4. 3 Click OK 52 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Buzzer Output Event You can have the STP Sense give a buzz of a specific frequency when it receives the input event This is the Buzzer feature of the STP To set the Buzzer as the output event 1 Click on the arrow near the Output Event list box and select BUZZER 2 Select the buzzer tone sound in the Output Value box You can type in a value between 0 1023 Alternatively you can select the number from the drop down list Add Condition Input Event INPUT 1 ve Output Event BUZZER w Add Output Event Remove this event 3 Click OK Reset Output Event The RESET Output Event will reset the device upon receiving the specified input You can use this for example to turn off an alarm that has been triggered by a previous input event To make RESET as the output event for the STP 1 Click on the arrow near the Output Event list box and select RESET 2 Click OK DISARM O
5. DANGER Indicates warning of possible danger to the life and health of the user if the relevant safety measures are not taken ATTENTION Indicates warning of possible damage to the device software or other material damage if relevant safety measures are not taken STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 1 4 STP Sense s Features and Benefits Some unique features of the STP Sense are Quad Band GSM SMS GPRS allowing you to access and control the STP Sense device via your cellular phone or the Internet An RS232 interface for direct communication with the STP Sense controller as well as for user defined purposes PLC PC GPS to any RS232 device An event report which allows you to make the STP Sense send a report to you via Serial Communication RS232 This way the user can create Word Excel reports based on the data from the STP Internal Li lon rechargeable backup battery for sending a power failure alarm via SMS or GPRS in case the main power supply is cut off Accompanying the STP Sense is the Logic Flow Sense Configuration software package Some features of the Logic Flow Sense program are It allows you to program the STP Sense device to control a system and do the desired controller tasks quickly and efficiently It allows you to monitor your system STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 2 Overview This chapter provides a brief Overview of
6. Folders A File name 9 Configurations_List Save as type Smart Logger cond Y Hide Folders Supply a name in the File name box and click Save The list of instructions will be saved as a file with the extension cond 56 STP Sense User Manual Revision 2 2 rR Duetech Beres Ltd Loading a saved set of instructions The File menu can also be used to load a saved set of instructions To load a saved set of conditions to the STP 1 Click on the File menu at the top of the screen and select Load The Open dialog box will appear prompting you for the name of the condition file that you want to load onto the STP 9 MME ty Seach Bi Organize 889 Views Bi New Folder o Favorite Links jE Computer W Desktop Recent Places jE Computer E Documents E Pictures te Music l Recently Changed E searches di Public Folders A Fle name Configurations List cond smart Logger cond 2 Select the condition file and click on Open The file name of the instruction set will appear in the upper left hand corner of the Logic Flow Sense opening screen Also the instructions from the condition file you selected will appear on the Logic Flow Sense Screen Removing instructions from the list Logic Flow Sense has two options for removing conditions from the list on the screen e Removing all the instructions displayed e Removing individual instructions 57 c STP Sen
7. STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Command Write Logic to Device Writes the list of commands to the STP When you click on Flash an indicator bar at the bottom of the opening screen shows the progress of writing to the STP A screen will pop up telling you that the write was successful or that it failed Read Inputs Updates the user to the state of the digital input result displayed on main screen Configurations Allows you to set the device s e UNIT ID is the identification of the controller maximum character 10 Access Point Name APN for the cellular service providers that require it maximum 18 characters User name that was configured in the SIM CARD maximum 18 characters Password that was configured in the SIM CARD maximum 18 characters To set the number of seconds to delay sending an outgoing call 10 30 sec PIN code of the SIM CARD maximum 10 numbers TCP timeout between 10 86400 sec To enable disable output events To enable disable input output change report to LogicFlow Offset Can change between 40 to 40 degrees Celsius STP Sense Logic Flow Sense Indicators At the bottom of the Logic Flow Sense screen you will see the following indicators e COM1 9600 An indication of the serial port and the baud rate Verifying that there is communication with the STP Sense When you first execute the Logic Flow Sense software you will receive notification that the seria
8. _ GROUP au e Select ALL to allow all callers to activate the STP Sense by calling the device e Select GROUP to allow only callers whose phone numbers are listed in your Phonebook to activate the STP Sense by calling the device e You can also enter in a specific phone number that will be able to call the STP Sense to activate the specified output event Either select the number from the drop down list which are the entries from your Phonebook or type it in manually in the From list box RS232 Input Event You can use a message from any RS232 device to the STP Sense to serve as a trigger You specify the message string to send to the STP and the STP Sense will respond with the specified output To use a text message from the computer to serve as the input to the device 1 Click on the arrow near the Input event drop down list box and select the RS232 input event The Input message text box will appear prompting you for the message to be communicated to the RS232 parallel port on your computer 2 Enter the text of the RS232 message that will activate the output event in the Input Message text box Add Condition Input Event A5232 we Add Output Event Input Message turn boiler onf Output Event TIMER SET v Remove this event 3 In order to send the msg through the COM port you should write the msg in this format MESSAGE 45 STP Sense User Manual Revision 2 2 Duetech Beres Ltd SWHAT IS THE TE
9. and updates the STP Sense as specified Removing a Phone Number from the Phonebook To remove a number from the Phonebook 5 Click on the Phonebook menu in the Logic Flow Sense Opening Screen 3 STP Sense User Manual Revision 2 2 Duetech Beres Ltd The Phonebook window will open displaying the list of saved phone numbers 6 Mark the phone number you want to remove by clicking on the number Phonebook EA ID NUMBER Add 0O 0623123971 Remove ll Import Export Save amp Clase 7 Click Remove The phone number and name will be removed from the list 8 Click Save amp Close to save the changes to the Phonebook Exporting a List of Phone Numbers from the Phonebook into a File To be implemented in future release Importing a List of Phone Numbers into the Phonebook To be implemented in future release Section 4 4 Setting the STP s Input Event For the STP Sense to implement condition sentences you must program the input and output events of the device The Logic Flow Sense software allows for a set of nine different types of inputs and 9 different types of outputs The software has been custom made for the inputs and outputs the STP Sense accepts To select a new input event 1 Click the Add Condition command in the Logic Flow Sense Main Screen to open the Add Condition window 38 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Input Event k Ime NE HIGH E Add Outpu
10. Celsius of 109 730 1 In this wiring diagram the thermistor doesn t require any additional power supply Analog Input a 20 MA NTC NTC Thenmistor Thermistor Lead 1 Lead 2 NTC Thermistor Figure 16 Attaching a NTC or PT 100 thermistor no external voltage 23 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Installing the Digital Input The STP Sense accepts one digital input that must be within the range of 0 24 V DC ATTENTION Be certain not to exceed the maximum input voltage of 24 V DC Exceeding this value may cause irreparable damage to the STP Sense unit Digital Input 3 6 Y Qut Digital Input Terminal Blocks Figure 17 Input Output side of STP Sense illustrating where to attach the digital input to the STP Sense 24 STP Sense User Manual Revision 2 2 Duetech Beres Ltd The following table illustrates the placement of the Digital Input leads Table 5 Terminal Blocks for Attaching the Digital Input Terminal Block Purpose Number negative or ground Connecting the Power Supply Once you have completed all the other installation steps you can attach the power supply to the STP Sense unit The STP Sense operates on the range between 9 24 V DC You have an option of attaching a transformer that converts the wall current to 12 V DC The connector has two bare wires one to be connected to the negative terminal and one to the positive terminal of t
11. Tr TOL CIE espe secrete acta dds E IE AE E dv esse vce av O E AOE T E ON ARAR 43 DM PA T EN e E E E R E ero cevaeeseneteueecestens 43 WUTC OUT Call Input EVEN cesses o sete E I EE AER E aai 44 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd A UL L a a E 45 DSA TDU E CIE oa E E O EN S E 46 STARTO UE VCE a a E E E O S 47 SECTION 4 5 SETTING THE STP S OUTPUT EVENTS ccssssssssscseeecccccccccccsessessssssssseseeeceesesess 47 TE O E eE EA E T E E A E E A T 49 VES E T a A EA E A 50 CERS OU L E e a R E er rrr cree 51 Eara a TOV EE A EA E E E N A 32 MOULCOIN SCG Otipul LVeni sessrisei nir n ennn E E E Eai wy MTC MOI IV CI arses sete oer eta sats bene Basan once ue esa he eae eteee neem ee eee 53 Reset OU PU L VEN rasia a E S E S E S siaee ancuee nore seaneitnsee iedteess Ja P ARM O D TV a EA EEE TE N EE E T S 53 AO O E O a E EEE NE EEEE A E EE E E EE EE 54 SECTION 4 6 EDITING THE STP SENSE INSTRUCTION SET ss sssesesssseseessetseeesetssessrtsssseesseeseeses 55 SAVING SCL OF INSTT UGIIOUS IA ATIE sinisiin E A E E ee eeoinea tories 55 LOGGING a saved set of INSIFUCIIONS sirier tis iere i E EAT AE AA ETO AEE OOE 57 REMOVING IASITUCTIONS FT OM THE TIS eccasesccosnsiacscotncasastadncecsaieudeetsacvanseteebentegaceonteisedondstacseowaeiert 57 Edino TVS TVS UCI OU TAS orrein E AT EAEE n aSa 59 EXPGNGING COUGADSING Te Instruction LAST caccastedesesteosendasedeasentareasavestansastededostsadvessntudeuenetecoanes 59 SECTION 4 7 WRI
12. application will close immediately Form that i already visible cannot be displayed as a modal dialog bos To leave the Set the form s visible property to false before calling show alog program Another warnino ce z an appear witinfo VOU z e write to the device failed Failed These warning screens indicate that something has caused the STP Sense unit to become busy or hang In the event that you encounter either of these warning screens 1 Reset the device by pressing the Reset button on the STP Sense unit The STP Sense device will emit intermittent beeps These beeps allow you to re program the device if the device is busy 2 While the STP Sense is still beeping periodically click on the Write Logic to Device command again When the device stops beeping this indicates that the device has been restored to the Startup state In Startup state you will have to press Reset to attempt the above procedure again If the problem persists contact Technical Support 61 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 4 8 Some Useful Examples Finding out the STP s Phone Number In the event that you received the STP Sense device and don t know the phone number associated with it Logic Flow Sense can help you easily find out the number To find the Phone Number of the STP 1 On the Logic Flow Sense opening screen click on the Add Condition command Set the Input Event as STARTUP Set t
13. eY ama COLZE ILLE Black Tab Figure 6 Side view of STP Sense ATTENTION Do not force the STP Sense onto the DIN rail Forcing the device on the rail may crack the black tab or the STP Sense casing and may seriously compromise the stability of the device DANGER e The device must only be used in rooms that are dry and clean Protect the device from humidity water or heat The device must not be used in environments containing flammable gases fumes or dust Do not subject the device to shock or severe vibrations Connecting the GSM Antenna Screw the GSM antenna included with the STP Sense device onto the STP Sense s antenna SMA connector The antenna serves the same purpose as the antenna of any cellular phone The antenna must be attached for optimal performance of the device 16 STP Sense User Manual Revision 2 2 Duetech Beres Ltd GSM PWR Antenna gy 24 V DC SMA Connector for the GSM Antenna Figure 7 Side View of STP Sense Showing Antenna Connector ATTENTION Detaching the antenna while the STP Sense is powered on may damage the device Installing the SIM Card Open the STP Sense casing by gently pushing in the two tabs at the top where the GSM Antenna is attached or bottom where are the attachments for the digital output and input of the device GSM EETA Antenna gy 24 V DE Tabs on Antenna side of STP Sense Device 000 coocccee Figure 8 An
14. exceeds or goes below a certain value 21 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Analog Input 3 6 V Qut NTC NTC Thermistor Thermistor Lead 1 Lead 2 DC Voltage Source Figure 14 Voltage source attached to the the STP Sense s Analog Input Attaching an Analog Current Input The STP Sense allows you to attach a current input and the STP Sense can be programmed to alert you in the event the current exceeds or goes below a certain value Analog Input 3 6 V Oul NTC NTC Thermistor Thermistor Lead 1 Lead 2 DC Current Source Figure 15 Current source attached to STP Sense s analog input 22 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Attaching a Thermistor to the STP Sense The STP Sense allows you to attach a NTC thermistor whose resistance decreases as the temperature goes up or a PT 100 thermistor whose resistance increases as the temperature goes up The STP Sense can then be programmed 1 To alert you in the event the voltage exceeds or goes below a certain value 2 To report to you the temperature of thermistor See Section 4 8 Some Useful Examples Using the STP Sense as a Temperature Sensor p 63 The NTC thermistor from the SS series is most suited for the STP Sense and should have a resistance at 25 Celsius of 10KQ 1 and B constant of 3435 1 The PT 100 thermistor suited for the STP Sense should have a resistance at 25
15. the To field You can either e Manually enter a phone number in the field or e Click on the arrow near the To field to select a phone number from the Phonebook e lf you select the option CALLER ID the STP Sense will send an SMS back to the person who called the device Add Condition Input Event INPUT 1 HIGH Add Output Event Output E vent To 15468556 we Remove this event 0546865600 Output eee 0523123671 turning on the boiler CALLER ID 50 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 3 Fill in the message text for the SMS in the Output message text box 4 Click OK GPRS Output Event You can have the STP Sense send a GPRS message to you via your Internet server in the event of something triggering the specified input or a power failure The GPRS message is sent to the IP Address or domain name and Port that you specify To set the STP Sense to send you a GPRS message 1 Click on the arrow near the Output Event drop down list box and select GPRS as the output event 2 Supply the IP or the domain name and Port in the To text box The format for the IP PORT combination is IP ADDRESS PORT for example 192 168 1 1 1023 where 192 168 1 1 is the IP Address and 1023 is the Port The IP Address is in the format 0 0 0 0 and the Port is any number up to 65000 The format for the domain name and port combination is DOMAIN NAME PORT the quotation marks are needed For ex
16. the specified input the phone number you supply the STP Sense will receive a single ring To set an outgoing call as the output event 1 Click on the arrow near the Output Event list box and select Outgoing Call as the output event 2 Provide the phone number you wish the STP Sense device to call in the To field Add Condition Input Event INPUT 1 w HIGH w Add Output E vent Output Event OUTGOING CALL To Remove this event If you select the option CALLER ID the STP Sense will send the outgoing call back to the person who called the device
17. will find it useful to be able to identify which device is sending you a particular SMS or GPRS message The UNIT ID option in the Configuration Settings Spreadsheet is what allows you to assign an identifying name to each STP Sense unit In the UNIT ID field type the desired name for your particular STP Sense unit When the STP Sense unit will send an SMS or GPRS data this Unit ID will appear in the display of your phone in case of an SMS The maximum characters you can put is 10 APN User Name Password The Access Point Name APN must also be supplied in case of GPRS use The maximum characters you can put is 18 Outgoing Call Delay s This option allows you to set the amount of delay in seconds between the time the STP Sense sends an outgoing call and then disconnects the call The range of the delay is 10 30 seconds 34 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Pin Code The access code to the SIM card Valid field only if the SIM has a pin code you should enter the same code If your SIM card don t have a pin code than the field is irrelevant Note default pin code is 1234 The maximum total numbers are 10 TCP Timeout 10 86400 s Length of time in seconds that a TCP session connection will remain active without the remote connection sending any data Online Inputs Report Checking this box updates Logic Flow Sense as to any changes in the input and output Enable Output Events Enables disab
18. J45 to DB9 Adaptor Hook up the STP Sense to your computer by inserting the other end of the RJ45 cable into the adapter Attaching the Analog Input The STP Sense allows for three analog inputs e A voltage input ranging from 0 10 V DC e A current input ranging from 4 20 mA e A Negative Temperature Coefficient NTC Thermistor which has a load of 10kQ 1 at 25 C and constant of 3435 1 not included in the STP Sense kit e APT 100 thermistor which has a load of 109 73Q at 25 not included in the STP Sense kit ATTENTION When attaching the inputs be sure to use wire within the range of 24 12 AWG 205 3 31 mm gauge When attaching the analog voltage input exceeding an input of 10 V DC may damage the STP Sense device When attaching the analog current input exceeding a current of 20 mA may damage the STP Sense device 20 STP Sense User Manual Revision 2 2 Duetech Beres Ltd The following diagram and table illustrate the terminal blocks to be used to attach the analog inputs Digital Input 3 6 V Out GND Figure 13 analog inputs interface The terminal blocks used are in the following table Table 4 STP Sense interface Terminal Block Purpose Number 3 6 V Out Auxiliary voltage output power supply ws fo tome provocan pan amma tome tw Tme pen twee Attaching an Analog Voltage Input The STP Sense can be programmed to alert you in the event the voltage
19. M TAUE S 0F ANALOG DC 3 ao 4 ARH FALSE Ha conmacted ETS CTS OTR DSR EnG elo Agh 21 After creating all the logic conditions click on Write Logic to Device in the main toolbar The STP Sense will now respond by reporting the unit s temperature upon receiving an incoming call sounding the alarm when exceeding the maximal specified temperature and turning off the alarm when the temperature of the unit is back to normal 66 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Using the STP Sense s DISARM Option As demonstrated in the previous example you can use the STP Sense to monitor a refrigerator s temperature and to send an alarm message in the event that the temperature rises above a certain value Let s say that you want to defrost the refrigerator for cleaning The user will have to disable the alarm to allow the refrigerator to defrost and not inadvertently set off the alarm The DISARM option allows you to disarm the STP Sense s outputs in this case to prevent it from alerting you of rising temperature To use the DISARM to disable an alarm system 1 In the Logic Flow Sense opening screen click on the Add Condition command 2 Set the Logic Flow Sense input event as SMS and type in the SMS message you wish to send the STP Sense 3 Set the output event as DISARM and select TRUE in the Dox SIF SMS from 05466865600 Turn off the alarm while detrosting bo DISARM TRUE Add Conditi
20. MPERATUR Not connected RTS CTS DTR DSR RING DCD Flash DISARM Input Event DISARM is a useful command when the STP Sense is used for security or alarm system Let s say you want to set an alarm only after you leave the area you wish to secure Setting the input of the STP Sense to DISARM will cancel all output events effectively turning the alarm system off You can then program the STP Sense to turn the alarm on after you leave the area by sending it an SMS or incoming call see Section 4 8 Some Useful Examples 46 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Using the STP Sense s DISARM Option p 67 To use the DISARM input event e Click on the arrow near the Input event drop down list box and select the DISARM input event The value of the input will be automatically set to FALSE canceling any output events Add Condition Input Event DISARM Ww BE Add Output Event Output Event TIMER w SET 1 we Remove this event STARTUP Input Event The STARTUP option allows you to execute the desired output every time the STP Sense is turned on or resets This is a practical feature for example if you want to find out the number stored on the STP Sense s SIM card in order to access the device see Section 4 8 Some Useful Examples Finding out the STP s Phone Number p 62 To use the STARTUP option as input to the STP e Click on the arrow near the Input event drop down list box and
21. OK The logic sentence will appear on the Logic Flow Sense screen as follows Be IF ANALOG C gt 30 bo Send SMS to Oo466ea500 The temperature in the room is too high AN s bo ALARM TRUE For the third task when the temperature is back to normal the STP Sense will turn off the built in alarm 15 In the Logic Flow Sense opening screen click on the Add Condition command 16 Set the Logic Flow Sense input event as ANALOG C 17 Type in or select the maximal temperature in Celsius of the unit in the list box 18 Click on the relational sign and select lt so that the alarm will be turned off when the temperature is below the specified temperature 19 Set the output event as ALARM and set the selected value of the ALARM to be FALSE 65 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Input Event ANALOG C w z Add Output E vent Output Event ALARM vt Remove this event 20 Click OK The logic sentence will appear on the Logic Flow Sense screen as follows 2 IF ANALOG C lt 30 po ALARM FALSE The full set of conditions programmed to the STP Sense will appear as follows OF ew Qhaetech Bees Ltd EAko OA Voltage rabgipt fi CanentArabg leet E Coli OO E P INCOMING CALL From MS46GS5 Bb a Send SHS ip CALLER 10 The Temperature in the rogn is LN 3y auf ANALOG IC gt 3 Bo Send SMS to 0545855500 Temperature in the room tao HIGH AN 3 eo ALAR
22. P Sense Instructions for installing the STP Sense hardware Instructions for installing the Logic Flow Sense software Instructions and examples of using the Logic Flow Sense interface Section 1 2 Uses of the STP Sense The STP Sense owes its name to the fact that it can be used as a remote control sensor device The STP Sense can give you accurate readings of a system s voltage current or temperature However this poses no limitation on the range of uses for the STP Sense You can employ the STP Sense in Security Home and Industrial automation General Warning System Gateway Telemetry solutions Agriculture Climate Monitoring Cooling Control Automation Section 1 3 Safety Advice The STP Sense is designed to be used only under the prescribed conditions Ensure that all the specifications stated in this manual are observed Tampering with the hardware or software or failure to observe the warnings stated in this manual may lead to serious physical injury or STP Sense User Manual Revision 2 2 c Duetech Beres Ltd damage to the device We assume no liability in such cases and any warranty claims will become void The safety regulations specified for the device must be observed during the installation maintenance and use of the device This manual contains special instructions that are important for the safe and proper handling of the device The warning symbols you will encounter in the manual have the following meaning
23. PRS network Therefore a SIM card not included in the STP Sense kit must be inserted before applying power e Programmable The STP Sense is a programmable controller you program its logic by means of the Logic Flow Sense software and write the commands to the device An RJ45 cable communicates with the STP Sense to write the commands from the serial port on your computer to the STP Sense e Indication LEDs The STP Sense has two indicator LEDs a red LED indicating power supply to the device and device s processing and a green LED indicating whether the device is registered with the cellular network e Backup Battery The STP Sense also features an internal rechargeable Li ion backup battery which allows it to send a power failure alarm either via SMS or GPRS in the event that the 9 24 V DC main power fails e Reset button The STP Sense also features a reset button ee Indicator LEDs STP Sense Reset Button Figure 4 Front view of STP Sense showing placement of indication LEDs and Reset Button 13 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 3 Installing the STP Sense Installing the STP Sense is a simple procedure that should take no more than a few minutes This chapter contains instructions for installing both hardware and software Section 3 1 Package Contents The STP Sense unit comes in a kit with the accessories listed in the table below The table lists the contents of the kit a
24. PhoneBook Write Logic To Devicef Read Inputs fConfigurations LOGIC FLOW SENSE Digital Input NTC Analog Input Voltage Analog Input D Curent Analog Input Phonebook Setup The Logic Flow Sense interface allows you to provide the STP Sense with a Phonebook a list of phone numbers of a group of users of the STP Sense Adding a Number to the Phonebook To add a number to the Phonebook 1 Click the Phonebook command in the Logic Flow Sense opening screen The Phonebook window will open 2 Click Add The Phone Number window will open prompting you for the phone number you want to add to the phonebook Phone Number Phone Number COO y 3 Enter the phone number you wish to add to the Phonebook in the Phone Number field and click OK 36 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Phone Number Phone Number The Contact Name window will open Contact Name Contact Mame 4 Enter the name of the owner of the phone number and click Ok The name and phone number will appear in the Phonebook list Phonebook ae ID NUMBER Hame Add 0 home 052312307 Renae Import Export save amp Clase If you close the Phonebook window by clicking on the X in the upper right hand corner the number you have added will not be saved in your computer In order to save the phone number and name click on Save amp Close Logic Flow Sense saves the Phonebook data locally on your computer
25. S message from your mobile phone INCOMING CALL Allows the STP Sense to respond to an incoming call the STP will reject the incoming call and only use the Caller ID if needed RS232 An RS232 message from any capable device for example a computer or a PLC In addition there are three other input events that the STP Sense essentially can send to itself These are shown in the following table TIMER 1 4 Triggers as timer event occurs DISARM triggers when disarm status has changed STARTUP Performs the specified output event when the device is started or if the user presses the Reset button 10 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Output Events The STP Sense allows for nine different types of output events and messages Four of the outputs are to external devices while five are internal events that the STP Sense employs itself The four outputs to external devices are illustrated in the following table Table 2 Outputs from STP Sense Output to External Device SMS An SMS message to your mobile phone GPRS A GPRS message to your TCP IP Internet server OUTGOING CALL Outgoing call to a predefined phone number The STP Sense will make the call and hang up after one ring RS232 An RS232 message to any capable device for example a computer PLC TIMER used to set up a defined amount of time before timer is triggered RESET Resets the device upon receiving the spec
26. STP Sense User Manual Revision 2 2 STP Sense Smart Terminal Plus Sense Stand Alone GSM GPRS Multi Purpose Controller With Logic Flow Sense Configuration Software User Manual Revision 2 2 a po 3 gt z s rares i s 1 i P ji STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Notes The reader is advised to read this manual carefully and to understand its contents before using any devices Warranty claims for damage arising from failure to observe the instructions given in this manual are invalid We accept no liability for consequential damage arising from the failure to observe the contents of this manual Duetech Beres reserves the right to make technical modifications or alterations to this manual at any time without prior notice Various registered trademarks company names and brand names appear in this manual Even if not designated as such the relevant proprietary rights still apply 2009 Duetech Beres Ltd All rights reserved The copyright and proprietary rights in the guide belong to Duetech Beres Ltd It is strictly forbidden to copy duplicate sell lend or otherwise use this guide in any way shape or form without the prior consent of Duetech Beres Ltd This product is based on software developed by Duetech Beres Ltd Redistribution of this manual and its use in binary form PDF are permitted provided that the above copyright notice and this paragraph are duplicat
27. TING LOGIC TO THE DEVICE cescccesceeeeeesceceaeecenecececeaeeceaeeseeeeeneeseaeeneaeens 60 Procedure for Writing the Instructions to the STP u ccccccccsccccccccccccssssecssscecceecaasssseeeeeseeaaaasssseseees 60 Troubleshooting a Failed Write to the STP Sense wi cccccccsccccccccsssccccccceeseeseeeeaaeesseeeeaaeeeeeeesaaneseeeas 61 SECTION 4 5 SOME USEFUL EXAMPLES sporerna ore eE Ea rE EO na rE 62 Findinegeout the SIP ST hone NUN DC vccisivetisxeossacecctwasnsessatddedasatacesssns E A E N R 62 Using the STP Sense s Timer OP OM cosccavcssssashacesactaasanessesacasions sudsasesacasneneslsteiansacacaestsegavaetesaccbaves 62 Using the STP Sense AS a Temperature SCnSOP sccccccccsseccccceecceeececeeeeaeeeeeeeeeaeneseeseeaaeeseeesaaaasees 63 Using the SIP Sense S DISARM Op OM cccuwscssiusSeccsrwsensstaaiternscasdnistauicsivasseaecessigeitlnswewusdeisieanteesteay 67 How to make a cyclic event USING timers ccccccccccsseecccccceeeeeeececaeeeeeeeeeeaeeeeeeeeaaeeeeeeeeasaseeseesaaaaeeseeeas 67 CHAPTER 5 TROUBLESHOOTING cc ceecceceeecenecenseeensecesecenseennenenseceseseaseonsesenes 70 Problem No 1 Strange reading Of temperature ccccccccccccccccseeeccccccasseeeceeaeeseeeeeaaessesssaaaeeeees 70 SOON SUC SCS ILOIS otrscn E E E 70 Problem No 2 Displayed temp decreases while measurement temp increases or vice versa 70 SAM ON SU COC SI VOIIS osoin e E acne S a uidnserteceseue teks 70 Problem No 3 Unable to read or write data fro
28. TION 4 1 GETTING STARTED WITH LOGIC FLOW SENSE cssccesceeeseeeeeceeeeceneeseaeeeneeeeaeens 30 SEP Sense Menus ONG 1 OOl DOI vsscacsssnscasecsasnamidansecssenndesovasseronsantassensavdeeasaaqavenuesonaasaadeneeraaatiesaaanas 31 Verifying that there is communication with the STP S NS ccccccccsssseessececcceceaseeseeceeeseeaaansseeees a SECTION 4 2 CONFIGURATION SEI LIN GS soc ccancepestivageceausantreessanassetaotencasvareeduoreneavenatimenenasen 34 COM SUT QUON Senes SCC CN cis saita sons ta e ab ir 34 SECTION 4 3 READ INPUTS COMMAND scccesceeesseeesecesceceaceeaecesceceaceceaeesaeceaceseaeeseaeeeeeeeeaeens 36 FION TEOL SETUP Ee ee eer eee ener er eee ere ener nee ee er ee ee 36 Adding a Number 10 the PNONCDOOK ciceicivansiseh ccadtdeunsitanancsieeipangeraicenetacsiastectootaetetansencseaniateeoset 36 Removing a Phone Number from the Phonebook icccccccsscccccccssessecccccceseeeeeeeeeeseeeeeaasesseeesaanseeeeas 37 Exporting a List of Phone Numbers from the Phonebook into a File cccccccecccecccesenseseeeeeeneesees 38 Importing a List of Phone Numbers into the Phonebook i cccccsccccccccsssecceccccceneeseecceaasesseeeeaaeesseeens 38 SECTION 4 4 SETTING THE STP S INPUT EVENT scccscassnctastnsacesetncasermonnenenneanaverscnvaenevtesereesianenens 38 D TPG TV CI e E A A A meena 40 Maih POwWer Input EVENT o reiiirse rii irri Ne a EEE E EEEE ANNEE EEE E ASE 4 MRTG E TEV CIE E EN A cece gta Souse ate daw EN EE EE Heese E E eee 4
29. ample www cnn com 80 where www cnn com is the domain name and 80 is the port The port is any number up to 65000 Add Condition Input Event INPUT 1 ka HIGH ka Add Output Evert Output Event GPRS v To E Remove this event Output message turning on the alarm Add Condition Input Event jINPUT 1 we HIGH we Add Output Event Output Event GPRS w To Remove this event Output message HELL 3 Fill in the message text in the Output Message text box The message length should be no longer then 60 English characters 4 Click OK 51 STP Sense User Manual Revision 2 2 Duetech Beres Ltd RS232 Output Event You can have the STP Sense send you an Event Report screen see Section 5 6 of the Logic Flow Sense interface when the STP Sense device receives the input specified This is termed the RS232 Output output delivered via your computer s serial port You can then select the text of the Event Report and paste it into a Word or Excel file To set the RS232 Port as the Output device 1 Click on the arrow near the Output Event list box and select RS232 2 Fill in the message text on the Output Message text box Add Condition Input Event INPUT 1 a HIGH kei Add Output Event Output Event PESE Remove this ewent Output message turning on the alarm 3 Click OK Outgoing Call Output Event You can have the STP Sense send you an outgoing call as the output event When the STP Sense receives
30. ates that the device is registered to the cellular network 26 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 15 16 17 18 19 20 21 22 23 24 5 DOLOVO OOO0OO Red PWR LED Green Register LED STP Sense REG Duetech Beres Ltd OOOO GS GOGGHOO 9 1 11 12 13 Figure 19 Status LEDs in STP Sense Red PWR LED After applying the 12 V DC power supply or inserting the back up battery check that the red PWR LED lights up The red PWR LED indicates that the main power is applied or that the backup battery is properly attached Table 7 PWR LED Indications LED Cr ho Status No indication indication No power power Red blinking When STP unit is sending a SMS or GPRS sa Red steady Poweron on As we ll see later on in the section dealing with the Logic Flow Sense software the red light will flash when the STP Sense sends an SMS or GPRS message Green GSM LED The green GSM LED indicates that the unit registers to the network When you first power up the STP Sense or press Restart the device emits 4 beeps and in a few seconds the green LED lights up The green LED will remain lit continuously for few seconds while the device 2 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd is searching for the cellular network The green LED subsequently flashes periodically while the STP is registered to the GSM network During normal functioning of the device the green LED se
31. e das tere ected N ll Hardware DIGS C71 DU OM sirsie srenti an SEE EEE NEEE EAEE NEEE EE 12 CHAPTER 3 INSTALLING THE STP SENSE 0 cccssccseeecenecensecensecnseneneecnseseaes 14 SECTION 3 1 PACKAGE CONTENTS chic gyeceeeaeencereaceatecoent E uses eenee E E wes 14 SECTION 3 2 HARDWARE INSTALLATION sncesvesssuesvascatasneyvavesieavabesuntionns weauednaetavenscnvevesgeetesneeoateys 15 Mounting the SIP Sense Unilaessssiesrssi isene ea e A e ana a ia Eene Eana 15 Connecing ihe GSM AMENNA sssini eE Eni EE EEE rnEeE e Ei 16 T E A E E E EEE A A O AEA E EE EE E 17 Comme T TE EI E r E E E E E E E ieee 19 Attaching the RJ45 to DB9 AGGDter cccccsessscscccccccccnnnsseeseccccccneasssesscccccecensssseeccceaccnaaseesececeaenonass 19 Alachine he Anal OS INPUT seisot erence clas rE O EATE E OEA O OES 20 Attaching an Analog Current INDut cccccccsssssccccccccccenssscssccccccnecsssesssccecaceaasseseecccaeenssssseceeeacoenass 22 Attaching a Thermistor to the STP S ns iccccccccsccccccccssseccccceeeeeeeeeeesseeeeeeeeaeeseeeeeeaaaeeeeeseaaaseeeseaaaes ei DSTO TE D CA AT EROATEA EA EAE TEE E EE EEPE 24 CONN CENTS INE F OWE SUI siirsi aeei ea a aa ea 25 SEC TON 3 35 TPOPERA TION sssi Seer eer en eee ee ee eee 26 OS TI eenaa a E eas aa A 26 PROSE TI OI caries ace serssateane E se sasaessisors sonic iaceiesgsnadeniatasaan seers A esinise saan 29 CHAPTER 4 USING LOGIC FLOW SENSE ccsscccseccnseeeneecesecensecnsenenseceseseaseneneeeaes 30 SEC
32. e main power Monitors the current of a device to alert ANAEOG ANIA you if it exceeds or goes below a designated value Monitors the voltage of a device to alert ANALOG MYV you if it exceeds or goes below a designated value Monitors the temperature to alert you if it ANALOG C exceeds or goes below a designated value TIMER1 4 Allows for timed input Timers 1 amp 2 count in units of 10 s of minutes and Timers 3 amp 4 count in units of seconds Triggered as a new SMS with a predefined message is sent to the device INCOMING CALL Triggered as an incoming call is dialed to the device Main Power Allows a text RS232 message to trigger the device Triggered as DISARM state is changed by a different event STARTUP Performs the output event upon startup or when you press reset or write to the STP Digital Input Event As mentioned before the STP Sense takes one digital input If the input voltage is between 5 24 V the input is considered HIGH A voltage lower than 0 7 V will be considered LOW To set a digital input 1 Click the arrow near the Input event drop down list box and select INPUT1 2 Choose the desired state from the Status list box Select the input condition as either HIGH or LOW 4dd Condition Input Evert INPUT 1 We Add Output Event Output Event TIMER yt i Remove this event 40 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Main Power Input Event You may want t
33. ed in all such forms and that any documentation advertising materials and other materials related to such distribution and use acknowledge that the software was developed by Duetech Beres Ltd THE SOFTWARE IS PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE STP Sense User Manual Revision 2 2 Duetech Beres Ltd Table of Contents TABLE OF CONTENT eerste aes eee eae vnc es a aaa aaa Eaa 3 CHAPTER 1 INTRODUCTION ccsccsseccsseccsssenseccnsccnseccessensecnsecessecnsseussenassensesonsses 5 FETON Wit OG OS MANUA cciccss co A seuss denyeetantriaereoussenses 5 SECTION 1 2 USES OF THE SIP SENSE scp ciseceiigevayestisaipeaecctaednesehaitenscumayepseencaenadedecunesdameenaharaatereanennds 5 SEC THON Lo SAFEIY ADVICT Speer een eee ee eee eee eee ee ee ee ee 5 SECTION 1 4 STP SENSE S FEATURES AND BENEFITS cccesceeeseeesceeececeaeeeeaeeeeeeceaceceaeenaeeees 7 CHAPTER 2 OVERVIEW sssssenssnnsennennnnnnonnonnnnnnnnnnnnnonnnnnnennennnnnnennennnnnnnnnnnnnnnnnnnnennennnnnn 8 SECTION 2 1 STP SENSE GENERAL DESCRIPTION szavesdciaslenatacadocteddavonsabs entesuadnestetaundesiadeantavars 8 DE CISC PIII SIONS aractnasoneat ne tacarntan E E EE ursenuecessaataee saunas S TPIS ar A cee casat sanaatessea neste E sana uutee vosedeoaaaest weave aeeeeiaiest 10 OU TEV TUS PE N E aston see E EN vane PO seen caw E T E neu
34. ent Analog Input EY Digital Input Not connected RTS CTS DTR DSR RING DCD Flash Figure 21 Logic Flow Sense Opening Screen 30 STP Sense User Manual Revision 2 2 Duetech Beres Ltd STP Sense Menus and Toolbar The following table enumerates the functions on the opening screen of Logic Flow Sense and their uses File Menu Load File Allows you to load a set of conditions to the STP Sense device saved in a cond file Save Allows you to save the conditions you have supplied to the STP Sense device in a cond file Logic Menu Write To Device Writes the list of instructions to the device Read From Device Reads the present list of instructions from the device and displays it on the screen included in future release Erase Device Erases the logic that has been written to the device included in future release STP Sense Toolbar Commands Logic Flow Sense Command COM Port Opens or closes the RS232 serial port connection between the STP Sense device and the computer Add Condition Allows you to add a condition to the list of commands to the STP providing inputs and outputs Remove All Allows you to erase all conditions from the list Note that it removes conditions only from LogicFlow to erase the STP Sense click Write to Device after removing all conditions to update the hardware Phonebook Allows you to store names and phone numbers of users of the STP to receive or send messages to the device 31
35. erature in the list box next to the relational symbol You can either select the value from the drop down list or type in the value Timer Input Event TIMER as an input event allows the STP Sense to respond after a specified amount of time TIMER1 and 2 delay the output response in units of tens of minutes whereas TIMERS and 4 delay the output response in units of seconds value for the timer To use TIMER as the input event e Click on the arrow near the Input event drop down list box and select the TIMER input event Add Condition Input Event IMAR k Add Output Event Output Event OUTGOING CALL e To 0546585600 Ww Remove this event SMS Input Event A useful feature is using an SMS as the input event You can send an SMS to the STP Sense device and that can serve to trigger the STP Sense to give the programmed output To set an SMS message as the input to the STP 1 Click on the arrow near the Input event drop down list box and select SMS 2 Click on the arrow near the From list box and select from the possible senders of an incoming SMS message to the device 43 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Input E went From MEt ieai Add Output Event Input Message Turn the boiler on GROUP Output Event TIMER Remove this event e Select ALL to allow all SMS senders to activate the STP Sense by sending the specified SMS message to the device e Select GROUP t
36. he STP Sense unit The striped wire is connected to the negative or ground terminal and the solid black wire from the transformer is connected to the positive terminal The STP Sense unit has numbered rows of terminal blocks Insert the leads into the appropriate terminal blocks on the side of the STP Sense unit using a 6 mm wide flathead or Phillips screwdriver GSM PWE Antenna OV 24 V DC 4 25 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd The following table shows the correct connections of the transformer to the STP Sense Table 6 Terminal Blocks for Attaching the Power Supply to the STP Sense Terminal Block Purpose Number Holes GND lead from transformer HoletS Positive power supply lead from transformer ATTENTION Ensure the correct polarity of the power supply terminals If using another DC voltage source be certain not to exceed 24 V This will cause irreversible damage to the STP Sense unit The device should be wired in a de energized state Regularly check the live cables to which the devices are connected for faults or breaks in the insulation If any such fault is found immediately turn off the device and replace the wiring Section 3 3 STP Operation Status LEDS The STP Sense has two status LEDs to indicate that you have installed everything properly and that the device is in proper working order The red LED indicates that the device is receiving power The green LED indic
37. he output event as either OUTGOING CALL or SMS If you choose SMS supply an identifying output message Provide your cellular phone number in the To box Add Condition Input Event STARTUP v Add Output Event Output E vent To 0523123987 Remove this event Output message here is the STP Lite s phone number 5 Click OK and save the instruction 6 Click on Write Logic to Device The STP Sense will automatically execute a Startup It will then proceed to send an outgoing call or SMS to the cellular phone number you have provided The Caller ID on your cellular phone will tell you the source of the incoming call or SMS that is the number of the STP Sense device Using the STP Sense s Timer Option When writing to the STP Sense you are able to send several lines of commands The TIMER option allows the response of the system to be delayed by a designated number of seconds or minutes In this manner it is possible to delay the response of the STP Sense so that certain events will occur later in the event of specific inputs To use the TIMER option to delay an alarm from going off for ten minute 1 In the Logic Flow Sense opening screen click on the Add Condition command 2 Set the Logic Flow Sense input event as SMS For sake of this example the alarm will be sounded by your sending the STP Sense an SMS 62 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 3 Set the output e
38. ified input BUZZER Makes the STP Sense unit emit a buzz DISARM disables enables all output events ALARM Makes the STP Sense unit emit a high pitched alarm sound 11 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Hardware Description The STP Sense as the name implies is a Duetech Beres controller to be used primarily as a sensor device giving feedback and control for changes in current voltage or temperature Here is a brief summary of the hardware the STP Sense employs e Packaging The STP Sense is packaged in a small 72 x 90 x 50 mm polystyrene case The casing allows for a DIN rail mount to insure ultimate safety and stability of the device e Inputs The STP Sense allows for one digital input with voltage range between 0 24 V DC and three types of analog inputs voltage current and temperature Main Power Input g 74 V DC yet Connector 114 15 16 17 18 19 20 21 22 3 24 26 POPOVO OQ 9 e STP Sense Duetech Beres Ltd QOOCQOSOOCOOOO 2 E 4 5 amp F 8 40 A41 12 13 Digital Input N NTC Thermistor 3 6 Output Analog 4 20 mA Inputs 0 10 Y DC GND Figure 3 STP Sense s Digital and Analog Inputs e Durability The STP Sense s operating temperature is between 30 C to 85 C allowing it to withstand the harshest conditions 12 STP Sense User Manual Revision 2 2 gt R Duetech Beres Ltd e GSM technology The STP Sense device is based on GSM G
39. instruction list that you want to modify 2 Inthe list of commands select Edit The Add Condition box will reappear with the original input and output events associated with this instruction 3 Make the desired modifications to the Input and Output events and click OK Expanding Collapsing the Instruction List When the number of output events becomes large the instruction set may start to appear more complicated In order to make the logic written to the device more manageable Logic Flow Sense has an option to expand or collapse all or some of the instructions in the instruction list To expand collapse the instructions in the instruction list e Right click anywhere on the Logic Flow Sense Screen The Editing options box will appear aa INPUT 1 HIGH bo DISARM TRUE a F Teele Edit Remove Collapse All Expand All e To expand all the instructions showing the input and output events click on Expand All e To collapse all the instructions click on Collapse All e To expand an individual instruction click on the symbol next to the input event e To collapse an expanded item click on the symbol next to the input event 59 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 4 7 Writing Logic to the device Procedure for Writing the Instructions to the STP Once you have specified the inputs and outputs to the STP Sense in the Logic Flow Sense software you now have to wri
40. is SMS as a cyclic event to the STARTUP input event we ll have to add another output event that will be the TIMERS the number 0 254 that you ll put in the timer will be the time period of the cyclic event 5 In order to make a 2 minutes period we ll set the TIME3 to 120 seconds Input Event TIMERS Add Output Event Output Event SMS i Remove this event Output message the temperatur is AN 3 Output Event TIMER3 6 After creating all the logic conditions click on Write Logic to Device in the main toolbar 68 STP Sense User Manual Revision 2 2 T Duetech Beres Ltd The full set of conditions programmed to the STP Sense will appear as follows File Logic About Com Port Add Condition Remove All PhoneBook Write Logic To Device Read Inputs Configurations er LOGIC FLOW SENSE o 51 Sense Digtal Input NTC Analog Input Voltage Analog Input K Current Analog Input K Bo Set TIMER3 to 2 Seconds F TIMERS Interrupt Send SMS to 0528849306 the temperatur is AN 3 Bo Set TIMER3 to 120 Seconds Not connected RTS CTS DTR DSR RING DCD Flash 69 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 5 Troubleshooting Problem No 1 Strange reading of temperature The unit with the NTC sensor shows strange readings at room temperature For example at room temperature of 24 degrees Celsius the unit shows 46 degrees Celsius Solution suggestions Check if the
41. k the connection of the antenna f your SIM card is protected with a pin code you need to enter the code in the configuration window and write it to the device Check the APN in the configuration window see if it matches your SIM card Problem No 6 Led s not working Solution suggestions Check the polarity power to the unit After startup you hear 4 beeps and you see no lights on Than the led s are burned out n case the unit is on battery check the volts Maybe the battery is empty 12 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 6 For Further Information For more information about our products recommendations for accessories components online documentation and updates please visit our website www duetech gberes com Revision History Date Rev Author 16 04 09 Initial Draft Yehudah Posnick 10 05 09 Yossi Grimberg 13 07 09 Yehudah Posnick 19 07 09 Yossi Grimberg 09 12 09 Yaron Babar 73
42. l port is not connected to the STP Sense 32 STP Sense User Manual Revision 2 2 eme Duetech Beres Ltd Device is not connected Mok connected RTS CTS DTR DSR RING DCD Flash f 1 Click on the command COM Port in the opening screen The Serial Connection dialog appears prompting you to open the COM Port This enables communication between your computer and the STP Sense device enal Communication x Baud Rate 2 If there are several serial ports on your computer select the appropriate one from the drop down list near Port and type in the Baud Rate 3 Click Open Port The bottom left area of the opening screen will indicate the COM Port and the baud rate Device is now connected to ete 1 at 9600 COML 9600 RTS CTS OTR DSR RING DCD Flash 33 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 4 2 Configuration Settings Configuration Settings Screen UNIT ID Empty Online Inputs Report Help Box W Enable output events Offset 0 APN Empty User Name Empty Password Empty Outgoing call delay s Empty FIN CODE Empty Tep Timeout 10 86400 6 Empty Read Configurations From Device Write Configurations To Device Close When you click on the Configurations command in the Logic Flow Sense opening screen the Configuration Settings screen will open up Fields in the Configuration Settings Screen UNIT ID lf you employ several STP Sense devices you
43. les output event execution similar in function to DISARM command see p 46 DISARM Input Event Offset A calibration factor that lets the user adjust the temperature reading and calibrate it duo to sensor wire length The value can be configured as a negative or positive number and the final temperature output will be implemented with the offset and the measurement The range of the offset is 40 to 40 degrees Celsius Help box A short explanation brief of every configuration setting Once you point your mouse on a setting you get an explanation Configuration Settings Commands Read Configurations from Device This allows you to read the device s configuration to check if the configuration is in order or if you need to know a specific parameter for example the Unit ID Write Configurations to Device Clicking on this writes the selected configurations to the STP Sense device 35 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 4 3 Read Inputs Command The Read Inputs command on the Logic Flow Sense main screen is an option that allows you to know the status of the digital and analog inputs of the STP Sense This information about whether the digital input is HIGH or LOW and the values of the analog inputs 0 1023 value for Voltage Current inputs and Celsius degrees for NTC will be displayed on the main screen above the instruction set list File Logic About Com Port Add Condition Remove All
44. m the configuration MENU cseeecceeeeeeeeeees 71 DOL EIOM SUC OCG LOIS E T A E A E EE EA A N E E 71 Problem No 4 Can t send receive calls SMS GPRS u c cccccceccsccesccssccsccsccesccsceuccuscesccuscesceusees 71 OI ON SUS CSN A yenasecsaanecstense nese 71 Problem No 3 preen led 1S CONSTANTLY OM biccavrassvicuaseVosacesissraviactasacdentdeatesatenaveadessanoaa ecanvetdseanesas 72 SA OTS SG TOI cece cast seis enteeseee E vent S E eos acer E oes eceascncnee eed 72 Froben No O Lea 8 MOL VOTO ari an E E E A E E E E AS ZZ SOMON SUC OCS OIA or eE E E ot geass een castes alte am eau altel Glew E TA unin ashiors Fz CHAPTER 6 FOR FURTHER INFORMATION ccsscceeeeceseccnsecnsenenseceneeenseneaes 13 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 1 Introduction The STP Smart Terminal Plus Sense is a user friendly general purpose GSM GPRS cellular programmable controller The STP Sense can be used for a wide variety of purposes agriculture home automation or security The STP Sense accepts one digital input and three different types of analog inputs e Voltage e Current e Thermistor Section 1 1 About This Manual This manual will guide you through the setup and major uses of the Smart Terminal Plus Sense STP Sense a powerful remote control and monitoring device This manual includes A list of the uses of the STP Sense STP Sense s features and benefits A general description of the ST
45. nd their part numbers Table 3 Package Contents Description Description QTY P N STP Sense Controller Unit B STPS0001 Power Supply 12 V DC Voltage PS220121 Transformer DIN Rail B STP00701 RJ45 Cable Connects the RJ45RJ45 STP Sense to the serial RS232 port of the computer RJ45 to DB9 converter The CORJ459F DB9 converter allows a connection to the 9 pin serial port of the computer GSM Antenna EE AP001A00 GSM Antenna 90 degrees ES RUBOO9A CD of Documentation and CDROOO1 Logic Flow Sense installation software 14 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 3 2 Hardware Installation The installation of the STP Sense can be completed in minutes You will need a pocket screwdriver not supplied in the kit to attach the power supply and digital input A 6 mm wide Phillips or flathead screwdriver will do Mounting the STP Sense Unit Mount the STP Sense by pushing or snap fitting it onto a DIN rail top hat rail 35 mm Pull out the black tab on the STP Sense device using a screwdriver and snap the device onto the DIN rail Ensure that the retaining mechanism of the STP Sense snaps cleanly and securely onto the DIN rail J134 15 16 17 18 19 20 21 22 23 24 25 OOO00 0 OOO0OO STP Sense Cc RESET Duetech Beres Ltd Black tab DIN rail Figure 5 Top view of STP Sense attached to DIN rail 15 STP Sense User Manual Revision 2 2 Duetech Beres Ltd gt O uo
46. nt 1 Click on the arrow near the Output Event list box and select TIMER1 TIMER2 TIMERS or TIMER4 The following screen capture has all the timers employed as output events Add Condition Input Event INPUT 1 w 2 Add Output Event Output Event TIMER Remove this event Output Event TIMER Remove this event Output Event TIMERS Remove this event Output Event TIMER4 Remove this event Cancel 2 Inthe SET box type in the timer duration Again for TIMER and 2 the number entered will be in increments of 10 minutes of delay between the input and output event For TIMERS and 4 the number entered will be seconds of delay The value must be between 1 254 3 Click OK 49 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Com Port Add Condition Remove All Phonebook Write Logic To Device Read Inputs Configurations LOGIC FLOW SENSE NTC Analog Input Voltage Analog Input Curent Analog Input Ma Digital Input a IF Teo lei bo Set MER to 30 Minutes BO Set TIMERS to 40 Minutes DO Set TIMERS to 5 Seconds D0 Set TIMER4 to 6 Seconds SMS Output Event You can set the STP Sense to send you an SMS message when the device receives the specified input To use the SMS Output Event 1 Click on the arrow near the Output Event list box and select SMS as the output event 2 Enter the destination phone number the number that is to receive an SMS message from the STP Sense device in
47. o allow only SMS senders listed in your Phonebook to activate the STP Sense by sending the specified SMS message to the device e You can also enter in a specific phone number that will be able to send an SMS to activate the specified output event Either select the number from the drop down list which are the entries in your Phonebook or type it in manually in the From list box 3 Enter the text of the SMS message that will serve to activate the device in the Input Message box The message length should be no longer then 60 English characters Add Condition Input Event SMS w From 0546885600 Add Output Event Input Message Turn the boiler on N lEn TIMER ET Remove this ewent Incoming Call Input Event Just as you can set an SMS message to be the trigger of the STP Sense device you can also use an incoming call to serve as the trigger You will hear the phone ring as you try to make the call and the call will be rejected it is recommended that you cancel the voice mail via the GSM provider The STP Sense has successfully triggered the STP To set an incoming call as the input to the STP 1 Click on the arrow near the Input event drop down list box and select INCOMING CALL 2 Click on the arrow near the From list box and select from a list of possible callers to the device 44 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Output Event 4J 0523123871 Remove this event
48. o be alerted if the STP Sense device gets disconnected from the main power and is now running on the backup battery You may want to be alerted if the main power is restored The Main Power Input Event is designed for this purpose To set Main Power as an input event 1 Click on the arrow near the Input event drop down list box and select the Main Power input event 2 Select in the list box next to the sign whether you want the STP Sense device to alert you when the Main Power is disconnected LOW or reconnected HIGH Add Condition Input Event HIGH ae Add Output Event HIGH Ki Dutput Event TIMER w guwo se Remove this event Analog Input Event As mentioned before the STP Sense takes three types of analog input Voltage Current and Thermistor We will now examine the settings of these inputs in turn To set the current analog input 1 Click the arrow near the Input event drop down list box and select ANALOG mA 2 Click on the relational symbol to open up a drop down box that allows you to select whether you want the STP Sense to react upon receiving an input greater than equal to or less than a specified value 4dd Condition Add Output Event Remove this event 3 Supply the value in the list box next to the relational symbol You can either select the value from the drop down list or type in the value 41 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Inpu
49. on Input Evert EE From 0546885600 8 Add Output Event Input Message Turn off the alarm while defrosting Output Event DISARM w Remove this event The STP Sense will thus disable the alarm upon receiving your SMS If you want to enable the alarm by means of an SMS message simply set the DISARM value to FALSE 4 Click OK and click on Write Logic to Device How to make a cyclic event using timers When you want to make a repeated output du to a singel event you can make a cyclic program easily In this example the user wants to send an SMS every two minutes as a trigger to input event To do so you need to use TIMER 3 or TIMER 4 because they are counting in seconds TIMER1 amp TIMER2 counts in 10 s of minutes To make a cyclic event you need to make two input events 1 The first input event will be anything you want from the input event list except the TIMER S 67 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 2 Lets configure the ANALOG C gt 25 as input event This means that when a temperature larger than 25 degrees will trigger the procedure 3 For the output event we ll configure the TIMERS to 2 seconds Add Condition Input Event ANALOG C Add Output Event Output Event TIMERS Remove this event 4 Next input event will be the TIMER3 and the output events will be an SMS or GPRS message or any output event from the list We ll choose an SMS In order to make th
50. puter is ok and every thing is connected flawlessly Problem No 4 Can t send receive calls SMS GPRS When you have a trigger response that needs to send an sms or make a call or send a GPRS message and you aren t receiving it There can be some problems making this situation Solution suggestions General suggestions Check if the antenna is connected properly Check if the sim card is placed in the sim card holder properly Checks if the destination phone is able to receive sms s or open to incoming calls Check the green led and see if the light is on constantly If so see problem No 5 SMS suggestions If you see that an SMS is sent the red led is flashing and the program wrote that SMS has been sent and you didn t receive it immediately wait for a couple of minutes maybe the mobile phone network is busy and it takes time Check in the SMS output event the phone number see if it matches the desired number Call suggestions Check if the phone number you entered is correct 11 STP Sense User Manual Revision 2 2 Duetech Beres Ltd GPRS suggestions Check if the IP and address is correct and the target destination is open to that port Check if the APN user name and password at the configuration window is correct and suitable for the sim card Problem No 5 green led is constantly on After the startup of the unit the green led is constantly on instead of blinking Solution suggestions Chec
51. rature measurement via a formatted SMS text message Task 2 When the temperature is higher than a pre defined value the STP Sense will send a formatted SMS alarm text message and turn on its internal audible alarm 63 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Task 3 When the temperature is back to normal the STP Sense will turn off the internal alarm To set up STP Sense as a temperature sensor For the first task reporting the temperature in the room in response to an incoming call 1 Inthe Logic Flow Sense opening screen click on the Add Condition command 2 Set the Logic Flow Sense input event as Incoming Call 3 Supply the number s of the person s who can find out the temperature of the unit upon calling the STP Sense 4 Set the output event as SMS and have the message sent to CALLER ID so that the caller to the STP Sense be the one to receive the SMS reporting the unit s temperature 5 Inthe Output message box supply the text of the SMS message the STP Sense is supposed to give and select AN 3 or AL 3 as the analog value of the temperature that the STP Sense unit will report Add Condition input Event MEREEN v Fron Output message 6 Click OK The logic sentence will appear on the Logic Flow Sense screen as follows E WF INCOMING CALL From 0546885600 bo Send SMS to CALLER ID The temperature in the room is AN 3 For the second task reporting with an SMS message when
52. rm on and FALSE to turn the alarm off Add Condition Input Event INPUT 1 jm HIGH Add Output E vent Output Event ALARM TRUE we Remove this event l TRUE FALSE 3 Click OK 54 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Section 4 6 Editing the STP Sense Instruction Set Saving a set of instructions in a file After you have supplied a series of instructions to a particular STP Sense device you might want to save it for later use For example if you move the STP Sense unit temporarily to a different circuit you will want to restore the previous set of instructions when you go back to the first device Logic Flow Sense has a facility for this in the File menu To save a set of instructions 1 Click on the File menu at the top of the screen and select Save AS Logic Load File About ition Remove All PhoneBook Write Logic To Device OGIC FLOW SENSE Save Digital Input NTC Analog Input Voltage Analog Input D Curent Analog Input DJ 99 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd The Save As dialog box will open prompting you to give a name to your compilation of instructions a Save As K a Dustech Beres STPS Search Bi Organize se Views i New Folder _ Date modified This folder is empty avorite Links Computer Desktop eel Recent Places jE Computer E Documents Pictures R Music 4 Recently Changed More gt
53. rves as the modem registration indicator This light is on when the modem powers up and flashes when the STP Sense is registered with the cellular network Table 8 Green REG LED Indications LED Indication Operation Status Green steady Device is searching for the network connection Green blinking Connected to a network 28 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Reset Button To reset the device use the reset button It can be useful for reconfiguring the device in case of wrong logic after resetting the device use has 5 seconds of Safe Mode without any logic running ges 16 17 18 19 20 7 x 23 24 25 B OOOO0O0 OIL Reset Button gt o STP Sense E3 Duetech Beres Ltd OOOCOCOOAAOOCOCO 1 2 3 4 5 6 F 6 9 10 11 T2 13 Figure 20 STP Sense Reset Button 29 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Chapter 4 Using Logic Flow Sense This chapter provides detailed instructions for configuring and using the Logic Flow Sense Software that comes with the STP Sense unit Section 4 1 Getting Started with Logic Flow Sense When you click on the Logic Flow Sense Platform icon on your desktop or in the Start taskbar the program s opening screen appears displaying the menus EE Logic How File Logic ComPort Add Condition Remove All PhoneBook Write Logic To Device Read Inputs Configurations LOGIC FLOW SENSE NTC Analog Input OC Voltage Analog Input Curr
54. se User Manual Revision 2 2 Duetech Beres Ltd Remove all the instructions displayed on the screen After you ve saved the previous set of instructions on the screen you want to configure the STP Sense from scratch You will first have to erase all the conditions presently on the screen To remove all the instructions on the screen 1 From the menu at the top of the screen click Remove All You will receive a prompt asking you to verify the erasure Remove Are vou sure 2 Click Yes All the instructions on the screen will be erased Remove selected instructions To remove selected instructions 1 Right click on the instruction you want to remove from the list A box of editing options will appear LOGIC FLOW SENSE NTC Analog Input Voltage Analog Input DI Curent Analog Input D Digital Input a r NCOMING CALL From 0546885600 2 room is AN 3 Do Send SMS to 0546885600 The 1 BaF ANALOG C gt 30 aasa po Send SMS to 0346885600 Thet end al room is too high AN 3 Do ALARM TRUE g IF ANALOG C lt 30 bo ALARM FALSE Remove 2 Click Remove The selected condition will be erased from the display 58 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Editing the Instruction List If you want to modify one of the instructions to the STP Sense Logic Flow Sense has a convenient editing feature To edit the instruction list 1 Right click on the Input event in the
55. select the STARTUP input event Once this is set as the input event any startup of the STP Sense will execute the output event Startup will consist of e Turning on the power to the STP Sense e Pressing the reset button on the unit e Clicking on the Write Logic to Device command e Asaresult of a RESET event Section 4 5 Setting the STP s Output Events After configuring the desired input event for the STP Sense and selecting the number of output events you want the STP Sense to control you now have to select the type of output event The Logic Flow Sense software allows for 9 different output event options from which to choose 47 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Table 10 Logic Flow Sense Output Events Output Type Description _ TIMER1 4 Sets Timer to a predefined value Timers 1 amp 2 count in units of 10 s minutes and Timers 3 amp 4 count in units of seconds Sends an SMS message from the STP Sense when triggered Sends a GPRS message from the STP Sense when triggered Sends a text RS232 message to the Logic Flow Sense interface when the STP Sense is triggered OUTGOING CALL Initiates an outgoing call when the STP Sense is triggered Emits a buzz at a certain specified frequency when triggered RESET Performs a reset of the STP Sense upon receiving the specified input Useful in implementing an alarm system allows you the choice of enabling disabling the alarm ALARM So
56. t E vent Output Event TIMER w SET Remove this event In the Input Event drop down list you see a display of all the input event options The other fields adjust automatically according to the type of input event selected A single input event to the STP Sense can control up to four output events in any one instruction sentence For example upon receiving the given input event such as a device exceeding range of operating temperature the STP Sense unit can turn on a cooling system and alert you by an SMS an incoming call and a GPRS message over the Internet 2 If you want more than one output event click on Add Output Event Output Event TIMER Ww SET Remove this event Input Event PR Add ma Evert The Add Condition window will expand to accommodate another Output Event 3 If you choose to remove one of the output events click on Remove this event Add Condition Input Event INPLIT 1 HIGH Add Output Event Output Event BUZZER yt ee Remove this ewent Output Evert To 0546885600 wv er this event Output message Temperature too high Here is a brief description of all the input events that are possible Table 9 Logic Flow Sense Input Events Input Type INPUT1 Digital input into the STP Sense device Can take the value HIGH or LOW 39 STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Triggers the output event when the device is detached LOW from or is reattached HIGH to th
57. t Event ANALOG m w 25 Add Qutput Event Output Event OUTGOING CALL E Remove this event 32 Note The value that you provide in the list box is in bits where the maximal current 20 mA corresponds to 1023 bits and the minimal current 4 mA corresponds to 204 bits Similarly wnen you specify that an SMS RS232 or GPRS message should report the input current the value that the STP Sense will report ranges from 204 1023 bits not from 4 20 mA To set the voltage analog input 1 Click the arrow near the Input event drop down list box and select ANALOG mV Add Condition Add Output Evert Remove this event 2 Click on the relational symbol to open up a drop down box that allows you to select whether you want the STP Sense to react upon receiving an input greater than equal to or less than a specified value 3 Supply the value in the list box next to the relational symbol You can either select the value from the drop down list or type in the value To set the temperature analog input 1 Click the arrow near the Input event drop down list box and select ANALOG C 42 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 2 Click on the relational symbol to open up a drop down box that allows you to select whether you want the STP Sense to react upon the thermistor s temperature being greater than equal to or less than the specified temperature 3 Supply the cut off temp
58. te the commands to the device This is performed using the Flash command Event Report To write the instructions to the STP 1 When you have completed adding input and output conditions to the STP Sense write the conditions and setups to the controller by clicking on the Write Logic to Device option in the main screen When you click Ok you will receive the Flash Phonebook prompt Hash Phonebook Flash Phonebook Click Yes The status bar at the lower part of the Logic Flow Sense opening screen will show the progress of the writing to the STP and you will be informed that the program is flashing the Phonebook 16 12 26 546 gt EndSession 16 12 26 578 LogicContigD one Status Bar UNIT ID COM1 9600 RTS CTS OTR DSR RING OCD Flashing Phonebook Se eee seen e ne If the write to the device was successful you will receive the prompt Flash Success Flash Success 60 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Troubleshooting a Failed Write to the STP Sense If the write to the device was not successful you will receive a warning box prompting you either to leave the program or to ignore the problem and continue running the program LogicHow 2 0 A TO IGONE Me problem and Unhandled exception has occurred in your application If you click continue the Continue the application will ignore this eror and attempt to continu If program you click Quit the
59. tenna side view of STP Sense unit showing the tabs for opening the device 17 STP Sense User Manual Revision 2 2 oc Duetech Beres Ltd Digital input 3 6 V Qut Tabs on Input Output side of STP Sense Device Figure 9 Input Output side view of STP Sense unit Place a SIM card in the SIM card holder moapespogsgt iT ve iia am ee teo a rr sorouso OAN N SIM Card Slot Figure 10 slot for the SIM card 18 STP Sense User Manual Revision 2 2 Duetech Beres Ltd ATTENTION e Do not insert or remove the SIM card when the power supply or backup battery is attached Doing so might result in damage or loss of data on the SIM card e Avoid touching the contacts of the SIM card The SIM is sensitive to electrostatic discharge If you are installing a used SIM card insert the SIM ina mobile phone first to ensure that the SIM doesn t contain any saved SMS messages These messages may cause the STP Sense to malfunction Connecting the RJ45 cable Connect the RJ45 cable supplied with the STP Sense to the STP Sense unit via the socket labeled COM Digital Input 3 6 V Out Female RJ 45 pin Figure 11 View of STP Sense showing the RJ45 socket COM Attaching the RJ45 to DB9 Adapter Attach the RJ45 to DBY adapter the 9 pin RS232 port on your computer 19 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Female RJ45 8 pin Female DB 9 Figure 12 R
60. the temperature exceeds a certain value and turning on the STP sense s internal alarm 7 Inthe Logic Flow Sense opening screen click on the Add Condition command 8 Set the Logic Flow Sense input event as ANALOG C and type in or select the maximal temperature in Celsius of the unit in the list box 9 Select gt for the relational sign so that the SMS will be sent and the alarm sounded upon exceeding the specified temperature 10 Set the output event as SMS and have the message sent to a selected phone number or group of numbers 64 STP Sense User Manual Revision 2 2 Duetech Beres Ltd 11 In the Output message box supply the text of the SMS message the STP Sense is supposed to give and select AN 3 or AL 3 as the analog value of the temperature that the STP Sense unit will report Add Condition Input Event ANALOG C w Add Output Event Output E vent To 0546885600 v Remove this event Output message The temperature in the room is too high L4N 3 f 12 Click Add Output Event Another line will appear in the dialog box allowing you to add another output event 13 Set the second output event as ALARM and set the selected value of the ALARM to be TRUE Add Condition Input Event ANALOG C ww gt Add Output E vent Cutout Event To 0546885600 a Remove this event Output message The temperature in the room is too high L4N 3 Output Event Remowe this event 14 Click
61. the STP Sense and includes the following e General Description e Hardware Description Section 2 1 STP Sense General Description The STP Sense is a stand alone multipurpose terminal with extended logic control with cellular capabilities The STP Sense accepts one digital input and three analog inputs E slm O 15 16 17 18 19 20 21 22 23 24 25 243mm OOO0O0 0 OOOOO STP Sense Dimensions STP Sense y 90 mm Duetech Beres Ltd 7 Fr r VCO OO0G BO GOOOE 9 10 11 12 13 Figure 1 Front View of the STP Sense STP Sense User Manual Revision 2 2 Duetech Beres Ltd 24 3 mim 41 4 mm 234 3 mm 15 4 m 5 4 mm 21 mm 50 mrmi 28 mm 27 9 mme 35 mm 40 mm Figure 2 Side View of the STP Sense Showing Dimensions STP Sense User Manual Revision 2 2 c Duetech Beres Ltd Inputs The STP Sense supports nine different types of input events six external and three internal Table 1 STP Sense Inputs External Input DIGITAL INPUT A digital sensor These can include e Thermostat e Motion sensor ANALOG INPUT An analog sensor 0 10V 4 20mA NTC These can include e Hygrometer humidity sensor e Fluid level sensor e Thermistor measures change in temperature MAIN POWER The STP Sense can be programmed to alert you if the main power supply to the STP Sense has been interrupted and the device is running on the Li ion backup battery SMS An SM
62. unds an alarm when triggered Syntax of STP Sense Text Messages If you want the STP Sense to report the digital or analog input values the following syntax should be used in the text message Input Type AN 3 AL 3 In the following example the STP Sense is programmed to report the output temperature in an SMS message AN 3 is the syntax in square brackets and caps lock on to supply the temperature of the thermistor in the SMS message AL 3 acts like AN 3 but the difference is that AL 3 will show the last sampled value that made the trigger to react while AN 3 will show the sampled value during the execution of the output event 48 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Add Condition Input Event EEA From O546885600 v Add Output Event Output Event To CALLER ID y Remove this event Output message The temperature in the room is 4N 3 Upon clicking OK the following logic statements appear in the Logic Flow Sense screen E WF INCOMING CALL From 0546885600 bo Send SMS to CALLER ID The temperature in the room is AN 3 Again the temperature of the thermistor will replace the AN 3 in the SMS message Timer Output Event Sets Timer to a predefined value Timers 1 amp 2 count 10 minutes per unit and timers 3 amp 4 count 1 second per unit See Section 4 8 Some Useful Examples Using the STP Sense s Timer Option p 62 To use the Timer Output Eve
63. unit has the latest version of software Check if the logic flow is updated to the right version Check if the resistance of the sensor at room temp of 25 degrees Celsius is 10K KO 1 Check the Offset and make sure if its on O or other desired value Check if the supplied voltage from the power supply is 3 6V dc Problem No 2 Displayed temp decreases while measurement temp increases or vice versa While measuring high temperature the displayed temperature is showing low temperature or vice versa Solution suggestions Check if you installed the right sensor to the right unit type The most common case is when a pt 100 sensor is connected to a STPS NTC unit or the opposite case Check if the temperature sensor you have is as recommended see p 23 70 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Problem No 3 Unable to read or write data from the configuration menu Solution suggestions In case that the unit is not new have been used before press the reset button and right away click on the read or write configuration to device There is a five seconds window timer that lets you read or write to the device before it starts to configure itself If you missed the five seconds window you could do the reading or writing after the unit finished restarting Check if the reading or writing request is not preformed during SMS sending or call making Check if the connection from the unit to the com
64. utput Event DISARM is a command that is useful in implementing an alarm system Let s say you have a sensor set as the input to the STP when someone triggers the sensor an alarm will sound If you use DISARM as the output event you can voluntarily arm or disarm the security system so that it sounds off the alarm only at specific times See Section 4 8 Some Useful Examples 53 STP Sense User Manual Revision 2 2 Duetech Beres Ltd Using the STP Sense s DISARM Option p 67 To make DISARM as the output event of the STP 1 Click on the arrow near the Output Event list box and select DISARM 2 Set the DISARM value you want to set in the box Add Condition Input Event INPUT 1 wt HIGH ka Add Output Event Output Event DISARM w Remove thiz event e TRUE Disarms the system turns off the alarm when receiving the specified input e FALSE Enables the alarm system to detect trespassers when receiving the specified input e TOGGLE Alternates between the TRUE and FALSE state upon receiving the specified input event 3 Click OK Alarm Output Event You can use the STP Sense device as an alarm When you set ALARM as the output event the STP Sense will emit a high pitched alarm sound until you reset the STP Sense device To set ALARM as the output event 1 Click on the arrow near the Output Event list box and select ALARM 2 Setthe alarm status in the list box Select TRUE to turn the ala
65. vent as TIMER1 supply the number of minutes of delay you wish to program into the device and click OK As mentioned before TIMER1 and 2 allow for delays in units of tens of minutes whereas TIMER3 and 4 allow for delays in units of seconds a IF SMS from 0523123371 Delay the alarm by one minute bo Set TIMER to 1 Minutes Add Condition Input Event From 0523123871 v Add Output Event Input Message Delay the alarm by one minute Output Event TIMER w SET Remove this event 4 Click on the Add Condition command 5 Set the Logic Flow Sense input event as TIMER1 and the Output Event as ALARM and click OK The second line of the command to the STP Sense will appear on the screen a IF SMS fram 0523123871 gt Delay the alarm by one minute bo Set TIMER to 1 Minutes a IF TIMER Interrupt bo ALARM TRUE Add Condition Input Event UMG Sa ka Add Output E vent Output Event ALARM w TRUE v Remove this event 6 Click on Write Logic to Device Upon your sending the specified SMS to the STP Sense the STP s alarm will go off in one minute or any amount of delay that you choose for the unit Using the STP Sense as a Temperature Sensor In this example the STP Sense is employed as a temperature monitor and controller as well as an alarm The STP Sense is programmed to perform three tasks Task 1 When a user calls STP Sense the unit will reject the incoming call and send back the tempe