1. When disarming the system the function is disabled Car finding In order to locate the car in a full parking area press shortly 0 5s the button 2 Five optical and acoustical signals will be provided The signals will be short if no alarm was reported meanwhile long if there was an alarm since the system was armed This function is active with the system armed only NOTE The car finding function is not active during the reserved 5s after the arming command If the button 2 is pressed during the first 5s after arming this command will be interpreteted according to sensors disabling by remote control procedure Panic In case of emergency pressing shortly 0 5s and simultaneously the two buttons of a remote control can trigger the alarm The siren will sound continuously the pager will emit the alarm signal if there is provided a pager which is optional and the flashing lights will flash for three minutes This function is used to discourage a potential burglar and to draw the attention towards the vehicle The function is enabled no matter of the systems state armed disarmed except the first 5s after arming and can be stopped during the thre minutes by pressing shortly any of the buttons NOTE If the both buttons of the remote are pressed simultaneously during the first 5s after arming the silent alarm function will be enabled during respective arming period the siren will be disabled The silent alarm func
2. last door closed The option could be enabled disabled by remote After the last door was closed the alarm may warn that the system will be passive armed Parameter 5 Temporarily disabling the passive arming If this parameter is enabled then passive arming can be temporarily disabled by opening and closing one door for two times within 5s This parameter is enabled by default Parameter 6 Auto door unlock when disarming The system commands door unlocking when disarming only if this parameter is set as being enabled Contrary to that after disarming the user can unlock the doors using the key This parameter is enabled by default Parameter 7 Auto door unlock when turning OFF the engine The system can unlock the doors automatically when turning the engine off This parameter is disabled by default and can be chosen according to the car owner s option Parameter 8 Auto door lock when starting the engine The system can lock the doors automatically after starting the engine if meanwhile no door is opened This parameter is disabled by default It can be chosen according to the car owner s option Parameter 9 Silent alarm If the system is equipped with pager one can activate the silent alarm function In the silent armed mode in case of alarm the system will make the lights flash and the pager beep only without siren sounding Parameter 11 Door contact delay when arming For certain car types the dome light stays on f
3. lights and optionally by pager for 30s 3 When the car receives a weak shock optical acoustical warning for 1s 4 When the car receives repeated weak shocks within 5s or a strong shock alarm by siren flashing lights and optionally by pager for 15s intermittently 2s ON 1s OFF 5 When violating the interior of the car if the supplementary input is set for ultrasonic sensor alarm by siren flashing lights and optionally by pager for 30s 6 When approaching the car if the supplementary input is set for proximity sensor programmable warning see parameter 10 Notes a If the system is armed with silent alarm function no siren the alarm state will be notified by pager and flashing lights or only by pager according to the value of parameter 9 b Any alarm state can be stopped by pressing shortly 0 5s the button 1 or 2 without disarming the system For disarming the system when the alarm is in progress press button 1 twice once to stop the alarm and second time to disarm the system Comrort FUNCTION The Comfort function is available for some newer models of cars At these cars when twisting the key the doors will lock If maintaining the key twisted for more than 5s then the windows will roll up The Comfort function provides when arming a longer trigger 10s on the lock doors output no matter of parameter 1 value Caution Do not run this wire directly to the door lock actuator but to the command
4. new one b By simultaneously pressing bot buttons of a new remote control while in learning mode then the system will learn that remote control It will not be executed the operation of clearing all the remote controls c If the same remote control is learnt twice it will be confirmed second time too but it will not fill a second memory location 1 In the case a remote control was stolen or lost a clearing of all the remote controls at once operation will be effected Then the remained remote controls and the new ones will be learnt 2 In the case all remote control were stolen or lost a new remote control learning operation will be effected Then a clearing of all the remote controls at once operation will be effected followed by a learning operation for the new remote controls User s Manual ALARM SITUATIONS WHEN THE SYSTEM IS ARMED 1 When opening a door the hood or the trunk alarm by siren flashing lights and optionally by pager for 30s If a door is left opened in a burglary attempt the system triggers the alarm siren flashing lights and pager for three times of 30s each After the 3 x 30s alarm sequence the doors input is bypassed and the other functions of the system are still active This is executed even if the alarm is stopped by remote control If subsequently the related door is closed the doors input becomes active again 2 When trying to start the engine with the key alarm by siren flashing
5. when arming and the power is breaked before the fifth second from the arming then when rearming if the door is still open the system enters a door alarm 12 User s Manual PROGRAMMABLE PARAMETERS The alarm system allows a lot of parameter programming listed in the following table The default values of the parameters are written in bold Contact your alarm system installer to change the parameter programming i ssi Parameter description Unlock the doors when turning OFF the disabled e TETI Oe 15 Comfort enabled disabled 5 Passive arming temporary disabling disabled Unlock the doors when disarming disabled Parameter 0 Siren type It is chosen by the installer according to the siren to be used Parameter 1 Central door lock unlock timing It is chosen by the installer according to central door lock unlock system existent on the car Parameter 2 Reverse car warning The car may provide optic and acoustic warnings by short signals when moving backwards This function is enabled by default and can be activated inactivated by remote control Parameter 3 Door open warning If one of the doors remains open more than 15s after the engine is turned ON the system will notify by 6 short chirps and flashes 5 Alcar H51 Parameter 4 Passive Arming This feature which is disabled by default allows the system to be automatically armed 30 seconds after the engine was turned OFF and the
6. Alcar H51 Auto Alarm System Romano Electro Int s a Foe 27 29 Calimachi str 72266 Bucharest SD Tel 40 1 242 20 20 Fax 40 1 242 20 30 E mail sales roel ro Www roel ro User s Manual Doc 50302 16 08 00 Version 1 0 Alcar H51 User s Manual TABLE OF CONTENT Cote lizza 3 LEARNING GLEARING REMOTE CONTROLS pirssin isicha EtaEta iak Eada CAESA TEKE ns caer ENCARNAR EN EREE EAD IEEE 4 PROGRAMMABLE PARAMETERS SERVICE MODE EMERGENCY DISARMING REMOTE CONTROL OPERATING to iii ian laine Arming disarming with confirmation by siren chirps and flashing lights Arming disarming silent uni Remote controlled bypassing the sensors Arming with silent alarm Car finding Panic Signalling the remote controls number Anti carjacking mode Trunk release function Two level Door unlocking when disarming Two steps disarming ELECTRIC WINDOWS CLOSING WHEN ARMING REVERSE CAR MOVING WARNING Door OPENED WARNING AUTOARMING ocase eaen eieae eee a e a a Ee e a E rae a EEES PASSIVE ARMING VVARNING AT PASSIVE ARMING TEMPORARY DISABLE OF PASSIVE ARMING see A REMOTE CONTROLLED DOORS LOCK UNLOCK AND OR WHEN SWITCHING ON OFF THE ENGINE 11 DUA MODE tia o asa 11 ALARM MEMORY INDICATION BYPASSED FAULTED INPUTS INDICATION c i 12 ANTISCANNING ANTIGRABBING ttt ett tkt Antr k AASEN EAA EAEEEEEAEEE
7. EEAASEEEEEASEEEEEAEEEEE EAEE EE EEEE Ennan 12 NON VOLATILE MEMORY FOR SYSTEM STATES tae 12 ALARM SITUATIONS WHEN THE SYSTEM IS ARMED c iii 13 ComrorT FUNCTION DOOR CONTACTS DELAY WHEN ARMING 15 Alcar H51 14 User s Manual GENERAL FEATURES Alcar H51 is a hopping code remote controlled car alarm system This facility offers a stronger protection than the fixed code systems since the remote control is changing the code at each button pressing The alarm system operating is done by two remote controls trinket type Remote controls range is about 30m If decreasing of light intensity of the LED is noticed then the battery should be replaced The remote control is provided with 2 buttons that will be referred to as 1 and 2 if the remote control has 4 buttons then only the first two will be used for operating the car alarm By combining the two buttons the next following functions emerge 1 Arming disarming by remote controls confirmation by siren chirps and flashing Arming disarming by remote controls confirmation by flashing only Passive arming programmable Warning at passive arming Arming with silent alarm no siren programmable Two steps disarming Protection against accidental disarming auto arming Doors protection Trunk and hood protection apart from the door input Pre warning for weak shocks alarm for strong shocks or repeated weak shocks 0 External
8. d confirms by optical acoustic or optical signal Sensors bypass is only available for that respective arming period When disarming the system the bypass is disabled Example If one wishes to bypass the shock sensor only it will proceed as follows 1 During the first 5s after the arming command press button 2 to advance at the shock sensor without bypassing the proximity sensor The system confirms by an optical acoustical signal or just optical if the arming was silent 2 Press button 1 to bypass the shock sensor The system confirms by an optical acoustical signal or just optical if the arming was silent 3 Press button 2 for not bypassing the ultrasonic sensor If the button 2 is pressed the system confirms by an optical acoustical signal or just optical if the arming was silent Arming with silent alarm If the owner dos not want the theft to be warned then the system can be armed with silent alarm the siren is disabled The using of this function is needed when the system has a pager The alarm state will be notified on page and flashing lights only according to the value of parameter 9 The silent alarm function can only be activated within the first 5s after the arming command User s Manual by simultaneously pressing both remote control buttons The function is active during that specific arming period only The function enabling is confirmed by 2 optical acoustic signals or only optical signals for silent arming
9. em warns by optical acoustical signals or just optical if the system was disarmed silent according to the setting of parameter 2 This parameter is enabled by default for optical acoustic notification Also when disarming silent the reverse car warning is optical only Door OPENED WARNING If after the engine is turned on one of the doors remains opened for more than 15s the system will warn by 6 optical acoustical signals or just optical according to the value of parameter 3 This parameter is set by default for optical acoustical warning If the disarming was silent the door opened warning is optically only If a door is opened while riding the system wil emit the same warning signals after 15s Also the same warning signals will be emitted when the hood or the trunk are opened AUTOARMING To assure the protection against accidental disarming of the system if after disarming command within 30s there is no door opened or the engine is not turned on the alarm system will arm automatically This function is permanently active PASSIVE ARMING WARNING AT PASSIVE ARMING TEMPORARY DISABLE OF PASSIVE ARMING If parameter 4 passive arming disabled by default is set enabled the system will arm passive after 30s from turning off the engine and the last door closed After closing the last door the system will notify by an optical acoustical signal default or just optical for silent disarming If the parameter 5 is enabled t
10. es are tested only after delay duration estabilished by parameter 12 If the delay duration is over and the system detects at least one opened door it will warn by three optical acoustical signals and it will bypass the respective input during arming 6 If afterwards all the doors are closed the respective input becomes active again after sensors stabilization delay 20s after arming Arming disarming silent When no acoustical confirmation is needed press the button 1 for about 2s instead of the short press described before 0 5s All the signals will become silent meaning that the optical confirma tion only will remain active for respective arming disarming period warning for reverse car moving for door open for arming with position lights turned ON for silent siren for sensors bypassing by remote control for doors hood and trunck bypassing for faulted sensors disabling when arming Remote controlled bypassing the sensors Remote controlled bypassing the sensors can only be made during the first 5s after the arming command The bypass order is proximity sensor gt shock sensor gt ultrasonic sensor If the button 1 of the remote control is pressed the system bypasses respective sensor confirms by an optical acoustic or optical signal depending on arming mode and advances to the next sensor If the button 2 of the remote control is pressed the system does t bypass the sensor but it advances to the next sensor an
11. gine 4 blinks door contacts 5 blinks hood trunk contacts After starting the engine the alarm memory will be reset and the LED will turn off BYPASSED FAULTED INPUTS INDICATION If when arming the system has bypassed any input doors hood sensors within 20s after arming then whn disarming after opening any door the hood or trunk the system will indicate by the state LED the type of input as follows 1 blink shock sensor 2 blinks ultrasonic sensor 3 blinks contact key attempt to start the engine 4 blinks door contacts 5 blinks hood trunk contacts After starting the engine the faulted inputs memory will be reset and the LED will turn off The alarm memory is prioritary towards the faulty sensors indication So the LED will indicate the faulty inputs bypassed only if there was no alarm ANTISCANNING ANTIGRABBING ALCAR 51 is protected for scanning and grabbing NON VOLATILE MEMORY FOR SYSTEM STATES When the system is powered again after the power was OFF it enters the state which was previously armed disarmed service anti carjacking If the system was in the arming mode when the power was OFF then at the power restoring the sensors state and the event memory will be restored and the system will tripp a panic alarm Note There is a certain situation namely if parameter 11 Door contacts delay when arming is enabled parameter 12 Door contacts delay duration is 5s a door is opened
12. he passive arming can temporary disable by opening and closing twice a door within 5s The passive arming is useful since it prevents forgetting the car disarmed The passive arming is made without locking doors REMOTE CONTROLLED DOORS LOCK UNLOCK AND OR WHEN SWITCHING ON OFF THE ENGINE If the car is provided with central door lock the system will lock the doors when arming and unlock the doors when disarming according to the value of parameter 6 Also the system can unlock the doors when turning the engine off see parameter 7 or lock the doors when turning the engine on see parameter 8 DUAL MODE This referrs to the possibility of triggering the alarm by the ultrasonic sensor only if within 15s are activated at least tvo sensor types ultrasonic proximity or ultrasonic shock That means that if parameter 14 Dual mode is enabled the alarm triggering by the ultrasonic sensor can only be done if the interior detection was preceded or succeeded within 15s by another sensor triggering shock or proximity 11 Alcar H51 Note The car owner should have another remote control apart from the keys To trigger anti carjacking procedure presslong about 2s button 2 when the engine is turned on The system will enter the procedure and will confirm by flashing lights for 2s After the confirmation the alarm passes the following states 1 During first 14s the alarm does not respond to any remote control command 2 In the f
13. n the system is powered up again it will enter anti carjacking state Trunk release function If an interface module RB 04 is connected for trunk release it will be actionated pressing long for about 2s button 2 of the remote control The function is active only when the system is disarmed and the engine turned off Two level Door unlocking when disarming For two level door unlocking when disarming the system should be provided with the diode D19 on board This way the parameter 6 unlocking doors when disarming should be inactivated In this configuration the system doesn t unlock the doors when disarming while pressing the button 1 For unlocking the doors by remote the button 2 must be pressed more than 2 seconds Once this option enabled the trunk release function is not anymore available Two steps disarming Any alarm state can be stoped pressing the button 1 or 2 for short time aprox 2s without the system to be disarmed For system disarming when the alarm is triggered the button 1 should be pressed twice once for alarm stoping and seconnd for disarming 10 User s Manual SERVICE MODE EMERGENCY DISARMING Within certain situations such as leaving the car to a car service it is recommended to disable the alarm system In this cases the system should be switched to service mode 1 Disarm the system 2 gt Switch the contact key to ON position 3 carne elio elio Press the push button 3 times wi
14. nally LEARNING CLEARING REMOTE CONTROLS The central unit already knows the two remote controls provided with the basic kit Up to four remote controls can be learnt by the central unit In order to learn or clear from memory remote controls one should do the following 1 Disarm the system OFF OFF S 2 I amp Switch the engine contact key twice such as the key switches subsequently ON ON between ON OFF ON OFF 3 grup grup ele Press the push button three times within 15s A success ful enter in learn clear mode will be confirmed by two optical and acoustical signals 4 For learning press one of the remote control s buttons within 15s after pressing the push button a successful learning will be confirmed by an optical acoustical signal 5 To clear all the remote controls from the central unit memory press simultaneously both remote control buttons of a known remote control The clearing of all remote controls at once will be confirmed by three optical acoustical signals 6 To leave the learn mode switch the contact key to ON position Also leaving the learn ON mode will automatically be made after 15s in which there is no remote control button pressed Notes a The remote controls record in the central unit memory is made cyclically from location 1 to location 4 respecting FIFO principle First In First Out So if the memory is full the oldest remote control will be erased when learning a
15. ollowing 16s one can leave the anti carjacking following the exit procedure 3 In the following 30s the alarm emitts short siren sounds and optical signals warning that the engine will turn off One can leave the anti carjacking following the exit procedure 4 After expiry of the 60s the alarm enters the anti carjacking alarm mode in which the engine stops the sirens sounds continuously and the flashing lights are on until the battery is completely discharged One can leave the anti carjacking following the exit procedure To exit anti carjacking mode you must follow the procedure bellow a In any state 2 3 or 4 previously enumerated press the button 2 of remote control The warning or the alarm sounds will be stoped The engine killing will be stoped if the system was in state 4 and the system will emit 1 optical signal for 2s followed by 2 optical acoustic signals b From this point the system waits 30s then it returns to the upper state 3 resuming the warning signals If the button 2 of the remote control is pressed again with contact key in OFF position only the system leaves the anti carjacking mode It emits 1 acoustic signal for 1s followed by 2 optical signals and it enters the disarming mode c If the button 2 is not pressed and the system reaches the state 4 then the exit procedure should be executed again from point a Note After entering the anti carjacking procedure if the alarm power supply is disconnected whe
16. or a certain period of time after closing the last door So door contact duration when arming can or can not be enabled This parameter is disabled by default Parameter 12 Door contact delay duration It represents the time interval within which door contact input is tested since arming Parameter 13 Anti carjacking This function is used if there is the risk of car jacking even in the owner s presence Once the function triggered the car will stop after 2 minutes and enter the alarm mode Parameter 14 Dual mode One should choose this mode since the alarm system was installed on the car and only if an authorized person allows it respectively the alarm system installer This mode refers to the possibility of triggering the alarm by the ultrasonic sensor only if within 15s at least two sensor types ultrasonic perimeter or ultrasonic shock have been activated This mode is useful in case of a complete configuration of the alarm system since it prevents false alarms even though the ultrasonic sensor must be adjusted at the highest sensitivity level Parameter 15 Comfort It is chosen by the installer if the car allows it or according to the car owner s option check Comfort function User s Manual ELECTRIC WINDOWS CLOSING WHEN ARMING When arming the system if there is connected an optional module RB 06 then the windows will close automatically REVERSE CAR MOVING WARNING When moving backwards the syst
17. sensors connection possibility microwave simple or dual and or ultrasonic 11 Car find 12 Panic 13 Reverse car moving warning programmable 14 Warning for door open programmable 15 Warning when approaching the car optional programmable 16 Warning when arming with the lights turned on 17 Engine killing 18 Option for deactivating any sensor by remote control 19 Defective sensors bypassing when arming 20 Separate power supply for each sensor input 21 Low consumption disconnecting the bypassed sensors power supply 22 Remote alarm notify optionally by pager 23 Non volatile memory for system parameters and remote controls 24 System state keeping when disconnecting and reconnecting the power supply 25 Learning clearing remote controls procedure 26 System parameters programming procedure 27 Learnt remote controls number notification 0 AN DA FWN 28 Anti car jacking procedure programmable 29 Anti scanning Anti grabbing 30 Service mode Emergency disarming by valet switch 31 Central door lock module incorporated Alcar H51 32 Remote controlled doors lock unlock and or when switching ON OFF the engine optionally programmable 33 Electric windows closing when arming the system optionally 34 Trunk release by remote control optionally 35 Events Log on the state LED alarm memory indications 36 Bypassed defective sensors indicated on the state LED 37 Back up battery siren optio
18. thin 15s A successful enter to service mode will be confirmed by three short optical acoustical signals orrfN 4 lt Now the contact key can be taken off and the system will remain in service mode The central unit keeps this state even when the power is removed and does not respond to the remote controls buttons press To leave the service mode repeat the upper steps 2 3 and 4 After taking off the contact key the alarm is functional Emergency disarming is necessary in the limit situation when both remote controls have been lost and the alarm system should be disarmed Repeat the upper steps 2 3 and 4 When opening the door the system will trigger the siren until reaching the step 3 After step 4 the system enters the service mode The system disarming is only made after leaving the service mode when new remote controls could be learnt REMOTE CONTROL OPERATING Most of the alarm system functions are operated by means of the two remote controls The range of the remote controls is about 30m The remote control is provided to 2 buttons which will be referred as 1 and 2 The remote control is also provided with a LED that turns on when pressing any of the buttons If one note decreasing of the light intensity of the LED then the battery should be replaced Combining the two buttons it results a lot of functions that will be explained in the followings Arming disarming with confirmation by siren chirps and flashing lights S
19. tion enabling will be confirmed by 2 optical acoustic signals or optical signals depending on arming mode Signalling the remote controls number The hopping code remote controls of ALCAR 51 are learnt by the central unit through the procedure described in chapter 5 1 Learning clearing remote controls The remote controls number recorded in central unit s memory up to 4 can be notified by a simple short press of button 2 while in disarmed mode The system answers by a number of optical acoustical Signals or optical only if the system was disarmed silent equal to the remote controls number Note 1 While disarmed when the engine is turned off pressing long more than 2s the button 2 will activate the trunk release output 2 While disarmed when the engine is turned on if parameter 13 anti car jacking is enabled by pressing long more than 2s the button 2 will enter the anti car jacking mode Anti carjacking mode The function is necessary in the case when the burglar threats the owner and takes the car in its presence with the key in contact Once the function is triggered the car will stop after 1min and will enter the anti carjacking alarm mode
20. wires existing on the car For details please call the manufacturer Door CONTACTS DELAY WHEN ARMING This function is only used for the cars which maintain ON the dome lamp a certain time after the last door is closed In this case the parameter 11 Door contacts delay when arming will be programmed actively Then the state of the door pin switches is only tested after the delay time estabilished by parameter 12 If after delay time the alarm system detects at least a door opened it notifies by 3 opto acoustic signals and bypasses the respective input If afterwards all the doors will be closed the respective input becomes actively again The signal for the door inputs will be taken from the terminal of the dome lamp 13 Alcar H51 It is strongly recommended to use dual mode only when the system is provided with all sensors type shock ultrasonic and proximity This mode is useful under these circumstances because it prevents false alarms Enabling disabling this mode is made by enabling disabling parameter 14 It is not recommended to use the dual mode if the system is not provided with proximity sensor ALARM MEMORY INDICATION If while armed at least an alarm was recorded after disarming and opening the door the system will indicate by the state LED the type of the sensor that triggered the alarm as follows 1 blink shock sensor 2 blinks ultrasonic sensor 3 blinks contact key attempt to start the en
21. ystem arming disarming is simply made by shortly pressing about 0 5s button 1 The system toggles to one state or another according to the current state The arming confirmation is made both optically and acoustically by one signal and the disarming confirmation will be made by two optical acoustical signals on flashing lights and siren When arming 1 If the system detects the hood the trunk or a door opened it warns by three optical acoustical signals and bypasses the respective inputs during arming If afterwards the respective inputs are restored closing the hood trunk or doors they become active After sensors stabilization delay 20s after arming by opening again any door the hood or the trunk the alarm will be triggered 2 If the system detects the position lights turned on it will warn by a signal similar to the proximity approach warning according to the value of parameter 10 When disarming if the alarm has been triggered while armed four optical acoustical signals will be emitted Alcar H51 Note 1 After arming the first 5s are reserved for supplemental commands such as 2 Manual sensors bypass by remote control the proximity sensor the shock sensor and the ultrasonic sensor 3 Silent alarm enabling the siren is disabled 4 System disarming can only be made after the 5s after arming command 5 If the parameter 11 Door contacts delay when arming is enabled then the doors pin switch