Home

V600 Series Hand-held Reader Writer User's Manual

image

Contents

1. 8 Click the Browse Button and select the folder in which the downloaded file V600_CHUD_200 inf is saved Then click the Next Button e 2 Found New Hardware V600 CHUD Browse for driver software on your computer Search for driver software in this location Browse Include subfolders Next Cancel RFID System User s Manual suonesedaig suoneorunuiuio GNHD 009A 33 V600 CHUD Communications Preparations 34 Section 2 Communications Preparations wv 9 When the following window is displayed select Install this driver software anyway Button ta Windows Security es amp Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information v See details When the following window is displayed installation is completed e U Found New Hardware OMRON RFID USB COM COM3 The software for this device has been successfully installed Windows has finished installing the driver software for this device OMRON RFID USB COM wv 10 Click the Close Button t The displays that actually appear depend on your computer environment e z
2. lt j Controller Control Commands 96 44 Other Commands 100 4 End code List 101 RFID System User s Manual 45 x m gt o a o E Ee o c B Ez G 9 c 2 E E o o Section 3 Commands Communications with the Data Carrier There are 4 types of commands for communicating with the Data Carrier using the Hand held Reader Writer Normal commands Button commands Auto commands Button auto commands Normal Commands Normal commands are sent from the host device for communications with the Data Carrier after the antenna end of the Hand held Reader Writer has been moved close to the Data Carrier 1 Move the antenna end of the Hand held Reader Writer close to the Data Carrier S a er i Ma Host device Data Carrier Hand held Reader Writer Communications with Data Carrier Command e Response 2 Commands are sent from the host device to the Hand held Reader Writer 3 The Hand held Reader Writer communicates with the Data Carrier 4 A response is returned from the Hand held Reader Writer to the host device If communications are normal the operation indicator LED lights green and then turns OFF If the Data Carrier is not detected within the Hand held Reader Writer s communication area when the command is sent from the host device a Data Carrier Non existent Error will occur At this time the operation indicator will flash red R
3. Processing Command pata Humber Read area Number of code setting setting start address read bytes Terminator 2 1 1 4 4 2 Data setting Sets the code format used to send responses for read data A ASCII The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters m H Hexadecimal code Processing area number Always 1 setting o Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal B code 5 Setting range 0000h to 1FFFh Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal o 3 E E o o Response Command code End code Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UR p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual Section 3 Commands EXPANSION BATCH BUTTON AUTO WRITE uw After this command is received by the Hand held Reader Writer up to 2 Kbytes of data will be written to the Data Carrier in a batch when th
4. Section 2 Communications Preparations T Click the Next Button Found New Hardware Wizard Driver Files Search Results The wizard has finished searching for driver files for your hardware device ey The wizard found a driver for the following device oy VEDD CHUD Windows found a driver for this device To install the driver Windows found click Next J c Molder nemefid win2kcom inf The following window will be displayed when software installation is completed Found New Hardware Wizard Completing the Found New Hardware Wizard gt OMRON RFID USB COM Windows has finished installing the software for this device To close this wizard click Finish wv 8 Click the Finish Button RFID System User s Manual suonesedaig suoneorunuiuo GNHD 009A 25 V600 CHUD Communications Preparations Checking Installation Check that the driver is correctly installed 1 Connect the Hand held Reader Writer to the personal computer wv 2 On the Start Menu select Settings Control Panel System wv 3 Select the Device Manager Button on the Hardware Tab Page System Properties RFID System User s Manual 4 Select Ports COM amp LPT and check that OMRON RFID USB COM is displayed The driver is correctly installed if this port is displayed Device Manager FAIS TOSHIBA EN 2 DVD CD ROM drives Floppy disk controllers amp Floppy disk d
5. 4 Doo poof J Y v Vinyl insulated round cable 3 5 mm dia Standard length 1 9 m Unit mm o c 2 V600 CH1D V2 E l 45 E E T t 28 4 cp E 255 e i S 5 11 i o m 65 49 J o o a o I 160 5 gt je 2500 gt ja 44 9 24 99 N Y 33 mo ae l I s 32 2 oohononnonn AL t C I Vinyl insulated round cable 3 5 mm dia ER k Standard length 2 5 m i 190 10 5 ae tH Unit mm I 34 5 RFID System 1 24 User s Manual Section 6 Appendices V600 CH1D PSI l 45 4 c C H ia S n Dp E 25 i n Ie 65 lx 49 160 5 gt j 2500 44 9 gt 24 99 N y 33 eer F TTL s t Vinyl insulated round cable 3 5 mm dia C Ee Standard length 2 5 m V600 A22 25 41 54 1 48 1 Mm 4 0 1 dia Unit mm Unit mm RFID System User s Manual suoisueuiig pue suonesyoads 125 o c 2 7 c o E a Uv c o c o 2 f E o o 2 o 126 Section 6 Appendices Transmission Specifications Transmission with the currently
6. Batteries Computer w Disk drives E Display adapters gt 2 DVD CD ROM drives 3 Floppy disk controllers ld Floppy disk drives gig Human Interface Devices IDE ATAJATAPI controllers gaj Infrared devices 5 gt Keyboards EB o Mice and other pointing devices amp Modems E E9 Network adapters B PCMCIA adapters JJ Ports COM amp LPT X Communications Port COMI J ECP Printer Port LP Sound video and game controllers System devices Universal Serial Bus controllers z Communications with the Hand held Reader Writer can be performed with the COM number displayed in parentheses after OMRON RFID USB COM RFID System User s Manual suonesedaig suoneorunuiuo ANHI 009A 31 V600 CHUD Communications Preparations Section 2 Communications Preparations Windows Vista 1 Turn ON the power to the personal computer and start Windows Vista wv 2 Connect the Hand held Reader Writer to the computer via USB v For details on connection methods refer to V600 CHUD Communications Preparations e CHECK A p 22 z Wait for the following window to be displayed v 3 When the following window is displayed select Locate and install driver software recommended Button Found New Hardware fs Windows needs to install driver software for your V600 CHUD Locate and install driver software recommended Windows will guide
7. E2 CHECK RFID System User s Manual Section 2 Communications Preparations Checking Installation Check that the driver is correctly installed 1 Connect the Hand held Reader Writer to the personal computer wv 2 On the Start Menu select Control Panel Performance and Maintenance v 3 Click the System Icon wv 4 Click the Device Manager Button vyv 5 Select Ports COM amp LPT and check that OMRON RFID USB COM is displayed The driver is correctly installed if this port is displayed Device Manager Le Een fee File Action View Help amp emis Computer Hyg Disk drives My Display adapters tei DVD CD ROM drives Floppy disk drives 49 Floppy drive controllers os Human Interface Devices E cg IDE ATA ATAPI controllers Keyboards n Mice and other pointing devices amp Monitors gt Other devices Ports COM amp LPT 19 Communications Port COMI 777 Communications Port COM2 YP ECP Printer Port LPTL x J Processors lt gt Storage controllers aa System devices Q Universal Serial Bus controllers m Communications with the Hand held Reader Writer can be performed with the COM number displayed in parentheses after OMRON RFID USB COM RFID System User s Manual suonesedaig suoneorunuiuo qnHa2 009A 35 V600 CH1D V2 Communications Preparation Section 2 Communications Preparations V600 CH1D V2 Communications P
8. Note Items marked by an asterisk are set as the default when shipped from the factory Basic Function Settings The Auto Command OFF and Normal Operation Output functions can be set Use the BASIC FUNC TIONS SETTING FN command Item Contents Auto Command OFF Yes 1 minute No function Normal Operation No Yes Output function Note Items marked by an asterisk are set as the default when shipped from the factory e Reading the Settings Use the SET INFORMATION READ UL command to read the settings of the Hand held Reader Writer The information read by the SET INFORMATION READ command is set in the backup memory of the Hand held Reader Writer For this reason care must be taken when the power is first turned ON after the settings have been changed because the operational settings of the Hand held Reader Writer will be different Initializing the Settings A setting command is used to set the Hand held Reader Writer but if the communications parameters are not known or if the setting contents are damaged it is possible that communications will no longer be possible with the host device If this occurs press both the reset button and the activate switch when turning ON the power This will return all settings to the defaults set when the Hand held Reader Writer was shipped from the factory allowing communications with the host device again RFID System User s Manual Section 2 Communications Pre
9. and Limitations of Liability CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the product may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission This document is protected by copyright and is intended solely for use in conjunction with the product Please notify us before copying or reproducing this document in any manner for any other purpose If copying or transmitting
10. ing as follows Frame Division Method Divide the data into frames each with 266 characters max 2 Use the final terminator CR for the last frame frame n only Use the delimiter CR at the end of other frames 3 Be sure to include the command code data setting processing area number setting and start address in the first frame frame 1 If any of these parameters is omitted a command input error will occur The write data can be omitted 4 Make sure that data is divided correctly without any single frames containing AA CR or XZ CR 4 266 characters max per frame 2 o 7 zt El o i Oo Frame 1 3 3 Frame 2 Write data 2 CRI c i i i o A 2 Frame n 1 Write data n 1 o 3 Frame n Write data n CR o Oo o 3 Communications Procedure 3 Command 1 Command 2 Command n 1 Command n a Host pema 2 Hand held Reader Writer Delimiter Delimiter Delimiter Delimiter Response RFID System User s Manual 7 Section 3 Commands EXPANSION BATCH READ rd This command reads up to 2 Kbytes of data from the Data Carrier in a batch If the Data Carrier is not in communications range an error response end code 72 Data Carrier non existent will be returned Processing Command Data number Read area Number of code Setting setting start address read bytes Terminator 2 1 1 4 4 2 Data setting Sets the code format used to send response
11. 00 indicates normal completion For details on end codes refer to End code List UA p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual Section 3 Commands When the read data is 251 characters or higher The data received from the host device is divided into frames according to the delimiters CR as shown in the following diagram i 256 characters max per frame e 250 characters _________ Frame 1 NR 00 Read data 1 E 954 characters X Frame 2 Read data 2 dias 1 Read data n 1 n E 254 characters max gt Frame n Read data n gt x CRI Communications Procedure Command Delimiter Delimiter Delimiter Delimiter Host pees ee a ee Hand held Reader Writer Response 1 Response 2 Response n 1 Response n spueuiuo suonesiunwwog 3IIT SETS RFID System User s Manual TT Section 3 Commands EXPANSION DIVIDED AUTO WRITE NW This command divides and writes up to 2 Kbytes of data to the Data Carrier when the Hand held Reader Writer is moved close to the Data Carrier The Hand held Reader Writer responds when com munications between the Hand held Reader Writer and Data Carrier have ended The host device ca
12. 0036H 002FH 0030H 0031H 0032H 0033H 0034H 0035H 0036H Before Writing 2 E 3 0 3 1 3 2 3 3 3 4 3 5 3 6 After Writing Section 3 Commands EXPANSION BATCH FILL fl This command writes specified data for the number of write bytes starting from the specified write start address Up to 2 Kbytes of data can be written in a batch Processing Command pais number Write area Number of Specified code setting setting start address write bytes data Terminator Data setting Always H Processing area number Always 1 setting Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of write bytes Specifies the data to be written to the Data Carrier in 4 digit hexadecimal Setting range 0001h to 0800h Specified data Indicates the data to be written to the Data Carrier Response Command code Endcode Terminator spuewwoy suoneoiunuluo2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List il 2 p 101 RFID System User s Manual 91 Section 3 Commands DATA CHECK MDC K This command writes or compares the CRC code using the specified check block unit The CRC code is calculated from the generated polynomial expression
13. 5 2 25 2 1000 5 FE0 BS CAN ETE NE SUE NN 1001 9 FE HT EM yl lilylily 1010 10 FE2 LF SUB Aaa ee 1011 11 FEXVT ESC JE LCS US ES 1100 12 FE FF IS4FS RUPEE UE EUN 1101 13 FEs CR ISs GS 2 M 1 m 2 1110 14 SO IS2 RS gt UNE ede eins 1111 15 ISI IS US lol o DEL Note Do not use the undefined areas RFID System User s Manual Degree of Protection International protection degrees IP Section 6 Appendices are determined by the following tests Be sure to check the sealing capability under the actual operating environment and conditions before actual use elEC International Electrotechnical Commission Standards IEC60529 November 2001 IP ii B A Degree of Protection from Solid Materials Degree Protection 0 reg No protection 50 mm dia Protects against penetration of any solid object such as a hand that is 50 mm or more in diameter 1 e je e 125 mm ai Protects against penetration of any solid object such as a finger that is 12 5 mm or more in diame 2 e lo ter e 25mm Pretects against penetration of any solid object such as a wire that is 2 5 mm or more in e RE 3 Ws diameter Aii Protects against penetration of any solid object such as a wire that is 1 mm or more in diameter 4 EXT l Protects against penetration of dust of a quantity that may cause malfunction or obstruct the safe 5 operation of the pr
14. Click the Browse Button and select the folder in which the downloaded file RFID Win2kcom inf is saved Then click the Next Button Found New Hardware Wizard Please choose your search and installation options ee Y Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM Include this location in the search C Molder_name Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware ge Tne J Cancel ww 5 Click the Continue Anyway Button Hardware Installation T N The software you are installing for this hardware e OMRON RFID USB COM has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing suonesedaig suoneorunuiuo GNHD 009A Continue Anyway 1 When the following window is display
15. Hand held Reader Writer Is the operation indicator NO lit green 9 ueu2Mo J Bunoousoe qnoJj RFID System Users Manual 119 Troubleshooting Flowchart 120 MEMO RFID System User s Manual Section 6 Appendices 4X Specifications and Dimensions 122 d Data Carrier Memory Map 134 d Data Carrier Memory Capacity and Data Type V600 Series 135 4 List of ASCII Characters 136 44 Degree of Protection 137 RFID System Users Manual 121 Section 6 Appendices Specifications and Dimensions o c 2 7 c o E a Uv c o c o 2 f E o o 2 o 122 General Specifications Item Specification V600 CHUD V600 CH1D V2 V600 CH1D PSI Supply voltage 5 0 VDC 5 Ambient operating temperature 10 to 55 C Ambient operating humidity 35 to 85 with no condensation Ambient storage temperature 25 to 65 C Ambient storage humidity 35 to 85 with no condensation Degree of protection IEC60529 IP63 See note Weight Approx 120 g with cables and Approx 160 g with cables and Approx 110 g with cables and connectors connectors connectors Current consumption 250 mA max supply voltage 5 0 V Material Case ABS resin Nameplate PET resin Vibration resistance 10 to 150 Hz 0 2 mm double amplitude at 15 m s acceleration in 6 directions 10 times fo
16. Message data Terminator EDEN i i i i x i spueulUJO2 1SO0H End code Indicates the execution result for the command 00 Normal completion For details on end codes refer to End code List p 101 VERSION READ VS Reads the Hand held Reader Writer s model information software version and software creation date Command code Terminator Response Command code End code Terminator End code Indicates the execution result for the command 00 Normal completion For details on end codes refer to End code List p 101 RFID System User s Manual 95 Section 3 Commands Controller Control Commands These commands are used to reset the Controller or set serial communications ABORT XZ This command is used to restore the Hand held Reader Writer to command wait status when there is no response from the Hand held Reader Writer due to some problem during communications with the host device or with a Data Carrier V The ABORT XZ command can be used only with the V600 CH1D V2 T Do not use it with the V600 CHUD lt J CHECK Command code Terminator CR x N N Response None c G E E o o o 5 o o b 2 5 o o RFID System User s Manual Section 3 Commands COMMUNICATIONS CONDITIONS SETTING TR This command is used to set serial communications parameters The Hand held Reader Writer must be restarted to make the changes take effe
17. V600 CH1D PSI A built in RS 232C serial interface in the V600 CH1D PSI Hand held Reader Writer allows communications with personal computers and programmable controllers that are equipped with an RS 232C interface Host Devices Work About Pro manufactured by Zebra Technologies Inc Hand held Reader Writer V600 CH1D PSI Data Carriers The V600 CH1D PSI Hand held Reader Writer can be used with any Data Carrier in the V600 Series st For details on Hand held Reader Writer and Data Carrier models refer to Section 6 Appendices be mess zi p 122 p 135 RFID System User s Manual Section 1 Product Overview Operation Flowchart V600 CHUD Connect the V600 CHUD to the host device When connecting for the first time the USB driver must be installed c 2 90 2 2 g p 22 p 23 v 1eu2 0 4 uonejedo Perform the communications test between the host device and Hand held Reader Writer f 2 p 43 Perform the communications test between the Data Carrier and Hand held Reader Writer Test LU p 43 Check the ambient environment p 122 Operate the system using real commands p 45 JU is 9 o E D E RFID System User s Manual 17 c c c o z o i c 9 p c pU o 2 o 18 Section 1 Product Overview V600 CH1D V2 c 2 g 19 2 e Oo Communications preparation Test
18. X16 X12 X5 1 Processing Command process number Check block Number of check code setting setting start address block bytes Terminator pmo fom sfx xx xfay e or 2 1 1 4 2 2 Process setting Specifies the check process K Check code calculation C Check code comparison Processing area number Always 1 setting Check block start Specifies the start address of the check block in 4 digit hexadecimal address Setting range 0000h to 1FFDh Number of check block Specifies the number of bytes in the check block in 2 digit hexadecimal bytes Setting range 00h 03h to FFh 00 256 bytes The number of check block bytes is the check code calculation area 2 bytes For details refer to Memory Check Function in Data Carrier v zW p 114 o o c E E o o o c 2 pz G 2 c 3 E E o o Response Command code End code Terminator 2 2 2 End code Indicates the execution result for the command 00 Normal completion 76 Data error warning only during comparison control For details on end codes refer to End code List UR p 101 vu For details on the memory check refer to Memory Check Function in Data Carrier Q Ne CHECK ICA p 114 RFID System User s Manual Section 3 Commands OVERWRITE COUNT CONTROL MDS This command is used to control the number of overwrite operations performed by EEPROM Data Car riers This command determines whether
19. bytes as follows Area 1 bytes Area N bytes lt 256 bytes RFID System User s Manual Section 3 Commands Response Processing Area Number 1 Command code End code Read data Terminator penus 2 2 n 2 Processing Area Number 2 Command Read data Read data code End code area 1 area 2 Terminator Area 1 setting Area 2 setting End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List il p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 SspueulUulo2 suoneoiunuluo2 RFID System User s Manual 63 Section 3 Commands BUTTON WRITE BW After this command is received by the Hand held Reader Writer data is written to the Data Carrier by pressing the activate switch If the activate switch is pressed and the Data Carrier is not in communica tions range an error response end code 72 Data Carrier non existent will be returned Processing Area Number 1 Processing area Command Data number Write area code setting setting start address Write data Terminator 2 1 1 4 n 2 Processing Area Number 2 Processing 5 Command Data area number Write area Number of Data Write area Number of code setting setting start address
20. can read and write across several non consecutive Data Carrier memory areas 10 areas max at one time To use this feature the number of control areas is specified using the NUMBER OF CONTROL AREAS command ASCII and hexadecimal code can be used simultaneously for the one command control but reading and writing cannot be performed 104 simultaneously opi CHECK A p 59 RFID System User s Manual Example Data in the Following 3 Areas are Read _ 0010H 4 F OQ Area 1 Address 0010H oor 4 D Mi Number of bytes 05 bytes eee 0012H i s ii H pss Code setting ASCII abi i 0014H 4 E N Area 2 Address 0030H Number of bytes 02 bytes o u 5 Code setting Hexadecimal eG 0030H 1 2 5 rea o Area 3 Address 0035H WOOTH 3 4 iL Number of bytes 03 bytes 2 Code setting Hexadecimal x 0035H 3 1 z 5 Area 3 0036H 3 2 E 0037H 3 3 o t kej 2 E Command RDA3001005H003002H003503 CR Response RD00OMRON1234313233 CR l l Jl l l Area 1 Area 2 Area 3 Vw Refer to Command and Response Format for more details on ASCII and hexadecimal codes Section 4 Functions Auto Command OFF Function If communications with the Data Carrier do not begin within one minute after an auto command or button auto command is sent from the host device to the Hand held Reader Writer after entering the Data Carrier wait status the Auto Command OFF function automatically aborts the
21. command Data Contains the details of the command and response as follows ASCII hexadecimal code specification processing specification mode specification Processing area number specification Processing start address Number of bytes to be read write data Terminator Indicates end of command response Specifying Data Code Whether the read or write data is treated as an ASCII or JIS 8 code or hexadecimal code is specified in a command G E pe o LL o o c o o o o tc o c o c E E o o ASCIl JIS 8 Code One character of ASCII or JIS 8 code data occupies 1 byte 1 address of the Data Carrier memory Example of Specifying ASCII Code eData Carrier w T A 1 0 o 1 0 O M R O N CR Address l 1 m Leal L 1 I 0010 a Command code ASCII Processing Start address Write data Terminator T setting eri number 0011 M 0012 B 0013 sO 0014 N RFID System User s Manual Section 3 Commands eHexadecimal Code One character is treated as a hexadecimal number Therefore only numerals 0 through 9 and A to F can be accepted Two characters of data occupy 1 byte 1 address of the Data Carrier memory Therefore specify data in 2 character units in even numbers when using a WRITE command If an odd number of charac ters is specified by mistake an error will occur Example of Specifying Hexadecimal Code w F H 1 o o 1 o 1 9 9 6 CR H
22. note 2 Vertical parity error 11 See note 2 Framing error 12 See note 2 Overrun error 14 Format error 15 Execution status error 18 Frame length error Lower communications error 70 Data Carrier communications error 71 Mismatch error 72 Data Carrier non existent error 76 Data error 7A Address error 7C Antenna error 7D Write protect error Memory error 93 See note 2 EEPROM memory error Note 1 A 7B error code response indicates that the command was completed normally but the battery voltage is low If the battery voltage is so low that a response cannot be returned an error code such as 72 will be returned 2 Vertical parity errors framing errors and overrun errors do not occur for the V600 CHUD For details on each error refer to Error Tables O hes CHECK C p 118 RFID System User s Manual 1sr 9poo pu3 101 2 d o o o xo c ul 102 MEMO RFID System User s Manual Section 4 Functions 44 Hand held Reader Writer 104 Multiple Area Control 104 Auto Command OFF Function 105 Normal Operation Output Function 105 Data Carrier 106 Manufacturing Date Format Default Setting 106 Write Protect Function 107 Data Carrier Service Life Detection 111 Memory Check Function in Data Carrier 114 RFID System User s Manual 103 Section 4 Functions Hand held Reader Writer Functions Multiple Area Control The Hand held Reader Writer
23. specification Terminator p Auto Command OFF Designates whether the Auto Command OFF function is used specifications 0 Auto Command OFF used 1 Auto Command OFF not used Default setting Auto Command OFF used Normal Operation Out Designates whether the Normal Operation Output is used put Specification 0 Normal Operation Output used 1 Normal Operation Output not used Default setting Normal Operation Output used Response Command code End code Terminator 2 2 2 End code Indicates the execution result for the command 00 Normal completion For details on end codes refer to End code List il A p 101 RFID System User s Manual Section 3 Commands SET INFORMATION READ UL This command is used to read the settings of the Hand held Reader Writer S Only the Auto Command OFF function is supported by the V600 CHUD The settings made with the COMMUNICATIONS CONDITIONS SETTING TR command are not valid for the V600 CHUD CHECK Command code Terminator Response Command Settings for code End code Settings for TR command FN command Data Stop Normal length bits Operation Baud Parity Auto Command Output rate OFF specification specification Hand held Reader Writer system data Terminator S l 0 0 0 0 0 0 CR 8 2 End code Indicates the execution result for the command 00 Normal completion For details on end codes refer to End code L
24. the Data Carrier when the antenna is moved near the front of the Data Carrier after a command is sent from the host device Host device Data Carrier Hand held Reader Writer Communications with Data Carrier Command Response 1 A command is sent from the host device to the Hand held Reader Writer 2 The Hand held Reader Writer enters the communication stand by state with the Data Carrier and the operation indicator LED flashes green Nu If the Data Carrier is not detected within one minute of sending the command a timeout will occur and a Data Carrier E A Non existent Error will occur As a result the operation indicator will flash red CHECK 3 Communications with the Data Carrier are performed when the antenna end of the Hand held Reader Writer is moved near the Data Carrier 4 A response is returned from the Hand held Reader Writer to the host device If communications end normally the operation indicator LED lights green and then turns OFF RFID System User s Manual Section 3 Commands Button Auto Commands Button auto commands execute auto commands after a command is sent from the host device and the activate Switch of the Hand held Reader Writer is pressed Host device Data Carrier Hand held Reader Writer Press Communications with Data Carrier Command Response 1 A command is sent from the host device to the Han
25. the operation indicator is lit or flashing for a certain time it will turn OFF CHECK eActivate Switch When button commands button commands button auto commands are used and the activate switch is pressed communications with the Data Carrier will commence For details on button commands refer to Section 3 Commands When the activate switch is pressed with the Hand held Reader Writer in the initialization stand by mode with the green LED flashing the function settings will be initialized eReset Button Press this button for two seconds or more when the power is first turned ON to put the Hand held Reader Writer into the initialization stand by mode eAC Adaptor Connection Jack This is a connection jack for the V600 A22 AC eSerial Interface Connector This is a serial interface with an RS 232C compliant D Sub 9 pin connec tor eAntenna To communicate with the Data Carrier move the antenna head closer to it V600 CH1D PSI Antenna NN Operation indicator LED Activate switch O Lj gt SSS I lt Reset button Serial interface connector Section 1 Product Overview Operation Indicator LED Display Meaning A command has been received from the host device C Communications with the Data Carrier have completed normally Lit green e When the power is turned ON after initialization of the Hand held Reader Writer
26. to End code List il A p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 spuewwon suoneoiunuluo2 RFID System User s Manual 67 Section 3 Commands BUTTON AUTO WRITE UW After this command is received by the Hand held Reader Writer data will be written to the Data Carrier after the activate switch is pressed and the Hand held Reader Writer is close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Area Number 1 Processing area A Command Data number Write area code setting setting start address Write data Terminator 2 1 1 4 n 2 Processing Area Number 2 H Hexadecimal code When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame o Processing xe Command Data Ambe Write area Number of Data Write area Number of S code setting setting start address write bytes Write data setting start address write bytes Write data Terminator E E o o o c Area 1 settin Area 2 setting o g 5 Data setting Sets the code format used to send responses for read data A ASCII 23 E E o o Processing area number Specifies the processing area number setting Set
27. water jet Protects against water jet Water is jet sprayed at any 2 5 to 3 m 12 5 min 9to om spray spray approaching at any angle towards the product m angle towards the product for 1 min per square meter ae for at least 3 min in total if from the test machine Discharging nozzle 6 3 dia 6 Protection against high Protects against high pres Water is jet sprayed at any 2 5 to 3 m 100 min pressure water jet spray sure water jet spray approach ing at any angle towards the product angle towards the product for 1 min per square meter for at least 3 min in total from the test machine gs Discharging nozzle 12 5 dia Ec underwater 7 Protection underwater Resists the penetration of The product is placed 1 m water when the product is deep in water if the prod placed underwater at speci uct is 850 mm max in fied pressure for a specified height for 30 min time 8 Protection underwater Can be used continuously The test method is deter See note mined by the manufac turer and user Note OMRON Test Method c Usage condition 10 m or less under water in natural conditions 2 1 No water ingress after 1 hour under water at 2 atmospheres of pressure 2 2 Sensing distance and insulation resistance specifications must be met after 100 repetitions of half hour in 5 C water and half hour in 85 C water im About IPX9K o IPX9K is a protection standard regarding hi
28. 00 D23P72 Data retention 10 years V600 D23P66N V600 D23P66SP V600 D8KF04 8 Kbytes Fe RAM Overwrite operations 1 000 000 000 times Data retention 10 years seus 009A ed e1eg pue Ajoede Aiowap 11e eead Z WARNING The SRAM Data Carrier has a built in lithium battery that can ignite combust or explode if mishandled which may occasionally result in serious injury Do not disassemble pressurize or deform the Data Carrier subject it to high temperatures of 100 C or more or dispose of it fr by incineration Dispose of the Data Carrier as industrial waste RFID System User s Manual 135 o x o o x X o o 2 lt 4 o 2 136 Section 6 Appendices List of ASCII Characters Left digit b8 to b5 0000 1001 0010 0011 0100 0101 0110 0111 1000 1101 1010 1011 1100 1101 1110 1111 Right digit Col b4 to b1 umn 0 1 Peal esr Ae Lm Ge er a eee MESE TES To S Ade LR Porn ral n Row 0000 0 NUL TC7 DLE SP 0 P p 0001 1 TC SOH DC aaa EE 0010 2 TCXSTX DCe a ee ES OBS ae e 0011 3 TC ETX DCs IP SEE Tels 0100 4 TC EOT DCa 4 np rTila t 0101 5 TCs NEQ TC NAK 5 E U e u E E E E 2 E 2 E 0110 6 TC ACK TCE SY amp 6 F v f v 8 8S 9 9 99 95 E pond E E c c 0111 7 BEL TO ET z wlglw 2 2525 5
29. 2 1 1 4 n 2 Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code Processing area number Always 1 setting Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh Write data Indicates the data to be written to the Data Carrier The maximum number of bytes that can be written at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters Response Command code Endcode Terminator eium 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UR p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 83 Section 3 Commands EXPANSION BATCH BUTTON READ br After this command is received by the Hand held Reader Writer up to 2 Kbytes of data will be read from the Data Carrier in a batch when the activate switch is pressed If the activate switch is pressed and the Data Carrier is not in communications range an error response end code 72 Data Carrier non existent will be returned Processing Command pata namber Read area Number of code _ setting setting start address read bytes Terminator 2 1 1 4 4 2 Data setting Sets the code format used t
30. 48 Number of processing data bytes ransmission Time 8000 7000 6000 Write 5000 pm 4000 E 3000 E 2000 1000 0 Transmission time ms 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 1 5N 61 0 Write T 3 5N 75 1 N Number of processing o c S 7 c o E a Uv c 0 c o 2 E o o 2 o Note The number of TAT data bytes represents the number of bytes when ASCII code is specified RFID System 130 User s Manual Section 6 Appendices V600 CH1D V2 SRAM Data Carrier Reference TAT 8000 7000 6000 5000 4000 1 3000 2000 Read 1000 Write Transmission time ms 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes eTransmission Time 8000 7000 6000 Write 5000 4000 DS Read 3000 T 2000 1000 Transmission time ms 0 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 1 5N 37 0 Write T 3 5N 51 3 N Number of processing suoisueuiig pue suoneoyioeds RFID System Users Manual 131 Section 6 Appendices eEEPROM Data Carrier Refe
31. ABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end produ
32. E AW This command writes data to the Data Carrier when the Data Carrier enters the communications area The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Area Number 1 Processing area g Command Data number Write area code setting Setting start address Write data Terminator 2 1 1 4 n 2 Processing Area Number 2 Processing Command pata number Write area Number of Data Write area Number of code setting setting start address write bytes Write data setting start address write bytes Write data Terminator Area 1 setting Area 2 setting Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code o o c E E o o o c 2 pz G 2 c 3 E E o o When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of write bytes When multiple processing areas are used specifies the number
33. FID System User s Manual Section 3 Commands Button Commands Button commands used to perform communications with the Data Carrier are activated when the acti vate switch is pressed after commands are sent from the host device and the antenna end of the Hand held Reader Writer has been moved close to the Data Carrier Host device Data Carrier Hand held Reader Writer Communications with Data Carrier Command Response 1 A command is sent from the host device to the Hand held Reader Writer As a result the operation indicator will light green 2 Move the antenna end of the Hand held Reader Writer close to the Data Carrier Jo1Je2 ejeq eui YUM suoneoiunuiuoo XEITETRETS 3 Press the Hand held Reader Writer activate switch 4 The Hand held Reader Writer communicates with the Data Carrier 5 A response is returned to the host device from the Hand held Reader Writer If communications are normal the operation indicator LED lights green and then turns OFF If the Data Carrier is not detected within the Hand held Reader Writer s communication area when the activate switch is pressed a Data Carrier Non existent Error will occur At this time the operation indicator will flash red RFID System User s Manual 4 x m gt o a o E Ee o c B Ez G 9 c 2 E E o o 48 Section 3 Commands Auto Commands Auto commands can execute communications with
34. Fh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of read bytes When multiple processing areas are used specifies the number of bytes to be read from the Data Carrier in 2 digit hexadecimal code The maximum number of bytes that can be read at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 00h to FFh 00 256 bytes When multiple processing areas are used set so that the total number of bytes to be read for all areas is within 256 bytes as follows Area 1 bytes Area N bytes lt 256 bytes RFID System User s Manual Section 3 Commands Response Processing Area Number 1 Command code End code Read data Terminator Inns 2 2 n 2 Processing Area Number 2 Command Read data Read data code End code area 1 area 2 Terminator Area 1 setting Area 2 setting End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List il A p 101 Read data Specifies the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 spuewwon suoneoiunuluo2 RFID System User s Manual 59 Section 3 Commands AUTO WRIT
35. H Address Bit Upper digit Lower digit 1 0 0 0 0 0 0 0 0002 8 0 0 0 0 0 0 1 1 0 0003 0 6 0 0 0 0 0 1 1 1 0004 0 7 1 1 1 1 1 1 1 1 0005 F F Address Bit Upper digit Lower digit 0 0 0 0 0 0 0 0 0002 0 0 0 0 0 0 0 1 1 0 0003 0 6 0 0 0 0 0 1 1 1 0004 0 7 1 1 1 1 1 1 1 1 0005 F F RFID System User s Manual Section 4 Functions AN WARNING The SRAM Data Carrier has a built in lithium battery that can ignite combust or explode if mishandled which may occasionally result in serious injury Do not disassemble pressurize 2 or deform the Data Carrier subject it to high temperatures of 100 C or more or dispose of it by incineration Dispose of the Data Carrier as industrial waste Jane ejeg RFID System Users Manual 109 Section 4 Functions Write Protect Setting Examples 2 Kbyte Memory Data Carrier 1 Settings to Write protect Addresses 0015H to 0120H Start address End address Address Address Bt 7 6 5 4 3 2 1 0 0000 1 0 0 0 0 0 0 0 0002 Hexa E Write protected 8 0 deci 0120 area mal 0 o0 0 1 0 1 0 1 0003 1 5 07FF 0 0 0 0 0 0 0 1 0004 0 1 0 0 1 0 0 0 0 0 0005 2 0 2 Settings to Write protect 1 Byte 1 byte Write protected area o Start address End address 2 i 5 Specify
36. II H Hexadecimal code When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame o o c E E o o o c 2 pz G 2 c 3 E E o o Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of write bytes When multiple processing areas are used specifies the number of bytes to be written to the Data Carrier in 2 digit hexadecimal code The maximum number of bytes that can be written at one time is 256 bytes as follows e ASCII 256 bytes 256 characters e Hexadecimal code 256 bytes 512 characters Setting range 01h to FFh When multiple processing areas are used set so that the total number of bytes to be written for all areas is within 256 bytes as follows Area 1 bytes Area N bytes lt 256 bytes Write data Specifies the write data from the Data Carrier The characters in ASCII indicate the number of write bytes and the characters in hexadecimal code indicate the number of write bytes x 2 RFID System User s Manual Response Command code E
37. ITE ur EXPANSION Reads up to 2 Kbytes of data from the Data Carrier in a batch when the BATCH BUTTON Data Carrier enters the communications area after the activate switch p 86 AUTO READ is pressed RFID System User s Manual Section 3 Commands Command code Command name Function Page uw EXPANSION Writes up to 2 Kbytes of data to the Data Carrier in a batch when the BATCH BUTTON Data Carrier enters the communications area after the activate switch p 87 AUTO WRITE is pressed CW CALCULATION Writes the calculation results for the memory data to the Data Carrier p 88 WRITE FL FILL Writes data for the specified number of write bytes beginning from the 89 write start address specified in the command P fl EXPANSION Writes data for the specified number of write bytes beginning from the BATCH write start address specified in the command Up to 2 Kbytes of data p 91 FILL can be written in a batch MDC K DATA CHECK Calculates or compares memory check codes in the Data Carrier p 92 MDS OVERWRITE Controls the number of overwrites for EEPROM Data Carriers 93 COUNT CONTROL M Communications Subcommands These commands are used to cancel command execution Command code Command name Function Page AA COMMAND PRO Forcedly ends communications with the Data Carrier CESSING TERMI p 94 NATE eHost Commands These commands are used to test communications between the Hand held Reader W
38. O 10 20 30 do X V600 D23P71 V600 D23P72 60 Y a PE 60 50 40 30 20 10 0 10 20 30 40 50 60 a X 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 V600 D2KR16 Y V600 D8KRO04 Y i j a 40 30 20 10 0 10 20 30 40 X 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 X V600 D8KR12 y V600 D8KR13 50 suoisueuiig pue suonesyiseds 50 40 30 20 10 0 10 20 30 40 Bo X V600 D8KF04 40 30 20 10 O 10 20 30 40x 40 30 20 10 0 10 20 30 4oX Unit mm RFID System User s Manual 127 Section 6 Appendices Communications Time Communications time differs according to the type of Data Carrier memory SRAM or EEPROM TAT Turn Around Time and transmission time are displayed as communication times TAT represents the total time from when a command is first sent from the host device until a response is received The transmission time represents the time required for communications between the Hand held Reader Writer and the Data Carrier not including communications with the host device Example RDH1 CR RD001122 x CR 1 Transmission time I Command ra Response 1 if I I lu TAT I 4 Bo EN SRAM Data Carrier Reference TAT 8000 7000 6000 5000 Write 4000 3000 Burm 2000 1000 Transmission time ms 0 256 512 768 1024 1280 1536 1792 2048 Number of processing da
39. OMRON RFID System V600 Series User s Manual Hand held Reader Writer V600 CHUD V600 CH1D V2 V600 CH1D PSI C Data Carriers V600 Series Man No Z219 E1 03 Testen Application Considerations Read and understand this information first Product Overview S S 5 e 2 lt Fr 2 fe E Communications Preparations Commands Functions Sa a Troubleshooting Si gt Appendices RFID System V600 CHUD Hand held Reader Writer V600 CH1D V2 Hand held Reader Writer V600 CH1D PSI Hand held Reader Writer V600 Series Data Carriers User s Manual c B E 3 o iz E S Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products Please consult your OMRON representative if you have any questions or comments WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LI
40. Preparations 22 4 V600 CH1D V2 Communications Preparation 36 4 V600 CH1D PSI Communications Preparation 39 44 Communications Test 42 RFID System User s Manual 21 V600 CHUD Communications Preparations Section 2 Communications Preparations V600 CHUD Communications Preparations Connection Connecting the Cable 1 Connect the cable connector to the USB connector on the host device making sure that the connector is oriented correctly and not inserted at an angle e Removing the Cable 1 Remove the cable Close the software application at the host device and then pull out the connec tor in a straight line If the connector is removed while the software is running at the host A device operation may stop due to a software malfunction error CHECK RFID System User s Manual Section 2 Communications Preparations Installing the USB Driver V600 CHUD When connecting the Hand held Reader Writer to the host device for the first time the USB driver must be installed at the host device e Downloading the USB Driver Download the USB Driver for the V680 CHUD from the web site For details ask your OMRON sales representative e Install the USB Driver in the Personal Computer The V600 CHUD supports Windows 2000 and Windows XP operating systems Install the driver in the host device following the procedure corresponding to the OS being used Operation on other OS is not supported W
41. SCII and hexadecimal code can be specified at the same time within a single command frame Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 2 digit hexadecimal The maximum number of bytes that can be read at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 00h to FFh 00 256 bytes When multiple processing areas are used set so that the total number of bytes to be read for all areas is within 256 bytes as follows Area 1 bytes Area N bytes lt 256 bytes RFID System User s Manual Section 3 Commands Response Processing Area Number 1 Command code End code Read data Terminator DEBER s B i x i m 2 2 n 2 Processing Area Number 2 Command Read data Read data code End code area 1 area 2 Terminator Area 1 setting Area 2 setting End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer
42. System User s Manual 7 Section 3 Commands EXPANSION DIVIDED AUTO READ NR This command divides and reads up to 2 Kbytes of data from the Data Carrier when the Hand held Reader Writer is moved close to the Data Carrier The Hand held Reader Writer responds when com munications between the Hand held Reader Writer and Data Carrier have ended The host device can not send commands to the Hand held Reader Writer until all the responses have been received Processing Command pata h mber Read area Number of code setting setting start address read bytes Terminator Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code Processing area number Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters o o c E E o o o c 2 pz G 2 c 3 E E o o Response When the read data is within 250 characters Command code End code Read data Terminator End code Indicates the execution result for the command The end code
43. Y READ RC This command reads data to be copied using the COPY WRITE WC command A response is not sent for read data Processing Command Data see Read area Number of code setting setting start address read bytes Terminator 2 1 1 Oor4 Oor4 2 Data setting Always H Processing area number Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code can be omitted Setting range 0000h to 1FFFh when omitted all areas in the Data Carrier are read Note If omitting the start address also omit the number of read bytes All areas of an 8 Kbytes Data Carrier cannot be copied Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal Setting range 0001h to 0800h Response Command code End code Terminator o o c E E o o o c 2 pz G 2 c 3 E E o o End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List p 101 eU The COPY READ command can be executed more than once for data that has already been copied If the 7 copy operation fails however the copied data that was held will be deleted CHECK RFID System User s Manual Section 3 Commands COPY WRITE WC This command writes data to the Data Carrier that was read usi
44. al Processing area Command Data number code setting setting Write area Number of Specified start address write bytes data Terminator Data setting Always H Processing area number setting Always 1 Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of write bytes Specifies the data to be written to the Data Carrier in 2 digit hexadecimal Setting range 00h to FFh 00 256 bytes Specified data Indicates the data to be written to the Data Carrier Response Command code End code Terminator Pe eee 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List ICE p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 89 o o c E E o o c 2 pz G 2 c 3 E E fe o Section 3 Commands Example Writing 01H to the O6H bytes in the memory area starting from address 0030H for a Data Carrier in which the same data and address is written Process area Command Data number Write area Number of Specified code setting setting start address write bytes data Terminator Response Command code Endcode Terminator RFID System User s Manual 002FH 0030H 0031H 0032H 0033H 0034H 0035H
45. ame CR Succeeding frame CR No succeeding frame Response Command code Endcode Terminator epe 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List il 2 p 101 RFID System User s Manual Section 3 Commands eFrame Division Method If the command length is longer than 266 characters divide the data into separate frames before send ing as follows Frame Division Method Divide the data into frames each with 266 characters max 2 Use the final terminator CR for the last frame frame n only Use the delimiter CR at the end of other frames 3 Be sure to include the command code data setting processing area number setting and start address in the first frame frame 1 If any of these parameters is omitted a command input error will occur The write data can be omitted 4 Make sure that data is divided correctly without any single frames containing AA CR or XZ CR F 266 characters max per frame Frame 1 XW AH 1 Stanaddress weiss Jor Frame 2 Write data 2 Frame n 1 Write data n 1 Frame n Write data n CR Communications Procedure spueuiuo suoneoiunuiuo2 3I SETS Command 1 Command 2 Command n 1 Command n Host a re i UN Hand held Reader Writer Delimiter Delimiter Delimiter Delimiter Response RFID
46. auto command and returns a Data Carrier non existent error error code 72 to the host device When the Auto Command OFF function is not used the auto command will not be aborted even if one minute passes after entering the Data Carrier wait status This function is set using the BASIC FUNCTIONS SETTING FN command 17 Refer to the section on the BASIC FUNCTIONS SETTING FN command for details on the setting method Q CHECK A pee Normal Operation Output Function When the Hand held Reader Writer is operating normally this function turns ON the Data Set Ready DS output to allow the host device to monitor the operating status of the Hand held Reader Writer This function is set using the BASIC FUNCTIONS SETTING FN command Vw o The Normal Operation Output function cannot be used with the V600 CHUD A Refer to section on the BASIC FUNCTIONS SETTING FN command for details on the setting method CHECK p 98 RFID System User s Manual suonounJ 1341M Jopeeg pjleu pueH FAILE 105 b o i o a 106 Section 4 Functions Data Carrier The memory access space available to the Hand held Reader Writer is 0000H to 1FFFH totaling 8 Kbytes The available access space is determined by the Data Carrier memory capacity The allocations for the Hand held Reader Writers manufacturing date area write protect area and control methods for these areas depend on the type of Data Carrier
47. available V600 series Data Carriers is possible eTransmission Distances Data Carrier Transmission distance V600 D23P53 0 to 2 5 mm V600 D23P54 0 to 4 mm V600 D23P55 O to 10 mm V600 D23P61 O0 to 11 mm V600 D23P66N 0 to 17 mm See note 2 V600 D23P66SP O to 12 mm V600 D23P71 0 to 25 mm V600 D23P72 0 to 23 mm V600 D8KR04 0 to 35 mm V600 D8KR12 0 to 25 mm V600 D8KR13 0 to 20 mm V600 D2KR16 Oto 10 mm V600 D8KF04 0 to 18 mm Note 1 Data Carrier Installation Conditions V600 D23P53 P54 Embedded in metal iron V600 D23P55 Embedded in resin V600 D23P61 Metal iron on the back surface of the Data Carrier V600 D23P66N P66SP P71 P72 Resin on the back surface of the Data Carrier Data Carrier no metal on back surface V600 D8KR04 R12 R13 D8KF04 Metal iron on the back surface of the Data Carrier V600 D2KR16 Data Carrier installed on a bracket and attached to a metal aluminium plate Note 2 When using the V600 D23P66N at temperatures of 10 C or lower transmission may not be possible at the specified distance In this case move the Reader Writer slightly further away from the Data Carrier RFID System User s Manual Transmission Range Reference V600 D23P53 y V600 D23P54 y 15 0 a 20 15 10 5 20 15 10 V600 D23P55 V600 D23P61 15 10 5 30 20 10 0 V600 D23P66N V600 D23P66SP as N 40 30 20 10 O 10 20 30 do X 40 30 20 10
48. cifications for TAT data with the host device represent values with a baud rate of 9 600 bps a bit length of 7 bits 2 stop bits and even parity In this example characters are sent consecutively with no spaces between them Note 2 The number of bytes in the TAT data is the number for ASCII encoding RFID System Users Manual 133 Section 6 Appendices Data Carrier Memory Map Data Carrier Memory x 256 Bytes Address Write protect setting area 1 byte Data Carrier Memory gt 256 Bytes Address Data 0000 Manufacturing date area Write protect setting area j 1 byte a gt x o E o 2 x x c o a For more information on Data Carrier memory capacity and memory type refer to Data Carrier Mem ory Capacity and Data Type V600 Series RFID System 4 User s Manual Section 6 Appendices Data Carrier Memory Capacity and Data Type V600 Series As of September 1999 M it Model emomeapaciiy tusar Memory type Life expectancy memory V600 D8KR12 5 years 25 to 70 C V600 D8KR13 2 Kbytes S RAM 8 years 25 to 70 C V600 D8KR04 V600 D2KR16 2 Kbytes SRAM replace 2 years 25 C able battery V600 D23P53 V600 D23P54 V600 D23P55 Overwrite operations 100 000 times V600 D23P61 300 000 times at operating temperature between lower 254 bytes EEPROM limit and 40 C V600 D23P71 V6
49. connec tions and communications Send the test command from the host device x17 For detail on the test command refer to TEST TS e N CHECK A pats wv m If communications is normal the Hand held Reader Writer will return the received data 1s9 suoneoiunuiuo2 FAITS SETS v Ifa response is not returned refer to Troubleshooting Q T z 117 CHECK A P Communications Test Between the Data Carrier and Hand held Reader Writer Use a real command to test communications between the Data Carrier and the Hand held Reader Writer Send the auto read command AR from the host device 17 For details on the auto read command refer to AUTO READ AR Q p 58 CHECK Ie P v The Hand held Reader Writer will communicate with the Data Carrier and the operation indicator will flash green 2 Move the antenna section of the Hand held Reader Writer close to the Data Carrier wv The Hand held Reader Writer will read the data in the Data Carrier when the Hand held Reader Writer moves within the commu nications range As a result the operation indicator will be light green and then turn OFF RFID System User s Manual 43 Communications Test MEMO RFID System User s Manual Section 3 Commands 44 Communications with the Data Carrier 46 44 Command and Response Format 50 44 Communications Commands 54 4X Communications Subcommands 94 4 Host Commands 95
50. ct S The COMMUNICATIONS CONDITIONS SETTING TR command can be used only with the V600 CH1D V2 T Do not use it with the V600 CHUD z CHECK Command Baud Data Parity Stop code rate length bits Terminator Baud rate Sets the baud rate 0 9 600 bps 1 2 400 bps 2 4 800 bps 3 19 200 bps 4 38 400 bps Default setting 9 600 bps Data length Sets the data length 0 7 bits 1 8 bits Default setting 7 bits Parity Sets the parity 0 Even parity 1 Odd parity 2 No parity Default setting Even parity spueululo2 01 U0D 49J OJ3u05 Stop bits Sets the number of stop bits 0 2 bits 1 1 bit Default setting 2 bits Response Command code Endcode Terminator End code Indicates the execution result for the command 00 Normal completion For details on end codes refer to End code List p 101 RFID System User s Manual 97 c G E E o o o 5 o o b 2 5 o o Section 3 Commands BASIC FUNCTIONS SETTING FN This command is used to set the Auto Commands OFF function and Normal Operation Output func tion The Hand held Reader Writer must be restarted to make the changes take effect Only the Auto Command OFF function is supported by the V600 CHUD The Normal Operation Output function is not A supported by the V600 CHUD CHECK Auto Command OFF specification Normal Operation Command Output code
51. ct machine system or other application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty
52. ctions Write Protect Function The write protect function prevents important data stored in the Data Carrier such as the product type and model from being overwritten by other data and lost Use the following methods to set write protection after writing important data EEPROM Data Carriers without Battery Setting the Write Protect Function The write protect function is set by writing the final address to be protected in address 0000H of the Data Carrier s memory The area between address 0001H and the write protect end address will be write protected The status of the most significant bit of address 0000H determines whether or not the write protect function is in effect Address Bit 7 6 5 4 3 2 1 0 Yes 0000 No Write protect Bit Most significant bit of address 0000H 1 Write protected Yes 0 Not write protected No End address setting range 00H 01H to 7FH Address 0080H to OOFFH can therefore not be set as the end address If the end address is set to 00H however all addresses from 0001H to OOFFH will be protected Joey eea Fale Write protect Setting Examples 254 byte Memory Data Carrier 1 The following settings would write protect address Address es 0001H through 0012H 0000 Write protected area 0012 2 The entire memory except address 0000H is write a protected by setting t
53. d held Reader Writer 2 Press the Hand held Reader Writer activate switch 3 The Hand held Reader Writer enters the communication stand by state with the Data Carrier and the operation indicator LED flashes green wu If the Data Carrier is not detected within one minute of sending the command a timeout will occur and a Data Carrier S a Non existent Error will occur As a result the operation indicator will flash red lt CHECK 4 Communications with the Data Carrier are performed when the antenna end of the Hand held Reader Writer is moved near the Data Carrier Joie ejeq eui YUM suoneoiunuiuoo Fae ers 5 A response is returned from the Hand held Reader Writer to the host device If communications end normally the operation indicator LED lights green and then turns OFF RFID System User s Manual 49 Section 3 Commands Command and Response Format The format of commands sent between the host computer and the Hand held Reader Writer and responses returned from the Hand held Reader Writer to the host computer is shown below The command and response both consist of a single frame The frame including the terminator consists of up to 4 106 characters for commands and 4 102 characters for responses 1 frame A Command code Data Terminator x x x x Ur x CR 2 n 2 Name Description Command code Command Contains the two character code see page p 52 Response Contains the same code that was sent with the
54. d humidity range e Locations not subject to direct vibration or shock outside the specified ranges e Locations not subject to water oil or chemicals 2 Installation e The product communicates with Data Carriers using the 530 kHz frequency band Some motors inverters switching power supplies and other devices generate noise that can affect communica tions with the Data Carriers If such devices are located near the Data Carriers communications with the Data Carriers may be adversely affected or the Data Carriers may be destroyed Whenever using the product near devices of this nature always test operation in advance to confirm if the sys tem will be affected e Observe the following precautions to minimize the effects of normal noise 1 Ground all metal objects in the vicinity to 100 Q or less 2 Do not use the system near high voltage or high current lines e Connectors are not waterproof Do not use the product where mists are present e Do not use chemicals that would affect the materials used in the product e Always be sure the USB connector is properly inserted when using the USB port 3 Cleaning e Do not clean the product with thinners benzene or other organic solvents These will dissolve the resin parts and coating on the case RFID System User s Manual Introduction How to Read this Manual Meanings of Symbols V 7 e Indicates particularly important points related to a function including preca
55. e 2 wo 2 77 e RFID System User s Manual W Connect the V600 CH1D V2 to the host device p 36 v we Set the communications parameters between the host device and Hand held Reader Writer p 40 v Perform the communications test between the host device and Hand held Reader Writer p 43 m Perform the communications test between the Data Carrier and Hand held Reader Writer p 43 Check the ambient environment p 122 UA Operate the system using real commands p 45 V600 CH1D PSI e o9 D 2 o Communications preparation Test c e ach E D c E Connect the V600 CH1D PSI to the host device p 39 Wn Set the communications parameters between the host device and Hand held Reader Writer p 40 v Perform the communications test between the host device and Hand held Reader Writer IA p 43 Perform the communications test between the Data Carrier and Hand held Reader Writer RE p 43 Check the ambient environment UR p122 Operate the system using real commands UA p 45 Section 1 Product Overview RFID System User s Manual 1eu2 0 4 uonejedo 19 Operation Flowchart ETSI MEMO RFID System User s Manual Section 2 Communications Preparations 4 V600 CHUD Communications
56. e activate switch is pressed after the Hand held Reader Writer moves close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Command Data number Write area code setting setting start address Write data Terminator Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code Processing area number Always 1 setting Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh Write data Indicates the data to be written to the Data Carrier The maximum number of bytes that can be written at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters spueulUulo2 suoneoiunuluo2 Response Command code Endcode Terminator 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UA p 101 RFID System User s Manual 87 Section 3 Commands Calculation Write CW The Data Carrier s memory data and calculation data is calculated in hexadecimal and the result is written to the Data Carrier If an overflow during addition or underflow during subtraction occurs the data will n
57. ed installation is completed Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for E OMRON RFID USB COM Click Finish to close the wizard v 6 Click the Finish Button RFID System User s Manual 29 V600 CHUD Communications Preparations Checking Installation Check that the driver is correctly installed 1 Connect the Hand held Reader Writer to the personal computer ww 2 On the Start Menu select Control Panel System wv 3 Click the Device Manager Button in the Hardware Tab Page RFID System User s Manual System Properties System Restore Automatic Updates Remote General Computer Name Hardware Advanced Add Hardware Wizard E4 The Add Hardware Wizard helps you install hardware Add Hardware Wizard Device Manager E The Device Manager lists all the hardware devices installed zz on your computer Use the Device Manager to change the properties of any device Driver Signing Device Manager Hardware Profiles E Hardware profiles provide a way for you to set up and store different hardware configurations Hardware Profiles 4 Select Ports COM amp LPT and check that OMRON RFID USB COM is displayed The driver is correctly installed if this port is displayed Device Manager Ele Action view Help gt SF e amp lt Rea 2 OMRON 0KRACO230
58. ed information on V600 CH1D PSI 02A April 2014 Deleted information about the Regulations and Standards and made other minor corrections 03 March 2015 Changed the type of Hand held Terminal manufactured by Zebra Technologies Inc RFID System User s Manual Authorized Distributor
59. en to the Data Carrier The characters in ASCII indicate the number of write bytes and the characters in hexadecimal code indicate the number of write bytes x 2 RFID System User s Manual Response Command code 2 End code Terminator 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List RA p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 65 Section 3 Commands BUTTON AUTO READ UR After this command is received by the Hand held Reader Writer data will be read from the Data Carrier after the activate switch is pressed and the Hand held Reader Writer is close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Area Number 1 Processing area Command Data number Read area Number of Code setting setting start address read bytes Terminator o z G Processing Area Number 2 Processing o Command Data M Read area Number of Data Read area Number of o code Setting setting start address read bytes setting start address read bytes Terminator o c o z G 2 z Area 1 setting Area 2 setting E Data setting Sets the code format used to send responses for read data o A ASCII H Hexadecimal code When multiple processing areas are used A
60. er of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters o o c E E o o o c 2 pz G 2 c 3 E E o o Response When the read data is within 250 characters Command code End code Read data Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UE p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual When the read data is 251 characters or higher Section 3 Commands The data received from the host device is divided into frames according to the delimiters CR as shown in the following diagram ix 256 characters max per frame P 250 characters Frame 1 XR i 00 Read data 1 E 254 characters 5ei Frame 2 Read data 2 Frame Read data n 1 n 1 E M 254 characters max gt Frame n Read data n ik CR Communications Procedure Command Delimiter Delimiter Delimiter Delimiter Ho
61. erior portability and operability RFID System User s Manual Section 1 Product Overview Names and Functions of Components V600 CHUD Antenna Operation Indicator LED A Display Meaning Operation indicator LED A command has been received from the host device Communications with the Data Carrier have completed normally C The execution result of the noise detection command NS is A low 0 Activate switch Litoreen noise The result of the error noise detection command EN is 0 normal When the power is turned ON after initialization of the Hand held Reader Writer is completed Communications with the Data Carrier are in progress Flashing green A communications error with the Data Carrier has occurred C A CPU error has occurred sjueuoduio jo suonoun4 pue sowen T Lit red U A Data Carrier non existent error has occurred A communications error with the host device has occurred d The execution result of the noise detection command NS is B high noise Flashing red The result of the error noise detection command EN is 1 error Interface connector st After the operation indicator is lit or flashing for a certain time it will turn OFF e z CHECK eActivate Switch When button commands button commands button auto commands are used and the activate switch is p
62. gh temperature and high pressure water which is defined 3 by the German standard DIN 40050 PART9 p E Water is sprayed on 80 C hot water with the water pressure of 80 to 100BAR from a nozzle to the i test piece aaa Amount of water is 14 to 16 liters minute a The distance between the test piece and a nozzle is 10 to 15 cm and the directions of water y drainage are 0 degrees 30 degrees 60 degrees and 90 degrees horizontally They are evaluated with the test piece is rotating on a horizontal plane by 30 seconds in each direction Oil resistance OMRON in house standard Protection Oil resistant No adverse affect from oil drops or oil spray approaching from any direction Oil proof Protects against penetration of oil drops or oil spray approaching from any direction Note Oil resistance has been tested using a specific oil as defined in the OMRON test method JIS C 0920 2003 Appendix 1 RFID System User s Manual 138 MEMO RFID System User s Manual uonoojoJd jo eo16og 139 140 Revision History A manual revision code appears as a suffix to the catalog number at the bottom of the front and rear pages Man No Z219 E1 03 Revision code Revision code Date Revised contents 01 February 2005 Original production Added information on installing the USB driver for Vista 9a September 2008 A dded information on V600 CH1D V2 V600 A22 and V600 D8KF04 Add
63. he activate switch is pressed P RC COPY READ Reads data to be copied using the COPY WRITE command from the 70 Data Carrier P WC COPY WRITE Writes the data read using the COPY READ command to the Data 1 Carrier P XR EXPANSION Divides and reads up to 2 Kbytes of data from the Data Carrier 72 DIVIDED READ zi XW EXPANSION Divides and writes up to 2 Kbytes of data to the Data Carrier 74 DIVIDED WRITE p NR EXPANSION Divides and reads up to 2 Kbytes of data from the Data Carrier when DIVIDED the Data Carrier enters the communications area p 76 AUTO READ NW EXPANSION Divides and writes up to 2 Kbytes of data to the Data Carrier when the DIVIDED Data Carrier enters the communications area p 78 AUTO WRITE rd EXPANSION Reads up to 2 Kbytes of data from the Data Carrier in a batch 80 BATCH READ p wt EXPANSION Writes up to 2 Kbytes of data to the Data Carrier in a batch 81 BATCH WRITE P ar EXPANSION Reads up to 2 Kbytes of data from the Data Carrier in a batch when the BATCH Data Carrier enters the communications area p 82 AUTO READ aw EXPANSION Writes up to 2 Kbytes of data to the Data Carrier in a batch when the BATCH Data Carrier enters the communications area p 83 AUTO WRITE br EXPANSION Reads up to 2 Kbytes of data from the Data Carrier in a batch after the BATCH activate switch is pressed p 84 BUTTON READ bw EXPANSION Writes up to 2 Kbytes of data to the Data Carrier in a batch after the BATCH activate switch is pressed p 85 BUTTON WR
64. he conditions thoroughly then accurately determine the likelihood of the error re occurring whether the problem is related to another device and other factors causing the error and refer to the following flowcharts for troubleshooting i N C START J y Connect to the host device Check whether the USB connector is connected correctly e operation indicator is not flashing green although the connection is correct NO gt fth tion indicator is not flashing g Ithough th tion i t the host device or the Hand held Reader Writer may be faulty Is the operation indicator flashing green Y E S Send TEST command TS from host device Check the communications port settings Ne G p 26 p 30 If communications with the Hand held Reader Writer are not possible even if the YES settings are correct the USB driver may not be installed correctly or the host device host device software or Hand held Reader Writer may be faulty Is response normal Y Send the AUTO READ command AR from the host device and move the Hand held Reader Writer close to the Data Carrier Error code 7A The address specification is incorrect Check the AR command address and resend the command from the host device Ez p 58 Error code 70 or 72 Replace the Data Carrier with one that operates normally and resend the command YES If the error occurs again replace the
65. he end address to 00H as shown below Address Example When the end address is 00H 0000 Address Bit 7 6 5 4 3 2 1 0 Write 1 0 0 0 0 0 0 0 protected 0000 5 area 00FD Canceling Write Protection To cancel write protection turn OFF the most significant bit of address 0000H The write protection will be cancelled and the address set in 0000H will be ignored st Address OOOOH is the write protection setting area Therefore always structure the data so that any data that needs to E be write protected is written in addresses starting from 0001H z CHECK RFID System User s Manual 107 xx o x c o a 108 Section 4 Functions eSRAM Data Carriers with Built in Battery Setting Write Protect Function The write protect function is set in the four bytes of addresses 0002H through 0005H of the Data Carriers memory The status of the most significant bit of address 0002H determines whether or not the write protect function is enabled Address Bit 7 6 5 4 3 2 1 0 0002 E Upper two digits of start address 0003 Lower two digits of start address 0004 Upper two digits of end address 0005 Lower two digits of end address Write protect Bit most significant bit of address 0002H 1 Data is write protected 0 Data is not write protected Write Protect Setting Area Start address 0006H to 1FFFH End address 0006H to 1FFFH Settings to write protect addresses 0006H through 07FF
66. he specified one may cause a malfunction damage or fire in the V600 CH1D V2 e Some host devices require a conversion connector CHECK RFID System User s Manual 37 V600 CH1D V2 Communications Preparation Section 2 Communications Preparations When connecting to a CQM1 CJ1 CS1 etc Prepare a connection cable as shown in the connection examples below Note Because both the V600 CH1D V2 interface connector and the interface connector of the CQM1 CJ1 and CS1 are sockets a conversion connector is necessary to connect them Also the pin arrangement of the CQM1 CJ1 and CS1 interface connector is different from the RS 232C pin arrangement of a personal computer V600 CH1D V2 Pin No Signal CQM1 CJ1 CS1 Signal RD SD SD RD RS SG cs DS RS CS OO CO NI OD om A w N RFID System User s Manual cio o om A w N Section 2 Communications Preparations V600 CH1D PSI Communications Preparation Pin Arrangement of the Host Device Interface Connector V600 CH1D PSI Code Pin No Signal See Signal direction note lt 1 o e 2 Receive data RD Hand held Reader Writer to 5 host device I Send data SD Host device to Hand held o 3 D Reader Writer U i o Oo 5 Signal ground SG S 8 6 Data set ready DS Hand held Reader Writer to 3
67. host device 5 7 Request send RS Loops inside connector S 8 Enable send CS 5 5 VDC m Host device to Hand held d 9 v Reader Writer a Note The names of signals at the host device are abbreviated with codes RE S L o 3 Connection with the Host Device Use the following procedure to connect the V600 CH1D PSI to the host device 1 1 Connect the V600 CH1D PSI to the RS 232C interface of the host device EL WO nr RFID System User s Manual 3 V600 CH1D PSI Communications Preparation Section 2 Communications Preparations Setting the Hand held Reader Writer eSettings The following settings are used to operate the Hand held Reader Writer Serial communications parameters data transfer speed parity check stop bits Basic function settings Auto Command OFF and Normal Operation Output functions These settings can be changed by using a setting command from the host device To operate the Hand held Reader Writer with the new setting the power must be turned OFF then ON again or the ABORT command must be used Serial Communications Parameters The following are the settings related to serial communications Use the COMMUNICATIONS CONDI TIONS SETTING TR command Item Contents Baud rate bps 2400 4 800 9 600 see note 19 200 38 400 Transmission code 7 unit ASCII 7 see note or 8 unit JIS 8 Parity check Even parity see note odd parity none Stop bits 2 see note 1
68. ife Detection e z bs CHECK B B RFID System User s Manual 93 Section 3 Commands Communications Subcommands Communications subcommands are used together with communications commands Communications with the Data Carrier cannot be performed using only these subcommands COMMAND PROCESSING TERMINATE AA Terminates the processing of the communications commands and error noise detection commands and restores the command wait status Command Command code Terminator CR Response gt N gt Command Termination code End code timing Terminator End code Indicates the execution result for the command 00 Normal completion 15 Command processing not executed Communications Subcommands gt N gt E3 O D For details on end codes refer to End code List il z p 101 Termination timing Indicates the timing for terminating command processing 0 Terminated before Data Carrier detection 1 Terminated during Data Carrier detection RFID System User s Manual Section 3 Commands Host Commands TEST TS This command returns test messages sent from the host device without changing anything The TEST command is used for communications tests between the host device and the Hand held Reader Writer Command code Message data Terminator 2 n 2 Message data Any text string for testing communications containing 514 characters max Response Command code End code
69. indows 2000 1 Turn ON the power to the personal computer and start Windows 2000 wv 2 Connect the Hand held Reader Writer to the personal computer X For details on connection methods refer to V600 CHUD Communications Preparations e Nse p 22 CHECK p suonesedaig suoneorunuiuo qnH2 009A The following window will be displayed when the Hand held Reader Writer is connected gt V600 CHUD CON Sah Installing wv 3 When the following window is displayed click the Next Button Found New Hardware Wizard RE Welcome to the Found New Hardware Wizard This wizard helps you install a device driver for a hardware device To continue click Next RFID System User s Manual 23 V600 CHUD Communications Preparations wv 4 Select Search for a suitable driver for my device recommended and then click the Next Button Found New Hardware Wizard Install Hardware Device Drivers A device driver is a software program that enables a hardware device to work with an operating system v 5 Select Specify a location and then click the Next Button Found New Hardware Wizard Locate Driver Files Where do you want windows to search for driver files ak im Smm wv 6 Click the Browse Button and select the folder in which the downloaded file RFID Win2kcom inf is saved Found New Hardware Wizard x ea Basel ewe wv RFID System 24 User s Manual
70. is completed e When the power is turned ON and the reset button is pressed for two seconds or more initialization stand by mode Flashing green Communications with the Data Carrier are in progress A communications error with the Data Carrier has occurred A CPU error has occurred Lit red A Data Carrier non existent error has occurred c A communications error with the host device has occurred Flashing red V After the operation indicator is lit or flashing for a certain time it will turn OFF CHECK eActivate Switch When button commands button commands button auto commands are used and the activate switch is pressed communications with the Data Carrier will commence For details on button commands refer to Section 3 Commands When the activate switch is pressed with the Hand held Reader Writer in the initialization stand by mode with the green LED flashing the function settings will be initialized Reset Button Press this button for two seconds or more when the power is first turned ON to put the Hand held Reader Writer into the initialization stand by mode eAC Adaptor Connection Jack This is a connection jack for the V600 A22 AC Serial Interface Connector This is a serial interface with an RS 232C compliant D Sub 9 pin connec tor eAntenna To communicate with the Data Carrier move the antenna head closer to it RFID System User s Manual sjueuodui
71. ist LZ p 101 Settings for TR command Baud rate 9 600 bps 2 400 bps 4 800 bps 19 200 bps 38 400 bps 7 bits 8 bits Data length OoO fR WN O Parity Even parity Odd parity No parity 2 bits 1 bit Auto Command OFF used Auto Command OFF not used Stop bits Oj N O Settings for FN command Auto Command OFF Specification oO Normal Operation Output Specification 0 Normal Operation Output used Normal Operation Output not used System data S1000000 RFID System User s Manual spuewwog 041UO2 49J OJ3u05 99 Section 3 Commands Other Commands UNDEFINED COMMAND RESPONSE IC This command is returned as the response when the Hand held Reader Writer cannot read the com mand header Response Command code End code Terminator 2 2 2 Error Response If an error occurs during communications with the host device or the Data Carrier error notification is provided in the end code Response Command code End code Terminator o o c E E o o b o E pz o RFID System 00 User s Manual Section 3 Commands End code List End codes are indicated in 2 digit hexadecimal code Status End code Meaning Normal 00 Normal completion 7B Battery low warning indicating that battery replacement is required See note 1 Host communications error 10 See
72. it of the Data Carrier If the battery low check is performed every time access is made battery power is also consumed It is recommended that this be included as a routine check once a day when creating system programs 2 The access method for performing a battery low check can only be performed when the two bytes of 77 data from addresses 0000H to 0001H are read Execute one of the following commands to perform a 9 battery low check 3 A Battery low Check Commands S a READ command RD H A1 0000 02 CR zi b AUTO READ command AR H A1 0000 02 CR 3 c BUTTON READ command BR H A1 0000 02 CR g d BUTTON AUTO READ command UR H A1 0000 02 CR e COPY READ command RC H A1 0000 0002 CR f EXPANSION DIVIDED READ command XR H A1 0000 0002 CR g EXPANSION DIVIDED AUTO READ command NR H A1 0000 0002 CR h EXPANSION BATCH READ command rd H A1 0000 0002 CR i EXPANSION BATCH AUTO READ command ar H A1 0000 0002 CR j EXPANSION BATCH BUTTON READ command br H A1 0000 0002 CR k EXPANSION BATCH BUTTON AUTO READ command ur H A1 0000 0002 CR 3 Response for Low Battery When the battery is low 7B is given in the end code section within the response format Example Normal Battery Low RD 00 0995 CR RD 7B 0992 CR AR 00 0995 CR AR 7B 0992 CR Normal Read data Battery low Read data end code Manufactured error code Manufactured September 1995 September 1992 A battery low check is performed for V600 D2KR16 Data Carriers with re
73. l l l Data Carrier L Da JL jv L I l Command aa Process Start address Write data Terminator SEU Praes Address setting setting oro 9 0011 e aaa 1 byte RFID System User s Manual ewo asuodsay pue puewwoy 51 x o LL o o c o a o o tc xo c xe c E E fo o Section 3 Commands Command List Commands can be classified into four major types eCommunications Commands The following commands are used for communications with the Data Carrier Command code Command name Function Page RD READ Reads memory data from the Data Carrier p 54 WT WRITE Writes data to the memory of the Data Carrier p 56 AR AUTO READ Reads data from the Data Carrier when the Data Carrier is within the 58 communications area p AW AUTO WRITE Writes data to the memory of the Data Carrier when the Data Carrier is 60 within the communications area P BR BUTTON READ Reads data from the memory of the Data Carrier when the activate 62 switch is pressed P BW BUTTON WRITE Writes data to the memory of the Data Carrier when the activate switch 64 is pressed p UR BUTTON AUTO Reads data from the Data Carrier when the Data Carrier enters the 66 READ communications area after the activate switch is pressed P UW BUTTON AUTO Writes data to the memory of the Data Carrier when the Data Carrier 68 WRITE enters the communications area after t
74. memory used SRAM or EEPROM vt For details on the Data Carrier refer to the Appendices or the Read Write Head and Data Carrier Manuals Cat No Z127 E1 Z128 E1 e Y il z p 121 CHECK Manufacturing Date Format Default Setting Using SRAM Built in Battery Data Carrier The date of manufacture is registered in the first 2 bytes of the memory area which control the Data Carrier battery life This area can be read but cannot be written to by the user If a writing operation mistakenly occurs an error error code 7D will result Manufacturing Date Area Address Bt 7 6 5 4 3 2 1 0 pace Second digit of First digit of month month 0001 Second digitof First digit of year year Note 1 The year of manufacture is represented by the last two digits of the year for example 92 for 1992 2 The month of manufacture is represented by two digits for example 03 for March and 10 for October 3 Years from 2000 onwards are represented beginning with 00 for example 0400 for April 2000 and 1204 for December 2004 Example Manufacturing Date of September 1992 Address Bit 7 6 5 4 3241 0 0 0 0 0 1 0 0 1 0000 0 9 10 0 10 0 0 1 0 0001 Using EEPROM Without Battery Data Carrier There is no manufacturing date area The start address is a write protected area RFID System User s Manual Section 4 Fun
75. n not send commands to the Hand held Reader Writer until all the responses have been received Frame 1 Processing area Command Data number code Setting setting Write area start address Write data Terminator Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code S Processing area number Always 1 setting 8 Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh c o Write data Indicates the data to be written to the Data Carrier T Data can be between 0 and 257 characters o E Terminator Indicates the end of the frame z CR Succeeding frame r CR No succeeding frame o o Frames 2 to n Write data Terminator x x x x x x x x CR n 10r2 Write data Indicates the data to be written to the Data Carrier Data can be between 0 and 265 characters Terminator Indicates the end of the frame CR Succeeding frame CR No succeeding frame Response Command code End code Terminator End code RFID System User s Manual Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List p 101 Section 3 Commands eFrame Division Method If the command length is longer than 266 characters divide the data into separate frames before send
76. nd code 72 Data Carrier non existent will be returned Processing Command Data DET Write area code setting setting start address Write data Terminator Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code Processing area number Always 1 setting Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh Write data Indicates the data to be written to the Data Carrier The maximum number of bytes that can be written at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters spuewwoy suoneoiunuluo2 Response Command code Endcode Terminator 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UR p 101 RFID System User s Manual 85 Section 3 Commands EXPANSION BATCH BUTTON AUTO READ ur After this command is received by the Hand held Reader Writer up to 2 Kbytes of data will be read from the Data Carrier in a batch when the activate switch is pressed after the Hand held Reader Writer moves close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended
77. ndcode Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List ILA p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 57 Section 3 Commands AUTO READ AR This command reads data from the Data Carrier when the Data Carrier enters the communications area The Hand held Reader Writer responds when the communication between the Hand held Reader Writer and Data Carrier has ended Processing Area Number 1 Processing Command Data emoe Read area Number of code Setting Setting start address read bytes Terminator Processing Area Number 2 H Hexadecimal code o 2 Processing G Command Data numba Read area Number of Data Read area Number of code Setting Setting start address read bytes setting start address read bytes Terminator E o o o c 9 5 Area 1 setting Area 2 setting S Data setting Specifies the code format used to send responses for read data E A ASCII E o o When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FF
78. ng the COPY READ RC com mand The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Command Processing area Command Data number code setting setting Terminator Data setting Always H Processing area number Always 1 setting The end code 00 indicates normal completion Oo o 3 3 Response c Command Q code End code Terminator o Pele else 2 2 2 9 End code Indicates the execution result for the command 3 o 2 a o For details on end codes refer to End code List UA p 101 RFID System User s Manual 71 Section 3 Commands EXPANSION DIVIDED READ XR This command divides and reads up to 2 Kbytes of data If the Data Carrier is not in communications range an error response end code 72 Data Carrier non existent will be returned The host device cannot send commands to the Hand held Reader Writer until all the responses have been received Processing Command pata number Read area Number of Code setting setting start address read bytes Terminator 2 1 1 4 4 2 Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code Processing area number Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh Numb
79. nnectors connector Series A plug connection status USB specifications Ver 1 1 Baud rate Full speed 12 Mbps Device class COM class Vendor ID Hexadecimal format 0590 Product ID Hexadecimal format 0048 st Use the host communications interface as the COM port for the host device CHECK V600 CH1D V2 V600 CH1D PSI Specification V600 CH1D V2 V600 CH1D PSI Connector D Sub 9 pin applicable to IBM PC AT or compat D Sub 9 pin ible See note 1 Standard compliance RS 232C Transmission line 1 1 connection Communications Two wire half duplex method Synchronization Asynchronous stop bit 1 or 2 See note 2 method Baud rate 2 400 4 800 9 600 19 200 38 400 bps See note 2 Transmission code 7 unit ASCII or 8 unit JIS See note 2 Communications 1 1 control Error detection Vertical parity even odd none See note 2 Note 1 For conversion to a 25 pin connector use the SGC X9P 25P 2 manufactured by Sunhayato or an equivalent Note 2 Set by a settings command RFID System User s Manual suoisueuiig pue suonesyioeds REISEN 123 Section 6 Appendices Dimensions V600 CHUD 45 e O 25 5 23 L C413 LH 25 d m t 11 65 gt 19000 23 att
80. o jo suonoun pue sauieN 13 Section 1 Product Overview System Configuration V600 CHUD The V600 CHUD Hand held Reader Writer can communicate with host devices that have a USB interface such as personal computers Host Devices c o x 2 2 y c o o E o o gt o Personal computer Handheld Reader Writer Data Carriers The V600 CHUD Hand held Reader Writer can be used with any Data Carrier in the V600 Series st For details on Hand held Reader Writer and Data Carrier models refer to Section 6 Appendices em Bus zi p 122 p 135 RFID System 14 User s Manual Section 1 Product Overview V600 CH1D V2 A built in RS 232C serial interface in the V600 CH1D V2 Hand held Reader Writer allows communications with personal computers and programmable controllers that are equipped with an RS 232C interface Host Devices Programmable controller Some models require a conversion connector Personal computer uoneanBijuo uie s S Hand held Reader Writer V600 CH1D V2 V600 A22 option Data Carriers The V600 CH1D V2 Hand held Reader Writer can be used with any Data Carrier in the V600 Series st For details on Hand held Reader Writer and Data Carrier models refer to Section 6 Appendices S m UA p 122 p 135 RFID System User s Manual 15 c o 5 x 3 o c o o E o o gt o 16 Section 1 Product Overview
81. o send responses for read data A ASCII H Hexadecimal code Processing area number Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters o o c E E o o o c 2 pz G 2 c 3 E E o o Response Command code End code Read data Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List JURA p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual Section 3 Commands EXPANSION BATCH BUTTON WRITE bw After this command is received by the Hand held Reader Writer up to 2 Kbytes of data will be written to the Data Carrier in a batch when the activate switch is pressed If the activate switch is pressed and the Data Carrier is not in communications range an error response e
82. oduct CREDA Protects against penetration of all dust uonoojoJd Jo 391690 KENEEN Degree Protection Test method with fresh water 0 No protection Not protected against water No test 1 Protection against water Protects against vertical drops Water is dropped vertically drops of water towards the product towards the product from n the test machine for 10 O min 2 Protection against water Protects against drops of Water is dropped for 2 5 drops water approaching at a maxi min each i e 10 min in B mum angle of 15 to the left total towards the product L right inclined 15 to the left back and front of vertical right back and front from towards the product the test machine 3 Protection against sprinkled Protects against sprinkled Water is sprinkled at a Water rate is 0 07 liter min water water approaching at a maxi maximum angle of 60 to per nale mum angle of 60 from verti the left and right from verti cal towards the product cal for 10 min from the test machine RFID System User s Manual 137 Section 6 Appendices Degree Protection Test method with fresh water 4 Protection against water Protects against water spray Water is sprayed at any Water rate is 0 07 liter min spray approaching at any angle angle towards the product per hole towards the product for 10 min from the test machine 5 Protection against
83. of bytes to be written to the Data Carrier in 2 digit hexadecimal The maximum number of bytes that can be written at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 01h to FFh When multiple processing areas are used set so that the total number of bytes to be written for all areas is within 256 bytes 6 bytes as follows Area 1 bytes Area N bytes lt 256 bytes Write data Indicates the data to be written to the Data Carrier The characters in ASCII indicate the number of write bytes and the characters in hexadecimal code indicate the number of write bytes x 2 RFID System User s Manual Response Command code 2 Endcode Terminator DUDAS 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UR p 101 RFID System User s Manual spueululo2 suoneoiunuluo2 61 Section 3 Commands BUTTON READ BR After this command is received by the Hand held Reader Writer data is read from the Data Carrier by pressing the activate switch If the activate switch is pressed and the Data Carrier is not in communica tions range an error response end code 72 Data Carrier non existent will be returned Processing Area Number 1 Processing Command Data number Read area Number of code
84. ot be written and an error response end code 76 Data check error will be returned Processing Number of area i i Command Data number Calculation area calculation code Setting setting start address area bytes Calculation data Terminator 2 1 1 4 2 Specified number of bytes 2 Processing specification Specifies the calculation method A Add hexadecimal S Subtract hexadecimal Processing area number Always 1 e 5 setting E Calculation area start Specifies the start address of the area to be written to in 4 digit hexadecimal E address Setting range 0000h to 1FFFh B Number of calculation Specifies the number of bytes in the area for calculating data in 2 digit hexadecimal S area bytes Setting range 01h to 04h Calculation data Specifies the numerical values to be calculated in hexadecimal o 2 E Response o o Command code End code Calculation data Terminator epo nm 2 2 Specified number of bytes 2 Calculation data Returns the calculation result data written to the Data Carrier If an overflow during addition or underflow during subtraction occurs the end code 76 data check error will be returned The data prior to the calculation will not be added to the response RFID System User s Manual FILL FL Section 3 Commands This command writes one byte of specified data to the specified memory area of the Data Carrier The write data is specified in hexadecim
85. parations eReset Procedure Turn ON the power while pressing the reset button Keep the reset button depressed for two seconds or more The green operation indicator will start flashing With the green operation indicator flashing remove your finger from the reset button and press the acti vate switch When the activate switch is pressed the operation indicator will stop flashing green This indicates that all of the settings have been initialized Note If the activate switch is not pressed within 30 seconds from the time that the operation indicator starts flashing green the settings will not be initialized RFID System User s Manual uone4edaad suoneorunuiuo ISd QLH2 009A 41 Communications Test Section 2 Communications Preparations Communications Test Test Run Procedure Connect the Hand held Reader Writer to the host device Visually check the indicator display Execute the online test from the host device Check communications between the host device and Hand held Reader Writer using the test command Test run the system Check operation using real commands RFID System User s Manual Section 2 Communications Preparations Communications Test Between Host Device and Hand held Reader Writer Use the test command to test communications between the Hand held Reader Writer and host device Before performing communications with the Data Carrier check the Hand held Reader Writer
86. parison are made using the check block units specified by the user The CRC code is calculated from the generated polynomial expression x16 x24 XS 1 The calculation area is the portion of the check Address block specified by the start address and the iin number of bytes excluding the last two bytes The last two bytes are the check code area Area start When check code write is specified Addon transaction code K the CRC of the Check code calculation area calculation area data is calculated and written Em Number of check to the check code area When data comparison block bytes Mio E is specified transaction code C the CRC of u the calculation area data is calculated and a CRC upper digit Check code area 2 bytes CRC lower digit comparison made with the check code area data If they coincide end code 00 is returned A aL indicating normal transmission and if they do not coincide end code 76 is returned as a warning b o i o a vst For details on the command format refer to DATA CHECK MDC K Q ka z 92 CHECK IE p Example Using the Data Carrier s DATA CHECK Command In the following example the data in address 0010H to 0012H is checked 1 In this example the following data already exists in 2 Execute MDK1001005 calculation transaction the memory The CRC code 5CD6 calculated from the data 123456 is
87. placeable batteries when the READ WRITE commands are executed regardless of the addresses RFID System User s Manual 111 Section 4 Functions Data Carrier Life after Low Battery Signal Occurs After a battery low signal is sent the Data Carrier can be used for approximately one month in the normal operating state The Data Carrier should be replaced however as soon as possible S The SRAM Data Carrier except the V600 D2KR16 is equipped with a thionyl chloride lithium battery A characteristic A of the thionyl chloride lithium battery is that the internal resistance of the battery increases when the battery is left lt SHEI unused for several months If this occurs and a Data Carrier battery low check is performed a low battery response may be returned regardless of whether battery life still remains This is a result of the increased resistance within the battery and is not due to the battery life expiring If a Data Carrier has been left for several months after purchase with out being used use the read operation for approx 10 minutes to activate the battery before use Current will flow in the battery and resistance in the battery will return to normal as a result of activating the battery The life of the battery will hardly be affected When using V600 D2KR16 Data Carriers with replaceable batteries the Data Carrier can be used for approximately two weeks in the normal operating state The battery should be re
88. placed however as Soon as possible eEEPROM Data Carrier without Battery The OVERWRITE COUNT CONTROL command MDS can determine whether the overwrite count for the EEPROM Data Carrier has been exceeded By executing the OVERWRITE COUNT CONTROL command the number of overwrites is decremented from the data in the specified overwrite count control area and whether the data has exceeded the limits is determined b o i o a The overwrite count control area consists of 3 bytes from the start address The decrement value from the overwrite count is written in this area and if this value Area start address Upper digit is 0 OOH an end code 76 will be given as a warning SERT Therefore to enable control of the number of overwrites the maximum number of overwrites must be written to the overwrite count control area beforehand The user specified number of overwrites can be set to up to 16 700 000 The number of overwrites in the specifications for EEPROM Data Carriers however is 300 000 overwrites 0493E0H at 40 C max so be sure to set the number of overwrites to 300 000 or lower The number of overwrites is controlled using hexadecimal values and can be read using the READ command If the control area data is already O the control area value will not be refreshed and only a warning will be returned as a response When the refresh count is set as OOH the count will not be updated and only an overw
89. pted Non fatal Errors Operation Continues If a non fatal error occurs the operation indicator will be lit red or flashing red and an error code will be returned to the host device Name Operation indicator Description Parity error Flashing red A parity error has occurred in communications with the host device Framing error Flashing red A framing error has occurred in communications with the host device Overrun error Flashing red An overrun error has occurred in communications with the host device Format error Flashing red The command from the host device was incorrectly formatted Frame length error Flashing red Command exceeding the maximum frame length was received Data Carrier communica Lit red Communications with the Data Carrier could not be performed correctly tions error Mismatch error Lit red Write control was not performed correctly Data Carrier non existent Flashing red A command that was not an auto command was sent when the Data Car error rier was not in the communications area A command OFF occurred with the auto command Address error Lit red An address that exceeded the Data Carrier memory area was designated Write protect error Lit red The manufacturing date area or the write protect area was designated with a WRITE command RFID System User s Manual Section 5 Troubleshooting Troubleshooting Flowchart If an error occurs be sure to understand t
90. r 8 min utes each Shock resistance 150 m s approx 15G 3 times each in 6 directions up down right left forward reverse Insulation resistance 50 MQ min at 500 VDC between connector terminals and case Dielectric strength 1 000 VAC 50 60 Hz for 1 min between connector terminals and case leakage current 1 mA max Cable length 0 8 m 1 9 m 2 5m 0 8m Note This does not include the connector section The main unit is not resistant to chemicals or oils Performance Specifications Diagnostic function Checks for CPU errors V600 A22 Specifications Item Input voltage Specification 100 to 120 VAC at 50 60 Hz Input current 200 mA 20 100 VAC 170 mA 20 120 VAC ture Output voltage 5 VDC 0 25 V Ambient operating temper 0 to 40 C ature Ambient storage tempera 40 to 70 C Ambient storage humidity 25 to 85 Insulation resistance 100 MQ min at 500 VDC between input terminals and output terminals Dielectric strength 1 500 VAC for 1 min between input terminals and output terminals leakage current 5 mA max Weight Approx 85 g Applicable standards UL and CSA RFID System User s Manual Section 6 Appendices Communications Specifications Host Communications Interface Specifications V600 CHUD Item Specification Co
91. r Memory Map 134 Data Carrier Memory Capacity and Data Type V600 Series 135 List of ASCII Characters 136 Degree of Protection 137 140 Revision History RFID System User s Manual Section 1 Product Overview MIITSET 44 Features 10 4x Names and Functions of Components 11 4 System Configuration 14 Operation Flowchart 17 RFID System User s Manual Section 1 Product Overview Features The V600 CHUD Hand held Reader Writer incorporates a V600 series Antenna and Controller into a compact device conforming to USB 1 1 Data can be read from or written to the Data Carrier simply by approaching or touching the Data Carrier with the Hand held Reader Writer o o i gt o LL Hand held Terminal manufactured by Zebra Technologies Inc Hand held Terminal Recommended for the V680 CH1D PSI Work About Pro Data Carriers e V600 CHUD This Hand held Reader Writer provides a USB connector that conforms to the USB 1 1 standard Con necting the Hand held Reader Writer to a personal computer or Hand held Terminal gives it superior portability and operability e V600 CH1D V2 A built in RS 232C interface allows this Hand held Reader Writer to be connected to a personal com puter or programmable controller e V600 CH1D PSI A built in RS 232C interface allows this Hand held Reader Writer to be connected to a Hand held Ter minal giving it sup
92. rence eTAT 2000 x Write 1500 Se oO E 1000 o E E 2 500 Read 0 0 32 64 96 128 160 192 224 256 Number of processing data bytes eTransmission Time 2000 ms 1500 Write 1000 Head 500 Transmission time 0 32 64 96 128 160 192 224 256 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 3 8N 61 2 Write T 5 8N 69 9 o c S 7 c o E a Uv c 0 c o 2 E o o 2 o N Number of processing RFID System 132 User s Manual Section 6 Appendices eFe RAM Data Carrier Reference eTAT 8000 7000 Write E 6000 No o 5000 4000 lt 8 3000 E Read 2000 1000 0 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes eTransmission Time 8000 1099 Write 6000 E 5000 4000 x 3000 2000 1000 Read Transmission time ms 0 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 1 5N 61 6 Write T 3 5N 75 8 suoisueuiig pue suonesyioeds RESEN N Number of processing Note 1 Communications spe
93. reparation Pin Arrangement of the Host Device Interface Connector V600 CH1D V2 Code Pin No Signal See Signal direction note 1 2 Receive data RD Hand held Reader Writer to host device 3 Send data SD Host device to Hand held Reader Writer 4 5 Signal ground SG d 8 6 Data set ready DS Hand held Reader Writer to host device 7 Request send RS Loops inside connector 8 Enable send CS 9 Note The names of signals at the host device are abbreviated with codes Note For conversion to a 25 pin connector the SGC X9P 25P 2 manufactured by Sunhayato or an equivalent is recommended RFID System User s Manual Section 2 Communications Preparations eConnection with the Host Device Use the following procedure to connect the V600 CH1D V2 to the host device 1 Connect the V600 CH1D V2 to the RS 232C interface of the host device When connecting to an IBM PC AT or compatible When connecting to a PC9801 series computer D Sub 25 pin connector To convert from a 9 pin connector to a 25 pin connector use an SGC X9P25P 2 conversion connec tor manufactured by Sunhayato or an equivalent product SGC X9P25P 2 uonesedaig suoneoiunuiuo2 zZA QLH2 009A wv EN V600 A22 wv 3 Plug the V600 A22 AC Adaptor into a 100 to 120 VAC power outlet V e Do not use any AC adaptor other than the specified one V600 A22 B Using any AC adaptor other than t
94. ressed communications with the Data Carrier will commence For details on button commands refer to Section 3 Commands elnterface Connector This is a USB interface with an A series plug based on USB 1 1 eAntenna To communicate with the Data Carrier move the antenna head closer to it RFID System User s Manual 11 o c o c o o E o o 4 o o c 9 pe o c gt LL xo c o oO E z Section 1 Product Overview V600 CH1D V2 D Antenna A Operation indicator LED a Activate switch j Reset button O AC Adaptor connection jack Serial interface connector RFID System User s Manual Operation Indicator LED Display Meaning A command has been received from the host device C Communications with the Data Carrier have completed normally Lit green e When the power is turned ON after initialization of the Hand held Reader Writer is completed e When the power is turned ON and the reset button is pressed for two seconds or more initialization stand by mode Flashing green Communications with the Data Carrier are in progress A communications error with the Data Carrier has occurred A CPU error has occurred Lit red A Data Carrier non existent error has occurred A communications error with the host device has occurred Flashing red t After
95. rite count check will be 3 bytes performed tv Set the start address to between OH and 5H or between 8H and DH If the start address is set i between 6H and 7H or between EH and FH an address error error code 7A hexadecimal will be returned as the end code CHECK For details on command format refer to REF OVERWRITE COUNT CONTROL MDS Q CHECK ICA p 93 RFID System 112 User s Manual Section 4 Functions Using the OVERWRITE COUNT Command Example When the three bytes from address 0010H are used as the overwrite count area 1 The overwrite count initial value of 2 Enter the overwrite count of 5 100 000 times is written in the control MDS1001005 area A total of 5 times will be decremented from WTH10010 100 000 0010 01H 0010 01H 0011 86H 0011 86H 0012 AOH 0012 9BH 77 9 3 The accumulated count is 100 000 times z When MDS1001000 is executed it will be MD76 overwrite count exceeded oc 0 S 0010 00H 9 0011 00H zi 0012 00H e RFID System Users Manual 113 Section 4 Functions Memory Check Function in Data Carrier A memory check can be made using the DATA CHECK command MDC K A CRC Cyclic Redundancy Check code calculation overwrite and com
96. riter and host device Command code Command name Function Page TS TEST Confirms the communications status between the Hand held Reader Writer and host device The data sent from the host device is returned p 95 as is VS VERSION READ Reads the Hand held Reader Writer s model information software ver 95 sion and software creation date P Controller Control Commands These commands are used to reset the Controller or set serial communications Command code Command name Function Page XZ ABORT Resets the Controller p 96 TR COMMUNICA Sets communications parameters for communications with the host TIONS CONDI device p 97 TIONS SETTING FN BASIC FUNC Sets the Specify Auto Command OFF function and Specify Normal 98 TIONS SETTING Operation Output function P UL SET INFORMA Reads the settings data for the Hand held Reader Writer 99 TION READ P RFID System User s Manual ewo asuodsay pue puewwoy 53 Section 3 Commands Communications Commands Details of communications commands used to communicate with the Data Carrier are provided here READ RD This command reads data from the Data Carrier If the Data Carrier is not in the communications area an error response end code 72 Data Carrier non existent will be returned Processing area number 1 Proc essing area Command Data number Read area Number of bytes code Setting setting start address toread Te
97. rives Sy IDE ATA ATAPI controllers Infrared devices Keyboards A Mice and other pointing devices B9 Network adapters 2 Other devices Q PCMCIA adapters orts COM amp LPT Sound video and C23 Storage volumes System devices Universal Serial Bus controllers Communications with the Hand held Reader Writer can be performed with the COM number displayed in parentheses after OMRON RFID USB COM RFID System User s Manual suonesedaig suoneorunuiuo qnH2 009A 27 V600 CHUD Communications Preparations Section 2 Communications Preparations Windows XP 1 Turn ON the power to the personal computer and start Windows XP wv 2 Connect the Hand held Reader Writer to the personal computer For details on connection methods refer to V600 CHUD Communications Preparations e x CHECK ay P22 Wait for the following window to be displayed wv 3 When the following window is displayed select Install from a list or specific location Advanced and click the Next Button Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for V600 CHUD If your hardware came with an installation CD lt lt or floppy disk insert it now What do you want the wizard to do install the software automatically Recommended Click Next to continue Cancel RFID System User s Manual Section 2 Communications Preparations 4
98. rminator S 2 1 1 4 2 2 E E o o Processing area number 2 o e Proc 2 essing T area Number of 9 Command Data number Read area bytes Data Read area Number of bytes c code setting setting start address toread setting start address toread Terminator 2 E E o o Area 1 setting Area 2 setting Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Read area start address Specifies the start address of the area to be read from the Data Carrier in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of bytes to read Specifies the number of bytes to be read from the Data Carrier in 2 digit hexadecimal code The maximum number of bytes that can be read at one time is 256 bytes as follows ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 00h to FFh 00 256 bytes When multiple processing areas are used set so that the total number of bytes from all areas to be read is within 256 bytes as follows Area 1 bytes Area N bytes l
99. s for read data A ASCII H Hexadecimal code Processing area number Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters o o c E E o o o c 2 pz G 2 c 3 E E o o Response Command code End code Read data Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List jl 2 p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual Section 3 Commands EXPANSION BATCH WRITE wt This command writes up to 2 Kbytes of data to the Data Carrier in a batch If the Data Carrier is not in communications range an error response end code 72 Data Carrier non existent will be returned Processing area Command Data number Write area code Setting setting start address Wri
100. s industrial waste and never disassemble apply pressure that would deform heat to higher than 100 C or incinerate SRAM Data Carriers gt O RFID System User s Manual Introduction Precautions for Safe Use Observe the following precautions to ensure safe use of the product 1 Do not use the product in environments with flammable explosive or corrosive gasses 2 Do not attempt to disassemble repair or modify the product 3 The USB driver must be installed in the personal computer before connecting the V600 CHUD to a personal computer 4 Do not subject cables to excessive loads 5 Observe all warnings and precautions given in the body of this manual 6 Discontinue usage and turn OFF the power supply immediately if you notice any unusual odors if the product is abnormally hot or if the product starts smoking 7 When disposing of the product treat it as industrial waste Precautions for Safe Use Inf edd Precautions for Correct Use Always observe the following precautions to prevent operation failures malfunctions and adverse effects on performance and equipment 1 Installation Environment Install the product in the following locations e Locations not subject to corrosive gas dust metallic powder or salt e Locations within the specified operating temperature range e Locations not subject to rapid changes in temperature with no condensation e Locations within the specifie
101. setting setting start address read bytes Terminator 2 1 1 4 2 2 Processing Area Number 2 E P Command Data DOT Read area Number of Data Read area Number of E code setting setting start address read bytes setting start address read bytes Terminator E 8 pou pem epe cal ewan meee o a 2 41 1 4 2 1 4 2 2 5 S Area 1 setting Area 2 setting EJ Data setting Sets the code format used to send responses for read data A ASCII Oo H Hexadecimal code o When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 2 digit hexadecimal The maximum number of bytes that can be read at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 00h to FFh 00 256 bytes When multiple processing areas are used set so that the total number of bytes to be read for all areas is within 256
102. st Meo dA do 1 Hand held Reader Write Frame 1 Response 1 Response 2 Response n 1 Response n RFID System User s Manual spueuiuo suoneoiunuiuo2 3IIT SETS 73 Section 3 Commands EXPANSION DIVIDED WRITE XW Divides and writes up to 2 Kbytes of data If the Data Carrier is not in communications range an error response end code 72 Data Carrier non existent will be returned The host device cannot send commands to the Hand held Reader Writer until all the responses have been received Frame 1 Processing Command Data amber Write area code setting setting start address Write data Terminator 2 1 1 4 n 1or2 Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code Processing area number Always 1 setting Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh Write data Indicates the data to be written to the Data Carrier Data can be between 0 and 257 characters Terminator Indicates the end of the frame CR Succeeding frame CR No succeeding frame o o c E E o o o c 2 pz G 2 c 3 E E o o Frames 2 to N Write data Terminator x x x x x x x x CR n 1or2 Write data Indicates the data to be written to the Data Carrier Data can be between 0 and 265 characters Terminator Indicates the end of the fr
103. t 256 bytes RFID System User s Manual Section 3 Commands Response Processing Area Number 1 Command code End code Read data Terminator LIICICICICIEREREIERC 2 2 n 2 Processing Area Number 2 Command Read data Read data code End code Area 1 Area 2 Terminator Area 1 setting Area 2 setting End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List il 2 p 101 Read data Specifies the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 spuewwoy suoneoiunuluo2 RFID System User s Manual 55 Section 3 Commands WRITE WT This command writes data to the Data Carrier If the Data Carrier is not in the communications area an error response end code 72 Data Carrier non existent will be returned Processing Area Number 1 Processing Command Data numba Write area code setting Setting start address Write data Terminator Processing Area Number 2 Processing Command Data jare Write area Number of Data Write area Number of code setting setting start address write bytes Write data setting start address write bytes Write data Terminator Area 1 setting Area 2 setting Data setting Sets the code format used to send responses for read data A ASC
104. ta bytes Transmission Time 8000 7000 6000 5000 4000 Read 3000 en J 2000 1000 o c S 7 c o E a Uv c 0 c o 2 E o o 2 o Transmission time ms 0 0 256 512 768 1024 1280 1536 1792 2048 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 1 5N 36 7 Write T 3 5N 51 2 N Number of processing data RFID System 8 User s Manual Section 6 Appendices eEEPROM Data Carrier Reference TAT 2000 1500 Write 1000 Reed 500 Transmission time ms 0 32 64 96 128 160 192 224 256 Number of processing data bytes eTransmission Time 2000 1500 Write 1000 RER 500 Transmission time ms 0 32 64 96 128 160 192 224 256 Number of processing data bytes Calculation Method Operation Transmission time ms Read T 3 6N 53 7 Write T 7 3N 90 3 N Number of processing suoisueuiig pue suoneoyioeds RFID System Users Manual 129 Section 6 Appendices eFe RAM Data Carrier Reference TAT 8000 7000 6000 Write 5000 DEN 4000 Read 3000 gt s 2000 1000 Transmission time ms 0 0 256 512 768 1024 1280 1536 1792 20
105. te data Terminator Data setting Specifies the code format used to send write data to the Data Carrier A ASCII H Hexadecimal code Processing area number Always 1 setting Write area start address Specifies the start address of the area to be written to in 4 digit hexadecimal Setting range 0000h to 1FFFh Write data Indicates the data to be written to the Data Carrier The maximum number of bytes that can be written at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters Response Command code Endcode Terminator 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List 1 zi p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 81 Section 3 Commands EXPANSION BATCH AUTO READ ar This command reads up to 2 Kbytes of data from the Data Carrier in a batch when the Hand held Reader Writer moves close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Command pata number Read area Number of code setting setting start address read bytes Terminator Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code Processing area n
106. the EEPROM overwrite count has been exceeded when the specified number of overwrites is subtracted from the specified overwrite count control area data Processing area Command Mode Decrement code setting setting Area start address count Terminator Mode setting Always S Processing area number Always 1 setting Area start address Specifies the start address of the overwrite count control area in 4 digit hexadecimal 9 Setting range 0000h to 1FFDh 3 Decrement count Specifies the number of refresh operations in 2 digit hexadecimal 3 Setting range 00h to FFh 00 Performs overwrite count check only o m For details refer to Data Carrier Service Life Detection o zi p 111 a Qo o 3 t7 Set the start address between OH and 5H or between 8H and DH If the start address is set 3 E A between ILILI6H and 7H or between LILILIEH and FH an address error error code 7A HEX will be a returned in the end code Oo CHECK Command code End code Terminator eetere heen 2 2 2 End code Indicates the execution result for the command 00 Normal completion 76 Data error warning For details on end codes refer to End code List il p 101 V For details on controlling the overwrite count refer to Data Carrier Service L
107. the same address for the start and end bz addresses a 0000 3 Settings when the End Address is Greater than the Final Address in the Data Carrier End address 07FFH 07FF The Data Carrier memory area is allocated from address 0000H to 07FFH Therefore the addresses up to 07FFH will be write protected a 3 Write protected area 0000 vd 0006 4 Settings when the Start Address is Greater than the al End address End Address O7FF De Start address Start address gt End address m The area between 0006H and the end address and the area between the start address and 07FFH are write protected Canceling Write Protection To cancel write protection turn OFF the most significant bit of address 0002H The write protection will be cancelled and the start and end addresses that are set for 0002H to 0005H will be ignored RFID System 110 User s Manual Section 4 Functions Data Carrier Service Life Detection The methods used to detect the service life of the Data Carrier depend on the memory type SRAM or EEPROM For SRAM a battery life check is performed and for EEPROM the number of overwrites is monitored SRAM Data Carriers with Built in Battery Checking If the Battery is Low Built in Battery Not Including V600 D2KR16 1 A battery low check for the Data Carrier can only be performed when special access is made The battery low check is performed by running a fixed current through the internal circu
108. this document to another please copy or transmit it in its entirety RFID System User s Manual Introduction Meanings of Signal Words The following signal words are used in this manual Indicates a potentially hazardous situation which if not avoided will result in minor or moderate VAN Wei Nem injury or may result in serious injury or death Additionally there may be significant property damage A Indicates a potentially hazardous situation which if not avoided may result in minor or moderate CAUTION injury or in property damage Meanings of Alert Symbols SpJoM euBis jo sHhulueayy Tenet The following alert symbols are used in this manual Indicates the possibility of explosion under specific conditions lA S Indicates general prohibitions for which there is no specified symbol Alert Statements in This Manual The following alert statements apply to the products in this manual Each alert statement also appears at the locations needed in this manual to attract your attention This product is not designed to be used either directly or indirectly in applications that detect human presence for the purpose of maintaining safety Do not use this product as a sensing device for protecting human lives A lithium battery is built into SRAM Data Carriers and may occasionally combust explode or burn if not treated properly Dispose of SRAM Data Carriers a
109. ting range 1 to 9 A A 10 Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of write bytes When multiple processing areas are used specifies the number of bytes to be written to the Data Carrier in 2 digit hexadecimal The maximum number of bytes that can be written at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 01h to FFh When multiple processing areas are used set so that the total number of bytes to be written for all areas is within 256 bytes as follows Area 1 bytes Area N bytes lt 256 bytes Write data Indicates the data to be written to the Data Carrier The characters in ASCII indicate the number of write bytes and the characters in hexadecimal code indicate the number of write bytes x 2 RFID System User s Manual Response Command code Endcode Terminator 2 2 2 End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List UA p 101 RFID System User s Manual spuewwoy suoneoiunuluo2 69 Section 3 Commands COP
110. umber Always 1 setting Read area start address Specifies the start address of the area in the Data Carrier to be read from in 4 digit hexadecimal code Setting range 0000h to 1FFFh Number of read bytes Specifies the number of bytes to be read from the Data Carrier in 4 digit hexadecimal The maximum number of bytes that can be read at one time is 2 048 bytes Setting range 0001h to 0800h ASCII 2 048 bytes 2 048 characters Hexadecimal code 2 048 bytes 4 096 characters o o c E E o o o c 2 pz G 2 c 3 E E o o Response Command code End code Read data Terminator End code Indicates the execution result for the command The end code 00 indicates normal completion For details on end codes refer to End code List 1 zi p 101 Read data Indicates the data read from the Data Carrier The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2 RFID System User s Manual Section 3 Commands EXPANSION BATCH AUTO WRITE aw This command writes up to 2 Kbytes of data to the Data Carrier in a batch when the Hand held Reader Writer moves close to the Data Carrier The Hand held Reader Writer responds when communications between the Hand held Reader Writer and Data Carrier have ended Processing Command Data number Write area code setting setting start address Write data Terminator
111. utions and application advice z CHECK z Indicates page numbers containing relevant information enuen si peaH 01 MOH SSmi e Indicates reference to helpful information and explanations for difficult terminology RFID System User s Manual o W jenuey siy peay o1 MOH RFID System User s Manual Introduction Table of Contents 8 Meanings of Signal Words 3 S Meanings of Alert Symbols 3 a Alert Statements in This Manual 3 e Precautions for Safe Use 4 9 Precautions for Correct Use 4 How to Read this Manual 5 z Table of Contents 7 Section 1 Product Overview 9 Features 10 Names and Functions of Components 11 System Configuration 14 Operation Flowchart 17 Section 2 Communications Preparations 21 V600 CHUD Communications Preparations 22 V600 CH1D V2 Communications Preparation 36 V600 CH1D PSI Communications Preparation 39 Communications Test 42 Section 3 Commands 45 Communications with the Data Carrier 46 Command and Response Format 50 Communications Commands 54 Communications Subcommands 94 Host Commands 95 Controller Control Commands 96 Other Commands 100 End code List 101 RFID System User s Manual 7 Table of Contents Iud Section 4 Functions 103 Hand held Reader Writer Functions 104 Data Carrier 106 Section 5 Troubleshooting 117 Error Tables 118 Troubleshooting Flowchart 119 Section 6 Appendices 121 Specifications and Dimensions 122 Data Carrie
112. write bytes Write data setting start address write bytes Write data Terminator 2 1 1 4 2 n 1 4 2 n 2 l l l Area 1 setting Area 2 setting Data setting Sets the code format used to send responses for read data A ASCII H Hexadecimal code When multiple processing areas are used ASCII and hexadecimal code can be specified at the same time within a single command frame o o c E E o o o c 2 pz G 2 c 3 E E o o Processing area number Specifies the processing area number setting Setting range 1 to 9 A A 10 Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4 digit hexadecimal code Setting range 0000h to 1FFFh When multiple processing areas are used specify the areas in order starting from the smallest address The same area cannot be specified twice Number of write bytes When multiple processing areas are used specifies the number of bytes to be written to the Data Carrier in 2 digit hexadecimal The maximum number of bytes that can be written at one time is 256 bytes ASCII 256 bytes 256 characters Hexadecimal code 256 bytes 512 characters Setting range 01h to FFh When multiple processing areas are used set so that the total number of bytes to be written for all areas is within 256 bytes as follows Area 1 bytes Area N bytes lt 256 bytes Write data Indicates the data to be writt
113. written to addresses 0013H and 0014H 0010 12H 0011 34H 0010 12H 0012 56H 0011 34H 0013 0012 56H 0014 0013 5CH 0014 D6H RFID System 4 User s Manual 3 Execute MDC1001005 comparison transaction The normal response MDOO will be returned if the data coincides 0010 0011 0012 0013 0014 12H 34H 56H 5CH D6H If the data error occurs MD76 a data error warning will be returned 0010 0011 0012 0013 0014 Data error RFID System User s Manual Joe ejeg 115 b o fo o G a 116 MEMO RFID System User s Manual Section 5 Troubleshooting 44 Error Tables Fatal Errors Operation Stops Non fatal Errors Operation Continues 4 Troubleshooting Flowchart 118 118 118 119 RFID System User s Manual 117 Error Tables 118 Section 5 Troubleshooting Error Tables If an error occurs in the Hand held Reader Writer the operation indicator lights or flashes red to notify the type of Fatal Errors Operation Stops If a fatal error occurs the operation indicator will be lit red and all operations of the Hand held Reader Writer will stop until the power is turned OFF and then ON again Name Hardware error Operation indicator Lit red Description Hand held Reader Writer cannot be operated normally Memory error Lit red The contents of the backup memory in the Hand held Reader Writer is cor ru
114. you through the process of installing driver software for your device gt Ask me again later Windows will ask again the next time you plug in your device or log on Don t show this message again for this device Your device will not function until you install driver software Cancel w 4 If the User Account Control Dialog Box is displayed click the Continue Button v 5 If a dialog box appears for searching for software online select the Don t search online Option If this dialog box is not displayed go to the next step wv RFID System User s Manual Section 2 Communications Preparations 6 When the following window is displayed select don t have the disc Show me other options But ton x L Found New Hardware V600 CHUD Insert the disc that came with your V600 CHUD If you have the disc that came with your device insert it now Windows will automatically search the disc for driver software I don t have the disc Show me other options Cancel wv T When the following window is displayed select Browse my computer for driver software advanced Button v e Se jj Found New Hardware V600 CHUD Windows couldn t find driver software for your device gt Check for a solution Windows will check to see if there are steps you can take to get your device working Browse my computer for driver software advanced Locate and install driver software manually Cancel