1. 43 4 6 Check after Installation c cccccccceceeeeeeeeeeeeeeetetee 44 Lo E elec en en enn set ona Nn ee nian eden a ney on tr ne nee 46 1 Safety Precautions A Large power laser is dangerous to human body especially to eyes Do not face the pigtail fiber of the optical transmitter or the end of the fiber cable connector to eyes A Power sockets with too heavy load or damaged cables and connectors may cause electric shock or fire Regularly check related electric cables If any electric cable is damaged on appearance replace the electric cable immediately A When inserting the power connector of the device into an external power socket make sure that the external power socket is close enough to the device for easy operation If the power cable of the device is straightly connected to an external power supply switch off the external power supply before connecting the power cable Hot line operation is prohibited A Do not fix the product on an unstable support Do not use the device when the grounding cable is damaged or no proper grounding cable is used Perform A regular electric inspection If the grounding cable is damaged replace it immediately za 1 Safety Precautions Install the silicon rubber waterproof band into the recess on A the lower cover of the device case to ensure water proofing 2 Product Introduction The following introduces the functions network appli
2. ccccceececeeeeeececeeeeeeeeeeeeeeeeees 15 3 3 1 Interfaces of the Waterproof Shell 15 3 3 2 Interface of the Eguipment wwwwwwwwwwa 16 3 3 3 Introduction to the Pole Components 17 3 3 4 Introduction to the Cabinet Components 18 4 Production Installation mizizi 20 4 1 Installation Preparation cccceeeeeeeeeeeeeeeetteeeeeeeeees 20 4 2 Plane Mounting Mode 0 cccccceeeeeeeeeeeeeeeeeenteeeeeteeees 20 4 3 Pole holding Mounting Mode 21 4 3 1 Installation Flow Chart wwwwwwmwmamama 21 4 3 2 Pole Mounting Mode 22 4 3 3 Securing the Equipment cccccccceeeeeeeeeeees 25 4 3 4 Connecting Wires and Cables 27 4 4 Wall Mounting Mode ccceceeeeeeeeeeeeeeeeeeeeeeneeeeeees 34 4 4 1 Installation Flow Chart ww wwwawamana 34 4 4 2 Wall Mounting Mode wwwwwwwmmwmammamamamwwara 35 4 4 3 Securing the Equipment wwwwwmmmmmmamaa 38 4 4 4 Connecting Wires and Cables 39 4 5 Cabinet Mounting Mode ccccccccceceeeeeeeeeeeeteetetees 39 4 5 1 Installation Flow Chart wwwwwwwwmmmmma 39 4 5 2 Installing the Mounting EATS w wwwwww 40 4 5 3 Cabinet Mounting Mode c ccccccceceeeeeeeeeees 41 4 5 4 Connecting Wires and Cables
3. Quality of the product documentation Is the information organized and presented clearly 1 2 Very HSomewhat Good ONormal Not at all your advice How do you like the language style of the documentation Poor please specify 12 Are any contents in the documentation inconsistent with the product Is the information complete in the documentation Yes No please specify Are the product working principles and the relevant technologies covered in the documentation sufficient for you to get known and use the product Yes No please specify Can you successfully implement a task following the operation steps given in the documentation Yes please give an example No please specify the reason Which parts of the documentation are you satisfied with Which parts of the documentation are you unsatisfied with Why What is your opinion on the Figures in the documentation Beautiful 0 Unbeautiful your advice Practicall Unpractical your advice What is your opinion on the layout of the documentation Beautiful 0 Unbeautiful your advice Thinking of the documentations you have ever read offered by other companies how would you compare our documentation to them Product documentations from other companies Satisfied
4. 1 2 Take out the AN5121 8GR from the packaging box Lay the equipment gently on a stable plane making sure that the protection earth ground cable interface on the front panel of the equipment is well grounded as shown in Figure 4 1 Figure 4 1 Plane Mounting Mode 4 3 Pole holding Mounting Mode 4 3 1 Installation Flow Chart The installation flow for the pole holding mounting mode is shown in Figure 4 2 Install the pole holding component Install the waterproof shell Install the equipment Lay the wires and cables Figure 4 2 The Installation Flow for the Pole holding Mounting Mode 4 3 2 Pole Mounting Mode The following introduces how to secure the waterproof shell on the wire pole Tool Six point sockets Procedure 1 Take out the equipment base and the clamp Figure 4 3 shows the base and Figure 4 4 shows the clamp Figure 4 3 The Base Figure 4 4 The Clamp 2 Secure the equipment base onto the wire pole with the clamp as shown in Figure 4 5 and fasten the clamp with the six point sockets Figure 4 5 Securing the Eguipment Base 3 Hang the waterproof shell on the equipment base as shown in Figure 4 6 1 Find the hooks on the back of the waterproof shell as indicated by 1 of Figure 4 6 and the gourd shaped holes on the equipment base as indicated by 2 of Figure 4 6 2 Align the hooks on the waterproof shell with the gourd shaped holes on t
5. GPON interface Uplink PON interface complying with the ITU T G 984 standard 3 3 3 Introduction to the Pole Components The pole components comprise the equipment base and clamp The clamp is used to secure the equipment base on the wire pole Figure 3 7 shows the equipment base Figure 3 7 The Base Figure 3 8 shows the clamp Figure 3 8 The Clamp 3 3 4 Introduction to the Cabinet Components The cabinet components include the two mounting ears used to secure the eguipmentin the cabinet as shown in Figure 3 9 and Figure 3 10 3 Product Appearance Figure 3 10 The Mounting Ear on the Right Side of the Cabinet 4 Production Installation 4 Production Installation The following introduces the preparations for equipment installation fixing methods cable connections and check after device installation 4 1 Installation Preparation Before installing the AN5121 8GR check whether the following conditions are met The selected position is suitable for installing and using the AN5121 8GR For example check whether the power cables and network cables can be accessed The installation position provides good conditions for grounding of the workbench wall poles and cabinet The workbench wall poles and cabinet are firmly installed and can bear the weight of the equipment and its accessories 4 2 Plane Mounting Mode The operation procedures are described as follows
6. See Figure 4 13 for the positions and sizes of the holes 290mm Figure 4 13 Positions and Sizes of the Holes Install the expansion sleeve in the holes prepared Install the four screws on the bottom of the waterproof shell into the expansion sleeve and fasten the screws to secure the shell as illustrated in Figure 4 14 1 Screw 2 Expansion sleeve Figure 4 14 Securing the Waterproof Shell 4 4 3 Securing the Equipment Secure the AN5121 8GR in the waterproof shell Refer to Securing the Equipment for the operation procedures 4 4 4 Connecting Wires and Cables The following introduces how to connect the wires and cables for the equipment Refer to 4 3 Pole holding Mounting Mode 4 3 4 Connecting Wires and Cables for the operation procedures 4 5 Cabinet Mounting Mode 4 5 1 Installation Flow Chart The installation flow chart for the cabinet mounting mode is shown in Figure 4 15 Install the mounting ears Install the eguipment in the cabinet Lay the wires and cables Figure 4 15 The Installation Flow Chart for the Cabinet Mounting Mode 4 5 2 Installing the Mounting Ears The following introduces how to install the mounting ears on the equipment Tool A cross screwdriver Procedure 1 Take out the mounting ears and screws delivered together with the eguipment as accessories Install the mounting ears on the left and right sides of the equipment respectively as illu
7. please specify Unsatisfied please specify Additional comments about our documentation or suggestions on how we can improve Thank you for your assistance Please fax or send the completed survey to us at the contact information included in the documentation If you have any questions or concerns about this survey please email at edit fiberhome com cn FiberHome Telecommunication Technologies Co Ltd Address No 67 Guanggu Chuangye Street Wuhan Hubei China Zip code 430073 Website www fiberhomegroup com
8. Thank you for reading and using the product documentation provided by FiberHome Please take a moment to complete this survey Your answers will help us to improve the documentation and better suit your needs Your responses will be confidential and given serious consideration The personal information requested is used for no other purposes than to respond to your feedback Name Contact Phone Number E Mail elp us better understand your needs please focus your answers on complete documentation set Documentation Name Code and Version Usage of the product documentation How often do you use the documentation 1 Frequently maintenance Rarely When do you use the doc in starting up a project Never Other please specify umentation in installing the product Cin daily in troubleshooting HOther please specify What is the percentage of the operations on the product for which you can get instruction from the documentation 100 080 050 0 Other please specify Are you satisfied with the promptness with which we update the documentation Satisfied Print edition Unsatisfied your advice Which documentation form do you prefer Electronic edition HOther please specify
9. standard Supports multiple authentication modes including the physical ID authentication the password authentication and the logical SN authentication Supports the downlink data encryption through the AES128 algorithm Basic Ethernet functions gt Supports the statistics about the Ethernet interface performance Supports the Ethernet interface working mode selection The Ethernet interface can work under the 10 100 Mbit s full duplex half duplex status in the auto negotiation or the forced mode Supports the LAN port based rate control function and the MAC address limit function VLAN related functions gt gt gt gt gt Supports the 802 1P and 802 1Q VLAN protocols Supports the VLAN stacking function Supports the VLAN transparent transmission and VLAN translation in the 1 1 N 1 mode Supports VLAN tags carried by the multicast packets Supports the rate limiting function based on VLAN Multicast related functions gt gt Supports the multicast protocols such as the IGMP Snooping and the IGMP V2 V3 Supports the IPv6 multicast protocols such as the MLD Snooping and the MLD V1 V2 QoS and ACL related functions gt Supports the ACL function which means traffic matching according to the ACL rules gt Has powerful QoS capabilities and supports three scheduling modes SP WRR and SP WRR gt Supports queue mapping The system can map to the corresponding priorit
10. 1 8GR and the waterproof shell for it AN5121 8GR Figure 3 1 shows the appearance of the AN5121 8GR The Appearance of the AN5121 8GR Figure 3 1 The equipment have ventilation holes on its top and both sides All the interfaces and power switches are located on the front panel The AN5121 8GR panel is shown in Figure 3 2 Fiber fome gt ANSI29 Figure 3 2 The AN5121 8GR Panel Waterproof Shell The waterproof shell can be used together with the AN5121 8GR Its top internal side is equipped with the waterproof bumper case which can prevent the rain from entering the shell via the gaps The appearance of the waterproof shell is shown in Figure 3 3 1 Lock 2 LOGO can be customized Figure 3 3 Appearance of the Waterproof Shell The internal structure of the waterproof shell is shown in Figure 3 4 N 1 Cable binding ring optional 2 Optical fiber adapter optional 3 Optical splitter optional 4 Fiber splice tray optional 5 Earth ground component 6 Cable fixing component optional optional Figure 3 4 Internal Structure of the Waterproof Shell A Tip The pictures in this manual are for reference only The main components inside the waterproof shell are described in Table 3 1 Table 3 1 The Main Components inside the Waterproof Shell Component Description Quantity Cable binding Used to pind m
11. FiberHome An Expert in Optical Communications User Manual AN5121 8GR PON Optical Network Unit Version A Code MN000001902 Date September 2014 FiberHome Telecommunication Technologies Co Ltd Version Version Description A Initial version YA L FiberHome are trademarks of FiberHome Telecommunication Technologies Co Ltd Hereinafter referred to as FiberHome All brand names and product names used in this document are used for identification purposes only and are trademarks or registered trademarks of their respective holders All rights redserved No part of this document including the electronic version may be reproduced or transmitted in any form or by any means without prior written permission from FiberHome Information in this document is subject to change without notice Contents 1 Safety Precautions eiscsssccscssscccenisesiceseeracicecdssaaseraceveevenceecine 1 2 Product IntrodUCHtiON mmmzma azma ia zania zaa mazazi 3 2 1 Product Overview ccccccecceceeeeeeeteteeeeeeneeeececeeeeeeeeeees 3 2 2 Network Application w wwwwwwemewamamaamamamaiwa 6 2 3 Technical Specificatio NS 7 3 Product Appearance wwswzizwzmamazamaz zama zazaz zama 10 3 1 Appearance wwwwwwwwwwwwwananaanwwawaw uwumi 10 3 2 Indicator LED Description wwwwwwwwmmmmmmamamaa 14 3 3 Interface Description
12. Figure 4 10 4 3 4 3 Connecting the Network Cable The network cable is used to connect the external communication equipment and the AN5121 8GR Tool A cross screwdriver Procedure 1 Loosen the waterproof connectors on the two wiring holes in the middle of the waterproof shell 2 Lead the RJ 45 connector on one end of the network cable into the equipment via the wiring hole on the right side of the waterproof shell as shown in W of Figure 4 11 oooo o 1 Waterproof connector 2 Cable fixing component Figure 4 11 Connecting the Network Cable 3 Loosen the cable fixing component and lead the network cable through the cable fixing component as shown in of Figure 4 11 4 Production Installation 4 Insert the RJ 45 connector of the network cable into the AN5121 8GR s network interface 4 4 Wall Mounting Mode 4 4 1 Installation Flow Chart The installation flow for the wall mounting mode is shown in Figure 4 12 Install the expansion sleeves Install the waterproof shell Install the equipment Lay the wires and cables Figure 4 12 The Installation Flow Chart for the Wall Mounting Mode 4 4 2 Wall Mounting Mode The following introduces how to mount the waterproof shell on the wall 4 Production Installation Tool An electric drill Ahammer Across screwdriver Procedure 1 Take out the waterproof shell 2 Drill four holes on the wall with the electric drill
13. Technical Specifications Continued Table 2 1 Type Item Description MAC address The capacity of the system MAC address table is 16K Layer 2 line rate forwarding All ports support line rate forwarding QoS Supports eight priority queues at most Supports the SP WRR and SP WRR scheduling modes Network side interface GPON interface One GPON interface is available which meets the ITU T G 984 standard User side interface FE interface Eight FE interfaces are available whose type is RJ 45 They support 10 100 Mbit s full duplex half duplex adaptation Network cables are category 5 waterproof cables The interfaces support the reverse PoE function based on the IEEE802 3 AF AT standard Mechanical parameters Waterproof shell size 80mm x 280mm x 340mm height x width x depth Equipment size 44mm x 230mm x 145mm height x width x depth Weight lt 1 5kg Power supply mode Reverse PoE Power over Ethernet Table 2 1 The AN5121 8GR Technical Specifications Continued Type Item Description Power consump tion j SOW parameters Operating 30 C to 60 C temperature Environ Storage ment 55 C to 125 C temperature parameters Environmental humidity 0 to 80 no condensation 3 Product Appearance 3 1 Appearance The following introduces the appearance of the AN512
14. cabinet Connect the optical fiber for the equipment lead the optical fiber from the external into the cabinet and inset the optical fiber plug into the optical fiber interface Connect the network cable for the equipment lead the network cable from the external into the cabinet and insert the network plug into the network interface 4 6 Check after Installation After all cables are connected and related services are requested from the carrier power on and check the AN5121 8GR as follows 1 Observe the PD indicator LED If the PD indicator LED is ON the equipment is normally powered on otherwise check whether the network cable connection is correct Observe the LOS indicator LED If the LOS indicator LED is OFF the optical cable is normally connected otherwise check whether the optical cable is correctly connected Observe the PON indicator LED If the PON indicator LED is ON the equipment is registered successfully otherwise check the ONU authority on the OLT side Observe the link status indicator LED left If the link status indicator LED left is ON or blinks the network cables are normally connected otherwise check whether the network cables are correctly connected 4 Production Installation 5 During the equipment running ensure that it is correctly grounded to avoid failure If any failure occurs contact the local offices of FiberHome FAQ1 When the Ethernet wiring outlet interface is connected t
15. cal interface and the external communication equipment Tool Across screwdriver Fiber connector preparing tool Procedure 1 Loosen the waterproof connector on the wiring hole at the right side of the waterproof shell 2 Lead one end of the optical cable into the waterproof shell via the wiring hole on the right side of the waterproof shell as shown in of Figure 4 9 IN pE I o 1 Figure 4 9 Connecting the Optical Cable Connect the reinforced core of the optical cable to the earth ground component as shown in of Figure 4 9 Add a connector to the optical fiber in the optical cable and connect the optical fiber to the flange as shown in of Figure 4 9 Connect the optical fiber led into the flange with the optical fiber in the optical splitter Coil the optical fiber in the splitter onto the fiber spool when necessary Connect a branch of the optical fiber in the optical adapter to the optical interface of the AN5121 8GR as shown in of Figure 4 9 Insert the optical fiber which has been coiled onto the fiber spool as necessary into the flange in the fiber adapter to 4 Production Installation 10 4 3 connect with the external optical fiber as shown in of Figure 4 9 Lead the external optical fiber out through the first wiring hole on the left side of the waterproof shell as shown in of Figure 4 9 Connect t
16. cations and technical specifications of the AN5121 8GR 2 1 Product Overview The AN5121 8GR is a GPON FTTB type optical network unit with the reverse PoE Power over Ethernet function specially developed for the network access at the outdoor environment the building access of the broadcast TV and telecommunication operators etc It can form a gigabit GPON system with the FiberHome GPON station central office devices Its main features are described as follows Provides one GPON uplink port and eight FE downlink ports Supports the DC 12V power supply or the power supply via the Ethernet using the PSE device compliant with the IEEE802 3 AF AT standard Itcan be used together with the assorted protection case This device features lightning protection water proofing power surge prevention high and low temperature resistance oxidation resistance acid and basic corrosion resistance and high reliability It can be installed and operates under unfavorable outdoor conditions Performs the reverse feed function and supports the power supply provided by the devices under it via the Ethernet physical line Therefore it does not require an external power supply at the installation site which can lower the deployment and maintenance cost i 2 Product Introduction Function The AN5121 8GR supports the following functions Basic PON functions gt Uses the GPON connection in the uplink direction meeting the ITU T G 984
17. er supply status gt Supports the alarm reporting under the RPoE power supply interruption The internal design of the equipment can ensure the stability of the power supply feed Product Model AN5121 8GR with eight FE interfaces 2 2 Network Application The AN5121 8GR is mainly applied in the FTTB FTTV access scenarios It obtains the feed from the user side PSE and provides conventional data transmission services for the subscribers The AN5121 8GR is characterized by its adaptability to multiple outdoor installation scenarios Therefore it can serve as the network access equipment in the field or at public locations For example you can secure it onto a wire pole using the pole holding mounting mode to access public telephones Figure 2 1 shows the network diagram for the common application scenarios of the AN5121 8GR b20V mains suppl oe z z Fa Fd r 7 7 r F 1 Internet A IMS Softswitch R ANM2000 telephone Figure 2 1 The AN5121 8GR Application Network 2 3 Technical Specifications The technical specifications of the AN5121 8GR are listed in Table 2 1 Table 2 1 The AN5121 8GR Technical Specifications Type Item Description Supports the IEEE 802 1Q 802 1P VLANs and VLAN based selective QinQ VLAN One port supports translation of 16 unicast VLANs Supports 4095 VLANs at most Service parameters 2 Product Introduction The AN5121 8GR
18. he equipment base to hang the equipment from the top down 1 Hook 2 Gourd shaped hole Figure 4 6 Hanging the Waterproof Shell 4 3 3 Securing the Eguipment Tool A cross screwdriver Procedure 1 Find the mounting holes at the bottom of the AN5121 8GR and the hooks inside the waterproof shell 2 Install the sheet metal delivered together with the equipment to the bottom of the equipment as illustrated in Figure 4 7 Figure 4 7 Installing the Sheet Metal 3 Align the mounting holes as shown in 1 of Figure 4 8 at the bottom of the AN5121 8GR with the hooks as shown in 2 of Figure 4 8 inside the waterproof shell and hang the equipment on the waterproof shell as illustrated in Figure 4 8 1 Mounting hole 2 Hook Figure 4 8 Securing the Eguipment to the Waterproof Shell 4 3 4 Connecting Wires and Cables The following introduces how to connect the wires and cables for the eguipment Eg 4 Production Installation The wires and cables to be connected for the equipment include The optical cable The earth ground cable The network cable A Tip 1 Before leading the external wires and cables into the waterproof shell you need to loosen the waterproof connector 2 After completing the layout of the wires and cables fasten the waterproof connector and seal the interface 4 3 4 1 Connecting the Optical Cable The optical cable is used to connect the equipment opti
19. he optical fibers led out from the waterproof shell to the optical interfaces of other AN5121 8GR equipment 4 2 Connecting the Earth Ground Cable A Tip The equipment earth ground cable is used to connect the equipment and the external earth ground bar The equipment earth ground cables comprise the external earth ground cable and the internal earth ground cable Tool A cross screwdriver Procedure 1 Loosen the waterproof connector on the wiring hole at the right side of the waterproof shell Lead one end of the external earth ground cable into the equipment via the wiring hole on the right side of the waterproof shell as shown in W of Figure 4 10 1 Waterproof 2 Connector post 3 Earth ground point connector Figure 4 10 Connecting the Earth Ground Cable 3 Secure the external earth ground cable entering the equipment onto the connector post of the earth ground component as shown in of Figure 4 10 4 Connect the other end of the external earth ground cable to the external earth ground bar 5 Secure one end of the internal earth ground cable to the earth ground point of the earth ground component as shown in of Figure 4 10 E 4 Production Installation Connect the other end of the internal earth ground cable to the earth ground hole of the AN5121 8GR and coil the redundant part of the cable onto the fiber spool component as shown in of
20. inking ie logical link has been set up ACT pause Green indicator GEE The logical link has not been LED set up Port The AN5121 8GR is receiving ON receiving the power supply feed PD Renee Green supply feed The AN5121 8GR is not indicator OFF receiving the power supply LED feed Optical ON The Rx optical power of the PON portis too low Los signal status Red indicator ere The Rx optical power of the LED PON port is normal ON The AN5121 8GR is PON status registered PON indicator Green The AN5121 8GR is not LED OFF registered Table 3 2 Description on Indicator LEDs of the AN5121 8GR Continued Silk screen Meaning Color Status Indicator LED Description Name A certain equipment set is ON connected to the LAN port without data transmission Link status 7 A sae A certain equipment set is indicator Orange os Blinking connected to the LAN port LED left gt with data transmission LAN OFF No equipment set is connected to the LAN port Duplex N The port operates in the full status duplex mode Tarn Green indicator pa The port operates in the LED right half duplex mode 3 3 Interface Description 3 3 1 Interfaces of the Waterproof Shell The interfaces on the waterproof shell are shown in Figure 3 5 Figure 3 5 Interfaces on the Waterproof Shell Ja 3 Product Appearance Table 3 3 Interfaces on the Waterproof Shell Serial In
21. notice 1 2 The Warranty Card shall come into force with the seal of dealer Please keep this card properly No reissuance will be provided if you lose it and it becomes invalid if altered In the event of a non man made malfunction during the warranty period FiberHome will repair or replace this product to its original operating condition free of charge Warranty does not cover the following circumstances 1 Damage or malfunction caused by transporting loading and unloading Damage or malfunction caused by man made reasons such as opening or remodel the machine on users own Damage or malfunction caused by unsatisfactory environment Damage or malfunction caused by force majeure incidents such as fire earthquake lightning strike war Damage or malfunction caused by failure to operate and maintain in accordance with the user s manual Damage of external parts such as equipment enclosure power connector in operation The inconsistence of the Warranty Card and the product serial number or the warranty card has been altered We provide paid repair and maintenance service for the products that are beyond the warranty scope The final explanation rights of this warranty description are reserved by FiberHome FiberHome Telecommunication Technologies Co Ltd No 67 Guanggu Chuangye Street Wuhan Hubei China Made in China Toh a single documentation or a Product Documentation Customer Satisfaction Survey
22. o the client side PSE Power Supply Equipment the ONU can not be powered 1 Check whether the power supply for the PSE is well connected and whether the PSE is providing power normally 2 Check whether the network cable meets the requirements concerned 3 Test whether the No 1 and No 2 network cables are 48V ones and whether the No 3 and No 6 network cables are OV ones 4 Check whether the PSE is faulty 5 Check whether the ONU equipment is operating normally FAQ2 All the indicator LEDs are extinguished after the equipment is powered on 1 Check whether the PSE equipment is providing power normally and whether the voltage is stable within the specified range 2 Check whether the network interface on the ONU side is correctly connected FAQ3 The equipment stops running after normal operation for a period of time 1 Check whether the PSE equipment is providing power normally and whether the voltage is stable within the specified range 2 Check whether the network interface on the ONU side is correctly connected FAQ4 The LOS indicator LED is ON 1 Check whether the optical cable is damaged 2 Check whether the optical fiber connector of the optical cable is normally connected to the ONU optical interface 3 The Rx optical power of the ONU is excessively low 4 The optical module of the ONU is aged or damaged 5 The terminal equipment is faulty FAQ5 When the Ethernet wiring outlet port is connected
23. strated in Figure 4 16 2 Installing the Mounting Ears Figure 4 16 t Mounting Mode ine 4 5 3 Cab Prerequisite When the mounting ears are used users can install the AN5121 8GR inside a 19 inch cabinet Tool A cross screwdriver 4 Production Installation Procedure 1 Take out the floating nuts and screws delivered together with the equipment and fix the floating nuts horizontally at proper positions on the cabinet Align the screw holes on the mounting ears and bent angle brackets on both sides of the AN5121 8GR Push the mounting ears and bent angle brackets slowly toward the floating nuts until they touch closely Then insert the screws into the screw holes on the floating nuts and tighten them as shown in Figure 4 17 Take your hands away from the equipment slowly so that the AN5121 8GR is mounted in the cabinet with the supporting of the screws f S Figure 4 17 Installing the Equipment in the Cabinet 4 5 4 Connecting Wires and Cables The following introduces how to connect the wires and cables for the equipment The wires and cables to be connected for the equipment include The earth ground cable The optical fiber The network cable 4 Production Installation Procedure 1 Connect the earth ground cable for the eguipment connect one end of the earth ground cable to the earth ground point of the equipment and the other end to the vertical mounting flange of the
24. terface Description Number Inlet for the optical The optical cable is led into the fiber waterproof shell through this interface 1 Wiring interface for The network cable is led into the the network cable waterproof shell through this interface 2 Outlet for the The optical cable is led out of the optical fiber waterproof shell through this interface 3 3 2 Interface of the Equipment The AN5121 8GR interfaces are all on the front panel as shown in Figure 3 6 a Fiberi Tom AN5121 Figure 3 6 The Equipment Interface 1 Protection earth gound interface 2 DC power interface 3 Power switch 4 Ethernet interface f 5 Console interface 6 GPON interface RPOE interface The description of each interface is shown in Table 3 4 Table 3 4 Interfaces of the Eguipment and Description Interface of the Eguipment Description Protection earth ground interface Is used to connect the protection earth ground cable DE PoS Is used to induct the external 12 V DC power supply interface Power switch The power switch of the AN5121 8GR Ethernet interface RPOE interface Eight FE interfaces used to access the LAN side users and receive the power supply feed of the PSE Console interface Debugging serial port used to debug the AN5121 8GR in the local connection mode
25. to the client side PSE the PSE provides power intermittently 1 Check whether the power supply for the PSE is well connected and whether the PSE is providing power normally 2 Check whether the Ethernet cable meets the requirements concerned 3 Test whether the No 1 2 3 and 6 network cables have stable voltage 4 Check whether the PSE is faulty 5 Check whether the ONU equipment is operating normally 232 FiberHome Product Warranty We appreciate your purchase of FiberHome product FiberHome warrants that the eguipment will be free of defects in materials and workmanship for a period of 12 months from the date of purchase The original dated bill of sale should be retained as proof of purchase and must be presented to FiberHome when the eguipment is to be serviced under the provisions of this warranty Customer Name Address Zip Code Phone Model Number Serial Number Date of Purchase Invoice Number Dealer Name Dealer Address Phone Please keep this card property No reissuance if lost Dealer Seal Warranty Description When you purchase a product offered by FiberHome from an authorized dealer you have a 12 month warranty as standard except for man made causes The warranty period begins on the date of invoice For your lawful rights and interests please
26. ultiple network cables A connecting the AN5121 8GR with the 4 ring optional exterior It is the flange The fibers of the optical Optical fiber cable after being branched can be led into adapter this component first and then led out to the 10 optional exterior via it for the convenience of maintenance Optical splitter Optional used to split the signal from the previous optical cable Users can select this component according to their demand The optional ji f f i splitters are available with two kinds of split ratio 1 4 and 1 8 Optional used to splice and branch optical Fiber splice ps i pi po tray optional fibers Users can select this component according to their demand Earth ground Used to provide the earth ground point for component the earth ground cable and the optical cable 1 optional reinforced core inside the shell Cable fixing component Used to secure the network cable 1 optional 3 Product Appearance 3 2 Indicator LED Description The AN5121 8GR has various indicator LEDs on it Except for the four round indicator LEDs ACT PD PON and LOS the link status and duplex status indicator LEDs are located beside each LAN port The description on each indicator LED is shown in Table 3 2 Table 3 2 Description on Indicator LEDs of the AN5121 8GR Silk screen Meaning Color Status Indicator LED Description Name Working Bl
27. y queue according to the 802 1P priority and the DSCP priority gt Supports the flow rate control based on the flow classification rule and the re marking of priority gt Supports bandwidth rate control based on the ONU and guarantees the services with higher priorities Access control functions gt Supports the DHCP line label function gt Supports the PPPoE function to identify users accurately Equipment management and maintenance functions gt Supports the local WEB network management function The operators can log in via the user LAN1 port to view the information of the AN5121 8GR and modify the logical SN and password of the ONU gt Supports managing the ONU remotely in the Telnet mode and users can view the ONU status information and print the debug information gt Supports configuring the port modes querying the port status monitoring the overall power supply status of the equipment and collecting and reporting the alarm information Security related functions gt Supports limiting the quantity of MAC addresses at a certain port gt Supports the broadcast storm restriction function for the user port and the uplink port ii 2 Product Introduction gt Supports protection against various network attacks including ARP attack ICMP attack DOS attack and BPDU attack RPoE function gt Supports the RPoE function compliant with the IEEE802 3 AT AF standard gt Supports querying the RPoE pow
Download Pdf Manuals
Related Search
Related Contents
Dell Latitude C600 Laptop Keyboard 47NVF Tricity Bendix AW 440 AL User's Manual Vibrómetro y Tacómetro Láser Combinado Istruzioni per l`uso Alba 355 TM 9-2320-363-10 - JATONKAM35s HOME ON THE WEB concours et structure de master, les certificats, l`année de VR Manager Manual Copyright © All rights reserved.