Home

Manual

image

Contents

1. 630MM Distance between the a terminal box without cover and the ground Power switch Installation heights Recommended 890 mm for men 870 mm for women Front panel installation screws Drain tank Air filter handydryers www handy dryers co uk Installation Procedures Use a single phase alternating current 220V 240V power supply not to be used with a power supply exceeding 220V 10 E Use a power cord which is between 2mm and 2 5mm thick Cords other than 2mm 2 5mm single core cords cannot be used A drop in voltage is possible if the power cord exceeds 11 m in length so we recommend using a 2 5mm cord Wire the unit Ideally embed the spur in the installation location and wire the power cord if no spur is used the power cord may be distended and prevent the unit from being 630mm installed firmly against the wall agal E Attach the installation panel to the wall using the 6 installation screws installation screws P a J if the wall is masonry use commercially available metal screw plugs curl plugs etc installation a if the wall is not masonry reinforce it panel S de 10 before installation i e RL les installation _hole details unit mm chuckhole 1 Remove the drain tank 2 Remove the front panel 1 Remove the two screws 2 Remove all the front panel ie chuckholes 3 drain
2. tank f front panel installation screw J front panel unit unit 7 Upper hook power socket The installation screws for the unit will not tighten completely if the hooks at the bottom of the installation panel are not in place Ensure the lower hooks are completely hooked onto the rear of the unit Installation panel Lower hook safety screw 1 Attach the front panel 1 Insert the 3 front Panel chuckholes into the unit 2 Replace the 2 screws that were removed _ unit front panel _ 2 Attach the drain tank 3 Make sure the air filter is all the way in installation screw drain tank www handy dryers co uk handydryers Routine Cleaning Before it gets obviously dirty JN WARNING Before you clean the unit turn off the power switch Clean unit with a soft cloth lf unit gets very dirty clean with a soft cloth dampened with neutral agent then clean with a dry soft cloth Remove the dirt from the sensor This will prevent malfunctions Only use neutral cleaning products Do not use thinners acidic or alkaline toilet cleaners or nylon brush e If chemical cloths used please read their instructions first Disinfectants or alcohol based cleaning agents may damage Note your Gorillo hand dryer Cleaning the air filter Around once a week Draining and Cleaning the drain tank Before it fills up a
3. 0 C or above 40 C Where the unit may come into direct contact with water Where the unit is under direct or strong sunlight Where condensation may form within the unit handydcryers www handy dryers co uk Part Names Power indicator _Self check indicator x Hamp a EUT aa _Hand drying area E i Sensor 1 i craig ys Drain hose aes t Air filter Unit Drain tank Full level indicator handydryers www handy dryers co uk Part Names amp Dimensions Terminal Box location Installation Panel 300 Power Cord Terminal Box location Drain Tank Air Filter Accessories Installation Panel fixed screw 6 4 25 tapping screw O Installation Panel ne d handydryers www handy dryers co uk Precautions before installing Do not install in the following types of location otherwise this may cause malfunction Locations where the temperature can exceed 10 C or 40 C Locations where the unit may come into direct contact with water Locations where the unit is under direct or strong sunlight Locations where there is a lot of condensation Locations where corrosive neutral or reductive gases are present Places lower than 20m or higher than 2000m above sea level Power indicator Self check indicator Power supply Unit installed terminal box _Fixed screws installation panel
4. Gorillo Hand Dryer User Manual ykagorillo E handydryers www handy dryers co uk Air Injection Hand Drying The brand new Gorillo is not only good looking but also highly economical in terms of its use of energy running costs and durability The two high speed airstreams force water from your hands to give you a convenient and hygienic drying service without the need to touch any surfaces This unit is suitable for most public places including restaurants office buildings factories supermarkets hospitals and places of recreation Simple to use Shake off excess water at sink Insert both hands face down fingers apart After a few seconds slowly remove hands and repeat process until dry handydryers www handy dryers co uk Do not open the front panel once installed Do not allow the unit to get excessively wet Do not modify and disassemble the unit unnecessarily Do not allow children to hang from the unit Use a single phase AC 220v 240v 50Hz power supply Use a separate electrical spur Turn off the power switch before inspecting and cleaning the unit Ensure the unit is properly grounded earthed Installation work should be carried out by a qualified electrician Be sure to install a residual current circuit break RCD Always use the unit with the drain tank and air filter attached Do not use in the following places Where the ambient temperature is below 1
5. icators are inserted The unit does not stop blowing Indicator light is flashing Specification light up Is the power switch on Are you putting your hands in all the way Is the sensor blocked by dirt or dust If the power supply problems occur the indicator lights up and is flashing Action Turn the circuit breaker on Turn the power switch on Put hands all the way in Turn the power switch off and then after all the lamps in the display have gone off clean the sensor Turn the power switch off Check all the indicators in the display area have gone off around 40 seconds then turn on the power switch again Injection Speed Voltage Frequency Current Power Size 85 95M S 220V 240V 50Hz 7 5A 1 65kW 330X220X687 mm handyaryers www handy dryers co uk
6. t least once a week Empty the drained water in order to prevent accumulated water from exceeding the full level Drained water left for any period of time will become stagnant and foul smelling Pull the drain tank out towards you This ensures the drain water does not splatter out Remove the air filter Pull the air filter out by the handle Full level 1 Cleaning the air filter Tap lightly using your hand or use a vacuum cleaner 1 Open the cover and empty the water i Pull the cover up with your fingers in the direction of the arrow on top of the cover and then remove the cover completely 2 Wash out the inside of the drain tank 3 Close the water tank cover and Re attach it to the unit as before Ensure the two locators are firmly inserted If itis very dirty wash it off with warm water Air filter 2 Re attach to the unit insert it all the way in until it stops If it is not in place the dirt or dust will enter the unit and shorten its service life CD f you wash the air filter with water Clean drain hole with fresh ane dry it as much as possible before re use ote water using the brush provided ih drain hole handydryers www handy dryers co uk Troubleshooting If the following problems occur please perform checks and fix Problem Check No air blows even if hands Do the display ind

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manually update your device drivers windows manual arts high school manual for courts martial manual definition manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manualidades manual transfer switch manual therapy cpt code manual blood pressure cuff manual transmission cars for sale manual handling manual digital manual autopilot enrollment

Related Contents

KESSEL Grease separator `SE` M NS 2, NS 4, NS 7, NS 10, 15 and  MIIAVISION - Miia Style  speaker system pack sys-a3l sys-a2.1l operating instructions  QUICKSTART CSL24V CSL24VH  取扱説明書 - イージーアップ  028_凍結切片作業装置(51KB、PDF形式)  MーTSUBーSHー 取扱説明書    VDOUBLE 10 Manual do Usuário  EVLCDx Z-Wave Specification Rev H  