1. STANILITE STANILITE Complete Solutions in Emergency Lighting Using Stanilite light weight cantilever wall mount bracket WQFCLL Refer Figure 5 for installation of cantilever light weight wall mount bracket WQFCLL The cantilever light weight bracket is manufactured from 1 5mm stainless steel and is powder coated low sheen black In Figure 5 A indicates conduit adaptors can be fitted to these faces Installer must ensure proper sealing of any penetration to the base to maintain the IP rating of the unit The necessary hardware screws nuts and washers are supplied with the bracket The Figure 3 shows how the supplied hardware is used when installing the cantilever light weight wall bracket to the nylon base Wall fixings not supplied ay A Weatherproof fixings supplied with brack d 274 466 574 max position 534 min position Figure 5 Showing installation detail of cantilever light weight wall mount bracket CONSTRUCTION SITES Continuously switching on and off the unit s mains supply during the installation process due to building works or for some other reason could cause the unit s to discharge and charge their batteries many times over a short period This may shorten the life of both the battery and the lamp s Thomas amp Betts does not recommend such practices and may not honour any warranty on the life of the batteries or the lamps when subjected to such harsh operating conditions The unit s are des
2. cy Lighting STANILITE Using Stanilite wall mount bracket WQFWM For robust wall mounting use Stanilite wall mounting bracket part number WQFWM Refer Figure 2 for installation of wall mount bracket The bracket is manufactured from 2 0mm stainless steel and is powder coated low sheen black In Figure 2 A indicates conduit adaptors can be fitted to these faces Installer must ensure proper sealing of any penetration to the base to maintain the IP rating of the unit The necessary hardware screws nuts and washers are supplied with the bracket Figure 3 shows how the supplied hardware is used when installing the wall bracket to the nylon base M6 x 16 SS SKT HD screw Mounting Bracket Weatherproof fitting Lh Ce Fa aaa E is oa te j 7 Shae LLI Rubber sealing washer M6 SS flat washer M6 SS hex nut Figure 3 Showing details of supplied hardware to be used with the bracket Wall Mount Cantilever Options Using Stanilite heavy duty cantilever wall mount bracket WQFCLH For robust cantilever wall mounting use Stanilite heavy duty bracket part number WQFCLH Refer following Figure 4 for installation of cantilever heavy duty wall mount bracket The cantilever heavy duty bracket is manufactured from 6 0mm mild steel hot zinc dipped and is powder coated low sheen black Alternate fixing position a T5 i Wall fixings P supplied n j i a i o 7 Weatherproof fixings supplied wi
3. drill to suit for wall mount using Stanilite wall mount bracket part number WQFWM Wall mounting face 24 Figure 1 Glass Filled Nylon Base drill to suit for mounting 3 Install the ceiling bracket inside the base unit using 2 screws 10 x 1 2 mush nib steel supplied with the unit For mains wiring and installation details of the Quickfit please refer to the Quickfit Installation Manual 4 Once the Quickfit is installed into the mounting bracket you can install the enclosure into the base using either the socket cap or pan Philips head stainless steel M 6 x 16 screws and nuts supplied with the unit Wall Mount Options Without using any wall mount bracket Drill holes in the base to suit refer Figure 1 hole position D for wall mount installation without using any bracket Use appropriate screws as required Installer must ensure proper sealing of any penetration to the base to maintain the IP rating of the unit Bracket clearance on clipsal circular junction box A indicates conduit adaptors A can be fitted in these faces Bracket is manufactured from 2 0mm stainless steel and powercoated low sheen black Alternate fixing position wpe ee s s a Weatherproof fixings supplied with bracket 3 102 Wall fixings not supplied 4 holes 8 5 dia 466 Figure 2 Showing installation detail of wall mount bracket Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 5 0 15April2013 2 Complete Solutions in Emergen
4. igned to be regularly discharge tested once every 6 months as per AS NZS2293 2 Deliberate consistent discharge testing is considered an abuse of the fittings In order to prevent damage to the battery or lamp leave the unswitched active circuit turned off at the circuit breaker until the emergency lighting is required on the site TROUBLE SHOOTING GUIDE If you ve installed and connected the unit as per the instructions listed earlier and it doesn t work properly please refer to the Quickfit Installation Manual s Trouble Shooting Guide If the unit still doesn t work after checking these possible causes contact Thomas amp Betts Service in Australia on 1300 666 595 Monday to Friday 8 30am to 4 30pm AEST and ask for help Our trained service personnel will usually be able to take your call immediately and assist you in resolving your difficulty Thomas amp Betts is committed to providing valuable Through Life Support for its products Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 5 0 15April2013 4 Complete Solutions in Emergency Lighting Doc No 29 01069 Thomas 8etts A Member of the ABB Group Thomas amp Betts Australasia ABN 062 074 810 898 Head Office Unit D3 3 29 Birnie Avenue Lidcombe NSW 2141 Australia Manufacturing 23a Nyrang Street Lidcombe NSW 2141 Australia Telephone 61 1300 666 595 Facsimile 61 1300 666 594 Quickfit Weatherproof Exit LED Quickfit Weatherpr
5. oof Housing Installation Manual What s Inside the box a 1 Glass Filled Nylon Base Qty 1 Qty 1 Qty 1 4 Diffuser Qty 2 if unit is double sided Qty 1 2 Acrylic Polycarbonate Diffuser 3 Millennium Quickfit Frame O r lt 5 Back Plate if unit is single sided Qty 1 6 Nut M 6 Hex S Steel 7 Screw 10 x 1 2 Mush Nib Steel 8 Screw M 6 x 16 S Steel Socket Cap 9 Screw M 6 x 16 S Steel Pan Philips Head 10 Warranty Information Qty 4 Qty 2 Qty 4 Qty 4 GREETINGS Congratulations on choosing to use this Thomas amp Betts product covered by our unique Through Life Support system This document is designed to assist you during the installation of this product so for the safety of yourself and others Thomas amp Betts recommends that you read this document thoroughly before commencing installation The Quickfit range of fittings as the name implies are designed to be fitted quickly These are advanced pieces of electronic equipment and when treated with due care and maintained through regular and appropriate servicing will perform without trouble for many years to come SAFETY WARNING In Australia and New Zealand only licensed electricians are permitted by law to work with 240 Volt electrical installations Do not attempt to install or connect this product unless you are a licensed electrican Turn off and isolate the electrical supply before connecting this fitting to the building wires Do no
6. t touch the terminals of the terminal block when the light fitting is energised The only user serviceable parts are the lamp s Do not tamper with the fitting or the warranty will be void As the installer it is your responsibility to ensure compliance with all relevant building and safety codes ie AS3000 AS NZS2293 Refer to the applicable standards for data and mains cabling installation procedures and requirements Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 5 0 15April2013 1 Complete Solutions in Emergency Lighting STANILITE INSTALLATION INSTRUCTIONS 1 Remove the unit from the packing box and inspect it for damage or imperfections If any damage is found do not install the unit but replace it carefully into the packing box and notify the Thomas amp Betts Product Support Hotline in Australia on 1300 666 595 2 Ifall looks okay proceed for installation Take the the nylon base and drill holes to suit refer Figure 1 Base mounting screws are not supplied with the unit Use appropriate screws as required depending on your installation ie wall or ceiling Installer must ensure proper sealing of any penetration to the base to maintain the IP rating of the unit A Drill to suit for ceiling mount B Drill to suit for conduit entry C Drill to suit for standard junction box mounting or top side conduit entry D Drill to suit for wall mounting A Also
7. th bracket 274 4 holes 11 0 dia 466 580 max position 540 min position Figure 4 Showing installation detail of cantilever heavy duty wall mount bracket In the above Figure 4 A indicates conduit adaptors can be fitted to these faces Installer must ensure proper sealing of any penetration to the base to maintain the IP rating of the unit The necessary hardware screws nuts and washers are supplied with the bracket The Figure 3 shows how the supplied hardware is used when installing the cantilever heavy duty wall bracket to the nylon base Copyright 2013 Thomas amp Betts Australasia ABN 062 074 810 898 Rev 5 0 15April2013 3