Home
Installation Manual - Smart Solutions in Security
Contents
1. Installation Manual INTEGRATED ACCESS CONTROLERS PROXIMITY CARD READERS KZC 800 U H KZC 800 M KZC 900 U H aa KaDe VERSION 1 0 An Holding sp z 0 0 Pu awska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 www aat pl Integrated Access Controller Installation manual 1 Introduction Logo Indicator Light Logo Indicator Light Touch Keypad Touch Keypad Card Swiping Area Card Swiping Area Door Bell Button 9 W Door Bell Button Front Panel Front Panel KZC 800 U H M KZC 900 U H Integrated access controllers readers The KZC 800 U H M i KZC 900 U H access control units realize the card reading and keypad operation functions lock alarm ring bell exit button and the mag netic contact switch on the door Those units can be use as standalone controller or standard Wiegand reader These models supports 13 56MHz IC Mifare cards KZC 800 M or 125KHz EM HID Prox cards KZC 800 U H i KZC 900 U H It controls 1 door Supports up to 2000 users in total each user have one card and one PIN PIN 1234 as de fault should be change for normal using The access control unit supports 1 master code one manager add card one manager delete card 1 anti duress card and 1 anti duress PIN providing users with easy operation and safe guarantee Main Features e Aluminum alloy case waterproof fully potted confirms to IP65 e Touch panel Built in 125KHz EM HID card and 13 5
2. all cards are forced output Wiegand 27 37 All rights reserved AAT Holding sp z o o 13 Integrated Access Controller Installation manual In this mode the access host works as reader It can be done below settings Adminstrator Setting Red flash 16 8 digits Master code Enter programming mode Factory default 888888 Reader Setting Red Orange 6 8 digits new master code Repeat 6 8 Factory default 888888 Change the master digits new master code code 0 0 15 Factory default setting 0 To set facility code 26 3 Factory default setting 26 To set Wiegand format 4 6 digis key press sends card number Factory default setting transmission format w 0 Nodoorbellfunction Built in door bell ON Factory default 5 setting To set door bell function External door bell ON Built in amp external door bell ON 0 Disab To set logo LED light 1 Enable Factory default setting OFF The device will be in silence except enter the programming mode To set keypad tone ON The device will give the voice when ON or OFF 1 4 press the keys Factory default setting 0 Disable keypad backlight To set keypad 1 Enable keypad backlight Factory backlight default setting Automatic mode Normally it is off sleeping mode but To set keypad wake up with human approach backlight Disable anti tamper alarm Factory default set
3. 1 0 this mode is describe on next pages Wiring diagram Color __ Function Rea riv Supply power input G2724V D0 U oo wegndm Request to Exit Button input Standalone Access Control LARM O O O lt green Pk Red Blok green Reader rea Bk Door Contact Exit Button LOCKB we NC LOCKA COM 2 _ me Tee To 0 1N4004 1N4004 NO GND Lock A connection for NC type Normally Close locked without supply power Lock B connection for NO type Normally Open locked with supply power All rights reserved AAT Holding sp z 0 0 5 Integrated Access Controller Installation manual Installation and Wiring Diagram Principle of Electronic Lock 12V o 12V The relay will close contact to unlock the lock and will re No lease after unlocking COM common relay contact NC normal close normally keep closed to COM NO normal open normally keep opened to COM Wiring of electronic lock Connect COM and GND connect two ends of electronic lock with 12V and NO or NC complete the circuit Type A electronic lock Fail Secure lock Unlock when power on such as Electronic Controlling Lock smart lock etc Type B electronic lock Fail Safe lock Unlock when power off such as Electromagnetic Lock Electronic Bolt Lock etc 1N4004 Diode prevent high voltage to two ends of the electronic lock while t
4. Entry is by Card and PIN together To set Entry is by either card or PIN Factory default open way setting To set door relay time 3 s Factory default To set door relay time 1 998 setting 3 s Note 8 digits card number such as 118 32319 some cards has no mark of the first 3 digits 118 remains 32319 it requires to add card by read card adding cards by input card number is not acceptable 10 digits card number such as 0007765567 some cards has no mark of the first 3 digits 000 7765567 requires to input 10 digits 0007765567 by add 000 before 7765567 2 APIN 1234 is added for a card it can not be used to unlock the lock can be used to change PIN 3 After one card is added you can continue to add other cards or PIN without exiting the mode 1 All rights reserved AAT Holding sp z 10 Integrated Access Controller Installation manual AdvancedApplication Red Flash O range lash TI Orange Functions Read card Read card Read card 8 digits duress PIN Set add card Set delete card To set duress users To set duress PIN Automatic mode Factory default set Zone 1as Auto lock switch Factory default setting 1 User ID number card number card quantity The card number must be consecutive Card quantity is between 1 2000 Administrator open door 1 Remarks To add card user To delete card user To set duress user To set duress PIN Relay setting To set
5. White logo Red logo LED flash Factory default To enter the 6 8 digits Master code 888888 programming mode Enter Master Operation Mode It will return to normal mode if there is no right Master PIN input in 5 seconds After input of right master PIN it will also return to normal mode if there is no valid operation in 30 seconds Press to confirm the input number return to previous menu by press the logo light will indi cate the operation mode Note that to undertake the following programming the master user must be logged in All rights reserved AAT Holding sp z Integrated Access Controller Installation manual 9 1 Basic Operation Basic Operation 6 8 digits new master code hange th Repeat 6 8 digits new Factory default 888888 ee code master code 1 The user ID number is any number among 1 2000 ID read card 1 2000 8 or 10 digits card number 2 Card number must be 8 or 10 digits if the 3 card number is less than 8 or 10 digits Rotate input 0 before the card number Operation or 10 digits 3 User can be added continuously without Toadd exiting programming mode card users 1 2000 User ID number 4 6 digits PIN To add PIN users 8 or 10 digits card number parte card Rotate Operation 1 2000 ID number 0000 Note This is dangerous option so use Delete All users with care Og Entry is by Card only da
6. card tag read or PIN input the relay will op erate for the pre set relay pulse time In Toggle mode every time a valid card tag read or PIN input the relay changes state which will not turn back until read card tag or input PIN again All rights reserved AAT Holding sp z 7 Integrated Access Controller Installation manual 4 6 To change the PIN of a PIN user Or Remark For the users with card and default PIN 1234 must read card to change the PIN for the first time For users without card must get ID number and initial new PIN from the default 4 7 Door Bell Press the door bell button on the access control unit the buzzer will sound ring back tone at the same time the I box s built in door bell or the outer door bell will ring 5 Alarm 5 1 Anti tamper Alarm When the access control unit is disassembled illegally the access control unit s buzzer and the external alarm will operate 5 2 Door status contact When connect with door status contact if the door is opened illegal the access control unit s buzzer and the external alarm will operate 5 3 Anti duress alarm When read duress card input 8 digits duress PIN the corresponding lock will open at the same time the external alarm will operate but the access control unit s buzzer will not operate 5 4 To remove the alarm Read valid card or input master code can remove the alarm If there is no opera tion the alarm will remove automati
7. open door by multi cards To add aseries cards users Exit automatic System Setting Factory default setting 0 Wiegand reader mode Standalone for single door Factory defaul Anti passback for single door Factory default setting 26 4 6 digis key press sends card number Each key press sends 4 bit output data Factory default Each key press sends 8 bit output data 26 37 Close Alarm Alarm time is 0 3 minutes for option Factory default 1 minute To set facility code To set working mode To set Wiegand format To set keypad transmission format To set Alarm Opeional Setting Indicator light ON Factory default os Dsaebebze O o oo Enable buzzer Factory defaut os Disable keypad backight 1 Enablekeypad backlight Factory default C O _ Disable anti tamper alarm Factory default aa Enableantitamperalarm os Noteypadlochoutor alarm Factory default In 10 minutes if there s 10 times 9 invalid card or wrong password the device will lock on for 10 minutes In 10 minutes if there s 10 times invalid card or wrong password the device will alarm All rights reserved AAT Holding sp z o o To set logo LED light Integrated Access Controller Installation manual Remark 1 Every time valid card tag read or PIN input in in Toggle mode the relay changes state which will not turn b
8. 6MHz IC CPU card ISO14443A reader KZC 800 M only Digital backlit key The back light can be set to Normal ON Normal OFF or Auto With door bell function build in or external door bell optional Multi function operating as slave reader single door anti pass back func tion etc suitable for various occasions All rights reserved AAT Holding sp z 2 Integrated Access Controller Installation manual Detail features 2 000 users with card and PIN 3 identification modes card PIN card PIN Read both 125KHz EM amp HID card PIN length 4 8 digits Pulse mode Toggle mode of lock relay Wiegand 26 37 input amp output Can be worked as controller or reader One relay output for door opening inputs for door status detecting and open door by button Card block enrollment Manager cards for adding or deleting card user easily Very low power consumption 35mA Backlight keypad Light and sound of keypad can be set on off Support door bell connection Built in light dependent resistor LDR for anti tamper Built in buzzer Red yellow and green LED display the working status 12 24V DC ee FH HH HH HF HF FT 59 5 SH Technical specifications Wiring Connections Electric lock External alarm Door status NC Exit button NO Bell Dimensions KZC 800 U H M 125 x 83 x 22 mm HxWxD KZC 900 U H 159 x 43 x 22 mm HxWxD All rights reserved AAT Holding sp z 3 Integrated A
9. ack until read card tag or input PIN again 2 The door will open only when read the valid card quantity up to the quantity set It is only for Card Only mode 3 The card number must be consecutive Card quantity is between 1 2000 4 After unlocking enter the normal working state 5 After closed the alarm anti tamper anti duress and door magnetic alarm are invalid 6 Refers to static state normal indication according to operation 7 Enter the administrator password correctly the buzzer alarm in the normal phonation Each key press or read card keypad backlight will light 30 sec delay after the close in close state the first press key is just to start the keyboard light no any function 9 10 times consecutive errors including enter an invalid master code user password or anti duress or invalid card 10 Set Wiegand ouput format option 7 2 gt 26 to 37 bits concern EM Unique card HID Prox output format depends of number of bits programing on card 10 Various Working Modes Application The device has 3 working modes 1 Wiegand Reader 2 Standalone for single door Factory default setting 3 Anti pass back for single door Through Wiegand data lines can make the device and external card reader are connected together to realize of various functions Card number and PIN etc information will store in the device The external reader only read card or as a device for input PIN you can connect with a numbe
10. cally after 1 minute 6 Keypad lockout or alarm To prevent consecutive enter of an invalid master code user password or anti duress or invalid card this function will be activated after 10 times consecutive errors input There are 3 mode available No keypad lockout or alarm keypad locked for 10 minutes alarm for 1 3 minutes 7 To Reset to Factory Default Touch panel access control power off power on the LED will turn in orange af ter 1 second press within 1 second release it until hearing two shot beep then hearing a long beep enter normal mode reset to factory default setting is successfully Remark Reset to factory default the users information is still retained All rights reserved AAT Holding sp z 8 Integrated Access Controller Installation manual 8 Sound and light indication Operation Status Logo Color Buzzer Standby White Press Key Short Ring Read Card Green Long Ring Unlock the lock Green Long Ring Operation Successful Green Long Ring Operation Failed 3 Short Ring PIN Inputting Slow Flash Red Card amp PIN Reading Slow Flash Red Multi Card Reading Slow Flash Red 1 Menu Slow Flash Red 2 Menu Slow Flash Orange Under Setting Orange Manager Card Reading Orange 2 Short Ring Manager Card Exit White Long Ring Alarm Quick Shine in Red Alarm Ring back Tone Ding Dong 9 Master setting Logo LED Light indication Remarks Functions
11. ccess Controller Installation manual Unit installation Put the paper sticker included in box on the wall in correct horizontal and vertical position in the place where controller should be locate Drill 4 holes diameter 6mm rubber bungs the wall for the screws and 1 hole 30 or 22mm for the cable as written on the sticker figure 1 gt Bracket Photosensitive Tamper Window Sound Hole Connect Wire Back Panel Drill Holes For concrete wall drill the hole in 6mm diameter Safe Screw Hole Bottom Panel Fix the Bracket and Install the Access Host Pay attention to the sequence during installation All rights reserved AAT Holding sp z 0 0 Fix the metal product bracket firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the unit to the metal bracket figure 2 Fix 2 pcs safe screws at the bottom of the unit using supplied tools fig 3 Bracket Photosensitive Tamper Window Sound Hole Connect Wire Back Panel Fix Safe Screws AY E Safe Gemas Integrated Access Controller Installation manual 2 Access standalone controller mode In this mode unit works as standalone controller This is factory default mode command 7 1 1 It s possible to connect additional reader for two way control and activate anti passback feature To change unit for Wiegand reader mode please use command 7
12. external reader inside for exiting door they build up a single door anti pass back system access host is the anti pass back master unit Read valid card or input PIN on access host door will open read valid card or input PIN on external reader door will open When input duress PIN Card the door will open at the same time the ex ternal alarm operates When input duress PIN Card on external reader the door will open at the same time the external alarm operates Open type forced Card Only the user PIN is invalid he users can only enter door when read valid card on access host and exit from the inside external reader If without the entering record from access host the users can not exit from the inside reader also the users can t en ter in twice without the first exit record All rights reserved AAT Holding sp z 0 0 15 AY _ AAT Holding sp z o o 6 a PEAN Pu awska 431 St 02 801 Warsaw tel 4822 546 05 46 fax 4822 546 05 01 e mail aat warszawa aat pl www aat pl
13. he contact of relay disconnect Without diode there will be high voltage pulse interfer ence to circuits and the life time of the relay will be greatly reduced 12V o pera Principle of Alarm Connector Oy The field effect tube will be conducted when alarm is acti vated It will be not conducted when alarm is removed Principle of Door Bell Connector 3 Se Each press of door bell button contact of relay in BELL_A and BELL_B will close contact for 200mS then BELL_B release All rights reserved AAT Holding sp z 6 Integrated Access Controller Installation manual 3 Manager Card operation 3 1 Add user card s Read manager add card Read User card Read manager add card Cards can be added continuously 3 2 Delete user card s Read manager delete card Read User card Read manager delete card Cards can be deleted continuously 4 User Operation 4 1 To unlock the lock by one card Read valid card once 4 2 To unlock the lock for card and PIN users Read valid card once Input 4 6 digits PIN Lock will be unlocked 4 3 To unlock the lock for card or PIN users Read valid card once or Input 4 6 digits PIN Lock will be unlocked 4 4 To unlock the lock for multi cards Read 2 10 valid card Lock will be unlocked Time interval can not exceed 5s Precondition Set the door entry by card only and set 2 10 for opening the door by multi cards 4 5 Toggle Mode In normal mode every time a valid
14. rs of readers but function all same External Access Access Host Host Outside Door Outside Door Inside Door Standalone for single door Anti pass back for single door All rights reserved AAT Holding sp z 12 Integrated Access Controller Installation manual 11 Wiegand Reader Mode In this mode unit works as reader 7 1 0 It can be connect to the stand ard controller with Wiegand port To change unit for Access Controller mode please use command 7 1 1 this mode is describe on previous pages Access Control Unit Reader Mode A een Door Bell Common Access Control 11 1 Wiegand reader mode When LED level is low logo light will turn into Green after 30 seconds or LED level rising Logo light will back to normal When BZ level is low the Buzzer will beep after 30 seconds or BZ level rising the Buzzer will back to normal When the access controller worked as reader both card number and keypad transmits in Wiegand format the output data are shown by the Low Level of DO amp D1 cable D0 Low level means 0 green cable D1 Low Level means 1 white cable The Pulse Width of Low level is 40uS Bit period is 2mS The digit of Card number can be set to 26 27Bit should be matched with the controller Factory default is 26Bit Wiegand 26 card reader HID card can out put Wiegand 26 37 automatically other cards are output Wiegand 26 compul sively Wiegand 27 37 card reader
15. ting To set anti tamper alarm 1 Enable anti tamper alarm All rights reserved AAT Holding sp 7 14 Integrated Access Controller Installation manual Keypad transmission can be set in the following 3 models Model 0 The Reader will transmit the PIN data in card number format when it receives the last key press after PIN code Format Decimal card number with 10 digit Facility Code 1st 4th digit PIN Code 5th 10th digit Facility code is any digits between 0 15 PIN code is 4 6 digits Example Facility code 15 PIN code 2999 gt Press 2999 then output format will be 0015002999 PIN code 999999 gt Press 999999 then output format will be 0015999999 Model 1 4 Bit The output data is provided in following format after every key is pressed 1 0001 2 0010 0011 4 0100 5 0101 6 0110 7 0111 8 1000 9 1001 1010 0000 1011 Model 2 8 Bit The output data is transmitted in following format after every key is pressed 1 11100001 2 11010010 3 11000011 4 10110100 5 10100101 6 10010110 7 10000111 8 01111000 9 01101001 01011010 0 11110000 01001011 11 2 Standalone for Single door In this mode the access host uses can open the door by valid card or PIN it supports connecting external card reader for exiting door 11 3 Anti pass back for Single Door In this mode access host install outside is for entering door
Download Pdf Manuals
Related Search
Related Contents
Digital Sound Level Meter Funkey 61 Edition / Pro Bedienungsanleitung 1 - Datacomm Express CM P1 11643-4 EN Microlog Accessories Catalog ミラーキャビネッ ト Brochure - Dynamax Copyright © All rights reserved.
Failed to retrieve file