Home
        WL-410/XB Wireless Wind Alarm System User Guide
         Contents
1.       WL 410 XB  Wireless Wind Alarm  Svstem    Instrument at a Glance  Overview    Sensor  amp  Receiver   Sensor   Receiver   Bluetooth  WL 410XB only     Display   First page   Second page   Third page   Restore receiver to default    Settings   Setting of parameters  Max alarm   Pre alarm 2   Pre alarm 1   General settings    Technical Specification  Instrument    Safety  Handling   amp  Maintenance  Important safety information  Important handling information  Packing list   Accessories  amp  spare parts  Standard    Warranty  amp  Services  Warranty conditions  Services    NO    O CO OO OO NOB A UW Ww        ed  N   OoOO        m  W Ww                    eee  UMUWUMhkRhA      oe    Ov OV    OV    Instrument at a Glance    Overview   WL 410 XB Wireless Wind Alarm Svstem consists of a wind speed sensor and a receiver  The sensor  measures wind speed and transmit data to the receiver  The 3 5 inch LCD displav of receiver shows  readings on the main page and the historv graphs are shown in different pages  According to the  preset values  the receiver can trigger local alarms such as LED lights and buzzer  or trigger external  indication via 3 built in relavs when measured wind speeds exceeding the thresholds     A 868 MHz radio frequency module is installed in the receiver of model WL 410 and WL 410XB  In  mode WL 410XB  an additional Bluetooth Low Energy chip is installed in the receiver to enable  smartphone communication functionality  WL 410XB sensor output power is st
2.    Working voltage of receiver is 12 to 24 V DC  Please plug the DC power source to the corresponding  jack on the circuit board after opening the front panel        NOTE  Please make sure the polaritv is correct otherwise the receiver will be damaged              Relays  amp  external indicators  The relay jacks are by the side of DC power        Relay 3 When wind speed exceeds the value set on pre alarm 1  the relay 3 will activate  Please see  section    Settings    for more details     Relay 2 When wind speed exceeds the value value set on pre alarm 2  the relay 2 will activate and  yellow light will start blinking and buzzer will sound with interruptions  When sound alarm is  activated you can mute it by pressing upper key for 3 seconds  Please see section    Settings    for more  details     Relay 1 When set value is exceed the relay 1 will activate  red light will flash and buzzer will  continuously sound  When sound alarm is activated you can mute it by pressing upper key for 3  seconds  Please see section    Settings    for more details     Bluetooth  WL 410XB oniv    Wind speed   air temperature data are transmitted over Bluetooth everv second  With free app     Wind Smart    you can read data of current  average and maximum wind speed  temperature or view  historv graphs on vour smartphone     In smartphone Application setting menu alwavs set the address correspond to the address of the  WL 410 XB sensor  The range is up to 40 meters from WL 410 XB displav unit  In
3.  without explicit authorization of  our Technical Dept     The contents of this manual may not be reproduced in any form whatsoever without the  manufacturer s authorization     Our products are patented  The logotypes are registered  We reserve the right to modify  characteristics and prices as part of technological developments which might require them     Services    Shouldn t the instrument work properly  before contacting your distributor make sure that batteries  are correctly installed and working  check the test leads and replace them if necessary     16    Scarlet Tech Co   Ltd      2015 Scarlet Tech Co   Ltd  All rights reserved   4F 3  No  347   HePing E Rd  2nd Sec   DaAn District  Taipei City 106  Taiwan  E mail  info scarlet com tw  http   www scarlet com tw    
4. WARNING  Failure to follow these safety instructions could result in fire  electric shock  or other  injuries  or damage to sound level meter or other property  Read all the safety information below  before using sound level meter     Operate Avoid using instrument in humid or wet places  Make sure that humidity is within the limits  indicated in the next section  Avoid using meter in presence of explosive gas  combustible gas   steam or excessive dust   Be sure to turn it off after use  If you expect not to use the instrument for a  long period remove batteries to avoid leakages of battery liquid which could damage the its inner  components     Handling Handle the meter with care  It is made of sensitive electronic components  The meter can  be damaged if dropped  burned  punctured  or crushed  or if it comes in contact with liquid  Don t  use a damaged meter  such as one with a cracked screen  as it may cause injury     Important handling information    Cleaning Clean instrument immediately if it comes in contact with anything that may cause stains     such as dirt  ink  makeup  or lotions  To clean    e Disconnect all cables and turn instrument off      Usea soft  lint free cloth    e Avoid getting moisture in openings      Don t use cleaning products or compressed air    Operating temperature The instrument is designed to work in ambient temperatures between 5    and 40   C  41   and 104   F  and stored in temperatures between  10   and 60   C  14   and 140   F   The  ins
5. fault Settable range Description   Wind speed 52 km h 1   50 m s Pre alarm 2 limit   On delav YR 0   600 sec Minimum time of exceed wind  speed to activate the pre alarm 2  Delay of alarm switch OFF after   Off delay 0 min 0   60 min wind speed drop below preset  level   Relay Normal Normal interleaved Inverted operation of relay   Pre alarm 1    ET                                  Factorv default Settable range Description   Wind speed 42 km h 1   50 m s Pre alarm 1 limit   On delav desk 0    600 sec Minimum time of exceed wind  speed to activate the pre alarm 1  Delav of alarm switch OFF after   Off delav Omin 0   60 min wind speed drop below preset  level   Relay Normal Normal interleaved Inverted operation of relay          11    General settings             Factorv default    Settable range    Description       Set the sensor address of vour                                  Sensor address Enclosed sensor MD    Wind speed sensor   Averaging period 2 sec 2 10 30 sec ayb DEUED  wind speed   Wind speed unit km h _ i mph  Unit of displaying wind speed   Temperature unit mG    Cor r Unit of displaying Temperature  Wind speed at 20 mA output  4mA   0 km h   20 mA output 180 km h 10   50 m s 20 mA   seted value wind speed    applicable only at model with  additional 4 20 mA output  Activation of password   Password No au protection and setting of   Yes 0000   9999   password   Gan ala On On Off Switching sound alarm ON and  OFF   Language English English French Language selectio
6. lace the sensor battery  Take off the battery cover   on the bottom  by turning it anti clockwise  Pull out the battery holder and insert new battery   Lithium 3 6 V AA      Receiver           Antenna  SMA connector     LCD display Red LED for Max Alarm        Yellow LED for Pre Alarm 2    A Max Alarm indicator  Up Mute button  Down History button    Buzzer Set menu button    ae Pre Alarm 1 indicator    Pre Alarm 2 indicator  Port 1 Portt2 Porta    Signals from sensor  The indication light on the top of the LCD display blinks when the receiver receives signals from the  sensor  every 2 seconds if reception is good   Signal strength is numerically shown in dB     When the sensor stop sending data  in OFF state  or the signal is lost for a more than 30 seconds  the     No data    appears on the display  indicating that the receiver doesn t receive data from the sensor   sensor OFF or out of range      On device alarms    The threshold wind speed of Pre Alarm 1  Pre Alarm 2 and Max Alarm can be configured via setting  menus  Please see the section    Settings    for more details     e Pre Alarm 1 triggers one LED indicator sit beside the LCD screen     2 Pre Alarm 2 triggers two LED indicators sit beside the LCD screen and the yellow LED on the top  of LCD display  It sounds the buzzer interleaved     c Max Alarm triggers all three LED indicators sit beside the LCD screen and the red LED on the top  of LCD display  It sounds the buzzer continuousiv        L 12 to 24 V DC source 
7. n   Wind speed 40 0  Calibration factor for wind speed   calibration factor   15 0    4 15 090 in 0 590 steps   Power ON OFF Bluetooth   Bluetooth On On Off WT            applicable only at WSM  W410XB model          Technical Specification    Instrument    Sensor  amp  receiver    Measurement range   Unit   Resolution   Accuracy   Averaging period  Operating voltage   Power consumption  Transmission distance  Distance with YAGI antenna  Relay contact rating  Temperature operating range  Sensor battery   Sensor battery life   Audible alarm    Antenna input  receiver   Output  Relay    Output    Mechanical   Bearings   Sensor housing   Sensor cups  replaceable   Receiver housing   Sensor dimension  Receiver dimension  Mounting   Bluetooth LE    WL 410  WL 410XB WL 410XB     WL 410 4 20mA 4 20mA    0 6   50 0 m s  m s  km h  knots  mph  0 1 m s     3   Selectable 2s  10 s  30 s  12   24V DC  300 mA  max    300m 1300 m  15 424 km 6 5   10 0 km  1 A 12 V DC  1 A 24V DC   25   60   C  3 6 V AA Lithium batteries  5 years 3 years  85   90 dB    50 ohm  SMA connector    3 xrelays 2A 24V    4   20 mA 4   20 mA  4 mA 0 m s 4 mA 0 m s  20 mA 10   50 m s 20 mA 10   50 m s   programmable   programmable     2 x precision stainless steel ball bearing  AL PVC  PA  Nylon   ABS  IP65  Height 210 mm  cup to cup diameter 120 mm  150x80x55mm  Mounts on a pipe with 4920 mm outside diameter    Yes  Range is up to 30 m     13    Safety  Handling   amp  Maintenance    Important safety information    
8. ng assembly  sensor     Spare parts  Wind cup is replaceable and can be order separately     Standard    EMC This instrument was designed in accordance with EMC Standards in force and its compatibility  has been tested in accordance with EN61326 2  2006      CE Z    Warranty  amp  Services    Warranty conditions   This instrument is guaranteed for one year against material or production defects  in accordance  with our general sales conditions  During the warranty period the manufacturer reserves the right to  decide either to repair or replace the product     Should you need for any reason to return back the instrument for repair or replacement take prior  agreements with the local distributor from whom you bought it  Do not forget to enclose a report  describing the reasons for returning  detected fault   Use only original packaging  Any damage  occurred in transit due to non original packaging will be charged anyhow to the customer     The warranty doesn t apply to    Accessories and batteries  not covered by warranty    Repairs made necessary by improper use  including adaptation to particular applications not  foreseen in the instructions manual  or improper combination with incompatible accessories or  equipment    Repairs made necessary by improper shipping material causing damages in transit    Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized  personnel    Instruments for whatever reason modified by the customer himself
9. ronger   14 dBm   than WL 410  allowing a longer transmission distance     An optional 4 20 mA current loop module is available to both WL 410 and WL 410XB to make long  distance cable transmission possible            Smartphone App    iOS Android Receiver Sensor  f  ET N  resi Bluetooth 868 MHz RF  45 sew   c  c  aj    External  indicators      Control room      P Relays 4 20 mA output    Equipment    Ney ton       p            Sensor  amp  Receiver    Sensor    Wind cup   replaceable     Aluminum  sensor body    Battery cap   O ring sealed     Sensor unit switches ON automatically when the anemometer cups revolve  It switches OFF 6 hours  after the anemometer cups stop revolving  In ON state  the sensor updates wind speed data every  two seconds     Address    The correspondent sensor address has been preset at the factory  Always set the address correspond  to the address of the sensor from which the receiver will receive data  Address of the sensor is  indicated on the sensor label and in the interior of sensor battery compartment     Range   Connection between sensor and receiver goes through free 868 MHz band  optionally 908MHz    Transmission range is up to 500 meters  1300 meters at models XB    at 10 m sensor mounting  height and when there is no obstacle between the sensor and the display unit  Inside buildings the  range is much shorter  Normally the signal can be received through two to three walls     Power    When the    Lo battery    appears on the display  rep
10. side the building the  range is much smaller  Range also varies with tvpe of smartphone or tablet     Android  Applications requires device with Android 4 3 or newer with Bluetooth Low Energy  BLE    Apple  In iPad iPhone settings for application Wind Smart configure parameter  Allow Location  Access  to  While Using the App      Displav    WL 410 XB displav consists of 3 pages including  1  readings of wind speed  2  alarm settings and 3   graphs to provide user information for project management     Bv pressing HIST kev user can navigate to page 2 and 3 to see the wind speed and max  alarm  history  To switch back to the first page user can long pressing HIST key for 3 seconds or leave the  device alone for 1 minutes     First page    Max alarm threshold  Temperature              p alarm 2 threshold    Wind speed unit         km h  26  T3 PH  EW HU Pk    Signal strength       e    df  Peak wind bar graph  Current wind  bar graph    The contents of display are shown above  Note  in both bar graphs  the max alarm value set by user is  always on the 3 4 bar height  One icon not shown in the photo is data packet receiving indicator and  it flashes by the side the signal strength     Current wind speed       Second page       8 hours peak wind speed history graph with 5 minutes resolution  each row presents the peak wind  speed during 5 minutes    Third page    ma       8 hours Maximum alarm historv graph with 5 minutes resolution     Restore receiver to default    With upper bu
11. trument can be damaged and battery life shortened if stored or operated outside of these    temperature ranges  Avoid exposing the instrument to direct sunlight even the the air temperature  is within the limits     Operating humidity The instrument is designed to work in humidity  lt  80 rh and stored in dry  place where humidity is less than 70 rh     Store microphone carefully Microphone is the key component of the instrument and keep it dry  and avoid severe shake or vibration     Batterv replacement Low batterv icon displaved in LCD indicates the user needs to replace batteries  on sensor  To replace     e Unscrewthe O ring sealed battery cap anti clockwise     e Pullout the battery holder  remove old battery and insert new one       Insert the battery cap back and screw the O ring sealed battery cap     NOTE  Please make sure screw the O ring sealed cap correctly to have the best dust and water  proof capability     Packing list   c Wind speed sensor x 1  c Receiver unit x 1   e SMA antenna x 1      User guide x 1    2 Bluetooth  amp  4 20 mA current loop modules are optional in WL 410XB    Accessories  amp  Spare parts  To help in mounting and to enhance the transmission distance  you may need the following  accessories  Please contact your local representative to get the quotation     Accessories   e Magnetic mounting assembly  receiver    c YAGI antenna with 3 m cable   e Outdoor antenna with 3 m cable   c Self leveling mounting assembly  sensor     e Magnetic mounti
12. tton pressed at power ON     RESET is performed  all settings except    Sensor  Address and    WS Cal  Factor    goes to default values      Settings    Setting of parameters    WSM W418 Settings  EES l o auu    Max Alarm    gt Pre Alarm 2  Fre Alarm 1  General    1  Hold pressed SET key to enter the setting menu  If the password protection is active  enter    correct password  The options of settings are shown on display     2  Select the option by using up and down keys and press SET key to enter into selected option     3  By up and down keys select the parameter you wish to adjust and press SET key to enter into    selected parameter  The adjustable parameter blinks     4  By up and down key adjust the parameter value  Press SET to enter new value and move to next    parameter     5  Exiting setting menu  hold pressed SET key to move back for one level  Anemometer also return    to normal operation after 2 minutes of inactivity     Max alarm    Settings  Max Alarm      gt  gt  EE treat FFEFRIR EE     gt WMimnd Speed  79 kmh  OH Delau B s  Delau B min    Relay  Normal  Factory default Settable range  Wind speed 72 km h 1   50 m s  On delay O sec 0   600 sec  Off delay 0 min 0   60 min  Relay Normal Normal interleaved    Description  Max alarm limit    Minimum time of exceed wind  speed to activate the max alarm    Delay of alarm switch OFF after  wind speed drop below preset  level    Inverted operation of relav    Pre alarm 2                                     Factorv de
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
AUR450C User's Manual  ParkZone UM F-27Q Stryker 180 BNF  hp StorageWorks edge switch 2/12 service manual  Téléchargement - NEC Display Solutions Europe  Nokia Lumia 920 32GB 4G White  Sélection librairie_pour pdf  DISK INTERFACE Manual Supplement for version 4 of TR-DOS  1.- Tengo un usuario de convocatorias anteriores, ¿Puedo  3G WI-FI HOTSPOT  IFS NS3550-8T-2S Quick Installation Guide    Copyright © All rights reserved. 