        Installation manual KIMA ZONE 50
         Contents
1. Installation manual  KIMA ZONE 50 a ae ee    Version 3    LCD Display    Red  increase       temperature   Programming   button   Blue  decrease  On Off  temperature  switch    ZONE 50 is an electronic thermostat for electric underfloor heating system with external floor  sensor   ZONE 50 can be installed in standard wall box or flush mounted on the wall with an external  frame box   ZONE 50 controls and regulate the floor temperature to achieve the best room comfort   ZONE 50 is using the adaptive PWM  and PI technics to to give the best performance and to  extend ZONE 50s lifetime   ZONE 50 should not be used to eliminate over temperatures in the floor construction   The only way to eliminate overtemperatures is to design the floor construction with the right  W m  and compensate for the floor constructions thermal insulation and the Wattage per  linear meter Warm Floor Heating Cable or Wattage per square meter Warm Floor Mat   If the buildings insulation properties is poor it can be compensated with another external  heat source  If ventilation heat pump air condition are chosen as the external heat source  it is important that the temperature setting for this heat sources will not be lower than the  floor temperature  this will save energy   The under floor heating construction should never be exposed to high temperatures to elimi   nate the risk of fire  The worst situation will be when the construction have a high power  output per sqm floor and the floor construction i
2. T0104010 Rev 111121    Technical specifications ZONE 50  Voltage    230 VAC    15  50 60 Hz    Users manual  ZONE 50 with a floor sensor are the best and an easy way to control and regulate the    Max output resistance load 3600 W underfloor heating system and to achieve the best comfort  Underfloor Heating system are  Max current 16 Amp always slow reacting system and that depends on the thickness of the floor construction   Relay Normally open Thicker cement based floor constructions gives also a possibility to accumulate heat   Energy consumption  lt 1W If the building have poor insulation value and the heat losses are considerable is it pos   Switch 2 pole  16 Amp sible to lower the energy consumption by using the Economy function with an external  Control range 0 50   C switch or external timer  see technical specifications     Preset temp floor sensor  Economy function  fixed value   Economy function  control signal  Frost protection  fixed limittemp   Frost protection  control signal  Housing   Classification   Category overvoltage    Min Max surrounding temp  turned on    Min Max storage temp   Limit surrounding airpollution  Length sensor cable   Max extension sensor cable  Floor sensor resistance  Dimensions    25   C   5 0 in the display    5  C  LCD display minus 5  C    230 VAC   10  C   230 VDC  rectified  serial connected diode   IP21   Class II   III  Pulse voltage 4kV acc to IEC 60664 1   0  40   C    20  50   C   Class 2    normal aircirculation domestic hom
3. atures    If their will be no heat  see fault finding list                    BR949A15a  BRO49A 16a       es      ce   p       mi                                                             Fig  1 Fig  2   Documentation   Installations manual  Users manuals and any other documents for the floor construction  should be filed near by the switchboard together with Warranty documents that can prove  that it has been an authorized installer that are responsible for the installation     Environmental disposal   ZONE 50 is an electronic product and should therefor be returned to any envi   ronmental approved depo stations    Products marked with this symbol can   t be disposed together with the normal  household waste  It should be delivered to a waste collection centre in  accordance with the local regulations     Faultfinding ZONE 50  Fault tracing should be done by KIMA authorized fault finder     The floor will not be warm   A  Check that the cables have been connected in the right way and the terminal screws  are tight    B  Check the voltage on terminal 1 and 2    C  Check that the switch on ZONE 50 is switched on  Check the voltage on terminal 3 and  4 when the Heating Cable Heating Mat is on and the LED light is lit as said in  paragraph 5  Measure the electric current with a clamp meter and compare it with the  technical specifications for the Heating Cable Heating Mat   D  Disconnect the Heating Cable Heating Mat and check the total resistance and the  insulation propertie
4. e   3 0 m   50 m  with min 1 5 mm  conductor   se separate table below   H 82  W 82  d 38 mm    ZONE 50 can only operate with a resistive load  such as a heating cable or a heating  mat   an external contactor should be used if the load is larger than 3600 W or a 3 phase    construction     Sensor resistance at diffrent temperatures                               ZONE 50 factory set value are 5 0 LCD display   25 0  C floor temperature    ZONE 50 LCD display controls between 0 10  To change setting press blue or red button  and the LCD display will change 0 1 up or down  It is possible to change the LCD display  to degree C operating mode  see Programming    With ZONE 50 their is also the possibility to change the temperature reading in the  LCD display  Offset  compared with the actual floor temperature to match measured room  temperature  maximum offset 8  C up or down  This will only work when ZONE 50 is opera   ting in the degree C mode    ZONE 50 is maintenance free     Programming   To program parameter values  press and hold the programming button for 3 seconds    In the LCD diplay Lcd    nU will be displayed   At first Lcd for 1 second  then nU ready  to be changed  To continue with the programming with the next parameter press the  programming button  If no button is being pressed within 30 seconds it will return to it   s  operating mode                                      Temperature   Sensor ohm Pos  Parameter   Mode eee Factory setting   Possible to select   call
5. e a j LED display 0 10 Leda a Hone   0  C 38000 or degree C peice j ee   10  C 23300 2 Offset oFF    0     8    20  C 14800   30  C 9700   Warranty   Name property VY escent Stns tc cepted toes tose d inches ceeecea lps aceetcta ad tecestoeneth gland eee eet nintendo Installation Company name  aiccccccacccscssees lt innscscsctosccecntnccobetebesvbens  devtensssensesiassededsndsasnsdestaondousadsla deabseectawnisietnnniehecdtie  Tnstallatiom Adresi epsona atcha ac aac i r S a EEE Installation Company adresinin ae niis  EA EE E AE E E E ceed ene ee eet Installer Company tph no  sec ssscescccsee i ctucscaceccccceatutendetencedeccinedteaateaehsiaicandideloaissapueldbiaay dusvpiadieiiawisbeenlba ied  Installed in type of room  Se ee eee ae eae eee ae ee Semen ene Ce eee a one Purchasing place Company Mamie sa  ccccccccsivecssstevecconssatcszescussolantaleccecvescacecvaciniainaracatilacoinisssaadnndausicnessodanseecaononbsen  Installed date ae omaniecnmiaen vasa ascueagenutansaes angen E EO Purchasing date  atrccs cee tosecee sessed neato uesn my edemdniaeamnudenucuaaainE  Installed WS a tccthseceh cesta ll ca cheered crnecvslncech i r E oN Watt Installed floor SMA SS icin tNaerceis sakeethcdeices onthe uerianniiah anes trciubaawacede  sqm  Installed Wattage per sqm floor         ceeeccccccsssssssssssssssssssssssssssssssssssssssssssssssissiiinnueenees Watt sqm Where Documents are filed          ccccccccssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssnsssssssssssss
6. m from the wall  It is important that the sensor will not be placed in an area were the  heat can be thermally blocked with fixed or movable furniture  wardrobes  kitchen cupboards   etc    If needed the floor sensor cable can be extended with a separate ordinary 1 5 mm  instal   lation cable  maximum length see technical specifications   The floor sensor should not be  installed in the same electrical conduit pipe as the heatingcables heatingmats cold tail or  any other electrical cables  If the floor sensor is connected to a cable with metallic sheath   Don   t earth the metallic sheath     Economy function  Day or Night setback   Lowering the floor temperature with a preset value  see Technical specifications  with an ex   ternal signal  This function doesn   t need to be used if not needed  The external timer should  be installed on a suitable place for example at the switchboard or a manual switch that could  be installed next to ZONE 50  The timer or switch can control more than one thermostat at  the same time  Important to use the right control signal  see technical specifications    LED light will be green when the economy signal is active and red when the heatingcable   heatingmat is energized   see Fig  1     Frost protection   Frost protection will maintain the floor room temperature at a low temperature  see techni   cal specifications  This function doesn   t need to be used if not needed  The external timer  should be installed on a suitable place for example a
7. s and compare them with the recorded values from the installation  that should be filed near the switchboard and compare it with the technical  specifications    E  If the measured electrical values are correct according to the technical specifications  and the construction doesn   t get warm enough the problem could be that the heat  losses are greater than the input power and the reasons could be cold spots   PS  Do  not increase the power out put  that will instead increase the risk of fire and also  shorten the ageing properties of the Heating Cable Heating Mat  Analyze the total  building constructions insulation properties and try to find any cold spot that can  cause the problem  If the floor construction is a concrete slab on the ground check  the moisture  that could be a great problem due to better heat conductivity  Another  problem could be that their is a could area under the floor construction and that   s why  it important to insulate the construction well    F  Disconnect the floor sensor on terminal 5 6 and there will be an error code in the LCD  display    E1     the LED light will flash red once  The same will happened if terminal 5 6  are shortened    G  Check the floor sensors resistance and compare it with the technical specifications   The reading should only change with the temperature    H  If ZONE 50 are turned on and the surrounding temperature are lower than  20  C   ZONE 50 will turn the relay off and when the temperature increase over  20  C it  
8. s thin with a good thermal insulation and  the floor surface will be covered with a carpet or any other good thermal insulating material   The maximum allowed temperatures is depending on the surrounding material and regulated  by the electrical standards  regulations and directives      Maximum temperature in a floor construction according to electrical standards is 80  C      The general maximum temperature for combustible material is 80  C      Maximum operating temperature for Heating Cable or Heating Mat see the products   technical specifications     The maximum temperature for water membrane are quite low  50  C   see the  producers technical specifications    ZONE 50 complies with the directives for electrical safety and EMC compatibility   ZONE 50 are CE marked and complies with the following standards      EN 61000 6 2  EN 61000 6 3 EN 60730 1 and 60320 2 9   ZONE 50 should only be used when the whole installation complies with electrical standards   regulations  directives and KIMAs installation manuals   ZONE 50 should only be installed by authorized installers   If ZONE 50 have been exposed to violence or got damaged  it should be carefully controlled  by qualified personnel before it will be connected to the mains     Installation floor sensor   It makes it easier if the floor sensor is installed in an end sealed electric conduit pipe  if it  needs to be replaced    The floor sensor should be installed in an open floor area between two heating cables about  0 5 
9. ssssssssssscessscssessssceceeseeeeeeeeees  Functional test  Thermostat is operating when the temperature settings are changed up and down Yes No        Measured current when energizedC  oou  cccccccssssssssssssssesssssscescsssssssssusssessssseeeessnsssssssnsuessssseecssessssssssnseesesseeeees Amp  Drawing or photo showing thermostat and floor sensors  with measurement distance from wall   location   Signature property owner      nnna aaa anan Signature installeri       www kima com    
10. t the switchboard or a manual switch  that could be installed next to ZONE 50    The timer or switch can control more than one thermostat at the same time  Important   to use the right control signal  the signal should be connected via a rectifier diode   see  technical specifications   See Fig  2     Installing ZONE 50   1  Open the plastic front cover and unscrew the screw  The thermostat should not be  opened in any other way    2  Connecting cables  see fig    Terminal 1  Live  L   Terminal 2  Neutral  N   Terminal 3 4  Heaingcable Heatingmat  Maximum Load 3600W 16Amp   Terminal 5 6  Floor sensor  Terminal S  Control signal from external timer or switch to operate Economy function   Day or Night setback or Frost protection if decided to use   PS  Before the Heating Cable or Heating Mat is connected to ZONE 50 the resistance  and insulation properties should be checked  See Heating Cable or Heating Mat  installation manual     3  Install ZONE 50 with the frame against the wall or over a wall box and fix it with screws   Fit the covers     www kima com    4  Don t turn the heating on to early  before concrete or liquid concrete have cured  enough  See manufactures specifications    5  LED light will be red when the Heating Cable Heating Mat is energized  Depending  on the thickness of the floor construction and how low surrounding temperature are  it  will take longer time to achieve set temperatures  If the heat losses are high  it could  be a problem to achieve set temper
11. will turn on again    I  If the temperature in the thermostat will be greater than 70  C it will turn the relay of  for 10 minutes so the temperature will decrease and the LED light will flash red five  times and a error code    E5    will be presented in the LCD display    J  Contact the distributor ZONE 50 has been purchased from     The floor is energized all the time   a  Check that the cables have been connected in the right way and the terminal screws  are tight    b  Disconnect the floor sensor on terminal 5 6 and there will be an error code in the LCD  display    E1     the LED light will flash red once  The same will happened if terminal 5 6  are shortened    c  Check the floor sensors resistance and compare it with the technical specifications   The reading should only change with the temperature    d  Contact the distributor ZONE 50 has been purchased from     Problem programing ZONE 50  see Users manual     Error codes in the LCD display   E1   Sensor fault  The sensor are shortened or disconnected  The LED light will flash red  once    E5   Overheating  The temperature will be higher than 70degree C in the thermostat and  the relay will be switch off for 10 minutes so the temperature will decrease and the  LED light will flash red five times     Programing ZONE 50  See Users manual     Warranty   Installation should be done by an authorized installer according to regulations  directives  and KIMAs installation manual    Time of Warranty  see KIMA Warranty     INS
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User Manual - E&P Hydraulics  Retrouvez toutes les informations en cliquant ici  Samsung E2202 1.77" Black  Installation Manual  BIOS User`s Manual  el manual de instalación  Gunnar Optiks Anime  Westinghouse 52-Inch Specification Sheet  PAL User Manual Installation and Operation GC PAL PAL GC-xt  Benq LCD Monitor FP91E    Copyright © All rights reserved. 