Samsung AC071HBHFKH/SA User Manual

image

Contents

1. S Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time This may result in harm to humans animals or plants This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance FOR CLEANING AA warning Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance unplug the air conditioner from the wall socket and wait until the fan stops P Failing to do so may result in electric shock or fire FOR CLEANING A caution Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges To avoid cutting your fingers wear thick cotton gloves when cleaning it Do not clean the inside of the air conditioner by yourself gt For cleaning inside the appliance contact
2. electric shocks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws The air conditioner contains a refrigerant that has to be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely vv vvv v Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines Always disassemble the electric lines before the refrigerant tubes gt Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer gt After completing the installation always carry out a functional test and provide the instructions on how to operate the air conditioner to the user gt Donotuse the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires explosions or injuries gt Our units should be ins
3. button to go to the next page 5 Press the set button to save and complete the option setting 6 Press the amp button to exit to normal mode B Press the button anytime during setup to exit without setting NOTE A e Option code will not be applied if you dont press the CAUTION e D e Setting indoor unit option code is only possible in Master wired remote controller You can only check the indoor unit option code in Slave wired remote controller e Setting indoor unit option code is possible when one indoor unit is connected If more than 2 indoor units are connected you can only check the Master indoor unit option code 40 Setting an indoor unit address and installation option Set the indoor unit address and installation option with remote controller option Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option atthe same time You need to set twice when setting indoor unit address and installation option Setting an indoor unit address 1 Press the set and amp buttons at the same time for more than 3 seconds and then a Main menu will be displayed lt LI 2 Pressthe gt gt Jbutton to select and then press gt J button to enter a Sub menu setting screen 3 Press the AQ button to select d and then press button to enter a Indoor Address setting screen Data bit e The Main RMC Address which i
4. 4 The pipes and electrical cables connecting the indoor unit with the outdoor Indoor unit unit must be fixed to the wall with suitable ducts a All refrigerant connection must be accessible in order to permit W Be sure to overlap caution either unit maintenance or removing it completely h the insulation 5 Select the insulation of the refrigerant pipe Insulate the gas side and liquid side pipe referring to the thickness Must fit tightly against according to the pipe size caunon body without any gap Indoor temperature of 30 C and humidity of 85 is the stan dard condition If installing in a high humidity condition use one grade thicker insulator by referring to the table below If installing in an unfavorable conditions use thicker one Insulator s heat resistance temperature should be more than 120 C 30 Performing leak test amp insulation Insulation Type Heating Cooling Pipe size Standard 30 C 85 High humidity 30 C over 85 Remarks EPDM NBR 06 35 09 52 9t ot 12 7 19 05 6 35 ing ii is nternal temperature is Se 0 higher SCH 120 C 015 88 19 05 When installing insulation in places and conditions below use the same insulation that is used for high humidity conditions lt Geological condition gt High humidity places such as shoreline hot spring near lake or river and ridge when the part of the building is covered by earth and sa
5. Air around 1200 1250 Suspension position Unit mm 24 1200 gt 1300 500 23 7 3 IE FRE r an S Vibe e MR 125 Suction side gt on Name Description Discharge side Liquid pipe connection 09 52 3 8 Gas pipe connection Drain pipe connection 015 88 5 8 OD25 ID20 without drain pump Power supply connection Air discharge flange Air filter Hook AC100 120 140HBHFKH 700 Unit mm 1 1100 11x100 1268 Air outlet duct flange 22 3 2hole 1300 Air around 1350 Suspension position gt Inspection hole 1300 gt 1400 500 eis k SES 3 E Name Suction side o gt Description Liquid pipe connection 09 52 3 8 Gas pipe connection 15 88 5 8 Drain pipe connection OD25 ID20 without drain pump Power supply connection Air discharge flange Air filter Hook Discharge side 25 Indoor unit installation When deciding on the location of the air conditioner with the owner the following restrictions must be taken into account 1 Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit Since the d
6. B Inspection for PBA is applied b Height is less than 0 5m Both A amp B are applied c A amp B are inspection holes a Siess f LATT KS X VGN LA K Pam y ALL a Unit Width W _ A W 100mm B 500mm H SZ N Zeg H ZN N Zeg H ZN N r H ENT SERIE ae eg age eg Se bar KEN 20mm or more 20mm or more l md You must have20mm or more space between the ceiling and the bottom of indoor unit Otherwise the noise from the vibration of indoor unit may bother the user When the ceiling is under construction the hole for check up must be made to take service clean and repair the unit It is possible to install the unit at an height of between 2 2 2 5m from the ground if the unit has a duct with a well defined lenght 300mm or more to avoid fan motor blower contact GI you install the cassette or duct type indoor unit on the ceiling with humidity over 80 you must apply extra 10mm of polyethylene foam or other insulation with similar material on the body of the indoor unit 21 Deciding on where to install the indoor unit I Insulation Guide Back Vv IN Z Front Thickness more than 10mm Indoor Unit Front Back AC052HBHFKH ACO71HBHFKH 850X700X250 850X250 850X250 700x250 700x250 Insulate the front and back side ACO9OHBHFKH 1200x700x250 1200x250 1200x250 700x250 700x250 in proper size at t
7. Flaring the pipes nennen Performing leak test amp insulation Drainpipe and drain hose installation Interface module Installation Optional Connecting the connection Cord em Adjusting air AO E Smart TUNING GE Setting the indoor unit option code Setting an indoor unit address and installation option 41 Troublesho ting uieesimanisieecnseiieiiee 44 Correct Disposal of This Product Waste Electrical amp Electronic Equipment This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal USING PARTS Safety precautions mama Before using your new air conditioner please read this manual thoroughly to ens
8. Sub menu Functions SEG used Default Range 8 Smart Tuning 2 2 Step 1 1 Step 0 No Use 1 1 Step 2 2 Step Press the button anytime during setup to exit without setting According to airflow changed from the smart tuning Air conditioning performance reducing is possible 39 Setting the indoor unit option code In order to set the indoor unit option code use the wired remote controller and follow the directions below Data bit Page SH Option Code P 1234 56 Main Menu Sub menu 1234 56 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 ie BZ B En SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 1 Press the set and buttons at the same time for more than 3 seconds and then a Main menu will be displayed Ar LI j 2 Press the J button to select i and then press J button to enter a Sub menu setting screen r cl d 3 Pressthe gt gt Jbutton to select and then press button to enter a Indoor unit option code setting screen The first digit represents the page number and the remaining five digits are option codes note The option code which is currently setting will flicker 4 Press the J button to set the option code in order Press gt
9. The place where there is a machine that generates electromagnetic waves The air conditioner may not operate normally due to control system The place where there is a danger of existing combustible gas carbon fiber or flammable dust The place where thinner or gasoline is handled Gas may leak and it may cause fire 19 Preparation for installation When deciding on the location of the air conditioner with the owner the following restrictions must be taken into account j General Do NOT install the air conditioner in a location where it will come into contact with the following elements Combustible gases Saline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions first consult your dealer Avoid installing the air conditioner In areas where it is exposed to direct sunlight Close to heat sources In damp areas or locations where it could come into contact with water for example rooms used for laundry In areas where curtains and furniture could affect the supply and discharge of air Without leaving the required minimum space around the unit as shown in the drawing In scarcely ventilated areas On surfaces that are unable to support the weight of the unit without deforming breaking or causing vibrations during the use of the air conditioner In a position that does not enable the condensate drainage pipe to be correctly installed at the
10. U AMY TAD SOSS Cable tie Indoor Power Communication cable Main power cable Cable clamp Indoor Power 3 Phase 4 Wires Communication cable power cable AC 380V 415V 34 j Between Indoor and Outdoor Connection cable Specifications Common in use Indoor Power supply Communication Cable Power Supply Max Min V Indoor Power cable 220 240V 50Hz 10 2 5mm T 3wires 0 75 1 25mm 2wires For connection cable use the grade HO7RN F or HOSRN F materials Screws on terminal block must not be unscrewed with the torque less than 12 kgf cm Since it has the external power supply refer to the outdoor unit installation manual for MAIN POWER When installing the indoor unit in a computer room use the double shielded Tape aluminum polyester braid copper cable of FROHH2R type In case of extending the electric wire please j Terminal Block SPEC Indoor A DO NOT use a round shaped pressing socket WARNING AC POWER M4 SCREW COMMUNICATION M4 SCREW Incomplete wire connections can cause 8 4 9 5 84 95 electric shock or af re bie Kn Re ARR 35 Adjusting air flow j Automatic Air Volume With its BLDC motor you
11. can use smart adjust the indoor unit fan speed depending on the installation condition Ifthe external static pressure is high so that the duct becomes longer or ifthe external static pressure is low so that the duct becomes shorter Using the Automatic Air Volume function the volume of exhaust air has been adjusted to the rated volume flow rate automatically Performing the Automatic Air Volume function Check the air conditioning unit stop SEG Used Press the Power button to stop the air conditioner Main Menu Sub menu 1234 56 Go to Service setting mode with remote controller 1 Press the set and amp buttons at the same time for more than 3 seconds and then a Main menu will be displayed Press the button to select A and then press utton to enter a Sub menu setting screen 2 b 3 Press the AQ button to select d and then press b 4 utton to enter a Automatic Air Volume setting screen Press the oi button to select 1 to enable automatic air volume operation Select mode No 7 2 and set to 1 5 6 Press the gt button to select 3 and then press button to enter input voltage 7 Press the El button to select 1 3 to set voltage 1 220V 2 230V 3 240V 8 Press the button then the air conditioning unit will start the fan operation for Automatic Air Volume adjustment Do not adjust the dampers during fan operat
12. disconnecting the system always disconnect the electric cables before disconnecting the refrigerant pipes Always remember to connect the air conditioner to the grounding system before performing the electric connections CAUTION The indoor unit is powered by the outdoor unit by means of aH07 RN F connection cable or a more power model with insulation in synthetic rubber and jacket in polychloroprene neoprene in accordance with the requirements of standard EN 60335 2 40 1 Remove the screw on the electrical component box and remove the cover plate 2 Route the connection cord through the side of the indoor unit and connect the cable to terminals refer to the figure below 3 Route the other end of the cable to the outdoor unit through the ceiling amp the hole on the wall 4 Reassemble the electrical component box cover carefully tightening the screw l Layout of Control Box A The layout of Control box is different in each model CAUTION AC052 071 090HBHFKH AC100 120 140HBHFKH l Wiring diagram 1 phase 052 071 090 100 120 140 3 phase 100 120 140 Indoor Unit Indoor Unit AN an ER ala ASA SEULS
13. in water overflowing and property damage When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly gt The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage FORPOWERSUPPLY WARNING Q When the circuit breaker is damaged contact your nearest service center ei Do not pull or excessively bend the power line Do not twist or tie the power line Do not hook the power line over a metal object place a heavy object on the power line insert the power line between objects or push the power line into the space behind the appliance Method of attachment of the supply code such that any replacement is intended to be made by the manufacturer its service agent or similar qualified person FORPOWER SUPPLY A CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker Failing to do so may result in electric shock or fire FOR USING A WARNING If the appliance is flooded please contact your nearest service center Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke unplug the power plug immediately and contact your nearest service center Failing to do
14. only permitted connections are those for which the units are designed Gas refrigerant port Drain tea port 28 Cutting Flaring the pipes 1 Make sure that you have the required tools available pipe cutter reamer flaring tool and pipe holder 2 If you wish to shorten the pipes cut it with a pipe cutter taking care to ensure that the cut edge remains at a 90 angle with the side of the pipe Refer to the illustrations below for examples of edges cut correctly and incorrectly 90 Oblique 3 To prevent any gas from leaking out remove all burrs at the cut edge of the pipe using a reamer 4 Slide a flare nut on to the pipe and modify the flare Outer Diameter D Depth A 06 35 mm 1 3mm 09 52 mm 1 8mm 012 70 mm 2 0mm 015 88 mm 2 2mm 019 05 mm 2 2mm 5 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring HAAAY Correct Inclined Damaged Cracked Uneven Surface Thickness 6 Align the pipes and tighten the flare nuts first manually and then with a torque wrench applying the following torque Flare nut Valve cap Pressure port cap Valve needle Pressure port Wrench mm Nem Wrench mm Nem Wrench mm Nem Wrench mm Nem Wrench mm Nem 17 18 23 20 18 16 18 Allen hex 5 9 0 34 22 42 23 20 18 16 18 Allen hex 5 9 0 34 26 55 29 40 18 16 18 Allen hex 5 13 0 34 29 65 29 40 18 16 18 Alle
15. so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power line Do not touch the appliance or power line gt Do not use a ventilating fan Kk A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Safety precautions FOR USING A WARNING ei Do not touch the circuit breaker with wet hands This may result in electric shock Do not strike or pull the air conditioner with excessive force This may result in fire injury or problems with the product Do not place an object near the outdoor unit that allows children to climb onto the machine This may result in children seriously injuring themselves Do not turn the air conditioner off with the circuit breaker while it is operating gt Turning the air conditioner off and then on again with the circuit breaker may cau
16. your nearest service center gt When cleaning the internal filter refer to the descriptions in the Cleaning and maintaining the air conditioner section Failure to do may result in damage electric shock or fire Checking before use l Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use MODE OUTDOOR TEMPERATURE INDOOR TEMPERATURE INDOOR HUMIDITY COOLING 15 C 5 F to 50 C 122 F 18 C 64 F to 32 C 90 F HEATING 20 C 4 F to 24 C 75 F 27 C 81 F to less 80 or less DRYING 15 C 5 F to 50 C 122 F 18 C 64 F to 32 C 90 F The standardized temperature for heating is 7 C 45 F If the outdoor temperature drops to 0 C 32 F or below the note heating capacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C 90 F indoor temperature it does not cool at its full capacity The use of the air conditioner at a relative humidity above the expected one 80 may caon Cause the formation of condensate and the leakage of water drops on the floor l Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description Against cold air The internal fan will be off to against cold air whe
17. 00 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register N DB68 04651A 1
18. C596F 275A64 374020 12 lt Ps14 01B06C 1C5AA2 275A64 374020 14 lt Ps15 01B06C 1C5AC5 275A64 374020 Model AC100HBHFKH Static Pressure mmAq Option code for indoor unit 3 lt P lt 5 01B06C 1C50F9 276470 377045 5 lt P lt 8 01B06C 1C543E 276470 377045 8 lt P lt 11 01B06C 1C5585 276470 377045 11 lt Ps13 01B06C 1C55C8 276470 377045 13 lt Ps15 01B06C 1C55FC 276470 377045 15 lt P lt 17 01B06C 1C592F 276470 377045 17 lt P lt 19 01B06C 1C5A41 276470 377045 19 lt P lt 20 01B06C 1C5A63 276470 377045 Model AC120HBHFKH AC140HBHFKH Static Pressure mmAq Option code for indoor unit 3 lt P lt 6 2 01B06C 1C544E 27788C 376045 01B06C 1C546E 278CA0 375045 6 2 lt P lt 9 01B06C 1C5595 27788C 376045 01B06C 1C55A7 278CA0 375045 9 lt Ps11 01B06C 1C55C8 27788C 376045 01B06C 1C55DA 278CA0 375045 11 lt Ps13 01B06C 1C55FB 27788C 376045 01B06C 1C590D 278CA0 375045 13 lt Ps15 01B06C 1C592E 27788C 376045 01B06C 1C5A30 278CA0 375045 15 lt Ps17 01B06C 1C5A51 27788C 376045 01B06C 1C5A63 278CA0 375045 17 lt Ps19 01B06C 1C5A73 27788C 376045 01B06C 1C5A85 278CA0 375045 19 lt P lt 20 01B06C 1C5A95 27788C 376045 01B06C 1C5AA7 278CA0 375045 H represents E S P External Static Pressure range of factory setting You don t have to adjust the fan speed separately if the exte
19. Features of your new air conditioner Contents j Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest This summer beat the heat with your own air conditioner l Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner l Flexible installation Duct type air conditioner is designed to be slimmer and offers different solutions for any shape room allowing for specific air flow requirements Also the air intake can be set up on either the bottom or rear of the unit so there is more flexibility in installation Z Applicable in the countries with separate collection systems USING PARTS Safety precautions Checking before use Viewing the parts Cleaning and maintaining the air conditioner A Appen attente dee euer INSTALLATION PARTS Safety EE LU E Preparation for installation Deciding on where to install the indoor unit 21 Indoor unit installation Purging thE Unit uses Connecting the refrigerant pipe Cutting
20. arge etc see the outdoor unit installation manual All refrigerant connection must be accessible in order to permit either unit maintenance or removing it completely 27 Connecting the refrigerant pipe There are two refrigerant pipes of different diameters A smaller one for the liquid refrigerant A larger one for the gas refrigerant The inside of copper pipe must be clean amp has no dust 1 Remove the pinch pipe on the pipes and connect the assembly pipes to each pipe tightening the nuts first manually and then with a torque wrench a spanner applying the following torque Refrigerant oil Outer Diameter D Torque Nem E w Torque wrench 06 35 mm 18 Spanner 09 52 mm 42 Fare nut 012 70 mm 55 4 015 88 mm 65 019 05 mm 100 B Ifthe pipe t be shortened refer to page 14 Nore pipes must be shortened refer to pag 2 Must use insulator which is thick enough to cover the refrigerant tube to protect the condensate water on the outside of pipe falling onto the floor and the efficiency of the unit will be better 3 Cut off any excess foam insulation 4 Be sure that there must be no crack or wave on the bended area 5 It would be necessary to double the insulation thickness 10mm or more to prevent condensation even on the insulator when if the installed area is warm and humid 6 Do not use joints or extensions for the pipes that connect the indoor and outdoor unit The
21. ated to the air conditioner Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed P Failing to do so may result in electric shock or fire Safety precautions FORINSTALLATION WARNING Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit falls it may result in injury death or property damage amp This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line Failure to do so may result in electric shock fire an explosion or other problems with the product gt Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes FOR INSTALLATION Ah CAUTION Install your appliance on a level and hard floor that can support its weight Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly P Failing to do so may result
22. ed off e Check if there is a power failure Check your fuse Make sure it is not blown out The temperature Check if you selected Fan mode does not change Press the Mode button on the remote control to select another mode The cool warm air does not come out of the air conditioner D D D D D D D D Check if the set temperature is higher lower than the current temperature Press the Temperature button on the remote control to change the set temperature Press the Temperature button to decrease or increase the temperature Check if the air filter Optional is blocked by dirt Clean the air filter Optional every two weeks Check if the air conditioner has just been turned on If so wait 3 minutes Cool air does not come out to protect the compressor of the outdoor unit Check if the air conditioner is installed in a place with a direct exposure to sunlight Hang curtains on windows to boost cooling efficiency Check if the cover or any obstacle is not near the outdoor unit Check if the refrigerant pipe is too long Check if the air conditioner is only available in Cool mode Check if the remote control is only available for cooling model 15 Appendix PROBLEM SOLUTION The fan speed does Check if you selected Auto or Dry mode not change The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does Check if you press the P
23. end of the installation It is always essential to check the efficiency of the drainage system COOOOO Accessories The following accessories are supplied with the indoor unit The type and quantity may differ depending on the specifications User amp Installation Clamp hose 1 Flexible hose 1 Insulation drain 1 Thermal insulation manual 1 sponge A 1 CR Thermal insulation Thermal insulation Cable tie 8 Rubber 8 sponge B 1 sponge C 1 20 Deciding on where to install the indoor unit l Indoor unit There must be no obstacles near the air inlet and outlet Install the indoor unit on a ceiling that can support its weight Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indoor unit must be installed in this way that they are out of public access Not touchable by the users After connecting a chamber insulate the connection part between the indoor unit and the chamber with t10 or thicker insulation Otherwise there can be air leak or dew from the connection part j Space requirements for installation amp service E Construction Standard for Inspection Hole KA AAA 1 In case the ceiling is tex tile Inspection hole dose not need 2 In case the ceiling is plaster board Inspection hole depends on Inside height of the ceiing a Height is more than 0 5m Only
24. he same time when insulating the suction duct and discharge duct AC100HBHFKH AC120HBHFKH 1300x700x300 1300x300 1300x300 700x300 700x300 AC140HBHFKH Insulate the end of the pipe and some curved area by using separate insulator Insulate the discharge and suction part at the same time when you insulate connection duct 22 Deciding on where to install the indoor unit AC052 071HBHFKH Unit mm S T CD la B C ONDSWVS gt Si s 3 d EH kb 5 a i 2 5 700 7x100 817 Air outlet duct flange 2203 2 hole Inspection hole 850 Air around 900 Suspension position D S 7 E vA y K KE N N 2 N N x H N N NI T p O02 ie d 323 e 7 z He x E Y 125 Suction side CG 213 Discharge side Name Description Liquid pipe connection 06 35 1 4 Gas pipe connection ACO52HBHFKH 912 7 1 2 AC071HBHFKH 815 88 5 8 Drain pipe connection OD25 ID20 without drain pump Power supply connection Air discharge flange Air filter Hook Deciding on where to install the indoor unit ACO90HBHFKH 1100 11x100 1167 Air outlet duct flange 30 93 2 hole
25. iagram is made of paper it may shrink or stretch slightly due to temperature or humidity For this reason before drilling the holes maintain the correct dimensions between the markings Concrete 2 Insert bolt anchors Use existing ceiling supports or construct a suit px insert able support as shown in figure A a 7 ap Hole in anchor 3 Install the suspension bolts depending on the ceiling type hole in plug A Ensure that the ceiling is strong enough to support the weight Suspension bolt M8 field supply of the indoor unit Before hanging the unit test the strength of each attached suspension bolt elf the length of suspension bolt is more than 1 5m it is required to prevent vibration If this is not possible create an opening on the false ceiling in order to be able to use it to perform the required operations on the indoor unit mi Ceiling support A Screw eight nuts to the suspension bolts making space for hanging the indoor unit B You must install all the suspension rods NOTE 5 Hang the indoor unit to the suspension bolts between two nuts Piping must be laid and connected inside the ceiling when caution Suspending the unit If the ceiling is already constructed lay the piping into position for connection to the unit before placing the unit inside the ceiling 6 Screw the nuts to suspend the unit 7 Adjust level of the unit by using measurement plate for all 4 s
26. ides For proper drainage of condensate give a A mm slant to the When the drain hose is installed to the right left or right side of the unit which will be connected with the drain hose as shown in the figure Make a tilt when you wish to install the drain pump too sent When installing the indoor unit make sure it is not tilted toward front or back side CAUTION Drain hose port Model A GLOBALDUCTType 3mm 26 Purging the unit From factory the unit is supplied and set with a pre charge of nitrogen gas insert gas Therefore all insert gas must be purged before connecting the assembly piping Gas refrigerant port Unscrew the pinch pipe at the end of each refrigerant pipe Liquid refrigerant port RESULT All inert gas escapes from the indoor unit To prevent dirt or foreign objects from getting into the pipes during NOTE installation do NOT remove the pinch pipe completely until you are ready to connect the piping Connect the indoor and outdoor units using pipes with flared caution connections not supplied For the lines use insulated unwelded degreased and deoxidized copper pipe Cu DHP type to ISO 1337 or UNI EN 12735 1 suitable for operating pressures of at least 4200kPa and for a burst pressure of at least 20700kPa Copper pipe for hydro sanitary applications is completely unsuitable For sizing and limits height difference line length max bends refrigerant ch
27. in hose Drain hose MES WY Drain hose Indoor unit As shown in the figure tighten steel ring of the drain hose A an Wrap thermal sleeve hose 31 Drainpipe and drain hose installation l Drainpipe Connection Without the drain pump 1 Install horizontal drainpipe with a slope of 1 100 or more and fix it by hanger space of 1 0 1 5m 2 Install U trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit 3 Do not install the drainpipe to upward position It may cause water flow back to the unit 1 1 5m u Horizontal drainpipe Ceiling more than 1 100 slope With the drain pump 1 The drain pipe should be installed within 300mm to 550mm from the flexible hose and then lift down 20mm or more 2 Install horizontal drainpipe with a slope of 1 100 or more and fix it by hanger space of 1 0 1 5m 3 Install the air vent in the horizontal drainpipe to prevent water flow back to the indoor unit You may not need to install it if there were proper slope in NOTE the horizontal drainpipe 4 The flexible hose should not be installed upward position it may cause water flow back to the indoor unit 200mm or more 300mm or less i i or more 300 550mm Horizontal drainpipe Flexible hose Ceiling more than 1 100 slope 32 Drainpi
28. ing Ifan error occurs during the operation one or more LED flickers and the operation is stopped except the LED Ifyou re operate the air conditioner it operates normally at first then detect an error again LED Display on the receiver amp display unit Indicators Concealed Type Abnormal conditions Remarks Green Red Standard Type Power reset 9 x x x x Error of Room sensor in the indoor unit Open Short 5 Q E Error of EVA IN EVA OUT sensor in the indoor unit Open Short Q x Oo x x Error of Fan motor in the indoor unit X x x ON x Error of Outdoor or Terminal Block Thermal Fuse Open x x Q Q Q Clogging of outdoor s service valve 9 X X Oo oO Detection of the float switch x x X ON ON Error of EEPROM or OPTION SETTING 9 9 999l 1 No communication for 2 minutes between indoor units Communication error for more than 2 minutes 2 Indoor unit receiving the 1 Indoor unit error communication error from outdoor unit Display is unrelated 3 Outdoor unit tracking 3 minutes error x x x with operation 4 When sending the communication 2 Outdoor unit error error from the outdoor unit the Display Is unrelated mismatching of the communication num with operation bers and installed numbers after comple tion of tracking Communication error for more than 2 minutes On GQFlickering X Off Ifyou turn off the air conditi
29. ion for Automatic Air Volume adjustment 9 Press a button to escape setting mode During the automatic air volume adjustment Main Menu will be displayed zu Ir I repetitively 10 After 1 to 8 minutes the air conditioning unit stops operating automatically when Automatic Air Volume adjustment has been carried out fan operation icon will be off 11 When the air conditioning unit has stopped check the Mode No 7 1 is 1 for completion of Automatic Air Volume If the Mode No 7 1 is 0 Automatic Air Volume adjustment is fail Then adjust the fan speed by referring the E S P External Static Pressure setting table 36 Main menu Sub menu Functions SEGused Default Range Some 0 OFF Fail or Disable 1 ale Air Volume State 1 0 1 Completion 2 Running Automatic Air Volume 7 2 Automatic Air Volume 1 0 0 Disable Operation 1 Enable Automatic Air Vol Ve utomatic Air Volume 3 Voltage Setting 1 2 2 230V Default 3 240V If the coil is not dry run the unit for 2 hours with fan only to dry the coil NOTE The air filter is properly attached into the air passage on the air suction side of the air conditioning unit Adjust the dampers so that each air inlet and outlet exhusts the designed airflow rate If using booster fans an outdoor air processing unit or ERV via duct do not use Automatic Air Volume function If the duct configurations have been changed automatic air vo
30. is recommended Frost amp De ice When the air conditioner runs in Heat mode due to temperature difference between the unit and the outside air frost will form If this happens The air conditioner stops heating The air conditioner will operate automatically in De ice mode for 10 minutes The steam produced on the outdoor unit in De ice mode is safe No intervention is required after about 10 minutes the air conditioner operates again normally The unit will not operate when it starts to de ice Fan Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up High indoor e If both indoor and outdoor temperatures are high and the air outdoor conditioner is running in Heat mode the outdoor unit s fan and temperatures compressor may stop at times This is normal wait until the air conditioner turns on again Power failure If a power failure occurs during the operation of the air conditioner the operating immediately stops and unit will be off When power returns the air conditioner will run automatically Protection mechanism If the air conditioner has just been turned on after operation stops or being plugged in cool warm air does not come out for 3 minutes to protect the compressor of the outdoor unit 10 Viewing the parts Congratulations on the purchase of the air conditioner We hope you enjoy the features of
31. lace the remote control batteries 1 Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Outdoor unit Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 This check mark requires checking the indoor outdoor unit periodically following to the description to maintain the air conditioner properly B The described operations should be performed more frequently if the area of installation is very dusty NOTE These operations must always be performed by qualified personnel For more caon detailed information see the installation part in the manual 14 Appendix Troubleshooting Refer to the following chart ifthe air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION Theairconditioner Because of the protective mechanism the appliance does not start does not operate operating immediately to keep the unit from overloading immediately after it The air conditioner will start in 3 minutes has been restarted The air conditioner Check that the power plug is properly connected Insert the power does not work at all plug into the wall socket correctly e Check if the circuit breaker is switch
32. lume function perform again The product can be used within the range of rated voltage 220 V 230 V 240 V 5 V If the product needs to be installed in the condition that is out of the rated voltage stated above additional setting with installation option is required 37 Adjusting air flow B S P External Static Pressure setting for phase control motor With its phase control motor you can adjust the indoor unit fan speed depending on the installation condition Ifthe external static pressure is high so that the duct becomes longer or ifthe external static pressure is low so that ACO52HBHFKH ACO71HBHFKH Pressure mmAq Option code for indoor unit Pressure mmAq Option code for indoor unit 3 lt P lt 4 01B06C 1C540A 27343C 376000 3 lt P lt 4 01B06C 1C5590 274750 375005 4 lt P lt 6 01B06C 1C5550 27343C 376000 4 lt P lt 6 01B06C 1C55D5 274750 375005 6 lt P lt 9 01B06C 1C55C8 27343C 376000 6 lt P lt 9 01B06C 1C592C 274750 375005 9 lt Ps12 01B06C 1C593F 27343C 376000 9 lt P lt 12 01B06C 1C5A83 274750 375005 12 lt Ps15 01B06C 1C5A95 27343C 376000 12 lt P lt 15 01B06C 1C5AD9 274750 375005 Model ACO90HBHFKH Static Pressure mmAq Option code for indoor unit 3 lt P lt 5 01B06C 1C549F 275A64 374020 5 lt P lt 8 01B06C 1C55F7 275A64 374020 8 lt P lt 10 01B06C 1C592B 275A64 374020 10 lt Ps12 01B06C 1
33. n hex 5 13 0 34 36 38 40 18 16 18 Allen hex 5 13 0 34 Ifthe pipes require brazing ensure that OFN Oxygen Free Nitrogen is flowing through the system caution Nitrogen blowing pressure range is 0 02 0 05MPa 29 Performing leak test amp insulation l Leak test LEAK TEST WITH NITROGEN before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R410A it s responsable of installer to pressurize the whole system with nitrogen using a cylinder with pressure reducer at a pressure above 40 bar gauge LEAK TEST WITH R410A after opening valves Before opening valves discharge all the nitrogen into the system and create vacuum After opening valves check leaks using a leak detector for refrigerant R410A A Discharge all the nitrogen to create a vacuum and charge the system CAUTION l Insulation Once you have checked that there are no leaks in the system you can insulate the piping and hose 1 Toavoid condensation problems place T13 0 or thicker Acrylonitrile Butadien Rubber separately around each refrigerant pipe GE NBR T13 0 or thicker 2 Wind insulating tape around the pipes and drain hose avoiding to compress 8 Insulation cover pipe the insulation too much Pip Insulation pipe 3 Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit
34. n the heat pump is heating De ice cycle st AN 4 y he internal fan will be off to against cold air when the heat pump is heating Defrost cycle Anti protection of The compressor will be off to protect internal battery when the air conditioner operates internal battery in Cool mode The air conditioner does not start operating immediately to protect the compressor of Protect compressor the outdoor unit after it has been started Ifthe heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may note have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed Checking before use Tips on using air conditioner Here are some tips that you would follow when using your air conditioner TOPIC RECOMMENDATION Cooling If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness e Avoid drastically turning down the temperature Energy is wasted and the room does not cool faster Heating Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperatures are extremely low If you feel the air conditioner insufficiently heats using an additional heating appliance in combination with the air conditioner
35. nd lt Operation purpose condition gt Restaurant ceiling sauna swimming pool etc lt Building construction condition gt The ceiling frequently exposed to moisture and cooling is not covered e g The pipe installed at a corridor of a dormitory and studio or near an exit that opens and closes frequently The place where the pipe is installed is highly humid due to the lack of ventilation system Drainpipe and drain hose installation Care must be taken when installing the drain hose for the indoor unit to ensure that any conden sate water is correctly drained outside The drain hose can be installed to the right of the base pan 1 Installing the drain hose should be the shorter the better In order to discharge condensation water the drain hose should keep tilted Fix the drain hose with Cable Tie so that it will not separate from the machine While using draining pump connect the end with draining pump 2 Insulate and fix the drain hose according to the figure Insert the drain hose to bottom of the outfall of water basin Lock steel ring of the drain hose according to the figure Wind and wrap steel ring and drain hose fully with thermal insulation sponge fix both ends of external layer with ribbon for thermal insulation After being installed drain hose must be insulated fully by heat insulating material To be pro vided at site Steel ring of drain hose Fix with Cable Tie Joint of dra
36. ning water and dry it in a ventilated area For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a ventilated area 3 Insert the Air filter back in its original position The illustration shown above may differ from yours depending on your model NOTE After cleaning the filter press the Filter Reset button on the remote control for 2 seconds to reset the filter schedule Filter sign indicator will be on for cleaning time 13 Cleaning and maintaining the air conditioner Ifthe air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition gt Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components gt Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness j Periodical checks Refer to the following chart to maintain the air conditioner properly Type Description Monthly PE Once a year Clean the air filter Optional 1 J Clean the condensate drain pan 2 Indoor unit Thoroughly clean the heat exchanger 2 k Clean the condensate drain pipe 2 e Rep
37. nufacturer shall not be responsible for damages arising from the use of non compliant units gt The air conditioner is compliant with the requirements of the Low Voltage Directive 72 23 EEC the EMC Directive 89 336 EEC and the Directive on pressurized equipment 97 23 EEC gt The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry gt Donot use the units if damaged If problems occur switch the unit off and disconnect it from the power supply gt In order to prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy gt Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause
38. oner when the LED is flickering the LED is also turned off 44 Wired remote controller Ifan error occurs is displayed on the wired remote controller If you would like to see an error code press the Test button Display Explanation Remark 1g Communication Error between indoor and outdoor unit H 4 Error of Room sensor in the indoor unit Open Short HS d Error of Eva In sensor in the indoor unit Open Short ced Error of Eva Out sensor in the indoor init Open Short ca i r 22 2nd Detection of the float switch 5 u Error of Fan motor in the indoor unit Ha d EEPROM error Ha E EEPROM option setting error on e i 20 Error of Terminal Block s Thermal Fuse Open fe fe fe No communication for 2minutes betwwen indoor Lu units Communication error for more than 2minutes Hd d Clogging of outdoor s service valve En Error of communication down between the indoor unit Four and wired remote controller after 3minutes Error of communication down between the indoor unit RN Ry and wired remote controller after completion of 10 times tracking Wired remote controller error COM1 COM2 Cross installed error a d L3 Cp Error of master wired remote controller and slave wired remote controller setting A I 7 DU QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT AUSTRALIA 1300 362 603 www samsung com Duct Type Series AC HBHFKH 1
39. ontrol does not Operate If so turn off the unit and switch off the circuit breaker Call your nearest contact center The indicators of the digital display flashes e Press the Power button on the remote control to turn the unit off and switch the circuit breaker off Then switch it on again 16 17 INSTALLATION PARTS Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety ofthe equipment Always disconnect the air conditioner from the power supply before servicing it or accessing A WARNING its internal components Verify that installation and testing operations are performed by qualified personnel e Verify that the air conditioner is not installed in an easily accessible area General information gt Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation gt For maximum safety installers should always carefully read the following warnings gt Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred gt This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The ma
40. ower button on the remote control after not set you have set the time Odors permeate in e Check if the appliance is running in a smoky area or if there is a smell the room during entering from outside Operate the air conditioner in Fan mode or operation open the windows to air out the room The air conditioner A bubbling sound may be heard when the refrigerant is circulating makes a bubbling sound D through the compressor Let the air conditioner operate in a selected mode When you press the Power button on the remote control noise may be heard from the drain pump inside the air conditioner Water is dripping D Check ifthe air conditioner has been cooling for an extended period from the air flow oftime with the air flow blades pointed downwards Condensation blades may generate due to the difference in temperature Remote control is Check if your batteries are depleted not working e Make sure batteries are correctly installed Make sure nothing is blocking your remote control sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves The air conditioner Check if you set the wired remote control for group control does not turn on or off with the wired remote control The wired remote e Check if TEST indicator is displayed on the wired remote control c
41. pe and drain hose installation Testing the drainage Prepare a little water about 2 liter 1 Pour water into the base pan in the indoor unit as shown in figure j 2 Confirm that the water flows out through the drain hose Interface module Installation Optional Accessories Interface module MIM B13D Interface module DC power cable Communication cable PCB Case Cable tie Pa Accessories Interface module MIM B14 External Control PCB Case Haness Wire 2P Haness Wire 4P Screw Sl GEES 2 QO 1 Fix the case at with bolts on the side of the control box in the indoor unit See the picture 2 Attach the Interface module PCB to the case in the control box of the indoor unit then connect the power and the communication cable between the Interface module and the indoor unit 3 If you install a Interface module to an indoor unit every outdoor unit which is connected to an indoor unit can be controlled simultaneously 4 Each indoor unit connected to the same centralized controller has its own Interface module Accessories Virus Doctor module MSD EAN1 Refer to the Virus Doctor module MSD EAN1 installation manual for the more information 33 Connecting the connection cord Always remember to connect the refrigerant pipes before performing the electric connections When
42. pliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Devices disconnected from the power supply should be completely disconnected in the condition of overvoltage category A Make sure that you earth the cables Do not connect the earth wire to the gas pipe water pipe lighting rod or telephone wire If earthing is not complete electric shock or fire may occur Install the circuit breaker If the circuit breaker is not installed electric shock or fire may occur Make sure that the condensed water dripping from the drain hose runs out properly and safely Install the power cable and communication cable of the indoor and outdoor unit at least 1m away from the electric appliance Install the indoor unit away from lighting apparatus using the ballast If you use the wireless remote controller reception error may occur due to the ballast of the lighting apparatus Do not install the air conditioner in following places Place where there is mineral oil or arsenic acid Resin parts flame and the accessories may drop or water may leak The capacity of the heat exchanger may reduce or the air conditioner may be out of order The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet The copper pipe or connection pipe may corrode and refrigerant may leak
43. rnal static pressure of the installation place is in When it is out of input the appropriate option code If you input the inappropriate option code error may occur or the air conditioner is out of order The option code must be inputted correctly by the installation specialist or service agent B The AC100 120 140HBHFKH models have E S P External Static Pressure of the maximum 200Pa NOTE 38 Smart tuning I SMART Tuning If the more cooling and heating airflow rate which set up when installing is wanted or if the more Silent operation which sets up when installing is wanted air conditioner is tuned for comfort Indoor unit airflow rate for high mid low mode increases or decreases for 2 2 Steps with wired remocon 1 Press the User Set button gt Main Menu will be displayed and you can press the A V buttons to select No 8 which will set the smart tuning 2 Press the gt button to select airflow step gt Press the AJ V buttons to select airflow step 2 1 0 1 2 tuning During the Smart tuning setting AC Fan Speed icon will be displayed 3 Press the Lal button to complete the smart tuning Main Menu Sub menu SEG Used 1234 56 When the Smart tuning setting complete AC Fan Speed icon will be off 4 Press the gt button to to exit to normal mode Occupancy OA Intake Main menu
44. s currently setting will flicker Note Data bit 1 and 2 present Indoor unit main address checking Data bit 3 and 4 present Indoor unit main address setting outdoor unit reset is needed to set Data bit 5 and 6 present Indoor unit RMC address setting checking 4 Press the J button to set the Indoor unit Main RMC Address 5 Press the set button to save and complete the option setting 6 Press the amp button to exit to normal mode B Press the button anytime during setup to exit without setting NOTE Address will not be applied if you don t press Set button Setting Main RMC Address of an Indoor unit is available only with a master wired remote controller 41 Setting an indoor unit address and installation option Setting an indoor unit installation option In order to check and set the indoor unit installation option code use the wired remote controller and follow the directions below 1 Pressthe and amp buttons at the same time for more than 3 seconds and then a Main menu will be displayed 2 Press the A 3 Pressthe button to select l and then press LJ button to enter a Indoor unit installation option code setting screen LI GZ e button to select i and then press J button to enter a Sub menu setting screen EN The first digit represents the page number and the remaining five digits are installation option NOTE The total option codes are 24 digits You can set si
45. se a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children Ifachild places a bag over its head it may result in suffocation Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating or the front panel is closing gt Take special care that children do not injure themselves by inserting their fingers into the product Do not touch the front panel with your hands or fingers during the heating operation This may result in electric shock or burns Do not insert your fingers or foreign substances into the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people Since this may be dangerous due to a lack of oxygen open a window at least once an hour FOR USING A WARNING If any foreign substance such as water has entered the appliance cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center P Failing to do so may result in electric shock or fire Q Do not attempt to repair disassemble or modify the appliance yourself gt Do not use any fuse such as cooper s
46. talled in compliance with the spaces shown in the installation manual to ensure accessibility from both sides and allow repairs or maintenance operations to be carried out The unit s components should be accessible and easy to disassemble without endangering people and objects For this reason when provisions of the installation manual are not complied with the cost required to access and repair the units in SAFETY CONDITIONS as set out in prevailing regulations with harnesses ladders scaffolding or any other elevation system will NOT be considered part of the warranty and will be charged to the end customer 18 Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual Always verify that electric connections cable entry section of leads protections are com
47. te delay Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 planation PAGE Use of external Setting the output Virus Doctor Buzzer control Number of hours control of external control using filter Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 0 Disuse 0 Thermo on 0 Disuse 0 G seot 2 1000 Hour uzzer 1 ON OFF Indication Control and Details 2 2 OFF 1 Non Control 1 Operation on Use 1 use of 6 2000 Hour buzzer WINDOW 3 ON OFF Control Option SEG19 SEG20 SEG21 SEG22 SEG23 Explanation PAGE control ofa remote Heating setting Away Set OFF 9 controller compensation Timer Indication Details Indication Details Indication Details Indication Details Auto Oor1 Indoor 1 0 Disuse Oor1 Set OFF 30Min RESERVED oo Indication 2 Indoor 2 1 2 C 2 Set OFF and Details 3 60Min Auto 3 Indoor 3 3 Set OFF 120Min 2 SR Auto 4 Indoor 4 4 Set OFF 180Min 5 Press the S button to save and complete the option setting 6 Press the amp button to exit to normal mode E NOTE Press button anytime during setup to exit without setting e Option code will not be applied if you don t press Set button Setting Installation option code is available only with a master wired remote controller Setting Installation option code is available when there is one on one connection between a wired remote controller and an indoor unit Troubleshoot
48. teel wire etc other than the standard fuse Failing to do so may result in electric shock fire problems with the product or injury FOR USING A CAUTION Do not place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage Check that the installation frame of the outdoor unit is not broken at least once a year Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency S Do not stand on top of the appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product This may result in burns or injury Safety precautions FOR USING Ah CAUTION
49. ure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Aw ARNING Ges a unsafe practices that may result in severe personal injury A CAUTION nn Si Has that may result in minor personal injury Follow directions S9 Do NOT attempt Make sure the machine is grounded to prevent electric shock Unplug the power plug from the wall socket Do NOT disassemble FORINSTALLATION WARNING Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line gt Extending the power line may result in electric shock or fire gt Do not use an electric transformer It may result in electric shock or fire Ifthe voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company P Failing to do so may result in electric shock fire explosion problems with the product or injury Install a switch and circuit breaker dedic
50. x digits at a time and it is distinguished by page number 0 1 2 3 4 Press the O OI button to set the installation option code in order Press button to go to the next page SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 0 2 RESERVED Bee Central control RESERVED temperature sensor SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 Drain pump Use of Hot Coil RESERVED RESERVED Master Slave SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 2 External control Pe Virus Doctor Buzzer Number or nouns output using filter SEG19 SEG20 SEG21 SEG22 SEG23 3 Individual control of Heating setting RESERVED Away Set OFF Timer 2 a remote controller compensation 42 Option No O2XXXX 1XXXXX 2XXXXX 3XXXXX Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Use of external Use of central Explanation PAGE MODE temperature control sensor Indication Details Indication Details RESERVED Indication Details Indication Details RESERVED Indication 0 Disuse 0 Disuse and Details 0 2 1 Use 1 Use Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE Use of drain pump Use of Hot Coil Master Slave Indication Details Indication Details Indication Details Indication Details 0 Disuse 0 Disuse 0 slave Indication 1 Use 1 Use RESERVED RESERVED 1 master and Details 1 Use 2 3minu
51. your air conditioner and stay cool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner l GLOBAL DUCT Type Air filter the return air side A Ceiling Air intake Air outlet L Your air conditioner and display may look slightly different from the illustration shown above depending on your NOTE model 11 Cleaning and maintaining the air conditioner GLOBAL DUCT Plastic Type Optional 1 Press both hooks and take the filter downward 2 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a ventilated area 3 Insert the Air filter back in its original position The illustration shown above may differ from yours depending on your model NOTE After cleaning the filter press the Filter Reset button on the remote control for 2 seconds to reset the filter schedule Filter sign indicator will be on for cleaning time 12 GLOBAL DUCT Steel wire Type Optional 1 Pull out the Air filter from the frame 2 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with run