Home

LED Saturn Circular Installation Manual

image

Contents

1. hours is required to allow the fitting battery to reach full capacity ie prior to a discharge test As the installer it is your responsibility to conduct the initial discharge testing of the installed fitting Refer to AS NZS2293 8 Verify that the battery is connected to the power pack For Nexus LX product connect the data cable to the power pack PCA For Nexus RF product fit the antenna connector to the hole provided in the base and then install the antenna For more details refer to the Data Connections section 9 Plug the mains cable harness from base to the mains connector on the mounting bracket Secure the base tightening the 2 screws Refer figure 1 10 Energise the fitting and check the operation of the fitting to ensure that the installation was successful Once powered up allow a few minutes to give the battery a small charge then press the test button on the side of the base Check the operation and LED indications per the following tables Refer to the Trouble Shooting Guide on the last page if abnormal operation or indication is encountered Thomas amp Betts Australasia Pty Ltd 2014 Rev 1 0 28 October 2014 2 Thomas amp Betts Australasia Pty Ltd 2014 Rev 1 0 28 October 2014 3
2. speed single twisted pair data cable The Nexus LX User amp Technical Guide describes all you need to know to successfully install a Nexus project Ask for it from your supervisor from your employer or from your nearest Thomas amp Betts product supplier The network cabling of the building must be installed as per the procedure detailed in the Nexus LX User amp Technical Guide No mains or mains carrying cables are to be connected to the data terminals or cables NEXUS RF WIRELESS SYSTEM The Nexus RF range of light fittings are designed to communicate via a proprietary RF network however the electrical installation of the fittings is identical to that of a standard non monitored fitting Thomas amp Betts Australasia Pty Ltd 2014 Rev 1 0 28 October 2014 1 STANILITE STANILITE Complete Solutions in Emergency Lighting Complete Solutions in Emergency Lighting INSTALLATION INSTRUCTIONS 1 Remove the unit from the packing box and inspect it for damage or imperfections If any damage is found do not install the unit but replace it carefully into the packing box and notify the Thomas amp Betts Product Support Hotline in Australia on 1300 666 595 Fitting Type LED State on initial powering no fitting faults 2 Ifall looks okay installation can proceed Flashing green 3 The fitting has removable mounting bracket G flash with 2 red blink flash with 3 red blink 4 Loosen 2 screws to remove
3. STANILITE STANILITE Complete Solutions in Emergency Lighting REMOVAL INSTRUCTIONS 1 Before removing the installed fitting de energise and lock off the mains supply circuit Note There may be 2 actives present ensure all power is isolated before proceeding 2 Remove the diffuser shown in figure 1 3 Remove the base by loosening 2 screws and unplug the mains cable harness from the mains connector on the mounting bracket Refer figure 1 4 Disconnect the mains cable from the terminal block 5 Disconnect the battery plug from the battery 6 Unscrew 2 screws and remove the mounting bracket Note When the fitting is reconnected to the supply it will need 24 hours charging time before it will be capable of a full duration discharge TESTING PRECAUTIONS Once the fitting is permanently connected to the mains supply a commissioning discharge test as required in AS NZS2293 2 must be carried out You will need to allow 24 hours for the battery to fully charge prior to conducting this test presently at the time of writing the standard requires that fittings operate in emergency mode for a period not less than 2 hours for their commissioning test and for not less than 90 minutes thereafter it is required that 6 monthly discharge tests be carried out You will need to keep the records for the commissioning test and enter them into the building emergency services logbook or via other recording methods as allowed by AS NZ2293 2 CON
4. STRUCTION SITES Continuously switching of the mains power supply that is connected to emergency light fittings during the construction phase of an installation will cause these fittings to discharge and charge their batteries many times over a short period this can shorten the life of the battery and will also result in shortened emergency lamp life for fluorescent fittings Thomas amp Betts does not recommend such practices and may not honour the warranty on batteries when they are subjected to such harsh operating conditions Emergency light fittings are designed to be discharge tested once every 6 months as per AS NZS2293 2 subjecting the product to repeated discharge or charge cycles is regarded as an abuse of the fittings TROUBLE SHOOTING GUIDE If you have installed and connected the unit as per the instructions listed earlier and it does not function correctly use the following table as a guide to fixing the problem Look up the type of fault in the left column and check the possible causes from the right column 1 LED light source and indicating LED not lit AC supply not connected or turned off and or Test switch damaged LED light source is lit but indicating LED not lit Test switch damaged or Battery not connected or faulty or USA not connected or turned off 3 The 4 emergency LED s do not illuminate when the test Test switch damaged or button is pressed Battery not connected or faulty 4 The 4 emergency LED s work momentarily w
5. g the installation of this product for the safety of yourself and others Thomas amp Betts recommends that you read this document thoroughly before commencing installation The fittings are designed for easy installation They are advanced pieces of electronic equipment which when treated with care and maintained through regular and appropriate servicing will perform reliably for many years to come SAFETY WARNING In Australia and New Zealand only licensed electricians are permitted by law to work with 240 Volt electrical installations Do not attempt to install or connect this product unless you are a licensed electrician Turn off and isolate the electrical supply before connecting this fitting to the building wires Do not touch the terminals of the terminal block when the light fitting is energised The only user serviceable parts are fluorescent or halogen lamp s LED light sources are not user servicable Do not tamper with the fitting or the warranty will be void As the installer it is your responsibility to ensure compliance with all relevant building and safety codes ie AS3000 AS NZS2293 Refer to the applicable standards for data and mains cabling installation procedures and requirements Important Note This product is designed for indoor use only NEXUS LX DATA CABLE SYSTEM The Nexus range of emergency light fitting are designed to be connected together into a special communication network over a Level 4 or higher high
6. hen the test Battery not yet charged allow up to 24 hours button is pressed If the unit still does not work after checking these possible causes contact Thomas amp Betts Service in Australia on 1300 666 595 Monday to Friday 8 30am to 4 30pm AEST and ask for help Our trained service personnel will usually be able to take your call immediately and assist you in resolving your difficulty Thomas amp Betts is committed to providing valuable Through Life Support for its products Thomas amp Betts Australasia Pty Ltd 2014 Rev 1 0 28 October 2014 4 Complete Solutions in Emergency Lighting Doc No 29 00025 Thomas Betts A Member of the ABB Group Thomas amp Betts Australasia Pty Ltd ABN 062 074 810 898 Head Office Unit D3 3 29 Birnie Avenue Lidcombe NSW 2141 Australia Manufacturing 23a Nyrang Street Lidcombe NSW 2141 Australia Phone 1300 666 595 Fax 1300 666 594 Email austsales tnb com Website www tnbaust com LED Saturn Circular Installation Manual Standard Nexus LX Nexus RF This Document Covers What s Inside the box LED Saturn Circular Installation Manual Safety Warning Installation Instructions Removal Instructions Warranty Information Testing Precautions Trouble Shooting Guide lo GREETINGS Congratulations on choosing to use this Thomas amp Betts product covered by our unique Through Life Support system This document is designed to assist you durin
7. the base from the mounting bracket Refer figure 1 Use the bracket as template to mark mounting 2 TEEN VAS AEA INKS REN ASN A TEO OORS hole and cable entry hole position Note For wall mount orientation refer figure 2 Baka Fitting Type Normal Operation Test Switch Pressed Da after few minutes charging Without motion detect LED panel will illuminate to full brightness when 4 non maintained emergency LED will illuminate a Mains Connector sensor SA is energised es Switch With motion detect The operation of the LED Panel in normal mains 4 non maintained emergency LED will illuminate sensor availability is dependent on the settings of the Motion Detect Module Please refer to separate sheet included for details Diffuser Base Re install the diffuser by lifting 1 clip at a time and insert the diffuser DATA CONNECTIONS NEXUS LX amp NEXUS RF PRODUCT RANGE I Nexus LX fitting wa f Connect the data cable to the green connector on the power pack or PCA or to the fixed Figure 2 Wall Mounting Only terminal block marked DATA Figure 1 Test Switch must be facing down When correctly installed no fitting should have more than 2 data cables connected to it 7 l oe l l _ If you have more than 2 data cables at any 1 fitting the installation is incorrect 5 Secure the bracket to the ceiling or wall using appropriate fixings not supplied depending on the type of building construction If this fitting is at the end of a data cable run a termina
8. tor needs to be connected across material used the 2 data lines 6 Route the mains cable through the cable entry hole The cable needs to be mechanically protected with a grommet gland or bush If there is an in and out data cable then the shields should be wound together folded as it passes though the cable entry hole back and taped up 7 Strip 9mm insulation length from mains cable connect and terminate wires to the terminal block Be careful with multi strand Consult the Nexus LX User amp Technical Guide for further detail including product conductors that all the strands are twisted together before insertion into the terminal Any stray strands that inadvertently come commissioning into contact with their neighboring terminal will cause undesirable results when the fitting is powered Refer table below Antenna P Nexus RF fitting Wire Fitting Type Maintained with SA C Fit the antenna connector through the vacant hole on the gear tray and connect the Switched active Wire to SA terminal ne ata as Sonn ages Tp L Collect the MAC address by removing the peel off sticker section and locating it on your Unswitched active Wire to terminal A lt floor plan or spreadsheet Wire to terminal N Note Other end of the antenna has been pre connected to the power pack or PCA l l Ea AS Consult the Nexus RF User amp Technical Guide for further detail including product Wire to terminal E or Cable commissioning Important Note 24