1. File functions Sensor functions Data representation 1 1 open file 2 1 connect USB measuring adapter 3 1 create new diagram 1 2 save file 2 2 start new recording Further functions 4 1 interface configuration 4 2 program information 1 3 print file 2 3 stop recording 5 3 Data Recording 5 3 1 Connecting the USB Adapter e connect the USB measuring adapter to the USB Port e click in the menu item USB measuring adapter on Connect or on the associated icon in the toolbar e USBsoft2500 is now searching for connected measuring devices e The located measuring adapter will be shown like this Connect USB measuring adapter M CPA 2500 48000005 New Search Cancel If there was no device found you have to click on New Search The USB port will be initialised and attached devices will be located Should still no measuring adapter be found please check the following points again e Is the USB measuring adapter connected to the USB port e Was the correct interface chosen Configuration Interface The marked measuring adapter will be opened by OK WIKA Operating Instructions model CPT2500 8 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 5 3 2 Sensor Data Screen register data register Comment register instrument register extras PA 2500 48040005 gt Jol x CRA 2500 45002005 VI Instrument Data Comment Extras measu
2. 2 General handling instructions 2 1 Operation mode The measurement is started by a trigger condition Then the device automatically gives back the meas ured values in the adjusted cycle time without any request until the stop condition is fulfilled For the communication and configuration of the device the software USBSoft2500 is necessary Adjustable parameters are among other ones Cycle time Ims 10sec programmable in steps of ms Measured values cycle time lt 5 ms itis possible to choose the values to be recorded measurand min peak max peak cycle time gt 5 ms acomplete data set is always recorded containing the following values actual pressure at the moment of the data transfer minimum pressure min peak in the period of the last cycle time maximum pressure max peak in the period of the last cycle time average value of the pressure in the period of the last cycle time Trigger conditions 5 for the measuring start 6 for the measuring stop Pre trigger 50 data sets at a cycle time of gt 5ms respectively 200 measurands cycle time lt 5 ms 2 2 To connect change sensors Only pressure sensor model CPT2500 are allowed to be used If other sensors are used the adapter and the sensor may be destroyed To change the sensor you have to disconnect the adapter Sensors have to be connected before acti vating the adapter Otherwise they are not found by the adapter correctly During the connecting i
3. Der Hersteller bernimmt keinerlei Haftung f r Sch den die an ihren angeschlossenen Ger ten durch den Einsatz des Schnittstellenadapters verursacht werden 7 Beachten Sie die blichen Vorschriften und Sicherheitsbestimmungen f r Elektro Schwach und Starkstromanlagen insbesondere die landes blichen Sicherheitsbestimmungen z B VDE 0100 8 Konzipieren Sie die Beschaltung besonders sorgf ltig beim Anschluss an andere Ger te z B PC Unter Umst nden k nnen interne Verbindungen in Fremdger ten z B Verbindung GND mit Schutzerde zu nicht erlaubten Spannungspotenzialen f hren 9 Wenn anzunehmen ist dass das Ger t nicht mehr gefahrlos betrieben werden kann so ist es au er Betrieb zu setzen und vor einer weiteren Inbetriebnahme durch Kennzeichnung zu sichern Die Sicherheit des Benutzers kann durch das Ger t beeintr chtigt sein wenn es zum Beispiel sichtbare Sch den aufweist nicht mehr wie vorgeschrieben arbeitet l ngere Zeit unter ungeeigneten Bedingungen gelagert wurde In Zweifelsf llen sollte das Ger t grunds tzlich an den Hersteller zur Reparatur Wartung einge schickt werden 10 Achtung Dieses Ger t ist nicht f r Sicherheitsanwendungen Not Aus Vorrichtungen oder An wendungen bei denen eine Fehlfunktion Verletzungen und materiellen Schaden hervor rufen k nnte geeignet Wird dieser Hinweis nicht beachtet k nnten schwere gesund heitliche und materielle Sch den auftreten 0O P W PO 1 4
4. 22 Sensoren ansliecken Wechseln zz aaa a nern 19 2 3 Nullpunktkorrektur des Drucksensor OEFES Benno nenn nano nenn enenn nenne nenn nnnenennn 19 2 4 Steigungskorrektur des Drucksensor GCAU nenne nenne nenne nenne nenne nenn 19 2 5 Druckanschluss an die Druckesensoren 0 ccc eccececcececeeeeeeseeaeeueauaueeeauaueueauausueavaueeeavaueueauauees 20 2 6 Hinweis ZUM bhalbrterserice ccc ecccc ccc cceceseeeecuaeeecuuaueesuaueeeuaueusuaueusauaueesauaueeeauaueeeavaueenes 20 3 TREIBER INSTALLA TION rss aaa ea TE En 20 3 1 Windows 2000 Windows XP und Windows Vista bzw Windows 7 sanceres 20 4 H UFIG GESTELLTE FRAGEN EAO EEN 20 4 1 Wie kann ich berpr fen ob der Adapter korrekt installiert wurde und unter welchem COM Port kann ich den neu installierten Adapter nun ansprechen u2240024000enn nenn nenne nenn nennen 20 4 2 Wie kann ich den COM Port des Adapters ndern nenne nenne nenne nennen 20 4 3 Wird ein lterer bereits im System vorhandener Treiber automatisch aktualisiert 21 4 4 Wie kann ich die verwendete Treiberversion feststellen nennen nennen nennen 21 4 5 Wie kann ich eine ltere Treiberversion aktualisieren bzw deinstallieren 21 5 DIE SOFTWARE USBSOFT2500 nn ae 22 5 1 Installation der Software E 22 52 IBCOIENGIEMICN ILC aie aie e AE e E Ae 22 BEL OI EE 22 92 2 WWEIKZCUGICIS ee ee ee ee DEE ee Ee dh te 22 e WER EE e le le E 23 63 1
5. 5 3 3 Aufzeichnung starten Durch einen Aufzeichnungs Neustart werden alle bisher aufgezeichneten Da D ten berschrieben Gegebenenfalls die Daten vorher sichern oder bei Neustart nach Aufforde rung abspeichern WIKA Betriebsanleitung Druckmessumformer 23 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft Iw CPA 2500 48000005 Ausgabe Messer IV min Peak Zykluszeit E ms Ds Start 8 Startsignal 7 r Startbedingung Bore Ce Messwert f sofort Ge Start wenn Messwert gt Schwelle 1 Schwelle 1 100 Mittelwert Start wenn Messwert lt Schwelle 2 C Start wenn Messwert gt Schwelle 1 oder Messwert lt Schwelle 2 e i min max Peak C Start wenn Messwert lt Schwelle 1 und Messwert gt Schwelle 2 stopp m Stoppsignal r Stoppbedingung manuell Ce Messwert C Stopp nach lo Sekunden Mittelwert C Stopp wenn Messwert gt Schwelle 3 min max Peak e Stopp wenn Messwert lt Schwelle 4 C Stopp wenn Messwert gt Schwelle 3 oder Messwert lt Schwelle 4 Schwelle 4 35 C Stopp wenn Messwert lt Schwelle 3 und Messwert gt Schwelle 4 Starten Stoppverzogerung 0 Sekunden Abbrechen i Zum Starten einer neuen Aufzeichnung w hlen Sie bitte Neue Aufzeichnung starten oder das entsprechende Symbol in der Werkzeugleiste Sie k nnen nun aus einer Auswahl an Start und Stoppbedingungen ausw hlen und die Ausgabedaten festlegen Einstellun
6. Um einen Treiber zu aktualisieren muss der alte Treiber zuerst deinstalliert und anschlie end der neue Treiber installiert werden 1 Deinstallation des Treibers Stecken Sie den USB Adapter nicht an Rufen Sie unter Start Einstellungen Systemsteuerung den Punkt Software auf Suchen Sie in der Programmliste den Eintrag CP210X USB to UART Bridge Controller und dr cken Sie auf ndern Entfernen Best tigen Sie den Warnhinweis zur Deinstallation Die Deinstallation wird nun durchgef hrt Die entsprechende Erfolgsmeldung ist anschlie end zu quit tieren Der Treiber ist somit f r alle entsprechenden USB Adapter deinstalliert 2 Neuinstallation des Treibers Die Neuinstallation erfolgt entsprechend der Installationsanweisung Lesen Sie bitte dort bei Ihrem Be triebssystem weiter WIKA Betriebsanleitung Druckmessumformer 21 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 5 Die Software USBsoft2500 Die Software USBsoft2500 erm glicht die Bedienung eines Druckmessumformers CPT2500 der mit einem USB Adapter CPA2500 an einen PC angeschlossen ist Mit der Software ist es m glich Aufzeichnungen zu starten zu stoppen einzulesen und darzustellen Zur Visualisierung und besseren bersicht k nnen die aufgenommenen Messwerte in Diagrammen dargestellt werden 5 1 Installation der Software Windows starten CD ROM in das CD ROM Laufwerk einlegen Ausf hren im Start Men
7. WIKA Betriebsanleitung Druckmessumformer 22 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 5 3 Datenaufzeichnung 5 3 1 USB Adapter verbinden e USB Adapter an USB Port anschlie en e Unter dem Men punkt USB Messadapter auf Verbinden oder auf das zugeh rige Icon in der Werkzeugleiste klicken e USBsoft2500 sucht nun nach verbundenen Druckmessumformern e Der gefundene Messadapter wird wie folgt angezeigt USB Messadapter verbinden Iv CPA 2500 48000005 Neue Suche _abbrechen Falls kein Gerat gefunden wurde klicken Sie auf Neue Suche Der USB Port wird initialisiert und angeschlossene Gerate erkannt Sollte dennoch kein Messadapter gefunden werden berpr fen Sie bitte nochmals folgende Punkte e Ist der USB Adapter am USB Port angeschlossen e Wurde die richtige Schnittstelle ausgew hlt Konfiguration Schnittstelle Mit Ok wird der markierte Messadapter ge ffnet 5 3 2 Sensor Datenfenster Register Daten Register Kommentar Register Ger t Register Extras PP Daten der Messkan le Mittelwert Druck rel Mirimaldruck rel 4 Maximaldruck rel 370 mbar 371 mbar Aktueller Zustand der Auf zeichnung Stoppbedingung Stopp wenn Messwert lt 95 mbar S Datensat Anzahl der Datens tze atensdtze 380 em und Zeitraum der Auf 05 07 2007 15 58 59 05 07 2007 15 53 01 zeichnung
8. w hlen Geben Sie D setup ein wobei D f r den Laufwerksbuchstaben Ihres CD ROM Laufwerkes steht und bet tigen Sie die Eingabetaste Ist Ihr CD ROM Laufwerk nicht D m ssen Sie den entspr Laufwerksbuchstaben im Aufruf verwenden e Folgen Sie den Anweisungen des Installationsprogramms e Es wird eine neue Programmgruppe mit folgendem Programmsymbol angelegt Mit einem Doppelklick auf dieses Symbol k nnen Sie die Software starten e Programm starten w hlen Sie die gew nschte Sprache und die Schnittstelle aus an die Sie Ihren Schnittstellenadapter angeschlossen haben 5 2 Bedienelemente 5 2 1 Men leiste ber die Men leiste sind s mtliche Programmfunktionen zug nglich Der Inhalt der Men leiste ist abh ngig vom Programmzustand Datei USE Messadapter Diagramm Konfiguration Fenster Info 5 2 2 Werkzeugleiste F r die komfortable Bedienung der Software sind die wichtigsten Funktionen der Software in der Werk zeugleiste zusammengefasst Wenn der Mauszeiger ber ein Symbol bewegt wird erscheint nach kur zer Zeit eine Funktionsbeschreibung Der Inhalt der Werkzeugleiste ist abh ngig vom Programmzustand co Gel Gel mini Zi Dateifunktionen Sensorfunktionen Datendarstellung 1 1 Datei ffnen 2 1 USB Adapter verbinden 3 1 Neues Diagramm erstellen 1 2 Datei speichern 2 2 Neue Aufzeichnung starten oe 1 3 Datei drucken 2 3 Aufzeichnung stoppen Sonstige 4 1 Schnittstelle auswahlen 4 2 Info
9. 3 7 Extras Dieses Register erm glicht einige Voreinstellungen f r Bun mbar E die Aufzeichnung Offset 0 mbar Unter dem Men punkt Einheit kann die Aufzeichnungs a om einheit des Messumformers eingestellt werden a e Mit Offset und Scale k nnen Nullpunkt und Spanne Falls erforderlich korrigiert werden Mit dem Tiefpassfilter k nnen bei Bedarf Druckspitzen ausgeblendet werden WIKA Betriebsanleitung Druckmessumformer 25 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 5 4 Arbeiten mit Dateien Wenn Sie geladene Daten mit Speichern oder Speichern unter im Men Datei abgespeichert ha ben k nnen Sie diese zu einem beliebigen Zeitpunkt wieder in das Programm laden um die Daten zu betrachten auszuwerten Dazu mit Datei Offnen die entsprechende Datei ffnen 5 4 1 Dateien exportieren Die Dateien k nnen als ASCII Text File gespeichert werden um sie z B mit einer Textverarbeitung oder in einer Tabellenkalkulation betrachten zu k nnen W hlen Sie dazu das gew nschte Datenfens ter aus und w hlen Sie Datei Export aus dem Men Achten Sie insbesondere bei Tabellenkalku lationen darauf im folgenden Dialogfenster Datei exportieren die richtigen Einstellungen zu machen 5 4 2 Daten in die Zwischenablage kopieren Daten in Tabellenform k nnen in die Zwischenablage kopiert werden um in anderen Anwendungen wieder eingef gt zu werden D
10. 4 Einzelmesswerten aufge zeichnet 50 Datens tze x 4 Messwerte 200 Messwerte Beispiel Es sei eine Zykluszeit von 10 ms eingestellt Es werden also ber einen Zeitraum von 500 ms 10 ms x 50 Datens tze Messdaten vor der eigentli chen Wertaufnahme festgehalten WIKA Betriebsanleitung Druckmessumformer 24 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft Stopp Hier k nnen Sie in Analogie zu den Startbedingungen die Stoppbedingungen festlegen Neben dem manuellen Stopp und dem Messungsstopp nach einer festgelegten Zeit steht Ihnen auch der Stopp durch bestimmte Schwellwerte zur Verfugung werden diese unter oder uberschritten ist die Bedingung je nach gew hltem Fall erf llt Die Eingabe der Schwellwerte erfolgt in der Maske auf der rechten Seite Sie k nnen auch w hlen welches Stoppsignal zum Messungsstopp f hren soll Dies ist allerdings nur m glich wenn die Zykluszeit gt 5 ms betr gt Diese Eingabe k nnen Sie auf der linken Seite unter Stoppsignal vornehmen Die Stoppverz gerung bewirkt eine weiterlaufende Messwertaufnahme bis die eingegebene Zeit ab gelaufen ist Danach wird die Messung automatisch gestoppt 5 3 4 Auslesen der Messwerte Um die Messwerte lesen zu k nnen muss die zyklische Aufzeichnung zun chst gestoppt werden Nach dem Laden der Daten werden diese im Register Daten automatisch angezeigt Die wei hinterlegten Felder f r die Tabellen berschriften k nnen v
11. 40 27 08 2007 Scrollbar if a _GDUSE 1007 36000007 1 Relative Pressure mbar DINE 1000 36000007 4 Relative Pressure Max mba zooming action 4 has been carried 27 022007 1436414000 150 amp mb4 GDUSE 1000 2000007 4 Relative Pressure Max mbail out the scrollbar can be used to go through the diagram Legend if activated a description of the graph will be displayed Cursor if activated a crosshair cursor will be displayed to show the individual measuring points The measuring point data will be displayed in the status bar WIKA Operating Instructions model CPT2500 12 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 5 6 1 Adding Data Labels To add a comment to a specific measuring point select menu item Diagram Add Data Label or click on the corresponding symbol By moving the mouse over the diagram the Er mbol will appear as mouse pointer A text line which can be filled in freely will be placed at the position desired by a mouse click 5 6 2 Adding Series To be able to display additional measuring series in a diagram select the menu item Diagram Add series or click on the corresponding symbol of the diagram window The data source selection will ap pear again and you can select additional measuring series 5 6 3 Zoom function If 2 units are displayed use the amp and amp symbols to select the Y axis desired Place the mouse at the beginning of the desi
12. mbar bar usw pro Diagramm max 15 Kurven pro Einheit Y Achse Darstellung der Einheit Zoom linke rechte Y Achse W hlen Sie ob sich die Maus Zoomfunktion auf die linke oder rechte Y Achse auswirken soll Datenbeschriftungen hinzuf gen entfernen Messpunkte k nnen be schriftet werden s u Zoom zur ck Die letzte Diagramm umbenennen Das Dia Zoom Aktion r ckg ngig gramm hier Diagramm 1 kann hier machen umbenannt werden ia Diagram ni Vis 2 9 E Einstellungen 1100 5 Messreihen hinzu manuelles f gen entfernen Zoomen Gitter die Zahl der darge und Farbein stellten Kurven kann stellungen Zar ver ndert werden 3004 Wis Mi s u Zoom alles Maximal dar stellbarer Bereich GL Messpunkte zeigen Messpunkte k nnen 10 44 10 10 44 20 10 4430 1044 40 1042 50 1045 00 pp 10 45 20 gezeigt markiert 13 03 2007 werden Rollbalken wur a busgii 8000002 1 Druck abs mbar de eine Zoom Aktion ausgef hrt REISE HEET EE 003 1 Druck abs mban kann man mit den Po Rollbalken im Cursor falls aktiviert wird ein Fadenkreuz gezeigt mit dem ein Diagram wan zelne Messpunkte gezeigt werden k nnen Die Messpunkt Daten werden in der Statuszeile anaezeiat Legende falls aktiviert wird eine Beschreibung der Kur ven anaezeidt dern 5 6 1 Datenbeschriftungen hinzuf gen Um einzelne M
13. program is operational within the keeping of the program description As it is not possible at the present state of the art to produce computer programs in such a way that they work without faults in all applications and combinations WIKA shall not assume any liability for faultlessness and the uninterrupted operation of the program No guarantee shall be given in particular for the fact that the program meets the requirements of the user or for the fact that the program operates together with the program selected The responsibility for the correct selection and the consequences of the use of the program as well as for the results intended or obtained shall be borne by the buyer registered user WIKA shall not be liable for any damage expect for damage which has been caused by gross negli gence on the side of WIKA In this case WIKA shall assume liability for direct injury or property damage up to ten times the purchase price for each event of damage WIKA shall not be held liable for any damage other than the said rendered above The liability for gross negligence shall be excluded vis a vis merchants This contract shall be in force until the registered user terminates it by destroying the program inclusive of all copies In addition the contract shall terminate in case of a violation of these contractual stipula tions The registered user shall be obligated to destroy the program and all copies at the termination of the contract WIKA Operati
14. to save them now by choosing Save or Save as in the menu File 5 3 5 Stop Recording If a recording is stopped data are preserved which have been received until that moment WIKA Operating Instructions model CPT2500 10 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 5 3 6 Comment As soon as the data have been read you may enter your com lol x ments here If data are saved as a file the comment will also CPA 2500 48000005 be saved in the same file automatically Instument Data Comment Extras i ere comment template Furthermore there is the possibility to load recurrent comments C Dokumente und Einstellungen ve ea in form of a template Y load automatically load template To do so enter a suitable text file only txt format via button IV overwrite existing comment change Via button load template the text will be loaded Test customer manually to the window If load automatically is activated the previously selected text file is loaded automatically whenever data is read out The comment can be edited afterwards as usual When load automatically activated overwrite existing com ment is selectable This function overwrites the existing com ment when a new record is started example text 5 3 7 Extras This register permits adjustment options for the recording WIES With unit pressure unit of the transducer can be set If necessary Offset and S
15. 25 Tel 64 9 8479020 Fax 64 9 8465964 E Mail info wika co nz www wika co nz 31 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA Global Europe Austria WIKA Messger tevertrieb Ursula Wiegand GmbH amp Co KG 1230 Vienna Tel 43 1 86916 31 Fax 43 1 86916 34 E Mail info wika at www wika at Benelux WIKA Benelux 6101 WX Echt Tel 31 475 535 500 Fax 31 475 535 446 E Mail info wika nl www wika nl Bulgaria WIKA Bulgaria EOOD Bul Al Stamboliiski 205 1309 Sofia Tel 359 2 82138 10 Fax 359 2 82138 13 E Mail t antonov wika bg Croatia WIKA Croatia d o o Hrastovicka 19 10250 Zagreb Lucko Tel 385 16531034 Fax 385 16531357 E Mail info wika hr www wika hr Finland WIKA Finland Oy 00210 Helsinki Tel 358 9 682 49 20 Fax 358 9 682 49 270 E Mail info wika fi www wika fi France WIKA Instruments s a r l 95610 Eragny sur Oise Tel 33 1 343084 84 Fax 33 1 343084 94 E Mail info wika fr www wika fr Italy WIKA Italia Srl amp C Sas 20020 Arese Milano Tel 39 02 9386 11 Fax 39 02 9386 174 E Mail info wika it www wika it Poland WIKA Polska S A 87 800 Wloclawek Tel 48 542 3011 00 Fax 48 542 3011 01 E Mail info wikapolska pl www wikapolska pl Romania WIKA Instruments Romania S R L Bucuresti Sector 5 Calea Rahovei Nr 266 268 Corp 61 Etaj 1 78202 Bucharest Tel
16. 40 21 4048327 Fax 40 21 4563137 E Mail m anghel wika ro Russia ZAO WIKA MERA 127015 Moscow Tel 7 495 648 01 80 Fax 7 495 648 01 81 E Mail info wika ru www wika ru Serbia WIKA Merna Tehnika d o o Sime Solaje 15 11060 Belgrade Tel 381 11 2763722 Fax 381 11 753674 E Mail info wika co yu www wika co yu Spain Instrumentos WIKA S A C Josep Carner 11 17 08205 Sabadell Barcelona Tel 34 933 938630 Fax 34 933 938666 E Mail info wika es www wika es Switzerland Manometer AG 6285 Hitzkirch Tel 41 41 91972 72 Fax 41 41 91972 73 E Mail info manometer ch www manometer ch Turkey WIKA Instruments Istanbul Basinc ve Sicaklik Olcme Cihazlari Ith Ihr ve Tic Ltd Sti Bayraktar Bulvari No 21 34775 Yukari Dudullu Istanbul Tel 90 216 41590 66 Fax 90 216 41590 97 E Mail info wika com tr www wika com tr Ukraine WIKA Pribor GmbH 83016 Donetsk Tel 38 062 34534 16 Fax 38 062 34534 17 E Mail info wika ua www wika ua United Kingdom WIKA Instruments Ltd Merstham Redhill RH13LG Tel 44 1737 644 008 Fax 44 1737 644 403 E Mail info wika co uk www wika co uk w Kall WIKA Alexander Wiegand SE amp Co KG Alexander Wiegand Stra e 30 63911 Klingenberg e Germany Tel 49 9372 1 32 0 Fax 49 9372 1 32 406 E Mail info wika de www wika de WIKA Betriebsanleitung Druckmessumformer 32
17. 9 Data RECODO BE 8 5 31 Connecting et Ae E et 8 332 SSENSOEDAESCHEEN Ee 9 5 3 93 OLA RECON CIO een ee ee RER 9 5 3 4 Displaying the Measurements nenn nenn nenn nenn nenn nenn nenn nennnnnnnenn nenn nenn nenn nenn nennen 10 5 35 S oB FRE COL GING BEE 10 93 06 BEE 11 537 ETAS ee ee E E EE 11 54 File OPS FANON esate cans seetecnaes EES 11 So Ging DAN E 12 5 6 E EIERE elen EE 12 5 65 AGING RR ENEE 13 E EE ee ae BEE 13 5603 Z00mM TUNGO WEE 13 5 6 4 Copying Data to Glipboard EE 13 6 SPECIFICATION Men an ee 14 7 DISPOSAL Late ien Lei LE 15 WIKA Operating Instructions model CPT2500 2 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 1 General The CPA2500 adaptor makes it possible to connect a pressure sensor model CPT2500 directly to the USB port of a personal computer The associated Software USBsoft2500 allows to conduct the moni toring settings and to display the measuring data automatically in the adjusted cycle time This mode is especially adapted for the analysis of pressure curves and the survey of pressure peaks with pre trigger 1 1 Software Operation This operating manual postulates basic knowledge of how to handle a personal computer with the op erating system Windows If this is not existent it is recommended to make oneself familiar with the main features of Windows before installing this software operating manuals specialised literature introductory courses etc 1 2 Software Li
18. COM Port des Adapters ndern Rufen Sie bei angestecktem Adapter unter Start Einstellungen Systemsteuerung System Hard ware den Ger temanager auf und ffnen Sie dort den Unterpunkt Anschl sse COM und LPT Hier steht bei erfolgreicher Installation der Eintrag CP210X USB to UART Bridge Controller COM x wobei das x nach dem COM f r den derzeit verwendeten COM Port steht z B COM 4 WIKA Betriebsanleitung Druckmessumformer 20 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft ffnen Sie durch Doppelklick die Eigenschaften f r diesen Anschluss wechseln Sie zu Anschlusseigen schaften und w hlen dort den Punkt Erweitert Hier kann nun beim Punkt COM Anschlussnummer der gew nschte COM Port eingestellt werden Sollte dieser Port bereits einem anderen auch derzeit nicht angeschlossenen Ger t zugeordnet sein erscheint eine Fehlermeldung Das Setzen von zwei Ger ten auf denselben COM Port ist prinzipiell m g lich Sie m ssen nur gew hrleisten dass nicht beide Ger te gleichzeitig angeschlossen sind da es an sonsten zu einem Konflikt kommt 4 3 Wird ein lterer bereits im System vorhandener Treiber automatisch aktualisiert Nein leider nicht Wird bei der Installation des Ger tes erkannt dass sich bereits ein f r aus der Sicht des Betriebssystems passender Treiber befindet so wird automatisch dieser Treiber verwendet Sollten Sie also Probleme bei der Verwendung d
19. Instruction manual Bedienungsanleitung Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft GB Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft D E USBsoft 2500 Datei USB Messadapter Diagramm Konfiguration Fenster Infg oa S ell ei A Ze er CPA 2500 48000005 Gerat Daten Kommentar Extras l MA ole aaa SEEN ee a Diagramm 1 Datensatze 67 von 20 04 2007 12 27 19 bis 20 04 2007 12 27 26 1 Druck rel 28 tel mbar 1 20 04 2007 12 27 19 000 2 20 04 2007 12 27 13 100 Li 3 20 04 2007 12 27 19 200 4 20 04 2007 12 27 19 300 5 20 04 2007 12 27 19 400 GI 20 04 2007 12 27 19 500 7 20 04 2007 12 27 19 600 8 20 04 2007 12 27 19 700 9 20 04 2007 12 27 19 800 i 10 20 04 2007 12 27 19 900 l x far 12 27 23 12 27 24 20 04 2007 CPA 2500 48000005 1 Druck 51 20 04 2007 12 27 24 000 d imbar CPA 2500 48000005 1 Druck rel mbar V2 2 07 2011 WIKA Alexander Wiegand SE amp Co KG Alexander Wiegand StraBe 30 63911 Klingenberg Germany Phone 49 9372 132 9986 Fax 49 9372 132 8767 E Mail testequip wika de WI KA www wika de Be Part of your business Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft Index I GENERAL orrera ne es ene ea eens 3 Halk OOM Abe Del AO are cette ee oe eee et eae a a
20. Systemvoraussetzungen IBM kompatibler PC Pentium Mind 20 MB freier Festplattenspeicher CD ROM Laufwerk Mind 256 MB Arbeitsspeicher Windows 2000 XP Vista Windows 7 Maus Einen freien USB Port WIKA Betriebsanleitung Druckmessumformer 18 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 2 Allgemeine Betriebshinweise 2 1 Betriebsmodus Mit Hilfe der zugeh rigen Software USBsoft2500 wird der Messumformer konfiguriert und die Messwer te aufgezeichnet Einstellbare Parameter sind hierbei unter anderem Zykluszeit 1 ms 10 sec programmierbar in ms Schritten Messwerte Zykluszeit lt 5 ms es kann der aufzuzeichnende Wert Messwert min Peak max Peak gew hlt werden Zykluszeit gt 5 ms es wird immer ein vollstandiger Datensatz aufgezeichnet der die folgenden Messwerte enthalt aktueller Druck zum Zeitpunkt der Daten bertragung Minimaldruck min Peak im Zeitraum der letzten Zykluszeit Maximaldruck max Peak im Zeitraum der letzten Zykluszeit Mittelwert des Druckes ber den Zeitraum der letzten Zykluszeit Triggerbedingungen 5 f r Aufzeichnungsstart 6 f r Aufzeichnungsstopp Pre Trigger 50 Datens tze bei Zykluszeit gt 5 ms bzw 200 Messwerte Zykluszeit lt 5 ms Die Messung wird mittels einer Triggerbedingung gestartet und das Ger t gibt dann automatisch ohne weitere Aufforderung in der eingestellten Zykluszeit die Messwerte aus bis die Stopp Bedingung
21. USB Adapler verbinden eet 23 9 3 2 EISE EIERE 23 999 WAUIZEICAMUNG STAM CM EE 23 534 ag E EE 25 5 3 5 Aufzeichnung stoppen 25 5 3 6 Kommentar hinzuf gen Textvorlagen embunden nenne nennen 25 Gr EE 25 54 EE 26 54A Dateien EX DO MUCKOM EE 26 5 4 2 Daten in die Zwischenablage kopieren nenn enenn nenne nenn nenn nenne nennen 26 55 Baten e te WEE 26 5 6 lee 27 5 6 1 Datenbeschriftungen bm zutugen nenn nnnnnnnn nenn nenn nenn nenn nenn nenn nenn nenn nennen 27 562 IMESSTEIHEH NINZUIUGEN seen 27 5 6 3 Zoomen Vergr ern eines DBldausschnttes 000 nno nen nnn nennen 28 5 6 4 Diagramme in die Zwischenablage kopieren cccceecceecceeeceeeceeeceeeceeceeeceeceeeseeeceeesees 28 Sa Neie lte e TC DATEN WEE 29 7 ENTSORGUNGSHINWEISE re ee egee 30 WIKA Betriebsanleitung Druckmessumformer 16 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 1 Allgemein Der USB Adapter CPA2500 erm glicht die direkte Anbindung eines Druckmessumformers Typ CPT2500 an die USB Schnittstelle eines PCs Mit Hilfe der zugeh rigen Bedien und Auslesesoftware USBsoft2500 k nnen die Einstellungen f r das Aufzeichnen von Messwerten des Druckmessumformers CPT2500 vorgenommen werden Weiterhin k nnen die aufgezeichneten Messwerte graphisch dargestellt und analysiert werden 1 1 Bedienung der Software Diese Bedienungsanleitung setzt Grundkenntnisse in der Bedienung eines PCs unter dem Betriebssys tem Windows voraus Sollte
22. ailable quod vide chapter 6 4 Frequently asked questions FAQ 4 1 How to check whether the adapter has been installed correctly and via which COM port can approach the installed adapter Start the Device Manager Win XP click start settings control panel performance and maintenance system hardware and open the submenu Ports COM amp LPT If the installation was successful there will be the entry CP210X USB to UART Bridge Controller COM x in which the x after the Com indicates the available COM port i e COM 4 Note The adapter will not be shown in the device manager if it is not connected to the PC lf the entry is occupied by an exclamation mark or the entry is not there then the driver has not been installed correctly 4 2 How to change the COM port of the adapter Make sure that the adapter is connected start the Device Manager Win XP click start settings con trol panel performance and maintenance system hardware and open the submenu Ports COM amp LPT If the installation was successful there will be the entry CP210X USB to UART Bridge Controller COM x in which the x after the Com indicates the available COM port i e COM 4 Open the features of this connection by a double click go to Port Settings and then click there the button Advanced There you can choose the preferred COM Port at the point COM Port Number If this port is already
23. alaysia WIKA Instrumentation M Sdn Bhd 47100 Puchong Selangor Tel 60 3 80 63 10 80 Fax 60 380 63 10 70 E Mail info wika com my www wika com my Singapore WIKA Instrumentation Pte Ltd 569625 Singapore Tel 65 68 44 55 06 Fax 65 68 44 55 07 E Mail info wika com sg www wika com sg Taiwan WIKA Instrumentation Taiwan Ltd Pinjen Taoyuan Tel 886 3 420 6052 Fax 886 3 490 0080 E Mail info wika com tw www wika com tw WIKA Betriebsanleitung Druckmessumformer Africa Middle East Egypt WIKA Near East Ltd El Serag City Towers Tower 2 Office 67 Nasr City Cairo Tel 20 2 22733140 Fax 20 2 22703815 E Mail wika repcairo wika de www wika com eg Namibia WIKA Instruments Namibia Pty Ltd P O Box 31263 Pionierspark Windhoek Tel 26 4 6123 8811 Fax 26 4 6123 3403 E Mail info wika com na www wika com na South Africa WIKA Instruments Pty Ltd Gardenview Johannesburg 2047 Tel 27 11 62100 00 Fax 27 11 62100 59 E Mail sales wika co za www wika co za United Arab Emirates WIKA Middle East FZE Jebel Ali Dubai Tel 971 4 8839 090 Fax 971 4 8839 198 E Mail wikame emirates net ae Australia Australia WIKA Australia Pty Ltd Rydalmere NSW 2116 Tel 61 2 88455222 Fax 61 2 96844767 E Mail sales wika com au www wika com au New Zealand WIKA Instruments Limited Unit 7 49 Sainsbury Road St Lukes Auckland 10
24. asse B und St rfestigkeit Gewerbebereich Labor Servicebereiche oder Werkst tten CE Konformit t CPA2500 EMV Richtlinie 2004 108 EG EN 61326 Emission Gruppe 1 Klasse B und St rfestigkeit beherrschte elektromagnetische Umgebung Dieses Ger t ist f r den Betrieb in beherrschter elektromagnetischer Umgebung entwickelt worden wie z B La bor oder Pr fbereiche Sendefunkger te oder Mobilfunktelefone d rfen nicht in unmittelbarer N he des Ger ts benutzt werden 7 Entsorgungshinweise Das Ger t darf nicht ber die Restm lltonne entsorgt werden Soll das Ger t entsorgt werden senden Sie dieses direkt an uns ausreichend frankiert Wir entsorgen das Ger t sachgerecht und umweltschonend WIKA Betriebsanleitung Druckmessumformer 30 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA Global North America Canada WIKA Instruments Ltd Head Office Edmonton Alberta T6N 1C8 Tel 1 780 46370 35 Fax 1 780 46200 17 E Mail info wika ca www wika ca Mexico Instrumentos WIKA Mexico S A de C V 01210 Mexico D F Tel 52 55 55466329 E Mail ventas wika com www wika com mx USA WIKA Instrument Corporation Lawrenceville GA 30043 Tel 1 770 5138200 Fax 1 770 3385118 E Mail info wika com www wika com WIKA Instrument Corporation Houston Facility 950 Hall Court Deer Park TX 77536 Tel 1 713 475 0022 Fax 1 713 475 0011 E mail info wikahouston com www w
25. cale can be corrected The low pass filter provides the possibility for suppressing pressure me a peaks Offset a mba Scale 0 000 Lowpass filter value Io 0 00 10 00 5 4 File Operation For viewing or analysing saved data can be reloaded by performing the following steps Select File open and open the corresponding file Export Files The data files can be saved as ASCII text file to view them for example in word processing or in a spread sheet program Select the required data window and choose file export at the menu Pay attention particularly at spread sheets to make right settings in the following export files pop up win dow WIKA Operating Instructions model CPT2500 11 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 5 5 Print Data The respectively selected window data or diagram can be printed via Printer DEKLI150201 DEKLNP3019 d File Print Precondition is that a printer has been installed to your Page margins Print Options Data File Pri d Printdat i A4 Gite GR File nn nn m m z A fist 21 09 2003 15 44 34 o change printer parameters Or to S mmm Ia last 21 09 2009 15 44 36 choose another printer Sch mm JW path All Data Under Pictures additionally header et 5 m or footer pictures can be integrated to fight fE mm Caen Zeie ann GEIS dam the printouts e portrai Je Dokumente und Ei j I landscape The pictures or othe
26. cense Agreement The subject matter of the contract is the programs operating instructions and miscellaneous appertain ing material recorded on CD ROM As a registered user you shall be permitted e to use the copy of the program contained on a single computer e to produce a backup copy The copyright note of WIKA shall have to be attached to this backup copy As a registered user you shall be not permitted e to hand over to a third party or to make accessible to a third party the program without prior written approval of WIKA e to install the program in any form on a multi user system e to copy in whole or in part with the exception of the backup copy to modify to translate to back develop to decompile to disassemble or to decode the program as well as to set up derived vari ants from the program By purchasing the program you shall only obtain ownership in the CD ROMs on which the program is recorded The ownership in the rights of the program proper shall not be obtained All rights to publica tion duplication processing and exploitation of the program shall remain with WIKA WIKA guarantees that the CD ROM on which the program was recorded is free from defects in material under normal operating conditions If the data carriers have a defect the said can be returned to WIKA within a period of thirty days after the date of first purchase The CD ROMs will be replaced immediate ly free of charge WIKA guarantees that the
27. d zusammen mit der Nullpunktkorrektur s o vor allem zum Abgleich von Sen sorabweichungen verwendet Die Eingabe erfolgt in der Konfigurationssoftware Die Scale Information wird im Sensor gespeichert kann also fur jeden Sensor getrennt durchgefuhrt werden WIKA Betriebsanleitung Druckmessumformer 19 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 2 5 Druckanschluss an die Drucksensoren Der Messadapter ist so konzipiert dass alle Druckmessumformer vom Typ CP T2500 ohne Neuabgleich angesteckt werden k nnen Somit stehen Ihnen eine Vielzahl austauschbarer Sensoren mit Messberei chen von 1 O bar bis 0 1000 0 bar sowie von 0 0 25 bar absolut bis O 25 bar absolut zur Aus wahl F r berdruck bzw Absolutdruckmessungen Sensor in Gewinde G1 2 einschrauben oder Kunststoff schlauch ber passenden Adapter an Drucksensor anstecken 2 6 Hinweis zum Kalibrierservice Werkskalibrierschein DKD Schein amtliche Bescheinigungen Soll das Messger t einen Kalibrierschein erhalten ist dieses mit dem zugeh rigen F hler zum Hersteller einzuschicken Nur der Hersteller kann die Einstellungen berpr fen und wenn notwendig korrigieren 3 Treiber Installation 3 1 Windows 2000 Windows XP und Windows Vista bzw Windows 7 F r die Installation der Ger tetreiber ist ein Benutzerkonto mit Administrator Rechten erforder lich Sollten Sie diese Rechte nicht besitzen so melden Sie sich mit einem entspr
28. echenden Kon to an oder fragen Sie Ihren Systemadministrator Legen Sie den Datentr ger mit dem Treiber in Ihr Laufwerk ein Starten Sie nun entsprechend Ihres Betriebssystems den Installer f r den Treiber vom Datentr ger CP210XVCPinstaller exe Folgen Sie nun den Anweisungen des Installationsprogrammes Stecken Sie den CPA2500 an den USB Anschluss Ihres PCs an Der CPA2500 wird nun automatisch mit dem aktuellen Treiber installiert Der CPA2500 ist nun auf Ihrem System installiert und steht damit allen Benutzern zur Verf gung F r die Verwendung mit der Software USBsoft2500 steht Ihnen nun ein weiterer COM Port zur Verf gung siehe auch Kapitel 4 4 H ufig gestellte Fragen FAQ 4 1 Wie kann ich berpr fen ob der Adapter korrekt installiert wurde und unter wel chem COM Port kann ich den neu installierten Adapter nun ansprechen Rufen Sie unter Start Einstellungen Systemsteuerung System Hardware den Ger temanager auf und ffnen Sie dort den Unterpunkt Anschl sse COM und LPT Hier steht bei erfolgreicher Installation der Eintrag CP210X USB to UART Bridge Controller COM x wobei das x nach dem COM f r den nun verf gbaren COM Port steht z B COM 4 Hinweis Damit der Adapter im Ger temanager angezeigt wird muss er am PC angesteckt sein Sollte der Eintrag mit einem Ausrufezeichen versehen sein oder nicht enthalten sein so wurde der Treiber nicht korrekt installiert 4 2 Wie kann ich den
29. ee Reece ee a eae 3 1 2 Software License AGES MEN E 3 E DEN EE e EE 4 14 eege 4 2 GENERAL HANDLING INSTRUCTIONS 2224222202220202000000n00nnn00nnnnunnnnunnnnnunnnnunnnnnnnnnnunnnnnnnnnnunnnn 5 Zak OBErallon Mod nun 5 22 TOCONMECL Change sensor riesen Helene 5 2 3 Zero correction of the pressure sensor OFF 5 2 4 Slope correction of the pressure sensor GCGAU nenn anne nenne nenn nnnne nenne nenn nam nnnenn 5 2 5 Pressure CONNECTION to the pressure sensor anne anne anne nen nnnn nen anne nenne 5 26 POVICC TON elle ele LE e 6 3 REINERS HN HIEN 6 3 1 Windows 2000 Windows XP Windows Vista and Wmdowe 6 A FREQUENTLY ASKED QUESTIONS FAQ ann 6 4 1 How to check whether the adapter has been installed correctly and via which COM port can approach the installed adapter cccccceeccceecceeeeceeeceececeueeceuecsucecueeeueessueesseeesueessueeseeessaseseeees 6 4 2 Howto change the COM port of the adapter cccccecccceecceseeeeceeeeseeeeeseeeeseeeeeseeeeseeeessaeeesees 6 4 3 Is there an automatic update function that updates the installed driver to the latest version 6 4 4 How to find out the used version of the driver u222022s0sssusnnnnnnnnnnnnnnnnnnnnnnnnnnn nenn san nnennnenen 7 4 5 How to update a driver of an older version or how to uninstall the drver 7 5 OPERATING SOFTWARE USBSOP T2500 uns EEN 7 a We e a AO 7 52 EE 8 T A ME Re 8 52 2 TOODA epp E E E E A E E ERE EpC 8 5
30. en gew nschten Datenbereich mit der Maus markieren Alle Daten mar kieren oberstes linkes Feld der Tabelle anklicken und Tastenkombination Strg C dr cken gt Die Tabellendaten werden in die Zwischenablage kopiert 5 5 Daten drucken Das jeweils ausgew hlte Fenster Drucken CA 200 Daten oder Diagramm kann mit Datei Drucken ausgedruckt Drucker ADEKLIVSOZ01 DEKLIP3019 werden Voraussetzung ist dass ein Drucker an ihrem Computer a Druckoptionen Daten peewee 7 Druckdatum von 21 03 2003 bus Formulargestaltung en Unter zus Bilder kann eine Kopf Info bis 21 09 2003 11 1702 und Fu zeile eingebunden wer G Piad WEEN den Dazu mussen die Bilder Tex 15 le Logos oder eren Le Emm ines an Bide liegen Bildgr e muss vorher Hochformat E Standard G Oue E angepasst werden Der Ausdruck Querformat 7 Fu zeilen Bil ndern kann so in ein individuelles For mular verwandelt werden Abbrechen Ok WIKA Betriebsanleitung Druckmessumformer 26 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 5 6 Messwertdiagramme Die geladenen Daten der Messwertfenster k nnen auch in Diagrammen dargestellt werden Wahlen Sie hierzu neues Diagramm erstellen im Men Diagramm Sie erhalten dann die Auswahl der m glichen Kurven W hlen sie die gew nschten Kurven aus und best tigen Sie mit OR Das Diagramm wird ge ffnet Einschr nkung max 2 verschiedene Einheiten
31. er ndert werden Im Register Kommentar k nnen Sie beliebige Texte eingeben Wollen Sie die Daten zu einem sp teren Zeitpunkt noch einmal betrachten dann speichern Sie jetzt indem Sie Speichern oder Speichern unter im Men Datei ausw hlen 5 3 5 Aufzeichnung stoppen Wird eine Aufzeichnung gestoppt bleiben die bis dahin gespeicherten Daten erhalten 5 3 6 Kommentar hinzuf gen Textvorlagen einbinden Sobald Daten vorhanden sind k nnen im Re gister Kommentar beliebige Texte eingegeben CPA 2500 48000005 werden Dieser Kommentar wird ausgedruckt und auch mit abgespeichert Es gibt auch die mrene M glichkeit Vorlagen f r immer wieder kehren Se es SE de Texte zu laden Dazu Uber ndern die 7 vorhandenen Kommentar berschreiben selbsterstellte Vorlage nur Text Dateien zul s sig ausw hlen ber die Taste Vorlage la ae den wird der Text manuell in das Fenster gela Max Muster den Ist automatisch laden aktiviert wird der zuvor ausgew hlte Kommentar automatisch geladen Der Kommentar Text kann jetzt auch noch an gepasst ge ndert oder erg nzt werden Wenn automatisch laden aktiviert ist kann zus tzlich noch die Funktion vorhandenen Kommentar berschreiben ausgew hlt werden Dadurch wird ein bereits vorhandener Kommentar mit dem neuen berschrieben wenn eine neue Aufzeichnung gestar tet wird SES CPA 2500 48000005 vi Druckpriuftung Unterschrift 5
32. erf llt ist 2 2 Sensoren anstecken wechseln In Verbindung mit dem USB Adapter CPA2500 d rfen nur Druckmessumformer vom Typ CPT2500 verwendet werden Mit anderen Sensoren kann es zur Zerst rung des Adapters und des Sensors kommen Zum Sensorwechsel ist der Adapter abzustecken Sensoren vor dem Aktiveren des Adapters anstecken sonst wird er vom Adapter evil nicht richtig erkannt Beim Anstecken kann es vorkommen dass der Stecker nicht richtig in die Buchse einrastet In diesem Fall den Stecker beim Anstecken nicht an der Steckerh lse sondern am Knickschutz halten Stecker nicht verkantet anstecken Bei richtig angesetztem Stecker kann dieser ohne gr eren Kraftaufwand einge steckt werden Beim Abstecken der Sensoren nicht am Kabel ziehen sondern nur an der Steckerh lse 2 3 Nullpunktkorrektur des Drucksensor OFFS F r die Messung kann eine Nullpunktverschiebung vorgenommen werden angezeigter Wert gemessener Wert Offset Die Nullpunktkorrektur wird zusammen mit der Steigungskorrektur s u vor allem zum Abgleich von Sen sorabweichungen verwendet Die Eingabe erfolgt in der Konfigurationssoftware Die Offset Information wird im Sensor gespeichert kann also fur jeden Sensor getrennt durchgefuhrt werden 2 4 Steigungskorrektur des Drucksensor SCAL Die Steigung der Messung kann mit diesem Faktor beeinflusst werden Faktor ist in angezeigter Wert gemessener Wert 1 Scale 100 Die Steigungskorrektur wir
33. es Adapters haben so stellen Sie bitte zuerst sicher dass auch der aktuelle Treiber f r den Adapter verwendet wird und installieren Sie ggf den aktuellen Treiber manuell siehe 4 5 4 4 Wie kann ich die verwendete Treiberversion feststellen F r die Verwendung des Adapters sind 2 installierte Ger tetreiber erforderlich Zum einen das USB Composite Device f r das USB Ger t an sich und der USB to UART Bridge Controller f r die Bereit stellung des COM Ports Rufen Sie bei angestecktem Adapter unter Start Einstellungen Systemsteuerung System Hard ware den Ger temanager auf F r den USB Ger tetreiber ffnen Sie im Ger temanager den Unterpunkt USB Controller und anschlie Bend durch Doppelklick die Eigenschaften f r den Anschluss CP210X USB Composite Device und wechseln Sie zu Treiber F r den COM Treiber ffnen Sie im Ger temanager den Unter Allgemein Anschlusseinstellungen Treiber punkt Anschl sse COM und LPT und anschlie end durch Dop pelklick die Eigenschaften fur den Anschluss CP210X USB to UART Bridge Controller COM x und wechseln Sie zu Treiber EE EE CP210 USE to USAT Bridge Controller IL OMAI Treiberdatum 16 12 2004 Hier k nnen Sie bei dem Punkt Treiberversion jeweils den aktuell SE verwendeten Treiber ermitteln Digitale Signatur Nicht digital signiert 4 5 Wie kann ich eine ltere Treiberversion aktualisieren bzw deinstallieren
34. esspunkte mit einem Kommentar zu versehen w hlen Sie den Men punkt Diagramm Datenbeschriftung hinzuf gen oder das entspr Symbol Wenn Sie die Maus ber das Diagramm be wegen erscheint als Mauszeiger das Symbol Ein Mausklick an die gew nschte Stelle platziert einen einzeiligen Text der frei gew hlt werden kann 5 6 2 Messreihen hinzuf gen Um in einem Diagramm weitere Messreihen darzustellen w hlen Sie den Men punkt Diagramm Messreihe hinzuf gen oder das entsprechende Symbol des Diagrammfensters an Es erscheint wieder die Auswahl der Datenquellen und Sie k nnen weitere Messreihen ausw hlen WIKA Betriebsanleitung Druckmessumformer 27 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 5 6 3 Zoomen Vergr ern eines Bildausschnittes Falls 2 Einheiten dargestellt sind Mit den Symbolen B und amp die gew nschte Y Achse ausw hlen Die Maus an den Anfang des gew nschten Bereichs f hren linke Maustaste gedr ckt halten Maus bis an das Ende des gew nschten Bereiches bewegen Maustaste loslassen der Ausschnitt wird vergr Bert gezoomt Mit Diagramm Zoom zur ck wird der vorher betrachtete Bildausschnitt wieder hergestellt Mit Diagramm Zoom alles wird das gesamte Diagramm wiederhergestellt Der vergr erte Ausschnitt kann mit den Bildlaufleisten nach links rechts oben und unten bewegt werden Sollen genaue Bildausschnitte dargestellt werden empfiehlt sich die Funkti
35. face of a personal computer With this dedicated software it is possible to start stop read in and display recordings For visualisation and for a better overview the recorded data can be shown in diagrams 5 1 Software Installation Start Windows Insert CD ROM in CD ROM drive Select Execute in Menu Start Enter D setup D stands for the letter of your CD ROM drive press the return key In case your CD ROM drive is not D please use the corresponding letter Follow the instructions given by the installation program e Anew program group with the following program icon will be created The software will be started by double clicking on this symbol WIKA Operating Instructions model CPT2500 7 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft e Start program choose the language you desire and the interface to which you have connected your interface adapter 5 2 Screen Elements 5 2 1 Menu bar You can easily have access to all software functions by using the menu bar The content of the menu bar depends on the program status File USB measuring adapter Diagram Configuration Window About 5 2 2 Toolbar To ensure comfortable software operation the most important software functions have been put togeth er at the Toolbar Moving the mouse pointer over a symbol shows a short description of the function The content of the toolbar depends on the program status co Ge S amp gt m oi Zil
36. ferenzbedingungen Zul ssige m Messstofftemperatur u 25 100 m Umgebungstemperatur C 20 80 m Lagertemperatur C 40 80 Kompensierter Temperaturbereich C Han CH Temperaturkoeffizienten m Mittlerer TK Nullpunkt I K 0 2 10 lt 0 4 f r Messbereiche lt 250 mbar m Mittlerer TK Messspanne K 0 2 10 Kalibrierung Werkskalibrierschein optional DKD Kalibrierschein Gewicht g ca 220 Spezifische Angaben USB Adapter Typ CPA2500 Druckeinheiten mbar bar kPa MPa mmHg psi mMH O umschaltbar je nach verwendetem Sensor Aufzeichnungsoptionen wahlbare Start Stop Bedingungen Pretrigger Stoppverzogerung Max Bereich 19999 bis 19999 Digit Messunsicherheit FS 0 2 bei Nenntemperatur von 25 C Messzyklus 1 ms bis 10s Messrate 1 000 Messungen sec PC Anschluss Standard USB Stecker Typ A Messumformer Rundsteckverbinder 7 polig M16 x 0 75 Hilfsenergie Versorgung Uber die USB Schnittstelle Arbeitsbedingungen C 25 50 0 95 rel Feuchte nicht betauend Nenntemperatur ge SH Lagertemperatur a 25 70 Abmessungen mm ca 56 x 31 x 24 Kabell nge m ca 1 4 Gewicht g ca 120 WIKA Betriebsanleitung Druckmessumformer 29 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft CE Konformitat CPT2500 Druckgeraterichtlinie 97 23 EG Module A druckhaltendes Ausrustungsteil EMV Richtlinie 2004 108 EG EN 61326 Emission Gruppe 1 Kl
37. fully exchangeable sensors for metering ranges of 1 O bar relative to 0 1000 bar absolute are available For overpressure low pressure or absolute pressure measurements screw the sensor in the threat G1 2 or connect a flexible hose with an appropriate adapter to the pressure sensor WIKA Operating Instructions model CPT2500 5 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 2 6 Advice for calibration service Factory calibration certificate DKD certificate ministerial certifications lf the measuring device shall have a calibration certificate you have to send it inclusive the sensor to the manufacturer Just the manufacturer can check the factory settings and correct them if necessary 3 Driver Installation 3 1 Windows 2000 Windows XP Windows Vista and Windows 7 For installation of the device drivers a user account with an administrator authorisation is re quired If you haven t an appropriate authorisation please consult your system administrator Insert driver disk into the drive of your PC Start the installer CP210XVCPinstaller exe from drive Follow the instructions of the install wizard Plug in the USB plug connector of the CPA2500 into the USB connection of your PC Now the CPA2500 will be installed automatically with the actual driver Now the CPA2500 is installed on your system and available for all users For application with our software a new additional COM Port is av
38. gen f r die Messwertaufzeichnung Zykluszeit Hier bestimmen Sie in welchen Intervallen Messwerte aufgenommen werden sollen Hinzu kommt dass Sie w hlen k nnen welcher Wert ausgegeben wird Zur Auswahl stehen der aktuelle Messwert der Messwert Min Max Wert Dabei ist zu beachten bei einer Zykluszeit von gt 5 ms werden automatisch alle Messkan le ausge w hlt Eine direkte Auswahl ist in diesem Fall nicht mehr m glich Start Unter den verschiedenen Startbedingungen ist die gew nschte Bedingung auszuw hlen Bei der Einstellung sofort beginnt die Messwertaufnahme direkt nach dem Starten Bei den anderen Bedingungen sind entsprechend ein oder mehrere Schwellwerte einzugeben werden diese unter oder berschritten ist die Bedingung je nach gew hltem Fall erf llt oder nicht Die Eingabe der Schwellwerte erfolgt in der Maske auf der rechten Seite Sie k nnen auch w hlen welches Startsignal zum Messungsstart f hren soll Dies ist allerdings nur m glich wenn die Zykluszeit gt 5 ms betr gt Diese Eingabe k nnen Sie auf der linken Seite unter Startsignal vornehmen Der PreTrigger erm glicht es Ihnen Werte vor der eigentlichen Messwertaufnahme zu erfassen Nach erfolgreicher Messung werden diese zus tzlichen Messwerte in dem Register Daten mit angezeigt Bei einer Zykluszeit von lt 5 ms werden 200 Einzelmesswerte erfasst Bei einer Zykluszeit von gt 5 ms werden 50 Datens tze bestehend aus je
39. ika com Mensor Corporation 201 Barnes Drive San Marcos TX 78666 Tel 1 512 3964200 15 Fax 1 512 3961820 E Mail sales mensor com www mensor com South America Argentina WIKA Argentina S A Buenos Aires Tel 54 11 47301800 Fax 54 11 47610050 E Mail info wika com ar www wika com ar Brazil WIKA do Brasil Ind e Com Ltda CEP 18560 000 Iper SP Tel 55 15 34599700 Fax 55 15 32661650 E Mail marketing wika com br www wika com br Chile WIKA Chile S PA Av Coronel Pereira 101 Oficina 101 Las Condes Santiago de Chile Tel 56 9 66084258 Fax 56 2 3346219 E Mail info wika cl www wika cl Asia China WIKA Shanghai Office A2615 NO 100 Zuyi Road Changning District 200051 Shanghai Tel 86 21 538525 72 Fax 86 21 538525 75 E Mail info wika com cn www wika com cn India WIKA Instruments India Pvt Ltd Village Kesnand Wagholi Pune 412 207 Tel 91 20 66293 200 Fax 91 20 66293 325 E Mail sales wika co in www wika co in Japan WIKA Japan K K Tokyo 105 0023 Tel 81 3 543966 73 Fax 81 3 543966 74 E Mail info wika co jp Kazakhstan WIKA Kazakhstan LLP 169 Rayimbek avenue 050050 Almaty Kazakhstan Tel 7 32 72330848 Fax 7 32 72789905 E Mail info wika kz www wika kz Korea WIKA Korea Ltd 569 21 Gasan dong Seoul 153 771 Korea Tel 82 2 869 05 05 Fax 82 2 869 05 25 E Mail info wika co kr www wika co kr M
40. messumformer CPT2500 mit USB Adapter CPA2500 und USBsoft WIKA macht darauf aufmerksam dass der Lizenznehmer fur alle Schaden aufgrund von Urheber rechtsverletzungen haftet die WIKA aus einer Verletzung dieser Vertragsbestimmungen durch den Lizenznehmer entstehen Durch das Offnen der Verpackung erklaren Sie sich mit den Vereinbarungen einverstanden 1 3 Sicherheitshinweise Dieses Ger t ist gem den Sicherheitsbestimmungen f r elektronische Messger te gebaut und gepr ft Die einwandfreie Funktion und Betriebssicherheit des Ger tes kann nur dann gew hrleistet werden wenn bei der Benutzung die allgemein blichen Sicherheitsvorkehrungen sowie die ger tespezifischen Sicherheitshinweise in dieser Bedienungsanleitung beachtet werden 1 Warnung ffnen Sie Anschl sse nur im drucklosen Zustand Warnung Betreiben Sie das Druckmessger t immer innerhalb des berlastgrenzbereichs EMV Hinweis Keine Leitungen anschlie en die l nger als 3 m sind Sicherheits Hinweis Lassen Sie Reparaturen nur vom Hersteller durchf hren Die einwandfreie Funktion und Betriebssicherheit des Ger tes kann nur unter den klimatischen Ver h ltnissen die im Kapitel Technische Daten spezifiziert sind garantiert werden 6 Bei unsachgem er Handhabung des Schnittstellenadapters kann dieser selbst besch digt werden Ebenso ist es m glich dass Ihre angeschlossenen Ger te gesch digt werden In diesem Fall besteht kein Garantieanspruch
41. n diese nicht vorhanden sein ist es empfehlenswert sich vor der Installa tion mit den Grundzugen von Windows vertraut zu machen Handb cher Fachliteratur Einf hrungs Kurse etc 1 2 Softwarelizenzvereinbarung Als Lizenznehmer sind Sie berechtigt die enthaltene Kopie des Programms auf einem oder mehreren Computern zu nutzen sowie eine Sicherungskopie anzufertigen Dabei ist auf der Sicherungskopie der Urheberrecht Vermerk von WIKA anzubringen Als Lizenznehmer ist Ihnen untersagt das Programm ganz oder teilweise abzu ndern zu bersetzen zur ckentwickeln zu dekompilieren zu entassemblieren oder zu decodieren sowie von dem Pro gramm abgeleitete Werke zu erstellen Sie erhalten mit dem Erwerb des Programmes nur das Eigentum an den CD Roms auf denen das Programm aufgezeichnet ist Ein Erwerb an Rechten des Programmes selbst ist damit nicht verbunden Alle Rechte zur Ver ffentlichung Vervielf ltigung Bearbeitung und Verwertung des Programmes ver bleiben bei WIKA WIKA gew hrleistet dass die CDs auf denen das Programm aufgezeichnet ist unter normalen Be triebsbedingungen in Materialausf hrung einwandfrei sind Sollten die Datentr ger einen Fehler auf weisen so k nnen innerhalb einer Frist von 30 Tagen ab Datum des Ersterwerbs die Datentr ger an WIKA eingeschickt werden Die CD Roms werden umgehend kostenlos ersetzt WIKA gew hrleistet dass das Programm im Sinne der Programmbeschreibung grunds tzlich brauch ba
42. ng Instructions model CPT2500 3 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft WIKA wish to point out that the registered user shall be liable for all damage caused by the violation of the copyrights which occur to WIKA from the violation of these contractual stipulations by the registered user 1 3 Safety regulations This device was designed and tested considering the safety regulations for electronic measuring devic es Faultless operation and reliability in operation of the measuring device can only be assured if the General Safety Measures and the devices specific safety regulation mentioned in this operating instruc tion are considered 1 Warning Open pressure connections only after the system is without pressure 2 Warning Please make sure that the pressure sensor is only used within the overpressure safety limit 3 EMC advice Do not connect a cable that exceeds a length of 3 m Safety advice Have repairs performed by the manufacturer only 5 Faultless operation and reliability in operation of the measuring device can only be assured if the device is used within the climatic conditions specified in the chapter Specification 6 By faulty handling of the interface adapter a damage of the device cannot be excluded Likewise a damage of your attached device is possible In such case we cannot assume any warranty The manufacturer will not assume any warranty for damages to other devices resulting by
43. on Diagramm Ein stellungen Damit kann ein gew nschter Ausschnitt per Zahlen und Zeitangabe eingestellt werden 5 6 4 Diagramme in die Zwischenablage kopieren Diagramme k nnen in die Zwischenablage kopiert werden um in anderen Anwendungen wieder einge f gt zu werden Das betreffende Diagramm anklicken Tastenkombination Strg C dr cken gt Das Diagramm wird als Bitmap in die Zwischenablage kopiert WIKA Betriebsanleitung Druckmessumformer 28 Druckmessumformer CPT2500 mit USB Adapter CPA2500 und USBsoft 6 Technische Daten Spezifische Angaben Drucktransmitter Typ CPT2500 Messbereich bar 0 1 0 16 1025 0 4 0 6 1 1 6 2s 6 berlastgrenze bar 1 15 2 2 4 5 10 10 17 35 Berstdruck bar 2 2 2 4 2 4 4 8 6 12 12 20 5 42 Aufl sung mbar 0 1 1 Messbereich bar 10 16 25 40 60 100 160 250 400 600 1000 Uberlastgrenze bar 35 80 50 80 120 200 320 500 800 1200 1500 Berstdruck bar 42 96 250 400 550 800 1000 1200 1700 2400 3000 Auflosung bar 0 01 0 1 Druckart Relativdruck Absolutdruck von 0 25 bis 16 bar abs und Vakuummessbereich auf Anfrage Druckanschluss G 1 2 diverse Anschlussadapter auf Anfrage Werkstoff Messstoffber hrte Teile CrNi Stahl ab 40 bar zus tzlich mit Dichtung NBR m Geh use CrNi Stahl m Interne bertragungsfl ssigkeit synthetisches l nur bei Messbereichen bis 16 bar Stabilit t pro Jahr 0 2 der Spanne bei Re
44. pprox 56 x 31 x 24 Cable length m approx 1 4 Weight g approx 120 WIKA Operating Instructions model CPT2500 14 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft CE conformity CPT2500 Pressure equipment directive 97 23 EC module A pressure accessory EMC directive 2004 108 EC EN 61326 Emission Group 1 Class B and Immunity commercial area i e workshops laboratories or service centres CE conformity CPA2500 EMC directive 2004 108 EC EN 61326 Emission Group 1 Class B and Immunity controlled electromagnetic environment This equipment is designed for operation in a controlled electromagnetic environment e g test or laboratory envi ronments RF transmitters such as mobile telephones may not be used in close proximity 7 Disposal instructions The device must not be disposed in the regular domestic waste send the device directly to us sufficiently stamped if it should be disposed We will dispose the device appropriate and environmentally sound WIKA Operating Instructions model CPT2500 15 Druckmessumformer CPT2500 mit USB Adapter CPA2500 Inhaltsverzeichnis 1 ABLE GEMEIN EE 17 1 1 Bedienung Bee ug EE 17 1 2 SoftwarelizenZvereinbarung ccscecccsececcseesesececcseccceeesecececcuececsecseceeecceeeesceessoeeeesceeesoeeesess 17 153 SICMErNEILSMINW CISE sacaran casi a eine Denen 18 14 SVSICMVOlAUSSEIZUNGEN EE 18 2 ALLGEMEINE BETRIEBSHINWEISE ne 19 2 BEILIEDSMIOAUS EE 19
45. r CPA2500 and USBsoft To start a new recording please select start new recording or click at the corresponding toolbar symbol Now you can choose from an assortment of start and stop conditions and define the output data Choice of the recording mode Output Cycle time here you can decide in which intervals measuring points should be recorded At the same time you can select which value will be displayed measured value min max peak Please note at a cycle time of more or equal than 5ms all measured values will be selected automati cally A direct selection is no longer possible Start You have to select the desired condition under the different possibilities If immediately is se lected the measuring will start directly after starting it At the other conditions you have to define one or more thresholds if these are under or overrun the condition depending on the selected case is fulfilled or not The thresholds entry is carried out in the mask on the right side You even can select which signal shall cause the measuring start But this is only available when the cycle time is higher or equal than Sms You can make this entry on the left side under Start Signal The preTrigger makes it possible for you to detect values before the normal values measured after the start condition After the completion measurement the additional measured values will be shown in the register Data too At a cycle time of less
46. r abs and vacuum on request Pressure connection Di others by adapters on request Material m Wetted parts stainless steel from 40 bar additionally with sealing gasket NBR m Housing stainless steel Internal transmission fluid synthetic oil only pressure ranges up to 16 bar One year stability 0 2 of span at reference conditions Permissible m Medium temperature C 25 100 m Ambient temperature C 20 80 m Storage temperature C 40 80 Compensated range C 0 70 Temperature coefficients m Mean tc of Zero signal IK 0 2 10 lt 0 4 for pressure ranges lt 250 mbar Mean tc of span K 0 2 10 Calibration 3 1 calibration certificate per DIN EN 10 204 option DKD calibration certificate Weight g approx 220 Specific data USB Adapter Model CPA2500 Pressure units mbar bar kPa MPa mmHg psi mH2 switchable depending on sensor selected Recording options start stop conditions pretrigger stop delay Max range Accuracy Measurement period FS 19999 to 19999 digit 0 2 at reference temperature 25 C imsto 10s Measuring rate 1 000 measurements sec PC connection Standard USB plug Type A Transmitter Circular connector 7 pin M16 x 0 75 Power supply via USB port Operating conditions C 25 50 0 95 rel humidity non condensing Reference temperature C 25 Storage temperature C 25 70 Dimensions mm a
47. r ist Da es nach dem Stand der Technik nicht m glich ist Computerprogramme so zu erstellen dass sie in allen Anwendungen und Kombinationen fehlerfrei arbeiten bernimmt WIKA keine Haftung f r die Fehlerfreiheit und den ununterbrochenen Betrieb des Programmes Insbesondere wird keine Ge w hr daf r bernommen dass das Programm den Anforderungen des Anwenders entspricht oder mit anderen von ihm ausgew hlten Programmen zusammenarbeitet Die Verantwortung f r die richtige Auswahl und die Folgen der Benutzung des Programmes sowie der damit beabsichtigten oder erziel ten Ergebnisse tr gt der K ufer Lizenznehmer WIKA haftet nicht f r Sch den au er der Schaden wurde durch grobe Fahrl ssigkeit seitens WIKA verursacht In diesem Falle haftet WIKA f r unmittelbare Personen oder Sachsch den pro Schadens fall bis zum Zehnfachen des Kaufpreises F r andere als die vorgenannten Sch den haftet WIKA nicht Gegen ber Kaufleuten wird die Haftung f r grobe Fahrl ssigkeit ausgeschlossen Dieser Vertrag ist in Kraft bis der Lizenznehmer ihn durch Vernichtung des Programmes samt allen Kopien beendet Dar ber hinaus erlischt er bei Versto gegen die Vertragsbedingungen Der Lizenz nehmer verpflichtet sich bei Vertragsbeendigung das Programm und alle Kopien zu vernichten WIKA ist berechtigt Verbesserungen und Weiterentwicklungen des Programmes nach eigenem Er messen durchzuf hren WIKA Betriebsanleitung Druckmessumformer 17 Druck
48. r templates have V footer picture change to be saved as bmp jpg or icon format By this feature picture size Em must matched before The printout can be extended to an individual form by simple means 5 6 Measurement Diagrams The loaded data of the measuring windows can also be displayed in diagrams Select for this Create new diagram in the menu point Diagram Then a selection of all possible graphs will be displayed Select the desired graphs and acknowledge your selection by pressing Ok The diagram will be opened System limitations maximum 2 different units mbar bar etc per diagram maximum 15 graphs per unit Y axis displays the unit Zoom left right Y axis choose here if the mouse zoom function is to be ap plied to the left or right Y axis fel Diagram au i ll x Aml x ole 2 9 SER HE Zoom back cancels last zoom Change name the diagram here action Diagram 1 can be renamed Add delete labels measuring points can be described see below N Settings 1600 KT Add delete series manual zoom 1500 TK the number of dis grid and colour 1400 Hot played graphs can be settings i Eu pH x CS La changed see below g 199 53 E 1100 H x 1000 ck Zoom all an V L Display points show max en 2 ER a display marking of diagram area D a measuring points re 10 14 3815 es ZU es Z 143630 1 Wees 14 36
49. re served for another even not connected device an error message will appear In principle it is possible that 2 devices are set on the same COM port but then you have to take care that not both devices are connected at the same time because this would lead to a conflict 4 3 Is there an automatic update function that updates the installed driver to the lat est version The driver is not updated automatically lf there is already a suitable for the operating system driver during the installation this driver will be used automatically If the usage of the adapter cause problems please make sure that the latest version of the driver for the adapter is used and install the latest version manually See 6 5 if necessary WIKA Operating Instructions model CPT2500 6 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 4 4 How to find out the used version of the driver Two device drivers are needed to use the adapter Firstly the USB Composite Device for the USB device and the USB to UART Bridge Controller for the supply of the COM port Make sure that the adapter is connected and start the Device Manager Win XP click start settings control panel performance and maintenance system hardware For the USB device driver open the submenu USB controller at the Device Manager open the features for this connection CP210X USB Composite Device by a double click and change then to dri
50. red area hold the left mouse key move the mouse to the end of the desired area and release the mouse key the selected part will be enlarged Zoomed With diagram zoom back the actual area will be set back to the view before With diagram zoom all the whole diagram will be set back to the original view The enlarged view can be moved left right up and down with the scrollbar To show accurate display details we recommend the function diagram settings This function permits to define a section by number and time declaration 5 6 4 Copying Data to Clipboard Diagrams can be copied to the clipboard to insert them in other applications again Click on the required diagram and press the key combination Strg C gt the diagram will be copied to the clipboard as a bitmap WIKA Operating Instructions model CPT2500 13 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft 6 Specification Specific data Pressure transmitter Model CPT2500 Pressure range Over pressure safety Burst pressure Resolution Pressure range bar bar bar mbar 0 1 0 16 0 25 0 4 0 6 1 1 6 SE 6 1 1 5 2 2 5 10 10 i 35 2 2 2 4 2 4 4 8 6 12 12 20 5 42 0 1 1 100 Over pressure range bar 35 200 1200 1500 Burst pressure bar 42 800 2400 3000 Resolution bar 0 01 0 1 Type of pressure Relative pressure absolute pressure 0 25 up to 16 ba
51. rements table Measurements Relative Pressure Average relative pressure 11 mbar Relative Pressure Min 11 mbar 4 Relative Pressure Max 11 mbar Recording not ache current status of the re cording start stop condition Data Sets Ir number of data sets and rst Se period of recording last Sa 5 3 3 Start Recording When recordings are restarted all data which have been recorded before will be delet A ed If necessary read in and save important information or save the data or demand be fore a measurement restart Start New Recording M GOUSB 1000 33000007 Output FF measured vake cycle time 5 ies a ee Start Start Signa r Stat Condition Boers Sivi immediately pra ngge MEREU VUE tant P measured value gt imit 1 wi SO average stat measured value lt imit 2 Da E ety yee WIES stat d measured value gt Init 1 ormeaswed value lt limit 2 C Sat measured value lt imit 1 and measured value gt leng 2 Stop Stop Signal r Stop Condition s Ce measured value marani z C op alter 10 seconds San stop i measured value gt limit 3 asked miima pesk 0 Hop mesured value lt Erit 4 stop i measured value gt imit 3 or measwed value lt limk 4 sop measured value lt imit 3 and measured value gt lime 4 Stop Delay f seconds Start a Cancel WIKA Operating Instructions model CPT2500 Pressure sensor CPT2500 with USB adapte
52. t is possible that the connector does not snap in the jack correctly In this case you have to hold the connector at the bend relief not at the casing Don t plug the connector wedged An accu rate attached jack can be easily plugged in without great effort To disconnect the sensors it is not allowed to pull at the cable In this case you have to hold the connector at its casing 2 3 Zero correction of the pressure sensor OFFS For the measurement a zero offset can be conducted shown vale measured value offset The zero correction in combination with the slope correction see below is mainly used to adjust the devi ation of sensors The entry has to be made in the configuration software The offset information will be stored in the sensor So you can set it individually for each sensor 2 4 Slope correction of the pressure sensor SCAL The measurement s slope can be affected by this factor factor in shown value measured value 1 scale 100 The slope correction in combination with the zero correction see above are mainly used to adjust the deviation of sensors The entry has to be made in the configuration software The scale information will be stored in the sensor So you can set it individually for each sensor 2 5 Pressure connection to the pressure sensor The measuring adapter is conceived that way that all sensors of the CPT2500 series can be connected without new calibration Therefore a multiplicity of
53. than 5ms 200 measured values are possible At a cycle time more or equal than 5ms 50 data sets are possible which are made up of four different series of measurements 50 data sets x 4 series of measurements 200 measuring values Example a cycle time of 10ms is selected There will be 10ms long 50 data sets 500ms recorded before the normal measuring will be started Stop Here it is possible in analogy to the start conditions to set the stop conditions Besides the man ual stop and the measuring stop after a certain time the stop by specified thresholds is available too if these are under or overrun the condition depending on the selected case is fulfilled or not The thresholds entry is carried out in the mask on the right side You even can select which signal shall cause the measuring stop But this is only available when the cycle time is higher or equal than 5ms You can make this entry on the left side under Stop Signal The Stop Delay effects a continuous measurement until the defined time is up After this the measuring will be stopped automatically 5 3 4 Displaying the Measurements To read the measuring values the cyclic recording has to be stopped first After loading the data the values will be shown in the register Data automatically The white fields for the table heading can be edited In the register Comment you can write arbitrary texts If you want to view the data later again you have
54. use of the interface adapter 7 Standard regulations for operation and safety for electrical light and heavy current equipment have to be observed with particular attention paid to the national safety regulations e g VDE 0100 8 When connecting the device to other devices e g the PC the interconnection has to be designed most thoroughly as internal connections in third party devices e g connection of ground with pro tective earth may lead to undesired voltage potentials 9 The device must be switched off and must be marked against using again in case of obvious mal functions of the device which are e g visible damage no prescribed working of the device storing the device under inappropriate conditions for longer time When not sure the device should be sent to the manufacturer for repairing or servicing 10 Warning Do NOT use this product as safety or emergency stopping device or in any other applica tions where failure of the product could result in personal injury or material damage Failure to comply with these instructions could result in serious injury and material dam age JS 1 4 System Requirements IBM compatible PC Pentium At least 20 MB hard disk capacity available CD ROM drive At least 256 MB main memory Windows 2000 XP Vista Windows 7 Mouse One unassigned USB port WIKA Operating Instructions model CPT2500 4 Pressure sensor CPT2500 with USB adapter CPA2500 and USBsoft
55. ver For the COM driver open the submenu Ports COM amp Allgemein Anechlusseinstellungen Treiber LPT open the features for this connection CP210X USB to UART Bridge Controller COM x by double click and change then to driver There you can see the currently used driver version Treiberanbieter Silicon Laboratories Treiberdatum 16 12 2004 Treiberversion 4 28 0 2700 Digitale Signatur Nicht digital signiert 4 5 How to update a driver of an older version or how to uninstall the driver In order to update the driver you have to uninstall the old driver first and install the latest driver after wards 1 Uninstallation of the driver Make sure that the USB adapter is not connected Go to start settings control panel and then double click software Search for the entry CP210X USB to UART Bridge Controller and click then change remove Click yes at the pop up window The driver will now be uninstalled Thus the driver is uninstalled for all corresponding USB adapters 2 Reinstallation of the driver The reinstallation is just the same as an installation the first time Please refer to 5 Software Installation for installing the new driver 5 Operating Software USBsoft2500 USBsoft2500 permits the handling of an USB measuring adapter of the CPA2500 series This adapter enables a direct connection of a pressure sensor type CPT2500 to the USB inter