Home
        CENTRISART® A-14
         Contents
1.                             Fig  1  Layout of the centrifuge    1 Lid  2 Display  3 User interface  see   chapter 6 4 1  User Interface             E       o  ae    4 6 5             Fig  2  Rear view of the centrifuge  4 Name plate  see  gt  chapter 2 1 2  Name plate      5 Mains power switch  6 Mains power input    Layout and Mode of Operation       2 1 2 Name Plate    2 2 Mode of Operation    2 2 1 Centrifugation  Principle    10    Layout and Mode of Operation                Fig  3  Example of a name plate    1 Type  2 Serial number  3 Max  speed  4 Max  kinetic energy  5 Max  density  6 Nominal voltage  7 Input fuse  8 Symbol for special disposal  see chapter 9  Disposal    9 CE mark in compliance with the directive 2006 42 EG  10 Part number  11 Year of manufacture  12 Power consumption    Centrifugation is a process for the separation of heterogeneous mixtures of  substances  suspensions  emulsions  or gas mixtures  into their components  The  mixture of substances  which rotates on a circular path  is subject to centripetal  acceleration that is several times greater than the gravitational acceleration     Centrifuges use the mass inertia inside the rotor chamber for separating the  substances  Due to their higher inertia  particles or media with a higher density travel  outwards  In doing so  they displace the components with a lower density  which in  turn travel towards the center     The centripetal acceleration of an object inside a centrifuge  as the effect of  
2.       Test report no   028 713000202 000    Date  2012 05 10       Page 1 of 1    T  V S  D AMERICA INC    10 Centennial Drive e Peabody MA 01960 USA    www TUVamerica com Tuv         52       NRTL Certificate          11  Index    Acceleration time  Accident prevention  Acid   Adapters   Aeration   Alkaline solutions  Ambient temperature  Angle rotor  Autoclaving    BGR 500    Capillaries  Centrifuges  Chemical reactions  Cleaning agents  Condensation  Connected load  Connection cable  Contamination  Continuous heat resistance  Continuous run  Corrosion   Cracks    Deceleration time  Decontamination agent  Density   Disinfectants  Disinfection   Display   Disposal   Disruptions   Drive    Electrical connection  Electronics   Emissions   Error   Error message    Flammable substances  Fuse    General safety instructions  Glass breakage   Glass particles  Gravitational field    28  7 43  16  33  44  19  33  39  20  43  35    13    44  7 10   34   33   19   39   7   15  33   35   24   16  33  35  16  34    28  34  40  35  35  26  38  16  16  23    39  24  15  24  30    15  19    13  14   35   35   11  22  26  39   40  43  44    Hazard warnings  Hazardous materials  Humidity    Imbalance   Installation site  Intended use  Interference suppression  IP code    Lid lock device    Mains power switch  Maintenance  Malfunction   Material abrasion   Max  speed of vessels  Microhaematocrit rotor  Motor bearings   Motor shaft    Noise level  Nominal voltage  Normal run mode    Occupationa
3.     1 1  Kaliumpermanganat KMnO  100 1 4 1 1 1   1   1 1  Kupfersulfat CuSO  x 5H 0 10 1 1 1 1 1 1 1 1 1 4  Magnesiumchlorid MgCl  10 1 1 1 1 1 1 1 1 1 1  Methanol CH 0 100 1 2 4 1 1 3 1 3 1 1  Methylethylketon  MEK  GH 100 1 1 4 1 1 4 4 4 1 1  Milchs  ure CHA  3 1 3 1 2 1 1 2   1 1  Mineral  l     100 1 1 1 1 1 1 1   1 1  Natriumbisulfit NaHSO  10 1 1 2 4 1       1 1  Natriumcarbonat Na CO  10 1 1 1 1 1       1 3  Natriumchlorid NaCl 30 1 1 1 1 1 1 1 1 1 3  Natriumhydroxid NaOH 30 1 1 4 1 1 1 1 1 1 4  Natriumhydroxid NaOH 50 1 1 4 1 1 1 1   1 4  Natriumsulfat Na SO  10 1 1 1 1 1 1 1 1 1 1  Nitrobenzol C H NO  100 3 4 4 3 2 4 4 4 1 1    104   bersicht       Bestandigkeiten bei 20   C      keine Angabe                                                                                                                   1 sehr gut bestandi ke E c  2 gut best  ndig 8      gt   3 bedingt best  ndig   o g g Cc  4 unbest  ndig E E   E    5       S    M o o  gt  E 9 9     E  amp E 2   5  f 5  E P P  z   5 E E D E   z ss 5 22 2 2 2 2 E E   S r  o 2 2 2    2 2 2 2  amp   Medium Formel  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL    ls  ure CisH3403 100 1 1 1 2 1 1   1 1  Oxals  ure C H50  x 2H 0 100 1 3 1 4 1 1 1 1 1 1  Ozon 0  100 3 4 1 4 3 1 1   1 2  Petroleum     100 1 1 3 1 1 1 1 3 1 1  Phenol C H O 10 1 4 4 4 1 4 1 3 1 1  Phenol C H O 100 2 4 4 4 1 3 4 3 1 1  Phosphorpentachlorid   PCI  100   4 4 4 1   4 4 1 1  Phosphors  ure H PO  20 1 4 2 4 1       1 4  Pyridin CHN 100 1 1 4 1 3 4 4 4
4.     Sollwert Drehzahl wird Netz aus   ein  Falls der Fehler sich wiederholt  Ser   unver  ndert angezeigt vice verst  ndigen        Deckel erneut   ffnen und schlie  en   Falls sich der Fehler trotz verriegeltem Deckel   schloss wiederholt  Service verst  ndigen           Zentrifuge zeigt nach dem Netz aus   ein  Falls sich der Fehler wiederholt   erneuten Einschalten einen Fehler Service verst  ndigen   aus der Gruppe 1 bis 18 an   siehe  gt  Kapitel 10 4 1 Fehlertabelle     Fehler 19 Durch Betatigen der Deckeltaste quittieren     Bei z  B  Stromausfall besteht die M  glichkeit  den Zentrifugendeckel manuell mit  einem Steckschl  ssel  im Lieferumfang enthalten  zu   ffnen  Die Offnung befindet  sich am Bodenblech im linken vorderen Viertel        A    VORSICHT     Der Deckel darf nur bei stehendem Rotor entriegelt und ge  ffnet werden   Wird der Deckel   ber die Notentriegelung w  hrend des Laufes ge  ffnet   schaltet die Zentrifuge sofort ab und l  uft frei aus            Schalten Sie den Netzschalter aus und ziehen Sie das Netzkabel aus der Steckdose      Zentrifuge ein St  ck   ber die Tischkante ziehen  ggf  aufbocken  z B  auf zwei  Holzkl  tzen   dabei darauf achten  dass sich der Schwerpunkt des Ger  tes noch    ber der Tischplatte befindet      Den Notentriegelungsschl  ssel in die Bohrung  siehe Abbildung  Pos  1  einf  hren  und auf die Achse des Deckelschlossmotors aufstecken          Die Achse mit Hilfe des Schl  ssels vorsichtig im Uhrzeigersinn drehen   bis de
5.     a2 E 5 o       S  S SS u e z  gt  S   E E E  5 S   E   z f    E E     E  z s gt  5 22 E 2 2 2 E E  S Z   2g 2 2 2 2 2 2 EF  amp   Medium Formula  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL  Acetaldehyde C H 0 40 3 2 4 2 3 4 4   1 1  Acetamide C H NO saturated 1 1 4 1 1 4 4   1 1  Acetic acid C H 0  10 1 4 1 1 1 1 1 1 1 1  Acetic acid C H 0  90 1 4 4 4 1 3 1 4 1 1  Acetic acid methyl ester C4H50  100 1 1 4 2 1   4 4 1 1  Acetone C H 0 100 1 1 4 1 1 4 4   1 1  Acrylonitrile C H4N 100 1 1 4 3 3 4 4 4 1 1  Allyl alcohol CHA 96 1 3 3 2 2 2 2 4 1 1  Aluminum chloride AICI  saturated 1 3 2 4 1   1   1 4  Aluminum sulfate Al  SO    10 1 1 1 3 1 1 1 1 1 1  Ammonium chloride  NH  CI aqueous 1 1 1 2 1 1 1 1 1 3  Ammonium hydroxide NH    H O 30 1 3 4 1 1 2 1   1 1  Anilin C H N 100 1 3 4 1 2 4 4 4 1 1  Antimony trichloride SbCl  90 1 4 1 4 1   1   1 4  Benzaldehyde C H 0 100 1 3 4 1 1 3 4 4 1 1  Benzene C H  100 3 2 4 1 3 4 4   1 1  Benzine CH    Col 100 2 1 3 1 3 3 2   1 1  Benzyl alcohol C H40 100 3 4 4 1 4 4 2   1 1  Boracic acid H4BO  aqueous 1 3 1 2 1       1 1  Butanol CH 100 1 1 2 1 1 2 2 4 1 1  Butyl acrylate C H  0  100 1 2 4 2 3 4 4 4 1 1  Calcium chloride CaCl  alcoholic 1 4 2 3 1     4 1 3  Carbon disulphide CS  100 4 3 4 2 4 4 4 4 1 1  Carbon tetrachloride CCl  100 4 4 4 2 4 4 4 4 1 1   TETRA   Chlorine Cl  100 4 4 4 4 4 4 4 4 1 3  Chlorobenzene CHCl 100 3 4 4 1 3 4 4 4 1 1  Chloroform CHCI  100 3 3 4 4 3 4 4 4 1 3  Chlorine water Cl  x H0 3 4 4 4 3   3 3 1 4  Chrome alum
6.    2 1 1 Funktions  und Bedienelemente                65   2 1 2 Typenschild    66   2 2 WirkUNGSWEISC           0 00 cece eee casina nedi 66   2 2 1 Prinzip der Zentrifugation                      66   2 2 2 Anwendungsbereich  eee 67  2 2 2 1 Drehzahl  Radius  Relative   Zentrifugalbeschleunigung             67   2 2 2 2  DIChte u a 67   3  Sicherheit yi shoes tend ee en 68   3 1 Beschilderung des Ger  ts 0    cece eee 68   3 2 Symbol  und Hinweiserkl  rungen                     69   3 3 Verantwortung des Betreibers             222        69   3 4 Bedienpersonal enaiis mareni eee e eee ees 69   3 5 Informelle Sicherheitshinweise                        69   3 6 Sicherbeitahinwelse eee eee eee 70   3 6 1 Elektrische Sicherheit                           70   3 6 2 Mechanische Sicherheit                        70   3 6 3 Brandschutz    71   3 6 4 Chemische und biologische Sicherheit         71   3 6 5 Sicherheitshinweise zur Zentrifugation        71   3 6 6 Best  ndigkeit von Kunststoffen                72   3 6 7 Lebensdauer von Rotoren und Zubeh  r        72   3 7 Sicherheitseinrichtungen                  00  cence 72   3 7 1 Deckelveriegelung  ee eee 72   3 7 2 Systemkontrolle                    2222222000  73   3 8 Verhalten bei Gefahren und Unf  llen                 73   3 9  RestrisIKen u    a E EEN et rh EE IER EE 73   4  Lagerung und Transport    74   4 1 Abmessungen und Gewicht    74   4 2 Lagerbedingungen         iie 74   43 Transporthinweise           sss 74   4 4 Ver
7.    6 3 1   bersicht    6 3 2 Aufbau und konstruk   tive Sicherheitsma  nahmen    6 3 3 Antrieb    6 3 4 Bedienung und Anzeige    Zentrifugieren mit geringerer Kapazit  t  Die Aufteilung der Probengef    e muss symmetrisch erfolgen  so dass eine  gleichm    ige Belastung des Rotors erfolgt                    Abb  9  Zul  ssige Beladung eines Winkelrotors      Gef    e au  erhalb der Zentrifuge beladen  Fl  ssigkeiten in den Bohrungen  des Rotors verursachen Korrosion      Gef    e sorgf  ltig f  llen und gewichtsgleich anordnen  Bei Unwucht entsteht  erh  hter LagerverschleiB        Sicherheits  und Gefahrenhinweise beachten  siehe   Kapitel 3   Sicherheit       Die neue Generation der Laborzentrifugen von Sartorius Stedim Biotech GmbH ist  mikroprozessorgesteuert und mit kollektorlosen  ger  uscharmen und langlebigen  Asynchronmotoren ausgestattet     Das Problem des B  rstenwechsels entf  llt  und da kein Kohlenstaub entsteht  ist eine  Aufstellung in Reinr  umen m  glich  wenn entsprechendes Zubeh  r verwendet wird     Die Zentrifuge ist in einer soliden Druckgusskonstruktion eingebaut    Der Zentrifugendeckel besteht ebenfalls aus stabilem Druckguss und ist mit Kunst   stoffteilen verkleidet  Der Deckel wird hinten von einem stabilen Bolzen und vorn  vom motorischen Deckelschloss gesichert  So befindet sich um den Rotorraum  herum eine stabile Sicherheitskapsel     Als Antriebsmotor kommt ein Asynchronmotor zum Einsatz     Die Anzeige besteht aus einem hermetisch geschloss
8.    EE sartorius stedim    biotech    Operating Manual   Betriebsanleitung    CENTRISARTT A 14    Microcentrifuge   Mikrozentrifuge       UMC ANU TA 85032 533 94 Vers  03   2014       Contents of this Manual    Inhalt dieser Anleitung    Englebert bass Page 3    Deutsch  ae Seite 59    Centrisart   A 14       Contents    Special Notes    5  1  General Information    7  1 1 Importance of the Operating Manual                 7  1 2 Intended USE  6c cece eee neee 7  1 3 Warranty and Liability ee 7  1 4 Equipment Supplied                   0  cece 7  2  Layout and Mode of Operation                          9  2 1 Layout of the Centrifuge             22222eeeeeeeenn 9  2 1 1 Functional and Operating Elements            9  252 Name Plate eis EP Roues 10  2 2 Mode of Operation    10  2 2 1 Centrifugation Principle                        10  2 2 2 Area of Application  eee 11   2 2 2 1 Speed  Radius and Relative  Centrifugal Force    11  2222  enee TERRE 11  DEn EE 12  3 1 Marking of the Un  12  3 2 Explanation of the Symbols and Notes                13  3 3 Responsibility of the Uperator  13  3 4 Operating Personne    13  3 5 Informal Safety Instructions                          13  3 6 Safety Instruction    14  3 6 1 Electrical Safety          2222222cccecccccneen  14  3 6 2 Mechanical Safety 0    14  3 6 3 Fire Prevention             sssssssssssssssssss 15  3 6 4 Chemical and Biological Safety                 15  3 6 5 Safety Instructions for Centrifugation         15  3 6 6 Resista
9.    Immediately eliminate any problems that can affect safety     Safety 17       4 1 Dimensions and Weight    4 2 Storage Conditions    4 3 Shipping Instructions    4 4 Packaging    18    Storage and Transport    4  Storage and Transport    CENTRISART  A 14                   Height 176 mm  Height with open lid 310 mm  Width 212 mm  Depth 266 mm  Weight 6 kg    The centrifuge can be stored in its original packaging for up to a year        Store the centrifuge only in dry rooms        The storage temperature must be above  20  C         f you would like to store it for more than one year or if you intend to ship it  overseas  please contact the manufacturer       The centrifuge is not equipped with a transport safety device     When lifting the centrifuge  always reach under the centrifuge from the side        A    CAUTION     The centrifuge weighs approx  6 kg          For transport use suitable packaging and  if at all possible  the original packaging   see  gt  chapter 4 4  Packaging       The centrifuge is packaged in a cardboard box        Open the box        Take out the box containing the accessories        Lift the centrifuge with both foam cushions out of the cardboard box  When  lifting the centrifuge  always reach under the centrifuge from the side        CAUTION     The centrifuge weighs approx  6 kg          Retain the packaging for any possible future transport of the centrifuge        5 1 Installation Site    5 2 Power Supply    5 2 1 Connection    5 2 2 Customer
10.    Schrift nach oben               1 Tellerfeder          Abb  6  Rotorbefestigungsmutter von oben  A     und unten  B     6 2 2 2 Einsetzen des  Mikroh  matokrittellers        Zum Aufsetzen des Schnappdeckels den Sicherheitsverschluss in der Mitte  nach oben ziehen und den Deckel aufsetzen  Durch Loslassen des Sicherheitsver   schlusses wird der Deckel verriegelt        Einmal t  glich oder nach 20 Zyklen muss die Rotorbefestigungsmutter um  einige Umdrehungen gel  st  der Rotor kurz angehoben und wieder fixiert   WARNUNG  werden  Nur so ist eine ordnungsgem    e Verbindung zwischen Rotoraufnahme  und Motorwelle gew  hrleistet          Rotoren k  nnen ohne Deckel betrieben werden  Dies hat leicht erh  hte Laufger  u   sche und Temperaturen zur Folge       Sicherheits  und Gefahrenhinweise beachten  siehe   Kapitel 3    Sicherheit                   Abb  7  Mikroh  matokritteller  Best  Nr  11026  und Ablesekarte  Best  Nr  17028     Betrieb 7                   Abb  8  Rotorbefestigungsmutter von oben  A   und unten  B     6 2 2 3 Einsetzen von  Zubeh  r    78 Betrieb    Rotorbefestigungsmutter von der Motorwelle abschrauben    entgegen dem Uhrzeigersinn     Den Teller von oben senkrecht mit der Mittelbohrung auf die Motorwelle  aufsetzen    Rotorbefestigungsmutter im Uhrzeigersinn handfest anziehen  entspricht 1 Nm    Die Rotorbefestigungsmutter muss mit der Tellerfeder zum Mikroh  matokritteller  zeigen     Tellerfeder    Sicherheits  und Gefahrenhinweise beachten  siehe    
11.   1  o    Ri s  4 Zb A Y             2  SELECT SET START STOP  3  Ke er  1  Lid  key  2  Start   Stop  key  3  Set  arrow  4  Select  key  5 Display    From the control panel  the centrifuge is directly put into operation     The display then illuminates   The centrifuge is ready for operatio    Using this key  you can    start the centrifuge     n       cancel a planned deceleration process and restart the centrifuge     switch to short run  see   chapter 6 5 4 2  Short Run         prematurely end the centrifuge run     The centrifuge can start once the      lid is closed     Using this key  you can      activate editing mode       select the parameter to be changed     Using this key  you can      open the lid     This is only possible if the      centrifuge has not yet been started     Operation 25       6 4 1 4 Set Arrow Keys Use these keys to  1  in run mode    switch from speed indicator to RCF     2  in editing mode    change the parameters        6 4 2 Display                OPEN                   SELECT SET START STOP    Baie eee                1 Speed   RCF field  2 Field for acceleration   deceleration curves and run mode  3 Time field    The centrifuge display consists of three display fields   Speed and gravitational field are shown in the upper line  the runtime can be read  from the bottom line  the middle line indicates  soft stop  and  short run      6 5 Starting a The centrifuge is ready for operation when the mains power switch is on and the lid  Centrifuga
12.   or translated in any form or by   any means without the prior   written permission of Sartorius  Stedim Biotech GmbH    The status of the information  specifi   cations and illustrations   in this manual is indicated by   the date given below    Sartorius Stedim Biotech GmbH reser   ves the right to make changes to the  technology  features  specifications and  design of the equipment without noti   ce     Status    March 2014    Sartorius Stedim Biotech GmbH   Goettingen  Germany    Printed in the EU on paper bleached without chlorine    W  Publication No   SE 6048 a140305  Ver  03   2014    
13.  1 1  Quecksilber Hg 100 1 1 1 1 1 1 1 3 1 3  Quecksilber  Il  chlorid   HgCl  10 1 4 1 3 1 1 1 1 1 4  Resorcin CHA  5 1 4 2 3 1 4 2   1 2  Salpeters  ure HNO  10 1 4 1 4 1 1 1   1 3  Salpeters  ure HNO  100 4 4 4 4 4   4   1 1  Salzs  ure HCl 5 1 4 1 4 1 1 1   1 4  Salzs  ure HCl konz  1 4 4 4 1 1 2 3 1 4  Schwefelkohlenstoff CS  100 4 3 4 2 4 4 4 4 1 1  Schwefels  ure H SO  6 1 4 1 4 1 1 1   1 3  Schwefels  ure H SO  rauchend 4 4 4 4 4 4 4 4 1 3  Schwefelwasserstoff HS 10 1 1 1 1 1 1 1 3 1 1  Silbernitrat AgNO  100 1 1 1 1 1 1 1 1 1 4  Styrol Cl  100 4 1 4 1 3   4 4 1 1  Talg     100 1 1 1 1 1   1 1 1 1  Tetrachlorkohlenstoff   CC  100 4 4 4 2 4 4 4 4 1 1   TETRA   Tetrahydrofuran  THF    C H4O 100 3 1 4 1 3 4 4 4 1 1  Tetrahydronaphthalin   Cl  100 3 1 4 1 4 4 4 4 1 1  Thionylchlorid C1 50 100 4 4 4 2 4 4 4 4 1 3  Toluol CH  100 3 1 4 1 3 4 4 4 1 1  Transformatoren  l     100 1 1 3 3 1 1 1   1 1  Trichlorethan C H4CI  100 3 3 4 2 4 4 4 1 4  Urin     100 1 1 1 1 1   1 1 2  Wachse     100   1 1   1       1 1  Wasserstoffperoxid H 0 v 3 1 3 1 1 1 1 1   1 3  Wasserstoffperoxid H 0  30 1 4 1 4 1 1 1   1 3  Weine     100 1 1 1 2 1 1 1 1 1 4      bersicht    105       Bestandigkeiten bei 20   C      keine Angabe                      1 sehr gut bestandig t E 5  2 gut best  ndig        3 bedingt best  ndig z E s 2 P  4 unbest  ndi e 5 t     2 2 S  i S 35 SS Ze ZZ e g  5 DB   S E E SS 3 2 B  5 as E E       5       5    N s gt  5   2 E 2 2 232 355  S ro 2 2 2    2 2 2     amp   Mediu
14.  1 1 2 3 1 4  Hydrogen peroxide H 0 v 3 1 3 1 1 1 1 1   1 3  Hydrogen peroxide H O  30 1 4 1 4 1 1 1   1 3  Hydrogen sulphide HS 10 1 1 1 1 1 1 1 3 1 1  lron  Il  chloride FeCl  saturated 1 3 1 3 1 1 1 1 1 4  Isopropanol C3H0 100 1 1 1 1 1 1 1 4 1 2  lodine tincture l 1 4 3 1 1   4 4 1 1  Potassium hydrogen CHKO  saturated 1 1 2 1 1       1 4  carbonate  Potassium hydroxide KOH 30 1 1 4 3 1 1 1 1 1 4  Potassium hydroxide KOH 50 1 1 4 3 1 1 1 1 1 4  Potassium nitrate KNO  10 1 1 1 1 1       1 1  Potassium permanganate KMnO  100 1 4 1 1 1   1   1 1  Lactic acid CHA  3 1 3 1 2 1 1 2   1 1  Magnesium chloride MgCl  10 1 1 1 1 1 1 1 1 1 1  Mercuric  Il  chlorid HgCl  10 1 4 1 3 1 1 1 1 1 4  Mercury Hg 100 1 1 1 1 1 1 1 3 1 3  Methanol CH O 100 1 2 4 1 1 3 1 3 1 1  Methylethylketone  MEK  CHA 100 1 1 4 1 1 4 4 4 1 1  Mineral oil     100 1 1 1 1 1 1 1   1 1    48 Overview       The data refer to resistance at 20  C                                                                                                                   no data T x    1 resistant     E  2 practically resistant u di Ai E  3 partially resistant o    bl fy S   P  4 not resistant    ee s    5 o     3   E fi  BOR OR PR 2 i 5 sz     zs o      PS          P2 c a  Medium Formula  vo  HDPE PA PC POM PP PSU PVC PVC PTFE AL  n heptane CH 100 2 1 1 1 2 1 2 4 1 1  n hexane Ct H4 100 2 1 2 1 2 1 2 4 1 1  Nitric acid HNO  10 1 4 1 4 1 1 1   1 3  Nitric acid HNO  100 4 4 4 4 4   4   1 1  Nitrobenzene C H NO  100 3 4 4 3 2 4 
15.  1 set   BBI 8586098 Reaction vials 2 2 ml  100 pcs   1 set   BBI 8580910 Reaction vials 0 2 ml  100 pcs   1 set    Accessories for microhaematocrit capillaries                         Part no  Description Maximum Max  gravi   speed tational field   min    xg   BBI 8583501 Microhaematocrit rotor incl  lid  suitable 13 000 11 903  for 24 capillary tubes    1 4 x 50 mm   35 yl no  15028  including reader 17028   can be combined with reader no  17026  BBI 8587272   Microhaematocrit capilaries  heparinized   35 ul    1 4 x 50 mm  200 pcs    1 set  BBI 8584885 Rubber ring for microhaematocrit rotor  BBI 8583501  BBI 8586837 Capillary sealing compound  12 plates   BBI 8587299 Reader for haematocrit rotor 11026  DCCO304W K   VoluPAC tubes for determination of  cell mass  PCV   50 pcs   1 set  DCC0O304W S   VoluPAC tubes for determination of    cell mass  PCV   200 pcs   1 set    Further accessories available on request           Possible maximum speeds of vessels   Some vessels such as centrifuge tubes  micro tubes  culture tubes  polyfluor  tubes and especially vessels with large capacity can be driven at higher speeds  than their breaking point in our rotors  buckets and adapters  We recommend  that the vessels always be filled up and to follow the recommendations of the  vessel manufacturer           10 7 Declaration of  Decontamination   Return  Form    The enclosed declaration is for the safety and health of our employees  Fill out and  include the forms when returning centrifu
16.  118 30 40 20  Polypropylene copolymer tubes 115 121 30 40 20  Polypropylene rectangular carriers 115 118 30 40    Polypropylene round carriers 115 118 30 40    Polysulfone lids for angle rotors 134 138 3 5 100  Polysulfone caps for buckets 134 138 3 5 100  PTFE tubes 134 138 3 5 100  Polypropylene balance adapter for blood  115 118 30 40 ns   bag systems  Stainless steel balance weight for blood  121 30 30 n s     bag systems       8 3 Service    36    A    WARNING     In the event of service work that requires the removal of the panels  there is a  risk of electric shock or mechanical injury  Only qualified specialist personnel is  authorized to perform this service work        The centrifuge is subject to high mechanical stress  In order to be able to withstand  this high level of stress  high quality components were used during the production of  the centrifuge  Nevertheless  wear cannot be excluded and it may not be visible from  the outside  Especially the rubber parts that are   among other things   part of the  motor suspension  are subject to ageing     This is why we recommend having the centrifuge checked by the manufacturer  during an inspection once per year in the operating state and once every three years    in the dismantled state  Rubber parts should be replaced after three years     This service can also be arranged as part of a maintenance contract             If you would like to utilize our service  please state the type of your  centrifuge and its serial
17.  2 g cm  the maximum  permissible speed of the centrifuge is reduced based on the following formula            N   naas X4  2  Rho    A    Rho   density in g cm     As an additional aid  the enclosed speed gravity field diagram is provided   see  gt  chapter 10 8 Speed Gravitational Field Diagram      Most errors can be resolved by powering off   on  In the case of a brief power failure  during centrifugation  this is interrupted and can be reopened by opening the lid and  pressing the  Start   Stop  key again to start                 No indication on the display Measures   Is the socket live  Check fuse in the mains supply   Power cord plugged in and voltage present  Firmly insert the power plug   Power switch on  Switch on the power    Lid closed  Close the lid        10 3 1 Centrifuge Cannot be  Started    10 3 2 Centrifuge  Decelerates During Operation    10 3 3 Emergency Lid Release       The set speed value is displayed  in anunchanged manner    Power off   on  If the error occurs again  contact  service       Open and close the lid again   If the error persists despite the locked lid  call  service        Centrifuge shows an error from  groups 1 to 18 after restart     Power off   on  If the error occurs again  contact  service   see  gt  chapter 10 4 1 Table of Error Codes         Error 19    Acknowledge by pressing the lid key     In the event of a power failure  it is possible to manually open the centrifuge lid with  a socket spanner  included in the equipment supp
18.  7 1 Lid Lock Device The centrifuge can only be started when the lid is properly closed  The electrical lock  must be locked  The lid can only be opened when the rotor has stopped  If the lid is  opened by way of the emergency release system during operation  see  gt  chapter  7 1 1  Emergency Lid Release    the centrifuge will immediately switch off and  decelerate brakelessly  If the lid is open  the drive is completely separated from the  mains power supply  i e  the centrifuge cannot be started     16 Safety       3 7 2 System Check An internal system check monitors the data transfer and sensor signals with regard  to plausibility  The system continuously performs self monitoring and detects faults   Malfunctions are indicated by error messages with a number in the speed   RCF  display  see   chapter 7 2  Table of Error Codes             3 8 Measures in the Event   If an emergency arises  switch off the centrifuge immediately   of Hazards and Accidents   If in doubt  call the emergency doctor   WARNING   3 9 Remaining Hazards The centrifuge was built state of the art and according to the accepted safety rules     However  danger to life and limb of the operator  or of third parties or impairments  of the unit or other material assets cannot be completely excluded when the unit is  being used       Use the centrifuge only for the purpose that it was originally intended for    see  gt  chapter 1 2  Intended Use         Use the unit only if it is in a perfect running state  
19.  8581410  Part No  _  Ref  usine E  Normen EN 61010 2 020  Standards EN 61000 3 2  EN 61000 3 3  Normes EN 61326  NA  A  sy  Datum   Unterschrift   Date   Signature   Date   Signature 03 09 2007          Fabr  Nr    Serial No    Num  ro de fabrique    R  Vogt   Managing Director       Statement of Conformity    51             UCB   01 08    CERTIFICADO   CERTIFICAT    LL  r  cc  e  LL      EC  LU  GA  LJ  r    t  x  Lu   gt   o     2  N          CERTIFICATE ke    No  U8 12 05 75349 005    Holder of Certificate  Sartorius Stedim Biotech GmbH  August Spindler Str  11          37079 G  ttingen  GERMANY  Production 12211  Facility ies    Certification Mark   Product  Laboratory Centrifuges  Model s   Centrisart A 14  Parameters  Rated voltage  100 120V AC 220 240V AC  Raled frequency  50   60 Hz 50   60 Hz  Raled power  95W  Protection class  I  Degree of protection  IP 20  Max  speed  14800 rpm  Depth  266 mm  Width  212 mm  Height  176 mm  Weight  6 kg  Tested UL 61010 1 2004    according to  IEC 61010 2 020 2006      CANICSA C22 2 No 61010 1 2004  CANICSA C22 2 No  61010 2 020 2009    The product was voluntarily tested according to the relevant safety requirements noted above  It  can be marked with the certification mark above  The mark must not be altered in anyway  This  product certification system operated by TUV SUD America Inc  most closely resembles system  3 as defined in ISO IEC Guide 67  Certification is based on the TUV SUD  Testing and  Certification Regulations  
20.  KCr SO    x 12H 0 saturated 1 2 1 3 1 1   1 3  Chromic acid CrO  10 1 4 2 4 1 1   1 1  Citric acid C H 0  10 1 1 1 2 1 1 1 1 1  Citric acid CHA  50 1 3 1 2 1       1 1  Copper sulphate CuSO  x 5H 0 10 1 1 1 1 1 1 1 1 1 4  Cyclohexanol C H  0 100 1 1 3 1 1 1 1 4 1 1  Decane CioH22 100   1 2 1 3       1 1  Diesel oil     100 1 1 3 1 1   1 3 1 1    Overview    47       The data refer to resistance at 20  C                                                                                                                no data T x    1 resistant     E  2 practically resistant u Ai       3 partially resistant      b     v  4 not resistant    oe S    S vo     3   E fpg P P P D ro p     amp    t re E           9    E     Medium Formula  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL  Dimethylanilin CHN 100   3 2 4     1 1  Dimethylformamide C4 D NOv 100 1 1 1 1 4 3 1 1   DMF   Dimethylsulfoxide C H SO 100 1 2 4 1 1 4 4   1 1   DMSO   Dioxane C H 0  100 2 1 4 1 3 2 3 4 1 1  Ethanol C H O 96 1 1 1 1 1 1 1 3 1 1  Ethyl acetate C H 0  100 1 1 4 1 1 4 4 4 1 1  Ethylenchloride C H  Cl  100 3 3 4 1 3 4 4 4 1 1  Ethylene chloride CH Cl  100 4 3 4 3 3 4 4 4 1 1  Ethylendiamine CHN  100 1 1 3 1 1   3 4 1 1  Ethylether CH  100 3 1 4 1 4 4 4 4 1 1  Formaldehyde solution CH O 30 1 3 1 1 1       1 1  Formic acid CH 0  100 1 4 3 4 1 3 3 1 1 1  Furfurol C H 0  100 1 3 3 2 4       1 1  Glycerine C H 0  100 1 1 3 1 1 1 1 2 1 1  Hydrochloric acid HCl 5 1 4 1 4 1 1 1   1 4  Hydrochloric acid HCl conc  1 4 4 4
21.  Max  kin  energy  Nm     14 800  200   48  16 163  2   1 721       Other parameters          Time range 10 sec to 99 min 59 sec  short run   continuous run   Phys  data   Depth  mm  266   Width  mm  212   Height  mm  176   Weight  kg  6 0   EMC as per EN 61326 Class B   Noise level  dBA     60   Obligation to inspect no        The figures are valid for an ambient temperature of  23  C  2  C and a nominal    voltage of   10 96           At a nominal voltage of 100V or 200V  a tolerance of  10     5             For indoor use only         Allowable ambient temperature  5  C to   40  C     Max  relative humidity of air 80  up to 31  C with a linear decrease to 50     relative humidity of air at 40  C         Maximum altitude 2 000 m above sea level     Overview 39       10 2 Formulas    Mathematical Relation    10 2 1 Relative Centrifugal  Force  RCF     10 2 2 Density    10 2 3 Speed Gravitational   Field Diagram    10 3 Troubleshooting    40 Overview    The parameters speed  RCF and the group rotor and radius cannot be specified  independently  They are linked by the formula     RCF   11 18 x 10    x r x n     If two values are entered  the third value is determined by way of the stated formula   If the speed or the centrifugal radius are changed  the resulting RCF will be  recalculated  If the RCF is changed  the speed is adjusted accordingly using the  radius     r   radius in cm  n   speed in min      RCF unitless    If the density of the liquid to be centrifuged is above1
22.  USA    www TUVamerica com Tuv         108       NRTL Zertifikat          11  Stichwortverzeichnis    Adaptoren  Anrisse  Anschlusskabel  Anschlussleistung  Antrieb  Anzeigefeld  Arbeitssicherheit  Aufstellort  Autoklavieren    Bedienelemente   Bel  ftung   Beschleunigungszeit  Best  ndigkeit von Kunststoffen  Best  ndigkeitstabelle  Bestimmungsgem    e Verwendung  Betriebssicherheit  Betriebsspannung   BGR 500   Bremszeit    Chemische Reaktionen    Dauertemperaturbest  ndigkeit  Deckelverriegelung  Dekontaminationsmittel  Desinfektion  Desinfektionsmittel   Dichte   Druckkorrosion    Einlagerung  Elektr  Anschluss  Elektronik  Emissionen  Entsorgung    Fehlermeldung  Funkentst  rt    Gefahrenhinweise  Gefahrenstoffe  Ger  uschpegel  Gewicht  Glasbruch  Glassplitter    100   72   63   95   72  79  82   69  101  75   91    81  75  84  72  103  63  89  75  69  84    90    91  72  80  89  91  91  67  90    74  75 ff   80  71  94    86  95    62  71  95  74 95  91  91    H  chstdrehzahlen von Gef    en    Inbetriebnahme  IP Code    Kapillaren  Kondenswasser  Konformit  tserkl  rung  Kontamination  Korrosion  Korrosionsschutz  l  Kurzlauf  Kurzzeitbetrieb    Lagertemperatur   Laufmodus   Lebensdauer von Rotoren und Zubeh  r  Leistungsaufnahme   Leistungsdaten   L  semittel   Luftfeuchte   L  ftungs  ffnungen    Materialabtragung  Mikroh  matokritrotor  Motorlager  Motorwelle    Nennspannung  Netzschalter  Netzsicherung  Netzstecker    Parameter    Reinigungsmittel  Restrisiken   R
23.  ber den Zusammenhang von Drehzahl  Radius und RZB liefert  das Drehzahl Schwerefeld Diagramm  siehe    Kapitel 10 8  Drehzahl Schwerefeld   Diagramm       Die Angaben zur Drehzahl von Rotoren und Zubeh  r beziehen sich auf Fl  ssigkeiten  mit einer Dichte  die geringer ist als 1 2 g cm   Liegt die Dichte der Fl  ssigkeit     ber diesem Wert  verringert sich die maximal zul  ssige Drehzahl der Zentrifuge  nach folgender Formel     n   Nmax x    1 2 Rho    Rho   Dichte in g cm     Aufbau und Wirkungsweise 67       3 1 Beschilderung    des Ger  ts    68    Sicherheit    3  Sicherheit    An den Zentrifugen werden folgende Symbole verwendet        Gef  hrliche elektrische Spannung  Dangerous voltage  Courant haute tension       Achtung  Betriebsanleitung lesen  Attention  consult the instruction manual  Attention  consulter le mode d   emploi       Ein  Netzverbindung   On  Power   Marche  mise sous tension        Aus  Netzverbindung   Off  Power   Arr  t  mise hors tension        Schutzleiteranschluss  Protective earth  ground   Raccord a la terre           eo p gt     Erde  Earth  ground   Terre          Netzstecker ziehen  Unplug the mains plug  Debrancher la prise       Vorsicht Quetschgefahr  Caution  Risk of bruising  Attention   Risque de blessure       Drehrichtungspfeil  Arrow indicating the direction of rotation  Fleche de sens de rotation       Hei  e Oberfl  che  Hot surface  Surface chaude       CE Zeichen gem     Richtlinie 2006 42 EG  CE mark in compliance with the
24.  dass die Zentrifuge  ordnungsgem     aufgestellt und installiert ist  siehe  gt  Kapitel 5    Aufstellung  und Anschluss            OPEN        Netzschalter bet  tigen     Beim Einschalten der Zentrifuge leuchten kurzzeitig alle Segmente des Displays   Die Betriebsbereitschaft ist hergestellt     Der Deckel kann ge  ffnet werden  wenn die Zentrifuge zum Stillstand gekommen ist       Deckel Taste dr  cken  um den Deckel zu   ffnen     Bei ge  ffnetem Deckel ist ein Start der Zentrifuge nicht m  glich       Zum Schlie  en mit beiden H  nden leicht auf den Deckel dr  cken  bis das Deckel   schloss verriegelt        VORSICHT     Beim Schlie  en des Deckels niemals zwischen Deckel und Geh  use greifen   Quetschgefahr           1 Sicherheitsverschluss  2 Rotordeckel  3 Rotorbefestigungsmutter    4 Motorwelle  i 5 Winkelrotor    2      1          1     A    N    t    i    3                zr L Abb  5  Einsetzen und Befestigen   Seng  des Rotors    ex                    Zentrifugendeckel mit der Deckeltaste   ffnen     Rotorbefestigungsmutter von der Motorwelle abschrauben   entgegen dem Uhrzeigersinn        Rotor von oben senkrecht mit der Mittelbohrung auf die Motorwelle aufsetzen     Rotorbefestigungsmutter im Uhrzeigersinn handfest anziehen  entspricht 1 Nm    Die Rotorbefestigungsmutter muss mit der Tellerfeder zum Rotor zeigen     Rotorbefestigungsmutter im Uhrzeigersinn handfest anziehen  entspricht 1 Nm    Die Rotorbefestigungsmutter muss mit der Tellerfeder zum Rotor zeigen
25.  directive 2006 42 EC  Symbole CE conforme    la directive 2006 42 CE       AP lp    Nicht mit dem Hausm  ll entsorgen  Do not dispose as part of domestic waste  Ne pas jeter avec les d  chets m  nager          3 2 Symbol  und  Hinweiserklarungen    3 3 Verantwortung des  Betreibers    3 4 Bedienpersonal    3 5 Informelle  Sicherheitshinweise    In der Betriebsanleitung werden folgende Benennungen und Zeichen f  r  Gef  hrdungen verwendet        WARNUNG     Dieses Symbol bedeutet eine m  gliche drohende Gefahr f  r das Leben und   die Gesundheit von Personen  Das Nichtbeachten dieser Hinweise kann schwere  gesundheitssch  dliche Auswirkungen zur Folge haben  bis hin zu lebensgef  hr   lichen Verletzungen        VORSICHT     Dieses Symbol bedeutet eine m  gliche gef  hrliche Situation   Das Nichtbeachten dieser Hinweise kann leichte Verletzungen zur Folge haben  oder zu Sachbesch  digungen f  hren              Dieses Symbol deutet auf wichtige Sachverhalte hin        Der Betreiber verpflichtet sich  nur geeignetes Personal an der Zentrifuge arbeiten  zu lassen  siehe P Kapitel 3 4  Bedienpersonal       Die Zustandigkeiten des Personals f  r das Bedienen  Warten und Instandhalten sind  klar festzulegen     Das sicherheitsbewusste Arbeiten des Personals unter Beachtung der Betriebsan   leitung und die Einhaltung der EG Richtlinien zum Arbeitsschutz  nationaler Gesetze  zum Arbeitsschutz und der Unfallverh  tungsvorschriften muss in regelmaBigen  Abstanden  z B  monatlich    berp
26.  number     Please use the request form on our website        Maintenance and Service       8 4 Return of Defective Parts    8 5 Maintenance    Although we exercise great care during the production of our products  it may be  necessary to return a unit or accessory to the manufacturer     In order to ensure the quick and economical processing of returns of centrifuges   spare parts or accessories  we require complete and extensive information concerning  the process  Please fill in the following forms completely  sign them  enclose them  with the return package and send them together with the product     1  Declaration of decontamination   As a certified company and due to the legal regulations for the protection of our   employees and of the environment  we are obliged to certify the harmlessness of all   incoming goods  For this purpose  we require a declaration of decontamination        The form must be filled in completely and signed by authorized and specialized  personnel only        Affix the original form in a clearly visible manner to the outside of the packaging           If no such declaration is enclosed in the return package  we will perform the  decontamination at your expense        2  Form for the return of defective parts   This form is for the product related data    It facilitates the assignment  and enables the quick processing of the return  If several   parts are returned together in one packaging  please enclose a separate problem   description for ever
27.  provided  Fuses    5  Set up and Connection    Operate the centrifuge only in closed and dry rooms    All the energy supplied to the centrifuge is converted into heat and emitted to the   ambient air        Ensure sufficient ventilation        Keep a safety distance of at least 30 cm around the centrifuge so that the vents  in the centrifuge remain fully effective      Do not subject the centrifuge to thermal stress  e g  by positioning it near heat  generators      Avoid direct sunlight  UV radiation          he table must be stable and have a solid  even surface        IMPORTANT        During transport from cold to warmer places  condensational water will collect  inside the centrifuge  It is important to allow sufficient time for drying  min   24 h  before the centrifuge can be used again              A    WARNING        The operating voltage on the name plate must correspond to the local supply  voltage          Sartorius micro centrifuges are units of safety class    The centrifuges of the type  1 14 have a three wire power cord with an IEC C 13 connector     Typically  the centrifuge must be protected with 16 Amp L or B fuses that are to be  provided by the customer     Set up and Connection    19       6  Operation       6 1 Initial Startup      CAUTION     Before the initial start up  please ensure that your centrifuge is properly set up  and installed  see  gt  chapter 5    Set up and Connection          6 2 Switching on the  Centrifuge    6 2 1 Opening and Closing 
28.  the Lid    OPEN        Press the mains power switch   The display then illuminates     The centrifuge is ready for operation     The lid can be opened if the centrifuge is at a standstill       Press the lid key in order to open the lid     The centrifuge cannot be started if the lid is opened       To close  press with both hands slightly on the lid until the lid lock is locked        A       CAUTION     Do not place your fingers between the lid and the housing when closing the lid   Risk of crushing        6 2 2 Installation of Rotors  and Accessories    6 2 2 1 Installation of the  Rotor    20 Operation       1 Safety lock  2 Snap on lid  3 Rotor fastening nut  4 Motor shaft  5 Angle rotor                   Fig  5  Installation of rotor and          rotor lid                         Fig  6  Rotor fastening nut from above  A  and    below  B     6 2 2 2 Installation of  Microhaematocrit Rotor    Open the centrifuge lid by pressing the lid key    Unscrew the rotor fastening nut from the motor shaft  counterclockwise    Lower the rotor with its central bore straight down onto the motor shaft   Hand tighten the rotor fastening nut clockwise  corresponds to 1 Nm    The rotor fastening nut and conical spring washer must face the rotor   Hand tighten the rotor fastening nut clockwise  corresponds to 1 Nm    The rotor fastening nut and conical spring washer must face the rotor   i e  the writing must be shown on top           Conical spring washer        To lock the snap on lid  
29. 040  incl  polysulfone lid no  17882   BBI 8583471 Angle rotor made of polypropylene  18 x 1 5  2 2 ml  for e g  14 800  reaction vials no  15008  15040  or 18 x 0 24   0 4 ml  e g  no   15014   2 lines  incl  polysulfone lid no  17882  Radius max  radius min  15 673  6 4 cm 3 2 and 2 5 cm 14 448  5 9 cm 3 6 and 2 5 cm   BBI 8583480 Angle rotor made of polypropylene  24 x 1 5 2 2 ml  for reaction 14 800 16 163  vials  e g  no  15008  15040  incl  polysulfone lid no  17882   BBI 8581703 Angle rotor made of polypropylene  for 2 PCR strips with 8 tubes 14 800 11 755  0 2 ml e g no  15042  incl  polysulfone lid no  17882   BBI 8583498 Replacement lid  polysulfone  for CENTRISART  A 14 angle rotors    10 6 Rotor Radii    The information in the accessories table concerning the radius refers to the values of    the respective rotor as shown below  The radius calculation is described in chapter    2 2 2 1    Speed  Radius and Relative Centrifugal Force         Rmin    Rmax                Fig  13     Minimum and maximum radius of an angle rotor     Fig  14   Microhaematocrit rotor    Overview    43       44    Overview    Adapters and Plastic Tubes                         Part no  Description   BBI 8585415 Adapter for reaction vials 0 2544   0 4 ml  e g  no  15014  BBI 8586179 Adapter for reaction vials 0 5 0 75 ml  e g  no  15005  BBI 8589917 Adapter for PCR tubes 0 2 ml  e g  no  15042  BBI 8588317 Reaction vials 0 5 ml  100 pcs   1 set   BBI 8586225 Reaction vials 1 5 ml  100 pcs  
30. 2 ml f  r ReaktionsgefaBe z B  15008  14 800  15040 oder 18 x 0 25 0 4 ml f  r Reaktionsgef    e z B  15014   2 Reihen  Winkel 42   48    einschl  Polysulfondeckel 17882 15 673  max  Radien min  Radien 14 448  6 4 cm 3 2 und 2 5 cm  5 9 cm 3 6 und 2 5 cm   BBI 8583455 Winkelrotor 24 x 1 5   2 2 ml  f  r z B  Reaktionsgef    e Nr  15008  14 800 16 163  15040  einschl  Deckel aus Polysulfon Nr  17882   BBI 8581096 Winkelrotor 16 x 1 5   2 2 ml  f  r z B  Reaktionsgef    e Nr  15008  14 800 15 673  15040  oder 16 x 0 5  0 75 ml z B  Nr  15005   2 Reihen  einschl  13 713       Deckel aus Polysulfon Nr  17882       max  Radien min  Radien  6 4 cm 3 4 und 2 4 cm  5 6 cm 3 2 und 2 4 cm  BBI 8583463 Winkelrotor aus Polypropylen  12 x 1 5   2 2 ml  f  r z B  Reaktions  14 800 15 183    gef    e Nr  15008  15040  einschl  Deckel aus Polysulfon Nr  17882    BBI 8583471 Winkelrotor aus Polypropylen  18 x 1 5  2 2 ml  f  r z B  Reaktions  14 800  gef    e Nr  15008  15040  oder 18 x 0 24   0 4 ml z B  Nr  15014    2 Reihen  einschl  Deckel aus Polysulfon Nr  17882             max  Radien min  Radien 15 673  6 4 cm 3 2 und 2 5 cm 14 448  5 9 cm 3 6 und 2 5 cm   BBI 8583480 Winkelrotor aus Polypropylen  24 x 1 5   2 2 ml  f  r z B  Reaktions  14 800 16 163  gef    e Nr  15008  15040  einschl  Deckel aus Polysulfon Nr  17882   BBI 8581703 Winkelrotor aus Polypropylen  f  r 2 PCR Streifen mit je 8 Gef    en 14 800 11 755    0 2 ml z B  Nr  15042  einschl  Deckel aus Polysulfon Nr  17882  BBI 
31. 4 4 1 1  Oleic acid CigH340  100 1 1 1 2 1   1   1 1  Oxalic acid C H50  x 2H 0 100 1 3 1 4 1 1 1 1 1 1  Ozone 0  100 3 4 1 4 3 1 1   1 2  Petroleum     100 1 1 3 1 1 1 1 3 1 1  Phenol C H O 10 1 4 4 4 1 4 1 3 1 1  Phenol C H 0 100 2 4 4 4 1 3 4 3 1 1  Phosphorus PCI  100   4 4 4 1   4 4 1 1  pentachloride  Phosphoric acid H PO  20 1 4 2 4 1       1 4  Pyridine CHA 100 1 1 4 1 3 4 4 4 1 1  Resorcin Cla   5 1 4 2 3 1 4 2   1 2  Sllver nitrate AgNO  100 1 1 1 1 1 1 1 1 1 4  Sodium bisulphite NaHSO  10 1 1 2 4 1       1 1  Sodium carbonate Na CO  10 1 1 1 1 1       1 3  Sodium chloride NaCl 30 1 1 1 1 1 1 1 1 1 3  Sodium hydroxide NaOH 30 1 1 4 1 1 1 1 1 1 4  Sodium hydroxide NaOH 50 1 1 4 1 1 1 1   1 4  Sodium sulfate Na S0  10 1 1 1 1 1 1 1 1 1 1  Stannous chloride SnCl  10 1 4 2 2 1       1 4  Styrene C H  100 4 1 4 1 3   4 1 1  Suet     100 1 1 1 1 1   1 1 1  Sulphuric acid H SO  6 1 4 1 4 1 1 1   1 3  Sulphuric acid H SO  fuming 4 4 4 4 4 4 4 4 1 3  Tetrahydrofuran  THF    C H4O 100 3 1 4 1 3 4 4 4 1 1  Tetrahydronaphthalene   Col  100 3 1 4 1 4 4 4 4 1 1  Thionyl chloride C1 50 100 4 4 4 2 4 4 4 4 1 3  Toluene C H  100 3 1 4 1 3 4 4 4 1 1  Transformer oil     100 1 1 3 3 1 1 1   1 1  Trichlorethane CHOCO  100 3 3 4 2 4 4 4 1 4  Urine     100 1 1 1 1 1   1 1 2  Urine CH N O 10 1 1 1 1 1     3 1 1    Overview    49       The data refer to resistance at 20  C                   no data T      1 resistant    gt  D  2 practically resistant u Ai       R z E          3 partially r
32. 8583498 Ersatzdeckel  Polysulfon  f  r Winkelrotoren der CENTRISART  A  14       10 6 Radien der Rotoren Die Angaben zum Radius in der Zubeh  rtabelle beziehen sich auf die  dargestellten Werte des jeweiligen Rotors  Die Berechnung des Radius ist in Kapitel  2 2 2 1  Drehzahl  Radius  Relative Zentrifugalbeschleunigung  beschrieben        Rmin    Rmax             Abb  13  Abb  14   Minimal  und Maximalradius eines Winkelrotors Mikroh  matokritteller      bersicht 99       100    Ubersicht    Adaptoren und Kunststoffgef    e                         Bestell Nr  Beschreibung   BBI 8585415 Adapter f  r Reaktionsgef    e 0 25100   0 4 ml z  B  Nr  15014  BBI 8586179 Adapter fiir ReaktionsgefaBe 0 5 0 75 ml  z  B  Nr  15005  BBI 8589917 Adapter f  r PCR R  hrchen 0 2 ml  z  B  Nr  15042  BBI 8588317 Reaktionsgef    e 0 5 ml  100 St  ck  1 Packung   BBI 8586225 Reaktionsgef    e 1 5 ml  100 St  ck  1 Packung   BBI 8586098 Reaktionsgef    e 2 2 ml  100 St  ck  1 Packung   BBI 8580910 Reaktionsgef    e 0 2 ml  100 St  ck  1 Packung    Zubeh  r f  r Mikroh  matokritkapillaren                         Bestell Nr  Beschreibung H  chst  Max   drehzahl Schwerefeld   min   xg   BBI 8583501   Mikroh  matokritrotor einschl  Deckel 13 000 11 903  geeignet f  r 24 Kapillaren    1 4 x 50 mm   35 yl Nr  15028  einschl  Ablesekarte  17028  kombinierbar mit Ablesescheibe  Nr  17026  BBI 8587272   Mikroh  matokritkapillaren  heparinisiert   35 yl 1 4 x 50 mm  200 St  ck   1 Packung  BBI 8584885   Gum
33. Anwender beim Hersteller zu vergewissern   dass das Verfahren die Zentrifuge nicht sch  digt      Beim Autoklavieren die Dauertemperaturbest  ndigkeit der einzelnen Materialien  beachten  siehe  gt  Kapitel 8 2 1  Autoklavieren          Fragen Sie im Zweifelsfall beim Hersteller an           WARNUNG        Bei Verwendung von Gefahrenstoffen  z B  infekti  se und pathogene  Substanzen  besteht die Pflicht zur Desinfektion der Zentrifuge und  des Zubeh  rs        Die Lebensdauer des Zubeh  rs h  ngt prim  r von der H  ufigkeit des Autoklavierens   und der Benutzung ab        Zubeh  r bei ersten Anzeichen farblicher Ver  nderungen  Strukturver  nderungen   Undichtigkeiten etc  unverz  glich austauschen      Beim Autoklavieren unbedingt darauf achten  dass die Verschlussdeckel nicht auf  die Gef    e aufgeschraubt sind  um ein Verformen der Gef    e zu vermeiden        Es kann nicht ausgeschlossen werden  dass sich Kunststoffteile  z B  Deckel oder  Gestelle  beim Autoklavieren verformen        Wartung und Instandhaltung 91       8 3 Instandhaltungs     arbeiten    92                                                    Zubeh  r max  Temp  min  max  max      C  Zeit Zeit Zyklen  Aluminiumbecher 134 138 3 5    Aluminiumrotoren 134 138 3 5    Glasgef    e 134 138 3 40    Gummieins  tze 115 118 30 40    Polyallomer und Polykarbonat  115 118 30 40    Rechteckgestelle  Polyallomer und Polykarbonat  115 118 30 40    Rundgestelle  Polykarbonat   Polyallomer Deckel 115 118 30 40 20  f  r W
34. CF    display     In the event of a fatal error  e g  a defective lid lock   a certain safety time will be  counted down on the display  During this time   ERR  and  SAFE  flash alternately on    the display  When the time is up   OFF  will be displayed           A    WARNING        Do not switch the centrifuge off until    OFF    is displayed  This is necessary in  order to ensure that the rotor is at a complete standstill        30 Malfunctions and Error Correction        Eliminate the source of the problem  see tables below        Acknowledge the error messages with the lid key     Type of error    Possible reason    Correction       No indication on  the display    No power in the mains  supply    Check fuse in the mains  supply       Power cord is not  plugged in    Plug in power cord correctly       Mains power switch off    Switch mains power  switch on       Lid is not closed correctly    Close the lid       Centrifuge cannot be  started  The set speed  value is displayed in an  unchanged manner    Several    Power off   on  If the error  occurs again  contact  service       The lid lock is not closed  correctly    Open and close lid  If the  error occurs again  contact  service          Centrifuge decelerates Several Power off   on  If the error  during operation and occurs again  contact  displays an error from service   1 to 18 after powering on   Centrifuge decelerates Several Ouit by pressing the lid key    during operation and  displays error 19 after  powering 
35. Kapitel 3  Sicherheit       Bedienung    Die Kapillaren mit Blut f  llen und diese einseitig mittels Kitt oder Verschmelzung  verschlie  en    Die Kapillaren in die Tellervertiefungen einlegen  verschlossene Seite gegen den  Gummiring  Die Kapillaren m  ssen dicht am Gummiring anliegen  Grunds  tzlich  gegen  berliegende Pl  tze best  cken    Rotordeckel mittels Schnappverschluss aufsetzen und verriegeln   Zentrifugendeckel schlie  en    Parameter eingeben  Drehzahl 13000 min    Schwerefeld RZB max  11903 x g   Zeit ca  5 min    Zentrifuge starten    Nach Stillstand des Rotors   ffnet der Zentrifugendeckel automatisch   Rotordeckel durch Bet  tigen des Schnappverschlusses entriegeln und den  Deckel abheben     Auswertung    Ablesescheibe auf den Mikroh  matokritteller aufsetzen    Durch Verdrehen der Ablesescheibe und Feineinstellung mittels des zentralen Ex   zenters werden der O Punkt und der maximale Fl  ssigkeitspunkt in den   Kapillaren fixiert  So kann der Prozentsatz abgelesen werden    Kapillaren entnehmen  Einzelne Kapillaren sind mit der Ablesehilfe auch au  erhalb  des Rotors auszuwerten  siehe auch Gebrauchsanweisung auf der R  ckseite der  Ablesehilfe      F  r den eingesetzten Rotor nur geeignete Gef    e verwenden  siehe  gt  Kapitel   11 1  Zubeh  rprogramm      Grunds  tzlich immer die gegen  berliegenden Pl  tze der Rotoren mit gleichem Zu   beh  r und gleicher F  llung besetzen  um Unwucht zu vermeiden        6 2 2 4 Gef    e    6 3 Zentrifugenbeschreibung 
36. S  a  FI kA   Apa   SSES  Se  SE  wu  GC  Ggs  E  E    Zz  A   LA  CG  Eege    AAA WANN A MA UN  LANMAMN AAR A VAAL A AY    Hal  du Di IH  Il Ihr   T ng          KUN AAV A    A AAANNAAAAN    au ni   2    ii Me  il  Hr Go  pm m d  12 ie   i  si    H     t  p    Sin MM    iih e     d N  WANN   AAA MAAN    VANNS  ay    TLLA ODODO EET    WAS AAA VO ALAS DON    BEI LEGLLLELUUEUE LLLI    i H  NEN TTT    ll      LETT   VOTI UH SEENEN    Il      INN AN AA  NN NA    NN NN d   ANAAANMAAAK N AAAKNMAAAA A V    HHE TT IHN  a    Z ET                           en Il             UR    Speed gravitational field diagram  EZ on the radius of the m              rehzahl  Schwerefeld Diagrama in  Abh  ngigkeit vom Radius der Rotoren    am  INI TTC          Ubersicht 101       10 9 Rotoren und Rotor   Becher Lebensdauer   Exp Date   Autoklavieren                               Zubeh  r mit abweichender 11026 7 Jahre   Lebensdauer 12082 7 Jahre  12083 7 Jahre  12084 7 Jahre  12085 7 Jahre  12092 5 Jahre 20 x  12093 5 Jahre 20 x  12094 5 Jahre 20 x  12096 5 Jahre 20 x    102   bersicht       10 10 Bestandigkeitstabelle    Bestandigkeiten bei 20   C      keine Angabe                                                                                                                 1 sehr gut bestandi   am c  2 gut Ee f   S  gt   3 bedingt best  ndig   I   g Ct  4 unbest  ndig   Se E    5  lt   lt  S   S 22   89 2 E 85 2 2 535   S S   t i    e   FF b E   S s gt  5 22 5   2 2 ER E   2 rol 2g 2 2 2 2 2 EF  am
37. Seite 2 dieses Formblattes mit  was Sie zu beanstanden    haben und welche Arbeiten ausgef  hrt werden sollen     Um unser Personal zu sch  tzen  m  ssen wir sicherstellen  dass die Ger  te und Komponenten weder biologisch  noch chemisch  noch  radioaktiv kontaminiert sind  Wir k  nnen diese Ger  te oder Komponenten daher nur annehmen  wenn       die Ger  te und Komponenten ad  quat gereinigt und dekontaminiert wurden       diese Erkl  rung durch eine autorisierte Person ausgef  llt  unterzeichnet und an uns zur  ckgesandt wurde     Wir bitte Sie um Verst  ndnis f  r unsere Ma  nahmen  unseren Angestellten eine sichere und ungef  hrliche Arbeitsumgebung    bereitzustellen        A  Beschreibung der Ger  te und Komponenten          Beschreibung   Artikel Nr        Serien Nr        Rechnungs  Lieferschein Nr           Lieferdatum                B  Kontaminierung   Reinigung          Bitte beschreiben Sie pr  zise die biologische   chemische  oder  radioaktive Kontaminierung    Das Ger  t war kontaminiert mit    Bitte beschreiben Sie die Reinigungs  und  Dekontaminierungsmethode  prozedur    und wurde gereinigt und dekontaminiert durch                   Erkl  rung   ber die Dekontaminierung 111       F 13 01 Seite  2 3    Version D   sartorius    01 G  ltig ab  01 01 2008          C  Rechtsverbindliche Erkl  rung    Hiermit versichere ich wir  da   die Angaben in diesem Formular korrekt und vollst  ndig sind    Die Ger  te und Komponenten wurden entsprechend den gesetzlichen Bes
38. a brakeless manner     As a general rule  the lock can be opened more easily with the emergency lid release  system if the load on it is relieved by exerting slight pressure on the lid     Malfunctions and Error Correction 31          7 2 Table of Error Codes                                     Error no  Kind of error Measures Note  1  9 System error   Allow to slow down All these errors stop the    Power off  on centrifuge or cause it to  10 19 Speedometer error   Allow to slow down decelerate brakeless    Power off on  20 29 Motor error   Power off    Ensure ventilation  30 39 EEPROM error   Allow to slow down With error 34  35  and 36     Power off   on the centrifuge will stop   with error 37 and 38 only  an error message will be  given  40 45 Temperature error   Allow to slow down   only for refrigerated centrifuges    Power off    Allow to cool down    Provide better ventilation  only air  cooled centrifuges     Provide sufficient water throughput   only water cooled centrifuges   46 49 Imbalance error   Allow to slow down    Power off    Eliminate the imbalance  50 59 Lid error   Press lid key With error 50 and 51  the    Close lid centrifuge will stop    Remove foreign matter from the  opening of the lid lock device  60 69 Process error   Allow to slow down With error 60 message    Power off   on  power failure during run    with error 61  the  message  stop after power  on   70 79 Communication error   Allow to slow down    Power off   on  80 89 Parameter error   Pow
39. alth of persons   Non observance of these notes can cause minor injuries or damage to property                 This symbol indicates important information        The operator is responsible for authorizing only qualified personnel to work on the  centrifuge  see P chapter 3 4  Operating Personnel       The areas of responsibility of the personnel concerning the operation  maintenance  and care of the unit must be clearly defined     The safety conscious work of the personnel in compliance with the operating manual  and the relevant EC and national health and safety regulations as well as with the  accident prevention regulations must be checked at regular intervals  e g  every  month      Under the international rules for health and safety at work  the operator is obliged   to  only in Germany  Trade association rules  BGR 500  chapter 2 11 part 3        take measures in order to prevent all danger to life or health during work      ensure that centrifuges are operated properly and entirely as intended  see   gt  chapter 1 2  Intended Use          take protective measures against fire and explosion when working with hazardous  substances        take measures for the safe opening of centrifuges     Persons operating the unit must       be familiar with the fundamental regulations concerning workplace safety and  accident prevention       have read and understood this operating manual  and in particular the safety  sections and warning notes  and confirmed this with their signa
40. and specialized  personnel      Prior to any start up  check the centrifuge  rotor and accessories for signs of  damage that can be discerned from the outside  Special attention must be  paid to all of the rubber parts  e g  motor cover  lid seal  and adapters  in  terms of visible structural changes  Defective parts must be replaced  immediately      Open the centrifuge when it is not in use so that moisture can evaporate        14 Safety          3 6 3 Fire Prevention   Always use fuses with the same type and rating specified     Do not spin explosive or inflammable substances       Do not use the centrifuge within hazardous locations      gt     WARNING        3 6 4 Chemical and If pathogenic  toxic or radioactive samples are intended to be used in the centrifuge   Biological Safety it is in the responsibility of the user to ensure that all necessary safety regulations   guidelines  precautions and practices are adhered to accordingly          Infectious  toxic  pathogenic and radioactive substances may only be used in  special  certified containment systems with a bio seal in order to prevent the  material from being released      Take suitable precautions for your own safety if there is a risk of toxic   radioactive or pathogenic contamination      Materials that chemically react with each other with a high level of energy  are prohibited             Keep informed about local measures to avoid harmful emissions  depending  on the substances to be centrifuged       Protec
41. asks  The following parameters can be set         Speed selection in increments of 100 revolutions      RCF in increments of 100   g       Runtime  99 min  59 sec  in increments of 1 sec      Short run     Continuous run       Softstart   Softstop    Besides the already mentioned passive safety measures due to the solid construction   the following active preventive measures are integrated for your safety     The centrifuge can be started only when the power switch is in the  ONT position and  the lid is properly closed  After closing the lid  the lock is secured by a motor  After  the run  the lid opens automatically when the rotor is stationary  If the power fails   the lid can be opened with the emergency lid release        The lid may only be opened and unlocked when the rotor is stationary   see  gt  chapter 10 3 3 Emergency Lid Release         An internal system check monitors the data transfer and sensor signals with regard to  errors  If an error occurs  an error message is displayed indicating the error number  on the display  see   chapter 10 4 1  Table of Error Codes       With the appropriate measuring instrument  a protective conductor test can be  carried out by authorized personnel  Please contact Sartorius Service        6 4 Operating Elements    6 4 1 Control Panel    6 4 1 1 Start   Stop Key        START STOP    6 4 1 2 Select Key    rem  g  time       SELECT    6 4 1 3 Lid Key  c     OPEN                                                    Tet pe   5 run EB 
42. assplitter besch  digen die Oberfl  chen Beschichtung  z B  Eloxal  der Becher   es entsteht Korrosion      Glassplitter im Gummieinsatz der Becher verursachen weiteren Glasbruch      Glassplitter im Schwenklager der Tragbolzen verhindern ein gleichm    iges  Ausschwingen der Becher und Vielfachtrager  es entsteht Unwucht      Glassplitter in der Rotorkammer verursachen durch die starke Luftumw  lzung  einen Metallabrieb  Dieser feine Metallstaub verunreinigt nicht nur die Rotor   kammer  den Rotor sowie die Proben sehr stark  er besch  digt auch die Ober   fl  chen der Zubeh  rteile  der Rotoren und der Rotorkammer     Entfernen der feinen Glassplitter und des Metallstaubs aus der Rotorkammer        Rotorkammer im oberen Drittel dick mit Vaseline oder dergleichen einfetten        Rotor anschlie  end f  r einige Minuten bei mittlerer Drehzahl  ca  2 000 min    rotieren lassen  W  hrend dieser Prozedur werden Staub und Glasteilchen auf  der Fettschicht gebunden      Anschlie  end die Fettschicht mit Staub und Glassplittern mit einem Lappen  entfernen      Vorgang gegebenenfalls wiederholen         Handels  bliche Desinfektionsmittel  wie z  B  Sagrotan    Buraton    oder Terralin     in Apotheken oder Drogerien erh  ltlich  verwenden        Die Zentrifuge und das Zubeh  r bestehen aus unterschiedlichen Materialien   M  gliche Unvertr  glichkeiten sind zu beachten      Bevor andere als die von uns empfohlenen Reinigungs  und Desinfektionsmittel  angewendet werden  hat sich der 
43. aufzeit nicht mehr im Display angezeigt    Der Zentrifugationslauf wird jedoch fortgesetzt        Zum Beenden des Dauerbetriebs Start   Stop Taste dr  cken  Der Lauf wird  beendet        Eine konkrete Laufzeit eingeben  Der Zentrifugationslauf wird nach Ablauf  dieser Zeit beendet     6 5 5 Softstart  und Soft  Die Softstart Funktion bewirkt eine Verl  ngerung der Beschleunigungszeit   stop Funktionen die Softstop Funktion bewirkt eine Verl  ngerung der Bremszeit  Die jeweilige Kombi   nation wird im Display angezeigt       Select Taste mehrfach dr  cken  bis im linken Anzeigefeld oben das Segment     Soft stop   start  blinkt       Pfeiltasten dr  cken  bis die Anzeige  Soft stop   start on  erscheint  Softstart  und  Softstop Funktionen sind nun aktiviert     Pfeiltasten dr  cken  bis die Anzeige    Soft stop on  erscheint  Nur die Softstop   Funktion ist nun aktiviert  der Anlauf erfolgt mit normaler Geschwindigkeit     Pfeiltasten dr  cken  bis die Anzeige    Soft off  erscheint  Die Zentrifuge beschleu   nigt und bremst jetzt wieder mit normaler Geschwindigkeit     Die Daten werden sofort   bernommen und nach Ablauf von ca  20 sec gespeichert     Die Einstellungen k  nnen wie oben beschrieben auch w  hrend des Laufs ver  ndert  werden     84 Betrieb       6 5 6 Rotorauswahl    6 6 Ausschalten    In der Werkseinstellung ist der Rotor 12084 vorgew  hlt  Wird ein anderer Rotor ein   gesetzt  muss die Konfiguration angepasst werden  damit die vorgegebene maximale  Drehzahl e
44. automatisch den anderen Wert fest      Zur Eingabe eines Wertes mehrfach die Select Taste dr  cken  bis die entsprechende  Einheit in der Anzeige blinkt      Den gew  nschten Drehzahl  oder RZB Wert durch Dr  cken der Pfeiltasten  ausw  hlen      Daten durch Dr  cken der Start Taste speichern     Die Daten werden auch nach Ablauf von ca  20 sec automatisch gespeichert   wenn in dieser Zeit keine Taste gedr  ckt wurde     W  hrend des Laufs kann mit den Pfeiltasten zwischen Drehzahl  und RZB Wert  gewechselt werden     Der vorgew  hlte Drehzahl  oder RZB Wert l  sst sich w  hrend des Zentrifugenlaufs    ndern     Mehrfach die Select Taste dr  cken  bis die entsprechende Einheit in der  Anzeige blinkt     Den gew  nschten Drehzahl  oder RZB Wert durch Dr  cken der Pfeiltasten   ndern   Die Parameter werden sofort   bernommen     In der mittleren Zeile des Displays wird die vorgew  hlte Gesamtlaufzeit angezeigt    W  hrend des Zentrifugenlaufs wird die Restlaufzeit angezeigt  Die Laufzeit der   Zentrifuge lasst sich in Sekunden Intervallen bis 99 Minuten und 59 Sekunden   einstellen        Zur Eingabe einer Laufzeit mehrfach die Select Taste dr  cken  bis die  entsprechende Einheit in der Anzeige blinkt      Die gew  nschte Laufzeit durch Dr  cken der Pfeiltasten eingeben      Daten durch Dr  cken der Start Taste speichern     Die Daten werden auch nach Ablauf von ca  20 sec automatisch gespeichert   wenn in dieser Zeit keine Taste gedr  ckt wurde     Die Laufzeit lasst sich w  
45. be der Fehlernummer   ber das Display ausgegeben  siehe  gt  Kapitel 10 4 1     Fehlertabelle       6 3 6 3 Schutzleiterpr  fung Mit entsprechendem Messger  t kann eine Schutzleiterpr  fung durch autorisiertes  Fachpersonal durchgef  hrt werden  Bitte wenden Sie sich an den Sartorius Service     80 Betrieb       6 4 Bedienelemente    6 4 1 Bedienfeld    6 4 1 1 Taste Start   Stop    6 4 1 2 Taste Select    6 4 1 3 Taste Deckel          START STOP    rpm g  time       SELECT    A    OPEN                      4 O00 G              SELECT   SET   START STOP    Ge er                   1 Taste Deckel    2 Taste    Start   Stop   3 Pfeiltasten  Set   4 Taste  Select    5 Anzeige      ber das Bedienfeld wird die Zentrifuge direkt in Betrieb gesetzt     Beim Einschalten der Zentrifuge leuchten kurzzeitig alle Segmente des Displays   Die Betriebsbereitschaft ist hergestellt     Mit dieser Taste k  nnen Sie       die Zentrifuge starten      einen zuvor eingeleiteten Bremsvorgang unterbrechen und die Zentrifuge  erneut starten      in den Kurzlauf wechseln  siehe  gt  Kapitel 6 5 4 2  Kurzzeitbetrieb        den Zentrifugierlauf vorzeitig beenden     Die Zentrifuge kann starten  wenn      der Deckel geschlossen ist     Mit dieser Taste k  nnen Sie      den Editiermodus aktivieren       den zu   ndernden Parameter ausw  hlen     Mit dieser Taste k  nnen Sie      den Deckel   ffnen     Dies ist nur m  glich  wenn    die Zentrifuge noch nicht gestartet wurde     Betrieb 81       6 4 1 4 Pfei
46. bes outside of the centrifuge  Liquids in the bores of the rotor cause  corrosion      Fill the tubes carefully and arrange them according to their weight  Imbalances  result in the excessive wear of the bearings      Follow the safety instructions and hazard warnings  see   chapter 3  Safety       The new generation of laboratory centrifuges from Sartorius Stedim Biotech GmbH is  microprocessor controlled and equipped with brushless  low noise and long lasting  induction motors     The problems caused when replacing brushes is eliminated and since no carbon dust  is generated  installation in clean rooms is possible if appropriate accessories are  used     The centrifuge is installed in a solid die cast construction    The centrifuge lid is also made of sturdy die cast and is covered with plastic parts   The lid is secured from the rear by a stable bolt and from the front by the motorized  cover lock  This creates a security capsule around the rotor space     An asynchronous motor is used as the drive motor     The display consists of a hermetically sealed LCD graphic display within a membrane  keypad with a clearly distinct pressure point   Operating states are indicated     Operation 23       6 3 5 Electronics    6 3 6 Safety Devices    6 3 6 1 Lid Lock Device     Lid Clamp    6 3 6 2 System Check    6 3 6 3 Grounded    Conductor Test    24    Operation    The electronics controlled by a microprocessor allow extensive customization of the  centrifuge to a wide variety of t
47. bes that are excessively long        WARNING        Safety 15       3 6 6 Resistance of Plastics Chemical influences have a strong effect on the polymeric chains of plastics  and   therefore  on their physical properties  Plastic parts can be damaged if solvents  acids  or alkaline solutions are used        Refer to the resistance data  see  gt  chapter 10 10    Resistance Data          3 6 7 Service Life of Rotors The rotors and accessories have a limited service life   and Accessories         Perform regular checks  at least once per month  for safety reasons     Pay special attention to changes  such as corrosion  cracks  material abrasion     WARNING    Cl     After 10 years  they must be inspected by the manufacturer       After 50 000 cycles  the rotor must be scrapped for reasons of safety      If other data concerning the service life are engraved on the rotor or bucket   these data shall apply accordingly  For example  a bucket with the engraving     max  cycles   10 000    has a service life of 10 000 cycles  and a rotor with  the engraving    Exp  date 02 15  must be scrapped in February 2015 at the  latest  see figure         13850    max cycles   10 000      max load 7 DATE S      2100g S    Fig  4  Different service life   engraving on the bucket   rotor          Refer to the table of rotors and accessories with a different service life   see  gt  chapter 10 9    Table of Rotors and Accessories with a Different Service  Life               3 7 Safety Devices    3
48. briknummer angeben     Serviceanforderung direkt   ber das Internet nutzen        Wartung und Instandhaltung       8 4 R  cksendung defekter  Teile    8 5 Wartung    Trotz aller Sorgfalt bei der Fertigung unserer Produkte ist es hin und wieder  notwendig  das Ger  t oder ein Zubeh  rteil an den Hersteller zur  ckzusenden     Um eine R  cksendung von Zentrifugen  Ersatzteilen oder Zubeh  r z  gig und  wirtschaftlich bearbeiten zu k  nnen  ben  tigen wir vollst  ndige und umfassende  Angaben zum Vorgang  F  llen Sie deshalb die nachfolgend aufgef  hrten  Formulare komplett und sorgf  ltig aus und senden Sie sie zusammen mit dem  Produkt zur  ck     1  Unbedenklichkeitsbescheinigung des Betreibers  Dekontaminationserkl  rung   Als zertifiziertes Unternehmen und aufgrund gesetzlicher Vorschriften zum Schutz  unserer Mitarbeiter und der Umwelt sind wir verpflichtet  f  r alle Wareneing  nge  die Unbedenklichkeit zu dokumentieren  Zu diesem Zweck ben  tigen wir eine  Dekontaminationserkl  rung     Das Formular muss von autorisiertem Fachpersonal vollst  ndig ausgef  llt   und abgezeichnet werden     Bringen Sie das Original gut sichtbar au  en an der Verpackung an        Liegt der R  cksendung keine entsprechende Erkl  rung bei  f  hren wir eine  kostenpflichtige Dekontamination zu Ihren Lasten durch        2  Formular zur R  cksendung defekter Teile   Auf diesem Formular werden die produktbezogenen Daten eingetragen    Sie erleichtern die Zuordnung und erm  glichen eine z  gige Ab
49. centripetal force  depends on the distance between the object and the axis of  rotation as well as on the angular velocity  The bigger the radius in the rotor chamber  is and the higher the speed is  the higher the centripetal acceleration is  However  the  forces acting on the rotor also increase           2 2 2 Area of Application    2 2 2 1 Speed  Radius and  Relative Centrifugal Force    2 2 2 2 Density    Depending on the area of application of the centrifuge and also on the particle size   solids content and volume throughput of the mixture of substances that is to be  centrifuged  there are different types of centrifuges     The areas of application go from household use as a salad spinner or honey separator  up to specialized technical applications in the clinical  biological or biochemical  context         For numerous clinical examinations  cellular material must be separated from the  liquid to be analyzed  The normal separation process can be sped up considerably  by using laboratory centrifuges        n the metal working industry  centrifuges are used for separating oil from metal  cuttings  Dairies use centrifuges in order to separate cow s milk into cream and  low fat milk         Particularly big centrifuges are used in the sugar industry   They are used to separate the syrup from the crystalline sugar       Ultracentrifuges are predominantly used in biology and biochemistry in order to  isolate particles  e g  viruses  They are specifically designed for high 
50. der Deckel richtig geschlossen ist   Die elektrischen Verriegelungen m  ssen eingerastet sein  Der Deckel kann erst  ge  ffnet werden  wenn der Rotor stillsteht  Wird der Deckel   ber die Notentriegelung  w  hrend des Laufes ge  ffnet  siehe  gt  Kapitel 7 1 1   Notentriegelung    schaltet die  Zentrifuge sofort ab und l  uft frei aus  Bei ge  ffnetem Deckel ist der Antrieb vom  Netz getrennt  d h  ein Start der Zentrifuge ist nicht m  glich     72 Sicherheit       3 7 2 Systemkontrolle    3 8 Verhalten bei Gefahren  und Unfallen    3 9 Restrisiken    Eine interne Systemkontrolle   berwacht den Datenverkehr und die Sensorsignale  auf Plausibilitat  Das System f  hrt kontinuierlich eine Selbst  berwachung durch  und erkennt St  rungen  Fehlermeldungen werden mit einer Nummer im Drehzahl     RZB Display angezeigt  siehe P Kapitel 7 2    Tabelle der Fehlermeldungen          A    WARNUNG       In Notsituationen Zentrifuge sofort ausschalten     Im Zweifelsfall immer den Notarzt rufen        Die Zentrifuge ist nach dem Stand der Technik und den anerkannten sicherheits   technischen Regeln gebaut  Dennoch k  nnen bei ihrer Verwendung Gefahren  f  r Leib und Leben des Benutzers oder Dritter bzw  Beeintr  chtigungen am Ger  t  oder an anderen Sachwerten entstehen     Die Zentrifuge ist nur bestimmungsgem     zu verwenden  siehe  gt  Kapitel   1 2    Bestimmungsgem    e Verwendung       Das Ger  t darf nur in einwandfreiem Zustand betrieben werden     Alle St  rungen  die die Sicherhe
51. e  10 1 Technische Daten     10 1 1 Umgebungsbedingungen                  Formeln   mathematischer Zusammenhang      10 2 1 Relative Zentrifugal   beschleunigung  RZB                       10 2 2 Dichte  urere A Nd EE e ends  10 2 3 Drehzahl Schwerefeld Diagramm         Fehlerbehebung         seen  10 3 1 Zentrifuge l  sst sich nicht starten         10 3 2 Zentrifuge bremst w  hrend  des Laufes ab     10 2    10 3    10 4  10 4 1 Fehlertabelle                               Zubeh  r f  r CENTRISART  A 14                     Radien der Rotoren                                  Dekontaminationser   kl  rung   R  cksendeerkl  rung                       Drehzahl Schwerefeld Diagramm                  Rotoren und Zubeh  r mit abweichender  Lebensdauer 0000  c cece cece eee eee  10 10 Best  ndigkeitstabelle                                10 5  10 6  10 7    10 8  10 9    Konformitatserklarung       0 0 00  cece eee eee  NRILeZertifikat  44 200 ns AEN AR A dE     11  Stichwortverzeichnis                 ssuuuuuuusuuussss    12  Erkl  rung   ber die Dekontaminierung                       Besondere Hinweise    Diese Dokumentation zur Mikrozentrifuge CENTRISART  A 14 beschreibt das   Ger  t zu dem bei der Revisions Nr  angegebenen Zeitpunkt der Druckausgabe  Alle  Angaben wurden sorgfaltig zusammengestellt  erfolgen jedoch ohne Gewahr  Die  Sartorius Stedim Biotech GmbH beh  lt sich   nderungen in Aufbau und Ausstattung  seiner Produkte sowie der zugeh  rigen Dokumentationen vor  ohne ges
52. e eliminated immediately    3 6 2 Mechanical Safety In order to ensure the safe operation of the centrifuge  observe the following      Do not open the lid when the rotor is in motion    A   Do not reach into the rotor chamber when the rotor is in motion   WARNING    7 Do not use the centrifuge if it was installed incorrectly      Do not use the centrifuge without panels      Do not use the centrifuge if the rotors and inserts show signs of corrosion or  other defects      Only use the centrifuge with rotors and accessories that have been approved  by the manufacturer    In case of doubt  contact the manufacturer      Do not hold your fingers between the lid and the housing when closing the lid   Risk of crushing      Defective lid relieving devices could cause the centrifuge lid to fall  contact  the service department  if necessary   Risk of crushing      Do not hit or move the centrifuge during its operation      Do not lean against or rest on the centrifuge during its operation      Do not spin any substances that could damage the material of the rotors and  buckets of the centrifuge in any way  Highly corrosive substances  for  example  damage the material and affect the mechanical strength of the  rotors and buckets      Stop the centrifuge immediately in the event of a malfunction  Eliminate the   A malfunction  see  gt  chapter 7    Malfunctions and Error Correction   or inform  WARNING  Sartorius Service       Ensure that all repairs are performed only by authorized 
53. e of glass breakage  immediately remove all glass particles  e g  with a  vacuum cleaner   Replace the rubber cushions since even thorough cleaning will  not remove all glass particles          Glass particles will damage the surface coating  e g  anodising  of the buckets   which will then lead to corrosion      Glass particles in the rubber cushions of the buckets will cause glass breakage  again      Glass particles on the pivot bearing of the load bearing bolts prevent the buckets  and carriers from swinging evenly  which will cause an imbalance      Glass particles in the rotor chamber will cause metal abrasion due to the strong air  circulation  This metal dust will not only pollute the rotor chamber  rotor and  materials to be centrifuged but also damage the surfaces of the accessories  rotors  and rotor chamber     In order to completely remove the glass particles and metal dust from the rotor   chamber      Grease the upper third of the rotor chamber with e g  Vaseline        Then  let the rotor rotate for a few minutes at a moderate speed  approx  2000  min     The glass and metal particles will now collect at the greased part      Remove the grease with the glass and metal particles with a cloth         f necessary  repeat this procedure       Use commercially available disinfectants e g  Sagrotan   Buraton    or Terralin     available at chemist s shops or drug stores         The centrifuge and the accessories consist of various materials  A possible  incompatibil
54. ect key until  Softstop on  is displayed  Only the softstop function will  be active and the centrifuge will start at normal speed        Press the select key until  Soft off  is displayed  The centrifuge will now accelerate  and brake at normal speed     The data will be accepted immediately and saved after approx  20 seconds   You can also change the settings as described above during a centrifugation run        6 5 6 Rotor Selection    6 6 Switching off the System    In the delivery status of the centrifuge  the rotor 12084 is preselected  If another   rotor is installed  the configuration must be changed  so that the allowed maximum   speed of the rotor can be reached        To select another rotor  press the select key and hold it for approx  2 seconds        Choose the number of the installed rotor out of the following list  by pressing the  up   down keys           Code 1 2 3 4 5  Rotor 11026 12082 12083 12084 12085  Code 6 7 8 9 10  Rotor 12092 12093 12094 12096           Press the  select  key to confirm the input     The RCF value will be adjusted automatically to the selected rotor        The rotor selection will be saved under the corresponding program number            Open the centrifuge when it is not in use so moisture can evaporate     Switch the centrifuge off by pressing the mains power switch     Operation 29       7 1 General Malfunctions    7  Malfunctions and Error Correction    Malfunctions are indicated by error messages with a number in the speed   R
55. ements   No chemical or biological or radioisotopic risks remain that can endanger exposed persons    safety or health           Company   Institute       Address   Country       Tel    Fax  with area code        Name of the authorized person       Position       Signature   Date             Reason for return    L1 wrong delivery U exchange U repair Q modification U disposal 0 other             Please describe the problem s  or fault s  you have found  for repair  and or indicate the remedial  actions you require       56    Declaration of Decontamination          F 13 01 Page    3 3 Return of material Hai  sartorius    Version    01 Effective Date    01 01 2008    biotech          F  Reserved for Sartorius Service Center    Notes             Please pack the unit properly and send it freight paid to your  local service supplier or directly to Sartorius Stedim Biotech  GmbH       Sartorius Stedim Biotech GmbH  Servicezentrum Biotechnologie  August Spindler Stra  e 11  37079 Goettingen  Germany  Telephone  49 551 308 1300  Telefax  49 551 308 1293          Declaration of Decontamination    57       58       Inhalt    Besondere Hinweis    61   1  Allgemeine Informationen    63   1 1 Stellenwert der Betriebsanleitung                    63   1 2 Bestimmungsgem    e Verwendung                   63   1 3 Gew  hrleistung und Haftung    63   1 4 Lieferumfang  0 060  c cece ee 63   2  Aufbau und Wirkungsweise                          055 65   2 1 Aufbau der Zentrifuge eee eee eee ee 65
56. enen LCD Grafik Display  innerhalb einer Folientastatur mit deutlich ausgepr  gtem Druckpunkt   Betriebszust  nde werden angezeigt     Betrieb 79       6 3 5 Elektronik Die von einem Mikroprozessor kontrollierte Elektronik erlaubt umfangreiche  Anpassungsm  glichkeiten der Zentrifuge an die unterschiedlichsten Aufgaben   stellungen  Folgende Parameter sind einstellbar     l    Drehzahlvorwahl in Schritten von 100 Umdrehungen      RZB in Schritten von 100 x g   Zeitbetrieb  99 min  59 sec  in Schritten von 1 sec  Kurzzeitbetrieb   Dauerbetrieb   Softstart   Softstop    l    l    l    l    6 3 6 Sicherheitsein  Neben den bereits erw  hnten passiven Sicherheitseinrichtungen durch die solide  richtungen Konstruktion gibt es noch nachstehende aktive Vorsorge f  r Ihre Sicherheit    6 3 6 1 Deckelverriegelung  Die Zentrifuge kann nur gestartet werden  wenn der Netzschalter auf  EIN  steht  Deckelzuhaltung und der Deckel richtig geschlossen ist  Nach Schlie  en des Deckels wird das Schloss    motorisch verriegelt  Der Deckel   ffnet nach dem Lauf automatisch  wenn der Rotor  stillsteht  Uber die Notentriegelung kann der Deckel bei Netzausfall ge  ffnet werden        Der Deckel darf nur bei stehendem Rotor entriegelt und ge  ffnet werden   siehe  gt  Kapitel 10 3 3 Notentriegelung des Deckels         6 3 6 2 Systemkontrolle Eine interne Systemkontrolle   berwacht den Datenverkehr und die Sensorsignale  auf Fehlerfreiheit  Bei Auftreten einer St  rung wird eine Fehlermeldung mit  Anga
57. entriegelung    1 Flasche Korrosionsschutz  l  Ersatzsicherung    Allgemeine Informationen 63       Zubeh  r gem     Ihrer Bestellung  unserer Auftragsbestatigung und unserem  Lieferschein     Rotorbestell Nr  Rotor Nr    64 Allgemeine Informationen       2 1 Aufbau der Zentrifuge    2 1 1 Funktions   und Bedienelemente    2  Aufbau und Wirkungsweise             den  lt                      Abb  1  Gesamtansicht der Zentrifuge    1 Deckel  2 Display  3 Bedienfeld  siehe   Kapitel 6 4 1  Bedienfeld            una       o  zZ EB       4 6 5          Abb  2  R  ckansicht der Zentrifuge  4 Typenschild  siehe  gt  Kapitel 2 1 2    Typenschild        5 Netzschalter  6 Netzeingang    Aufbau und Wirkungsweise 65          2 1 2 Typenschild    2 2 Wirkungsweise    2 2 1 Prinzip der  Zentrifugation    66    Aufbau und Wirkungsweise                   Abb  3  Beispiel eines Typenschildes    1 Typenbezeichnung   2 Fabriknummer   3 Max  Drehzahl   4 Max  kinetische Energie   5 Max  zul  ssige Dichte   6 Nennspannung   7 Eingangssicherung   8 Symbol f  r gesonderte Entsorgung  siehe   Kapitel 9  Entsorgung    9 CE Zeichen gem     Richtlinie 2006 42 EG  10 Bestellnummer   11 Baujahr   12 Leistungsaufnahme    Die Zentrifugation ist ein Verfahren zur Trennung von heterogenen Stoffgemischen   Suspensionen  Emulsionen oder Gasgemischen  in seine Komponenten  Das Stoffge   misch  das auf einer Kreisbahn rotiert  wird hierbei der Zentripetalbeschleunigung  ausgesetzt  die um ein Vielfaches gr  Ber 
58. er off With error 83  error    Allow to cool down message only    Provide for better ventilation  90 99 Other errors   Provide sufficient water throughput Check connections     only water cooled centrifuges        If it is impossible to eliminate the errors  contact Sartorius Service        32 Malfunctions and Error Correction       8 1 Maintenance    8 1 1 Centrifuge    8 1 2 Accessories    8  Maintenance and Service    The centrifuge  rotor and accessories are subject to high mechanical stress  Thorough  maintenance performed by the user extends the service life and prevents premature  failure        A    CAUTION     If corrosion or other damage occurs due to improper care  the manufacturer  cannot be held liable or subject to any warranty claims            Use soap water or other water soluble  mild cleaning agents with a pH value  between 6 and 8 for cleaning the centrifuge and accessories        Avoid corrosive and aggressive substances      Do not use solvents      Do not use agents with abrasive particles      Do not expose the centrifuge and rotors to intensive UV radiation or thermal  stress  e g  by heat generators        Unplug the mains power plug before cleaning        Carefully remove all liquids  including water and particularly all the solvents  acids  and alkaline solutions from the rotor chamber using a cloth in order to avoid  damage to the motor bearings      If the centrifuge has been contaminated with toxic  radioactive or pathogenic  substances  clean t
59. eraturfehler   gilt nur f  r K  hlzentrifugen       auslaufen lassen     Netz aus     abk  hlen lassen     f  r bessere Bel  ftung sorgen     bei luftgek  hlten Zentrifugen     auf ausreichenden Wasserdurchfluss    achten  bei wassergek  hlten  Zentrifugen        46 49    Unwuchtfehler      auslaufen lassen    Netz aus    Unwucht beseitigen       50 59    Deckelfehler      Deckeltaste dr  cken    Deckel schlieBen      Fremdk  rper aus der Kloben  ffnung    entfernen    Bei Fehler 50 und 51  stoppt Zentrifuge       60 69    Prozessfehler      auslaufen lassen    Netz aus   ein    60    Stromausfall w  hrend  des Laufs    61  Stop nach Netz ein        70 79    Kommunikationsfehler      auslaufen lassen    Netz aus   ein       80 89    Parameterfehler      Netz aus    abk  hlen lassen    f  r bessere Bel  ftung sorgen    Bei Fehler 83 nur Meldung       90 99    88    sonstige Fehler      auf ausreichenden Wasserdurchfluss  achten  bei wassergek  hlten Zentri     fugen     Verbindungen   berpr  fen       Sollten sich die Fehler nicht beheben lassen  Service verstandigen        St  rungen und Fehlersuche       8 1 Wartungsarbeiten    8 1 1 Zentrifuge    8 1 2 Zubeh  r    8  Wartung und Instandhaltung    Zentrifuge  Rotor und Zubeh  r sind hohen mechanischen Belastungen ausgesetzt   Eine sorgf  ltige Pflege durch den Benutzer verl  ngert die Lebensdauer und  verhindert den vorzeitigen Ausfall        A    VORSICHT     Kommt es wegen mangelnder Pflege zu Korrosionsbildung oder  Folge
60. escribed in this manual  This manual  may also contain information that does not apply to your device  Please notify us  if any information is missing that is important to you  if you find any errors in the  content or require more extensive information on specific components     The micro centrifuge CENTRISART  A 14 is just one product from the line of  laboratory equipment offered by Sartorius Stedim Biotech GmbH    The rest of the product line includes shakers and shaker incubators  homogenizers   centrifuges  ultrapure water systems  air samplers and fermenters   bioreactors   For more information  please visit our website www sartorius stedim com    On request  we would be delighted to inform you about our entire product range     Sartorius Stedim Biotech GmbH  August Spindler Strasse 11  D 37079 G  ttingen  info sartorius stedim com  www sartorius stedim com    Special Notes       1 1 Importance of the  Operating Manual    1 2 Intended Use    1 3 Warranty and Liability    1 4 Equipment Supplied    1  General Information    To ensure the safe and trouble free operation of the device  the operator must be  familiar with the fundamental safety precautions and hazard warnings     The operating manual includes important information concerning the safe operation  of the centrifuge     This operating manual and  in particular  the notes on safety and hazards must be  observed by all persons operating the centrifuge     In addition  the local rules and regulations for the preve
61. esistant E    ZS        m  4 not resistant    ey      S         S  B SS u SS a 5  9 5 g  E  gt  xs   2 c  gt   gt  E 5  s es     8 SS SS SS E  z s gt  S     S  E 2 2 2 B E  O Ec c dd            X                 Medium Formula  9o  HDPE PA PC POM PP PSU PVC PVC PIFE AL  Wax     100   1 1   1     1 1  Wines     100 1 1 1 2 1 1 1 1 4  Xylene Cl 100 3 1 4 1 4 4 4 4 1       50 Overview             eec  22008   ILER                o    Konformit  tserkl  rung   73 23 EWG  89 336 EWG  98 37 EWG     Declaration de conformite   73 23 CEE  89 336 CEE  98 37 CEE     Firma   Company   Firme    sartorius    biotech    Statement of Conformity     73 23 CEE  89 336 CEE  98 37 CEE     Sartorius Stedim Biotech GmbH       Sitz   Address   Adresse    August Spindler Strasse 11  37079 Goettingen  Germany  Phone  49 551 308 0  Fax  49 551 308 32 89  www sartorius stedim com       Die nachfolgend bezeichnete Maschine wurde  in   bereinstimmung mit den Richtlinien 73 23 EWG   89 336 EWG und 98 37 EWG hergestellt und gepr  ft     The following machine is manufactured and tested  in compliance with directions 73 23 CEE  89 336 CEE  and 98 37 CEE     La machine d  sign  e ci dessous est produit  et examin   conforme aux directives 73 23 CEE   89 336 CEE et 98 37 CEE       Bezeichnung der Maschine  Machine  D  signation de la machine    Laborzentrifuge  Laboratory Centrifuge  Centrifugeuse de laboratoire       Maschinentyp   Type   Type de la machine    Centrisart A 14             Bestell Nr  8581401 
62. ethylsulfoxid C H SO 100 1 2 4 1 1 4 4   1 1   DMSO   Dioxan C H 0  100 2 1 4 1 3 2 3 4 1 1    Ubersicht    103       Bestandigkeiten bei 20   C      keine Angabe                                                                                                                   1 sehr gut bestandi ke K s  2 gut best  ndig i        3 bedingt best  ndig S o g g Cc  4 unbest  ndig E E   5   5    E S i    o o  gt  E 9 9     i g2 2   5 f   E P P  z   5 E E D     z 52 22 2 2 2 2 E E   S r  o 2 2  amp     2 2 2     amp   Medium Formel  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL  Eisen  II  chlorid FeCl  ges  ttigt 1 3 1 3 1 1 1 1 1 4  Essigs  ure C H 0  10 1 4 1 1 1 1 1 1 1 1  Essigs  ure C H 0  90 1 4 4 4 1 3 1 4 1 1  Essigs  uremethylester CHetl  100 1 1 4 2 1   4 4 1 1  Ethanol C H O 96 1 1 1 1 1 1 1 3 1 1  Ethylacetat CHA   100 1 1 4 1 1 4 4 4 1 1  Ethylenchlorid C H Cl  100 3 3 4 1 3 4 4 4 1 1  Ethylendiamin CHN  100 1 1 3 1 1   3 4 1 1  Ethylether C H  0 100 3 1 4 1 4 4 4 4 1 1  Formaldehydl  sung CH 0 30 1 3 1 1 1       1 1  Furfurol C H 0  100 1 3 3 2 4       1 1  Glycerin C H40  100 1 1 3 1 1 1 1 2 1 1  Harnstoff CH N 0 10 1 1 1 1 1       1 1  Heptan  n  CH  100 2 1 1 1 2 1 2 4 1 1  Hexan  n  CH  100 2 1 2 1 2 1 2 4 1 1  Isopropanol C H40 100 1 1 1 1 1 1 1 4 1 2  Jodtinktur l 1 4 3 1 1   4 4 1 1  Kaliumhydrogen  CHKO  ges  ttigt 1 1 2 1 1       1 4  carbonat  Kaliumhydroxid KOH 30 1 1 4 3 1 1 1 1 1 4  Kaliumhydroxid KOH 50 1 1 4 3 1 1 1 1 1 4  Kaliumnitrat KNO  10 1 1 1 1 1   
63. ettingen  Germany  Typenbezeichnung CENTRISART  A 14       Elektr  Anschluss   Schutzklasse     Siehe Typenschild          IP Code  gem  DIN EN 60529  20  Anschlussleistung  kVA  0 157  Leistungsaufnahme  kW  0 095    Max  Stromaufnahme  A     0 68  bei 220   240 V  50   60 Hz  oder  1 5  bei 100   120 V  50  60 Hz        Leistungsdaten   Max  Drehzahl  min    Min  Drehzahl  min     Max  Kapazitat  ml   Max  Schwerefeld  x g   Min  Schwerefeld  x g   Max  kin  Energie  Nm     14 800  200   48  16 163  2   1 721       Sonstige Einstellparameter  Zeitbereich    10   99 min 59 sec  Kurzlauf  Dauerlauf          Phys  Daten   Tiefe  mm  266  Breite  mm  212  Hohe  mm  176  Gewicht  kg  6 0  Funkentst  rt gem  EN 61326 Klasse B  Ger  uschpegel  dBA   lt  60  Pr  fpflicht nein      Die Daten gelten f  r eine Umgebungstemperatur von  23  C  2  C und    Nennspannung   10         Bei einer Nennspannung von 100 V oder 200 V gelten Toleranzen von     10    5           Verwendung nur in Innenr  umen         Zul  ssige Umgebungstemperatur  5  C bis   40  C       Max  relative Luftfeuchte 80  bis 31  C  linear abnehmend auf 50  relativer    Luftfeuchte bei 40  C         Maximale H  he 2 000 m   ber NN       bersicht 95       10 2 Formeln   mathe   matischer Zusammenhang    10 2 1 Relative Zentrifugal   beschleunigung  RZB     10 2 2 Dichte    10 2 3 Drehzahl Schwerefeld  Diagramm    10 3 Fehlerbehebung    96   bersicht    Die Parameter Drehzahl  RZB und die Gruppe Rotor und Radius k  nnen n
64. ft   Date   Signature   Date   Signature 03 09 2007          Fabr  Nr    Serial No    Num  ro de fabrique    R  Vogt   Managing Director          Konformit  tserkl  rung 107          UCB   01 08    CERTIFICADO   CERTIFICAT    LL  r  cc  e  LL      EC  LU  GA  LJ  r    t  x  Lu   gt   o     2  N          CERTIFICATE ke    No  U8 12 05 75349 005    Holder of Certificate  Sartorius Stedim Biotech GmbH  August Spindler Str  11          37079 G  ttingen  GERMANY  Production 12211  Facility ies    Certification Mark   Product  Laboratory Centrifuges  Model s   Centrisart A 14  Parameters  Rated voltage  100 120V AC 220 240V AC  Raled frequency  50   60 Hz 50   60 Hz  Raled power  95W  Protection class  I  Degree of protection  IP 20  Max  speed  14800 rpm  Depth  266 mm  Width  212 mm  Height  176 mm  Weight  6 kg  Tested UL 61010 1 2004    according to  IEC 61010 2 020 2006      CANICSA C22 2 No 61010 1 2004  CANICSA C22 2 No  61010 2 020 2009    The product was voluntarily tested according to the relevant safety requirements noted above  It  can be marked with the certification mark above  The mark must not be altered in anyway  This  product certification system operated by TUV SUD America Inc  most closely resembles system  3 as defined in ISO IEC Guide 67  Certification is based on the TUV SUD  Testing and  Certification Regulations        Test report no   028 713000202 000    Date  2012 05 10       Page 1 of 1    T  V S  D AMERICA INC    10 Centennial Drive e Peabody MA 01960
65. gent  depending on the type of contamination   Take suitable precautions for  your own safety if there is a risk of toxic  radioactive or pathogenic  contamination        Dry the accessories with a soft cloth or in a drying chamber at approx  50  C     The chemical resistance of plastic decreases with rising temperatures  see   chapter   10 10    Resistance Data           f solvents  acids or alkaline solutions have been used  clean the plastic accessories  thoroughly     The rotors are produced with the highest precision  in order to withstand the  permanent high stress from high gravitational fields     Chemical reactions as well as stress corrosion  combination of oscillating pressure  and chemical reaction  can affect or destroy the metals  Barely detectable cracks on  the surface can expand and weaken the material without any visible signs       Check the material regularly  at least once a month  for    cracks  visible damage of the surface  pressure marks  signs of corrosion    other changes       Check the bores of the rotors and multiple carriers       Replace any damaged components immediately for your own safety         Remove the microhaematrocrit rotor for cleaning        Wipe the centrifuge chamber clean        Replace the rubber ring in the event of wear or glass breakage   part no 16002 for rotor 11026         8 1 5 Glass Breakage    8 2 Sterilization and  Disinfection of the Rotor  Chamber and Accessories    8 2 1 Autoclaving       A    CAUTION     In the cas
66. gerecht zu betreiben     Diese Betriebsanleitung  insbesondere die Sicherheits  und Gefahrenhinweise   sind von allen Personen zu beachten  die mit diesem Ger  t arbeiten     Dar  ber hinaus sind die f  r den Einsatzort geltenden Regeln und Vorschriften  zur Unfallverh  tung zu beachten     Zentrifugen sind kraftbetriebene Arbeitsmaschinen  in denen durch Zentrifugalkraft  Fl  ssigkeiten von festen Stoffen  Fl  ssigkeitsgemische oder Feststoffgemische  getrennt werden und somit auch nur f  r diesen Verwendungszweck bestimmt sind   Eine andere oder dar  ber hinausgehende Benutzung gilt als nicht bestimmungsge   m      F  r hieraus entstehende Sch  den haftet die Sartorius Stedim Biotech GmbH  nicht     Zur bestimmungsgem    en Verwendung geh  rt auch      das Beachten aller Hinweise aus der Betriebsanleitung und    die Einhaltung der Pflege   Reinigungs  und Instandhaltungsvorschriften     Es gelten unsere    Allgemeinen Gesch  ftsbedingungen   die dem Betreiber  seit Vertragsabschluss zur Verf  gung stehen     Gew  hrleistungs  und Haftungsanspr  che sind ausgeschlossen  wenn sie auf eine  oder mehrere der folgenden Ursachen zur  ckzuf  hren sind      nicht bestimmungsgem    en Gebrauch      Nichtbeachten der Sicherheits  und Gefahrenhinweise in der Betriebsanleitung     unsachgem    es Inbetriebnehmen  Bedienen und Warten der Zentrifuge     Zur Zentrifuge geh  ren        Anschlusskabel  Bestell Nr  269010      Rotorbefestigungsmutter  Bestell Nr  80301   Steckschl  ssel  Not
67. ges  spare parts and accessories     Please understand that we can start working only if we have received the  declarations      We recommend that you copy these pages more than once     Declaration of Decontamination   Return Form cf  Appendix     10 8 Speed Gravitational Field Diagram       13 d  dH    iz    EHI e             i af pi    SE A Fr             Wm I    7          AN A NNNM    NN  NN       gir    WANN          z  z       ri  E  FE     e     z  A       AA WANAA WWNAAAAAAA NIX    NA UN MANN ath  CAMILA AAA A AAT    KA    Wi   Win  Nr ug   HURT  RI ir  UU TIT ANS ug gaer    Wat CS ail    WILE  NN  an   H       HI  I iiiar    jil ilf s   CU ZC at  SE  IF      LZ i a    La    HIT UDO UL  aa HEEL HE ILLU M    BH EE ALIAE PELA UN 0M       E BET Diagramm in  pgkeit vom Radius der Rotoren    Ir field diagram  EZ on the radius of the A              Overview 45       10 9 Rotors and Accessories Rotor   Bucket Service Life   Exp Date   Autoclaving                               with a Different Service Life 11 026 7 years  12 082 7 years  12 083 7 years  12 084 7 years  12 085 7 years  12 092 5 years 20x  12 093 5 years 20x  12 094 5 years 20x  12 096 5 years 20x    46 Overview       10 10 Resistance Data    The data refer to resistance at 20  C                                                                                                                   no data T x    1 resistant S E 5  2 practically resistant u g g    3 partially resistant     ET 7 E E Y  4 not resistant
68. he rotor chamber immediately with a suitable decontamination  agent  depending on the type of contamination         A    WARNING     Take suitable precautions for your own safety if there is a risk of toxic   radioactive or pathogenic contamination          Lightly grease the motor shaft supporting bolt grease after cleaning and spread  the grease into a very thin layer with a cloth        A    CAUTION     For the care of the accessories  special safety measures must be considered as  these are measures that will ensure operational safety at the same time          Immediately rinse off the rotor  buckets or accessories under running water if they  have come into contact with any liquids that may cause corrosion  Use a brush for  test tubes in order to clean the bores of angle rotors  Turn the rotor upside down  and allow it to dry completely        Clean the accessories outside the centrifuge once a week or preferably after each  use  Adapters should be removed  cleaned and dried     Maintenance and Service 33          A    CAUTION     Do not clean the accessories in a dishwasher   Cleaning in a dishwasher removes the anodised coating  the result is cracking in  areas that are subject to stress        8 1 2 1 Plastic Accessories    8 1 3 Rotors    8 1 4 Microhaematocrit    Rotor    34    Maintenance and Service         f the rotors or accessories have been contaminated with toxic  radioactive or  pathogenic substances  clean them immediately with a suitable decontamination  a
69. he sealed end against  the rubber ring  Ensure that the capillary tubes fit tightly against the rubber ring   The opposite places must be loaded        Put the rotor cover on and lock it        Close the centrifuge lid        Enter the following parameters  speed 13000 min   gravitational field RCF max   11903 x g  time approx  5 min      Start the centrifuge        The centrifuge lid opens automatically when the rotor has stopped        Unlock the rotor cover and lift it off     Evaluation       Put the reader onto the rotor        Turn the reader and perform a fine adjustment with the aid of the central  eccentric mechanism in order to localize the O point and the maximum liquid  point in the capillary tubes  You can now read the percentage value        Remove the capillary tubes  Some of the tubes can also be evaluated with the  reader outside of the rotor  see the instructions for use on the back of the reader          Only use tubes that are suitable for the rotor  see P chapter 11 1  Range of  Accessories          Always load the opposite inserts of the rotors with the same accessories and fill to  avoid imbalance        6 2 2 4 Tubes    6 3 Centrifuge Description    6 3 1 Overview    6 3 2 Setup and Constructive  Safety Practices    6 3 3 Drive    6 3 4 Operation and Display    Centrifugation with Low Capacity  The tubes must be installed symmetrically so that the rotor is loaded evenly                    Fig  9  Permissible loading of an angle rotor        Load the tu
70. hrend des Zentrifugenlaufs andern      Mehrfach die Select Taste dr  cken  bis die entsprechende Einheit in der  Anzeige blinkt      Die gew  nschte Laufzeit durch Dr  cken der Pfeiltasten   ndern  Die Parameter  werden sofort   bernommen        Wenn w  hrend der Zentrifugation die Laufzeit ge  ndert wird  l  uft die  Zentrifuge die gesamte neu eingegebene Zeit hindurch  ohne die bisher abge   laufene Laufzeit zu ber  cksichtigen        Betrieb 83       6 5 4 2 Kurzzeitbetrieb Wahrend des Kurzzeitbetriebs beschleunigt die Zentrifuge mit maximaler Leistung  bis zur maximalen Drehzahl       Die Start   Stop Taste f  r die Dauer des Kurzlaufs gedr  ckt halten     Im Display erscheint die Anzeige    short run   und f  r die Dauer des Kurzlaufs wird  die Zeit in Sekunden aufw  rts gez  hlt  Nach dem Loslassen der Start   Stop Taste  bremst die Zentrifuge mit maximaler Leistung bis zum Stillstand ab     Nach Beendigung des Kurzlaufs entriegelt der Deckel automatisch  und die vorher  eingestellten Parameter werden wieder angezeigt     6 5 4 3 Dauerbetrieb Beim Dauerbetrieb ist die Laufzeit der Zentrifuge unbegrenzt und muss manuell  abgebrochen werden  Die Zentrifuge beschleunigt w  hrend des Dauerbetriebs bis zur  eingestellten Drehzahl       Zum Aktivieren des Dauerbetriebs die Select Taste dr  cken  bis die Zeiteinheit  in der Anzeige blinkt       Pfeiltaste unten dr  cken  bis die Anzeige im Display von    OO  10  auf            wechselt     Nach 99 min 59 sec wird die weitere L
71. hwerpunkt des Ger  tes  noch   ber der Tischplatte befindet  Ggf  muss das Ger  t durch eine zweite Person  gesichert werden      Den Notentriegelungsschl  ssel in die Bohrung  siehe Abbildung  Pos  1   einf  hren und auf die Achse des Deckelschlossmotors aufstecken        Die Achse mit Hilfe des Schl  ssels vorsichtig im Uhrzeigersinn drehen  bis der  Deckel   ffnet      Notentriegelungsschl  ssel abziehen und Zentrifuge wieder aufstellen        1    Abb  12    ffnung f  r die Notentriegelung an der Unterseite der Zentrifuge          A    WARNUNG     Den Deckel nur entriegeln  wenn der Rotor sich nicht dreht und jede  Gef  hrdung anderer Personen ausgeschlossen ist        Wird der Deckel   ber die Notentriegelung w  hrend des Laufes ge  ffnet  schaltet die  Zentrifuge sofort ab und l  uft frei aus     Grunds  tzlich l  sst sich das Schloss leichter per Notentriegelung   ffnen  wenn es  durch leichten Druck auf den Deckel entlastet wird     St  rungen und Fehlersuche 87          7 2 Tabelle der Fehlermeldungen    Fehlernummer    Fehlerart    Ma  nahmen    Bemerkung       1  9    Systemfehler      auslaufen lassen    Netz aus   ein       10 19    Tachofehler      auslaufen lassen    Netz aus   ein       20 29    Motorfehler      Netz aus    Bel  ftung sicherstellen    Bei allen Fehlern stoppt  die Zentrifuge oder l  uft  frei aus       30 39    Fehler im EEPROM      auslaufen lassen    Netz aus   ein    Bei Fehler 34  35  36 Stop   bei Fehler 37  38 Meldung       40 45    Temp
72. icht  unabh  ngig voneinander vorgegeben werden  Sie sind verkn  pft   ber die Formel     RZB   11 18 x 10   x r x n     Bei Eingabe von zwei Werten ist der dritte   ber die angegebene Gleichung festgelegt   Wird danach die Drehzahl oder der Schleuderradius ver  ndert  wird die daraus  resultierende RZB neu errechnet  Wird die RZB ge  ndert  wird die Drehzahl unter  Verwendung des Radius entsprechend angepasst     r   Radius in cm  n   Drehzahl in min   RZB einheitenlos    Ist die Dichte der zu zentrifugierenden Fl  ssigkeit gr    er als 1 2 g cm   verringert  sich die maximal zul  ssige Drehzahl der Zentrifuge nach folgender Formel            N   naas X4  2  Rho    A    Rho   Dichte in g cm     Als zusatzliche Hilfe dient das beiliegende Drehzahl Schwerefeld Diagramm   siehe  gt  Kapitel 10 8 Drehzahl Schwerefeld Diagramm      Die meisten Fehler lassen sich durch Aus    Einschalten beheben  Bei einem kurzen  Netzausfall w  hrend des Laufes wird dieser unterbrochen und kann durch   ffnen des  Deckels und Dr  cken der    Start   Stop  Taste wieder gestartet werden                    Keine Anzeige auf dem Display MaBnahmen   Spannung in der Steckdose  Netzsicherung   berpr  fen   Netzstecker steckt und Spannung vorhanden  Netzstecker fest einstecken   Netzschalter eingeschaltet  Netzschalter ein    Deckel geschlossen  Deckel schlieBen        10 3 1 Zentrifuge l  sst sich  nicht starten    10 3 2 Zentrifuge bremst  w  hrend des Laufes ab    10 3 3 Notentriegelung des  Deckels   
73. ie Verpackung besteht aus umweltfreundlichen Materialien  die als Sekundar   rohstoffe dienen k  nnen  Wird die Verpackung nicht mehr ben  tigt  kann diese in  Deutschland unentgeltlich   ber das Duale System der VfW entsorgt werden   Vertragsnummer D 59101 2009 1129   Anderenfalls f  hren Sie das Material nach  den geltenden Vorschriften der   rtlichen Abfallentsorgung zu  Das Ger  t inklusive  Zubeh  r und Batterien geh  rt nicht in den Hausm  ll  sondern sind vielmehr als  elektrische und elektronische Ger  te wiederzuverwerten  Hinsichtlich der Entsorgung  und Wiederverwertung wenden Sie sich bitte an unsere Service Mitarbeiter vor Ort   Dar  ber hinaus gelten die auf folgender Website aufgef  hrten Partner innerhalb   der EU     1  http   www sartorius com w  hlen    2  In der Titelleiste  Service  antippen    3  Danach  Entsorgungshinweise  w  hlen    4  Die Adressen der lokalen Sartorius Ansprechpartner zur Entsorgung finden  Sie in den angeh  ngten pdf Dateien dieser Internetseite        Mit gef  hrlichen Stoffen kontaminierte Ger  te  ABC Kontamination  werden  weder zur Reparatur noch zur Entsorgung zur  ckgenommen        Ausf  hrliche Informationen mit Service Adressen zur Reparaturannahme oder  Entsorgung Ihres Ger  tes k  nnen Sie auf unserer Internetseite  www sartorius com   finden oder   ber den Sartorius Service anfordern        10 1 Technische Daten    10 1 1 Umgebungs   bedingungen    10  Ubersicht          Hersteller Sartorius Stedim Biotech GmbH  37079 Go
74. inkelrotoren  Polykarbonatgef    e 115 118 30 40 20  Polypropylen Co Polymergef    e 115 121 30 40 20  Polypropylen Rechteckgestelle 115 118 30 40    Polypropylen Rundgestelle 115 118 30 40    Polysulfondeckel f  r Winkelrotoren 134 138 3 5 100  Polysulfonkappen f  r Becher 134 138 3 5 100  PTFE Gef    e 134 138 3 5 100  Polypropylen Ersatzgewichte f  r 115 118 30 40 k A   Blutbeutelsysteme  Edelstahl Tariergewichte f  r 121 30 30 k A     Blutbeutelsysteme       A    WARNUNG     Bei Instandhaltungsarbeiten  die die Entfernung der Verkleidung erfordern   besteht die Gefahr eines elektrischen Schlags oder mechanischer Verletzungen   Solche Arbeiten sind ausschlieBlich qualifiziertem Fachpersonal vorbehalten        Die Zentrifuge ist hohen mechanischen Belastungen ausgesetzt  Um der starken  Beanspruchung standzuhalten  werden bei der Fertigung hochwertige Bauteile  eingesetzt  Trotzdem kann es zu VerschleiBerscheinungen kommen  die von auBen  nicht sichtbar sind  Besonders Gummiteile  die u a  Bestandteil der Motoraufhangung  sind  unterliegen einem Alterungsprozess     Wir empfehlen daher  die Zentrifuge im Rahmen einer Inspektion durch den  Hersteller einmal jahrlich im Betriebszustand und im Dreijahresrhythmus im zerlegten  Zustand pr  fen zu lassen  Gummiteile sollten nach drei Jahren ausgetauscht werden     Diese Dienstleistung kann auch im Rahmen eines Wartungsvertrages  vereinbart werden          Bei Inanspruchnahme des Kundendienstes stets den Zentrifugentyp  und die Fa
75. issbildung  Rotoraufnahme  Rotorbefestigungsmutter  Rotordeckel    100    76  95    78   75   107  71 89 ff   79  89  91  63   81 95  80  81  84    74   82   72  89  91  102  66  95   66  95   89   95   75    72  100  89  76 ff     66  95   65  76  80  82  85 ff   86  96   70  86 ff     67  78  80 ff     88   73   90   77   63  76   78  76  78    Stichwortverzeichnis 109       S  uren   Schutzklasse  Schutzkleidung  Schutzleiteranschluss  Schutzleiterpr  fung  Schwerefeld    Sicherheits  und Gefahrenhinweise  Sicherheitsabstand  Sicherheitseinrichtungen  Sicherheitshinweise  Sicherheitshinweise zur Zentrifugation  Sicherheitsverschluss   Soft Stop   Soft Start   Sterilisation   St  rung   Stromaufnahme   Substanzen  leicht brennbar  radioaktiv   Systemkontrolle    Technische Daten  Transportsicherung    Umgebungstemperatur  Unfallverh  tung  Unwucht    Versorgungsspannung    Wartung  Winkelrotor    Zentrifugen  Zentrifugalbeschleunigung  relative     110 Stichwortverzeichnis    72 89   75  95   71   68   80   67  78  82  95  96   99  100   63  69  77  78  79  70  75   76  78   70 ff    71   76 77   84   91   70  80   95   70  71  89  91   73  80    95  74    95   63  69   71  78  79  88  91  75    89 ff   76  99    66   69  88  67  83       F 13 01 Seite  1 3  Version  01 G  ltig ab  01 01 2008    sartorius       Erkl  rung   ber die Dekontaminierung und  Reinigung von Ger  ten und Komponenten    Sofern Sie die Ger  te oder Komponenten zur  cksenden  teilen Sie uns bitte auf 
76. ist als die Erdbeschleunigung     Zentrifugen nutzen die Massentragheit in der Rotorkammer zur Stofftrennung   Partikel oder Medien mit h  herer Dichte wandern aufgrund der h  heren Tragheit  nach auBen  dabei verdr  ngen sie die Bestandteile mit niedrigerer Dichte  die  hierdurch zur Mitte gelangen     Die Zentripetalbeschleunigung eines K  rpers in einer Zentrifuge als Wirkung der  Zentripetalkraft ist vom Abstand des K  rpers von der Drehachse und von der Winkel   geschwindigkeit abhangig  sie steigt linear mit dem Abstand von der Drehachse und  quadratisch mit der Winkelgeschwindigkeit  Je gr    er der Radius der Rotorkammer  und je h  her die Drehzahl  desto gr    er ist die Zentripetalbeschleunigung  Allerdings  vergr    ern sich auch die auf den Rotor wirkenden Kr  fte        2 2 2 Anwendungsbereich    2 2 2 1 Drehzahl   Radius  Relative Zentrifugal   beschleunigung    2 2 2 2 Dichte    Je nach Anwendungsbereich der Zentrifuge und abh  ngig von der Teilchengr    e   dem Feststoffgehalt und dem Volumendurchsatz des zu zentrifugierenden Stoff   gemisches gibt es unterschiedliche Bauarten     Das Spektrum der Anwendungsbereiche erstreckt sich vom Einsatz im Haushalt als  Salatschleuder oder Honigschleuder bis hin zu speziellen technischen Anwendungen  im klinischen und biologischen bzw  biochemischen Bereich       F  r viele klinisch chemische Untersuchungen muss zellul  res Material von der  zu untersuchenden Fl  ssigkeit abgetrennt werden  Der normale Sedimentations   v
77. it beeintr  chtigen  sind sofort zu beseitigen     Sicherheit    73       4 1 Abmessungen und    Gewicht    4 2 Lagerbedingungen    4 3 Transporthinweise    4  Lagerung und Transport    CENTRISART  A 14                   H  he 176 mm  H  he bei ge  ffnetem Deckel 310 mm  Breite 212 mm  Tiefe 266 mm  Gewicht 6 kg    Die Zentrifuge kann in der Originalverpackung bedenkenlos bis zu einem Jahr   gelagert werden      Zentrifuge nur in trockenen R  umen lagern      Die Lagertemperatur darf  20  C nicht unterschreiten        Bei Einlagerung von mehr als einem Jahr    berseetransporten usw  unbedingt  R  cksprache mit dem Hersteller halten       Die Zentrifuge hat keine Transportsicherung     Beim Heben der Zentrifuge seitlich ansetzen        VORSICHT     Die Zentrifuge wiegt ca  6 kg        4 4 Verpackung    74        Zentrifuge zum Transport in der Originalverpackung verpacken  siehe   Kapitel  4 4   Verpackung       Die Zentrifuge ist in einem Karton verpackt        Karton   ffnen        Zubeh  r entnehmen      Zentrifuge mit den Schaumstoffteilen aus dem Karton heben  Beim Heben  der Zentrifuge grunds  tzlich seitlich ansetzen        A    VORSICHT     Die Zentrifuge wiegt ca  6 kg        Lagerung und Transport      Verpackung f  r evtl  sp  teren Transport der Zentrifuge aufbewahren        5 1 Aufstellort    5 2 Energieversorgung    5 2 1 Anschlussart    5 2 2 Sicherungen bauseits    5  Aufstellung und Anschluss    Die Zentrifuge darf nur in geschlossenen und trockenen R  umen be
78. ity must be considered      Before using cleaning or decontamination agents that were not recommended by  us  contact the manufacturer to ensure that such a procedure will not damage the  centrifuge        For autoclaving  consider the continuous heat resistance of the individual  materials  see   chapter 8 2 1  Autoclaving          Please contact the manufacturer if you have any queries           A    WARNING        If dangerous materials  e g  infectious and pathogenic substances  are used  the  centrifuge and accessories must be disinfected        The service life of the accessories essentially depends on the frequency of autoclaving   and use        Replace the accessories immediately when the parts show changes in color or  structure or in the occurrence of leaks etc      During autoclaving  the caps of the tubes must not be screwed on in order to  avoid the deformation of the tubes        It cannot be excluded that plastic parts  e g  lids or carriers  may deform during  autoclaving        Maintenance and Service 35       Accessories Max  temp  Min  Max  Max                                                        C  time time cycles  Aluminum buckets 134 138 3 5    Aluminum rotors 134 138 3 5    Glass tubes 134 138 3 40    Rubber cushions 115 118 30 40    Polyallomer   polycarbonate rectangular 115 118 30 40    carriers  Polyallomer   polycarbonate round carriers 115 118 30 40    Polycarbonate   polyallomer lids for angle 115 118 30 40 20  rotors  Polycarbonate tubes 115
79. l safety  Operating elements  Operating voltage  Operational safety  Overseas shipping    Parameters   Performance data   Power consumption  Power supply   Protection class  Protection class   devices  Protective clothing  Protective conductor test  Protective earth  ground     Radioactive substances  Relative centrifugal force  Remaining hazards  Resistance data  Resistance of plastics  Rotor fastening nut  Rotor fixing screw   Rotor lid    12  38  39    15  22  32    19  7   39  39    24    9  20  30    33  14  30  35  44  21  34  33    20  22  33    39    10  14  39    26    13  45  9 25  19  33  18    11  22  24  26  39    39  10  39  19  39  39  19  39  15  24  12    34  27  40  17  47  16  20  21  20    Index    53       Safety distance   Safety devices   Safety instructions and hazard warnings  Safety instructions for centrifugation  Safety lock   Service life of rotors and accessories  Short run   Short run operations   Slushing oil   Soft stop   soft start   Solvents   Spare parts   Special notes   Startup   Statement of conformity  Sterilization   Storage   Storage temperature  Stress corrosion   Substances   Supply voltage   System check    Technical data  Transport lock    Vents    Weight    54 Index    14  16  14  15  16  16  28  28    28  33  37    20  51  35  18  18  34  34  19  17    39  18    19    18  39       F 13 01 Page    a 1 3 Return of material   i  Sartorius    01 Effective Date   biotech    01 01 2008       Declaration about decontamination and  clea
80. lied   The opening is located in the  base plate in the front quarter on the left hand side        A    CAUTION     If the lid is opened via the emergency lid release during a centrifuge run   the centrifuge will be switched off immediately and decelerate in a brakeless    manner            Switch the centrifuge off by actuating the mains power switch and by unplugging    the mains power plug         Pull the centrifuge a bit over the edge of the table and jack it up  e g  on two  wooden logs   Ensure that the center of gravity of the centrifuge is still located    above the table top       Insert the spanner for the emergency release into the hole  see the illustration   item 1  and attach it to the shaft of the lid lock motor          Turn the shaft carefully clockwise with the aid of the wrench until the lid opens           As a general rule  the lock can be opened more easily with the emergency lid  release system if the load on it is relieved by exerting slight pressure on the lid          Remove the spanner and pull the centrifuge back on the table     Overview 41       10 3 4 Problems with the Please contact your supplier in case of malfunction or parts queries   Centrifuge                 10 4 Error Mode The error mode is indicated by the message  ERR   The error numbers are displayed in  the time field   10 4 1 Table of Error codes Error no  Kind of error Measures  1 Tachometer signal is disturbed  Power off   on   4 Lid does not open after pressing Power off   on   
81. ltasten Set    6 4 2 Anzeigefeld    6 5 Starten einer  Zentrifugation    6 5 1 Unterbrechen einer  Zentrifugation    6 5 2 Unterbrechen eines  Bremsvorgangs    82 Betrieb    Mit diesen Tasten k  nnen Sie  1  im Laufmodus    umschalten von Drehzahlanzeige auf RZB     2  im Editiermodus      die Parameter ver  ndern                       17           C eG       SELECT SET START STOP    Baie eee                            1 Drehzahl    RZB Feld  2 Feld f  r Bremskurve und Laufmodus  3 Zeitfeld    Das Zentrifugendisplay besteht aus drei Anzeigefeldern    In der oberen Zeile erscheinen Drehzahl und Schwerefeld  in der unteren Zeile  kann die Laufzeit abgelesen werden  die mittlere Zeile signalisiert  soft stop  und   short run        Die Zentrifuge ist betriebsbereit  wenn der Netzschalter eingeschaltet und  der Deckel geschlossen ist       Start   Stop Taste dr  cken  um einen Lauf zu starten         Start   Stop Taste dr  cken  um einen Lauf zu unterbrechen   Der Lauf wird vorzeitig beendet         Durch Dr  cken der Start   Stop Taste wird der Bremsvorgang unterbrochen   Die Zentrifuge wird erneut gestartet        6 5 3 Drehzahl   Relative  Zentrifugalbeschleunigung   RZB     6 5 3 1   ndern des Dreh   zahl    RZB Wertes w  hrend  des Laufs    6 5 4 Laufzeit    6 5 4 1   ndern der Laufzeit  w  hrend des Laufs    Der RZB Wert ergibt sich aus der Rotorgeometrie und der Drehzahl  daher sind   RZB  und Drehzahl Werte voneinander abh  ngig  Die Eingabe eines der beiden Werte   legt 
82. m Formel  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL  Xylol Cl  100 3 1 4 1 4 4 4 4 1 1  Zinn  Il  chlorid SnCl  10 1 4 2 2 1       1 4  Zitronens  ure CHA  10 1 1 1 2 1 1 1 1 1 1  Zitronens  ure C H 0  50 1 3 1 2 1       1 1    106 Ubersicht             eec  22008   ILER                o    Konformit  tserkl  rung   73 23 EWG  89 336 EWG  98 37 EWG     Declaration de conformite   73 23 CEE  89 336 CEE  98 37 CEE     Firma   Company   Firme    sartorius    biotech    Statement of Conformity     73 23 CEE  89 336 CEE  98 37 CEE     Sartorius Stedim Biotech GmbH       Sitz   Address   Adresse    August Spindler Strasse 11  37079 Goettingen  Germany  Phone  49 551 308 0  Fax  49 551 308 32 89  www sartorius stedim com       Die nachfolgend bezeichnete Maschine wurde  in   bereinstimmung mit den Richtlinien 73 23 EWG   89 336 EWG und 98 37 EWG hergestellt und gepr  ft     The following machine is manufactured and tested  in compliance with directions 73 23 CEE  89 336 CEE  and 98 37 CEE     La machine d  sign  e ci dessous est produit  et examin   conforme aux directives 73 23 CEE   89 336 CEE et 98 37 CEE       Bezeichnung der Maschine  Machine  D  signation de la machine    Laborzentrifuge  Laboratory Centrifuge  Centrifugeuse de laboratoire       Maschinentyp   Type   Type de la machine    Centrisart A 14             Bestell Nr  8581401  8581410  Part No  _  Ref  usine E  Normen EN 61010 2 020  Standards EN 61000 3 2  EN 61000 3 3  Normes EN 61326  NA  A  sy  Datum   Unterschri
83. miring f  r Mikroh  matokritrotor  BBI 8583501  BBI 8586837  Kapillarverschlussmasse  12 plates   BBI 8587299  Ablesescheibe f  r H  matokritrotor 11026  DCCO304W K   VoluPAC R  hrchen zur Bestimmung der  Zellmasse  PCV   50 St  ck  1 Packung  DCCO304W S   VoluPAC R  hrchen zur Bestimmung der    Zellmasse  PCV   200 St  ck  1 Packung    Weiteres Zubeh  r auf Anfrage lieferbar        M  gliche H  chstdrehzahlen von Gef    en   Einige GefaBe wie z B  Zentrifugenglaser  Mikrogef  Be  Kulturr  hrchen   Polyfluorr  hrchen und insbesondere Gef    e mit gro  em Fassungsverm  gen  k  nnen in unseren Rotoren  Bechern und Adaptoren mit h  heren Drehzahlen  als deren Bruchgrenze gefahren werden  Wir empfehlen  die Gef    e grund   s  tzlich voll zu f  llen und die Empfehlungen der Gef    hersteller zu beachten           10 7 Dekontaminationser   kl  rung   R  cksendeerkl  rung    Die beiliegende Erkl  rung dient der Arbeitssicherheit und Gesunderhaltung unserer  Angestellten  F  gen Sie die Formbl  tter ausgef  llt bei R  cksendung von Zentrifugen     Ersatzteilen und Zubeh  r bei     Bitte haben Sie Verst  ndnis daf  r  dass wir die Arbeiten nur beginnen k  nnen     wenn die Erkl  rungen vorliegen      Wir empfehlen  diese Seiten mehrfach zu kopieren     Dekontaminationserkl  rung   R  cksendeerkl  rung s  Anlage     10 8 Drehzahl Schwerefeld Diagramm       UD VIII    Win WU al    I c MI  Ma E Late  uf     lena    LA A KA              d  s PTT  ss p    7 if             NN    man  H  a 
84. nahmen zur Wahrung der Betriebssicherheit            Fl  ssigkeiten  die Korrosion verursachen k  nnen  m  ssen unverz  glich von  Rotor  Becher und Zubeh  r unter flie  endem Wasser abgesp  lt werden  Zum  Reinigen der Bohrungen von Winkelrotoren eine Reagenzglasb  rste verwenden   Anschlie  end den Rotor auf dem Kopf liegend vollst  ndig trocknen lassen        Zubeh  r au  erhalb der Zentrifuge reinigen  am besten nach jedem Gebrauch   mindestens aber einmal w  chentlich  Dabei vorhandene Adapter entnehmen     Wartung und Instandhaltung 89          A    VORSICHT     Zubeh  r niemals in der Geschirrsp  lmaschine reinigen   In der Geschirrsp  lmaschine wird die Eloxalschicht entfernt  die Folge ist  Rissbildung an den beanspruchten Stellen        8 1 2 1 Kunststoffzubeh  r    8 1 3 Rotoren    8 1 4 Mikroh  matokritteller    90    Wartung und Instandhaltung        Rotoren und Zubeh  r bei einer toxischen  radioaktiven oder pathogenen  Kontamination sofort mit einem geeigneten Dekontaminationsmittel  abh  ngig  von der Art der Verunreinigung  reinigen  Zum Eigenschutz unbedingt  entsprechende Vorsichtsma  nahmen einhalten  falls die Gefahr der toxischen   radioaktiven oder pathogenen Kontamination besteht        Zubeh  r ggf  mit einem weichen Tuch oder in einem Trockenschrank bei ca   50  C trocknen     Mit zunehmender Temperatur  z B  beim Trocknen  verringert sich die Chemikalien    best  ndigkeit von Kunststoffen  siehe   Kapitel 10 10    Best  ndigkeitstabelle        Kunst
85. nce of Plastics   eee 16  3 6 7 Service Life of Rotors and Accessories          16  3 7    Safety Delega 16  3 7 1 Lid Lock Device          sssseseseseesse 16  3 7 2 System Check    oce Sets 17  3 8 Measures in the Event of Hazards and Accidents     17  3 9 Remaining Hazards      17  4  Storage and Transport    18  4 1 Dimensions and Weight    18  4 2 Storage Conditions    18  4 3 Shipping Instructions          csse 18  4 4  Packaging      i eee anne 18  5  Set up and Connection    19  5 1 Installation Site    19  5 2 Power Supply in 19  5 2 1   Connection NEEN des EEN Dn 19  5 2 2 Customer provided Fuses            22         19    6  Operation     6 1 InmpalStart up   00    e eee  6 2 Switching on the Centrifuge  cesses    6 2 1 Opening and Closing the Lid                     6 2 2 Installation of Rotors and Accessories           6 2 2 1 Installation of the Rotor                 6 2 2 2 Installation of  Microhaematocrit Rotor                 6 2 2 3 Installation of Accessories               EN UE  6 3 Centrifuge Description     6 3 1 Overview    ae  6 3 2 Setup and Constructive Safety Practices        6 3 3  Dees Ae Se  6 3 4 Operation and Display     6 3 5  Electr  ni ara Ehe  6 3 6 Safety Devices 0  cece cece eee ee  6 3 6 1 Lid Lock Device  Lid Clamp              6 3 6 2 System Check     6 3 6 3 Grounded Conductor Test               6 4 Operating Elements  ee eee  6 4 1 Control Panel     6 4 1 1 Start  Stop Key                          6 4 1 2 Select Key     6 4 1 3 Ddke
86. ning of equipment and components    When returning equipment or components  please describe on page 2 of this form the problem s  or fault s  you have found  Please  also indicate the remedial actions you require     To protect our personnel  we require all equipment or components be free of biological  chemical  or radioisotopic contaminants  We  will only accept such equipment or components when     e the equipment or components have been adequately cleaned and decontaminated   e this declaring document has been completed  signed and returned by an authorized person     Please help us in assuring a safe  hazard free work environment        A  Description of the Equipment or Component s           Description   Cat  No        Serial no        No  of invoice delivery note          Date of delivery          B  Contamination   Cleaning             Attention  Please specify exactly the biological  chemical  or Attention  Please describe the cleaning and decontamination  radioisotopic contaminant procedure method  The equipment was contaminated with and it has been cleaned and decontaminated by                Declaration of Decontamination 55       F 13 01 Page    2 3 Return of material i i sartorius    Version  01    Effective Date   biotech  01 01 2008          C  Legally binding declaration    1  we  certify that all information given in this form is correct and complete   The equipment and components have been adequately decontaminated and cleaned according to the legal requir
87. ntion of accidents must be  complied with     Centrifuges are power driven machines that separate liquids from solid matter  liquid  mixtures  or solid mixtures by centrifugal force  They are solely intended for this  purpose  Any other use beyond this area of application is regarded as improper use   Sartorius Stedim Biotech GmbH cannot be held liable for any damage resulting from  such improper use     The intended use also includes      observation of all the notes and instructions included in the operating manual and    compliance with the care  cleaning and maintenance instructions     The warranty and liability are subject to our  General Conditions    that were  distributed to the operator upon the conclusion of the contract     Warranty and liability claims are excluded if they are due to one or more of the   following      improper use      non compliance with the safety instructions and hazard warnings in the operating  manual      improper installation  start up  operation or maintenance of the centrifuge     The centrifuge comprises      connection cable  part no  269010     rotor fastening nut  part no  80301     spanner for emergency lid release     1 bottle of slushing oil     spare fuse    General Information 7       Accessories according to your order  our order confirmation and our delivery note     Rotor part no  Rotor no     General Information       2 1 Layout of the Centrifuge    2 1 1 Functional and  Operating Elements    2  Layout and Mode of Operation
88. on       Temperature value cannot  be reached  only for  refrigerated centrifuges     Condenser dirty    Contact service       7 1 1 Emergency Lid Release    In the event of a power failure  it is possible to manually open the centrifuge lid with   a socket spanner  part no  930 014  included in the equipment supplied   The opening   is located in the base plate in the front quarter on the left hand side        Switch the centrifuge off by actuating the mains power switch and by unplugging  the mains power plug        Pull the centrifuge a bit over the edge of the table and jack it up  e g  on two   wooden logs   Ensure that the center of gravity of the centrifuge is still located   above the table top  If necessary  the unit must be secured by a second person    Insert the spanner for the emergency release into the hole  see the illustration    item 1  and attach it to the shaft of the lid lock motor    Turn the shaft carefully clockwise with the aid of the wrench until the lid opens    Remove the spanner and pull the centrifuge back on the table        Notentriegelung    ffnen     Emergency Door Release  Open      d    Fig  12  Opening for the emergency lid release at the bottom of the centrifuge          A    WARNING     Do not unlock the lid unless the rotor is at a standstill and unless there is no  danger to other persons        If the lid is opened via the emergency lid release during a centrifuge run  the  centrifuge will be switched off immediately and decelerate in 
89. ondert  darauf hinzuweisen     Aufgrund der st  ndigen Weiterentwicklung der Ger  te besteht die M  glichkeit  dass  einzelne Bauteile bzw  ihre Bedienung nicht beschrieben sind  Auch k  nnen Angaben  enthalten sein  die f  r Ihr Ger  t nicht zutreffen  Sollten f  r Sie wichtige Informationen  fehlen  sollten Sie sachliche Fehler finden oder ausf  hrlichere Informationen zu  einzelnen Bauteilen w  nschen  weisen Sie uns bitte darauf hin     Die Mikrozentrifuge CENTRISART  A  14 ist ein Beispiel aus dem Laborger  te   programm der Sartorius Stedim Biotech GmbH    Das weitere Ger  teprogramm umfasst Sch  ttler und Sch  ttelinkubatoren   Homogenisatoren  Zentrifugen  Reinstwasseranlagen  Luftkeimsammler und  Fermenter   Bioreaktoren  Weitere Informationen finden Sie auf unserer  Internetseite www sartorius stedim com      ber unser gesamtes Produktprogramm informieren wir Sie gern auf Anfrage     Sartorius Stedim Biotech GmbH  August Spindler Stra  e 11  37079 G  ttingen  info sartorius stedim com  www sartorius stedim com    Besondere Hinweise 61       1 1 Stellenwert der  Betriebsanleitung    1 2 Bestimmungsgem    e  Verwendung    1 3 Gew  hrleistung und  Haftung    1 4 Lieferumfang    1  Allgemeine Informationen    Grundvoraussetzung f  r den sicherheitsgerechten Umgang und den  st  rungsfreien Betrieb dieses Ger  ts ist die Kenntnis der grundlegenden Sicherheits   und Gefahrenhinweise     Die Betriebsanleitung enth  lt die wichtigsten Hinweise  um die Zentrifuge  sicherheits
90. onsspuren  oder andere Besch  digungen aufweisen      Nur vom Hersteller zugelassene Rotoren und Zubeh  rteile verwenden    Im Zweifelsfall R  cksprache mit dem Hersteller halten      Beim SchlieBen des Deckels niemals mit den Fingern zwischen Deckel und  Geh  use greifen  Quetschgefahr      Defekte Deckelentlastungen erm  glichen das Herunterfallen des Zentrifugen   deckels  ggf  Service verst  ndigen   Quetschgefahr      Das AnstoBen oder Bewegen der Zentrifuge w  hrend des Betriebes ist  verboten      Das Anlehnen an oder Abst  tzen auf der Zentrifuge wahrend des Betriebes  ist verboten      Keine Substanzen zentrifugieren  die das Material von Rotoren  Eins  tzen oder  Zentrifuge beschadigen k  nnen  Stark korrodierende Substanzen verursachen  z B  Materialsch  den und beeintr  chtigen die mechanische Festigkeit von  Rotor und Eins  tzen          Zentrifuge bei Funktionsst  rungen sofort au  er Betrieb nehmen  St  rung   beseitigen  siehe  gt  Kapitel 7    St  rungen und Fehlersuche     oder ggf  den  WARNUNG  Sartorius Service informieren      Reparaturen nur von autorisiertem Fachpersonal durchf  hren lassen      Zentrifuge  Rotor und Zubeh  r vor jeder Inbetriebnahme auf   u  erlich  erkennbare Sch  den   berpr  fen  insbesondere bei allen Gummiteilen   z B  Motorabdeckung  Deckeldichtung  Adapter  auf sichtbare Strukturver  n   derungen achten  Mangelhafte Teile m  ssen sofort ausgetauscht werden      Bei Nichtgebrauch der Zentrifuge den Deckel   ffnen  damit evtl  vo
91. organg wird hier durch den Einsatz von Laborzentrifugen enorm verk  rzt       In der metallverarbeitenden Industrie werden Zentrifugen zum Ent  len von  Metallsp  nen genutzt  Molkereien setzen Zentrifugen ein  um damit z B  Kuhmilch  in Sahne und fettreduzierte Milch zu trennen       Besonders gro  e Zentrifugen kommen in der Zuckerindustrie zum Einsatz   In ihnen wird der Sirup vom kristallinen Zucker getrennt       Die Ultrazentrifuge findet vor allem Anwendung in der Biologie und Biochemie   um Partikel wie z B  Viren zu isolieren  Sie ist eine f  r hohe Geschwindigkeiten  konzipierte Zentrifuge mit bis zu 500 000 U min  Der Rotor bewegt sich im Vaku   um  um Luftreibung zu vermeiden     Die Beschleunigung g  der die Proben ausgesetzt sind  kann durch eine Vergr    erung  des Radius im Rotorraum und durch die Erh  hung der Drehzahl vergr    ert werden   Diese drei Parameter sind voneinander abh  ngig und   ber folgende Formel mitein   ander verkn  pft     Relative Zentrifugalbeschleunigung RZB   11 18 x10 5x rx n     r   Radius in cm  n   Drehzahl in min      RZB dimensionslos    Bei der Eingabe von zwei Werten ist der dritte   ber die angegebene Gleichung  festgelegt  Wird danach die Drehzahl oder der Radius verandert  wird die daraus  resultierende Relative Zentrifugalbeschleunigung von der Steuerung der Zentrifuge  automatisch neu errechnet  Wird die RZB ver  ndert  wird die Drehzahl unter  Verwendung des vorgegebenen Radius entsprechend angepasst     Eine   bersicht  
92. p   amp   Medium Formel  9o  HDPE PA PC POM PP PSU PVC PVC PTFE AL  Acetaldehyd C H 0 40 3 2 4 2 3 4 4   1 1  Acetamid C H NO gesattigt 1 1 4 1 1 4 4   1 1  Aceton CHA 100 1 1 4 1 1 4 4   1 1  Acrylnitril CHA 100 1 1 4 3 3 4 4 4 1 1  Allylalkohol C H 0 96 1 3 3 2 2 2 2 4 1 1  Aluminiumchlorid AICl  gesattigt 1 3 2 4 1   1   1 4  Aluminiumsulfat Al  SO    10 1 1 1 3 1 1 1 1 1 1  Ameisens  ure CH 0  100 1 4 3 4 1 3 3 1 1 1  Ammoniumchlorid  NH  CI wassrig 1 1 1 2 1 1 1 1 1 3  Ammoniumhydroxid NH    H O 30 1 3 4 1 1 2 1   1 1  Anilin CHN 100 1 3 4 1 2 4 4 4 1 1  Antimontrichlorid SbCl  90 1 4 1 4 1   1   1 4  Benzaldehyd C H 0 100 1 3 4 1 1 3 4 4 1 1  Benzin CH    Col 100 2 1 3 1 3 3 2   1 1  Benzol C H  100 3 2 4 1 3 4 4   1 1  Benzylalkohol C H40 100 3 4 4 1 4 4 2   1 1  Bors  ure H4BO  wassrig 1 3 1 2 1       1 1  Butanol C H  0 100 1 1 2 1 1 2 2 4 1 1  Butylacrylat C H 50  100 1 2 4 2 3 4 4 4 1 1  Calciumchlorid CaCl  alkoholisch 1 4 2 3 1     4 1 3  Chlor Cl  100 4 4 4 4 4 4 4 4 1 3  Chlorbenzol C H Cl 100 3 4 4 1 3 4 4 4 1 1  Chloroform CHCI  100 3 3 4 4 3 4 4 4 1 3  Chlorwasser Cl  x H 0 3 4 4 4 3   3 3 1 4  Chromalaun KCr SO    x 12H 0 ges  ttigt 1 2 1 3 1 1   1 3  Chroms  ure CrO  10 1 4 2 4 1 1   1 1  Cyclohexanol C H  0 100 1 1 3 1 1 1 4 1 1  Decan Ci oH  100   1 2 1 3       1 1  Dichlormethan CH Cl  100 4 3 4 3 3 4 4 4 1 1  Diesel  l Er 100 1 1 3 1 1   1 3 1 1  Dimethylanilin C H  N 100   3 4 2 4       1 1  Dimethylformamid C4D NOv 100 1 1 4 1 1 4 3   1 1   DMF   Dim
93. packung    74   5  Aufstellung und Anschluss    75   5 1 Aufstellort        sess 75   5 2 Energieversorgung  26  c cece ee eeeee eee eens 75   5 2 1 Anschlussart       cece eee e eee ees 75   5 2 2 Sicherungen bauseits            iesiceee eee 75    6  Betrieb   200    cence ences  6 1 Erste Inbetriebnahme                                  6 2 Dnschalten  00    c cece cece eee   6 2 1   ffnen und Schlie  en des Deckels               6 2 2 Einsetzen von Rotoren und Zubeh  r            6 2 2 1 Einsetzen des Rotors                    6 2 2 2 Einsetzen des Mikroh  matokrit   tellers ee een  6 2 2 3 Einsetzen von Zubeh  r                  6 224  Gef    e  erinra eme  6 3 Zentrifugenbeschreibung            2    cece eee eee  6 3 1   bersicht     6 3 2 Aufbau und konstruktive  Sicherheitsma  nahmen                          6 3 3 Antrieb a saeta eara En RE NEEE  6 3 4 Bedienung und Anzeige             sssussssue   6 3 5 Elektronik         00    00 00 ccc cece cece eee ee  6 3 6 Sicherheitseinrichtungen         csisccicecis  6 3 6 1 Deckelverriegelung   Deckelzuhaltung                         6 3 6 2 Systemkontrolle                         6 3 6 3 Schutzleiterpr  fung                     6 4 Bedienelemente  00    c ccc cece eee  6 4 1 Bedienfeld dees  6 4 1 1 Taste Startlstop  eee  6 4 1 2 Taste Select                              6 4 1 3 Taste Deckel                             6 4 1 4 Pfeiltasten Set                           6 4 2 Anzeigeield 00 cece eee  6 5 Starten einer Zentrifuga
94. play    keine Spannung im Netz    Netzsicherung   berpr  fen       Netzstecker steckt nicht    Netzstecker fest einstecken       Netzschalter aus    Netzschalter einschalten       Deckel ist nicht korrekt  geschlossen    Deckel schlie  en       Zentrifuge l  sst sich  nicht starten  Sollwert   Drehzahl wird  unver  ndert angezeigt    diverse    Netz aus   ein  Falls sich  der Fehler wiederholt   Service verst  ndigen       das Deckelschloss ist nicht  korrekt geschlossen    Deckel   ffnen und  schlie  en  Falls sich der  Fehler wiederholt   Service verst  ndigen          Zentrifuge bremst diverse Netz aus   ein  Falls sich der  wahrend des Laufs ab und Fehler wiederholt  Service  zeigt nach erneutem verstandigen   Einschalten einen Fehler   aus der Gruppe 1 18 an   Zentrifuge bremst diverse durch Bestatigen der    wahrend des Laufs ab und  zeigt Fehler 19 an    Deckeltaste quittieren       Temperaturwert wird  nicht erreicht  gilt nur fiir  K  hlzentrifugen     Kondensator verschmutzt    Service verstandigen       7 1 1 Notentriegelung       Bei z  B  Stromausfall besteht die M  glichkeit  den Zentrifugendeckel manuell mit   einem Steckschl  ssel  Best  Nr  930 014  im Lieferumfang enthalten  zu   ffnen  Die     ffnung befindet sich am Bodenblech im linken vorderen Viertel      Zentrifuge am Netzschalter ausschalten und Netzstecker ziehen        Zentrifuge ein St  ck   ber die Tischkante ziehen und aufbocken  z B  auf zwei  Holzkl  tzen   dabei darauf achten  dass sich der Sc
95. pull the safety lock in the middle of the lock upwards and  put the lid on the rotor  The snap on lid will be locked when the safety lock is  released        A    WARNING     Once a day or after 20 cycles  the rotor tie down screw must be loosened by  some turns and the rotor must be lifted and fastened again  This ensures a  proper connection between the rotor and the motor shaft            Rotors can be used without a cover  This leads  however  to higher levels of noise  and temperatures when running     Follow the safety instructions and hazard warnings  see   chapter 3  Safety                Fig  7  Microhaematocrit rotor  part no  11026  with reader  part no  17028     Operation 21                      Fig  8  Rotor fastening nut from above  A   and below  B     6 2 2 3 Installation of  Accessories    22 Operation        Unscrew the rotor fastening nut from the motor shaft  counterclockwise         Lower the microhaematocrit rotor with its central bore straight down onto the  motor shaft      Hand tighten the rotor fastening nut clockwise  corresponds to 1 Nm   The rotor  fastening nut and conical spring washer must face the microhaematocrit rotor   i e  the writing must be shown on top      1 Conical spring washer      Follow the safety instructions and hazard warnings  see   chapter 3  Safety       Operation       Fill the capillary tubes with blood and seal them at one end with putty or by  fusion        Place the capillary tubes into the recesses of the rotor with t
96. r  ft werden     Der Unternehmer  Betreiber  hat gem     den internationalen Regeln f  r   Gesundheit und Sicherheit am Arbeitsplatz  nur in D  Berufsgenossenschaftliche   Regeln BGR 500 Kap  2 11 Teil 3      Ma  nahmen zur Verh  tung von Gefahren f  r Leben und Gesundheit bei der  Arbeit zu ergreifen      daf  r zu sorgen  dass Zentrifugen bestimmungsgem     betrieben werden   siehe   Kapitel 1 2    Bestimmungsgem    e Verwendung        MaBnahmen zum Schutz gegen Brand und Explosion bei der Arbeit mit gefahr   lichen Stoffen zu ergreifen        Ma  nahmen zum sicheren   ffnen von Zentrifugen zu ergreifen     Das Ger  t darf nur bedienen  wer     mit den grundlegenden Vorschriften   ber Arbeitssicherheit und Unfallverh  tung  vertraut ist       diese Betriebsanleitung  insbesondere die Sicherheitskapitel und die Warnhinweise   gelesen und verstanden hat und dies durch seine Unterschrift bestatigt hat       Die Betriebsanleitung ist Teil des Produktes      Die Betriebsanleitung ist st  ndig am Standort der Zentrifuge aufzubewahren und  muss jederzeit einsehbar sein        Die Betriebsanleitung muss an jeden nachfolgenden Besitzer oder Benutzer der  Zentrifuge weitergegeben werden        Jede erhaltene   nderung ist zu erg  nzen      Erg  nzend zur Betriebsanleitung sind die allgemeing  ltigen sowie die betriebli   chen Regelungen zur Unfallverh  tung und zum Umweltschutz bereitzustellen      Alle Sicherheits  und Gefahrenhinweise an der Zentrifuge sind in lesbarem Zu   stand z
97. r Deckel   ffnet        Grunds  tzlich l  sst sich das Schloss leichter per Notentriegelung   ffnen   wenn es durch leichten Druck auf den Deckel entlastet wird          Notentriegelungsschl  ssel abziehen und Zentrifuge wieder komplett auf die  Tischplatte stellen       bersicht 97       10 3 4 Servicefall  was tun  Bitte setzen Sie sich zur Unterst  tzung und bei evtl  St  rungen oder Ersatzteil   anfragen mit Ihrem Lieferanten in Verbindung     10 4 Fehlermodus Der Fehlermodus wird durch    ERR  signalisiert  Die Fehlernummern werden im  Zeitfeld angezeigt                 10 4 1 Fehlertabelle Fehler Nr  Fehlerart Ma  nahmen  1 Tachosignal gest  rt  Netz aus   ein    4 Deckel   ffnet sich nach Bet  tigen Netz aus   ein    der Deckeltaste nicht  Notentriegelung betatigen   2 3  5 18 Interner Fehler  Netz aus   ein      19 Stromausfall wahrend des Laufes  Deckel   ffnen nach Stillstand  des Rotors     Fehlermeldung durch Bet  tigen  der Deckeltaste quittieren        Sollten die Fehler sich nicht beheben lassen  Service verst  ndigen             Zeigt das Display  ERR  im Wechsel mit  SAFE   Netz aus   ein erst nach Anzeige von  OFF  bet  tigen     98   bersicht       10 5 Zubeh  r f  r CENTRISART    A 14                      Bestell Nr  Beschreibung H  chstdrehzahl Max  Schwerefeld   min     x 9    BBI 8583439 Winkelrotor 12 x 1 5 2 2 ml  f  r z B  Reaktionsgef    e Nr  15008  14 800 15 183  15040  einschl  Deckel aus Polysulfon Nr  17882   BBI 8583447 Winkelrotor 18 x 1 5 2 
98. rhandene  Fl  ssigkeiten verdampfen k  nnen        70 Sicherheit          3 6 3 Brandschutz      Das Zentrifugieren von explosiven oder brennbaren Substanzen ist verboten     Zentrifuge keinesfalls in explosionsgef  hrdeter Atmosph  re betreiben            AusschlieBlich Sicherungen des angegebenen Typs und Nennwerts verwenden     WARNUNG           3 6 4 Chemische und Wenn infekti  se  toxische  pathogene oder radioaktive Substanzen zentrifugiert   biologische Sicherheit werden sollen  ist der Benutzer daf  r verantwortlich  dass alle zutreffenden  Sicherheitsvorschriften  Richtlinien  Vorsichts  und SicherheitsmaBnahmen einge   halten werden          Infekti  se  toxische  pathogene und radioaktive Substanzen d  rfen nur  in speziellen  zertifizierten Verschlusssystemen mit Bioabdichung eingesetzt  WARNUNG  werden  um eine Freisetzung von Material zu verhindern       Zum eigenen Schutz unbedingt entsprechende VorsichtsmaBnahmen  einhalten  falls die Gefahr der toxischen  radioaktiven oder pathogenen  Kontamination besteht      Das Zentrifugieren von Materialien  die chemisch mit hoher Energie  miteinander reagieren  ist verboten            rtliche Ma  nahmen zur Eind  mmung sch  dlicher Emissionen unbedingt  beachten  abh  ngig von den zu zentrifugierenden Substanzen     GI T Schutzkleidung ist zum Betrieb der Zentrifuge nicht erforderlich    Moglicherweise erfordert das zu zentrifugierende Material besondere   SicherheitsmaBnahmen  z B  die Zentrifugation von infekti  sen  
99. rreicht werden kann     Zur Auswahl eines Rotors die Select Taste dr  cken und ca  2 Sekunden   gedr  ckt halten    Mit den Auf    Ab Tasten die Kennzahl des eingesetzten Rotors aus der folgenden  Liste ausw  hlen           Kennzahl 1 2 3 4 5  Rotor 11026 12082 12083 12084 12085  Kennzahl 6 7 8 9 10  Rotor 12092 12093 12094 12096       Select Taste dr  cken  um die Eingabe zu best  tigen     Der RZB Wert wird dem ausgew  hlten Rotor angepasst           Die Rotorauswahl wird auf dem jeweiligen Programmplatz gespeichert          Zentrifuge bei Nichtgebrauch   ffnen  damit evtl  Feuchtigkeit entweichen kann     Zentrifuge am Netzschalter ausschalten     Betrieb 85       7 1 Allgemeine St  rungen    7  Storungen und Fehlersuche    St  rungen werden als Fehlermeldung mit einer Nummer im Drehzahl       RZB Display angezeigt     Bei einem schwerwiegenden Fehler  z B  Defekt des Deckelschlosses  l  uft eine  Sicherheitszeit ab  die im Display heruntergez  hlt wird  W  hrend dieser Zeit blinken     ERR  und    SAFE  im Wechsel  Nach Ablauf der Auszeit erscheint die Anzeige  OFF            WARNUNG        Zentrifuge erst ausschalten  nachdem im Display   OFF  angezeigt wird  Nur so  ist gew  hrleistet  dass der Rotor vollst  ndig zum Stillstand gekommen ist        86 St  rungen und Fehlersuche        Fehlerquelle beheben  Tabellen siehe unten        Fehlermeldungen durch Dr  cken der Deckeltaste quittieren     Fehlerart    m  gliche Ursachen    Behebung       Keine Anzeigen auf dem  Dis
100. sage  short run  and the duration of the short run are displayed and the time  counts upwards in seconds for the duration of the short run  When the Start   Stop  key is released  the centrifuge decelerates at maximum power to a standstill     After the short run  the lid unlocks automatically and the parameters set beforehand  are displayed again     During the continuous run  the runtime of the centrifuge is unlimited and must be   stopped manually  The centrifuge accelerates during the continuous run until the set   speed is reached      To start the continuous run  press the select key until the time unit flashes on the  display        Press the down key  arrow key  until the display switches from  00  10  to             After 99 min 59 sec  any additional runtime will no longer be displayed    but the centrifugation will continue        To stop a continuous run  press the Start   Stop key  The centrifugation will end       Enter a runtime  The centrifugation will end after this time     The softstart function is used to extend the acceleration time  whereas the softstop   function is used to extend the deceleration time  The current combination is shown   on the display        To activate the softstart and softstop functions  press the select key repeatedly  until  Softstop   start  flashes in the upper left part of thedisplay        Press the arrow keys until  Softstop   Start on  is displayed  The softstart and  softstop functions are now activated        Press the sel
101. sch  den  kann beim Hersteller kein Garantieanspruch und keine Haftung  geltend gemacht werden          Zur Reinigung der Zentrifuge und des Zubeh  rs Seifenwasser oder andere  wasserl  sliche  milde Reinigungsmittel mit einem pH Wert zwischen 6 und 8  verwenden      Atzende und aggressive Stoffe vermeiden        Keine L  semittel verwenden        Keine Mittel mit Scheuer  oder Sch  rfbestandteilen verwenden      Zentrifugen und Rotoren d  rfen keiner intensiven UV Strahlung  z B  Sonnenein   strahlung  sowie thermischen Belastungen  z B  durch W  rmeerzeuger  ausgesetzt  werden       Vor der Reinigung der Zentrifuge den Netzstecker ziehen      Sorgf  ltig Fl  ssigkeiten wie Wasser  L  semittel  S  uren und Laugen mit einem  Tuch aus der Rotorkammer entfernen  So wird eine Besch  digung der Motorlager  verhindert      Innenraum der Zentrifuge bei einer Kontamination durch toxische  radioaktive  oder pathogene Substanzen sofort mit einem geeigneten Dekontaminationsmittel   abh  ngig von der Art der Verunreinigung  reinigen        WARNUNG     Zum Eigenschutz unbedingt entsprechende Vorsichtsma  nahmen einhalten   falls die Gefahr der toxischen  radioaktiven oder pathogenen Kontamination  besteht          Motorwelle nach der Reinigung mit Tragbolzenfett leicht einfetten und das  Fett mit einem Tuch zu einer sehr d  nnen Schicht verteilen        VORSICHT     Die besonderen VorsichtsmaBnahmen bei der Pflege des Zubeh  rs sind  unbedingt zu beachten   Es handelt sich hierbei um MaB
102. sion       Achtung  Betriebsanleitung lesen  Attention  consult the instruction manual  Attention  consulter le mode d emploi       Ein  Netzverbindung   On  Power   Marche  mise sous tension        Aus  Netzverbindung   Off  Power   Arr  t  mise hors tension        Schutzleiteranschluss  Protective earth  ground   Raccord a la terre           eo p gt     Erde  Earth  ground   Terre          Netzstecker ziehen  Unplug the mains plug  Debrancher la prise       Vorsicht Quetschgefahr  Caution  Risk of bruising  Attention   Risque de blessure       Drehrichtungspfeil  Arrow indicating the direction of rotation  Fleche de sens de rotation       Hei  e Oberfl  che  Hot surface  Surface chaude       CE Zeichen gem     Richtlinie 2006 42 EG  CE mark in compliance with the Directive 2006 42 EC  Symbole CE conforme    la directive 2006 42 CE       AP lp    Nicht mit dem Hausm  ll entsorgen  Do not dispose as part of domestic waste  Ne pas jeter avec les d  chets m  nager          3 2 Explanation of the  Symbols and Notes    3 3 Responsibility of the  Operator    3 4 Operating Personnel    3 5 Informal Safety  Instructions    The operating manual uses the following names and symbols to indicate hazards        A    WARNING     This symbol stands for a potential hazard to the life and health of persons   Non observance of these symbols can cause serious health problems up to  life endangering injuries         gt     CAUTION     This symbol stands for a potential hazard to the life and he
103. speeds up to  500 000 rpm  The rotor moves in a vacuum in order to avoid air friction     The acceleration g  which the samples are subject to  can be increased by increasing  the radius in the rotor chamber and by increasing the speed  These three parameters  are interdependent and linked with each other via the following formula     Relative centrifugal force RCF   11 18 x 10 6 x rx n     r   radius in cm  n   speed in min   RCF without any dimension    If two values are entered  the third value is determined by way of the stated formula   If  afterwards  the speed or the radius is changed  the resulting relative centrifugal  force will be recalculated automatically by the control unit  If the RCF is changed   the speed will be adapted while the specified radius is maintained     The speed gravitational field diagram provides an overview of the relationship  between speed  radius and RCF  see  gt  chapter 10 8  Speed gravitational field  diagram       The information concerning the speed of rotors and accessories refers to liquids with  a density that is lower than 1 2 g cm   If the density is above this value  the maximum  permissible speed of the centrifuge is reduced based on the following formula     n   Nmax x    1 2 Rho    Rho   density in g cm     Layout and Mode of Operation 11       3 1 Marking of the Unit    12    Safety    3  Safety    The following symbols are used for the centrifuges        Gef  hrliche elektrische Spannung  Dangerous voltage  Courant haute ten
104. stoffzubeh  r nach der Arbeit mit L  semitteln  S  uren oder Laugen  sorgf  ltig reinigen     Die Rotoren sind mit h  chster Pr  zision gefertigt  um den st  ndigen hohen  Belastungen ihres Einsatzbereiches bei hohen Schwerefeldern widerstehen zu  k  nnen     Chemische Reaktionen sowie Druckkorrosion  Kombination von wechselndem  Druck und chemischer Reaktion  k  nnen das Gef  ge der Metalle angreifen bzw   zerst  ren  Kaum nachweisbare Risse an der Oberfl  che vergr    ern sich und  schw  chen das Material  ohne deutlich sichtbare Anzeichen daf  r zu hinterlassen       Das Material muss daher regelm    ig  mindestens einmal monatlich    berpr  ft   werden auf     Rissbildung     sichtbare Gef  gezerst  rungen an der Oberfl  che     Druckstellen     Korrosionserscheinungen     sonstige Ver  nderungen       Bohrungen von Rotoren pr  fen       Besch  digte Teile im Interesse der eigenen Sicherheit unverz  glich austauschen       Mikroh  matokritteller zum Reinigen entnehmen        Rotorkammer auswischen      Gummiring bei VerschleiB bzw  Glasbruch austauschen   Best  Nr  16002 f  r Rotor 11026         8 1 5 Glasbruch    8 2 Sterilisation und  Desinfektion von  Rotorkammer und Zubeh  r    8 2 1 Autoklavieren       A    VORSICHT     Bei Glasbruch m  ssen s  mtliche Splitter sofort und vollst  ndig  z B  mit   einem Staubsauger  entfernt werden  Gummieins  tze m  ssen erneuert werden   da auch nach gr  ndlicher Reinigung nicht alle Glaspartikel entfernt werden  k  nnen          Gl
105. ststoffen  Kunststoffen und somit ihre physikalischen Eigenschaften  Bei Arbeiten mit L  semitteln  S  uren  oder Laugen k  nnen Kunststoffteile gesch  digt werden        Best  ndigkeitstabelle beachten  siehe  gt  Kapitel 10 10  Best  ndigkeitstabelle             3 6 7 Lebensdauer von Rotoren und Zubeh  r haben eine begrenzte Lebensdauer   Rotoren und Zubeh  r    Aus Sicherheitsgr  nden ist eine regelm  Bige   berpr  fung  A  mindestens einmal monatlich  durchzufiihren   WARNUNG     Besonderes Augenmerk auf Veranderungen wie Korrosionsbildung  Anrisse     Materialabtragung etc richten      Nach 10 Jahren muss eine Pr  fung durch den Hersteller erfolgen      Nach 50 000 Zyklen ist der Rotor aus Sicherheitsgr  nden zu verschrotten      Sind auf Rotor oder Zubeh  r abweichende Angaben zur Lebensdauer  eingraviert  so gelten diese entsprechend  Zum Beispiel hat ein Becher mit  der Gravur    max  cycles   10 000  eine Lebensdauer von 10 000 Zyklen   ein Rotor mit der Kennzeichnung    Exp  Date 02 15  muss sp  testens im       Februar 2015 verschrottet werden  siehe Abbildung    e        13850    max cycles   10 000  gt   max load   e Q0  1  21009    Abb  4  Abweichende Lebensdauer   Gravur auf dem Becher   Rotor       Tabelle    Rotoren und Zubeh  r mit abweichender Lebensdauer  beachten   siehe  gt  Kapitel 10 9    Rotoren und Zubeh  r mit abweichender Lebensdauer             3 7 Sicherheitseinrichtungen    3 7 1 Deckelverriegelung Die Zentrifuge kann nur gestartet werden  wenn 
106. the lid key  Operate emergency release   2  3  5 18 Internal error Power off   on   19 Power failure during the run  Open the lid after the rotor has    come to a standstill   Acknowledge the error message  with the lid key        If it is impossible to eliminate the errors  Contact service          If the display shows  ERR  alternating with  SAFE   only press net on   off after  OFF  is displayed     42 Overview       10 5 Accessories Suitable for CENTRISART  A 14                               Part no  Description Maximum speed Max  gravitational   min    field  x g    BBI 8583439 Angle rotor 12 x 1 5 2 2 ml  for reaction vials  e g  no  15008  14 800 15 183  15040  incl  polysulfone lid no  17882   BBI 8583447 Angle rotor 18 x 1 5 2 2 ml for reaction vials  e g  15008  15040 14 800  or 18 x 0 25 0 4 ml for reaction vials e g  15014  2 lines  angle  42   48    incl  polysulfone lid 17882 15 673  Radius max  radius min  14 448  6 4 cm 3 2 and 2 5 cm  5 9 cm 3 6 and 2 5 cm   BBI 8583455 Angle rotor 24 x 1 5  2 2 ml  for reaction vials  e g  no  15008  14 800 16 163  15040  incl  polysulfone lid no  17882   BBI 8581096 Angle rotor 16 x 1 5  2 2 ml  for e g  reaction vials no  15008  14 800 15 673  15040  or 16 x 0 5 0 75 ml  e g  no  15005   2 lines  incl  13 713  polysulfone lid no  17882  Radius max  radius min   6 4 cm 3 4 and 2 4 cm  5 6 cm 3 2 and 2 4 cm   BBI 8583463 Angle rotor made of polypropylene  12 x 1 5  2 2 ml  for reaction 14 800 15 183  vials e g  no  15008  15
107. timmungen sachgem     dekontaminiert und  gereinigt  Von den Ger  ten gehen keinerlei chemische  biologische oder radioaktive Risiken aus  die eine Gef  hrdung f  r die  Sicherheit oder die Gesundheit betroffener Personen darstellt        Firma   Institut       Adresse   Land  Tel    Fax          Name der autorisierten Person       Position       Datum   Unterschrift                   D  Grund der R  cksendung    U Falschlieferung LJ  Umtausch U Reparatur QO  Umbau U Entsorgung U Sonstiges             E  Beschreibung der Fehlfunktion  bei Reparatur  und oder Beschreibung der auszuf  hrenden Arbeiten          112 Erkl  rung   ber die Dekontaminierung       F 13 01 Seite  3 3  Version  01 G  ltig ab  01 01 2008    sartorius    biotech          F  Vom Sartorius Servicezentrum auszuf  llen    Bemerkungen             Bitte verpacken Sie das Ger  t sachgem     und senden Sie es  frei Empf  nger an Ihren zust  ndigen lokalen Service oder  direkt an Sartorius Stedim Biotech GmbH       Sartorius Stedim Biotech GmbH  Servicezentrum Biotechnologie  August Spindler Stra  e 11  37079 G  ttingen   Telefon  49 551 308 1300   Fax  49 551 308 1293          Erkl  rung   ber die Dekontaminierung    113    Sartorius Stedim Biotech GmbH  August Spindler Str  11  37079 Goettingen  Germany    Phone  49 551 308 0  Fax  49 551 308 3289  www sartorius stedim com    Copyright by   Sartorius Stedim Biotech GmbH   Goettingen  Germany    All rights reserved  No part of   this publication may be reprinted 
108. tion  iliius   6 5 1 Unterbrechen einer Zentrifugation              6 5 2 Unterbrechen eines Bremsvorgangs             6 5 3 Drehzahl   Relative Zentrifugal   beschleunigung  RZB                             6 5 3 1   ndern des Drehzahl     RZB Wertes w  hrend des Laufs         6 5 4  Laufzeit    ecce t mm  6 5 4 1   ndern der Laufzeit w  hrend  des Laufs   eet rue  6 5 4 2 Kurzzetbetrieh    6 5 4 3 Dauerbetrieb                            6 5 5 Softstart  und Softstop Funktionen       6 5 6 Rotorauswahl           nauaanaunanaanaaa  6 6  Ausschalten ege eet SN AE ken    7  St  rungen und Fehlersuche                               7 1 Allgemeine St  rungen 2    cece ee eee es  7 1 1 Notentriegelung      eee eee   7 2 Tabelle der Fehlermeldungen                             Inhalt    59       8     9     60    Wartung und Instandhaltung                            89  8 1 Wartungsarbeten  000  c cece eee eee 89  8 1 1 Zentrifuge e pr sisse 89  8 1 2  Z  behOF Saisie See idee pedes 89  8 1 2 1 Kunststoffzubeh  r                     90  8 1 3  ROTM eren SE St 90  8 1 4 Mikroh  matokritteller                          90  8 1 5  GlasbDt  chi  s ir are 91  8 2 Sterilisation und Desinfektion von Rotorkammer  und Zubeh  r    seen Sat 91  8 2 1 Autoklavieren 2 00 cece cence eee 91  8 3 Instandhaltungsarbeiten            nasaaeinaaan 92  8 4 R  cksendung defekter Tele    93  8 5 Wartung EE 93  Entsorgung  ceriose nte a b beds 94  Centrisart   A 14    10    bersicht 7 coders es iet A Zeene de
109. tion Run is closed         Press the Start   Stop key in order to start a centrifugation run     6 5 1 Interrupting a     Press the Start   Stop key in order to interrupt a centrifugation run   Centrifugation Run The centrifugation run will be terminated prematurely     6 5 2 Interrupting a     Press the Start   Stop key during a deceleration process in order to interrupt it and  Deceleration Process to restart the centrifuge     26 Operation       6 5 3 Speed   Relative  Centrifugal Force  RCF     6 5 3 1 Changing the  Speed   RCF value during  centrifugation    6 5 4 Runtime    6 5 4 1 Changing the  Runtime during  Centrifugation    The RCF value is determined by the rotor geometry and speed    The RCF and speed values  therefore  depend on each other  If one of the two values   is entered  the other value will be set automatically        To enter a value  press the Select key repeatedly until the corresponding unit  flashes on the display        Select the desired speed or RCF value via the arrow keys      Confirm the selection by pressing the Start key     The data will also be accepted and saved after approx  20 seconds if no other key is  pressed within this time period     During operation  you can switch from the speed value to the RCF value and vice  versa via the arrow keys     The preselected speed or RCF value can be changed during centrifugation        Press the select key repeatedly until the desired unit flashes on the display        Change the speed or RCF val
110. tive clothing is not required for the operation of the centrifuge   The materials to be centrifuged may  however  require special safety measures   e g  centrifugation of infectious  toxic  radioactive or pathogenic substances            3 6 5 Safety Instructions for For safe operation  observe the following before starting the centrifuge   Centrifugation         Ensure that the centrifuge was set up and connected properly   see  gt  chapter 5    Set up and Connection        Maintain a safety distance of at least 30 cm  12 inches  around the  centrifuge      Do not store any dangerous goods in the centrifuge area      Do not stay in the safety area longer than what is absolutely necessary for the  operation of the centrifuge      Only use the centrifuge with rotors and accessories that have been approved  by the manufacturer  We explicitly warn against the use of equipment of poor  quality  Breaking glass or bursting vessels can cause dangerous imbalances at  high speeds      Ensure that rotor and buckets are correctly fitted  see  gt  chapter 6 2 2 1   Installation of the Rotor        Observe the instructions on the installation of accessories  see  gt  chapter  6 2 2 3  Installation of Accessories        The rotor must be loaded symmetrically at equal weights      If liquids with a density  gt  1 2 g cm  are used  reduce the speed  see  gt  chapter  2 2 2 2  Density        Do not use the centrifuge if the rotor is loaded asymmetrically      Do not use the centrifuge with tu
111. toxischen    radioaktiven oder pathogenen Substanzen            3 6 5 Sicherheitshinweise Die nachfolgenden Hinweise sind vor jeder Zentrifugation zu beachten   zur Zentrifugation         berpr  fen  siehe  gt  Kapitel 5    Aufstellung und Anschluss     WARNUNG     Grunds  tzlich einen Sicherheitsbereich von mindestens 30 cm um  die Zentrifuge freihalten      Niemals Gefahrenstoffe jeglicher Art im Sicherheitsbereich der Zentrifuge  lagern      Nicht langer als f  r den Betrieb notwendig im Sicherheitsbereich der  Zentrifuge aufhalten      Nur vom Hersteller zugelassene Rotoren und Zubeh  rteile verwenden   Keine minderwertige Handelsware benutzen  Glasbruch oder platzende  Gef    e erzeugen bei hoher Drehzahl gef  hrliche Unwucht      Korrekten Sitz des Rotors und der Becher   berpr  fen  siehe  gt  Kapitel  6 2 2 1    Einsetzen des Rotors        Hinweise zum Einsetzen von Zubeh  r beachten  siehe  gt  Kapitel  6 2 2 3    Einsetzen von Zubeh  r        Der Rotor muss symmetrisch und gewichtsgleich beladen sein      Drehzahl reduzieren  wenn Fl  ssigkeiten mit einer Dichte  gt  1 2 g cm  einge   setzt werden  siehe  gt  Kapitel 2 2 2 2  Dichte        Der Betrieb der Zentrifuge mit asymmetrisch beladenem Rotor ist verboten      Der Betrieb der Zentrifuge mit zu langen GefaBen ist verboten     N   Ordnungsgem    e Aufstellung und korrekten Anschluss der Zentrifuge       Sicherheit 71       3 6 6 Bestandigkeit von Chemische Einwirkungen beeinflussen stark die Polymerkette von Kun
112. trieben werden   Die gesamte zugef  hrte Energie der Zentrifuge wird in W  rme umgewandelt und an  die Umgebungsluft abgegeben      F  r ausreichende Bel  ftung sorgen      Einen Sicherheitsabstand von mindestens 30 cm um die Zentrifuge einhalten   damit die in der Maschine befindlichen L  ftungs  ffnungen in vollem Querschnitt  wirksam bleiben      Zentrifuge keinen thermischen Belastungen z B  durch W  rmeerzeuger aussetzen      Direkte Sonneneinstrahlung  UV Strahlung  vermeiden      Der Tisch muss standfest sein und   ber eine stabile  ebene Tischplatte verf  gen        ACHTUNG     Bei Transport aus kalter in w  rmere Umgebung bildet sich Kondenswasser  in der Zentrifuge  Die Zentrifuge muss vollst  ndig getrocknet sein  mind  24 h    bevor sie wieder in Betrieb genommen wird              A    WARNUNG        Die auf dem Typenschild angegebene Betriebsspannung muss mit der   rtlichen  Versorgungsspannung   bereinstimmen          Sartorius Mikrozentrifugen sind Ger  te der Schutzklasse    Die Ger  te der  Baureihe 1 14 haben eine dreiadrige Netzanschlussleitung mit Kaltger  testecker     Die Zentrifuge muss bauseits typisch mit jeweils 16 Amp L oder B abgesichert  werden     Aufstellung und Anschluss 75       6 1 Erste Inbetriebnahme    6 2 Einschalten    6 2 1   ffnen und Schlie  en  des Deckels    6 2 2 Einsetzen von Rotoren  und Zubeh  r    6 2 2 1 Einsetzen des Rotors    76 Betrieb    6  Betrieb       A    VORSICHT     Vor der ersten Inbetriebnahme ist daf  r zu sorgen 
113. ture         This operating manual is a part of the product      The operating manual must be kept at the location of use of the centrifuge   Ensure that it is accessible at all times        The operating manual must be handed over to any subsequent owner or operator  of the centrifuge      Any changes made must be added to the operating manual       n addition to the operating manual  the general and local rules and regulations  concerning the prevention of accidents and the protection of the environment  must also be supplied        Safety and danger indications on the centrifuge must be kept readable at all  times  If necessary  they must be replaced     Safety 13       3 6 Safety Instructions    3 6 1 Electrical Safety To reduce the risk of electrical shock  the centrifuge uses a three wire electrical cord  and plug to connect the equipment to earth ground  To preserve this safety feature                   Ensure that the wall socket is properly wired and grounded    A   Check that the mains voltage agrees with the nominal voltage listed on the  WARNING  name plate      Do not place vessels containing liquid on the centrifuge lid or within the  safety distance of 30 cm around the centrifuge  Spilled liquids may get into  the centrifuge and damage electrical or mechanical components      Work on the power supply system must only be performed by certified  electricians      Inspect the electrical equipment of the unit regularly  Defects such as loose or  burnt cables must b
114. u halten und ggf  zu erneuern     Sicherheit 69       3 6 Sicherheitshinweise    3 6 1 Elektrische Sicherheit Zum Schutz vor Stromschl  gen ist die Zentrifuge mit einem geerdeten Netzkabel  und Netzstecker ausgestattet  Um die Wirksamkeit dieser Sicherheitsfunktion zu  gew  hrleisten  sind folgende Punkte zu beachten          Sicherstellen  dass die entsprechende Wandsteckdose korrekt  angeschlossen ist   WARNUNG     Die Netzspannung muss mit der Spannung   bereinstimmen  die auf dem    Typenschild der Zentrifuge angegeben ist      Keine Gef  De mit Fl  ssigkeit auf den Zentrifugendeckel oder in den Sicher   heitsabstand von 30 cm stellen  Versch  ttete Fl  ssigkeiten k  nnen in das  Ger  t eindringen und elektrische oder mechanische Bauteile besch  digen      Arbeiten an der elektrischen Versorgung nur von einer Elektrofachkraft  durchf  hren lassen      Die elektrische Ausr  stung des Ger  ts regelm    ig   berpr  fen  M  ngel wie  lose Verbindungen bzw  angeschmorte Kabel m  ssen sofort beseitigt werden        3 6 2 Mechanische Sicherheit Um einen sicheren Betrieb der Zentrifuge zu gew  hrleisten  sind folgende  Ma  nahmen einzuhalten          Auf keinen Fall bei laufendem Rotor den Deckel   ffnen      Niemals bei laufendem Rotor in den Rotorraum greifen    WARNUNG     Den Betrieb der nicht fachgerecht installierten Zentrifuge unterlassen      Zentrifuge niemals mit abgenommener Verkleidung betreiben      Zentrifuge niemals mit Rotoren und Eins  tzen betreiben  die Korrosi
115. uding accessories and  batteries  does not belong in the household waste  but rather should be recycled as  electrical and electronic equipment  For disposal or recycling  please contact our  service staff on site  In addition  the partners listed on the following website are  available within the EU     1  Select http   www sartorius com    2  Select the  Services  tab    3  Then select    Disposal Information     4  Addresses for the local Sartorius disposal contacts can be found in the PDF files  available for download on this page        Sartorius will not take back equipment contaminated with hazardous materials   ABC contamination    either for repair or disposal        Detailed information  including service addresses for returning your device for repair  or disposal  can be found on our website  www sartorius com  or requested from a  Sartorius Service Center        10 1 Technical Data    10 1 1 Ambient Conditions    10  Overview       Manufacturer    Sartorius Stedim Biotech GmbH  37079 Goettingen  Germany       Type designation    CENTRISART  A 14       Electrical connection   Protection class     See name plate          IP Code  according to DIN EN 60529  20  Connected load  kVA  0 157  Power consumption  kW  0 095    Max  current consumption  A     0 68  at 220   240 V  50   60 Hz  or  1 5  at 100  120 V  50   60 Hz        Performance data   Max  speed  min     Min  speed  min     Max  capacity  ml    Max  gravitational field  x g   Min  gravitational field  x g  
116. ue by pressing the arrow keys  Thep arameters will  take effect immediately  The preselected total runtime is displayed in the middle  line of the display     In the middle line of the display the preselected total running time is displayed    During centrifugation  the remaining runtime is displayed  The runtime of the   centrifuge can be set at one second intervals up to 99 minutes and 59 seconds        To select a runtime  press the select key repeatedly until the time unit flashes on  the display        Select the desired runtime by pressing the arrow keys      Confirm the selection by pressing the start key     The data will also be accepted and saved after approx  20 seconds if noother key is  pressed within this time period     The preselected runtime can be changed during centrifugation        Press the select key repeatedly until the time unit flashes on the display        Change the desired run time by pressing the arrow keys  The parameters will be  accepted immediately           If the centrifugation time is changed during the run  the centrifuge will run for  the entire new time and will disregard the previous runtime that has already  elapsed        Operation 27       6 5 4 2 Short Run    6 5 4 3 Continuous Run    6 5 5 Softstart and Softstop    Function    28    Operation    During the short run  the centrifuge accelerates at maximum power until the  maximum speed is reached       Press and hold the Start   Stop key for the duration of the short run     The mes
117. view            0 0     10 1 Technical Data   10 1 1 Ambient Conditions                        10 2 Formulas   Mathematical Relation                10 2 1 Relative Centrifugal Force  RCF            10 2 2  Density  ioi RESET Seer REST iS  10 2 3 Speed Gravitational Field Diagram        10 3 Troubleshooting           csse  10 3 1 Centrifuge Cannot Be Started               10 3 2 Centrifuge Decelerates during    10 4 1 Table of Error Codes                       10 5 Accessories Suitable for CENTRISART    A 14        10 6 Rotor Radii                    2  2cocceccneecnnen   10 7 Declaration of Decontamination   Return Form     10 8 Speed Gravitational Field Diagram                 10 9 Rotors and Accessories with a Different  Service Die   10 10 Resistance Data     Statement of Confommitv         e    NRTL Certificate    11  MdeX EE    12  Declaration of Decontamination                             Special Notes    This manual on the micro centrifuge CENTRISART  A 14 describes the product at the  time of printing stated in the revision number  All data has been compiled with care   although no guarantee can be given for the data provided  Sartorius Stedim Biotech  GmbH reserves the right to make technical changes to the design and equipment of   its products or to make changes to the associated documentation without any prior   notice or specific mention     Because Sartorius  devices are constantly undergoing further development  some  components and their operation may not be d
118. wicklung der   R  cksendung  Werden mehrere Teile in einem Paket zur  ckgeschickt    sollte zu jedem defekten Teil eine separate Fehlerbeschreibung beigef  gt werden      Eine ausf  hrliche Fehlerbeschreibung ist notwendig  um die Reparatur z  gig  und wirtschaftlich durchzuf  hren        Erfolgt keine Beschreibung der Fehlfunktion auf dem Formular  ist eine R  ck   verg  tung bzw  Gutschrift nicht m  glich  In diesem Fall behalten wir uns vor   die Teile zu unserer Entlastung kostenpflichtig zur  ckzusenden          Vermerken Sie auf diesem Formular unbedingt in dem vorgegebenen Feld  wenn  ein Kostenvoranschlag gew  nscht wird  Kostenvoranschl  ge werden nur auf  ausdr  cklichen Wunsch und gegen Berechnung erstellt  Bei Auftragserteilung  werden die Kosten verrechnet     Die Mikrozentrifuge CENTRISART  A 14 muss nicht gewartet werden  Falls das Ger  t   nicht startet bzw  bei Funktionsst  rungen k  nnen Sie wie folgt vorgehen     Pr  fen Sie die Spannungsversorgung        berpr  fen Sie die vorgenommenen Einstellungen und ob der Deckel korrekt  geschlossen ist        Die Mikrozentrifuge CENTRISART  A 14 kann bei ge  ffnetem Deckel  nicht gestartet werden            Falls alle Einstellungen richtig sind  kein Bedienungsfehler vorliegt und das  Ger  t noch immer nicht ordnungsgem     funktioniert  setzen Sie sich mit dem f  r  Sie zust  ndigen Service der Sartorius Stedim Biotech GmbH in Verbindung     Wartung und Instandhaltung 93       94    Entsorgung    9  Entsorgung    D
119. y     cece cece  6 4 1 4 Set Arrow Keys   6 4 2 Display     6 5 Starting a Centrifugation Run                         6 5 1 Interrupting a Centrifugation Run              6 5 2 Interrupting a Deceleration Process             6 5 3 Speed   Relative Centrifugal Force  RCP          6 5 3 1 Changing the Speed   RCF Value  during Centrifugation                   6 54 Runtime 2220205  sce 2   6 5 4 1 Changing the Runtime during  Centrifugation                    0005   6 5 4 2 Short Run          0    eee  6 5 4 3 Continuous Run   6 5 5 Softstart and Softstop Function          6 5 6 Rotor Selection                 222220     6 6 Switching off the System       7  Malfunctions and Error Correction                       7 1 General Malfunctions                                  7 1 1 Emergency Lid Release      7 2 Table of Error Code     Contents         Maintenance and Service    33    8 1 Maintenance    een 33  8 1 1 Centrifuge     iiis 33  8 1 2 ACCESSOMMES u    senden dan 33   8 1 2 1 Plastic Accessories                      34  Of We 34  8 1 4 Microhaematocrit Rotor                        34  8 1 5 Glass Breakage               2  e cence eee ees 35   8 2 Sterilization and Disinfection of the Rotor  Chamber and Accessories eee ee 35  8 2 1 Autoclaving  cece eee e eee tees 35   Se HDS ol    en dU ER Denuo n enis 36   8 4 Return of Defective Parts                             37   8 5  Maintenanee    e epos aa 37   e Disp  sal irr e Hr epe ER LED das 38    Centrisart   A 14    10  Over
120. y defective part        A detailed problem description is necessary in order to perform the repair quickly  and economically        If the form does not include a description of the malfunction  neither are fund  nor a credit note can be issued  In this case  we reserve the right to return the  parts to you at your expense            Please note on the form if you would like to receive a cost estimate  Cost  estimates are only prepared upon request and against charge  If an order is placed   these charges will be offset     The CENTRISART   A 14 micro centrifuge does not require maintenance  If the unit  does not start or in case of malfunctions you can proceed as follows        Check the power supply        Check the settings and whether the lid is properly closed        The CENTRISART   A 14 micro centrifuge cannot start with the lid open            Ifall settings are correct  there are no operational errors and the machine is still  not operating properly  contact the responsible Sartorius Stedim Biotech GmbH  service staff     Maintenance and Service 37       38    Disposal    9  Disposal    The packaging consists of environmentally friendly materials that can be used as  secondary raw materials  Packaging that is no longer needed can be disposed of in  Germany free of charge via the VfW Dual System  contract number D 59101 2009   1129   Otherwise  you dispose of the material at the local waste management facility  according to the applicable regulations  The device  incl
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Gigaset A490/A495    BACOU SOLANUM S1P SRC  Microlife A6 Navigation Manual  LPC2 C05 User Manual  TP600, TP650  OLAT 6 User Manual v1.0 (2008)  Oracle Integrated Lights Out Manager 3.0 Supplement for the Sun  FLEX-6000 Signature Serie SmartSDR Software  Important Safety Instructions    Copyright © All rights reserved. 
   Failed to retrieve file