Home

Labofuge® 200 SERVICE MANUAL

image

Contents

1. keys pressed The accumulated rotor cycles will be displayed in the speed display e Check the condition of the drive motor shaft the centrifuge must not be used any longer if the drive shaft is damaged bend thread is worn out horizontal grooves etc 2 1 1 7 Temperature Level e Check the air inlet underneath the lid and under the bottom plate for free ventilation insufficient air flow will lead to temperature rise of rotor motor and electronic parts 2 1 2 Maintenance Routine after Dismantling the Centrifuge Casing 2 1 2 1 Motor Supporting Elements e Check the supporting and damping elements of the drive motor and replace them in case of increased rubber abrasion or abundance of imbalance but at least every 3 years 2 1 2 2 Braking Circuit e Check the function of the braking circuit even brake effect 2 1 2 3 Lead and Screwing Connection e Check the terminal and plug connections of all leads and on all boards and electrical components tighten all loosen screwing connections refit or replace defective parts e Check the screwing connections of all boards mechanical and electrical components and re tighten them if necessary use screw locking lac for motor mounts and lid lock assembly 2 1 2 4 Protection Earth Core and Grounding Connections e Check the protection earth core for continuity and all grounding plug connectors e Check isolation resistance and accessible current see 2 5 Labofuge 200 eraeus CARR SERVICE eel
2. Beide vorderen und seitlichen Befestigungsschrauben 204 aus Bodenplatte und Kessel herausdrehen e Netzzuleitung von der Hauptplatte Klemme XA abschrauben und Erdungs stecker abziehen e Frontblende hochnehmen um 90 drehen und vor dem Kessel plazieren e Geh use hochdr cken und uber die senkrecht stehende Frontblende und den Kessel nach oben abnehmen e Ger t sinngem in umgekehrter Reihenfolge montieren Ausgabe Edition 02 16 01 02 AH AUSBAUANLEITUNG DIASSEMBLY OF INSTUMENT PARTS 5 1 esKendro The index numbers stated in reappear within the breakdown drawings and the spare part lists Dismantling the Housing 5 1 1 Front panel 102 e Pull out the mains plug and place the instrument to the rear for the wide of the front panel e Unscrew both screws type Ejot 101 at the lower rim of front panel use a small Phillips screw driver e Pull the panel s lower rim a little to front but no more than 15 to avoid the braking off of the plastic hooks at the upper rim e Push the front panel in this position to the top to unlock it s casing connection and depose the panel in front of the unit e Reassemble the front panel analogously in reverse order and press the lower rim tight to the casing when refitting the Ejot screws but don t tighten the Ejot screws too much to avoid an overscrewing of the casing s plastic thread 5 1 2 Lid 210 e Open the lid and pull out the mains plug e Unscrew both threaded hing
3. amp clearance Pre run Checks O Line voltage V AC Display segments on power up Function Keys Door interlock and latch Drive stop amp Door unlatch 50 rpm O O OO Mechanical O Motor bearings O Antivibration mounts O Motor rubber flange O Chamber sealing Revised 16 01 02 lof2 Kendro service Information Comments S R Signature Date Revised 16 01 02 2 of 2
4. 11 2 x 14 8 Approx 10 7 23 5 Approx 10 7 23 5 Dimensions H x W x D mm inch Weight incl rotor kg Ibs Power consumption W 65 65 ORDER NUMBERS Model Order No Labofuge 200 230 V 50 60 Hz 75003630 110 120 V 50 60 Hz 75003631 Controller Microprocessor controller for time and speed Drive Brushless induction motor microprocessor controlled Runtime 1 99 min and continuous operation Hold Program memory Stores values last entered unlimited Safety Lid lock and lid interlock steel armoured guard ring Design Fibre glass reinforced polyamide housing with high noise and Accessories for Labofuge 200 230 V version 110 120 V version Angle rotor 75003760 75003760 Max speed rpm 5300 5000 Max RCF x g 3030 2600 Max capacity ml 12x15 12X15 Max radius cm 9 65 9 65 Acceleration time sec 40 40 With the start button repeat Braking time sec 45 45 runs can easily be recalled Accessories for angle rotor 75003760 Tube volume Type of tube Dimension mm Tubes Type of Adapter mi Diam x Length per rotor adapter Order No 7 Glass tubes DIN 12 100 12 yellow 75003227 15 Glass tubes DIN 16 100 12 2 _ 3 5 VenoJect Il Terumo 13 15 12 cream 75003227 rubber pad 7 VenoJect Il Terumo 13 100 12 yellow 75003227 9 10 VenoJect Il Terumo 16 100 12 sleeves 75003763 3 5 Vacutainer BD 13 75 12 cream 75003227 rubber pad 7 Vacutainer BD 13 100 12 yellow 7500322
5. Beginning with low frequency and small pulse width blocks both parameters will be increased up to the operators set speed The set speed value will be reached with a tolerance of 5 within the valid mains voltage range 3 2 3 Micro controller Central Processing Unit The controller block includes the central processor unit CPU 87C51 and the data storage NV RAM 9346 The ROM which contains the controlling program is integrated in the CPU The most important operating parameters e g the maximum speed or the last operator settings are stored in the non volatile NV RAM 3 2 4 Key and Indication Board The key and indication board is part of the main board The connection to the main board is done by a 14 polar flat cable The 7 segment displays the control key LED s and the operating keys are managed by the CPU in multiplexing process For the setting procedures serves MEGACONTROL simple see Instruction Manual Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN Ken dro CARR BREAK DOWN DRAWINGS Hauptplatte Controller Tasten und Anzeigenteil Main Board Controller Key and Indication Part NV RAM p XF Hauptplatte Leistungselektronik Main Board Power Electronics E A F2 Netz mains Legende legend Deckelschalter Entriegelungsspule Phasen Lid Switch Unlocking Solenoid Kondensator Lotverbindung solder connection i Mot on otor Im Steckverbindung plug connect
6. Fe ee r INEN sames All not marked Diodes LL4148 S S ot VA v21 N F1 L1 GND Netz SI 6 25AT 5 6mH S EEN Mains L1 GE R1 re S SI re RER x ed N 2 2 4 D l DI 11 E T120V 10V c10 BVEI38 12 0044 003 2n2 C7 PE1 Y ch SMD o GND o GND Ausgabe Edition 02 15 01 02 AH GND Schaltbild Hauptplatte 178 120V Leistungsteil Wiring Diagram Main Board 178 120V Power part 4 11 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN e ii CARR BREAK DOWN DRAWINGS e Kendro D10 H1 H2 H3 H4 H5 nn VCC HDSP 5551 HDSP 5551 HDSP 5551 HDSP 5551 HDSP 5551 vcc A R47 R54 8x4k7 SMD R39 R41 D13 R59 SMD GND 74HCT540 R42 R45 C16 22p SMD nii SMD 8x220R SMD See E 18 A P0 1 PO 2 J 11 14112 P0 3 P0 4 P0 5 P0 6 PO 7 P2 0 P2 1 P2 2 P2 3 P2 4 P2 5 P2 6 P2 7 D12C N l ko RL N v33 ZN v34 ZN vs ZN vss ZN var ZN vas ZN v39 WR DO D1 D2 D5 D6 D7 D3 H6 HDSP 5551 H7 HDSP 5551 ALE PALE TXD RXD PROG 0474 R30 029 7 x RAFI TASTER 1 4k7 33pF 3 SMD O D12A vcc vcc 74HCOO Verbindungskabel Connection cable Alle nicht bezeichneten Dioden LL4148 All not marked Diodes LL4148 GND UNW p C28 100n SMD VCC VDD i i GND GE C23 C24 C25 Bauteile nicht bestueckt C27 Components not placed 100n SMD GND Ausgabe Edition 02 Schaltbild Hauptplatte 178 120V Bedien Anzeigenteil Wiring D
7. and secure them with locking lac Reassemble the device in reverse order Perform a test run and check the sense of rotation see imprinted arrow direction on casing 5 3 2 Motor supports 316 All 3 rubber supports 316 have to be replaced at the same time and at least every three years By the way the 6 double sided sandpaper discs 315 must be exchanged too Unscrew the drive motor see 5 3 1 hold it with one hand and lay the armored chamber together with motor onto the side Pull the motor from the supports and lay it carefully onto the side Remove the 3 screws 224 from the bottom plate and take out the rubber supports together with sand paper discs 315 Install the new rubber mounts together with new sandpaper disks put the lock washers in place tighten the screws evenly and secure them with screw locking lac Put the unit again onto it s feet mount sandpaper disc motor and lock washer and tighten the 3 nuts evenly by use of a torque key 5 Nm and secure them with screw locking lac Reassemble the device in reverse order At last perform a test run Labofuge 200 SORVALL 3 Heraeus AUSBAUANLEITUNG eKendro CARR DIASSEMBLY OF INSTUMENT PARTS 5 4 Ausbau mechanischer Komponenten 5 4 Replacement of Mechanical Components 5 4 1 Deckelschlosser 300 5 4 1 Lid Lock Assemblies 300 ACHTUNG ATTENTION Beide Deckelschl sser inklusive der Mikroschalter sind zu einem Ersatzteil zusammengefa t und k nnen daher nicht einzeln be
8. den Routineeinsatz m wartungsfreier Induktionsmotor lt Die medizinische Kleinzentrifuge Wartunggsfrei Die Labofuge 200 ist mit einem b rstenlosen Motor ausger stet so dass ein Auswech seln der Kohleb rsten entf llt Neben der Zeit und Kostenersparnis sind damit auch saubere Arbeitsbedingungen gew hrleistet Vielf ltiges Zubeh r Die Labofuge 200 wird als komplettes Set geliefert einschlie lich autoklavierbarem Rotor Aus schlagz hem glasfaserverst rktem Kunststoff gefertigt besitzt dieser Rotor eine hohe Stabilit t und ausgezeichnete Laufeigenschaften Er kann einfach und schnell entnommen und in der Labor Sp lmaschine gereinigt werden Eine gro e Auswahl von Adaptern erm glicht das Zentrifugieren aller blichen Quality Products Lifetime Care R hrchen mit 5 7 10 und 15 ml einschlie lich der vielfach verwendeten Blutabnahmegef e Monovette Vacutainer und Venoject F r Glas r hrchen ist eine spezielle Schutzh lle vorgesehen die bei einem Bruch Splitter und R hrcheninhalt auff ngt Sicherheit Im heutigen Laborbetrieb bergen die eingesandten Proben oftmals unbekannte Risiken Der Benutzer einer Zentrifuge muss sich daher vor m glicherweise gef hrlichen Aerosolen sch tzen die beispielsweise durch R hrchenbruch freigesetzt werden k nnen Die Labofuge 200 l st dieses Problem durch effektive Abdichtung der gesamten Rotorkammer w hrend des Zent
9. mit einer Hand festhalten und Kessel mit Motor vorsichtig auf die Seite legen Motor von den Gummipuffern ziehen und vorsichtig auf die Seite legen 3 Befestigungsschrauben 224 unter der Bodenplatte abschrauben und die Gummipuffer mitsamt den Schleifscheiben 315 entnehmen Die neuen Gummipuffer mit neuen Schleifscheiben einbauen Sperrkantringe aufstecken Schrauben gleichm ig festziehen und mit Schrauben Sicherungs lack sichern Ger t wieder auf die F e stellen Schleifscheiben und Antriebsmotor von oben auf die Puffer schieben Sperrkantringe aufstecken Muttern mit Dreh momentenschl ssel 5 Nm festziehen und mit Schrauben Sicherungslack sichern Ger t sinngem in umgekehrter Reihenfolge wieder zusammenbauen Anschlie end einen Testlauf durchf hren Ausgabe Edition 02 16 01 02 AH 5 3 Heraeus AUSBAUANLEITUNG DIASSEMBLY OF INSTUMENT PARTS Ausbau von Antriebskomponenten Antriebsmotor 310 ersetzen 5 3 1 e Kendro Replacement of Drive Components Disassembly of Drive Motor 310 Remove the casing see 5 1 3 Disconnect the motor leads from terminal XC and pull off the plug connectors from the capacitor 327 Take the leads out of the cable holder 308 Unscrew the 3 nuts 313 and remove them together with the lock washers 314 Lift the motor out of the rubber mounts and remove the motor from the bottom plate Reassemble the motor analogously in reverse order and tighten the 3 nuts with use of torque key 5Nm
10. the base ground table lorry with lockable wheels etc For resonance free and stable conditions e Check for a well ventilated place and sufficient distances to walls or adjacent equipment without exposure to direct sunlight e Check the leveling of instrument use a spirit level 2 1 1 3 Lid Locking Mechanism and Safety e Connect the centrifuge to power and switch ON e Check for easy lid closing and self acting lid opening if in disorder readjust lid s swivel hinge and or lock assembly e Check the central rubber gasket for lid sealing and replace it if damaged e For checking the safety start the centrifuge let it shortly run and stop it the lid must not be unlocked by the microprocessor until the end message is shown on the display if safety circuit is out of function replace the main board 2 1 1 4 Cleanliness of Spin Chamber and Motor Casing e Open the lid and remove the rotor for loosening turn the central winged nut anti clockwise from the motor shaft e Clean the spin chamber with a dry and absorbent cloth remove all dust and moisture see also 2 5 Cleaning e Check the cleanliness of the motor casing and take care of the annular slot around the motor shaft penetrating fluids can damage the upper motor baring remove fluids with an injector and or absorbent paper 2 1 1 5 Rotor and Accessories Condition and Sealing e Check the condition of rotors and accessory parts especially all supporting or stressed partit
11. 0 120V 10 15 50 60HZ to Serial No Text SCREW 3X14 FRONT PANEL KEY FOIL SEAL FOAM RUBBER MAINBOARD 120 V SCREW 3X8 NV RAM CLINIFUGE FUSE 6 25 A SLOW WASHER SCREW 3X8 SCREW M5 X 8 HOUSING SEAL BUSHING SEALING LID WINDOW COLLAR SPRING WASHER SCREW O RING 4 47 X 1 78 BOTTOM PLATE ARMED BOWL SECURING WASHER SCREW M6 X 12 WIRE CLOTH WASHER A 4 3 ALLEN SCREW M4 X 6 WASHER FOOT SCREW M4 X 16 FAN WASHER A 4 3 DOUBLE CONNECTOR MALE HEXAGONAL NUT M4 LID LOCK ASSY CPL SCREW 4X10 SCREW M4X16 SCREW Seite 1 Spare Part List 75003631 OI from Serial No Index 00308 00310 0031 1 00313 00314 00315 00316 00322 00323 00324 00325 00327 00330 00331 Donnerstag 17 Januar 2002 Partno 20220416 20210275 20020738 20420070 20480251 10104080 20022874 20480130 20190194 20220569 20480244 20540344 70901069 20053358 Kendro Laboratory Products Plant Osterode LABOFUGE 200 120V 10 15 50 60HZ to Serial No Text CABLE CLIP MOTOR MOTOR COVER NUT M6 SECURING WASHER WASHER SAND ANTIVIBRATION MOUNT WASHER 4 3 MAINS CABLE CLIP LOCK WASHER CAPACITOR SERVICE KIT CLINIFUGE MEDIFUGE ROTOR NUT Seite 2 Kendro Service Information Heraeus Zentrifugen Vorbeugende Wartung Checkliste Rotor Inspektion O Allgemeine Sichtpr fung O Befestigungsmutter O Verfallsdatum Rotor O Stand des Zykluszahlers Allgemeinzustand O Geh use sauber unbe
12. 00 Fax 49 6181 35 59 44 info kendro de Asien Pazifik Kendro Laboratory Products H K Limited Hong Kong Tel 852 2711 3910 Fax 852 2711 3858 info kendro com USA Kanada Lateinamerika Kendro Laboratory Products International Sales Newtown Tel 1 203 270 2080 Fax 1 203 270 2210 info kendro com Internet http www kendro de Kendro Laboratory Products Ein internationales Unternehmen hervorgegangen aus der Fusion von Heraeus Instruments und Sorvall F r Kontakte mit weiteren internationalen Niederlassungen setzen Sie sich bitte mit der internationalen Vertriebsorganisation von Hanau Hongkong oder Newtown in Verbindung Abweichungen von den in dieser Information enthaltenen Abbildungen und technischen Daten bleiben vorbehalten Printed in Germany 3C 01 00 VN 4t K nzel ZF LF200 3d LABOFUGE 200 COMPACT CENTRIFUGE Easy to Use The Heraeus Labofuge 200 is functional and sophisticated with an ergonomic design It is ideal for use in medical practices clinical and small laboratories and as a stand by unit in large laboratories Maintenance free The Labofuge 200 is equipped with a brushless motor so there is no need to replace carbon brushes Beside saving time and money this also ensures clean operating conditions Accessories The Labofuge 200 comes complete with an autoclavable rotor Made of impact resistant fibre glass reinforced polyamide this rotor offers high stability an
13. 07 GU 00327 20540048 KONDENS MAB M8 6 400 6UF 00330 70901001 SERVICE KIT LABOFUGE 200 00331 20053358 KNEBELMUTTER FUER 3760 Donnerstag 17 Januar 2002 Seite 2 Spare Part List 75003630_01 from Serial No Index 00101 00102 00103 00105 00110 00111 00112 00113 00121 00122 00204 00205 00206 00207 00208 00210 00211 00212 00213 00214 00215 00221 00222 00223 00224 00225 00226 00227 00232 00233 00234 00235 00236 00237 00300 00304 00305 00307 Donnerstag 17 Januar 2002 Partno 20460133 20022598 20022604 20290521 20150103 20460137 70901052 20230145 20250031 20460132 20460088 20020726 20020717 20220561 20290473 70020819 20050543 20350211 20480250 20037565 20290419 70022871 70022870 20480251 20430216 20022867 20480224 20460092 20480157 20049932 20460112 20480108 20220510 20420076 20003620 20460138 20440295 20022873 Kendro Laboratory Products Plant Osterode LABOFUGE 200 230V 10 50 60HZ to Serial No Text SCREW 3X14 FRONT PANEL KEY FOIL SEAL FOAM RUBBER MAINBOARD SCREW 3X8 NV RAM LABOFUGE 200 NEW FUSE WASHER SREW 3 5 X 8 SCREW M5 X 8 HOUSING SEAL BUSHING SEALING LID WINDOW COLLAR SPRING WASHER SCREW O RING 4 47 X 1 78 BOTTOM PLATE ARMED BOWL SECURING WASHER SCREW M6 X 12 WIRE CLOTH WASHER A 4 3 ALLEN SCREW M4 X 6 WASHER FOOT SCREW M4 X 16 FAN WASHER A 4 3 DOUBLE CONNECTOR MALE HEXAGONAL NUT M4 LID LOCK 230V
14. 2 16 01 02 AH AUSBAUANLEITUNG DIASSEMBLY OF INSTUMENT PARTS esKendro 5 2 Replacement of Electrical Components 5 2 1 Fuses on Main Board 113 replacement e Dismantle the front panel see 5 1 1 e Check the micro fuses and if necessary replace them by equivalent and undamaged parts e Perform a test run and search for blowing cause Reassemble the device analogously in reverse order 5 2 2 NV RAM on Main Board 112 e Dismantle the front panel see 5 1 1 e ATTENTION CMOS components Discharge your body before handling Notice correct position of NV RAM 8 pins and pull carefully out of socket Reinsert the new NV RAM correctly e Reassemble the device analogously in reverse order reconnect it to power and perform a test run 5 2 3 Main Board Replacement 110 ATTENTION The key and indication board is part of the main board and cannot be ordered separately e Dismantle the front panel see 5 1 1 e Disconnect plug connections for lid switches XB protecting earth conductor PE and unscrew the lines for lid solenoid XD motor XC and mains supply XA e Remove all screwing of the main and indication board Ejot type 111 and 122 with fiber washers 121 and take out both boards e Touch a grounded receptacle to discharge your body before touching the sensitive CMOS components Take a new NV RAM 112 out of box or re use the old but trouble free component and insert it into the socket of the new main board if necessary remove a pla
15. 2 AH 4 7 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN e ii CARR BREAK DOWN DRAWINGS e Kendro D10 H1 H2 H3 H4 H5 nn VCC HDSP 5551 HDSP 5551 HDSP 5551 HDSP 5551 HDSP 5551 vcc A R47 R54 8x4k7 SMD R39 R41 D13 R59 SMD GND 74HCT540 R42 R45 C16 22p SMD nii SMD 8x220R SMD See E 18 A P0 1 PO 2 J 11 14112 P0 3 P0 4 P0 5 P0 6 PO 7 P2 0 P2 1 P2 2 P2 3 P2 4 P2 5 P2 6 P2 7 D12C N l ko RL N v33 ZN v34 ZN vs ZN vss ZN var ZN vas ZN v39 WR DO D1 D2 D5 D6 D7 D3 H6 HDSP 5551 H7 HDSP 5551 ALE PALE TXD RXD PROG 0474 R30 031 7 x RAFI TASTER 1 4k7 33pF 3 SMD O D12A vcc vcc 74HCOO Verbindungskabel Connection cable Alle nicht bezeichneten Dioden LL4148 All not marked Diodes LL4148 GND UNW p C28 100n SMD VCC VDD i i GND GE C23 C24 C25 Bauteile nicht bestueckt C27 Components not placed 100n SMD Ausgabe Edition 02 Schaltbild Hauptplatte 28 230V Bedien Anzeigenteil Wiring Diagram Main Board 28 230V Key and Indication part 15 01 02 AH 4 8 Labofuge 200 SORVALL Heraeus CARR EXPLOSIONSZEICHNUNGEN BREAK DOWN DRAWINGS Kendro Laboratory Products a uge D DS DE D2 D7 N N S gt 4 gt gt gt V17a V22a V19a Ausgabe Edition 02 15 01 02 AH S08 008 0 o Oo gt gt Q F cl J D13 O V37 o Gig ZUR o lt and N eels I UUU Og 9 det TE p T
16. 7 7 Vacutainer BD 16 15 12 sleeves 75003763 rubber pad 75003266 10 Vacutainer BD 16 100 12 3 15 Vacutainer BD 16 125 6 S 4 Sarstedt Monovette Ines 83 5 12 cream 75003227 5 Sarstedt Monovette 13 90 12 cream 75003227 7 5 Sarstedt Monovette 15 92 12 3 9 Sarstedt Monovette 16 5 92 6 rubber pad 75003762 12 Urine Sarstedt Monovette 16 5 101 5 6 3 Urine tubes BD Terumo 16 100 12 sleeves 75003763 1 included with centrifuge 2 tube incl Hemoguard cap 9 included with rotor The adapter set 75003227 will contain the yellow and cream adapters and rubber pads For Ordering or Technical Information Asia Pacific Kendro Laboratory Products H K Limited Hong Kong Tel 852 2711 3910 Fax 852 2711 3858 info kendro com Europe Middle East Africa not necessary Kendro Laboratory Products International Sales Hanau Germany Tel 49 6181 35 300 Fax 49 6181 35 59 44 info kendro de Latin America Kendro Laboratory Products International Sales Newtown USA Tel 1 203 270 2080 Fax 1 208 270 2210 info kendro com USA Kendro Laboratory Products Newtown Tel 1 800 522 7746 Fax 1 203 270 2166 info kendro com amp Internet http www kendro com g esKendro T S Laboratory Products Quality Products Lifetime Care eraeus GE Registered to ISO 9001 Kendro Laboratory Products meet or exceed stringent quality and product safety standards CE for the European Union and UL
17. BREAKDOWNDRAWINGS Ss Kern Hauptplatte Main Board PE Net F1 F2 PE Wee 6 25AT N 6 3AT bl SW blue black Sdu chutzleiter BI Phasenschieber protective BLK Kondensator gn conductor green Sw m BLK oe Erdungstecker m GRN YEL phase shift L Deckelschalter Deckelmagnete grounding plug terminal _ BAA capacitor S1 S2 Y1 Y2 zz J lid switches lid solenoid Bodenplatte base plate of armored housing 2x F cherscheibe 2x fan washer 4 3 2x Mutter 2x nut M4 MOTOR Netzkabel mains cable Ausgabe Edition 02 Klemmplan Wiring Diagram 15 01 02 AH 4 4 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN ZK ndro CARR BREAK DOWN DRAWINGS Kerer o Laboratory Products a EEE EE S x 20 pg SI IS Ir dp C32 fi xG CG ale C1 x l D A L1 C2 St V3a V gt D Da 06 D2 D7 Ge S hl Ge cu p A C Sb UBB Re p Ridw F R117 1 e gt J R27 V1 ES LJ Q S A m v8 x Io V19 5588 u gt OI a UUgS N I Kir ZS Gm N Vil 5 iJ z d N N ia PRIM LJ l mM N S S Q z z x vg V17a V22a VIe a __ gt RY a SE u Se les O ee X Motor x EEE C R9 x a Deckelschalter x Deckelschloss e Ausgabe Edition 02 Best ckungsplan Haupiplatte 28 230V Component Plan Main Board 28 230V 15 01 02 AH 4 5 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN et 1 ee CARR BREAK DOWN DRAWINGS esKenc ro Leistungsteil Bedien Anzeigenteil Power part Key a
18. DM S HAUPTPLATTE 28 230V GS VERSIO EJOT PT KB 030X008 SCHR LINS KR EE PROM LABOF 200 220V 1052V03 SICHERUNG FEIN 6 3 A T 5X20MM SCHEIBE 045X100X1 0 FIB EJOT PT KA 035X008 SCHR LINS KR D7985 050X008 SCHR LINS KR VA GEHAEUSE F MEDIFUGE DICHTUNGSPROFIL F MEDIFUGE SCHNAPPDURCHF HRUNG D19MM TESAMOLL 741 DECKEL RAL9002 BEDR CAUT 2 5M SICHTFENSTER GLEITLAGERBUCHSE 8X10X5 FORU D0137 FEDERSCHEIBE A8 FLACHKOPFSCHRAUBE M ANSATZ O RING 0004 47X01 78 VITON GU BODENPLATTE 4 MM PANZERKESSEL GEBOGEN 4 MM FEDERRING DIN 128 A6 1 4310 D0933 060X012 SCHR SKT VA DRAHTGEWEBE 0 5 MW0 8 60X60 D9021 043 SCHEIBE VA D7985 040X006 SCHR LINS KR VA D0125 064 SCHEIBE VA FUSS D7985 040X016 SCHR LINS KR VA D6798 043 SCHEIBE F VA FLACHSTECKER 6 3X0 8MM 07F210 D0934 040 MUTTER SKT VA SCHLOESSER VOLLST 230V EJOT PT KB 040X010 SCHR LINS KR D0965 040X016 SCHR SENK KR VA FLACHKOPFSCHRAUBE F KLEINZE KABELCLIP MOTOR 211 30 220V 50HZ MEDIF GUMMIFLANSCH F MOTOR MEDI BI D0934 060 MUTTER SKT VA FEDERRING DIN 128 A6 1 4310 DOPPELS SCHLEIFSCHEIBE 7X25 Seite 1 Ersatzteil Liste Kendro Laboratory Products Werk Osterode 75003630 01 LABOFUGE 200 230V 50 60HZ von Fabriknr bis Fabriknr Index Artikelnr Text 00316 20022874 GUMMIPUFFER RD 14X30 TAlLLIER 00322 20480130 D0125 043 SCHEIBE VA 00323 20190169 NETZKABEL 3X1 MM EU 00324 20220569 BEFESTG SCHELLE F 9 5MM KABE 00325 20480244 FEDERRING DIN 128 A4 1 4310 00326 20290189 KNICKSCHUTZTUELLE HV 21
19. Kendro 2 2 Fehlersuchplan 2 2 Trouble Shooting Anzeige mogliche Error Possible Error a Error Cause Corrective Procedure Verhalten Fehlerquellen Indication Source Netzsicherung Sicherung berpr fen und ggf Mains fuse or circuit Check fuse or circuit breaker ausgefallen wieder einschalten breaker failed replace or switch on again No mains E A EEE Check instrument cord voltage replace defective parts supply Replace it if fuse blows again disconnect electrical parts Fehlende Wetkabeldeiekt Netzkabel berpr fen und ggf Netzspan ersetzen nung Defective unit fuse or Displays fuses on main board Ger tesicherung F1 Sicherung austauschen bei Displays bleiben oder F2 auf der erneutem Ausfall die remain otherwise replace main board dunkel Hauptplatte defekt Haupiplatte ersetzen dark Faulty connection Check connections on CPU Defekte Verbindung Verbindungsleitungen Nolan from indication to indicat Board and connecting voltage supply Faulty indication or Hauptplatte komplett ersetzen power board Keine Nieder zwischen Anzeigen berpr fen ggf Hauptplatte power board leads replace defective parts spannungs und Leistungsteil komplett ersetzen versorgung Defekter Anzeigen oder Leistungsteil Motor Motor over bertempera Motortemperatur Ihermosch lter Im Moio temperature Motor temperature is turschalter gr er als 120 C Ee Sa switch has higher than 120 C hat ausgel st gang p tripped R B Leichtg n
20. Motor Gummipuffer verst rkter Gummiabrieb Unwuchth u figkeiten Ersatz bei schlechtem Zustand oder sp testens nach einem Zeitraum von 3 Jahren 2 1 2 2 Bremsschaltung e Bremsfunktion berpr fen gleichm iger Bremseffekt 2 1 2 3 Leitungen und Schraubbefestigungen e Schraub und Steck Anschl sse aller Leitungen an s mtlichen Leiterplatten und Bauteilen auf guten Kontakt hin berpr fen und ggf korrigieren bzw defekte Teile ersetzen e Alle Schraubverbindungen s mtlicher Leiterplatten sowie mechanischer und elektrischer Bauteile auf festen Halt hin berpr fen und ggf korrigieren bzw defekte Teile ersetzen Schraubensicherungslack verwenden 2 1 2 4 Schutzleiter und Erdungsverbindungen e Schuizleiter und alle Erdungsverbindungen auf Durchgang pr fen e lsolationswiderstand und K rperstrom messen Ausgabe Edition 03 18 04 02 AH esKendro Servicing Schedule 2 1 1 6 Rotor Fixing and Motor Shaft e Check the trouble free condition of the locking nut and replace it in case of malfunction e High performance rotors made of plastic have a limited service life Due to safety reasons they have to be exchanged after 10 000 cycles or after being in use for five years The expiry date can be seen on the date clock in the rotor lower shell The two digit number in the middle represents the year and the arrow points to the expiry month The number of cycles may be checked at any time by closing the lid and keeping both set
21. SCREW 4X10 SCREW M4X16 SCREW Seite 1 Spare Part List Kendro Laboratory Products Plant Osterode 7500363001 LABOFUGE 200 230V 10 50 60HZ from Serial No to Serial No Index Partno Text 00308 20220416 CABLE CLIP 00310 20210275 MOTOR 00311 20020738 MOTOR COVER 00313 20420070 NUT M6 00314 20480251 SECURING WASHER 00315 10104080 WASHER SAND 00316 20022874 ANTIVIBRATION MOUNT 00322 20480130 WASHER 4 3 00323 20190169 MAINS CABLE 00324 20220569 CLIP 00325 20480244 LOCK WASHER 00326 20290189 CABLE SHEATH 00327 20540048 CAPACITOR 00330 70901001 SERVICE KIT LABOFUGE 200 00331 20053358 ROTOR NUT Donnerstag 17 Januar 2002 Seite 2 Spare Part List 75003631 OI from Serial No Index 00101 00102 00103 00105 00110 00111 00112 00113 00121 00122 00204 00205 00206 00207 00208 00210 00211 00212 00213 00214 00215 00221 00222 00223 00224 00225 00226 00227 00232 00233 00234 00235 00236 00237 00300 00304 00305 00307 Donnerstag 17 Januar 2002 Partno 20460133 20022598 20022604 20290521 20150178 20460137 70901066 20230189 20250031 20460137 20460088 20020726 20020717 20220561 20290473 70020819 20050543 2035021 1 20480250 20037565 20290419 70022871 70022870 20480251 20430216 20022867 20480224 20460092 20480157 20049932 20460112 20480108 20220510 20420076 70003621 20460138 20440295 20022873 Kendro Laboratory Products Plant Osterode LABOFUGE 20
22. SORVALL raeu Hereus e2Kendro Labofuge 200 SERVICE MANUAL P N 12003630 SORVALL Heraeus INHALTSVERZEICHNIS 1 JL BETRIEBSANLEITUNG nicht Teil dieses Manuals LI Prospekt 0 lb DT RE WEE es WE 2 SERVICE epes 21 Wartungsplan 22 22 Fehlersuchplan 8 23 MeRpunkte SS e 26 24 Reinigung DT 25 Endprifung 2 ET EEE ERBE Eh a ee _ mem 3 1 JI Allgemeine Beschreibung der Baugruppen 31 3 2 Funktionen derHauptplate TT 31 2 nn EEE E 4 SCHALTPLANE i woa4 4 1 Blockschaltbild AT 42 Stromlaufplan TT Can 43 Klemmplan LA 4 4 Best ckungsplan Hauptplatte 22230 V TT 45 4 5 Schaltbild Hauptplatte 282300 VD 468 4 6 Best ckungsplan Hauptplatte 7812002734 49 4 7 Schaltbild Hauptplatte 781200 V TT 4101 E NEE BE 5 _ AUSBAUANLEITUNG rr Labs 5 1 Gehauseteile TT CT 152 Elektrische Komponenten TT 52 5 3 Antriebskomponenten TT Ja 5 4 Mechanische Komponenten Ur 54 5 5 Service Kit TT 5S Ss rs NEE ee 6 ERSATZTEIL ABBILDUNGEN UND LISTE 62 Ersatzteil Liste o BEE EEE BE H 7 1 Vorbeugende Wartung Checkliste O3 RE EE DE NG 8 ANDERUNGSNACHRICHTEN IT Ausgabe Edition 02 18 01 02 AH SERVICE esKendro TABLE OF CONTENTS Title Doc No Page 1 OPERATING INSTRUCTIONS not part of this manua Brochure Lab Brochure EEE EOSS es EE me 2 1 Servicing Schedule 2 2 2 2 Troub
23. assemblies completely with rubber base plates Reinstall the new lid lock assemblies analogously in reverse order and secure the thread of all upper fixing screws 305 with Loctite 221 Reassemble the device in reverse order Check the de correct closing and self acting opening functions after the correct installation and replace the rubber profile 206 Labofuge 200 SORVALL Heraeus 5 5 Service Kit f r Labofuge 200 Medifuge 200 In diesem Service Kit sind alle Teile enthalten die nach Ablauf von 10000 Arbeitszyklen auszutauschen sind Das Kit enth lt unter anderem verschiedene NV RAM s die fur die Verwendung mit dem entsprechenden Steuerprogramm Mikrocontroller Bezeichnung auf der betreffenden Hauptplatte vorgesehen sind ACHTUNG Bei einem Austausch der Teile mu unbedingt auf die richtige Variante der betreffenden Labofuge Medifuge 200 geachtet werden Ein falsch eingesetztes NV RAM kann zur Zerst rung der Hauptplatte f hren AUSBAUANLEITUNG DIASSEMBLY OF INSTUMENT PARTS esKendro 5 5 Service Kit for Labofuge 200 Medifuge 200 This service kit includes all parts which have to replaced after termination of 10000 cycles The kit includes different NV RAMs which are destinated for the use of the referring control program signification of micro controller No on the specific main board ATTENTION When changing the NV RAM it is absolutely necessary to insert the right one into the main board with the right micro control
24. bis end Meldung manually can only be used at termination of br phase until erscheint during run standstill end message appears Deckel wurde Verbotener Eingriff manuell ge Not ffnung nur im ffnet Stillstand bet tigen Lid LIid k Stromkreis message Protection Anzeige im f r Dreh m Deckelschalter oder Leitungen zum Deckelschalter Umrichterver ee A zahlfeld SOUN Leitungen zeitweise pr fen bei defektem gung unterbrochen Mikroschalter Deckelschlo w hrend des interrupted PE STEEN Wackelkontakt komplett austauschen during the brochen run appearsin circuit 15V speed for lid control display was Defective micro Check leads and connectors switch or leads or to micro switch in case of a connectors to micro faulty micro switch replace lid switch are interrupted lock device completely OPEn 15V Strom KE EE Leitungen Schalter pr fen OPEn 15V supply Defective micro Anzeige Kreis im enden bei defektem Mikroschalter message circuit is switch or leads or im Dreh Stillstand H Deckelschlo komplett in speed interrupted at connectors to micro zahlfeld unterbrochen En SIDIOENEN austauschen display standstill switch are interrupted br Gerat kommt br Rotor comes Anzeige ungebremst kurzzeitige Stillstand des Rotors ca 75 patna to standstill Short interruption of Wait for rotor standstill appr im Dreh zum Netzunterbrechung sek abwarten neu Starten pP without mains supply 75
25. cUL or u CSA standards for North America 2000 Kendro Laboratory Products All Rights Reserved Printed in Germany 15C 03 00 VN 4t K nzel N eracus SERVICE eeKendro 2 1 Wartungsplan j hrliche Durchf hrung empfohlen 2 1 Servicing Schedule yearly procedure recommended 2 1 1 RoutinemaBige Wartung ohne Zerlegung der Zentrifuge 2 1 1 Maintenance Routine without Dismantling the Centrifuge 2 1 1 1 Elektrische Installations und Sicherheits berpr fung e Netzstecker ziehen Spannungsversorgung und Netzabsicherung berpr fen 16 A K Sicherungsautomat e Stecker und Steckdose berpr fen defekte Teile ersetzen lassen e Zustand des Netzkabels berpr fen und ggf ersetzen 1 2 Anforderungen an den Aufstellort e Unterbau Fu boden Tisch Rollwagen mit Feststellr dern o auf vibrations freien und stabilen Zustand hin berpr fen e Stellplatz auf gute Bel ftung und gen gendem Abstand zu W nden oder be nachbarten Ger ten hin berpr fen direkte Sonneneinstrahlung vermeiden e Zentrifuge waagerecht ausrichten z B mit einer Dosenlibelle 1 3 Deckel Verriegelungsmechanismus und Sicherheit e Zentrifuge mit elektrischer Spannung versorgen e Festes Schlie en und selbstt tiges ffnen des Deckels berpr fen Korrektur durch Einstellung des Deckels und oder des Deckelschlosses e Deckel Dichtungsring berpr fen und im Schadensfall austauschen e Zur berpr fung des Sicherheit Zentrifuge starten kurz laufen lassen
26. ced but non programmed NV RAM before e Place the parts of the new board correctly and mount it with all screws and fibre washers e Before assembling the front panel check the trigger function of all keys and correct the board mounting if necessary e Do not mix up disconnected cables during re connection e Reassemble the device in reverse order and perform a test run making sure the drive turns in the right direction see imprinted arrow on rim of rotor chamber Labofuge 200 9 3 5 3 1 Kl SORVALL Geh use demontieren siehe 5 1 3 Die Motorleitungen am Anschlu XC abklemmen sowie die Flachstecker am Kondensator 327 abziehen Leitungen aus der Kabelhalterung 308 freilegen Die 3 Muttern 313 abschrauben und zusammen mit den Sperrkantringen 314 entnehmen Motor aus den Gummilagern heben und entnehmen Antriebsmotor sinngem in umgekehrter Reihenfolge wieder einbauen und die 3 Befestigungsmuttern mit einem Drehmoment von 5Nm anziehen und die Muttern anschlie end mit Schrauben Sicherungslack sichern Ger t sinngem in umgekehrter Reihenfolge wieder zusammenbauen Testlauf durchf hren dabei die Drehrichtung berpr fen siehe Richtungspfeil 5 3 2 Motor Dampfungselemente wechseln 316 Die Gummipuffer 316 sind alle 3 Jahre zu erneuern dabei sind die doppel seitigen Schleifpapierscheiben 315 ebenfalls zu wechseln Die Gummipuffer durfen nur Satzweise erneuert werden Antriebsmotor losschrauben siehe 5 3 1
27. d outstanding run characteristics Quality Products Lifetime Care It is easily removed for cleaning in the laboratory washing machine An extensive range of adapters permits centrifugation of all standard 5 7 10 and 15 ml tubes including the popular Monovette Vacu tainer and VenoJect blood collection tubes Safety Samples processed in today s laboratories often harbor unknown risks The Labofuge 200 complies with international safety standards and is equipped with a lid lock lid interlock and steel armoured guard ring Heraeus Benefits m Easy to Use E Able to run wide range of most popular medical tubes m Maintenance free m Safe lt Labofuge 200 Functions The microprocessor controlled Labofuge 200 is equipped with bright digital displays and touch pad keys for quick and easy setting of speed and run time The values last used are stored To repeat a run simply press the start key It is also designed with a user friendly self diagnosis system which indicates faults directly on the display esKendtro Laboratory Products TECHNICAL DATA Labofuge 200 230 V version 110 120 V version Description Microprocessor controlled table top centrifuge Maximum speed rpm 5300 5000 Minimum speed rpm 1600 1600 Maximum RCF x g 3030 2600 Minimum RCF x g 270 270 Maximum capacity ml 12x 15 glass 12 x 15 glass vibration insulation properties 240 x 284 x 375 9 5 x
28. e D9 Als IO oo Le 2 d T R28 es R5 PRIM x Bestuckungsplan Hauptplatte 178 120V Component Plan Main Board 178 120V 4 9 R17 D efKendro Li C10 LJ QA ur E d Z XA Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN et 1 ee CARR BREAK DOWN DRAWINGS esKenc ro Leistungsteil Bedien Anzeigenteil Power part Key and Indication part Verbindungskabel Connection cable 4 Pol Ausgabe Edition 02 Schaltbild Hauptplatte 178 120V Uebersicht Wiring Diagram Main Board 178 120V Overview 15 01 02 AH 4 10 Labofuge 200 SORVALL Heraeus CARR Deckelspulen EXPLOSIONSZEICHNUNGEN k S BREAK DOWN DRAWINGS efKendro D2 snes 9 vee NZ gt R7 Rg 4K7 470R SD SMD GND v2 1N4007 VCC ae d R3 68k 2W v14 ZMM15 N SMD H SMD V17 v13 BYT13 1000 EE Er D f Ro 47k ZN SMD MID Du SFH617G 3 R19 i 470R SMD GND v19 VI 1N4007 P STW15NB50 zn gt vee i R20 i 2k2 N D6 SMD SFH617G 3 V22 N IRG4BC30K ES N S Verbindungskabel lt P Connecting cable T XG D6 V20 BYT13 1000 SFH617G 3 R21 1 i 470R SMD GND GND k DECKELSCHALTER g i ons gt Lid switches SFH617G 3 GND H7 XB1 Nia tl c30 10u 50V R29 4k7 SMD GND R6 330R SMD Lid solenoid NJ v23 XD Y 4 R17 6 4 ez N ORG m Alle nicht bezeichneten Dioden LL4148 a
29. e bolts 214 remove them together with bushings 212 spring washers 213 and rubber O rings 215 and take off the lid e Reassemble the lid analogously in reverse order don t tighten the bolts too much to avoid a squeezing off of the O rings 5 1 3 Dismantling the Casing 205 Open the lid and pull out the mains plug Unscrew the rotor and remove it from the motor shaft Dismantle front panel and lid see 5 1 1 and 5 1 2 Remove both Phillips screws 204 from bottom plate in front and lateral from armored chamber e Disconnect the mains cable from terminal XA on main board and pull of the grounding plug e Pick up the front panel turn it to 90 and place it in front of armored chamber e Press the casing upwards and remove it from the bottom plate passing the front panel in vertical position e Reassemble the instrument analogously in reverse order Labofuge 200 SORVALL Heraeus CARR 5 2 Austausch elektrischer Komponenten 5 2 1 Sicherungen auf der Hauptplatte 113 ersetzen e Frontblende abnehmen siehe 5 1 1 e Die Feinsicherungen berpr fen und gegebenenfalls gegen gleichwertige unbesch digte austauschen e Testlauf durchf hren und versuchen die Uberlastungsursache zu ermitteln e Ger t sinngem in umgekehrter Reihenfolge wieder montieren 5 2 2 NV RAM 112 auf der Hauptplatte e Frontblende abnehmen siehe 5 1 1 e ACHTUNG CMOS Bauteile Entladen Sie Ihren K rper bevor sie das NV RAM ber hren Position d
30. eil Leistungselektronik Absicherung erfolgt zweipolig ber F1 und F2 6 3 AT e Tasten und Anzeigenplatte Programmierung MEGACONTROL einfach Teil der Hauptplatte e Einphasen Induktionsmotor mit Kondensator und integriertem bertemperatur schalter 125 C e Zweifache Deckelverriegelung mechanische Zuhaltung magnetische Entriegelung mit integriertem Mikroschalter eingebaut unter dem Geh use vorne rechts und links und innen an der Kesselwand befestigt und 3 2 Funktionen der Hauptplatte Die Hauptplatte 28 ist komplett hinter der Frontblende montiert Die Bauteile auf der Hauptplatte sind in folgende Funktionsgruppen aufgeteilt siehe Stromlaufplan 4 2 e Sicherungen der Hauptplatte 2 x 6 3 AT e Funkentstorung gem EN 55011 e Netzteil f r Versorgung des Prozessorteiles potentialgetrennt e Triacansteuerung f r Deckelmagneten DC Versorgung ber Diodenbrucke Diodenbr cke f r die Zwischenkreisspannung zur Speisung des Frequenz generators und des Bremskreises e Mikroprozessorteil mit Controller CPU e Austauschbares NV RAM mit zentrifugenspezifischen Daten und der Leistungselektronik 3 2 1 Netzteil Das Netzteil besteht aus Trafo Gleichrichter und Spannungsregler und liefert U1 5V fur die Versorgung von Microprozessor Tasten und Anzeigen elemente Bezugspotential Schutzleiter GND 3 2 2 Zwischenkreisspannung mit Bremszweig und Frequenzgenerator Der Zwischenkreis dient als Energiepuffer zwischen der p
31. endro 2 4 Cleaning of Instrument Parts ATTENTION WARNING The electrical and electronic components must not be cleaned with moist detergents For Cleaning the centrifuge housing or its accessories see Operating Instructions section 1 maintenance and care e Electronic components Clean dusty components carefully with a dry and soft brush and remove loose dust with a vacuum cleaner e Vent holes Remove dirt from vent holes of front panel or bottom plate using a brush and vacuum cleaner Labofuge 200 SORVALL Heraeus d CARR SERVICE esKendro 2 5 Endprufung 2 5 Electrical Safety Check ACHTUNG ATTENTION Eine Endprufung mu nach jeder Wartung und oder Reparatur durchgef hrt werden e Schutzleiterwiderstand pr fen Zwischen Netzstecker Schutzleiter und den Schutzleitern des Motors des Elektronik Chassis und des Geh usebodens darf der Me wert nicht ber 200 mQ liegen e Isolationswiderstand pr fen Pr fen Sie ebenfalls den Isolationswiderstand zwischen den Netzsteckerpolen und dem Schutzleiter er mu gr er als 2 MQ sein e Korperstrom nach EN 61010 messen Der K rperstrom darf im Fehlerfall unterbrochener Schutzleiter nicht gr er sein als 3 5 mA In Anlehnung an EN61010 IEC1010 und UL3101 l t sich mit nachfolgender MeBschaltung ein solcher Fehlerfall nachbilden 15009 5 Ausgabe Edition 03 2 8 18 04 02 AH K rperstrom accessible current U 1750mV bha 3 5mA A fina
32. er Rechteckspannung variiert Die eingestellte Drehzahl wird innerhalb des g ltigen Netz Spannungsbereiches mit einer Genauigkeit von 5 erreicht 3 2 3 Mikroprozessor Teil Die Schaltung enth lt folgende Teile Mikrocontroller CPU 87C51 und einen Datenspeicher NV RAM 9346 Das ROM mit dem Steuerprogramm ist in der CPU integriert Die wichtigsten Betriebsparameter z B die maximale Drehzahl oder die zuletzt eingegebenen Daten sind in dem NV RAM gespeichert 3 2 4 Tasten und Anzeigenplatte Die Tasten und Anzeigenplatte ist Bestandteil der Hauptplatte Die Verbindung zur Hauptplatte erfolgt uber ein 14 poliges Flachkabel Die 7 Segmentanzeigen Leuchtdioden und die Bedientasten werden vom Mikrocontroller im Multiplexverfahren gesteuert Als Bedieneroberfl che dient MEGACONTROL einfach siehe Betriebsanleitung Ausgabe Edition 02 16 01 02 AH FUNKTIONSBESCHREIBUNG FUNCTIONAL DESCRIPTION esKendro Brake Path To braking the centrifugal drive the induction motor is supplied with DC pulses from the intermediate circuit affects as frequency zero The pulse frequency is variable in dependance of the braking time equal to speed as a result of which the noise level is changed Frequency Converter The frequency converter provides the drive motor with squarewaved voltage blocks having an amplitude of the half of the DC intermediate circuit voltage These blocks are variable controlled in frequency and pulse width modulation
33. er Rotor hat 10000 Gummipuffer ersetzen the display une Rotor has reached Replace rotor NV Ram and abgelaufen Arbeitszyklen erreicht Service Kit ww GE expired 10000 cycles motor supports Service Kit Ausgabe Edition 03 2 5 Labofuge 200 18 04 02 AH Dar eK eraeus d SERVICE eeKendro 2 3 MeBpunkte 2 3 Test Points Test Points Me punkte MeBwert Alle angegebenen Strom Spannungswerte sind 230V AC All given voltage and current values refer either ai e auf 230V Netzspannung 10 bezogen Ree AP AoW AV to 230V 10 or 120V 10 Deckelschalter Lid micro switch 320V DC Voltage drop by open lid at 230V units SteckerXB 920V DU Spannungsabfall bei offenem Deckel Plug XB 160V DC Voltage drop by open lid at 120V units Rotor 3760 unbeladen jeweils gemessen nach Rotor 3760 not loaded in each case measured ca Erreichen der Solldrehzahl approx after reaching the selected speed 58V AC 1600min Terminal XC 58V AC 1600rpm Klemme XC 1 105V AC 4000min 105V AC 4000rpm Motorspannung 120V AC 5300min Motor voltage 420V AC 5300rpm 80V AC zu Beginn der Bremsphase 80V AC atthe beginning of the braking phase am Ende der Bremsphase 75V AL atthe end of the braking phase Rotor 3760 unbeladen jeweils gemessen nach Rotor 3760 not loaded in each case measured Erreichen der Solldrehzahl mit Weicheisen after reaching the selected speed with a soft iron 1 5 od Effektivwert Me instrument approx or digital effective
34. es 8 poligen NV RAMs merken und vorsichtig aus der Fassung ziehen e Neues NV RAM in richtiger Position wieder in den Sockel eindr cken e Frontblende wieder in umgekehrter Reihenfolge montieren Ger t wieder in Betrieb nehmen und Testlauf durchf hren 5 2 3 Hauptplatte 110 ACHTUNG Die Anzeigenplatine ist Bestandteil der Hauptplatte und kann nicht einzeln bestellt werden e Frontblende abnehmen siehe 5 1 1 e Steckverbindungen fur Deckelschalter XB Erdungsstecker PE und Klemm verbindungen fur Deckelmagnete XD Motor XC und Netzanschlu XA losen e Verschraubungen der Haupt und Anzeigenplatte Ejot 111 und 122 mit Fiberscheiben 121 entfernen und beide Platten entnehmen e Entladen Sie Ihren K rper bevor Sie CMOS Bauteile ber hren Entnehmen Sie ein neues NV RAM 112 der Transportschachtel oder wiederverwenden Sie das alte aber einwandfreie Bauteil und stecken Sie es in den Sockel der Hauptplatte entfernen Sie das auf der neuen Platte eingesteckte aber unprogrammierte NV RAM e Neue Haupt und Anzeigenplatte korrekt plazieren und mit allen Schrauben und Fiberscheiben montieren e Vor dem Wiedereinbau alle Tasten auf einwandfreie Druckfunktion berpr fen und ggf die Plattenbefestigung korrigieren e Abgeklemmte Kabel beim Wiedereinbau nicht vertauschen e Ger t sinngem in umgekehrter Reihenfolge wieder zusammenbauen und Testlauf mit Drehrichtungskontrolle siehe Pfeil neben Kammerwand durchf hren Ausgabe Edition 0
35. gigkeit berpr fen Check for easy rotor Displays a nh Rotor ist blockiert blockierende Gegenstande Displays Rotor didn t Rotor is jammed movement remove any leuchten ener entfernen are turn Jamming objects drehen aber Motor sitzt fest hl Motor is jammed Replace motor Antrieb ut drive arte fehleratte Leunen Saanaa L ibmaen doesnt Connections ner cheek ternal and en nicht Kontakte Se H start drive and main board a y Motor l uft Wicklungswiderst nde pr fen Motor didn t i e Check resistance of motor nicht an MOISEBEIEN und defekten Motor ersetzen start Elec anya windings replace faulty parts Kondensator defekt Kondensator ersetzen Faulty condenser Hauptplatte komplett Remove main board Hauptplatte defekt Faulty main board _ Remove main board Antrieb Verschlei der Motord mpfungselemente Wear out of motor macht Antriebsd mpfung is Een a IS Gerau BE Change motor completely nn Klemmen Zuleitung Spannungen an den Motor good Defective terminal Check voltage on motor ter N Elektrisch oder Motorwicklung klemmen messen defekte separation Electrical Conmecton faulty lead minal and winding resistances ergebnis A EE result or motor winding see test points on boards Defective driving aan Ausgabe Edition 03 2 3 Labofuge 200 18 04 02 AH Replace main board Let motor cool down then check temperature switch and leads with Ohmmeter SORVALL See esKendro Fehlersuchplan Trouble Shooting Anzeige m
36. iagram Main Board 178 120V Key and Indication part 15 01 02 AH 4 12 Labofuge 200 SORVALL Heraeus Die im folgenden Kapitel angef hrten Indexnummern in den sind in den Explosionszeichnungen und Ersatzteillisten wiederzufinden 5 1 _Geh useteile demontieren 5 1 1 Frontblende demontieren 102 e Netzstecker ziehen und Ger t von der Tischkante um Frontblendenbreite nach hinten stellen e Beide Kreuzschlitzschrauben Ejot 101 am unteren Rand der Frontblende herausdrehen e unteren Rand der Frontblende leicht nach vorn ziehen max um 15 damit die Kunststoffhaken am oberen Rand nicht abbrechen e Frontblende nach oben aus der Geh useverbindung schieben und vor dem Geh use ablegen e Frontblende sinngem in umgekehrter Reihenfolge montieren am unteren Rand fest andr cken und festschrauben Ejot Schrauben dabei nicht allzu fest anziehen da sonst das Kunststoffgewinde im Geh use leicht berdreht werden kann 5 1 2 Deckel 210 e Deckel ffnen und Netzstecker ziehen e Beide Deckelbolzen Verschraubungen 214 l sen und komplett mit Buchsen 212 Federscheiben 213 und O Ringe 215 entfernen und den Deckel abnehmen e Deckel sinngem in umgekehrter Reihenfolge montieren Deckelbolzen 214 nicht allzu fest anziehen um ein Abquetschen der O Ringe zu vermeiden 5 1 3 Geh use demontieren 205 Deckel ffnen Netzstecker ziehen Rotor l sen und herausnehmen Frontblende und Deckel abschrauben siehe 5 1 1 und 5 1 2
37. ion Ausgabe Edition 02 Blockschaltbild Block Diagram EE 15 01 02 AH 4 1 Labofuge 200 SORVALL Heraeus CARR Hauptplatte Main Board XPE Netz Mains F1 F2 6 3AT bei 230V 6 25 bei 120V 6 3AT at 230V 6 3AT at 120V L PE PE Chassis Motor Ausgabe Edition 02 15 01 02 AH EXPLOSIONSZEICHNUNGEN BREAK DOWN DRAWINGS Trafo Gleichrichtung u Stabilisierung Transformer Rectifiers and Regulators filter Noise Filter XC 1 XC 2 E Y1 FA Fa Deckelspulen Lid solenoid Stromlaufplan Schematic Diagram 4 2 5V VCC NTC t Funk wm entst r Gleichspannungs zwischenkreis DC intermediate circuit efKendro Oo Deckelschalter Bremswiderstand Lid Switch Brake Resistor Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN DL en Sr E s kend Hauptplatte Teil 2 H1 TREE E F G DP Main Board Part 2 XG XG RESET lt uP Teil uP Part Stromme widerst Current Control Res gt C R25 26 ly 14 4 CPU NV RAM Tasten und Bedienteil i K nd indication Ci P ey and indication part Q O Galvanische Trennung gt F C Physical Separation eg C 6uF bei 230V C 12uF bei 120V C 6uF at 230V C 12uF bei 120V Motor und Laufkondensator Motor and run capacitor Ausgabe Edition 02 Stromlaufplan Schematic Diagram 15 01 02 AH 4 3 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN SL ae
38. ions the rotor and or accessory parts must not be used any longer if there are visible traces of mechanical damage Labofuge 200 SORVALL Heraeus CARR SERVICE Wartungsplan 2 1 1 6 Rotor Befestigung und Motor Welle e Rotor Befestigungsmutter auf einwandfreien Zustand hin berpr fen und im Zweifelsfall ersetzen e Hochleistungsrotoren aus Kunststoff besitzen eine begrenzte Lebensdauer Aus Sicherheitsgr nden sind sie nach 5 Jahren Gebrauchsdauer oder 10000 Arbeitszyklen auszutauschen Das Verfallsdatum expiry date ist an der Datumsuhr in der Rotorunterschale zu erkennen Die 2stellige Nummer im Zentrum steht f r die Jahreszahl und der Pfeil weist auf den Verfallsmonat Durch gleichzeitiges Bet tigen der beiden set Tasten kann bei geschlossenem Deckel berpr ft werden wieviel Arbeitszyklen f r den vorhandenen Rotor noch m glich sind Die Anzeige erfolgt im Drehzahlfeld e Motor Welle auf evtl Besch digungen untersuchen die Zentrifuge darf nicht weiter benutzt werden wenn die Antriebswelle besch digt ist z B verbogen Gewinde abgenutzt waagerechte Riefen 2 1 1 7 Temperaturentwicklung e L ftungsschlitze hinten unter dem Deckel und unter der Bodenplatte auf Durch lassigkeit berpr fen bei nicht ausreichendem Luftdurchsatz steigt die Temperatur von Rotor Motor und Elektronik unzul ssig hoch an 2 1 2 Routinem ige Wartung nach Zerlegung der Zentrifuge 2 1 2 1 Motor D mpfungselemente e berpr fung der
39. l electrical safety check must be performed after each maintenance and or repair e Resistance check of protective conductor The measuring value of the resistance between the mains plug s grounding pin and the grounding conductors of the motor electronic chassis and the casing must not exceed 200 mQ e Insulation resistance Check Check also the insulation resistance between the poles of the mains plug and the grounding conductor the resistance value must be more than 2 MQ e Accessible current measured to EN 61 010 The accessible current must not exceed 3 5 mAmps in single fault condition interrupted protection earth wire In accordance with the EN61010 IEC1010 and UL3101 such a fault condition can be reproduced by the following measuring circuit Steckergeh use plug in casing Spezifaktionen fur MeBgerat TRMS DC 5kHz oder mehr Eingangswiderstand gt 1MQ Toleranz 5 oder besser Crest Faktor 5 oder besser 0 022uF 5 Specifaction for the meter TRMS DC 5kHz or more Input resistance gt 1MQ Tolerance 5 or better Crest Factor 5 or better mA U mV 500 Labofuge 200 SORVALL Heraeus CARR 3 1 Allgemeine Beschreibung der Baugruppen Die Labofuge 200 ist eine mikroprozessorgesteuerte Laborzentrifuge mit Induk tionsmotor und integrierter Luftk hlung Das Ger t enth lt die folgenden Baugruppen siehe Blockschaltbild 4 1 e Hauptplatte 28 f r 230V Netzversorgung mit Mikroprozessort
40. le Shooting 28 5 23 Test Points 2 2 4 Cleaning of Instrument Parts 2 2 5 Electrical Safety Check oZ 128 EEE DE a S FUNCTIONAL DESCRIPTION E EE 3 1 Block Functions Lt D 32 FunctionsofMainBoard 8D en KE pe 4 DIAGRAMS abo 4 1 Block Diagram a 42 Wiring Diagrams 4 4 3 Wiring Connection Diagrams _ __ _ DT 44 4 4 Main Board 28 230V Component Dien D AS 4 5 Main Board 28 230V Wiring Diagram 468 4 6 Main Board 178 120V Component Dan D 49 4 7 _ Main Board 178 120V Wiring Diagram D 410 11 EEE ER En ee 5 DISASSEMBLY OF INSTRUMENT PARTS Labo2005 5 1 Housing CasingParts CK L Electrical Components SS 5 3 Drive Components Cd OT 5 4 Mechanical Components Cd CO 5 5 Service Kit LIT 188 EZ EEE Kl 6 SPARE PART FIGURES AND LISTS II 62 Spare Part Lists TT EZ EEE BE a Preventive maintenance checklist KE 8 TECHNICAL BULLETINS J Labofuge 200 Heraeus KOMPAKTE KLEINZENTRIFUGE LABOFUGE 200 Einfach zu bedienen Die Heraeus Labofuge 200 besticht durch funktionelles und elegantes ergonomisches Design Der g nstige Anschaffungspreis ist ein zus tzliches Plus Sie l sst sich ideal in Arztpraxen und kleineren Laboratorien sowie als Stand by Ger t in Gro labors einsetzen Vorteile m einfachste Bedienbarkeit E preisg nstiges Komplettsystem E vielf ltiges Zubeh r auch f r medizinische Anwendungen m modernste Technik f r
41. ler No Misuse can lead to main board destruction The specific variants can be identified as follows a Mains NV RAM Controller Additional identifying No of NT RE unit connection signification signification information and further notes 220V 50Hz minimum speed setting 3000 220V 50Hz min 1 E 02 message 220V 50Hz main board 150043 220V 60Hz components on both sides minimum speed setting 1600 min 1 no E 02 message 1052 V01 main board 150043 components on both sides or main board 150061 SMD cycle counter is set to 10500 the first time 3630 220V 50Hz 1052 vo3 0474 Main board 28 150103 SMD main board 150061 older version V02 is cancelled main board 14 150076 3631 120V 50Hz 1066 V02 0474 or main board 178 150178 Die einzelnen Varianten lassen sich wie folgt unterscheiden Ger te Netz Kennzeichn ZE Bestell Anschlu des NV Controller Nr RAMs 220V 50Hz 220V 50Hz 220V 50Hz 220V 60Hz minimale Drehzahl Einstellung 1600 min 1 E 02 entf llt zo 1052 V01 Hauptplatte 150043 beidseitig best ckt oder Hauptplatte zus tzliche Erkennungsmerkmale und weitere Hinweise minimale Drehzahl Einstellung 3000 min 1 E 02 Hauptplatte 150043 beidseitig Labo 8 or Labo ALT Labo 8 oder Labo ALT eae 220V 50Hz 220V 50Hz Zyklenzahler ist erstmals auf 10500 gesetzt 220V 50Hz 1052 V03 0474 Hauptplatte 28 150103 SMD Hauptplatte 150061 alte Version V02 entf llt Ausgabe Edi
42. measuring instrument Motorstrom Im eeh d Motor current Im eh on 5300min 0 8A 5300rpm kurzzeitig bei max Beschleunigung 3 3A maximum during acceleration kurzzeitig bei max Bremsung 2 0A maximum during braking phase Ger t ausschalten und Motor abklemmen switch OFF unit pull off motor plug Motorwicklungs Hauptwicklung sw gn Motor windings mains winding black green widerstand 20 C Hilfswicklung sw ge resistance 20 C auxiliary winding black yellow Isolationswert jeder Leiter gegen Stator Geh use gemessen insulation value resistance inter each phase and motor casing Deckelmagnet Gerat ausschalten l switch OFF unit Klemme XD E Wicklungstemperatur 20 C a gt enog 1052 resistance at 20 C 68 F at 230V units terminal XD 290 resistance at 20 C 68 F at 120V units Ausgabe Edition 03 2 6 Labofuge 200 18 04 02 AH SORVALL Heraeus CARR 2 4 Reinigung ACHTUNG WARNUNG Keine elektrischen oder elektronischen Bauteile mit feuchten Reinigungs mitteln s ubern Zur Reinigung und Pflege der Gehauseteile und des Zubeh rs siehe Gebrauchsanweisung in Sektion 1 Abschnitt Wartung und Pflege e Elektronik Baugruppen Verstaubte Platinen vorsichtig mit einem trockenen und weichen Pinsel reinigen und losen Staub absaugen e Luftschlitze Verschmutzte Luftschlitze in der Frontblende oder in der Bodenplatte mit einer B rste reinigen und losen Schmutz absaugen Ausgabe Edition 03 18 04 02 AH SERVICE esK
43. nd Indication part Verbindungskabel Connection cable 4 Pol Ausgabe Edition 02 Schaltbild Hauptplatte 28 230V Uebersicht Wiring Diagram Main Board 28 230V Overview 15 01 02 AH 4 6 Labofuge 200 SORVALL Heraeus EXPLOSIONSZEICHNUNGEN S CARR BREAK DOWN DRAWINGS e8Kendro D2 SFH617G 3 emm vee VW R7 R8 i 4k7 470R 3 SMD SMD 5 GND V2 1N4007 VCC O R18 2k2 SMD V17 nn ine sok SFH617G 3 R19 i 470R SMD GND v19 V1 1N4007 STW15NB50 ver C i R20 i 2k2 De SMD BFH617G 3 v20 BYT13 1000 l d Verbindungskabel lt TD Connecting cable XG o D 1 14 SFH617G 3 R21 j 470R 2 13 vec SMD GND Hz GND k DECKELSCHALTER D A 1 GND GND L Lid switches SFH617G 3 7 XB1 lt VW C30 10u R4 v12 a 50V 470R P6KE400A ow BE eee eee R12 10k R29 v18 d SMD IRF840 LD vee ef Kl Ee R16 Ka 10k Ds SMD SFH611 3 GND GND R6 330R SMD Deckelspulen a Lid solenoid NI v23 XD E 6 d ez N Alle nicht bezeichneten Dioden LL4148 ASZEM el All not marked Diodes LL4148 D 4 2 N nn N F1 L1 GND Netz SI 6 3AT 5 6mH gs NN eet ett eee Mains Se XA A C6 L1 om F2 470k SI 6 3AT Kc 2 4 N IS PE ka Ti O T230V 9V an is VR3109 T40 E BLOCK 2n2 2n2 C7 PE1 Y 100n O 1 GND GND SMD 2 GND GND Ausgabe Edition 02 Schaltbild Hauptplatte 28 230V Leistungsteil Wiring Diagram Main Board 28 230V Power part 15 01 0
44. ogliche Error Possible Error nn Error Cause Corrective Procedure Verhalten Fehlerquellen Indication Source Antrieb Kein Drive Fehler auf der No brake l Remove main board g i SE Hauptplatte Haupiplatte austauschen on Faulty main board completely and replace it fehlende Netzspan Abhilfe siehe oben Remedy see above manual Deckelspule nung Not ffnung nur im Stillstand Lid coil is not voltage opening only at standstill Deckel l t erh lt keine PTC Widerstand hat Taste nach 1 2 Minuten or not PTC resistor has After a waiting time of 1 2 in oder zu ausgel st erneut dr cken WEE ee released minutes press key again Stillstand En o Ansteuer od Triac Hauptplatte komplett be opened Faulty driving or triac Replace the complete main nicht mit schaltkreis defekt austauschen by key circuit board Tasten Deckelspule Spule defekt Deckelschlo austauschen pressure at Faulty lid coil Faulty winding of coil Replace complete lid lock druck Deckel ins Schlo dr cken standstill ve SC Push lid into lock and press ffnen Deckel ist Deckellasche klemmt Taste erneut bet tiaen Lid is not Lid bolt is jamming Kerzen nicht richtig correctly ee eingerastet Deckel ist ern Deckel seitlich ausrichten locked Lid e OP ormen Si Readjust the lid centrically oder falsch justiert disadjusted Deckel sofort schlie en Netz Lid was Forbidden intervention Close lid immediately turn AUS EIN Bremsphase br opened Emergency opening power off on wait for abwarten
45. ransformer e Triac control circuit for lid solenoid DC supply via bridge rectifier Bridge rectifier for DC intermediate circuit supplying brake path and frequency converter e Microprocessor part with CPU e Exchangeable NV RAM containing specific data of the unit and power 3 2 1 Power Pack The power pack transformer bridge rectifier and voltage regulator generates U1 DV supplies central processor key and indication board reference potential protective conductor GND 3 2 2 Intermediate Circuit with Brake Path and Frequency Converter The DC intermediate circuit serves as an energy store between the AC power input and the transmitted motor performance The intermediate circuit consists of a bridge rectifier 4 diodes and two serial connected reservoir capacitors The intermediate circuit is over voltage protected Labofuge 200 SORVALL Heraeus CARR Bremszweig Zum Bremsen des Zentrifugenantriebs wird der Induktionsmotor mit Gleichspannungspulsen Wirkung wie Frequenz Null aus dem Zwischenkreis beaufschlagt Die Pulsfolgefrequenz wird abh ngig von der Bremszeit entsprechend der Drehzahl ver ndert wodurch sich ein ver nderter Ger uschpegel ergibt Frequenzgenerator Der Frequenzgenerator liefert f r den Antriebsmotor eine Rechteckspannung mit ver nderlicher Frequenz und einer Amplitude in H he der halben Zwischenkreis spannung W hrend der zeitlich gesteuerten Beschleunigsphase wird auch die Pulsbreite d
46. rifugierens Labofuge 200 Die Labofuge 200 entspricht internatio nalen Sicherheitsvorschriften und ist mit Deckelverriegelung und zuhaltung sowie einem stahlgepanzerten Schutzmantel ausger stet Funktionen Die mikroprozessorgesteuerte Labofuge 200 verf gt ber helle Leucht anzeigen und Sensortasten die das rasche Einstellen von Geschwindigkeit und Laufzeit erlauben Da die zuletzt eingegebenen Werte gespeichert bleiben k nnen Wiederholungsl ufe einfach mit der Starttaste abgerufen werden Eine servicefreundliche Selbstdiagnose ist ebenfalls Bestandteil des Ger tes und zeigt eine eventuelle Fehlfunktion direkt im Display an e2Kendro Laboratory Products TECHNISCHE DATEN Labofuge 200 Beschreibung Mikroprozessorgesteuerte Tischzentrifuge Maximale Drehzahl min 5300 Minimale Drehzahl min 1600 Maximale RZB x g 3030 Minimale RZB x g 270 Maximale Kapazit t ml 12 X 18 Steuerung Zeit und Drehzahl mikroprozessorgesteuert Antrieb b rstenloser Induktionsmotor mikroprozessorgesteuert Laufzeit 1 99 min und Dauerbetrieb Programmspeicher zuletzt eingegebene Werte werden unbegrenzt gespeichert Sicherheit Deckelverriegelung und zuhaltung Schutzmantel Aufbau schall und vibrationsd mpfendes Kunststoffgehause Stahlschutzmantel Abmessungen HxBxT 240 x 284 x 375 mm Gewicht inkl Rotor kg ca 10 7 Leistungsaufnahme W 65 Sensortaste zum Einstellen der BESTELL NUMMERN Lauf
47. sch digt O Rotorkammer sauber O Tasterfolie sauber unbesch digt O Umgebungsbedingung sauber u stabiler Tisch Funktionspr fung O Netzspannung V AC O Funktion Siebensegmentanzeigen O Funktion Taster O Funktion Deckelverriegelung O Deckel ffnung bei Stillstand lt 50rpm Mechanisch O Motorlager O Gummipuffer Motor O Gummiflansch Motor O Deckeldichtung Revised 16 01 02 Parameterpr fung o Beschleunigungszeit o Maximaldrehzahl o Bremszeit o Zeit 10 min Vorwahl VDE Sicherheitstest o Ersatzableitstrom lt 3500uA Labofuge 200 Medifuge 200 Type S N sec min 1 sec tats chlich min sec o Isolationswiderstand gt 10 Megaohm o Schutzleiterwiderstand lt 0 2 Ohm 1 of 2 Kendro Service Information Kommentar Unterschrift Datum Revised 16 01 02 2 of 2 Kendro service Information Heraeus Centrifuges Laboruge 200 PREVENTIVE MAINTENANCE CHECKLIST type S N Rotor Inspection Performance Checks O Visual inspection o Acceleration time seconds O Rotor locking screw o Instrument top speed rom O Expiry date o Deceleration time seconds EENEG o Time 10 minute set actual min sec O Cycle counter checkup Preliminary Checks Safety test o Cabinet o Accessible leakage current lt 3500uA clean undamaged o Insulation resistance gt 10 Megaohm o Rotor chamber o Earth Conductor Resistance lt 0 2 Ohm clean O Key foil clean undamaged O Installation environment level
48. seconds and re start zahlfeld Stillstand speed braking force displa Check leads and micro switch Ausgabe Edition 03 2 4 Labofuge 200 18 04 02 AH SORVALL See esKendro Fehlersuchplan Trouble Shooting Anzeige mogitens ao Error Cause be or Corrective Procedure Verhalten Fehlerquellen Indication Source E 2 E 2 I I ae Wartungs Rotor NV Ram und message Maintenance Anzeige im z hler Rotor hat 10000 Gummipuffer ersetzen appears in counter Sc abgelaufen REESEN Service Kit speed expired field Nee 3 E s B re Fehler auf der Defekte Hauptplatte komplett a remsstrom appears in Drehzahl Gite Hauptplatte ersetzen speed feld field SE NV RAM ist nicht NV RAM und Sockel pr fen Be NV RAM is not Check NV RAM and socket initialisiert oder falsch korrektes NV RAM einsetzen se ele RAM initialized or false insert the correct NV RAM E 12 ist falsch E 12 Le i Fehler bei message a der appears in Disturbed feld Daten ber Fehler auf der Defekte Hauptplatte komplett speed data transfer Faulty main board Remove main board nahme aus Hauptplatte ersetzen field from NV completely and replace it dem NV RAM RAM Rotor has reached Replace rotor NV Ram and 10000 cycles motor supports Service Kit Anzeige im No brake Remove main board current PALY AN DOANG completely and replace it Alle Wartungs Rotor NV Ram und All dots in Maintenance Dezimal punkte leuchten Z hl
49. stellt werden Geh use demontieren siehe 5 1 3 Leitungen zu den Deckelmagneten von Anschlu XD abklemmen und Steckverbindung XB f r die Mikroschalter abziehen Die beiden oberen Befestigungsschrauben 305 an beiden Deckelschl ssern von innen aus dem Panzerkessel herausschrauben und die unteren beiden Ejot Schrauben 304 von au en abschrauben Hebel der Mikroschalter herunterdr cken Mikroschalter durch die Kessel ffnung f hren und Schlo komplett mit Gummi Unterlegplatine nach oben entnehmen Neue Deckelschl sser sinngem in umgekehrter Reihenfolge wieder einbauen Dabei die Gewinde der oberen Befestigungsschrauben 305 mit Loctite 221 sichern Ger t sinngem in umgekehrter Reihenfolge wieder zusammenbauen Nach dem Einbau berpr fen ob der Deckel korrekt schlie t und selbstt tig ffnet eventuell die Gummidichtung 206 austauschen Ausgabe Edition 02 16 01 02 AH Both lid lock assemblies inclusive micro switches are combined to one spare part and cannot be ordered separately Dismantle the casing see 5 1 3 Disconnect the leads of the lid solenoids from terminal XD and pull out the plug XB for the micro switches Unscrew both upper screws 305 of the lid lock assemblies attachment from the inside of the armored chamber and the lower Ejot screws 304 from the outer side Push down the levers of micro switches guide the micro switches through the openings of the armored chamber and remove both lid lock
50. tion 02 5 5 Labofuge 200 16 01 02 AH R no EXPLOSIONSZEICHNUGEN CARR BREAK DOWN DRAWINGS e Kendro Ausgabe Edition 02 Gehauseteile Cabinet 15 01 02 AH 6 1 Labofuge 200 efKendro EXPLOSIONSZEICHNUGEN BREAK DOWN DRAWINGS SORVALL Heraeus CARR Se 0 N N q d sy IE N _7 Panzerung Antrieb Armouring Drive Ausgabe Edition 02 15 01 02 AH Labofuge 200 Ersatzteil Liste 75003630 01 von Fabriknr Index 00101 00102 00103 00105 00110 00111 00112 00113 00121 00122 00204 00205 00206 00207 00208 00210 00211 00212 00213 00214 00215 00221 00222 00223 00224 00225 00226 00227 00232 00233 00234 00235 00236 00237 00300 00304 00305 00307 00308 00310 00311 00313 00314 00315 Donnerstag 17 Januar 2002 Artikelnr 20460133 20022598 20022604 20290521 20150103 20460137 70901052 20230145 20250031 20460132 20460088 20020726 20020717 20220561 20290473 70020819 20050543 2035021 1 20480250 20037565 20290419 70022871 70022870 20480251 20430216 20022867 20480224 20460092 20480157 20049932 20460112 20480108 20220510 20420076 20003620 20460138 20440295 20022873 20220416 20210275 20020738 20420070 20480251 10104080 Kendro Laboratory Products Werk Osterode LABOFUGE 200 230V 50 60HZ bis Fabriknr Text EJOT PT KB 030X014 SCHR LINS KR FRONTBLENDE TASTERFOLIE LABO 200 HS MOOSGUMMI RUND 2 0 MM EP
51. ulsierenden Eingangs leistung des Netzes und der abgegebenen Motorleistung Er ist als Gleich spannungszwischenkreis mit Gleichrichter Diodenbrucke und Glattungskonden satoren aufgebaut Der Zwischenkreis ist vor berspannungen gesch tzt Ausgabe Edition 02 16 01 02 AH FUNKTIONSBESCHREIBUNG FUNCTIONAL DESCRIPTION esKendro 3 1 Block Functions The Labofuge 200 is a microprocessor controlled laboratory tabletop centrifuge with induction drive motor and integrated air cooling system The unit incorporates following boards and components see block diagram 4 1 e Main board 28 for 230 V mains supply or main board 178 for 120 V mains supply with microprocessor part and power electronics e Key and indication board programming MEGACONTROL simple part of the main board e 1 phase induction motor with phase shift capacitor and integrated thermal over temperature switch C O 125 C e Double lid lock assembly with solenoid and integrated micro switch mechanical bolt keeper magnetically dislocking attached in front on both sides of the vessel 3 2 Main Board Functions The main board 28 178 is mounted completely behind the front panel The components on main board are arranged in following groups see wiring diagram page 4 2 e Board fusing 2 x 6 25 6 3 Amps slow blow feature Noise filter in accordance with EN 55011 e Power pack for low voltage supply of microprocessor part electronics potential separated by t
52. und stoppen Der Deckel darf beim Dr cken der Deckel auf Taste solange nicht entriegelt werden bis die end Meldung im Drehzahlfeld erscheint im Fehlerfall ist die Hauptplatte auszutauschen 1 4 Reinigung von Rotor Kammer Motor Geh use e Deckel ffnen und Rotor ausbauen zum L sen Zentrale Fl gelmutter durch Linksdrehen von der Antriebswelle l sen e Zur Reinigung der Rotor Kammer ein trockenes und saugf higes Tuch verwenden Schmutz und Feuchtigkeitsr ckst nde m ssen entfernt werden e Auf Sauberkeit des Motor Geh uses um die Motorwelle herum ist zu achten das Eindringen von Fl ssigkeiten f hrt zur Besch digung des oberen Motor Lagers Fl ssigkeiten mit Spritze oder saugf higem Tuch entfernen 2 1 5 Rotor und Zubeh r Zustand und Dichtung e berpr fung des Zustandes von Rotor und Zubeh r Teilen insbesondere alle tragenden oder stark beanspruchten Teile Rotor und oder Zubeh r Teile d rfen nicht l nger benutzt werden falls dort sichtbare Spuren von Rissen erkennbar sind Ausgabe Edition 03 18 04 02 AH 2 1 1 1 Electrical Installation and Safety e Switch OFF the centrifuge and disconnect the unit from power check voltage supply and mains fusing 16 Amps slow blow characteristic e Check condition of plug and wall socket let replace defective parts e Check cord condition and fixing connection replace or refit it 2 1 1 2 Location and Mechanical Installation e Check
53. zeit Gerat Bestell Nr Labofuge 200 230 V 50 60 Hz 75003630 110 120 V 50 60 Hz 75003631 Zubeh r f r Labofuge 200 Winkelrotor HFP 5 15 75003760 Max Drehzahl min 5300 Max RZB x g 3030 Max Kapazit t ml 12x15 Max Radius cm 9 65 Mit der Start Taste k nnen Beschleunigungsdauer s 40 Wiederholungsabl ufe einfach Bremsdauer s 45 abgerufen werden Zubeh r f r Winkelrotor HFP 5 15 Gef Nennma e mm 117x100 116x100 16X85 12x 100 13x75 Nominales Gef volumen 15 dE 10 T 5 Anzahl der Gef e pro Rotor 12 12 12 12 12 Best Nr Gef 9080 9003 9001 Best Nr Adapter 3763 3762 3227 3227 1 ist im Lieferumfang der Zentrifuge enthalten 2 gemessen bei 230 V 3 Bei berl nge Gef zwischen 100 und 131 mm Reduzierung auf max 6 St ck 4 Bei Verwendung von Sarstedt Monovette Gef en L nge inkl Kappe 117 mm Reduzierung auf max 6 St ck 5 Borosilikat Glas 6 Polypropylen R hrchen Ihr Partner esKendro Laboratory Products Ihr Kontakt in Deutschland Berlin D sseldorf Gera Hamburg Hanau M nchen N rnberg Stuttgart Vertrieb Kendro Laboratory Products GmbH Tel 01805 536 376 Fax 01805 112 114 info kendro de Service Kendro Laboratory Products GmbH Tel 01805 112 110 Fax 01805 112 114 info kendro de Europa Naher Osten und Afrika Kendro Laboratory Products International Sales Hanau Tel 49 6181 35 3

Download Pdf Manuals

image

Related Search

Related Contents

Samsung K5 1GB Benutzerhandbuch  VGN-FZ190E/2 - Clearance Club  First Alert KV-T29SN81 CO410 User's Manual  LIBRETTO ISTRUZIONI INSTRUCTION BOOK NOTICE D  Sommaire - Commune de Saint  安全データシート - ジーエルサイエンス  MODEL: F20XE 取 扱 説 明 書  Prio API Quick Start Guide  Sheep Auto Drafter User Manual  PDF Infoblatt - Gravity Boots  