Samsung AR24JRSDBWKNMG User Manual

image

Contents

1. D o oo Doo 00 oo Batteries for Remote controller 2 a User s amp Installation Manual 1 L Remote Control Holder 1 M4 x 12 Tapped Screws 2 HHT18JR JQHH sum M4 x 16 Tapped Screws 2 HH24JR JQ sau Cap Screws 2 Q Accessories in the outdoor unit case Drain Plug 1 Rubber Leg 4 HHKJQAKHX ta IG English 37 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 37 2 17 2015 2 56 43 PM The flare nuts are attached to the end of each pipe of an evaporator or a service port Note Use the nuts when connecting the pipes The wire assembly cable is optional If it is not supplied use the standard cable The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below I Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air conditioner Insulated Assembly Pipe Insulated Assembly Pipe Insulated Assembly Pipe 63smmxsm 1 kx1sk O12 70mmx5m 1 B1588mmx4m 1 PET3 Foam Tube Vinyl Tapes 2 Drain Hose 06 35 mm x 4 m 1 KX24 X K1B KK KK Insulation 1 length 2 m 1 2 amp Q Putty 100 g 1 Pipe Clamps A 3 Pipe Clamps B 3 Cement Nails 6 32 Q Q 4 wire Assembly Cable 1 918 24 s Q M4
2. MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 30 D 2 17 2015 2 56 36 PM Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner e Check power status and then operate the air conditioner again does not work at all Plug in or switch on the circuit breaker and then operate the air conditioner again Ensure Isolator is switch on e Check if you have set the Off Timer Operate the air conditioner again by pressing the Power button The temperature e Check if you have selected Fan Fast mode In these modes desired adjustment is not working temperature is set to auto and you cannot adjust the temperature Cool Warm air does not come out of the air conditioner Check if the set temperature is higher during Cool mode lower during Heat mode arx Jo gt than the current temperature Press the Temp or button on the remote controller to change the set temperature Check if the Air filter is blocked by dirt If there is a lot of dust on the Air filter cooling heating ars performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away Check if the air conditioner is operating in Defrost mode When the ice formed in winter or the outdoor temperature is too low the air conditione
3. You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the On timer setting On indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator 3 will be displayed on the indoor unit display On timer setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the On indicator on the remote controller display and the Timer indicator on the indoor unit display gt Press the Timer button gt select On gt press the lt or button gt Cancel set the timer to 1 press the SET button gt Press the Power button Remote controller display Additional options available in On Off timer mode When the remote controller is on You can select from Auto Cool Dry Fan Heat AR JO gt freno You can adjust the temperature in Auto Cool Dry Heat AR JQ mode A Fan You can adjust the fan speed in Cool Fan Heat ARK JQA gt x mode NA When On timer setting is completed the set status will be displayed for 3 seconds and then only On indicator will remain on the remote controller display thereafter Ifyou press the Power button on the indoor unit after setting the On timer from the remote
4. 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness I Periodical checks Refer to the following chart to maintain the air conditioner properly Type Description Every 2 weeks Every 3 months Every 4 months Once a year Indoor unit Clean the Full HD filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 This check mark requires checking the indoor outdoor unit periodically Follow the description to maintain the air conditioner properly CAUTION 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the installation part in the manual English 30
5. C within the range of 16 C 30 C Gs Fan speed will be adjusted automatically according to the good sleep mode Fan J b a M KG However If you select good sleep mode while heating operation is on you can adjust fan speed When the good sleep mode is on In Cool mode Air flow direction will be adjusted automatically In Heat AR JQ mode Adjusting air flow direction is available Temperature and fan speed change in good sleep mode Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up Allows you to wake up from comfortable intermittent air and it makes you feel refreshed Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating AR JOx NOTE Ifthe set temperature is too low you may feel cold during sleep or catch a cold Optimal operation hour of good sleep mode is 8 hours Therefore if the time is set too short or long you may not feel as comfortable as you would expect Ifthe good sleep mode is set over 5 hours Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically e When the On timer and the good sleep function is set simultaneously the air conditioner will only apply the function that was set later English 20 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 20 KY 2 17 2015
6. To avoid drain plug from contacting the ground secure gap between the caomon ground and the bottom surface of the outdoor unit Drain plug Drain hole NOILVTIVISNI ZO Bottom surface of outdoor ait 2 Connect a drain hose to the drain plug z Drain hole TZ J Drain plug Drain hose 3 Ensure that condensation draining is adequate Snow proof hood Inareas with heavy snow fall piled snow could block the air intake To avoid this incident install a frame that is higher than estimated snow fall In addition install a snow proof hood to avoid snow from piling on the Estimated __ outdoor unit noy fall Frame Evacuating the connected pipes The outdoor unit is loaded with sufficient R 410A refrigerant Do not vent R 410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a Global Warming Potential GWP 2088 You should evacuate the air in the indoor unit and in the pipe If air remains in the refrigerant pipes it affects the compressor It may cause reduction of cooling capacity and malfunction Use Vacuum Pump as seen in the picture When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure
7. make the Fast indicator blink and press the SET button Fast function is only available in Cool mode NOTE Vertical Horizontal air swing can be adjusted Set temperature and fan speed cannot be adjusted If the Fast function is selected while 2 Step Cooling Comfort Single user good sleep function is on corresponding function will be cancelled Remote controller display Using the Comfort function You can set the Comfort function to provide mild cooling When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Q C or Options button until Comfort indicator starts to blink 3 Press the SET button to set the Comfort function Comfort gt Comfort indicator will be displayed on the remote controller display and Comfort function will begin gt Press the Options button gt Press the lt C or Options button to C I EK make the Comfort indicator blink and press the SET button e Comfort function is only available in Cool mode Vertical Horizontal air swing can be adjusted Set H pre Set temperature can be adjusted but fan speed cannot be adjusted TT F Ifthe Comfort function is selected while 2 Step Cooling Fast Single user good sleep function is on corresponding function will be Comfort cancelled Remote controller display English 22 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 22 KY 2 17 2015 2 56 13 PM Usi
8. Disconnect tubing After disconnection protect valves and tubing ends from dust gt Compressor damage may occur if run at a negative suction pressure English 52 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 52 KY 2 17 2015 2 57 06 PM Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory After checking for gas leaks in the system insulate the pipe hose and cables Insulation Then place the indoor unit on the installation plate 1 To minimise condensation problems wrap foam insulation as shown in the O O figure on a part without insulation on the end of the pipes 2 Wind the pipe assembly cable and drain hose with vinyl tape Pipes 3 Place the bundle the pipe assembly cable and drain hose in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit Installation F a i plate 4 Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place Connecting wires 4 Make sure pipe does not move when you install the indoor unit on Drain hose caution aN installation plate 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps optional Fixing the outdoor unit in place Install the outdoor unit in level on a stable base to help avoid the generation of noise and Vinyl tape 5 NOILVTIVISN
9. Turbo B Dry mode is only available in the cooling mode NOTE English 16 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 16 D 2 17 2015 2 55 45 PM Adjusting the air flow direction This function will allow you to adjust the air flow direction vertically and or horizontally Press the or button to make air flow blades vertically and or horizontally Vertical air flow Horizontal air flow gt Tokeep the air flow direction in a constant direction press the or button again The air flow blade s will stop the movement gt Ifyou adjust the vertical air flow blade manually it may not close completely when you turn off the air conditioner 1 gt Ifyou adjust the horizontal air flow blade timer options Settings 0p settings manually it may not operate normally NOILINNIJISYA ZO Auto ME KI Remote controller display Remote controller display Adjusting the air flow direction is not available in good sleep mode while it is in note cool mode However you can adjust the air flow direction in good sleep mode while it is in heat AR JQ mode English 17 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 17 KY 2 17 2015 2 55 48 PM Setting the On Off timer I Setting the On timer When the air conditioner is off 1 Press the Timer button to select On On indicator will keep blinking and you can set the time 2 Press the button to set the time
10. 2 56 02 PM 2 Step cooling function 2 Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Q or Options button until 2 Step indicator starts to blink 3 Press the SET button to set the 2 Step Cooling function SNOILdO Y0 2 Step 2 Step indicator will be displayed on the remote controller display and 2 Step Cooling function will begin gt Press the Options button gt Press the lt 5 or Options button to C I pi make the 2 Step indicator blink and press the SET button Remote controller display English 21 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 21 KY 2 17 2015 2 56 04 PM Using the Fast function You can set the Fast function to provide fast and powerful cooling When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Q or Options button until Fast indicator starts to blink 3 Press the SET button to set the Fast function Fast gt Fast indicator will be displayed on the remote controller display and Fast function will begin gt Press the Options button Press the 2 or Options button to C I i
11. 22 Diameter of the screw 7 16 20UNF R 410A Diameter of the screw 1 2 20UNF 9 639 a 9 52 20 25 612 70 25 30 10 12 Tightening torque for charging port cap Refer to the table 615 89 ira 019 05 35 40 To check for gas leaks on the outdoor unit 1 Nem 10 kgf cm Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector Leak test with nitrogen before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R 410A Leak test after opening valves Before opening valves discharge all the nitrogen from the system and create vacuum according to page 49 51 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the refrigerant connections for unit repair removal or disposal Pump down is an operation intended to collect all the system refrigerant in the outdoor unit This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere gt Shut off the liquid valve with the Allen wrench gt Turn the system on in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last stop gt After 2 minutes of operation shut the suction valve with the same wrench gt Turn the system off and switch mains supply off gt
12. C 15 C 52 C Relative humidity 80 or less z ARX XJQX Heating 27 C or less 5 C 24 C ARX JQX ARXJR Dry 18 C 32 C 15 C 52 C kai ARX JQX gt If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed gt If the outdoor temperature goes down to 5 C heating capacity may decrease as much as 60 70 of specified capacity according to the using conditions AR JOXX I Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description Against cold air The internal fan will be off to prevent cold air when the heat pump is heating ARHHJQAHH The internal fan will be off to defrost ice when the heat pump is heating oe oe Vertical air flow blade will be closed during defrost cycle and it will open again during heating operation after defrost cycle Protect compressor The air conditioner does not start operating immediately to help protect the compressor of the outdoor unit after it has been started Ifthe heat pump is operating in Heat mode Defrost cycle is actuated to help remove frost from an outdoor unit that nome May have deposited at low temperatures The internal fan is switched off automatically and restarted only after the defrost cycle is completed ARX JQ I Smart install gt Th
13. KE When installing more than 1 outdoor unit Unit mm When the air outlet is towards the wall When 3 sides of the outdoor unit are blocked by the wall U U U o _ 5 o o o 5 Q T TT Jo C Q az C V V V a 300 or more 600 or more 6000rmore 600 or more English 36 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 36 KY 2 17 2015 2 56 40 PM When the walls are blocking front and the rear side of the outdoor units Lo V o TT C V t 300 or more more 600 or more 600 or nor 1500 or When front and rear side of the outdoor unit is towards the wall af e Unit mm When the upper part of the outdoor unit and the air outlet is opposite the wall 500 or more 500 or more hh p J k J kh 1500 or 600 or 3000 or 3000 or 200 or more more more more more 300 or more B 300 or more NOILVTIVISNI ZO Ifinstallation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner B The number of each accessory is indicated in parentheses NOTE Accessories in the indoor unit case Installation Plate 1 05 frame Remote controller 1
14. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel I Removing the Cover panel Before mounting the indoor unit The bottom panel fits the main body using the side center and bottom hooks as shown Unlock the side hooks first and then unlock the center and bottom hooks Check the location of the hooks before removing the cover panel lt Unfasten the screw gt gt Location of the hooks on the central part Number and location of the hooks Center hook Bottom hook po m Center hooks KJ Bottom hooks For specific Hook location and quantity please refer to cover panel with indicating arrows based on physical goods English 40 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 40 KY 2 17 2015 2 56 51 PM Disassembling Assembling the Cover panel for indoor unit installation gt Removing the hooks on the side gt Removing the hooks on the central part NOILVTIVISNI ZO Caution fragile 3k Caution fragile Gently press the both side of the cover Use both hands panel inwards D and release the Release each hook by pushing it up at an angle hooks on both sides Assembling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pipes and drain hose Lock th
15. ambient air v lighting in Auto clean mode English 25 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 25 KY 2 17 2015 2 56 28 PM Setting the Beep sound Beep sound from the indoor unit can be muted 1 Press the Settings button 2 Press the C or Setting button until Beep indicator starts to blink 3 Press the SET button to mute the beep sound Genine 3 seconds after setting Beep sound function Beep indicator on the remote controller display will disappear and Beep sound function will begin Resetting the Filter clean reminder When Filter clean reminder CF lights up on the indoor unit display clean the filter and reset the reminder by following this instruction 1 Press the Settings button 2 Press the lt X or Setting button until Filter Reset indicator starts to blink 3 Press the SET button to reset Filter clean reminder 3 seconds after setting Filter clean reminder function Filter Reset indicator on the remote controller display will disappear and CF indicator on the indoor unit display will disappear Setting the Display option Display lighting can be adjusted by following this instruction 1 Press the Settings button 2 Press the lt gt or Setting button until Display indicator starts to blink 3 Press the SET button to set the display status tio 3seconds after setting Display function Display indicator on the remote controller display will
16. be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely English 33 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 33 KY 2 17 2015 2 56 36 PM Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines Always disassemble the electric lines before the refrigerant tubes gt Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer gt After completing the installation always carry out a functional test and provide the instructions on how to operate the air conditioner to the user gt Donot use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires explosions or injuries To help prevent injury when accidentally touching the indoor unit fan install the indoor unit at least 2 5 m above the floor gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry gt Our units must b
17. controller Timer indicator on the indoor unit display will disappear and the On timer will be cancelled Even though the On timer is cancelled On indicator on the remote controller will remain displayed When the On timer is set while the air conditioner is off Timer indicator will be displayed and remain on until the On timer turns on English 18 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 18 KY 2 17 2015 2 55 52 PM Setting the On Off timer I Setting the Off timer When the air conditioner is on 1 Press the Timer button to select Off Off indicator will keep blinking and you can set the time 2 Press the button to set the time You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the Off timer setting Off indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator 4 will be displayed on the indoor YAWIL 0 Auto unit display Off timer setting will be cancelled if you don t press the SET button within Set J lt 10 seconds after setting the time Therefore check for the Off indicator on the Off F eb remote controller display and the Timer indicator on the indoor unit display gt Press the Timer button gt select Off gt press the Jor C button
18. disappear and indoor unit display will be turned off SET gt Press the Setting button gt Press the lt gt or Setting button to make the Display indicator blink and press the SET button Display indicator on the remote controller display will disappear and the indoor unit display will be turned on again Cancel Display option cannot be set when the air conditioner is off Note f you turn off the display when the Virus doctor function is in operation with air conditioner operation the indoor unit display will be turned off at the same time Operation or timer display will not be turned off by the display off function English 26 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 26 K 2 17 2015 2 56 32 PM Cleaning the air conditioner Make sure to turn off the power of the indoor unit and cut off CAUTION the power supply before cleaning the air conditioner I Cleaning the indoor unit gt Clean the product with a tepid damp cloth SHIHLO 90 gt Remove the dust accumulated in the gap of the product with a soft brush Contact the service center when you clean the indoor unit note heat exchanger because it needs to be disassembled Do not clean the display using alkaline detergent CAUTION Do not use sulfuric acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the
19. in Cool mode Auto Low bd Med High kri Turbo can be selected Vertical Horizontal air swing can be selected English 23 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 23 KY 2 17 2015 2 56 18 PM Using the Virus Doctor function This function will produce positive ions and supply them into the airflow When the air conditioner is operating 1 Press the Options button 2 Press the Q Cor Options button until 2 9 indicator starts to blink 3 Press the SET button to set the Virus Doctor function 882 indicator will be displayed on the remote controller display and Virus Doctor function will begin gt Press the Options button gt Press the lt 2 or Options button to E I ote ange make the 2 5 indicator blink and press the SET button Virus Doctor function can be selected while Auto Cool Dry Fan Heat AR JQ mode is on Set temperature can be adjusted There will not be much difference on energy consumption and Auto Set jam C a 1 c as a j operating noise when the Virus Doctor function is selected additionally while the other function is on When the Virus Doctor function is selected with other operation mode pressing the Power button will stop the operation Remote controller display When the air conditioner is not in operation 1 Press the Options button 2 When the 2 9 indicator blinks press the SET butto
20. the temperature at 30 C ARK JOXX Approximately 3 5 minutes later outdoor unit will start to operate and the note Cool or Warm AR JQ3 air will blow out After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check gt Inlet air temp Outlet air temp From 10 C to 12 C indicative delta T Heating mode indoor unit check gt Outlet air temp Inlet air temp From 11 C to 14 C indicative delta T ARJO In heating mode the indoor fan motor can remain off to avoid cold air blown into conditioned space ARX JQX 3 Press the Air swing button and check the following gt The airflow blades work properly 4 Press the Power button to stop the operation When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE place Pump down procedure when removing the product 1 Turn on the air conditioner and select Fast Cool mode Please let the compressor run for more than 5 minutes If the compressor does not operate for more than 5 minutes due to protection control wait about 2 minutes and then carry out the next procedure 2 Release the valve caps on High and Low pressure side 3 Use L wrench to close the valve on the high pressure side 4 After approximately 2 minutes close the valve on the low pressure side 5 Stop operation of the air condition
21. x 25 Tapped Screws 6 B If these accessories are supplied they will be in the accessory box NOTE I Tools required for installation General Tools Vacuum Pump Backward flowing prevention Manifold Gauge Stud Finder Torque Wrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill LWrench Measuring Tape Tools for test operations Thermometer Resistance Meter Electroscope Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit Therefore before fixing the installation plate to a wall or a window frame you must determine the position of the 65 mm hole through which the cable pipe and hose pass to connect the indoor unit to the outdoor unit When facing the wall the pipe and cable can be connected from the Direction of pipe Right A Left B Underside_right C Rear_right or left D A You can install the refrigerant pipe in the left right bottom or the rear side of the indoor unit canon If changing the pipe direction from left to right do not drastically bent it but slowly turn it in the opposite direction as shown Otherwise the pipe may be damaged in the process English 38 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 38 KY 2 17 2015 2 56 45 PM 1 Disassemble th
22. 9 7 mm English 45 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 45 KY 2 17 2015 2 56 57 PM Cutting or extending the pipe 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Inclined Damaged Surface Cracked Uneven Thickness 6 Align the pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Indoor outlet pipe Flarenut Outer Diameter Torque Nem kgf cm 66 35 mm 14 18 140 180 69 52 mm 34 42 350 430 612 70 mm 49 61 500 620 Connecting pipe 615 88 mm 68 82 690 830 Excessive torque can be cause of gas leakage If extending pipe by welding brazing please ensure nitrogen is used NOTE during welding brazing process The joint must be accessible and serviceable The holder system is detachable as shown Va IN a Kg Holder system detachable N 7 For further details on how to connect to the outdoor unit and evacuate the air refer to page 49 51 Tighten the flare nut with torque wrench according to specified method CAUTION If the flare nut is over tightened the flare may break and cause refrigerant gas leakage Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose t
23. AR JRSD Series AR JQSD Series 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product D ITP MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 1 KY 2 17 2015 2 55 07 PM Features of your new air conditioner I 2 step cooling 2 step cooling function will quickly cool the room to reach the set temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing I Fast cooling If you want the strong and cool air just select Fast function It will get you the strongest air I Comfort cooling If you want the comfortable and refreshing air Comfort function will spread the cool air indirectly to you so that you can stay comfortable I Single User Use Single User function when you are alone at home This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode I Easy Filter There is no grille to remove before separating the filter from the air conditioner Therefore filter can be cleaned easily more frequently Frequent filter cleaning will prevent dust from entering into the product or accumulating on the filter good sleepfunction good sleep function will allow you to have deep good night s sleep by adjusting the temperature fan speed and air flow direction I Smart Install When the installation is done your produc
24. EL AR24JRSDBWK MG AR24JQSDBWK MG CLIMATES CLASS TI T3 T T3 COOLING 22000 Btu h 18000 Btu h 22000 Btu h 18000 Btu h CAPACITY HEATING H1 z 6300W RATED VOLTAGE amp FREQUENCY 230V 60 Hz COOLING 85A 95A 85A 95A RATED CURRENT HEATING H1 87A COOLING 1910W 2170W 1910W 2170W RATED POWER INPUT HEATING H1 s 1960W EER COP COOLING 11 52 8 29 11 52 8 29 Btu hr Watt HEATING H1 3 21 W W TYPE R 410A REFRIGERANT CHARGE 12009 42 32 oZ 2000 g 70 54 oz ANNUAL ENERGY CONSUMPTION 5157 kwh yr 5157 kwh yr NC 29 C 27 C 20 C 29 C 20 C INDOOR 19 C 19 C 19 C 15 C 19 C 15 C TEMPERATURE 35 C s 46 C 35 C 7C 46 C 7C OUTDOOR 24 C 5 24 C 24 C 6 C 24 C 6C INDOOR 145 kg 145 kg NETWEIGHT OUTDOOR 525 kg 64 0 kg INDOOR 1065 x 301 x294 mm 1065 x 301 x294mm DIMENSIONS OF THE UNIT OUTDOOR 880x793 x310 mm 880x 967 x 320 mm COUNTRY OF ORIGIN CHINA MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 11 English 11 2 17 2015 2 55 27 PM Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model I Main parts Room temperature sensor Air filter T Air intake Virus Doctor Air flow blade up and down Air flow blade left and right I Display gt up L L Temperature indicator Fil
25. I ZO vibration especially when installing the unit close to a neighbor X mm If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an a Aa appropriate support wall or ground gt 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air out LG abala properly 3 si F M Model X Y 2 Fixthe outdoor unit in level to an appropriate support using anchor bolts HH18 24JR HHK J 660 340 3 Ifthe outdoor unit is exposed to strong winds install shield plates around the outdoor IK1BIQIK unit so that the fan can operate correctly FK24IOAK 645 340 NOTE I Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rack and outdoor unit Install the rack close to the column as much as possible Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall Soft rubber designed to cut off vibration from rack to wall not supplied with product English 53 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 53 KY Designed to cut off residual vibration from outdoor unit to rack not supplied with product 2 17 2015 2 57 07 PM Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions Execute Smart Install mode
26. V AAA 2 Insert two AAA batteries type batteries Check and match the and signs accordingly Make sure you have inserted the batteries in correct position 3 Close the cover by place it back to its original position When you do not use the remote controller for long time You should hear click sound when the cover is locked properly remove the batteries from the remote controller and store it Storing the remote controller The signal may not be received properly if electronic fluorescent lamps such as inverter fluorescent lamps are operating in the same space NOTE lf other electrical products operate by the remote controller call your nearest contact center Correct disposal of batteries in this product X Lo Applicable in countries with separate collection systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium orlead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system English 14 MG
27. _BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 14 KY 2 17 2015 2 55 40 PM Basic function Basic operation is an operation mode that can be selected by pressing the Mode button I Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature I Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season NOILINNIJISYA ZO If current outside temperature is much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness I Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To activate the Dry mode set temperature on the remote controller should be lower than indoor room temperature I Fan Fan mode can be selected to circulate your room Fan mode will be helpful to refresh the stale air in your room I Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperature is extremely low Use an addit
28. after installation 1 Check the installation status of the air conditioner 1 Check the power supply service valve if it s open power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Press the SET Mode Power button simultaneously for 4 seconds gt Smart Install mode can be operated only with the supplied remote controller gt During the Smart install mode procedure remote controller cannot be operated Remote controller may be different image functions depending on the model English 54 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 54 KY 2 17 2015 2 57 08 PM 2 Smart Instal 88 Display Pr mode in progress ogress will be displayed in 0 99 LED Display Indicator on the indoor unit display will blink in sequence and then all indicators will blink This will be repeated TYPE 88 Display LED Display LILI Indoor unit indicator Ll L O o 3k Display may be different depending on the model 3 Smart Install mode will end 1 2 Smart Install mode will take approximately 7 13 minutes Actual time may be different depending on the model When Installat
29. alls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line B Failure to do so may result in electric shock fire and explosion gt Make sure to use a socket outlet with ground FORINSTALLATION A CAUTION Install your appliance on a level and hard floor that can support its weight gt Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly KY B Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly gt The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage FOR POWER SUPPLY WARNING When the circuit breaker is damaged contact your nearest service center Do not pull or excessively bend the power line Do not twist or tie the power line Do not hook the power line over a metal object place a heavy object on the power line insert the power line between objects or push the power line into the space behind the appliance B This may result in elec
30. amp IM_DB68 05189A indd 43 KY 2 17 2015 2 56 56 PM Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to 1501337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant Ashort pipe is already fitted to the air conditioner You may need to extend the pipe using the assembly pipe optional The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear 1 Cut out the appropriate knock out piece A B C on the rear of the indoor unit unless you connect the pipe directly from the rear 2 Smooth the cut edges 3 Remove the protection caps of the pipes and connect the assembly pipe to each pipe Tighten the nuts first with your hands and then with a torque wrench applying the following torque B Ifyou want to shorten or extend the pipes refer to page 45 46 NOTE 4 Cutoff the remaining foam insulation 5 If necessary bend the pipe to fit along the bottom of t
31. aste NADAL BANO NPA DAANAN AETA GNG PG ka NA 34 Accessories 065 Var Fixing the installation plates secrete einingin ea nanea nE EAE E AEE AE E E A 38 Disassembling Assembling the Cover panel for indoor unit installation 2 2iasias sss nas sannan nansannanaannanannannannannannnannaii 40 Connecting theiasserm bly Cables mana RRR RRR a 42 installing and connecting the assembly pipe of the indoor unit 6 cece eee cece ence eect bene ENG ENGR ENE KAEN E ta GNG teen ene eee nena eee 44 Evacuating the indoor unit 2 45 Cuttingiorextending the pPeossguaus soap kkk kr 45 nstalling and connecting the drain hose of the indoor unit adn dab G Tabs TO cent nent ee ede neta O R RR R a kaa 46 Changing direction iof the drainihOseiicscevicssicsssictetmossidvaumca warns NAGBANGGAAN NANNING TR 48 installing and connecting the drain hose of the outdoor unit ssasas aasawa dene NN GNG NA ENG eee A Eiser Ene E wera 49 Evacuatingithe connected Pipe S ssi ora ANAND NANG S AL TR wae sasmucantinbuevnenedo O BALAYAN 49 Performingithe gasleakite5ts eenia kv in akri EE DEENEN mGA x 52 Fixing the iIndoorunitin plate anakan 0NG NING NANANA NG NGANGA KINAIN NANALANGIN BA pa BANGIN 53 Fixing the outdoor unitin Places snaps A Saa l Ra S L vile R R Rl 53 SmartinstallMo des ss a R SR RRR 54 Finalicheckand trial operationys vsaka E T GNG NATAN NANA KA KG KN R AA NAA NAPADALA ALA 56 Pump down procedure when removing th
32. auge 6 Seta valve cork of liquid and gas service port to the open position Vacuum Liquid service port _ Pump lt High pressure gt Backward flowing prevention I Adding Refrigerant Add refrigerant charge according to table below If you use a pipe longer than 4 m X XY24x gt or 5 m XX 189K Model A A g of refrigerant R 410A must be added for each extra meter HH18 24HH 20 If you use a pipe shorter than 4 m X X 24 H or 5 M XH 18 HH The evacuating time is normal Refer to the Service Manual for further details The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor caution Always contact the service center or a professional installation agency for product installation English 50 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 50 KY 2 17 2015 2 57 05 PM I Charging the refrigerant under conditions of liquid by using a liquid pipe R 410A is a mixed type of refrigerant It is necessary for recharging under conditions of liquid When recharging refrigerant from the refrigerant cylinder to the equipment follow the instructions below 1 Before recharging check whether the cylinder has a siphon or not o There are two ways to recharge the refrigerant n Cylinder with siphon Cylinder without siphon gt Siphon g gt Charge the refrigerant standing the gt Charge the refrigerant turning the cyli
33. autions listed below because they are essential to guarantee the safety of the equipment Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components Verify that installation and testing operations are performed by qualified personnel e Verify that the air conditioner is not installed in an easily accessible area General information NOILVTIVISNI ZO gt Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings gt Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred gt This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The manufacturer shall not be responsible for damages arising from the use of non compliant units gt This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Electromagnetic Compatibility Directive 2004 108 EC of the European Union gt The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper c
34. ble for their safety Children should be supervised to ensure that they do not play with the appliance NOILVYVdIYd LO FORCLEANING WARNING Donotclean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance B This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops P Failing to do so may result in electric shock or fire FORCLEANING A CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges gt This should be done by a qualified technician please contact your installer or service center Do not clean the inside of the air conditioner by yourself P For cleaning inside the appliance contact your nearest service center gt When cleaning the internal filter refer to the descriptions in the Cleaning the air conditioner section P Failure to do may result in damage electric shock or fire English 9 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 9 KY 2 17 2015 2 55 21 PM Checking before use I Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Mode Indoor temperature Outdoor temperature Indoor humidity Remark 4 ARKHJRH Cooling 16 C 32
35. dd 19 KY 2 17 2015 2 55 54 PM good sleep mode For a comfortable sleep the air conditioner will operate in 3 stages in order of Fall asleep gt Sound sleep gt Wake up stage When the air conditioner is operating in Cool Heat ARJQX mode 1 Press the Timer button to select 28 indicator will keep blinking and you can set the time 2 Press the button to set the time You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 12 hours Time can be set from minimum 30 minutes to maximum 12 hours Default time setting for the good sleep mode is 8 hours 3 Press the SET button to complete the good sleep mode setting G indicator and the set time of the good sleep mode will be displayed on Cool the remote controller display Set eo Timer indicator will be displayed on the indoor unit display good sleep mode setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the t indicator on the remote controller display and the Timer indicator on the indoor unit display off olun r P gt Press the Timer button gt select gt press the lt Jor C button gt Cancel An set the timer to yn press the SET button Remote controller display Additional options available in good sleep mode Temp You can adjust the set temperature by 1
36. drain hose with a shield 3 Fit the drain hose into 1 of 2 drain hose holes then fix the end of the drain hose tightly with a clamp you do not use the other drain hose hole block it with a rubber stopper NOTE 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose rotate and insert the drain hose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected there is no water leakage Drain hose hole 5 Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose Then Use vinyl tape to wrap the each side of connection by 20 mm ormore ormore TE 40 45 mm aye Drain hose Extension 20mm 20mm Drain hose ain ose Vinyl Tape Foam Insulation English 47 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 47 D 2 17 2015 2 57 01 PM Installing and connecting the drain hose of the indoor unit 6 Pass the drain hose under the refrigerant pipe keeping the drain hose tight 7 Pass the drain hose through the hole in the wall Check if it slants Shield downwards as seen in the picture ma BOR 8 Using natural drainage method check the drainage is normal Rl KU LULU Drain hose Extension drain hose The hose will be fixed permanently into position after finishing the installation and the gas leak test refer to page 53 for further details Make s
37. e cover panel as described in page 40 41 2 Remove the Hanger plate from the indoor unit 1 Unscrew 2 screws that fixes the Hanger plate to the indoor unit 2 Push the hooks on the bottom part of the indoor unit up to release the installation plate from the hooks that holds it 3 Pull the installation plate to release it completely from the indoor unit NOILVTIVISNI ZO 3 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards Pipe hole 065 mm Unit mm Model A B D KKIBNAKK 33 110 110 33 Make sure to drill only one hole after choosing the caution direction of the pipe 4 Fix the indoor unit If you fix the indoor unit on a wall 1 Fixthe installation plate to the wall giving attention to the weight of the indoor unit Plastic Yv Anchor Ifyou mount the plate to a concrete wall using plastic anchors make sure that gaps Sommf IA note between the wall and the plate created by projected anchor is less than 20 mm L Z If you fix the indoor unit on a window frame 1 Determine the positions of the wooden uprights to be attached to the window frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attac
38. e installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available gt Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual gt Always verify that electric connections cable entry section of leads protections are c
39. e product cuns ona teen ence nett eden ANNE dense tees dene teens NN GNG teen ene ea esta eed 56 Packingiandiunpacking QuIde sssr irronneita nir ar A ENE nE E REEERE EEREN eE 57 How to conhect your extended power cables ssanie bA AEEA DS B EAEE NGA E r nr SA 58 English 3 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 3 KY 2 17 2015 2 55 09 PM Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Hazards or unsafe practices that may result in severe A WARNING personal injury or death Hazards or unsafe practices that may result in minor A CAUTION personal injury or property damage Q Follow directions Cut off the power supply N Do NOT attempt O Do NOT disassemble L Make sure the machine is grounded to prevent electric shock FOR INSTALLATION WARNING Q Use the power line with the power specifications of the product or higher and use the power line for this appliance only In additio
40. e side center and bottom hooks in this sequence Tighten the bottom panel with the screws and close the screw holes with their cap lt Fasten the screw gt lt Assemble the Cap screw gt English 41 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 41 KY 2 17 2015 2 56 54 PM Connecting the assembly cable I Cable specification Model Power cable Interconnection cable Type GL HH18 HAH 3G x 2 5 mm HOSW F 4G x 1 5 mm HO7RN F 25 A OK 24K 3G x 2 5 mm HOSW F 4G x 2 5 mm HO7RN F 25A e Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to the power supply it must be incorporated in a wire with a contact opening of 23 mm Use shield cable Category 5 less than 50pF m for noisy environmental site Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord Code designation IEC 60227 IEC53 CENELEC HOSWV F IEC 60245 IEC 66 CENELEC HO7RN F I Connecting the cable Electrical work 1 For electrical and earth works comply with the technical standards of electrical installations and the the wiring regulations of the Local wiring regulations 2 Tighten the terminal block screw to 1 2 1 8 Nem 12 18 kgf cm 3 Precautions when connecting terminal blocks of the indoor unit gt Before connecting make sure the connecting part of the terminal socket is facing u
41. e that restrains motor H H display and all LED 1 Re set options blink O O O EEPROM Option error E i626 ib3 1 Check if the service valve is completely open Refrigerant flow blocking 2 Check if there s any blockage in the refrigerant pipe E 1 2 2 o O K Error which connects indoor and outdoor unit 3 Check for refrigerant leak O o 1 Checkif sufficient amount of additional refrigerant was charged for the pipe length that exceeds 7 5 m 2 Check for refrigerant leak between valve and pipeconnection O 0ff Blinking 0n English 55 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 55 2 17 2015 2 57 11 PM NOILVTIVISNI ZO Final check and trial operation To complete the installation perform the following checks and tests to ensure that the air conditioner operates correctly Check the followings Strength of the installation site Tightness of pipe connection to detect gas leak Electric wiring connection Heat resistant insulation of the pipe Drainage Grounding conductor connection Correct operation follow the steps below 1 Press the Power l button and check the following gt The indicator on the indoor unit lights up gt The airflow blade opens and the fan gears up for operation 2 Press the Mode button to select Cool or Heat AR JQ mode P In Cool mode use Temp hr or button and set the temperature at 16 C B In Heat mode use Temp hr or button and set
42. er by pressing the Power button on the indoor unit or remote controller 6 Disconnect the pipes English 56 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 56 KY 2 17 2015 2 57 12 PM Packing and unpacking guide I Indoor unit WN s y wn y Packing the unit as below procedure Put the indoor unit onto the packing case Assemble cushion both side of indoor unit Left and Right Seal the packing case Unpacking the unit as below procedure Open the packing case Take out the both side of cushion Left and Right Move the set from the packing case I Outdoor unit gt 1 2 3 Packing the unit as below procedure gt 1 Putthe outdoor unit onto the cushion bottom di 3 4 Put the cushion top onto the outdoor unit Put the packing case from the top of set Seal the packing case Unpacking the unit as below procedure Take out the packing case from the set Take out the cushion top Move the set from the cushion bottom English 57 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 57 KY NOILVTIVLSNI ZO 2 17 2015 2 57 12 PM How to connect your extended power cables Items to prepare compressor and insulation tape should be prepared by an installation technician Tools Crimping pliers Connection sleeve mm Insulation tape Contraction tube mm Spec MH 14 20x07 0 HxOD Width 18 mm 50x 8 0 LxOD Shape e 1 As shown in the figure peel off the shie
43. g the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Refer to the picture below NOILVTIVLSNI ZO B Each wire is labeled with the corresponding terminal number NOTE 5 6 7 8 9 Pass the other end of the cable through the 65 mm hole in the wall Close the connector cover by tightening the screw carefully Close the cover panel Remove the terminal board cover on the side of the outdoor unit Connect the cables to the terminals as seen in the picture 7 Indoor unit Indoor unit Outdoor unit Outdoor unit Also circular terminal must be matched with screw size in terminal block caution After connecting the cables make sure terminal numbers on the indoor outdoor unit matches Please ensure that Power amp Communication cables are separated they must not be in the same cable 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully Connect the wires firmly so that wires can not be pulled out easily warning If they are loose it could cause burn out of the wires Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 42 English 43 MG_BETTER_ON amp OFF_A3050_IB
44. gn substances from getting into the pipes during note installation do NOT remove the caps completely until you are ready to connect the pipes NOILVTIVLSNI ZO A The remaining air in the Refrigeration cycle which contains moisture caution May cause malfunction on the compressor Always contact the service center or a professional installation agency Unscrew the for product installation Pipes caps Cutting or extending the pipe The length of the pipe can be Extended up to see table page 35 Shorten up to see page 35 A If you need a pipe longer than 4 meters XX24 gt or 5 meters XX18AX caution You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 If you want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges Pipe 90 Oblique Burr cutter 5 X A Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe CAUTION 4 Puta flare nut slightly into the pipe and modify the flare spies Outer Diameter D Depth A Flaring Size B pago 45 6 35 mm 1 3mm 8 7 9 1 mm t2 Br 69 52 mm 18mm 128 13 2mm SS 612 70 mm 2 0mm 16 2 16 6 mm Mosas 15 88 mm 2 2mm 19 3 1
45. gt Cancel set the timer to JH press the SET button gt Press the Power button Off timer may not work depending on the On Off status of the indoor unit and the On Off status of the indicator on the remote controller display Only the latest setting timer will be applied between the On Timer Off Timer and good sleep Off timer functions After setting the timer the set time will be displayed for 3 seconds before it disappears If Timer function is used in Heating mode Air conditioner work into former mode ARX JR series Remote controller display Combining On Timer and Off Timer When the air conditioner is off When the air conditioner is on When set time on On timer is shorter than Off timer When set time on On timer is longer than Off timer Ex On timer 3 hours Off timer 5 hours Ex On timer 3 hours Off timer 1 hour The air conditioner will turn on after 3 hours from the The air conditioner will turn off after 1 hour from the moment you have set the timer and the air conditioner will moment you have set the timer and turn on after 2 hours remain on for 2 hours and then turn off automatically from the moment it was turned off Set time for the On timer and the Off timer should be different from each other NOTE When the On timer and the Off timer is set setting can be cancelled by pressing the Power button English 19 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A in
46. h the installation plate to the wooden upright using tapping screws If you fix the indoor unit on a gypsum board 1 Use stud finder to find out locations of the studs 2 Fix the plate hanger on two studs Search for other spots if there are less than two studs or the distance between the studs are different from the caution Plate hanger Fix the installation plate without inclining to one side Make sure that a wall can withstand the weight of the product If you install the product in a place where it is not warning strong enough to withstand the product weight the unit could fall and cause injury I Assembling the hanger screw Use 2 screws to fix the indoor unit with hanger plate as shown in the picture English 39 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 39 KY 2 17 2015 2 56 48 PM Disassembling Assembling the Cover panel for indoor unit installation Please scan this OR code for detail video of indoor unit installation In order to install the indoor unit you must disassemble the cover panel first Please proceed following instructions to disassemble and assemble the cover panel Hooks on the cover panel may get damaged if you apply excessive force as you disassemble and assemble the cover panel Please follow the following instructions I Removing the screws Cover panel is assembled on the bottom part of the indoor unit as shown in the illustration and it is fastened with screws
47. he indoor unit Then pull it out through the appropriate hole gt The pipe should not project from the rear of the indoor unit gt The bending radius should be 100 mm or more 6 Pass the pipe through the hole in the wall gt Torque Outer Diameter Nem kgf cm 06 35 mm 14 18 140 180 69 52 mm 34 42 350 430 612 70 mm 49 61 500 620 615 88 mm 68 82 690 830 7 For further details on how to connect to the outdoor unit and evacuate the air refer to page 49 51 The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test note refer to page 53 for further details Tighten the flare nut with torque wrench according to specified method If the flare nut is over tightened the flare may break and cause refrigerant gas leakage DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable CAUTION English 44 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 44 KY 2 17 2015 2 56 56 PM Evacuating the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or forei
48. hrough the 65 mm hole drilled in the wall check the followings Wall Indoor unit Drain hose MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 46 N i l The drain hose must NOT slant upwards The end ofthe drain hose must NOT be placed under water English 46 x N At The drain hose must not be bent 2 17 2015 2 56 59 PM Installing and connecting the drain hose of the indoor unit After completing the installation of the drain hose pour water into ZT the drain pan to check t 5cm N p i ti i whether the hose is well ess Ditch drained Keep a clearance ofat least Do not place the end of the 5cm between the end ofthe drain hose in a hollow drain hose and the ground NOILVTIVISNI ZO 1 Correct connection 2 Incorrect connection EDETI ae SSI FE j STE quai Drain hose Pipe Drain hose Pipe Don t tie drain hose to the assembly pipe which may lead to water leakage CAUTION If the diameter of the connection hose is smaller than the product s drain hose water leakage may occur I Drain hose installation 1 If necessary connect the 2 meter extension drain hose to the drain hose 2 If you use the extension drain hose insulate the inside of the extension
49. inside of the refrigerant cycle abnormally high It may cause explosion and injury English 49 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 49 KY 2 17 2015 2 57 05 PM Evacuating the connected pipes 1 Connect each assembly pipe to the appropriate valve on the outdoor unitand Outdoor unit amp B tighten the flare nut Gas pipe side 2 Tighten the flare nut first with your hands and then with a torque wrench Liquid pipe side applying the following torque B Excessi b faasiesk Outer Torque H Excessive torque can be cause of gas leakage Diameter V Peka 06 35 mm 14 18 140 180 3 Connect the charging hose of the low pressure side of manifold gauge to a 69 52mm 34 42 350 430 gas service port as seen in the picture o1270mm 49 61 500 620 4 Open the valve of the low pressure side of manifold gauge counterclockwise 915 88mm 68 82 690 830 5 Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes gt Make sure that pressure gauge shows 0 1 MPa 76 cmHg after about Manifold gauge 10 minutes This procedure is very important to avoid a gas leak gt Close the valve of the low pressure side of manifold gauge clockwise Valve gt Turn off the vacuum pump gt Check for 2 minutes if there is any pressure change Gas service port lt Low pressure gt gt Remove the hose of the low pressure side of manifold g
50. ion is successful Smart Install mode will end with ringing sound and the air conditioner will be in standby status Error message will not be displayed on the indoor unit indicator and the remote controller and buttons on the indoor unit will work normally unit display 1 Take necessary measures when error occurs Refer to the service manual for necessary measures for each error that occurs CAUTION 2 Use the product after taking care of the error that occurs When installation is not successful Smart Install mode will end and error message will be displayed on the indoor Error indicator ESSA Above LED pattern is displayed when there s error is occurred on outdoor unit Check the LED display on outdoor unit for the details Lack of Refrigerant For Inverter model only LED Display g g LED 1 LED 2 LED 3 Error Measures to take by an installer Display BUTIG Communication Error 1 Check the connection wire between indoor and H O 0 between Indoor and outdoor outdoor unit whether the power cable and unit communication cable is crossed or not Error on indoor temperature 1 Check the connection of the connector Ei i O o O pla Error on indoor heat 1 Check the connection of the connector E ieee J K K O exchanger 1 Check the connection of the connector E H 5 u O O Q9 Error on indoor fan motor 2 Remove foreign substance Check for the caus
51. ional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently B Only Heating models have this function AR JQ series NOTE English 15 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 15 KY 2 17 2015 2 55 40 PM Basic function Press the button to turn on the air conditioner Press the button to set the operating mode Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat ARKJO2 gt Auto Cool Dry Fan Heat Set Set set c Set ec al p gt L E p P gt ILE C C Lt I A Press the button to adjust the temperature Auto You can adjust the set temperature by 1 C within the range of 16 C 30 C Cool You can adjust the set temperature by 1 C within the range of 16 C 30 C Dry You can adjust the set temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible Heat oC withi o o ARKKJOA KK You can adjust the set temperature by 1 C within the range of 16 C 30 C DN Press the button to set the desired fan speed 4 Auto Auto Cool Bl Auto AB Low AB Med BY High Bl Turbo Dry Auto Fan Bl Low ey Med High B Turbo Heat ARK JQX P Auto lt Low Med lt High 4B
52. lace an object near the outdoor unit that allows children to climb onto the machine gt This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people B Since this may be dangerous due to a lack of oxygen Open a window at least once an hour If any foreign substance such as water has entered the appliance cut off the power supply and contact the nearest service center P Failing to do so may result in electric shock or fire Do not attempt to repair disassemble or modify the appliance yourself P Do not use any fuse such as cooper steel wire etc other than the standard fuse Failing to do so may result in electric shock fire problems with the product or injury English 7 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 7 KY 2 17 2015 2 55 21 PM Safety precautions FOR USING AACAUTION Q Donot place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage example electrical appliances Check that the installation frame of the outdoor unit is not broken at least once a year P Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Donat stand on top of the appliance or place objects such as la
53. lds from the rubber wire Unit mm of the power cable Power cable provided by us Peel off 20 mm of the wire shields of the tube installed already J A After peeling off the tube wire you must insert a contraction tube CAUTION 2 Insert both sides of core wire of the power cable into the connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed 4 Wrap it with the insulation tape twice and position your Insulation tape contraction tube in the middle of the insulation tape p 5 Apply heat to the contraction tube to contract it Jomm Contraction tube tape Incase of extending the electric wire please DO NOT use a round shaped pressing socket 6 After tube contraction work is completed wrap it with the insulation tape to finish A Incomplete wire connections can cause electric shock or a fire 4 English 58 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 58 KY 2 17 2015 2 57 14 PM English 59 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 59 K 2 17 2015 2 57 14 PM QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT IRAN K ee a ie www samsung com iran support www samsung c
54. less places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3 m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated Install the unit horizontally Place where drained water does not become any problem Place with no plants especially climbing plants and where small animal can not access Outdoor unit should not be place higher than 2 4 m or directly under eaves for accessibility for service and OH amp S reasons NOILVTIVLSNI ZO vvvvvvvvvvrvy Avoid the following places to prevent malfunction of the unit canon Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas Outdoor Unit Outer wall 125 mm l r P 125 mm or or more more Indoor Unit amp Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape Refer to page 53 for further details Cut insulation to have rainwater drained Make an U trap A on the L m as maximum pipe length H meters A pipe which is connected and 3 m as minimum pipe length ma
55. n do not use an extension line gt Extending the power line may result in electric shock or fire P Do not use an electric transformer It may result in electric shock or fire gt If the voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company gt Failing to do so may result in electric shock fire explosion problems with the product or injury and may also void warranty on the installed product Install a Isolation Switch next to the Air Conditioner but not on the panels of the Air Conditioner and circuit breaker dedicated to the air conditioner Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock fire explosion problems with the product English 4 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 4 KY 2 17 2015 2 55 17 PM Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak 2 B This may result in electric shock or fire 3 Never install the outdoor unit in a location such as on a high external wall where it could fall 3 B Ifthe outdoor unit f
56. n to select the Virus Doctor function Pa CI C9 indicator will be displayed on the remote controller display and E Virus Doctor function will begin gt Press the Options button to make the ar indicator blink and press Cancel the SET button gt Press the Power button English 24 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 24 K 2 17 2015 2 56 24 PM Checking the usage time This function will displayed the accumulated operation time from the moment the air conditioner was turned on to the point when the usage function has been selected When the air conditioner is operating 1 Press the Settings button 2 Press the lt D or Setting button until Usage indicator starts to blink H 3 Press the SET button to check the usage time ma 3 seconds after setting usage time checking function Usage indicator on the remote controller will disappear Usage time will be displayed in hour 0 1 equals to 6 minutes Ex 0 1 6 minutes of usage 2 5 gt 2 hours and 30 minutes of usage 3 7 gt 3 hours and 42 minutes of usage Usage time will be displayed for certain period of time and it will automatically changed to indoor temperature Usage time will begin to accumulate when the air conditioner turns on and accumulated usage time will be reset when it turns off Initial value of usage time is 0 0 and maximum value is 99 Unit hour SONILLAS SO ENG When the air conditioner is n
57. nder cylinder upright upside down IfR 410A refrigerant is charged with gas the composition of the charged refrigerant changes and the note Characteristics of the equipment vary During the measuring operation of refrigerant quantity added use electronic scales If cylinder doesn t have syphon upset it English 51 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 51 KY 2 17 2015 2 57 06 PM Performing the gas leak tests Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate ly Test part for outdoor unit Test part for indoor unit Tightening torque for body cap gt Before inspecting the leakage use a torque wrench Refer to the table to close the cap for the service valve Comply with a tightening torque for each size of the diameter and e tighten the cap firmly to prevent any leakage b To check for any possible leakage insert inert gas into L Spindle the pipes connected to indoor outdoor units and F y A check the connection part of the indoor outdoor units Charging with soap lather or liquid for leakage test core p Outer Tightening torque Diameter i Body cap Nem Charging port cap mm Nem R
58. ng the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool mode When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Press the C 5 or Options button until Single user indicator starts to blink 3 Press the SET button to set the Single user function Single user Single user indicator will be displayed on the remote controller display Then _ _ will be displayed on the set temperature indicator part for few seconds and Single user function will begin When the Single user function is on vertical air swing will turn on automatically Ifthe current set temperature is lower than 24 C in Cool mode it will be automatically raised to 24 C SNOILdO Y0 Cool Set V Cancel gt Press the Options button Press the 7 or Options button to m ap make the Single user indicator blink and press the SET button Single user Single user function is only available in Cool mode NOTE If the Single user function is selected while 2 Step Cooling Fast Comfort good sleep function is on corresponding function will be cancelled Vertical air swing will remain on even after the Single user function is Remote controller display cancelled n k Additional options available in Single user function You can adjust the set temperature by 1 C within the range of 24 C 30 C
59. om sa support SAUDI ARABIA 8002474357 www samsung com sa_en support f 4 www samsung com ae support UAE 800 SAMSUNG 800 726 7864 wwwssamsung com ae ar support f F www samsung com ae support QATAR 800 CALL 800 2255 www samsung com ae_ar support a www samsung com ae support BAHRAIN 8000 GSAM 8000 4726 wwwsamsung com ae_ar support 1 t www samsung com ae support OMAN 800 SAMSUNG 800 726 7864 wwwsamsung com ae ar support JORDAN 0800 22277 www samsung com Levant support SYRIA 18252273 www samsung com Levant support EGYPT 0000 2680 www samsung com eg support MOROCCO 080 100 22 55 www samsung com n_africa support a i www samsung com ae support KUWAIT 183 CALL 183 2255 www samsung com ae_ar support NIGERIA 0800 726 7864 www samsung com africa_en support ALGERIA 021 36 11 00 www samsung com n_africa support PAKISTAN 0800 Samsung 72678 www samsung com pk support TUNISIA 80 1000 12 www samsung com n_africa support SOUTH AFRICA 0860 SAMSUNG 726 7864 www samsung com support GHANA BT www samsung com africa_en support BOTSWANA 8007260000 www samsung com support NAMIBIA 08 197 267 864 www samsung com support ZAMBIA 0211 350370 www samsung com support MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 60 KY 2 17 2015 2 57 14 PM
60. ompliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Choosing the installation location I Indoor unit gt ForWi Fi Air conditioner installation select indoor unit location near to wireless router In case Wi Fi signal strength weakened Smart APP may be disconnected depending on the Wi Fi signal strength gt Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram Wall that prevents vibration and is strong enough to hold the product weight Out of the direct sunlight 1 mor more away from the TV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights so that the remote controller can be operated well A place where the air filter can be replaced easily Don t install directly above electronics equipment as leaking water may cause damage if not serviced eg Computers TV etc English 34 vv vvvvvy MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 34 KY 2 17 2015 2 56 36 PM Choosing the installation location I Outdoor Unit Where it is not exposed to strong wind Well ventilated and dust
61. onnection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry KY Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy gt Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only The unit contains moving parts which should always be kept out of the reach of children gt Donot attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric shocks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws gt The air conditioner contains a refrigerant that has to
62. ot operating usage time will not be Indoor unit display NOTE displayed on the indoor unit display Using the Auto clean function Auto clean function will minimise the moisture inside of the indoor unit Activate this function to help provide you with clean air When the air conditioner is operating 1 Press the Settings button 2 Press the lt 2 or Setting button until Clean indicator starts to blink 3 Press the SET button to set the Auto clean function 3 seconds after setting Auto clean function Clean indicator on the remote controller display will disappear and Auto clean 1 Timer indicator will turn on the indoor unit display Auto clean function will be activated after the air conditioner stops operating Duration of the Auto clean function can be different depending on the previous operation mode used Auto cool Cool Dry mode 30 minutes Auto heat AR JO gt Heat ARXKJO x Fan mode 15 minutes gt Press the Setting button gt Press the lt C or Setting button to C I ange make the Clean indicator blink and press the SET button Indoor unit display When the operation mode is set during Auto clean function is activated the air conditioner will operate in chosen operation mode and the Auto clean function will be re activated when the operation stops During the auto clean function indoor fan will continue to run and air flow blade will remain open to expel
63. product or put any stickers on it They may damage the surface of the air conditioner I Cleaning the outdoor unit heat exchanger gt When dust accumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly gt Spray water to clean the dust Ifitis difficult to clean the outdoor unit heat exchanger on NOTE your own contact service center K KISS BI RRR RRR Q e Be careful with the sharp edges on the Heat exchanger CAUTION outdoor unit heat exchanger illustration may differ slightly depending on the models English 27 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 27 KY 2 17 2015 2 56 33 PM Cleaning the air conditioner I Removing the Air filter Air filter There is a hole on the bottom right side of the filter Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side Then pull it down to remove the filter from the main body I Cleaning the Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing A Remove the Air filter from the main body Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water E Inse
64. pwards Gu a The terminal There is no ring Upside down socketis damaged terminalto cover the wire gt There must be no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact B733 Either the screw is not fitted The terminal socket properly or there is a space between is upside down the screw and the ring terminal A For the terminal block wiring use a wire with a ring terminal socket only Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during CAUTION wiring work When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections If the outdoor unit is more than 4 meters 24 gt or 5 meters 18K away from the indoor unit you must extend the cable The maximum length of the cable is 15 K 189K 20 24K meters English 42 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 42 KY 2 17 2015 2 56 55 PM Connecting the assembly cable 1 Extend the assembly cable if necessary Do not connect two or more different cables to extend the length caution lt may cause fire 2 Open the cover panel 3 Remove the screw securin
65. r operates in Defrost mode automatically In Defrost mode indoor fan stops and warm air does not come out ARKHJQHH If the doors or windows are open it may cause bad cooling heating ARIA performance Close the doors and windows Check if the air conditioner has just been turned on after stopping cooling or heating arxx Jo gt operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling heating arxa performance may decrease Air flow adjustment is not working Check if you have selected good sleep mode In this mode you cannot adjust the air flow direction If the good sleep mode is operating in Heat mode you can adjust the air flow direction ARKKJOAK MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 31 English 31 SHIHLO 90 2 17 2015 2 56 36 PM Troubleshooting PROBLEM SOLUTION Fan speed e Check if you have selected Auto Dry Fast good sleep mode In adjustment is not these mode fan speed is set to Auto and you cannot adjust the fan working speed Remote controlleris Check if your batteries are depleted not working Make sure nothing is blocking your remote controller sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric wave
66. re it is exposed to the salt in the air please contact your nearest service center Do not touch the circuit breaker with wet hands B This may result in electric shock Do not turn the air conditioner off with the circuit breaker while it is operating gt Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt Ifa child places a bag over its head it may result in suffocation English 6 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 6 K 2 17 2015 2 55 21 PM Donotinsert your fingers or foreign substances into the outlet when the air conditioner is operating gt Take special care that children do not injure themselves by inserting their fingers into the product Do not touch the air flow blade with your hands or fingers during the heating operation B This may result in electric shock or burns Do not insert your fingers or foreign substances into the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not strike or pull the air conditioner with excessive force B This may result in fire injury or problems with the product NOIlWuVdddd LO FOR USING A WARNING Q Donot p
67. rough Smart install function installer can check if the installation was done properly gt If the installation was not done properly error indicator will turn on the indoor unit display Therefore user will know if the installation was done properly or not English 10 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 10 KY 2 17 2015 2 55 24 PM Technical Specifications MODEL AR18JRSDBWK MG AR18J0SDBWK MG CLIMATES CLASS TI T3 T T3 COOLING 18000 Btu h 15500 Btu h 18000 Btu h 15500 Btu h CAPACITY o HEATING H1 5580W RATED VOLTAGE amp FREQUENCY 230V 60 Hz KO m COOLING 68A 82A 69A 83A y RATED CURRENT HEATING H1 69A gt COOLING 1540W 1850W 1560W 1870W o RATED POWER INPUT HEATING H1 a 1550W EER COP COOLING 11 70 840 11 55 8 30 Btu hr Watt HEATING H1 3 60 W W TYPE R 410A REFRIGERANT CHARGE 930 g 32 80 oz 1330 g 4691 02 ANNUAL ENERGY CONSUMPTION 4158 kwh yr 4212 kwh yr 27 C a 29 C 27 C 20 C 29 C 20 C INDOOR 19 C s 19 C 19 C 15 C 19 C 15 C TEMPERATURE 35 C 5 46 C 35 C IX 46 C 7C OUTDOOR 24 C 24 C 24 C 6 C 24 C 6 C INDOOR 157 kg 171 kg NETWEIGHT OUTDOOR 478 kg 518 kg INDOOR 1065 x 301 x294 mm 1065 x 301 x294mm DIMENSIONS OF THE UNIT OUTDOOR 880x793 x310 mm 880x793 x310 mm COUNTRY OF ORIGIN THAILAND MOD
68. rt the Air filter back in its original position Clean the Air filter every 2 weeks Cleaning term may differ depending on the usage and environmental conditions note In dusty area clean it once a week Ifthe Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it ina well ventilated area English 28 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 28 KY 2 17 2015 2 56 35 PM Cleaning the air conditioner I Reassembling the Air filter 1 Putthe filter on the main body and insert the hooks which are in the top of the Air filter into the main body D D Air filter D SHIHLO 90 2 Theres one hook in both side of the filter press the surface of the Air filter softly and get the hooks into the main body 3 Press the bottom of the filter lightly to securely fix the main body DOO English 29 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 29 KY 2 17 2015 2 56 35 PM Maintaining the air conditioner If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut off the power supply There may be internal damage if moisture is left in components
69. s Timer function does Check if you press the SET button on the remote controller after not set you have set the time The indicator Press the Power button or disconnect the power plug switch is blinking off the auxiliary power switch continuously If the indicator is still blinking contact the service center Odors permeatein Check if the appliance is running in a smoky area Ventilate the the room during room or operate the air conditioner in Fan mode for 1 2 hours operation We do not use smelly components in the air conditioner Check the Drains have been cleared Regular Maintenance When an indoor unit indicator blinks contact the nearest service center Please ensure the error code is passed onto the service center when booking the service call Error is indicated Noise is generated Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Smoke is generated If may not bea fire but it can be a steam generated by the defrost from the outdoor operation from outdoor heat exchanger during Heat mode in unit winter ARX Jax Water is dropping Water may be generated because of the temperature difference It from the outdoor is normal unit piping connection English 32 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 32 KY 2 17 2015 2 56 36 PM Safety precautions Carefully follow the prec
70. s Preparation Safety PrECAUtOMs ma kar kaka R R karra RRR 4 Checking DEfOE MISC isda tie sad ss APAKAN NAAANINAG GG GP R R Pa ha Technical Specifications Basic function Checking the name f the Pats wisiccsiersiiweasmecanieasistoasdoamaadsisicgncasan dav RR R RRR 12 Gheckingithe remote Controllersc 4 os nuh saiennasensainnoes kna e E EE EE RR Rk 13 BAGUNG aNG a r Wis Oia kkk Adjusting the air flow direction Timer Setting OO OM MINER isinen i NG KANAN GANAN LG GATA saks 18 a 20 Options 7 StepicoDliNG MUNCHION irda eucacgatasa sa tia aaa E NA NAPAANAK NA GANAN PANANDA te PN AA 21 Using AL SALT nsgsleadscejiaehondecandansaaemes sass R R r RR 22 Using the Comfort FUNGHON erroris ernieren nner bl a b i EAEE a taska AEE EEO ve Del 22 Usirigithe Singleiiser functions paga NAAN R RR r 23 Using theVir s Doctor function essesi E inann pa kaha anng KAU hlang Higa R r 24 Settings ENG INENG LANA NADAANAN R kkr 25 Using NE Auto Cleary UNAN ap naba ATA AA paaa valle AGA ap 25 Setting the Beep sound 26 Resetting the Filter clean reminder ics aaa kaa GANONG GURNA GITARA KENANGAN 26 Setting the Display options as ADA skak 26 Others Cleaningtheaitconditioneriaa AA AA AA 27 Maintaining the air conditioner 30 TOULICENDOOND s r AE TANANG BABANGGA DARANGAN AN AA 31 Installation Safety PFECAULIG IS i asaan ANG KN ANAN ENEE ENEN E GNG NON ALPA UA ANNA AKN AGA 33 Choosing itheiinstallationlOcation Ks sis css aa v
71. t will examine itself through trial operation to check if it was installed properly I Easy Installation It s so easy to install You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product Now you won t have to tilt the product to connect the pipe and the wires Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal English 2 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 2 KY 2 17 2015 2 55 08 PM Content
72. te then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking English 13 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 13 KY 2 17 2015 2 55 35 PM I Remote controller display Operation mode indicator Transmit indicator Low battery indicator Set temperature Time for Timer option indicator Fan speed indicator good sleep indicator Vertical Horizontal air swing indicator Options indicator This function is not available in this model Ea Filter Reset Display Settings indicator Heat mode can be selected AR gt JQ2K gt K Series As to ARX JR X Series don t operate the air conditioner when the remote controller is set to Heat mode Make sure that the water does not get to the remote controller caution Quiet function d light Cool function is displayed on the remote controller display but not supported in this model When turning off and turning on the remote controller the Timer Options and Settings set before turning off the remote controller are cancelled However the fan direction does not change Low Battery warning Inserting the batteries When the battery is exhausted TZ will be displayed in the 1 Push the lever as arrow indicates on the rear side of the remote controller display When the icon appears change remote controller and pull up the Kata The remote controller requires two 1 5
73. ter Reset indicator T F Usage time indicator D 2 Auto clean indicator Defrost indicator 4 F Virus Doctor ARKJQ Series indicator Power button Remote controller receiver Timer Auto Clean indicator English 12 MG BETTER ON8OFF A3050 IB8IM DB68 05189A indd 12 KY 2 17 2015 2 55 34 PM Checking the remote controller Point the remote controller towards the remote controller receiver of the indoor unit When you properly press the button on the remote controller you will hear beep sound from the indoor unit and a transmit indicator appears on the remote controller display I Remote controller buttons NOILINNIJISYA ZO Vertical air swing Activate Deactivate vertical air flow blade movement automatically Power 5 Mode Turn on off the air Set one of the 5 operating modes conditioner Temp Fana v Increase Decrease the Adjust the fan speed temperature by 1 C Options Horizontal air swing Select options during operation Activate Deactivate horizontal air flow Timer i ns etting blades movement automatically Select Timer option Settings Select settings SET Set Cancel the selected option or Directional lt gt setting Move through the Timer Options or Settings menu to make a selection In case you wish to cancel the options or settings that you have just set press the Options or Settings button again no
74. tric shock or fire English 5 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 5 KY 2 17 2015 2 55 19 PM Safety precautions FORPOWERSUPPLY A CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker B Failing to do so may result in electric shock or fire FOR USING WARNING ifthe appliance is flooded please contact your nearest service center P Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke cut off the power supply immediately and contact the nearest service center B Failing to do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power line Do not touch the appliance or power line gt Do not use a ventilating fan gt A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may result in problems with the product water leakage electric shock or fire P A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside whe
75. undry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance gt This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands B This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance B As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner B The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product B This may result in burns or injury Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes gt This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time B This may result in harm to humans animals or plants English 8 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 8 KY 2 17 2015 2 55 21 PM This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsi
76. ure the installed direction of the drain hose is correct Inadequate installation may cause condensate water leakage Ifthe drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors DO NOT WALL UP THE DRAIN HOSE CONNECTION Drain hose connection must be easy accessible and serviceable Changing direction of the drain hose Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the right KO 3 Insertthe drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan Screw hole 5 Check for leakage on both side of the drain outlet Pour the water in direction of arrow Direction of the drained water Make sure the indoor unit is in upright position when you pour water to check for leakage Make sure that the water does not overflow onto the electrical part CAUTION English 48 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 48 KY 2 17 2015 2 57 04 PM Installing and connecting the drain hose of the outdoor unit ARX JQX While heating ice may accumulate During the process of defrosting check if condensation draining is adequate For adequate draining do the following 1 Insert the drain plug into the drain hole on the underside of the outdoor unit
77. ximum CAUTION tothe indoor unit at CAUTION It will reduce noise and vibration total pipe outer wall and cut the height bottom part of the insulation about 10 mm to prevent rainwater from getting inside through the insulation L meters maximum total pipe length Pipe Length Pipe Height Model Minimum Maximum Maximum Make at least one round It will help Palen 3a bi reduce noise and vibration HKH 3 20 8 The appearance of the unit may be different from the diagram depending on the model English 35 MG_BETTER_ON amp OFF_A3050_IB amp IM_DB68 05189A indd 35 KY 2 17 2015 2 56 38 PM Choosing the installation location I Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet 4 Air intake Air outlet e Air flow direction Unit mm When the air outlet is opposite When the air outlet is towards the When 3 sides of the outdoor unit the wall wall are blocked by the wall U LLL LN v Iv S D 3 2 4 5 2 5 It TJ hi V KI NB 150 or more 600 or more The upper part of the outdoor unit The upper part of the outdoor When the walls are blocking front and the air outlet is towards the wall unit and the air outlet is opposite and the rear side of the outdoor the wall unit TR p LLLA gt E 2 O 2000 or more 5 5 ik RE a a CI n a V P