1. CHAPTER 13 ADMINISTRATION AND MANAGEMENT 77 Ending Address The ending IP address of a contiguous block Enable SNMP AutoDiscovery A checkbox indicating whether Netmon should attempt to scan this range for SNMP capable devices If you do not want Netmon to perform automatic device discovery on this range uncheck this box Enable Background Port Scans A checkbox indicating whether Netmon should attempt to perform background port scans against devices in this range If you do not want Netmon to perform automatic port scans on this range uncheck this box Once the correct information has been entered press the Add Network button Modifying an IP Range To make changes to an existing IP Range locate it in the Manage Network Range s panel and click the Edit link next to the range you wish to modify Make the necessary changes to your IP Range in the Settings Editor window and then click the Update Network Range button Removing an IP Range from the Database To remove an IP range from the Netmon database simply locate it in the Manage Network Range s panel and click the Delete link next to the range you wish to delete Using the Netmon Update Service The Netmon Update Service is a background service that checks for new patches or updates for your Netmon product automatically every 24 hours This service is capable of updating any component of your Netmon system including e Operating System Security Updates e Background Se
2. When first created the name text will be highlighted and you a SNMP Walk Full can type a new name for the group o pil an ere You can add devices or existing groups to the group by clicking on the SNMP Trap Messages A 3 5 Linux Devi device s icon and dragging it onto the group icon Once a group has at 7 Qo Ps least one device or group inside it the icon will change to a folder icon s xavier office 10 10 1 20 4 C Network Devices To modify a group click on its name in the Device Explorer The center a misc pane of the Netmon interface will be replaced with a group management interface where you can edit the group name or delete the group When deleting a group you will be given the option to either delete all the devices and groups existing inside the group OR to delete only the group and place the devices and groups in it at the top level of the Device Explorer interface SNMP capable devices are identified with the following icons ou Designates a host device which has been automatically detected by Netmon as SNMP or NetFlow capable It is then up to you to activate one or both of these services on the device and assign the appropri Device Dashboard Designates a host device that supports SNMP lit is not strictly necessary to restart the Autodiscovery Service after changing the Community string However doing so will ensure that the service begins scanning using your new Commun
3. Sessions represent currently active users This table is used to track active sessions session variable can follow a user between requests and meta data allows the sessions to automagically expire allow users to be kicked out of the system etc Column Definitions Name Type Description session_userid int4 session_ttl int4 session_start int4 session_time int4 session_stack text session id varchar The session id is not sequence based It is generated by PHP using a uuid algorithm users Table Overview This table stores basic information about every user that has access to the system This table should be used to retrieve pager s email addresses and other personal information while triggering alerts or generating reports Column Definitions Name Type Description active int2 id int4 pager terminal varchar passwd varchar username varchar pager number varchar email varchar last_name varchar first_name varchar First name of the user CHAPTER 15 DATABASE REFERENCE 105 web_traffic Table Overview This table contains a list of HTTP requests which have been sent from hosts defined in your Local Network range s Column Definitions Name Type Description timestamp int4 id int4 dst_ip inet src_ip inet content_type varchar host name varchar url varchar URL requested
4. Monitoring Disks and Partitions Netmon provides system administrators with the ability to monitor the amount of free space on network connected disks and partitions Netmon can keep track of disks on Windows NT 2000 XP 2003 systems as well as Unix or Unix like hosts It can alert you when occupied space exceeds your defined threshold and can also help you monitor volume growth over time which helps in capacity planning Custom alert thresholds and notification parameters can be set for each share along with custom monitoring intervals and timeout periods How does Netmon monitor disks and partitions On Windows NT based systems Netmon uses the Server Message Block SMB protocol to connect to your shared folders The SMB protocol returns information to Netmon about the amount of free space on the disk On Linux and Unix type systems Netmon uses the df utility to work with inetd or xinetd super servers Netmon connects to the specified port number parses the df output and extracts the necessary disk infor mation Monitoring Windows Volumes Netmon can monitor public or administrative shares on Windows servers and workstations Adding a New Windows Share To monitor Windows shared folders and drives do the following 1 If you have not already done so create a shared folder on your Windows machine according to the security considerations listed below 2 Open the Disk Trackers console by clicking on Trackers gt Disk Tra
5. The Enterprise MIB folder contains proprietary enterprise specific MIB files which have been uploaded through Netmon s Custom MIBs feature You can view these files download them or print them If you see a A icon next to any file it means that Netmon does not recognize the file type The default action for these file types is Download Managing Netmon Log Files The Netmon Logs folder contains logging output for each of Netmon s background services such as the IP Protocol Analyzer or Syslog Server You may be directed to review these logs or send them via email to Netmon Technical Support personnel The size and contents of these log files depends on the level of logging verbosity you have specified in Settings gt Netmon Services If you see a A icon next to any file it means that Netmon does not recognize the file type The default action for these file types is Download 66 CHAPTER 12 FILE MANAGEMENT 67 Managing Traffic Capture Files The Netmon Traffic Captures folder contains cap files which have been created using Netmon s low level packet capture utility These files are prepared in a format which can be read and understood by Ethereal Wireshark client software Traffic capture files need to be downloaded to your local system for analysis They cannot be used from within Netmon itself If you see a icon next to any file it means that Netmon does not recognize the file type The default action for these file types
6. The Netmon Login Report displays a list of all Netmon login activity for the specified period of time To run a Netmon Login Report simply click the Netmon Login Report icon in the Netmon Report Explorer and take the following steps 1 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 2 Click the Generate Report button Panel Actions al Print an instant printer friendly report by clicking this button in the Netmon Login Report window Chapter 12 File Management The Netmon Files Manager console provides a central location for managing various kinds of files including data backups traffic captures proprietary SNMP MIBs and more Here you can view download or delete files as needed To use the files manager simply click the Files button in the top toolbar and then make the appropriate selection from the Folder Explorer on the left side of the window Managing the Backups Folder The Backups folder contains your Netmon data backups as well as various system level backup files including package repositories This is the location where you can view download or delete these items by clicking the appropriate link next to each item If you see a A icon next to any file it means that Netmon does not recognize the file type The default action for these file types is Download Managing the Enterprise MIBs Folder
7. In order to successfully import a MIB all of its dependent MIBs must already be present in the system If Netmon detects that a MIB being imported is missing any of these dependencies it may reject the upload with an error message You must identify the missing dependent MIBs usually by examining the IMPORTS declaration at the very top of the MIB definition Viewing a MIB Definition To view an uploaded MIB simply click on its name or select the View link in the Actions column next to the MIB you wish to examine CHAPTER 6 MONITORING DEVICES 42 Using the OID Tracker Service Netmon s SNMP OID tracker service allows you to watch a specific OID management point for changes This is an extremely flexible service that can be used to monitor hundreds or thousands of different performance metrics from SNMP capable devices S Terperanae in ilgab dagran am APC MPS Machap What is an OID An Object Identifier OID represents a single piece of information about your device OIDs belong to a much larger information repository known as a Management Information Base MIB A MIB is a tree like structure similar to the Windows Registry which has OIDs as its branches and leaves Many network devices can expose hundreds thousands or even tens of thousands of OIDs with each one representing some piece of data related to the configuration and operation of that device Browsing OIDs with the MIB Browser You can browse different bra
8. gt Netmon Services Features and Their Associated Background Service e Snmp Interface Monitor Bandwidth Activity Report Bandwidth Graphs OID Tracker Report e ip plugin Network Activity Report Conversation Report Bandwidth Consumption Report Visual Network Explorer Traffic e http plugin CHAPTER 13 ADMINISTRATION AND MANAGEMENT 81 Web Traffic report e Syslog Server Events and Logs Changing Service Startup Behavior By default Netmon is configured to start most background services when the appliance is booted How ever you may want to configure your system to start additional services or services on additional network interfaces upon a system boot You may also wish to turn certain services off at boot time To change the startup behavior for a particular service or plugin you change the Automatic Manual flag next to it Setting a service plugin to Automatic will tell your Netmon server to start that service plugin upon system boot Choosing Manual will tell your system to leave that service off at system boot Shutting Down and Restarting the Netmon Server Appliance To properly shut down or reboot the Netmon server appliance properly you ll need to log into the operating system console and issue one of the following commands Restarting the Server To restart the server appliance issue the following console command and press Enter when complete shutdown r now Shutt
9. in seconds Netmon should check the remote partition The default interval is 300 seconds 5 minutes but this can be set to any interval you choose Threshold When this amount of space is exceeded Netmon will trigger an alert The default threshold is 90 but this can be set to any amount you choose CHAPTER 9 MONITORING DISKS AND PARTITIONS 55 Modifying Disk Parameters To modify the monitoring parameters for a disk take the following steps 1 Open the Disk Trackers panel by clicking Trackers gt Disk Trackers 2 Click the Edit link next to the Disk you wish you modify 3 Make the necessary adjustments to your Tracker parameters and click the Update Disk button Removing a Monitored Disk To remove a monitored disk open the Disk Trackers panel and click the Delete link next to it You will be prompted to confirm deletion If you re sure click OK and the tracker will be deleted from your system Configuring Email or Pager Alerts for a Monitored Disk To configure email and or pager alerts for a disk open the Disk Monitoring panel and enter the IP address of the device Click the Alerts link next to the disk which is to be configured with alerts This opens the Alerts window for that particular disk where email pager alerts can be added or removed from the disk Chapter 10 Monitoring Websites and Web Applications Netmon can monitor websites and web applications by analyzing the results of an HTTP request You can u
10. option CHAPTER 5 MONITORING NETWORK SERVICES 31 Removing a PING or TCP Service Tracker To remove an existing service monitor take the following actions 1 Locate the service you wish to remove in the Trackers Explorer 2 Click the Del link which appears in the same row as the tracker you wish to remove 3 A confirmation window appears asking if you re sure you want to remove this service from the database If you re sure click OK otherwise click the Cancel button Chapter 6 Monitoring Devices Netmon has a wealth of features for monitoring highly detailed performance metrics on network connected devices such as routers firewalls switches servers printers UPS systems and more Introduction to Simple Network Management Protocol SNMP Effective network monitoring encompasses a broad range of responsibilities You need to understand your network traffic from several vantage points but it also becomes important to monitor the health availability and load of many different kinds of mission critical devices The solution is the Simple Network Management Protocol SNMP a widely supported monitoring and management protocol for network aware devices Managed devices as SNMP capable devices are otherwise known can include things like switches routers multi function printers fax stations firewalls thin clients wireless transmitters and much more Thousands of different devices support the SNMP protocol SNMP provides t
11. 25 results You can select various quantities of results up to No Limit 3 Set keyword filters To filter a report you must input both a keyword or word fragment wildcards are automatically added to the beginning and end of any text entered here and select a filter type Sender Recipient Subject or Attachment The input keyword will be matched against the selected filter type data ie if you set your keyword to info netmon ca and your filter type to Sender you will see only mails sent to info netmon ca in the output To add more filters click the button labelled to the right of the Keyword text box You can apply up to five filters to this report 4 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 5 Click the Run Report Now button Email Traffic Statistics The Email Traffic Statistics Report provides a high level summary of the non encrypted email traffic across a monitored network Broken down by the type of report output you select you will see a summary of the e mail messages sent and receieved their acerage and total size for the selected report period In order to run an Email Traffic Statistic Reports you must enable the IMAP POP3 and SMTP plugins for your sniffing interface in Settings gt Netmon Services To run an Email Traffic Statistics Report click Report gt Email TRaffic Statisti
12. Column Definitions Name Type Description id int4 description text name varchar OID name samp traps trans Table Overview This table is used to translate an SNMP trap s OID to a human readable format Column Definitions Name Type Description mib_id int4 id int4 trap_description text trap_name varchar trap_oid varchar OID of Trap snmpoids Table Overview This table is used to store the OIDs of received SNMP Trap messages If the store flag is set to true for an snmpoid record then Netmon will log all incoming traps for that OID Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description store bool id int4 snmpoid text ip inet IP address of device snmptrap_log Table Overview 102 This table contains historical SNMP traps which have been collected by Nemton s SNMP Trap Handler Column Definitions Name Type Description id int8 timestamp int4 port int4 trapoid text ip inet IP address of device snmptrapoids Table Overview This table is used to store the payloads of incoming SNMP traps messages Column Definitions Name Type Description log id int4 value text snmpoid text OID syslog Table Overview This table contains historical SYSLOG message data Column Definitions Name Type Description msg_id int8 sever
13. If the box is left unchecked Netmon simply records the latest result to the database Display on Home Dashboard If this is an important OID Tracker you can display it on the Netmon Home Dashboard Depending on the logging selection you have made see above this tracker will appear as a line chart or a single value panel Attaching Alerts to OID Trackers In addition to tracking OID values Netmon can notify you when the value of an OID exceeds a specific threshold For example you may want to be notified if CPU utilization exceeds 90 or if temperature in a rack enclosure exceeds 85 degrees or if the operational state of a service is anything except running To attach an Alert to an OID Tracker take the following steps 1 Locate the desired device in the Device Explorer window on the left side of the Devices console and click on it a 2 Click the OID Trackers button Es in the device toolbar 3 Locate the Tracker you wish to attach alert parameters to and then click the Alerts link next to it 4 Enter the comparison value and expression in the boxes provided and click the Add Alert button Netmon will evaluate the comparison expression at each polling interval If the comparison expression evaluates to false during any checkup an alert message is relayed Modifying an Existing OID Tracker To edit the tracker click Edit To delete the alerts for a tracker click Alerts next to the tracker and then press Del next to the alert
14. PRY A ORL EER a S LE 42 Using the Notes Manager oscura we ee ED RR ee wk Le 43 7 Monitoring Windows Systems 44 8 Monitoring SYSLOG and Event Logs 46 9 Monitoring Disks and Partitions 49 10 Monitoring Websites and Web Applications 11 Netmon Reports 12 File Management 13 Administration and Management 14 Troubleshooting Guide 15 Database Reference apo menlOW Gow vant che dee eh aARO REESE GE SDR EE ASUS SAR oe ed BSS SNMP IOS ck oe See ew A Me IE SRM A AOE EE A A alert commands e a s 24 0 a A Be er en SG e Le ee ss Sh ae we ae alert handler2comma d lt 4 402244084 dae Ree a PO be bee Ae ae ae Bae i alert hamdlers s eos st 6 4 6 3 nad id Bee ae a MAY ae doe ee ee be ede Oe be ee a alert mediaS s ace a ch AAA eA Sd e aaa Gb Ob AK doe oe eR i alert pend ig y y loas La a A e ee 2 hh ee a eee alert toper aie we ee A Ce Se he we lc we ae ed Le PICTUS VOCS rs pea do Gee a a ce Be Ge AE eg Be a a alert Were 444080086 e been EPE RS REEL She Dawe we SEARS HSE a Ree Bx backup events cask end ibSe eee oe CLEA SEO BH de hE hee Oe ee d DACkUPS se acs econ e Pee eee we ee ee be RWG Oe he eh a a ee Conditionals 20 noi as E MA BORER Oe we A Ae ae Oe aS ea ee A damong s ses uie Gath ae ee Bad Bee eh ob RE we Ge ee ee he a a bk a GSEMIONSCONHE nik ee ceed e baa de a ee ada e eS de he SES ROA OW A a A bia en ee de we OE A ES Se ee a ee ees is we Se ee Sees Gevices MObES iia ce ba a a BERG OR ORR BEER ES a be BRAM SER ES i Seb VOT arabe de
15. TUU netmon Netmon User Guide Version 5 2 Copyright 2011 Netmon Inc Contents 1 Hardware Support in Netmon SE 2 Hardware Support gn 445 444 eda G See Ra we a We ne he bd Gee le oe 2 2 Installation and Deployment Guide 6 Beginning the iistallation us ptas o be aE SR Ee hE OE Se ee 6 Debiansinstaller sra a Be hak Se aw ee ie ee bes oY owas 6 Network configuration with DHOP aisan Gee Peano eR eS a 7 Partitioning disks ds siria we ae ee RRs be ee ee be ol Oe de he ea 7 Package Installation 22 02 2403 6 4c0 be a Oe dae eS a A OWE A 7 Completing the installation lt lt lt sate a 4 S048 A e BAY EE OE ee ees 7 3 Getting Started 10 4 Monitoring Network Activity 17 5 Monitoring Network Services 27 6 Monitoring Devices 30 Introduction to Simple Network Management Protocol SNMP 0 30 Using the SNMP Automatic Discovery Service 2 aaau ee 32 Using the Devices Explorer sici soma 64 jad Pewee ees Ss hee GS RRA DS Se Ma we E 33 Using the Device Toolbar 2 4 Hibbe ts bbe behead ee ee dbates eu dadhws oa 35 Using the Interface Explorer o 24 64 4065 ob 8 466 REARS Ga BED Oe eee ee SH aw Sw eae 36 Device Dashboards vc a ac at Cie bee bra Meee A PH arse O 38 Browsing SNMP MIBS e s acca aaa Nui aana aha aie ie E i a A 38 Managing Custom SNMP MIBS c seged gugu a i ta ee ee ee eea aoe AR 39 Using the OID Tracker Service ica 0 240 ed a ha dade air bed wo i 40 Processing SNMP Trap Messages 54044 44 c0n 023
16. This table tracks individual events associated with Netmon backup Column Definitions Name Type Description timestamp int4 backup_id int4 id int4 event varchar backups Table Overview This table maintains a history of all previous Netmon backups Column Definitions Name Type Description init_timestamp int4 id int4 description text tables text status varchar notify varchar owner varchar Owner of the backup conditionals Table Overview This table contains a list of IP addresses which Netmon can use to perform secondary checks before queuing an alert See Alert Conditionals in the Netmon User Guide for more information on how Conditionals work Column Definitions Name Type Description cond_id int8 ip inet name varchar Friendly name for the conditional e g google daemons Table Overview Contains a list of installed background services daemons Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description start_auto bool id int4 description text name text component _type varchar daemonsconfig Table Overview Contains configuration parameters for various Netmon background services daemons Column Definitions Name Type Description id int4 daemon_id int4 docstring xml varchar value varchar var varchar Name of the config
17. account Adding a New User Account To add a new user account click the Add New User button in the middle panel This will cause the Settings Editor panel to open on the right side of the screen displaying a form for the entry of new user information To read more about each of these see Editing User Account Properties Modifying a User Account To update group membership an email address or other user details click the Edit link in the Actions column next to the account to be modified CHAPTER 13 ADMINISTRATION AND MANAGEMENT 71 Deleting a User Account To remove a Netmon user account simply click the Delete link in the Actions column next to the account to be deleted You ll be asked to confirm if this is what you really want to do If you confirm the selected user account will be removed from the system and logins under that account will no longer be permitted Suspending a User Account Suspending a user account has almost the same effect as deleting the account future logins for that account are disabled However when you suspend a user account you have the later option to re activate it This can be a useful option in cases where access should be temporarily disabled but not permanently revoked For example you may wish to temporarily disable the user accounts of technicians or administrators who are away on vacation To suspend an active account click Suspend in the Actions column To reactivate an account which has
18. ae ay Bi heed os ae Lea ae eS a Be Oa Be ee dad ed 98 SUMIDOS 24 bue e PARAS A Rea ee ed Ge hk ae hd ee a wd Bs 98 samp MID MES oa BEE ek wo eae EE ee UA od bh AS ee 99 SHMpPsO1d tans aia Boe a Ee OR OR a A e he eh a ee O 99 SIMP trapsatrans cc ee ea OG EPR OEE ERED SLRS eee RRR a RG eG 99 SMIMPOIUS 3 46564 b bo 64 wa eh Deeded CES CHE Mee e ca SEEDERS EO 99 Siiiptrap Oe s sans x ar OE PRA SES bed ad a FO he See 100 SOTOPtrapolds bes tee Rae ER RSME AA A OES Bee 100 SYSLOG ns AM Mee BE Re A Ne PEG we ee Re Se Ee eG 100 EOS CEOSS Gea GA a Os Ge ease ws Bele ee Ne yee cee arene ae A Set ea we ce ee a 101 UNO 5 44 80804 RASH A Oe AG RE ee ed Ge he a ea Mw ee Be 101 WES D Ad Ida ee he Be oh ee ee ee 101 o A dh eg tach oe at ah hein et GA ae ine a hd do He ee Ae ee ae 102 Ser SESSIONS oss ete A mG bk a Se oS ei ee BS ees Be RS ee 102 UBELS dei eee lk Gre bee ee ee dele eee A wo eo oe eh ah ek ed bee es a 102 WebAtaMme 4 Luca tea he od bei See eee aa la bbe ee de Hebe 103 Chapter 1 Hardware Support in Netmon SE Hardware Support Netmon is implemented on the Debian Linux operating system In theory Netmon will run on any device which meets the minimum hardware requirements for Netmon and runs Debian 5 0 for the x86 processor architecture In practice it is possible that device driver issues may cause problems in the normal operation of Netmon For this reason we cannot guarantee that Netmon will be fully functional on any har
19. automated operating system installation is known as Debian installer It uses a text based user interface In this interface the Tab or Right Arrow keys move forward and the Shift Tab or Left Arrow keys move backward between displayed buttons and selections The Up Arrow and Down Arrow keys select different items in a scrolling list The automated Debian Linux installer will perform various hardware auto detection routines and down load some basic software packages that are required for installation No intervention is required until you reach the Partition Disks prompt NOTE the following virtual console access should only be used by advanced users or under the direction of Netmon Support In the Debian installer there is a separate virtual console which error messages and logs are directed to You can see the output of this console by pressing Left Alt F4 To return to the main installer process press Left Alt F1 You can also access a separate virtual console to issue operating system commands by pressing Left Alt F2 To return to the main installer process press Left Alt F1 For more information on the Debian installer itself review the Debian GNU Linux Installation Guide Chapter 6 1 How the Installer Works If the automated Debian Linux installer does not suit your needs you can perform an unsupported manual installation by typing manual at the boot prompt Similar to installing Netmon SE on your own Linux
20. be configured to send an alert message Clearing Entries You can remove entries from the recently discovered hosts panel by checking off the entries you wish to delete then click the Clear Selected button There are also two additional buttons provided for convenience Check All and Uncheck All which allow you to select or deselect the entire list at once Configuring Alerts To configure alert recipients for newly detected hosts click the button on the Recently Discovered Hosts panel You ll be able to specify one or more alert recipients in the dialog window that follows CHAPTER 3 GETTING STARTED 16 Panel Top Activity Snapshot This panel gives you a high level overview of the 10 most active client server conversations over the last 60 seconds and also shows the TDP UDP port of each conversation If Netmon recognizes the port being used you ll see a friendly name instead of the actual TCP UDP port To get more information for the protocol s which are typically used on a particular port just click the friendly name i e HTTP or FTP and you ll be taken to a page in the Help amp Resources Panel which will tell you what Netmon knows about this port Netmon ships with a built in dictionary for over 50 protocols Each entry in this dictionary contains a high level overview of the protocol as well as links to helpful web resources for that protocol To get more detail for any host which is shown in this panel simply click on it This
21. be stored in a plaintext format Adding a New Note To add a new note to a specific device take the following steps 1 Locate the device in the Devices Explorer and expand the selection so that its sub items are visible 2 Click the Notes selection in the Device tree followed by the Add New Note button in the middle panel 3 Enter a subject line required for the note 4 Enter or paste the contents of the note into the Note textbox 5 Click the Save Changes button to commit the note to the database Modifying an Existing Note To modify an existing note take the following steps 1 Locate the note you wish to modify in the Notes Explorer and click the Edit link 2 Make any necessary changes to the note s subject or contents in the SNMP Manager window on the right side of the screen 3 When you have finished making changes click the Save Changes button to commit the updated note to the database Netmon also automatically records the date time that the note was modified Removing a Note To remove delete an existing note locate the note and click the Delete link next to the Note title Chapter 7 Monitoring Windows Systems Netmon can monitor your Windows services such as IIS FTP or any other program that runs as a Windows service This is done using SNMP so first you must configure SNMP support on your Windows system This can be done as follows Part I Enabling SNMP support on Windows 2000 XP 2003 Hosts
22. designers skipped the higher overhead of a full blown TCP connection in favor of a more graceful failure scenario Every managed device keeps a hierarchical database of values known as a Management Information Base MIB These MIBs are sent as numerical indexes known as object identifiers or OIDs in the SNMP packet 32 CHAPTER 6 MONITORING DEVICES 33 payload and each one represents some type of configuration detail Each MIB has an associated meaning such as the following MIB Cisco Router OID 1 3 6 1 4 1 9 1 1 The Good the Bad and the Ugly While it is certainly true that SNMP can provide you with a rich source of information for every managed device on your network s it also comes with a few drawbacks First off while SNMP is indeed a simple protocol its real world implementation is not very simple at all SNMP data is built around the idea that any kind of information can be stored and communicated by a managed device Of course different devices will want to communicate different kinds of data Switches will tell you how much traffic is going in and out of each port and so will firewalls but printers might tell you how many pages have been printed today or how much ink is left in each of the cartridges The result is that every device implements SNMP data structures in their own unique way and there are only a handful of standard OID MIB interfaces which are available across all types of devices This makes the task
23. e wy e rt eek Bey Beet a e gw ee oe ee A Gi Servers ao HESS RAPER SORE EE See Ga SEE SR eee A Bs FSECIECUONICS vs Se ea ea SR eR RM SA Ob Ee Bee ee bl Bada See wo d ml as Bi Mecho RE Gd de ae RS wee BS ee PA BA ows BR we Oh E A MOMS ira A ce aces amt che E eae aes a ea Bee iia a ee ii MOSH 3446662444 bore a ea headed wa bee bad dee hb db been amp S ipnored htt psextensions 2 44 5 6a aw dd ae ed dae eS doh i S44 R204 OW a Rae Re WIGERTACES ou ee A EAS A ee we es is we Se ee Se eS DECIMO econ de Besse ha SH rt BS Ee hy A A A a AAA AAA HELMON AUTE esla Bh Dea MES SS SD ee ee dt ke oe el eed OL NOE oe Gon Bie hak Be Ba ee GE eS AR SE ee BR A Wo de we oe a ok E OMS e se ee karts ace oat ees a te Eee cee eet ee eee ee Be amp ee es oe ee hee PermMissiOnZETOUPS s e gos dd bea a ede ve ewe atin e ds a e ew dls s permission categories s sii a a eR Ae A aS he A oe AA PERMISSIONS 5 20 godos o he we PES ee ee ee Sl Be BS We on GS eee SS eS PUPS nog woe ee ba OER EA EEG PREY SEL SEES ORES Se RAE Sa a Sa protocolcbr akdown 9 44 4 4 425444 448 Bhd 4 Ob Beh SS Sew BP eb Sheds a 54 56 64 66 80 PIGbOCOIS 455 nw oe RAE HR Ge ee RR Se S EGE GS RES a 96 ServerlOe sac bet Ga deb ee eh ieee ee Che Gee ee od os ED Ee Be 96 SOLVElS io Sa SSeS ea ened A HS SG Re eh ee AAA 96 sme KOStS me Lyk teas ee eae A es es es o 97 SMmbServerlog sica Bk ee eae Ww Boe RS wel GG wow wR DO be we 97 SMSE VOTS arlene cite ok Ss Ge agi
24. file systems such as ReiserFS or Ext3 with Netmon SE however there can be a significant loss of performance if a different file system is used For details on using the Debian utility for disk partitioning refer to the Debian Installation Guide for Debian 4 0 Section 6 3 2 Partitioning and Mount Point Selection Package Installation Once you have partitioned disks software installation will commence Software packages come from multiple sources and hence there are varying ways that package installation is represented on screen Some packages are installed from within the Debian installer and are represented with colourful progress bars Other packages namely security updates are installed by the Netmon installation script and are represented with text based progress indicators During the second phase of package installation the Linux console s built in screen saver may become active and blank the console Pressing any key on the keyboard will de activate the screen saver and restore the console view Completing the installation Once all operating system packages are installed you will be prompted to take out the installation CD and reboot your system After the reboot the Netmon software is downloaded and installed for you Once this CHAPTER 2 INSTALLATION AND DEPLOYMENT GUIDE 10 installation is complete the system will reboot once again and you will be presented with the GNOME graphical desktop login At the login prompt enter t
25. for the protocol server _log Table Overview This table contains a collection of server uptime and latency statistics over time Column Definitions Name Type Description srv_id int8 log_id int8 log_timeout int4 interval int4 latency int4 timestamp int4 message varchar status varchar Status when checked servers Table Overview This table contains a list of UNIX Linux disks volumes or partitions which are currently being monitored by Netmon Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description srv_id int8 log timeout int4 latency int4 timestamp int4 timeout int4 interval int4 port int4 ip inet pending varchar message varchar status varchar protocol varchar name varchar Label of server smb_hosts Table Overview smb_hosts inherits from hosts and adds the domain field to it Column Definitions Name Type Description id int4 timestamp int4 ip inet smb_domain varchar node_type varchar hostname varchar host_name_type varchar How the hostname was acquired smb_server_log Table Overview 99 This table contains historical disk utilization information for Netmon s Windows Share Monitoring Service Column Definitions Name Type Description srv_id int8 log_id int8 timestamp int4 blocksize int4 availa
26. install Debian 5 0 you will be able to determine with 100 accuracy whether your hardware will be supported by Netmon Be aware that the hardware test CD is a destructive test which will delete any pre existing data on your device s hard disk You can download the hardware test CD from the Netmon web site Tested Hardware The following hardware is known to work with Netmon Hewlett Packard We have certified the following systems from Hewlett Packard as working out of the box with Netmon 4 CHAPTER 1 HARDWARE SUPPORT IN NETMON SE 5 e BL465c G1 Blade System with p200 RAID array e DL380 G5 with p400 RAID array IBM e IBM x305 e IBM x306 Network Interface Cards If you are building your own server or have compatibility problems between Debian and the Network Interface Card NIC in your equipment you may need to purchase a NIC at retail Intel produces a number of network cards with gigabit support a gigabit NIC is recommended for Netmon The Intel Pro Desktop 10 100 1000 Gigabit PCI NIC has been tested successfully with Netmon This NIC was chosen because of its wide availability at retail Vendors with Debian support Hewlett Packard Hewlett Packard supports Debian Linux on the following models e BL20p G4 e BL25p G2 e BL460c BL465c BL480cL BL685c DL320 G5 DL360 G5 DL365 G1 DL380 G5 DL385 G2 DL580 G4 DL585 G2 For an up to date list and details on hardware support check the HP web
27. installation you will not be supported for any issues relating to the operating system if you choose to perform CHAPTER 2 INSTALLATION AND DEPLOYMENT GUIDE 9 a manual install For some classes of hardware or unique situations for example if you would like to use LVM to manage disk partitions a manual installation may be your only option Network configuration with DHCP The Netmon installer will attempt to configure your network interface card with DHCP for the purpose of downloading required software packages Once Netmon is fully installed you may manually configure the network using the graphical desktop environment If you do not have DHCP in your environment or if your DHCP server takes too long to respond the automated Debian Linux installer will display an error message and you will have the option to retry network autoconfiguration or to enter network settings manually Partitioning disks The Netmon installer will attempt to automatically partition your disk with the following partitions e A small swap partition 1 5 times the size of RAM e A 5 GB root partition e A partition consuming the remainder of the available free space mounted as var with the noatime mount option enabled In the event that the guided partitioning does not work you will have to manually partition your disks For best performance use the XF S file system and the partitioning scheme described above It is possible to use other
28. interface itself in the Device Explorer or locate it in the Network Interfaces branch of the Device Explorer tree and you 1l be brought to the Interface Explorer The type of graph you ll see depends on whether or not you ve enabled SNMP logging for that interface If SNMP logging is enabled for the interface you ll see a line chart showing inbound and outbound bandwidth utilization going back 30 minutes If SNMP logging is not enabled you ll see a bar graph showing the last inbound outbound traffic statistics for that interface Did you know You get an exact traffic figure for each point on the graph by holding your mouse over the data point Configuring Alerts for an Interface Netmon can send an email or pager alert when any specified interface goes above a user specified utilization To add or remove email or pager alerts simply click the appropriate selections from the Alert Management panel and choose Add or Del respectively CHAPTER 6 MONITORING DEVICES 40 Device Dashboards Device dashboards allow you to view key performance metrics such as CPU usage RAM and much more for several common platforms Expensive SNMP walks are no longer required to review the most common metrics Assigning a Dashboard to a Device To use a built in dashboard for your device take the following steps 1 Ensure that there is a dashboard for your particular device 2 Click the Devices button in the top toolbar 3 Locate your dev
29. is Download Chapter 13 Administration and Management Using the Settings Console The Netmon Settings console is where most administrative tasks are performed To open this console click the Settings button in Netmon s main toolbar and choose from a number of maintenance and administrative snap ins including Basic Setup Tasks Define Alert Conditionals Customize Alert Templates and Alert Commands Use Data Management Tools which can help you perform data backups Manage Traffic and Host Filters Manage Netmon s Host Name Database Define Local Networks for reporting and display purposes Manage Netmon System Services Manage the Port Label Database Manage Netmon User Accounts 68 CHAPTER 13 ADMINISTRATION AND MANAGEMENT 69 Fe pay a 273 Hole did Mt festes Ertl hago Fes E ran tas 1 E G terete 3 niwa dez ies E pj Mest Message Tengates Welcome i De lienor Resource Carder Te ae i Gases fx auch A aat aty accent da 6 complete set af aooo taesources y you enot sever E Fier Colcos Solana Ci tere t ear nare ast de ste AGN Jom booting Qiriut cae Beenie a Mero par Sera PEA Denon tauki gt Einicio 2 jonima Y ESTATE EE Whats hen e iba a Me y rrit zl ay 4D Managing Alert Conditionals What is an Alert Conditional An Alert Conditional provides fault tolerance for false alert situations Imagine what might happen if the Netmon server itself were to become disconnected f
30. of using SNMP data in a comprehensive monitoring or management system a non trivial undertaking SNMP management systems tend to be large unwieldy and tremendously expensive systems and their complexity can make one question the benefits of using SNMP in the first place SNMP and Security The introduction of any new protocol on the network merits some attention and SNMP deserves more scrutiny than most Unfortunately the most popular implementations of SNMP known as SNMP v1 and SNMP v2 are not particularly well known for their strong security In fact SNMP s security record is so dismal it has picked up a new dual meaning Security Not My Problem SNMP SNMP services and protocols are not necessarily a direct security threat themselves attacks on SNMP are relatively uncommon This is probably due to the fact that there are thousands of different implementations out there any kind of attack would likely have to be narrowly focused at a single device or class of devices However a much larger security threat exists with the information that SNMP makes available to a potential intruder SNMP data is transmitted in clear text which could pose a problem if you re sending certain kinds of information over a non private unprotected network such as the Internet In fact unfettered SNMP read access could allow an attacker to gather hundreds of configuration details about your network Many SNMP capable devices are shipped and installed wit
31. option devices Table Overview This table contains Netmon s master list of devices along with a series of flags which denote various device capabilities configured in Netmon Items in this table appear in the Devices Explorer Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description enable_sflow bool enable_netflow bool enable_snmp bool examined bool pending bool index int4 group_id int4 timestamp int4 interval int4 snmp _port int4 id int4 sysdescr text ip_address inet status varchar profile varchar snmp_community varchar label varchar Label for the device devices_notes Table Overview This table associates custom notes to specified devices Column Definitions Name Type Description last_modified int4 created int4 id int4 owner_id int4 device_id int4 note text subject varchar Subject of the note df_server_log Table Overview This table contains historical records for Netmon s UNIX Disk Partition Monitoring Service Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description srv_id int8 log_id int8 total int4 available int4 timestamp int4 status int4 Status of the monitor when check occured df servers Table Overview This table contains a list of UNIX Linux disks volumes or partitions which are currently being monitored by Ne
32. pointer is over the device icon With the mouse button held down move the device to the desired location and release the mouse The new location will be stored in the Netmon database and restored the next time you reload the map Map Icons The icon for each device is determined by the mapper based on information supplied by device dashboard settings If you would like a particular device to have a particular icon you can influence that by configuring the device for SNMP and selecting an appropriate dashboard If any trackers have been defined for a device it will be presented with an aura either red or green depending on the state of the trackers If you mouse over the aura a brief description of the tracker and its current status will be displayed in a tooltip At the top bottom and sides of the device icon there are four blue handles These handles are used to connect devices to one another Click on a handle and hold down the mouse button then drag to a corresponding handle on another device The mapper will create a persistent connection between the two devices Ungrouped Devices Once the mapper has exhausted all possible ways to identify connections between devices it will place any devices not yet connected into an area to the right of the autodiscovered map inside a box labeled Ungrouped devices Connect these devices to the appropriate infrastructure devices as described above and drag them out of the box as des
33. saved depending on your needs Creating and Saving Custom Reports You can save any of Netmon s core reports as a custom report for later retrieval To save a report simply provide a friendly Report Name in the text box which appears at the top of the Report Builder panel Then click the Save button to save the parameters you have entered When saving a report Netmon retains all of the information you enter except for custom date time ranges Network Activity Report The Network Activity Report allows you to query Netmon s network traffic database for any type of activity for any host To run a Network Activity Report simply click the Network Activity Report icon in the Netmon Report Explorer and take the following steps 1 Choose a source interface from the available drop down box You can select Netmon s built in Local Packet Analyzer or any NetFlow enabled interface 2 Choose a host or group of hosts to include in your query and make the selection in the Hosts selection boxes You can run a Network Activity report against All Hosts in the database or you can narrow your search by applying a host filter or specifying an individual host to scan You can even look for hosts which have a specific text pattern in their names 3 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 4 Choose the type of TCP IP traf
34. will take you to a page where that particular host can be explored much more thoroughly Panel Actions El Print an instant Quick Report by clicking this button in the panel 2 Refresh the display with new data by clicking this button Panel Top Web Destinations This panel shows the top web destinations based on HTTP requests averaged over the last 20 seconds To get more detail for any destination which is shown in this panel simply click on it This will take you to the Visual Network Explorer page where that particular host can be explored in more detail What is a Web Destination A web destination is simply the recipient i e the server of HTTP requests This could be any or all of the following e Public websites like www google com or www amazon com e Local intranets and web based applications e Non Web HTTP traffic i e SOAP or XML RPC calls Panel Actions al Print an instant Quick Report by clicking this button in the panel 2 Refresh the display with new data by clicking this button CHAPTER 3 GETTING STARTED 17 Panel Top Web Users This panel displays the top local hosts which are requesting HTTP web traffic Traffic rates averaged over the last 20 seconds are also provided for reference To get more detail for any host which is shown in this panel simply click on it This will take you to the Visual Network Explorer page where that particular host can be explored in more detail Panel
35. you wish to delete Note It is not possible to edit existing alert parameters To modify an alert you must delete it and create a new one CHAPTER 6 MONITORING DEVICES 44 Removing an OID Tracker To delete your new tracker simply press Del next to your tracker in the list of OID Trackers for that device All associated alerts for that OID will also be removed automatically OID Tracking Tips e The OID Tracker service is ideal for monitoring specific metrics that may not be exposed on a Device Dashboard In many cases hundreds or even thousands of data points are available but only a handful of the most common metrics are displayed on the dashboard e OID tracking is used to monitor the operating state of Windows services See Monitoring Windows Servicesfor more information e Choose an appropriate monitoring interval for your OID tracking metrics This saves processing re sources and also keeps your database size optimized For example you may want to monitor RAM utilization on your router as frequently as every 60 seconds while monitoring the pages printed on a network printer every 2 hours Processing SNMP Trap Messages Traps are messages that are sent by managed devices automatically in response to some activity or condition taking place Your Netmon system can process these incoming trap messages and can optionally log them to the database and or alert you when they arrive Sending SNMP Traps to Netmon In order for
36. you wish you modify 3 Make the necessary adjustments to your Tracker parameters and click the Update Disk button Removing a Monitored Disk To remove a monitored disk open the Disk Trackers panel and click the Delete link next to it You will be prompted to confirm deletion If you re sure click OK and the tracker will be deleted from your system Configuring Alerts for a Monitored Disk To configure email and or pager alerts for a disk open the Disk Trackers panel and click the Alerts link next to the desired Disk This opens the Alerts window for that particular disk where email pager alerts can be added or removed from the disk Security Considerations for Monitoring Windows Shares Monitoring a shared Windows folder requires that Netmon log in to the remote system with a valid username and password Since the transmission of a non encrypted user name and password across the network is a security risk use the following technique to ensure that Netmon can monitor remote Windows shares safely 1 Create a new empty share on the drive or partition you wish to monitor and set the access privileges for this share to read only Do not place any data in this folder 2 Create a separate user account on the target machine with the minimum access privileges required to access the monitoring share Monitoring Linux and Unix Partitions On Unix type systems Netmon uses the df utility to work with inetd or xinetd super servers
37. Actions al Print an instant Quick Report by clicking this button in the panel 2 Refresh the display with new data by clicking this button Panel Top Ethernet Protocols This panel shows you the most active Layer 2 protocol usage averaged over the last 20 seconds and ordered by the Ethernet frame type This panel is extremely useful to get an idea of your overall network traffic load It aggregates all traffic information for each major Ethernet protocol type and displays information for each Using this panel you can also monitor the usage of non TCP IP protocols like IPX SPX ARP as well as network bridging protocols like 802 1d Note that 802 1d is a much different protocol from the 802 11 wireless protocol suite On most TCP IP networks IPv4 both TCP and UDP should appear at the top of the list under normal network conditions Address Resolution Protocol ARP is a MAC to MAC addressing protocol is also generally present as well though at a much lower level ARP poisoning attacks could be monitored through this panel Panel Actions al Print an instant Quick Report by clicking this button in the panel 2 Refresh the display with new data by clicking this button Using the Help amp Resources Panel The Help amp Resources panel is a completely integrated one stop guide to your Netmon server appliance This panel is built right into the Netmon application and provides direct access to a rich variety of resources Using
38. If you have already enabled SNMP on your Windows system you can skip this step 1 Click Start gt Control Panel gt Add Remove Programs 2 Select the Add Remove Windows Components button 3 Ensure that the Management and Monitoring Tools option is checked 4 Click Start gt Control Panel gt Administrative Tools gt Services Locate the service called SNMP Service and make sure it is running 5 Right click the SNMP Service and select the Properties option 6 Select the Agent tab and make sure all the services are checked 7 Select the Security tab where you can configure the community string and which hosts SNMP will accept requests from Be sure to make a note of this community string You ll need to provide it to Netmon later 8 Click the OK button 9 Restart the SNMP service by right clicking on it and choosing Restart Service Part II Monitoring a Windows Service in Netmon Now that SNMP is running on your Windows server we can now configure Netmon to monitor Windows services This is done through the Devices section as follows 1 Click the Devices button in the Netmon top toolbar 2 Add the Windows device to your SNMP device list if it is not already present See Adding a New SNMP Device for more information Be sure you specify an appropriate Windows dashboard 3 In the Device Explorer click on the Windows device This will bring up its dashboard where you will be able to see various pieces of in
39. Modem for paging support Some features require SNMP capable equipment Also be aware that Netmon SE will not automatically install on hard disks significantly smaller than the minimum requirement although a manual install may be possible Keep in mind that with less than 40 GB of storage your Netmon device will be extremely limited in terms of its ability to keep historical data for any length of time Client System Requirements Netmon uses a web based client so requirements are fairly modest e Any operating system which provides a supported web browser e Supported Browsers Firefox 1 x or higher Internet Explorer 6 x or higher Opera 8 x or higher e Flash 7 0 or higher e Recommended 1024 MB of RAM Chapter 2 Installation and Deployment Guide Beginning the installation To begin installing Netmon SE insert the CD that came in your retail package or that you burned from the ISO image you downloaded into the computer you will use to run Netmon and start the computer Before doing so you should ensure that your computer s BIOS settings are configured to boot from the CD drive A boot screen will appear almost immediately At this screen you will be warned that the installation process is destructive and will erase any existing data on your computer s hard drive Consider the warning then type install at the prompt and press Enter to begin the installation process Debian installer The software which performs the
40. Netmon connects to the specified port number parses the df output and extracts the necessary disk information Note If you wish to monitor Netmon s own disk it is recommended you follow this method instead of the one described below On Solaris 10 inetd has become part of the smf service management system See below for details on this CHAPTER 9 MONITORING DISKS AND PARTITIONS 53 Adding a New Unix Partition inetd Method Use this method if your system uses inetd Monitoring a Unix partition requires a minor change to two configuration files on the remote system These files are called etc services and etc inetd conf 1 Insert the following line into etc services df 5001 tcp DF We have specified port 5001 here but you can actually choose any port number you wish However you ll have to remember to specify the same port number when adding this information to Netmon 2 Insert the following line into etc inetd conf df stream tcp nowait root usr bin df df k On some systems the df utility will not be located at usr bin df Search for the location of this utility with which which df If the output of this command does not match usr bin df then replace this bit of text in step 2 with the output of this command For example if the output of which is bin df You would modify the configuration line for etc inetd conf to read as follows df stream tcp nowait root bin df df k 3 Rest
41. Netmon to process SNMP trap messages you must first configure your SNMP device to send trap messages to Netmon s IP address Netmon expects to receive SNMP trap messages over UDP port 162 which is the most widely used port for this service Once you begin sending trap messages from your device Netmon will identify unique traps that arrive and record them in its database Once Netmon identifies a trap then you have the option of logging it and or attaching an alert to it Logging SNMP Traps In order to log an SNMP trap Netmon must first recognize it If you click the SNMP Trap Messages button you will see a summary of all trap messages which Netmon has identified To activate logging for a particular trap simply locate it in the list and click the Enable Logging button Netmon will then record incoming traps from that OID to its database Trap Alert Services If you d like to be alerted when a particular type of SNMP trap message arrives you must first enable logging for that trap see above Once you have enabled logging click the Alert al button next to the trap you wish to receive alerts for The SNMP Manager panel opens and you can add an alert recipient to the trap CHAPTER 6 MONITORING DEVICES 45 Using the Notes Manager Starting with Netmon 4 0 you can now associate one or more notes to specific devices Using this facility you can record service histories backup configurations and virtually any information that can
42. Number The Pager Number is usually the number that people dial when they wish to send you a page The Pager Terminal Number is a special access line provided by your paging company Instead of a voice prompt it provides a TAP compliant handshake to facilitate electronic communications with a system like Netmon for automated paging In most cases you ll need to contact your paging service provider to acquire this number Chapter 15 Database Reference agg _netflow Table Overview Contains aggregated network traffic data from the NetFlow Collector service This is the table which is used to construct Network Activity reports and Conversation Reports Column Definitions Name Type Description octets int8 out_iface int4 in_iface int4 timestamp int4 lowest _port int4 flow_sre inet dst_ip inet src_ip inet Source IP Address agg snmp_log Table Overview Contains aggregated bandwidth utilization information for SNMP devices Column Definitions 84 CHAPTER 15 DATABASE REFERENCE 85 Name Type Description outresets int8 outoctets int8 inresets int8 inoctets int8 agg_log_id int8 timestamp int4 interface int4 ip inet IP Address of SNMP client alert_commands Table Overview This table contains the custom commands to be triggered while dispatching alerts Column Definitions Name Type Description p
43. To Netmon Registration Code 20110303412 Version Ya License Type 52 500 devices 1 Netmon inc Alinmants Username and Password for Initial Login If you are logging in for the first time use the User ID admin with a password of netmon Once you log in it is recommended that you complete the Initial Setup Tasks located in the Settings console Performing Basic Setup Tasks There are 4 quick steps which should be taken immediately after logging in for the first time These steps allow Netmon to begin discovering devices and services automatically and also ensures that alert messages can be properly relayed To start the Setup Wizard click the Settings button in Netmon s main menu at the top of the screen and look for the Initial Setup Tasks link Click on it and then click each of the 4 items in turn 1 Define your Network Range s see Managing Network Ranges 2 Configure SNMP Automatic Discovery see Using the SNMP Automatic Discovery Service 3 Set up Netmon User Accounts see Managing User Accounts 4 Alert Testing Utility see Troubleshooting Email Alerts CHAPTER 3 GETTING STARTED 14 Setting Up Traffic Sniffing In order for Netmon s packet analyzers to work properly it must receive a copy of the packets going across your network This is accomplished using port monitoring also known as port mirroring or port spanning on your switch Most enterprise switches support this feature The steps to enable port monito
44. affic by clicking on Networks and noticing that traffic is being displayed in the Visual Network Explorer Introducing the Netmon Home Dashboard The first screen you will see after logging into the system is the Netmon Home Dashboard This screen is designed to provide you with a high level up to the moment overview of your network CHAPTER 3 GETTING STARTED 15 me tes abis MID Dic tags Paget Fes qc det ici dea ye AE vso Y PORE Pares TUDO Raver 132 78 0 1 ae anus wh LEIDO trimmis de a BUS tee AYRE St ai bs ABEL shite se i 1 BUDO Ly etmon Help h Resource entes jeans ta fe detras Resource Conte Pa ares a deme by gi emy artes D a orgie set af support remus fy yar hemon eer ayine ad here egr mor det fs het P du r Qik 1 AA ES sia ake CELE HAASI Porc 4580 Panel Recently Discovered Hosts The Netmon network autodiscovery service detects new MAC IP pairs on your network and can alert you of this situation if you wish You can locate this panel at the top right of Netmon s Home dashboard It displays any recently detected MAC IP pairs These entries remain in the panel until they are cleared How Network Auto Discovery Works Netmon uses the Address Resolution Protocol ARP to probe for new hosts on your local segment s It issues periodic ARP broadcast requests and checks the responses it receives against its database of known MAC addresses When a new MAC address is detected Netmon can
45. ag anything individual hosts or even the map itself to navigate the display more easily To select a host and view additional details about it simply double click on it Double clicking will display the Active Connections Panel for that particular IP address which displays all of the current network connections coming from or arriving to that device Customizing Your View The Visual Network Explorer can also be manipulated in a number of ways to help you refine your perspective and narrow your focus on specific host s and or activities Traffic View Traffic view provides two distinct ways to view the network traffic itself which is represented by a series of dotted or solid lines in between individual hosts Each of these methods provides advantages in specific situations Absolute View displays all network traffic on an absolute scale Each packet stream is displayed according to the maximum speed your infrastructure can support usually 100 Mbps or 1 Gbps For a reference on what each style of line represents see the Activity Legend Using Absolute View is usually the best way to monitor traffic if you re trying to understand your overall network load Relative View displays traffic according to the most active packet stream on the network In this scenario the most active conversation on your network is displayed with a thick bright red line see the Activity Legend and all of the other conversations are scaled in a linear f
46. ame Type Description id int4 timestamp int4 ip inet node_type varchar hostname varchar host_name_type varchar Type of hostname SMB host Custom name DNS resolved name etc ignored _http_extensions Table Overview This table contains a list of file extensions which will be ignored by Netmon s HTTP Request Analyzer service CHAPTER 15 DATABASE REFERENCE 93 Column Definitions Name Type Description id int4 extension varchar interfaces Table Overview This table contains Netmon s master list of network interfaces It is closely related to the devices table as each interface in this table belongs to an entry in the devices table Column Definitions Name Type Description enable_shm bool enable_logging bool homedisplay bool shm_key int8 last_outbound int8 last_inbound int8 speed int8 outresets int4 inresets int4 device id int4 interface int4 id int4 last_outbound throughput floats last inbound throughput float8 mac varchar description varchar name varchar Name of the interface localnets Table Overview This is a catalog of local networks on which the netmon box sits Netmon uses the ranges defined in this table for several services including the Background Port Scanning Service and ARP Probe Service Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Des
47. an GNU Linux device driver check page This page allows you to paste the output of the Linux shell command lspci n into a text area and get a report showing the driver support provided by the Linux kernel Keep in mind that the kernel version used in Netmon SE currently 2 6 18 may vary from the kernel version used by this page which may result in inconsistent information e Linux Documentation Project Hardware HOWTOs This page provides a set of task oriented guides HOWTO documents in the Linux world for configuring hardware on Linux e Linux Compatible Hardware Database This page provides a searchable database of hardware components with details on their compatibility with Linux e Netmon Community Forums The Netmon community forums are a place where you can interact with Netmon Inc staff and other Netmon users You may find useful information about hardware in the forums If you don t feel free to ask questions about your particular scenario CHAPTER 1 HARDWARE SUPPORT IN NETMON SE 7 Customer Reported Hardware Customers have reported successful installations of Netmon SE on the following hardware devices e Sun Fire X4200 System Requirements For best performance your Netmon server should have the following minimum performance specifications Hardware Requirements e Pentium 4 processor or equivalent e 1024 MB RAM e 40 GB Hard Disk SATA recommended e 10 100 NIC Gigabit NIC recommended e 56k
48. ant to trim Netmon s name database by deleting inaccurate or outdated names To delete any name simply click the Delete link in the Actions column beside the particular name which you wish to remove You ll be prompted to confirm that you really do wish to delete this name from the database If you re certain click the OK button to proceed and Netmon will remove the name from its database CHAPTER 13 ADMINISTRATION AND MANAGEMENT 76 Adding a User Defined Host Name You can apply your own friendly host name to any IP address Click the Add New Host button in the Manage Hostname Database panel An editing window will open in the Settings Editor panel on the right side of the screen Enter the IP address and label and then click the Add Hostname button Your IP address will now appear as your friendly label throughout the Netmon application Managing Filter Collections One of the most powerful features in Netmon is the use of filters Filters allow you to look for specific kinds of traffic or narrow your view to a certain set of IP addresses or both You can use filters in the Visual Network Explorer VNE and they can also be used when creating reports Netmon uses two kinds of filters Traffic Filters Traffic filters allow you to refine your view or a report to look for specific TCP or UDP ports or protocols You can look for an individual protocol port combination i e UDP 514 or you can include a wide range of different po
49. art inetd with the following command killall HUP inetd Alternatively you can use the following command kill HUP lt inetd PID gt On a Solaris 10 system restarting inetd will have no effect you must instead convert the inetd conf entries into the new format inetconv This will convert your service definition to the smf format 4 Open the Disk Trackers panel located in the Trackers console 5 Click the Add New Disk button on the Disk Monitoring panel and choose UNIX for disk type 6 Fill in the following fields then click the Add Disk button IP Address This is the IP address of the UNIX host Port Specify the port number to which Netmon must connect This should be the same port number as entered in Step 1 above Partition Enter the device name of the partition i e dev sdal or dev hdal CHAPTER 9 MONITORING DISKS AND PARTITIONS 54 Timeout Specify how long in minutes Netmon should spend trying to connect to the remote host The default timeout period is 5 minutes but this can be set to any interval you choose Interval Specify how frequently in seconds Netmon should check the remote partition The default interval is 300 seconds 5 minutes but this can be set to any interval you choose Threshold When this amount of space is ex ceeded Netmon will trigger an alert The default threshold is 90 but this can be set to any amount you choose Adding a New UNIX Partition xinetd Method Use this method if your s
50. ashion according to this host CHAPTER 4 MONITORING NETWORK ACTIVITY 22 Relative View is the best option to use when you want to compare your network traffic to other network traffic It allows you to see how traffic from individual hosts compares against the traffic betweenother active hosts Conversations Using this feature you can customize your view to show the Top 16 Top 32 Top 48 or Top 64 conversations Viewing fewer conversations at once can simplify the view while viewing many conversations at once can give you a broader perspective View Hosts By You can choose to view individual hosts by their IP address or by their host name If you choose to view by Host Name Netmon displays the host using its friendly name if one is available If a friendly name is not available Netmon selects the first entry in its name database giving preference to NetBIOS names followed by DNS names Apply Traffic Filter Using this selection you can apply any one of Netmon s traffic filters to the VNE display Click here for more information on traffic filters Apply Host Filter Using this selection you can apply any one of Netmon s host filters to the VNE display Click here for more information on host filters Zoom This tool lets you change the zoom level from 50 to 250 Simply click on any zoom level or you can drag the Zoom handle to adjust your zoom visually Host Legend e Inia Internal Non Routable IPs These hosts are displayed
51. be prompted to confirm deletion Once a command has been deleted from this area any existing alerts which may have called that command will continue to function however they will no longer run that command Sophisticated Alert Response Mechanism SARM Overview The most significant update to Netmon 4 5 to date is the introduction of a new facility that allows you to configure custom commands to be executed when an alert is triggered You can create your own scripts use built in commands available as part of the Debian GNU Linux Operating System or use some of the commands we have created just for you Alert commands are associated with alert Types and you can create edit delete Response Commands by clicking on the Settings button of the top toolbar then clicking on the Alert Message Templates item in the tree Some alert templates will not display the command association dialog in order to avoid redundancy with other templates Creating Alert Commands After clicking on the alert template that is of interest to you you will see a new area at the bottom of the template dialog with a form that allows you to configure your new command The form contains the following fields e Label The value you enter in that field is the Name of your command and is the value Netmon will use to populate the Command Association dropdown when you create a new alert Pick something that briefly describes what the command does e Co
52. been previously suspended click Reactivate in the Actions column Managing Account Groups Account groups allow you to logically group individual Netmon user accounts and bind them to a specific set of permissions that is common between them For example you may want to prevent network technicians from deleting data or making changes to Netmon s configuration while providing senior administrators with more control Netmon ships with four built in account groups You can modify the individual permission settings in each of these groups create your own groups or even remove groups that are not required in your environment Administrators By default this group has full control over the Netmon software application It is strongly recommended that you do not change the permission structure of this group nor should it be removed Backup Users This group is only permitted to perform backup operations such as configuration backups database compact operations and complete data backups Standard Users This is the normal account group that should be used for most of your Netmon user accounts It grants access to the entire Netmon application but prevents members from deleting data or performing administration functions Report Users By default this group has read only access to the entire Netmon application but is pre vented from altering data or performing system administration or maintenance functions You can customize the individual perm
53. bel database click Settings gt Port Label Database Adding a New Port Label To add a new port label to Netmon s database press the Add New Port Label button which makes an editing window visible Enter the following values in the boxes provided Transport Layer Choose between TCP and UDP Port Number Provide a valid port number from 1 to 65535 Label Enter a brief 36 character maximum friendly label to apply to this protocol port combination Once the correct information has been entered press the Create Port Label button Modifying a Port Label To change an existing port label click the Edit link next to the label you wish to modify An edit window will appear in the Settings Editor on the right side of the screen Made the desired changes to the transport protocol port number or label and click the Update Port Label button to save your changes Removing a Port Label from the Database To remove a port label from the Netmon database simply click the Delete link next to the particular label you wish to delete You ll be prompted to confirm each delete operation Built In Protocol Dictionary If an entry for a particular protocol exists in Netmon s protocol dictionary Netmon displays it when you click the protocol s friendly label If Netmon does not recognize the protocol a generalized entry is displayed Managing Netmon System Services Netmon uses a variety of background services known as daemons in the UNIX wo
54. ble int4 total int4 CHAPTER 15 DATABASE REFERENCE 100 smb_servers Table Overview This table contains a list of Windows shared folders volumes which are being monitored by Netmon Column Definitions Name Type Description srv_id int8 threshold int4 timestamp int4 blocksize int4 available int4 total int4 status int4 interval int4 timeout int4 1p inet pending varchar message varchar domain varchar servername varchar password varchar username varchar share varchar Name of SMB share to monitor snmp_log Table Overview This table contains historical bandwidth utilization data for network interfaces being monitored by Net mon s SNMP Interface Monitor service Column Definitions Name Type Description outresets int8 outoctets int8 inresets int8 inoctets int8 log_id int8 status int4 timestamp int4 interface int4 ip inet pnotified bpchar notified bpchar CHAPTER 15 DATABASE REFERENCE 101 snmp_mib_files Table Overview This table contains a reference of all the user uploaded SNMP MIB files in the system Column Definitions Name Type id int4 mib_path varchar mib_file varchar Description Name of mib file snmp_oid_trans Table Overview This table stores the OID to human readable names It is populated through calls to mib2xml
55. ce stops running Modifying an Existing Windows Service Tracker To edit the tracker click the Edit link next to your tracker in the list of OID Trackers for that device Note It is not possible to edit existing alert parameters To modify an alert you must delete it and create a new one 1Don t see this header on your device dashboard It is most likely that you have not associated the correct Windows dashboard to the device See Device Dashboar for more information on assigning a dashboard to your device Chapter 8 Monitoring SYSLOG and Event Logs Using the Event Log Explorer Netmon s built in SYSLOG server allows you to manage SYSLOG and event log data from a variety of hosts in a single integrated console Coon ASA 5500 80 0 1 Dace ASA 5500 90 LI 48 CHAPTER 8 MONITORING SYSLOG AND EVENT LOGS 49 Setting Up SYSLOG Clients In order to manage event log data in Netmon you must first configure your SYSLOG capable clients to send log messages to Netmon s IP address Important Netmon expects to receive log data over UDP port 514 Most SYSLOG message systems should be configured by default to send messages over this port However if you re not seeing expected SYS LOG data in Netmon you may want to ensure that your client software is configured to use this protocol port combination Once you have configured your client device s take the following steps in Netmon 1 Click the Manage SYSLOG Clients
56. cessfully 0 otherwise alert_triggers Table Overview The alert_triggers table stores conditions that the system will attempt to match against the status of a particular service or device to determine whether or not to trigger the associated alert which will in turn be dispatched through the use of the associated alert_handlers Column Definitions CHAPTER 15 DATABASE REFERENCE Name Type Description active bool triggered bool throttle_interval int4 trigger_id int4 trigger_timeout int4 trigger_threshold int4 reference_pkey_val int4 comp _exp varchar label varchar pattern varchar reference_table_name varchar Name of reference table alert_types Table Overview This table describes the conditions that constitute an alert situation Column Definitions Name Type Description id int4 original_template text default_template text default_subject varchar description varchar name varchar Type name of the alert DF_SERVICE_DOWN etc SMB_ABOVE_THRESHOLD alert_vars Table Overview This table describes what elements are available for a specific type of alerts Column Definitions Name Type Description id int4 alert_type_id int4 label varchar var_name varchar Name of the var that the C back end will export backup_events Table Overview CHAPTER 15 DATABASE REFERENCE 88
57. ckers 3 Click the Add New Disk button on the Disk monitoring panel and choose Windows for disk type 4 Fill in the following fields and then click the Add Disk button Domain Name This is the name of the domain or workgroup to which the host belongs IP Address This is the IP address of the Windows host Username This is the login or account name which has permission to access the share Password This is the password for the account which has permission to access the share 51 CHAPTER 9 MONITORING DISKS AND PARTITIONS 52 Share Name If you have entered a valid domain IP address username and password this field will automatically display a list of available shares If the information supplied is invalid an error message will appear here Timeout Specify how long in minutes Netmon should spend trying to connect to the remote host The default timeout period is 5 minutes but this can be set to any interval you choose Interval Specify how frequently in seconds Netmon should check the remote share The default interval is 300 seconds 5 minutes but this can be set to any interval you choose Threshold When this percentage of space is exceeded Netmon will trigger an alert You can enter any value between 1 and 100 Modifying Disk Parameters To modify the monitoring parameters for a disk take the following steps 1 Open the Disk Trackers panel by clicking Trackers gt Disk Trackers 2 Click the Edit link next to the Disk
58. cking the Enable NetFlow checkbox when you click on it in the Device Explorer Once this step has been completed you ll see a purple NetFlow icon E next to the device in the Devices Explorer 3 Enable NetFlow for the desired interface s which are sending NetFlow packets to Netmon by opening each interface and choosing the Enable NetFlow option Sending NetFlow Data Streams to Remote Devices Netmon can provide summarized traffic data in NetFlow format to remote devices This functionality is designed for Netmon to Netmon communications but may also work for other consumers of NetFlow data To configure the Netmon NetFlow emitter click on the Settings button on the Netmon menu bar In the Settings explorer click on Netmon Services Scroll down the list of services to find the netflow emitter plugin Click the configure link that is to the right of the plugin name CHAPTER 4 MONITORING NETWORK ACTIVITY 21 You can now specify the IP and UDP port of the target machine s the log level for the plugin and the aggregation period in seconds for the emitter Note that the IP and port should be specified in the format XXX XXX Xxx xxx yyyy If multiple targets are required they should be specified separated by a comma Click the update button next to any values you change in the configuration settings Once this is complete click again on Network Services scroll down to find the netflow emitter section and
59. connected See How Netmon Monitors Traffic above for more information Monitoring E mail Traffic Netmon has the capability to monitor and record email activity across the sniffed network To enable or disable this capability take the following actions 1 Configure your environment and Netmon for traffic sniffing as detailed in the Getting Started guide 2 Enable or disable the E mail traffic plugins In Settings gt Netmon Services look for the three plugins e IMAP Plugin to monitor IMAP traffic e POP3 Plugin to monitor POP3 traffic e SMTP Plugin to monitor SMTP traffic Collecting NetFlow Data Streams from Remote Devices You can use Netmon to monitor and record live network activity on remote networks using Cisco s NetFlow protocol suite Netmon can accept and process NetFlow v1 v5 and v7 datagrams Important In order to properly process incoming NetFlow packets you must also enable SNMPv2 GET on the device which sends NetFlow packets to Netmon This allows your Netmon system to properly identify all of the network interfaces on the device Activating NetFlow There are three steps required to monitor NetFlow data from remote devices 1 Configure your remote device s to send NetFlow packets to your Netmon server appliance Once Netmon detects incoming NetFlow data for a particular device it will automatically add that device to your Devices Explorer tree 2 Enable NetFlow data collection for the newly added device by cli
60. cription enable_portscan bool enable samp discovery bool id int4 label varchar broadcast varchar network varchar Network IP range netflow Table Overview This table is a temporary storage location for incoming NetFlow datagrams Every 30 minutes data from this table is aggregated into agg_netflow and the contents of this table are truncated Column Definitions Name Type Description packets int8 octets int8 protocol int2 out_iface int4 in iface int4 timestamp int4 end_time int4 start_time int4 dst_port int4 sre_port int4 flow_sre inet dst_ip inet src_ip inet Source IP address netmon Table Overview This table is used internally to track registration information Column Definitions 94 CHAPTER 15 DATABASE REFERENCE 95 Name Type Description devices int2 company_country varchar registration_key varchar contact_phone_ext varchar contact_phone varchar contact_email varchar contact_last_name varchar contact_first_name varchar company _state varchar company city varchar company_address varchar activation key varchar company_name varchar expires date is_trial bit netmon auth Table Overview This table contains a record of Netmon login activity Column Definitions Name Type Description timestamp int4 id int4 ip inet medium varchar status varchar us
61. cs and take the following steps 1 Choose a report type Available types are e Address Summary of emails sent and received by email address Client Summary of emails sent and received by client IP Domain Summary of emails sent and received by email domain Server Summary of emails sent and recieved by server IP For the purposes of the Email Traffic Statistics Report a Client is any system sending SMTP messages to a server or receiving POP IMAP traffic from a server and a Server is any system receiving SMTP messages or sending POP IMAP traffic 2 Select a keyword filter If desired type some text into the text box labeled Keyword Filter to only see results for values of the selected report type matching the filter text For example to only see statistics for emails sent to and from the domain netmon ca select Address as the report type and fill in netmon ca in the keyword filter 3 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 4 Click the Run Report Now button CHAPTER 11 NETMON REPORTS 63 Latency Report The Latency Report analyzes all of the TCP Service Trackers PING Service Trackers and Disks which have been configured in the Netmon Trackers console and provides an average latency in milliseconds for each service for the time interval specified Please note that in ord
62. d click the Update button or press ENTER to save your changes CHAPTER 6 MONITORING DEVICES 37 Removing an SNMP Device To remove an SNMP device take the following steps 1 Locate the device you wish to remove in the SNMP Device Explorer and click on the main device node 2 Locate the Remove Device button in the detail window and press it You ll be asked to confirm that you really want to delete this device If you re sure click OK to proceed with the delete operation Caution Deleting an SNMP device can take a long time because all of the historical data that was collected for it must also be deleted Depending on the size of your database this procedure could take anywhere from 10 seconds to several minutes or more Using the Device Toolbar The device toolbar appears at the top of all device related pages It corresponds to the collapsing menu which can be seen in the Device Explorer tree so you can use whichever navigation style you prefer O To see a brief description for any toolbar button simply hold your mouse over it a bd S SES SI Ea Device Dashboard Return to the home dashboard for this device is Device Notes View notes history for the selected device al Network Activity View network activity statistics for the selected device or manage network activ ity monitoring preferences If the selected device does not have a Dashboard associated with it this page be comes
63. dware not tested by Netmon Inc directly or in production use by one of our customers Generally the riskiest areas in terms of hardware support are networking and video A buggy network driver can be very problematic A video card which works well with Debian is important since Netmon uses the graphical desktop for some configuration utilities such as configuring the network card As time goes on the list of hardware that has been tested and verified to work with Netmon will grow Beyond the list of Netmon certified hardware and depending on your appetite for risk there are a number of options in determining whether your equipment is likely to work with Netmon Some hardware vendors such as Hewlett Packard explicity detail the level of support on their hardware for Debian Linux A list of these vendors is provided here It is very likely that Netmon will work well on any device that explicitly supports Debian 5 0 lenny Although products from vendors offering support for other Linux distributions may work be careful since each distribution of Linux varies in many particulars including driver support Occasionally the Debian project excludes drivers from their distribution for technical legal or political reasons and this may limit the effective support for some hardware To help bridge this gap Netmon provides a hardware test CD which performs the same automated Debian install that is performed when installing Netmon By using this CD to
64. e take the following steps in Netmon 1 Click the New Device button at the top of the SNMP Device Explorer 2 Enter the IP address of the device into the IP Address field 3 In the Label field specify a friendly name for your device such as London Office Router 4 Choose a sampling interval and enter it into the Sample Every text box Netmon uses a default value of 180 seconds but you can specify any interval you like 5 Enter the community string that your SNMP managed device requires in order to answer SNMP v2 queries 6 Be sure the Enable SNMP checkbox is checked 7 If you anticipate receiving NetFlow data streams from this device check the Enable NetFlow checkbox Otherwise leave it unchecked Alternately if you anticipate receiving sFlow packet samples from this device check the Enable sFlow checkbox Only one of these two checkboxes can be enabled at one time 8 Click the Add Device button Note Once you have added a new SNMP device it can take Netmon several minutes or more to discover all of the interfaces and begin gathering SNMP data In some cases it could take as long as one hour for data to appear in Netmon s console Updating an Existing SNMP Device You can update the sampling frequency community string or friendly label of any SNMP device by doing the following 1 Locate the device you wish to modify in the SNMP Device Explorer and click on the main device node 2 Update the necessary fields an
65. e which means that it will capture all broadcast traffic for the entire network segment being monitored regardless of whether or not port monitoring is correctly configured 82 CHAPTER 14 TROUBLESHOOTING GUIDE 83 Troubleshooting Email Alerts Here are some tips for troubleshooting Netmon s email alerts 1 Click Settings gt Initial Setup Tasks gt Alert Testing Utility 2 Choose an appropriate Recipient from the available list 3 Click the Send button Netmon will attempt to send a test alert message to the specified recipient You will see the output provided by your mail server in the window If the alert was relayed successfully you ll receive it by email along with an OK message in the output window If the alert was not relayed successfully you will see the error message returned by your mail server in the output window The most common problem seen here is that the mail server is not configured to permit the Netmon server appliance to relay email messages Troubleshooting Pager Alerts Here are some tips for troubleshooting Netmon s pager alerts e Be sure the modem on your Netmon server appliance is connected to a dial tone via the supplied telephone cable This line should be a plain analog line similar to what would be required for a FAX machine Certain phone systems do not provide a dial tone that is usable by the Netmon server e It s important to distinguish between the Pager Terminal Number and the Pager
66. e Internet interfaces on the Home page Simply toggle the checkbox on or off and click the Update button to save your changes Interface Monitoring Options Several different options can be set for monitoring specific interfaces To set these options click the desired interface in the Device Explorer and you will see available options in the Settings Editor window in the top right of the screen Label By default Netmon uses the ifDesc value in the MIB tree to label the interface However you can apply your own custom labels to an interface by entering a new value here Display on Home Dashboard This checkbox sets whether or not a graph will be shown for this interface on the Netmon home dashboard Enable SNMP Logging This checkbox sets whether or not to record historical bandwidth utilization data for this interface in the database The length of time that data is kept depends on the historical data policy you set for the SNMP Interface Monitoring Service and can range from 1 day to forever When this checkbox is selected you ll see a icon next to that interface in the Device Explorer Enable NetFlow This checkbox sets whether or not Netmon should expect incoming NetFlow packets from this interface When this checkbox is selected you ll see a E icon next to that interface in the Device Explorer SNMP Interface Graph The SNMP interface graph shows the input output information for that interface To view the interface graph click on the
67. e of the initial Netmon setup tasks for you Administrator Account The first form in the deployment wizard is the Administrator Account On this form enter your contact information and a desired username and password This will be the first administrative account for Netmon Once you have completed filling out the form click Next Step to proceed to the next form Network Ranges After the administrator account has been created the Configure Network Ranges form will appear In this form you can add any significant network ranges for your environment In the Label field enter a meaningful value for your environemnt like Wired LAN In the field labelled Starting IP Address enter the first usable IP address in this range In the field labelled Ending IP Address enter the last usable IP address in this range be sure to avoid including the subnet broadcast address If you would like to auto discover SNMP devices in this range check the SNMP Discovery checkbox If you would like this network range included in the port scan report check the Port Scanning checkbox Once you ve completed the values for a network range click the button labelled Add Range Do not click Next Step without first adding the network range to the list or you will lose your work CHAPTER 2 INSTALLATION AND DEPLOYMENT GUIDE 11 Configure SNMP Auto Discovery Settings Once you have defined network ranges the Configu
68. ed to enter a valid date and time range 5 If desired check the Delta Report option by clicking the checkbox When this option is checked Netmon plots the rate of change of the management object over the desired time interval as opposed to absolute values 6 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the OID Tracker Report window CHAPTER 11 NETMON REPORTS 64 URL Tracker Report A URL Tracker Report allows you to evaluate the performance of websites and web applications You can monitor the performance latency of URL request delivery as well as accuracy expected results returned through the same report Note In order to run a report for any URL Tracker you must first ensure that the Enable Logging selection has been checked in the URL Tracker Manager To run a URL Tracker Report take the following steps 1 Choose URL Tracker Report from the Netmon Report Explorer 2 Select a URL from the available list If no URLs are visible see Note above 3 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 4 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the URL Tracker Report window Port Scan Report A Port Scan Report summarized the results of Netmon s backgrou
69. er to run a Latency Report for a specific device service you first need to enable full historical logging for that device service By default Netmon does not keep historical data for devices or services for performance reasons To run a Latency Report simply click the Latency Report icon in the Netmon Report Explorer and take the following steps 1 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 2 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the Latency Report window OID Tracker Report An OID Tracker Report allows you to examine historical values for any SNMP management object OID through Netmon s OID Tracker Service Though this is a very simple report it is extremely flexible and useful for a variety of tasks Note In order to run a report for any OID Tracker you must first ensure that the Enable Logging selection has been checked in the OID Tracker Manager To run an OID Tracker Report take the following steps 1 Choose OID Tracker Report from the Netmon Report Explorer 2 Select a Device from the available list If no Devices are visible see Note above 3 Choose an OID Tracker from the available list 4 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will ne
70. erform_on_recovery bool perform_on_failure bool async bool id int4 timeout int4 alert_type_id int4 command varchar label varchar Label associated with this canned command alert_handler2command Table Overview This table maintains the associations between alert handlers and custom alert commands Column Definitions Name Type Description command_id int4 handler_id int4 Foreign key that refers to alert_handlers id alert_handlers Table Overview Netmon s email and pager alerting mechanism relies on this table to determine how an alert should be dispatched Column Definitions CHAPTER 15 DATABASE REFERENCE 86 Name Type Description alert _template_id int4 trigger_id int4 id int4 required_retries int4 user_id int4 conditional_id int4 media_id int4 Foreign key for the media alert_medias Table Overview Contains information on how alerts are dispatched Column Definitions Name Type Description id int4 name varchar pager sms email console etc alert_pending Table Overview Catalog of alerts waiting to be re processed Column Definitions Name Type Description dispatch_timestamp int4 trigger _timestamp int4 id int4 retries_processed int4 handler_id int4 parsed_alert_message text parsed_subject varchar sent bit 1 if this alert has been dispatched suc
71. ername varchar User name oid_log Table Overview This table contains the historical values of OIDs which are being monitored by Netmon s OID Tracker Service Column Definitions Name Type Description oid_id int8 timestamp int4 id int4 message varchar Message of the log entry CHAPTER 15 DATABASE REFERENCE oids Table Overview This table contains a list of OIDs being monitored by Netmon s OID Tracker Service Column Definitions Name Type Description homedisplay bool enable_logging bool timestamp int4 interval int4 device_id int4 id int4 prev_message varchar datatype varchar label varchar message varchar Message for the OID permission2groups Table Overview Many to many relationships allowing groups to be assigned individual permission bits Column Definitions Name Type Description group_id int4 permission_id int4 The ID of the permission permission categories Table Overview This is a catalog of the categories available for each permission for sorting and clear presentation of permission bits Column Definitions Name Type Description id int4 name varchar Name of the major category e g User Management Administration Reporting etc permissions Table Overview 96 CHAPTER 15 DATABASE REFERENCE 97 Permissions are simple bits that t
72. ets traveling across the network segment which is being monitored This is typically accomplished using a feature called port SPANning or port mirroring where your switch has been configured to forward all packets to a specially designated monitoring interface Method 2 NetFlow Protocol NetFlow is a perfect choice for monitoring remote networks from a centralized location By using the NetFlow protocol your remote devices typically routers perform packet inspection of all traffic going into and out of various network interfaces Summaries of this activity are then forwarded as flow packets to a NetFlow capable monitoring system like your Netmon server appliance Method 3 sFlow Protocol sFlow provides packet samples instead of statistical summaries as with NetFlow Because of the nature of the VNE short term monitoring and the inherent statistical error in small samples this interface is only marginally useful in comparison to the packet analyzer or NetFlow facilities However in some cases sFlow might be the only data source you have for a remote network 19 CHAPTER 4 MONITORING NETWORK ACTIVITY 20 Using Netmon s Built In Protocol Analyzers Netmon features several built in protocol analyzers which are designed to gather information which passes across either of Netmon s two gigabit network interfaces Netmon s native protocol analyzers are generally used on networks to which the Netmon device is physi cally
73. face to schedule a maintenance window during which the alert will not be triggered Once a maintenance window has been created it will be listed in the information box and can be deleted by clicking delete next to the schedule description Managing Alert Message Templates Netmon allows you to customize the alert messages which are sent from various monitoring facilities through the use of simple templates Simply navigate to Settings gt Alert Message Templates and expand the tree to see a complete list of available templates CHAPTER 13 ADMINISTRATION AND MANAGEMENT 73 Customizing an Alert Message Template To customize any template select it from the available list in the Settings Explorer An editing window will appear showing the current alert text In any alert message special information is inserted such as the name and IP address of a service which has failed for example via specially tagged keys into the template These keys look like host or ip_address and they help Netmon to understand where to place important alert information You can insert these tags anywhere in your template using the specially provided buttons Simply position the cursor where you d like to place the data and then click the desired button on the right side of the editing window You can also use standard cut amp paste tools to move tags around your message You must click the Save Template button to permanently commit any changes you make to a
74. fic to scan You can scan for All Activity or you can narrow your search by applying a traffic filter or specifying an individual protocol port combination 5 Finally you can limit your result set and choose the ordering of the information with the Limit Results To and Order Results By selection boxes 6 Click the Generate Report button 58 CHAPTER 11 NETMON REPORTS 59 Panel Actions El Print an instant printer friendly report by clicking this button in the Network Activity Report window Conversation Report The Conversation Report allows you to examine network activity between two hosts or two groups of hosts To run a Conversation Report simply click the Conversation Report icon in the Netmon Report Explorer and take the following steps 1 Choose a source host or group of hosts to include in your query and make the selection in the Source Host s selection boxes You can run a Conversation Report against All Hosts in the database or you can narrow your search by applying a host filter or specifying an individual source host 2 Choose a destination host or group of hosts to include in your query and make the selection in the Destination Host s selection boxes You can run a Conversation report against All Hosts in the database or you can narrow your search by applying a host filter or specifying an individual destination host to scan 3 Choose a reporting period Available choices are Today Yesterday Last 7 Day
75. formation for the target system You will also see a section called Services 46 CHAPTER 7 MONITORING WINDOWS SYSTEMS 47 Summary Click on the link below the header to see a list of Windows services 4 Locate the service you wish to monitor and click the Add Tracker button hal 5 Enter the Label you wish to use for the tracker Netmon will pre fill the OID value here svSvcOper atingState but it is a good idea to over write this label with the name of the service you are monitoring 6 Choose how often you want it to sample Sample Every whether you want this tracker logged or not and check off Display on Home Dashboard if you would like this tracker to appear as a Dashboard on your home screen 7 Click Add Tracker to finish 8 Now that the tracker is added we can attach an alert onto it to send us emails when the tracker value changes To do this select OID Trackers under the device in Device Explorer and click Alerts next to the tracker we just created Windows uses the following values for service status 1 not present or not running 1 running 2 continue pending 3 pause pending 4 paused 9 Here you can set up your alert Enter a Label for this alert and select a Recipient and the Media Type by which to send the alert Enter a Value Threshold of 1 and select Comparison Expression to be Not Equal 10 Click Add Tracker to finish 11 Your alert is now set up You should receive an alert when a Windows Servi
76. h weak or well known SNMP community strings A community string is the closest thing to a password in SNMP v2 and earlier devices so it s incredibly important to ensure that you change these strings to strong passwords that meet modern security standards Fortunately some of the most pressing security issues have been resolved with SNMP v3 the latest and greatest implementation of this protocol Encrypted traffic is now supported along with much stronger authentication mechanisms However there are still relatively few devices which support this new implemen tation of the protocol despite its age nearly 7 years at the time of writing In the meantime you should review your managed devices and evaluate their roles in your monitoring strategy Check for the following 1 Does the SNMP service on this device need to be active at all Do I really need to gather performance data from this device In many cases the answer is Yes 2 Is the Community String set to a strong password phrase CHAPTER 6 MONITORING DEVICES 34 3 What kind of SNMP data is being polled from this device Is it safe for this information to traverse the LAN WAN Internet 4 Have SNMP write operations been disabled SNMP s Role in Network Monitoring SNMP has a few warts but can nevertheless occupy a very effective role in an overall network monitoring strategy Despite the rich variety of information it makes accessible SNMP really shouldn t be used t
77. he ability to query and update a managed device remotely Using this protocol you can retrieve a potentially rich set of information about a particular device data such as inbound and outbound traffic levels current connections CPU load memory status usage history error messages device status and countless other details This is really nice stuff to know Furthermore SNMP write operations can even allow devices to be configured and managed remotely Devices can also be configured to automatically push SNMP data to a remote monitoring or management system For example you might configure a laser printer to send information about current toner level These UDP datagrams are known as SNMP traps and they re generally sent to a remote monitoring system where they re collected and handled appropriately Netmon 3 5 will feature an SNMP trap handling engine The SNMP Protocol The SNMP protocol itself is a relatively simple request response protocol It works at the application layer and typically utilizes UDP ports 161 and 162 The choice of UDP may seem a bit unusual for a request response protocol but SNMP was designed from the outset to move across the network as non critical traffic In high load situations UDP packets that are dropped from the network are not resent by the originating host This reduces network congestion in critical load situations To ensure that SNMP traffic doesn t unnecessarily burden a network its
78. he system uses to determin is a specific user is allowed to perform a specific action at some point in time Column Definitions Name Type Description id int4 category _id int4 name varchar Name of the permission e g create_new_users delete_users edit_users activity_report portscan_report etc plugins Table Overview The plugins db table contains all plugins which are used by netmon daemons Netmond reads the content of this table loads and starts all plugins who have start_auto set to t Plugins which are dlls or shared object are found in usr local lib Column Definitions Name Type Description start_auto bool daemon_id int4 id int4 description text running_ifaces varchar start_ifaces varchar name varchar Name of the plugin protocol_breakdown Table Overview This table is used to provide data for Netmon s Protocol Breakdown graphs NetFlow Column Definitions Name Type Description timestamp int4 end_time int4 start_time int4 device int4 interface int4 id int4 ports _int4 octets int8 CHAPTER 15 DATABASE REFERENCE protocols Table Overview This is a catalog of protocol ports pairs similar to etc services Column Definitions Name Type Description id int4 threat_level int4 port int4 name varchar protocol varchar Transport layer protocol
79. he username netmon and the password netmon to gain access to the desktop Configuring the network card On the Netmon GNOME desktop you will find a number of icons including one labeled Network Admin To configure your network card with a static IP address double click this icon You will immediately be prompted to enter the root password which is netmon Once in the network administration tool itself on the tab labeled Connections select the network interface you would like to use with Netmon and click the Properties button You can now choose between DHCP and static settings and fill in the appropriate settings for your network You can also use Network Admin to configure your DNS settings Click the OK button in the interface properties window then click OK in the Network settings window Activating Netmon Once initial setup tasks are complete you will be prompted for your product activation key as well as your contact information Once you have activated Netmon the Deployment Wizard will start Netmon Deployment Wizard On the Netmon desktop you will find an icon labeled Web Browser Double click this icon to launch the Debian fork of the Firefox web browser which will open the Netmon web interface by default The first time you connect to the Netmon web interface you will be presented with the Netmon Deployment Wizard This is a set of four forms which will take car
80. hich have been attached to this tracker On the other hand if you are monitoring a specific service such as port 80 on a web server or port 25 on an email server Netmon uses TCP CONNECT method to determine if a service successfully responds to a basic 3 way handshake request If the handshake fails Netmon triggers the appropriate email and pager alerts which have been defined for the service monitor Introducing the Trackers Console The Trackers console is where most of Netmon s availability tools are located To open the Trackers console click the Trackers button in the top toolbar Creating a New PING or TCP Service Tracker To monitor a new device or service take the following steps 1 Click the Trackers button in the top toolbar and then click the TCP Service Trackers or Ping Trackers button 2 Click the Add New Tracker button at the top of the Trackers Explorer This opens the Tracker Manager panel 3 Transport Protocol In the Tracker Manager panel choose the type of monitor TCP or ICMP TCP is used to monitor network services and ICMP is used to monitor devices 4 IP Address Enter the IP address of the host to be monitored 5 Friendly Name Enter a friendly name label for the host to be monitored 6 Port If you have specified a TCP service to be monitored enter the Port number here A valid port number is any number between 1 an 65 535 29 CHAPTER 5 MONITORING NETWORK SERVICES 30 7 Interval The monit
81. ice in the Device Explorer on the left side of the screen When you find your device click on its name This will open the device s current dashboard 4 Locate the SNMP Manager window on the top right corner of the screen 5 Make the appropriate dashboard selection in the Device Dashboard drop down box 6 Click the Update Device button Troubleshooting Dashboards e Device dashboards require appropriate SNMP support on the monitored host If SNMP services are not enabled on your target device you will not be able to retreive any dashboard data for that device e In addition to SNMP support on the target device Netmon also requires the appropriate MIB file s which match the target device profile in its own MIB repository These MIB files are in most cases stored in your Netmon system automatically but it is possible to inadvertently remove them in Netmon s MIB File Browser e Not all metrics will necessarily be exposed by all devices which belong to a particular classification In these cases some metrics will be unresolved Browsing SNMP MIBs How Netmon Retrieves Management Information CHAPTER 6 MONITORING DEVICES 41 Netmon uses the SNMP Walk facility to explore the exposed Management Information Base MIB tree for a particular device Caution SNMP Walks can be very resource intensive operations and have been known to crash some older devices You should always exercise caution when walking mission critical devices e
82. in green i e subnets 192 168 x x 10 x x x 172 x x x etc e 43 101 190 100 External Routable IPs These hosts are displayed in orange i e any IP address not included in above non routable ranges e 192 168 1 255 Broadcast IPs Broadcast hosts do not actually physically exist and are displayed with a purple label as well as a special icon 0 e eee Highlighted Any host which has been highlighted with the mouse hovering over it turns blue Hint Click and drag CHAPTER 4 MONITORING NETWORK ACTIVITY Activity Legend Line Style Absolute View Relative View 32 Mbps and above Most Active Host 16 Mpbs and above 8 Mbps and above 4 Mpbs and above 2 Mpbs and above 1 Mpbs and above 512 Kbps and above 256 Kbps and above 128 Kbps and above 64 Kbps and above 32 Kbps and above 16 Kbps and above 8 Kbps and above 4 Kbps and above 2 Kbps and above Under 2 Kbps Least Active Host Other Panel Actions Le this button will realign the display for you 23 al Print an instant Quick Report of the current VNE display by clicking this button Realign Map If you ve moved the map too far and have lost your view of the hosts and or activity CHAPTER 4 MONITORING NETWORK ACTIVITY 24 Using the Network Topology Mapper The Network Topology Mapper NTM or mapper provides a persistent view of the str
83. ing Down the Server To restart the server appliance issue the following console command and press Enter when complete shutdown h now Chapter 14 Troubleshooting Guide Finding Help Need help with your Netmon server appliance We re here to help For Registered Product Subscribers assistance is just a call or click away e Use the Live Chat feature on the Netmon website http www netmon ca support e Email us at supportQnetmon ca e Call us toll free at 1 800 944 4511 Troubleshooting the Packet Analyzer Here are a series of tips for troubleshooting Netmon s packet analyzer No Visible Traffic e Ensure that one or both network cards are plugged into a port on the switch which is receiving a copy of all of the network traffic through port forwarding SPAN port mirroring or a similar mechanism e Ensure there is a valid network link by verifying that the network jack itself displays a flashing or solid green light for both network cable connections e Be sure you have not applied a traffic filter or host filter in the Visual Network Explorer which is not present on your network causing no devices and traffic to be shown in the VNE Seeing Partial Traffic e If you re seeing mostly broadcast traffic directed to x x x 255 addresses and only a few instances of other types of activity chances are that port forwarding is not configured correctly your switch Netmon s secondary network card operates in promiscuous mod
84. ired CHAPTER 4 MONITORING NETWORK ACTIVITY 25 Panel Active Connections This panel shows you all active connections during the last 60 seconds for the selected IP address To use this panel you simply enter the IP address of the host you wish to explore and then press ENTER Alternatively you can double click on any host in the Visual Network Explorer window to see all Active Connections for it Host 10 10 1 16 slo If Netmon s network sniffer detects any active connections for the selected IP address they will be displayed in the Active Connections Panel window Each data stream is separated into its own row Traffic Stream Direction The direction of the traffic stream is displayed with an icon as follows This data is request traffic Data from the selected host is being uploaded to the remote host which ap pears in this row This data is response traffic Data from the remote host which appears in this row is being down loaded to the selected host Host The name or IP address of the destination host The selected IP address has established a connection to this host If the host name can be resolved Netmon displays the name of the host here If the IP address resolves to multiple names Netmon displays the first hostname in its database along with a icon which can be clicked to expand the list Port Netmon identifies the TCP or UDP port of the data stream and shows it in this column If Netmon
85. issions in this group to allow disallow access to specific areas of Netmon Understanding Permission Inheritance A user account can belong to one or more groups When a user account belongs to two groups or more the user inherits all available permissions from both groups Group A has permissions X and Y Group B has permissions Z A user who is a member of both groups inherits permissions X Y and Z Viewing Group Details To quickly view expanded details for an account group click the Details link in the Actions column next to the desired group CHAPTER 13 ADMINISTRATION AND MANAGEMENT 72 Adding a New Group To add a new user account click the Add New Group button in the middle panel This will cause the Settings Editor panel to open on the right side of the screen displaying a form for the entry of new group information To read more about each of these see Modifing Group Properties Modifying a Group To update permission assignments for an existing group click the Edit link in the Actions column next to the group to be modified Check uncheck the desired values and click the Update button in the Settings Editor panel Deleting a Group To remove a Netmon account group simply click the Delete link in the Actions column next to the group to be deleted You ll be asked to confirm if this is what you really want to do If you confirm the selected group will be removed from the system Note You should not remove the Admini
86. its dashboard a 4 cana Events and Logs Review Syslog and Event Log history for the selected device SNMP MIB Walk Full Performs an SNMP walk on all known branches of the management tree Depending on the amount of management information exposed by the selected device this operation can be a resource intensive operation In extreme cases it can take up to one minute for the walk to complete a sl SNMP MIB Walk Enterprise Performs an SNMP walk on the enterprise specific branches of the management object tree This operation is less resource intensive than a full SNMP walk a onl SNMP Object OID Trackers Browse OID object trackers for the selected device SNMP Trap Messages View SNMP trap messages which have been sent by the selected device to your Netmon system Click here to learn more about Netmon s SNMP Trap Handler Service CHAPTER 6 MONITORING DEVICES 38 Using the Interface Explorer The SNMP Interface Explorer provides a detailed view of a specific device interface For switches routers firewalls and other networking oriented devices each of these interfaces could represent a physical Ethernet network jack or they could also be virtual interfaces such as those used for VLANs and local loopbacks dre PROA Basic Interface Information Netmon displays the following information for the selected interface Interface This is the interface number reported by the device Speed This is the maximum speed of
87. ity regardless of protocol Order Results By You choose to produce a report for each individual IP address selected as Source Network s or you can produce a report which summarizes the data for each network subnet range Running a Bandwidth Consumption Report To run a Bandwidth Consumption Report click the Bandwidth Consumption Report icon in the Netmon Report Explorer and take the following steps 1 Choose Source Network s from the available drop down selection 2 Choose Network s to Exclude from the available drop down selection 3 Select a reporting period You can choose from any one of several pre defined values or specify a custom time interval by choosing the Custom option 4 Choose a Traffic Filter if desired to limit the protocols which are included in the reporting results 5 Click the Generate Report button Panel Actions El Print an instant printer friendly report by clicking this button in the Bandwidth Consumption Report window Disk Activity Report The Disk Activity Report allows you to plot disk utilization over a specified time interval To run a Disk Activity Report simply click the Disk Activity Report icon in the Netmon Report Explorer and take the following steps 1 Choose a disk share or partition to include in your query and make the selection in the Disk Share Partition selection box 2 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you cho
88. ity int4 facility int4 timestamp int4 ip inet message varchar The syslog message CHAPTER 15 DATABASE REFERENCE 103 syslog_access Table Overview This table contains a list of SYSLOG clients which Netmon will accept incoming SYSLOG messages from Column Definitions Name Type Description syslog_id int8 severity int4 facility int4 ip inet IP address of syslog client url_log Table Overview This table contains the historical status of websites and web applications being monitored by Netmon s URL Monitoring Service Column Definitions Name Type Description url_id int8 latency int4 timestamp int4 id int4 status varchar message varchar Message of log entry urls Table Overview This table contains a list of URLs being monitored by Netmon s URL Monitoring Service websites and web applications Column Definitions Name Type Description enable_logging bool latency int4 timestamp int4 interval int4 id int4 status varchar message varchar pattern varchar url varchar URL to monitor CHAPTER 15 DATABASE REFERENCE 104 user2groups Table Overview This many to many relationship allows users to belong to multiple groups Column Definitions Name Type Description group id int4 user_id int4 ID identifying the user entry user_sessions Table Overview
89. ity string right away If the service is not restarted Netmon will complete its current scan using the old Community string CHAPTER 6 MONITORING DEVICES 36 Li Designates a host device that supports NetFlow packet streams m Designates a host device that provides sFlow packet samples Designates a host device that is not responding to SNMP queries To view a high level overview of a device and all of its interfaces simply click the device in the SNMP Device Explorer which displays a global view of the device along with a summary view for each interface Input and output is displayed on an LED style graph To drill further down and view detailed information for each individual interface simply click the port icon next to the device and select an interface node from the tree by clicking on it This will bring up the SNMP Interface Explorer window which provides a detailed view of that specific interface Adding a New SNMP Device First you must enable SNMP v2 GET requests or polls as they are sometimes known on your managed device This process varies from manufacturer to manufacturer so consult the documentation for your device to determine what steps are necessary to enable this capability Be sure to specify or take note of the device s Community string The Community string is essentially a password for retrieving SNMP data and this string will need to be provided to Netmon Once you have enabled SNMP on your managed devic
90. ks If you are not monitoring Windows disks with Netmon you can safely turn this service off Configuring Individual Services Many Netmon Services have customizable settings For example the Email Alert Service allows you to specify SMTP settings for outbound mail alert messages and the Packet Analyzer Service allows you to adjust your historical data retention policy for that service To configure custom parameters for specific services click the Configure link next to the associated service You ll be brought to a page where you can configure all available items for that service Data Retention Policies Netmon stores data for a specified period of time This ensures the disk will not get filled up with data as the services continue to log network traffic and other information over long periods of time Netmon allows you to configure how long data will be stored in the system for each background service This is configured under Settings gt Netmon Services gt configure gt data_archival The data_archival setting is specified as weeks A data_archival setting set to 6 weeks will mean that data will be deleted a month and a half after it is recorded Below is a reference to point you towards which background service you will want to edit the data retention policy for In the below list find the feature you want to limit data retention for find the service name above it and click configure next to that service name in under Settings
91. le port select the Range option which enables text to be entered in the Range text box Enter the port number in this box and then click the Scan button To scan a range simply enter a starting port a dash and an ending port i e 1000 2000 Scanning Firewalled Hosts Scanning a firewalled host can be a good way to ensure that the firewall is exposing only absolutely necessary services Keep in mind however that scanning a firewalled host tends to take much longer than an equivalent scan against a non firewalled host This is due to the fact that firewalls do not acknowledge connections on any port which is not permitted to pass through Thus the port scanner must wait until a specified timeout period has been reached before it can determine that a port is truly closed Scanning a fully firewalled host i e a host in which no ports are open or a host which has been configured to ignore ICMP PING requests can result in a Host is unresponsive or behind a firewall message In practice a fully firewalled host should not appear to exist at all so port scans against them are generally pointless Microsoft Windows XP SP2 machines have a particularly draconian firewall and when they have been configured for maximum security they generally ignore inbound network requests entirely CHAPTER 4 MONITORING NETWORK ACTIVITY 27 Port Scanner Legend Symbol Icon Port Range Ports 0 to 25 Ports 26 to 50 Ports 51 to 75 P
92. ly added to the commands list located right under the alert creation form You can click on the delete link beside any of the commands to delete it or click on the Edit link to display an edit form which you can use to update your command Associating Commands to individual Alerts Builtin Alert Response Scripts Examples Pix Response Example Portscanning new hosts that join your network Restarting IIS on a Windows WebServer Managing Host Names Using this console you can manage Netmon s name database which contains a variety of NetBIOS DNS and user defined host names Each of these host names maps to an IP address and often many different host names map to the same IP address This console allows you to manage names for any host and even to include your own user defined labels as well as search Netmon s database for host names which match a particular search criteria Searching for Hostnames To search Netmon s name database enter a search string in the Search Text IP Address box on the Hostname Management console For example to search for all hostnames which contain the text google simply enter google into the Search Text IP Address box Then click the Search button If you wish you can customize your search to NetBIOS names only DNS names only HTTP Requests only or user defined names only Removing a Host Name In some cases a host name may no longer be accurate or relevant In these cases you ll w
93. mmand Enter the command Netmon will execute when the alert is triggered This is typically the name of your command followed by specific arguments You can pass any of the variables available on top of that dialog to your command by clicking on the variable s button e Process Asynchronously If you select this option Netmon will first dispatch the alert notification and then execute the specified command This is useful if you want to ensure your alerts will be dispatched quickly but not recommended because you have no way of finding out if your command has failed e Add output to Alert If selected Netmon will first execute the specified command collect its complete output and then add the output of the command to the alert notification message This means that Netmon must wait for your command to finish executing before it can send the alert We recommend using this setting but you must also make sure that your command can complete in timely fashion to ensure you will receive your alerts CHAPTER 13 ADMINISTRATION AND MANAGEMENT 75 e Conditions Use the Process on Failure and Process on Recovery checkboxes to instruct Netmon to execute the command when the alert condition is first met and also when the alert condition is no longer met This allows you for example to have Netmon execute your command when a server goes down and then again when that same server comes back up Upon creating your command it will be immediate
94. ms This feature can often identify failing services before a complete stoppage has occurred To add an email alert take the following steps 1 Choose a user account from the drop down list in the Email Alert column 2 Choose a value for Max Latency You can choose Service Down or a latency value from 100ms to 1500ms 3 To attach a Conditional to this alert select the appropriate Conditional from the available drop down list If no Conditionals are configured NONE is the only option Complete the action by clicking the Add Alert button Click here for more information on Conditionals Removing an Existing Alert To remove an alert which has already been set click the Delete link next to the associated alert Modifying a PING or TCP Service Tracker To modify the tracking parameters for a device or service which has already been set up take the following steps 1 Locate the device or service you wish to modify in the Trackers Explorer 2 Click the Edit link which appears in the same row as the selected service This opens the Tracker Manager window and displays all of the configurable information for this particular service Some items cannot be changed such as the IP address or the Protocol Port information 3 Once you have made your desired changes click the Update Tracker button 1If you want to be able to subsequently create a Latency analysis report for a particular device or service choose the Log Everything
95. n invalid response from your website s or web application s To attach an email or pager alert recipient to an URL Tracker take the following steps 1 Click the Trackers button in the top toolbar followed by the URL Trackers button 2 Locate the URL Tracker you wish to attach an alert to and click the Alerts link next to it 56 CHAPTER 10 MONITORING WEBSITES AND WEB APPLICATIONS 97 3 Assign the alert a Label if desired This step is optional 4 Specify a Netmon user account to be the alert recipient 5 Specify the Alert Media to be used email or pager 6 Specify one or more Alert Command s to associate with the alert condition if desired and if available 7 Click the Add Alert button Modifying a URL Tracker To modify an existing URL Tracker take the following steps 1 Locate the URL Tracker in the URL Tracker Explorer and click the Edit link next to it 2 Make the desired changes to the URL Tracker paramters 3 Click the Update Tracker button Removing a URL Tracker To remove an existing URL Tracker take the following steps 1 Locate the URL Tracker in the URL Tracker Explorer and click the Del link next to it 2 You will be prompted to confirm deletion If you are sure click OK 3 The URL Tracker will be deleted Chapter 11 Netmon Reports To access the Netmon Reports console click the Reports button in the top toolbar Netmon ships with selection of built in reports which can be customized and
96. nches of the MIB tree with Netmon s built in MIB Browser See Browsing SNMP MIBs for more information When you find an OID of interest in the MIB Browser you can click the Add Tracker link next to it to have Netmon watch that object at any desired interval Creating an OID Tracker Netmon allows you to track virtually any OID management point on the MIB tree OIDs can contain different types of data The most common data types are CHAPTER 6 MONITORING DEVICES 43 e Integer Example 125658 e Counter Example 40002 e Gauge Example 55 e String Example HP LaserJet 4600DN When tracking OIDs Netmon renders Integer Counter and Gauge data types in a similar fashion Text data types are displayed as a small datagrid When you find an OID of interest in the MIB Browser you can click the Add Tracker link next to it to have Netmon watch that object at any desired interval You will then be prompted to enter the following information Label Apply a descriptive label to this OID Tracker Netmon will suggest a label based on the OID you have selected but it can often be beneficial to add additional information here This label is the main descriptive field used for Netmon s email and pager alerts Sample Every The number of seconds between successive polls Be sure to choose an appropriate value here Enable Logging When this box is checked it tells Netmon to record all historical poll results for the specified OID Tracker
97. nd port scanning service which probes hosts on your various network range s for open ports Netmon scans each host on your network range s every 2 hours and records the results of its scan to the database A port scan report shows all scanned hosts along with the open ports for each host To get more detail on a particular port protocol just click on it Configuring Network Service Alerts Netmon can notify you when it detects a new network service i e open port that was not identified on a previous scan To configure alerting options for this service click the Configure Alerts button at the top of the Port Scan Report output window Panel Actions al Print an instant printer friendly report by clicking this button in the Port Scan Report window Alert History Report The Alert History Report displays a list of all email and pager alerts which have been generated across the entire Netmon system for the specified period of time To run an Alert History Report simply click the Alert History Report link in the Netmon Report Explorer and take the following steps 1 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a date and time range 2 Click the Generate Report button CHAPTER 11 NETMON REPORTS 65 Panel Actions Bi Print an instant printer friendly report by clicking this button in the Alert History Report window Netmon Login Report
98. o monitor the network itself Many monitoring and management systems use the SNMP protocol exclusively to gather information about the network but if this is the only way you are monitoring then you re likely to be missing out on the big picture Think about it In most cases you will probably value the integrity of your entire network over that of any individual host SNMP is great to gather data about devices but in these situations you just can t beat a packet sniffer to get a real understanding of your network s actual state Nevertheless SNMP plays an important role in an overall network monitoring strategy Netmon is capable of retrieving traffic related information from a wide variety of SNMP capable devices and the nice part is that it can grab data for each distinct network interface This is especially helpful for switches firewalls and routers where you ll want to monitor traffic levels across each physical port To work with this information you ll need to take two steps To gather SNMP traffic data from your device first enable SNMP on your managed device and configure it to allow SNMP read or polling operations This process varies greatly by manufacturer Some devices like switches and routers may need to be configured through a command line interface while other devices such as printers and other multifunction products may provide a nice slick web interface Be sure to specify a strong community string pass phra
99. on its title bar to expand it Caution Be careful when scanning hosts that don t belong to you Probing a remote network with a port scanning tool is often considered a form of intrusion attempt Types of Port Scan You can run up to 3 different types of scan with this tool Standard Scan This mode scans several hundred well known ports This type of scan is probably the best choice for everyday audits where an administrator s biggest concern is typically focused toward the exposure of common services like FTP HTTP or file and printer sharing To run a standard scan simply select this option in the Port Scan Panel and click the Scan button to begin Standard scans against non firewalled hosts should be complete in under 10 seconds while a scan against a firewalled host may take a minute or more Complete Scan This mode scans all 65 535 possible ports It takes longer to run a complete scan especially against a firewalled host so generally it is best used when you suspect that a particular host may have been compromised by intruders viruses and or other types of malware or if you have concerns that non standard services may be exposed To run a complete scan simply select this option in the Port Scan Panel and click the Scan button to begin You ll receive a warning Custom Scan This mode scans a host for a user specified port or port range This type of scan is most useful when you are looking for something very specific To scan a sing
100. option in the SYSLOG Explorer window 2 Click the Add New SYSLOG Client button in the Manage SYSLOG Clients window 3 Enter the necessary information in each field as detailed below and then click the Add Now button Netmon requires the following information IP The IP address of the SYSLOG client Facility The message facility to collect This option defaults to any or all facilities Min Severity The minimum message severity level that Netmon should collect Netmon will ignore all SYSLOG messages which fall beneath this severity threshold Browsing SYSLOG Data in Netmon You can look for specific kinds of log messages easily with Netmon s Event Log Explorer You can choose any of these three options Browse by Client Using this option you can browse log messages sorted by each SYSLOG client device Browse by Severity With this option you browse SYSLOG data from any one of 8 different severity levels INFO DEBUG NOTICE WARNING ERROR ALERT CRITICAL EMERGENCY Browse by Facility This option allows you to search by a wide variety of message facilities including KERN USER MAIL DAEMON AUTH SYSLOG LPR NEWS UUCP CRON AUTHPRIV FTP NTP LOGAUDIT LOGALERT and LOCALO through LOCAL7 Monitoring Windows Event Logs Netmon can monitor Event Logs on Windows systems and collect these logs in the same way that SYSLOG messages are handled The same alerting and reporting facilities are also available A software agent is re
101. optional 4 Choose the network interface from which to capture packet data You can choose any physical interface which has been detected on your system 5 Click the Begin Capture button to start the capture Depending on the size of the capture it may take some time to become available for download in the File Manager DNS Lookup Tool The DNS lookup Tool provides a quick method to perform a DNS record lookup for a particular hostname or IP address Traceroute Tool The Traceroute Tool is a handy tool that evaluates the performance of each network hop between the Netmon server appliance and a target host IP address 1Ethereal now known as Wireshark is a free open source progocol analysis package It is the world s mode popular tool for this purpoe Download a free copy of Wireshark at www wireshark org 2Some ISPs carriers filter the network traffic which is used to support traceroute activity In these situations attempts to perform a traceroute will fail at the gateway to that carrier Chapter 5 Monitoring Network Services A Netmon system can monitor the availability and network performance of virtually any TCP IP connected device or service which is capable of responding to network requests How Netmon Monitors Devices and Services If you simply want to determine if a host is alive or not Netmon will use an ICMP PING request to establish the status of the target device If a PING fails Netmon triggers any alerts w
102. oring interval in seconds Monitoring too frequently can generate unnecessary traffic so try to balance polling intervals with your response needs A monitoring interval of 60 seconds often a good choice for non critical devices and an interval of 20 seconds is optimal for mission critical devices 8 Timeout The timeout is the amount of time Netmon will wait for an unresponsive service before queuing an alert in minutes 9 Logging Threshold Choose the type of historical data Netmon By default Netmon will only log entries to the database when it detects that the device or service is DOWN You can however choose various levels of logging verbosity from Disable Logging all the way to Log Everything 1 10 Once you have entered all of the required information click the Add Tracker button to add the service or device to Netmon s monitoring database 11 Netmon begins monitoring your new device or service within about 10 seconds after adding it Attaching Alerts to a PING or TCP Service Tracker You can attach any number of email and pager alerts to a service or device tracker To configure alerts for a particular tracker click the Alerts link in the appropriate row in the Trackers Explorer This opens the Alerts management panel on the right side of the screen When monitoring services you have the option of being notified when the service goes down entirely or when network latency for that service crosses a certain threshold such as 200
103. orts 76 to 100 Ports 101 to 150 Ports 151 to 250 Ports 251 to 500 Ports 501 to 1000 Ports 1001 to 5000 Ports 5001 to 65535 LOU E Print an instant Quick Report by clicking this button in the Port Scan Panel Panel Host Name s Using this panel you can manage Netmon s name database which contains a variety of NetBIOS DNS and User Defined host names Each of these host names maps to an IP address and often many different host names map to the same IP address This console allows you to manage names for any host and even to include your own User Defined labels as well as search Netmon s database for host names which match a particular search criteria Searching for Hostnames To search Netmon s name database enter a search string in the Search Text IP Address box on the Hostname Management console For example to search for all hostnames which contain the text google simply enter google into the Search Text IP Address box Then click the Search button If you wish you can customize your search to NetBIOS names only DNS names only HTTP Requests only or User Defined Names only Removing A Host Name In some cases a host name may no longer be accurate or relevant In these cases you ll want to trim Netmon s name database by deleting inaccurate or outdated names To delete any name simply click the Delete link in the Actions column beside the particular name which
104. ose Custom you will need to enter a valid date and time range 3 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the Disk Activity Report window Email Traffic Inspection The Email Traffic Inspection Report provides details on non encrypted email traffic across a monitored network For each email that matches the filter critera a line showing the sender recipient and subject is displayed Further details for individual messages can be revealed by clicking the link labelled Show on a particular line This will reveal full details about the email message client and server IP attachments message size and headers CHAPTER 11 NETMON REPORTS 62 In order to run Email Traffic Inspection Reports you must enable the IMAP POP3 and SMTP plugins for your sniffing interface in Settings gt Netmon Services To run an Email Traffic Report click Reports gt Email Traffic Inspection and take the following steps 1 Choose a host filter from the Host s dropdown or leave the default selection of all hosts This will limit the results to a particular set of servers or clients if you have previously defined them as filter collections Find more information on filter collections in Administration and Management 2 Select a results limit The Limit Results dropdown allows you to select how many rows of results you will see By default the report will return the top
105. ose Custom you will need to enter a valid date and time range 4 Click the Generate Report button Panel Actions El Print an instant printer friendly report by clicking this button in the Bandwidth Activity Report window Bandwidth Consumption Report The Bandwidth Consumption Report allows you to measure total network activity for particular subnet s or IP range s This report is useful to identify the largest bandwidth consumers and providers on a particular monitored network Before you run a Bandwidth Consumption Report familiarize yourself with the following report parameters Source Network s This is the subnet or IP range you wish to measure Every IP address in the selected range will be accounted for in the resulting report assuming there is network activity for that address Network s to Exclude Any activity between the source network s and the network s specified here is excluded from the reporting result This feature is useful for example if you want to measure Internet bound bandwidth for a subnet while filtering out any local activities i e activity which is switched internally inside the network border Or you may wish to filter out traffic which is destined to a particular branch office CHAPTER 11 NETMON REPORTS 61 Traffic Filter You can use traffic filters to limit the report result to a specific protocol or group of protocols by making a selection here The default selection includes all network activ
106. quired to facilitate this task Considerations for Event Log Monitoring SYSLOG is a push oriented format so most systems that support it are capable of sending log data to a monitoring system with a few small configuration changes Windows Event Logs on the other hand were not designed to be forwarded to other systems but are instead are stored only locally in the file system An agent is therefore required to retrieve these logs and perform the task of sending them to a remote system Using the SNARE Windows Agent Netmon recommends and distributes with all Netmon products on CD ROM the SNARE for Windows Agent which gathers Event Log data and sends it in a SYSLOG compatible format to your Netmon system CHAPTER 8 MONITORING SYSLOG AND EVENT LOGS 50 The SNARE Windows Agent is highly respected open source package which has no licensing costs so you can deploy it on as many systems as you desire and is also supported by Netmon technical staff Netmon can provide you with a copy of SNARE Agent for Windows at no charge t Contact technical support for more information Searching the Log Repository Netmon provides several quick search options in the Event Log Explorer but there are times when you want to perform more finely grained searches of your log repository Using the Event Log Search panel located on the rightmost side of the Event Log console you can search the log repository by any or all of the following paramete
107. re SNMP Auto Discovery form will appear This form allows you to identify your SNMP settings In the Community String field enter a comma separated list of community strings that are in use in your network In the Scanning port field enter the port used for SNMP by your network devices In the SNMP Version dropdown select the version of SNMP which you would like to use on your network Once you have selected the appropriate values click Next Step to proceed to the final form Network Diagnostics The Network Diagnostics form will process then present you with a couple of important diagnostic messages A sample of network traffic will be taken to determine whether port mirroring is configured on your network and the wizard will ensure that the Netmon Update Service is reachable from your Netmon device Review all status messages and close the wizard with the Close Wizard button when finished Your installation is now complete You are ready to move onto the next section Chapter 3 Getting Started Once your server has been physically installed and basic setup has been completed you are ready to log into the Netmon application Logging Into the Netmon Application To log in simply type Netmon s IP address into a web browser which can access that IP address like this http netmon_ip_address This will display the Netmon login screen as follows 12 CHAPTER 3 GETTING STARTED 13 Licensed
108. recognizes the port it will apply a friendly label from its database see Port Label Database In addition Netmon contains a built in protocol dictionary which provides detailed information for a wide variety of protocols To learn more about these ports and protocols you can click the label for additional information which is displayed in the Help amp Resources Panel Speed The average speed over the last 60 seconds of the data stream Other Tips Alternatively you can use Active Connections Panel automatically i e without having to manually enter the IP address through the Visual Network Explorer VNE To do this simply locate the host you wish to explore in the VNE and double click on it This causes the View Active Connections IP address of the host that was clicked to appear in the VNE toolbar Then simply click the View Active Connections button see illustration at left to automatically open the Active Connections panel for the selected host CHAPTER 4 MONITORING NETWORK ACTIVITY 26 Panel Actions El Print an instant Quick Report by clicking this button in the panel Panel Port Scan Using Netmon s Port Scanning Tool With this tool you can scan any IP address to see which TCP ports are open and accepting requests To scan a host simply enter its IP address in the IP Address field of the Port Scan panel Then click the Scan button to begin the scanning process If the Port Scan Panel is not visible click
109. ring vary from manufacturer to manufacturer so consult the product documentation for your switch to determine the necessary steps For Cisco devices the manufacturer has provided an excellent resource to get you up to speed on the SPAN capabilities of Cisco devices and the configuration steps that are required in this document If you are using a hub no configuration is necessary hubs send all traffic to each port automatically Once you have traffic forwarding working on your switch you must plug your Netmon device into the forwarding port on your switch The recommended configuration is to have NIC 1 which the operating system calls eth0 configured as the Management Interface and NIC 2 which the operating system calls eth1 as the Sniffing Interface This means that the Management Interface will be connected to a normal port on your switch for normal network access and the Sniffing Interface will be plugged into the mirrored port on your switch so it can sniff network traffic To accomplish this configure your interfaces as described below Open the Network Admin icon on the desktop On eth0 set the IP Address Netmask and Gateway On eth1 set the IP Address and Netmask but leave the gateway blank Save your changes and reboot the Netmon Server Open the Netmon application in your web browser and go to Settings gt Netmon Services Set the IP HTTP and eth plugins to automatic You can verify that Netmon is properly sniffing tr
110. rld to perform its many monitoring tasks The Netmon Services Manager lets you monitor and manage each of these services for your Netmon server appliance CHAPTER 13 ADMINISTRATION AND MANAGEMENT 79 Starting and Stopping Services Each of Netmon s background services can be started or stopped using this console Under normal operating conditions it is generally not be necessary to start or stop any of these services However if you wish to customize various services for different deployment scenarios or if your Netmon server appliance is behaving unexpectedly this panel can be a quick way to tell if Netmon s core services are alive and running Services that are running are denoted with a icon and services which are off have a icon To change the start stop status of any service simply click the Start Service or Stop Service button next to the service you wish to modify Note that changes made in this panel are not preserved after reboot so they will need to be made again if you need to restart your Netmon server appliance Overview of Individual Services ARP Probe Service Analyzes ARP packets and records MAC IP pairs This service is used to support new host detection in the Recently Discovered Hosts panel on the Netmon Home Dashboard Background Port Scanning Service With this service enabled Netmon performs regular port scans all of the IP address ranges defined in your Local Network range s Email Alert Service This se
111. rom the rest of the network Since it would be unable to reach any of the services and devices it is monitoring it might incorrectly assume that all of those services and devices were down and trigger the appropriate email and pager alerts Nobody wants to receive an avalanche of alert emails and or pager beeps False alerts can be prevented with the use of a Conditional which is simply an IP address that Netmon checks in order to ensure that an alert situation is genuine Tf the IP address specified in the Conditional is determined to be alive through a simple ICMP PING echo request Netmon knows that the alert situation is real On the other hand if the IP address specified in your Conditional is unresponsive Netmon withholds the alert since this would indicate that Netmon itself had a connectivity problem Are Conditionals Mandatory No Conditionals are optional and you do not have to specify any Their use is recommended only to prevent unwanted false alarm situations CHAPTER 13 ADMINISTRATION AND MANAGEMENT 70 Using Conditionals Effectively In most cases you only need to set up two conditionals one which tests internal connectivity such as the IP address of a domain controller or other high uptime device and another which tests external connectivity For external connectivity tests choose the IP address of a highly available web destination such as Google com Adding an Alert Conditional To add a new conditional
112. rs e A specific time range to a granularity of 1 minute e A specific facility or group of facilities A specific severity or group of severities A specific host or group of hosts A specific text pattern or regular expression pattern Configuring Log Alerts Netmon can alert you when a particular type of log message is collected by the system You can be notified when specific types severities or payloads appear in a log entry Netmon can even perform sophisticated pattern matches on incoming log messages through built in support for regular expressions To set up an Event Log Alert take the following steps 1 Click the Manage Syslog Clients link in the Event Log Explorer window 2 Locate the client you wish to monitor for incoming alerts and click the Alerts link next to it 3 Choose the appropriate matches to associate with the incoming alert In the Text Regex field you can enter a text string for basic patter matches or a regular expression for advanced matching 4 Click the Add New Alert button 1Per the License Agreement we can also supply you with a copy of the source code Regular expression are created using a powerful expression language which is capable or preforming very sophisticated text pattern search matching A discussion of regular expressions is unfortunately outside the scope of this text For an introduction to regular expressions visit www regular expressions info Chapter 9
113. rs console In most cases this service should be left running SNMP AutoDiscovery Service This service scans your Local Network range s for SNMP capable devices and tries to connect to those devices If Netmon discovers an SNMP capable device it adds it to a list of discovered hosts in the SNMP console SNMP Interface Monitor This service monitors and records bandwidth utilization for network inter faces on SNMP capable devices SNMP OID Tracker Service This service is responsible for monitoring user defined management points on SNMP capable devices If you are not monitoring custom Object TDentifiers OIDs you can disable this service SNMP Trap Handler This service processes and stores SNMP trap messages and optionally hooks into Netmon s email and pager alert system CHAPTER 13 ADMINISTRATION AND MANAGEMENT 80 SYSLOG Server Starts and stops Netmon s built in SYSLOG server If you are not using the SYSLOG server console you can safely stop this service UNIX Partition Monitoring Service This service is responsible for monitoring Linux UNIX disks and partitions If you are not monitoring Linux or UNIX partitions you can disable this service URL Monitoring Service This service is responsible for monitoring websites and web applications If you are not monitoring these systems you can disable this service Windows Share Monitoring Service This service is responsible for monitoring Windows NT 2000 XP shared folders and dis
114. rts into a single filter Netmon ships with a series of built in traffic filters but you can also create your own traffic filters in the Settings gt Filter Collections gt Traffic Filters console Host Filters Host filters permit you to create logical groups of hosts and narrow your search to a specific IP address or a group of related IP addresses You can assign a friendly name to this group Netmon does not ship with any predefined host filters as these are dependent on the IP addresses which are important to you You can create your own host filters in the Settings gt Filter Collections gt Host Filters console Managing Network Ranges For reporting and automatic discovery services Netmon needs to know the IP range s that belong to you In many cases your network range s will be LAN addresses which use non routable IP ranges such as 192 168 xxx xxx or 10 xxx xxx xxx however this does not necessarily have to be the case When monitoring a WAN for example remote IP ranges could be listed here Each range should consist of a block of addresses such as e 10 10 1 1 to 10 10 1 255 or e 10 10 2 1 to 10 10 3 100 Adding a New Network Range To add a new IP range to Netmon s database press the Add New Network Range button under Settings gt Define Network Range s which makes an editing window visible Enter the following values in the boxes provided Starting Address The starting IP address of a contiguous block
115. rvice supports the forwarding of email alerts to your mail server IP Packet Analyzer Master Process This is Netmon s primary network traffic inspection and protocol analysis service The IP is a misnomer this service is responsible for analyzing network activity at many different OSI layers This service coordinates each instance of a packet analyzer plugin see Packet Analyzer Plugin below allowing incoming data from each interface to be properly managed Packet Analyzer Plugins Interfaces 0 to 3 These plugins examine particular types of network traffic For example the mod_eth plugin examines Layer 2 frame activity while the mod_http plugin looks specifically for HTTP requests at Layer 7 Simply start the desired plugin for each physical interface which is to be monitored for that type of activity Name Resolution Service Responsible for resolving DNS and NetBIOS names for hosts which appear in Netmon s protocol analyzers This service is generally best left active unless you have specific reasons for not resolving DNS names NetFlow Collector This service analyzes incoming NetFlow datagrams and processes them according to the rules and policies set forth in the Devices section and the service configuration settings Pager Alert Service This service manages Netmon pager alert system If you are not using pager alerts you can safely stop this service Service Monitor This service handles ICMP and TCP Trackers in the Netmon Tracke
116. rvices Netmon Engine e Application Middleware e User Interface and Documentation The Netmon Update Service uses the RSYNC protocol to communicate with the update server at Netmon headquarters It therefore requires your Netmon server appliance to establish outbound connections on TCP Port 873 If your firewall rules do not permit this type of connection you ll need to install updates manually from CD ROM Checking for Updates Manually You can also force Netmon to check for new updates anytime outside of its normal 24 hour interval For example you may be instructed by Netmon Technical Support personnel to request an update or you may wish to apply a new update ahead of schedule To manually trigger an update request take the following steps 1 Click the Settings button in the top toolbar 2 Choose Netmon Update Service from the Settings Explorer tree 3 Click the Check for New Updates Now button CHAPTER 13 ADMINISTRATION AND MANAGEMENT 78 Installing Updates from CD ROM If your network does not permit outbound connections on TCP Port 873 you will need to apply patches and updates manually from a CD ROM image which is available at the following location Link http www netmon ca support downloads Managing the Port Label Database When Netmon recognizes a particular port i e TCP port 80 it applies a friendly label i e HTTP from this table Netmon ships with nearly 2 000 built in port labels To manage the port la
117. s and Custom If you choose Custom you will need to enter a valid date and time range 4 Choose the type of TCP IP traffic to scan You can scan for All Activity or you can narrow your search by applying a traffic filter or specifying an individual protocol port combination 5 Finally you can limit your result set and choose the ordering of the information with the Limit Results To and Order Results By selection boxes 6 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the Conversation Report window Web Traffic Report The Web Traffic Report allows you to query Netmon s HTTP Request Plugin which keeps track of URLs which have been requested from your network To run a Web Traffic Report simply click the Web Traffic Report icon in the Netmon Report Explorer and take the following steps 1 Choose a host or group of hosts to include in your query and make the selection in the Hosts selection boxes You can run a Web Traffic report against All Hosts in the database or you can narrow your search by applying a host filter or specifying an individual host to scan 2 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 3 Enter a keyword or partial text string to narrow your search if desired This field is optional 4 Click the Generate Report bu
118. se this service to monitor your corporate website company intranet or any other web based system Introducing the URL Tracking Service Netmon requests a user specified URL at user configurable intervals It receives the resulting HTML web page or XML or any other HTTP payload and inspects the contents for a user specified text pattern If Netmon finds a matching copy of the text pattern or phrase in the response it assumes the website or web application is functioning normally If Netmon does not find a matching string in the response content it can be configured to queue an alert message Creating a New URL Tracker To create a new URL Tracker take the following steps 1 Click the Trackers button in the top toolbar followed by the URL Trackers button 2 Click the Add New URL Tracker button 3 Specify the desired URL in the URL text box If you wish to include additional GET parameters ap pend them to the end of the URL in the usual querystring format i e http www someweb com somescript php varl true zx 4 Specify a text Pattern to use when matching the incoming HTTP response You can specify a simple text string or use a Regular Expression PCRE for more sophisticated matching capabilities 5 Choose a monitoring interval in seconds In most cases the 5 minute 300 second interval is suitable 6 Click the Create Tracker button Attaching Alerts to a URL Tracker Netmon can alert you by email or pager when it detects a
119. se wherever possible The second step is to add your SNMP device in Netmon s SNMP Device Explorer You ll have to supply your device s community string to Netmon Once you have added your device the Netmon SNMP Service will begin polling that device for information For additional configuration information see the Netmon User Guide Once these steps are completed you should start to see SNMP traffic data within a few minutes Netmon s SNMP viewing tools allow you to easily spot trends and spikes for each distinct device interface and you can historical charts and graphs as well Using the SNMP Automatic Discovery Service The simplest and easiest way to add new SNMP capable devices to your Netmon server appliance is to let Netmon do most of the work for you In most cases Netmon can identify a large number of SNMP capable devices automatically in just a few minutes The SNMP Auto Discovery service scans your local network range s for SNMPv2 capable devices and attempts to connect to them with the default community string public If a successful connection is made Netmon automatically adds the device to your Device Explorer collection Devices which have been discovered in this fashion have a icon next to them in the Device Explorer tree CHAPTER 6 MONITORING DEVICES 35 Using a Different Community String Netmon s automatic discovery service can be configured to use any community string you wish To make changes to the community
120. select Alert Conditionals from the Settings Explorer and click the Add New Conditional button A dialog window opens in the Settings Editor panel on the right side of the screen Enter the IP address of the conditional in the IP Address and specify a friendly name in the Conditional Name field To add this conditional to the database press the Add Conditional button when you have finished entering the preceding information Removing an Alert Conditional To remove an alert conditional from Netmon s database select Alert Conditionals from the Settings Explorer and click the Delete link next to the conditional you wish to remove You ll be prompted to confirm your decision click OK to proceed with removal of the selected conditional or Cancel to abort the operation If you remove a conditional you will also remove that conditional from any previously configured alerts Other previously configured conditionals for existing alerts will remain unchanged Managing User Accounts Each individual who uses Netmon should have an individual user account These people might include network administrators system technicians or even management administrative personnel Logging in with Netmon s admin account for normal everyday system usage is not recommended Viewing Account Details To quickly view expanded details for a user account such as group membership or pager information click the Details link in the Actions column next to the desired
121. site You can also refer to HP s Linux Capabilities Matrix Some equipment may require HP specific drivers not part of the normal Debian distribution which will require you to perform a manual Netmon SE installation CHAPTER 1 HARDWARE SUPPORT IN NETMON SE 6 Dell Dell does not officially support Debian on its hardware but it does provide some guidance for the installation of Debian on it s PowerEdge 9G servers For details refer to the Dell Debian support page Keep in mind that Netmon SE uses only drivers bundled with Debian 4 0 Though it may be possible to use third party drivers provided by Dell or otherwise to get Netmon SE running this would be an unsupported installation Problem Hardware Hardware on this list has been reported to cause problems with Netmon SE Network Devices e D Link DGE 500T This device uses the National Semiconductor DP83820 chipset This devices appears to have driver issues that render it unusable under the version of Debian Linux used in Netmon SE e Broadcom 5700 This device is not supported by Debian Linux Community Support There are a number of resources maintained by the community around Debian and the wider Linux commu nity that may help clarify the driver support situation for your particular hardware Netmon Inc has no connection with these sources of information and can not guarantee their accuracy or applicability to Netmon SE They are listed here as a convenience e Debi
122. specially ones which are already under a heavy workload What is a MIB A Management Information Base MIB generally defines the set of parameters that an SNMP management station can query or set in in an SNMP enabled device It is essentially a collection or more than one of information that can be gathered from an SNMP enabled device Common MIB Data Types Netmon automatically recognizes the following common MIB data types 32 Bit Any 32 bit value This value is generally expressed as an integer Gauge Any 32 bit value This value is generally expressed as an integer Hex A 32 bit hexadecimal number Integer Any valid integer Host Address An IP address OID A numeric OID reference string String A string value Timeticks usually expressed in milliseconds or microseconds Managing Custom SNMP MIBs Netmon permits the uploading of custom MIBs to its repository Once imported OIDs specific in the MIB definition will be replaced with the translated human friendly representations Uploading a Custom MIB To upload a custom MIB click the Manage Custom MIBs button at the bottom of the SNMP Device Explorer panel This opens the MIB File Manager in the middle pane Click the Upload New MIB button which opens the SNMP Manager window in the rightmost panel Click the Browse button to locate the MIB file on your local system Once you have selected a file click the Upload button to import it into Netmon
123. strators group nor should you delete all groups Doing so could result in an unexpected lockout from administrative functions Managing Alerts Netmon has a central facility for managing alerts from all sections of the application Navigate to Settings gt Manage Alerts to see a list of all configured alerts Each alert is listed in its own information box At the top of the information box the alert type is listed in blue along with the alert description The alert s configuration is fully detailed in the lines below Along the top of the Alert Management interface are three buttons Pause Selected Resume Selected and Delete Selected These buttons work in conjunction with the checkboxes next to each listed alert and the Toggle all checkboxes checkbox Using the checkboxes select the alerts you would like to take immediate action on and click the appropriate button You can take the same actions against a single alert by clicking the Delete or Pause Resume links on the right hand side of the alert s information box To modify an existing alert click the Edit link to open the Settings Editor for this alert Here you can modify the alert s conditions descriptions or recipients When finished click Update Alert to save your changes To create a maintenance window for a specific alert click the Schedule Maintenance link in the alert s information box The Settings Editor will now show the Maintenance Schedule Builder Use this inter
124. string used by the SNMP Auto Discovery service take the following steps 1 Click Settings gt Netmon Services 2 Locate the SNMP Autodiscovery service in the list and click the Configure link next to it 3 Enter your custom community string in the community text box and then click the Update button next to it 4 Click Settings gt Netmon Services again 5 Locate the SNMP Autodiscovery service in the list then stop it using the Stop Service button When the page reloads click the Start Service button This will restart the SNMP Autodiscovery Service using your new Community string Using the Devices Explorer Netmon displays all SNMP devices in a tree format in the Device Explorer You can reach the Devices console by clicking the Devices button in the top toolbar ea eet Within the Device Explorer you can create groups of devices for orga ai new Group 8 new Device miss 7 nizational purposes These groups can be manipulated through drag and a qwindows Devices winlab 10 10 1 23 drop and via the buttons at the top of the Device Explorer interface saw EA To create a new group in the Device Explorer click the New Group aus 10 10 1 101 a a EM Microsoft SQL 2005 10 10 1 139 button A new group will appear in the device explorer with the empty Device Dashboard group icon and the label of the group will filled in with the text New a spa Lr etwork Interfaces Group
125. t the appropriate fields outlined below and click the Create Command button Label A friendly name or label for this command Command The actual command syntax The text specified here is run as a shell command on the Netmon server You can use the Insert Variable buttons on the top of the Alert Template window to insert dynamically changing values i e the device IP address hostname etc into your command string Netmon will substitute these values for each individual alert Timeout The number of seconds Netmon should wait to run the command before giving up Process Asynchronously Add Output To Alert You can choose to process the command before the alert message is sent by selecting the Add Output to Alert radio box In this case Netmon will append the results of the command to the alert message you receive Alternatively you can run the command separately CHAPTER 13 ADMINISTRATION AND MANAGEMENT 74 from the alert message by selecting the Process Asynchronously radio box so that the command and alert message are both processed separately from one another Modifying an Existing Alert Command Any existing commands will be listed in the Alert Template editing window To modify an existing command simply click the Edit link next to it Make any necessary adjustments and then click the Update Command button Removing an Alert Command To remove a command from the available selections simply click the Del link next to it You ll
126. template Restoring Default Templates To restore any template to its factory default settings select it from the template list and click the Restore Default Template button The window contents will be immediately populated with the factory default alert message for that particular alert You must then click the Save Template button to commit any changes to Netmon s database Managing Alert Response Commands Netmon can run special scripts or commands in response to an alert event For example you may wish to run a port scan against a newly discovered host or receive a list of large files when a disk capacity alert is issued Using this facility you can also issue a restart to an unresponsive Windows service Alert commands are associated with alert events and they are managed on the same screen as Managing Alert Templates Once a command has been associated to a particular alert event you then have the option to run that com mand for any alerts of that type Note that alert commands do not run automatically in response to alert events You must still associate any desired commands you wish to run with each new alert you create This area simply allows you configure which commands are available for a specified alert type Creating a New Alert Command To create a new alert command take the following steps 1 Click Settings gt Alert Message Templates and locate the alert condition to which you wish to attach a new command 2 Fill ou
127. the interface measured in bits per second bps MAC Address If Netmon is able to resolve the MAC address of the interface it is displayed here Otherwise you ll see the text Unresolved Technical Note To attain the MAC address of a port first Netmon determines if the device is a Cisco switch or not If so it first acquires a list of operational VLANs using CISCO VTP MIB vtpVlanState 1 3 6 1 4 1 9 9 46 1 3 1 1 2 It then uses each VLAN index in this list to query BRIDGE MIB dot1dTpFdbPort 1 3 6 1 2 1 17 4 3 1 2 using a community string composed of community VLAN_INDEX to obtain a listing of MAC addresses and virtual ports It uses the virtual port number to query BRIDGE MIB dot1dBasePortIfIndex 1 3 6 1 2 1 17 1 4 1 2 which returns a physical port number If the device is not a Cisco switch it skips the step of querying the VLAN states CHAPTER 6 MONITORING DEVICES 39 Connected IP MAC If Netmon is able to determine the IP or MAC address of the host that is connected to this interface it is displayed here Otherwise you will see Unresolved Label This is the interface s friendly label By default Netmon displays the label provided by the SNMP host However you can override this label by typing your own text into the textbox and clicking the Update button Display on Home Page This checkbox allows you to show recent activity for this interface on your Netmon home page For example you may want to display all of your outsid
128. this panel you can B Access the Netmon User Guide Stay up to date on recent network security news with the Security amp Monitoring News Center CHAPTER 3 GETTING STARTED 18 E Request technical support through either the Live Chat system or by sending a message through the built in Support Request Form e Learn more about specific parts of the Netmon application with context sensitive buttons located throughout the Netmon user interface Other Panel Actions 3 E o a gt As you move between different pages in the Help amp Resources panel these buttons can help you navigate El All of the pages which are displayed in the Help amp Resources panel are automatically printer friendly Just click this button for a perfect printed document Chapter 4 Monitoring Network Activity How Netmon Monitors Network Traffic One of Netmon s core strengths is the ability to monitor and analyze different types of local and remote network traffic at a highly detailed level Netmon can monitor network activity using any of the following facilities Method 1 Packet Protocol Analyzer The Netmon server appliance captures and analyzes all network traffic which passes across its network card s It is most commonly connected directly to a hub or a switch which has been configured to forward a mirrored copy of all the frames traversing that device In these configurations Netmon receives a copy of the pack
129. tmon Column Definitions Name Type Description srv_id int8 available int4 total int4 timestamp int4 status int4 threshold int4 interval int4 timeout int4 port int4 ip inet pending varchar message varchar servername varchar partition varchar partition name ie dev sda fs_directories Table Overview This table contains a list of directories which should be included in Netmon s Files Explorer Column Definitions Name Type Description id int4 notes text permissions _varchar real_path varchar label varchar Label for this directory 91 CHAPTER 15 DATABASE REFERENCE 92 fs_files Table Overview This table contains a list of files which are currently available in the FILES console Column Definitions Name Type Description busy bool directory_id int4 id int4 description text filename varchar label varchar Label for this file groups Table Overview This table simply specify what user groups are available This can be used as Role Management or simply User Grouping recommended for flexibility Column Definitions Name Type Description id int4 group name varchar Name of the user group hosts Table Overview This is a catalog of hosts that were identified on the network at some point Column Definitions N
130. tton Panel Actions Bi Print an instant printer friendly report by clicking this button in the Web Traffic Report window CHAPTER 11 NETMON REPORTS 60 UP DOWN Time Report This report provides a summary of the availability of each of your monitored services and disks for the time interval specified To run an UP DOWN Time Report simply click the UP DOWN Time Report icon in the Netmon Report Explorer and take the following steps 1 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you choose Custom you will need to enter a valid date and time range 2 Click the Generate Report button Panel Actions Bi Print an instant printer friendly report by clicking this button in the UP DOWN Report window Bandwidth Activity Report A Bandwidth Activity Report plots bandwidth utilization for SNMP device interfaces such as those found on routers firewalls switches and servers for a given time interval Note You can only run a Bandwidth Activity Report if you have enabled historical logging for an interface To run a Bandwidth Activity Report simply click the Bandwidth Activity Report icon in the Netmon Report Explorer and take the following steps 1 Choose a device from the SNMP Device drop down menu 2 Choose an interface for the selected device from the Interface drop down menu 3 Choose a reporting period Available choices are Today Yesterday Last 7 Days and Custom If you cho
131. uctural topology of your network The devices on your network are automatically discovered by the mapper which then identifies as many attributes about the device as possible through a variety of means For example if you are monitoring a device with SNMP the mapper component uses that information to select an icon for the device In addition to discovering device attributes the mapper component also tries to discover the relationship between devices on the network When the mapper discovers a switch on your network it will attempt to identify all the connected devices and attach them to the switch on the map Mapper basics The mapper is unique among Netmon components in that it opens in its own window or tab in some browsers This is due to the space requirements of the map itself If your browser blocks pop ups you may have to allow pop ups from your Netmon device s URL before you can see the map The mapper displays an interactive map of your network topology The display is static once loaded so newly discovered devices can only be added by reloading the map component or clicking the Refresh button in the upper left hand corner of the map Working with the map The map has a maximum resolution of 3200 x 3200 pixels Netmon will try to lay out your devices for maximum visibility in the smallest space but you will most likely want to adjust the default layout To move a device click and hold the mouse button down while the
132. use the drop down boxes to start the plugin automatically whenever the Netmon device boots or press the Start Plugin button to start the plugin manually Netmon emits data in NetFlow v5 format In addition to the UDP port specified the target machine must also be able to access the NetFlow emitter device using SNMP and the device must be configured as an SNMP device in the target Netmon device Please review the Netmon documentation for Monitoring Network Activity for full details Using the Visual Network Explorer The Visual Network Explorer VNE component provides a dynamic graphical view of your current network activity on local or remote segment s You can customize this view in many different ways to find information of interest VNE Basics The VNE displays a live interactive graphical map of your current network activity As your network traffic patterns change the display is updated automatically every 20 seconds You can move individual hosts around on the map by clicking and dragging on them You can also move the entire map itself simply click and drag any empty space in the map This is particularly handy when you ve zoomed in to view a single part of the map You can also use the Zoom tool to your advantage if a particular host appears too small or if you simply wish to zoom in for more focus you can click and drag the Zoom slider Zoom ranges from 50 to 250 are provided Don t forget you can click and dr
133. you wish to remove You ll be prompted to confirm that you really do wish to delete this name from CHAPTER 4 MONITORING NETWORK ACTIVITY 28 the database If you re certain click the OK button to proceed and Netmon will remove the name from its database Adding a User Defined Host Name You can apply your own friendly host name to any IP address Click the Add New Host button in the Manage Hostname Database panel An editing window will open in the Settings Editor panel on the right side of the screen Enter the IP address and label then click the Add Hostname button Your IP address will now appear as your friendly label throughout the application Network Tools The Tools panel contains a variety of useful network diagnostic tools Capturing Raw Network Traffic with the Packet Capture Tool Netmon features a low level packet capture utility which can record network activity payload and all for further analysis in a protocol dissector such as Ethereal Wireshark To use the raw packet capture tool take the following steps 1 Click Network gt Tools gt Traffic Capture 2 Choose the number of packets to capture from the available drop down box In most cases it s best to start with smaller captures 100 to 500 packets and progress toward larger ones 1000 or more as necessary 3 Add a label if desired to this capture Labels are used to differentiate between capture files in the File Manager This step is
134. ystem uses xinetd Monitoring a Unix partition requires a minor change to two configuration files on the remote system These files are called etc services and etc inetd conf 1 Insert the following line into etc services df 5001 tcp DF We have specified port 5001 here but you can actually choose any port number you wish However you ll have to remember to specify the same port number when adding this information to Netmon 2 Create the df script in etc xinetd d with the following content service df disable no flags REUSE socket_type stream wait no user root server bin df 3 Restart xinetd with the following command killall HUP inetd Alternatively you can use the following command kill HUP lt inetd PID gt 4 Open the Disk Trackers panel located in the Trackers console 5 Click the Add New Disk button on the Disk Monitoring panel and choose UNIX for disk type 6 Fill in the following fields then click the Add Disk button IP Address This is the IP address of the UNIX host Port Specify the port number to which Netmon must connect This should be the same port number as entered in Step 1 above Partition Enter the device name of the partition i e dev sdal or dev hdal Timeout Specify how long in minutes Netmon should spend trying to connect to the remote host The default timeout period is 5 minutes but this can be set to any interval you choose Interval Specify how frequently

Download Pdf Manuals

image

Related Search

Related Contents

Untitled - medsklep.pl  CH - CBradio.nl  External display from FLARM EDIATec GmbH Installation Manual  Manuel DeltaSol® CS/2  17” LED Surveillance Monitor  Model 100 POX Manual - English: Low Resolution  S Manual de Instrucciones  InSinkErator H-CONTOUR-SS Use and Care Manual  Makita HR2641 Use and Care Manual  Chapitre 8: Geberit AquaClean  