Home
CFX-750 Display User Guide
Contents
1. VRS Status ki r ii a Tirar AH E Fum 4 uraceier Binira Faint WS Leer Hera Sega an IEL ae E ar TWN AG GAGE WU Pessord Copvic em Flere Big Mere Pome s Were VRS connection status Description Logged in VRS connected Connecting Mobile network Searching Disconnected Mobile network No service Connected Farm Setup When you enable the Connected Farm feature this allows the CFX 750 display to use the Connected Farm server to automatically and wirelessly send field information to your home computer Initial setup The Initial Setup wizard takes you through the process of setting up your wireless modem and registering the network By default the Connected Farm feature is set to Off To turn the feature on 1 Tap Connected Farm Setup and then Connected Farm 160 CFX 750 Display User Guide 2 Data 8 Select On The Connected Farm Setup screen appears Connected Farm Setup Note When you turn the Connected Farm option On tapping Connected Farm Setup takes you directly to the Connected Farm Setup screen The following sections describe the menu options available from the Connected Farm Setup screen Device name Use the on screen keypad to give your device a name that you will recognize once you transfer the data to your personal computer Modem only setup Use this option to set up your wireless modem Once you connect your modem the following screen appears Modem Detecte
2. i hi he ir ie PAIE ELLEI LELET J Item Description Notes 1 8 Touch sensitive screen To interact with the system tap the screen with your finger For more information see Recalibrate touchscreen page 177 Speaker You can adjust the speaker volume or turn it off For more information see Touchscreen speaker volume page 170 Integrated lightbar with 27 LEDs When lit the LEDs show the position of your vehicle relative to your intended guidance line For more information see Reading lightbar patterns page 41 CAUTION Do not press on the screen with a sharp item such as a pencil or screwdriver you may damage the surface of the screen 26 CFX 750 Display User Guide Back view 0 0 Description Power button Brightness controls USB socket GPS connector Port A Power connection socket Port B Radio access panel Getting Started 3 Notes Turns the display on or off e To increase the brightness of the screen press e To decrease the brightness press Note You can also use the Color Scheme and Backlight menu options to set the screen brightness See Color Scheme page 169 and Backlight page 170 You can connect a USB memory stick to the display to transfer data to and from the unit For more information see The USB socket page 31 Connects the GPS cable P N 50449 to the display Connects external devices to the display Connects the power cable
3. Select Material Control 90 CFX 750 Display User Guide Options No Material Named materials for example Corn Soy Options Switch Boxes Touchscreen Only Description Select the location name This is the default of a location and means that the location is disabled Select a material to assign it to the location To switch out the material tap the location button in this example Hoppers and select a new material To disable the location select No Material Note If the material you require is not listed exit from this screen and then set it up using the Material Setup procedures See Setting up a Material page 84 Description The location is linked to both the master switch box and the 12 section switch box The location is controlled from the touchscreen Note The CFX 750 display requires the use of a 12 section switch box for section control Implement Application Controller 5 Section Control Setup Control Setup Edit Screen l Section Control Setup l l l Section Control Section Control Section Control Operation Module Operation y Y y y y y m gt On Latency Overlap Coverage Number of Section Controller Section Grouping Allowable Modules x N gt Off Rate Error gt L
4. 0 00 10 00 m CFX 750 Display User Guide 113 5 5 Implement Application Controller Target Rate Set the target application rate that will be sent to the Rawson controller Enter a rate between 0 0 11000 0 Alternatively you can load a prescription so the CFX 750 display will automatically send target rates to the Rawson controller Note When the CFX 750 display is sending target rates to the Rawson controller the Rawson controller will only display the Target Rate screen To change or view any other screen on the Rawson controller you must unplug the CFX 750 display cable Note When using a prescription with the Rawson controller the target rates in the prescription must match the step sizes in the Rawson controller For example if the default is 25000 and the step size is 4 then the target rate values accepted by the Rawson controller are 26000 27000 28000 40000 Otherwise the Rawson controller may not be able to apply the correct rate Default Rate On the CFX 750 display set the same target rate that appears on the Rawson controller when you first power up it up Enter a number between 0 9999000 Step Size The step size increases or decreases the actual applied rate by the percentage that you select You can choose from one of the following settings 2 4 62 Rate Snapping Due to pump constraints liquid flow is generally inconsistent To control how these inconsistencies appear
5. AG25 antenna 77038 AG25 antenna mount plate 62034 18 CFX 750 Display User Guide Installing the Display and Antenna 2 Installing the display Mount the CFX 750 display in the vehicle cab When you position the display make sure that e it is within the driver s reach the USB drive is easy to remove and replace e the touchscreen is easy to see but the display does not block the driver s view e jt does not interfere with the driver getting in or out of the cab or any other activities The image shows the mounting assembly for the display Item Description Oo Diamond shaped mounting plate RAM mount Bar mount To install the display 1 Use the supplied screws to firmly attach the diamond shaped mounting plate to the back of the display CFX 750 Display User Guide 19 2 Installing the Display and Antenna 2 Attach the RAM mount to the ball on the diamond shaped mounting plate a TT PERTE AEN RAA Pa T A LF ae x z ry r oF iF ites ooh i F B 3 Select a position in the cab for the display Hold the display in the selected location and check that it is easily accessible from the driver s seat 4 Use the provided bolts to attach the bar mount to the cab 5 Attach the other end of the RAM mount to the ball on the bar mount and then tighten the screw Connecting the display The diagrams in this section show how to set up the CFX 750 display as a standalone system To
6. From the guidance screen tap to quickly adjust the aggressiveness setting for the EZ Steer or Autopilot system x ay Agresa eee i a Reading lightbar patterns When lit the LEDs show the position of your vehicle relative to your intended guidance line As your vehicle position changes in relation to the guidance line the LEDs move left or right Use the lightbar to obtain accurate guidance when e you have set an implement offset or implement draft fine tuning guidance on straight swaths The LEDs in the integrated lightbar show the position of your vehicle relative to the guidance line e When your vehicle is on the guidance line the three central green LEDs are lit CFX 750 Display User Guide 41 3 Getting Started e As your vehicle moves off the guidance line the lit LEDs move left or right and change to red Note that the LED pattern that appears has a different meaning for each Main Lightbar LED Mode For more information see the table below and Lightbar Setup page 170 This LED pattern Indicates that the vehicle is OONN Ea Direct on the guidance ine OF the guidance line For this pattern if the Main Lightbar LED Mode is set to e Chase the vehicle is offline to the left e Pull the vehicle is offline to the right Ds O the guidance line For this pattern if the Main Lightbar LED Mode is set to e Chase the vehicle is offline to the right e Pull the vehicle is offline to the l
7. If you use the vehicle on a public roadway you must put the red EZ Pilot system override switch in the off position 70 CFX 750 Display User Guide Vehicle 4 The Autopilot automated steering system Note For advanced setup options contact your Trimble reseller Setup To view and adjust settings for the Autopilot system 1 2 In the guidance screen tap P and then tap Vehicle Tap Auto Steer and then tap Autopilot Configuration Auto Steer Note If the Autopilot Configuration button does not appear tap Auto Steer System Type and then select Autopilot for your controller From the Autopilot Configuration screen you can view and adjust the settings for Online Aggressiveness Operator Alert Timeout End of Row Warning Distance NMEA Output See Chapter 7 GPS Save Vehicle Configuration File use a virtual keypad to save your current vehicle configuration Operation You must calibrate and set up the Autopilot automated steering system using AP Toolbox before operation Engaging the system Before you can engage the Autopilot automated steering system you must open a field in the guidance screen define an AB line position the vehicle within the configured engage limits CFX 750 Display User Guide 71 4 Vehicle To engage the system 1 Point the nose of the vehicle toward the guidance line and drive at operational speed 2 Doone of the following From the guidance screen tap
8. L gt Rate Section On Latency Start Overlap Modules gt Restore Details gt Off Latency gt End Overlap Number of gt Section 1 N Switching Overlap Boundary Switch Overlap Select Section Control Section Control oes Lee or Section Control Operation Latency Latency ERA FHRA F FPA Be Fa ror Frem ee Eri EEr E l T a imir Section Control Operation Overlap Overlap E eee ee a Fur nr Options On Off Rate As Section On Latency Off Latency Start Overlap End Overlap Coverage Switch Overlap Boundary Switch Overlap Sections gt Control Type Turn Off When Stopped Description Turn section control on No section control used for this location Use the rate control as section control Note This means that the rate will go to zero and shut down the control in a covered area or non productive zone The length of time that is required before a material is applied when the section is turned on The length of time that is required before a material stops applying once the section is turned off The amount of intentional overlap required when leaving already covered area and going into a non covered section of the field The amount of intentional overlap required when going into a covered area The amount of side to side coverage overlap before a section shuts down The
9. Sprayer Floater Truck e Front axle Awd tractor Combine Swathers Note For swathers it is recommended that you put the antenna directly above the front axle or slight ahead e Track center Tracked tractor If the antenna is e in front of the axle enter a Forward distance e behind the axle enter a Behind distance T3 roll calibration Calibrating the T3 roll sensor enables the display to calibrate terrain compensation in the IMD 600 unit This step requires you to 1 Enter an accurate value for the IMD 600 orientation Controller Orientation a E ata connector aae a fn comer l Fi ma T a l L f E C 2 Park the vehicle and mark the inside of both sets of wheels 3 Remain stationary while the system calculates the roll offset This takes approximately 20 seconds 60 CFX 750 Display User Guide A Vehicle 4 4 Turn the vehicle around and ensure the wheels are over the positions marked in the previous step 5 Remain stationary while the system calculates the roll offset This takes approximately 20 seconds Angle Per Turn calibration You must first set the IMD 600 orientation and perform the T3 terrain compensation calibration You must operate the vehicle in an open field with ample area for the vehicle to make right and left turns 1 Tap Right Angle Per Turn Calibration 2 Drive forward until appears and then tap the icon Note For the best results drive the vehicle
10. When you create a headland you must specify the total number of circuits including the master headland This defines how wide the headland is Note No matter how many circuits you create define only the outside headland The inner headlands are copied from that original circuit Internal pattern The internal pattern is the pattern of the guidance lines inside the headland Choose from the following Choose this pattern To create Straight AB Standard parallel swaths inside a headland A Parallel swaths at a pre defined heading Reselecting the headland When you use the headland pattern you can see either the headland or the internal pattern To see the headland guidance again when you are driving the internal pattern drive into the headland before the first internal swath or after the final internal swath The headland appears automatically 144 _ CFX 750 Display User Guide Mapping and Guidance 6 Mapping a headland 1 Drive to the start point of the headland 2 Tap g to set the start point of the headland 3 Begin to drive the circuit of the headland Note To ensure straight sides on the headland you can use the pause feature See Creating straight sections on Headland or Curve swaths page 136 4 Tap to set the A point of your guidance line If the internal pattern is an A tline the line is set An AB Line continue to drive around the headland When you reach the other end of the int
11. the recipient automatically receives a license from the original licensor to copy distribute link with or modify the Library subject to these terms and conditions You may not impose any further restrictions on the recipients exercise of the rights granted herein You are not responsible for enforcing compliance by third parties with this License Warranty Remedies Trimble s sole liability and your exclusive remedy under the warranties set forth above shall be at Trimble s option to repair or replace any Product that fails to conform to such warranty Nonconforming Product and or issue a cash refund up to the purchase price paid by you for any such Nonconforming Product excluding costs of installation upon your return of the Nonconforming Product to Trimble in accordance with Trimble s product return procedures than in effect Such remedy may include reimbursement of the cost of repairs for damage to third party equipment onto which the Product is installed if such damage is found to be directly caused by the Product as reasonably determined by Trimble following a root cause analysis Warranty Exclusions and Disclaimer These warranties shall be applied only in the event and to the extent that a the Products and Software are properly and correctly installed configured interfaced maintained stored and operated in accordance with Trimble s relevant operator s manual and specifications and b the Products and Softwa
12. 4 Vehicle 7 Route the cables of the footswitch or rocker switch to the required location 66 CFX 750 Display User Guide Vehicle 4 Setting up the display when using a foot or rocket switch 1 Select Settings Vehicle Auto Steer EZ Pilot Setup 2 Tap EZ Pilot External Switch Engage Options Minimum Speed 1 4 mph F Direngage OMine ic or Maximum Speed 162 mph F Override Sonsitivity 19 External Switth Otusbled K Operator Timeout 15 min Tap Remote Engage and then tap wi External Switch The switth engages and disengages Autostar seat Diserepage Seat Engage Only CFX 750 Display User Guide 67 4 Vehicle The Switch functionality now shows Remote Engage and is ready to be used Engage Options fj Cisengage Offling ic ee F Maximum Spad 164 mpi Fj Override Sensitivity m rj External Sw ch Aemets Cagege rj Operator Timeout 15 min Disengaging the system The EZ Pilot system automatically disengages when one of the following happens The vehicle is outside the configured engage limits You pause the system GPS positions are lost You tap the Engage button on the guidance screen You press the Engage button on the optional EZ Remote joystick You can manually disengage the EZ Pilot system by turning the steering wheel this overrides the electric motor Check this setting before you start using the system by engaging on a line and then turning the wheel until
13. CallDVatiON s ac aee oe hehe RGD EES Se HASSSEESES EOE ED eG 51 OPECUN ce khb Gea hae ede beer ak eee ae 54 The EZ Pilot steering system ouaaa a 56 SetUDo es oe 545 ee eee eae ee a eee eee SE ee eee ee Scere ee 56 Calibrati N esa ace bee eee ee ee eee eee ae we 58 Operation Bega etaea ck eeuae wee ew tebe eee BARGES OES Ee Eee 61 The Autopilot automated steering system o oo a a a a a a 71 SCUWDS tee eee ee hee E ee ee eee eRe ee eee eee eee 71 ODGAUON sss ao3 SERRE SEES ESSE E EERE OSH EDGE EO ES 71 5 Implement Application Controller 2 42224 73 I NEGOGUCUION on beau obese utewe eee eeu ee eee ee howe eee Hee es 74 Presciptions ccc pA Ree EHH HRED HERS HER ERERG HERE A Keowee 75 Field IQ crop input control system 1 ee 76 Definitions sss rrsasrriir adari eee EERE Re oe ees 77 Units OF measure o ew EKKO SEE EEE EE DEED EDDY SD DS 77 Installing the Field lIQ hardware 2 ee 78 Setting up the Field lQsystem 2 a 78 OPEIN Gace se tee ee eae RA ee eee ee eee Bea oO Bw es 103 HARDI 5500 controller aoaaa 106 2 a0 EEE a ee ee eee ee eee ee ee 106 Advanced cB Boe RARER EHH SRE HERE RAKE EAE ERASE ww ww a 106 Oje ene 55 64 bb ae ROS ee eee Eee EEG eS ED we Oe ee 108 Raven controllers 24a 4044 FSS ENE SSR EEE M ES OOE SEED EHO wD ER EHS 109 S Enio cara a nm ee ee ee ee 109 Advant sesser CGRES SEER E RHETT REDES ESE HHS ES 110 OBCMAUON 4446 64445 5e ene aww ee eee ee DOS eee eee ee ee eae 111 R
14. and access to various system functions The availability of the text and icons depends on the set up of your system For example some icons are not available while you are using an auto steer system To activate an icon tap it with your finger If the display does not respond when you tap it see Recalibrate touchscreen page 177 The following sections describe the icons that can appear on the guidance screen 34 CFX 750 Display User Guide Status Getting Started 3 Tap a to scroll through several pop up screens that describe various system settings Field Hame 023110 O ee Leverage HU g Fiatiga Hudge imp Width E ELTI map a int aae Settings To remove the pop ups continue to tap E until they disappear Settings Tap P to open the Settings screen Use the Settings screen to adjust your system settings and view the status of the following Chapter 6 Mapping and Guidance page 129 Setting For more information see Vehicle Chapter 4 Vehicle page 47 Implement Chapter 5 Implement Application Controller page 73 Guidance GPS Chapter 7 GPS page 149 Data Chapter 8 Data page 155 Syst em Chapter 9 System page 167 CFX 750 Display User Guide 35 3 Getting Started View The options for viewing the guidance screen are Zoom In Zoom Out Change View this toggles between the Overhead view and Trailing view icons Panning Mode change the view tap y and then select th
15. page 62 Engaging the EZ Pilot system using an external foot or rocker switch To install a foot or rocker switch 1 Locate the foot or momentary rocker switch and the remote engage adapter cable P N 88506 included with the foot switch kit P N 78150 00 or purchased separately 2 Remove the wedge from a receptacle 3 pin Deutsch DTM 62 CFX 750 Display User Guide Vehicle 4 3 Doone of the following Fora foot switch hold the receptacle with the lock facing upward with the black wire on the right hand side the white wire in the middle and the green wire on the left hand side Note If you purchased P N 78150 00 the correct connector is already attached Fora rocker switch insert the wires into the right and middle sockets the orientation does not matter CFX 750 Display User Guide 63 4 Vehicle 4 Re insert the wedge into the receptacle 5 Connect the attached receptacle to the 3 pin DTM plug on the remote engage adapter cable 64 CFX 750 Display User Guide Vehicle 4 6 Plug the other end of the remote engage adapter cable into the port replicator pin 10 and pin 11 on the EZ Pilot cable that is connected to Port B on the CFX 750 display Note If you are using a sonalert you must remove engage pin 10 and move it to pin 8 so that the remote engage functions run between pin 8 and pin 11 and the sonalert functions between pin 2 and pin 10 CFX 750 Display User Guide 65
16. unlocked If your region is locked contact your Trimble reseller The language packs that have been installed on the display The following information for the lightbar e Status Connected or Disconnected e Serial number e Firmware version Select this item EZ Remote status System status Upgrade options Fault history CFX 750 screen System 9 To view The following information for the EZ Remote e Status Connected or Disconnected e Serial number e Firmware version The current time and date ID CFX 750 The following data about your CFX 750 display e Version and Version date e Serial number e Part number e Hardware Revision System voltage Temperature Storage This is the number of hours of coverage logging remaining before the internal memory is full Operational hours This is the number of hours that the CFX has been operating The status of optional features and extensions Those faults that have occurred recently they may not be currently active The CFX 750 screen has two options e About the Display Shows information about your CFX 750 display including the current version and the serial number e Restore Defaults Restores the display defaults to clear all of your current settings If you choose to restore the default settings the display and lightbar will restart Recalibrate touchscreen The first time you power on the display you must calibrate the touchscreen See Po
17. Boundaries Use this setting to determine how the display manages the boundary after you finish recording If you select this mode The boundary will Do not expand Not alter once you have finished recording Half swath width Expand by one half swath width toward the outside of the pass One swath width Expand by one full swath width toward the outside of the pass Starting Guidance Before you can use the display for guidance you must configure your implement 1 From the guidance screen tap IJ and then tap Create New Field 2 Inthe Create New Field screen tap Implement Setup 134 CFX 750 Display User Guide Mapping and Guidance 6 3 Edit the settings for each option For more information see Implement Setup options page 135 4 Select a pattern type see Guidance Patterns page 139 and continue through the wizard Implement Setup options Option For optimum guidance make sure that you enter accurate information for the implement that is attached to the vehicle Incorrect information may result in gaps and overlaps in coverage The following table describes each of the Implement Setup options Enter a measurement This adjusts guidance Notes between and coverage logging when Implement Width 1 00 328 01 0 305 99 990 m Overlap Skip 394 skip and 394 To avoid skips in application coverage overlap 1000 cm set an intentional overlap Left Right Offset 1969 right and 1969 The implement
18. EED GPS Status The GPS Status screen displays information about your position and the current GPS signal strength Satellite Status The Satellite Status screen displays information about the current satellite constellation 152 CFX 750 Display User Guide GPS 7 The information for each satellite is contained in one line The following table describes fields that the line contains Field Description Sv Satellite number Note GLONASS satellites have an R in front of the satellite number GPS satellites do not El Elevation Az Azimuth L1 L1 SNR L2 L2 SNR Corr Correction appears only if correction is applied Used Used appears only if the satellite is used in position calculation DGPS Status The DGPS Status screen displays which DGPS signal is selected from the GPS Correction Source screen For more information see GPS Setup page 150 Filter Status The Filter Status screen provides diagnostic information about the OnPath advanced filter technology CFX 750 Display User Guide 153 p GPS 154 _ CFX 750 Display User Guide Data In this chapter Introduction m Connected Farm Setup m Manage Data The CFX 750 display saves field data to the its internal memory You can transfer this data to your home or office computer through a USB drive or wirelessly through the Connected Farm server This chapter describes how to manage the data generated by the CFX 750 display CFX 750 Dis
19. EZ Remote Keypad Assignment Wizard 2 2 ee 173 EZ Remote LED Brightness aaa ee 173 EZ Remote Keypad Assignments 2 0 174 EZ Remote operation 0 a 175 Unlock USP Ade see a a eae a ee OO EO eee he ee a A 176 Upgrading your display oo aa ee 176 Unlocking features 3 5 gb cacao na oh ee oe ae Ble hh de be a 176 SECS be ples Sle eo at ey ao amp ke Danan etal gee ee ee ee See te te te et 176 CEN 750 SChCCN as amp SS Se e Goa Bee Saw Kh Oia E SEM OEE RE Ge EE EEE Y 177 Recalibrate LOUCIISChECNiis 4 4 a 4a a a e T G08 ON a oe Ge ae eed a 177 CFX 750 Display User Guide 13 Contents 14 CFX 750 Display User Guide Introduction This manual describes how to install configure and use the Trimble CFX 750 display version 2 00 Even if you have used other Global Navigation Satellite Systems GNSS or application control products before such as the United States Global Positioning System GPS products before Trimble recommends that you spend some time reading this manual to learn about the special features of this product If you are not familiar with GNSS visit the Trimble website www trimble com for an interactive look at Trimble and GNSS About the product The Trimble CFX 750 is an in cab touchscreen display that provides affordable guidance steering and precision agriculture functionality The CFX 750 display includes a built in GPS receiver that you can upgrade to receive GLONASS satellite
20. Enter the gear ratio from the feedback sensor to the seed disk x cane eee eee eee ee E A E Seeds Per Disk Enter the number of holes in the seed disk Tank Bin Setup Status Select On to enable the Tank Bin Tank Bin Setup Select Off to turn the Tank Bin setup off Saar a o 4 Capacity Units Select the units for the Tank Bin gua J m e Capacity Set the total volume for the Tank Bin Se Current Volume Enter the current volume of material in the ae Tank Bin Partial Refill Enter a amount that you want to use fora partial refill Warning Level Enter the amount of material that you want to trigger a Low Material Warning CFX 750 Display User Guide 97 5 Implement Application Controller Row Monitoring Setup Control Setup Edit Screen i Row Monitoring Setup l Mode Select Mode Row Sensor Enable BA es ee HEN Fa Furor Setup Y Y Y Number of Modules Row Member Module Assignment 1 N Row Sensor Enable y Modules po None Modules 1 N Setup Options Description 98 CFX 750 Display User Guide Number of Modules Row Member Module Assignment Row Sensor Enable Select the type of row monitoring that you want to enable The options are e None e Blockage e Seed Count Select the total number of Row Monitoring Modules you have connected
21. Guide Application Main functions Strip till liquid Spreading Definitions Term Section Row Master Switch Box MSB 12 Section Switch Box 12SSB Section Control Module SCM Rate and Section Control Module RSCM Rawson Control Module RWCM Implement Switch Implement Application Controller 5 Liquid section control of up to 48 individual spray nozzles Field IQ Section Control Module s needed using Tru Count LiquiBlock valves Liquid rate control using up to 2 Rawson drives connected to fixed displacement pumps such as CDS John Blue piston pumps to change liquid rate Field IQ Rawson Control Module s needed Liquid rate control using either a PWM or Servo control valve and flow meter Spreading rate control using a Rawson Drive Field IQ Rawson Control Module s needed Spreading rate control using either a PWM or Servo control valve and application rate sensor Definition A number of rows or spray nozzles that are controlled by the Tru Count Air Clutch or Tru Count LiquiBlock valves or boom valves A section can have either a single row nozzle or multiple rows nozzles depending on how the system is set up The individual row unit that material comes from on the implement This can be controlled individually as a single row section or as a group with other rows in a multiple row section Master on off jump start auto manual switch rate selection and increment decreme
22. Material Type The options are Row Crop Seed Liquid Granular Seed 84 CFX 750 Display User Guide Implement Application Controller 5 Granular Fertilizer Anhydrous 5 Once you make your selection tap to return to the Material Management screen From this screen you can now set up a specific material type Setting up a Row Crop Seed in the Material Setup screen Material Management Material Type r Application Rate Row Monitoring Material Name Setup Setup Operation Setup Rates Units Alarms Delays Thresholds Population gt Jump Start Speed Adjustment gt Target Rate 1 gt Seeds Per Pound gt High Alarm gt High Alarm gt Skips Threshold Shutoff Speed gt Target Rate 2 gt Target Rate Units gt Low Alarm gt Low Alarm yl Multiples Lig Minimum Threshold Override Speed Ea Target Rate gt Bushel Weight gt Singulation Low gt Singulation Low Increment gt Average Sample ag Apply Latency to gt Seeds When Off gt Seeds When Off size Boundary Manual Rate Increment No Seeds When No Seeds When _ Misplaced Seeds gt Rate Snap gt On n On Threshold m gt Minimum Rate Blockage
23. Note The AG25 antenna has integrated magnets for easy installation To attach the antenna to a non metal surface you must use the mounting plate 1 Find the mounting location for the antenna at the front of the vehicle roof centered from left to right 2 On the mounting plate remove the protective covers from the adhesive strips 3 Attach the mounting plate to the vehicle roof with the adhesive strips Ensure that the mounting plate is centered along the vehicle roof 4 Connect the antenna cable to the antenna 5 Place the antenna directly on the mounting plate The three magnets embedded in the bottom of the antenna will hold it in place 6 Route the other end of the antenna cable into the cab CFX 750 Display User Guide 23 2 Installing the Display and Antenna 24 CFX 750 Display User Guide Getting Started In this chapter Display basics The Quick Start Wizard Using the setup wizards The guidance screen Using the EZ Remote joystick Reading lightbar patterns On screen icons This chapter describes in general terms how to use the CFX 750 display CFX 750 Display User Guide 25 3 Getting Started Display basics The CFX 750 display provides guidance steering and precision agriculture functionality The display has a touchscreen that you use to operate your system and view guidance information In addition there is a USB port on the display for loading and saving field data Front view
24. Off lower position Sections are closed and rate is set to zero Note All systems must have a Field IQ master switch box 104 CFX 750 Display User Guide Implement Application Controller 5 Field IQ 12 section switch box Note The 12 section switch box is required for section control For rate control only the switch box is optional Only one section switch box can be used on each system Each section switch is automatically assigned to the corresponding module The modules are read from left to right For example switch 1 assigns to the module furthest on the left when standing behind the implement The section switches have different functions depending upon the status of the master Automatic Manual section switch on the master switch box When the Automatic Manual section switch is in the Automatic position If the section switch is in the on up position the section s assigned to it are commanded automatically by the CFX 750 display If the section switch is in the off down position the section s assigned to it are commanded to be off When the Automatic Manual section switch is in the Manual position If the section switch is in the on up position the section s assigned to it are commanded to be on This overrides the CFX 750 display and coverage logging is ignored If the section switch is in the off down position the section s assigned to it are commanded to be off This overrides the CFX 750 displa
25. P N 67258 to the display Connects external devices to the display If you purchase the optional RTK module install the module here For more information see the installation instructions supplied with the radio module CFX 750 Display User Guide 27 3 Getting Started Cleaning the touchscreen To clean the CFX 750 display use the following supplies e Ammonia free glass cleaner Note Do not apply glass cleaner directly to the touchscreen e Soft lint free cotton cloth e 50 isopropyl alcohol 1 Apply asmall amount of glass cleaner to the cloth and gently rub it against the touchscreen 2 To clean off any stains or smudges use a cotton cloth dampened with 50 isopropyl alcohol X Tip Clean the display while it is switched off It is easier to see dirt and fingerprints when the touchscreen is dark Power up To turn on the display press the power button on the rear of the display After a short time the Welcome screen appears 28 CFX 750 Display User Guide Getting Started 3 The first time that you turn on the CFX 750 display the following wizards appear in turn Touchscreen calibration Touchscreen Calibration Magee ibr iti your towchacrean E prering on the panget as it appears iri mihipe locii omacoreeri Take care bo preia Hha cintar of bha bargar fe optimal Cerabicr If the caliber stior A not mufiicient Eh precede wil repeat Attempt 2 You must calibrate the touchscreen before you c
26. amount of side to side boundary overlap before a section shuts down CFX 750 Display User Guide 91 5 Implement Application Controller Select Options Description Section Control Operation Set the coverage allowable rate error Coverage Allowable Rate Error Note This setting is used only if you are running very large fields Section Control Module Location This option appears if the Section Control is set to On Section Control Module Location Select the total number of section control Number of Modules modules for this location Section Control Module Location 2 Se P H Ser ee es Fapa f j Eimi of inkin FrEE eA pAn Erl es i Section Control Module Location Modules Select each module in turn and complete its Section Controller setup before continuing with the next Section Control Module Location module bem Larrea tate Select the serial number of the module that Tenar C n a Fg you want to assign to the location Mih Number of Sections Select the number of section to assign to the selected module a Control Type Select the section control type The options are e Air Clutch The section control module BEHI TH HHF SE ee ee F eta a a ba sends power to the section valve to turn the clutch off e Boom Valve The section control module sends power to the section valve to turn the clutch on e Electric Clutch The section control module sends power to the s
27. between the headland and the infill part of the field Select this mode TO Automatic Automatically switch from headland to infill when the vehicle moves inside the inner headland boundary Manual Use the icons on the guidance screen to select when guidance switches from headland to infill Boundary setup Use the Boundary Setup option to configure e When boundaries are active See Boundaries below e How the display records boundaries See Expand Boundaries below CFX 750 Display User Guide 133 6 Mapping and Guidance Note the following e When you record a boundary the display automatically calculates the area of the boundary and shows this information on the Status tab e When you load a field that contains a boundary the boundary also loads e You can record multiple boundaries in a single field e f your variable rate controller has section switching capability a boundary acts as a switching barrier When you move outside the boundary the controller will automatically switch off the implement Boundaries Select this mode To Enabled Use existing boundaries and create new ones for all your fields Disabled for this field Turn off boundaries for only the current field you are working in When you begin your next field the option will automatically change to Enabled Disabled for all fields Turn off boundaries for all fields you work in including boundaries made with headland patterns Expand
28. delivery to purchasers of Trimble products generally If you have purchased the Product from an authorized Trimble dealer rather than from Trimble directly Trimble may at its option forward the software Fix to the Trimble dealer for final distribution to you Minor Updates Major Upgrades new products or substantially new software releases as identified by Trimble are expressly excluded from this update process and limited warranty Receipt of software Fixes or other enhancements shall not serve to extend the limited warranty period For purposes of this warranty the following definitions shall apply 1 Fix es means an error correction or other update created to fix a previous software version that does not substantially conform to its Trimble specifications 2 Minor Update occurs when enhancements are made to current features in a software program and 3 Major Upgrade occurs when significant new features are added to software or when a new product containing new features replaces the further development of a current product line Trimble reserves the right to determine in its sole discretion what constitutes a Fix Minor Update or Major Upgrade This Trimble software contains Qt 4 5 libraries licensed under the GNU Lesser General Public License LGPL The source is available from http qt nokia com downloads A copy of the LGPL license is included in the appendices of this manual and at ftp ftp trimble com pub
29. guidance screen tap HMM and then tap Create New Field 2 Inthe Create New Field screen tap Pattern Type CFX 750 Display User Guide 139 6 Mapping and Guidance 3 Select the pattern to use Pattern To learn more see Straight AB page 140 A line page 140 Identical curve page 141 Adaptive curve page 141 Pivot page 144 Headland page 144 FreeForm page 145 Straight AB Use a straight AB line when you do not need to define headlands and you want to drive the field in parallel straight lines Note When the vehicle is on a guidance line the line extends 1 km 0 6 miles before point A and 1 km beyond point B This makes it easier to see where the next swath is and to get online yp after a turn Mapping an AB line 1 2 3 4 A line An A line is a straight line defined by a single A point on the line and the heading of the line When you create an A line you must enter a heading in the A Heading screen By default the A heading is the same as the previous AB line An A line is useful when you need guidance exactly parallel to the last AB line for example when Drive to the start point of the master line Tap A and then drive to the end of the line When the icon is highlighted tap The master AB line appears Turn left or right for the next swath As you move toward the next swath it appears on the screen and turns orange to show that it is selected driving adjacent fields
30. is When configured and online the left 5000 cm offset from the vehicle implement should be over the center line guidance line with the vehicle to the side For guidance when driving use the LEDs on the lightbar For more information see Reading lightbar patterns page 41 Forward Back 1188 behind and 384 The implementis not Seta Forward Offset when the Offset forward centered directly implement is forward of the antenna 3018 cm 975 cm under the GPS antenna on the front of the vehicle for EZ for EZ Steer systems Steer systems or forward of the fixed or the fixed axle of the axle of the vehicle for Autopilot vehicle for Autopilot systems systems Set a Back Offset when the implement is behind the antenna on the back of the vehicle for EZ Steer systems or behind the fixed axle of the vehicle for Autopilot systems Implement Draft 393 7 left and 393 7 There is a variable right 1000 0 cm implement draft caused by a side slope and or an implement pulling to one side Implement Mount Choose the type of implement mount Type that is in use CFX 750 Display User Guide 135 6 Mapping and Guidance Using guidance on curved segments After you define a guidance line there are two ways to get guidance e Drive the vehicle through a tight U turn The next guidance line appears e If you are manually logging a FreeForm curve tap s0 to stop defining the current line The FreeForm curve is similar to a
31. is required only for Trimble modems where you have installed a SIM card Wireless Modem settings are as follows The SIM card provider is responsible for providing any settings required Wireless Modem Setup bt estingas Gy presi aah ore Arete Da Green aOapr buen th tire Wireless modem settings Description APN Mobile Network Access Point Name usually required by the network GPRS User Name Mobile Network User name optional setting check with your mobile network if this setting is required GPRS Password Mobile Network Password optional setting check with your mobile network if this setting is required CPIN SIM PIN optional password lock to restrict use of the SIM card The next steps in the wizard guide you through entering VRS settings provided by your Trimble CenterPoint or Network RTK provider The required settings are as follows Server Address 155 63 211 99 alwle ritlyjujifole alsa floth ifk y C3ooG000 CEBE Internet base settings Description Server Name Address RTK VRS CORS base station broadcast name Server Port Number Server Port Number Mount Point Base station mount point CFX 750 Display User Guide 159 8 Data Internet base settings Description VRS User Name VRS Password Network Assigned username Network Assigned password Once the wizard is completed a screen shows the VRS connection status and details all the settings entered The VRS status message types are as follows
32. learn how to connect the CFX 750 display to other the system components see the CFX 750 Display Cabling Guide 20 CFX 750 Display User Guide Installing the Display and Antenna 2 Connecting a standalone CFX 750 display for WAAS EGNOS OmniSTAR XP HP corrections 99 0 OR Description CFX 750 display CFX 750 power cable CFX 750 basic power cable 8 m GPS TNC TNC RT angle cable AG25 GNSS antenna Trimble part number 94110 00 77282 67258 01 50449 77038 CFX 750 Display User Guide 21 2 Installing the Display and Antenna z 3 VO 0 6 O 22 Connecting a standalone CFX 750 display for RTK corrections Description CFX 750 display Note RTK password required CFX 750 power cable CFX 750 basic power cable 8 m GPS TNC TNC RT angle cable AG25 GNSS antenna NMO to TNC 20ft antenna cable and base 900 MHz radio antenna kit CFX 750 Display User Guide Trimble part number 94110 00 77282 67258 01 50449 77038 62120 22882 10 Installing the Display and Antenna 2 Installing the antenna Note To minimize any interference to the GPS signal make sure that the GPS antenna is at least 1 m 3 ft from any other antenna including a radio antenna You may experience interference if you operate the vehicle within 100 m 300 ft of any power line radar dish or cell phone tower
33. price Our General Public Licenses are designed to make sure that you have the freedom to distribute copies of free software and charge for this service if you wish that you receive source code or can get it if you want it that you can change the software and use pieces of it in new free programs and that you are informed that you can do these things To protect your rights we need to make restrictions that forbid distributors to deny you these rights or to ask you to surrender these rights These restrictions translate to certain responsibilities for you if you distribute copies of the library or if you modify it For example if you distribute copies of the library whether gratis or for a fee you must give the recipients all the rights that we gave you You must make sure that they too receive or can get the source code If you link other code with the library you must provide complete object files to the recipients so that they can relink them with the library after making changes to the library and recompiling it And you must show them these terms so they know their rights We protect your rights with a two step method 1 we copyright the library and 2 we offer you this license which gives you legal permission to copy distribute and or modify the library To protect each distributor we want to make it very clear that there is no warranty for the free library Also if the library is modified by someone else and passed on th
34. system will disengage speed e Minimum between 1 0 and 15 9 mph 1 6 and 25 5 kph e Maximum between 1 0 and 18 0 mph 1 6 and 28 8 kph Maximum Angle The EZ Pilot system will not engage when the vehicle is heading toward the guidance line at an angle greater than the Maximum Angle Enter an angle between 5 and 45 degrees Engage Disengage Engage offline The system will not engage when the vehicle is offline further than the Offline Engage Offline distance Enter a distance between 0 5 and 27 0 0 2 and 8 2 m Disengage offline The system will automatically disengage when the vehicle is offline further than the Disengage Offline distance Enter a distance between 0 6 and 27 00 0 2 m and 8 2 m Override sensitivity Control how much force is required to disengage the system Enter an increment between 1 100 Operator timeout Enter a time between 1 60 minutes Vehicle Setup Use this option to view and adjust the settings described below Setting Notes Vehicle type Enter the type of vehicle on which the EZ Pilot system will be installed Wheelbase See Entering vehicle measurements page 59 Antenna height Antenna to axle offset Freeplay left right Drives consistently to one side of the line e lf the vehicle is offline to the left increase the Freeplay offset to the right e If the vehicle is offline to the right increase the Freeplay offset to the left Motor speed Control the speed of the EZ Pilot dri
35. tap P 2 From the Settings screen tap GPS GPS Setup Use the GPS Correction Source screen to choose the type of GPS position corrections that you want to use Source Description SBAS Free satellite based corrections Satellite based e WAAS Wide Area Augmentation System in North America augmentation e EGNOS European Geostationary Navigation Overlay Service in Europe system OmniSTAR VBS Satellite based subscription correction service OmniSTAR XP HP High accuracy satellite based subscription correction service RTK Radio broadcast corrections from a ground based reference station Real Time Kinematic Uncorrected No GPS corrections 150 CFX 750 Display User Guide GPS 7 Position Quality GPS signals can be disrupted by foliage or when the machine moves out of sight of one or more satellites or when one or more satellites move out of sight of the machine or set below the horizon The Position Quality screen provides options that allow you to operate when the quality of GPS position information is compromised Option Description Favor Accuracy Provides the highest level of accuracy Balanced Quality Trades potential accuracy for a slight increase in production time Favor Availability Extends production time further with more potential for reduced accuracy Advanced The Advanced screen enables you to view and adjust advanced GPS settings Advanced Antenna Type Access the Antenna Type screen
36. the Advanced option in the Implement screen to configure the following Boom Setup e Swath Control e Rate Control e Target Rate e Single Section Boom Switching Boom Setup Note The boom setup on the CFX 750 display must match the setup on the LH 5000 controller If the boom setup differs between the display and the LH 5000 controller a warning message appears on the display Use this option to view and adjust the following settings Setting Notes Implement width Enter a width between 1 00 328 01 0 30 99 99 m Fence Nozzles Enter the locations of any fence nozzles Number of sections Enter a number between 1 10 Swath Control Use this option to view and adjust the following settings Setting Notes Boom control Enter a width between 1 00 328 01 0 30 99 99 m Coverage switching Control the amount of boom switching overlap allowed before the section will overlap be switched by the system Enter a value between 1 99 Boundary switching Control the amount of overlap on a boundary before the boom section is overlap switched off Enter a value between 1 99 On Off valve latency Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds CFX 750 Display User Guide 125 5 Implement Application Controller Setting Notes Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area E
37. the EZ Remote joystick page 42 3 Inthe Finished screen select either Choose another button to repeat Step 1 and Step 2 Complete this wizard to exit the wizard EZ Remote LED Brightness Use this screen to adjust the brightness of the LED buttons on the joystick Enter a number between 0 100 CFX 750 Display User Guide 173 9 System EZ Remote Keypad Assignments The EZ Remote Keypad Assignments screen shows the functions that have been assigned to the four programmable buttons EZ Remote Keypad Assignments Dutton 1 Show Trading Map Wise Dutt J Show Cathe Map ee Burton 3 Finish a Lina Burien 4 Fear Cus 174 CFX 750 Display User Guide System 9 EZ Remote operation When the Run screen is active on the CFX 750 display use the buttons on the EZ Remote joystick to perform the functions you have assigned 2 1 Left Right Trigger on back Engage Note The Up Down and Trigger buttons are not supported Use this button To Engage Engage auto steering Up Down N A Right Nudge the guidance line to the right in the guidance screen Left Nudge the guidance line to the left in the guidance screen Trigger N A 1 4 Activate the function that you have assigned To learn how to assign a function to the programmable button see the EZ Remote joystick page 173 CFX 750 Display User Guide 175 9 System Unlock Upgrade Use the Unlock Upgrade screen to e Upgrade your CFX 750 di
38. the display to output NMEA messages on the same port that your controller is connected to 2 3 On the Amazone controller go to the Settings menu Change Remote to Enable For more information on setting up the Amazone controller refer to the Amazone instruction manual Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup Swath Control Rate Control Target Rate Turn Off Rate on Overlap Rate Snapping Boom Setup Note The boom setup on the CFX 750 display must match the setup on the Amazone controller If the boom setup differs between the display and the Amazone controller a warning message appears on the display CFX 750 Display User Guide Implement Application Controller 5 Use this option to view and adjust the following settings Settings Notes Implement width Enter a width between 1 00 328 01 0 30 99 99 m Fence Nozzles Enter the locations of any fence nozzles Number of sections Enter a number between 1 10 Swath Control Use this option to view and adjust the following settings Settings Notes Boom control Enter a width between 1 00 328 01 0 30 99 99 m Coverage switching Control the amount of boom switching overlap allowed before the section will overlap be switched by the system Enter a value between 1 99 Boundary switching Control the amount of overlap on a boundary before the boom section is overlap swit
39. to alter the internal settings of the GPS receiver to ensure optimum accuracy for the antenna Select the antenna you have connected to the display The AG15 and AG25 antennas are white and dome shaped Use SBAS satellites in the position fix Choose this option if you want to use SBAS corrections from WAAS satellites to calculate the GPS positions For example if the display receives position information from six standard GPS satellites and two WAAS satellites the display uses all eight satellites to calculate the GPS position This can extend operating time when limited number of satellites are available Note This option does not work with EGNOS satellites OmniSTAR or RTK corrections CFX 750 Display User Guide 151 7 GPS Force GPS lono Choose On to force the use of modeled rather than real time ionosphere data This setting is designed primarily for locations at the edge of SBAS coverage such as northern Canada and could affect accuracy if used elsewhere OnPath Filter Use the OnPath Filter option to detect and eliminate GPS position jumps and significantly improve pass to pass accuracy Select the option that best describes the surrounding environment Satellite Health You can use this setting to disregard signals from a specific satellite due to concerns about its state For more information contact your reseller Status The Status screen enables you to view the current status of the GPS functions
40. you to configure an implement application controller such as the Field IQ crop input control system To access the Implement screen 1 From the guidance screen tap ge 2 From the Settings screen tap Implement Implement 4 Ea The Implement screen contains two options Advanced and Initial Setup The Advanced option appears only after you have set up your controller using the Initial Setup option To set up your controller 1 From the Implement screen tap Initial Setup The Controller Type screen appears Controller Type Whith comroder do you have commected Note To access all of the available Controller Type options apart from None and Field IQ you must have a VRA unlock code To obtain a VRA unlock code contact your Trimble reseller 2 Select the controller that you are using Note When you change the controller type any open field will close 3 Configure your controller For more information see Field lIQ crop input control system page 76 HARDI 5500 controller page 106 Raven controllers page 109 74 CFX 750 Display User Guide Implement Application Controller 5 Rawson controller page 112 Amazone controller page 116 LH 5000 controller page 118 Prescriptions The CFX 750 display can use a prescription file to determine the rate of application in different areas of the field The prescription file consists of three separate ESRI fi
41. 0000 Ei ke Enable Sensor Enable or disable the sensor Enable Sensor 2S ee OS phie Review the summary If correct tap v Field IQ Hydraulics Test WARNING MOVING PARTS DURING THIS TEST Please stay clear of the implement Ensure the implement is raised the transmission is in PARK and the emergency brake is applied before continuing After the setup wizard is complete the display tests the hydraulics of your system During this test you must run the motor s at the minimum and maximum RPM and make sure the motor s achieve these RPM Field IQ Calibrations After the hydraulics test is complete the display calibrates your system The available calibrations are Field IQ Rawson Control Module e Servo Pump or PWM Pump Pressure Sensors e Implement LIft Switch CFX 750 Display User Guide 101 5 102 Implement Application Controller When the calibration is complete save the data to a configuration file and export it to the USB drive See Chapter 8 Data Field IQ System Status Select this option to view the status for the following e Master Switch Module e Section Switch Module e Rate Control Module e Section Control Module e OEM Switch Interface Accessories Material Assignment screen The Material Assignment screen allows you to easily switch a material in a control location The location button in this example Hoppers shows the name of the location and the material in this e
42. 1 0 30 99 99 m Fence Nozzles Enter the locations of any fence nozzles Number of sections Enter a number between 1 10 Swath Control Use this option to view and adjust the following settings Setting Notes Boom control Enter a width between 1 00 328 01 0 30 99 99 m Coverage switching Control the amount of boom switching overlap allowed before the section will overlap be switched by the system Enter a value between 1 99 Boundary switching Control the amount of overlap on a boundary before the boom section is overlap switched off Enter a value between 1 99 On Off valve latency Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area Enter a distance between 0 00 32 10 0 00 10 00 m Rate control Use this option to view and adjust the following settings Setting Notes On Application rates are sent from a prescription loaded in the display or the target rate manually configured on the display Off The target rate must be set on the LH 5000 controller The CFX 750 display does not send target rates to the controller This is the default setting Note When sending a target rate to the LH 5000 controller that is higher than 99 9 the display rounds to the nearest whole number For example 0 99 9 is not rounded 101 4 is rou
43. 1 N in pains Number of Drives Modules 1 N Width p y i gt Capacity Units Module l gt Capacity y Valve Setup Feedback Setup Y gt Current Volume None Modules 1 N gt Valve Type gt Shaft Encoder Constant gt Partial Refill gt Plumbing i Ley Gear Ration gt Warning Level Calculator gt Gear Ratio gt Seeds Per Disk Select Options Description Rate Control Tap the button and then select On Rate Control Setup BN eee HEN a rary FrEE A pAn Eri EEr E l ET E ieri Rate Control Setup rer Lenn D p ee m E oat Be Lam Bae oe ee oe ee ee Di Sees be eee De iri Rate Control Module Location Number of Drives Select the number of drives that you have at the location Rate Control Module Location EA BS ee HER Fa Prem a poan Bri npr ee LE i mih 94 CFX 750 Display User Guide Select Options Rate Control Module Location Module Modules Rate Control Module Location ee a te i bast oy Mew matra ier 20 ariel Fee M See hi Seer Fei co A Rate Control Module Location Width Drive Setup Drive Setup HE APA H H PESHI Wet ie WIRA LL S Mi mi E E A Implement Application Controller 5 Description Select each module in turn and complete its setup before continuing with the next module 1 Inthe Rate Control Module Location screen select the first module location 2 In the Module screen tap Modules 3 In the Modules screen tap th
44. 50 Display User Guide It applies to version 2 0 of the CFX 750 display software Legal Notices The following limited warranties give you specific legal rights You may have others which vary from state jurisdiction to state jurisdiction Product Limited Warranty Trimble warrants that this Trimble product and its internal components the Product shall be free from defects in materials and workmanship and will substantially conform to Trimble s applicable published specifications for the Product for a period of two 2 years starting from the earlier of i the date of installation or ii six 6 months from the date of original Product shipment from Trimble This warranty applies only to the Product if installed by Trimble or a dealer authorized by Trimble to perform Product installation services Software Components All Product software components sometimes hereinafter also referred to as Software are licensed solely for use as an integral part of the Product and are not sold Any software accompanied by a separate end user license agreement EULA shall be governed by the terms conditions restrictions and limited warranty terms of such EULA notwithstanding the preceding paragraph During the limited warranty period you will be entitled to receive such Fixes to the Product software that Trimble releases and makes commercially available and for which it does not charge separately subject to the procedures for
45. 82 CFX 750 Display User Guide Implement Application Controller 5 2 Inthe Implement Lift Setup screen tap Implement Lift Enable tap Yes in the Implement Lift Enable screen and then tap wi Implement Lift Setup Implement Lift Enable bat estinga Ey preening aah coe Do you ee ho es Pa pintre et Ca ai p eon eo Pees CP Bree eee Gen 8 oe ee 3 You are returned to the Implement Lift Setup screen where you can now set up the following Implement Lift Setup Edit aattings by prassi each ore mdrvidualy Press he greer accepit button Ca cere ree Tap Description Number of Switches Number of implement switches hooked up to the Field IQ system Min Changed Switches Number of switch changes that are required to show the implement in a lifted state For example if three switches are hooked up to the Field IQ system and this setting is set to two the system must see two switches in the lifted position before the implement appears as lifted on the display 4 Tap when done CFX 750 Display User Guide 83 5 Implement Application Controller Setting up a Material 1 Inthe mplement screen tap Material Setup Implement 2 Inthe Material Setup screen tap New Material 3 Inthe Material Management screen tap Material Type Material Management Edit settings by predaing each one Press he greer accepit button Ca cere irae 4 Inthe Material Type screen select the material type you require
46. Blockage p gt gt gt Maximum Rate Sensitivity Sensitivity Once you select a Material Type in the Material Management screen tap Material Name enter a name for the material and then tap pa Once you have done this the following options appear in the Material Management screen e Application Rate Setup Row Monitoring Setup Operation Setup Select each option in turn and complete all settings for that option until you reach the final screen for that option if you then tap v you are returned to the Material Type screen where you can select the next option CFX 750 Display User Guide 85 5 Implement Application Controller The options are as follows Select Application Rate Setup Rates Application Rate Setup Units Units EA es F ee ER Fa Pra nea PIEI eA pAn Bri EEr EA l ET LE i mih Alarms Oy Se by d eg ee ee r Pm ea pAn ed A lT LE ier 86 CFX 750 Display User Guide Options Target Rate 1 Target Rate 2 Target Rate Increment Manual Rate Increment Minimum Rate Maximum Rate Seeds Per Pound Target Rate Units Bushel Weight High Alarm Low Alarm Singulation Low Seeds When Off No Seeds When On Blockage Sensitivity Description Preset rate for position 1 on the rate switch Preset rate for position 2 on the rate switch Rate increase decrease for Target Rate 1 or 2 when the R
47. Calibrating the T2 roll sensor enables the display to calibrate terrain compensation in the EZ Steer controller This step requires you to Enter an accurate value for controller orientation Park the vehicle and mark the inside of both sets of wheels Remain stationary while the system calculates the roll offset This takes approximately 20 seconds Turn the vehicle around and ensure the wheels are over the positions marked in the previous step Remain stationary while the system calculates the roll offset This takes approximately 20 seconds CFX 750 Display User Guide 53 4 Vehicle EZ Steer calibration In this step you must drive and engage on a straight AB line in a clear field 1 Begin driving and then tap A 2 Drive 160 feet and then tap B A series of calibration screens will allow you to adjust any settings as necessary Operation You must calibrate and set up the EZ Steer system before operation Engaging the system Before you can engage the EZ Steer system you must e opena field in the guidance screen e define an AB line e position the vehicle within the configured engage limits To engage the system 1 Point the nose of the vehicle toward the guidance line and drive at operational speed 2 Doone of the following From the guidance screen tap Press the optional remote engage foot pedal Disengaging the system The EZ Steer system automatically disengages when one of the following happens e Th
48. Description Sensor Type Air Pressure Select the type of sensor that you want to set a Liquid Pressure up eect ne rye ot enter ps ae ts Em NH3 Pressure Vacuum Pressure RPM Sensor Bin Status Sensor Gate Height Sensor CFX 750 Display User Guide 99 5 Implement Application Controller Select Options Sensor Name Sensor Name ee _ O O CSBae0000 123 Module Assignment Module Assignment EnH FF mA eee ee F Ima Input Location Pressure Sensors only Input Location BEHI F ee ee FI HEF RPM Calibration RPM Sensors only RPM Calibration Re i he a ees ES peat Alarm on Change Bin Status Sensors only 100 CFX 750 Display User Guide Description Use the on screen keyboard to enter a name for the sensor Select the serial number of the module the sensor is connected to Select the location the pressure sensor is connected to on the module Enter the Pulse per Revolution number for the RPM sensor Select the change of state that will trigger the sensor alarm The options are e Low to High The alarm is triggered when the module sees the sensor go from 0 V to 12 V e High to Low The alarm is triggered when the module sees the sensor go from 12 V to 0 V Implement Application Controller 5 Select Options Description Alarm Text Bin Status Sensors only Enter the text you want to appear when the alarm is triggered Alarm Text ee CSBaG
49. Display User Guide 49 4 Vehicle Engage Options Use this option to view and adjust the settings described below Setting Minimum Maximum speed Maximum Angle Engage Disengage Offline Override sensitivity EZ Steer external switch EZ Steer operator timeout Notes Enter the minimum and maximum speeds at which the EZ Steer system will disengage e Minimum between 1 0 and 15 9 mph 1 6 and 25 5 kph e Maximum between 1 0 and 18 0 mph 1 6 and 28 8 kph The EZ Steer system will not engage when the vehicle is heading toward the guidance line at an angle greater than the Maximum Angle Enter an angle between 5 and 45 degrees Engage offline The system will not engage when the vehicle is offline further than the Engage Offline distance Enter a distance between 0 5 and 27 0 0 2 and 8 2 m e Disengage offline The system will automatically disengage when the vehicle is offline further than the Disengage Offline distance Enter a distance between 0 6 and 27 00 0 2 m and 8 2 m Control how much force is required to disengage the system Enter an increment between 1 100 Enable or disable additional safety features Enter a time between 1 60 minutes Vehicle Setup Use this option to view and adjust the settings described below Setting Vehicle type Wheelbase Antenna height Antenna to axle offset Angle per turn Freeplay left right Motor speed Motor direction is rev
50. E EES e HEED EE YE ODS 145 COVeIece JOB INE e weeds eee eos eee ERR eee ee es ea eee eee 147 CFX 750 Display User Guide 11 Contents The pause resume function 2 a a a a 147 Curve smoothing aoaaa 147 IF ee wee rnnr ke Sees eee be heehee Se 149 WUIOOUCTION 244egeauatsteeeayeott Scene er bee ees ees renr 150 GeO he aa ee hehe ee eee eRe eee eee eee eee aed ee 150 Posion QUAI sh oa eee eee he ee Ree ER eee eee eee ee eee eS 151 POVANCEO 2 Aenea e OEE eee eee eee eee Ge 151 Antenna TYDE a esse 4866 Rk FR Owe eee ee eee eee oe oe ee amp os 151 Use SBAS satellites in the position fiX aooaa 151 FOrCe GPSIONG 44 6 ba Ser eteeeow seer eset eae eau eeee ore 5b i 152 OnPath Filter 2a lt neee eee ee eee ee eA ewe eee ee wee ee 152 satellite Health 2s 245 42ce55 ee baw te bbe Ree edd aS EE DS Sw Be 152 DlQtUG oe eae et bee eee eee Eee ee ee eee eee eee GY 152 GPa SlaclSa ee ee ek Ae be Se ee eee ehh ee eee ee ee eae 152 Saleh Status gt gt aaa eR Rae eee SR a RAAR eee eee ee es 152 DGPS Status ae hk ee eee RRM R RSE ERE oS ee eS 153 Filter Status 2s 486648 6556 oe ee wade lacus bao bau eo 620 5 4 153 E Esnerik aaaea 155 IAOOUCON rrr rerenres serne SSeS Ree eee ee ee 156 DCM 300 modem aoaaa a 156 PaSsCO0Gs 22454 ee ee eee hae eee eet eee tbe oh eed ees 156 Configuring the display for VRS corrections a e ee 158 Configuring VRS settings oaoa ee 159 Connected Farm Setup 244 4 4bwedddeeanee eke eee ee beste t
51. EA Port Parameters screen specify the following Use this setting To NMEA output port Specify the port that the NMEA device is connected to Baud Rate Set the transmit receive rate of the serial port in bits per second bps Data Parity Select how the parity bit is added to the data transfer Note For the CFX 750 display to communicate with another device the Port Parameters on the display must match those of the device In the Message Selection screen select from the list of available NMEA messages Message Description GGA Position and fix related data VTG Speed and heading GSA Position fix mode satellites used and the dilution of precision DOPs GLL Position and status RMC Status position speed over ground SOG date and magnetic variation of the position ZDA Date and time GSV Satellite information 172 CFX 750 Display User Guide System 9 EZ Remote joystick The EZ Remote option appear in the System menu only if you have an EZ Remote joystick installed For more information see the EZ Remote Joystick Quick Reference Card Use the EZ Remote screen to e assign functions to buttons 1 4 on the EZ Remote joystick e adjust the LED brightness of the buttons review your button assignments EZ Remote EZ Remote Keypad Assignment Wizard 1 On the CFX 750 display tap the first EZ Remote joystick button to program 2 Inthe Choose a Function screen tap the function to assign to the joystick button See Using
52. Enter a value between 2 12 3 30 cm Mapping Use this setting to set warning distance and recording positions for the following features Point Line e Area Warning distance You can set a warning distance so that the CFX 750 display alerts you when your machine approaches a feature CFX 750 Display User Guide Mapping and Guidance 6 As the machine moves to within the specified distance a warning screen appears on the display If you have an EZ Steer or Autopilot system with a sonalert connected an audible alarm also sounds You can set the warning distance to between 0 00 984 03 0 0 300 0 m Recording position Choose the point at which a feature is recorded When your vehicle is at this point the feature will be recorded Delete features Use this function to delete point line and area features from a selected field Only the features are deleted not the field itself FreeForm Recording Use this setting to choose how the display records a FreeForm pattern Select this mode To Manual Use the icons on the guidance screen to control when the path is recorded To start recording tap o to stop tap O Record with coverage Automatically begin and end recording the FreeFrom pattern when coverage logging begins and ends Note You can still use the FreeForm recording icon to manually override recording Headland lnfill Switching Use this setting to choose how guidance switches
53. For planters this is typically the seeding units or the midpoint of several rows of tools Hitch To Ground Contact Point CFX 750 Display User Guide 81 5 Implement Application Controller Tap Description Implement Draft Distance that the implement drifts away from the center line of the vehicle This setting is used to adjust the implement back on line if the implement is physically drifting offline in the field Note This setting is similar to the Left Right Offset Implement Draft Implement Mount Select the required mount type PoP ene gee Type e Hitched 3pt The implement is mounted rss messe m snunsa ns hoe lt a on a 3 point hitch which means that the E implement rotates around the vehicle Note When the vehicle makes a slight correction you will instantly see a change in the implement s location e Drawbar The implement is attached by a implement Mount Type drawbar which means that the pee i dy ai implement rotates around its ground O contact point Fat OOo e Note When the vehicle makes a correction ty you may not see a change in the implement until a certain distance has been traveled 3 Once you enter all the required measurements tap m Setting up the Implement Switches 1 Inthe mplement Switches screen tap Implement Lift Setup Implement Switches Edit sattinga by predding gach one irdd Press he Greer accept button t cere rae
54. HAS BEEN ADVISED OF THE POSSIBILITY OF ANY SUCH LOSS AND REGARDLESS OF THE COURSE OF DEALING WHICH DEVELOPS OR HAS DEVELOPED BETWEEN YOU AND TRIMBLE BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY OR FULLY APPLY TO YOU PLEASE NOTE THE ABOVE TRIMBLE LIMITED WARRANTY PROVISIONS WILL NOT APPLY TO PRODUCTS PURCHASED IN THOSE JURISDICTIONS E G MEMBER STATES OF THE EUROPEAN ECONOMIC AREA IN WHICH PRODUCT WARRANTIES ARE THE RESPONSIBILITY OF THE LOCAL DEALER FROM WHOM THE PRODUCTS ARE ACQUIRED IN SUCH A CASE PLEASE CONTACT YOUR TRIMBLE DEALER FOR APPLICABLE WARRANTY INFORMATION 4 CFX 750 Display User Guide Official Language THE OFFICIAL LANGUAGE OF THESE TERMS AND CONDITIONS IS ENGLISH IN THE EVENT OF A CONFLICT BETWEEN ENGLISH AND OTHER LANGUAGE VERSIONS THE ENGLISH LANGUAGE SHALL CONTROL Registration TO RECEIVE INFORMATION REGARDING UPDATES AND NEW PRODUCTS PLEASE CONTACT YOUR LOCAL DEALER OR VISIT THE TRIMBLE WEBSITE AT www trimble com register UPON REGISTRATION YOU MAY SELECT THE NEWSLETTER UPGRADE OR NEW PRODUCT INFORMATION YOU DESIRE Notices This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a comme
55. ITNESS FOR A PARTICULAR PURPOSE TITLE AND NONINFRINGEMENT THE STATED EXPRESS WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF TRIMBLE ARISING OUT OF OR IN CONNECTION WITH ANY PRODUCTS OR SOFTWARE BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW LIMITATIONS ON DURATION OR THE EXCLUSION OF AN IMPLIED WARRANTY THE ABOVE LIMITATION MAY NOT APPLY OR FULLY APPLY TO YOU NOTICE REGARDING PRODUCTS EQUIPPED WITH TECHNOLOGY CAPABLE OF TRACKING SATELLITE SIGNALS FROM SATELLITE BASED AUGMENTATION SYSTEMS SBAS WAAS EGNOS AND MSAS OMNISTAR GPS MODERNIZED GPS OR GLONASS SATELLITES OR FROM IALA BEACON SOURCES TRIMBLE IS NOT RESPONSIBLE FOR THE OPERATION OR FAILURE OF OPERATION OF ANY SATELLITE BASED POSITIONING SYSTEM OR THE AVAILABILITY OF ANY SATELLITE BASED POSITIONING SIGNALS Limitation of Liability TRIMBLE S ENTIRE LIABILITY UNDER ANY PROVISION HEREIN SHALL BE LIMITED TO THE AMOUNT PAID BY YOU FOR THE PRODUCT OR SOFTWARE LICENSE TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL TRIMBLE OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER UNDER ANY CIRCUMSTANCE OR LEGAL THEORY RELATING IN ANY WAY TO THE PRODUCTS SOFTWARE AND ACCOMPANYING DOCUMENTATION AND MATERIALS INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS REGARDLESS WHETHER TRIMBLE
56. LH 5000 controller If the boom setup differs between the display and the LH 5000 controller a warning message appears on the display Use this option to view and adjust the following settings Setting Notes Implement width Enter a width between 1 00 328 01 0 30 99 99 m Fence Nozzles Enter the locations of any fence nozzles Number of sections Enter a number between 1 10 Swath Control Use this option to view and adjust the following settings Setting Notes Boom control Enter a width between 1 00 328 01 0 30 99 99 m Coverage switching Control the amount of boom switching overlap allowed before the section will overlap be switched by the system Enter a value between 1 99 Boundary switching Control the amount of overlap on a boundary before the boom section is overlap switched off Enter a value between 1 99 CFX 750 Display User Guide 119 5 Implement Application Controller Setting Notes On Off valve latency Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area Enter a distance between 0 00 32 10 0 00 10 00 m Rate control Use this option to view and adjust the following settings Setting Notes On Application rates are sent from a prescription loaded in the display or the target rate manually
57. License whose permissions for other licensees extend to the entire whole and thus to each and every part regardless of who wrote it Thus it is not the intent of this section to claim rights or contest your rights to work written entirely by you rather the intent is to exercise the right to control the distribution of derivative or collective works based on the Library In addition mere aggregation of another work not based on the Library with the Library or with a work based on the Library on a volume of a storage or distribution medium does not bring the other work under the scope of this License 3 You may opt to apply the terms of the ordinary GNU General Public License instead of this License to a given copy of the Library To do this you must alter all the notices that refer to this License so that they refer to the ordinary GNU General Public License version 2 instead of to this License If a newer version than version 2 of the ordinary GNU General Public License has appeared then you can specify that version instead if you wish Do not make any other change in these notices Once this change is made in a given copy it is irreversible for that copy so the ordinary GNU General Public License applies to all subsequent copies and derivative works made from that copy This option is useful when you wish to copy part of the code of the Library into a program that is not a library 4 You may copy and distribute the Library or
58. NG ss eeraa nasri rt Erara ee eee EHH RS 133 Headland Infill Switching aoaaa a a 133 Boundary setup ee 133 Starting Guidance amp u amp 58 we oe ee eH wo Oe CRO GEE Se Bee we SE OY 134 Implement Setup options 2 ee 135 Using guidance on curved segments 1 0 ee a 136 Using guidance on straight segments 2 ee 136 Creating straight sections on Headland or Curve swaths 136 FICIOS 644 6484 ae he eeee eee eee ee eee eee ee eee eee ee ee 136 Creating a new field 464 4 5 h 506 26 eee eee oe eG es eG ee 137 Selecting loading a field oaa aaa 137 Adding an AB line to a current field aaa a aa 137 Selecting loading an AB line into a field oaa aaa a a 137 RECOrd KEEDINE e saa rrerrryir iyere PEERS SS ee be ee ee 138 Resetting guidance aoaaa ee 138 G ldance lines 2 eae e4enceeae heated eae he ennaa 138 Distance between guidance lines 1 139 HeadlahdS 6 2a6ebearesetaeauner ester eee eee ee BES Se Stee ee 139 On screen appearance oaaao a a 139 Guidance Patterns oaa amp w amp ook we we a on ae OK HE BO BS Hm x 139 SUAISNL AD Ase wah eee be eee ee eee ee eee eee tees 140 PRuGanee sone ehabeoeeeewanesceaeatbddaauntenneceaaas 140 Identical CUVE e a e esa ee ee ee ee oe es 141 Adaptive curve 2 a 141 FINO 4 u32a4 4 Ae ORR EEE ee eee eA ee eRe eee E ee GG 142 Headland suman eea deen eeeeeae Bee eeehee eee eee eeEEEE SS 144 FICCFOM 4 44 54 2608 88 6 EHS ERE EEE EE
59. Press the optional remote engage foot pedal Disengaging the system The Autopilot automated steering system automatically disengages when one of the following happens e The vehicle is outside the configured engage limits e You pause the system e GPS positions are lost e You tap the Engage button on the guidance screen You can manually disengage the system by turning the steering wheel this overrides the electric motor Check this setting before you start using the system by engaging on a line and then turning the wheel until the system disengages To adjust the amount of force required to disengage the system change the Override Sensitivity in the Engage Options screen Engage status indicators Engage status Icon color Ready to engage Engaged Cannot engage After using the Autopilot automated steering system Before you leave the vehicle turn off the system power switch or remove the power plug 72 CFX 750 Display User Guide Implement Application Controller In this chapter Introduction Field IQ crop input control system HARDI 5500 controller Raven controllers Rawson controller Amazone controller LH 5000 controller Vaderstad Checking the implement connection This chapter describes how to configure the CFX 750 display to use an implement application controller CFX 750 Display User Guide 73 5 Implement Application Controller Introduction The options in the mplement screen enable
60. R 210 et CNR 119 du Canada Australia and New Zealand Class A Statement Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Australia and New Zealand This product conforms with the regulatory requirements of the Australian Communications Authority ACA EMC framework thus satisfying the requirements for C Tick Marking and sale within Australia and New Zealand Notice to Our European Union Customers For product recycling instructions and more information please go to www trimble com ev shtml Recycling in Europe To recycle Trimble WEEE Waste Electrical and Electronic Equipment products that run on electrical power Call 31 497 53 24 30 and ask for the WEEE Associate Or mail a request for recycling instructions to Trimble Europe BV c o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel NL Safety gt Warnings A A gt D Always follow the instructions that accompany a Warning or Caution The information they provide is intended to minimize the risk of personal injury and or damage to property In particular observe safety instructions that are presented in the following format WARNING This alert warns of a potential hazard which if not avoided can cause severe injury CAUTION This alert warns of a hazard or unsafe practice which if not avoided can cause i
61. RNING When the implement is down and the master switch is in the On position the machine is fully operational Take all necessary precautions to ensure user safety Failure to do so could result in injury or death WARNING The display contains a single use Lithium sulfide LISO battery Do not expose the battery to temperatures greater than 71 C 160 F as the battery may explode WARNING MOVING PARTS DURING THIS TEST Please stay clear of the implement Ensure the implement is raised the transmission is in PARK and the emergency brake is applied before continuing Working with anhydrous ammonia e Contact your NH3 supplier to review all safety requirements associated with anhydrous ammonia NH3 e Always wear correct personal protective equipment This includes but is not limited to Goggles or face shield Protective suit and gloves Respirator e Do not allow anyone to operate the system without proper instruction and training e Stand up wind when working around NH3 and related equipment e Always keep NH3 equipment away from buildings livestock and other people Never work on NH3 equipment in confined spaces e Before you attempt to transport the implement discharge the system of all NH3 and completely shut down the system See Discharging the system page 7 e f symptoms of illness occur during or shortly after use of NH3 products seek immediate medical attention e Keep a source of clean wate
62. USER GUIDE CFX 750 Display Revision A OS m March 2012 Trimble Agriculture Business Area Trimble Navigation Limited Trimble Agriculture Division 10355 Westmoor Drive Suite 100 Westminster CO 80021 USA trimble_support trimble com www trimble com Legal Notices Copyright and Trademarks 2010 2012 Trimble Navigation Limited All rights reserved Trimble the Globe amp Triangle logo AgGPS EZ Guide EZ Steer T2 and Tru Count Air Clutch are trademarks of Trimble Navigation Limited registered in the United States and in other countries Autopilot Center Point CFX 750 CenterPoint Connected Farm EZ Pilot Field IQ FreeForm VRS T3 and Tru Count LiquiBlock are trademarks of Trimble Navigation Limited For STL support the software uses the Moscow Center for SPARC Technology adaptation of the SGI Standard Template Library Copyright 1994 Hewlett Packard Company Copyright 1996 97 Silicon Graphics Computer Systems Inc Copyright 1997 Moscow Center for SPARC Technology Microsoft Windows Activex Excel and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Portions Copyright 2009 Nokia Corporation and or its subsidiary ies Portions Copyright 2003 Bitstream Inc All other trademarks are the property of their respective owners Release Notice This is the March 2012 release Revision A of the CFX 7
63. a portion or derivative of it under Section 2 in object code or executable form under the terms of Sections 1 and 2 above provided that you accompany it with the complete corresponding machine readable source code which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange If distribution of object code is made by offering access to copy from a designated place then offering equivalent access to copy the source code from the same place satisfies the requirement to distribute the source code even though third parties are not compelled to copy the source along with the object code 5 A program that contains no derivative of any portion of the Library but is designed to work with the Library by being compiled or linked with it is called a work that uses the Library Such a work in isolation is not a derivative work of the Library and therefore falls outside the scope of this License However linking a work that uses the Library with the Library creates an executable that is a derivative of the Library because it contains portions of the Library rather than a work that uses the library The executable is therefore covered by this License Section 6 states terms for distribution of such executables When a work that uses the Library uses material from a header file that is part of the Library the object code for the work may be a derivative work of the Library even th
64. an the cost of performing this distribution d If distribution of the work is made by offering access to copy from a designated place offer equivalent access to copy the above specified materials from the same place e Verify that the user has already received a copy of these materials or that you have already sent this user a copy For an executable the required form of the work that uses the Library must include any data and utility programs needed for reproducing the executable from it However as a special exception the materials to be distributed need not include anything that is normally distributed in either source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable It may happen that this requirement contradicts the license restrictions of other proprietary libraries that do not normally accompany the operating system Such a contradiction means you cannot use both them and the Library together in an executable that you distribute 7 You may place library facilities that are a work based on the Library side by side in a single library together with other library facilities not covered by this License and distribute such a combined library provided that the separate distribution of the work based on the Library and of the other library facilities is otherwise permitted and provided that you do these t
65. an use the display to do this follow the onscreen instructions e The Quick Start wizard To configure your system properly make sure that you run the entire wizard See The Quick Start Wizard page 32 Power down To turn off the CFX 750 display hold down the power button for three seconds While holding down the power button the Power Down In Progress screen appears Power Down In Progress ower dann Fi peges Aali Butten ta cancel Seconds util power dawn 2 Note To cancel the power down process release the power button before the three second countdown is complete CFX 750 Display User Guide 29 3 Getting Started Resetting the display Occasionally you may want to reset the display settings There are two ways to do this e Soft reset This returns all settings to the factory defaults All saved field data remains intact e Hard reset This returns all settings to the factory defaults and deletes all saved data including any field data Note Do not perform a hard reset unless it is absolutely necessary or you are instructed to do so by Trimble Technical Support Soft reset 1 Power down the display and then power it on 2 Wait until the status bar at the bottom of the second startup screen is over half full Oe 3 Press the power button and top brightness control button at the same time 4 Hold the buttons down until the display beeps Hard reset 1 Power down the display and then p
66. are a first time user of the Connected Farm service select Initial Setup to open a setup wizard Connected Farm Setup Connected Farm setup option Description Connected Farm Turns Connected Farm functionality on off Device Name User defined name to identify the display in Farm Works software Check Server Controls how often to check for new jobs or data Modem Only Setup Checks for a connected modem Network Registration Connected Farm registration Initial Setup First time Connected Farm setup wizard This requires a DCM 300 modem to be connected and in an area with good wireless service Once the initial setup is complete you can change individual settings as required Sending Field data using Connected Farm Connected Farm field data includes event coverage field boundaries guidance lines area features line features and point features You can wirelessly transfer all this data from the CFX 750 display to the office With the Connected Farm service enabled field event data is automatically sent to the Connected Farm service when you close the event To manually send field events 1 Tap P and then select Data Manage Data Connected Farm Send Data Send Data CFX 750 Display User Guide 163 8 Data Use the Client Farm Field and Event options to select an individual field or all events farms or fields for a client Send Fields to Connected Farm pene the geen ee Gon o eee ore aera Mae to the Commec
67. ate Adjustment Switch is clicked once Valve movement when the Rate Adjustment Switch is used with the Rate Switch set to Manual Minimum rate that will be applied with this material Maximum rate that will be applied with this material Number of seeds per pound If you select this option you can select on the following in the Target Rate Units screen e Default kS a or kS ha e Bushels Weight per bushel Triggers when the seed sensor population rises above the selected percentage from the Target Rate for longer than the delay time Triggers when the seed sensor population drops below the selected percentage from the Target Rate for longer than the delay time Triggers when the singulation drops below the selected percentage lower than 100 for longer than the delay time Triggers when this percentage of seeds are detected while the sections are off for longer than the delay time Triggers when this percentage of seeds are not detected for longer than the delay time Triggers when less than this amount of material is sensed for longer than the delay time Select Rate Monitoring Setup Delays Delays BA ee ee rures Rate Monitoring Setup Thresholds Rate Monitoring Setup Population Adjustment Population Adjustment Options High Alarm Low Alarm Singulation Low Seeds When Off No Seeds When On Blockage Alarm Skips Threshold Multiples Threshold Avera
68. attention to the difference between a work based on the library and a work that uses the library The former contains code derived from the library whereas the latter must be combined with the library in order to run GNU LESSER GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING DISTRIBUTION AND MODIFICATION 0 This License Agreement applies to any software library or other program which contains a notice placed by the copyright holder or other authorized party saying it may be distributed under the terms of this Lesser General Public License also called this License Each licensee is addressed as you A library means a collection of software functions and or data prepared so as to be conveniently linked with application programs which use some of those functions and data to form executables The Library below refers to any such software library or work which has been distributed under these terms A work based on the Library means either the Library or any derivative work under copyright law that is to say a work containing the Library or a portion of it either verbatim or with modifications and or translated straightforwardly into another language Hereinafter translation is included without limitation in the term modification Source code for a work means the preferred form of the work for making modifications to it For a library complete source code means all the source code for all modules it contains
69. awson controller oaoa 112 DOUU o PENEN E E E E EERE EERO Ee 112 e e E E E E E E eee ee eee ee 113 Operation 2 ek cae Gp Raen thee y ininda disada HERA RHE EES 114 Amazone controller 000 ce ee wwe eee ee tw ee eee 116 SEUD oes eee ee we eos Ree ee eee ea ee a ae ee ee ee 116 Advanced 6 oss ce ee ee eee Ree ee eo eee eee 6G e 116 ODETAUON gt isese Fede td a ed eGR EEE See eee eh eee eS Ew EO 118 LH 5000 controller a oa 118 CSc Ini o E E E eee Rw EE EEE 118 Advanced 6 sssssriassa iiser kbisid ipt Sarari id REE 119 10 CFX 750 Display User Guide Contents Operation 2 dR Ree eek EERE Se Ee MRE ARES EEE DEER ee eee G 120 Vader taU a whee oS Oe ee REESE ERS EES S ESE SRG 122 o clo AE ee a ae ee a a a a ea ae E a ee ee ee ee ae 122 Advanced 6 454 44655 ee eee eee eee SEREA EEE ORS Se Ochre Go 122 Single section boom switching 2 ee 124 Bogballe controller 0 124 SS o a E a ee 124 Ada A os nee ehnt eee Seeeueengaeetbheaeee gabe eee eo be 125 Single section boom switching oaoa 126 Checking the implement connection oaaae ee 126 Mapping and Guidance 0c ee eevee nceves 129 IALFOGUICHION 2 a2 lt c4 26244 kde eeeabbaw eee et aaaaeh be aeeadeaaaad 130 Configuring the Guidance settings oaaae e a a a 130 Turm Settings 24 e e485 4 2 AAR Soe ee eee eee eee ee ae 131 Coverage Settings 2 ee 132 Nudge Settings 1 132 WEDDING s s 5656 4 4a ea eA eR Oe EE ee ERE oS eG S 132 FrECFORNPRECOIGI
70. between 2 and 4 mph 3 Allow the system to operate for 20 seconds until you receive a message that the calibration is complete 4 Repeat Step 1 through Step 3 for left angle per turn calibration EZ Pilot system calibration In this step you must drive and engage on a straight AB line in a clear field 1 Begin driving and tap AN 2 Drive 160 feet and then tap B A series of calibration screens will allow you to adjust any settings as necessary Operation You must calibrate and set up the EZ Pilot system before operation CAUTION Do not operate the EZ Pilot system while driving in reverse gear Engaging the system Before you can engage the EZ Pilot system you must e Open afield in the guidance screen e Define an AB line e Position the vehicle within the configured engage limits CFX 750 Display User Guide 61 4 Vehicle To engage the system 1 Point the nose of the vehicle toward the guidance line and drive at operational speed 2 From the guidance screen or the optional remote control tap CAUTION If you use the vehicle on a public roadway you must put the red EZ Pilot system override switch in the off position To engage the EZ Pilot system do one of the following e Tap Engage on the Run screen e Press the Engage button on the EZ Remote joystick see EZ Remote joystick page 173 e Use an external foot or rocker switch see Engaging the EZ Pilot system using an external foot or rocker switch
71. ce settings 1 From the guidance screen tap g 2 From the Settings screen tap Guidance Guidance 3 Select the options to configure Option To learn more see Turn Settings page 131 Coverage Settings page 132 Nudge Settings page 132 Mapping page 132 FreeForm Recording page 133 Headland Infill Switching page 133 Boundary Setup page 133 130 CFX 750 Display User Guide Mapping and Guidance 6 Turn Settings The available Turn Settings are described below Minimum turn radius mode This setting smoothes corners on curved AB lines which optimizes the accuracy of your auto steer system when steering curves Use this mode To Automatic Set the radius to 80 of the swath width or 32 8 10 m whichever is larger This is the default mode Disabled No attempt is made to keep the corners above a minimum turn radius Note If you use this mode curves may be very tight and the auto steering system may be unable to successfully complete the turn Manual Manually choose the minimum radius Tight turn alert threshold The CFX 750 display alerts you when your machine is within a specified distance of a tight turn The threshold is set between 1 and 10 To increase the sensitivity of the alert lower the number Auto U turn detection Auto U turn detection operates only on FreeForm and adaptive curve patterns For more information see Guidance Patterns page 139 Use this mode To On Au
72. ced Fam a ism Pri Feii a tam kaa Pm ees ee I T wa H Receiving Field data through the Connected Farm service With the Connected Farm service you can wirelessly transfer field information from the office to the CFX 750 display Field data includes field boundaries guidance lines prescriptions area features line features and point features To receive data from the Connected Farm service 1 Select the Wrench icon and then select Data Manage Data Connected Farm Retrieve Data From the Retrieve Data screen tap Check Server to check for and download new field data from the Connected Farm server Once the data is downloaded select the Get Fields from Connected Farm option to import the data into the display As new data is received use the Get Fields from Connected Farm function to import the most recent data into the display Retrieve Data The Connected Farm service adds a status icon to the Run screen that shows the status of Connected Farm operation An icon at the top right of the screen shows if field data is being sent or received 164 CFX 750 Display User Guide Data 8 When data is being sent or received an orange arrow blinks between the tractor and office computer Manage Data The Manage Data screen enables you to handle your data through the USB drive or the display s internal memory USB The USB screen enables you to e Retrieve the field data and CFX 750 configuration
73. ched off Enter a value between 1 99 On Off valve latency Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area Enter a distance between 0 00 32 10 0 00 10 00 m Rate control Use this option to view and adjust the following settings Settings Notes On Off Application rates are sent from a prescription loaded in the display or the target rate manually configured on the display The target rate must be set on the Amazone controller The CFX 750 display does not send target rates to the controller This is the default setting Note When sending a target rate to the Amazone controller that is higher than 99 9 the display rounds to the nearest whole number For example 0 99 9 is not rounded 101 4 is rounded to 101 Target Rate Set the target application rate that will be sent to the Amazone controller Enter a rate between 0 0 11000 0 CFX 750 Display User Guide 117 5 Implement Application Controller Turn Off Rate on Overlap Use this option to view and adjust the following settings Settings Notes Yes Does not spray over an area that has been previously sprayed No Sprays over an area that has been previously sprayed Operation When you connect the Amazone controller to the display the following items appear on th
74. configured on the display Off The target rate must be set on the LH 5000 controller The CFX 750 display does not send target rates to the controller This is the default setting Note When sending a target rate to the LH 5000 controller that is higher than 99 9 the display rounds to the nearest whole number For example 0 99 9 is not rounded 101 4 is rounded to 101 Target Rate Set the target application rate that will be sent to the LH 5000 controller Enter a rate between 0 0 11000 0 Turn Off Rate on Overlap Use this option to view and adjust the following settings Setting Notes Yes Does not spray over an area that has been previously sprayed No Sprays over an area that has been previously sprayed Operation 120 CFX 750 Display User Guide Implement Application Controller 5 When the LH 5000 variable rate controller is connected to the display the following items appear on the CFX 750 display s guidance screen T 20 0 gal a A 0 0 gala Description Quick Access icon Boom section status indicators Target rate Actual rate Application indicator Ds Pe a Mapping i a h Can t engage Too slow atatt of hoa Ef gt A oe Notes See Quick Access icon page 38 Shows the current state of each boom section e Green Enabled and spraying e Gray Enabled but not currently spraying e Red The section is off the switch is off If a prescription is loaded P displays t
75. ct location when the guidance was paused This enables you to return to that position in the field When you pause guidance e Your current position relative to the pause icon appears in the status bar at the top of the screen e The guidance line that you were on is displayed even if you drive onto another swath e The pause resume icon remembers the vehicle position even when the lightbar is turned off Curve smoothing By default the CFX 750 display smooths curves for improved guidance and auto steering You can disable curve smoothing on tight turns curves that have a radius of less than 3m 10 ft Note If you disable curve smoothing the CFX 750 display or the Autopilot system may not be able to quto steer around the tighter turns Be careful when you disable curve smoothing To disable curve smoothing 1 Inthe Settings screen tap Guidance and then tap Turn Settings 2 Tap Minimum Turn Radius Mode and then select Automatic Disabled or Manual CFX 750 Display User Guide 147 6 Mapping and Guidance 148 CFX 750 Display User Guide GPS In this chapter This chapter describes how to set up the GPS receiver Introduction GPS Setup E m m Position Quality m Advanced E Status CFX 750 Display User Guide 149 7 GPS Introduction The GPS menu enables you to select which GPS system and correction source to use and the GPS quality tolerance To access the menu 1 From the guidance screen
76. ction Display Advanced EZ Remote joystick Unlock Upgrade Status CFX 750 screen Recalibrate touchscreen This chapter describes how to configure the system settings CFX 750 Display User Guide 167 9 System Introduction The System menu enables you to adjust a variety of the CFX 750 display settings To access the System menu 1 From the guidance screen tap Pa 2 From the Settings screen tap a The following screen appears Statue The following sections describe the various items that are available in the System menu Display Use the items in the Display screen to adjust the appearance of your CFX 750 display Units You can display distances speeds and areas in either US Imperial or Metric format By default the display uses the US Imperial format The available units for each format are outlined below Unit US Imperial Metric Distance inches centimeters feet meters miles kilometers Speed miles per hour kilometers per hour Area acres hectares 168 CFX 750 Display User Guide System 9 Color Scheme You can adjust your color scheme according to the cab lighting and time of day For more information see Backlight page 170 This color scheme Is suitable for Day A brightly lit environment Note This is the default color scheme Dimmed Dark and low cab light environments Red Dark and low cab light environments Time Zone The GPS receiver provides UTC formerly GMT
77. d We Mia diiio detected your eireleda modem Continue to the nash ereen bo attempt to connect to the Petwork In the Wireless Modem Setup screen you can adjust the following APN Setup String SIM PIN Network username change the username used for network registration Network password change the password used for network registration CFX 750 Display User Guide 161 8 Data After you set up your modem the following screen appears Network Operational engr alulra Yu hae Oner u met up pour wireleps moden Once you receive this message you can continue with the registration process Note The internal settings for your modem are on the SIM card that your modem uses For further setup information contact your SIM card provider Network registration Register your information with the Connected Farm Network Use the username and password you created when you purchased the Connected Farm service For more information contact your Trimble reseller Connected Farm data transfer Note The Connected Farm service requires a subscription For more information on purchasing a subscription contact a Trimble reseller To configure Connected Farm operations 1 Tap P and then select Data Connected Farm Setup 2 To enable the feature select the option to turn on the Connected Farm service 162 CFX 750 Display User Guide Data 8 The setup menu now includes a number of settings as shown below If you
78. e Online Aggressiveness value Line up close to the swath and make certain that the front wheels are straight before engaging the EZ Steer system To get smoother performance when the vehicle is pulling an implement over tilled ground enable the Diff Lock This prevents the machine from pulling sharply to the left or right If you are calibrating on a hard surface turn off Diff Lock The EZ Steer system can be installed on Case IH STX tractors with Accusteer For optimal performance disable Accusteer using the switch in the cab if possible It is common for these vehicles to have slow steering To compensate for this use high aggressiveness If you experience large slow oscillations increase the aggressiveness When you configure the system on a sprayer the Sprayer steering delay setting is available on the Vehicle Setup screen Some sprayers have steering that is slow to react after you turn the steering wheel The system uses the steering delay setting to compensate for this slowness and ensure that steering corrections occur at the correct point CFX 750 Display User Guide 55 4 Vehicle Vehicle type Performance hint Swather e When you configure the system on a swather the Swather steering delay setting is available on the Vehicle Setup screen e Some swathers have steering that is slow to react after the steering wheel is turned The system uses the steering delay setting to compensate for this slowness and ensure that s
79. e ae eee 160 Mial setU c2cknanadebhenaGe eee ds teeraa GR SHAKE aaoi 160 Device NaMe 1 ee 161 Modem only setup 1 ee 161 Network registration ooo ee 162 Connected Farm data transfer oaoa a a a 162 Sending Field data using Connected Farm 1 a 163 Receiving Field data through the Connected Farm service naaa aaa a 164 Manage Dalas sssr sr r eee HRN ERE Se ewe ANERER 165 e ET E E E E E eee ee ee ee eee ee 165 Clearing the internal memory oaoa ee 166 T Sn areren reana A ua 4s 167 ModUCHON serere rs neee Aar eek eee eee ee ate e 168 DIDY ease areeee Eee a Ae ee eee a e 168 URNS eea essre nrnna renean eee eRe ee eee eee 168 COO ONEN cee ee bd ESSERE ee eee Pee Ee See 169 WMG 7ONG 2 sees G6 a ee eR ERE OES PRR SEE EH ES eae SS 169 MICW os o4 4 44 noe 6 Eee BR ee ee ea Pee ee ee eS 169 Status Popup Transparency aoaaa 170 12 CFX 750 Display User Guide Contents Ba COI rae iy tens 0 OP tee Ae oy ee OD DER ao Gus oe Gee amp OO Ae eels Be 170 Touchscreen speaker volume anaa a 170 SIE SETUD tense hak oh Sor Bf aot ere es eee eee a a es ea 170 Adya ad 4 5 rs ea a db Ak eh OS ee ee ee SS SOAS ee es A 171 Save Load Configurations n aooaa a a a a 171 Digita OUTPUT asea ae abea BMS SO a oe a a a E e e o 171 Enable Advanced User Config oa oaaae 172 NMEA OUTPUT a aaee raaa aaa bbe E Ot cece E TK ee ee ee ee S 172 EZ REMO OV SLICK e ec sh Se aa ty cee Se SS Be ere oat St i ee ee E A 173
80. e button showing the serial number of the module physically connected to that location and then tap j Set the width of the selected location Note If you have one drive only selected you will only have one Module Setup to perform and the width is then assumed to be the full implement width Select each drive in turn and complete its setup before continuing with the next drive Select the Drive Setup button showing the serial number of the first drive that you want to set up Note If you have one module only set up this screen does not appear instead the Drive Setup screen with the Valve Setup button appears CFX 750 Display User Guide 95 5 Implement Application Controller Select Options Drive Setup Valve Setup Valve Type Valve Setup D eS Fr H T Be rarna PEE ea pAn Er g E l ET L ier Plumbing 96 CFX 750 Display User Guide Description Select the Valve Type for the valve physically connected to the module The options are e Servo Standard 2 wire servo performs more slowly e Servo Fast Fast 4 wire servo performs more quickly e PWM 2 wire PWM valve commonly used to control hydraulic flow to the pump e Hardi Bypass Servo Used on Hardi sprayers equipped with 3 way section valves that return flow to the tank when the boom section is off e Pump Servo Servo valve commonly used to control hydraulic flow to the pump e Electric Over Hydraulic A valve
81. e connection to the USB drive has been lost CFX 750 Display User Guide 31 3 Getting Started Removing a USB drive N CAUTION Do not remove the USB drive from the socket while the display is writing to or from the drive This will corrupt the data 1 Rotate the display so that you can see the back of it 2 Pull the USB drive out of the USB socket Taking a screenshot Occasionally you may want to save a screenshot of the touchscreen for example to provide information for troubleshooting purposes When you take a screenshot the display saves a png file to the root directory of the USB drive Note Screenshot capability is available only when there is a USB drive inserted in the display To take a screenshot 1 Press both brightness control buttons at the same time 2 Hold the buttons down until the touchscreen flashes N CAUTION Do not remove the USB drive from the socket while the display is writing to or from the drive This will corrupt the data The Quick Start Wizard The Quick Start Wizard enables you to configure important settings before you begin driving The first time that you turn on the display the wizard starts automatically Make sure that when you first turn on the display that you run the entire wizard When you run the wizard you can choose whether or not it appears every time the display is turned on If you choose to hide the wizard the guidance screen will appear automatically w
82. e display s guidance screen Item Notes Actual rate Target rate If a prescription is loaded P displays to indicate that the prescription rate is being used rather than the target rate Boom section status Shows the current state of each boom section indicators e Green Enabled and spraying e Gray Enabled but not currently spraying e Red The section is off the switch is off Application indicator The wheel on the display spins when the Amazone master switch is on and the lightbar receives flow messages from the controller Quick Access icon See Quick Access icon page 38 LH 5000 controller Setup 1 Once you select the LH5000 as your controller the following screen appears on the display Output Port Parm A 118 CFX 750 Display User Guide Implement Application Controller 5 2 On the CFX 750 display make sure that Output Port matches the port on the display that the controller is connected to COM or AUX 3 Do not configure the display to output NMEA messages on the same port that your controller is connected to For more information on configuring the LH 5000 controller refer to the LH 5000 instruction manual Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup e Swath Control e Rate Control e Target Rate e Turn Off Rate on Overlap Rate Snapping Boom Setup Note The boom setup on the CFX 750 display must match the setup on the
83. e option that you require exit a view and return to the guidance screen tap EJ To learn how to change the View settings see View page 169 Zooming To zoom in or out on the guidance screen tap or Viewing modes There are two viewing modes Overhead and Trailing By default the view switches from Overhead to Trailing when you approach the AB line To access the Overhead view tap A l USE drive connected 36 CFX 750 Display User Guide Getting Started 3 To access the Trailing view tap 53 Extended icons The guidance screen features several extended icons that are hidden in the default view To view or hide the extended icons tap or The following images show how the extended icons appear on the guidance screen when they are expanded and collapsed Quick Acidi Guick Access Expanded Collapsed CFX 750 Display User Guide 37 3 Getting Started Quick Access icon You can use the Quick Access icon to quickly adjust common settings The items that appear in the Quick Access menu will vary depending on the AD applications that you are currently running Quick The following sections describe the items that may appear Access Note The Quick Access icon appears only when you are running Field Q or a variable rate controller Boom setup Use this option to view and adjust the following settings Value Notes Implement width Enter the width of the current
84. e recipients should know that what they have is not the original version so that the original author s reputation will not be affected by problems that might be introduced by others Finally software patents pose a constant threat to the existence of any free program We wish to make sure that a company cannot effectively restrict the users of a free program by obtaining a restrictive license from a patent holder Therefore we insist that any patent license obtained for a version of the library must be consistent with the full freedom of use specified in this license Most GNU software including some libraries is covered by the ordinary GNU General Public License This license the GNU Lesser General Public License applies to certain designated libraries and is quite different from the ordinary General Public License We use this license for certain libraries in order to permit linking those libraries into non free programs When a program is linked with a library whether statically or using a shared library the combination of the two is legally speaking a combined work a derivative of the original library The ordinary General Public License therefore permits such linking only if the entire combination fits its criteria of freedom The Lesser General Public License permits more lax criteria for linking other code with the library We call this license the Lesser General Public License because it does Less to protect the user s freedom tha
85. e vehicle is outside the configured engage limits e You pause the system e GPS positions are lost e You tap the Engage button on the guidance screen You can manually disengage the EZ Steer system by turning the steering wheel this overrides the electric motor Check this setting before you start using the system by engaging on a line and then turning the wheel until the system disengages To adjust the amount of force required to disengage the system change the Override Sensitivity in the Engage Options screen 54 CFX 750 Display User Guide Vehicle 4 Engage status indicators Engage status Ready to engage Engaged Cannot engage Icon color Curve Auto steering Accuracy in Headlands It is possible to engage the EZ Steer system on headlands with sharp corners at the edge of the field However the EZ Steer system may be unable to drive around these sharp bends Use one of the following methods to compensate Manually steer the vehicle around the corner Once you have rounded the corner re engage the EZ Steer system In the Engage Options screen increase the Disengage Offline distance Vehicle specific performance Before you use the EZ Steer system consider the following performance suggestions Vehicle type 2WD tractor AWD tractor Sprayer Performance hint With tractors that have SuperSteer for example New Holland TG if the tractor has a SuperSteer front axle for best performance Reduce th
86. e when you need to save product The system will turn off sections as soon as you reach any covered area This may leave some skips Sections will turn on when the entire section has moved from a covered to an uncovered area Choose from one of the following options e Refill to fill the tank or bin to the top e Partial Refill to add a specified amount to the tank or bin when you select Partial Refill Now from the Refill screen Use this option to refill the tank or bin Boundary switching overlap Use this option to control the amount of overlap on a boundary before the system switches off the boom section Enter a percentage between 1 99 Note This setting operates only when the boom is overlapping a headland pivot boundary or exclusion zone For e Less skip Set a high percentage when it is acceptable to apply outside the boundary e Less overlap Set a low percentage when you do not want to apply outside the boundary A very low setting may cause some skip at the boundary On off valve latency This option allows for hardware delays by adjusting the amount of time needed before turning the valves on or off To use this option 1 Measure the amount of time it takes in seconds for the system to reach the correct rate after you have switched it on or off 2 Enter atime between 0 0 10 0 seconds CFX 750 Display User Guide 39 3 Getting Started Intentional overlap You can use this option to make sure
87. ection is off the switch is off Target rate If a prescription is loaded P displays to indicate that the prescription rate is being used rather than the target rate 4 Actual rate As the HARDI controller does not report the actual applied rate to the display this item always appears as N A O Section control Shows the current mode for the controller 108 CFX 750 Display User Guide Implement Application Controller 5 Item Description Notes Fence nozzle indicator This indicator appears only when a fence nozzle is enabled Fence nozzle status is represented with the same colors as the boom sections see below Note The CFX 750 display cannot automatically turn fence nozzles on or off It only displays the current status Application indicator The wheel on the display spins when the HARDI master switch is on and the booms are on Raven controllers When using the Raven SCS 400 and 600 series controller with the CFX 750 display note the following The CFX 750 display cannot control the status of the Raven controller master or boom switches This means that the operator must remain in complete control of the sprayer at all times The CFX 750 display cannot automatically turn off the sprayer when going outside headlands across exclusion zones or previously sprayed areas The sprayer may not always switch off completely when the CFX 750 sends a zero rate This means the operator may need to manually turn off the mas
88. ection valve to turn the clutch on e Liquid Block The section control module sends power to the section valve to turn the clutch off Turn Off When Select one of the following Stopped e Yes The section closes turned off when stopped e No The section remains open turned on when stopped 92 CFX 750 Display User Guide Implement Application Controller 5 Select Options Description Section Control Module Location Set up the section grouping to match how the Section Grouping sections are physically configured on the Section Grouping implement EA ee HEr Fa Pr nr Restore Defaults Return the settings to the default Note For the default the rows are divided evenly across all sections In most applications this will be the correct setup FrEE ee EA ET L i Section 1 N Start with Section 1 and select the number of rows that are connected continue with the sections in order until all rows are assigned CFX 750 Display User Guide 93 5 Implement Application Controller Rate Control Setup Control Setup Edit Screen l Rate Control Setup y r l r Rate Control s Rate Control Module Location Drive Setup Tank Bin Setup y j r Drive Setup
89. eft Using the EZ Remote joystick Optionally you can use an EZ Remote joystick to control the CFX 750 display The joystick has ten LED buttons six have preset functions you can assign one of the following functions to each of the other four Map a rock tree or weed e Start or finish a line e Start or finish an area e Start or finish an exclusion zone e Turn coverage on or off e Camera A or Camera B control e Show trailing map view e Show overhead map view e Zoom e Show status To learn how to assign a function to a programmable button see EZ Remote joystick page 173 42 CFX 750 Display User Guide Getting Started 3 On screen icons The tables in this section describe all of the icons available on the CFX 750 display Note Icons appear only when they are appropriate They are not visible at all times To activate an icon tap it with your finger If the display does not respond when you tap it see Recalibrate touchscreen page 177 System icons System and display setup Data configuration Edit item Next page Cancel changes Back page Accept save changes Information icons Setup complete A General alert o Doo o CFX 750 Display User Guide 43 3 Getting Started View icons C erm Full screen external video Zoom in 2 Run screen trailing view Zoom out P Run screen overhead view pon pesen o Section control off Automatic section control Coverage
90. ehicle measurements are described below to learn about implement measurements see Implement Setup options page 135 Before you take the measurements position your vehicle as follows 1 Park the vehicle on level ground 2 Make sure that the vehicle is straight with the centerline of the body parallel to the wheels 3 Take the vehicle measurements To take this Measure from the measurement Wheelbase Center the axle of the front wheel to the center of the back wheel Note that the wheelbase measurement for e Tracked vehicles is exactly half of the length of the track e Articulated WD vehicles is half of the distance between the center of the front and rear wheels Antenna height Ground to the top of the GPS antenna 52 CFX 750 Display User Guide To take this measurement Antenna to axle offset Vehicle 4 Measure from the Center the axle of the front or rear wheel to the top of the GPS antenna Note Make sure that you take this measurement to within 7 6 cm 3 in as an incorrect distance may result in poor steering performance Take the measurement from the antenna to the correct point of your vehicle as follows e Rear axle MFWD Sprayer Floater Truck e Front axle 4wd tractor Combine e Track center Tracked tractor If the antenna is e in front of the axle enter a Forward distance e behind the axle enter a Behind distance T2 roll calibration
91. ernal guidance line tap to set the B point When you define the internal pattern guidance line the start point circle appears around the start point of the headland Note If you return to the start of the headland before you define a guidance line the headland will not complete 5 To complete the headland do one of the following Note Define the master line for the internal pattern before you complete the headland Drive around the rest of the headland until you return to the start point circle When you drive into the start point circle the headland completes automatically Drive part of the headland and then tap d The headland completes with a straight line from the vehicle position back to the start point Once you complete the headland the headland guidance line appears When the vehicle moves out of the headland and into the interior of the pattern the interior is populated with your selected the guidance line pattern straight AB or A FreeForm Use this pattern type to create curved and straight lines for guidance in fields of any shape The display records the exact path you drive and uses this to generate the next guidance line To select the FreeForm recording option 1 Inthe Settings screen tap Guidance and then FreeForm Recording xne 2 Tap Manual or Record with coverage CFX 750 Display User Guide 145 6 Mapping and Guidance Recording a FreeForm curve 1 Drive to the s
92. ersed Sprayer steering delay Swather steering delay Notes Enter the type of vehicle on which the EZ Steer system will be installed See Entering vehicle measurements page 52 See Entering vehicle measurements page 52 See Entering vehicle measurements page 52 Adjust the angle that the wheels turn during one full rotation of the steering wheel Enter an angle between 2 149 degrees Adjust this setting if the vehicle is consistently off to the right or left of the guidance line Enter a measurement of 0 12 0 30 48 cm Control the speed of the EZ Steer drive wheel motor Select yes or no Account for time lags with vehicle steering Enter a value between 0 1 1 5 Account for time lags with vehicle steering Enter a value between 0 1 1 5 50 CFX 750 Display User Guide Vehicle 4 Aggressiveness Use this option to view and adjust the settings described below Setting Notes Online aggressiveness Control how aggressively the EZ Steer system corrects deviations from the guidance line Enter a value between 50 150 Approach aggressiveness Control how fast the EZ Steer system steers the vehicle onto the guidance line Enter a value between 50 150 EZ Steer Demo Use this option to access the EZ Steer Demo Mode EZ Steer Demo Mode is useful for practice with defining fields coverage logging and assisted steering EZ Steer Demo Mode requires an EZ Steer controller motor and EZ Steer simulator sta
93. es you must include the copyright notice for the Library among them as well as a reference directing the user to the copy of this License Also you must do one of these things a Accompany the work with the complete corresponding machine readable source code for the Library including whatever changes were used in the work which must be distributed under Sections 1 and 2 above and if the work is an executable linked with the Library with the complete machine readable work that uses the Library as object code and or source code so that the user can modify the Library and then relink to produce a modified executable containing the modified Library It is understood that the user who changes the contents of definitions files in the Library will not necessarily be able to recompile the application to use the modified definitions b Use a suitable shared library mechanism for linking with the Library A suitable mechanism is one that 1 uses at run time a copy of the library already present on the user s computer system rather than copying library functions into the executable and 2 will operate properly with a modified version of the library if the user installs one as long as the modified version is interface compatible with the version that the work was made with c Accompany the work with a written offer valid for at least three years to give the same user the materials specified in Subsection 6a above for a charge no more th
94. esha e w eee eee SEY 27 Cleaning the touchscreen aoaaa ee 28 POWORUD 64644 FE SORE ESE RESORT EAE GEAR AEE ESSE OSS 28 Power dOWN 2 29 Resetting the display 1 esitet eIIl rruna anene DEA 30 TEU PSOE gee 8 eue eta et ahh e eee ee tt bee eee bes Gee 31 Removing a USB drive 1 k adira kaD aa ak i 32 Taking a screenshot oaoa 32 The Quick Start Wizard aoaaa eeh heb E ee eRe eT HERE ERS EERE SS 32 Using the setup wizards ooo e 33 The guidance screen 2 34 Ceil ty E E ee REO R Soe k E E E E E e 35 SCUINES Geer ee ipren Gee BEEP ESE EES GEOR PRS ORE HES 35 WIOW Gentcaeecaaeeetheeceweee ee eee OS See ee ee eee a ue 36 EXtGNGCOCONS 2 ee en ehba es ga eb ee Be ese ee ee Ae eae Ke EG Yt 37 QUICK ACCESS ICON a 44 e ce ew Ree RR eee wee Cee REG HERES Ee BSE EES 38 The Field ICOM lt 2 s kh eo eee ee ewe Kee ew ree ee eee 40 The Guidance icon 1 ee 40 The Mapping iCOn bau ee ee ee eae we HERDER Sw se ee ES EO ee Os 41 The Auto steer ICON acc ae ee ehene ne aad se tb baeeeade ean ee ee ce 41 Reading lightbar patterns ooa 41 CFX 750 Display User Guide 9 Contents Using the EZ Remote joystick oaoa a a a 42 n screen ICONS ss srera nee Rea ee Eee eeeaedeed ae en kien eens hes sea 43 4 Vehicle winds be hE K EHS RED REDE l l o 7 MUFOGUCTION 2 4 n g c48552 Ghee vedo raa bee eee eee bene eee 48 The EZ Steer assisted steering system 2 a 49 Sele ea bee ee ee E REE ee eee eee ee eee ee eee 49
95. files from a USB drive and transfer it to the internal memory The field data includes Field Boundaries Point Line and Area features Guidance lines Event data coverage Prescriptions e Send the following data from the internal memory to the USB drive Autopilot information Prescriptions Client farm and field data Retrieving data from the USB drive To transfer data from the USB drive to the internal memory 1 Inthe Manage Data screen tap USB 2 Tap Retrieve Data and then choose the data that you would like to retrieve CFX 750 Display User Guide 165 8 Data Sending data to the USB drive To transfer data from the internal memory to the USB drive 1 Inthe Manage Data screen tap USB 2 Tap Send Data to USB and then select the data to send Send Fields to USB Pred he green area Burien Co dard Eha elected files Go ERa LSO drta Note You cannot send data to a USB drive that is over 90 full For more information see The USB socket page 31 Clearing the internal memory Over time the CFX 750 display s internal memory may become full To avoid this delete files that you no longer require 1 Inthe Manage Data screen tap Internal and then Delete Data 2 Select the information to delete and then follow the wizard until the files are deleted Note If a field is currently open it will close prior to the deletion 166 CFX 750 Display User Guide System In this chapter Introdu
96. ge Sample Size Misplaced Seeds Threshold Population Adjustment Implement Application Controller 5 Description Amount of time that the row sensor population has to be above the High Alarm setting before warning Amount of time that the row sensor population has to be below the Low Alarm setting before warning Amount of time that the singulation has to be below the Singulation Alarm setting before warning Amount of time that the Seeds When Off setting is above the Seeds When Off Alarm setting before warning Amount of time that the Seeds When On is above the No Seeds When On Alarm setting before warning Amount of time that the Blockage Alarm is outside the Alarm setting before warning If no seeds fall within the percentage of theoretical seed placement it is considered a Skip If two or more seeds fall within the percentage of the theoretical seed placement it is considered a Multiple The number of seeds used to calculate the averages If seeds fall outside of this percentage from the theoretical seed placement they are considered misplaced and will reduce the spacing quality Adjusts the population reading of the seed sensors independent of the Rate Population Set the Population Adjustment Percentage Note In most cases this Adjustment setting will be 0 This feature is for Higher Population Planting CFX 750 Display User Guide 87 5 Implement Application Controller Select Options De
97. ge vehicles that take longer to turn increase the look ahead time e For 4WD articulated tractors always set the look ahead time to O seconds Look ahead time applies to LED guidance only and does not affect EZ Steer performance Set the look ahead time in seconds LED Spacing Adjust the sensitivity of the LEDs To Note The LED spacing increase sensitivity decrease the LED spacing is the distance decrease sensitivity increase the LED spacing represented by one LED LED Brightness Adjust the LED brightness for maximum visibility Main Lightbar LED Mode Select the required LED mode There are two modes to choose from e Chase Chase the lights to stay online The lights represent the swath location relative to the vehicle e Pull Center the lights to stay online The lights represent the vehicle location relative to the swath 170 CFX 750 Display User Guide Advanced System 9 Use the items in the Advanced screen to view and adjust advanced system features Advanced Save Load Configurations Once you set up your lightbar for your current job you can save the settings to a configuration file Saving a system configuration can be useful for e Quick setup when moving the display between vehicles e Quick setup when using the same vehicle but changing the implement or application e Tuning the settings for improved performance Save your improved settings e Restoring known good settings if unwanted adjustme
98. he EZ Pilot system can be installed on Case IH STX tractors with Accusteer For optimal performance disable Accusteer using the switch in the cab if possible It is common for these vehicles to have slow steering To compensate for this use high aggressiveness If you experience large slow oscillations increase the aggressiveness When you configure the system on a sprayer the Sprayer steering delay setting is available on the Vehicle Setup screen Some sprayers have steering that is slow to react after you turn the steering wheel The system uses the steering delay setting to compensate for this slowness and ensure that steering corrections occur at the correct point CFX 750 Display User Guide 69 4 Vehicle Vehicle type Performance hint Swather e When you configure the system on a swather the Swather steering delay setting is available on the Vehicle Setup screen e Some swathers have steering that is slow to react after the steering wheel is turned The system uses the steering delay setting to compensate for this slowness and ensure that steering corrections occur at the correct point e To improve the performance of your swather adjust the Swather steering delay setting by a small amount 0 1 seconds at a time Test the result between each adjustment After using the EZ Pilot system CAUTION Before you leave the vehicle turn off the power to the display which will turn off the EZ Pilot system power N CAUTION
99. he pressure gauge on the manifold reads zero and that the cooling tower is not cold to the touch This ensures that all liquid NH3 has evaporated and that the pressure is discharged Note Frost on any component is a positive indication of trapped NH3 at low pressure Lack of frost does not always indicate a lack of NH3 CFX 750 Display User Guide 7 Safety 8 CFX 750 Display User Guide Contents SAG eke eH RARER KE ROG ER RA OR 5 elaela ce 05 neLey eet eeeaedbeceea bewwe ee Oe eee ee eee 5 Working with anhydrous ammonia 2 ee ee 6 Servicing the equipment 1 7 1 introduction 26444464466 eese HERDER EK SS OH DS EE 15 APOOUTING prodi ee aeeee daha nee tee eeeee bee ese sees e ena eee 15 Related information 1 a 15 Technical assistance 45443444 koe eee ew ee wee we eS 15 2 Installing the Display and Antenna 4 c 22eee8 8 17 SYSLCIVCOMPONGNIS we ssa beh eba aa hg eS CARER SEER ERE RGSS HES 18 Installing THE GISDIAY 6 eo eae ee OAR ea EER G eee ee eee 19 Connecting the display oaoa 20 Connecting a standalone CFX 750 display for WAAS EGNOS OmniSTAR XP HP COMWCCUONS yew 6 ee eH ERS OE OE ee ee ee ee ee GS 21 Connecting a standalone CFX 750 display for RTK corrections 22 Installing the antenna aoaaa 23 3 GettingStarted et tt tt tt tt tt tt nlo 25 Display Dasi Ave ba kerknet tee ree ENEN REF tbe eRe Le 26 Front view 2 6 we ee 26 BACK VIEW fa bbou See eee ae ee eee
100. hen you turn the unit on again However you can still access the wizard at a later time as follows 1 Tap and then tap a 2 Tap Quick Start Wizard The Welcome screen appears 32 CFX 750 Display User Guide Getting Started 3 3 Tap vi The first page of the Quick Start Wizard appears Units Select jour preferred unit of arene 4 To set up your system complete each page of the wizard See the section below Using the setup wizards The CFX 750 display contains various wizards that guide you through the task of configuring your system The following table describes how to use the wizards to enter your system settings Select the setting you require The field that displays the required value When you make your selection the field changes color from gray to green Enter the numbers that you require Enter text CFX 750 Display User Guide 33 3 Getting Started Navigate the wizard See fag anir Go back to the previous page Exit the wizard Note When you exit the wizard the system retains any settings you have already selected for any settings that you have not yet entered the system uses the settings from the previous configuration Access the on screen help The guidance screen Gul oer Mapping h f Can t engage Too slow Rates ti iF Eafe T 20 0 gala A 0 0 galfa 10 Bk c a mo 4 The guidance screen displays a mix of text and icons that provide operating information
101. ible surface and perform the calibration at the normal operating speed for the vehicle For a high clearance sprayer perform the initial calibration without an implement or with the booms folded in After the initial calibration is completed you can fine tune the settings with the implement or booms folded out The calibration process requires a straight AB line If you do not create an AB line before you begin the calibration the system prompts you to open a field and create one To access the auto steer options 1 Inthe guidance screen tap P and then tap Vehicle 2 Tap Auto Steer 48 CFX 750 Display User Guide Vehicle 4 The EZ Steer assisted steering system The EZ Steer assisted steering system works with the CFX 750 display s internal GPS receiver to provide vehicle guidance As such you must complete the GPS setup before you calibrate set up or run your EZ Steer system See Chapter 7 GPS Setup To view and adjust the settings for the EZ Steer system 1 Inthe guidance screen tap P and then tap Vehicle 2 Tap Auto Steer and then EZ Steer Setup Auto Steer Note If the EZ Steer Setup button does not appear tap Auto Steer System Type and then select EZ Steer for your controller The EZ Steer Setup screen contains the following options Engage Options e Vehicle Setup e Aggressiveness EZ Steer Demo e EZ Steer Calibration Wizard The following sections describe each option CFX 750
102. ified to carry prominent notices stating that you changed the files and the date of any change c You must cause the whole of the work to be licensed at no charge to all third parties under the terms of this License d If a facility in the modified Library refers to a function or a table of data to be supplied by an application program that uses the facility other than as an argument passed when the facility is invoked then you must make a good faith effort to ensure that in the event an application does not supply such function or table the facility still operates and performs whatever part of its purpose remains meaningful For example a function in a library to compute square roots has a purpose that is entirely well defined independent of the application Therefore Subsection 2d requires that any application supplied function or table used by this function must be optional if the application does not supply it the square root function must still compute square roots These requirements apply to the modified work as a whole If identifiable sections of that work are not derived from the Library and can be reasonably considered independent and separate works in themselves then this License and its terms do not apply to those sections when you distribute them as separate works But when you distribute the same sections as part of a whole which is a work based on the Library the distribution of the whole must be on the terms of this
103. implement The display uses this value to automatically calculated the swath spacing Enter a width between 1 00 328 01 0 30 99 99 m Boundaries See Boundary setup page 133 Number of sections Enter the number of sections you want to control on the implement Enter a number between 1 10 Refill Use this option to view and adjust the following settings Setting Notes Current volume Set the current volume of the tank or bin Refill method Select from one of the following options e Refill To fill the tank or bin to the top e Partial Refill To add a specified amount to the tank or bin when you select Partial Refill Now from the Refill screen Refill Now Partial Refill Use this option to refill the tank or bin Now 38 CFX 750 Display User Guide Getting Started 3 Section Switching Setup Use this option to view and adjust the following settings Setting Coverage switching overlap Refill method Refill Now Partial Refill Now Notes Control the amount of boom switching overlap allowed before the system switches that section Enter a percentage between 1 99 For e Less skip Set a high percentage when total coverage is essential The system will turn off sections when they cover a larger percentage of any fully covered areas This may cause some double coverage Sections will turn on as soon as they move from a covered to an uncovered area e Less overlap Set a low percentag
104. ine Note AB lines are stored automatically You do not have to actively save an AB line 138 CFX 750 Display User Guide Mapping and Guidance 6 When you define the first guidance line the display copies it to create additional guidance lines Distance between guidance lines When you define the AB line you specify the width of the implement that is attached to the vehicle The display uses this measurement to calculate the distance between the guidance lines If you do not want the guidance lines to be exactly one implement width apart you can set an overlap or skip Headlands You can record a headland boundary or you can work without a headland On screen appearance When the guidance screen shows the trailing view it tags the guidance lines with the following icons These icon s Are tagged to AB The master line that you created The swaths are based on this line The first swath to the left of the master line where left is relative to the direction the L1 master line was drawn not the vehicle s current position Note the following The A start and B end point on the master line e The current swath and tag are orange e Ona Pivot pattern the swaths are numbered out from the center not from the initial swath La The second line to the left of the master line Guidance Patterns Select a guidance pattern that enables you to create a guidance line to suit your field 1 From the
105. lement width Enter a width between 1 00 328 01 0 30 99 99 m Number of sections Enter anumber between 1 10 Target Rate Set the target application rate that will be sent to the Raven controller Enter a rate between 0 0 11000 0 110 CFX 750 Display User Guide Implement Application Controller 5 Rate Snapping Due to pump constraints liquid flow is generally inconsistent To control how these inconsistencies appear on your display turn rate snapping on or off Setting Notes On Matches the applied rate to the target rate when within 10 of the value Off Shows all fluctuations in the actual applied rate Operation When you connect the Raven controller to the CFX 750 display the following items appear on the guidance screen Gul deer Migging ys itis Can t engage Too slow Aatevie ct ead a T 20 0 gala A 0 0 galfa Bk A as Item Description Notes Quick Access icon See Quick Access icon page 38 Boom section status Shows the current state of each boom section indicators e Green Enabled and spraying e Gray Enabled but not currently spraying e Red The section is off the switch is off Target rate If a prescription is loaded P displays to indicate that the prescription rate is being used rather than the target rate Actual rate The actual application rate This is the amount of product that is currently being applied Application indicator The wheel on the display spins when
106. les shp dbf and shx Each of these files contain different attribute information that the display uses You must load a prescription from the USB drive to the internal memory of the CFX 750 display The display cannot read prescriptions directly from a USB drive For more information see the section below Loading a prescription 1 Copy the prescription file from your computer to the AgGPS Prescriptions folder on your USB drive Note If you do not have an AgGPS directory on your USB create one by exporting field data to the USB For more information see Sending data to the USB drive page 166 2 Insert the USB drive into the USB socket and then copy the prescription file to the display s internal memory See Retrieving data from the USB drive page 165 3 From the guidance screen tap to create a new field or select an existing field The CFX 750 display searches the internal memory for prescription files and after you define or select a field the following screen appears in the wizard Available Prescriptions List Hote CFX 750 Display User Guide 75 5 Implement Application Controller 4 Select the prescription file that you require and then tap pa The following screen appears Prescription Parameters Egi setting by prasaig dith one individuality Press Che preen accept button Ca Core ira 5 Configure each of the items in the Prescription Parameters screen N CAUTION For
107. logging on 44 CFX 750 Display User Guide Guidance icons Pause guidance Nudge left a Nudge right Record FreeForm guidance pattern Shift AB line Next AB line Mapping icons Map rock point feature Getting Started 3 Start recording headland Pause recording headland End headland recording Cannot engage auto guidance Ready to engage auto guidance Auto guidance engaged Increase auto guidance aggressiveness Decrease auto guidance aggressiveness Mapping configuration Area feature CFX 750 Display User Guide 45 3 Getting Started 46 CFX 750 Display User Guide Vehicle In this chapter This chapter describes how to configure your auto steer system for use with the CFX 750 m Introduction display m The EZ Steer assisted steering system m The EZ Pilot steering system m The Autopilot automated steering system CFX 750 Display User Guide 47 4 Vehicle Introduction To ensure the correct performance of your auto steer system you must calibrate it correctly Before you calibrate your auto steer option do the following e Ensure that the vehicle s hydraulic oil is up to operating temperature Refer to the vehicle documentation e Ensure that the tire pressure is correct e Complete the GPS Setup on the CFX 750 display For more information see Chapter 7 GPS When you calibrate your auto steer option pay attention to the following e Choose a field with the smoothest poss
108. mapping the AB line on a road down the side of the field skipping an access road in a field 140 CFX 750 Display User Guide Mapping and Guidance 6 The A line extends 1 km 0 6 miles before and after the A point Mapping an A line 1 Drive to the start point of the master line 2 Tap amp and then drive to the end of the line Because you have already set the line heading the master AB line appears on the screen 3 For guidance down the first swath follow the AB line 4 Turn left or right for the next swath As you move toward the next swath it appears on the screen and turns orange to show that it is selected Identical curve The identical curve pattern records your exact route between the A and B points instead of creating a straight line All subsequent guidance lines will match the master curve regardless of where you drive the vehicle Use the identical curve pattern when you want to work a field with gentle curves Mapping an identical curve 1 Drive to the start point of the curve 2 Tap and then drive the initial curve 3 When the icon is highlighted tap B The master curve appears on the screen 4 Turn left or right for the next swath As you move toward the next swath it appears on the screen and turns orange to show that it is selected Adaptive curve The adaptive curve pattern provides guidance along a curve and updates guidance after each swath to take into account any deviations y
109. n Working with anhydrous ammonia page 6 For information on installing the Field IQ crop input control system on your implement refer to e Field IQ Platform Installation Instructions Tru Count Air Clutch Installation Instructions e Rawson Installation Instructions For the latest versions of these documents go to www trimble com agriculture Setting up the Field IQ system Setting up the Implement and Control type 1 Inthe guidance screen tap ge 2 Inthe Settings screen tap Implement 78 CFX 750 Display User Guide Implement Application Controller 5 3 Inthe Implement screen tap Initial Setup Note When you are setting the system up for the first time this is the only button that appears However if you have previously installed the Field IQ system more options will appear 4 inthe Controller Type screen tap Field IQ and then tap vi A Summary screen appears that shows all the Field IQ components with their serial numbers detected by the display To continue tap ES Field IQ Hardware Summary EF Master Saitoh Module feria Murber Co Switch Centra Haedui Serial Murnber Rate and Section Control Module Peoria Mumber Rate and Section Contre Module Setting up the Implement Operation and Implement Layout 1 Inthe mplement Type screen tap Implement Operation Implement Type Edit settings ey Deda Hh ore Press Che preen accept button t cere rae 2 Inthe Im
110. n adaptive curve You must record your line on each pass to receive guidance on the next If the vehicle is not drawing a line or guidance trail behind it you are not recording your path and therefore the next guidance line will not appear Note Do not confuse the existing guidance line with the guidance trail appearing behind the vehicle that shows your current guidance You need to create a new guidance line to receive guidance on the next pass Using guidance on straight segments When driving on straight AB lines you do not have to record your path because the guidance lines are generated automatically Creating straight sections on Headland or Curve swaths To create straight sections when recording headland or curve swaths 1 Tap SU 2 Drive the section 3 Tap So to finish recording the straight section and to start recording a curve again Fields A field is specific area of land where events such as planting seed or applying fertilizer are carried out You create your first field when you first configure your implement see Starting Guidance page 134 That field remains open until you do one of the following e Create a new field or load a previously saved field e Calibrate your EZ Steer system e Perform a hard reset Note Fields are stored automatically You do not have to actively save a field The following sections describe how to use the field function when there is already a field currently l
111. n the ordinary General Public License It also provides other free software developers Less of an advantage over competing non free programs These disadvantages are the reason we use the ordinary General Public License for many libraries However the Lesser license provides advantages in certain special circumstances For example on rare occasions there may be a special need to encourage the widest possible use of a certain library so that it becomes a de facto standard To achieve this non free programs must be allowed to use the library A more frequent case is that a free library does the same job as widely used non free libraries In this case there is little to gain by limiting the free library to free software only so we use the Lesser General Public License In other cases permission to use a particular library in nonfree programs enables a greater number of people to use a large body of free software For example permission to use the GNU C Library in non free programs enables many more people to use the whole GNU operating system as well as its variant the GNU Linux operating system Although the Lesser General Public License is Less protective of the users freedom it does ensure that the user of a program that is linked with the Library has the freedom and the wherewithal to run that program using a modified version of the Library The precise terms and conditions for copying distribution and modification follow Pay close
112. nd P N 54836 00 EZ Steer Calibration Wizard The EZ Steer Calibration Wizard guides you through the process of calibrating your EZ Steer system Calibration Before you begin to use the display you must calibrate the EZ Steer system To do this complete the Quick Start Wizard see The Quick Start Wizard page 32 that appears the first time that you use the display Note You must have GPS connected To calibrate the EZ Steer system at a later time complete the following process 1 Inthe guidance screen tap Se and then tap Vehicle 2 Tap Auto Steer and then tap EZ Steer Setup Auto Steer CFX 750 Display User Guide 51 4 Vehicle Note If the EZ Steer Setup button does not appear tap Auto Steer System Type and then select EZ Steer for your controller 3 Inthe EZ Steer Setup screen tap EZ Steer Calibration Wizard The wizard guides you through the following processes Entering your vehicle measurements 72 roll calibration z EZ Steer calibration Entering vehicle measurements For optimum guidance you must take accurate vehicle measurements and enter them into the display Note Do not enter calibration numbers from EZ Guide Plus or EZ Steer T2 systems This may cause very poor vehicle control including swerves and or large oscillations To streamline the calibration process you may want to take the vehicle measurements and record them for entry later on The techniques for taking v
113. nded to 101 CFX 750 Display User Guide 123 5 Implement Application Controller Target Rate Set the target application rate that will be sent to the LH 5000 controller Enter a rate between 0 0 11000 0 Single section boom switching Use this to turn off the implement in areas that have already been applied Note This setting can only turn the entire boom on and off It does not support individual sections Select Yes to avoid spraying an area that has previously been sprayed Select No to spray an area that has previously been sprayed Rate Snapping Due to pump constraints liquid flow is generally inconsistent To control how these inconsistencies appear on your display turn rate snapping on or off Value Notes On Matches the applied rate to the target rate when within 10 of the value Off Shows all fluctuations in the actual applied rate Bogballe controller Setup 1 Once you select Bogballe as your controller the following screen appears on the display Output Port Part A Note Do not configure the display to output NMEA messages on the same port that your controller is connected to 124 CFX 750 Display User Guide Implement Application Controller 5 2 Onthe Bogballe controller press Return Return Fertil Distrib Select Type Bogballe E EX Accept For more information on setting up the Amazone controller refer to the Amazone instruction manual Advanced Use
114. njury or damage Note An absence of specific alerts does not mean that there are no safety risks involved WARNING Anhydrous ammonia NH3 can cause severe burning blindness or death Before you begin to operate or service equipment that contains NH3 carefully read and follow all safety instructions in Working with anhydrous ammonia page 6 WARNING Incorrect adjustment of the Manual Override Sensitivity calibration setting could cause this critical safety feature to fail resulting in personal injury or damage to the vehicle Any adjustment to this setting should only be made by an experienced user WARNING During the Deadzone calibration the system moves the vehicle s steering wheels To avoid injury be prepared for sudden vehicle movement WARNING When you tap the liquid flow calibration Start button the machine will become operational Take all necessary precautions to ensure user Safety Failure to do so may result in serious injury or death WARNING When you tap the control valve calibration Start button the machine will become operational Take all necessary precautions to ensure user safety Failure to do so may result in serious injury or death CFX 750 Display User Guide 5 Safety gt D WARNING When you tap the fill disk Start button the machine becomes operational Take all necessary precautions to ensure user safety Failure to do so may result in serious injury or death WA
115. nt switch See Field IQ master switch box page 104 Required for section control Manually control sections rows See Field IQ 12 section switch box page 105 Controls 12 sections rows per module with up to 4 modules 48 module sections rows Controls 12 sections and application rate for spraying spreading and NH3 Controls 1 Rawson variable rate drive per module with up to 4 modules Included in planter NH3 and strip till platform kits Units of measure Type Seed Granular seed Unit Metric US Imperial Metric US Imperial Symbol kS ha kS a kg ha lbs a Description Thousands of seeds per hectare Thousands of seeds per acre Kilograms of seed per hectare Pounds of seed per acre CFX 750 Display User Guide 77 5 Implement Application Controller Type Unit Symbol Description Liquid application Metric L ha Liters per hectare US Imperial Gal a Gallons per acre Granular fertilizer Metric kg ha Kilograms of fertilizer per hectare US Imperial lbs a Pounds of fertilizer per acre NH3 Metric kg NH3 Kilograms of anhydrous per hectare US Imperial lbs NH3 Pounds of anhydrous per acre Metric kg N Kilograms of nitrogen per hectare US Imperial Ibs N Pounds of nitrogen per acre Installing the Field IQ hardware N WARNING Anhydrous ammonia NH3 can cause severe burning blindness or death Before you begin to operate or service equipment that contains NH3 carefully read and follow all safety instructions i
116. nter a distance between 0 00 32 10 0 00 10 00 m Rate control Use this option to view and adjust the following settings Setting Notes On Application rates are sent from a prescription loaded in the display or the target rate manually configured on the display Off The target rate must be set on the LH 5000 controller The CFX 750 display does not send target rates to the controller This is the default setting Note When sending a target rate to the LH 5000 controller that is higher than 99 9 the display rounds to the nearest whole number For example 0 99 9 is not rounded 101 4 is rounded to 101 Target Rate Set the target application rate that will be sent to the LH 5000 controller Enter a rate between 0 0 11000 0 Single section boom switching Use this to turn off the implement in areas that have already been applied Note This setting can only turn the entire boom on and off It does not support individual sections e Select Yes to avoid spraying an area that has previously been sprayed e Select No to spray an area that has previously been sprayed Checking the implement connection To check that the CFX 750 display and your implement controller are communicating correctly access the VR Controller Status screen 1 Inthe Settings screen tap Vehicle and then tap Status 126 CFX 750 Display User Guide Implement Application Controller 5 Tap VR Controller Status A screen similar
117. nter an obstacle in the field continue to record your path as you drive around it On the next pass the guidance line will adjust to reflect this Note When you create a spiral with the Freeform guidance pattern there may be a space at the center of the spiral 146 CFX 750 Display User Guide Mapping and Guidance 6 Using FreeForm curves in fields with variable terrain Start and stop recording guidance at the ends of each pass If there are two guidance lines in close proximity tap Ite to snap to the correct line At any point you can add a straight AB line for repeated straight line guidance Tap Ike to switch between straight AB and FreeForm curve guidance lines Coverage logging Coverage logging draws a solid block of color behind the vehicle to show the area that you have applied When you pass over an area for the second time the color of the covered area changes This is useful for viewing overlaps To begin coverage logging tap E while you are driving to finish coverage logging tap Note There may be a delay between the time you start or stop coverage logging onscreen and the time the implement actually starts or stops coverage To compensate for this you can add a time delay to the drawing of coverage logging See Coverage on off delay page 132 Note Field coverage is limited to 1000 acres for each event The pause resume function When you tap Pause yo an icon appears on the screen to show your exa
118. nter pivot irrigation With this pattern you can drive concentric circles around the center pivot To map a pivot Note Always set the master line near the outer edge of the field 1 Drive to the start point of the pivot 2 Position one wheel of the vehicle in a pivot wheel rut with the rear of the vehicle to the pivot arm If the field is not a full circle pivot face the rear of the vehicle to the edge of the field 3 Tap A and then drive around the field Keep the vehicle in the rut The display will generate guidance swaths 142 CFX 750 Display User Guide Mapping and Guidance 6 Turn left or right for the next swath As you move toward the next swath it appears on the screen and turns orange to show that it is selected Steer the vehicle so that the lit LEDs are centered on the lightbar as you drive forward along the swath CFX 750 Display User Guide 143 6 Mapping and Guidance Headland The headland pattern enables you to define the boundary headland of the area as well as the guidance lines contained within it Use the headland pattern to allow room to turn The following diagrams show the two headland patterns Single Multiple When you start to define the headland you define the internal guidance line as you drive around the headland and then you complete the headland You can change two settings for the headland pattern e The number of circuits e The internal pattern Number of circuits
119. nts have been made Digital Output The CFX 750 display can generate a digital signal on pin 2 of Port A Note Additional equipment may be required to properly use the Digital Output function To use speed pulse output you need a radar sensor cable kit that includes a pulse amplifier adapter Contact your local reseller Use this setting Disabled Radar Remote Output To Disable digital output on pin 2 of Port A Output simulated radar pulses at a pre defined speed pulse output rate This can be useful to e Replace the radar true ground speed sensor for speed on the vehicle e Send speed to any other agricultural device requiring speed pulses such as a yield monitor or variable rate controller Note After you select Radar set the radar frequency rate from the Digital Output screen Output a signal whenever auto steering is engaged This can be useful to drive a switch or relay for equipment that should be active when engaged CFX 750 Display User Guide 171 9 System Enable Advanced User Config N CAUTION Do not use the Enable Advanced User Config feature unless you have the support of a Trimble Reseller Altering any of the settings for this feature may cause system failure NMEA Output NMEA National Marine Electronics Association messages are a standard format that GPS devices use to communicate The CFX 750 display can output NMEA messages to communicate with other NMEA compatible devices In the NM
120. o indicate that the prescription rate is being used rather than the target rate The actual application rate This is the amount of product that is currently being applied The wheel on the display spins when the LH 5000 master switch is on and the lightbar receives flow messages from the controller CFX 750 Display User Guide 121 5 Implement Application Controller Vaderstad Setup 1 Once you select Vaderstad as your controller the following screen appears on the display Output Port Part A Note Do not configure the display to output NMEA messages on the same port that your controller is connected to 2 Inthe Device Type screen select the type of implement you are using Sprayer Planter Seeder Fertilizer Spreader 3 Onthe Vaderstad controller go to the setup screen 4 Set GPS to No Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup Swath Control Rate Control Target Rate Single section boom switching Rate Snapping 122 CFX 750 Display User Guide Implement Application Controller 5 Boom Setup Note The boom setup on the CFX 750 display must match the setup on the LH 5000 controller If the boom setup differs between the display and the LH 5000 controller a warning message appears on the display Use this option to view and adjust the following settings Setting Notes Implement width Enter a width between 1 00 328 0
121. oaded on the display 136 CFX 750 Display User Guide Mapping and Guidance 6 Creating a new field ff In the guidance view tap The Finished with Field screen appears Tap Yes In the Create New or Select Old Field screen tap Create New Field To setup the new field progress through the wizard Follow the on screen instructions to drive your new line For more information see Mapping an AB line page 140 Selecting loading a field Se eS eS In the guidance view tap The Finished with Field screen appears In the Finished with Field screen tap Yes In the Create New or Select Old Field screen tap Select Field by Name In the Select Field by Name screen select the field you wish to load To set up the field progress through the wizard Adding an AB line to a current field To create a new AB line in a current field 1 2 3 4 5 In the guidance view tap The Finished with Field screen appears In the Finished with Field screen tap No In the Create New or Select Old Swath screen tap Add AB Line To set up the new field progress through the wizard Follow the on screen instructions to drive your new line For more information see Mapping an AB line page 140 Selecting loading an AB line into a field amp S In the guidance view tap The Finished with Field screen appears In the Finished with Field screen tap No In the Create New or Select Old Swath screen tap Selec
122. on your display turn rate snapping on or off Setting Notes On Matches the actual applied rate to the target rate when within 10 of the value Off Shows all fluctuations in the actual applied rate Operation 114 CFX 750 Display User Guide Item Implement Application Controller 5 When you connect the Rawson controller to the display the following items appear on the CFX 750 guidance screen i G y E 4 irllines al dae ys ali Can t engage Too slow gra T 20 0 gal a A 0 0 gala Ek A ae 3 4 Description Notes Quick Access icon See Quick Access icon page 38 Boom section status Shows the current state of each boom section indicators e Green Enabled and spraying e Gray Enabled but not currently spraying e Red The section is off the switch is off Target rate If a prescription is loaded P displays to indicate that the prescription rate is being used rather than the target rate Actual rate The actual application rate This is the amount of product that is currently being applied Application indicator The wheel on the display spins when the Rawson master switch is on and the lightbar receives flow messages from the controller CFX 750 Display User Guide 115 5 Implement Application Controller Amazone controller 116 Setup 1 Once you select Amazone as your controller the following screen appears on the display Output Port Part A Note Do not configure
123. open_source FmxX This software includes the DejaVu fonts which are licensed under the Bitstream Vera license terms available at http dejavu fonts org wiki index php title License and http www gnome org fonts GNU LESSER GENERAL PUBLIC LICENSE Version 2 1 February 1999 Copyright c 1991 1999 Free Software Foundation Inc 51 Franklin Street Fifth Floor Boston MA 02110 1301 USA 2 CFX 750 Display User Guide Everyone is permitted to copy and distribute verbatim copies of this license document but changing it is not allowed This is the first released version of the Lesser GPL It also counts as the successor of the GNU Library Public License version 2 hence the version number 2 1 Preamble The licenses for most software are designed to take away your freedom to share and change it By contrast the GNU General Public Licenses are intended to guarantee your freedom to share and change free software to make sure the software is free for all its users This license the Lesser General Public License applies to some specially designated software packages typically libraries of the Free Software Foundation and other authors who decide to use it You can use it too but we suggest you first think carefully about whether this license or the ordinary General Public License is the better strategy to use in any particular case based on the explanations below When we speak of free software we are referring to freedom of use not
124. ou make It continually records your path and provides guidance that matches the last path you drove Mapping an adaptive curve You can map an adaptive curve either manually or automatically The method you use depends on the Auto U turn detection setting To change the Auto U turn detection setting 1 Inthe Settings screen tap Guidance CFX 750 Display User Guide 141 6 Mapping and Guidance 2 Tap Turn Settings then Auto U Turn Detection 3 Ifyou want to map the adaptive curve Automatically select On Manually select Off To map an adaptive curve with automatic turn detection 1 Drive to the start point of the curve 2 Tap and then drive the initial curve 3 Atthe end of the first curve perform a U turn The system detects the turn and generates the next swath To map an adaptive curve manually 1 Drive to the start point of the curve 2 Tap A and then drive the initial curve 3 Atthe end of the first curve tap B The system generates the next swath 4 Continue to drive the swaths setting the B point at the end of each one Using the adaptive curve pattern for row finding 1 Set Auto U Turn Detection to Off 2 Create a guidance line based on the adaptive curve pattern 3 Set the B point at the end of each row 4 Turn the vehicle toward the next swath When the vehicle is halfway through the turn guidance along the next swath appears Pivot Use the pivot pattern on fields that use ce
125. ough the source code is not Whether this is true is especially significant if the work can be linked without the Library or if the work is itself a library The threshold for this to be true is not precisely defined by law If such an object file uses only numerical parameters data structure layouts and accessors and small macros and small inline functions ten lines or less in length then the use of the object file is unrestricted regardless of whether it is legally a derivative work Executables containing this object code plus portions of the Library will still fall under Section 6 Otherwise if the work is a derivative of the Library you may distribute the object code for the work under the terms of Section 6 Any executables containing that work also fall under Section 6 whether or not they are linked directly with the Library itself 6 As an exception to the Sections above you may also combine or link a work that uses the Library with the Library to produce a work containing portions of the Library and distribute that work under terms of your choice provided that the terms permit modification of the work for the customer s own use and reverse engineering for debugging such modifications You must give prominent notice with each copy of the work that the Library is used in it and that the Library and its use are covered by this License You must supply a copy of this License If the work during execution displays copyright notic
126. ower it on 2 Wait until the status bar at the bottom of the second startup screen is over half full 3 Press the power button and both brightness control buttons at the same time 4 Hold the buttons down until the display beeps 30 CFX 750 Display User Guide Getting Started 3 The USB socket The USB socket is on the rear of the display See Back view page 27 Use the USB socket to manage your data via a USB drive USB drive compatibility You can use the following USB drives with the CFX 750 display e A Data micro SDHC SD USB adapter e ADATA Classic C801 8 GB e Digital Concepts USB to PC Reader e Generic USB uDHC adapter with Transcend 8 GB microSDHC card e Kingston Data Traveler 8 GB e Kingston Data Traveler 101 e Lexar Firefly 1 GB e Lexar JumpDrive TwistTurn e Lexar Secure II Plus e PNY Attache e PNY Micro Swivel Attache 4 GB e PNY Mini Attache 4 GB e PNY Mini Attache 8 GB e SanDisk Cruzer e SanDisk Cruzer Gator 4 GB e SanDisk Cruzer Micro 1 GB e Toshiba TransMemory U2M 004GTA 4GB Transcend JetFlash Inserting a USB drive 1 Rotate the display so you that can see the back of it 2 Insert the USB drive into the USB socket When the USB drive is inserted correctly the USB icon appears on the guidance screen Orive 160 ft to set B point The color of the USB icon indicates the current state of the USB drive 7 Green the USB drive is connected Yellow the USB drive is connecting Red th
127. play User Guide 155 8 Data Introduction In the Connected Farm server use the options in the Data menu to Save and retrieve fields from the USB drive Send fields via Connected Farm to your home or office computer Delete fields and coverage logging Export diagnostic log files to the USB drive for technical support purposes Copy prescriptions from the USB drive to the internal memory and delete from the internal memory To access the Data menu I 2 From the guidance screen tap P From the Settings screen select Data The following screen appears DCM 300 modem This section describes how to set up a DCM 300 modem for use with VRS corrections Passcodes The DCM 300 modem requires a passcode upgrade to use VRS and Connected Farm functions VRS and Sync File Transfer functions in the DCM 300 modem must be unlocked to begin using VRS corrections or transferring data 156 CFX 750 Display User Guide Data 8 To unlock the modem with a passcode 1 Turn onthe modem and then connect it to the display s USB port 2 Select the Wrench icon and then select System Unlock Upgrade Unlock Upgrade 3 Enter the passcode When prompted select Yes to restart the modem Enter Lockcode 59380 TRGI1 00000 29134ECS Booceouooo ES000ee00 ae Ce T The DCM 300 modem will be ready to use after approximately three minutes Unlock DCM300 BA Corse itiuiateceal YT co DX ee ie EFESE H To
128. plement Operation screen tap the required operation and then tap vi Implement Operation Hote CFX 750 Display User Guide 79 5 Implement Application Controller 4 In the Implement Type screen tap Implement Layout The options that you can select depend on the operation you selected The options are Implement Operation Implement Layout options Spreading Pull type spreader Spreader truck Spraying Front sprayer Rear sprayer Pull type sprayer Planting Standard Tillage Tillage Once you select both the Implement Operation and the Implement Layout tap C3 Setting up the Implement Measurements 1 Tap In the Implement Measurements screen tap each option in turn to enter the measurements for your implement Implement Measurements Edit g each Pea Press bhe greeni accept button t Conk ira Once you enter the required measurements in a settings screen tap to return to the Implement Measurement screen and select the next option For the best performance physically measure your implement and enter accurate values for each setting The options are Description Number of Rows Number of rows covered by the implement Row Spacing Spacing between the rows 80 CFX 750 Display User Guide Tap Overlap Skip Implement Width Left Right Offset Forward Back Offset Hitch to Ground Contact Point Implement Application Controller Description The amount of overlap or skip bet
129. plus any associated interfacedefinition files plus the scripts used to control compilation and installation of the library Activities other than copying distribution and modification are not covered by this License they are outside its scope The act of running a program using the Library is not restricted and output from such a program is covered only if its contents constitute a work based on the Library independent of the use of the Library in a tool for writing it Whether that is true depends on what the Library does and what the program that uses the Library does 1 You may copy and distribute verbatim copies of the Library s complete source code as you receive it in any medium provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty keep intact all the notices that refer to this License and to the absence of any warranty and distribute a copy of this License along with the Library You may charge a fee for the physical act of transferring a copy and you may at your option offer warranty protection in exchange for a fee 2 You may modify your copy or copies of the Library or any portion of it thus forming a work based on the Library and copy and distribute such modifications or work under the terms of Section 1 above provided that you also meet all of these conditions a The modified work must itself be a software library b You must cause the files mod
130. r at least five gallons readily available In case of exposure flush exposed skin or eyes immediately with large quantities of water and seek immediate medical attention 6 CFX 750 Display User Guide Safety NH3 can be harmful to the environment if not used correctly Follow all local state and federal regulations regarding proper handling of this chemical Servicing the equipment 1 2 Remove the system from operation before performing any maintenance Thoroughly bleed all system lines and disconnect the nurse tank hose See Discharging the system page 7 Make sure that the gauge pressure is at zero before you open the system Use extreme caution when opening a previously pressurized system Discharging the system 1 e 2 et p pA 10 Turn off the console or vehicle master switch Completely close the main shut off valve on the supply or nurse tank Resume field application until the pressure gauge shows zero pressure Check again that the console and or vehicle master switch and all section switches are turned off Completely close the emergency shut off valve the cooling tower Bleed and disconnect the nurse tank supply hose from the system Turn on the console master switch and all section switches Stand up wind from the implement and then slowly open the bleed valve s until fully open Allow at least one 1 hour for the system to fully discharge Before you open the system make sure that t
131. r Guide Implement Application Controller 5 Use this option to view and adjust the following settings Setting Implement width Fence Nozzles Number of sections Swath Control Notes Enter a width between 1 00 328 01 0 30 99 99 m Enter the locations of any fence nozzles Enter a number between 1 10 Use this option to view and adjust the following settings Setting Boom control Coverage switching overlap Boundary switching overlap On Off valve latency Intentional overlap Rate control Notes Enter a width between 1 00 328 01 0 30 99 99 m Control the amount of boom switching overlap allowed before the section will be switched by the system Enter a value between 1 99 Control the amount of overlap on a boundary before the boom section is switched off Enter a value between 1 99 Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area Enter a distance between 0 00 32 10 0 00 10 00 m Use this option to view and adjust the following settings Setting Notes On Application rates are sent from a prescription loaded in the display or the target rate manually configured on the display Off The target rate must be set on the HARDI controller The CFX 750 display does not send target rates to the controller This i
132. rcial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits TRIMBLE is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Responsible Party Trimble Navigation 935 Stewart Drive Sunnyvale CA 94085 Telephone 1 408 481 8000 Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada This apparatus complies with Canadian RSS GEN RSS 310 RSS 210 and RSS 119 Cet appareil est conforme a la norme CNR GEN CNR 310 CN
133. re are not modified or misused The preceding warranties shall not apply to and Trimble shall not be responsible for defects or performance problems resulting from i the combination or utilization of the Product or Software with hardware or software products information data systems interfaces or devices not made supplied or specified by Trimble ii the operation of the Product or Software under any specification other than or in addition to Trimble s standard specifications for its products iii the unauthorized installation modification or use of the Product or Software iv damage caused by accident lightning or other electrical discharge fresh or salt water immersion or spray outside of Product specifications or v normal wear and tear on consumable parts e g batteries Trimble does not warrant or guarantee the results obtained through the use of the Product or that software components will operate error free THE WARRANTIES ABOVE STATE TRIMBLE S ENTIRE LIABILITY AND YOUR EXCLUSIVE REMEDIES RELATING TO THE PRODUCTS AND SOFTWARE EXCEPT AS OTHERWISE EXPRESSLY PROVIDED HEREIN THE PRODUCTS SOFTWARE AND ACCOMPANYING DOCUMENTATION AND MATERIALS ARE PROVIDED AS IS AND WITHOUT EXPRESS OR IMPLIED WARRANTY OF ANY KIND BY EITHER TRIMBLE NAVIGATION LIMITED OR ANYONE WHO HAS BEEN INVOLVED IN ITS CREATION PRODUCTION INSTALLATION OR DISTRIBUTION INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND F
134. roduct that is currently being applied O Row monitoring bar D Sensor Information Shows current information for the selected sensors 12 Cycle button Available if you have more than 12 rows to view Field IQ master switch box Feature Function 1 Increment decrement Increases the applied amount by a set amount the amount set in the switch Setup screen Rate tab Rate switch Choose to use preset Rate 1 preset Rate 2 or Manual rate LED indicator Red Unit is powered but not communicating with the CFX 750 display Green Unit is powered and communicating with the CFX 750 display Yellow Unit is initializing communications with the CFX 750 display 4 Automatic Manual Automatic mode The CFX 750 display automatically opens and closes section switch sections when entering areas of overlap non apply zones or crossing boundaries Manual mode The sections are controlled manually bypassing the CFX 750 display You can switch from Automatic to Manual mode while traveling Master switch e A Jump start top position The sections and rate are ready to be commanded by the CFX 750 display and the system is overridden to use a preset control speed the speed is set in the Setup screen Override tab Use the jump start function if you lose a GPS signal or you want to start applying before your implement is up to speed e B On middle position The sections and rate are ready to be commanded by the CFX 750 display e C
135. s and enter them into the display Note Do not enter calibration numbers from EZ Guide Plus or EZ Steer systems This may cause very poor vehicle control including swerves and or large oscillations To streamline the calibration process you may want to take the vehicle measurements and record them for entry later on The techniques for taking vehicle measurements are described below to learn about implement measurements see Implement Setup options page 135 Before you take the measurements position your vehicle as follows 1 Park the vehicle on level ground 2 Make sure that the vehicle is straight with the centerline of the body parallel to the wheels Take the vehicle measurements To take this Measure from the measurement Wheelbase Center the axle of the front wheel to the center of the back wheel Note that the wheelbase measurement for tracked vehicles is exactly half of the length of the track Antenna height Ground to the top of the GNSS antenna CFX 750 Display User Guide 59 4 Vehicle To take this Measure from the measurement Antenna to axle Center the axle of the front or rear wheel to the top of the GPS offset antenna Note Make sure that you take this measurement to within 7 6 cm 3 in as an incorrect distance may result in poor steering performance Take the measurement from the antenna to the correct point of your vehicle as follows e Rear axle MFWD
136. s the default setting Note When sending a target rate to the HARDI 5500 controller that is higher than 99 9 the display rounds to the nearest whole number For example 0 99 9 is not rounded 101 4 is rounded to 101 Off When Stopped You can use this option to control whether the system allows the vehicle to continue operating when it is not moving If the vehicle is a clutch operated planter select No so you can continue planting even when stopped CFX 750 Display User Guide 107 5 Implement Application Controller Rate Snapping Due to pump constraints liquid flow is generally inconsistent To control how these inconsistencies appear on your display turn rate snapping on or off Value Notes On Matches the applied rate to the target rate when within 10 of the value Off Shows all fluctuations in the actual applied rate Operation When you connect the HARDI 5500 controller to the CFX 750 display the following items appear on the guidance screen oroimenik lt U H a oi gt Jili Y Settings Guid amie Pe Zz Mapping ie D oh ioc Can t engage Too slow oita Sup T 20 0 gal a Q Txe A 0 0 gala 1B Bi g E m 5 N 3 5 Item Description Notes 1 Quick Access icon See Quick Access icon page 38 2 Boom section status Shows the current state of each boom section indicators e Green Enabled and spraying e Gray Enabled but not currently spraying e Red The s
137. scription Operation Setup Jump Start Speed The speed that the control system will use when the Operation Setup master switch is held in the Jump Start Position EA FHI E ee ER a Para ea Note The Rate Switch has to be in Position 1 or 2 for the Jump Start Feature to work Shutoff Speed The system will shut down if the vehicle drops below this speed Minimum The system will continue to run at this speed if the Override Speed vehicle drops below this speed Apply Latency to e Yes The system starts when needed to begin Boundary applying immediately when crossing a boundary e No The system starts when the boundary is reached and any mechanical delay could leave a gap between the boundary and where the product is applied When GPS accuracy is low this is the preferred selection Note This setting only applies to fields that have a boundary Note This setting is also applied when you exit an exclusion zone and return to the workable area of the field Rate Snap e Enabled Shows the Applied Rate the same as the Target Rate when the Applied Rate is within 10 of the Target Rate e Off Shows the actual Applied Rate Once you complete all the Material Type options tap to return to the Material Setup screen Note Once you tap in the Operation Setup screen the setup of this material is complete The Material Setup screen now shows New Material and Delete All buttons and a list of the materials you have set
138. signals The display can also use an array of components to maximize efficiency when planting spraying spreading and strip tilling including the Trimble Field lIQ crop input control system CHAPTER Related information Sources of related information include the following e Release notes The release notes describe new features of the product information not included in the manuals and any changes to the manuals The release notes are available at www trimble com e Trimble training courses Consider a training course to help you use your GPS system to its fullest potential For more information go to the Trimble website at www trimble com training html Technical assistance Contact your Trimble Reseller for technical assistance CFX 750 Display User Guide 15 1 Introduction 16 CFX 750 Display User Guide Installing the Display and Antenna In this chapter This chapter introduces the CFX 750 display and system components and also describes how to m System components install the display and antenna Installing the display m Connecting the display m Installing the antenna CFX 750 Display User Guide 17 2 Installing the Display and Antenna System components Item Description Part number Oo CFX 750 display 94110 00 RAM mount and screws 61958 Quick reference card 78838 00 ENG 4 Compact disc 78821 02 GPS antenna cable 50449 O Power bus CAN cable 77282 7 Power cable 67258 01
139. splay to a newer firmware version e Unlock features such as Field IQ crop input control system Upgrading your display Ss SS Transfer the new firmware file from www trimble com to your office computer Connect the CFX 750 display USB memory stick to your office computer Unzip the firmware file and then save it to the root folder of the USB memory stick Insert the USB memory stick into the USB socket of the display In the Unlock Upgrade screen tap Firmware Upgrade Wizard Select the file to upload and then tap gt The firmware begins to load Once the new firmware has successfully loaded the display automatically restarts Do not disconnect the power from the display while it is rebooting Unlocking features Note To unlock features you must obtain an unlock code from your Trimble reseller 1 In the Unlock Upgrade screen tap Password Upgrade 2 Enter the unlock password Passwords are case sensitive Once the password is successfully entered the display automatically restarts Do not disconnect the power from the display while it is rebooting Status Use the Status screen to view the current status of the system The items that appear in the Status screen vary according to the features that you use Select this item Region protect Language Pack status LB25 remote lightbar status 176 CFX 750 Display User Guide To view The GPS signal region you are currently in and whether it is locked or
140. ss the SET button to switch the controller between GPS and non GPS modes Note If you do not set the Rawson controller to use GPS mode the CFX 750 display will only log the rates being used For more information on configuring the Rawson controller refer to the ACCU RATE Controller 9 2A User Guide Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup e Swath Control e Target Rate e Default Rate e Step Size Rate Snapping Boom Setup Use this option to view and adjust the following settings Setting Notes Implement width Enter a width between 1 00 328 01 0 30 99 99 m Number of sections Enter a number between 1 10 Swath Control Use this option to view and adjust the following settings Setting Notes Boom control Enter a width between 1 00 328 01 0 30 99 99 m Coverage switching Control the amount of boom switching overlap allowed before the overlap section will be switched by the system Enter a value between 1 99 Boundary switching Control the amount of overlap on a boundary before the boom overlap section is switched off Enter a value between 1 99 On Off valve latency Tune the section switching to allow for hardware delays Enter a time between 0 0 10 0 seconds Intentional overlap Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area Enter a distance between 0 00 32 10
141. t Old To set up the new field progress through the wizard Follow the on screen instructions to drive your new line For more information see Mapping an AB line page 140 CFX 750 Display User Guide 137 6 Mapping and Guidance Record keeping Optionally you can record operational and environmental information about each field that you create including e Operator e EPA license number e Harvest year e Farm location e Vehicle e Implement e Application method e Wind speed e Wind gust speed e Wind direction e Sky conditions e Soil conditions e Temperature e Humidity e Crop e Target pests e Applied material Additionally there are four custom fields where you can enter your own values To learn how to use this information see Chapter 8 Data Resetting guidance To reset guidance in the guidance view tap IIIN The Finished with Field screen appears Finished with Field Hanne au fined working ah Che current haldi To map a new e field or select an existing field select Yes e AB line or select an existing AB line in the current field select No Note If you select Yes then the current field automatically closes This means that you cannot cancel out of the New Field wizard and go back to your current field Guidance lines To create a guidance line you define a start point A and an end point B Once you define the A and B points the display draws a line between them This is the master AB l
142. tart point of the FreeForm curve 2 Touse Manual recording tap Sh Record with Coverage tap either o or While the display is recording the current path eo appears on the guidance screen 3 Drive the curve To record straight sections you can use the pause feature See Creating straight sections on Headland or Curve swaths page 136 4 To finish recording do one of the following If Auto U Turn Detection is on perform a tight U turn For Manual recording tap So If you are using Record with Coverage tap 5 or ahi Note If Auto U Turn Detection option is off you must manually stop recording at the end of each pass and then start recording again at the beginning of the next pass Using the FreeForm pattern to define a straight AB line 1 Tap and then drive to the end of the line 2 Atthe end of the line tap B Switching to another line To switch from the current FreeForm guidance line to another tap i A The first time you tap the icon guidance snaps to the next nearest curve Continue tapping the icon to cycle through other guidance lines Note To use this feature the vehicle must be within 1 5 swath widths of a FreeForm curve Using FreeForm curves in spiral fields If you are creating a spiral into the center of the field drive the full circuit and then back onto the start of the FreeForm curve Continue to record your guidance path as you Spiral toward the center of the field If you encou
143. teering corrections occur at the correct point e To improve the performance of your swather adjust the Swather steering delay setting by a small amount 0 1 seconds at a time Test the result between each adjustment After using the EZ Steer system e Any time that you are not using the EZ Steer system pivot the EZ Steer motor away from the steering wheel e Before you leave the vehicle turn off the EZ Steer system power switch or remove the power plug The EZ Pilot steering system The EZ Pilot steering system works with the CFX 750 display s internal GPS receiver to provide vehicle guidance You must therefore complete the GPS setup before you calibrate set up or run your EZ Pilot system See Chapter 7 GPS Setup To view and adjust the settings for the EZ Pilot system 1 Inthe guidance screen tap P and then tap Vehicle 2 Tap Auto Steer and then EZ Pllot Setup Auto Steer Note If the EZ Pilot Setup button does not appear tap Auto Steer System Type and then select EZ Pilot for your controller The EZ Pilot Setup screen contains the following options Engage Options 56 CFX 750 Display User Guide Vehicle 4 e Vehicle Setup e Aggressiveness e Vehicle Calibration menu The following sections describe each option Engage Options Use this option to view and adjust the settings described below Setting Notes Minimum Maximum Enter the minimum and maximum speeds at which the EZ Pilot
144. ter switch to ensure that spray is not applied Note The only time the CFX 750 display sends a zero rate is when the sprayer is outside a prescription boundary and the Rate outside polygon option is zero The operator must ensure that the master switch is off when there is no field open so that no spray is accidentally applied to areas that shouldn t be sprayed for example roads paths and neighboring fields Once you select Raven as your controller the following screen appears on the display Output Port Pree CFX 750 Display User Guide 109 5 Implement Application Controller Note Do not configure the display to output NMEA messages on the same port that your controller is connected to 2 On the Raven controller configure the following Data Menu settings Item Setting Baud or Baud Rate 9600 GPS Inac DLOG or Data Log On TRIG or Data Log Trigger Value 1 UNITor Data Log Trigger Units sec Note n the GPS group if Send time Time acknowledge or Close file appear change them to GPS Inac Otherwise the DLOG or DATA LOG option will not appear For more information on configuring and calibrating the Raven controller refer to the Raven instruction manual Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup e Target Rate Rate Snapping Boom Setup Use this option to view and adjust the following settings Setting Notes Imp
145. that uses electric current to control the hydraulic valve output Note These setting also control default setting for Valve Response settings Set the valve plumbing for servo type valves only that is Servo Servo Fast and Hardi Bypass Servo Note Pump Servo does not have a plumbing type as it controls hydraulic flow to the pump This is similar to a PWM setup The options are e Inline The control valve is between the pump and the sections nozzles This means that the control valve controls the amount of material out to the section nozzles directly Note If you need more material out to the section nozzles the control valve has to open more to allow more material to reach the section nozzles e Bypass The control valve is between the pump and the tank This means that the control valve controls the amount of material that goes back to the tank Note If you need more material out to the section nozzles the control valve will have to close more to force more material out to the sections nozzles Implement Application Controller 5 Select Options Description Drive Setup Feedback Setup Shaft Encoder Enter the pulse per revolution for the Feedback Setup Constant feedback sensor you have connected to this module i eS F ery Ser RS Felkin j Senna FrEE oe ae Bri Egr EA l ET LE je Gear Ratio Calculator Use the calculator to calculate the gear ratio if Lal all Gear Ratio
146. that when applying there are no gaps in coverage if you move into an uncovered area or out of a covered area Use this option To set the distance that you want to travel before On overlap distance Exiting a covered area and switching the implement on Off overlap distance Entering a covered area and switching the implement off Target rate Use this option to set the target application rate the amount of product you want to apply Enter a number between 1333 41333 Valve aggressiveness If you use an auto steer system such as an EZ Steer or Autopilot system you can use this option to adjust how the system responds to steering changes Note the following e A higher setting brings the vehicle back on line quickly but may cause tight oscillations e lt A lower setting gives a more moderate response to bringing the vehicle back on line but can avoid overshoot Enter a setting between 50 150 The Field icon From the guidance screen tap HIN to create a new field or select an existing field See Chapter 6 Mapping and Guidance The Guidance icon From the guidance screen tap i to quickly nudge shift or resume a guidance line x Mudge Right 40 CFX 750 Display User Guide Getting Started 3 The Mapping icon From the guidance screen tap 4 to quickly add or delete the following features e rock e line e tree e area e weed Exclusion e exclusion The Auto steer icon
147. the Raven master switch is on and the booms are on CFX 750 Display User Guide 111 5 Implement Application Controller Target Rate To manually enter a rate to send to the controller 1 Inthe Settings screen tap Implement and then Advanced 2 Tap Target Rate and then adjust the rate that is sent to the controller Automatic Boom Switching The CFX 750 display will not do automatic boom switching for the Raven controller Note To ensure that areas outside the headland in exclusion zones or previously sprayed areas are not sprayed you will need to manually turn off the Raven controller master switch Rawson controller Setup 1 Once you select Rawson as your controller a warning message appears Make sure that you read the message carefully and then tap gt to continue Output Port Part A 2 Change the Output Port to COM or AUX to match the port on the display that the controller is connected to 3 On the Rawson controller Verify the default target rate and step size and then enter these values into the CFX 750 display To learn how to change these settings on the CFX 750 display see Advanced below Set the baud rate to 9600 To enable the CFX 750 display to change the rates on the controller you must also set the Rawson controller to GPS mode 1 Turn the Rawson controller on 2 Press the MODE button twice 112 CFX 750 Display User Guide Implement Application Controller 3 Pre
148. the system disengages To adjust the amount of force required to disengage the system change the Override Sensitivity in the Engage Options screen 68 CFX 750 Display User Guide Vehicle 4 Engage status indicators Engage status Ready to engage Engaged Cannot engage Icon color O OO Curve auto steering accuracy in headlands It is possible to engage the EZ Pilot system on headlands with sharp corners at the edge of the field However the EZ Pilot system may be unable to drive around these sharp bends Use one of the following methods to compensate Manually steer the vehicle around the corner and then re engage the EZ Pilot system In the Engage Options screen increase the Disengage Offline distance Vehicle specific performance Before you use the EZ Pilot system consider the following performance suggestions Vehicle type 2WD tractor AWD tractor Sprayer Performance hint With tractors that have SuperSteer for example New Holland TG if the tractor has a SuperSteer front axle for best performance Reduce the Online Aggressiveness value Line up close to the swath and make certain that the front wheels are straight before engaging the EZ Pilot system To get smoother performance when the vehicle is pulling an implement over tilled ground enable the Diff Lock This prevents the machine from pulling sharply to the left or right If you are calibrating on a hard surface turn off Diff Lock T
149. the system to work correctly you must select the correct Rate Column setting If you do not then the applied rate will be incorrect Field IQ crop input control system The Field IQ crop input control system enables the CFX 750 display to control the following e planters e sprayers e liquid strip till toolbars e spinner spreaders Additionally it enables the display to use the Tru Count Air Clutch or Tru Count LiquiBlock valves to perform automatic section control and or use a prescription with Rawson drives to control seed or liquid fertilizer rates The different functions of the Field IQ system that you can configure and control are Application Main functions Planter e Seed section control of up to 48 individual rows Field IQ section control module s needed using the Tru Count Air Clutch e Seed rate control using up to 4 Rawson drives to change seed population Field lQ Rawson Control Module s needed e Seed rate control using up to 4 PWM drives to change seed population e Liquid fertilizer control of up to 48 individual liquid nozzles Field IQ section control module s needed using Tru Count LiquiBlock valves Sprayer e Liquid section control of up to 48 individual rows Field IQ section control module s needed using existing boom shutoff valves or Tru Count LiquiBlock valves e Connects to spraying systems that are configured with servo pump servo PWM bypass dump and master valves 76 CFX 750 Display User
150. time To display and log times in your local time set the time zone offset Location Standard Time Offset CDaayiight Savings Time Offset US Eastern Time 5 00 4 00 US Central 6 00 5 00 US Mountain 7 00 6 00 US Pacific 8 00 7 00 Australia East 10 00 11 00 excludes QLD Australia Central 9 30 10 30 excludes NT Australia West 8 00 8 00 View There are three options for the map views View Description Auto Headland The view automatically swaps between overhead view in headlands and trailing view on swaths Auto Engage The view automatically swaps between overhead view not engaged and trailing view engaged Manual You must manually change between overhead and trailing view CFX 750 Display User Guide 169 9 System Status Popup Transparency Use this option to control the transparency level of the status popup tab At this level of transparency The tab is 10 completely solid 1 barely visible Backlight You can adjust the brightness of the screen backlight to maximize visibility and reduce glare in different light conditions For more information see Color Scheme page 169 Touchscreen speaker volume You can adjust the volume of the speaker according to your preference Choose from Loud Quiet or Off Lightbar Setup You can adjust the lightbar settings as follows Use this setting To Look Ahead Allow time for large vehicles to correct offline error e For lar
151. to the following appears VR Controller Status Merre a Eatum HARD 2500 Cornmactsd 3 Check that the status displays Connected Note If the status displays Not Connected verify that the controller cable is securely connected to the display If the cable is secure verify that the display and the controller are configured correctly as detailed in the sections above CFX 750 Display User Guide 127 5 Implement Application Controller 128 CFX 750 Display User Guide Mapping and Guidance In this chapter Introduction Configuring the Guidance settings Starting Guidance Fields Resetting guidance Guidance lines Guidance Patterns Coverage logging The pause resume function Curve smoothing This chapter describes the type of guidance information that the CFX 750 display provides CFX 750 Display User Guide 129 6 Mapping and Guidance Introduction While you work guidance information appears on the CFX 750 display screen and the integrated lightbar that indicate the e position of your vehicle in the field e guidance lines e offline distance To receive this guidance information and any assistance from an auto steer system you must do the following 1 Configure how the guidance appears on your screen See Configuring the Guidance settings below 2 Seta guidance line See Guidance lines page 138 3 Configure the lightbar See Lightbar Setup page 170 Configuring the Guidan
152. to this location Select the button showing the location that you want to set up first and then select the serial number of the row monitoring module connected to this location Note If you have two row monitoring Modules on this location repeat these steps for the second module You can have no more than two modules per location Enable and disable individual sensors Implement Application Controller 5 Sensor Setup Control Setup Edit Screen l Sensor Setup l Add Sensor l Sensor Type l j Pressure Sensors Air Pressure Liquid Pressure RPM Sensor Bin Status Sensor Gate Height Sensor NH3 Pressure Vacuum Pressure y y Y Y Sensor Name Sensor Name Sensor Name Sensor Name y y y Y Module Assignment Module Assignment Module Assignment Module Assignment Y Y Y y Input Location RPM Calibration Alarm on Change Enable Sensor Y y y Y Enable Sensor Enable Sensor Alarm Text Sensor Summary Y y Sensor Summary Sensor Summary Enable Sensor Y Sensor Summary Once you select a sensor type complete the screens as described below tap gt to move to the next screen Not all options apply to all sensors Select Options
153. tomatically detect that the vehicle has done a U turn and generate the next guidance line Off Manually control when a path is finished With the FreeForm pattern you must manually stop recording With the adaptive curve pattern you must manually set the B point CFX 750 Display User Guide 131 6 Mapping and Guidance Coverage Settings Configure the Coverage Settings options to suit the requirements of your system Coverage on off delay If you activate coverage logging at the same time as you enable your spraying or spreading system set a coverage delay that matches the time it takes for flow to start when you turn on your spraying spreading system This ensures that the display records coverage from the actual start point of application You can enter a delay time between 0 0 10 0 seconds Coverage logging Use this mode To Disabled Turn coverage logging off Manual Turn coverage logging on and off manually Engaged Automatically enable coverage logging when the auto steer system is engaged Switch Use a remote switch to turn coverage logging on or off Nudge Settings Option Description Clear nudge at swath end When enabled the display clears the nudged position each time you change swaths Reset nudge When enabled any applied nudge is cleared and all swaths return to their original positions Nudge increment Each nudge moves the guidance line by this value The default nudge increment 132 is O 1 2 5 cm
154. up Material Setup Edit settings by predaing each one individuality Press he greer accept button Co lt p te 88 CFX 750 Display User Guide Implement Application Controller 5 Setting up a Location 1 Inthe mplement screen tap Control Setup Implement 2 Inthe Control Setup screen tap the location button for the location you want to set up If this is the first time that you are setting up a control setup there will be one button only Unassigned 3 Inthe Unassigned screen tap Edit Control Setup Edit Screen i y y Section Control Row Monitoring Material Setup Material Control Setup Rate Control Setup Setup Sensor Setup see page 90 see page 90 see page 91 see page 94 see page 98 see page 99 4 Inthe Edit screen select each option in turn and complete all options and settings If you tap you are either taken to the next screen in a sequence or returned to the Edit screen where you can select the next option Additional options appear as you complete each one CFX 750 Display User Guide 89 5 Implement Application Controller Material Setup The Material Setup screen allows you to easily switch the materials into a control location The location button shows the name of the location and the material that is currently assigned Select Location Name Material Assignment Material Assignment Material Control
155. ve wheel motor CFX 750 Display User Guide 57 4 Vehicle Aggressiveness Use this option to view and adjust the settings described below Setting Notes Online Control how aggressively the EZ Pilot system corrects deviations from the guidance line aggressiveness Enter a value between 50 150 Approach Control how fast the EZ Pilot system steers the vehicle onto the guidance line aggressiveness Enter a value between 50 150 Vehicle Calibration Menu See Angle Per Turn calibration page 61 Calibration Before you begin to use the display you must calibrate the EZ Pilot system To do this complete the Quick Start Wizard see The Quick Start Wizard page 32 that appears the first time that you use the display Note You must have GPS connected To calibrate the EZ Pilot system at a later time complete the following process 1 Inthe guidance screen tap eo and then tap Vehicle 2 Tap Auto Steer and then EZ Pilot Setup Auto Steer Note If the EZ Pilot Setup button does not appear tap Auto Steer System Type and then select EZ Pilot for your controller 3 Inthe EZ Pilot Setup screen tap EZ Pilot Calibration Wizard The wizard guides you through the following processes Entering your vehicle measurements T3 roll calibration EZ Pilot calibration 58 CFX 750 Display User Guide Vehicle 4 Entering vehicle measurements For optimum guidance you must take accurate vehicle measurement
156. view the status of the modem unlocks select the Wrench icon and then select System Status Upgrade Options CFX 750 Display User Guide 157 8 Data To use VRS corrections you must unlock the File Transfer VRS Internet and WiFi options Upgrade Options Cea EPH ATE Pro E haies Raia Fenm o Depart Cote DCM Perme enon DCM 300 upgrade option Description Cellular Parameter Modification Needed for DCM 300G modem when the customer supplies their own SIM card Ag Vehicle Bus Future functionality File Transfer VRS Internet and WiFi Required for the use of VRS or Connected Farm Sync functions Configuring the display for VRS corrections Note The display must be unlocked for RTK to use the Trimble VRS correction type 1 To access the GPS Setup screens select the Wrench icon and then select GPS GPS Setup GPS Correction Source RTK 2 Select the option for Trimble VRS Modem and then select Continue 3 From the device selection list select the required Trimble modem option Correction Delivery Chea Wiser reed Gor reg AT aT eed pee hee Geen formers BP Gey Device Selection them ee for cherie HTE aT eed eee ee een foe a A 158 CFX 750 Display User Guide Data 8 Configuring VRS settings 1 Connect the modem and turn it on 2 Select the required Trimble modem and then follow the on screen instructions The first step in the VRS setup wizard is Wireless Modem Setup This
157. ween Overlap Skip swaths e Overlap is a intentional overlap between swaths to avoid any skips e Skip is a intentional skip between swaths Note This setting is used with the Implement Width to set the spacing of the swaths in the field The width of the implement s application coverage area This measurement is used for coverage logging e For planters this is calculated using the A Number of Rows and the Row Spacing Implement Width e The swath spacing is calculated by the Implement Width and the Overlap Skip setting Used for implements that are offset to the Left Right Offset left or right from the vehicle center line This is measured from the center of the vehicle to the center of the implement The measurement adjusts the tractor s path so that the implement is centered on the line Used to reference the distance from the vehicle to the implement application point 5 The offset is measured from the fixed axle of the vehicle to the point on the implement T where coverage logging will be mapped The fixed axle varies depending on vehicle type e Rear axle on front steering tractors and self propelled sprayers e Front axle on 4 x 4 articulated tractors e Center of tracks on tracked tractors Distance from the hitch to where the implement pivots on its ground contact point Measured from the tractor s hitch pin to the soil engagement point that the implement rotates about
158. wer up page 28 If the current calibration does not read your selections accurately use the Recalibrate Touchscreen option to adjust the responsiveness of the touchscreen Alternatively do the following 1 Power off the display and then power it on 2 Wait until the status bar at the bottom of the second startup screen is more than half full Oe CFX 750 Display User Guide 177 9 System 3 Press both brightness control buttons at the same time 4 Hold the two buttons down until the display beeps 178 CFX 750 Display User Guide
159. wo things a Accompany the combined library with a copy of the same work based on the Library uncombined with any other library facilities This must be distributed under the terms of the Sections above b Give prominent notice with the combined library of the fact that part of it is a work based on the Library and explaining where to find the accompanying uncombined form of the same work 8 You may not copy modify sublicense link with or distribute the Library except as expressly provided under this License Any attempt otherwise to copy modify sublicense link with or distribute the Library is void and will automatically terminate your rights under this License However parties who have received copies or rights from you under this License will not have their licenses terminated so long as such parties remain in full compliance 9 You are not required to accept this License since you have not signed it However nothing else grants you permission to modify or distribute the Library or its derivative works These actions are prohibited by law if you do CFX 750 Display User Guide 3 not accept this License Therefore by modifying or distributing the Library or any work based on the Library you indicate your acceptance of this License to do so and all its terms and conditions for copying distributing or modifying the Library or works based on it 10 Each time you redistribute the Library or any work based on the Library
160. xample Corn that is currently assigned Material Assignment To change the material tap the location button and then select a new material If you select No Material the location is disabled CFX 750 Display User Guide Operation Item Implement Application Controller 5 Once you have enabled configured and calibrated your Field IQ crop input control system the following items may appear on the guidance screens Description Material Virtual Rate button Virtual Section Auto Manual switch Virtual Master Switch Rate switch position Quick Access icon Coverage status Target rate F A BAAD Mii begn wA hgn pi P Rate ipii nE Teper L Ti th pt 0 0 Vee DD kin ope DO bie DG ee iF WV Li a 1 1 Notes Use this button to switch between materials Opens the second image shown to the right where you can adjust your rates Shows the current mode for the controller The options are Automatic and Manual Shows the Master Switch status The options are On p and Off a F ee Indicates the current position of the rate switch See Quick Access icon page 38 On Off 7 Inactive ja m The target application rate for the current rate switch position This is the amount of product that you want to apply CFX 750 Display User Guide 103 5 Implement Application Controller Item Description Notes Actual rate The actual application rate This is the amount of p
161. y and coverage logging is ignored The LED has the following status indicators Green The unit is powered and is communicating with the CFX 750 display Yellow The unit is initializing communications with the CFX 750 display Red The unit is powered but not communicating with the CFX 750 display CFX 750 Display User Guide 105 5 Implement Application Controller HARDI 5500 controller Note For the HARDI 5500 controller to work correctly with the CFX 750 display you must install firmware version 3 16 or greater on the HARDI controller and connect a JOBCOM control box Setup 1 Once you select the HARDI 5500 as your controller the following screen appears on the display Output Port Part A Note Do not configure the display to output NMEA messages on the same port that your controller is connected to 2 3 On the HARDI 5500 controller go to the Settings menu Change Remote to Enable For more information on setting up the HARDI 5500 controller refer to the HARDI instruction manual Advanced Use the Advanced option in the Implement screen to configure the following Boom Setup Swath Control Rate Control Off When Stopped Rate Snapping Boom Setup Note The boom setup on the CFX 750 display must match the setup on the HARDI controller If the boom setup differs between the display and the HARDI controller a warning message appears on the display 106 CFX 750 Display Use