Home

User Manual

image

Contents

1. frozen 10 Please set up a waterspout on the floor nearby the softener in case of any leaking accidents z B Fix the drain pipe well above the floor drain Floor Drain 11 DO NOT apply any pressure on the softener avoid exposure to direct sun light and radiation from other heating sources 12 Please select regeneration salt pill as regenerant Pipes of the water softener Inlet pipe Outlet pipe dM Overflow pipe The bypass valve Notice Symbol of knob Z Bypass position Symbol ofhandle Water flow direction Symbol ofhandle Turn the handle in the position of the picture above Then water would be bypassed it won t be softened and flow out directly 9 gE Locking clip a Quick connect i Flowmeter socket lt Handle Symbol of handle je Service position Water flow direction Symbol of A i Symbol ofhandle Turn the handle in the position of the picture above The valve is in service position Water will flow through the softener valve and be softened Controller Operation Instruction Control Panel Up 10 30 00 10 30 00 K Water System Water System In Service In Service Dj gw ESD km Water paur Balance Vol 200m Balance Vol 200m yw Display Screen Down Select Menu Esc Manual 1 Display Screen a At service state the display screen shows the following im
2. quality of supply water and the user s actual water use E Cycle process IN SERV Supply water with suitable pressure and flow rate flows into softener and the cations concerns to water hardness Ca Mg etc in the water will be replaced by Na in regenerants then the softening system supply softened water though its outlet Backwash When the ion exchange resins are out of effect the resin bed needs to be regenerated And before the regeneration of resin bed a backwash step is absolutely necessarily for two main purposes remove the residuals and resin shatters in the resin bed and loose the impacted resin bed for a better regeneration efficiency Brine Under certain concentration and flow rate conditions brine flow through entire resin bed then the saturated resins will resume their softening capacity Rinse Rinse the resin bed to remove the residual regenerant salt in it after Brine step until the water from outlet contains no regenerant rinse could also impact the resin bed for a better softening effect Fill Refill water to brine tank to dissolve salt for the next regeneration PE Brine Tank Refill water and salt meet each other in the brine tank and the salt will dissolve continuously to water through natural convection until the water is saturated by salts Operation This product should be able to put in normal use right after the complete installation and a regeneration test any other operations are not ne
3. this 5 seconds to unlook image System System Maintenance Maintenance E 01 represents error code Error 1 2 Select key a Press this key to enter into menu press Up or Down key to show each parameter value b After entered into menu press this key again to show parameter adjusting image the parameter flickers c After setting the parameter press this key thereisasound ding to confirm setting and to return to set up state 3 ESC key a Press this key when not at the menu state this allow you to finish the current working state and go to the next working state immediately You can control valve manually by pressing this key directly b Press this key when in the menu state to go back to the set up menu c Press this key when at the setting state the setting parameter is not saved to return to set up 4 Up and Down keys a Enter into the menu press Up or Down to show each parameter value b When setting the parameter press Up or Down continuously to adjust the parameter c Press Up and Down keys together for 5 seconds to unlock 5 Another information a Current time is 24 hour b Flow rate unit m c When lights it represents key locked condition d The time on right top corner it is the current time e When pressing the Up or Down key to adjust parameter a number is changed incrementally per press Alternatively press the key and hold for longer than 1 5
4. 8 L e Set Rchg Day Set max days between recharges Set Rchg Day 30 Day f Set BackWash Set BackWash 02 Min g Set Brine Set Brine 30 Min h Set Refill Set Refill 05 Min i Set FastWash Set FastWash 03 Min Caution The value of 08 is just taken as an example DO NOT change the parameter otherwise the water may not be treated well 11 How to begin a regenerate progress manually At service state press the ESC key and you will hear the motor running The screen shows Motor Running After several seconds it changes a 10 30 00 Water System Back Washing Left 2Min If you want to end up this step press ESC key again And the valve would go to the next working state immediately if not the valve can complete the regenerate progress itself The rest working states of a regenerate progress are below 10 30 00 Water System Brine amp Slow Rinse Down Flow Left 30Min a 10 30 00 Water System Refilling Left 5Min 4 10 30 00 Water System Fast Rinsing Left 3Min At last the valve returns to the service position Troubleshooting Problem Possible Cause _ Solution Controller does not work 1 Transformer is not plugged in 2 Defective power cord 3 Power off 4 Defective transformer 1 Connect to constant power source 2 Replace cord Incorrect Time of Power outage causes inaccurate According to
5. User Manual Automatic Water Softener Read the User Manual carefully before using the product CONTENTS Components 1 Functions amp Features 1 Operation 2 Cautions 3 Controller Operation Instruction 6 Inquiring and Establishment of Each Parameter 9 Troubleshooting 13 Important Notices back cover Components Automatic Control Valve E Noryl plastic approved by FDA E Strong corrosion resistance stainless E Innovative design refined structure Media E High grade Anion Exchange Resin Food Grade FRP Vessel E Polyethene material manufactured for the Food amp Beverage industries Light high pressure resistance stainless Brine Valve E Reasonable structure safe and reliable E High pressure resistance Functions amp Features Automatic Valve Control 24 hours control and monitoring with a timer automatically regenerate the medial bed at the system s set time of regeneration according to the set regeneration frequency or the water hardness and the balance volume Automatically calculate and design more scientific cycle plan according to the
6. ages every 10 seconds cyclically Balance treated water volume such as 2 00m 10 30 00 Water System In Service Water Balance Vol 2 00m Current flow rate such as 1 00m h a 10 30 00 Water System In Service Water Flow Rate 1 00m h Trig time such as 02 00 6 10 30 00 Water System In Service Water Trig Time 02 00 b When system is at other states it displays the following images ES Work State Showing Content Description ai 10 30 00 10 30 00 current time 2Min Back Wash Water System represents the balance time Back Washing Left 2Min of this state unit minute count down 10 30 00 30Min represents the Error Brine amp Slow Water System balance time of this state Ri Brine amp Slow Rinse unit minute count down isd Down Flow Down Flow represents it Left 30Min recharges by down flow 4 10 30 00 2 Water System 5Min represents the balance Brine Refill a time of this states unit Refilling minute count down Left 5Min a 10 30 00 r Water System 3Min represents the balance Fast Rinse 2 time of this state unit Fast Rinsing s minute count down Left 3Min Motor Running f Tee Motor Running g Work state is switching Key Locked When at key locked state Key Locked Press v amp a key for press any key it shows
7. cessary unless power supply is cut off accidentally The soften unit should be installed and prepared by qualified person any other operations are not necessary while keeping power on all the time and remaining enough salt in brine tank The only requirements for installation are three water pipe ports inlet outlet drain and power supply Fill resin tank with water Initial E Set the control into the backwash position then open water supply valve very slowly to approximately the 1 4 open position and let water flow slowly into the resin tank if open too rapidly or too far resin may be lost When all of the air has been purged from the tank water begins to flow steadily from the drain open the main supply valve to the full position E Drain until the drain water is clear E Shut off water supply and let the unit stand for about five minutes to escape all trapped air from the tank Refill brine tank Manually initiate a whole regeneration cycles after resin tank filling see Appendix to fill appropriate water to brine tank E Salt level should be higher than water level at first time There should be enough solid salt at anytime It is recommended to install a bypass system to ensure water supply in any special cases such as softener failure maintenance etc Cautions 1 Without reading and truly understanding the contents of this user manual please DO NOT perform any operations on the control valve 2 Strictly p
8. er L setting menu is wrong 1 Repeat regeneration making certain that the correct salt dosage is set 2 3 Replace O ring 4 Reset the Water Hardness ee 13 Important Notices The controlling components are driven by an electric circuit Some programmed parameters will be lost as a power outage over 48 hours and water softener system will carry out the regeneration process at the incorrect time We strongly recommend that after a power outage users should check the timer Notice buy the soften salt from the dealer to protect the water softener
9. rohibit leaning position when shipping installing and using this product Otherwise it will be damaged inside 3 During regenerate time water from tap will NOT be softened It is NOT recommended to use water during regeneration otherwise a negative effect on the regeneration result will occur 4 Initial a regenerate cycle after being inactivated in a long period of time and then turn on the tap for several minutes before resuming normal use DO NOT disconnect power during service time to keep the timer run normal that controls the regeneration function 5 If the hardness of raw water dramatically changes change the Water Hardness in the User Setting menu 6 Hot water could cause severe damage to the softener system for water boiler and water heater users ensure the total run of the piping between the softener and the boiler is not less than 3 meters it is recommended to install a check valve between the filter and the boiler if unable to meet the required piping length 7 The input water pressure must be between 0 1 to 0 6 Mpa no negative water pressure allowed 8 No chemical allowed at the inlet and outlet connecting sectors No excessive force which can damage the plastic conjunction parts should be applied by any tools Besides the machine spare part connection material doesn t include in scope of manufacture s warranty 9 The required environmental temperature for softener is 33 8 102 2 F Please protect the softener from
10. seconds to scroll through numbers incrementally at the rate of 1 every 0 2 seconds Holding the key longer than three seconds advances the parameter at the rate of 20 per 0 2 seconds for rapid scrolling Inquiring and Establishment of Each Parameter 1 User setting menu When keys are not locked press key to enter into menu Soft Volume Para Set gt Set Clock Set Rchg Time Set Water Hardness a Set Clock menu Set Clock 09 30 b Set Rchg Time set the recharge time Set Rchg Time 02 00 c Set Water Hardness Set Water Hardness 150mg L 10 2 Factory Setting After you turn on the system during it displays the number of the valve type if you press ESC and key at the same time it will display the factory setting state gt Set Mode Softener Set Valve Mode F65 Set Type Volume Set Resin Vol O8L Set Rchg Day 30Days Set BackWash 02Min Set Brine 30Min Set Refill OSMin Set FastWash 03Min Caution The parameters are all set in the factory So DO NOT change them to prevent unknown errors a Set Mode Set Mod 9 Caution DO NOT change O Purifier j the parameter otherwise the Softener valve can not work normally B Set Valve Mode Set Valve Mode O F63 F65 O F68 O F69 Caution DO NOT change O F82 the parameter otherwise the O F79 valve can not work normally c Set Type Set Type O Timer Volume d Set Resin Vol Set Resin Vol 0
11. the User Manual Regeneration timing to reset the timer Leaking Loose connecting cee joints Noisy Air exists in the system Re backwash the system to vent air Milk white water Tair exists in the system Turn on the tap to vent air Unsatisfied water hardness 1 Poor raw water quality 2 Time of regeneration is too long 3 Resin disable 1 Call your dealer 2 Reset time of regeneration 3 Re regeneration or use new resin Softener fails to use salt 4 1 Water pressure is too low 2 Brine line plugged 3 Injector is plugged 4 Internal control leak 1 Line pressure must be at least 15 PSI 2 Clean brine line 3 Clean or replace injector and screen 4 Check piston seals and spacers Brine container overflow Refill time disordered Call your dealer Water hardness remains 1 Fail to regenerate automatically 2 Brine concentration is poor 3 Injector is plugged 1 Check power of controller 2 Keep brine tank full of salt 3 Disassemble the injector and clear it by washing with water Control backwashes at excessively low or high rate 1 Incorrect backwash controller used 2 Foreign matter affecting controller operation 1 Replace with correct size controller 2 Remove controller and ball Flush with water Untreated water leakage during service 1 Improper regeneration 2 Leaking of bypass valve 3 0 ring around riser tube damaged 4 Water Hardess in the us