnan eumedsoi LL YaSynusul 2104
17. gef llt worden ist e Achtung ffnen Sie sofort die Absperrventile auf der Gas und Fl s sigkeitsseite vollst ndig Anderenfalls kann es zu einer Explo sion der Rohrleitungen durch Fl ssigkeitsabdichtung kommen Schaltkasten Anweisungsaufkleber auf K ltemittel Nachf llung oo oo QQ OOQ UL jJ Anbringungsposition des Aufklebers 1 Der Innendruck der Flasche f llt ab wenn nur noch wenig K lte mittel in der Flasche brig ist so dass eine F llung des Ger ts unm glich ist selbst wenn die ffnung des Fl ssigkeitsabsper rventils eingestellt wird Ersetzen Sie in dieser Situation die Flasche durch eine die noch mehr K ltemittel enth lt Falls au erdem die Rohrleitungsl nge lang ist kann die Nachf l lung bei vollst ndig geschlossenem Fl ssigkeitsabsperrventil zur Aktivierung des Schutzsystems f hren so dass der Betrieb des Ger ts angehalten wird Tragen Sie nach dem Abschluss der Arbeit Gewindebindemittel f r B rdelmuttern auf die Gewinde der Absperrventile und der Wartungsanschl sse auf Siehe Handhabungsvorkehrungen f r Ventildeckel und Handhabungsvorkehrungen f r den Wartungsanschluss unter Deutsch 17 6 5 Anschluss der K ltemittelleitungen f r die Handhabung der Ventildeckel und Wartungsanschl sse 2 Nachdem die K ltemittel Nachf
18. llung abgeschlossen ist tragen Sie die tats chliche Menge der K ltemittel Nachf llung in das Feld Gesamtmenge der K ltemittel Nachf llung auf dem Anweisungsaufkleber f r K ltemittel Nachf llung am Au enger t ein Die Anbringungsposition des Anweisungsaufklebers f r K ltemit tel Nachf llung ist aus der Abbildung ersichtlich siehe die obige Abbildung Vorsichtsma nahmen f r K ltemittelflaschen Pr fen Sie zum Zeitpunkt der K ltemittel Nachf llung ob das Saugheberrohr vorhanden ist Ordnen Sie dann die Flasche so an dass das K ltemittel im fl ssigen Zustand eingef llt wird siehe nach stehende Tabelle R410A ist ein gemischtes K ltemittel dessen Zusammensetzung sich ndern kann und der normale Betrieb des Systems kann unm glich sein falls das K ltemittel im gasf rmigen Zustand eingef llt wird 3 Schalten Sie den Betriebsschalter der Inspektionst r des Au enger ts ein Der Au enl fter dreht in circa 10 Minuten nachdem der Betriebsschalter eingeschaltet wurde und der Ver dichter startet 4 Dr cken Sie die Taste EIN AUS auf der Fernbedienung des Au enger ts Klimaanlage um das Ger t zu betreiben 5 berpr fen Sie den Dichtungszustand durch das Schauglas des Au enger ts Pr fen Sie bei einem Mangel an K ltemittel ob das K ltemittel bis zur angegebenen F llh he bef llt wurde 6 Pr fen Sie Folgendes an jeder Einheit Flasche mit Saugheberrohr C Ste
19. see diagram below Do not operate the maintenance shutoff valve The factory setting for the maintenance shutoff valve is open During operation always leave this valve in the open position Operating the unit with the valve in the closed position may cause the compressor to fail Maintenance shutoff valve Maintenance shutoff valve Liquid side shutoff valve provided with service port ui gt BE Ir 5 Gas side shutoff valve provided with service port 1 Directions to bring out the pipes The local interunit piping can be connected either forward or to the sides taken out through the bottom as shown in the following figure When passing out through the bottom use the knock hole in the bottom frame Ig g gg Y Ya JUUL Left side connection Precautions when knocking out knock holes Open knock hole in the base frame by drilling the 4 concave around it with a 6mm bit Knock hole Drill Concave section 4 places Be sure to avoid damaging the casing After knocking out the holes we recommend you remove any burrs and paint them using the repair paint to prevent rusting When passing electrical wiring through the knock holes protect the wiring with a conduit or bushings making sure not to d
20. 0 C Air conditioning side 20 C Refrigeration side Reinforce the insulation material for the refrigerant piping accord ing to the environment of thermal installation Otherwise the sur face of the insulation material may result in dew condensation 14 English fthe dew condensation water on the shutoff valves is likely to flow to the indoor unit side through the clearance between the insula tion material and piping because the outdoor unit is installed above the indoor unit or for some other reasons perform appro priate treatment such as the caulking of the joints see the illus trations below Attach the cover of the piping outlet with a knock hole opened If there is a feature of small animals intruding through the piping outlet cover the piping outlet with a blocking material field sup ply on completion of the steps of 10 REFRIGERANT REPLEN ISHMENT see the illustrations below Use the piping outlet for jobs required during the steps of 10 REFRIGERANT REPLENISHMENT e g a job of taking in the charge hose Liquid side shutoff valve TE Coking etc Gas side shutoff valve Indoor Outdoor interunit piping Insulation material Piping lead out hole lid Block RENE Liquid side piping N Open a knock hole at ZZ Gas side piping Note After knocking out the holes we recommend you remove burrs in the knock holes and paint the ed
21. 4 kW or over and less than 28 0 kW 22 2 x 1 0 1 2H type No size after branching can exceed the size of any upstream piping Piping between branching areas and each unit If the size of the connection pipe of the indoor unit exceeds that of the branch pipe shown in the table above enlarge the size of the connection pipe near the indoor unit before connecting it 6 English 6 2 Protection Against Contamination when Installing Pipes Protect the piping to prevent moisture dirt dust etc from entering the piping Place Installation period Protection method More than a month Pinch the pipe Outdoor Less than a month i Pinch or tape the pipe Indoor Regardless of the period Note Exercise special caution to prevent dirt or dust when passing piping through holes in walls and when passing pipe edges to the exterior 6 3 Pipe Connection e Be sure to perform nitrogen permutation or nitrogen blow when brazing Refrigerant pipe Location to Regulator be brazed j I TTT Q i lt ANitrogen H Nitrogen Brazing without performing nitrogen permutation or nitrogen blow into the piping will create large quantities of oxidized film on the inside of the pipes adversely affecting valves and compressors in the refrigerating system and preventing normal operation e The pressure regulator for the nitrogen released when doing th
22. Isoliermaterial der Kaltemittelleitungen muss eventuell je nach der Umgebung der W rmeisolierung verst rkt werden Anderenfalls kann sich Taukondensation auf der Oberfl che des Isoliermaterials bilden Falls die Wahrscheinlichkeit gro ist dass das Taukondensation swasser auf den Absperrventilen durch den Spalt zwischen dem Isoliermaterial und der Rohrleitung zur Innenger teseite flie t weil das Au enger t ber dem Innenger t installiert ist oder aus anderen Gr nden treffen Sie geeignete Ma nahmen wie z B das Abdichten der Verbindungen siehe die nachstehenden Abbildungen Bringen Sie bei offener Vorpr gungs ffnung die Abdeckung des Rohrleitungsauslasses an Falls zu bef rchten ist dass Kleintiere durch den Rohrleitungsauslass eindringen dichten Sie den Rohr leitungsauslass nach Abschluss der Schritte unter 10 K LTE MITTEL NACHF LLUNG mit Blockiermaterial vor Ort zu beschaffen ab siehe die nachstehenden Abbildungen Verwenden Sie den Rohrleitungsauslass f r Arbeiten die w hrend der Schritte unter 10 K LTEMITTEL NACHF L LUNG erforderlich sind z B das Einf hren des F llschlauchs Fl ssigkeitsseiten absperrventil TE y Koks usw Gasseiten absperrventil ba bs Innen AuBengerat Verbindungsleitung Isoliermaterial Leitungsanschluss Leitungen Lochabdeckung Block Fl ssigkeitsseite ffnen Sie
23. MUSON Olh ILOCHHAGLOLABLO 01089 HOL OHALSLMHOILXOM LABLIEBEE End GQ 69Jo1 as Oe5P Jejoop ejso anb e opeuoroipuoo Je ep sojopoui so enb epepijqesuodso easnjoxa ens qos eejoap CD 80 Lomylg vonodou U in130360 0 oouo DLO Amnsxono AmmLoupriyn AML DY3LAO OL uo UAngns SU LmLoisynouD ari armylg ED 20 euorzejenip ejsanb ejeju e ino e ojjapow LJojeuorzipuoo au eriiqesuodse ens opos eJeruoip Cr 90 UoIo JeJ26p tJ erouaJo jo aoey sajeno so e opeuoroipuooe alle ep sojapow soy anb pepriqesuodse Balun ns efeq eJeposp ED S0 3yeou Buppezeq uean ezep doseem sjun Bujuomipuooure ap yep preuyfijapioowgueJeA ans snpxe vaba do IIayeiy reepuieA GIN pO one Jepoop ejuasa d vj Jed sas n euuompuoo re p siesedde se enb ajyrgesuodsas ajnas es snos ajepoop CS 0 81 juuuseq Bung asap ap Any eje ebeuy Jap Aapoy erp gep GunyowquejeA e6iureje aulas ne yepe Ca 30 Sejejoi LOIe Jejoap siu Yolym 0 sjepou Buruoqpuoo ye eu jeu Ajrqisuodse ajos sy apun seJepoep ES L0 G11 S3IHLSNANI NDIIVG ONIUV DIH3ASLISLINHONOO 39 3 1WYO4NOJ 30 NOLLYEVTI3G 39 SHZUOdOWWAZ H3UVHV 39 V1SIONNSIVANIANIGHA SALIOW 39 HVASWYS WO ONIH3 T4U3 39 W8191381002 0 34H3lf 8BVE 39 3qvaiWdo4N00 30 0v9v8Y 1030 39 VLINHO3NOO IQ 3NOIZVBVIHOIG 39 QVGIWHO3NOO 30 NOIOVHY 1030 39 NOOISLVUV DISOS AVIS VA 39 LLSONGVTAS O VAVfZI 39 SONNY DIB3SLV LINHONOX 39 Vriovav Dd sval LS Tiglv 39 ALIWHO3NOO 3O NOILV8Y T03Q 39 Vriovuv DI S3LDI
24. Stromversorgungsverkabelung 7 4 Verkabelungsverfahren f r das Ger teinnere d INSPEKTION UND ROHRISOLIERUNG 8 1 Luftdichtheitspr fung Vakuumtrocknung 8 2 W rmeisolierung eeeeeennnnenn 8 3 berpr fen des Ger ts und der Installationsbedingungen eene KONTROLLEN NACH ABSCHLUSS DER ARBEIT 10 K LTEMITTEL NACHF LLUNG nennen TT PROBEEAUEF iir itae orte bte ds 1 EINLEITUNG Dieses Dokument ist eine Installationsanleitung f r das CON VENI PACK von Daikin Bitte lesen Sie diese Anleitung vor der Installation des Ger tes sorgf ltig durch und befolgen Sie die darin enthaltenen Anweisungen F hren Sie nach der Installation einen Probelauf durch um sicherzustellen dass das Ger t ein wandfrei funktioniert und erkl ren Sie dann dem Kunden anhand der Bedienungsanleitung wie das Ger t zu bedienen und zu pfle gen ist Raten Sie abschlie end dem Kunden diese Anleitung zusam men mit der Bedienungsanleitung an einem sicheren Ort aufzu bewahren Diese Anleitung beschreibt nicht die Installation des Innenger ts Siehe dazu die Installationsanleitung des Innenger ts 1 1 Sicherheitshinweise Bitte lesen Sie diese Sicherheitshinweise sorgf ltig durch bevor Sie das CONVENI PACK installieren um korrekte Installation zu gew hrleisten F hren Sie nach Abschluss der Installation einen Probelauf durch um
25. Teile in Abbildung Die bertragungskabel m ssen mindestens 50 mm Abstand von den Starkstromkabeln haben 14 Deutsch Nach Abschluss der Verkabelung sicherstellen dass keine losen Anschl sse unter den Elektroteilen im Steuerkasten vorhanden sind 17 9 11 1 Schutzrohr 2 Die Verkabelung sorgf ltig durchf hren damit die Kabel nicht mit dem Kanal in Ber hrung kommen 3 Bei Verlegung der Hochspannungskabel Stromversorgungska bel Erdleiter und Warnungs Alarm Betriebsausgangskabel auf der linken Seite Anschlie en der lokalen Rohrleitungen Stromversorgungs Klemmenblock X1M X2M Klemmenblock f r Betriebsausgang Erdklemmenblock Bei Verlegung der Hochspannungskabel Stromversorgungska bel Erdleiter und Warnungs Alarm Betriebsausgangskabel auf der rechten Seite 9 Bei Verlegung der Hochspannungskabel Stromversorgungska bel Erdleiter und Warnungs Alarm Betriebsausgangskabel auf der Vorderseite 10 Fernbetriebsschalter Klemmenblock X3M 11 Bei Verlegung der Fernbetriebsschalterkabel durch eine Kabel ff nung 12 Mindestens 50 mm auseinander halten 13 Strebe 14 Die Verkabelung vorsichtig durchf hren damit die Schalliso lierung des Kompressors nicht gel st wird 15 St tze 16 Mit der mitgelieferten Klemme 2 auf der R ckseite der St tze befestigt 17 Mit der mitgelieferten Klemme 2 auf der R ckseite der St tze befestigt ACHTUNG Pr fen Sie nach Absch
26. alle Pole Erdleiter Stromversorgungs Klemmenblock Isolierh lle anbringen Die Stromversorgungskabel f r die Phasen L1 L2 L3 und N jew eils mit den mitgelieferten Klemmen 1 an der Kunststoffklemme sichern 7 Den Erdleiter mit der mitgelieferten Klemme 1 am Stromversor gungskabel Phase N sichern 8 Erdleiter Die Verkabelung so durchf hren dass der Erdleiter nicht mit den Zuleitungen des Kompressors in Ber hrung kommt Anderenfalls kann das erzeugte Rauschen einen schlechten Einfluss auf andere Ger t aus ben 9 Erdungsklemme 10 Wenn zwei Kabel an eine Klemme angeschlossen werden sind diese so anzuschlie en dass die R ckseiten der Crimp kontakte einander zugewandt sind Au erdem ist darauf zu achten dass das d nnere Kabel oben liegt wenn die zwei Kabel gleichzeitig mit der mitgelieferten Klemme 1 am Kunststoffhaken gesichert werden D o0RW Klemme 1 Klemmenblock Crimpklemmen Kabel d nn l ad Kabel dick Kunststoffhaken Vita Anforderungen an Starkstromkreis Sicherheitsvorrichtung und Kabel X1M X4M Klemmenblock Ein Starkstromkreis siehe die folgende Tabelle muss f r den Anschluss des Ger tes vorhanden sein Dieser Stromkreis muss mit den erforderlichen Schutzvorrichtungen z B einem Hauptschalter einer tr gen Sicherung f r jede Phase und einem Fehlerstrom Schutzschalter gesch tzt werden Bei Verwendung von Differenzstromschaltern muss ein
27. and leave charge to eliminate the impact on other devices by reducing noise generated from the inverter device and to prevent leaked current from being charged in the outer hull of the product Do not connect the ground wire to gas pipes sewage pipes light ning rods or telephone ground wires Gas pipes can explode or catch fire if there is a gas leak Sewage pipes no grounding effect is possible if hard plastic pip ing is used Telephone ground wires and lightning rods dangerous when struck by lightning due to abnormal rise in electrical potential in the grounding English Be sure to install an earth leakage circuit breaker This unit uses an inverter so install the earth leakage circuit breaker that be capable of handling high harmonics in order to prevent malfunctioning of the earth leakage circuit breaker itself Earth leakage circuit breaker which are especially for protecting ground faults should be used in conjunction with main switch or fuse for use with wiring Electrical wiring must be done in accordance with the wiring dia grams and the description herein Do not operate until refrigerant piping work is completed If operated before complete the piping work the compressor may be broken down Never remove thermistor sensor or etc when connecting power wiring and transmission wiring If operated with thermistor sensor or etc removed the compres sor may be broken down This product have reversed phase
28. den Rohrleitungen wegen langer Installationsarbeitszeit oder es besteht die Gefahr von Regen wassereindringung in die Rohrleitungen aus anderen Gr nden Dann einen Druck von bis zu 0 05 MPa mit Stickstoffgas f r Vak uumzerst rung aus ben und das Ger t mit einer Vakuumpumpe f r Vakuumtrocknung f r 1 Stunde einem Unterdruck von bis zu 100 7 kPa aussetzen Die Vakuumzerst rung und Vakuumtrocknung wiederholen falls der Unterdruck den Wert von 100 7 kPa oder niedriger nach mindes tens 2 Stunden der Unterdruckerzeugung nicht erreicht Lassen Sie dann den Unterdruckzustand f r 1 Stunde bestehen und pr fen Sie dass die Anzeige des Unterdruckmessers nicht steigt 8 2 W rmeisolierung F hren Sie unbedingt eine W rmeisolierung der Rohrleitungen durch nachdem Sie den Luftdichtheitstest und die Vakuumtrock nung durchgef hrt haben F hren Sie unbedingt eine W rmeisolierung der Fl ssigkeits und Gasleitungen in den angeschlossenen Rohrleitungen durch Anderenfalls kann es zu Undichtigkeit kommen Die Fl ssigkeits und Gasverbindungsrohre m ssen isoliert wer den Anderenfalls kann es zu einem Wasserleck kommen Neh men Sie zur Auswahl der Isolierungsdicke das folgende Diagramm als allgemeine Richtlinie zu Hilfe Minimale Ankunftstemperatur der Fl ssigkeitsleitung 20 C Klimaanlagen Seite 5 C K hlseite Minimale Ankunftstemperatur der Gasleitung 0 C Klimaanlagen Seite 20 C K hlseite Das
29. die Einheit tragen Wenn eine Gummimatte angebracht werden soll ist diese auf der ganzen Fl che des Sockels anzubringen Die H he des Sockels muss mindestens 150 mm ber dem Fu boden betragen Das Ger t mit den Ankerschrauben an seinem Sockel befestigen Je vier im Handel erh ltliche M12 Ankerschrauben Muttern und Unterlegscheiben verwenden Die Ankerschrauben sollten 20 mm weit eingef hrt werden S SEN x Eckloch Unabh ngige Balken Balken verankerung Verankerung verankerung verankerung horizontal vertikal Form des Sockels Ankerschraubenpunkt a 1240 4 15 x 22 5 1102 f 4 V7 E 7 9 Lp 2 3 QW 58 9 9 EQ on o ES LES Qo N ooo ala Ne N omo BIN 9 9 w 22 2 oo 0805 D e NS E 7 V lt T9 9 E Einheit mm Breite des Sockels und Positionen der Ankerschrauben des Sockels Hinweis Bei Dachmontage ist sicherzustellen dass der Dachboden stabil genug ist und alle Arbeiten sind wasserfest zu machen Sicherstellen dass einwandfreier Abfluss im Bereich um die Maschine gew hrleistet ist indem Abflussrinnen um das Funda ment eingerichtet werden Das Au enger t gibt w hrend des Betriebs manchmal Abwasser ab Wenn das CONVENI PACK salzlau Kunstharz genbest ndig oder stark salzlaugen scheiben best ndig ist verwenden Sie Muttern ahh mit Kunstharzscheiben zur Befesti gung des Produkts an den Ank
30. eine ui Vorpr gung bei Hinweis Nach dem Ausschlagen der Vorpr gungen ist es empfehlenswert Grate an den Vorpr gungs ffnungen zu beseitigen und die Kanten und den umliegenden Bereich mit Ausbesserungslack zu lackieren 8 3 berpr fen des Ger ts und der Installations bedingungen berpr fen Sie unbedingt Folgendes F r Elektroinstallateure gt Siehe 7 2 Verfahren f r eingehende Verkabelung 1 Vergewissern Sie sich dass keine fehlerhaften Starkstromkabel oder lockere Muttern vorhanden sind Siehe 7 3 Verfahren f r Stromversorgungsverkabelung 2 Hat sich die Isolierung des Hauptstromkreises verschlechtert Den Isolationswiderstand gem den relevanten rtlichen und nationalen Bestimmungen messen und pr fen ob er ber dem normalen Wert liegt lt F r Rohrleitungsinstallateure gt 1 Sicherstellen dass die Rohrleitungsgr e korrekt ist Siehe 6 1 Wahl des Rohrleitungsmaterials 2 Sicherstellen dass die Isolierarbeiten ausgef hrt worden sind Siehe 8 2 W rmeisolierung 3 Sicherstellen dass keine fehlerhaften K ltemittel Rohrleitungen vorhanden sind Siehe 6 K LTEMITTELLEITUNGEN 16 Deutsch 9 KONTROLLEN NACH ABSCHLUSS DER ARBEIT Vergewissern Sie sich dass die folgenden Arbeiten gem der Installationsanleitung abgeschlossen sind Verrohrung Verkabelung Luftdichtheitspr fung Vakuumtrocknung Installationsarbeit f r Innenger
31. etwaige Fehler festzustellen und erkl ren Sie dem Kunden anhand der Bedienungsanleitung wie das CONVENI PACK zu bedienen und zu pflegen ist Bitten Sie den Kunden die Installations anleitung zusammen mit der Bedienungsanleitung f r sp teres Nachschlagen aufzubewahren Bedeutung der Hinweise WARNUNG und ACHTUNG N WARNUNG Eine Missachtung dieser Anweisungen kann zu K rperverletzungen oder Tod f hren N ACHTUNG Eine Missachtung dieser Anweisungen kann zu Sachbesch digung oder K rperverletzungen f hren die je nach den Umst nden ernsthaft sein k nnen berm ige K ltemittelmenge in einem geschlossenen Raum kann zu Sauerstoffmangel f hren Verwenden Sie nur vorgeschriebenes Zubeh r und Teile f r die Installationsarbeiten Bei Verwendung ungeeigneter Teile besteht die Gefahr dass das Ger t herunterf llt oder ein Wasserleck elektrischer Schlag oder Brand verursacht wird Installieren Sie das CONVENI PACK auf einem Fundament das stark genug f r das Gewicht des Ger ts ist Ein Fundament von unzureichender Tragf higkeit kann zu Herun terfallen und Unf llen mit Verletzungen f hren F hren sie die vorgeschriebenen Installationsarbeiten nach Ber cksichtigung starker Winde Wirbelst rme oder Erdbeben aus Anderenfalls besteht die Gefahr dass das Ger t herunterf llt und Unf lle verursacht Stellen Sie sicher dass ein getrennter Betriebsstromkreis f r diese Anlage vorhanden ist und dass elektrisch
32. following figure do not apply contact your dealer or Daikin directly English lt When installed as a single unit gt When installed in serial gt Pattern 1 NOTE Pattern 1 NOTE ANIMAN 1 On 32 ge o EE S ss S gS s A I 8i gs DO ooo 2 L e I 2 i 8 g 210 210 MES gt 10 gt 10 Ss Front S 22 gt 20 pe CUT 320 332 Font A ES t sihe 1 1 R S5 Side 135 L____Frontside____ 35 Pattern 2 NOTE 22 Pattern 2 NOTE 23 A BH e s 007 i 25 fee 383 L 33 1 N ea HO IC ate i Bs i Alo gt 50 gt 50 ol 8 a 50 250 o 8 Rar x BB sto ao 8 2 side 125S Front side I 58 EET S Lo IR _____ 35 x No limit to wall height Pattern 3 Pattern 3 E TY ue ae A E Y OMA 3 No limit to 8l OQ we I GO IO i gt 200 gt 200 I 2400 A _ gt 400 Front side Front side NOTE For Patterns 1 and 2 Wall height for front side no higher than 1500 mm Wall height on the suction side no higher than 500 mm Wall height for sides no limit e Ifthe height is exceeded the above calculate h1 and h2 shown in the figure on next page and add h1 2 to the service space of front side and h2 2 to the service space of suction side
33. for which the path to the heat exchanger has been routed so that the flow of refrigerant is from bottom to top Units with copper tubing or fan corrosion Units that may be contaminated with foreign matter such as rub bish or other dirt English 6 1 Selection of Piping Material Make sure that the inner side and outer side of the piping used is clean and free of contaminants such as sulphur oxide dust chips oil and fat and water It is desirable that the maximum oil adhesion in the piping is 30 mg per 10 m Use the following type of refrigerant piping Material Seamless phosphorus deoxidized copper tube C1220T O for a maximum outer diameter of 15 9 mm and C1220T 1 2H for a mini mum outer diameter of 19 1 mm Refrigerant piping size and wall thickness Decide the size and thickness from the following table This product uses R410A The withstand pressure of O type may be insufficient if it is used for piping with a minimum diameter of 19 1 mm Therefore be sure to use 1 2 H type with a minimum thickness of 1 0 mm If O type is used for piping with a minimum diameter of 19 1 mm a minimum thickness of 1 2 mm will be required In that case be sure to perform the blazing of each joint Be sure to perform piping work within the range specified in the following table Ds JA G A2 E Liquid piping Refrigerant piping length a g a2 e2 Gas ping
34. length 130m Note Be sure to insulate the mating equipment Remote operating switch wiring connections When installing a remote operating switch clamp as indicated by the following diagram Secure remote operating switch wiring to the resin block using a clamp field supply X3M wire specifications 0 75 1 25mm Max wiring length 130m AN CAUTION For Remote switch use non voltage contact for microcurrent not more than 1mA 12VDC e If the remote operating switch will be used to start and stop the unit set the operating switch to REMOTE Electric wire thickness lt Precautions for Terminal Connections gt Be sure to use ring type crimp style terminals provided with insu lation sleeves Use specified electric wires for the wiring and secure the wiring so that external force will not be imposed on the terminal block Crimp style terminal Power wire SOS Insulating sleeve Use an appropriate screwdriver to tighten the terminal screws Small sized screwdriver will damage the screw heads and cannot tighten the screws properly Do not tighten the terminal screws in excess otherwise the screws may be damaged Referto the following table for the tightening torque values of the termin
35. oder anderen Bereichen ausgelaufen ist da Erfrierungsgefahr besteht Lassen Sie nicht zu dass Kinder auf das Au enger t klettern und stellen Sie auch keine Gegenst nde auf das Ger t Es kann zu Verletzungen kommen falls das Ger t sich lockert und herunterf llt Deutsch Erden Sie das Ger t nicht an einer Gas oder Wasserlei tung einem Blitzableiter oder der Erdleitung eines Tele fons Falsche Erdung kann zu elektrischen Schl gen oder Brand f hren Ein starker Stromsto von einem Blitzschlag oder anderen Quel len kann eine Besch digung des CONVENI PACK verursachen Installieren Sie unbedingt einen Fehlerstrom Schutzschalter Wenn keine Erdschluss Sicherung installiert ist besteht die Gefahr von elektrischen Schl gen oder Feuer ACHTUNG Installieren Sie die Ablaufleitungen nach den Anweisungen in die ser Installationsanleitung um einwandfreies Ablaufen zu gew hr leisten und isolieren Sie die Leitungen um Kondensation zu verh ten Falsche Verlegung der Ablaufleitungen kann zu Wasserlecks und Sachsch den im Innenraum f hren Installieren Sie das Innen und Au enger t sowie die Stromver sorgungs und Verbindungskabel in mindestens 1 m Abstand von Fernsehger ten oder Radios um Bildst rungen oder Rauschen zu vermeiden Je nach der einfallenden Signalst rke ist ein Abstand von 1 m eventuell nicht ausreichend um Rauschen zu vermeiden Installieren Sie das CONVENI PACK nicht an f
36. protection detector that only works when the power is turned on Ifthere exists black out orthe power goes on and off which the product is operating attach a reversed phase protection circuit Running the product in reversed phase may break the compressor and other parts Attach the power wire securely Introducing power with a missing N phase or with a mistaken N phase will break the unit Never connect the power supply in reversed phase The unit can not operate normally in reversed phase If you connect in reversed phase replace two of the three phases Make sure the electrical unbalance ratio is no greater than 2 If it is larger than this the unit s lifespan will be reduced Ifthe ratio exceeds 4 the unit will shut down and an malfunction code will be displayed on the indoor remote controller Connect the wire securely using designated wire and fix it with attached clamp without applying external pressure on the termi nal parts terminal for power wiring terminal for transmission wir ing and earth terminal Install a switch that allows you to switch all poles from the main power supply 10 English
37. refrigerant filling e Pay attention to the rotation of the fan whenever the front panel is opened while working The fan can rotate continuously for a while after the outdoor unit stops operating Refrigerant Replenishment Work MN CAUTION Refer to the Operation Method of Shutoff Valves for the control method of the shutoff valves Never replenish liquid refrigerant directly from a gas line Liquid compression may cause the compressor to fail Refer to the Service Manual for instructions on additional refriger ant charging when indoor units are connected only to the air con ditioning equipment side or only to the refrigeration equipment side English 15 When the only indoor unit connected is an air conditioner when the showcase is not connected to the air conditioning side refer to the Service Manual for instructions on additional refrigerant charging 1 The refrigerant must be noted for this product Calculate the amount of refrigerant replenishment according to the label for the calculation of the amount of refrigerant replenishment Procedures for calculating refrigerant charge amounts are described in page 18 2 Take the following procedure for refrigerant replenishment Refer to 8 1 Air Tight Test Vacuum Drying for the connection of the refrigerant cylinder 1 Turn on the indoor unit and control panel Do not turn on the outdoor unit 2 Replenish refrigerant from the service port of the
38. t Installationsarbeit f r Zusatzger t Beim Anschluss des Zusatzger t 10 K LTEMITTEL NACHF LLUNG A F r den K ltemitteltechniker Verwenden Sie R410A f r K ltemittel Nachf llung Auf die R410A K ltemittelflasche ist ein rosafarbener G rtel aufge malt SAN Warnung A Stromschlagwarnung Schlie en Sie den Steuerkastendeckel einwandfrei bevor Sie die Stromversorgung einschalten Bevor Sie die Stromversorgung einschalten pr fen Sie durch die Sicht ffnung auf der linken Seiten des Steuerkastendeckels dass der Betriebsschalter RUN auf OFF steht Steht der Betriebsschalter RUN auf ON kann der L fter rotieren Verwenden Sie eine isolierte Stange um die Drucktasten durch die Inspektionst r der EL COMPO BOX zu bet tigen Da diese Arbeit in eingeschaltetem Zustand durchgef hrt werden muss besteht die Gefahr eines elektrischen Schlags bei Ber hrung von stromf hrenden Teilen berpr fen Sie die LED Anzeigen auf der Platine A1P des Au enger ts durch die Sicht ffnung auf der rechten Seite des Steuerkastendeckels nachdem Sie das Au enger t einge schaltet haben siehe die Abbildung Der Kompressor l uft nach dem Einschalten des Au enger ts und des Klimaanlagen Innenger ts etwa 10 Minuten lang nicht H2P erlischt bei Betriebsbereitschaft des Systems H3P blinkt weiter Sicht ffnung rechte Seite obere rechte Seite des Schaltkastens
39. und die Ladung zur cklassen um die Auswirkung auf andere Ger te zu eliminieren indem das von einem anderen Wechselrichter erzeugte Rauschen reduziert wird und um das Aufladen der Au enh lle des Produkts mit Leckstrom zu ver h ten 10 Deutsch Den Erdleiter nicht an Gasrohre Abwasserrohre Blitzableiter oder Telefon Erdleiter anschlie en Gasrohre Diese k nnen im Falle eines Gaslecks explodieren oder in Brand geraten Abwasserrohre Bei Verwendung von Hartplastikrohren ist kein Erdungseffekt m glich Telefon Erdleiter und Blitzableiter Gef hrlich bei Blitzschlag wegen abnormalen Anstiegs des elektrischen Potentials in der Erdung Unbedingt einen Fehlerstrom Schutzschalter installieren Da dieses Ger t einen Wechselrichter verwendet muss ein Fehlerstrom Schutzschalter installiert werden der hohe Ober schwingungen verarbeiten kann um eine Funktionsst rung des Fehlerstrom Schutzschalters selbst zu verh ten Ein Fehlerstrom Schutzschalter der speziell f r den Schutz von Masseschluss geeignet ist sollte in Verbindung mit dem Hauptschalter oder einer Sicherung f r die Verkabelung verwen det werden Die elektrische Verkabelung muss gem den Schaltpl nen und der Beschreibung in dieser Anleitung durchgef hrt werden Nicht in Betrieb nehmen bis die K ltemittelverrohrung abge schlossen ist Wird die Anlage in Betrieb genommen bevor die Verrohrung abgeschlossen ist kann der Kompressor besch digt werden
40. unit This circuit must be protected with the required safety devices e a main switch a slow blow fuse on each phase and an earth leakage circuit breaker When using residual current operated circuit breakers be sure to use a high speed type 1 second or less 200mA rated residual operating current Use copper conductors only Use insulated wire for the power cord Select the power supply cable type and size in accordance with relevant local and national regulations Specifications for local wiring are in compliance with IEC60245 Use wire type HO5VV when protected pipes are used Use wire type HO7RN F when protected pipes are not used Minimum Recom Phase and ips Voltage circuit mended frequency amp fuses LRYEQ16AY1 3 50Hz 380 415V 35 2A 40A Point for attention regarding quality of the public electric power supply This equipment complies with respectively m EN IEC61000 3 11 provided that the system impedance Z4ys is less than or equal to Zmax and m EN IEC61000 3 12 provided that the short circuit power Sse is greater than or equal to the minimum Sse value at the interface point between the user s supply and the public sys tem It is the responsibility of the installer or user of the equipment to ensure by consultation with the distribution network operator if nec essary that the equipment is connected only to a supply with respec tively E Z7 s less than or
41. use to the sealing part e Be sure to tighten the cap securely after the work Refer to Oper ation Method of Shutoff Valves for the tightening torque of the cap Cap Sealing part Not apply a screw Screw thread lock agent Apply a screw lock agent MN CAUTION Apply a screw lock agent to the valve cover mount and the screw thread of the service port Otherwise dew condensation water will intrude inside and freeze Therefore refrigerant gas leakage or a compressor malfunction may result from the cap deformation or damage 3 Connecting refrigerant piping to outdoor units If connected to the front Remove the shutoff valve cover to connect 3 Gas side shutoff valve 2 Gas side shutoff valve Refrigerator Air conditioner 4 Liquid side shutoff valve Refrigerator 1 Liquid side shutoff valve Air conditioner Brazing Liquid side accessory pipe 1 Liquid side accessory pipe 2 Gas side accessory pipe 1 Gas side accessory pipe 2 When connected at lateral side bottom Remove the knock hole on the bottom frame and route the piping under the bottom frame 3 Gas side shutoff valve 2 Gas side shutoff valve Refrigerator Air conditioner 4 Liquid side shutoff valve 1 Liquid side shutoff valve Refrigerator Air conditioner quid side accessory pipe 3 iquid side accessory pipe 4 Gas side accessory pipe 4 Knock hole Punch the k
42. zu verh ten Manometer verwenden Sie ein f r R410A dediziertes F llschlauch Mehrzweck Manometer und einen F llschlauch F r R410A und R407C dedi zierte Werkzeuge haben unterschiedliche Schraubenspezifikationen Achten Sie mit gr ter Sorgfalt darauf dass kein Pumpen l in das System zur ck flie t w hrend die Pumpe nicht in Betrieb Vakuumpumpe ist Verwenden Sie eine Pumpe die eine Evakuierung bis herunter auf 100 7 kPa 5 Torr bzw 755 mmHg erm glicht Gas f r Luftdich theitstest Luftdichtheit Setzen Sie den Hochdruckteil des Systems Fl ssigkeitsleitung einem Druck von 3 8 MPa 38 bar und den Niederdruckteil des Systems Gasleitung dem Genehmigungsdruck 1 des Innenger ts vor Ort zu beschaffen ber den Wartungsanschluss 2 aus den Genehmigungsdruck nicht berschreiten Das Sys temist als einwandfrei zu betrachten wenn kein Druckabfall ber einen Zeitraum von 24 Stunden festgestellt wird Falls Druckabfall auftritt das System auf Leckstellen berpr fen und reparieren Vakuumtrocknung Schlie en Sie eine Vakuumpumpe f r mindestens 2 Stunden an die Wartungsanschl sse der Fl ssigkeits und Gasleitungen an und setzen Sie das Ger t einem Unterdruck von bis zu 100 7 kPa oder niedriger aus Lassen Sie dann das Ger t mind estens 1 Stunde lang einem Unterdruck von 100 7 kPa oder niedriger ausgesetzt und pr fen Sie dass die Anzeige des Unter druckmessers nicht ste
43. zu vermeiden 2 Entfernen der Quetschleitung Wenn K ltemittelleitungen an das Au enger t angeschlossen wer den sind die St tzrohre wie im folgenden Verfahren zu entfernen Siehe Funktionsweise des Absperrventils zur Handhabung des Absperrventils Fl ssigkeits und Gasseiten absperrventile Wartungsanschluss Vergewissern Sie sich dass kein K ltemittelgas ausstr mt nach dem Ventildeckel und Kappe fest angezogen worden sind Anzugsmoment berpr fen Sie anhand der folgenden Tabelle die Gr en der vom jeweiligen Modell verwendeten Absperrventile sowie die Anzugsmo mente der entsprechenden Absperrventile Absperrventilgr en Verfahren 1 Stellen Sie sicher dass das Absperr ventil geschlossen ist Verfahren 4 Schmelzen Sie das L Verfahren 2 Schlie en Sie einen F llschlauch an den Wartungsanschluss des Fl ssigkeits seiten und des Gasseitenabsperr ventils an und entfernen Sie das Gas material mit einem Brenner aus der Quetschleitung und entfernen Sie die Quetsch leitung gro nachdem das Gas aus der Quetsch leitung abgelassen wurde Quetschleitung Leitung auf der Produktseite E CY Wartungsanschluss Leitungen vor Ort Quetschleitung gro Quetschleitung klein Abschneiden Yo v uU x F llschlauch Verfahren 3
44. 5 2 1 7 From 15kW to less than 20kW 4 6 2 3 20kW or more 5 9 3 0 1 Case of showcase the condition of capacity evaporating temper Note ature Refrigeration 10 C Frozen 35 C 2 Case of blower coil the condition of capacity is 10 C Ta Table 2 The amount of refrigerant of the indoor unit for air condition ing HP Kinds of 2 01 25 3 2 4 0 5 0 8 0 10 0 indoor unit Round flow cassette type FXFQ 0 5 0 9 0 9 0 9 1 0 Double flow cassette type FXCQ 0 5 0 7 0 8 1 1 Ceiling built in FXSQ 0 3 0 6 0 5 1 0 1 0 Ceiling mounted duct type FXMQ 0 5 1 2 1 2 2 1 2 4 Ceiling suspended type 0 8 FXHQ Ceiling suspended cassette 0 9 14 type FXUQ i i Calculate for each unit Figure 1 HL A few Qi Ua flow i Sealed state o Bubbles come out at all times Shortage of refrigerant x i 18 English DAIKIN LRYEQ16AY1 E CONVENI PACK Installationsanleitung INHALT WARNUNG 1 EINLEITUNG s 1 Beauftragen Sie Ihren H ndler oder qualifiziertes Personal mit ES der Installation der Anlage i EE cua coop Versuchen Sie nicht das CONVENI PACK selbst zu installie 1 8 Entsorgungsanforderungen ens 3 ren Eine unsachgem e Installation kann zu Wasserlecks 2 VOR DER INSTALLATION e ees 3 elektrischen Schl gen oder Brand f hren 2 1 Standardzubeh r es 3 Di
45. ABIERW uaeyepnou gp uea ueDuijedeq ap BijsuloxueaJeA0 yg H SLME BLA wyteat auo Z 3 euesjeuiuiejseq Ployuay 16 Zp sep Suogeindys xne juauiguuJojuoo gg ejojenou JJenejsen QZ 31 U8JOXJJA Bue Lap uayiuuosio Uap geuieb zo yop nluenajgodn qo 6 noL jo suoisino d ay Buimo jo LO 68 2 SEE0YNA Ot Z G 09N3 3 Sof d3jAlgo On arl DAm brino IpLAnoIoUOTIOUGX n Losgounodu Aui oun acmiomonox ojodndAAg oyyo Li o ouniodu ojognoyoxo 0 oi ar namdrino was 40 ejje eyruuojuoo ur Nesn oue uen ayo oped e omyewou asopejeo e ojueuunsop ijone o s puepuers ajuanas SOuoI99n4sul seqsenu uoo opjanoe ep sopezijn veas enb ediueis s onneuJou s ojueuinoop s ono n s ewuou s azuembis s e uoo pepiuuojuoo ue upisa G0 sailonusul azuo nswoyussJeno jyrruqa uap om az ep ap eemuoon do uliz usjueuunoop epuepulq aiepue Jaaui jo ugs jo ua uuiou epuefjo ep uuojuoo yo Suoionjsul sou e juaurguuojuoo sosiln juetos snb juejne nod s yreuuou s jueunoop sjane no s euuou xnejej e seuuojuoo juos 0 uepiaM yzjesebula uaBunsiamuy uaiasun gewab als gep Bunzjassneio Jap 19un ueyosuds uayods ua uajuauimyop Japo jueuimyopuuov uejepue waua sapo us uuoy Lepus jo uap iep Z0 sSuoHorUjsul JNO Yj 99uepjo92e ul pasn aye esauj yey pepinoid s juewnoOp an reunou Jayjo 10 s psepuejs Bumojjo au ym Ajluuojuos ur are Lg 96 LAVeoxa917 u 3 LAvoro3AH1 O HOLEBEE GalTiHOLOEH HOLMOOHLO wIado oN x exftfeos aodeHoviitiHoy
46. DAIKIN INSTALLATION MANUAL Installation manual CONVENI PACK Installationsanleitung CONVENI PACK Manuel d installation CONVENI PACK Manual de instalaci n CONVENI PACK Manuale di installazione Outdoor Unit CONVENI PACK LRYEQ16AY1 E Installatiehandleiding CONVENI PACK Manual de instalac o CONVENI PACK ueder eze8 0es exeso nx ey IUSIN MeZexeN zL p c pig 161092 epaun GLTSFIULSNAINI NDIVA 1016 bipjuipuapabap yeJejo njwnjo uepuyjere lt g gt 3196 euisexupues 2 eA Iq Ifipinulaq ep ev cz lt gt WyuagpaAso s pejs 0d e tf A gUeponn ooq ONE y tr 9 MENYILS Je Eueyses ueuinfgug weleAnIzod lt g gt ISOS un y SIIPEJOU by EZ LOLOPZCOSO lt gt brexyrueg jebed lt g gt eisdudsnu reweibie diey 41 vr eyAjejsnu diey zz N8 Sd3 PIejureug ANL 2 tremendo OHOBURO B 10 OHLG1HKOUU 600c v0 E9 70 3OL NDIIVG OHGHANO V V 8 OHAKOUEN ODIEN Z eapoadsaJ ajejueuuepueuie no IojejoellQ 9 weymeudod iukzsfeiuzod z 1 yesezexjopuei weseysopoui so e Nafueui 9 ouefuefiuuzi af oyey eouieftus c juguz waujeyd py Euingojnnu yeno au uny euistejjas efoAn yaq e jeBuupue ayejalo pau BAWA ZL eDuupue eubejeJo pow Aii LL JeBuupuee ajeues paul jeAeliq QL JeyeuneuoA eAuayey Siuunsibeq sz juauz uioujejd A eoiuJeuis yz sounfeuipjided oj un SeAjeiQ z jeu pjided ns as
47. Innenseite der Wartungs blende Contains fluorinated greenhouse gases covered ILLI by the Kyoto Protocol 4 1 werkseitige E K ltemittelbef llung des R410A O kg 1 Produktes siehe N o ff Jk Typenschild der Einheit g TO L____ 72 2 zus tzliche am Montageort O o a1 M kg 3 gesamte 7 3 Kaltemittelbefiillung 6 5 4 Enth lt fluorierte Treibhausgase die durch das Kyoto Protokoll abgedeckt werden bef llte K ltemittelmenge 5 Au enger t 6 K ltemittelzylinder und Sammelleitung f r die Bef llung GENEHMIGUNGSDRUCK Da der Genehmigungsdruck bei 3 8 MPa oder 38 bar f r R407C Einheiten bei 3 3 Pa oder 33 bar liegt muss die Wanddicke der Lei tungen sorgf ltig entsprechend der lokalen und nationalen Gesetzgebung gew hlt werden Deutsch 1 3 Entsorgungsanforderungen Die Demontage des Ger ts sowie die Behandlung von K ltemittel l und anderen Teilen m ssen gem der relevanten rtlichen und nationalen Gesetzgebung erfolgen 2 VOR DER INSTALLATION ACHTUNG Nehmen Sie bei der Installation des Innenger ts dessen Installa tionsanleitung zur Hand Sonderzubeh rteile sind f r die Installation des Produkts erforderlich Siehe die Informationen ber Sonderzubeh r 2 1 Standardzubeh r Die folgenden Zubeh rteile werden mitgeliefert Die Abbildung zeigt den Aufbewahrungsort der Zubeh rteile Hinweis Werf
48. LLUV 39 1VZOXIVTIAN 53S0 1313493N 39 M SON3GV INSN O VAVEZI 39 DAIKIN CONVENI PACK Installation manual LRYEQ16AY1 E CONTENTS 1 FIRST OF ALL treten utente sans 1 1 1 Safety Precautions sess 1 1 2 Special Notice of Product 2 1 3 Disposal Requirements seeseeeeeeene 2 2 BEFORE INSTALLATION 2 2 1 Standard Supplied Accessories ssssss 2 2 2 Example of System Contiguration 3 2 3 Indoor Unit Constraints eee 3 3 SELECTION OF LOCATION eeeeeeeeeneeneneneen 3 4 HANDLING THE UNIT sseseeeeeeeeeeenen emen 4 5 PLACING THE UNIT 5 6 REFRIGERANT PIPING eseese 5 6 1 Selection of Piping Material eeees 6 6 2 Protection Against Contamination when Installing Pipes omoocormonecrnonorosnnoriconcccnrncrncanono 7 6 3 Pipe Connection 6 4 Drier Installation 6 5 Connecting the Refrigerant Piping eeeeeeeeeeees 7 7 FIELD WIRING seen 9 7 1 Example of Wiring Entire System is 7 2 Procedure for Incoming Wiring esses 11 7 3 Procedure for Power Supply Wiring 12 7 4 Procedure for Wiring Inside Units 8 INSPECTION AND PIPE INSULATION 8 1 Air Tight Test Vacuum Drying seses 8 2 Thermal Insulation Work
49. NYUIVSHO3 39 DNIH3 0183535 13014340 39 lt gt Opeayities jo U09 opienoe ap D eye IN pouueu g 10d ojueureAjisod opeiojeA so v ue ooojqelso 3S OWO Gf 18 je Jesepuna janisod Do vi ugue WOS OF 9 aioavetetan OHOBLIO lt gt WanHeMad WiSHRUBLHOUO 98101981000 8 M V BOHBEBY NEN 60 lt 9 gt VELJUN lswoyusdleno lt g gt 100p pjeepioooq JANISO Ua v U Deui SIEOZ po lt 9 gt JEOYIHAd ne jueueuiJojuoo lt g gt 9 OPEIN O WOO OPIOOE ep lt B gt ep Osod Jed jueujeAnisod anjeng je v suep yap anb 9 gg J898Jed 0 02 9 lt Y gt Ule opioejeqejsa OWOD e gf 9 oxuliouo1ot o ari pAm rino lt g gt 01 QUO DAILIY ID13AION 103 lt y gt 010 I013 dogox mio Z0 lt 9 gt ioyuuez gewed yeuneq AiSod lt g gt UOA pun Junjeejne v Jap ui AM 20 lt 9 gt ejeatyue au 0 Buppioooe lt gt OJBAL LIS opuooes go Ep g Aq Ajann sod paBpn pue ev u mo jas se 10 aueuengsod ojeopnf a ev iou oJeauap 99 MINSNHAKOLOLI 9 W48121681009 8 60 We OJSIAGId O o9 opiooe ep 80 A01 Nn33piDio AML Lod ari 20 Wepaneid ewun ul gi mpeg iueiueiwouejsod z erupoDz Z ayesejo unf n euuejnsoy ununq SZ x z e Nanoy 9L eIueAouejsn ON BABIZIPO HZ ewegpaupo euieid gy Jed iuorzuoseid oj opuooos 90 sepyropou se seqiseud jo ojeAat ez insidpayd juanouejsn juazipop ez pL 9p sauoroisodsip sej opualnbis G0 thwemiajed hyejsonu srueye zz BISH
50. Ozonschicht und ver ringert nicht den Schutz der Erde vor sch dlicher Ultraviolett strahlung R410A kann den Treibhauseffekt geringf gig verst rken falls es freigesetzt wird Da R410A ein gemischtes K ltemittel ist muss das erforderliche zus tzliche K ltemittel in seinem fl ssigen Zustand eingef llt werden Wird das K ltemittel in gasf rmigem Zustand eingef llt ver ndert sich seine Zusammensetzung und das System funktio niert nicht einwandfrei F hren Sie unbedingt eine K ltemittel Nachf llung durch Siehe 9 KONTROLLEN NACH ABSCHLUSS DER ARBEIT und den Aufkleber mit Anweisungen zum Nachf llen von K ltemittel auf der Abdeckung des Steuerkastens Wichtige Informationen hinsichtlich des verwendeten K ltemit tels Dieses Produkt enth lt fluorierte Treibhausgase die durch das Kyoto Protokoll abgedeckt werden Lassen Sie Gase nicht in die Atmosph re ab K ltemittel Typ R410A GWP wert 1975 GWP Treibhauspotential Die Werte sind angegeben in F Gasvorschriften EC No 842 2006 Anhang Teil 1 und 2 Bitte mit abriebfester Tinte ausf llen W O die werkseitige K ltemittelbef llung des Produktes W 2 die am Montageort bef llte zus tzliche Kaltemittelmenge und E 0 die gesamte K ltemittelbef llung am K ltemittelbef lletikett das im Lieferumfang des Ger tes enthal ten ist Das ausgef llte Etikett muss in der N he der K ltemittel Einf ll ff nung angeh ngt werden z B auf der
51. Rest strom des Hochgeschwindigkeitstyps 1 Sekunden oder weniger mit einer Nennstromst rke von 200 mA verwendet werden Verwenden Sie nur Kupferleiter Verwenden Sie ein isoliertes Kabel als Netzkabel W hlen Sie Typ und Gr f3e des Stromversorgungskabels entsprechend den relevanten lokalen und nationalen Bestimmun gen aus Die Vorschriften f r die lokale Verkabelung entsprechen IEC60245 e Kabeltyp HO5VV verwenden wenn gesch tzte Rohre benutzt werden Kabeltyp HO7RN F verwenden wenn keine gesch tzten Rohre benutzt werden Minimale EMP Phase und fohlene Spannung Strom Frequenz x Sicherun st rke gen LRYEQ16AY1 43 50Hz 380 415V 35 2A 40A Wichtiger Punkt hinsichtlich der Qualit t der ffentlichen Stromversorgung Dieses Ger t entspricht jeweils m EN IEC 61000 3 11 vorausgesetzt dass die Systemimpedanz Zsys kleiner oder gleich Zmax ist und m EN IEC 61000 3 12 vorausgesetzt dass der Kurzschlussstrom Sg gr er oder gleich dem minimalen S Wert am Schnittstellenpunkt zwischen der Stromversorgung des Benutzers und dem ffentlichen System ist Der Installateur oder Benutzer des Ger ts ist daf r verantwortlich gegebenenfalls durch Absprache mit dem Leitungsnetzbetreiber zu gew hrleisten dass das Ger t nur an eine Stromquelle angeschlossen wird bei der jew eils W Z ys kleiner oder gleich Zmax und W S gr er als oder gleich dem mini
52. S AFTER WORK COMPLETION The refrigerant R410A requires strict cautions for keeping the sys tem clean dry and tight Read the chapter REFRIGERANT PIPING carefully and follow these procedures correctly A Clean and dry Foreign materials including mineral oils such as SUNISO oil or moisture should be prevented from getting mixed into the system B Tight Take care to keep the system tight when installing R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection against harmful ultraviolet radiation R410A can contribute slightly to the greenhouse effect if it is released Since R410A is a mixed refrigerant the required additional refrig erant must be charged in its liquid state If the refrigerant is charged in a state of gas its composition changes and the system will not work properly Be sure to perform refrigerant replenishment Refer to 9 CHECKS AFTER WORK COMPLETION and the label of instructions on refrigerant replenishment on the cover surface of the control box Important information regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent gases into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Values are indicated in F gas regulations EC No 842 2006 Annex l Parts 1 and 2 Please fill in with indelible ink E the factory ref
53. Weniger als ein Monat Quetschen oder Ungeachtet des Zei Umwickeln des Rohrs Innen traums Hinweis Lassen Sie besondere Vorsicht walten wenn Sie Rohrleitungen durch L cher in W nden f hren oder Rohrenden nach drau en ver legen um das Eindringen von Schmutz oder Staub zu vermeiden 6 3 Leitungsanschl sse F hren Sie beim L ten unbedingt Stickstoffpermutation oder Stickstof feinblasung durch K ltemittelleitung L tstelle ver Q lt Sticksto IHR Umwicklung _ Handy Ventil Stickstoff L ten ohne Stickstoffpermutation oder Stickstoffeinblasung in die Rohrleitungen f hrt zur Bildung gro er Mengen von oxidiertem Film auf der Innenseite der Rohre wodurch die Ventile und Kom pressoren im K hlsystem beeintr chtigt werden und normaler Betrieb verhindert wird Der Druckregler f r die Stickstoffsp lung w hrend der L tarbeit ist auf 0 02 MPa einzustellen ca 0 2 kg cm eine leichte Brise ist auf der Wange zu sp ren Hinweis Verwenden Sie keine Oxidationsinhibitoren beim L ten der Rohr verbindungen R ckst nde k nnen die Rohre zusetzen und zu einer Besch digung der Anlage f hren 6 4 Installation eines Trockners ACHTUNG Dieses Produkt erfordert die Installation eines Trockners am Fl s sigkeitsrohr vor Ort Der Betrieb des Ger ts ohne installierten Trockner kann zu einem Ausfall der Anlage f hren W hle
54. al screws Take out the earth wire from the notch of the cup washer and lay the wire carefully so that other wires will not be caught by the washer Otherwise the earth wire may not contact sufficiently and the earthing effect of the wire may be lost e Do not finish strand wire with solder Cup washer Screw size Tightening torque Nem M8 Power supply terminal block pply T M8 Earth M4 X2M 2 39 2 91 M3 5 X3M 0 79 0 97 7 4 Procedure for Wiring Inside Units Referring to the following figure secure and wire the power and transmission wiring using the accessory clamp 1 2 and 3 Laythe ground wire so that it will not come in contact with the lead wires of the compressor Other equipment will be adversely affected if the ground wire comes in contact with the lead wires of the compressor Make sure all wiring do not contact to the pipes hatching parts in the figure The transmission wiring must be at least 50 mm away from the power wiring After wiring work is completed check to make sure there are no loose connections among the electrical parts in the control box 6 13 HER 1 GI 2c 3 14 j 6 EOS 4 Conduit Na Perform wiring carefully so that the wiring will not come in contact with the p
55. als from outdoor unit This will ensure the smooth returning of oil in the piping slanting upward 7 FIELD WIRING To Electric Engineering Contractors Be sure to install an earth leakage breaker The product incorpo rates inverter equipment In order to prevent the malfunctioning of the earth leakage breaker make sure that the earth leakage breaker withstands harmonic interference Do not operate the CONVENI PACK until refrigerant piping work is completed or otherwise the compressor will malfunction Do not remove any electrical components such as thermistors or sensors when connecting power supply wires or transmission wires The compressor may malfunction if the CONVENI PACK is operated with such electrical components removed N CAUTION All field wiring and components must be installed by a licensed electrician and must comply with relevant local and national reg ulations Be sure to use a dedicated power circuit Never use a power sup ply shared by another appliance Never install a phase advancing capacitor As this unit is equipped with an inverter installing a phase advancing capacitor will not only deteriorate power factor improvement effect but also may cause capacitor abnormal heating accident due to high frequency waves Only proceed with wiring work after blocking off all power Always ground wires in accordance with relevant local and national regulations This machine includes an inverter device Connect earth
56. amage the wiring English 2 Removing Pinch Piping In the case of connecting refrigerant piping to the outdoor unit remove the span piping as in the following procedure Refer to Operation method of shutoff valve for handling of the shutoff valve Liquid side and gas side shutoff valves Service port Procedure 1 Confirm the shutoff valve is closed Procedure 2 Connect a charge hose to the service port of the liquid side and gas side shutoff valves and remove the gas from the pinch piping Procedure 4 Melt the brazing material with a burner and remove the pinch piping large after the gas in the pinch piping is discharged Pinch piping item Charge hose z O Service port On site piping Pinch piping Large Pinch piping Small Piping on product side Cut off v P A u Procedure 3 Cut off the pinch piping small with an appropriate tool such as a pipe cutter and open the cross section to check that there is no residual oil Note If oil comes out of the cross section cut off the pinch piping large with a pipe cutter and remove the pinch piping N WARNING Disconnect the pinch piping after collecting the refrigerant gas in the piping The piping may be blown off and injury may result by melting the brazing filler metal unless the
57. and Freezer The design pressure for the indoor unit is 2 5 MPa or more Install an R410A mechanical thermostatic expansion valve on each indoor unit Insulate the feeler block of the mechanical thermostatic expan sion valve Install an R410A solenoid valve on the primary side of the mechanical thermostatic expansion valve Max operating differ ential pressure of 3 5 MPa 35 bars or over described above for each indoor unit Install a filter on the primary side of the solenoid valve described above for each indoor unit Determine the filter mesh count based on the size specified by the solenoid valve and mechanical ther mostatic expansion valve being used Route the path to the indoor unit heat exchanger so that the flow of refrigerant is from top to bottom When installing a number of indoor units be sure to install them at the same level Use either off cycle defrosting or electric heater defrosting as the defrosting type Hot gas defrosting models cannot be used 3 SELECTION OF LOCATION Select a location for installation that meets the following conditions Get the customer s permission 1 2 3 There is no danger of fire due to leakage of inflammable gas Select the location of the unit in such a way that neither the dis charged air nor the sound generated by the unit disturb anyone The foundation is strong enough to support the weight of the unit and the floor is flat to prevent vibration and noise generatio
58. apply a screw lock agent for flare nuts to the screws of the shutoff valves and service ports Refer to the Handling Precautions for Valve Cover and Handling Precautions for Service Port in 6 5 Connecting the Refrigerant Piping for the handling of the valve covers and service ports 2 After the refrigerant replenishment is completed fill out the item total amount of refrigerant replenishment on the label of instruc tions on refrigerant replenishment of the outdoor unit with the actual amount of refrigerant replenishment Refer to the illustration of the label pasting position for instructions on refrigerant replenishment see the illustration on the above Precautions for refrigerant cylinder At the time of refrigerant filling check whether the siphon tube is pro vided Then locate the cylinder so that the refrigerant will be filled in the state of liquid see table below R410A is a mixed refrigerant the composition of which may change and the normal operation of the system may not be possible if the refrigerant is filled in the state of gas Cylinder provided with siphon tube EN Stand the cylinder upright and fill the refrigerant There is a siphon tube inside which makes it possible to replenish the refrigerant in the state of liquid without setting the cylinder upside down Other cylinders Stand the cylinder upside down and fill the refrigerant Pay attention so t
59. berschreitet die Zahl der installierten Ger te die Zahl des in der nachstehenden Abbildung gezeigten Musters sind die Ger te so zu installieren dass keine Kurzschl sse entstehen Was den Platz vor dem Ger t betrifft so ist der f r die lokalen K ltemittelleitungen notwendige Platz bei der Installation der Ger te zu ber cksichtigen Falls die Arbeitsbedingungen in der nachstehenden Abbildung nicht zutreffen wenden Sie sich an Ihren H ndler oder direkt an Daikin lt Bei Installation als einzelne Einheit lt Bei Installation in Reihe gt Muster 1 HINWEIS Muster 1 HINWEIS ee 1 ok a a ES o 33 1 ol S S59 oOo 858 ER O OOO a i l um 3 gt 10 210 EL 210 210 Sg eor g BE 207 77520 8 BE Vorderseite A ES Tt DRE 1 R ES NIE 123 L___ Vorderseite____ zB Muster 2 HINWEIS ae Muster 2 HINWEIS 8E ny Bs BS if rod i 59 prey c ee IUE i EE 10 128 SE y i a 50 50 Aug QE gt 38 ETA rs 8188 B 2 S8 2100 2100 8 88 Vorderseit Al SS 1 A t N gL Ba EL L Vorderseite ____ 185 3 i md Keine Begrenzung f r die Wandh he Muster 3 Muster 3 Deo sr i Te 8 Keine Begrenzung f r 8l O wee 10 X IO l 2200 2200 2400 2400 1 T gt gt Vorderseite Vorderseite HINWEIS F r Muster 1 und 2 Wandh he auf der Vorderseite nich
60. chluss des Zusatzger t dessen Installationsanleitung zur Hand Au enger teseite Leitungsgr e mm Leitung zwischen Au enger t und erster Verzweigung A a Fl ssigkeitsrohr Gasrohre 50 m oder weniger 50 130m 50 m oder weniger 50 130m 9 5 x 0 8 O typ 612 7 x 0 8 O typ 025 4 x 1 0 1 2H typ 628 6 x 1 2 1 2H typ Leitung zwischen Verzweigungsbereichen B b C c W hlen Sie aus nachstehender Tabelle die Leitungen entsprechend der Gesamtkapazit t der nachgeschalteten Innenger te Gesamtkapazit t der Innenger te nach der Verzweigung Gr e der Gasleitung Gr e Fl ssigkeitsrohr 18 5 kW und mehr 25 4 x 1 0 1 2H typ Weniger als 6 0 kW 612 7 x 0 8 O typ 66 4 x 0 8 O typ 6 0 kW oder mehr und weniger als 9 9kW 15 9 x 1 0 1 2H typ 89 5 x 0 8 O typ 9 9 kW oder mehr und weniger als 14 5 kW 019 1 x 1 0 1 2H typ i 22 2 x 1 0 1 2Ht 14 5 kW oder mehr und weniger als 18 5 kW 622 2 x 1 0 1 2H typ 612 7 x 0 8 O typ Keine Gr e nach der Verzweigung darf die Gr e vorgelagerter Leitungen bersteigen Leitung zwischen Verzweigungsbereichen und jedem Ger t bersteigt die Gr e des Anschlussrohrs des Innenger ts die des in voranstehender Tabelle dargstellten Zweigrohrs vergr ern Sie die Gr e des Anschlussrohrs in der N he des Innenger ts bevor Sie es anschlie en Klimaanlage Au enger teseite
61. control box lid that the RUN switch is set to OFF If the RUN switch is set to ON the fan may rotate Usean insulated rod to operate the push buttons via the EL COMPO BOX s inspection door There is a risk of electric shock if you touch any live parts since this operation must be performed with the power on Check the LED indicators on the PCB A1P of the outdoor unit through the inspection hole on the right hand side of the control box lid after the outdoor unit is turned on see the illustration The compressor will not operate for approximately 10 minutes after the outdoor unit and air conditioning indoor unit are turned on H2P will be turned off when in a condition to be able to operate a system H3P continues blink state Inspection hole right hand side upper right hand side of control box Control box lid LED H1 8P zm Lift up this tab and open the cover 8 3 Inspection hole cover Inspection hole right hand side Inspection hole left hand side Control box l q RUN switch ET factory set OFF N REMOTE OFF ON SS f N B Inspection hole left hand side upper left hand side of control box N WARNING Use protective gear e g protective gloves and glasses at the time of
62. ction of the unit 4 Where flammable gas may leak where there is carbon fiber or ignitable dust suspensions in the air or where volatile flamma bles such as paint thinner or gasoline are handled Operating the unit in such conditions may result in fire 5 Vehicles ships or other places that generate vibration or cause the CONVENI PACK to move The CONVENI PACK may malfunction or cause oxygen defi ciency accidents as a result of refrigerant leakage 6 Places with excessive voltage fluctuations The CONVENI PACK may malfunction 7 Places where fallen leaves accumulate or weeds grow thick 8 Places that become small animals shelter Small animals coming in contact with electrical parts can cause malfunctions smoke or ignition The CONVENI PACK is not intended for use in a potentially explo sive atmosphere 1 2 Special Notice of Product CLASSIFICATION This CONVENI PACK comes under the term appliances not accessible to the general public Follow the showcase to be connected for the climate class EN60335 2 89 EMC CHARACTERISTICS This System is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures REFRIGERANT This System use R410A refrigerant MN CAUTION This unit is already filled with a certain amount of R410A Never open liquid and gas shutoff valve until the step Specified in 9 CHECK
63. d The piping is different in size The strength of the piping is insufficient The compressor of the CONVENI PACK previously used caused a malfunction An adverse influence of residual substances such as the oxi dation of refrigerant oil and the generation of scale is consid ered fthe indoor unit or outdoor unit is disconnected from the piping for a long time The intrusion of water and dust into the piping is considered The copper pipe is corroded The refrigerant of the CONVENI PACK previously used was other than R410A e g R404A R507 or R407C The contamination of the refrigerant with heterogeneity is con sidered e fthere are welded connections midway on the local piping make gas leakage checks on the welded connections Be sure to insulate the connection piping The liquid and gas pipe temperatures are as follows Liquid pipe arrival minimum temperature 20 C Air conditioning side 5 C Refrigeration side Gas pipe arrival minimum temperature 0 C Air conditioning side 20 C Refrigeration side In the case of thickness insufficiency add additional insulation material or renew the existing insulation material Renew the insulation material if the insulation material is degraded Keep the following points in mind for the reuse of existing heat exchangers Units with insufficient design pressure since this product is an R410A unit require a lower stage design pressure of 2 5 MPa 25 bars Units
64. densate may drip on downstairs or walkway depending on the floor condition take a measure such as the installation of cen tral drain pan kit sold separately 4 The refrigerant R410A itself is nontoxic nonflammable and is safe If the refrigerant should leak however its concentration may exceed the allowable limit depending on room size Due to this it could be necessary to take measures against leakage See Engineering Data for details 4 HANDLING THE UNIT 1 Decide on the transportation route 2 If a forklift is to be used pass the forklift arms through the large openings on the bottom of the unit UUU Y YIII 1 Opening large 2 Fork 3 Fixed screws of transportation clasp 4 Transportation clasp yellow If hanging the unit use a cloth sling to prevent damaging the unit Keeping the following points in mind hang the unit following the procedure shown in the following figure Use a sling sufficiently strong to hold the mass of the unit Use 2 belts of at least 8m long Place extra cloth in the locations where the casing comes in contact with the sling to prevent damage Hoistthe unit making sure it is being lifted at its center of gravity 3 4 5 1 Belt sling 2 Patch cloth 3 Belt sling 4 Patch cloth 5 Opening 3 After installation remove the transportation clasp yellow attached to the large openings Note Apply a filler cloth on a fork to
65. e brazing should be set to 0 02 MPa about 0 2kg cm Enough to feel a slight breeze on your cheek Note Do not use anti oxidants when brazing the pipe joints Residue can clog pipes and break equipment 6 4 Drier Installation N CAUTION This product requires that a drier be installed on liquid piping on site Operating the unit without a drier installed may result in equipment failure Select a drier from the following chart Model Required dryer core recommended type 160g 100 molecular sieve equivalent ERYEQTONY DML164 DML164S Danfoss made Connect the drier to liquid pipe on the refrigeration side Install the drier in a horizontal orientation wherever possible Install the drier as close to the outdoor unit as possible Remove the drier cap immediately before brazing to prevent absorption of airborne moisture Follow instructions in the drier instruction manual concerning drier brazing Repair any burning of drier paint that occurs during drier brazing Contact the manufacturer for more information about paint for repair use Flow direction is specified for some type of the dryer Set the flow direction according to the operation manual of the dryer Liquid refrigerant flows from the outdoor unit to the indoor unit 6 5 Connecting the Refrigerant Piping N CAUTION e n addition to gas and liquid shutoff valves this unit has a mainte nance shutoff valve
66. e Arbeiten nur von qualifizierten Fachleuten unter Beachtung aller rtlich g ltigen Gesetze und Vorschriften und dieser Anleitung ausgef hrt wer den Eine unzureichende oder falsch ausgef hrte Betriebsstromver sorgung kann zu elektrischen Schl gen oder Br nden f hren Vergewissern Sie sich dass die gesamte Verkabelung sicher befestigt ist die vorgeschriebenen Kabeltypen verwendet werden und die Klemmenanschl sse oder Kabel keiner Belastung ausge setzt sind Falsche Anschl sse oder Befestigung der Kabel k nnen zu abnormaler W rmebildung oder einem Brand f hren Bei der Verkabelung der Stromversorgung und der Verbindung der bertragungskabel sind die Kabel so zu verlegen dass der Schaltkastendeckel sicher befestigt werden kann Falsche Anbringung des Schaltkastendeckels kann zu elektri schen Schl gen Brand oder berhitzen der Klemmen f hren Falls K ltemittelgas w hrend der Installation entweicht ist der Bereich sofort zu bel ften Giftiges Gas kann entstehen falls das K ltemittelgas mit Feuer in Ber hrung kommt berpr fen Sie die Anlage nach der Installation auf K ltemittel gaslecks Giftiges Gas kann erzeugt werden falls K ltemittelgas in den Raum entweicht und mit einer Feuerquelle wie z B einem Heiz k rper Ofen oder Herd in Ber hrung kommt Schalten Sie das Ger t unbedingt aus bevor Sie Elektroteile ber hren Vermeiden Sie direkte Ber hrung von K ltemittel das aus K lte mittelleitungen
67. e CONVENI PACK Do not earth the unit to a utility pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or fire A high surge current from lightning or other sources may cause damage to the CONVENI PACK Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks or fire N CAUTION While following the instructions in this installation manual install drain piping to ensure proper drainage and insulate piping to pre vent condensation Improper drain piping may result in indoor water leakage and property damage English Install the indoor and outdoor units power cord and connecting wires at least 1 meter away from televisions or radios to prevent picture interference and noise Depending on the incoming signal strength a distance of 1 meter may not be sufficient to eliminate noise e Do not install the CONVENI PACK in the following locations 1 Where there is a high concentration of mineral oil spray or vapor e g a kitchen Plastic parts will deteriorate parts may fall off and water leak age could result 2 Where corrosive gas such as sulphurous acid gas is produced Corroding of copper pipes or soldered parts may result in refrigerant leakage 3 Near machinery emitting electromagnetic radiation Electromagnetic radiation may disturb the operation of the control system and result in a malfun
68. e Einheit muss von Wartungspersonal des Herstellers oder ver 2 2 Beispiel der Systemkonfiguration essss 3 gleichbarem Fachpersonal durchgef hrt werden 2 3 Innenger t Einschr nkungen Gefrierung und Installieren Sie das CONVENI PACK gem f den Anweisungen in Getriermaschine etate tasa 3 dieser Installationsanleitung 3 AUSWAHL DES STANDORTS enneenenennnn 3 Eine unsachgem e Installation kann zu Wasserlecks elektri 4 HANDHABUNG DER EINHEIT eee 5 schen Schl gen oder Brand f hren 5 AUFSTELLEN DES GER TES eene 5 Treffen Sie bei der Installation des Ger ts in einem kleinen Raum 6 K LTEMITTELLEITUNGEN eee 6 Vorkehrungen so dass die Menge austretenden K hlmittels bei 6 1 Wahl des Rohrleitungsmaterials 7 auftretenden Lecks die zul ssigen Grenzwerte nicht berschrei 6 2 Schutz gegen Verunreinigung bei der Installation der tet Rohre ueeesssssnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnenennnnnnnnnn 8 Wenden Sie sich f r weitere Informationen an die Kaufstelle Eine 9 6 3 Leitungsanschl sse 6 4 Installation eines Trockners eeseeeeenee 6 5 Anschluss der K ltemittelleitungen BAUSEITIGE VERDRAHTUNG eene 7 1 Beispiel der Verkabelung des ganzen Systems 7 2 Verfahren f r eingehende Verkabelung 7 3 Verfahren f r
69. e outdoor unit when it is running If the CONVENI PACK is of brine Resin damage resistant or heavy brine dam washers age resistant type use nuts provided poy with resin washers to secure the prod uct to the foundation bolts see the illustration on the right hand side The rustproof effect of the nut will be lost if the coatings on the tightening portions of the nuts come off 6 REFRIGERANT PIPING To Piping Work Contractors Never open the shutoff valve until the steps specified in 7 FIELD WIRING and 8 3 Checking of Device and Installation Condi tions of piping Do not use flux at the time of brazing and connecting refrigerant pipes Use phosphorous copper brazing filler metal BCuP 2 which does not require flux Chlorine based flux causes piping corrosion Furthermore if fluoride is contained the flux will have adverse influences on the refrigerant piping line such as the dete rioration of refrigerating machine oil N CAUTION All field piping must be installed by a licensed refrigeration tech nician and must comply with relevant local and national regula tions Precautions for reuse of existing refrigerant piping heat exchangers Keep the following points in mind for the reuse of existing refrig erant piping heat exchangers A malfunction may result if there is deficiency Donotuse the existing piping in the following cases Perform new piping instea
70. e the amount of all refrigerant filling in this system 7 Liquid pipe size Total amount of refrigerant kg Refrigerant amount per 1m kg Pipe length m mm 6 4 0 02 a 9 5 0 06 b 912 7 0 12 c 15 9 0 19 d 1 Subtotal a b c d Amount of refrigerant Refer to table 1 and 2 Total Indoor unit capacity kW Refrigeration showcase A Frozen showcase B Blower coil C Air conditioning unit D 2 Subtotal A B C D 3 Constant amount of additional filling 3 5 4 Total of the amount of refrigerant replenishment 1 2 3 5 Amount of refrigerant replenishment at the time of test run 6 Amount of initial filling 7 Total additional charging amount 4 5 6 gj Indoor unit E Refrigeration L_ showcase Outdoor unit QB Blower coil m Frozen Booster unit showcase Table 1 Capacity and amount of refrigerant of the indoor unit Show case and Blower coil Total capacity of showcase or Amount of refrigerant kg blower coil Showcase Blew resil Note Refrigeration Frozen Less than 5kW 1 1 1 4 0 6 From 5kW to less than 10kW 2 3 3 2 1 2 From 10kW to less than 15kW 3 4
71. elaufs 6 Urspr ngliche F llmenge 11 5 7 Gesamte zus tzliche F llmenge 4 5 6 Innenger t K hlvitrine um Au enger t ede Gebl sespule Gasleitung Zusatzger t Tabelle 1 Kapazit t und K ltemittelmenge des Innenger ts Vitrine und Gebl sespule Gesamtkapazit t der Vitrine K ltemittelmenge kg oder der Gebl sespule Vitrine Verst rker Anmerkung Gefrierung Gefrier ger t Weniger als 5kW 1 1 1 4 0 6 Von 5 kW bis unter 10kW 2 3 3 2 1 2 Von 10 kW bis unter 15kW 3 4 5 2 1 7 Von 15 kW bis unter 20kW 4 6 2 3 20 kW oder mehr 5 9 3 0 Hinweis 1 Vitrinengeh use Kapazit tsbedingung Verdampfungstempera tur Gefrierung 10 C Gefroren 35 C 2 Gebl sespulengeh use Kapazit tsbedingung ist 10 C Ta Tabelle 2 Die K ltemittelmenge des Innenger ts f r die Klimaan lage HP Arten von 2 0 2 5 3 2 4 0 5 0 8 0 10 0 Innenger t Rundum ausblasendes Kas settenger t FXFQ Double Flow Kassettenger t FXCQ 0 5 0 7 08 1 1 05 0 9 0 9 0 9 1 0 Ceiling Built in FXSQ 0 3 0 6 0 5 1 0 1 0 Deckenmontierter Kanaltyp FXMQ 0 5 1 2 1 2 2 1 2 4 Deckenhangender Typ 08 FXHQ Deckenh ngende Kassette 09 14 FXUQ i Berechnen Sie f r jedes Ger t Abb
72. en Sie keines der Zubeh rteile weg bevor die Installation abge schlossen ist Rohr f r Rohr f r Name al ld Gasseite 1 Gasseite 2 Menge 11 Stck 1 Stck 1 Stck 0 Form Klein Rohr f r Rohr f r Name Rn NUES Fl ssigkeitsseite 1 Fl ssigkeitsseite 2 Menge 1 Stck 1 Stck Form Rohr f r Rohr f r Name Fl ssigkeitsseite Fl ssigkeitsseite Sonstiges 3 4 1 St ck zu jedem Menge 1 Stck 1 Stck Artikel Bedienungshand buch Installationsanlei tung Form bereinstimmung serkl rung PED Aufkleber ZUS T ZLICHE K LTEMIT TELF LLUNG 2 2 Beispiel der Systemkonfiguration Name Au enger t Zusatzger t Form Innenger t Name Gefrierung Klimaanlage m Gebl sespule Vitrine Form Innengerat Steuerta p Fernbedie Gefriermaschine fel o Name Entf Warntafel nung f r Kli Gebl se Vitrine Entfro maanlage spule sten Form O AL SS ER 1 2 3 tx IZ 4 1 Bedienungshandbuch 2 Installationsanleitung 3 Klemmen 4 Mitgelieferte Rohre Am Bodenrahmen installiert 2 3 Innenger t Einschr nkungen Gefrierung und Gefriermaschine Der Genehmigungsdruck f r das Innenger t liegt bei 2 5 MPa oder mehr
73. en Y Verbinder und f hren Sie die Verzweigung horizontal aus Dies verhindert ungleichm igen Fluss des K ltemittels Horizontale Y Verbinder Za Oberfl che AX A Pfeilansicht 30 oder weniger Gasrohre 7 Verwenden Sie zum Verzweigen des Gasrohrs einen T Verbinder und f hren Sie die Verzweigung so aus dass sich die Zweiglei tung Uber der Hauptleitung befindet siehe die nachstehende Abbildung Dadurch wird verhindert dass K ltemittel l im ruhenden Innenger t verbleibt Verwenden Sie einen T Verbinder f r die K ltemittelgas Zweigle itung und nehmen Sie den Anschluss auf der Oberseite der Hauptleitung vor T Verbinder Hauptleitung Zweigleitungen Die Leitung muss abw rts geneigt sein Hauptleitung Die Leitung muss abw rts geneigt sein Zweigleitungen Die Leitung muss abw rts geneigt sein Au enger teseite Vergewissern Sie sich dass der horizontale Abschnitt der Gasle itung zum Au enger t hin abw rts geneigt ist siehe die obige Abbildung Falls das Au enger t h her liegt bringen Sie Siphons am Gas rohr in 5 m Abst nden vom Au enger t an Dies gew hrleistet problemlose R ckf hrung von l in der aufw rts geneigten Rohr leitung BAUSEITIGE VERDRAHTUNG An Elektroinstallateure Installieren Sie unbedingt einen Fehlerstrom Schutzschalter Das Produkt enth lt Wechselrichterteile Um eine Funktionsst rung des Fehlerstrom Schut
74. end des Probelaufs nichts auf der Fernbedienung angezeigt pr fen Sie Folgendes Innenger t Klimaanlage 1 Ist die Stromzufuhr eingeschaltet 2 Ist die Verkabelung besch digt oder falsch angeschlossen zwis chen der Stromversorgung dem Innenger t und der Fernbedie nung 3 Ist die Sicherung auf der Platine geschmolzen Wird w hrend des Probelaufs ein St rungscode auf der Fernbe dienung angezeigt ergreifen Sie folgende Ma nahmen St rung Fehler bei der Installation Ma nahme scode E3 E4 Absperrventile geschlossen Offren Sie die Absperrven tile vollst ndig Entfernen Sie Hindernisse L4 Der Luftdurchlass ist blocki welchs den Luftdurchlaes ert y blockieren Ui Umkehrphase der Stromver Tauschen Sie zwei von drei sorgung Stromversorgungskabeln Pr fen Sie den Span U2 Spannungsabfall nungsabfall Pr fen Sie den Anschluss der bertragungsleitungen zwischen dem Au enger t und der Klimaanlage Pr fen Sie ob die Klimaan Falsche Verkabelung U4 UF der bertragungsleitungen zwischen den Ger ten Im Fall von Systemabwei UA chungen lage ordnungsgem ange schlossen ist E2 Kriechstrom Siehe 1 1 Stellen Sie den Betriebsschalter auf die Position OFF um die Stromversorgung zur ckzusetzen und stellen Sie dann den Schalter wieder auf die Position ON zur ck um das Ger t wieder zu starten Falls das Problem bestehen bleibt schla
75. equal to Zmax and W Sy greater than or equal to the minimum Sg value Zmax Q LRYEQ16AY1 0 24 minimum Sg value 1038KVA 1 European International Technical Standard setting the limits for voltage changes Voltage llucruations and flicker in public low voltage supply sys tems for equipment with rated current lt 75A 2 European International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low voltage systems with input current gt 16A and lt 75A per phase Operation output wiring connections Connect operation output wiring to the X2M terminal block and clamp as indicated by the following diagram X2M X2M wire specifications 0 75 1 25mm Max wiring length 130m Electric wire thickness 12 English N CAUTION Referto the 7 1 Example of Wiring Entire System by all means when connecting the operation output wiring A compressor failure may result if the operating output wiring is not connected Warning alarm wiring connections Connect warning alarm wiring to the X4M terminal block and clamp as indicated by the following diagram Mount insulation Fix the wiring with the sleeves provided clamp 1 X4M wire specifications Electric wire thickness 0 75 1 25mm Max wiring
76. er schrauben siehe die Abbildung auf der rechten Seite Der Rostschutzeffekt der Muttern geht verloren falls sich die Bes chichtung an den Anzugsteilen der Muttern l sen Deutsch 6 K LTEMITTELLEITUNGEN An Rohrleitungsinstallateure e ffnen Sie niemals das Absperrventil vor Erreichen der unter 7 BAUSEITIGE VERDRAHTUNG und 8 3 berpr fen des Ger ts und der Installationsbedingungen angegebenen Schritte f r die Leitungen e Verwenden Sie kein Flussmittel beim Hartl ten und Verbinden der K ltemittelleitungen Verwenden Sie zum Hartl ten eine Hartlotl egierung auf Kupfer Phosphor Basis BCuP 2 die kein Flussmit tel erfordert Flussmittel auf Chlorbasis verursacht Korrosion der Leitungen Falls dar ber hinaus Fluor enthalten ist hat das Flussmittel einen negativen Einfluss auf die K ltemittelleitung wie z B Verschlechterung des K ltemittel Maschinen ls ACHTUNG Alle Vor Ort Rohrleitungen m ssen von einem lizenzierten K ltetechniker installiert werden und den relevanten rtlichen und nationalen Vorschriften entsprechen VorsichtsmaBnahmen f r die Wiederverwendung von vorhan denen K ltemittelleitungen W rmetauschern Bei Wiederverwendung von K ltemittelleitungen W rmetaus chern die folgenden Punkte beachten Bei M ngeln kann es zu einer Funktionsst rung kommen Benutzen Sie die vorhandenen Rohrleitungen nicht in den fol genden F llen Verwenden S
77. gen Sie im Wartungshand buch nach Lassen Sie nach dem Austausch des Stromversorgungskabels und der bertragungsleitung die Stromversorgung des Innenger ts Klimaanlage K hlvitrine K hlger tek hler sowie 18 Deutsch die integrierte W rmekontrolltafel eingeschaltet schalten Sie den Betriebsschalter der Au enger te aus und dr cken Sie unter allen Umst nden die Drucktaste BS5 auf der Platine A1P im Schaltkasten rechts des Au enger ts f r mindestens 10 Sekunden ffnen Sie die Inspektionst r rechts im oberen rechten Teil des Schaltkastens und bet tigen Sie die Drucktaste BS5 mit Hilfe einer isolierten Stange Siehe Abbildung rechts O Inspektionst r rechts Oberer rechter Bereich des elektrischen Schaltkastens Weitere St rungscodes finden Sie im Wartungshandbuch ACHTUNG Unterbrechen Sie die Stromversorgung nicht f r 1 Minute nach dem Umschalten des Betriebsschalters auf ON Die Kriechstromerfassung wird f r mehrere Sekunden durch gef hrt nachdem der Betriebsschalter auf ON gestellt wurde und jeder Kompressor angelaufen ist so dass die Unterbrechung der Stromversorgung w hrend dieser Zeitspanne zu einer falschen Erfassung f hrt NM F r H ndler Pr fen Sie nach dem Abschluss des Probelaufs dass die Rohr leitungsabdeckung und die Frontplatte montiert sind e Erkl ren Sie dem Kunden bei der Auslieferung des Ger ts anhand der Bedienungsanleit
78. geration unit cooler 3 Turn on the operation switch from the inspection door of the out door unit The outdoor fan rotates in about 10 minutes after the operation switch is turned on and the compressor starts 4 Push the ON OFF button on the remote controller of the outdoor unit air conditioner to operate the unit 5 Check the sealing condition through the sight glass of the outdoor unit In case of shortage of refrigerant check if the refrigerant is charged to the specified level 16 English 6 Check the following on each unit Cold air should be blowing and the temper ature should decrease to the preset level The electronic expansion valve should be controlled on an appropriate superheated degree Refrigeration showcase The unit should start defrosting operation by the time set on the timer Cold air should be blowing and the temper ature should decrease to the preset level The electronic expansion valve should be controlled on an appropriate superheated degree Refrigeration unit cooler The unit should start defrosting operation by the time set on the timer Air conditioner Cold air or hot air should be blowing 7 Be sure to turn off the operation switch before turning off the power Error diagnosis Check the following if nothing is displayed on the remote controller lt 1 2 3 during the test run Indoor unit air conditioner gt
79. ges and areas around the edges using the repair paint 8 3 Checking of Device and Installation Condi tions Be sure to check the followings For those doing electrical work See 7 2 Procedure for Incoming Wiring 1 Make sure there is no faulty power wiring or loosing of a nut See 7 3 Procedure for Power Supply Wiring 2 Has the insulation of the main power circuit deteriorated Measure the insulation and check the insulation is above regular value in accordance with relevant local and national regulations For those doing pipe work 1 Make sure piping size is correct See 6 1 Selection of Piping Material 2 Make sure insulation work is done See 8 2 Thermal Insulation Work 3 Make sure there is no faulty refrigerant piping See 6 REFRIGERANT PIPING 9 CHECKS AFTER WORK COMPLETION Make sure the following works are complete in accordance with the installation manual m Piping work Wiring work Air tight test Vacuum drying Installation work for indoor unit Installation work for booster unit In case of the booster unit connection 10 REFRIGERANT REPLENISHMENT N For refrigerant filling contractor Use R410A for refrigerant replenishment The R410A refrigerant cylinder is painted with a pink belt N Warning A Electric Shock Warning Securely close the control box lid before turning power on Before turning power on check through the inspection hole on the left hand side of the
80. hat the cylinder will not topple down Check through sight glass e e Full of liquid A little foam Foam always flows comes out U X Refrigerant insufficiency O Sealing state N CAUTION Fully open the shutoff valves on the liquid and gas sides after the refrigerant replenishment is finished The compressor will malfunction if the system is operated with the shutoff valves closed Apply a screw lock agent to the screws of the valve cover mounting parts and service ports Otherwise dew condensation water will intrude and freeze inside and cause cap deformation or damage which may result in refrig erant gas leakage or compressor malfunctions 11 TEST RUN N For test run operators Do not operate the outdoor unit alone on a trial basis When you connect a booster unit refer to the installation manual attached to the booster unit before a test run Test run procedure Use the following procedure to perform a test run after installation work is complete for the entire system 1 Fully open the shutoff valves on the gas and liquid side of the out door unit 2 Check that the electric accessory box lids of the outdoor unit the indoor unit air conditioner refrigeration showcase refrigeration unit cooler and the piping cover of the outdoor unit are closed Then turn on the outdoor and indoor units air conditioner refrig eration showcase refri
81. hlossen ist schlagen Sie im Wartungshandbuch die Anweisungen in Bezug auf die zus tzliche K ltemittelbef llung nach Das K ltemittel muss f r dieses Produkt notiert werden Berech nen Sie die K ltemittel Nachf llmenge anhand des Aufklebers f r die Berechnung der K ltemittel Nachf llmenge Die Verfahren zur Berechnung der K ltemittelbef llungsmengen werden auf Seite 18 beschrieben Verwenden Sie das folgende Verfahren f r die K ltemittel Nach f llung Siehe 8 1 Luftdichtheitspr fung Vakuumtrocknung f r den Anschluss der K ltemittelflasche 1 Schalten Sie Innenger t und Steuertafel ein Schalten Sie nicht das Au enger t ein 2 F llen Sie K ltemittel ber den Wartungsanschluss des Absper rventils auf der Fl ssigkeitsseite nach 3 Falls die berechnete K ltemittelmenge nicht eingef llt werden kann f hren Sie die folgenden Schritte aus um das System zu bet tigen und die K ltemittel Nachf llung fortzusetzen a ffnen Sie das Gasabsperrventil vollst ndig und stellen Sie die ffnung des Fl ssigkeitsabsperrventils 1 ein b Warnung Stromschlagwarnung Schalten Sie das Au enger t ein c Warnung Stromschlagwarnung Schalten Sie den Betriebsschalter RUN des Au enger ts ein und f llen Sie K ltemittel nach w hrend das Au enger t in Betrieb ist d Schalten Sie den Betriebsschalter RUN des Au enger ts aus nachdem die vorgeschriebene K ltemittelmenge nach
82. ie statt dessen neue Rohrleitungen Die Gr e der Rohrleitungen ist unterschiedlich Die Festigkeit der Rohrleitungen ist unzureichend Der Kompressor des vorher verwendeten CONVENI PACK hat eine Funktionsst rung verursacht Ein negativer Einfluss von Restsubstanzen wie z B Oxidation von K ltemittel l und Kesselsteinbildung muss ber cksichtigt werden Wenn das Innenger t oder Au enger t lange Zeit von den Rohrleitungen getrennt war Das Eindringen von Wasser und Staub in die Rohrleitungen muss ber cksichtigt werden Die Kupferleitung ist korrodiert Es wurde ein anderes K ltemittel als R410A z B R404A R507 oder R407C f r das vorherige CONVENI PACK verwen det Verunreinigung des K ltemittels mit Ungleichartigkeit muss ber cksichtigt werden Falls Schwei verbindungen in der Mitte der rtlichen Rohrleitun gen vorhanden sind m ssen Gasleckpr fungen an den Schwei verbindungen durchgef hrt werden Die Verbindungsrohre m ssen isoliert werden Die Temperaturen der Fl ssigkeits und Gasleitungen sind wie folgt Minimale Ankunftstemperatur der Fl ssigkeitsleitung 20 C Klimaanlagen Seite 5 C K hlseite Minimale Ankunftstemperatur der Gasleitung 0 C Klimaanlagen Seite 20 C K hlseite Im Falle von unzureichender Dicke ist zus tzliches Isoliermaterial hinzuzuf gen oder das vorhandene Isoliermaterial zu erneuern Erneuern Sie das Isoliermaterial falls es sich ver
83. igt Falls der Druck steigt befindet sich Restwasser im System oder das System hat ein Leck Stickstoffgas 1 Kontaktieren Sie den Hersteller im Voraus um weitere Informa tionen ber den Genehmigungsdruck des Innenger ts vor Ort zu beschaffen zu erhalten 2 Die Lage des Wartungsanschlusses ist auf dem Anweisung saufkleber an der Frontplatte des Au enger ts unten angege ben Position des Anweisungsaufklebers Etikett Deutsch 15 Absperrventil Gasseiten Wartungsanschluss absperrventil Fl ssigkeitsseiten Druckminderventil absperrventil F llschlauch eu Au enger t El P Vio Zur Gefrierung E zer Innenger t E Vakuump me Zur Klimaanlage Verwendet zur Meter pump Innenger t Auff llung des Anmerkung Vorort Leitungen K ltemittels Anschlussverfahren f r Mehrzweck Manometer und Vakuumpumpe ACHTUNG F hren Sie einen Luftdichtheitstest und Vakuumtrocknung genau nach Vorschrift durch den Wartungsanschluss f r die fl ssigkeits und gasseitigen Absperrventile durch Schlie en Sie F llschl uche jeweils mit Druckstange versehen an die Wartungsanschl sse an Bei m glicher Wassereindringung in die Rohrleitungen F hren Sie in den folgenden F llen zuerst die oben beschriebene Vakuumtrocknung f r 2 Stunden durch Das Produkt wird w hrend der Regenzeit installiert es besteht die Gefahr von Taukondensation in
84. ildung 1 M Voll e Einige Blasen Blasen kommen Fl ssigkeit flie en st ndig heraus o Dichtungszustand 0 K ltemittelmangel x 20 Deutsch
85. iquid piping is calculated from the liquid piping size and the piping length of the system Calculate the refrigerant additional charging quantity by rounding off to the number in 0 1kg Total each piping size amount of the refrigerant 1 The amount of the refrigerant for the indoor unit of the refrigera tion is calculated from the capacity of the connected showcase as below table 1 1 Total all the refrigeration showcase capacities Total all the freezer showcase capacities Total all the blower coil capacities Calculate the amount of the refrigeration by the total capacities and the table 1 below of each indoor unit The amount of the refrigerant for the each indoor unit of the Air conditioner calculated from the capacity of the connected indoor unit as below table 2 Total each indoor unit amount of the refrigerant 2 Total the amount of the refrigerant of table below 1 2 and 3 4 Check sealing conditions through the sight glass at the time of test run If the sight glass has not been sealed yet due to the shortage of refrigerant charge additional refrigerant by 0 5kg 2 3 4 Note 8 9 The upper limit quantity of refrigerant adjustment at the time of the test run assumes 0 1 times of the quantity of refrigerant which calcu lated from the capacity of connected indoor units 5 lt 2 x 0 1 Fill the amount of the refrigerant replenishment on this label 5 Calculat
86. ity of indoor units B b C c connected downstream Total capacity of indoor units after branching Gas pipe size Liquid pipe size Less than 6 0 kW 612 7 x 0 8 O type 6 4 x 0 8 O type 6 0 kW or over and less than 9 9 kW 415 9 x 1 0 1 2H type 69 5 x 0 8 O type 9 9 kW or over and less than 14 5 kW 419 1 x 1 0 1 2H type 14 5 kW or over and less than 18 5 kW 22 2 x 1 0 1 2H type 12 7 x 0 8 O type 18 5 kW or over 25 4 x 1 0 1 2H type O type No size after branching can exceed the size of any upstream piping Piping between branching areas and each unit If the size of the connection pipe of the indoor unit exceeds that of the branch pipe shown in the table above enlarge the size of the connection pipe near the indoor unit before connecting it Air condition Piping size mm Liquid pipe Gas pipe Piping between outdoor unit and first 50m or less 50 130m 50m or less 50 130mm branch A2 a2 Outdoor unit side 9 5 x 0 8 O type 912 7 x 0 8 O type 25 4 x 1 0 1 2H type 28 6 x 1 2 1 2H type Piping between branching areas Select the piping from the following table in accordance with the total capacity of indoor units B2 b2 connected downstream Total capacity of indoor units after branching Gas pipe size Liquid pipe size Less than 16 0 kW 415 9 x 1 0 1 2H type 16 0 kW or over and less than 22 4 kW 419 1 x 1 0 1 2H type 9 5 x 0 8 O type 22
87. itzendr hte nicht mit L tmittel berziehen Tellerscheibe Kabeldicke 0 75 1 25 mm Crimpklemmen Schraubengr e Anzugsmoment Nem M8 Stromversorgungs Klemmen block 5 5 7 3 M8 Erde M4 X2M 2 39 2 91 M3 5 X3M 0 79 0 97 Max Kabell nge 130m Anmerkung Die Anschlussger te m ssen isoliert werden Anschl sse der Fernbetriebsschalterkabel Wenn Sie einen Fernbetriebsschalter installieren klemmen Sie die Kabel so an wie in der nachstehenden Abbildung gezeigt Befestigen Sie mit Hilfe einer Klemme vor Ort zu beschaffen den Betriebs X3M E e 9 Fernsteuerschalter am j Kunststoffblock E NA 1 I N I X3M Kabelspezifikationen Kabeldicke 0 75 1 25 mm Max Kabell nge 130m 7 4 Verkabelungsverfahren f r das Ger teinnere Die Starkstrom und bertragungskabel gem der nachste henden Abbildung mit den mitgelieferten Klemmen 1 2 und 3 sichern und verlegen Den Erdleiter so verlegen dass er nicht mit den Zuleitungen des Kompressors in Ber hrung kommt Andere Ger te werden beein tr chtigt falls der Erdleiter mit den Zuleitungen des Kompressors in Ber hrung kommen Sicherstellen dass keine Kabel mit den Rohren in Ber hrung kommen schraffierte
88. l und halten Sie ausreichenden Abstand zu Stereoger ten Personal Computern usw ein Besonders an Orten mit schwachem Empfang ist darauf zu achten dass ein Abstand von mindestens 3 m f r die Innenger te Fernbedienungen vorhanden ist dass die Strom versorgungskabel und die bertragungskabel in Schutzrohren verlegt und die Schutzrohre geerdet werden 2 Bei Installation an Orten mit starkem Schneefall sind die fol genden Schneeschutzma nahmen zu treffen Sicherstellen dass der Sockel hoch genug ist damit die Ein lass ffnungen nicht durch Schnee blockiert werden Montieren Sie eine Schneeschutzhaube Sonderzubeh r Den hinteren Einlassgrill abnehmen um die Ansammlung von Schnee auf den Lamellen zu verh ten 3 Falls Kondensat je nach den Bodenverh ltnissen auf ein tieferes Stockwerk oder Gehweg tropft sind Ma nahmen wie die Installation eines zentralen Abflusswannensatzes getrennt erh ltlich zu treffen 4 Das K ltemittel R410A ist ungiftig unentflammbar und sicher Sollte das K ltemittel jedoch austreten kann seine Konzentra tion je nach Raumgr Be die zul ssigen Grenzwerte berschre iten Aus diesem Grund kann es notwendig sein Ma nahmen gegen Undichtigkeit zu treffen Siehe Konstruktionsdaten f r Details Deutsch 4 HANDHABUNG DER EINHEIT 1 Legen Sie die Transportroute fest 2 Wenn ein Gabelstapler verwendet werden soll sind dessen Gabeln in die gro en ffnungen auf der Unter
89. l Nachf llung beendet ist Es kommt zu einer Funktionsst rung des Kompressors falls das System bei geschlossenem Absperrventil betrieben wird Tragen Sie Gewindebindemittel auf die Gewinde der Ventilde kkel Befestigungsteile und die Wartungsanschl sse auf Anderenfalls kann eindringendes Taukondensationswasser im Inneren gefrieren und Verformung oder Besch digung der Kappe verursachen was zu einem Leck von K ltemittelgas oder Funk tionsst rungen des Kompressors f hren kann 11 PROBELAUF A F r Probelauftechniker Betreiben Sie das Au enger t nicht probeweise allein Lesen Sie beim Anschluss eines Zusatzger t vor Durchf hrung eines Probelaufs die Installationsanleitung des Zusatzger t Probelaufverfahren F hren Sie einen Probelauf nach dem folgenden Verfahren durch nachdem die Installationsarbeit f r das gesamte System abgeschlo ssen ist 1 ffnen Sie die Absperrventile auf der Gas und Fl ssigkeitsseite des Au enger ts vollst ndig 2 berpr fen Sie dass Schaltkastendeckel des Au enger ts des Innenger ts Klimaanlage K hlvitrine K hlger tek hler sowie die Rohrleitungsabdeckung des Au enger ts geschlossen sind Schalten Sie dann die Au en und Innenger te Klimaanlage K hlvitrine K hlger tek hler ein 7 Achten Sie darauf den Betriebsschalter auszuschalten bevor Sie die Energiezufuhr abschalten Fehlerdiagnose Wird w hr
90. l block for the transmission wiring for warning alarm operation output and remote operation switch Otherwise the entire system will be dam aged Transmission wiring should be secured as described in 7 3 Procedure for Power Supply Wiring Secure wiring with clamp such as insulation lock ties to avoid con tact with piping Shape the wires to prevent the structure such as the control box lid deforming And close the cover firmly Route high voltage wiring power supply wiring earth wires and warning alarm operation wiring through wiring openings located on the side or front of the unit knock holes or on the bottom frame knock holes Route low voltage wiring for remote operating switches through wiring openings knock holes located on the front of the unit or through wiring intakes Electric wiring label Rear side of control box lid Through hole cover Cut the shaded area High voltage wiring Conduit Note Open the knock holes with a hammer or the like After knocking out the holes we recommend you remove any burrs and paint them using the repair paint to prevent rusting English 11 When passing electrical wiring through the knock holes protect the wiring with a conduit or bushings making sure not to damage the wiring f small animals might enter the unit block off any gaps hatching parts with material field supply Knockout hole For low voltage wiring K
91. llen Sie die Flasche aufrecht und f llen Sie das K ltemittel ein Im Inneren befindet sich ein Saugheberrohr mit dessen Hilfe das K ltemittel in fl ssigem Zustand aufgef llt werden kann ohne die Flasche auf den Kopf zu stellen Es muss kalte Luft geblasen werden und die Temperatur muss auf den voreingestellten Wert sinken Das elektronische Expansionsventil muss auf eine geeignete berhitzungsgradzahl einge stellt werden Das Ger t muss zu der im Timer eingestellten Zeit mit dem Entfrosten beginnen K hlvitrine Andere Flaschen Stellen Sie die Flasche auf den Kopf und f llen Sie das K ltemittel ein Achten Sie darauf dass die Flasche nicht herunter f llt Es muss kalte Luft geblasen werden und die Temperatur muss auf den voreingestellten Wert sinken Das elektronische Expansionsventil muss auf eine geeignete berhitzungsgradzahl einge stellt werden Das Ger t muss zu der im Timer eingestellten Zeit mit dem Entfrosten beginnen K hlger tek hler Kalte oder warme Luft muss geblasen wer Klimaanlage den Den F llstand durch das Schauglas berpr fen e e Gr Be der Es flieBt ein wenig Es kommt immer Sichtglas Gasleitung Schaum Schaum heraus M Cala O Dichtungszustand 3 K ltemittel unzureichend ACHTUNG ffnen Sie die Absperrventile auf der Fl ssigkeits und Gas seite vollst ndig nachdem die K ltemitte
92. lt 5 Summieren Sie die K ltemittelmengen f r jedes Innenger t 2 6 Summieren Sie die K ltemittelmenge aus nachstehenden Tabel len 1 2 und 3 4 7 Pr fen Sie beim Probelauf durch das Sichtglas den Dichtheitszu stand Wurde das Sichtglas aufgrund der Knappheit an K ltemittel bis her nicht abgedichtet f llen Sie zus tzlich 0 5 kg K ltemittel ein Hinweis Der obere Grenzwert f r die Anpassung der K ltemittelmenge zum Zeitpunkt des Probelaufs betr gt das 0 1 fache der K ltemittel menge die aus der Kapazit t der angeschlossenen Innenger te berechnet wurde 5 lt 2 x 0 1 8 Tragen Sie die K ltemittelnachf llmenge auf diesem Aufkleber ein 5 9 Berechnen Sie die Menge der gesamten K ltemittelbef llung die ses Systems 7 Fl ssigkeits Kajtemittel Leitungs Gesamtmenge leitungs x f s z Menge pro 1 m l nge an K ltemittel di kg m kg mm 6 4 0 02 a 69 5 0 06 b 612 7 0 12 c 615 9 0 19 d 1 Zwischensumme a b c d Menge an Innenger t e ad Kaltemittel KW Siehe Tabelle 1 und 2 K hlvitrine A Gefriervitrine B Gebl sespule C Klimaanlage D 2 Zwischensumme A B C D 3 Konstante Menge an zus tzlicher Bef llung 3 9 4 Gesamtmenge der K ltemittel nachf llung OLAS lt 5 Menge der K ltemittelnachf llung zum Zeitpunkt des Prob
93. luss Fl ssigkeitsseiten Absperrventil 69 5 Gasseiten Absperrventil 25 4 Wartungsanschluss Ni ph Ventildeckel CIE dk a EN JX Sechskantloch Dichtungsteil Ne Welle Anzugsmoment Nem schlie t im Uhrzeigersinn Absperrven Ww tilgr Ben Schaft Ventilk rper Ventildeckel Vartung sanschluss Sechs 69 5 5 4 6 5 kantschl ssel 13 5 16 5 4mm 11 5 13 9 Sechs 25 4 27 0 33 0 kantschl ssel 22 5 27 5 8mm ffnungsmethode 1 Den Ventildeckel entfernen und den Schaft mit einem Sechs kantschl ssel entgegen dem Uhrzeigersinn drehen 2 Den Schaft bis zum Anschlag drehen 3 Den Ventildeckel sicher festziehen Das f r die Gr e geeignete Anzugsmoment ist aus der obigen Tabelle ersichtlich Schlie methode 1 Den Ventildeckel entfernen und den Schaft mit einem Sechs kantschl ssel im Uhrzeigersinn drehen 2 Die Welle anziehen bis sie mit dem Dichtungsteil des Ventils in Ber hrung kommt 3 Den Ventildeckel sicher festziehen Das f r die Gr e geeignete Anzugsmoment ist aus der obigen Tabelle ersichtlich Handhabungsvorkehrungen f r Ventildeckel Achten Sie darauf dass der Dichtungsteil nicht besch digt wird Bei der Anbringung des Ventildeckels ein Gewindebindemittel auf das Schraubengewinde auftragen Kein Gewindebindemittel f r B
94. luss der Elektroarbeiten dass keine losen Steckverbinder oder Klemmen von irgendwelchen Elektroteilen im Steuerkasten vorhanden sind ONON A 8 INSPEKTION UND ROHRISOLIERUNG F r Installateure von Rohrleitungen Elektroteilen und A Probelauftechniker ffnen Sie das Absperrventil keinesfalls bevor die Isolierung des Hauptstromkreises gemessen worden ist Der gemessene Isola tionswert verringert sich falls die Messung bei ge ffnetem Absperrventil durchgef hrt wird ffnen Sie das Absperrventil erst nachdem die berpr fung und Einf llung von K ltemittel abgeschlossen ist Es kommt zu einer Funktionsst rung des Kompressors falls das CONVENI PACK bei geschlossenem Absperrventil betrieben wird 8 1 Luftdichtheitspr fung Vakuumtrocknung K ltemittel ist im Ger t eingeschlossen Halten Sie bei einem Luftdichtheitstest oder einer Vak A uumtrocknung der lokalen Rohrleitungen unbedingt das Fl ssigkeits und Gasabsperrventil geschlossen F r Installateure von Rohrleitungen Nach Abschluss der Rohrleitungsarbeit ist die folgende berpr fung genau durchzuf hren Um zu gew hrleisten dass das CONVENI PACK dem Druck ein wandfrei standh lt und um das Eindringen von Fremdstoffen zu verh ten verwenden Sie unbedingt f r R410A dedizierte Werkzeuge Um zu gew hrleisten dass das CONVENI PACK dem Druck einwandfrei standh lt und um das Eindringen von Fremdstoffen Mehrzweck Wasser Schmutz und Staub
95. malen S Wert ist Zmax Q LRYEQ16AY1 0 24 minimaler S Wert 1038KVA 1 Europ ische Internationale Technische Norm zur Begrenzung von Spannungs nderungen Spannungsschwankungen und Flimmern in ffentlichen Nieder spannungs Versorgungssystemen f r Ger te mit einer Nennstromst rke von lt 75 A Europ ische Internationale Technische Norm zur Begrenzung von Oberschwingungsstr men die von Ger ten erzeugt werden welche an ffentliche Niederspannungssysteme angeschlossen sind und einen Eingangsstrom von gt 16 A und lt 75 A pro Phase aufweisen 2 Deutsch 13 Betriebsausgangskabel Schlie en Sie Warnungs Alarm und Betriebsausgangskabel an den Klemmenblock X2M an und sichern Sie die Kabel wie in der nachstehenden Abbildung dargestellt XM Klemme 1 X2M Kabelspezifikationen Kabeldicke 0 75 1 25 mm Max Kabell nge 130m ACHTUNG Beachten Sie unbedingt 7 1 Beispiel der Verkabelung des gan zen Systems beim Anschluss der Betriebsausgangskabel Es kann zu einem Kompressorausfall kommen falls die Betrieb sausgangskabel nicht angeschlossen werden Warnungs Alarmkabel e Schlie en Sie Warnungs und Alarmkabel an den Klemmenblock X4M an und sichern Sie die Kabel wie in der nachstehenden Abbildung dargestellt Befestigen Sie die Isolierhulle P Kabel mit der anbringen enthaltenen Klemme 1
96. menteile Klemme f r Stromkabel Klemme f r bertragungskabel und Erdklemme auszu ben Installieren Sie einen Schalter mit dem sie alle Pole der Strom versorgung schalten k nnen Deutsch 11 7 1 Beispiel der Verkabelung des ganzen Systems Anmerkung 1 Verwenden Sie einen spannungslosen Kontakt f r Mikrostrom f r den Fernsteuerschalter nicht mehr als 1 mA 12 V DC Anmerkung 2 Gesamtkapazit t f r Warnung Alarm 0 5 A oder weniger bei AC 220 bis 240 V Kapazit t f r Betriebsausgang 0 5 A oder weniger bei AC 220 bis 240 V TI Timer f r Gefrierung FIH Elektromagnetisches Schaltsch tz 51T Thermostat f r Innentemperatureinstellung T2 Timer f r Gefriermaschine Abtauheizung 52T Abtauabschlussthermostat
97. n The piping length between the outdoor unit and the indoor unit may not exceed the allowable piping length Refer to 6 REFRIGERANT PIPING Locations where the unit s suction vent and outlet vent do not gen erally face the wind Wind blowing directly into the suction or outlet vents will interfere with the unit s operation If necessary install some kind of obstruction to block the wind The space around the unit is adequate for servicing and the min imum space for air inlet and air outlet is available See the Installation Space Examples for the minimum space requirements Installation Space Examples The installation space requirement shown in the following figure is areference for cooling operation when the outdoor temperature is 32 C If the design outdoor temperature exceeds 32 C or the heat load exceeds maximum capacity in all the outdoor unit take an even large space on the intake shown in the following figure During installation install the units using the most appropriate of the patterns shown in the following figure for the location in ques tion taking into consideration human traffic and wind If the number of units installed is more than that shown in the pat tern in the following figure install the units so there are no short circuits As regards space in front of the unit consider the space needed for the local refrigerant piping when installing the units If the work conditions in the
98. n Sie einen Trockner von der folgenden Tabelle aus Erforderlicher Trocknerkern Modell empfohlener Typ 160g 100 Molekularsieb Entspre LRYEQ16AY1 chung DML164 DML164S von Danfoss Schlie en Sie den Entfeuchter an das Fl ssigkeitsrohr auf der Gefrierseite an Installieren Sie den Trockner nach M glichkeit in horizontaler Ausrichtung Installieren Sie den Trockner so nah wie m glich am Au enger t Entfernen Sie den Trocknerdeckel erst unmittelbar vor dem Hartl ten um Absorption von Feuchtigkeit in der Luft zu ver h ten Befolgen Sie die Anweisungen in der Betriebsanleitung des Trockners bez glich des Hartl tens Reparieren Sie etwaige Verbrennungen des Trocknerlacks die w hrend des Hartl tens auftreten Kontaktieren Sie den Her steller f r weitere Informationen zum Ausbesserungslack Bei manchen Trocknertypen ist die Str mungsrichtung angege ben Stellen Sie die Str mungsrichtung gem der Betriebsanleitung des Trockners ein Fl ssiges K ltemittel flie t vom Au enger t zum Innenger t 6 5 Anschluss der K ltemittelleitungen N ACHTUNG Zus tzlich zu den Gas und Fl ssigkeitsabsperrventilen besitzt dieses Ger t ein Wartungsabsperrventil siehe nachstehende Abbildung Bet tigen Sie nicht das Wartungsabsperrventil Die Werkseinstellung f r das Wartungsabsperrventil ist offen Lassen Sie dieses Ventil w hrend des Betriebs immer in der offe
99. n completion of inspection and refrigerant charging open the shutoff valve The compressor will malfunction if the CONVENI PACK is operated with the shutoff valve closed 8 1 Air Tight Test Vacuum Drying Refrigerant is enclosed in the unit A Be sure to keep both liquid and gas shutoff valves closed at the time of an airtight test or vacuum drying of the local piping For piping work contractor On completion of piping work make the following inspection pre cisely To ensure that the CONVENI PACK withstand pressure properly and prevent the penetration of foreign substances be sure to use R410A dedicated tools To ensure that the CONVENI PACK with stand pressure properly and prevent the penetration of foreign substances water dirt and dust use an R410A dedicated gage manifold and charge hose R410A dedicated tools and R407C dedicated tools are different in screw specification Gauge manifold Charge hose Pay the utmost attention so that the pump oil will not flow backward into the system Vacuum pump while the pump is not in operation Use a vacuum pump that can vacuum down to 100 7kPa 5 Torr or 755mmHg Gas for airtight Nitrogen gas test use Air tight Pressurize the high pressure section of the system liquid piping to 3 8 MPa 38 bar and the low pressure section of the system gas piping to the design pressure 1 of the indoor unit field supply from the service po
100. n on optional accessory 2 1 Standard Supplied Accessories The following accessories are included The storage location of the accessories is shown in the figure Note Do not throw away any of the accessories until installation is complete Gas side Gas side Name Clamp 1 Clamp 2 accessory accessory pipe 1 pipe 2 Quantity 11 pcs 1 pc 1 pc S Shape Ys O Small English Liquid side accessory Liquid side accessory Name h pipe 1 pipe 2 Quantity 1 pc 1 pc Shape Liquid side Liquid side Name accessory accessory Others pipe 3 pipe 4 Quantity 1 pc 1 pc 1 pc about each item Operation manual Installation manual Shape Declaration of con formity PED ADDITIONAL REF CHARGE label 2 2 Example of System Configuration Name Outdoor unit Booster unit Shape Indoor unit Name Refrigeration Air conditioner Blower coil Showcase Shape O Indoor unit Remote Canitrot Warnin controller Name Freezer panel 9 Def panel for air Blower coil Showcase Defrost conditioner Shape Pop Operation manual Installation manual Clamps Accessory pipes Installed on bottom frame 1 2 3 2 3 Indoor Unit Constraints Refrigeration
101. nd that all electrical work is carried out by qualified person nel according to local laws and regulations and this installation manual An insufficient power supply capacity or improper electrical con struction may lead to electric shocks or fire Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting transmission wir ing position the wires so that the control box lid can be securely fastened Improper positioning of the control box lid may result in electric shocks fire or the terminals overheating If refrigerant gas leaks during installation ventilate the area immediately Toxic gas may be produced if the refrigerant gas comes into con tact with fire After completing installation check for refrigerant gas leakage Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire such as a fan heater stove or cooker Be sure to switch off the unit before touching any electrical parts Do not directly touch refrigerant that has leaked from refrigerant pipes or other areas as there is a danger of frostbite Do not allow children to climb on the outside unit and avoid plac ing objects on the unit Injury may result if the unit becomes loose and falls Be sure to earth th
102. nen Stellung Der Betrieb des Ger ts in geschlossener Stel lung des Ventils kann einen Ausfall des Kompressors verursa chen LH Wartungsabsperrventil Wartungsabsperrventil Fl ssigkeitsseiten Absperrventil mit Wartungsanschluss ausgestattet O Ni BUTS Gasseiten Absperrventil mit Wartungsanschluss ausgestattet 1 Richtung zum Herausf hren der Rohre Die lokalen Ger teverbindungsleitungen k nnen entweder vorn oder seitlich angeschlossen werden Herausf hrung durch die Unterseite wie in der nachstehenden Abbildung gezeigt Bei Herausf hrung durch die Unterseite die Vorpr gungs ffnung im Bodenrahmen verwenden lg IL Y Ya UUJ linker Anschluss Vorsichtsma nahmen beim Ausschlagen der vorgepr gten ff nungen Die vorgepr gte ffnung im Sockelrahmen durch Ausbohren der 4 umliegenden Vertiefungen mit einem 6 mm Bohrer ffnen Vorpr gung Bohren Vertiefung 4 Pl tze Deutsch e Besch digung des Geh uses vermeiden Nach dem Ausschlagen der Vorpr gungen ist es empfehlenswert etwaige Grate zu entfernen und mit Ausbesserungslack zu lacki eren um Rostbildung vorzubeugen Beim Durchf hren von Kabeln durch die vorgepr gten ffnungen sind die Kabel mit einem Schutzrohr oder Buchsen zu sch tzen um Besch digung
103. nittstelle zi Anmerkung 1 ca I n ll EA Q AC220 240V at A IA Hinweis 7 2 Verfahren f r eingehende Verkabelung Ein Schutzrohr f r Stromversorgungskabel verwenden F hren Sie die Hochspannungskabel Stromversorgungskabel Achten Sie darauf dass die Schwachstromkabel z B f r die Erdleiter und Warnungs Alarm Betriebskabel durch die Fernbedienung zwischen den Ger ten usw und die Stark Kabel ffnungen an der Seite oder Front des Ger ts Vorpr gung stromkabel nicht zu dicht beieinander verlaufen sondern mindes s ffnungen bzw am Bodenrahmen Vorpr gungs ffnungen tens 50 mm Abstand haben F hren Sie die Niederspannungskabel f r Fernbetriebsschalter Zu gro e N he kann elektrische Interferenz Funktionsst rungen durch die Kabel ffnungen Vorpr gungs ffnungen an der und Besch digung verursachen Vorderseite des Ger ts bzw durch die Kabeleinl sse Schlie en Sie die Starkstromkabel an den Starkstrom Klemmen Kennzeichnun elektrische Verkabelung R ckseite des Steuerkastendeckels block an und sichern Sie diese gem der Beschreibung in 7 2 Verfahren f r eingehende Verkabelung Schlie en Sie die Stromversorgung nicht an den Klemmenblock f r die bertragungskabel f r Warnungs Alarm Betriebsaus gabe und den Fernbetriebsschalter an Anderenfalls wird das gesamte System besch digt Die bertragungskabel sind gem der Beschreibung in 7 3 Verfahren f r Stromversorgungs
104. nock hole Gas side accessory pipe 3 Brazing Brazing Gas side piping field supply Liquid side piping field supply AN CAUTION e Check that the on site piping does not come in contact with other piping the bottom frame or side plate of the product Precautions for Piping Perform piping branching with the following conditions kept in mind Liquid piping Atthe time of branching the liquid piping use a Y joint and branch it horizontally This will prevent an uneven flow of refrigerant Y joint Horizontal EN Surface e 30 or less AX A arrow view Gas piping Atthe time of branching gas piping use a T joint and branch it so that the branched piping will be located above the main piping see the illustration below This will prevent the stay of refrigerant oil in the indoor unit not in operation Use a T joint for the gas refrigerant branch and connect from the top of the main piping T joint Main piping Indoor unit side Branch piping Make the piping slant downward Main piping Make the piping slant downward Outdoor unit side SRE Branch piping Make the piping N slant downward Make sure that the horizontal portion of the gas piping slants downward to the outdoor unit see the illustration above If the outdoor unit is located above make a trap on the gas pipe at 5 m interv
105. nockout hole 5 For high voltage wiring Bur A 7 3 Procedure for Power Supply Wiring Procedure for Power Supply Wiring 1 Power supply 3 phase 380 415 Overcurrent circuit breaker earth leakage circuit breaker all pole disconnection switch Earth wire Power supply terminal block Mount insulation sleeves Fix the power supply wiring for phases L1 L2 L3 and N respec tively with the provided clamp 1 to the resin clamp 7 Fixthe earth wire to the power supply wire phase N with the pro vided clamp 1 8 Earth wire Perform wiring so that the earth wire will not come in contact with lead wires of the compressor Otherwise noise generated may have a bad influence on other equipment 9 Ground terminal 10 When two wires are connected to a single terminal connect them so that the rear sides of the crimp contacts face each other Also make sure the thinner wire is on top securing the two wires simultaneously to the resin hook using the accessory N oo hf WO clamp 1 Clamp 1 Terminal block Crip style terminal Wire narrow Wire thick a ire thic Wi H 7 Resin hook Power circuit safety device and cable requirements X1M X4M terminal block A power circuit see the following table must be provided for con nection of the
106. oder Entflammung verursachen Das CONVENI PACK ist nicht f r den Einsatz in einer potentiell explosiven Atmosph re vorgesehen Das CONVENI PACK muss unbedingt geerdet werden amp 1 2 Besonderer Hinweis zum Produkt KLASSIFIZIERUNG Dieses CONVENI PACK f llt unter die Kategorie Ger te die der ffentlichkeit nicht zug nglich sind Schlie en Sie die der Klimaklasse entsprechende Vitrine an EN60335 2 89 EMV EIGENSCHAFTEN Dieses System ist ein Produkt der Klasse A In einer Wohnumge bung kann dieses Produkt Funkst rungen verursachen so dass der Benutzer angehalten ist angemessene Gegenma nahmen zu ergreifen K LTEMITTEL Dieses System verwendet das K ltemittel R410A ACHTUNG Dieses Ger t ist bereits mit einer bestimmten Menge R410A gef llt ffnen Sie keinesfalls das Fl ssigkeits und Gasabsperrventil bis zu dem unter 9 KONTROLLEN NACH ABSCHLUSS DER ARBEIT angegebenen Schritt Das K ltemittel R410A erfordert strenge Vorsichtsma nahmen um das System sauber trocken und dicht zu halten Lesen Sie das Kapitel K LTEMITTELLEITUNGEN aufmerksam durch und halten Sie sich genau an diese Verfahren A Sauber und trocken Das Eindringen von Fremdstoffen einschlie lich Mineral len wie z B SUNISO I oder Feuchtigkeit muss verhindert werden B Dicht Achten Sie bei der Installation darauf das System dicht zu halten R410A enth lt kein Chlor zerst rt nicht die
107. olgenden Orten 1 Orte mit hoher Konzentration von Mineral lnebel oder Dampf z B in einer K che Kunststoffteile k nnen sich zersetzen was zu Herunterfallen von Teilen oder Wasserlecks f hren kann 2 Orte an denen korrosive Gase wie z B Schwefels uregas erzeugt werden Korrosion von Kupferleitungen oder gel teten Teilen kann zu K ltemittellecks f hren 3 Orte in der N he von Maschinen die elektromagnetische Strahlung abgeben Elektromagnetische Strahlung kann den Betrieb des Steuer systems st ren und eine Funktionsst rung des Ger tes verur sachen 4 Orte an denen brennbare Gase ausstr men k nnen an denen Kohlenstofffasern oder entz ndliche Staubpartikel in der Luft vorhanden sind oder an denen leichtfl chtige Z nd stoffe wie Lackverd nner oder Benzin gehandhabt werden Der Betrieb des Ger tes unter solchen Bedingungen kann zu einem Brand f hren 5 Fahrzeuge Schiffe oder andere Orte die Vibrationen erzeu gen oder eine Verlagerung des CONVENI PACK verursachen Es kann zu einer Funktionsst rung des CONVENI PACK oder zu Unf llen mit Sauerstoffmangel durch K ltemittellecks kom men 6 Orte mit berm igen Spannungsschwankungen Es kann zu einer Funktionsst rung des CONVENI PACK kom men 7 Orte an denen sich Laub ansammelt oder Unkraut wuchert 8 Orte die Kleintieren Unterschlupf gew hren Kleintiere die mit Elektroteilen in Ber hrung kommen k nnen Funktionsst rungen Rauch
108. on 1 0 mm Wird der Typ O f r Rohrleitungen mit einem minimalen Durchmesser von 19 1 mm verwendet ist eine minimale Dicke von 1 2 mm erforderlich F hren Sie in diesem Fall unbedingt Hartl ten jeder Verbindung durch F hren Sie die Verrohrung innerhalb des in der folgenden Tabelle angegebenen Bereichs durch L nge der K ltemittelleitung Max zul ssige E Einwegleitungsl nge Aquivalenzl nge a b c di lt 130 m d ist der jeweils l ngere Wert von d oder e a2 b2 e1 lt 130 m et ist der jeweils l ngere Wert von d2 oder e2 a g a2 e2 Gasrohre A G A2 E Fl ssigkeitsleitung H3 H hendifferenz Falls kein Anschluss an Zusatzger l Max L nge der Zweigleitung tats chliche L nge b c di 30 m di ist der jeweils l ngere Wert von d oder e b2 e1 30 m e1 ist der jeweils l ngere Wert von d2 oder e2 AuBenger t Klima anlage Max H hendifferenz Ger t nter Au enger t H1 H2 lt 35 m zwischen Innen und Au enger ten Ger t uber Au enger t H1 H2 lt 10 m H hendifferenz zwischen Ger tek hler und Vitrine H3 lt 5m H hendifferenz zwischen Klimaanlagen Innenger ten H4 lt 0 5m Anmerkung Bringen Sie in 5 m Abst nden vom Au enger t Saugheber an K ltemittelleitungsgr e Gefrierung Hinweis Nehmen Sie beim Ans
109. ontyyauiq ZZ MHOHONEH SLMHXOL O Wa Dre dH Z eBaysnjepnnu Sooy planpfallg 07 weqwewalds IASA Z BAVIA 6 unpnjun n aptejebijeg u py q uuou e Jejepuejs mepibese ejnjn oy Isewiuejny a106 ezuuuegeunje ununingz UIOpOAEU WISeU s apejns a nfearznod es az npe yodpaid ez nue uojueunyop 1 uAuayeunou ijuKur ogeje iue nouuou iuf nouaopejseu s apouz A NS pZ waguawnyop WEINNEULOL wapo un ueriepuejs walsoloyas ysige uueiunfipeJou efeyoze Isojsiqye noyer el pey ez snwApounu hsnu jebed nuefopneu ejf pey ef jes ns snjuauunyop sniuunou sn eque 4 snyepuejs snypoinu neiwaz eyuime zz Widonis ALAMEH OHOPLUAD leBEUOUEM 80 eh eWaouo ndu yiHeW biot WHEMLeWdOH WAdY mun widetfHe1o elMtleuo eH 168191981042 Z ejeypueun arawu yeAejseA asyejejnsey piau ny eSapyuauunxop ajasaljewiou ajs e A eB ay ip epuers e 1 siu ue sasnaejsen uo oz POAEU puseu z npejys A ofefjqeiodn es ep waloBod pod Inyeuuou jwWIGrup ur ipsepuejs jwifupalseu z jupepis 6 anseou ejunijorujsui no ejejuuojuoo UL 9jezijnn y es eojsaoe eo eijipuoo no e neunou a jueuunoop 9 ye nes e psepuejs ajoeojeuun oguan no ejeyruuojuoo ul Juns gy welynnsul u zseu z elpobz es euew zn az wenuniem pod uofuffoezieuuou wojueuinyop yoAuu wou uofob ndajseu BowAm blelujads xefjeuzseu Juuazs selloje Jeyoze ey yeu yo unjuawnyop ope ueui qa ba Bea yeu yo AueAgezs Iqqeje ze yeujojaj atu 91 6 yepi ese uiuuejapou ewy n npjo nq elazn yewjo epunbninjunios Ip
110. ort 3 When routing high voltage wiring power supply wiring earth wires and warning alarm operation output wiring from the left side Connecting local piping Power supply terminal block X1M X2M terminal block for operation output Earth terminal block When routing high voltage wiring power supply wiring earth wires and warning alarm operation output wiring from the right side 9 When routing high voltage wiring power supply wiring earth wires and warning alarm operation output wiring from the front 10 Remote operating switch terminal block X3M 11 When routing remote operating switch wiring through a wiring opening 12 Separate by at least 50 mm 13 Stay ONO A English 13 14 Perform wiring carefully so that the sound insulation of the com pressor will not come off 15 Support 16 Fixed to the rear side of the support with the provided clamp 2 17 Fixed to the rear side of the support with the provided clamp 2 MN CAUTION On completion of electrical work check that there are no disconnected connectors or terminals of any electrical parts in the control box 8 INSPECTION AND PIPE INSULATION For piping work contractor electrical work contractor IN and trial run workers Never open the shutoff valve until the insulation measurement of the main power supply circuit is finished The measured insulation value will become lower if the measurement is made with the shutoff valve opened O
111. ployuay sepueAue essip je jespnio 1s uewnyop epuewBsDuiuje espuenepue saja JB pyepuejs apuaba Japjoyiano QL 3 wevmifdiomt WMWTIEH OHOBLJOO HMHEBOEQUOUOM XM viaouo du WeLHOWANOL w anenLendoH vus dt vun WeLdetHeLo Wrimort euo 1018191981009 60 Seg n SUI sessou se LOI opiooe ep sopezipn wefas sejse enb epsep s onewou s ojueunoop sono no s euuou sjejumbas s e Woo epepiuuojuoo We ogise go lex euu eye usew fepe ersynuugee uemueuinyop us caljesejoap ejsesoe pJajal as 3129 e jeuofjipuoo Jae ap ajeje ede eo auapundse eudoid ad esej9ap GW gy efoejejyop ezsfemiu AZoAjop uofugy woJojez Ajeuuipy ejepoui ez osoujerzpeiodpo buzobj M eusejm eu efruepep Gd LL Szoypeuon jezoxjejfu e aaku ye opoui sezepueieqetuyp e fbou puajelby ueqgepn eesspjejo selia CH 9 Isoupo enelzi eao es afoy eu elepaun ei POU ns ep nosoujoAo po woyyseja owon pst pod aln pe a Em S salnyejza iuesejuoid ojo as zwu y aoezyewy japoLu az soupanodpo guid ans an efnsejuoid ES p jew UEpIaNIEINLIOISELIN jeureqoye uesyntiouij UWE eue ueejjnniseA ejreuo UEBWOUISYA CENOU AID EL eJejyap euuep Ae seJgieq uos jejepousBuueuofsipuoxyny ep e 10 Jensue Bipuajsjiny Ja saseepua CN Zp jeje pJop euuop AB SIp18q WOS euJejepouisDuueuogipuoyn Ne BuesuepnAny e deysuefie jeje pep CS LL 18J01p9A UONeJEINEP euuep los eujejjepouifeejueeuuip fe Iesueeua Jepun 10129 Gia OL 3Q0HS O IN3SV IHOMd 39 3S THNNY LSN383AO WO
112. prevent coating of the bottom frame from coming off and rust from occurring when bringing in the unit with anti corrosion treatment type using a forklift English 5 PLACING THE UNIT Make sure the unit is installed level on a sufficiently strong base to prevent vibration and noise The base should be bigger around than the width of the unit s legs 66 mm and should support the unit If protective rubber is to be attached attach it to the whole face of the base The height of the base should be at least 150mm from the floor Secure the unit to its base using foundation bolts Use four com mercially available M12 type foundation bolts nuts and washers The foundation bolts should be inserted 20 mm Eq o N Corner hole Independent Beam Beam foundation foundation foundation foundation horizontal vertical o Center of the product Center of the product Base form Foundation bolt point 1240 4 15 x 22 5 1102 x GY T g FA GZ 2 02 qe a Pets NO N oo ovo 5 857 o comr50 O 777 VIT A x 4 9 9 Z Unit mm Base width and base bolt positions Note When installing on a roof make sure the roof floor is strong enough and be sure to water proof all work Make sure the area around the machine drains properly by setting up drainage grooves around the foundation Drain water is sometimes discharged from th
113. rdelmutter auf den Dichtungsteil auftragen Ziehen Sie den Ventildeckel nach dem Bet tigen des Ventils sicher fest Siehe Funktionsweise des Absperrventils f r das Anzugsmoment des Ventils Schraubengewinde Gewindebindemittel auftragen Ventildeckel B Absperrventil Teil der Befestigung des Dichtungsteil Ventildeckels Kein Gewindebindemittel auftragen Deutsch Handhabungsvorkehrungen f r den Wartungsanschluss Verwenden Sie f r den Wartungsanschluss einen F llschlauch mit Druckstange Bei der Anbringung der Kappe ein Gewindebindemittel auf das Schraubengewinde auftragen Kein Gewindebindemittel f r B rdelmutter auf den Dichtungsteil auftragen e Ziehen Sie die Kappe nach der Arbeit sicher fest Siehe Funk tionsweise des Absperrventils f r das Anzugsmoment der Kappe Kappe Dichtungsteil Kein Gewindebindemittel Schraubengewinde auftragen Gewindebindemittel auftragen ACHTUNG Tragen Sie Gewindebindemittel auf die Ventildeckelhalterung und das Schraubengewinde des Wartungsanschlusses auf Anderenfalls kann Kondenswasser ins Innere eindringen und gefri eren Daher kann es durch Verformung oder Besch digung der Kappe zu Ausstr men von K ltemittelgas oder einer Funktions st rung des Kompressors kommen 3 AnschlieBen der K ltemittelleitungen an die Au enger te Bei Anschluss an der Vorderseite Entfernen Sie zum Anschluss die Abdeckung des Absper
114. refrigerant gas in the piping is all col lected Operation Method of Shutoff Valves Follow the instructions below when operating each shutoff valve MN CAUTION Do not open the shutoff valve until the steps specified in 8 3 Checking of Device and Installation Conditions is com pleted Do not leave the shutoff valve opened without turning the power on otherwise refrigerant may be condensed in the compressor and the insulation of the main power supply circuit may be degraded e Be sure to use an exclusive tool to handle the shutoff valve The shutoff valve is not of back sheet type Excessive force imposed may break the valve Usea charge hose when using the service port Make sure that there is no refrigerant gas leakage after the valve cover and cap are securely tightened Tightening torque Check with the following table the sizes of shutoff valves incorporated by each model and the tightening torque values of the respective shutoff valves Shutoff valve sizes Liquid side shutoff valve 9 5 Gas side shutoff valve 25 4 E N Service port Ve a Ide Valve cover WER Hexagon hole Sealing part Shaft IN Shutoff Tightening torque Nem closes clockwise valve sizes Shaft valve body Valve cover Service port 9 5 5 4 6 5 Hexagon 510 5 wrench 4mm T 11 5 13 9 625 4
115. rigerant charge of the product W 2the additional refrigerant amount charged in the field and W O O the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the service cover Contains fluorinated greenhouse gases covered LD by the Kyoto Protocol of the product see unit R410A kg 1 name plate N O k 2 additional refrigerant Ao 9 2 amount charged in the field O 3 total refrigerant charge y L OO I Ju 4 Contains fluorinated greenhouse gases covered 6 5 by the Kyoto Protocol 4 1 factory refrigerant charge 5 outdoor unit 6 refrigerant cylinder and manifold for charging DESIGN PRESSURE Since design pressure is 3 8MPa or 38bar for R407C units 3 3MPa or 33bar the wall thickness of pipes should be more carefully selected in accordance with the relevant local and national regula tions 1 3 Disposal Requirements Dismantling of the unit treatment of the refrigerant oil and eventual other parts should be done in accordance with the relevant local and national regulations 2 BEFORE INSTALLATION N CAUTION When installing the indoor unit refer to the installation manual provided for the indoor unit Optional accessories are required for the installation of the prod uct Refer to the informatio
116. rt 2 do not exceed the design pres sure The system is considered to have passed if there is no decrease in the pressure over a period of 24 hours If there is a decrease in the pressure check for and repair leaks Vacuum drying Connect a vacuum pump to the service ports of both the liquid and gas pipes for at least 2 hours and vacuum the unit down to 100 7 kPa or below Then leave the unit for at least 1 hour at a pressure of 100 7 kPa or below and check that the vacuum gage reading will not rise If the pressure rises there is residual water in the system or the system has leakage 1 Contact the manufacturer in advance for more information about the design pressure of the indoor unit field supply 2 Referto the instruction label on the front panel of the outdoor unit below for the position of the service port Position of instruction label Shoutoff valve Gas side service port shoutoff valve Liquid side Pressure reducing valve Charge MA shoutoff valve hose A Vave Outdoor unit E Oe 2 e ee cas st To Refrigeration 345 Lice indoor unit EE ecc To Air conditioning Vacuum pum indoor unit Used for refrigerant Meter d replenishment Note Field pipings Connection procedure for gauge manifold and vacuum pump N CAUTION Conduct an airtight test and vacuum drying precisely through the service ports of both liquid and gas shutoff valves
117. rventils 3 Absperrventil Gasseite K hlger t 4 Absperrventil Fl ssigkeitsseite K hlger t 2 Absperrventil Gasseite Klimaanlage 1 Absperrventil Fl ssigkeitsseite Klimaanlage L ten Zubeh rrohr f r Fl ssigkeitsseite 1 Rohr f r Gasseite 1 Zubeh rrohr f r Fl ssigkeitsseite 2 Rohr f r Gasseite 2 Bei Anschluss an der Seite Unterseite Die Vorpr gung am Bodenrahmen ausbrechen und die Rohrleitun gen unter dem Bodenrahmen verlegen 3 Absperrventil Gasseite K hlger t 4 Absperrventil Fl ssigkeitsseite K hlger t 2 Absperrventil Gasseite Klimaanlage 1 Absperrventil Flugsigretsseite Klimaanlage Zubeh rrohr f r Fl ssigkeitsseite 3 Rohr f r Gasseite 3 Zubeh rrohr f r Fl ssigkeitsseite 4 Rohr f r Gasseite 4 Vorpr gung Durchbohren Sie die Vorpr gung L ten L ten Leitungen Fl ssigkeitsseite vor Ort zu beschaffen ACHTUNG Pr fen Sie dass die Vor Ort Rohrleitungen nicht mit anderen Rohrleitungen dem Bodenrahmen oder der Seitenplatte des Produkts in Ber hrung kommen Leitungen Gasseite vor Ort zu beschaffei 3 Vorsichtsma nahmen f r Rohrleitungen Beachten Sie bei der Durchf hrung von Rohrverzweigungen die fol genden Bedingungen Fl ssigkeitsleitung Verwenden Sie zum Verzweigen des Fl ssigkeitsrohrs ein
118. schlechtert hat Bei Wiederverwendung von vorhandenen W rmetauschern die folgenden Punkte beachten Ger te mit unzureichendem Genehmigungsdruck erfordern einen Genehmigungsdruck einer niedrigeren Stufe von 2 5 MPa da dieses Produkt ein R410A Ger t ist 25 bar Ger te f r welche die Leitung zum W rmetauscher so verlegt worden ist dass das K ltemittel von unten nach oben flie t Ger te mit Kupferleitungen oder L fterkorrosion Ger te die mit Fremdstoffen wie z B Unrat oder Schmutz ver unreinigt sind Deutsch 6 1 Wahl des Rohrleitungsmaterials Vergewissern Sie sich dass die Innen und Au enseite der verwendeten Rohrleitungen sauber und frei von Fremdstoffen wie z B Schwefel Oxid Staub Sp ne l und Fett sowie Wasser sind Es ist w nschenswert dass die maximale ladh sion in den Rohrleitungen 30 mg pro 10 m betr gt e Verwenden Sie die folgende Art von K ltemittelleitung Material Nahtloses Kupferrohr mit Phosphor Desoxidation C1220T O f r einen maximalen AuBendurchmesser von 15 9 mm und C1220T 1 2H f r einen minimalen AuBendurchmesser von 19 1 mm Gr e und Wanddicke der K ltemittelleitung Ermitteln Sie die Gr e und Dicke anhand der folgenden Tabelle Dieses Produkt verwendet R410A Der Stehdruck des Typs O kann unzureichend sein wenn er f r Rohrleitungen mit einem min imalen Durchmesser von 19 1 mm verwendet wird Verwenden Sie daher den Typ 1 2 H mit einer minimalen Dicke v
119. seite der Einheit einzuf hren YIII IMP Y 1 ffnung gro 2 Gabel 3 Befestigungsschrauben der Transportklammer 4 Transportklammer gelb Falls das Ger t aufgeh ngt werden muss ist eine Stoffschlinge zu verwenden um Besch digung des Ger tes zu vermeiden Punkte nach dem in der nachstehenden Abbildung gezeigten Verfahren auf e Verwenden Sie eine Schlinge die stark genug ist um das Gewicht des Ger tes zu tragen Verwenden Sie 2 Gurte von mindestens 8 m L nge Sch tzen Sie die Stellen an denen das Geh use mit der Schlinge in Ber hrung kommt durch zus tzliche T cher um Besch digung zu vermeiden Achten Sie beim Hochziehen des Ger tes darauf dass es an seinem Schwerpunkt angehoben wird 1 Gurtschlinge 2 Abdecktuch 3 Gurtschlinge 4 Abdecktuch 5 ffnung 3 Entfernen Sie nach der Installation die an den gro en ffnungen angebrachten Transportklammern gelb Hinweis Ein F lltuch an einer Gabel anbringen um zu verh ten dass sich der Belag des unteren Rahmens abl st und Rost auftritt wenn das mit Rostschutzbehandlung versehene Ger t mit einem Gabelstapler geliefert wird 5 AUFSTELLEN DES GER TES berzeugen Sie sich davon dass das Ger t in der Waage auf einem ausreichend starken Sockel installiert wurde um Vibra tionen und Ger uschentwicklung zu vermeiden Die Basis sollte gr er als die Breite der F e der Einheit 66 mm sein und
120. shutoff valve on the liquid side 3 If the calculated amount of refrigerant cannot be filled take the following steps to operate the system and continue refrigerant replenishment a Open the gas shutoff valve all the way and adjust the opening of the liquid shutoff valve 1 b Warning Electric Shock Warning Turn on the outdoor unit c Warning Electric Shock Warning Turn on the RUN switch of the outdoor unit and replenish refrigerant while the outdoor unit is in operation d Turn off the RUN switch of the outdoor unit after the specified amount of refrigerant is replenished e Caution Fully open the shutoff valves on the gas and liquid sides promptly Otherwise a piping explosion may result from liquid sealing Control box Label of instructions on refrigerant replenishment OO OO Label pasting position 1 The cylinder s internal pressure will drop when there is little refrig erant remaining in the cylinder making it impossible to charge the unit even if the liquid shutoff valve opening is adjusted In this sit uation replace the cylinder with one that has more refrigerant remaining Additionally if the piping length is long replenishing while the liq uid shutoff valve is fully closed may lead to activation of the pro tection system causing the unit to stop operation 1 After the work is completed
121. t h her als 1500 mm Wandh he auf der Ansaugseite nicht h her als 500 mm Wandh he f r die Seiten unbegrenzt Falls die H he die obigen Werte berschreitet die auf der n chsten Seite in der Abbildung gezeigten MaBe h1 und h2 berechnen und h1 2 zu dem Wartungsplatz auf der Vorder seite und h2 2 zum dem Wartungsplatz auf der Ansaugseite hinzuz hlen zu Da is y qd A SI S X o FAR Q it 5 5 Oo 1 i e y LL o o x gt o Q Sg gt no B Y Y Wartungplatz Wartungplatz h1 A tats chliche H he 2 h1 B tats chliche H he 500 X 500 h1 2 oder mehr Y 300 h1 2 oder mehr Y 100 h1 2 oder mehr Die Werte in Klammern gelten f r Muster 2 N ACHTUNG Verzweigungsschalter berstrom Schutzschalter Bedienpaneel Erdschlussschalter Warhtafel 1 Verzweigungsschalter i Uberstrom Schutzschalte Erdschlussschalter T S n L x S E Y 24500 gt 15 d 21800 PET son o ele 7 Vitrine mm 1 Ein Inverter CONVENI PACK kann von Mittelwellenfunk erzeugte St rger usche verursachen berpr fen Sie den Installationsort des Haupt CONVENI PACK und der Elektroka be
122. the circumstances N WARNING Ask your dealer or qualified personnel to carry out installation Work Do not attempt to install the CONVENI PACK yourself Improper installation may result in water leakage electric shocks or fire Maintenance personnel of the manufacturer or equivalent skilled personnel should install this unit Install the CONVENI PACK in accordance with the instructions in this installation manual Improper installation may result in water leakage electric shocks or fire When installing the unit in a small room take measures against to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage Contact the place of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Be sure to use only the specified accessories and parts for instal lation work Failure to use the specified parts may result in the unit falling water leakage electric shocks or fire Install the CONVENI PACK on a foundation strong enough to withstand the weight of the unit A foundation of insufficient strength may result in the equipment falling and causing injury Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Failure to do so during installation work may result in the unit fall ing and causing accidents Make sure that a separate power supply circuit is provided for this unit a
123. uay ueueue EDGZ vajuasejyAn ojo alnyezza es auopy eu Ajopoui gugezyewy 0a az soupanodpoz nujseja eu alnsejyAn Gre pz Je ep Is seame weuny zn lejeuopipuoy este njapow oyyleyszn yere ex euloaljde nqipyique nujid Je AD z Jejyep IS euioyre ejf swauny teiepoui hsiejaud ouneuoripuoy 0 0 pex eiqjeys eq uoyese ones eXstsi ED ZZ uutiedeintatf ELL HOEHLO 99 010 BE WMfTeLe10HM EHKMLENNLDI OLn rafon h 1190Hd080 L0 8089 en edideuret Ge Z 1Jepnul ajauupeaseunp peanjnny ejje IuoorsjeJepjep engjosaey Je jasnjnjse ny jare ewo qejuu Gs OZ egeueu eAefzi as aJajey eu aesdeu y ysjewiy epoui os ep ellnefzi ofjsousonobpo osa z 63 6 apa uefaq nundnpjo ISIHIOTIB ANININNAN 39 AGOHZ 3INISYIHAA J39 3MBLOL8LOLO VE BUNVAVUMA 39 31VLIWHO 3NO2 3073l viv 1930 39 I9S0NGO9Z VIO Viv DI30 39 0 03 Menuer jo ug jueunjedeq joguo Aeng 1eBeue g HION Menzey 3P263176 1 2 njyurue euieid lt g gt oues po oualueloo ounzod lt y gt n ouazojz af oxe GL 9 eipeeyyuas ieAejse fug lt g gt prap See el v sipueuunyop pnjepigu uo neu oz 9 uioyeypyeo s npapis o IBIS s OUIQOPO Ul v A ouogojop a 103 G lt gt ujuagpeAso s npejnos lt B gt ougiglfz euNyzod e lt y gt A ouepenn oq ye y nsespoynu 2 ugeexyrueg V U SYEM U UO lt g gt eyo el y esseliyzise paniso uo eyo EL 9 IMEI no ajejuucjuoo ul lt B gt 3P Ayzod jeloaide
124. ug um das Gewicht der Einheit zu tragen und der Boden ist flach so da Vibrationen und L rm vermieden werden Die Leitungsl nge zwischen Au en und Inneneinheit darf die zul ssige Leitungsl nge nicht berschreiten Siehe 6 K LTEMITTELLEITUNGEN Orte an denen die Ansaug und Auslass ffnungen des Ger tes normalerweise keinem Wind ausgesetzt sind Wind der direkt in die Ansaug oder Auslass ffnungen weht beeintr chtigt den Betrieb des Ger tes Installieren Sie n tigenfalls einen Windschutz um den Wind abzuweisen Es muss ausreichend Platz f r die Wartung um das Ger t vorhanden sein und der minimale Platz f r den Lufteinlass und Luftauslass muss vorhanden sein Siehe die Installationsort Beispiele f r die minimalen Platzan forderungen Installationsort Beispiele Die in der nachstehenden Abbildung gezeigte Installationsplatz Anforderung dient als Referenz f r K hlbetrieb bei einer Au entemperatur von 32 C Falls die Au entemperatur 32 C berschreitet oder die W rme belastung die Maximalkapazit t in allen Au enger ten ber schreitet ist der in der nachstehenden Abbildung gezeigte Platz f r den Lufteinlass weiter zu vergr ern Die Ger te sind so zu installieren dass f r den jeweiligen Instal lationsort das am besten geeignete Muster unter denen in der nachstehenden Abbildung gezeigten verwendet wird wobei Per sonenverkehr und Wind zu ber cksichtigen sind
125. ung ausf hrlich die Handhabung der Anlage F r Vorsichtsma nahmen bei der Auslieferung nehmen Sie auch auf die mitgelieferte Installationsanleitung des jeweiligen Ger ts Bezug Deutsch Berechnungsmethode f r die zus tzliche K ltemittelf llmenge Mit diesem Produkt muss das K ltemittel vor Ort aufgef llt werden Berechnen Sie anhand folgender Punkte die K lte mittelnachf llung und notieren Sie die K ltemittelmenge in der nachstehenden Liste 1 Die Menge an K ltemittel f r die Fl ssigkeitsleitungen wird berechnet aus der Gr e der Fl ssigkeitsleitungen und der Lei tungsl nge des Systems Berechnen Sie die zus tzliche K lte mittelf llmenge durch Aufrunden der Zahl auf volle 0 1 kg 2 Summieren Sie f r jede Leitungsgr e die K ltemittelmenge 1 3 Die Menge an K ltemittel f r das Innenger t der Gefrierung berechnet sich aus der Kapazit t der angeschlossenen Vitrine wie nachstehend in Tabelle 1 dargestellt 1 Summieren Sie alle K hlvitrinen Kapazit ten 2 Summieren Sie alle Gefriervitrinen Kapazit ten 3 Summieren Sie alle Gebl sespulen Kapazit ten 4 Berechnen Sie die Menge der Gefrierung mit Hilfe der Gesamtkapazit ten und der nachstehenden Tabelle 1 jedes Innenger ts 4 Die Menge an K ltemittel f r jedes Innengerat der Klimaanlage berechnet sich aus der Kapazit t des angeschlossenen Innenge r ts wie nachstehend in Tabelle 2 dargestel
126. verkabelung Sichern Sie die Kabel mit Klemmen wie z B Isolations Kabel bindern um Kontakt mit den Rohrleitungen zu vermeiden Formen Sie die Kabel um Strukturen wie z B den Steuerkas tendeckel vor Verformung zu sch tzen Schlie en Sie den Deckel einwandfrei ffnungsabdeckung Schneiden Sie pee denschattierten Bereich zg Niederspannungsleitung 12 Deutsch Hinweis Die Vorpr gungs ffnungen mit einem Hammer oder dergleichen ffnen Nach dem Ausschlagen der Vorpr gungen ist es empfehlenswert etwaige Grate zu entfernen und mit Ausbesserungslack zu lacki eren um Rostbildung vorzubeugen Beim Durchf hren von Kabeln durch die vorgepr gten ffnungen sind die Kabel mit einem Schutzrohr oder Buchsen zu sch tzen um Besch digung zu vermeiden Falls die M glichkeit besteht dass Kleintiere in das Ger t eindrin gen sind etwaige L cken schraffierte Teile mit Dichtungsmate rial vor Ort zu beschaffen zu blockieren Vorpr gung F r Niederspannungsleitung Vorpr gung 5 F r Hochspannungsleitung Grat X 7 3 Verfahren f r Stromversorgungsverkabelung Verfahren f r Stromversorgungsverkabelung 1 Stromversorgung 3 Phasen Strom 380 415 berstrom Schutzschalter Fehlerstrom Schutzschalter Trennschalter f r
127. y box right of the outdoor unit for at least 10 seconds Open the inspection door right on the upper right portion of the electric accessory box and operate the push button switch BS5 using an insulating rod See the right figure O Inspection door right Upper right portion of the electric accessory box Refer to the Service Manual for other malfunction codes N CAUTION Do not disconnect the power supply for 1 minute after setting the operating switch to ON Electric leak detection is performed for several seconds after the operating switch is set to ON and each compressor starts oper ating so disconnecting the power supply during that time will result in a false detection A For dealers After the test run is finished check that the piping cover and front panel are mounted e Atthe time of delivery to the customer use the Operation Manual and fully explain the handling of the equipment For precautions at the time of delivery refer to the provided Instal lation Manual for each unit as well English 17 Method of calculating additional refrigerant charging quantity This product must fill the refrigerant in the field Calculate the amount of refrigerant replenishment according to the following points and note the amount of the refrigerant in a list shown below The amount of the refrigerant for the l
128. zschalters zu verh ten stellen Sie sicher dass er Oberschwingungen standh lt Benutzen Sie das CONVENI PACK nicht eher bis die Verlegung der K ltemittelleitungen abgeschlossen ist weil sonst eine Funk tionsst rung des Kompressors auftritt Entfernen Sie keine elektrischen Komponenten wie z B Ther mistoren oder Sensoren wenn Sie Stromversorgungskabel oder bertragungskabel anschlie en Es kann zu einer Funktions st rung des Kompressors kommen falls die Klimaanlage ohne solche elektrischen Komponenten betrieben wird N ACHTUNG S mtliche bauseitigen Verdrahtungen und Bauteile m ssen von einem zugelassenen Elektriker installiert werden und den entsprechenden rtlichen und staatlichen Vorschriften entspre chen Es mu eine eigene Netzleitung vorhanden sein Verwenden Sie nie eine Netzleitung zusammen mit anderen Ger ten Auf keinen Fall einen Phasenverschiebungskondensator install ieren Da dieses Ger t mit einem Wechselrichter ausgestattet ist wird durch den Einbau eines Phasenverschiebungskondensators nicht nur der Leistungsfaktor Verbesserungseffekt verschlechtert sondern es kann auch zu einer abnormalen Kondensatorerw r mung durch Hochfrequenzwellen kommen Die Verkabelung erst durchf hren nachdem jegliche Stromzufuhr unterbunden worden ist Kabel sind stets gem den relevanten rtlichen und nationalen Bestimmungen zu erden Diese Maschine enth lt einen Wechselrichter Einen Erdleiter anschlie en