1.
2. PLANMECA Chair user s and installation manual Table of contents O a BON a 10 11 12 13 14 INTRODUCTION bis scsecs ca cteedcs ia RA Aa a A 1 ASSOCIATED DOCUMENTATION cooocccocccnconnconnconnnennnnnnnnnnnnnnnnnnnnnnnrnnrennrnnnrrnnnrnnarnnnennnrnennnees 1 TRAINING iii A a oi i 1 SYMBOLS ON PRODUCT LABELS cocoocccnccnncnoncnnccnnnonnnnnnnnnnnnnncnnnennnrnnnrnnrrnnnrnnnrnnrennrrnnrrnnnnnns 2 FOR YOUR SARETY sia aaa 3 PEANMECA CHAIR caia AAA As 4 SAPER V F Ln A OTe 1 e PEE A E E ETTE ada Dd iaa decias 4 6 2 cApplied parts occ A A ea a a aaa a i 4 USING CHAIR 0 0 A A A ii etd cee 5 NS O TO 5 F2 E O 6 7 3 Adjusting chair headrest 5 ccccecedeeeeescecceeeeeeeeedeeeneccanceceessenceteegecsedeeeaaeseneeenesueneeeeessaneneesesent e 6 TA Cairn SWIVEL oia ia ata 8 To AUtoMatic legros oaae n e A iaa 9 FS Trendelenburg Position tics aa aaa EE a EAA EREA 10 7 7 Driving chair to required position cccccccccceececeeeeteeeeceneaaeeeeeeeeeeeeeseeeeceaeeeeeeeeeeeeeeeeeenenaeess 10 PROGRAMMING CHAIR POSITIONS c occcocccncccncccnncnnnonnonononanonanoncnoncnnnronnrnnncrnnrnnnrnnnnenrnenans 13 OPTIONAL FEATURES anane a cil as 14 9 T Child CUSNION St eraai n aa E EEE E A N 14 9 2 Operating light post and OP tray sesi AREE eA RE RNEER ONARE RRT A N aA 14 9 3 gt Remote control panel it 15 94 Mobile base sionerien ea aia dalt hia lass 18 MAINTENANCE inicia aras 19 10 11 Cleaning upholStety en
3. that also the fuse nests must be replaced 32 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 4 Changing power source Plug two fuses Fixed power source one fuse When the Planmeca patient chair is delivered from the factory it is equipped with a power supply cable with plug If however the chair is to be attached to a fixed power source the N fuse has to be bypassed CHAIR PCB CAUTION When servicing the unit always first switch the unit off by removing the plug from the wall outlet and then wait for 2 minutes before touching any electrical parts CAUTION Note that the mains voltage is always present at the mains terminal under the main control PCB cover even if the unit is switched off from its own mains switch User s and installation manual Planmeca Chair 33 12 INSTALLING PLANMECA PATIENT CHAIR To bypass the N fuse follow the instructions below 1 Open the cover of the mains junction box The picture below shows the factory default configuration IMG_11324 JPG 2 To bypass the N fuse move the blue wire from connector N fused to N fuse shorted 34 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 3 If needed change the used voltage by changing the voltage selector For instructions see section 12 3 Changing voltage on page 30 4 Remove the power supply cable and attach
4. NOTE The chair can be driven to the automatic positions also using the foot control see section 7 7 2 Automatic operation on page 14 18 Planmeca Chair User s and installation manual 9 OPTIONAL FEATURES 9 3 3 Programming chair positions The chair incorporates a memory in which you can store the chair positions that you want the chair to move to in the automatic mode There are four chair positions available the rinsing position C and three working positions A B D The positions have been preprogrammed at the factory and can be changed by the user as follows NOTE The chair positions can also be programmed using the foot control see section 8 PROGRAMMING CHAIR POSITIONS on page 15 1 Move the chair to the desired position using the foot control or the chair keys on the remote control panel 2 Press the programming key to enter the programming mode When the programming mode is active you will hear a long signal tone every two seconds A B 3 Press and hold the desired chair position key where to store the chair position A B C or D You will hear the same signal tone that you hear when the chair is switched on which indicates that the chair position has been programmed into the memory If you want to exit the programming mode without changing the chair position press the programming key briefly NOTE If you interrupt programming for over 25 seconds the chair automatically exits t
5. for disposal material disposal site separate collection Frame and covers metal Aluminium X Galvanised steel X Stainless steel X plastic PUR X Other plastics X rubber X Motor X PCBs X Cables and Copper X transformers Steel X Packing Wood X Cardboard X Paper X Other parts X 50 Planmeca Chair User s and installation manual 14 TECHNICAL SPECIFICATIONS Construction Weight Backrest angle Swivel Operation Control Ambient temperature Ambient air pressure Relative humidity Altitude Power requirements Electrical classification 14 TECHNICAL SPECIFICATIONS Cast alloy all metal 120 kg 290 Ibs 25 upright from vertical 90 lowest from vertical 90 total 180 Electromechanical 2 motors Microprocessor Operating 15 C to 35 C 59 F to 95 F Storage 5 C to 60 C 23 F to 140 F 800 hPa to 1060 hPa 12 psi to 15 psi 5 RH to 95 RH non condensing humidity lt 2000 m less than 1 25 miles 3A 220 240 VAC 50Hz 60Hz 6A 100 115 VAC 50Hz 60Hz ED 8 25 sec ON 300 sec OFF Class l type B Foot control Class IPx1 220 240 V 115 V 100 V Plug Fuse 2xF4AH250V 2xF8AH 250V 2xF8AH 250V Bussmann S501 4 R Bussmann S501 8 R Bussmann S501 8 R Schurter 0001 1010 Schurter 0001 1013 Schurter 0001 1013 Label LBL 10026426 LBL 10027254 LBL 10027253 Fixed Fuse 1xF4AH250V 1xF8AH250V 1xF8AH 250V Label LBL 10027258 L
6. display The error tones in group 1 are always enabled whereas the error tones in groups 2 5 are disabled To enable the error tones in groups 2 5 for example for troubleshooting purposes contact your Planmeca dealer 11 1 1 Group 1 Error codes with a single beep every two seconds D At least one of the safety switches has been activated The chair and backrest can only be driven in the upwards direction The chair s operation returns to normal automatically after the obstructing items have been removed from under the chair Should this happen without any visible cause most probably the emergency switch of the backrest motor needs to be re adjusted Table 1 Error codes with single beep every two seconds Code Name Description 1 ERROR_SAFETY_LOOP_BROKEN Safety loop is broken 2 ERROR_PROG_STOP_PLATE_PRESSED_WHEN_ Stop program plate was pressed DRIVING when driving 11 1 2 Group 2 Error codes with two beeps every two seconds D If the error tone is continuous over ten seconds the voltage signal received from the lift motor position sensor is below short circuit or above open circuit the programmed limits Either the lift motor position sensor is out of calibration or the sensor and or its cable is broken If the error tone disappears after ten seconds the voltage signal received from the lift motor position sensor is within the programmed limits but it does not change
7. 8 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR ps PM_chair_rem4 e Control panel cable Connect the control panel cable to the connector J18 on the Power supply PCB 10000 mi PFK 4 0 22 mm code 00006769 g k N o N J18 Power Supply PCB Attach the chair to the floor according to the instructions in section 12 2 Attaching chair to floor on page 28 Attach the mains junction plate and the protective strip to their positions User s and installation manual Planmeca Chair 49 13 DISPOSAL OF CHAIR 13 DISPOSAL OF CHAIR In order to reduce the environmental load over the product s entire lifecycle Planmeca products are designed to be as safe as possible to manufacture use and dispose of Parts which can be recycled should always be taken to the appropriate processing centres after hazardous waste has been removed Disposal of obsolete units is the responsibility of the waste possessor All parts and components containing hazardous materials must be disposed of in accordance with waste legislation and instructions issued by the environmental authorities The risks involved and the necessary precautions must be taken into account when handling waste products Table 6 Disposal of parts and components Hazardous Part Main materials Recyclable Waste waste
8. AIR 12 8 Removing swivel mechanism locking screw The swivel mechanism is locked during transportation with a locking screw Note that the chair must be attached to the floor before removing the screw CAUTION If you do not wish to take the swivel feature into use do not remove the swivel mechanism locking screw CAUTION When the chair is equipped with a mobile base see section 9 4 Mobile base on page 20 the swivel mechanism must always be locked Drive the seat to the uppermost position Remove the M8x16 DIN 912 screw from the swivel mechanism Detach the label from the height control cover plate swivel lock eps Detach the label NOTE Keep the removed screw for possible later use for example for unit adapter attachment 46 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 9 Installing wheel assemblies mobile base optional CAUTION When the chair is equipped with a mobile base the swivel mechanism must be locked see section 12 8 Removing swivel mechanism locking screw on page 46 CAUTION Do not install a dental unit or any other equipment to the chair with a mobile base CAUTION Do not transport the chair when a patient is sitting in the chair Remove the protective strips and the plastic plugs 5 5 pcs from the chair base Enlarge the fastening holes 5 5 pcs with a 65 1 mm drill Turn the chair carefully to its side Attach the
9. BL 10027256 LBL 10027255 Maximum lifting capacity excluding the weight of additional equipment IEC 60601 1 Second edition 1988 12 IEC 60601 1 Third edition 2005 12 135 kg 160 kg Maximum allowed weight of additional equipment to be attached to the chair 55 kg Maximum allowed torque caused by additional equipment on chair adapter interface or on Planmeca SingLED OP tray adapter 365 Nm Maximum allowed weight of additional equipment on Planmeca SingLED OP tray adapter 50 kg Original manufacturer PLANMECA Oy Asentajankatu 6 FIN 00880 Helsinki FINLAND Phone 358 20 7795 500 fax 358 20 7795 555 User s and installation manual Planmeca Chair 51 14 TECHNICAL SPECIFICATIONS Dimensions 817 mm 32 1 Max 390 mm 15 4 il fe 1565 mm 61 6 640 mm Backrest 584 25 2 680 mm Backrest 664 26 8 l l l l l l l l 52 Planmeca Chair User s and installation manual 14 TECHNICAL SPECIFICATIONS Backrest angle 65 User s and installation manual Planmeca Chair 53 Planmeca Oy Asentajankatu 6 00880 Helsinki Finland tel 358 20 7795 500 fax 358 20 7795 555 sales planmeca com www planmeca com PLANMEDA Oys PLANMECA Oys Environmental Quality System tom
10. OGRAMMING CHAIR POSITIONS on page 15 NOTE It is possible to disable the automatic movement to the preprogrammed positions by connecting a jumper to the Power supply PCB Contact your Planmeca dealer if needed Press briefly the required chair position key The chair will move automatically to the preprogrammed position A NOTE Position C is the rinsing position Press the C key briefly and the chair will move to the preprogrammed rinsing position The chair remembers its previous working position press the C key briefly again to return back to this previous position To stop the chair from moving before it reaches the preprogrammed position push the foot control in any direction or press any of the chair positioning keys You can also press the backrest the stop plate or the stop bar or press the stop cover on the underside of the lifting Backrest mechanism upwards If you stop the chair by lifting the backrest the stop plate stop bar or stop cover before it reaches its Stop plate preprogrammed position you will hear a signal tone You Stop bar will also hear a signal tone every two seconds when the Stop cover stop switch is active To operate the chair again use the foot control or the control panel keys If you wish to adjust the position of the chair when it has reached its preprogrammed position simply use the foot control or the control panel in manual mode to drive the chair to the desired position
11. PATIENT CHAIR Tighten the attachment screw by turning it counter clockwise figure below 1 Secure the seat upholstery in position with the other six screws as shown in the figure below 2 4 Cover the screw heads marked with number 4 with the cover caps NOTE First tighten the screws manually approx 5 turns Use a tool only after that A i gt gt es oo E D i 1 Sliding bush 4 oS om QD e NOTE The screws must be used to secure the upholstery User s and installation manual Planmeca Chair 37 12 INSTALLING PLANMECA PATIENT CHAIR Cover the attachment screw on the chair underside by placing the installation plate white arrow and the cover plate black arrow as shown in the figure below Attach the cover plate to its position with an attachment screw using a 2 mm Allen key 38 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 5 2 Attaching backrest upholstery Cover the lower velcro on the backrest with for example plastic sheets and adjust the attachment hook so that a 5 mm Allen key fits under it Place the backrest upholstery onto the backrest casting so that the upper edge of the upholstery is approx 1 cm 0 4 in inside from the casting edge Bend the upper part of the backrest upholstery firmly from its sides 1 and slide the backrest upholstery towards you in a way that the attachment hook goes into the groove of t
12. _HIGH Input AC frequency is above maximum level 17 ERROR_INPUT_PHASE_MISSING One of the 24 VAC phases is missing Check connections between transformer and PCB 18 ERROR_UNSUPPORTED_PCB_VER PCB version is either too old or new for current software version Update software or replace PCB 19 ERROR_STICKY_KEY Some user interface button is stuck Check foot controls additional keyboards and internal wirings 11 2 Other signal tones In the following figures a signal tone is shown with a note and the pitch of sound is expressed in Hz Hz 1479 1100 832 5 739 5 660 t ms 100 200 300 400 500 600 The chair is switched on An automatic chair position has been programmed into the memory User s and installation manual Planmeca Chair 25 11 CHAIR SIGNAL TONES Hz 1479 1100 800ms 832 5 739 5 660 100 200 300 400 500 600 700 800 900 1000 t ms 1 A stop microswitch is activated that is the backrest the stop plate stop bar or stop cover is lifted 2 The lift backrest motor position sensor is loose when you are trying to drive the seat backrest 3 The lift backrest motor does not operate as desired The reason can be either a damaged motor or a fault in the PCB 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Ums The chair is in the programming mode 100 200 300 400 500 600 700 800 900 1000 t ms The calibration mode is entered The calibration is de
13. ach mounting point M10x30 DIN 912 10 5 mm DIN 125 M8x60 DIN 571 Sormat LA 10 i 10 5 mm DIN 125 12mm 0 4 in 4 5mm 0 2 in 50 55mm 2 0 in Concrete floor Wooden floor Attach the chair to the floor and replace the foot control cover and the mains junction plate Attach the protective strips to the chair base pes eps Chair_stri User s and installation manual Planmeca Chair 29 12 INSTALLING PLANMECA PATIENT CHAIR 12 3 Changing voltage CAUTION When servicing the unit always switch the unit off CAUTION Note that the mains voltage is always present at the mains terminal under the main control PCB cover even if the unit is switched off from its own mains switch The Planmeca patient chair is suited for three different voltages 220 240 V 115 V and 100 V The voltage selectors are presented below All three selectors are included in the chair delivery 30 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR The used voltage can be changed by simply changing the voltage selector inside the mains junction box IMG_0430_1 jpg After the voltage is changed the label attached to the junction plate as well as the fuses must be changed yr IMG_0418_1 jpg User s and installation manual Planmeca Chair 31 12 INSTALLING PLANMECA PATIENT CHAIR Note that if the cha
14. al treatment situations come in contact with the patient e upholstery e armrests e headrest Operating light post e OP tray 6 Planmeca Chair User s and installation manual 7 USING CHAIR 7 USING CHAIR The chair can be operated manually or automatically When the chair is used manually the foot control must be pushed and held to drive the chair to the position required In automatic use the foot control only needs to be pushed once and the chair will move automatically to the preprogrammed chair position Before the chair can be used in the automatic mode check the preprogrammed automatic positions 7 1 Switching chair on The on off switch is located on the base of the chair below the legrest When the chair is switched on it will give a signal tone The chair is now ready for use The same switch is used to switch the chair off On off switch ps PM_chair_switch e User s and installation manual Planmeca Chair 7 7 USING CHAIR 7 2 Moving armrests The armrests can be moved 90 outwards Before you move the armrest you must lift it slightly to unlock it Both armrests can be locked into the positions presented below Chair_armrests eps 7 3 Adjusting chair headrest 7 3 1 Adjusting height of headrest The height of the headrest can be adjusted by sliding it manually NOTE The headrest can only be pulled out as far as to the MAX mark 8 Planm
15. ar A as 19 10 2 Cleaning chalrbase cie 19 103 Replacing USES isis 20 CHAIR SIGNAL TONES coi dd 21 TLT Error tongs oreina aa aa EE a o a 21 112 Oher signal tones amaaa ead na aa aaa dat 23 INSTALLING PLANMECA PATIENT CHAIR ccceeeeeeeeeee eee eee eeae ee aeesae esa esaeesaeeeaeesaeeeae 25 12 1 Driving chair out from transportation position ce eeteee cee etee eee ee eeceeeeeeetaeeeeeetaeeeeertiaeeeeeees 25 12 22 Attaching chatta Toor iia 26 12 3 Changing Voltage vivida aaa la a EERE 28 12 4 Changing power SQUICO miccional 31 12 5 Attaching UPMOISteny a A A eee aaa 33 120 Attaching headest ii A ee 39 12 7 Alamo aniMreSts eiii a idad iaa 40 12 8 Removing swivel mechanism locking SCTeW ooooocccccnnnnocccccccononnccccnanonncncnnnnnnnnnnnnnnnncncnnnnncnninnnns 44 12 9 Installing wheel assemblies mobile base Optional ooococconnnccccnnonacccocinanancccnonananccccnnnancnnnnnnna 45 12 10 Installing remote control panel Optional oooocoonnocccccnnnnoccccnnanancncncnanoncncnnn nn ncncncnnnncc cc nana nnccnnnnns 46 DISPOSAL OF CHAIR cito a eet eae 48 TECHNICAL SPECIFICATIONS 00 A a idad 49 User s and installation manual Planmeca Chair 1 Table of contents The manufacturer assembler and importer are responsible for the safety reliability and performance of the unit only if installation calibration modification and repairs are carried out by qualified author ized personnel electri
16. cal installations are carried out according to the appropriate requirements such as IEC 60364 equipment is used according to the operating instructions Planmeca pursues a policy of continual product development Although every effort is made to produce up to date product documentation this publication should not be re garded as an infallible guide to current specifications We reserve the right to make changes without prior notice COPYRIGHT PLANMECA Publication number 10027421 Revision 4 Released 26 May 2014 2 Planmeca Chair User s and installation manual 1 INTRODUCTION 1 INTRODUCTION CE Planmeca Chair is a patient chair that can easily be adjusted to various positions thus appropriately supporting the patient during the dental treatment Planmeca Chair is meant to be used by dental care professionals This manual describes how to install and use Planmeca Chair Please read this manual carefully before using the patient chair Planmeca Chair fulfils the requirements of Directive 93 42 EEC NOTE This manual is valid for software revision 2 0 3 or later NOTE The installation of Planmeca Chair is described in section 12 INSTALLING PLANMECA PATIENT CHAIR on page 27 2 ASSOCIATED DOCUMENTATION 3 TRAINING Planmeca Chair comes with the following manuals e User s and installation manual For dental care professionals and service personnel Instructs the service personnel how to install t
17. d installation manual 12 INSTALLING PLANMECA PATIENT CHAIR Attach the pin to the seat with an attachment screw Tighten the attachment screw with 45 Nm force armrest6 jpg Attach the armrest upholstery to the armrest casting with two 2x50 torx screws using TX 25 key armrest1 eps Armrest casting Armrest upholstery User s and installation manual Planmeca Chair 43 12 INSTALLING PLANMECA PATIENT CHAIR Grease the armrest inner surfaces marked with numbers 2 4 with non toxic vaseline 1 before attaching it to the adapter Push the armrest to the adapter at a 45 angle to the seat and then rotate it to the correct direction ps PM_Chair8 e 44 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 7 1 Planmeca Chair left armrest turns to left Remove the white cover plug from the seat casting Place the armrest attachment pin to the opening on the seat in a position shown in the figures below note the direction of the groove Attach the pin to the seat with an attachment screw Tighten the attachment screw firmly Groove Attach the armrest to the attachment pin according to the instructions in section 12 7 Attaching armrests on page 42 When needed the armrest can be turned left to the position shown in the figure below DSC06319 jpg User s and installation manual Planmeca Chair 45 12 INSTALLING PLANMECA PATIENT CH
18. e the seat until it locks to the nearest locking position increment is 5 NOTE Optionally the chair can be locked to its position in the installation phase This disables the swivel movement 10 Planmeca Chair User s and installation manual 7 USING CHAIR 7 5 Automatic legrest The automatic legrest can be moved synchronously to the movements of the backrest that is when you drive the backrest down the automatic legrest is driven up Use the chair movement buttons to drive the patient chair Notice that the lever underneath the legrest has to be unlocked moved to the right in order to move the legrest with the backrest Automatic legrest PM_Chair_legrest_3 eps The automatic legrest can be locked approximately 18 from the horizontal position To lock the legrest the lever has to be locked to the left Support the legrest with your other hand when locking or unlocking the lever Notice that the backrest will move upward and downward when the legrest is locked Horizontal position Approx 18 from the horizontal position PM_chair_legrest_2 eps User s and installation manual Planmeca Chair 11 7 USING CHAIR 7 6 Trendelenburg position If required the patient chair can be inclined from the horizontal position to the Trendelenburg position In the Trendelenburg position the legrest is in the horizontal position and the backrest is driven 4 from the horizontal posit
19. eca Chair User s and installation manual 7 USING CHAIR 7 3 2 Adjusting headrest angle To adjust the angle of the headrest press the bar on the side of the headrest support to release the locking mechanism Manually set the headrest to the angle required and then release the bar When adjusting the headrest should be supported by hand 7 3 3 Adjusting headrest for children or short patients The headrest can be turned around and repositioned for better head support for children or short patients Pull the headrest out Turn it around so that the cushion faces backwards and push the headrest back into the chair Turn the cushion around 180 counterclockwise User s and installation manual Planmeca Chair 9 7 USING CHAIR 7 4 Chair swivel _ f hybrswivel_0199A eps Press the bar on the side of the headrest support to release the locking mechanism and position the headrest at the top of the chair The headrest is now repositioned To adjust the angle of the headrest press the locking bar Manually set the headrest into the required position and then release the bar When adjusting support the headrest with your other hand If required the chair can be swivelled 90 to the right or left Release the locking mechanism by pressing the foot switch located on the chair base The chair can now be manually swivelled up to 90 in either direction Release the knob and rotat
20. he patient chair Describes the chair its different parts as well as explains to the user how the operate and clean the patient chair e Technical manual publication number For service personnel Gives instructions for service situations For a full list of accessories refer to the Planmeca product price list A hands on user s training is given in connection with the installation of Planmeca Chair User s and installation manual Planmeca Chair 3 4 SYMBOLS ON PRODUCT LABELS 4 SYMBOLS ON PRODUCT LABELS AN Type B equipment Standard IEC 60878 Alternating current Standard IEC 60878 Attention consult accompanying documents Standard ISO 7010 General warning Standard ISO 7010 Separate collection for electrical and electronic equipment according to Directive 2002 96 EC WEEE Date of manufacture Standard IEC 60878 Protective earth Standard IEC 60878 OEXPpPO 4 Planmeca Chair User s and installation manual 5 FOR YOUR SAFETY 5 FOR YOUR SAFETY Backrest Stop plate Stop bar Stop cover When driving the chair from one position to another care should be taken In case of emergency the chair will stop when the backrest the stop plate underneath the seat or the stop bar or stop cover on the underside of the lifting mechanism is pressed upwards The chair will also stop when the safety switch on the underside of the legrest is activated The chair can be driven n
21. he programming mode without storing the new position User s and installation manual Planmeca Chair 19 9 OPTIONAL FEATURES 9 4 Mobile base CAUTION When the mobile base is installed to a chair equipped with swivel the swivel must be locked CAUTION The chair must be transported on even surfaces only The chair is not suited for transport over obstructions or on sloping surfaces Gr CAUTION Do not transport the chair when a patient is sitting in it CAUTION Do not sit on the backrest The chair is raised and lowered by turning the levers in the wheel assemblies Planmeca Chair can be moved when the chair is up When the chair is down it is not movable Wheelie Bar assy_0399A eps SS f 2 DI gt Wheel assembly SS Attaching the mobile base is described in section 12 9 Installing wheel assemblies mobile base optional on page 47 20 Planmeca Chair User s and installation manual 10 MAINTENANCE 10 MAINTENANCE 10 1 Cleaning upholstery 10 1 1 Disinfecting 10 2 Cleaning chair base 10 2 1 Disinfecting A mild soap and warm water solution can be used to wipe off stains and spills Let the upholstery air dry The Ultra Relax upholstery stands up to routine disinfections with ethyl alcohol For disinfecting the upholstery between each patient we recommend D rr FD 333 or a similar product After the working day we recommend that you disinfect the upholstery with D
22. he upholstery s backplate 2 User s and installation manual Planmeca Chair 39 12 INSTALLING PLANMECA PATIENT CHAIR Remove the plastic sheets and press the upholstery to its position Press first the centre of the upholstery and then all the edges to attach all the velcros to their counterparts Note that the upholstery should come over the casting 40 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 6 Attaching headrest Transportation plate Remove the transportation plate from the backrest opening Backrest Mountheadr eps Headrest arm 2 Slide the headrest arm inside the backrest Then place the headrest upholstery on the headrest casting Secure it into position by tightening the screw on the back of the headrest casting User s and installation manual Planmeca Chair 41 12 INSTALLING PLANMECA PATIENT CHAIR 12 7 Attaching armrests If you are installing the left armrest that turns to the left see the instructions given in section 12 7 1 Planmeca Chair left armrest turns to left on page 45 Remove the white cover plugs from the seat casting armrest2 jpg Place the armrest attachment pin to the opening on the seat in a position shown in the figures below note the direction of the groove Armrest attachment pin Groove armrest3 jpg armrest5 jpg 42 Planmeca Chair User s an
23. ion To drive the patient chair to the Trendelenburg position first drive the chair to the horizontal position by pushing and holding the foot control to the left After the backrest movement has stopped release the foot control and then push the foot control again to the left Horizontal position PM_chair_legrest_5 eps 7 7 Driving chair to required position 7 7 1 Manual operation NOTE If the Planmeca Compact i Touch v2 dental unit without a chair is connected to Planmeca chair all chair movements are disabled when driving an instrument from the dental unit To adjust the position of the chair push and hold the foot control in the direction indicated on the foot control to drive the chair in the direction required When the chair reaches the desired position release the foot control The foot control will only operate one movement at a time 12 Planmeca Chair User s and installation manual 7 USING CHAIR NOTE The chair movement stops immediately when you release the foot control If the stop is delayed contact your Planmeca dealer Push the foot control towards the chair to drive the seat up PM_Chair3 eps O a 2 O O O IO GW O Push the foot control away from the chair to drive the seat down PM_Chair3 eps Ol O EL Push the foot control to the left to drive the backrest down PM_Chair3 eps OIIO GX Push the foot control to the right to dr
24. ir is attached to a fixed power source only one fuse is used Norway is an exception two fuses are used also with fixed power source Changing power source from plug to fixed is described in section 12 4 Changing power source on page 33 CAUTION Make sure that you select the correct label See fig ure on next page Check the correct fuse values from the technical specifications 14 TECHNICAL SPECIFICATIONS on page 51 and from the label you attached Voltage 100V plug Voltage 100V fixed power source F2 LBL 10027253B LBL 10027255B ESAH 250V 100V 50 60Hz 1000W 100V 50 60Hz 1000W F1 Intermittent operation ED8 Intermittent operation ED8 25 sec ON 300 sec OFF 25 sec ON 300 sec OFF F8AH 250V Voltage 115V plug Voltage 115V fixed power source F2 LBL 10027254B LBL 10027256B FSAH 250V 115V 50 60Hz 1000W 115V 50 60Hz 1000W F1 Intermittent operation ED8 F1 Intermittent operation ED8 25 sec ON 300 sec OFF 25 sec ON 300 sec OFF F8AH 250V F8AH 250V Voltage 220 240V plug Voltage 220 240V fixed power source LBL 10026426B LBL 10027258B 220 240V 50 60Hz 220 240V 50 60Hz F4AH 250V 4 000W 1000W F1 Intermittent operation ED8 F1 Intermittent operation ED8 25 sec ON 300 sec OFF 25 sec ON 300 sec OFF F4AH 250V F4AH 250V Change the correct fuse s according to the instructions given in section 10 3 Replacing fuses on page 22 Note
25. ir positions are saved to the chair a signal is heard 1 With the foot control set the height of the chair and the inclination of the backrest to the positions you require 2 Lift the stop plate briefly twice to enter the programming mode When the programming mode is active you will hear a long signal tone every two seconds 3 Push and hold the foot control in the direction of the position A B C or D where you wish to store the chair position You will hear the same signal tone that you hear when the chair is switched on which indicates that the chair position has been programmed into the memory If you want to exit the programming mode without changing the chair position lift the stop plate briefly NOTE If you interrupt programming for over 25 seconds the chair automatically exits the programming mode without storing the new position User s and installation manual Planmeca Chair 15 9 OPTIONAL FEATURES 9 OPTIONAL FEATURES 9 1 Child cushion set lapsityyny_0299A eps Position the child cushion set onto the chair as shown in the figure Support the backrest cushion with your hand and guide the patient onto the chair NOTE Lift the backrest cushion upwards if it descends when the backrest is in vertical position 9 2 Operating light post and OP tray The Planmeca SingLED operating light or an OP tray can optionally be attached to Planmeca Chair Their installation requi
26. ive the backrest up AV O OO GW Ol O GY CAD O X O User s and installation manual Planmeca Chair 13 7 USING CHAIR 7 7 2 Automatic operation Stop plate Stop bar Stop cover Chairl eps C PM_Chair3 eps The chair incorporates a memory in which you can store the chair positions that you want the chair to move to in the automatic mode There are four chair positions available the rinsing position C and three working positions A B D The positions have been preprogrammed at the factory and can be changed by the user See section 8 PROGRAMMING CHAIR POSITIONS on page 15 NOTE It is possible to disable the automatic movement to the preprogrammed positions by connecting a jumper to the Power supply PCB Contact your Planmeca dealer if needed Push the foot control briefly to the position A B C or D where the preprogrammed chair position is stored The chair will move automatically to the preprogrammed position NOTE Position C is the rinsing position Push the foot control briefly to position C and the chair will move to the preprogrammed rinsing position The chair remembers its previous working position push the foot control again briefly to position C to return back to this previous position To stop the chair from moving before it reaches the preprogrammed position push the foot control in any direction or press the backrest the stop plate or the stop bar
27. m the chair seat NOTE Check that the floor is straight enough maximum clearance between the chair base and floor is 1 5 mm 0 06 in NOTE If the power supply cable plug is used as a means of isolation ensure that the power supply cable plug is readily accessible when needed Do not position the chair so that it is difficult to access the plug There are four fastening screw holes on the chair base Fasten the chair to the floor with four screws Use the chair base as a template and mark the positions of the fastening screw holes to the floor Fastening screws asennuskuva eps Fastening screws If the floor is made of concrete use the M10x30 DIN 912 screws and expansion anchors Drill four 212mm 0 47 in holes 40 mm 1 57 in in depth and place the expansion anchors into them Make sure that the end of the anchor is under the floor surface but not more than 2 mm 0 08 in If the floor is made of wood use the 8x60 DIN 571 lag screws Drill four 5mm 0 2 in holes 50 55 mm 2 0 2 2 in in depth Do not use expansion anchors with wooden floors See figure below 28 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR NOTE Tighten the screws carefully 40Nm Check that the base is firmly against the floor and the chair does not move when trying to tilt it NOTE The mounting hardware must withstand a 200 kg 2000 N 445 Ibf withdrawal force at e
28. n sensor is missing 7 ERROR_BACKREST_POT_OUT_OF_CAL Backrest position sensor is out of calibration 8 ERROR_BACKREST_DOES_NOT_MOVE Backrest motor does not move or it moves to wrong direction 11 1 4 Group 4 Error codes with four beeps every two seconds The lift or backrest motor runs without a command from the foot control or control panel The processor PCB is broken DY DY DY DY dy dy dD dD dy 2s Table 4 Error codes with four beeps every two seconds Code Name Description 9 ERROR_LIFT_MOVES_WITHOUT_CMD Lift motor moves without command 10 ERROR_BACKREST_MOVES _ Backrest motor runs without command WITHOUT_CMD 24 Planmeca Chair User s and installation manual 11 CHAIR SIGNAL TONES 11 1 5 Group 5 Error codes with five beeps every two seconds MD D D DY Dy My MY My Dy 2s Hardware problem See table 5 Table 5 Error codes with five beeps every two seconds Code Name Description 11 ERROR_FLASH_ERROR Auto position read or write failed Try power off on or replace PCB 12 ERROR_INPUT_VOLTAGE_MEAS_ERROR _ Input AC voltage not detected PCB is powered from DC voltage or it is broken Fix mains input or replace PCB 13 ERROR_INPUT_VOLTAGE_LOW Input AC voltage is below minimum level 14 ERROR_INPUT_VOLTAGE_HIGH Input AC voltage is above maximum level 15 ERROR_INPUT_FREQUENCY_LOW Input AC frequency is below minimum level 16 ERROR_INPUT_FREQUENCY
29. or press the stop cover on the underside of the lifting mechanism upwards If you stop the chair by lifting the backrest the stop plate stop bar or stop cover before it reaches its preprogrammed position you will hear a signal tone You will also hear a signal tone every two seconds when the stop switch is active To operate the chair again use the foot control If you wish to adjust the position of the chair when it has reached its preprogrammed position simply use the foot control in manual mode to drive the chair to the desired position 14 Planmeca Chair User s and installation manual 8 PROGRAMMING CHAIR POSITIONS 8 PROGRAMMING CHAIR POSITIONS Stop plate GZD E PM_Chalr3 eps The chair incorporates a memory in which you can store the chair positions that you want the chair to move to in the automatic mode There are four chair positions available the rinsing position C and three working positions A B D The positions have been preprogrammed at the factory and can be changed by the user as follows NOTE In case your chair is equipped with an optional remote control panel you can also program the chair positions using the control panel keys see section 9 3 3 Programming chair positions on page 19 NOTE If the Planmeca Compact i Touch v2 dental unit without a chair is connected to Planmeca chair the chair positions can also be programmed from the dental unit When the cha
30. or changes in the wrong direction when the motor is run Either the lift motor position sensor is not in contact with the motor s worm screw or the processor PCB is broken User s and installation manual Planmeca Chair 23 11 CHAIR SIGNAL TONES Table 2 Error codes with two beeps every two seconds Code Name Description 3 ERROR_LIFT_POT_MISSING Lift position sensor is missing 4 ERROR_LIFT_POT_OUT_OF_CAL Lift position sensor is out of calibration 5 ERROR_LIFT_DOES_NOT_MOVE Lift motor does not move or it moves to wrong direction 11 1 3 Group 3 Error codes with three beeps every two seconds If the error tone is continuous over ten seconds the e e al voltage signal received from the backrest motor position sensor is below short circuit or above open circuit the programmed limits Either the backrest motor position sensor is out of calibration or the sensor and or its cable is broken If the error tone disappears after ten seconds the voltage signal received from the backrest motor position sensor is within the programmed limits but it does not change or changes in the wrong direction when the motor is run Either the backrest motor position sensor is not in contact with the motor s worm screw or the processor PCB is broken Table 3 Error codes with three beeps every two seconds Code Name Description 6 ERROR_BACKREST_POT_MISSING Backrest positio
31. ormally after the possible obstruction has been removed NOTE Because of the chair swivel feature the stop plate located on the underside of the seat does not cover the whole surface CAUTION Electromagnetic interference between the equipment and other devices can occur in very extreme condi tions Do not use the equipment in close conjunction with sensitive devices or devices creating high elec tromagnetic disturbances CAUTION Switch off the unit before using an electrosurgical Knife CAUTION Do not use the equipment in close conjunction with anaesthetic gas or in highly oxygenated environ ments oxygen content gt 25 WARNING No modification of this patient chair is allowed WARNING To avoid risk of electric shock Planmeca Chair must only be connected to a supply mains with protective earth Canada only External fuse max 20A branch circuit fuse WARNING Do not perform maintenance procedures or replace patient chair parts while treating a patient User s and installation manual Planmeca Chair 5 6 PLANMECA CHAIR 6 PLANMECA CHAIR 6 1 Main parts Headrest Backrest Lifting mechanism Foot control Swivel foot switch Base On off switch CAUTION Do not sit on the legrest NOTE The optional features of the chair are described in section 9 OPTIONAL FEATURES on page 16 6 2 Applied parts The following parts of Planmeca Chair will in norm
32. res that an adapter be installed between the patient chair and the operating light post 1 Operating light post 2 OP tray 3 Adapter CAUTION When driving down the chair make sure that nothing gets squeezed between the adapter and the floor 16 Planmeca Chair User s and installation manual 9 OPTIONAL FEATURES 9 3 Remote control panel C Programming key Chair positioning Px i Press and hold the A key to drive the backrest down When it reaches the desired position release the key Press and hold the B key to drive the backrest up When it reaches the desired position release the key Press and hold the C key to drive the chair up When it reaches the desired position release the key Press and hold the D key to drive the chair down When it reaches the desired position release the key NOTE The chair can also be driven using the foot control see section 7 7 1 Manual operation on page 12 User s and installation manual Planmeca Chair 17 9 OPTIONAL FEATURES 9 3 2 Automatic operation The chair incorporates a memory in which you can store the chair positions that you want the chair to move to in the automatic mode There are four chair positions available the rinsing position C and three working positions A B D The positions have been preprogrammed at the factory and can be changed by the user See section 9 3 3 Programming chair positions on page 19 or 8 PR
33. rr FD 372 or a similar product Once a week we recommend that you clean and treat the upholstery with D rr FD 360 Wipe away any excess oil after the treatment The chair base can be cleaned with a soft cloth moistened with a mild cleaning solution Do not use abrasive cleaning agents For disinfecting we recommend D rr FD 312 or a similar disinfecting solution User s and installation manual Planmeca Chair 21 10 MAINTENANCE 10 3 Replacing fuses CAUTION When servicing the unit always first switch the unit off by removing the plug from the wall outlet and then wait for 2 minutes before touching any electrical parts CAUTION Note that the mains voltage is always present at the mains terminal under the main control PCB cover even if the unit is switched off from its own mains switch The fuses are located on the base of the chair below the on off switch Turn the fuse holder counterclockwise to remove it from the chair Replace the old fuse with a new one of the same type and rating Put back the fuse holder and switch the chair on IMG_11293 JPG 22 Planmeca Chair User s and installation manual 11 CHAIR SIGNAL TONES 11 CHAIR SIGNAL TONES 11 1 Error tones The different modes of the chair as well as some of the erroneous situations are expressed with signal tones If the Planmeca Compact i control panel is connected and service mode is entered the unique error code can be read from the
34. scribed in the Planmeca Chair technical manual In the calibration mode of the chair both the lift and backrest motors can be driven regardless of the voltage signal from their position sensors Therefore this mode is convenient for testing whether the cause for a non operational motor is the motor itself the processor PCB or the position sensor and or its cable If the motor can be run in the calibration mode the fault site refers to the sensor and or its cable WARNING In the calibration mode the motors can be driven to their mechanical limits 26 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA PATIENT CHAIR 12 INSTALLING PLANMECA PATIENT CHAIR 12 1 Driving chair out from transportation position Plug the chair to a mains outlet and switch it on see section 7 1 Switching chair on on page 7 Drive the seat upwards and remove the transportation support piece from the stop bar Stop bar Transportation support piece N pakkauspala eps Stop bar Lifting mechanism User s and installation manual Planmeca Chair 27 12 INSTALLING PLANMECA PATIENT CHAIR 12 2 Attaching chair to floor CAUTION The chair must be bolted to the floor before attaching the upholsteries and before installing any equipment to the chair The chair must be bolted to the floor even if the loca tion is temporary e g in trade shows Do not remove the caution label fro
35. the correct label to the mains junction plate The different labels are shown in section 12 3 Changing voltage on page 30 5 Close the cover of the mains junction box 12 5 Attaching upholstery The chair upholsteries are to be attached into their positions over the chair castings Remove the seat backrest headrest and armrests upholsteries from the packing The upholsteries are equipped with velcro tapes that will attach them to the chair castings In addition to the tapes some screws are used to secure the upholsteries into position User s and installation manual Planmeca Chair 35 12 INSTALLING PLANMECA PATIENT CHAIR 12 5 1 Attaching seat upholstery Slide the attachment plates to their positions at the seat upholstery backplate as shown in the figure below a M r Upholst_05_1 eps D Attachment plates N T lt o Ba 1 Attachment screw f E Slide the seat upholstery towards the backrest casting in a way that the attachment screw goes into the groove of the upholstery s backplate You can bend the seat upholstery carefully from its sides to make the attachment easier If the attachment screw does not go into the groove the screw can be slightly opened by turning it clockwise Make sure that you have slid the upholstery as far as it goes 36 Planmeca Chair User s and installation manual 12 INSTALLING PLANMECA
36. wheel assemblies with the M5 x 8 DIN 7984 screws 5 5 pcs according to the figure below Protective strip Plastic plugs y eps PM_chair_wheelie bar ass User s and installation manual Planmeca Chair 47 12 INSTALLING PLANMECA PATIENT CHAIR 12 10 Installing remote control panel optional NOTE Make sure that the software revision of the chairis 1 03 or later Change the software if needed NOTE If the chair is attached to the floor it must be detached before the remote control panel cable is routed to the Power supply PCB The control panel adapter can be attached either above or below the surface see figure below In case the surface is made of wood attach the adapter to its position with the three EJOT DG 4x25 screws supplied with the control panel For other surface types use screws that are suitable for the used surface Route the control panel cable through the adapter Push the control panel into the adapter and secure it to the adapter with the M3x3 DIN 914 fastening screw Remote control panel a ps PM_Chair_rem2 ej Control panel cable i Control panel cable Remove the mains junction plate see figure in section 12 2 Attaching chair to floor on page 28 Route the control panel cable through the opening in the mains junction plate Attach the connector to the control panel cable according to the figure below blue gt 1 yellow gt 2 red gt 3 4